Chungho IGUASSU D-H-A CHA-500AH User manual
Add to my manuals19 Pages
Chungho IGUASSU D-H-A CHA-500AH is a sleek and slim hybrid product combining an air purifier and humidifier, designed to improve indoor air quality and maintain optimal humidity levels. Equipped with a 4-stage air cleaning system, it effectively removes harmful substances such as fine dust, odor, bacteria, and mold.
The Active Cluster Ion generator releases ions that eliminate germs and viruses by creating oxidative OH radicals, enhancing the air purification process. The innovative humidification system uses a rotating disc to maintain a comfortable humidity level without the need for additional devices.
advertisement
http://eng.chungho.co.kr
Deluxe
·
Humidification
·
Air cleaning
User's Manual
▶ Read instruction manual thoroughly before using product.
▶ Product appearance, specification etc. is subject to change without prior notice if necessary for improving product performance.
▶ Design and color may differ from cover model.
▶ The rated voltage of this product is 220-230V/50Hz only.
Greetings
We greatly appreciate your purchase of ChungHo Nais air purification system “IGUASSU D·H·A”.
IGUASSU D·H·A is designed and programmed in accordance with industrial standards. Applied 4 stages of filter system (Pre-filter, Antibiotic filter, HEPA filter and Deodorization filter) make it possible to remove fine dust as small as 0.3
㎛, formaldehyde and volatile organic compound which are one of the causes of
Sick House Syndrome and ammonia, acetaldehyde etc. Antibiotic filter includes extract from ginkgo leaves.
It refrains mold and germ from increasing. Released Cluster Ion helps to eliminate germs and virus more effectively. Natural humidifying method using rotating disc makes the indoor optical humidity.
Please read the instruction manual thoroughly and keep it for a future reference.
Table of Contents
1. Product features
2. Safety precautions
3. Name of each part
4. Operation and display function
5. Filter function
6. Usage of each button
6-1. Power button
6-2. Speed button
6-3. Timer button
6-4. How to use humidification function
6-5. ACI Button
6-6. Sleep button
6-7. Particle Sensor (Sensitivity control)
7. Maintenance and replacement
7-1. Filter cleaning and replacement
7-2. Filter rservice life
7-3. Water tank cleaning
7-4. Disc tank cleaning
7-5. Particle sensor cleaning
8. Troubleshooting
9. Specification
17
18
19
15
16
14
14
11
11
11
12
12
12
13
14~17
8
9
3
4 ~ 7
10
11~ 13
1. Product features
1
Innovative hybrid product
IGUASSU D·H·A is an innovative hybrid product, which is combined with air purifier and humidifier. Air purifier eliminates pollutant in the air and humidifier helps to keep the humidity at the ideal level.
2
Pure and natural humidification system
Purified air filtered by filtering unit contacts wet surface of rotating disc to maintain pleasant humidity level.
3
Active Cluster lon generator
Active cluster lon- ACL(Active Cluster Lon)generator releases and to the air and they are combined with moisture to form cluster ion. It sticks to harmful substances including germ, virus etc and creates oxidative OH radical to destroy pollutant.
4
Superior air cleaning capacity
4 stages air cleaning system equipped with Pre filter, Antibiotic filter, HEPA filter and
Deodorization filter eliminates fine dust and odor substances and it inhibits microbial growth such as mold, germ and bacteria.
5
Auto operation by detecting the pollution level
It displays the indoor air pollution level detected by particle sensor and enable user to know pollution level easily and “Auto” mode controls the airflow speed automatically in accordance with the air pollution level and conveniently keep pleasant air in the room.
6
Convenience
This is equipped with drawer-type water container and it is very easy to pull out.
7
Safety function
While the unit is working, when disc tank is separated from the body then purifying motor stops working to prevent the accident.
8
Alarm function
Display of Indoor air pollution level detected by particle sensor, no water indicator, alarming when the humidity reaches to the set humidity level etc make easy to control.
