Dräger X-am® 7000 Portable Multi Gas Detector


Add to my manuals
4 Pages

advertisement

Dräger X-am® 7000 Portable Multi Gas Detector | Manualzz

Dräger X-am® 7000

Portable Multi Gas Detector

Dräger X-am 7000 is the solution for the simultaneous and continuous measurement of up to five gases. It is the ideal companion in a variety of applications where the reliable detection of oxygen, toxic and combustible gases and vapors are necessary.

FLEXIBILITY THROUGH SENSOR VARIETY

The extensive portfolio of over 25 different

DrägerSensors enables the detection of more than 100 gases and vapors. The Dräger X-am

7000 can be equipped with three electrochemical, and two catalytic bead, infrared or photo ionization sensors. During operation, it is also possible with the catalytic-Ex sensor to change the gas being measuring or the measurement range of the sensor. In this way, the instrument can be easily adapted to various applications. DrägerSensors are renowned for their fast response time, minor cross sensitivities, high level of accuracy and long lifetimes.

vapors the Dräger X-am 7000 warns reliable of danger of explosions. It not only responds quickly to combustible gases and vapours, it is also characterised by its high resistance against silicone and hydrogen sulphide contamination. In combination with the high degree of drift stability, this resistance enables an extraordinarily long service life of more than 4 years. This will reduce your operational costs.

ROBUST AND WATERTIGHT

A specially designed rubber boot protects the instrument against damage even from a drop of 1.5 m or 5 ft. In addition to the bulit in dust and water filter, the Dräger X-am 7000 can be submersed in up to 1 m or 3 ft. of water without damage.

INTELLIGENT AND INTERCHANGEABLE

SENSORS

In addition to the electrochemical sensors, the catalytic, infrared and photo ionization sensors are automatically recognized by the instrument upon insertion. All sensors are pre-calibrated, and therefore a reconfiguration of the Dräger X-am 7000 can be done by simply changing the sensor.

No additional service or maintenance is necessary.

POISON RESISTANT EX-SENSOR

Advanced safety in explosive atmospheres: thanks to the high sensitivity of the innovative Ex-sensor to combustible organic

BUILT FOR LONGEVITY

The completely new design of the rechargeable battery pack with intelligent chargingmanagement guarantees full functionality of the instrument over a period of up to 20 hours. An alkaline battery pack is also available. The DrägerSensors used in the

Dräger X-am 7000 have a typical lifetime of over 5 years. If a sensor exchange should become necessary , the modular approach of the instrument allows for this in a few simple steps.

Dräger X-am 7000

Modular, rugged and water-tight complete with an integrated high-performance pump.

02 | DRÄGER X-AM 7000

MULTIPLE ALARMS

Alarm conditions can not be ignored because of the extremely loud multi-tone horn. In addition, the visual alarm can be seen

360°, ensuring that the user notices the warning. By generating an optional life-signal every six seconds, the Dräger X-am 7000 confirms that it is functioning properly.

STRONG INTEGRATED PUMP

The built-in high-performance pump makes it possible to sample gas using a hose up to 45 m/150 ft. long. The operation of the pump is continuously monitored, and the instrument will generate an alarm if the flow of gas reduces.

EASY DETECTION OF LECKAGES

A flexible "gooseneck" probe eases the search for leakages on pipelines, valves, flanges, etc. In the tracking-mode, the instrument generates an increasing or decreasing rate of beeps, depending on the gas concentration detected.

INFORMATION AT ONE GLANCE

The large graphic display and the auto-zoom function during alarms guarantee an easy recognition of the measurement values and symbols displayed for immediate reaction to the situation or hazards. All information is provided in plain text for easy understanding. be saved within the instrument. By doing so, the use of different instrument configurations can be set for that specific application.

During operation, a simple change between these set parameters can be done via the instrument's menu.

DATA MANAGEMENT

An integrated data logger logs up to 3000 sets of values – that equals 100 hours when recording one set per minute. The data can then be transferred to and evaluated on a

PC using an infrared interface together with the Dräger GasVision software package.

INTUITIVE SOFTWARE FUNCTIONS

The software menu within the Dräger X-am

7000 was designed in partnership with our customers making it simple and easy to use.

With the help of Dräger CC-Vision software, up to 5 different detection applications can

DrägerSensors

Space for up to 5 sensors, 3 electrochemical and 2 catalytic bead or infrared sensors or a photo ionization detector (PID).

Robust enclosure

Rugged, water-tight with a standard integrated rubber boot.

Alarm functions

360° visible and > 100 dB multi-tone audible alarm.

Large display

Clearly structured, scratch resistant display with information in plain text.

ORDER INFORMATION

Description

Dräger X-am 7000, basic unit including a calibration adapter, water- and dust-filter

•In order to receive a fully operational unit, a power pack and up to 5 sensors have to be ordered. An optional, integrated pump or data logger can also be included.

Order code

83 17 400

Power supply units

Rechargeable power pack NiMH 4.8 V / 3.0 Ah

Rechargeable power pack NiMH 4.8 V / 6.0 Ah

Alkaline power pack

Alkaline batteries (4 pcs.)