9
Sleek and slim design
Sleek and slim design along with convenience matches well in any place.
03
04
2. Safety precautions
Cautions are divided into 2 categories: 'Danger' and 'Caution.'
Danger
Associated with the possibility for serious injury or death .
●
Use the designated power rating.
(Inappropriate voltage may cause a fire or electric shock as well as product failure.)
●
Keep the cord out of heavy traffic areas.
(This can lead overheating to outlet.)
●
Put the cord all the way to the end.
(Unstable connection may cause fire.)
●
To disconnect the unit, be sure to pull by the plug and not the cord.
(Damaged power cord can cause a fire and electric shock.)
●
If the power cord is damaged or pin of power plug is loose, request follow-up service.
(An electric shock and fire may occur.)
●
Do not touch the power plug with wet hands.
(An electric shock may occur.)
●
Be careful not to step on and fall over the cord.
(There is a danger of injury or an electric shock.)
●
Keep the power cord pin clean from dust and water.
(An electric shock of fire may occur.)
2. Safety precautions
Danger
Associated with the possibility for serious injury or death .
●
Do not bend the power cord excessively nor allow it to be damaged by being pressed under heavy objects.
(An electric shock may occur. )
●
Do not place heavy object on the product and give a shock on it.
(Damaged product may cause overheating and fire.)
(If the product is malfunctioning, request follow-up service.)
●
If the product falls down, unplug and request follow-up service.
(This cause fire, electric shock and malfunction.)
●
Do not install the product nearby largely flammable materials(Spray, butane, etc).
Do not sprinkle hair spray or insecticide over the product.
(An explosion and fire may occur.)
●
Do not drink water of water tank. Keep your eyes on kids.
(This may be harmful to the health.)
●
Do not allow you to expose cool air directly for long period of time.
(Body temperature may fall.)
●
If the product is damaged or malfunctioning, do not disassemble, repair, or modify it on your own.
(An electric shock or fire may occur.
In case the product is damaged, request follow-up service.)
●
Stop using in the event of abnormal sound or smell.
(Earthquake, fire and flood or abnormal sound or smell is found, stop using the product and unplug the power cord.)
05
2. Safety precautions
Danger
Associated with the possibility for serious injury or death .
●
Do not place the product in damp place or at the place exposed to rain or snow.
(A fire or electric shock may occur.)
●
Do not put your hand into the product while replacing filter.
(Malfunction and electric shock can be followed.)
06
Caution
Associated with injury, property damage, and performance degradation.
●
This product is for indoor usage only.
●
Do not expose this product under direct sunlight.
(If not, it can cause deformation and discoloration. )
●
Do not install the production in a sloped or unstable position.
(If the unit falls down, water can overflow.)
●
This is for purifying air indoor only.
(Other purpose than this including use as a ventilation system can bring out shortened service life of filter and less air purifying efficiency.)
●
Do not use the product at a place such as kitchen, restaurant, construction site etc. which can be filled with oil, dust, poisonous gas etc.
(Shortened service life of filter and less air purifying efficiency may occur.)
(Malfunction can occur by sensor contamination.)
●
Do not put foreign substance such as pin, coin etc. into air inlet or outlet. Especially, do not allow kids to insert object inside.
(Damage of the product and electric shock can be followed.)
●
Do not block air inlet and outlet with laundry or curtain
(Blocking ventilation holes may rise inside temperatures and it can cause a fire.)
2. Safety precautions
Caution
Associated with injury, property damage, and performance degradation.
●
Fill the water tank with purified water or tap water.
●
Empty the water tank and disc tank in case humidi-
But do not use the hot water over 104F
。
C).
And clean up the water tank and disc tank. fication is not used for a long time or there is possibility of freeze.
(Recommendation : everyday/
(If you keep the water stagnant in the twice a week at least)
(Hot water can cause the damage or water leakage of product.)
(Refer to page 15~16 regarding cleaning.) water tank or disc tank for long periods of time, germ and bacteria may breed inside and it can cause odor.)
(After cleaning up the tanks, dry them in the shade.)
●
Do not give the external shock to the water tank.
It can cause the damage of product.
(The external shock is the reason of the water leakage.)
●
Do not allow kids to hang on or climb on the product.
(Injury may occur.)
●
Do not forget to empty the water tank and disc tank before transportation.
(Water leakage can occur.)
●
Before you clean up the product or replace filter, unplug and wait until the product stops working.
(Damage of product and electric shock may occur.)
●
Do not move the product while in operation.
(Malfunction and fire may occur.)
●
Use the product according to guideline in user’s manual.
(If the product is not used in accordance with introduction in the manual, it can cause injury and electric shock.)
07
3. Names of each part
Pollution Level Display
08
Air Outlet
Display and Controller
Side Cover
Air Inlet
Air Inlet
Air Inlet
Rotating Disc
Handle
Particle Sensor/
Humidification Sensor
Cover
Water Level Display
Water Tank
Disc Tank
4. Operation and display function
1
2
3
4
5
6
7
8
9 10
1
2
3
4
5
6
7
8
9
10
11
Sleep
:
Sleep Mode setting
ACI
:
ACI (Active Cluster Ion) On/Off
No Water
:
Lack of water indicator
Power
:
Power On/Off
Speed setting
:
Fan Speed level Indicator
Humidity setting
:
Humidity Level Indicator
Timer setting
:
Time indicator
Speed
:
Speed level setting
Humidity
:
Humidity level setting
Timer
:
Time setting
Pollution level display lamp
:
Display of indoor dust level
11
09
5. Filter function
10
Side cover
Deodorization filter
HEPA filter
Pre-filter
Antibiotic filter
Pre-filter
Antibiotic filter
Eliminate visible particles to the eye such as dust, lint and pet hair.
Consisted of antibiotic substance against antibacterial, mold etc and removes tick, yellow dust.
HEPA filter
Eliminate fine particles as small as 0.3
㎛ such as bacteria and dust of the potential causes of respiratory problems.
Deodorization filter
Made from activated carbon well known for powerful function removes
ETS, VOCS, ammonia and various gases etc.
ACI
(Active Cluster Ion)
Release Cluster Ion to effectively help to eliminate germs and virus.
6. Usage of each button
※Plug in the power before using the product.
※Initially, product is programmed to operate at level 1.
6-1 Power button
①
Setting of ON/OFF
- Press the button to turn on.
- When connecting to power supply, it operates at level 1.
- Press the button for about 2 seconds to turn off.
6-2 Speed button
①
Press ‘SPEED’ button
•
As you press ‘Speed’ button, Speed is switched as follows
"
Level 1
→
Level 2
→
Level 3
→
Turbo
→
Auto
→
Level 1
".
②
Auto setting
•
Set auto mode by pressing ‘SPEED’ button.
•
In the auto mode, depending on level of particle contamination, fan speed is switched as follows
"
Level 1
→
Level 2
→
Level 3
".
Pollution Level
Speed Level
Blue
Level 1
Green / Purple
Level 2
Red
Level 3
Display
6-3 Timer button
①
Timer button
•
Initial setting is programmed for .
②
Press ‘Timer’ button
•
As you press ‘Timer’ button, timer is switched as follows, “
→
2hrs
→
4hrs
→
8hrs
→
”.
Continuation 2 hrs 4 hrs
8 hrs
Display
11
6. Usage of each button
6-4 How to use humidification function
①
Pour the water into the water tank.
•
Pull the water tank handle on the front.
•
Detach the cap beneath of water tank by turning the cap in reverse.
•
After pouring the tap water or purified water and put the cap back.
※
When filling the tank with water or transporting water tank, be aware not to give a shock to water tank. Damage may cause leakage of water.
※
Do not use hot water temperatures of over 104˚F (40 ˚C). Hot water may cause damage and defect.
②
Insert water tank into the body.
•
Initially, insert the lower part of water tank and then the upper part to the body.
•
If water tank or disc tank are not placed completely, it can cause the leakage of water and malfunctioning.
③
Set the humidity.
•
As you press “Humidity” button, humidity is switched as follows.
“
→ 60% → 50%→ 40% → ”.
•
Air purification with humidification works when ‘Humidity’ is turned on.
※
While air purification with humidification is working, set humidity level is reached,
“Humidity” is blinking and rotating disc stops working.
※
Humidification rate varies depending on indoor temperature and humidity.
6-5 ACI button
•
Active Cluster Ion - ACI (Active Cluster Ion) generator releases cluster ion to the air to destroy germ and virus.
•
ACI display is turned on if the ACI button is pressed.
12
6-6 Sleep button
•
If sleep mode is set, pollution level display is turned off and speed is set at level 1 not to interrupt sleep.
※
While ‘Sleep’ is on, ‘Speed’, ‘Humidity’, ‘Timer’, ‘ACI’ can be adjusted.
※
Press ‘Sleep’ button, ‘Sleep’ is released and level 1 is set while other setting stay same.
6. Usage of each button
6-7 Particle sensor (Sensitivity Control)
• The product is set standard level of sensitivity. If the product operates in red color for more than
2 hours even not in high humidity and yellow dust or if the product operates in blue color for more than 1 hour even in high pollution, particle sensor is needed to clean. (please refer to the page 17.)
If the cleaning is no use, control the sensitivity of particle sensor as below.
① While the product is in operation, press ‘Speed’ and ‘Humidity’ for 2 seconds, particle sensor gets vitalized ringing beep sound. (setting sound: ding ding ding).
② Standard speed is set at level 2.
③ While particle sensor get vitalized as you press ‘Humidity’, the sensor gets dull, and as you press ‘Speed’, the sensor gets sensitive.
Level
H igh dull Dull Standard Sensitive High sensitive
Display
④ If the setting is set and press ‘Speed’ and ‘Humidity’ for 2 seconds, sensitivity is set and then function is released but if no button is applied for 10 seconds, the function is automatically released as sensitivity is set
.
13
7. Maintenance and Replacement
7-1 Filter cleaning and replacement
①
Turn off and unplug the unit.
• If not, electric shock may occur.
②
Pull out the side cover as holding the side of the product.
③ Pull out forward the pre filter as pulling two holders.
• Pre filter needs cleansing work with vacuum cleaner or water once a month.
14
④ Detach antibiotic filter,
HEPA filter and deodorization filter from the main body.
⑤ Replace filters which are over service life period with new ones.
⑥ Put the filters into the filter case in a reverse order. (Front cover – pre filter – antibiotic filter
– HEPA filter- deodorization filter)
※ Refer to the page 10
⑦ Insert pre filter to square-shaped hole
(Top and bottom) and to sides (left and right) properly.
⑧ Insert front cover and plug the power.
Square–shaped hole
7-2 Filter service life
Filter Service life & Cleaning Process
Pre filter
Antibiotic filter
HEPA filter
Deodorization filter
1 month
2 months
12 months
6 months
Reuse after cleaning
Change
Change
Change
※
Service life and period of cleaning can be different depending on circumstances.
7. Maintenance and Replacement
7-3 Water tank cleaning
•
Clean the water tank. (Recommendation : Everyday/ twice a week at least.)
①
As you press the power button for 2 seconds, turn off the power.
②
Detach water tank from the body and throw away water.
③
Pour water into the tank up to 1/3 and put the cap back. Shake it with both hands to clean it up.
※ In case the water tank is very contaminated, adjust 1~2 drops of a neutral detergent. After cleaning it with a neutral detergent, don’t forget to wash it out completely.
※ While cleaning water tank, be careful not to drop it. Damage may cause water leakage.
※ While cleaning, don’t use hot water, it can cause deformation and damage.
④
When cleaning water tank, be sure to use clean water.
※ In case you won’t use humidification function for a long time, be sure to dry it up in the shade after cleansing and assemble it.
15
7. Maintenance and Replacement
7-4 Disc tank cleaning
•
Clean up the disc tank. (Recommendation : Everyday/ twice a week at least.)
①
As you press the power button for 2 seconds, turn off the power.
②
Detach water tank from the body and pull out the disc tank.
③
Detach partition from the disc tank and clean it up.
16
④
Detach rotating disc and clean it up in running water with soft cloth or brush as applying neutral detergent.
※ While cleaning, don’t use hot water, it can cause deformation and damage.
※ Do not dissemble the rotating disc.
⑤
Clean up the disc tank with soft cloth or brush as applying neutral detergent.
※ Lift float-type water level sensor slightly and clean up with cleaning brush.
⑥
Reassemble and use it.
※ In case you don’t use humidification function for a long time, be sure to clean up water tank and disc tank and dry them in the shade.
7. Maintenance and Replacement 7. Maintenance and Replacement
7-5 Particle sensor cleaning
•
Particle sensor is…
Particle sensor detects fine dust going around from carpet, cigarette smoke and blanket etc. and send signal to the controller to indicate how polluted indoor air is. Pollution level is displayed by lamp color.
※ Cleaning work is recommended every month.
①
Plug out the power.
※ Do not touch with wet hands.
②
After taking off the cover of particle sensor/ humidity sensor on the right upper side, eliminate dust with soft brush.
③
After cleaning the lens on the upper left side with wet cotton swab and then, get rid of moisture with dry cotton swab.
※ Be careful not to drop the water inside the particle sensor.
④
After cleaning up, assemble it in reverse.
※While cleaning, beware not to make damage of particle sensor.
17
18
8. Troubleshooting
Symptom
When the display is turned off and the product does not work.
Check Point
Is the power plug inserted properly?
Is power outlet is bad?
Yes
Request follow-up service.
No
Make sure unit is properly plugged in.
Use the proper power outlet.
Fan speed gets weak.
Check condition of the filter and clean/replace if necessary.
Replace filters with new ones and clean up pre filter.
Decreased deodorization.
Product is shacking over.
Check out service life of deodorization filter.
Is designated period over?
Is it installed on uneven place?
Replace deodorization filter with new one.
Install it on flat surface.
Bad smell comes out from air outlet.
Check condition of the filter and clean/replace if necessary.
Replace filters with new ones and clean up pre filter.
Are you using the product where the smell and smoke keep rising?
Continuous smell and smoke can cause a performance degradation.
Request follow-up service.
Is there any dust stick onto lens of particle sensor?
Clean up lens of particle sensor.
Pollution level display lamp does not change its color.
Does the lamp keep lighting red? (Pollution level is high?)
Set the level of detection sensitivity
“dull” or “standard”.
Does display button fades out?
Does the lamp keep lighting blue (pollution level is low?)
Set the level of detection sensitivity
“sensitive” or “standard”.
Is the sleep mode set?
Humidity setting display is flickering.
Is the water tank equipped properly?
After water tank is filled with water, ‘No WATER’ display lamp still is flickering?
Float-type water level sensor is floating on water?
If sleep mode is set, display button gets fading out.
Push the disc tank to the end.
Request follow-up service.
Clean up the disc tank and float-type water level sensor.
Others If you still have a problem, request follow-up service.
8. Troubleshooting 9. Specification
Product name
Model name
Power rating
Power consumption
Air flow
Applicable area
The amount of humidification
Dust collection efficiency
Deodorization efficiency
Noise
Installation
Net weight
Dimension
IGUASSU D·H·A
CHA-500AH
Refer to the front page
Air purification : 48 W / Humidification : 58 W
5.5
㎥ /min
39
㎡
450
㎖/hr
90.2 % (Fine dust 0.3
㎛)
95 %
Less than 49.5 dB
Indoor
11 kg
241 W x 468 D x 618 H(
㎜)
19
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project