83 17 408

83 17 454

83 17 550

83 17 447

Charging accessories

Charging module

Power supply for up to eight charging modules

Power supply for one charging module

Power supply for up to two charging modules

Power supply for vehicles

Car mounting kit

83 16 487

83 15 805

83 15 635

83 16 994

83 12 645

83 18 169

DRÄGER X-AM 7000 | 03

ORDER INFORMATION

Description

Infrared Sensors

DrägerSensor Smart IR Ex

Measuring range Order code

DrägerSensor Smart IR CO

2

DrägerSensor Smart IR CO

2

HC

Catalytic Bead Sensors

DrägerSensor Smart CatEx PR

DrägerSensor Smart CatEx HC PR

DrägerSensor Smart CatEx FR PR

0 – 100 %LEL

0 – 100 Vol.-% CH

4

0 – 5 Vol.-%

0 – 100 Vol.-%

0 – 100 %LEL

0 – 100 %LEL

0 – 100 Vol.-% CH

4

0 – 100 %LEL

0 – 100 Vol.-% CH

4

68 10 460

68 10 590

68 10 599

68 12 970

68 12 980

68 12 975

PID Sensor

DrägerSensor Smart PID 0 – 2000 ppm 83 19 100

Electrochemical Sensors

DrägerSensor XS 2 CO

DrägerSensor XS EC CO

DrägerSensor XS R CO

DrägerSensor XS EC CO HC

DrägerSensor XS 2 H

2

S

DrägerSensor XS 2 H

2

S SR

DrägerSensor XS EC H

2

S 100

DrägerSensor XS EC H

2

S HC

DrägerSensor XS R H

2

S

DrägerSensor XS 2 O

2

DrägerSensor XS EC O

2

100

DrägerSensor XS EC O

2

LS

DrägerSensor XS R O

2

DrägerSensor XS EC Amine

DrägerSensor XS EC Cl

2

DrägerSensor XS EC ClO

2

DrägerSensor XS EC CO

2

DrägerSensor XS EC COCl

2

DrägerSensor XS EC H

2

DrägerSensor XS EC H

2

HC

DrägerSensor XS EC HCN

DrägerSensor XS EC Hydride

DrägerSensor XS EC NH

3

DrägerSensor XS EC NO

DrägerSensor XS EC NO

2

DrägerSensor XS EC Odorant

DrägerSensor XS EC OV

DrägerSensor XS EC OV-A

DrägerSensor XS EC PH

3

HC

DrägerSensor XS EC SO

2

0 – 2000 ppm

0 – 2000 ppm

0 – 2000 ppm

0 – 10 000 ppm

0 – 100 ppm

0 – 100 ppm

0 – 100 ppm

0 – 1000 ppm

0 – 100 ppm

0 – 25 Vol.-%

0 – 100 Vol.-%

0 – 25 Vol.-%

0 – 25 Vol.-%

0 – 100 ppm

0 – 20 ppm

0 – 20 ppm

0 – 5 Vol.-%

0 – 10 ppm

0 – 2000 ppm

0 – 4 Vol-%

0 – 50 ppm

0 – 20 ppm

0 – 300 ppm

0 – 200 ppm

0 – 50 ppm

0 – 40 ppm

0 – 200 ppm

0 – 100 ppm

0 – 1000 ppm

0 – 100 ppm

Calibration and Communication Accessories

Calibration adapter

Sensor extension cable for the calibration with vapors

Dräger X-am 7000 E-Cal Module

Dräger Bump Test Station for Dräger X-am 7000

Complete with one test gas cylinder 58 L (gas and concentration variable)

Dräger Bump Test Station for Dräger X-am 7000, not including gas cylinder

Printer Set for Dräger Bump Test Station Dräger X-am 7000

Consisting of: Dräger Bump Test Station, Dräger Mobile Printer, single charger, rechargeable NiMH batteries, USB connection cable, positioning aid, Dräger CC-Vision

(not including gas cylinder)

83 17 656

83 17 970

83 17 705

83 19 072

83 18 909

83 21 009

Printer Set for Dräger Bump Test Station Dräger X-am 7000 (same contents as 83 21 009), 83 21 020

Complete with one test gas cylinder 58L (gas and concentration variable)

Dräger GasVision 83 14 034

Dräger CC-Vision Freeware

68 09 175

68 08 582

68 09 185

68 11 365

68 09 150

68 09 135

68 09 145

68 09 125

68 09 155

68 09 200

68 09 115

68 09 522

68 09 535

68 09 160

68 10 365

68 09 105

68 10 258

68 09 120

68 10 370

68 10 575

68 09 110

68 09 180

68 10 260

68 10 375

68 09 550

68 09 130

68 10 262

68 09 545

68 09 165

68 11 360

Dräger X-am 7000:

Leak search made easy through the generation of a tracking sound.

Dräger X-am 7000:

High-performance pump simplifies confined space entry.

04 | DRÄGER X-AM 7000

TEC HNICAL DATA

Dimensions (W x H x D)

Weight

Ambient conditions

Ingress protection

Battery life

Alarms

Charging time

Pump mode

Approvals

150 x 140 x 75 mm; 5.9 x 5.6 x 3 in.

Instrument

Rechargeable battery

Temperature

Pressure

Humidity

IP 67

NiMH (4.8 V / 3.0 Ah)

-20 to +55 °C, short-term -40 to +60 °C

-5 to +105 °F, short-term -40 to +130 °F

700 to 1300 hPa

10 to 95 % r.h.

NiMH (4.8 V / 6.0 Ah)

Alkaline

> 9 hours

> 20 hours

> 20 hours

Visual 360° flashing LEDs, audible alarm (> 100 dB at 30 cm or 1 ft.)

3.5 to 7 hours, depending on battery type

Maximum hose length of 45 m; 150 ft.

ATEX

600 g; 21 oz.

490 g; 17 oz. (3.0 Ah)

730 g; 26 oz. (6.0 Ah)

MED

UL

CSA

II 2G Ex d ia IIC T4 Gb

-20 ≤ Ta ≤ +60 °C (NiMH)

-20 ≤ Ta ≤ +40 °C (Alkaline)

I M2 Ex d ia I Mb

BVS 03 ATEX E 371 X

Measurement performance certificate according to:

EN 50271:2001

EN 60079-29-1 (for the CatEx sensors from methane to nonane and infrared sensors)

EN 45544-1 + 2 (CO, H

2

S, CO

2

)

EN 50101 (O

2

)

Marine Equipment Directive 96/98/EC

Class I, Div 1, Group A, B, C, D Temp. code T4

-20 ≤ Ta ≤ +60 °C (NiMH)

-20 ≤ Ta ≤ +40 °C (Alkaline)

Class I, Div 1, Group A, B, C, D Temp. code T4

-20 ≤ Ta ≤ +60 °C (NiMH)

-20 ≤ Ta ≤ +40 °C (Alkaline)

IECEx

CE-mark

Ex d ia IIC T4 Gb

-20 ≤ Ta ≤ +60 °C (NiMH)

-20 ≤ Ta ≤ +40 °C (Alkaline) Ex d ia I Mb

Electromagnetic compatibility (directive 2004/108/EG)

CORPOR ATE HE ADQUARTERS

Drägerwerk AG & Co. KGaA

Moislinger Allee 53–55

23558 Lübeck, Germany www.draeger.com

AUS TR ALIA

Draeger Safety Pacific Pty. Ltd.

Axxess Corporate Park

Unit 99, 45 Gilby Road

Mt. Waverley Vic 3149

Tel +61 3 92 65 50 00

Fax +61 3 92 65 50 95

CANADA

Draeger Safety Canada Ltd.

7555 Danbro Crescent

Mississauga, Ontario L5N 6P9

Tel +1 905 821 8988

Fax +1 905 821 2565

P. R. CHINA

Draeger Safety Equipment

(China) Co., Ltd.

A22 Yu An Rd, B Area,

Tianzhu Airport Industrial Zone,

Shunyi District, Beijing 101300

Tel +86 10 80 49 80 00

Fax +86 10 80 49 80 05

NETHERL ANDS

Dräger Safety Nederland B.V.

Edisonstraat 53

2700 AH Zoetermeer

Tel +31 79 344 46 66

Fax +31 79 344 47 90

FR ANCE

Dräger Safety France SAS

3c route de la Fédération,

BP 80141

67025 Strasbourg Cedex 1

Tel +33 3 88 40 76 76

Fax +33 3 88 40 76 67

REGION A SIA PACIFIC

Draeger Safety Asia Pte Ltd

67 Ayer Rajah Crescent

#06-03

Singapore 139950

Tel +65 68 72 92 88

Fax +65 65 12 19 08

ME XICO

Draeger Safety S.A. de C.V.

Av. Peñuelas No. 5 Bodega No. 37

Fraccionamiento Industrial

San Pedrito

Querétaro, Qro México

Tel +52 442 246-1113

Fax +52 442 246-1114

REGION CENTRAL

AND SOUTH AMERICA

Dräger Panama S. de R.L.

Complejo Business Park,

V tower, 10th floor

Panama City

Tel +507 377-9100

Fax +507 377-9130 [email protected]

REGION MIDDLE EAST, AFRICA

Dräger Safety AG & Co. KGaA

Branch Office

P.O. Box 505108

Dubai, United Arab Emirates

Tel +971 4 4294 600

Fax +971 4 4294 699 [email protected]

SPAIN

Dräger Safety Hispania S.A.

Calle Xaudaró 5

28034 Madrid

Tel +34 91 728 34 00

Fax +34 91 729 48 99

UNITED KINGDOM

Draeger Safety UK Ltd.

Blyth Riverside

Business Park

Blyth, Northumberland

NE24 4RG

Tel +44 1670 352-891

Fax +44 1670 356-266

USA

Draeger Safety, Inc.

101 Technology Drive

Pittsburgh, PA 15275

Tel +1 412 787 8383

Fax +1 412 787 2207

Manufacturer:

Dräger Safety AG & Co. KGaA

Revalstraße 1

23560 Lübeck, Germany

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement