American Standard Platinum ZM, XM, Gold XI, XM, Silver SI+, SI, XI, Platinum ZM, XM, Gold XM, Silver SI+, SI, Triumph 4YCZ6, 4YCY4, 4YCX3, 4YCC3, Platinum ZM, XM, Gold ZM, Silver SI+, SI, Heritage 4WCZ6, 4WCY4, 4WCX3, 4WCC3, Platinum ZV, SV Quick Reference Guide
Below you will find brief product information for Air conditioner Platinum ZM, Air conditioner Platinum XM, Air conditioner Gold XI, Air conditioner Gold XM, Air conditioner Silver SI+, Air conditioner Silver SI, Air conditioner Silver XI, Gas/Electric System Platinum ZM, Gas/Electric System Platinum XM, Gas/Electric System Gold XM, Gas/Electric System Silver SI+, Gas/Electric System Silver SI, Heat Pump Platinum ZM, Heat Pump Platinum XM, Heat Pump Gold ZM, Heat Pump Silver SI+, Heat Pump Silver SI, Furnace Platinum ZV, Furnace Gold ZM, Furnace Gold XI, Furnace Silver ZI, Furnace Silver SI, Furnace Platinum SV, Furnace Gold SV, Furnace Gold SM, Furnace Silver SI+, Furnace Silver XI, Oil Furnace THV1, Air Handler Series 7 TAM7, Air Handler Series 8 TAM8, Air Handler Series 4 TAM4, Air Handler Series 5 GAM5, Air Handler Series 2 GAF2, Air Handler Series 2 GAT2, Air Handler 4TEE3F, Air Handler 4TEE3C, Air Handler 4TEC, Air Handler TWE, Heat Pump Heritage 4WCZ6, Heat Pump Heritage 4WCY4, Heat Pump Heritage 4WCX3, Heat Pump Heritage 4WCC3, Gas/Electric System Triumph 4YCZ6, Gas/Electric System Triumph 4YCY4, Gas/Electric System 4YCX3, Gas/Electric System 4YCC3, Air Conditioner Allegiance 4TCY4, Air Conditioner Allegiance 4TCX3, Air Conditioner 4TCC3, Air Cleaner AccuClean AFD145. This document is a guide for information on the products and their features.
Advertisement
Advertisement
Quick Reference Guide July 2012 from pr by intro friendly be able produc differen best. T to upse as com if you’d like a product NamiNg system that’s clear, coNcise aNd effective, if you’d like a product NamiNg system that’s clear, coNcise aNd effective, SERIES American Standard Platinum Series™ The greatest number of features and the best possible performance. American Standard Gold Series™ The best blend of performance, features and value. The na that be americ Many u other m and oth the nex American Standard Silver Series The most cost-effective way to ™ American Standard Heating & Air American Standard Heating & Air enjoy comfort and reliability. Conditioning Conditioning is pleased to introduce a new is pleased to introduce a new identification system that will help product identification system product that will help make your sales process more convenient, make your sales process more convenient, and help customers better understand and helpthe customers better understand the efficiency = Highest features and benefits of their products. features and benefits of their products. EffIcIEncy Z X = Mid-range efficiency New Names for the Quality, trust New Names for the Quality, trust aNd reliability you’ve always kNowN. S = Standard efficiency aNd reliability you’ve always kNowN. comfoRt V = Variable-speed motor m = Two-stage or multi-stage motor I = Single-stage motor Qua l ity, com f o rt aNd p e r f o r m aN Based on feedback from dealers and on feedback from dealers and distributors across the country,Based American With this new system, it’s easy to identify the produc distributors Standard Heating & Air Conditioning willacross the country, American And it’s easy to understand what every product soon be updating their namingStandard structure Heating & Air Conditioning will american standard heating & air conditioning, as comfortable as it is reliable. to remove SEER and AFUE designations soon be updating their naming structure from product names. In doingto so,remove and SEER and AFUE designations PRoDUct nAmE foRmERLy KnoWn AS PRoD by introducing in its place a consumerfrom product names. In doing so, and Gas/ElEc Platinum ZM Air Conditioner Allegiance® 20 Air Conditioner With this new system, it’s easy to identify the products youtiered know andsystem, trust. friendly naming you will by introducing in its place a consumerable toat sellaon the true benefits of the And it’s easy to understand what every product be offers glance. Platinum Z Platinum XM Air Conditioner Allegiance® 16 Air Conditioner friendly tiered naming system, you will product, while giving customers clear System be able to sell on the true benefits of the Gold XI Air Conditioner Allegiance® 15 Air Conditioner differentiation between good, better and SERIES DUct nAmE foRmERLy KnoWn AS PRoDUct nAmE foRmERLy KnoWn AS clear product, while giving customers Gold XM G best. This also provides new opportunities American Standard Platinum Series™ The greatest number of Gold SI Air Conditioner Allegiance® 13 Air Conditioner ® differentiation Gas/ElEctric to upsell by grouping components together between good, better and ZM Air Conditioner 20 Air Conditioner SERIES features and Allegiance the best possible performance. Silver SI+ best. This also provides new opportunities as complete packages. Silver XI Air Conditioner American Standard 14 Air Conditioner ™ The best ® American Platinum Series™ The greatest of American Standard Gold blend of performance, Platinumnumber ZM Gas/Electric Triumph® 4YCZ6 Gas/Electric System 16 Series Air Standard Conditioner XM Air Conditioner Allegiance to upsell by grouping components together Silver SI G features and value. features and the best possible performance. The naming update is a rolling change System Silver SI Air Conditioner American Standard 13 Air Conditioner ® packages. Air Conditioner Allegiance 15 Air Conditioner that began with the launch ofas thecomplete new ™ The most cost-effective American Standard Silver Series way to American Standard Gold Series™ The best blend of performance, 15-4145-03 AS Name Change Flyer.indd 1 ® 4YCY4 Gas/Electric System Gold XM Gas/Electric System Triumph americanstandardair.com in Q4 2010. Silver SI Air Conditioner N/A enjoy comfort and reliability. ® features and Conditioner value. all ElEc The naming update is a rolling change 13 Air ir Conditioner Allegiance Many updates to literature, badging ® and Silver SI+ Gas/Electric System Triumph 4YCX3 Gas/Electric System that began with the launch of the new ™ Platinum ZM Heat Pump Heritage® 20 Heat Pump American Silver Series The most cost-effective to have been completed, comfoRt otherway materials Platinum Z Air Conditioner EffIcIEncy American StandardStandard 14 Air Conditioner americanstandardair.com in Q4 2010. enjoy comfortVand reliability. motor and others will continueAmerican to occur over System Z = Highest efficiency = Variable-speed Silver SI Gas/Electric System Standard 4YCC3 Gas/Electric Platinum XM Heat Pump Heritage® 16 Heat Pump Many updates to literature, badging and Air Conditioner American Standard 13 Air Conditioner the next few months. System X = Mid-range efficiency m = Two-stage or multi-stage motor ® 15-4145-03 AS Name Change Flyer.indd 1 Air Handler ® 15-4145-03 AS Name Change Flyer.indd 1 American Standard 13 Heat Pump Platinum ZV Furnace Freedom® 95 Comfort-R™ Variable Speed, Modulating Communicating Furnace System Gold ZM Furnace American Standard WCH/ WCK Heat Pump System 11/11/11 2:11 PM americanstandardair.com Freedom® 95 Comfort-R™ Variable Speed Furnace Gold XI Furnace N/A Silver ZI Furnace Freedom® 95 Single-Stage Furnace Silver SI Furnace a/c Only Platinum ZM Air Conditioner Allegiance® 4TCY4 All-In-One Air Conditioner Gold XM Air Conditioner ® Allegiance® 4TCX3 All-In-One Air Conditioner System American Standard 4TCC3 All-In-One Air Conditioner System Silver SI Air Conditioner American Standard TCK All-In-One Air Conditioner System ® Hybrid ® Silver SI+ Silver SI H a/c Only Platinum Z Gold XM A American Standard 90 Furnace Silver SI+ Platinum SV Furnace Freedom® 80 Comfort-R™ Variable Speed Communicating Furnace Silver SI A Gold SV Furnace Freedom® 80 Comfort-R™ Furnace Gold SM Furnace Freedom® 80 Two-Stage Furnace Silver XI Furnace Freedom® 80 High Efficiency Single-Stage Furnace Silver SI+ Furnace Freedom® 80 Single-Stage Furnace Silver SI Furnace American Standard 80 Furnace Platinum XV Oil Furnace Freedom® 80 Comfort-R™ Variable Speed Oil Furnace 11/11/11 2:11 PM Silver SI+ Air Conditioner ® Gold SI He Silver SI Heat Pump americanstandardair.com Silver SI Heat Pump System Heritage 13 Heat Pump ® fURnAcES American Standard 14 Heat Pump on feedback from Heat Pump Based American Standard 13 Heat Pumpdealers ZV Furnaceand distributors Freedom 95 Comfort-R Variable Speed, across ™the country, Modulating Communicating Furnace American Standard Heating & Air Furnace Freedom 95 Comfort-R™ Variable Speed Furnace will soon be updating Conditioning urnace N/A their naming structure to remove urnace Freedom 95 Single-Stage Furnace SEER and AFUE designations from urnace American Standard 90 Furnace product names. In doing so, and by Freedom 80 Comfort-R™ Variable Speed SV Furnaceintroducing in its place a consumerCommunicating Furnace ™ Furnace 80 Comfort-R Furnace friendlyFreedom tiered naming system, 80 Two-Stage Furnace Furnace you will Freedom be able to sell on the true Furnace Freedom 80 High Efficiency Single-Stage benefitsFurnace of the product, while giving differentiation Furnace customers Freedom clear 80 Single-Stage Furnace betweenAmerican good,Standard better80and best. This urnace Furnace ™ Variable Speed XV Oil Furnace Freedom 80 Comfort-R also provides new opportunities Oil Furnace to upsell by grouping components Oil Furnace Freedom 80 Single-Stage Oil Furnace togetherN/A as complete packages. ZV Air Handler The naming update is a rolling XV Air Handler N/A that began with the launch ir Handler change N/A new americanstandardair. Air Handler of the N/A Air Handlercom inN/A Q4 2010. Many updates ZV Air Handler 4TEE Variable Speed Communicating to literature, badging and other Air Handler materials have been completed, and XV Air Handler 4TEE Variable Speed Air Handler others will continue toHandler occur over SV Air Handler 4TFE Variable Speed Air fewAirmonths. ir Handler the next 4TEC Handler PAcKAGED SyStEmS Hybrid Platinum Z System Gold XM H System AccuLink™ Control Platinum ZM Hybrid Comfort Heritage Hybrid™ Comfort System System 4DCZ6 ® Gold XM Hybrid Comfort System Heritage Hybrid™ Comfort System 4DCY4 Silver SI Oil Furnace Freedom® 80 Single-Stage Oil Furnace AccuLink™ Platinum ZV Control N/A Platinum ZV Air Handler N/A AccuLink™ Remote Control N/A Platinum XV Air Handler N/A Gold ZM Control 900 Family 7-day Digital Programmable Comfort Control Gold SI Air Handler N/A Gold XI Air Handler N/A Gold XM Control 800 Family 7-day Digital Programmable Comfort Control Silver SI Air Handler N/A Silver SI+ Platinum ZV Air Handler 4TEE Variable Speed Communicating Air Handler Silver SI C Platinum XV Air Handler 4TEE Variable Speed Air Handler Platinum SV Air Handler 4TFE Variable Speed Air Handler Gold SI Air Handler 4TEC Air Handler Silver SI Air Handler 4TGB/ 4TFB Air Handler Silver XI Control Silver SI+ Control Silver SI Control 600 Family 5/2 Digital Programmable Comfort Control 400 Family Digital Non-Programmable Comfort Control 200 Family Digital Non-Programmable Comfort Control © 2011 American Standard Heating & Air Conditioning All rights reserved 4TGB/ 4TFB Air Handler can Standard Heating & Air Conditioning All rights reserved 15-4145-03 AS Name Change Flyer.indd 2 Pub. No. 15-4145-03 AccuLink™ Gold ZM C contRoLS ® (Phasing out) ® foREfRont™ AIR HAnDLERS ® AIR HAnDLERS Heat Pump Gold SI Heat Pump American Standard 14 Heat Pump ® contRoLS eat Pump Gold XM H ® Silver XI Heat Pump A HigHer StAndArd of Comfort. New Names for the QualGold XM Heat Pump System Heritage 4WCY4 Heat Pump System Heritage 15 Heat Pump ity, trust and reliability Gold SI Heat Pump System Heritage 4WCX3 Heat Pump System Heritage 13 Heatstandard Pump heating & air conditioning, as comfortable as it is reliable. A HigHer StAndArd of Comfort. american you’ve always known. Silver SI+ Heat Pump System American Standard 4WCC3 Heat Pump ® Heritage® 15 Heat Pump ® ®= Standard Sheating efficiency I = Single-stage motor american standard & air conditioning, as comfortable as it System is reliable. 16 Heat Pump XM Heat Pump Heritage Heat Pump Gold XI Heat Pump PAcKAGED SyStEmS ® other materials have been completed, and others will continue to occur over the®next few months. Heritage 4WCZ6 Heat Pump System HEAt PUmPS American Standard Heating & Air Conditioning is pleased to introduce a new product identification system that will help make your sales process more convenient, and help customers EffIcIEncy comfoRt better understand the featuresmotor and S = Standard efficiency I = Single-stage Air Conditioner N/A all ElEctric Z = Highest efficiency V = Variable-speed motor benefitsHeritage of their products. ZM Heat Pump Heat Pump X =20Mid-range efficiency m = Two-stage or multi-stage Platinum ZM Heatmotor Pump AIR conDItIonERS Qual ity, com f o rt a N d p er fo r m a Nc e. sta N da rd ized . Gold XM C Silver XI C Contents • • • • • • • • • • • • This publication is for general reference information only and is not intended for systems equipment / combination selections. Products listed in this book are not always carried in factory/distributor inventory, nor are all products available through all distribution channels. Consult your Distributor for availability and shipping information. Since American Standard Heating & Air Conditioning has a policy of continuous product improvement, it reserves the right to change design and specification without notice. • • • • • • • • • • • • © 2012 American Standard Heating & Air Conditioning All rights reserved Model Nomenclature.................................................................................................. TOC-5 Connected Home Solutions •AccuLink™ Control............................................................................................. CHS-1 •NEXIA™ Accessories......................................................................................... CHS-2 •Remote Sensors................................................................................................. CHS-4 Split System Cooling •Single Phase, 1½-5 Tons (4A7Z0, 4A7A6, 4A7A5)................................................SC-1 •Single Phase, 1½-5 Tons (4A7A3, 4A7M3, 4TTM3)..............................................SC-3 •Single Phase, 1½-5 Tons (4A7B4, 4TTB4, 4A7B3, 4TTB3)...................................SC-5 •Single Phase, 1½-5 Tons (2A7B3, 2TTB3, 2TTM3)...............................................SC-7 •Three Phase, 2½-5 Tons (4A7C3, 4TTA3).............................................................SC-9 •Three Phase, 6-25 Tons, R-410A (TTA)...............................................................SC-11 •ReliaTel™ Controls, 6-25 Tons - Protection/Operation Timings and Features.....SC-15 Split System Heat Pumps •Single Phase, 1½-5 Tons (4A6Z0, 4A6H6, 4A6H5)...............................................SH-1 •Single Phase, 1½-5 Tons (4A6H3, 4A6B4, 4A6B3, 4TWB3).................................SH-3 •R-22 Dry Ship Replacement Heat Pump (2A6B3, 2TWB3)...................................SH-5 •Three Phase, 2½-5 Tons (4A6C3, 4TWA3)............................................................SH-7 •Three Phase, 6-20 Tons, R-410A (TWA)...............................................................SH-9 •ReliaTel™ Controls, 6-20 Tons - Protection/Operation Timings and Features.....SH-12 Air Handlers/Heaters •Multi-position Chart................................................................................................AH-1 •Features and Benefits............................................................................................AH-2 •Series 7 & 8 Variable Speed Multi-Position, 2-5 Tons (TAM7, TAM8).....................AH-3 •Series 4 Multi-Position, Single Phase, 1 ½-5 Tons (TAM4)....................................AH-6 •Series 5 Multi-Position, Single Phase, 1 ½-5 Tons (GAM5)...................................AH-8 •Series 2 Split System, Single Phase, 1 ½-5 Tons (GAF2, GAT2)........................AH-10 •Heaters for Multi-Position.....................................................................................AH-12 •Silver Series Convertible (4FWC, 4FWH)............................................................AH-14 •Silver Series Stud Mount (4FWM).......................................................................AH-15 •Silver Series Furr-Down (4FWD, 4FWF)..............................................................AH-16 •Heaters for Silver Series......................................................................................AH-17 •Variable Speed Convertible, 2½-5 Tons (4TEE3F)..............................................AH-19 •Single Phase, 1½-5 Tons (4TEC).........................................................................AH-21 •Heaters for Split System and Convertible............................................................AH-22 •Single Phase 5-10 Tons, Three Phase 5-25 Tons (TWE).....................................AH-24 Coils •Split System Aluminum Cased Heat Pump and Cooling (4TXC-CC, 4TXC-BC)...................................................................................... COIL-1 •Split System Aluminum Uncased Heat Pump and Cooling (4TXA-BC)....................................................................................................... COIL-2 •Split System Cased Heat Pump and Cooling (4CXC-CC, 4TXF)...................... COIL-3 •Split System Uncased Coil Enclosures & Features........................................... COIL-4 •Silver Series Cased & Uncased Cooling (4FXC, 4FXA).................................... COIL-5 •Silver Series Flat & Horizontal Cooling (4FXFH, 4FXCH)................................. COIL-6 Furnaces •Platinum SV, Gold ZM, Gold XI, Silver SI & Silver ZI Airflow Directions............. FUR-1 •Platinum SV Modulating Communicating Variable Speed (AUHM, ADHM)........ FUR-2 •Gold ZM Two Stage Variable Speed (AUH2, ADH2)........................................... FUR-2 •Silver ZI Single Stage (AUH1, ADH1)................................................................. FUR-3 •Gold XI Single Stage w/ High Efficiency Motor (AUH1-H, ADH1-H)................... FUR-3 •Freedom 90 Single Stage w/ High Efficiency Motor (AUX1-H, ADX1-H)............ FUR-4 •Silver SI Single Stage (AUC1, ADC1)................................................................. FUR-4 •Platinum SV, Gold ZM, Gold XI, Silver SI & Silver ZI Features & Accessories... FUR-5 •Special Use Furnace Accessories...................................................................... FUR-7 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TOC-1 Effective 7/1/12 14-1011-28 Contents Furnaces (continued) • Platinum SV, Gold SV, Gold SM, Silver XI, Silver SI+ & Silver SI Airflow Directions.............................................................................................. FUR-8 •Platinum SV Two Stage Variable Speed (24 Volt) (AUD2-ACV, ADD2-ACV)...... FUR-9 •Gold SV Two Stage Variable Speed (AUD-A-V-V, ADD-A-V-V)........................... FUR-9 •Gold SM Two Stage (AUD2, ADD2).................................................................. FUR-10 •Silver XI Single Stage w/ High Efficiency Motor (AUD1-H, ADD1-H)................ FUR-11 •Silver SI+ Single Stage (AUD1, ADD1)............................................................. FUR-11 •Silver SI Single Stage (AUE1, ADE1)............................................................... FUR-12 •Platinum SV, Gold SV, Gold SM, Silver XI, Silver SI+ & Silver SI Features & Accessories.................................................................................. FUR-13 •Special Use Furnace Accessories.................................................................... FUR-14 •Variable Speed High Efficiency Oil Furnaces (THV1, TLF1, TLR1, TDF1)....... FUR-15 •High Efficiency Oil Furnaces (THV1, TLF1, TLR1, TDF1)................................ FUR-16 Indoor Air Quality •AccuClean™ Whole Home Air Cleaner................................................................IAQ-1 •Perfect Fit™ Media Filters (TFM, TFP).................................................................IAQ-2 •Perfect Fit™ Filter Accessories.............................................................................IAQ-3 •Humidifiers Fan Powered and Bypass..................................................................IAQ-6 •Energy Recovery Ventilator (ERV)........................................................................IAQ-9 Comfort Controls/Zone Sensors •AccuLink™ Platinum ZV Control...................................................................... CCZS-1 •Wired Sensor with Display................................................................................ CCZS-2 •Conventional 24 Volt HVAC System Interface Relay Panel for AccuLink™ Platinum ZV Control..................................................................... CCZS-3 •AccuLink™ Platinum ZV Control Component Overview................................... CCZS-4 •AccuLink™ Zoning Assembly & Zone Expander Panel.................................... CCZS-5 •AccuLink™ Zoning Component Overview........................................................ CCZS-6 •24 Volt Modulating Dampers............................................................................. CCZS-8 •Programmable 7 Day...................................................................................... CCZS-13 •Programmable 5/2 Day................................................................................... CCZS-14 •Non-Programmable......................................................................................... CCZS-15 •Remote Sensors............................................................................................. CCZS-16 •Indoor Fan Delay Relay Kit & Outdoor Thermostat Kit.................................... CCZS-17 •Non-Programmable for ReliaTel™ Units......................................................... CCZS-18 •Programmable for ReliaTel™ Units................................................................. CCZS-18 •Zone Sensor Unit Installation.......................................................................... CCZS-20 •Micro Control Zone Sensors........................................................................... CCZS-21 •Electronic Programmable Zone Sensors for ReliaTel™ Units......................... CCZS-22 •Integrated Comfort™ Systems Sensors for ReliaTel™ Units.......................... CCZS-22 Packaged Cooling •Convertible, 1½-5 Tons (4TCY4, 4TCX3, 4TCC3).................................................PC-1 •Convertible, 1½-5 Tons Features & Accessories...................................................PC-2 •Convertible, 1½-5 Tons Heaters.............................................................................PC-4 •Convertible, 3-10 Tons Features............................................................................PC-5 •Convertible, 3-5 Tons, R-410A (THC-E, TSC-E)....................................................PC-6 •Convertible, 6-10 Tons, R-410A (THC, TSC).........................................................PC-7 •Convertible, 3-10 Tons Model Digit Numbers.........................................................PC-8 •Convertible, 3-10 Tons, R-410A Electric Heaters...................................................PC-9 •Convertible, 6-10 Tons, R-410A Electric Heaters.................................................PC-10 •Convertible, 3-10 Tons Accessories.....................................................................PC-13 •Convertible, 3-10 Tons Zone Sensors/Thermostats.............................................PC-15 •ReliaTel™ Controls (Packaged Unit Protection/Operation Timings & Features)...............................PC-16 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TOC-2 Effective 7/1/12 14-1011-28 Contents Packaged Cooling (continued) •ReliaTel™ Controls (Operation with an Electromechanical Thermostat)...........................................PC-17 •Packaged Cooling with ReliaTel™ Controls, 12½-25 Tons, R-410A (TCD-F/TCH-F)..................................................................................................PC-18 •Packaged Cooling with ReliaTel™ Controls, 12½-25 Tons FIOPS......................PC-20 •Packaged Cooling with ReliaTel™ Controls, 12½-25 Tons Zone Sensors/Thermostats...............................................................................PC-20 •Packaged Cooling with ReliaTel™ Controls, 12½-25 Tons Accessories..............PC-21 •Packaged Cooling with ReliaTel™ Controls, 12½-25 Tons Heaters.....................PC-23 Packaged Heat Pump •Convertible, 2-5 Tons (4WCZ6, 4DCZ6)................................................................PH-1 •Convertible 2-5 Tons (4WCY4, 4DCY4).................................................................PH-2 •Convertible, 2-5 Tons Features & Accessories......................................................PH-3 •Convertible, 1½-5 Tons (4WCX3, 4WCC3)............................................................PH-5 •Convertible, 1½-5 Tons Features & Accessories...................................................PH-6 •Convertible, 1½-5 Tons Heaters.............................................................................PH-8 •Over/Under 2-5 Tons (4WHC3)..............................................................................PH-9 •Convertible, 3-10 Tons Features..........................................................................PH-10 •Convertible, 3-10 Tons (WSC).............................................................................PH-11 •Convertible, 3-10 Tons Model Digit Numbers.......................................................PH-12 •Convertible, 3-5 Tons, Electric Heaters................................................................PH-13 •Convertible, 6-10 Tons Electric Heaters & Zone Sensors....................................PH-14 •Convertible, 3-10 Tons Accessories.....................................................................PH-15 •Packaged Heat Pump with ReliaTel™ Controls, 12½-20 Tons (WCD/WCH).......PH-17 •Packaged Heat Pump with ReliaTel™ Controls, 12½-20 Tons FIOPS & Zone Sensors.....................................................................................PH-18 •Packaged Heat Pump with ReliaTel™ Controls, 12½-20 Tons Accessories........PH-19 •Packaged Heat Pump with ReliaTel™ Controls, 12½-20 Tons Heaters...............PH-20 Packaged Gas/Electric •Convertible, 2-5 Tons (4YCZ6, 4YCY4).................................................................PG-1 •Convertible, 2-5 Tons Features & Accessories......................................................PG-2 •Convertible, 1½-5 Tons (4YCX3)...........................................................................PG-4 •Convertible, 1½-5 Tons (4YCC3)...........................................................................PG-5 •Convertible, 1½-5 Tons Features & Accessories...................................................PG-6 •Convertible, 3-10 Tons Features............................................................................PG-8 •Convertible, 3-5 Tons, 15 SEER, R-410A (YHC-E)................................................PG-9 •Convertible, 3-5 Tons, 13 SEER, R-410A (YSC-E)..............................................PG-10 •Convertible, 17 Plus 6-10 Tons, R-410A (YHC)...................................................PG-11 •Convertible, 6-10 Tons, High Efficiency, R-410A (YHC-E)...................................PG-12 •Convertible, 6-10 Tons, R-410A (YSC-E).............................................................PG-13 •Convertible, 3-10 Tons Model Digit Numbers.......................................................PG-14 •Convertible, 3-10 Tons Accessories.....................................................................PG-15 •Convertible, 3-10 Tons Zone Sensors/Thermostats.............................................PG-17 •Packaged Gas/Electric with ReliaTel™ Controls 12½-25 Tons, R-410A (YCD-F/YCH-F)....................................................................................PG-18 •Packaged Gas/Electric with ReliaTel™ Controls 12½-25 Tons FIOPS................PG-22 •Packaged Gas/Electric with ReliaTel™ Controls 12½-25 Tons Accessories.......PG-23 •Packaged Gas/Electric with ReliaTel™ Controls 12½-25 Tons Zone Sensors/Thermostats...............................................................................PG-24 Factory Installed Options •Commercial Packaged Units 12½-25 Tons...................................................... FIOPS-1 •Accessories..................................................................................................... FIOPS-2 Unit Heaters •Indoor Gas Heating Products................................................................................UH-1 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TOC-3 Effective 7/1/12 14-1011-28 Contents Extended Warranties •Standard Trane Warranty Company...................................................................... WA-1 Accessories/Information •Roof Curbs (BAYCURB050A, BAYCURB051A)............................................... AC/IN-1 •3-25 Ton Packaged Units Roof Curb Compatibility Information........................ AC/IN-2 •Thermal Expansion Valves................................................................................ AC/IN-3 •Equipment Date Identification........................................................................... AC/IN-5 •Refrigerant Line Sets........................................................................................ AC/IN-6 •Refrigerant HFC 410A (R-410A)....................................................................... AC/IN-7 •Refrigerant Piping Information for Allegiance/Heritage 16 & 20 Split Systems.................................................................................................. AC/IN-8 •6-20 Tons Split System..................................................................................... AC/IN-9 •Branch Circuit Wire Sizing Table/Heater De-Rating Chart.............................. AC/IN-11 •Basic Air Conditioning Formulas..................................................................... AC/IN-12 •Low Ambient Accessories, Cooling & Heating Models................................... AC/IN-13 •Wind Shields................................................................................................... AC/IN-14 Geothermal •Water to Air Packaged Units (1GX-2GX, 1GC)...................................................GEO-1 •Water to Water Packaged Units (1GW, 2GW).....................................................GEO-5 •Triple Function Hybrid Water to Air Systems (GY)..............................................GEO-8 •Split Heat Pump Units (1GN-2GN, GE)............................................................GEO-10 •Split Air Handlers (GA)......................................................................................GEO-13 •Coils (GCX).......................................................................................................GEO-13 •Standard Accessories.......................................................................................GEO-16 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TOC-4 Effective 7/1/12 14-1011-28 Model Nomenclature Outdoor Units New Outdoor Units Commercial Condensing Units Cooling and Heat Pump 4 A 7 Z 0 0 3 6 A 1 0 0 0 A A T T A 0 9 0 D 3 H R B 0 Refrigerant Type 2 = R-22 4 = R-410A A, T American Standard Product Type 6, W = Split Heat Pump 7, T = Split Cooling Product Family Z = Leadership - Two Stage A = Allegiance H = Heritage M or B = Basic C = Light Commercial TTA = Split Cooling TWA = Split Heat Pump 090 120 150 180 240 = = = = = 7 1/2 Tons 10 Tons 12 1/2 Tons 15 Tons 20 Tons 090 120 180 240 300 = = = = = 7 1/2 Tons 10 Tons 15 Tons 20 Tons 25 Tons D = Single Compressor (R-410A) E = Dual Compressors (R-410A) F = Dual Manifolded Compressors (R-410A) Family SEER 0 = 20 1 = 11 5 = 15 2 = 12 6 = 16 3 = 13 8 = 18 4 = 14 9 = 19 Split System Connections 1-6 Tons 0 = Brazed 3 = 208 - 230/3/60 4 = 460/3/60 W=575/3/60 0 = No Hail Guard H = Hail Guard Nominal Capacity in 1000's (BTUH) Major Design Change 0 S R T Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60 Secondary Function = = = = Packed Stock, No Options Epoxy Coil ReliaTel™ ReliaTel™ with Epoxy Coil Minor Design Change Service Digit - Not Orderable Minor Design Change Service Digit - Not Orderable AirHandler Handler Air Accessories G A M 2 A 0 A 3 6 S 3 1 S A A Brand A = American Standard G = Good (American Standard Branded) Product Type A = Air Handler Low Static Drive Convertability M = Multi-poise 4-way F = Upflow Front Return, 3-way T = 3-way Product Tier 2 = Good, Entry Level Feature Set 4 = Better, Retail Replacement Mid Effy. 5 = Better, Entry Level High Effy., Multi-Speed 7 = Best, Retail Replacement High Effy., Variable-Speed 8 = Best, Retail Ultimate High Effy., Variable-Speed Major Design Change Single Power Entry Kit No Descriptor 0 = Air Handler / Coil Size (Footprint) A = 17.5 x 21.5 B = 21.0 x 21.5 C = 23.5 x 21.5 Cooling Size: Air Handler or Coil 0-9 = AH Coil - 1000 BTU’s (18, 24, 30, 36, 42, 48, 60) Airflow Type & Capability S = Low Effy PSC, 1-5 - nom. Tonnage (cfm/ton) M = Mid Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton) H = High Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton) V = High Effy Variable, 1-5 - nom. Tonnage (cfm/ton) Power Supply 1 = 208-230/1/60 Major Design Change Minor Design Change System Control Type S = Standard - 24 VAC C = CLII 13.8 VDC Minor Design Change Unit Parts Identifier Service Digit - Not Orderable For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TOC-5 Effective 7/1/12 14-1011-28 Model Nomenclature Air Air Handler HandlersElectric Furnace Residential Air Handler Commercial 4 T E E 3 C 0 1 A 1 0 0 0 A A Refrigerant Type 4 = R-410A D Application TE = Fully Convertible TG = Semi Convertible TF = Front Return Product Family E = Leadership - Variable Speed H = High Efficiency C = Replacement/Retail B = Basic Flow Control 3 = TXV–Non-bleed 060 = 5 Tons 180 = 15 Tons 090 = 7 1/2 Tons 240 = 20 Tons 120 = 10 Tons 300 = 25 Tons 150 = 12 1/2 Tons Feature Indentifier 0 = Standard Unit F = Air-Tite™ C = Communicating Air Handler D = Communicating with Intergated Whole Home Air Cleaner 00 = Packed Stock (No Options), Standard Motor - Electromechanical 03 = 2 speed VFD Standard Motor - Electromechanical Controls 04 = 2 speed VFD Oversized Motor - Electromechanical Controls R3 = SZVAV VFD Standard Motor - ReliaTel Controls™ R4 = SZVAV VFD Oversized Motor - ReliaTel Controls™ Model Number Capacity Distinguisher Major Design Change Power Supply 1 = Single Phase Electrical Connection 0 = Pig Tails B = Circuit Breaker D = Pull Disconnect Future Option - Factory Installed Heater Nominal KW Value Minor Design Change Service Digit - Not Orderable Air Handler/ Minor Design Change Service Digit - Not Orderable Air Air Handler HandlersResidential Residential Air Handler/ ElectricFurnace Furnace Electric Heaters Heaters B A Y H T R 1 4 1 5 B R K A Accessory 4 T E E 3 F 3 6 A 1 0 0 0 A A Heater Power Supply Refrigerant Type 4 = R-410A 1 = Single Phase 3 = Three Phase Application TE = Fully Convertible TG = Semi Convertible TF = Front Return TB = Modular Blower Series/Family 3 = 2/4TEH Models Only Heater KW Electrical Connection Product Family E = Leadership - Variable Speed H = High Efficiency C = Replacement/Retail B = Basic Flow Control 0 = No Flow Control 3 = TXV–Non-bleed 000 = Pig Tails Only BRK = Circuit Breaker PDC = Pull Disconnect RBR = Recessed Breaker-TVF018, TVF024, 14" Deep only RPD = Recessed Pull Disconnect-TVF018, TVF024, 14" Deep only Minor Design Change Feature Indentifier 0 = Standard Unit F = Air-Tite™ D = Intergated Whole Home Air Cleaner C = Communicating Air Handler Nominal Capacity in 1000's (BTUH) Major Design Change Power Supply 1 = Single Phase Electrical Connection 0 = Pig Tails B = Circuit Breaker D = Pull Disconnect Future Option - Factory Installed Heater Nominal KW Value Minor Design Change Service Digit - Not Orderable NOTE: There will be a phase-in of new model numbers for new air handlers over next 2 years. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TOC-6 Effective 7/1/12 14-1011-28 Model Nomenclature Gas Furnaces Furnaces 15 - Digit Gas Furnaces A U D 1 B 0 8 0 A 9 H 3 1 A A A AU AD Furnace Configuration AU = Upflow/Horizontal AD = Downflow/Horizontal Type E = 80% Induced Draft Standard D = 80% Induced Draft Premium C = 90% Condensing Standard X = 90% Condensing Premium H = 95% Condensing Premium Heating Input in 1000’s (BTUH) Number of Heating Stages 1 = Single Stage 2 = Two Stage 3 = Three Stage M = Modulating Cabinet Width A = 14.5" Cabinet Width B = 17.5" Cabinet Width C = 21.0" Cabinet Width D = 24.5" Cabinet Width Heating Input in 1000’s (BTUH) 080 = 80,000 BTUH Major Design Change Service Digit - Not Orderable Voltage 9 = 115 Volts / 60 Hertz / Natural Gas A = 115 Volts / 50 Hertz / Natural Gas C = 115 Volts / Natural Gas with Communicating System Control F = 115 Volts / Natural Gas with Integrated Electronic Filter D = 115 Volts / Natural Gas with Communicating System Control and Integrated Electronic Filter Air Capacity for Cooling Standard PSC Variable Speed 24 = 2 Tons V3 = 3 Tons 36 = 3 Tons V4 = 4 Tons 42 = 3.5 Tons V5 = 5 Tons 45 = 4 Tons 48 = 4 Tons 54 = 5 Tons 60 = 5 Tons 72 = 6 Tons High Efficiency H3 = 3 Tons H4 = 4 Tons H5 = 5 Tons Draft Inducer Speeds 1 = Single Speed 2 = Two Speed V = Variable Speed Minor Design Change Service Digit - Not Orderable For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TOC-7 Effective 7/1/12 14-1011-28 Model Nomenclature Oil Furnaces Oil Furnace Heat Pump/ Cooling Coils Heat Pump/ Cooling Coils 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 T H V 1 M 0 8 7 A 9 3 6 S A A 4 T X C B 0 36 A C 3 H C A A Refrigerant Type 4 = R-410A Series T = Premium (Heat Pump or Convertible Coil) C = Standard (Cooling Only) Coil Design X = Direct Expansion Evaporator Coil Furnace Configuration HV = High Boy Vertical Flue LF = Low Boy Front Flue (vertical) LR = Low Boy Rear Flue DF = Downflow/Horizontal Front Flue Heating Stages Coil Feature C = Cased A Coil A = Uncased A Coil F = Cased Horizontal Flat Coil Cabinet Width M = 22 1/4" Heating Output in 1000’s (BTUH) 087 = 87,000 BTUH Coil Width (Cased/Uncased) A = 14.5" /13.3" B = 17.5" / 16.3" C = 21.0" / 19.8" D = 24.5" / 23.3" H = 10.5" Major Design Change Power Supply 1 = 115 v/1 ph/60hz Refrigerant Line Coupling 0 = Brazed Nominal Capacity Standard Variable Speed 36 = 3 Tons V3 = 3 Tons 48 = 4 Tons V4 = 4 Tons Nominal Capacity in 1000's (BTUH) Major Design Change Efficiency S = 80% + AFUE Minor Design Change Efficiency C = Standard S = Hi Efficiency (derived from 10 SEER products) Service Digit - Not Roderable Refrigerant Control 3 = TXV - Non-Bleed Coil Circuitry H = Heat Pump C = Cooling Airflow Configuration A = Upflow Only U = Upflow / Downflow H = Horizontal Only C = Convertible - Upflow, Downflow, Left or Right Airflow Minor Design Change Service Digit - Not Orderable For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TOC-8 Effective 7/1/12 14-1011-28 Model Nomenclature Heat Pump/ Cooling Coils Heat Pump/ Cooling Coils American American Standard Standard AccuClean™ AccuClean™ WholeHouse Home Whole Air Cleaner Air Cleaner 4 T X C B 0 01 C C 3 H C A A Refrigerant Type 4 = R-410A Series T = Premium (Heat Pump or Convertible Coil) Brand Coil Design X = Direct Expansion Evaporator Coil ifD AF D 1 4 5 A L F R 0 0 0 A A Filtration Size Furnace Upflow 145 = 14.5" 175 = 17.5" 210 = 21.0" 245 = 24.5" Coil Feature C = Cased A Coil A = Uncased A Coil F = Cased Horizontal Flat Coil Coil Width (Cased/Uncased) A = 14.5" /13.3" B = 17.5" / 16.3" C = 21.0" / 19.8" D = 24.5" / 23.3" H = 10.5" Furnace Downflow 14D = 14.5" 17D = 17.5" 21D = 21.0" 24D = 24.5" Air Handler 215 = 21.5" 235 = 23.5" 260 = 26.0" Major Design Series Power Supply L = Low Voltage Refrigerant Line Coupling 0 = Brazed Application AH000 = Air Handler FR000 = Furnace Model Number Distinguisher Major Design Change Minor Design Efficiency C = Standard S = Hi Efficiency (derived from 10 SEER products) Service Sequence Not Orderable Refrigerant Control 3 = TXV - Non-Bleed Perfect Fit™ Air Cleaner Coil Circuitry H = Heat Pump 1 T 2 3 456 7 F M 175 A 8 9 10 11 12 0 FR 1 1 1 2 3 4 5 6 7 8 9 10 Airflow Configuration A = Upflow Only U = Upflow / Downflow H = Horizontal Only C = Convertible - Upflow, Downflow, Left or Right Airflow Minor Design Change Service Digit - Not Orderable TXV Kits TXV Kits A = 5" Cartridge Media (Rigid) B = 5" Expandable Media 2 A Y T X V H 3 A 2 5 3 1 A A Voltage 1 = 240V Refrigerant 4 = R-410A 9 = 140V Accessory Accessory Type TXV Kit Minor Design Change Service Digit - Not Orderable Compatibility Cooling & Heat Pump Compatible Flow Control 3 = TXV - Non Bleed Perfect Fit™ Filter Accessories Major Design Change B = Internally Mounted (Mechanical Fittings) C = Internally Mounted (Mechanical Fittings) D = Internally Mounted (Mechanical Fittings) 11 12 2 Minimum Nominal Capacity in 000's BTU's Maximum Nominal Capacity in 000's BTU's Minor Design Change Service Digit - Not Orderable (; ([SDQGDEOH W For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. Permanent–Washable, 1 Inch Minor Design Change TOC-9 Effective 7/1/12 14-1011-28 Model Nomenclature Humidifiers Humidifier 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A H U M D 2 0 0 A B M 0 0 B A Humidifier Humidifier Controls Controls 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A C O N T H 0 1 A A U T O A A Brand Brand Accessory Type CONT = Control Accessory Type Accessory H = Humidifier Model Series 200, 300, 500 Model Series Major Design Change Humidifier Major Design Change Humidifier Type B = Bypass, Flow Through P = Fan Powered, Flow Through Control M = Manual A = Automatic Secondary FunctionBlank Control Type - Automatic or Manual SENS = Sensing 1310 = Height x Width (Dimensions) MHCO = Manual Humidifier Control Minor Design Change Service Digit - Not Orderable Minor Design Change Service Digit - Not Orderable Humidifier Humidifier Accessory Accessories B A Y R L Y 1 0 A S E N S A A Energy Energy Recovery Recovery Ventilator (ERV) Ventilator A ERV R 100 A 9 P 0 0 A A (ERV) Brand Accessory Product Type ERV = Energy Recovery Ventilator Description RLY = Relay PAD = Humidifier Replacement Pad PLT = Adapter Plate Feature Tier B = Future R = PSC Blower/PT Control X = Future Accessory Series Model Family (Nominal Airflow) 100 = 130 cfm 200 = 200 cfm 300 = 300 cfm Major Design Change Accessory Type SENS = Sensing 1310 = Height x Width (Dimensions) MHCO = Manual Humidifier Control Major Design Change Power Supply 1 = 115 v/1 ph/60 hz Minor Design Change Type of Defrost P = Passive Service Digit- Not Orderable Open Minor Design Change Service Digit - Not Orderable For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TOC-10 Effective 7/1/12 14-1011-28 Model Nomenclature Packaged Units Package Units 15 - Digit 4 Y C X 3 0 4 2 A 3 0 8 0 A A Packaged Units Refrigerant 4 = R-410A Type YC = Gas Electric WC = Heat Pump DC = Dual Fuel TC = Air Conditioner Model Tier C = Entry Level X = Upgrade Y = Premium Z = Leadership - (2-Stage) Cooling Capacity in 1000’s (BTUH) Efficiency Tier 3 = 13 SEER 4 = 14 SEER 6 = 16 SEER Capacity in 1000’s (BTUH) 018 042 024 048 030 060 036 Major Design Change Voltage & Phase 1 = 230V 1 Phase 3 = 230V 3 Phase 4 = 460V 3 Phase Gas Heat Input (MBTU/H) 000 (AC or HP) 075 040 096 064 120 Minor Design Change Service Digit - Not Orderable Service Digit - Not Orderable For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TOC-11 Effective 7/1/12 14-1011-28 Model Nomenclature Packaged Units Y H C 0 3 7 E 3 R Z B * * C 0 0 0 A 1 0 0 0 0 A 1 1 2 3 4 5 6 7 8 9 101112131415161718192021222324 25 Digit 1 – Unit Type T = DX Cooling Y = DX Cooling, Gas Heat Digit 15 – Supply Fan/Drive Type/Motor 0 =Standard Drive4 6 =Single Zone VAV Digit 2 – Efficiency H = High Efficiency Digit 16 – Hinged Service Access/Filters 0 =Standard Panels/Standard Filters A =Hinged Access Panels/Standard Filters B =Standard Panels/2” MERV 7 Filters C =Hinged Access Panels/2” MERV 7 Filters D =Standard Panels/2” MERV 13 Filters E =Hinged Access Panels/2” MERV 13 Filters Digit 3 – Airflow C = Convertible Digit 4,5,6 – Nominal Gross Cooling Capacity (MBh) 037 = 3 Tons 047 = 4 Tons 067 = 5 Tons Digit 7 – Major Design Sequence E = R-410A Refrigerant Digit 8 – Voltage Selection 3 = 208-230/60/3 4 = 460/60/3 Digit 9 – Unit Controls R = ReliaTel™ Microprocessor Digit 10 – Heating Capacity 0 = No Electric Heat G = 18 kW (1&3 phase) B = 6 kW (3 phase) J = 23 kW (3 phase) E = 12 kW (3 phase) L = Low Heat M = Medium Heat H = High Heat X = Low Heat, Stainless Steel Heat Exchanger Y = Medium Heat, Stainless Steel Heat Exchanger Z = High Heat, Stainless Steel Heat Exchanger Digit 11 – Minor Design Sequence A = First Sequencey Digit 12,13 – Service Sequence **Factory Assigned Digit 14 – Fresh Air Selection 0 =No Fresh Air A =Manual Outside Air Damper 0-50%2 B =Motorized Outside Air Damper 0-50% C =Economizer, Dry Bulb 0-100% without Barometric Relief5 D =Economizer, Dry Bulb 0-100% with Barometric Relief5 E =Economizer, Reference Enthalpy 0-100% without Barometric Relief5 F =Economizer, Reference Enthalpy 0-100% with Barometric Relief5 G =Economizer, Comparative Enthalpy 0-100% without Barometric Relief5 H =Economizer, Comparative Enthalpy 0-100% with Barometric Relief5 1 Standard on all variable stage units. 2 Manual outside air damper will ship factory supplied within the unit, but must be field installed. 3 High pressure control is standard on all units. 4 Constant CFM direct drive is standard for 3-5 Ton variable stage units. Digit 15 = 0, 6 3 Phase (3-5 ton) = High Efficiency Constant CFM 5 Economizer with Barometric Relief is for downflow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric Relief for horizontal configured units must be ordered as field installed accessory. Digit 17 – Condenser Coil Protection 0 =Standard Coil 1 =Standard Coil with Hail Guard 2 =Black Epoxy Pre-Coated Condenser Coil 3 =Black Epoxy Pre-Coated Condenser Coil with Hail Guard 4 =Complete Coat™ Condenser Coil 5 =Complete Coat™ Condenser Coil with Hail Guard Digit 18 – Through the Base Provisions Note: Applicable to Digit 1, T or Y models 0 =No Through the Base Provisions A =Through the Base Electric6 B =Through the Base Gas Pipinge C =Through the Base Electric and GasPipinge Digit 23 – Refrigeration Controls Note: Applicable to Digit 7 = E 0 =No Refrigeration Control3 1 =Frostat 2 =Crankcase Heater1 3 =Frostat and Crankcase Heater1 Digit 24 – Smoke Detectorr 0 =No Smoke Detector A =Return Air Smoke Detector90 B =Supply Air Smoke Detector C =Supply and Return Air Smoke Detectors90 Digit 25 – Monitoring Controls 0 =No Monitoring Controlq 1 =Clogged Filter Switchq 2 =Fan Failure Switchq 3 =Discharge Air Sensing Tubeq 4 =Clogged Filter Switch and Fan Fail Switchq 5 =Clogged Filter Switch and Discharge Air Sensing Tubeq 6 =Fan Fail Switch and Discharge Air Sensing Tubeq 7 =Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tubeq 8 =Novar Return Air Sensorw 9 =Novar 3051 Zone Sensort Digit 19 – Disconnect/Circuit Breaker (three - phase only) 0 =No Disconnect/No Circuit Breaker 1 =Unit Mounted Non-Fused Disconnect6 2 =Unit Mounted Circuit Breaker6 Digit 20 – Convenience Outlet 0 =No Convenience Outlet A =Unpowered Convenience Outlet B =Powered Convenience Outlet (three-phase only)7 Digit 21 – Communications Options 0 =No Communications Interface 3 =Novar 2024 Controls 4 =Novar 3051 Controls without Zone Sensor 5 =Novar 3051 Controls Interface with DCV 6 =BACnet™ Communications Interface Digit 22 – Refrigeration System Option 0 =Standard Refrigeration System8 B =Dehumidification Optionu 6 Through the base electric required when ordering disconnect/circuit breaker options. 7 Requires use of Disconnect or Circuit Breaker. Not Available High Efficiency 3-5 ton w/Standard Indoor Motor w/460V 8 Standard metering devices are TXVs. 9 The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not order the return air smoke detectors when using this type of accessory. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TOC-12 0 Return Air Smoke Detector cannot be ordered with Novar Controls. q These options are standard when ordering Novar Controls. w This option is used when ordering Novar Controls. e Includes gas piping and shutoff (field assembly required). r Not available with high temperature duct sensor accessory. t Novar Sensor utilized with Digit 21 = (4) Novar 3051 Controls without Zone Sensor. y Available for T/Y 3,4,5 ton high efficiency models. u Requires selection of 2” Pleated Filters (option B or C) for Digit 16. Effective 7/1/12 14-1011-28 Model Nomenclature Zone Comfort Controls Controls A Z O N E 9 5 0 A C 5 2 Z A A Brand A = American Standard Z = Unbranded Z D A M P R D M A 0 0 1 2 A A Brand Z = Zoning Damper Accessory Type Model Series CONT= Control (thermostat) ZONE = Control (zoning) RD = Round RR = Retro-Fit Round SM = Side Mount Rectangular BM = Bottom Mount Rectangular Model Series Major Design Modifications Modulating Damper (24 Volt, 60 Sec. Timing) Control Platform M= N= F = S= C= W= Zone Zone Dampers Dampers Major Design Modifications Mechanical Non-programmable Electronic (Digital Display) Five/Two Programmable Electronic (Digital Display) Seven Day Programmable Electronic (Digital Display) Communicating Wireless Dimensions 0012 = 12" Round 1014 = 10" X 14" Rectangular (motor mounted on 2nd dimension) Minor Design Change Heating Stages Service Digit Cooling Stages Equipment Application A= G= E= H= M= D= C= Z = AC / Heat (Gas or Electric) AC / Heat (Gas) AC / Heat (Electric) Heat Pump Multi-Application - AC / Heat (Gas/Elec) / Heat Pump Dual Fuel, Heat Pump, or AC and Heat (Gas/Elec) Communicating Zoning - Universal application - 3 wire Communicating zone control of AC or Heat (Gas/Elec) and Dual Fuel Heat Pump U = Universal Application - Communicating Control of AC/Heat (Gas/Elec) / Dual Fuel Heat Pump Minor Design Change Service Digit For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TOC-13 Effective 7/1/12 14-1011-28 Model Nomenclature Indoor Gas Indoor Gas Heating Units Heating Units A B N D 0 0 3 A A F 1 0 0 0 0 + Gas Heating Equipment (Digit 1) Product Type (Digit 2) T = Propeller Fan / Tubular Heat Exchanger A = Separated Combustion Propeller Fan Unit Heater B = High Efficiency Centrifugal Fan Unit Heater L = High Efficiency Indoor Duct Furnace H = High Efficiency Propeller Fan Unit Heater K = Separated Combustion Centrifugal Fan Unit Heater M = Separated Combustion Indoor Duct Furnace Fuel (Digit 3) N = Natural Gas P = LP Gas (Propane) Development Sequence (Digit 4) D = Fourth Generation Input Capacity in 1000’s (MBh) (Digit 5-7) Single Furnace 003(a) = 30 MBh 015 = 150 MBh 004(a) = 45 MBh 017 = 175 MBh (a) 006 = 60 MBh 020 = 200 MBh 007(a) = 75 MBh 022 = 225 MBh 009 = 90 MBh 025 = 250 MBh 010(b) = 100 MBh 030 = 300 MBh 012(b) = 125 MBh 035 = 350 MBh (c) 011 = 105 MBh 040 = 400 MBh (c) 120 = 120 MBh (a) Not available for high efficiency propeller fan. (b) Not available for tubular. (c) Available for tubular only. Main Power Supply (Digit 8) A = 115/60/1 B = 230/60/1 C = 208/60/3 D = 230/60/3 E = 460/60/3 F = 575/60/3 Gas Control Option (Digit 9) D = Single-Stage, Intermittent Pilot Ignition E = Two-Stage, Intermittent Pilot Ignition H = Electronic Modulating with Room T-Stat, Intermittent Pilot Ignition J = Electronic Modulating with Duct-Stat, Intermittent Pilot Ignition L = Electronic Modulating with External 4-20 mA Input N = Electronic Modulating with External 0 -10 VDC Input T = Single - Stage Direct Spark Ignition V = Two-Stage, Direct Spark Ignition Design Sequence (Digit 10) G= Seventh Design Heat Exchanger Material (Digit 11) 1 = Aluminized Steel 2 = #409 Stainless Steel2 3 = #321 Stainless Steel3 Miscellaneous Options — All Units (Digit 15) 0 = None A = #409 Stainless Steel Burners3 B = Orifice for Elevation above 2000 ft (specify elevation) Propeller Fan Unit Heater (Hi-Effic.) C = #409 Stainless Steel Draft Diverter D = Summer-Winter Switch 7 = OSHA Fan Guard E = Vertical Louvers J = Totally Enclosed Motor Centrifugal Fan Unit Heater (Hi- Effic.) C = #409 Stainless Steel Draft Diverter D = Summer-Winter Switch J = Totally Enclosed Motor E = Vertical Louvers H = Duct Discharge Flange Duct Furnace (Indoor) (Hi-Effic.) C = #409 Stainless Steel Draft Diverter D = Summer-Winter Switch F = Horizontal Louvers G = Horizontal & Vertical Louvers K = Side Access Burner Drawer (Left Hand)* L = Fan Time Delay Control M = Side Access Burner Drawer (Right Hand)* Separated Combustion Indoor Duct Furnace C = #409 Stainless Steel Draft Diverter D = Summer-Winter Switch F = Horizontal Louvers G = Horizontal & Vertical Louvers Tubular Heat Exchanger, Propeller Type J = Totally Enclosed Motor 7 = OSHA Fan Guard Notes: 1 All units are AGA approved. For CGA approved units, contact Macon Product Support. (1-877-78-Trane, Prompts 4, 1, 1, 1) 2 Available on the tubular sizes 100-400 only. 3 Not available for tubular. *The left or right hand side of the side access burner drawer, options K & M, is determined by facing the air outlet side of the duct furnace. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TOC-14 Effective 7/1/12 14-1011-28 AccuLink™ Control Schlage LiNK™ is now NEXIA™ Home Intelligence AZTSK500BB32MA • American Standard AccuLink™ Control Kit • Includes AZEMT500BB32MA control, NEXIA™ Bridge, and RP100BX Home Appliance Module • Remote access to control from computers connected to internet and compatible web enabled mobile devices including Android™, Blackberry™, iPhone™ and many other web enabled phones • Air conditioning and heating energy management • Easy Installation and Set-Up • Expandable for home management Application: • 3 Heat/2 Cool for Heat Pump • 2 Heat/2 Cool for Gas Electric See AZEMT500BB32MA for details • Use with additional AZEMT500BB32MA control • Use with additional RP200R light module and RP100BX Home Appliance Module • Use with Home Keypad Deadbolt and Home Keypad Lever Locks • Up to 231 devices may be wirelessly connected to one NEXIA™ Bridge Dimensions: • Control: 5.7" W x 4.0" H x 1.2" D LCD display 2.75" W x 1.5" H • Shipping Weight: 2.35 lbs. AZTSK500BB32MA AZEMT500BB32MAA AZEMT500BB32MA For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. • 24 Vac, Z Wave enabled control • Compatible with NEXIA™ • 7 day programmable, 4 schedules per day, may be scheduled from web or control • Remotely adjust control and view temperature from computers connected to internet and compatible web enabled mobile devices including Android™, Blackberry™, iPhone™ and many other web enabled phones • Requires NEXIA™ Bridge and Home Appliance Module for remote access • Service fee required for remote access • Control Recovery • Remote Sensing • Dual Fuel Control • Built in humidity sensor • Cooling Droop • Smart Continuous Fan • Enhanced dehumidification with variable speed indoor products • Filter service reminder alert • Maintenance reminder alert • Out of Range Temperature alert • Keypad tamper alert • Alerts may be sent by e-mail and/or text to mobile device • Limited Five Year Parts Warranty • Registered Ten Year Parts Warranty CHS-1 Application: • 3 Heat/2 Cool for Heat Pump • 2 Heat/2 Cool for Gas Electric • 7 day programmable, 4 schedules per day • Used with NEXIA™ Bridge and Home Appliance Module, included in AZTSK500BB32MA kit Compatible Systems • Gas/Oil Furnace • Air Handler/Electric Furnace • Heat Pump systems • Cooling systems May be Compatible • Conventional Boilers • Geothermal • 24 Vac Forced Air Multi Zone Systems Not Compatible • Radiant Floor • 120/240 Volt Electric Baseboard Heat • Wall Heating systems • Proprietary Communicating Systems Dimensions: • 5.7" W x 4.0" H x 1.2" D • LCD display 2.75" W x 1.5" H • Shipping Weight: 1 lb. Effective 7/1/12 14-1011-28 NEXIA™ Accessories SZLSK100AA • Home Automation Kit • Includes NEXIA™ Z-Wave to broadband bridge, two RP100BX home appliance modules, ethernet cable, and power supply • Remote appliance control from any PC with internet access and most internet enabled devices and smart phones • Secure Connection with server for homeowner protection • Easy Installation and Set-Up Application: • Use with AZEMT500BB32MA • Use with additional RP200R light module and RP100BX Home Appliance Module • Use with NEXIA™ Home Keypad Deadbolt and Home Keypad Lever Locks Dimensions: • NEXIA™ Bridge: 4.0” W x 4.8” H x 1.4” D Home Appliance Module: 4.0” W x 2.4” H x 1.6” D • Shipping Weight: 2 lbs. SZLSK100AA RP200R RP100BX RP200R Application: • Use with NEXIA™ Bridge (bridge included in AZTSK500BB32MA and SZLSK100AA kits) • Max load both outlets = 15 Amps, 1800 Watt resistive • Max load Z Wave controlled outlet = 300 Watts incandescent only • Shipping Weight:1 lb. RP100BX Application: • Use with NEXIA™ Bridge (bridge included in AZTSK500BB32MA and SZLSK100AA kits) • Max load both outlets = 15 Amps, 1800 Watt resistive • Max load Z Wave controlled outlet = 600 Watts incandescent, 1/2 HP, 1800 Watt resistive • Shipping Weight:1 lb. • Signal Repeater and Dimmer Light Module • Used to control and dim plug-in incandescent lighting • Signal Repeater and Home Appliance Module • Used to control small appliances and plug-in incandescent, fluorescent, and LED lighting. On/Off control • May be used to control/reduce standby loss from plug-in power supplies and small electronic loads For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CHS-2 Effective 7/1/12 14-1011-28 NEXIA™ Accessories BAY599 (Lever Lock) BAY599BBALLFEA BAY599SNALLFEA BAY599ABALLFEA • Wireless Home Keypad Locks can be added to a the Z-Wave network within your home • Remotely lock or unlock the door from computers connected to internet and compatible web enabled mobile devices including Android™, Blackberry™, iPhone™ and many other web enabled phones • Confirm lock status from internet enabled computer or web enabled mobile device • Assign up to 19 personalized 4 digit codes for each member of your household • Up to 3 year battery life • Provides battery level status at the lock and on the web • Available in 3 finishes: Bright Brass, Satin Nickel, Aged Bronze • Class 2 rated door lock • Lifetime limited mechanical and finish warranty • 1-year limited electronics warranty BAY369 (Deadbolt) BAY369BBADBBEA BAY369SNADBBEA BAY369ABADBBEA • Wireless Home Keypad Deadbolt Locks can be added to the Z-Wave network within your home • Remotely lock or unlock the door from computers connected to internet and compatible web enabled mobile devices including Android™, Blackberry™, iPhone™ and many other web enabled phones • Confirm lock status from internet enabled computer or web enabled mobile device • Assign up to 19 personalized 4 digit codes for each member of your household • Up to 3 year battery life • Provides battery level status at the lock and on the web • Available in 3 finishes: Bright Brass, Satin Nickel, Aged Bronze • Class 2 rated door lock • Lifetime limited mechanical and finish warranty • 1-year limited electronics warranty For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CHS-3 Model number and finish: • BAY599BBALLFEA - Bright Brass BAY599SNALLFEA - Satin Nickel BAY599ABALLFEA - Aged Bronze Application: • Use with NEXIA™ Bridge (included in AZTSK500BB32MA kit) • Carton Size: 6" x 7.75" x 9.56" • Shipping Weight: 5.5 lbs. Model number and finish: • BAY369BBADBBEA - Bright Brass BAY369SNADBBEA - Satin Nickel BAY369ABADBBEA - Aged Bronze Application: • Use with NEXIA™ Bridge (included in AZTSK500BB32MA kit) • Carton Size: 5.75" x 7.93" x 8.5" • Shipping Weight: 6 lbs. Effective 7/1/12 14-1011-28 NEXIA™ Accessories WCW100NNSL • NEXIA™ Web Camera - Wireless • Indoor, fixed camera (power supply included) • Remotely monitor your home from any PC with internet access and most internet enabled devices and smart phones • Secure Connection with server for homeowner protection • Plug and Play with System • Privacy button Application: • VGA (640x480) resolution • Operating Temp -5C to 50C • Wireless - 802.11b/g - WEP 64/128, WPA-PSK, WPA2 Dimensions: • 3.8” W x 3.5” H x 1.4” D • Shipping Weight: 1 lb WCW100NNSL WCE100NNSL WCE100NNSL • NEXIA™ Web Camera - Wired • Indoor, fixed camera (power supply included) • Remotely monitor your home from any PC with internet access and most internet enabled cell phones • Secure Connection with server for homeowner protection • Plug and Play with System • Privacy button Application: • VGA (640x480) resolution • Operating Temp -5C to 50C Dimensions: • 3.8” W x 3.5” H x 1.4” D • Shipping Weight: 1 lb Remote Sensors BAYSEN01ATEMPA • Outdoor Temperature Sensor for Use with AZEMT500BB Controls • Accuracy +/– 1.5°F over 32°F to 100°F • Display Range -40°F to 140°F ZZSENSAL0400AA • Indoor Sensor for Use with AZEMT500BB Controls • Operating Ambient Temperature Range: 20° to 120°F (-6.7° to 48.9°C) • Display Range: 20° to 120°F (-6.7° to 48.9°C) • Sensor Accuracy: +/–.5°F at 75°F • Operating Relative Humidity: 5% to 90% non-condensing For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CHS-4 Dimensions in in. (mm): • 1.54 (39)w x 1.93 (49)h x .625 (1.6)d • Storage Temperature: -40° to 140°F (-40° to 60°C) • Finish: White Effective 7/1/12 14-1011-28 Split System Cooling Single Phase – 1½-5 Tons Table SC-1-A — Platinum ZM Split System Cooling (Previously Allegiance 20) — with AccuLink™ 123 Model Number Power Supply Nom. Cap. Uncrated Shipping CoolingDimensions(in.) Weight Sound** Max. (BTUH) H W D (lbs.) Rating MCA* Fuse* 4A7Z0024A1000C 200/230/1/6024,000 4A7Z0036B1000A 200/230/1/6036,000 4A7Z0048B1000A 200/230/1/6048,000 4A7Z0060A1000C 200/230/1/6060,000 4537 4537 4537 4537 34 34 34 34 375 375 460 460 68 72 76 76 14 19 26 31 20 30 40 50 Line Size OD OD GasLiq. /4 /4 7 /8 7 /8 /8 /8 3 /8 3 /8 3 3 3 3 Platinum ZM (4A7Z0) Table SC-1-B — Platinum XM Split System Cooling (Previously Allegiance 16) Model Number Power Supply 4A7A6024G1000A230/1/60 4A7A6036G1000A230/1/60 4A7A6048G1000B230/1/60 4A7A6060E1000B 230/1/60 Nom. Cap. Uncrated CoolingDimensions(in.) (BTUH) H W D 24,000 4137 34 36,000 4537 34 48,000 4537 34 60,000 4537 34 Shipping Line Size (in) Weight Sound** Max. OD OD (lbs.) RatingMCA* Fuse* GasLiq. 276 283 308 312 72 72 73 74 14 22 28 39 20 35 45 60 /8 /4 7 /8 11/8 /8 /8 3 /8 3 /8 5 3 3 3 Platinum XM (4A7A6) Table SC-1-C — Gold XI Split System Cooling (Previously Allegiance 15) Gold XI (4A7A5) Model Power Number Suppy Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 4A7A5018E1000A 208/230/1/60 4A7A5024E1000A 208/230/1/60 4A7A5030E1000A 208/230/1/60 4A7A5036E1000A 208/230/1/60 4A7A5042E1000A 208/230/1/60 4A7A5048E1000A 208/230/1/60 4A7A5049E1000B 208/230/1/60 4A7A5060E1000A 208/230/1/60 4A7A5061E1000B4230/1/60 18,000 24,000 30,000 36,000 42,000 48,000 48,000 60,000 60,000 29 29 33 37 41 45 45 45 45 33 33 37 37 37 37 37 37 37 30 30 34 34 34 34 34 34 34 200 201 234 228 272 282 304 285 312 75 75 75 75 75 75 74 75 75 9 9 12 19 23 26 26 34 39 15 15 20 30 40 45 45 60 60 /8 /4 3 /4 3 /4 7 /8 7 /8 7 /8 7 /8 11/8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 5 3 3 3 1Must use ACONT900 or AZONE950 control with communicating systems. 2BAYACHP024A required for 24 volt mode. 3Because of limited capabilities, please refer to the product ratings for approved combinations. 41 compressor, 2 stages. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Rated in accordance with AHRI Standard 270-2008. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-1 Effective 7/1/12 14-1011-28 Split System Cooling Single Phase – 1½-5 Tons 2016 15 Table SC-2-A — Features (4A7Z0)(4A7A6) (4A7A5) • • • • • • • • • • • • • • • • • • • • • • • SEER up to.............................................................................................................................................................. 20.00 18.00 17.00 Duration™ compressor........................................................................................................................................... 2 1 ✔ Number of stages..................................................................................................................................................... 2 2 1 Comfort-R™ mode approved.................................................................................................................................. ✔ ✔ ✔ AccuLink™ system................................................................................................................................................. ✔ — — Charge Assist™ fast/accurate charging every time............................................................................................... ✔ — — DuraBase™ base, fast complete drain, weatherproof............................................................................................ ✔ ✔ ✔ Easy-Sess™ cabinet, service access..................................................................................................................... ✔ ✔ ✔ Spine Fin™ coil....................................................................................................................................................... ✔ ✔ ✔ Compressor sound enclosure.................................................................................................................................. ✔ — ✔ Compressor sump heat - factory installed............................................................................................................... ✔— — Factory supplied charge .......................................................................................................................................... R-410A R-410A R-410A Glossy corrosion resistant finish.............................................................................................................................. ✔ ✔ ✔ High pressure switch................................................................................................................................................ ✔ ✔ ✔ Low pressure switch................................................................................................................................................. ✔ ✔— Internal high / low pressure & temperature protection............................................................................................. ✔ ✔ ✔ Liquid line filter drier - factory installed..................................................................................................................... ✔ ✔ ✔ Quick start kit-factory installed................................................................................................................................. ✔ —018-030,060 Seacoast shield - factory installed........................................................................................................................... ✔ ✔ ✔ Spinnaker gray cabinet............................................................................................................................................. ✔ ✔ ✔ 12-year registered limited warranty on compressor,10-year on outdoor coil & all other functional parts (Residential Use)1.................................................................................................. ✔ ✔ — 10-year registered limited warranty on compressor, outdoor coil & all other functional parts (Residential Use)1......................................................................... — — ✔ Extended warranties available ............................................................................................................................. ✔ ✔ ✔ Table SC-2-B — Optional Accessories Model Number Description Shipping Weight AY28X079...................... Evaporator defrost control..................................................1................................................ BAYACHP024A.............. 24 Volt Wiring Harness.......................................................1................................................ BAYCAKT001................. Charge Assist™ Solenoid Kit...........................................3................................................ BAYCCHT300................ Crankcase Heater Kit (Reciprocating)................................1................................................ BAYCCHT301................ Crankcase Heater Kit (Scroll).............................................1................................................ BAYCCHT302................ Crankcase Heater Kit (Scroll).............................................1................................................ BAYECMT023................ Extreme Conditions Mounting Kit (Base 2/3).....................2................................................ BAYECMT004................ Extreme Conditions Mounting Kit (Base 4)........................2................................................ BAYISLT101................... Rubber Isolators.................................................................1................................................ BAYKSKT260................. Start kit (Scroll)...................................................................1................................................ BAYLEGS002................. Snow Legs - Base and Cap 6" High (Black)......................1................................................ BAYLEGS003................. 4" Extension (Black)...........................................................1................................................ TAYASCT501A23........ Anti-Short Cycle Timer.......................................................2................................................ PAI003094.................... Heresite Spraypaint............................................................1................................................ — ✔ ✔ — — — — ✔ ✔ — ✔ ✔ ✔ ✔ — ✔ — — — — — 1½-2½ ✔3½-5 — 3 — 1½-2 ✔ 2½-5 ✔ ✔ ✔039-049,061 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Comfort Controls — See Comfort Controls/Zone Sensors Section 1Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. 2Not for use with programmable thermostats. 3Activated on power off. 4Used for additional seacoast corrosion protection. Refer to bulletin number UN-SVB11A-EN for application information. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-2 Effective 7/1/12 14-1011-28 Split System Cooling Single Phase – 1½-5 Tons Table SC-3-A— Gold SI Split System Cooling (Previously Allegiance 13) Model Power Number Suppy Gold SI (4A7A3) 4A7A3018E1000A 4A7A3024E1000A 4A7A3030E1000A 4A7A3036D1000A 4A7A3042D1000A 4A7A3048D1000A 4A7A3060D1000A Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 200/230/1/6017,000 200/230/1/6023,000 200/230/1/6028,500 208/230/1/6034,500 208/230/1/6040,500 208/230/1/6046,500 208/230/1/60 58,500 29 33 29 33 29 33 33 33 29 37 29 37 37 37 30 30 30 30 34 34 34 191 196 200 217 228 235 261 76 75 76 75 74 75 75 9 12 15 18 26 28 35 15 20 25 30 45 50 60 /8 /8 3 /4 3 /4 3 /4 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 5 3 5 3 Table SC-3-B — American Standard R-410A Split System Cooling — Single Phase Model Power Number Suppy Silver Series SI (4A7M3) Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 4A7M3018A1000A 200/230/1/60 18,000 29 25½ 23½ 4A7M3024A1000A 200/230/1/60 24,000 29 25½23½ 4A7M3030A1000A 200/230/1/60 29,400 29 25½23½ 4A7M3036A1000A 200/230/1/60 34,400 29 25½23½ 4A7M3042A1000A 200/230/1/60 42,000 29 2928½ 4A7M3048A1000A 200/230/1/60 47,000 29 2928½ 4A7M3060A1000A 200/230/1/60 58,000 29 2928½ 177 180 181 184 190 191 194 83 81 83 83 82 83 83 10 12 16 18 27 29 35 15 15 25 30 45 50 60 /8 /8 3 /4 3 /4 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 PhasING Out 5 3 5 3 Table SC-3-C — Silver SI Split System Cooling (Previously 4A7M3) Model Power Number Suppy Silver SI (4TTM3) Nom. Cap. Uncrated Shipping Line Size (in) CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 4TTM3018A1000C 200/230/1/60 18,000 4TTM3024A1000C 200/230/1/60 24,000 4TTM3030A1000C 200/230/1/60 29,400 4TTM3036A1000C 200/230/1/60 34,400 4TTM3042A1000C 200/230/1/6042,000 4TTM3048A1000C 200/230/1/6047,000 4TTM3060A1000C 200/230/1/6058,000 29 25½ 23½ 2925½23½ 2925½23½ 2925½23½ 29 29 28½ 29 29 28½ 29 29 28½ 177 180 181 184 190 191 194 78 78 78 78 79 79 79 10 12 16 18 27 29 35 15 15 25 30 45 50 60 /8 /8 3 /4 3 /4 7 /8 7 /8 7 /8 5 5 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 1 1 compressor, 2 stages. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Rated in accordance with AHRI Standard 270-2008. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-3 Effective 7/1/12 14-1011-28 Split System Cooling Single Phase – 1½-5 Tons (4A7A3) (4A7M3) (4TTM3) SEER up to.................................................................................................................................................................. 16.00 14.75 14.75 Duration™ compressor............................................................................................................................................... ✔ ✔ 14.75 Comfort-R™ mode approved...................................................................................................................................... ✔ ✔ ✔ DuraBase™ base, fast complete drain, weatherproof................................................................................................ ✔ — — Easy-Sess cabinet, service access & refrigerant connections with full coil protection............................................... ✔ — — Spine Fin™ coil........................................................................................................................................................... ✔ — — Duration™ coil............................................................................................................................................................ — ✔ ✔ Quick start kit-factory installed..................................................................................................................................... 1½-3,5 1½-3,5 1½-3,5 Factory supplied charge .............................................................................................................................................. R-410A R-410A R-410A Glossy corrosion resistant finish.................................................................................................................................. ✔ ✔ ✔ High pressure switch.................................................................................................................................................... ✔ ✔ ✔ Internal high / low pressure & temperature protection................................................................................................. ✔ — ✔ Liquid line filter drier - factory installed......................................................................................................................... ✔ — — Liquid line filter drier - factory supplied for field install................................................................................................. — ✔ ✔ Sound enclosure.......................................................................................................................................................... 1½-2 — — Spinnaker gray cabinet................................................................................................................................................. ✔—— Tarpolin gray cabinet.................................................................................................................................................... — ✔ ✔ 10-year registered limited warranty on compressor, outdoor coil & all other functional parts (Residential Use)3 ........................................................................................................... ✔ ✔ ✔ Extended warranties available ................................................................................................................................. ✔ ✔ ✔ • • • • • • • • • • • • • • • • • • • PHasING out Table SC-4-A — Features Table SC-4-B — Optional Accessories Model Number Description Shipping Weight PHasING out AY28X079................Evaporator defrost control kit............................ 1............................................................................ ✔ ✔ ✔ BAYCCHT300..........Crankcase Heater (Reciprocating).................... 1............................................................................ 1½-31½-31½-3 BAYECMT023..........Extreme Conditions Mounting Kit (Base 2/3).... 2............................................................................ 1½-3 — — BAYECMT004..........Extreme Conditions Mounting Kit (Base 4)....... 2............................................................................ 3½-5— — BAYECMT021..........Extreme Conditions Mounting Kit.................................................................................................... — ✔ ✔ BAYISLT101.............Rubber isolators................................................ 1............................................................................ ✔ ✔ ✔ BAYKSKT260...........Start kit (Scroll) ................................................ 1............................................................................ 3½-4— — BAYKSKT263...........Start kit............................................................................................................................................ — 3½-4 3½-4 BAYLEGS002...........Snow Legs - Base and Cap 6" High (Black)..... 1............................................................................ ✔ — — BAYLEGS003...........4" Extension (Black).......................................... 1............................................................................ ✔ — — BAYLOAM103..........Low Ambient Kit................................................ 1............................................................................ ✔ ✔4 ✔4 BAYSEAC001...........Seacoast Kit...................................................... 1............................................................................ ✔ — — TAYASCT501A12 .Anti-Short Cycle Timer...................................... 2............................................................................ ✔ — — PAI003095..............Heresite Spraypaint........................................... 1............................................................................ ✔ — — Comfort Controls — See Comfort Controls/Zone Sensors Section 1Not for use with programmable thermostats. 2Activated on Power Off. 3Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. 4For applications requiring BAYLOAM103, an 8x8 weather proof electrical enclosure is required in order to locate the low ambient controller external to the unit. 5Used for additional seacoast corrosion protection. Refer to bulletin number UN-SVB11A-EN for application information. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-4 Effective 7/1/12 14-1011-28 Split System Cooling Single Phase – 1½-5 Tons Table SC-5-A— American Standard 14 Split System Cooling — Single Phase Model Power Number Suppy Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 4A7B4018E1000A 208/230/1/6018,000 4A7B4024E1000A 208/230/1/6024,000 4A7B4030E1000A 208/230/1/6030,000 4A7B4036E1000A 208/230/1/6036,000 American Standard 14 4A7B4042E1000A 208/230/1/6042,000 4A7B4048E1000A 208/230/1/6048,000 (4A7B4) 4A7B4049E1000B 208/230/1/6048,000 4A7B4060E1000A 208/230/1/6060,000 4A7B4061E1000A1230/1/60 60,000 29 33 29 33 33 37 37 37 41 37 45 37 45 37 45 37 45 37 30 30 34 34 34 34 34 34 34 200 201 234 228 272 282 304 285 312 79 79 80 78 80 80 76 80 76 9 9 12 19 23 26 26 34 39 15 5/8 15 3/4 20 3/4 30 3/4 40 7/8 45 7/8 45 7/8 60 7/8 60 11/8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 PhasING Out Table SC-5-B — Silver XI Split System Cooling (Previously 4A7B4) Model Power Number Suppy Silver XI (4TTB4) Nom. Cap. Uncrated Shipping Line Size (in) CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 4TTB4018E1000B 208/230/1/60 18,000 4TTB4024E1000B 208/230/1/60 24,000 4TTB4030E1000B 208/230/1/60 30,000 4TTB4036E1000B 208/230/1/60 36,000 4TTB4042E1000B 208/230/1/60 42,000 4TTB4048E1000B 208/230/1/60 48,000 4TTB4049E1000C 208/230/1/6048,000 4TTB4060E1000B 208/230/1/60 60,000 4TTB4061E1000B1230/1/60 60,000 29 33 29 33 33 37 37 37 41 37 45 37 45 37 45 37 45 37 30 30 34 34 34 34 34 34 34 200 201 234 228 272 282 304 285 312 79 79 80 78 80 80 76 80 76 9 9 12 19 23 26 26 34 39 15 15 20 30 40 45 45 60 60 /8 /4 3 /4 3 /4 7 /8 7 /8 7 /8 7 /8 11/8 5 3 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 Table SC-5-C— American Standard 13 SEER Split System Cooling — Single Phase Model Power Number Suppy 4A7B3018D1000A 4A7B3024D1000A 4A7B3030D1000A 4A7B3036D1000A 4A7B3042D1000A American Standard 13 4A7B3048D1000A (4A7B3) 4A7B3060D1000A Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 200/230/1/6017,000 200/230/1/6023,000 200/230/1/6028,500 200/230/1/6034,500 200/230/1/6040,500 200/230/1/6046,500 200/230/1/6058,500 29 33 29 33 29 33 33 33 29 37 29 37 37 37 30 30 30 30 34 34 34 191 196 200 217 228 235 261 78 78 78 78 79 79 80 9 11 15 18 26 28 35 15 15 25 30 45 50 60 /8 /8 3 /4 3 /4 3 /4 7 /8 7 /8 5 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 PhasING Out 5 3 Table SC-5-D — Silver SI Split System Cooling (Previously 4A7B3) Silver SI (4TTB3) Model Power Number Suppy Nom. Cap. Uncrated Shipping Line Size (in) CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 4TTB3018E1000A 4TTB3024E1000A 4TTB3030E1000B 4TTB3036E1000B 4TTB3042D1000B 4TTB3048D1000B 4TTB3060D1000B 17,000 23,000 28,500 34,500 40,500 46,500 58,500 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 29 29 29 29 29 29 37 33 33 33 33 37 37 37 30 30 30 30 34 34 34 191 196 200 186 228 235 261 78 78 78 74 79 79 80 9 12 15 20 26 28 35 15 20 25 35 45 50 60 /8 /8 3 /4 3 /4 3 /4 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 5 3 5 3 11 compressor, 2 stages. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Rated in accordance with AHRI Standard 270-2008. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-5 Effective 7/1/12 14-1011-28 Split System Cooling Single Phase – 1½-5 Tons (4A7B4) (4TTB4) (4A7B3) (4TTB3) SEER up to.................................................................................................................................................. 16.0016.0015.0014.00 Recip compressor........................................................................................................................................ 1½-2½ 1½-2½ 1½-3 — Scroll compressor........................................................................................................................................ 3-5 3-5 3½-5 ✔ Comfort-R™ mode approved...................................................................................................................... ✔ ✔ ✔ ✔ DuraBase™ base, fast complete drain, weatherproof................................................................................ ✔ ✔ ✔ ✔ Easy-Sess cabinet, service access & refrigerant connections with full coil protection............................... ✔ ✔ ✔ ✔ Spine Fin™ coil........................................................................................................................................... ✔ ✔ ✔ ✔ Quick start kit-factory installed..................................................................................................................... 1½-2½ 1½-2½ 1½-3 1½-2½ Sound enclosures........................................................................................................................................ 1½-2½ 1½-2½ — — Factory supplied charge .............................................................................................................................. R-410AR-410AR-410A R-410A Glossy corrosion resistant finish.................................................................................................................. ✔ ✔ ✔ ✔ High pressure switch.................................................................................................................................... ✔ ✔ ✔ ✔ Internal high / low pressure & temperature protection................................................................................. ✔ ✔ ✔ ✔ Liquid line filter drier - factory installed......................................................................................................... ✔ ✔ ✔ ✔ Polyslate gray cabinet.................................................................................................................................. ✔ ✔ ✔ ✔ 10-year registered limited warranty on compressor, outdoor coil & all other functional parts (Residential Use)3 ........................................................................................... ✔ ✔ ✔ ✔ Extended warranties available ................................................................................................................. ✔ ✔ ✔ ✔ PHasING out • • • • • • • • • • • • • • • • PHasING out Table SC-6-A — Features Table SC-6-B — Optional Accessories Description Shipping Weight PHasING out Model Number PHasING out AY28X079................Evaporator defrost control kit............................ 1........................................................... ✔ ✔ ✔ ✔ BAYCCHT300..........Crankcase Heater (Reciprocating).................... 1........................................................... 1½-2½ 1½-2½ 1½-3 1½-3 BAYCCHT301..........Crankcase Heater (Scroll)................................. 1........................................................... 3½-5 3½-5 3½-4 3½-5 BAYCCHT302..........Crankcase Heater (Scroll)................................. 1........................................................... 3 3 — — BAYECMT023..........Extreme Conditions Mounting Kit (Base 2/3).... 2........................................................... 1½-21½-21½-3 1½-3 BAYECMT004..........Extreme Conditions Mounting Kit (Base 4)....... 2........................................................... 2½-52½-53½-5 3½-5 BAYISLT101.............Rubber isolators................................................ 1........................................................... ✔ ✔ ✔ ✔ BAYKSKT260...........Start kit (Scroll) ................................................ 1........................................................... 3-5 3-5 3½-5 3-5 BAYLEGS002...........Snow Legs - Base and Cap 6" High (Black)..... 1........................................................... ✔ ✔ ✔ ✔ BAYLEGS003...........4" Extension (Black).......................................... 1........................................................... ✔ ✔ ✔ ✔ BAYLOAM103..........Low Ambient Kit................................................ 1........................................................... ✔ ✔ ✔ ✔ BAYSEAC001...........Seacoast Kit...................................................... 1........................................................... ✔ ✔ ✔ ✔ TAYASCT501A12 .Anti-Short Cycle Timer...................................... 2........................................................... ✔ ✔ ✔ ✔ PAI003094..............Heresite Spraypaint........................................... 1........................................................... ✔ ✔ ✔ ✔ Comfort Controls — See Comfort Controls/Zone Sensors Section 1Not for use with programmable thermostats. 2Activated on Power Off. 3Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. 4Used for additional seacoast corrosion protection. Refer to bulletin number UN-SVB11A-EN for application information. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-6 Effective 7/1/12 14-1011-28 Split System Cooling Single Phase – 1½-5 Tons Table SC-7-A— American Standard 13 Split System Cooling -- Single Phase Model Power Number Suppy 2A7B3018A1000A 2A7B3024A1000A 2A7B3030A1000A 2A7B3036A1000A 2A7B3042A1000A American Standard 13 2A7B3048A1000A (2A7B3) 2A7B3060A1000A Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 200/230/1/6017,000 200/230/1/6023,000 200/230/1/6028,500 208/230/1/6034,500 200/230/1/6040,500 200/230/1/6046,500 208/230/1/6058,500 26 29 33 29 33 33 33 33 33 37 41 37 41 37 26 26 30 30 34 34 34 182 195 225 220 283 307 303 76 78 78 76 79 79 79 8 12 13 18 21 25 33 15 20 20 30 35 40 50 1 /8 /4 5 /4 /16 3 /4 5/16 7 3 /8 /8 7 3 /8 /8 11/8 3/8 11/8 3/8 5 PhasING Out 3 Table SC-7-B— R-22 Split System Dry Ship Replacement Condensing Units (Previously 2A7B3) Model Power Number Suppy 2TTB3018A1000C 2TTB3024A1000C 2TTB3030A1000C 2TTB3036A1000C 2TTB3042A1000C American Standard 13 2TTB3048A1000C (2TTB3) 2TTB3060A1000C Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 200/230/1/6017,000 200/230/1/6023,000 200/230/1/6028,500 208/230/1/6034,500 200/230/1/6040,500 200/230/1/6046,500 208/230/1/6058,500 26 29 33 29 33 33 33 33 33 37 41 37 41 37 26 26 30 30 34 34 34 182 195 225 220 283 307 303 76 78 78 76 79 79 79 8 12 13 18 21 25 33 15 20 20 30 35 40 50 /8 1/4 /4 5/16 3 /4 5/16 7 /8 3/8 7 /8 3/8 11/8 3/8 11/8 3/8 5 3 Table SC-7-C — R-22 Split System Dry Ship Replacement Condensing Unit Model Power Number Suppy Silver SI (2TTM3) Nom. Cap. Uncrated Shipping Line Size (in) CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 2TTM3018A1000A1 200/230/1/60 18,000 2TTM3024A1000A1200/230/1/60 24,000 2TTM3030A1000A1200/230/1/60 29,400 2TTM3036A1000A 200/230/1/60 34,400 2TTM3042A1000A 200/230/1/6042,000 4TTM3048A1000A 200/230/1/6047,000 2TTM3060A1000A 200/230/1/6058,000 29 25½ 23½ 29 25½ 23½ 29 25½ 23½ 2925½23½ 29 29 28½ 29 29 28½ 29 29 28½ 161 161 170 152 192 192 198 72 72 77 77 79 79 79 11.5 11.5 13.9 20.6 26.6 26.6 33.3 20 20 20 35 45 45 50 /8 /8 3 /4 3 /4 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 5 3 5 3 12TTM3018-030 units combined with indoor coils having non-equalizing expansion valves may require the use of a hard start or start assist kit. Follow the outdoor unit manufacturer's guidelines. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Rated in accordance with AHRI Standard 270-2008. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-7 Effective 7/1/12 14-1011-28 Split System Cooling Single Phase – 1½-5 Tons Table SC-8-A — Features (2A7B3)(2TTB3)(2TTM3) SEER up to................................................................................................................................................ 13.25 13.25 14.75 Duration™ compressor............................................................................................................................. ✔ ✔ ✔ Comfort-R™ mode approved.................................................................................................................... ✔ ✔ ✔ DuraBase™ base, fast complete drain, weatherproof.............................................................................. ✔ ✔ — Easy-Sess cabinet, service access & refrigerant connections with full coil protection............................. ✔ ✔ — Spine Fin™ coil......................................................................................................................................... ✔. ✔ — Duration™ coil.......................................................................................................................................... —. — ✔ Refrigerant - (R-22 not factory supplied).................................................................................................... R-22 R-22 R-22 Glossy corrosion resistant finish................................................................................................................ ✔ ✔ ✔ Compressor sound enclosure.................................................................................................................... 3½-4 3½-4 — Internal high / low pressure & temperature protection............................................................................... ✔ ✔ — Liquid line filter drier - factory installed....................................................................................................... ✔ ✔ — Liquid line filter drier - factory supplied for field install............................................................................... — ✔ ✔ Polyslate gray cabinet................................................................................................................................ ✔ ✔ — Start kit - factory installed........................................................................................................................... 1½-2½,3½-51½-2½,3½-5 — Tarpolin gray cabinet.................................................................................................................................. — ✔ ✔ 5-year registered limited warranty on compressor, outdoor coil & all other functional parts (Residential Use)3 ......................................................................................... ✔ ✔ ✔ Extended warranties available ............................................................................................................... ✔ ✔ ✔ PHasING out • • • • • • • • • • • • • • • • • • Table SC-8-B — Optional Accessories Model Number Description Shipping Weight PHasING out AY28X079....................Evap. Defrost Control Kit ......................................................1.................................. ✔ ✔ ✔ BAYCCHT300..............Crankcase Heater Kit (Reciprocating)..................................1.................................. 1½-2½,3½-41½-2½,3½-4 1½-2½ BAYCCHT301..............Crankcase Heater Kit (Scroll)...............................................1.................................. 3 3,5 3-5 BAYECMT023..............Extreme Conditions Mounting Kit (Base 2/3).2.......................................................... 1½-3 1½-3 — BAYECMT004..............Extreme Conditions Mounting Kit (Base 4) .. 2.......................................................... 3½-5 3½-5 — BAYECMT021..............Extreme Conditions Mounting Kit.............................................................................. — — ✔ BAYISLT101.................Rubber Isolators....................................................................1.................................. ✔ ✔ ✔ BAYKSKT260...............Start Kit.................................................................................1.................................. 3 3 1½-2½ BAYKSKT263...............Start kit...................................................................................................................... — 3½-4 3-5 BAYLEGS002...............Snow Legs - Base and Cap 6" High (Black).........................1.................................. ✔ ✔ — BAYLEGS003...............4" Extension (Black)..............................................................1.................................. ✔ ✔ — BAYLOAM103..............Low Ambient Kit....................................................................1.................................. ✔ ✔ ✔4 BAYSDEN001..............Single Cylinder Compressor Enclosures..............................8.................................. 1½-2½ 1½-2½ — BAYSDEN003..............Small Scroll Compressor Enclosures...................................8.................................. 3 3 — BAYSDEN004..............Large Scroll Compressor Enclosures...................................8.................................. 5 5 — BAYSEAC001...............Seacoast Kit .........................................................................1.................................. ✔ ✔ — TAYASCT501A12 .....Anti-Short Cycle Timer..........................................................2.................................. ✔ ✔ — Comfort Controls — See Comfort Controls/Zone Sensors Section 1Not for use with programmable thermostats. 2Activated on Power Off. 3Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. 4For applications requiring BAYLOAM103, an 8x8 weather proof electrical enclosure is required in order to locate the low ambient controller external to the unit. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-8 Effective 7/1/12 14-1011-28 Split System Cooling Three Phase – 2½-5 Tons Table SC-9-A— 13 SEER Split Cooling Single Compressor Model Power Number Suppy 13 SEER 4A7C3030A3000B 4A7C3036A3000B 4A7C3042D3000A 4A7C3048D3000A 4A7C3060D3000A Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 200/230/3/60 30,000 200/230/3/60 36,000 208/230/3/6042,000 208/230/3/60 48,000 208/230/3/6060,000 33 33 37 33 29 37 29 37 37 37 30 30 34 34 34 224 229 228 235 294 78 78 79 79 80 10 15 18 18 21 15 25 30 30 35 33 33 30 37 33 30 3337 34 3337 34 41 37 34 222 227 254 252 294 78 78 79 79 80 5 7 9 9 12 15 15 15 15 20 /4 /4 3 /4 7 /8 7 /8 3 3 /16 /8 3 /8 3 /8 3 /8 5 3 PhasING Out 4A7C3030A4000B 460/3/60 4A7C3036A4000B 460/3/60 4A7C3042A4000B 460/3/60 4A7C3048A4000B 460/3/60 4A7C3060A4000B 460/3/60 30,000 36,000 42,000 48,000 60,000 /4 /4 3 /4 7 /8 7 /8 /16 /8 3 /8 3 /8 3 /8 3 5 3 3 Table SC-9-B — Silver SI Split System Cooling (Previously 4A7C3) Silver SI (4TTA3) Model Number Power Supply Nom. Cap. UncratedShipping Line Size (in) CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D(lbs.) Rating MCA* Fuse* GasLiq. 4TTA3030A3000C 4TTA3036A3000C 4TTA3042D3000C 4TTA3048D3000C 4TTA3060D3000C 200/230/3/60 200/230/3/60 208/230/3/60 208/230/3/60 208/230/3/60 30,000 36,000 42,000 48,000 60,000 33 33 37 33 29 37 29 37 37 37 30224 30229 34228 34235 34294 78 78 79 79 80 10 15 18 18 21 15 25 30 30 35 3 /4 /4 3 /4 7 /8 7 /8 3 3 3 4TTA3030A4000C 4TTA3036A4000C 4TTA3042D4000C 4TTA3048D4000C 4TTA3060D4000C 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 30,000 36,000 42,000 48,000 60,000 33 33 30222 37 33 30227 33 37 34254 3337 34 252 4137 34 294 78 78 79 79 80 5 7 9 9 12 15 15 15 15 20 3 /4 /4 3 /4 7 /8 7 /8 3 3 3 /8 /8 3 /8 3 /8 3 /8 /8 /8 3 /8 3 /8 3 /8 * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Rated in accordance with AHRI Standard 270-2008. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-9 Effective 7/1/12 14-1011-28 Split System Cooling Three Phase – 2½-5 Tons (4A7C3)(4TTA3) SEER up to.................................................................................................................................................................................. 14.50 14.50 Duration™ compressor............................................................................................................................................................... ✔ ✔ Comfort-R™ mode approved...................................................................................................................................................... ✔ ✔ DuraBase™ base, fast complete drain, weatherproof................................................................................................................ ✔ ✔ Easy-Sess™ cabinet, service access & refrigerant connections with full coil protection........................................................... ✔ ✔ Spine Fin™ coil........................................................................................................................................................................... ✔ ✔ Compressor sump heat - factory installed................................................................................................................................... ✔ ✔ Factory supplied charge .............................................................................................................................................................. R-410AR-410A Glossy corrosion resistant finish.................................................................................................................................................. ✔ ✔ Internal high / low pressure & temperature protection................................................................................................................. ✔ ✔ Liquid line filter drier - factory installed......................................................................................................................................... ✔ ✔ Low pressure switch..................................................................................................................................................................... ✔ ✔ Polyslate gray cabinet.................................................................................................................................................................. ✔ ✔ 5-year registered limited warranty on compressor, outdoor coil & 1-year on all other functional parts (Commercial Use) ....................................................................................................................................... ✔ ✔ 5-year registered limited warranty on compressor, outdoor coil & all other functional parts (Residential Use) .......... ✔ ✔ Extended warranties available ................................................................................................................................................. ✔ ✔ • • • • • • • • • • • • • • • • PHasING out Table SC-10-A — Features Table SC-10-B — Optional Accessories Description Shipping Weight PHasING out Model Number AY28X079........................Evaporator Defrost Control...............................................1.................................................................... ✔ ✔ BAYECMT023..................Extreme Conditions Mounting Kit (Base 2/3)....................2.................................................................... 2½-32½-3 BAYECMT004..................Extreme Conditions Mounting Kit (Base 4).......................2.................................................................... 3½-53½-5 BAYISLT101.....................Rubber Isolators................................................................1.................................................................... ✔ ✔ BAYLEGS002...................Snow Legs - Base and Cap 6" High (Black).....................1.................................................................... ✔ ✔ BAYLEGS003...................4" Extension (Black)..........................................................1.................................................................... ✔ ✔ BAYLOAM1033 ..............Low Ambient Kit................................................................1.................................................................... ✔ ✔ BAYSEAC001...................Seacoast Kit......................................................................1.................................................................... ✔ ✔ BAYTFMR003A................77VA Transformer 230V/24V.............................................4.................................................................... ✔ ✔ BAYTFMR004A................77VA Transformer 460V/24V.............................................4.................................................................... ✔ ✔ TAYASCT501A12 .........Anti-Short Cycle Timer......................................................2.................................................................... ✔ ✔ PAI003094......................Heresite Spraypaint...........................................................1.................................................................... ✔ ✔ Comfort Controls — See Comfort Controls/Zone Sensors Section 1Do not use with programmable thermostats. 2Activated on Power Off. 3 Not approved for use with hot gas by-pass application. 4Used for additional seacoast corrosion protection. Refer to bulletin number UN-SVB11A-EN for application information. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-10 Effective 7/1/12 14-1011-28 Split System Cooling Three Phase – 6-25 Tons, R-410A TTA – 6-25 Tons • ReliaTel™ controls option • (1) Scroll compressor (TTA073-120D) • (2) Scroll compressors (TTA120E-240E) with independent refrigerant circuits • (2) Manifolded scroll compressors (TTA120F, 180F-300F) • Single point power • Compressor motor overload protection • Compressor discharge temperature limit switch • Control transformer • High and low pressure cut-out switches • Liquid line filter drier, factory installed • Service valves with pressure taps • Electrical phase reversal protection • Internal pressure relief valves • Holding charge (Dry Nitrogen) • Copper tube, aluminum plate fin coils • Low ambient cooling to 50°F as shipped • Low ambient cooling to 0°F with accessory head pressure control • Mounting/lifting rails under base • UL listed • 5-year compressor warranty (TTA073-120D/TTA120-180E/ TTA120-180F) • 1-year compressor warranty (TTA240E,F, TTA300F) • 1-year limited parts warranty • Optional Extended Warranties 1 2 3 4 5 6 7 8 9 10 11 12 T T A 0 9 0 D 3 0 0 A 0 1 2 3 4 5 6 7 8 9 10 11 12 T T A 0 9 0 D 3 0 0 A 0 Compressor Type Compressor Type D = Single Compressor/Single Refrigerant Circuit, R-410A D = Single Compressor/Single Refrigerant Circuit, R-410A E = Dual Compressor/Dual Refrigerant Circuit, R-410A E = Dual Compressor/Dual Refrigerant Circuit, R-410A F = Dual Compressor/Single Manifolded Refrigerant Circuit, F = Dual Compressor/Single Manifolded Refrigerant Circuit, R-410A R-410A Factory-Installed Options Factory-Installed Options H0 = Hail Guard 00 = Packed Stock HS = Hail Guard and Black Epoxy Coated Coil 0S = Black Epoxy Coated Coil HR = Hail Guard and ReliaTel™ Controls 0R = ReliaTel™ Controls HT = Hail Guard and ReliaTel™ Controls with Black Epoxy Coated Coil 0T = ReliaTel™ Controls and Black Epoxy Coated Coil HU = Hail Guard and ReliaTel™ Controls with LonTalk® Communication 0U = ReliaTel™ Controls with LonTalk® Communication Interface (RLCI) Interface (RLCI) 0W = ReliaTel™ Controls with LonTalk® Communication Interface (RLCI) Table SC-11-A — TTA Split System Cooling — Single Compressor — R-410 Refrigerant HW = Hail Guard and ReliaTel™ Controls with LonTalk® Communication and Black Epoxy Coated Coil Nom. Cap. Uncrated Shipping Line Size Interface (RLCI) and Black Epoxy Coated Coil Model Number Power Supply CoolingDimensions(in.) (BTUH) H W L Weight Sound1 Max. ODOD (lbs.) Rating MCA* Fuse* GasLiq. TTA073D300A 208-230/3/60 75,000 393642 365 84 31.1 4011/8 TTA090D300A 208-230/3/60 92,000 393642 363 83 34.4 4513/8 TTA120D300A 208-230/3/60 120,000 394052 467 90 42.6 6013/8 1 /2 /8 1 /2 TTA073D400A 460/3/60 TTA090D400A 460/3/60 TTA120D400A 460/3/60 75,000 393642 365 84 14.9 2011/8 92,000 393642 363 83 17.7 2513/8 120,000 394052 467 90 23.4 3013/8 1 TTA073DW00A575/3/60 TTA090DW00A575/3/60 TTA120DW00A575/3/60 75,000 393642 365 84 11.1 1511/8 92,000 393642 363 83 14.5 2013/8 120,000 394052 467 90 17.5 2513/8 1 5 /2 /8 1 /2 5 /2 /8 1 /2 5 Table SC-11-B — TTA Split System Cooling — Dual Compressors with Two Sets of Refrigerant Circuits — R-410 Refrigerant Model Number Power Supply Nom. Cap. Uncrated CoolingDimensions(in.) (BTUH) H W L Shipping Line Size Weight Sound1 Max. ODOD (lbs.) Rating MCA* Fuse* GasLiq. TTA120E300A 208-230/3/60 TTA150E300A 208-230/3/60 TTA180E300A 208-230/3/60 TTA240E300A 208-230/3/60 119,000 150,000 180,000 254,000 394052 454052 454695 454695 510 543 850 970 91 41 4511/8 91 55.4 7011/8 93 66.3 8013/8 94 98 11013/8 TTA120E400A 460/3/60 TTA150E400A 460/3/60 TTA180E400A 460/3/60 TTA240E400A 460/3/60 119,000 150,000 180,000 254,000 394052 454052 454695 454695 510 543 850 970 91 91 93 94 20.1 2511/8 26.4 3011/8 32.5 4013/8 46.9 6013/8 TTA120EW00A575/3/60 TTA150EW00A575/3/60 TTA180EW00A575/3/60 TTA240EW00A575/3/60 119,000 150,000 180,000 254,000 394052 454052 454695 454695 510 543 850 970 91 91 93 94 15.5 2011/8 21.4 2511/8 25.6 3013/8 38.7 4513/8 /2 /2 1 /2 1 /2 1 1 /2 /2 1 /2 1 /2 1 1 /2 /2 1 /2 1 /2 1 1 1 Sound rating show is tested in accordance with AHRI Standard 270 or 370. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-11 Effective 7/1/12 14-1011-28 Split System Cooling Three Phase – 6-25 Tons, R-410A TTA – 6-25 Tons • ReliaTel™ controls option • (1) Scroll compressor (TTA073D-120D) • (2) Scroll compressors (TTA120D-240E) with independent refrigerant circuits • (2) Manifolded scroll compressors (TTA120F, 180-240F) • Single point power • Compressor motor overload protection • Compressor discharge temperature limit switch • Control transformer • High and low pressure cut-out switches • Liquid line filter drier, factory installed • Service valves with pressure taps • Electrical phase reversal protection • Internal pressure relief valves • Holding charge (Dry Nitrogen) • Copper tube, aluminum plate fin coils • Low ambient cooling to 50°F as shipped • Low ambient cooling to 0°F with accessory head pressure control • Mounting/lifting rails under base • UL listed • 5-year compressor warranty (TTA073-120D/TTA120-180E/ TTA120-180F) • 1-year compressor warranty (TTA240E,F) • 1-year limited parts warranty • Optional Extended Warranties 1 2 3 4 5 6 7 8 9 10 11 12 T T A 0 9 0 D 3 0 0 A 0 1 2 3 4 5 6 7 8 9 10 11 12 T T A 0 9 0 D 3 0 0 A 0 Compressor Type Compressor Type D = Single Compressor/Single Refrigerant Circuit, R-410A D = Single Compressor/Single Refrigerant Circuit, R-410A E = Dual Compressor/Dual Refrigerant Circuit, R-410A E = Dual Compressor/Dual Refrigerant Circuit, R-410A F = Dual Compressor/Single Manifolded Refrigerant Circuit, F = Dual Compressor/Single Manifolded Refrigerant Circuit, R-410A R-410A Factory-Installed Options Factory-Installed Options H0 = Hail Guard 00 = Packed Stock HS = Hail Guard and Black Epoxy Coated Coil 0S = Black Epoxy Coated Coil ™ HR = Hail Guard and ReliaTel™ Controls 0R = ReliaTel Controls HT = Hail Guard and ReliaTel™ Controls with Black Epoxy Coated Coil 0T = ReliaTel™ Controls and Black Epoxy Coated Coil HU = Hail Guard and ReliaTel™ Controls with LonTalk® Communication 0U = ReliaTel™ Controls with LonTalk® Communication Interface (RLCI) Interface (RLCI) 0W = ReliaTel™ Controls with LonTalk® Communication Interface (RLCI) ™ ® Table SC-12-A TTACoated Split System Cooling — Dual Manifolded Compressors Refrigerant Circuits — R-410 Refrigerant HW = Hailwith GuardSingle and ReliaTel Controls with LonTalk Communication and Black — Epoxy Coil Nom. Cap. Uncrated Shipping Line Size Interface (RLCI) and Black Epoxy Coated Coil Model Number Power Supply CoolingDimensions(in.) (BTUH) H W L Weight Sound1 Max. ODOD (lbs.) Rating MCA* Fuse* GasLiq. TTA120F300A TTA180F300A TTA240F300A TTA300F300A 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 120,000 180,000 246,000 292,000 394052 509 454595 852 454595 966 514595 1112 91 44.6 5013/8 93 66.3 8015/8 94 98 11015/8 94 130.615021/8 1 TTA120F400A TTA180F400A TTA240F400A TTA300F400A 460/3/60 460/3/60 460/3/60 460/3/60 120,000 180,000 246,000 292,000 394052 509 454595 852 454595 966 514595 1112 91 93 94 94 24.1 3013/8 32.5 4015/8 49.6 6015/8 51.6 6021/8 1 TTA120FW00A575/3/60 TTA180FW00A575/3/60 TTA240FW00A575/3/60 TTA300FW00A575/3/60 120,000 180,000 246,000 292,000 394052 509 454595 852 454595 966 514595 1112 91 93 94 94 15.7 2013/8 26.3 3015/8 39.6 4515/8 40.9 4521/8 1 /2 /8 5 /8 5 /8 5 /2 /8 5 /8 5 /8 5 /2 /8 5 /8 5 /8 5 1 Sound rating show is tested in accordance with AHRI Standard 270 or 370. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-12 Effective 7/1/12 14-1011-28 Split System Cooling – R-410A Accessories Three Phase – 6-25 Tons Table SC-13-A — R-410A Optional Accessories Model Number Coil Guard BAYGARD058A BAYGARD059A BAYGARD060A BAYGARD061A BAYGARD062A Hot Gas By-Pass BAYHGBP010A Isolators BAYISLT004A BAYISLT005A BAYISLT009A BAYISLT010A BAYISLT023A BAYISLT024A BAYISLT025A Low Ambient BAYLOAMU01A1234 BAYLOAMU02A234 BAYLOAM335A3 BAYLOAM336A3 BAYLOAM435A3 BAYLOAM436A3 BAYLOAMW36A3 BAYLOTR001A5 Time Delay Relay BAYRLAY002 Description Used With Hail/Vandal Guard Hail/Vandal Guard Hail/Vandal Guard Hail/Vandal Guard Hail/Vandal Guard TTA073D, TTA090D TTA120D/E/F TTA150E TTA180E/F, TTA240E/F TTA300F Universal Hot Gas Bypass Kit TTA073D-TTA300F Rubber Isolator Floor (blue) Rubber Isolator Floor (black) Rubber Isolator Floor (red) Rubber Isolator Floor (green) Steel Spring Isolator Floor (red) Steel Spring Isolator Floor (black) Steel Spring Isolator Floor (yellow) TTA073D-TTA090D TTA120D/E/F TTA150E, TTA180E/F TTA240E/F, TTA300F TTA073D, TTA090D, TTA120D TTA120E/F, TTA150E, TTA180E/F TTA240E/F, TTA300F On/Off Fan Control Mounted in External Enclosure (small cabinets) On/Off Fan Control Mounted in Unit Control Box (large cabinets) Modulating ICM Head Pressure Control w/ 208-230V 0.5 HP Hi-Eff Motor (internal mount) Modulating ICM Head Pressure Control w/ 208-230V 1 HP Hi-Eff Motor (internal mount) Modulating ICM Head Pressure Control w/ 460V 0.5 HP Hi-Eff Motor (internal mount) Modulating ICM Head Pressure Control w/ 460V 1.0 HP Hi-Eff Motor (internal mount) Modulating ICM Head Pressure Control w/ 575V 1.0 HP Hi-Eff Motor (internal mount) Additional Pressure Transducer for ICM Head Pressure Control TTA073-090 (all voltages) Time Delay Relay TTA090D-TTA300F TTA120-300 (all voltages) TTA073D3, TTA090D3 TTA120D3/E3/F3, TTA150E3, TTA180E3/F3, TTA240E3/F3, TTA300F3 TTA073D4, TTA090D4 TTA120D4/E4/F4, TTA150E4, TTA180E4/F4, TTA240E4/F4, TTA300F4 TTA120DW/EW/FW, TTA150EW, TTA180EW/FW, TTA240EW/FW, TTA300FW TTA120E/F, TTA150E 1Kit mounts external to the outdoor unit and operates by sensing ambient and liquid line temperatures. 2Cycles fan on/off, (no modulating). 3Quantity of 1 required for each fan (2 total for TTA/TWA180-300). 4ReliaTel™ requires onboard EDC function to be disabled when Bayloam is used, remove OA sensor from terminal J8-1&2. 5BAYLOTR001A required when modulating BAYLOAM kits used with units that have 2 compressors and 1 condenser fan. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-13 Effective 7/1/12 14-1011-28 Split System Cooling Three Phase – 6-25 Tons Table SC-14-A — ReliaTel™ Control Options Model Number Description ASYSTAT106A ASYSTAT107a ASYSTAT108a ASYSTAT109a ASYSTAT777a BAYSENS0501 BAYSENS073A BAYSENS074A BAYSENS077A BAYSENS110A Zone Sensor, Set Point, Fan System Tta073-Tta300 with ReliaTel™ Controls Zone Sensor, Set Point Adj, Fan, System, EH, LED TTa073-TTa300 Zone Sensor, 2 Set Point, Fan System Tta073-Tta300 with ReliaTel™ Controls Zone Sensor, 2 Set Point Adj, Fan, System, EH, LEDTTa073-TTa300 Digital Programmable Zone Sensor with Night Setback Tta073-Tta300 with ReliaTel™ Controls Wireless Zone Sensor TTA073-TTA300 with ReliaTel™ Controls Room Sensor w/ Override and Cancel Button TTA073-TTA300 with ReliaTel™ Controls Room Sensor w/ Temperature TTA073-TTA300 with ReliaTel™ Controls Adjustment and Override Button Remote Sensor ASYSTAT106A-ASYSTAT109A, ASYSTAT777A Dual Set Point w/ Manual/Auto Change Over TTA073-TTA300 with ReliaTel™ Controls Used With Table SC-14-B — Electromechanical Control Options Model Number Description ASYSTAT092A ASYSTAT093A 2H/2C Touch Screen Digital Display Programmable Thermostat "Touch Screen" 3H/2C Digital Display Programmable Thermostat W/Humidity Sensor Used With All All 1Kit comes with everything required for installation and operation. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-14 Effective 7/1/12 14-1011-28 6 - 25 Tons with ReliaTel™ Controls TTA073-120D, TTA120-240E, TTA120-300F Protection/Operation Timings and Features Anti Short Cycle Timer (ASCT) Function — Provides a three (3) minute minimum “ON” time and a three (3) minute minimum “OFF” time for compressors, enhances compressor reliability by ensuring proper oil return. Standard On Board Diagnostics1 — Assist with equipment troubleshooting, if a problem occurrence should take place. Standard Built In Fan Delay Relay (FDR) Function — Provides custom indoor fan timing sequences for the different types of equipment, enhancing efficiency and reliability. Standard Built In Night Set Back and Unoccupied Functions1 — When using a standard dual setpoint/auto change over Zone Sensor Module (ZSM), this function is enabled by applying a short across terminal J6-11 and J6-12. Sets cooling setpoint up a minimum of 7°F, sets heating setpoint back a minimum of 7°F, and forces fan operation to automatic. (requires time clock accessory or field supplied/ installed switch or contacts). Built In “TEST” Mode — Aids in quick verification of system and control operation, exercises both hardware and software (no special tools required). Standard Remote Sensing1 — All standard Zone Sensor Modules (ZSMs) have remote sensing capabilities, typically achieved by using an expensive program-mable thermostat and remote sensor with electromechanical equipment. Accessory (requires use of remote sensor). Space Temperature Averaging1 — All standard Zone Sensor Modules (ZSMs) have space temperature averaging capabilities, typically achieved by using an expensive programmable thermostat and minimum of four (4) remote sensors with electromechanical equipment. Averaging with ReliaTel™ can be achieved with two (2) sensors. Time Delay Relay (TDR) Function — Provides an incremental staging delay between compressors, minimizes equipment current inrush and consumption by keeping compressors from starting simultaneously. Standard Low Pressure and High Pressure Compressor Lockout — 3 trips will lockout control. Built In Unoccupied Mode1 — When using a standard single setpoint/manual change over Zone Sensor Module (ZSM), this function is enabled by applying a short across terminal J6-11 and J6-12. Forces fan operation to automatic. (requires time clock accessory or field supplied/installed switch or contacts.) When the ReliaTel™ RTRM Thermostat Interface is used, equipment operation differs significantly. The basic equipment protection features remain intact, and the following features and benefits are lost: Direct Digital Control (DDC)1 — Proportional Integral (PI) control. Proportional – sets corrective action proportional to deviation from setpoint. Integral – fine tunes the rate of corrective action proportional to the error (results in superior space temperature control). Standard • Direct Digital Control (DDC) – Proportional Integral (PI) control is lost, equipment is controlled by a thermostat or generic building automation system device. • Intelligent Fall back is lost, if a failure occurs in the device controlling the equipment, operation will cease. • Installation is more costly, with the addition of a thermostat or generic control, the control wiring size must be increased. Increased Reliability — Fewer components (moving electromechanical parts), less likelihood of equipment down time or failure. Standard • Remote Sensing capabilities are lost, unless generic control being applied can accomplish this. Integral Electric Heat Staging1 — Stages electric heaters “OFF” and “ON”, eliminating the use of outdated sequencers. Standard Intelligent Fallback1 — A built in Default Control provides adaptive operation, which allows the equipment to continue to operate, providing comfort in the event of certain component failures. Also, allows emergency operation without a Zone Sensor Module (ZSM). Standard • Space Temperature Averaging capabilities are lost, unless generic control being applied can accomplish this. • Built In Night Set Back and Unoccupied functions are lost, unless generic control being applied can accomplish this. • Built In Unoccupied Mode is lost, unless generic control being applied can accomplish this. Low Ambient Start Timer (LAST) Function — Bypasses low pressure control when a compressor starts, eliminating nuisance compressor lock outs. Standard Lower Installation Cost — Using a standard Zone Sensor Module (ZSM), control voltage wiring may be run up to five (5) times further than any electromechanical system, with no increase in wire gauge. Example: Electromechanical System – 30 feet maximum using 22 gauge wire. Micro Control System – 150 feet using 22 gauge wire. Standard 1 Denotes features lost from utilizing standard conventional stat. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SC-15 Effective 7/1/12 14-1011-28 Split System Heat Pumps Single Phase – 1½-5 Tons Table SH-1-A — Platinum ZM Heat Pump (Previously Heritage 20) — with AccuLink™123 Model Number Power Supply Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) Rating MCA* Fuse* GasLiq. 4A6Z0024A1000C 4A6Z0036B1000A 4A6Z0048B1000B 4A6Z0060A1000C 200/230/1/60 208/230/1/60 208/230/1/60 200/230/1/60 24,000 36,000 48,000 60,000 45 45 45 45 37 37 37 37 34 34 34 34 380 385 470 470 70 72 76 76 14 20 26 31 20 30 40 50 /8 /4 3 /4 3 /4 /8 /8 3 /8 3 /8 5 3 3 3 Platinum ZM (4A6Z0) Table SH-1-B — Platinum XM Heat Pump (Previously Heritage 16) Model Number Power Supply Nom. Cap. Uncrated Shipping Line Size (in) CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) Rating MCA* Fuse* GasLiq. 4A6H6024G1000A 208/230/1/6024,000 4A6H6036G1000A 208/230/1/6036,000 4A6H6048G1000B 208/230/1/6048,000 4A6H6060E1000A 208/230/1/6060,000 41 37 45 37 45 37 45 37 34 34 34 34 305 307 329 330 72 72 73 74 14 22 28 39 20 5/8 35 3/4 45 7/8 60 11/8 /8 /8 3 /8 3 /8 3 3 Platinum XM (4A6H6) Table SH-1-C — Gold XI Heat Pump (Previously Heritage 15) Model Power Number Suppy Gold XI (4A6H5) Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 4A6H5018G1000A 208/230/1/60 18,000 4A6H5024G1000A 208/230/1/60 24,000 4A6H5030G1000A 208/230/1/60 30,000 4A6H5036G1000A 208/230/1/60 36,000 4A6H5042G1000A 208/230/1/6041,500 4A6H5049E1000A 208/230/1/6048,000 4A6H5061E1000A 208/230/1/60 60,000 29 33 33 33 33 37 33 37 37 37 45 37 45 37 30 30 34 34 34 34 34 204 240 281 261 278 331 332 75 75 75 75 75 75 75 9 11 15 18 23 28 36 15 15 25 30 40 50 60 /8 /8 3 /4 3 /4 3 /4 7 /8 11/8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 5 3 5 3 1Must use ACONT900 or AZONE950 control with communicating systems. 2BAYACHP024A required for 24 volt mode. 3Because of limited capabilities, please refer to the product ratings for approved combinations. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Rated in accordance with AHRI Standard 270-2008. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SH-1 Effective 7/1/12 14-1011-28 Split System Heat Pumps Single Phase – 1½-5 Tons Table SH-2-A — Features (4A6Z0)(4A6H6)(4A6H5) • • • • • • • • • • • • • • • • • • • • • • • • • SEER up to............................................................................................................................................................. 19.00 17.50 16.00 HSPF up to.............................................................................................................................................................. 10.00 9.00 9.50 Duration™ compressor.......................................................................................................................................... 2 1 ✔ Number of stages.................................................................................................................................................... 2 2 1 AccuLink™ system................................................................................................................................................ ✔ — — Charge Assist™ fast/accurate charging every time.............................................................................................. ✔ — — Comfort-R™ mode approved................................................................................................................................. ✔ ✔ ✔ DuraBase™ base, fast complete drain, weatherproof........................................................................................... ✔ ✔ ✔ Easy-Sess™ cabinet, service access & refrigerant connections with full coil protection...................................... ✔ ✔ ✔ Spine Fin™ coil...................................................................................................................................................... ✔ ✔ ✔ Demand Defrost Control w/Lite Port™/Stored Diagnostics................................................................................... — — ✔ Electronic Expansion Valve (EEV).......................................................................................................................... ✔ ✔— Compressor sound enclosure................................................................................................................................. ✔ — ✔ Compressor sump heat - factory installed.............................................................................................................. ✔ ✔ ✔ Factory supplied charge ......................................................................................................................................... R-410A R-410A R-410A Glossy corrosion resistant finish............................................................................................................................. ✔ ✔ ✔ High pressure switch............................................................................................................................................... ✔ ✔ ✔ Low pressure switch................................................................................................................................................ ✔ ✔ — Liquid line filter drier - factory installed.................................................................................................................... ✔ ✔ ✔ Quick start kit - factory installed.............................................................................................................................. ✔ —1½-3,5 Seacoast shield - factory installed.......................................................................................................................... ✔ ✔ ✔ Spinnaker gray cabinet............................................................................................................................................ ✔ ✔ ✔ 12-year registered limited warranty on compressor, 10-year on outdoor coil & all other functional parts (Residential Use)3................................................................................................................ ✔ ✔ — 10-year registered limited warranty on compressor, outdoor coil & all other functional parts (Residential Use)3................................................................................................................. — — ✔ Extended warranties available ............................................................................................................................ ✔ ✔ ✔ Table SH-2-B — Optional Accessories Model Number Description Shipping Weight AY28X084....................Evaporator Defrost Control...................................................1............................................... — BAYACHP024A............24 Volt Wiring Harness..........................................................1............................................... ✔ BAYCAKT001...............Charge Assist™ Solenoid Kit..............................................3............................................... ✔ BAYECMT023..............Extreme Conditions Mounting Kit (Base 2/3)........................2............................................... — BAYECMT004 .............Extreme Conditions Mounting Kit (Base 4)...........................2............................................... ✔ BAYINS001..................Insulation Kit........................................................................................................................... — BAYISLT101.................Rubber Isolators....................................................................1............................................... ✔ BAYKSKT260 ..............Start kit (Scroll) ....................................................................1............................................... — BAYLEGS002 ..............Snow Legs - Base and Cap 6" High (Black).........................1............................................... ✔ BAYLEGS003...............4" extension (Black) .............................................................1............................................... ✔ BAYLOAM103..............Low Ambient Kit....................................................................1............................................... — TAYASCT501A12 .....Anti-Short Cycle Timer .........................................................2............................................... — TAYPLUS103A.............Heat Pump Control Kit..........................................................3............................................... — PAI003095..................Heresite Spraypaint...............................................................1............................................... ✔ — ✔ — — — — — — ✔ ✔ — ✔ ✔ ✔ 2-53½-4 ✔ ✔ ✔ ✔ — ✔5 — ✔ — ✔ ✔ ✔ Comfort Controls — See Comfort Controls/Zone Sensors Section 1 Do not use with programmable thermostats. 2Activated on Power Off. 3Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. 4For operation to 20ºF outdoor ambient. 5Used for additional seacoast corrosion protection. Refer to bulletin number UN-SVB11A-EN for application information. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SH-2 Effective 7/1/12 14-1011-28 Split System Heat Pumps Single Phase – 1½-5 Tons Table SH-3-A— Gold SI Heat Pump (Previously Heritage 13) Model Power Number Suppy Gold SI (4A6H3-B) 4A6H3018C1000A 4A6H3024C1000A 4A6H3030C1000A 4A6H3036B1000A 4A6H3042B1000A 4A6H3048B1000A 4A6H3060B1000A Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 208/230/1/6019,000 208/230/1/6024,000 200/230/1/6029,400 208/230/1/6034,800 208/230/1/6041,500 208/230/1/6047,000 208/230/1/6057,500 29 33 29 33 33 33 33 37 33 37 37 37 41 37 30 30 30 34 34 34 34 189 191 221 261 253 269 284 76 75 76 75 75 75 75 9 12 15 18 26 28 34 15 20 25 30 45 50 60 /8 /8 3 /4 3 /4 3 /4 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 5 3 5 3 Table SH-3-B— Silver XI Heat Pump (Previously American Standard 14) Model Power Number Suppy Silver XI (4A6B4) 4A6B4018G1000A 4A6B4024G1000A 4A6B4030G1000A 4A6B4036G1000A 4A6B4042G1000A 4A6B4049E1000B 4A6B4061E1000A Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 208/230/1/6018,000 208/230/1/6024,000 208/230/1/6030,000 208/230/1/6036,000 208/230/1/6041,500 208/230/1/6048,000 208/230/1/6060,000 29 33 33 33 33 37 33 37 37 37 45 37 45 37 30 30 34 34 34 34 34 204 236 273 261 278 331 332 76 76 78 76 76 76 76 9 11 15 18 23 28 36 15 15 25 30 40 50 60 /8 /8 3 /4 3 /4 3 /4 7 /8 11/8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 5 3 5 3 Table SH-3-C— Silver SI Heat Pump (Previously American Standard 13) Model Power Number Suppy Silver SI (4A6B3) 4A6B3018B1000A 4A6B3024B1000A 4A6B3030B1000A 4A6B3036B1000A 4A6B3042B1000A 4A6B3048B1000A 4A6B3060B1000A Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 208/230/1/6017,000 208/230/1/6023,000 208/230/1/6028,500 208/230/1/6034,500 208/230/1/6040,500 208/230/1/6046,500 208/230/1/6058,500 29 33 29 33 33 33 33 37 33 37 37 37 41 37 30 30 30 34 34 34 34 201 204 221 261 253 269 284 79 81 80 79 80 78 78 9 12 15 18 26 28 34 15 20 25 30 45 50 60 /8 /8 3 /4 3 /4 3 /4 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 5 3 5 3 Phasing Out * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Rated in accordance with AHRI Standard 270-2008. Table SH-3-D — Silver SI Heat Pump (Previously American Standard 13) Silver SI (4TWB3) Model Number Power Supply Nom. Cap. UncratedShipping Line Size (in) CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D(lbs.) Rating MCA* Fuse* GasLiq. 4TWB3018C1000A 4TWB3024C1000A 4TWB3030C1000A 4TWB3036B1000B 4TWB3042B1000B 4TWB3048B1000B 4TWB3060B1000B 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 17,000 23,000 28,500 34,500 40,500 46,500 58,500 29 33 29 33 33 33 33 37 33 37 37 37 41 37 30189 30191 30221 34261 34253 34269 34284 79 81 80 79 80 78 78 9 12 15 18 26 28 34 15 20 25 30 45 50 60 /8 /8 3 /4 3 /4 3 /4 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 5 3 5 3 * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Rated in accordance with AHRI Standard 270-2008. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SH-3 Effective 7/1/12 14-1011-28 Split System Heat Pumps Single Phase – 1½-5 Tons Table SH-4-A — Features • • • • • • • • • • • • • • • • • • • PHasING out (4A6H3) (4A6B4)(4A6B3) (4TWB3) SEER up to.......................................................................................................................................... 14.50 15.00 14.00 14.00 HSPF up to........................................................................................................................................... 8.50 9.00 8.50 8.50 Duration™ compressor....................................................................................................................... ✔ ✔ ✔ ✔ Comfort-R™ mode approved.............................................................................................................. ✔ ✔ ✔ ✔ DuraBase™ base, fast complete drain, weatherproof........................................................................ ✔ ✔ ✔ ✔ Easy-Sess™ cabinet, service access & refrigerant connections with full coil protection................... ✔ ✔ ✔ ✔ Spine Fin™ coil................................................................................................................................... ✔ ✔ ✔ ✔ Compressor sump heat - factory installed........................................................................................... — ✔— — Demand Defrost Control w/Lite Port™/Stored Diagnostics................................................................ ✔ ✔ ✔ ✔ Quick start kit-factory installed ............................................................................................................ 1½-3,5 1½-3,5 1½-3 1½-3 Low Pressure Switch............................................................................................................................ 3.5-5 3.5-5 3.5-53.5-5 Factory supplied charge ...................................................................................................................... R-410A R-410A R-410A R-410A Glossy corrosion resistant finish.......................................................................................................... ✔ ✔ ✔ ✔ High pressure switch............................................................................................................................ ✔ ✔ ✔ ✔ Liquid line filter drier - factory installed................................................................................................. ✔ ✔ ✔ ✔ Polyslate gray cabinet.......................................................................................................................... — ✔ ✔ ✔ Spinnaker gray cabinet......................................................................................................................... ✔ —— — 10-year registered limited warranty on compressor, outdoor coil & all other functional parts (Residential Use)3...................................................... ✔ ✔ ✔ ✔ Extended warranties available ......................................................................................................... ✔ ✔ ✔ ✔ Table SH-4-B — Optional Accessories Model Number Description Shipping Weight PHasing out AY28X084....................Evaporator Defrost Control................................... 1............................................ ✔ ✔ ✔ ✔ BAYCCHT300..............Crankcase Heater Kit (Reciprocating).................. 1............................................1½-3 1½-3 1½-3 1½-3 BAYCCHT301..............Crankcase Heater Kit (Scroll)............................... 1............................................3½-5 3½-5 3½-5 3½-5 BAYECMT023..............Extreme Conditions Mounting Kit (Base 2/3)........ 2............................................1½-2½ 1½-2½1½-2½ 1½-2½ BAYECMT004..............Extreme Conditions Mounting Kit (Base 4)........... 2............................................ 3-5 3-5 3-53-5 BAYINS001..................Insulation Kit........................................................................................................ ✔ ✔ ✔ ✔ BAYISLT101.................Rubber Isolators.................................................... 1............................................ ✔ ✔ ✔ ✔ BAYKSKT260 ..............Start kit (Scroll)..................................................... 1............................................3½-4 3½-5 3½-5 3½-5 BAYLEGS002A............Snow Legs Base and Cap 6" High (Black) .......... 1............................................ ✔ ✔ ✔ ✔ BAYLEGS003A............4" Extension (Black).............................................. 1............................................ ✔ ✔ ✔ ✔ BAYLOAM103..............Low Ambient Kit.................................................... 1............................................ ✔ ✔4 ✔ ✔ BAYSEAC001...............Seacoast Kit.......................................................... 1............................................ ✔ ✔ ✔ ✔ TAYASCT501A12......Anti-Short Cycle Timer.......................................... 2............................................ ✔ ✔ ✔ ✔ TAYPLUS103A.............Heat Pump Control Kit.......................................... 3............................................ ✔ ✔ ✔ ✔ PAI003095..................Heresite Spraypaint............................................... 1............................................ ✔ ✔ ✔ ✔ Comfort Controls — See Comfort Controls/Zone Sensors Section 1Not for use with programmable thermostats. 2Activated on Power Off. 3Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. 4For operation to 20°F outdoor ambient. 5Used for additional seacoast corrosion protection. Refer to bulletin number UN-SVB11A-EN for application information. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SH-4 Effective 7/1/12 14-1011-28 R-22 Dry Ship Replacement Heat Pump Table SH-5-A — R-22 American Standard 13 Split System Heat Pump — Single Phase Model Power Number Suppy 2A6B3018A1000A 2A6B3024A1000A 2A6B3030A1000A 2A6B3036A1000A 2A6B3042A1000A American Standard 13 2A6B3048A1000A (2A6B3) 2A6B3060A1000A Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 200/230/1/6017,000 200/230/1/6023,000 200/230/1/6028,500 200/230/1/6034,500 200/230/1/6040,500 200/230/1/6046,500 208/230/1/6058,500 33 29 33 29 37 33 37 37 41 37 41 37 41 37 26 26 30 34 34 34 34 202 205 240 291 308 312 291 74 79 79 79 80 78 79 8 12 13 19 21 25 33 15 20 20 30 35 40 50 /8 1/4 /4 5/16 3 /4 5/16 7 /8 3/8 7 /8 3/8 1 1 /8 3/8 11/8 3/8 5 Phasing Out 3 * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Rated in accordance with AHRI Standard 270-2008. Table SH-5-B — Silver SI R-22 Split System Heat Pump (Previously American Standard 13) Model Power Number Suppy Silver SI (2TWB3) Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 2TWB3018A1000C208/230/1/6017,000 2TWB3024A1000C208/230/1/6023,000 2TWB3030A1000C208/230/1/6028,500 2TWB3036A1000C208/230/1/6034,500 2TWB3042A1000C208/230/1/6040,500 2TWB3048A1000C208/230/1/6046,500 2TWB3060A1000C208/230/1/6058,500 33 29 33 29 37 33 37 37 41 37 41 37 41 37 26 26 30 34 34 34 34 202 205 240 291 308 312 291 74 79 79 79 80 78 79 8 12 13 19 21 25 33 15 5/8 1/4 20 3/4 5/16 20 3/4 5/16 30 7/8 3/8 35 7/8 3/8 40 11/8 3/8 50 11/8 3/8 * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Rated in accordance with AHRI Standard 270-2008. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SH-5 Effective 7/1/12 14-1011-28 R-22 Dry Ship Replacement Heat Pump Table SH-6-A — Features • • • • • • • • • • • • • • • • • • (2TWB3) SEER up to................................................................................................................................................................................................ 13.25 HSPF up to................................................................................................................................................................................................. 8.0 Duration™ compressor............................................................................................................................................................................. ✔ Comfort-R™ mode approved.................................................................................................................................................................... ✔ DuraBase™ base, fast complete drain, weatherproof.............................................................................................................................. ✔ Easy-Sess™ cabinet, service access & refrigerant connections with full coil protection......................................................................... ✔ Spine Fin™ coil......................................................................................................................................................................................... ✔ Compressor sound enclosure.................................................................................................................................................................... 3-4 Compressor sump heat - factory installed................................................................................................................................................. — Refrigerant - (R-22 not factory supplied).................................................................................................................................................... R-22 Glossy corrosion resistant finish................................................................................................................................................................ ✔ Low pressure switch................................................................................................................................................................................... ✔ Internal high / low pressure & temperature protection............................................................................................................................... ✔ Liquid line filter drier - factory installed....................................................................................................................................................... ✔ Polyslate gray cabinet................................................................................................................................................................................ ✔ Start kit - factory installed........................................................................................................................................................................... 1½-4 5-year registered limited warranty on compressor, 1-year on outdoor coil & all other functional parts (Residential Use)3..... ✔ Extended warranties available ............................................................................................................................................................... ✔ Table SH-6-B — Optional Accessories Model Number Description Shipping Weight AY28X084...................Evaporator Defrost Control HP..............................................1................................................................................. ✔ BAYCCHT300.............Crankcase Heater Kit (Recip)................................................1................................................................................. 1½-4 BAYCCHT302.............Crankcase Heater Kit (Scroll)................................................1................................................................................. 5 BAYECMT023.............Extreme Conditions Mounting Kit (Base 2/3).........................2................................................................................. 1½-2½ BAYECMT004.............Extreme Conditions Mounting Kit (Base 4)............................2................................................................................. 3-5 BAYISLT101................Rubber Isolators.....................................................................1................................................................................. ✔ BAYKSKT260..............Start Kit (Scroll)......................................................................1................................................................................. 5 BAYLEGS002..............Snow Legs - Base and Cap 6" High (Black)..........................1................................................................................. ✔ BAYLEGS003..............4" Extension (Black)...............................................................1................................................................................. ✔ BAYLOAM103.............Low Ambient Kit.....................................................................1................................................................................. ✔ BAYSDEN001.............Single Cylinder Compressor Enclosures...............................8................................................................................. 1½-2½ BAYSDEN004.............Large Scroll Compressor Enclosures....................................8................................................................................. 5 BAYSEAC001..............Seacoast Kit ..........................................................................1................................................................................. ✔ TAYASCT501A12.....Anti-short cycle timer.............................................................2................................................................................. ✔ PAI003095.................Heresite Spraypaint................................................................1................................................................................. ✔ Comfort Controls — See Comfort Controls/Zone Sensors Section 1 Do not use with programmable thermostats. 2 Activated on Power Off. 3Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. 4For operation to 20°F outdoor ambient. 5Used for additional seacoast corrosion protection. Refer to bulletin number UN-SVB11A-EN for application information. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SH-6 Effective 7/1/12 14-1011-28 Split System Heat Pumps Three Phase – 2½-5 Tons Table SH-7-A — Silver SI Heat Pump (Previously American Standard 13) Silver SI (4A6C3) Model Power Number Suppy Nom. Cap. Uncrated Shipping Line Size CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D (lbs.) RatingMCA*Fuse* GasLiq. 4A6C3030A3000B 4A6C3036A3000B 4A6C3042A3000B 4A6C3048A3000B 4A6C3060A3000B 30,000 36,000 42,000 48,000 60,000 37 37 37 41 41 30,000 36,000 42,000 48,000 60,000 37 33 30 37 37 34 37 37 34 4137 34 41 37 34 200/230/3/60 200/230/3/60 200/230/3/60 200/230/3/60 200/230/3/60 33 37 37 37 37 30 34 34 34 34 233 264 269 277 297 80 79 80 78 78 11 16 18 21 24 15 25 30 35 40 231 263 268 276 296 80 79 80 78 78 5 7 9 9 12 15 15 15 15 20 /4 /4 3 /4 7 /8 7 /8 3 3 /16 /8 3 /8 3 /8 3 /8 5 3 Phasing Out 4A6C3030A4000B 460/3/60 4A6C3036A4000B 460/3/60 4A6C3042A4000B 460/3/60 4A6C3048A4000B 460/3/60 4A6C3060A4000B 460/3/60 /4 /4 3 /4 7 /8 7 /8 /16 /8 3 /8 3 /8 3 /8 3 5 3 3 * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Rated in accordance with AHRI Standard 270-2008. Table SH-7-B — Silver SI Heat Pump (Previously American Standard 13) Model Number Silver SI (4TWA3) 4TWA3030A3000C 4TWA3036A3000C 4TWA3042B3000C 4TWA3048B3000C 4TWA3060B3000C 4TWA3030A4000C 4TWA3036A4000C 4TWA3042B4000C 4TWA3048B4000C 4TWA3060B4000C Power Supply Nom. Cap. UncratedShipping Line Size (in) CoolingDimensions(in.) Weight Sound** Max. OD OD (BTUH) H W D(lbs.) Rating MCA* Fuse* GasLiq. 200/230/3/60 200/230/3/60 208/230/3/60 208/230/3/60 208/230/3/60 30,000 36,000 40,500 46,500 58,500 37 37 33 37 41 33 37 37 37 37 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 30,000 36,000 40,500 46,500 58,500 37 33 37 37 33 37 37 37 41 37 30 34 34 34 34 233 264 248 263 280 30 231 34 263 34 248 34 263 34280 80 79 80 78 78 11 16 18 18 20 15 25 30 30 35 3 /4 /4 3 /4 7 /8 7 /8 3 3 3 /8 /8 3 /8 3 /8 3 /8 80 79 80 78 78 5 7 8 8 10 15 15 15 15 15 3 /4 /4 3 /4 7 /8 7 /8 3 3 3 /8 /8 3 /8 3 /8 3 /8 * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Rated in accordance with AHRI Standard 270-2008. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SH-7 Effective 7/1/12 14-1011-28 Split System Heat Pumps Three Phase – 2½-5 Tons Table SH-8-A — Features (4A6C3)(4TWA3) SEER up to............................................................................................................................................................................. 13.00 13.00 HSPF up to.............................................................................................................................................................................. 8.50 8.50 Duration™ compressor.......................................................................................................................................................... ✔ ✔ Comfort-R™ mode approved................................................................................................................................................. ✔ ✔ DuraBase™ base, fast complete drain, weatherproof........................................................................................................... ✔ ✔ Easy-Sess™ cabinet, service access & refrigerant connections with full coil protection...................................................... ✔ ✔ Spine Fin™ coil...................................................................................................................................................................... ✔ ✔ Compressor sump heat - factory installed.............................................................................................................................. ✔ ✔ Demand Defrost Control w/Lite Port™/Stored Diagnostics................................................................................................... ✔ ✔ Factory supplied charge ......................................................................................................................................................... R-410A R-410A Glossy corrosion resistant finish............................................................................................................................................. ✔ ✔ Liquid line filter drier - factory installed.................................................................................................................................... ✔ ✔ Low pressure switch................................................................................................................................................................ ✔ ✔ Internal high / low pressure & temperature protection............................................................................................................ ✔ ✔ Polyslate gray cabinet............................................................................................................................................................. ✔ ✔ 5-year registered limited warranty on compressor, outdoor coil & 1-year on all other functional parts (Commercial Use) ................................................................................................................... ✔ ✔ 5-year registered limited warranty on compressor, outdoor coil & 5-year on all other functional parts (Residential Use) ..................................................................................................................... ✔ ✔ Extended warranties available ............................................................................................................................................ ✔ ✔ PHasing out • • • • • • • • • • • • • • • • • • Table SH-8-B — Optional Accessories Model Number Description Shipping Weight PHasing out AY28X084....................Evaporator defrost control.....................................................1.............................................................. ✔ ✔ BAYECMT023..............Extreme Conditions Mounting Kit (Base 2/3)........................2.............................................................. 2½ 2½ BAYECMT004..............Extreme Conditions Mounting Kit (Base 4)...........................2.............................................................. 3-53-5 BAYINS001..................Insulation Kit.......................................................................................................................................... ✔ ✔ BAYISLT101.................Rubber Isolators....................................................................1.............................................................. ✔ ✔ BAYLEGS002...............Snow Legs - Base and Cap - 6" (Black)...............................1.............................................................. ✔ ✔ BAYLEGS003...............4" Extension (used with BAYLEGS002) (Black)...................1.............................................................. ✔ ✔ BAYLOAM103..............Low Ambient Kit....................................................................1.............................................................. ✔ ✔ BAYSEAC001...............Seacoast Kit..........................................................................1.............................................................. ✔ ✔ TAYASCT501A12 .....Anti-Short Cycle Timer..........................................................2.............................................................. ✔ ✔ PAI003093..................Heresite Spraypaint...............................................................1.............................................................. ✔ ✔ Comfort Controls — See Comfort Controls/Zone Sensors Section 1Do not use with programmable thermostats. 2Activated on Power Off. 3Used for additional seacoast corrosion protection. Refer to bulletin number UN-SVB11A-EN for application information. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SH-8 Effective 7/1/12 14-1011-28 Split System Heat Pumps Three Phase – 6-20 Tons, R-410A TWA – 6-20 Tons • ReliaTel™ controls (standard) • (1) Scroll compressor (TWA073-120D) • (2) Scroll compressors (TWA180-240E) with independent refrigerant circuits • Single point power • Compressor motor overload protection • Compressor discharge temperature limit switch • Control transformer • High and low pressure cut-out switches • Liquid line filter drier, factory installed • Service valves with pressure taps • Demand Defrost Control • Internal pressure relief valves • Electrical phase reversal protection • Holding charge (Dry Nitrogen) • Copper tube, aluminum plate fin coils • Low ambient cooling to 50°F as shipped • Low ambient cooling to 0°F with accessory head pressure control • Mounting/lifting rails under base • UL listed • 5-year compressor warranty (TWA073D, TWA090D, TWA120D, TWA180E) • 1-year compressor warranty (TWA240E) • 1-year limited parts warranty • Optional Extended Warranties 1 2 3 4 5 6 7 8 9 10 11 12 T W A 0 9 0 D 3 0 0 A 0 1 2 3 4 5 6 7 8 9 10 11 12 T W A 0 9 0 D 3 0 0 A 0 Compressor Type D = Single Compressor/Single Refrigerant Circuit, R-410A E = Dual Compressor/Dual Refrigerant Circuit, R-410A Factory-Installed Options HR = Hail Guard and ReliaTel™ Controls HT = Hail Guard and ReliaTel™ Controls with Black Epoxy Coated Coil HU = Hail Guard and ReliaTel™ Controls with LonTalk® Communication Interface (RLCI) HW = Hail Guard and ReliaTel™ Controls with LonTalk® Communication Interface (RLCI) and Black Epoxy Coated Coil Compressor Type D = Single Compressor/Single Refrigerant Circuit, R-410A E = Dual Compressor/Dual Refrigerant Circuit, R-410A Factory-Installed Options 0R = ReliaTel™ Controls 0T = ReliaTel™ Controls and Black Epoxy Coated Coil 0U = ReliaTel™ Controls with LonTalk® Communication Interface (RLCI) 0W = ReliaTel™ Controls with LonTalk® Communication Interface (RLCI) and Black Epoxy Coated Coil Table SH-9-A — TWA Split System Heat Pumps — Single Compressors with Single Refrigerant Circuits — R-410 Refrigerant Model Number Power Supply Nom. Cap. Uncrated CoolingDimensions(in.) (BTUH) H W L Shipping Line Size (in) Weight Sound1 Max. ODOD (lbs.) Rating MCA* Fuse* GasLiq. TWA073D30RA208-230/3/60 78,000 393642 382 84 31.1 4011/8 TWA090D30RA208-230/3/60 90,000 393642 394 83 34.4 4513/8 TWA120D30RA208-230/3/60 120,000 454052 509 90 42.6 6013/8 1 /2 /8 1 /2 TWA073D40RA460/3/60 TWA090D40RA460/3/60 TWA120D40RA460/3/60 78,000 393642 382 84 14.9 2011/8 90,000 393642 394 83 17.9 2513/8 120,000 454052 509 90 23.4 3013/8 1 TWA073DW0RA 575/3/60 TWA090DW0RA 575/3/60 TWA120DW0RA 575/3/60 78,000 393642 382 84 11.6 1511/8 90,000 393642 394 83 14.7 2013/8 120,000 454052 509 90 17.4 2513/8 1 5 /2 /8 1 /2 5 /2 /8 1 /2 5 Table SH-9-B — TWA Split System Heat Pumps — Dual Compressors with Two Sets of Refrigerant Circuits — R-410 Refrigerant Model Number Power Supply Nom. Cap. Uncrated CoolingDimensions(in.) (BTUH) H W L Shipping Line Size (in) Weight Sound1 Max. ODOD (lbs.) Rating MCA* Fuse* GasLiq. TWA180E30RA208-230/3/60 180,000 464595 898 93 66.3 8013/8 TWA240E30RA208-230/3/60 246,000 464595 981 94 86.110013/8 TWA180E40RA460/3/60 TWA240E40RA460/3/60 180,000 464595 898 93 33.4 4013/8 246,000 464595 981 94 45.5 5013/8 TWA180EW0RA 575/3/60 TWA240EW0RA 575/3/60 180,000 464595 898 93 27.4 3013/8 246,000 464595 981 94 34.8 4013/8 1 5 /2 /8 /2 /8 1 5 /2 /8 1 5 1 Sound rating show is tested in accordance with AHRI Standard 270 or 370. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SH-9 Effective 7/1/12 14-1011-28 Split System Heat Pumps – Accessories Three Phase – 6-20 Tons, R-410A Table SH-10-A — R-410A Optional Accessories Model Number Description Used With Coil Guard BAYGARD058A Hail/Vandal Guard BAYGARD060A Hail/Vandal Guard BAYGARD061A Hail/Vandal Guard Isolators BAYISLT005A Rubber Isolator Floor (black) BAYISLT009A Rubber Isolator Floor (red) BAYISLT010A Rubber Isolator Floor (green) BAYISLT023A Steel Spring Isolator Floor (red) BAYISLT024A Steel Spring Isolator Floor (black) BAYISLT025A Steel Spring Isolator Floor (yellow) Low Ambient BAYLOAMU01A123 On/Off Fan Control Mounted in External Enclosure (small cabinets) BAYLOAMU02A23 On/Off Fan Control Mounted in Unit Control Box (large cabinets) BAYLOAM335A34 Modulating ICM Head Pressure Control w/ 208-230V 0.5 HP Hi-Eff Motor (internal mount) BAYLOAM336A34 Modulating ICM Head Pressure Control w/ 208-230V 1 HP Hi-Eff Motor (internal mount) BAYLOAM435A34 Modulating ICM Head Pressure Control w/ 460V 0.5 HP Hi-Eff Motor (internal mount) BAYLOAM436A34 Modulating ICM Head Pressure Control w/ 460V 1.0 HP Hi-Eff Motor (internal mount) BAYLOAMW36A34 Modulating ICM Head Pressure Control w/ 575V 1.0 HP Hi-Eff Motor (internal mount) Time Delay Relay BAYRLAY002 Time Delay Relay BAYRLAY005 Heat Pump interlock relay Wire Kit BAYWRKT003A5 Heat Pump configuration wiring harness TWA 073D,090D TWA120D TWA180E,240E TWA073D-TWA120D TWA180E TWA240E TWA073D, TWA090D, TWA120D TWA180E TWA240E TWA073D-090D (all voltages) TWA120D-240E (all voltages) TWA073D, TWA090D3 TWA120D3 TWA073D4, TWA090D4 TWA120D4 TWA120DW TWA090D-TWA240E All TWA Units with Bayloam Application Requirements TWA180E, TWA240E 1Kit mounts external to the outdoor unit and operates by sensing ambient and liquid line temperatures. 2Cycles fan on/off, (no modulating). 3Quantity of 1 required for each fan (2 total for TTA/TWA180-240). 4Heat pumps require BAYRLAY005 when modulating BAYLOAM kits are selected. 5Used on Dual circuit HP condensers with a field installed LCI card for independent mechanical heating operation configuration. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SH-10 Effective 7/1/12 14-1011-28 Split System Heat Pumps Three Phase – 6-20 Tons Table SC-11-A — ReliaTel™ Control Options Model Number Description Used With ASYSTAT107A Zone Sensor, Set Point Adj, Fan, System, EH, LED ASYSTAT109A Zone Sensor, 2 Set Point Adj, Fan, System, EH, LED ASYSTAT777A Digital Programmable Zone Sensor with Night Setback BAYSENS0501 Wireless Zone Sensor BAYSENS073A Room Sensor w/ Override and Cancel Button BAYSENS074A Room Sensor w/ Temperature Adjustment and Override Button BAYSENS077A Remote Sensor BAYSENS110A Dual Set Point w/ Manual/Auto Change Over TWA073-TWA240 with ReliaTel™ Controls TWA073-TWA240 with ReliaTel™ Controls TWA073-TWA240, TTA073-TTA240 with ReliaTel™ Controls TWA073-TWA240 with ReliaTel™ Controls TWA073-TWA240 with ReliaTel™ Controls TWA073-TWA240 with ReliaTel™ Controls ASYSTAT107A, ASYSTAT109A, ASYSTAT777A TWA073-TWA240 with ReliaTel™ Controls Table SC-11-B — Electromechanical Control Options Model Number Description ASYSTAT092A ASYSTAT093A 2H/2C Touch Screen Digital Display Programmable Thermostat "Touch Screen" 3H/2C Digital Display Programmable Thermostat W/Humidity Sensor Used With All All 1Kit comes with everything required for installation and operation. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SH-11 Effective 7/1/12 14-1011-28 6 - 20 Tons with ReliaTel™ Controls TWA073,TWA090,TWA120, TWA180,TWA240 Protection/Operation Timings and Features Anti Short Cycle Timer (ASCT) Function — Provides a three (3) minute minimum “ON” time and a three (3) minute minimum “OFF” time for compressors, enhances compressor reliability by ensuring proper oil return. Standard Built In Fan Delay Relay (FDR) Function — Provides custom indoor fan timing sequences for the different types of equipment, enhancing efficiency and reliability. Standard Built In Night Set Back and Unoccupied Functions1 — When using a standard dual setpoint/auto change over Zone Sensor Module (ZSM), this function is enabled by applying a short across terminal J6-11 and J6-12. Sets cooling setpoint up a minimum of 7°F, sets heating setpoint back a minimum of 7°F, and forces fan operation to automatic. (requires time clock accessory or field supplied/ installed switch or contacts). Built In “TEST” Mode — Aids in quick verification of system and control operation, exercises both hardware and software (no special tools required). Standard Built In Unoccupied Mode1 — When using a standard single setpoint/manual change over Zone Sensor Module (ZSM), this function is enabled by applying a short across terminal J6-11 and J6-12. Forces fan operation to automatic. (requires time clock accessory or field supplied/installed switch or contacts.) Direct Digital Control (DDC)1 — Proportional Integral (PI) control. Proportional – sets corrective action proportional to deviation from setpoint. Integral – fine tunes the rate of corrective action proportional to the error (results in superior space temperature control). Standard Increased Reliability — Fewer components (moving electromechanical parts), less likelihood of equipment down time or failure. Standard Integral Electric Heat Staging1 — Stages electric heaters “OFF” and “ON”, eliminating the use of outdated sequencers. Standard Intelligent Fallback1 — A built in Default Control provides adaptive operation, which allows the equipment to continue to operate, providing comfort in the event of certain component failures. Also, allows emergency operation without a Zone Sensor Module (ZSM). Standard Low Ambient Start Timer (LAST) Function — Bypasses low pressure control when a compressor starts, eliminating nuisance compressor lock outs. Standard On Board Diagnostics1 — Assist with equipment troubleshooting, if a problem occurrence should take place. Standard Remote Sensing1 — All standard Zone Sensor Modules (ZSMs) have remote sensing capabilities, typically achieved by using an expensive program-mable thermostat and remote sensor with electromechanical equipment. Accessory (requires use of remote sensor). Space Temperature Averaging1 — All standard Zone Sensor Modules (ZSMs) have space temperature averaging capabilities, typically achieved by using an expensive programmable thermostat and minimum of four (4) remote sensors with electromechanical equipment. Averaging with ReliaTel™ can be achieved with two (2) sensors. Time Delay Relay (TDR) Function — Provides an incremental staging delay between compressors, minimizes equipment current inrush and consumption by keeping compressors from starting simultaneously. Standard Low Pressure and High Pressure Compressor Lockout — 3 trips will lockout control. When the ReliaTel™ RTRM Thermostat Interface is used, equipment operation differs significantly. The basic equipment protection features remain intact, and the following features and benefits are lost: • Direct Digital Control (DDC) – Proportional Integral (PI) control is lost, equipment is controlled by a thermostat or generic building automation system device. • Intelligent Fall back is lost, if a failure occurs in the device controlling the equipment, operation will cease. • Installation is more costly, with the addition of a thermostat or generic control, the control wiring size must be increased. • Remote Sensing capabilities are lost, unless generic control being applied can accomplish this. • Space Temperature Averaging capabilities are lost, unless generic control being applied can accomplish this. • Built In Night Set Back and Unoccupied functions are lost, unless generic control being applied can accomplish this. • Built In Unoccupied Mode is lost, unless generic control being applied can accomplish this. Demand Defrost — Defrosts only if needed, not based on time like most other systems, optmizing and lowering operating costs. Lower Installation Cost — Using a standard Zone Sensor Module (ZSM), control voltage wiring may be run up to five (5) times further than any electromechanical system, with no increase in wire gauge. Example: Electromechanical System – 30 feet maximum using 22 gauge wire. Micro Control System – 150 feet using 22 gauge wire. Standard 1 Denotes features lost from utilizing standard conventional stat. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. SH-12 Effective 7/1/12 14-1011-28 Multi-position Air Handler * Note: No internal modifications required for any position. 1 Badge rotation will keep brand in correct position Airflow 1 Refrigerant Connections Refrigerant Connections Upflow Condensate Drains 1 Airflow Downflow Condensate Drains Vertical Downflow* Vertical Upflow* (as shipped) Refrigerant Connections Refrigerant Connections 1 Airflow 1 Airflow Horizontal Right Condensate Drains Horizontal Left Condensate Drains Horizontal Right* Horizontal Left* For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-1 Effective 7/1/12 14-1011-28 Features and Benefits 1 Unique Cabinet Design 2 Precision Applied 5Conduit Durable Door Seals 0 Electronic Expansion Connection Locations Valve (EEV) 3 Refrigeration Connections e Integrated Horizontal Drain Pans 8 All Aluminum Coil 4Condensate Connections 6 Alert Code Viewport r Safety Door Switch 7 VorticaTM Blower 9 Labeled Panels and Connections w Compact 20.8” Depth with q Maximum width is Doors Removed 23.5” 8 All Aluminum Coil - Integrated Slide Deck for Easy Removal - Polarized Plug connections on Coil EEV - Patented Enhanced Coil Fin 9 Labeled Panels and Connections 0 Electronic Expansion Valve (EEV) - Low Ambient and Low Superheat Compressor Protection - Dual Refrigerant Compatible as Shipped q Maximum width is 23.5” w Compact 20.8” Depth with Doors Removed e Integrated Horizontal Drain Pans r Safety Door Switch - Fused 24V Power t Modular Cabinet 1 Unique Cabinet Design - Double wall foamed cabinet system - Waterproof Cabinet Design (No Thermal Breakage) - ≥ R-4.2 Insulating Value (Avg. Insulating Value R-8.2) - Composite Foamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Design - Smooth Cleanable Cabinet Design 2 Precision Applied Durable Door Seals 3 Refrigeration Connections 4 Condensate Connections 5 Conduit Connection Locations - Dimples in cabinet mark Conduit Connection Locations for Left, Right, and Top 6 Alert Code Viewport - Alert Codes can be Viewed Without Door Removal - Control Protection Pocket 7 VorticaTM Blower - Polarized Plug Connections - Integrated Slide Deck for Easy Removal For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-2 Effective 7/1/12 14-1011-28 Series 8 Variable Speed Multi-Position Air Handlers 2-5 Tons Table AH-3-A — AccuLink™ Variable Speed R-410A with Smart Fan Options 200-230/1/60 Cooling Unit Capacity Model No. (Btuh) TAM8A0A24V21CB TAM8A0B30V21CB TAM8A0C36V31CB TAM8A0C42V31CB TAM8A0C48V41CB TAM8A0C60V51CB TAM8B0C60V51CA 24000 30000 36000 42000 48000 60000 60000 Dimensions (in.) H x W x D Shipping Weight (Ibs.) Supply Opening Return Opening Filter Sizes 49.9x 17.5x 21.8 55.7x 21.3x 21.8 56.9x 23.5x 21.8 56.9x 23.5x 21.8 61.7x 23.5x 21.8 61.7x 23.5x 21.8 61.7x 23.5x 21.8 126 150 157 162 174 175 175 14.5x 14.35 18.4x 14.35 20.5x 14.35 20.5x 14.35 20.5x 14.35 20.5x 14.35 20.5x 14.35 14.5x 17.15 18.4x 17.15 20.5x 17.15 20.5x 17.15 20.5x 17.15 20.5x 17.15 20.5x 17.15 16x20x1 20x20x1 22x20x1 22x20x1 22x20x1 22x20x1 22x20x1 Line Size GasLiquid /4 /4 7 /8 7 /8 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 3 3 Series 7 Variable Speed Multi-Position Air Handlers 2-5 Tons Table AH-3-B — Variable Speed R-410A with Comfort-R™ Enhanced Mode Option 200-230/1/60 Cooling Unit Capacity Model No. (Btuh) TAM7A0A24H21SB TAM7A0B30H21SB TAM7A0C36H31SB TAM7A0C42H31SB TAM7A0C48H41SB TAM7A0C60H51SB TAM7B0C60H51SA 24000 30000 36000 42000 48000 60000 60000 Dimensions (in.) H x W x D Shipping Weight (Ibs.) Supply Opening Return Opening Filter Sizes 49.9x 17.5x 21.8 55.7x 21.3x 21.8 56.9x 23.5x 21.8 56.9x 23.5x 21.8 61.7x 23.5x 21.8 61.7x 23.5x 21.8 61.7x 23.5x 21.8 126 150 157 162 174 175 175 14.5x 14.35 18.4x 14.35 20.5x 14.35 20.5x 14.35 20.5x 14.35 20.5x 14.35 20.5x 14.35 14.5x 17.15 18.4x 17.15 20.5x 17.15 20.5x 17.15 20.5x 17.15 20.5x 17.15 20.5x 17.15 16x20x1 20x20x1 22x20x1 22x20x1 22x20x1 22x20x1 22x20x1 Line Size GasLiquid /4 /4 7 /8 7 /8 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 3 3 Note: 1st digit change from A to T and 14th digit change from A to B represent a color change only. A model revisions should be ordered as long as available. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-3 Effective 7/1/12 14-1011-28 Series 7 & 8 Variable Speed Multi-Position Air-Tite™ Air Handlers TAM7 TAM8 Table AH-4-A — Features 2-52-5 • Unique cabinet design ................................................................................................................................................................... ✔ – 2% or less air leakage.................................................................................................................................................................. ✔ – Precision applied - durable door seals......................................................................................................................................... ✔ – Specially designed air seal around refrigerant, condensate and conduit connections ............................................................... ✔ – Double wall foamed cabinet system............................................................................................................................................. ✔ – ≥ R-4.2 insulating value (Avg. Insulating Value R-8.2)................................................................................................................. ✔ – No loose fiber design................................................................................................................................................................... ✔ – Smooth cleanable interior design................................................................................................................................................. ✔ – Sweat eliminating design............................................................................................................................................................ ✔ – Composite foamed cabinet doors................................................................................................................................................ ✔ – Water proof cabinet design ......................................................................................................................................................... ✔ – Integrated horizontal drain pans.................................................................................................................................................. ✔ – Modular cabinet ........................................................................................................................................................................... ✔ • Multi-position up/down flow horizontal left/right.............................................................................................................................. ✔ • Side return option (sold as accessory)........................................................................................................................................... ✔ • Control board protection pocket built into cabinet wall.................................................................................................................... ✔ • Alert port to view control board codes without door removal.......................................................................................................... ✔ • AccuLink™ control........................................................................................................................................................................ — • Alert code notification...................................................................................................................................................................... ✔ • 5 button user interface and clear description of set up...................................................................................................................— • Service diagnostic with alert reported at user interface ................................................................................................................. — • Low voltage terminal connection point............................................................................................................................................ ✔ • Vortica® blower with polarized plug connections and integrated slide deck for easy removal....................................................... ✔ • Aluminum coil with integrated slide deck for easy removal and polarized plug connections on coil eev...................................... ✔ • Patented enhanced coil fin.............................................................................................................................................................. ✔ • Electronic Expansion Valve (eev) with low ambient and low superheat compressor protection................................................... ✔ • Dual refrigerant compatible as shipped.......................................................................................................................................... ✔ • Slide in electric heaters with polarized plug connections (sold as accessory)............................................................................... ✔ • Slide in hot water coils with polarized plug connections (sold as accessory)................................................................................. ✔ • uvc light kit with safety switch and polarized plug connections (sold as accessory).................................................................... ✔ • Labeled panels and connections.................................................................................................................................................... ✔ • Molded in 1" standard filter rail ....................................................................................................................................................... ✔ • Variable speed ECM motor............................................................................................................................................................. ✔ • Soft start fan motor operation......................................................................................................................................................... ✔ • Comfort R™ mode......................................................................................................................................................................... ✔ • Built in fan delay modes.................................................................................................................................................................. ✔ • Maximum width of 23.5".................................................................................................................................................................. ✔ • Compact 20.8" depth with doors removed...................................................................................................................................... ✔ • Fused 24v power............................................................................................................................................................................. ✔ • Safety door switch........................................................................................................................................................................... ✔ • 10-year warranty registered......................................................................................................................................................... ✔ • Optional extended warranty available........................................................................................................................................ ✔ For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-4 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Effective 7/1/12 14-1011-28 Series 7 & 8 Variable Speed Multi-Position Air-Tite™ Air Handlers Table AH-5-A — Optional Accessories Model Number Description Matches Cabinet Size(s)1 TAM7TAM8 BAYCC24VK01A.................. Compressor Module Kit....................................................................................................................... — BAYWVAA05SC1AA............ Hydronic Heater, 40,000 BTUH, Nominal, Slide-in, RS-485 Control3..............A............................... ✔ BAYWVBB07SC1AA............ Hydronic Heater, 50,000 BTUH, Nominal, Slide-in, RS-485 Control3..............B............................... ✔ BAYWVCC08SC1AA........... Hydronic Heater, 65,000 BTUH, Nominal, Slide-in, RS-485 Control3............. C............................... ✔ BAYWACC11SC1AA............ Hydronic Heater, 100,000 BTUH, Nominal, External, No Control3................. C............................... ✔ BAYWVBRD485................... RS-485 Control for BAYWACC11SC1AA.......................................................... C............................... ✔ BAYSUPFLGAA................... Supply Duct Flange A.........................................................................................A............................... ✔ BAYSUPFLGBA................... Supply Duct Flange B.........................................................................................B............................... ✔ BAYSUPFLGCA................... Supply Duct Flange C........................................................................................ C............................... ✔ BAYRETFLGAA................... Return Duct Flange A.........................................................................................A............................... ✔ BAYRETFLGBA................... Return Duct Flange B.........................................................................................B............................... ✔ BAYRETFLGCA................... Return Duct Flange C........................................................................................ C............................... ✔ TASB175SB25.................. Plenum Stand with Integrated Sound Baffle A...................................................A............................... ✔ TASB215SB25.................. Plenum Stand with Integrated Sound Baffle B...................................................B............................... ✔ TASB235SB25.................. Plenum Stand with Integrated Sound Baffle C.................................................. C............................... ✔ MTISRKIT16202................. Side Return Kit with 16"x20" Filter....................................................................A-C............................. ✔ TASSBK17524.................. Sound Baffle Kit 17.5" Cabinet...........................................................................A............................... ✔ TASSBK21524.................. Sound Baffle Kit 21.5" Cabinet.......................................................................... B............................... ✔ TASSBK23524.................. Sound Baffle Kit 23.5" Cabinet.......................................................................... C............................... ✔ BAYSPEKT200..................... Single Power Entry Kit......................................................................................................................... ✔ BAYSRKIT100...................... Side Return Kit..................................................................................................................................... ✔ BAYICSKIT01....................... Internal Condensate Switch Kit........................................................................................................... ✔ BAYHHKIT001...................... Horizontal Hanger Kit........................................................................................................................... ✔ BAYUVCLK001.................... UVC Lights........................................................................................................................................... ✔ BAYLVKIT100....................... Low Voltage Conduit Entry Kit............................................................................................................. ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ 1A Cabinet is 17.5" wide, B Cabinet is 21.5" wide, C Cabinet is 23.5" wide. 2Contact your distributor for information. 3ACONT900 Thermostat can not be used with Hydronic heating. 4In return plenum applications, use TASSBK kits for sound reduction. 5In open air applications, Plenum Stand with Sound Baffle provides sound reduction. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-5 Effective 7/1/12 14-1011-28 Series 4 Multi-Position Air Handlers Single Phase 1½-5 Tons Table AH-6-A — Multi-Speed PSC Motor 200-230/1/60 Cooling Unit Capacity Model No. (Btuh) TAM4A0A18S11SB TAM4A0A24S21SB TAM4A0A30S21SB TAM4A0A36S31SB TAM4A0B42S31SB TAM4A0C48S41SB TAM4A0C60S51SB1 18000 24000 30000 36000 42000 48000 60000 Dimensions (in.) H x W x D Shipping Weight (Ibs.) Supply Opening Return Opening Filter Sizes 49.9x 17.5x 21.8 49.9x 17.5x 21.8 49.9x 17.5x 21.8 49.9x 17.5x 21.8 55.7x 21.3x 21.8 56.9x 23.5x 21.8 61.7x 23.5x 21.8 123 126 127 130 144 155 171 14.5x 14.35 14.5x 14.35 14.5x 14.35 14.5x 14.35 18.4x 14.35 18.4x 14.35 20.5x 14.35 14.5x 17.15 14.5x 17.15 14.5x 17.15 14.5x 17.15 18.4x 17.15 18.4x 17.15 20.5x 17.15 16x20x1 16x20x1 16x20x1 16x20x1 20x20x1 20x20x1 22x20x1 Line Size GasLiquid /4 /4 7 /8 7 /8 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 3 3 1High efficiency ECM motor. Note: 1st digit change from A to T and 14th digit change from A to B represent a color change only. A model revisions should be ordered as long as available. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-6 Effective 7/1/12 14-1011-28 Series 4 Multi-Position Air Handlers Single Phase 1½-5 Tons TAM4 Table AH-7-A — Features 1 1/2-5 • Unique cabinet design.................................................................................................................................................................................. ✔ – 2% or less air leakage................................................................................................................................................................................ ✔ – Precision applied - durable door seals....................................................................................................................................................... ✔ – Specially designed air seal around refrigerant, condensate and conduit connections ............................................................................. ✔ – Double wall foamed cabinet system........................................................................................................................................................... ✔ – ≥ r-4.2 insulating value (Avg. Insulating Value R-8.2)............................................................................................................................... ✔ – No loose fiber design................................................................................................................................................................................. ✔ – Smooth cleanable interior design............................................................................................................................................................... ✔ – Sweat eliminating design.......................................................................................................................................................................... ✔ – Composite foamed cabinet doors.............................................................................................................................................................. ✔ – Water proof cabinet design ....................................................................................................................................................................... ✔ – Integrated horizontal drain pans................................................................................................................................................................ ✔ – Modular cabinet.......................................................................................................................................................................................... ✔ • Multi-position up/down flow horizontal left/right............................................................................................................................................ ✔ • Side return option (sold as accessory)......................................................................................................................................................... ✔ • Control board protection pocket built into cabinet wall.................................................................................................................................. ✔ • Alert port to view control board codes without door removal........................................................................................................................ ✔ • Alert code notification.................................................................................................................................................................................... ✔ • Low voltage terminal connection point.......................................................................................................................................................... ✔ • Vortica® blower with polarized plug connections and integrated slide deck for easy removal..................................................................... ✔ • Aluminum coil with integrated slide deck for easy removal and polarized plug connections on coil eev.................................................... ✔ • Enhanced coil fin patented............................................................................................................................................................................ ✔ • Electronic Expansion Valve (eev) with low ambient and low superheat compressor protection................................................................. ✔ • Dual refrigerant compatible as shipped........................................................................................................................................................ ✔ • Slide in electric heaters with polarized plug connections (sold as accessory)............................................................................................. ✔ • uvc light kit with safety switch and polarized plug connections (sold as accessory).................................................................................. ✔ • Labeled panels and connections.................................................................................................................................................................. ✔ • Molded in 1" standard filter rail ..................................................................................................................................................................... ✔ • psc 3 speed motor....................................................................................................................................................................................... 1½-4 • High efficiency ECM motor........................................................................................................................................................................... 5 • Maximum width of 23.5"................................................................................................................................................................................ ✔ • Compact 20.8" depth with doors removed.................................................................................................................................................... ✔ • Fused 24v power........................................................................................................................................................................................... ✔ • Safety door switch......................................................................................................................................................................................... ✔ • 10-year warranty registered....................................................................................................................................................................... ✔ • Optional extended warranty available...................................................................................................................................................... ✔ Table AH-7-B — Optional Accessories Model Number Description Matches Cabinet Size(s)1TAM4 BAYSUPFLGAA................... Supply Duct Flange A.........................................................................................A............................................... BAYSUPFLGBA................... Supply Duct Flange B.........................................................................................B............................................... BAYSUPFLGCA................... Supply Duct Flange C........................................................................................ C............................................... BAYRETFLGAA................... Return Duct Flange A.........................................................................................A............................................... BAYRETFLGBA................... Return Duct Flange B.........................................................................................B............................................... BAYRETFLGCA................... Return Duct Flange C........................................................................................ C............................................... TASB175SB24.................. Plenum Stand with Integrated Sound Baffle A...................................................A............................................... TASB215SB24.................. Plenum Stand with Integrated Sound Baffle B...................................................B............................................... TASB235SB24.................. Plenum Stand with Integrated Sound Baffle C..................... ............................ C............................................... MTISRKIT16202................. Side Return Kit with 16"x20" Filter....................................................................A-C............................................. TASSBK17523.................. Sound Baffle Kit 17.5" Cabinet............................................. .............................A............................................... TASSBK21523.................. Sound Baffle Kit 21.5" Cabinet...........................................................................B............................................... TASSBK23523.................. Sound Baffle Kit 23.5" Cabinet.......................................................................... C............................................... BAYSPEKT200..................... Single Power Entry Kit......................................................................................................................................... BAYSRKIT100...................... Side Return Kit..................................................................................................................................................... BAYICSKIT01....................... Internal Condensate Switch Kit........................................................................................................................... BAYHHKIT001...................... Horizontal Hanger Kit........................................................................................................................................... BAYUVCLK001.................... UVC Lights........................................................................................................................................................... BAYLVKIT100A.................... Low Voltage Conduit Entry Kit............................................................................................................................. ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ 1A Cabinet is 17.5" wide, B Cabinet is 21.5" wide, C Cabinet is 23.5" wide. 2Contact your distributor for information. 3In return plenum applications, use TASSBK kits for sound reduction. 4In open air applications, Plenum Stand with Sound Baffle provides sound reduction. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-7 Effective 7/1/12 14-1011-28 Series 5 Multi-Position Air Handlers Single Phase 1½-5 Tons Table AH-8-A — Multi-Speed High Efficiency Motor 200-230/1/60 Cooling Unit Capacity Model No. (Btuh) GAM5A0A18M11SA GAM5A0A24M21SA GAM5A0B30M21SA GAM5A0B36M31SA GAM5A0C42M31SA GAM5A0C48M41SA GAM5A0C60M51SA 18000 24000 30000 36000 42000 48000 60000 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. Dimensions (in.) H x W x D Shipping Weight (Ibs.) Supply Opening Return Opening Filter Sizes 49.9x17.5x21.8 49.9x17.5x21.8 51.5x21.3x21.8 55.7x21.3x21.8 56.9x23.5x21.8 61.7x23.5x21.8 61.7x23.5x21.8 126 126 140 150 163 176 180 14.5x14.35 14.5x14.35 18.4x14.35 18.4x14.35 20.5x14.35 20.5x14.35 20.5x14.35 14.5x17.15 14.5x17.15 18.4x17.15 18.4x17.15 20.5x17.15 20.5x17.15 20.5x17.15 16x20x1 16x20x1 20x20x1 20x20x1 22x20x1 22x20x1 22x20x1 AH-8 Line Size GasLiquid /4 /4 3 /4 7 /8 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 3 3 Effective 7/1/12 14-1011-28 Series 5 Multi-Position Air Handlers Single Phase 1½-5 Tons GAM5 Table AH-9-A — Features 1 1/2-5 • Unique cabinet design.................................................................................................................................................................................. – 2% or less air leakage................................................................................................................................................................................ – Precision applied - durable door seals....................................................................................................................................................... – Specially designed air seal around refrigerant, condensate and conduit connections ............................................................................. – Double wall foamed cabinet system........................................................................................................................................................... – ≥ r-4.2 insulating value (Avg. Insulating Value R-8.2)............................................................................................................................... – No loose fiber design................................................................................................................................................................................. – Smooth cleanable interior design............................................................................................................................................................... – Sweat eliminating design.......................................................................................................................................................................... – Composite foamed cabinet doors.............................................................................................................................................................. – Water proof cabinet design ....................................................................................................................................................................... – Integrated horizontal drain pans................................................................................................................................................................ – Modular cabinet with 5/16" allen wrench "quick latch" design................................................................................................................... • Multi-position up/down flow horizontal left/right............................................................................................................................................ • Side return option (sold as accessory)......................................................................................................................................................... • Control board protection pocket built into cabinet wall.................................................................................................................................. • Alert port to view control board codes without door removal........................................................................................................................ • Alert code notification.................................................................................................................................................................................... • Low voltage terminal connection point.......................................................................................................................................................... • Vortica® blower with polarized plug connections and integrated slide deck for easy removal..................................................................... • Aluminum coil with integrated slide deck for easy removal and polarized plug connections on coil eev.................................................... • Patented enhanced coil fin............................................................................................................................................................................ • Electronic Expansion Valve (eev) with low ambient and low superheat compressor protection................................................................. • Dual refrigerant compatible as shipped........................................................................................................................................................ • Slide in electric heaters with polarized plug connections (sold as accessory)............................................................................................. • uvc light kit with safety switch and polarized plug connections (sold as accessory).................................................................................. • Labeled panels and connections.................................................................................................................................................................. • Molded in 1" standard filter rail ..................................................................................................................................................................... • High efficiency ECM motor........................................................................................................................................................................... • Maximum width of 23.5"................................................................................................................................................................................ • Compact 20.8" depth with doors removed.................................................................................................................................................... • Fused 24v power........................................................................................................................................................................................... • Safety door switch......................................................................................................................................................................................... • 10-year warranty registered....................................................................................................................................................................... • Optional extended warranty available...................................................................................................................................................... ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Table AH-9-B — Optional Accessories Model Number Description Matches Cabinet Size(s)1GAM5 BAYWAAA05SC1AA............ Hydronic Heater, 40,000 BTUH, Nominal, Slide-in, No Control.........................A............................................... BAYWABB07SC1AA............ Hydronic Heater, 50,000 BTUH, Nominal, Slide-in, No Control.........................B............................................... BAYWACC08SC1AA............ Hydronic Heater, 65,000 BTUH, Nominal, Slide-in, No Control........................ C............................................... BAYWACC11SC1AA............ Hydronic Heater, 100,000 BTUH, Nominal, Slide-in, No Control...................... C............................................... BAYSUPFLGAA................... Supply Duct Flange A.........................................................................................A............................................... BAYSUPFLGBA................... Supply Duct Flange B.........................................................................................B............................................... BAYSUPFLGCA................... Supply Duct Flange C........................................................................................ C............................................... BAYRETFLGAA................... Return Duct Flange A.........................................................................................A............................................... BAYRETFLGBA................... Return Duct Flange B.........................................................................................B............................................... BAYRETFLGCA................... Return Duct Flange C........................................................................................ C............................................... TASB175SB24.................. Plenum Stand with Integrated Sound Baffle A...................................................A............................................... TASB215SB24.................. Plenum Stand with Integrated Sound Baffle B...................................................B............................................... TASB235SB24.................. Plenum Stand with Integrated Sound Baffle C..................... ............................ C............................................... MTISRKIT16202................. Side Return Kit with 16"x20" Filter....................................................................A-C............................................. TASSBK17523.................. Sound Baffle Kit 17.5" Cabinet............................................. .............................A............................................... TASSBK21523.................. Sound Baffle Kit 21.5" Cabinet...........................................................................B............................................... TASSBK23523.................. Sound Baffle Kit 23.5" Cabinet.......................................................................... C............................................... BAYSPEKT200..................... Single Power Entry Kit......................................................................................................................................... BAYSRKIT100...................... Side Return Kit..................................................................................................................................................... BAYICSKIT01....................... Internal Condensate Switch Kit........................................................................................................................... BAYHHKIT001...................... Horizontal Hanger Kit........................................................................................................................................... BAYUVCLK001.................... UVC Lights........................................................................................................................................................... BAYLVKIT100A.................... Low Voltage Conduit Entry Kit............................................................................................................................. ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ 1A Cabinet is 17.5" wide, B Cabinet is 21.5" wide, C Cabinet is 23.5" wide. 2Contact your distributor for information. 3In return plenum applications, use TASSBK kits for sound reduction. 4In open air applications, Plenum Stand with Sound Baffle provides sound reduction. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-9 Effective 7/1/12 14-1011-28 Series 2 Split System Air Handlers Single Phase 1½-5 Tons Table AH-10-A — Multi-Speed PSC Motor 200-230/1/60 Cooling Unit Capacity Model No. (Btuh) GAF2A0A18S11SA GAF2A0A24S21SA GAF2A0A30S21SA GAF2A0A36S31SA 18000 24000 30000 36000 Dimensions (in.) H x W x D Shipping Weight (Ibs.) Supply Opening Return Opening Filter Sizes 39.5x17.5x21.8 39.5x17.5x21.8 39.5x17.5x21.8 39.5x17.5x21.8 117 120 121 122 14.5x14.35 14.5x14.35 14.5x14.35 14.5x14.35 14.5x17.15 14.5x17.15 14.5x17.15 14.5x17.15 N/A N/A N/A N/A Line Size GasLiquid /4 /4 3 /4 3 /4 /8 /8 3 /8 3 /8 3 3 3 3 Table AH-10-B — Multi-Speed PSC Motor 200-230/1/60 Cooling Unit Capacity Model No. (Btuh) GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA 42000 48000 60000 Dimensions (in.) H x W x D Shipping Weight (Ibs.) Supply Opening Return Opening Filter Sizes 55.7x21.3x21.8 56.9x23.5x21.8 61.7x23.5x21.8 144 155 171 18.4x14.35 18.4x14.35 20.5x14.35 18.4x17.15 18.4x17.15 20.5x17.15 20x20x1 20x20x1 22x20x1 Line Size GasLiquid /8 /8 7 /8 /8 /8 3 /8 7 3 7 3 Table AH-10-C — Multi-Speed High Efficiency ECM Motor 200-230/1/60 Cooling Unit Capacity Model No. (Btuh) GAF2A0A36M31SA 36000 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. Dimensions (in.) H x W x D Shipping Weight (Ibs.) Supply Opening Return Opening Filter Sizes 39.5x17.5x21.8 118 14.5x14.35 14.5x17.15 N/A AH-10 Line Size GasLiquid 3 /4 3 /8 Effective 7/1/12 14-1011-28 Series 2 Split System Air Handlers Single Phase 1½-5 Tons GAF2 GAT2 Table AH-11-A — Features 1 1/2-3 3 1/2-5 • Unique cabinet design................................................................................................................................................................. ✔ ✔ – 2% or less air leakage............................................................................................................................................................... ✔ ✔ – Precision applied - durable door seals...................................................................................................................................... ✔ ✔ – Specially designed air seal around refrigerant, condensate and conduit connections ............................................................ ✔ ✔ – Double wall foamed cabinet system.......................................................................................................................................... ✔ ✔ – ≥ r-4.2 insulating value (Avg. Insulating Value R-8.2).............................................................................................................. ✔ ✔ – No loose fiber design................................................................................................................................................................ ✔ ✔ – Smooth cleanable interior design.............................................................................................................................................. ✔ ✔ – Sweat eliminating design......................................................................................................................................................... ✔ ✔ – Composite foamed cabinet doors............................................................................................................................................. ✔ ✔ – Water proof cabinet design ...................................................................................................................................................... ✔ ✔ – Integrated horizontal drain pans............................................................................................................................................... ✔ ✔ • 3 way conversion up flow/horizontal left/right............................................................................................................................... ✔ ✔ • Front return option........................................................................................................................................................................ ✔— • Control board protection pocket built into cabinet wall................................................................................................................. ✔ ✔ • Low voltage terminal connection point......................................................................................................................................... ✔ ✔ ® • Vortica blower with polarized plug connections and integrated slide deck for easy removal.................................................... ✔ ✔ • Aluminum coil with integrated slide deck for easy removal and polarized plug connections on coil eev (GAF2A0A36M311SA)............................................................................................................................................................... 3 — • Patented enhanced coil fin........................................................................................................................................................... ✔ ✔ • R-410a txv................................................................................................................................................................................. ✔ ✔ • Slide in electric heaters with polarized plug connections (sold as accessory)............................................................................ — ✔ • uvc light kit with safety switch and polarized plug connections (sold as accessory)................................................................. — ✔ • Labeled panels and connections................................................................................................................................................. ✔ ✔ • Molded in 1" standard filter rail .................................................................................................................................................... — ✔ • psc 3 speed motor...................................................................................................................................................................... ✔ ✔ • High efficiency constant torque ECM motor (GAF2A0A36M311SA and GAT2A0C60S51SA)................................................... 3 5 • Maximum width of 23.5"............................................................................................................................................................... ✔ ✔ • Compact 20.8" depth with doors removed................................................................................................................................... ✔ ✔ • Fused 24v power.......................................................................................................................................................................... ✔ ✔ • Safety door switch........................................................................................................................................................................ ✔ ✔ • 10-year warranty registered...................................................................................................................................................... ✔ ✔ • Optional extended warranty available..................................................................................................................................... ✔ ✔ Table AH-11-B — Optional Accessories Model Number Description Matches Cabinet Size(s)13 GAF2GAT2 BAYATXV1836...............R-22 TXV conversion kit 1-1/2 to 3 ton...................................................................................................... ✔— BAYATXV4248...............R-22 TXV conversion kit 3-1/2 to 4 ton...................................................................................................... — ✔ BAYATXV6060...............R-22 TXV conversion kit 5 ton.................................................................................................................... — ✔ BAYSFSCABAA............Supply Duct Flange A1.............................................................................................A1............................. ✔ — BAYSUPFLGBA............Supply Duct Flange B................................................................................................B.............................. — ✔ BAYSUPFLGCA............Supply Duct Flange C............................................................................................... C.............................. — ✔ BAYRETFLGAA............Return Duct Flange A1.............................................................................................A1............................. ✔ — BAYRETFLGBA............Return Duct Flange B................................................................................................B.............................. — ✔ BAYRETFLGCA............Return Duct Flange C............................................................................................... C.............................. — ✔ TASB175SB25...........Plenum Stand with Integrated Sound Baffle A...........................................................A.............................. ✔ — TASB215SB25...........Plenum Stand with Integrated Sound Baffle B...........................................................B.............................. — ✔ TASB235SB25...........Plenum Stand with Integrated Sound Baffle C.......................................................... C.............................. — ✔ MTISRKIT16202..........Side Return Kit with 16"x20" Filter...........................................................................A-C............................ ✔ ✔ TASSBK17524...........Sound Baffle Kit 17.5" Cabinet...................................................................................A.............................. ✔ — TASSBK21524...........Sound Baffle Kit 21.5" Cabinet...................................................................................B.............................. — ✔ TASSBK23524...........Sound Baffle Kit 23.5" Cabinet.................................................................................. C.............................. — ✔ BAYSPEKT200..............Single Power Entry Kit................................................................................................................................ — ✔ BAYFRKIT100...............Front Return Kit.......................................................................................................................................... ✔— BAYBRFBX100.............Bottom Return Filter Box............................................................................................................................ ✔— BAYSRKIT100...............Side Return Kit........................................................................................................................................... — ✔ BAYICSKIT01................Internal Condensate Switch Kit.................................................................................................................. ✔ ✔ BAYWMKIT001.............Wall Mount Kit............................................................................................................................................ ✔— BAYHHKIT001...............Horizontal Hanger Kit................................................................................................................................. — ✔ BAYUVCLK001.............UVC Lights................................................................................................................................................. — ✔ BAYLVKIT100................Low Voltage Conduit Entry Kit.................................................................................................................... ✔ ✔ 1A1 Cabinet is 17.5" wide, B Cabinet is 21.5" wide, C Cabinet is 23.5" wide. 2Contact your distributor for information. 3The A1 cabinet is used on the GAF2 air handlers only. 4 In return plenum applications, use TASSBK kits for sound reduction. 5 In open air applications, Plenum Stand with Sound Baffle provides sound reduction. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-11 Effective 7/1/12 14-1011-28 Heaters for Multi-Position Air Handlers Table AH-12-A — BAYEA — Heater, Standard, for 4 Series, 5 Series, and GAT2 Air Handlers Heater Model Number BAYEAAC05BK1AA BAYEAAC05LG1AA BAYEAAC08BK1AA BAYEAAC08LG1AA BAYEAAC10BK1AA BAYEAAC10LG1AA BAYEABC15BK1AA BAYEABC20BK1AA BAYEACC25BK1AA Capacity Capacity @ 240 Volts @ 208 VoltsRated Control kW BTUH kW BTUH Voltage Stages 4.80 4.80 7.68 7.68 9.60 9.60 14.40 19.20 24.00 16400 16400 26200 26200 32800 32800 49200 65600 82000 3.6012300 3.6012300 5.7619700 5.7619700 7.2024600 7.2024600 10.8036900 14.4049200 18.0061500 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 1 1 2 2 2 2 3 4 5 Number Number of Heater of Racks Circuits 1 1 2 2 2 2 3 4 5 1 1 1 1 1 1 2 2 3 Heater Amps per Circuit 208 Volts 240Volt 17.3 17.3 27.7 27.7 34.6 34.6 34.6/17.3 34.6/34.6 34.6/34.6/17.3 20 20 32 32 40 40 40/20 40/40 40/40/20 Contains Circuit Breakers Yes No Yes No Yes No Yes Yes Yes BK = Contains circuit breakers LG = Contains lug connections Table AH-12-B — BAYEV — Heater, Standard, for 7 and 8 Series Air Handlers Heater Capacity Capacity Model @ 240 Volts @ 208 VoltsRated Control Number kW BTUH kW BTUH Voltage Stages BAYEVAC05BK1AA 4.80 16400 BAYEVAC05LG1AA 4.80 16400 BAYEVAC08BK1AA 7.68 26200 BAYEVAC08LG1AA 7.68 26200 BAYEVAC10BK1AA 9.60 32800 BAYEVAC10LG1AA 9.60 32800 BAYEVBC15BK1AA 14.40 49200 BAYEVBC20BK1AA 19.20 65600 BAYEVCC25BK1AA 24.00 82000 3.6012300 3.6012300 5.7619700 5.7619700 7.2024600 7.2024600 10.8036900 14.4049200 18.0061500 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 1 1 2 2 2 2 3 4 5 Number Number of Heater of Racks Circuits 1 1 2 2 2 2 3 4 5 1 1 1 1 1 1 2 2 3 Heater Amps per Circuit 208 Volts 240Volt 17.3 17.3 27.7 27.7 34.6 34.6 34.6/17.3 34.6/34.6 34.6/34.6/17.3 20 20 32 32 40 40 40/20 40/40 40/40/20 Contains Circuit Breakers Yes No Yes No Yes No Yes Yes Yes BK = Contains circuit breakers LG = Contains lug connections Table AH-12-C — BAYEC — Heater, Compact, with Lugs, for GAF2 Air Handlers Heater Capacity Capacity Model @ 240 Volts @ 208 VoltsRated Control Number kW BTUH kW BTUH Voltage Stages BAYECAA05LG1AA BAYECAA08LG1AA BAYECAA10LG1AA 4.80 16400 7.68 26200 9.60 32800 3.6012300 208/240/1/60 5.7619700 208/240/1/60 7.2024600 208/240/1/60 1 2 2 Number Number of Heater of Racks Circuits 1 2 2 1 1 1 Heater Amps per Circuit 208 Volts 240Volt 17.3 27.7 34.6 20 32 40 Contains Circuit Breakers No No No Table AH-12-D — BAYEV — Heater, 3-Phase, for 7 and 8 Series Air Handlers Heater Capacity Capacity Model @ 240 Volts @ 208 VoltsRated Control Number kW BTUH kW BTUH Voltage Stages BAYEVAC10LG3AA BAYEVBC15LG3AA 9.60 32800 14.40 49200 7.2024600 208/240/3/60 10.8036900 208/240/3/60 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. 1 1 AH-12 Number Number of Heater of Racks Circuits 3 3 1 1 Heater Amps per Circuit 240Volt 208 Volts 20.0 30.0 23.1 34.6 Contains Circuit Breakers No No Effective 7/1/12 14-1011-28 Heaters for Multi-Position Air Handlers Table AH-13-A — Air Handler/Heater Matrix AIR HANDLER MODEL NUMBER GAM5A0A18M11SA GAM5A0A24M21SA GAM5A0B30M21SA GAM5A0B36M31SA GAM5A0C42M31SA GAM5A0C48M41SA GAM5A0C60M51SA HEATER MODEL NUMBER BAYEAAC05BK1AA AC05LG1AA AC08BK1AA AC08LG1AA AC10BK1AA AC10LG1AA BC15BK1AA BC20BK1AA 4.80 Kw 4.80 Kw 7.68 Kw 7.68 Kw 9.60 Kw 9.60 Kw 14.40 Kw 19.20 Kw BK LG BK LG BK LG BK BK Y Y Y Y Y Y — — Y Y Y Y Y Y — — Y Y Y Y Y Y Y — Y Y Y Y Y Y Y — Y Y Y Y Y Y Y — Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y CC25BK1AA 24.00 Kw BK — — — — — Y Y TAM4A0A18S11SB TAM4A0A24S21SB TAM4A0A30S21SB TAM4A0A36S31SB TAM4A0B42S31SB TAM4A0C48S41SB TAM4A0C60S51SB Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y — Y Y Y Y Y Y — — — — Y Y Y — — — — — Y Y GAT2A0B42S31SA GAT2A0B48S41SA GAT2A0B48S4ASA GAT2A0C60S51SA GAT2A0C60S5ASA Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y — — — Y Y TAM8A0A24V21CB TAM8A0B30V21CB TAM8A0C36V31CB TAM8A0C42V31CB TAM8A0C48V41CB TAM8A0C60V51CB TAM8A0C61V51CB Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y — Y Y Y Y Y Y — — Y Y Y Y Y — — — — Y Y Y TAM7A0A24H21SB TAM7A0B30H21SB TAM7A0C36H31SB TAM7A0C42H31SB TAM7A0C48H41SB TAM7A0C60H51SB TAM7A0C61H51SB Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y — Y Y Y Y Y Y — — Y Y Y Y Y — — — — Y Y Y HEATER MODEL NUMBER BAYEV- AIR HANDLER MODEL NUMBER GAF2A0A18S11SA GAF2A0A24S21SA GAF2A0A30S21SA GAF2A0A36M31SA GAF2A0A36S31SA GAF2A0A36S3ASA AIR HANDLER HEATER MODEL NUMBER BAYECAA05LG1AA AA08LG1AA AA10LG1AA 4.80 Kw 7.68 Kw 9.60 Kw BK LG LG Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y BK = Contains circuit breakers LG = Contains lug connections BK = Contains circuit breakers LG = Contains lug connections For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. MODEL NUMBER TAM8A0A24V21CB TAM8A0B30V21CB TAM8A0C36V31CB TAM8A0C42V31CB TAM8A0C48V41CB TAM8A0C60V51CB TAM8A0C61V51CB TAM7A0A24H21SB TAM7A0B30H21SB TAM7A0C36H31SB TAM7A0C42H31SB TAM7A0C48H41SB TAM7A0C60H51SB TAM7A0C61H51SB AH-13 HEATER MODEL NUMBER BAYEVAC10LG3AA BC15LG3AA 9.60 Kw 14.4 Kw LG LG Y — Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y — Y Y Y Y Y Y Effective 7/1/12 14-1011-28 Silver Series Air Handlers Table AH-14-A — Convertible Air Handler Cooling Unit Capacity Model No. (Btuh) 4FWCA024A1000A 4FWCA025A1000A 4FWCA030A1000A 4FWCA031A1000A 4FWCA036A1000A 4FWCA048A1000A 4FWCA049A1000A 4FWCA060A1000A 4FWCA061A1000A Dimensions (in.) H x W x D 24000 45.0 x 19.75 x 21.5 24000 45.0 x 19.75 x 21.5 30000 45.0 x 19.75 x 21.5 30000 45.0 x 19.75 x 21.5 36000 45.0 x 19.75 x 21.5 48000 51.0 x 23.0 x 22.5 48000 51.0 x 23.0 x 22.5 60000 51.0 x 23.0 x 22.5 60000 51.0 x 23.0 x 22.5 Shipping Weight (Ibs.) Supply Opening Return Opening Filter Sizes 73 73 73 73 73 94 94 94 94 18.25 x 15.0 18.25 x 15.0 18.25 x 15.0 18.25 x 15.0 18.25 x 15.0 21.75 x 15.5 21.75 x 15.5 21.75 x 15.5 21.75 x 15.5 15.75 x 18.75 15.75 x 18.75 15.75 x 18.75 15.75 x 18.75 15.75 x 18.75 19 x 19.5 19 x 19.5 19 x 19.5 19 x 19.5 Remote* Remote* Remote* Remote* Remote* Remote* Remote* Remote* Remote* Line Size GasLiquid /4 /4 3 /4 3 /4 3 /4 7 /8 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 3 3 Table AH-14-B — Convertible Air Handler - R4.2 models Cooling Unit Capacity Model No. (Btuh) 4FWCF024A1000A 4FWCF025A1000A 4FWCF030A1000A 4FWCF031A1000A 4FWCF036A1000A 4FWCF048A1000A 4FWCF049A1000A 4FWCF060A1000A 4FWCF061A1000A Dimensions (in.) H x W x D 24000 45.0 x 19.75 x 21.5 24000 45.0 x 19.75 x 21.5 30000 45.0 x 19.75 x 21.5 30000 45.0 x 19.75 x 21.5 36000 45.0 x 19.75 x 21.5 48000 51.0 x 23.0 x 22.5 48000 51.0 x 23.0 x 22.5 60000 51.0 x 23.0 x 22.5 60000 51.0 x 23.0 x 22.5 Shipping Weight (Ibs.) Supply Opening Return Opening Filter Sizes 73 73 73 73 73 94 94 94 94 18.25 x 15.0 18.25 x 15.0 18.25 x 15.0 18.25 x 15.0 18.25 x 15.0 21.75 x 15.5 21.75 x 15.5 21.75 x 15.5 21.75 x 15.5 15.75 x 18.75 15.75 x 18.75 15.75 x 18.75 15.75 x 18.75 15.75 x 18.75 19 x 19.5 19 x 19.5 19 x 19.5 19 x 19.5 Remote* Remote* Remote* Remote* Remote* Remote* Remote* Remote* Remote* Line Size GasLiquid /4 /4 3 /4 3 /4 3 /4 7 /8 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 3 3 Table AH-14-C — Convertible Air Handler - Constant Torque ECM Motor Cooling Unit Capacity Model No. (Btuh) 4FWHA024A1000A 4FWHA025A1000A 4FWHA030A1000A 4FWHA036A1000A 4FWHA042A1000A 4FWHA048A1000A 4FWHA060A1000A 4FWHA061A1000A Dimensions (in.) H x W x D 24000 45.0 x 19.75 x 21.5 24000 45.0 x 19.75 x 21.5 30000 45.0 x 19.75 x 21.5 30000 45.0 x 19.75 x 21.5 42000 51.0 x 23.0 x 22.5 48000 51.0 x 23.0 x 22.5 60000 51.0 x 23.0 x 22.5 60000 51.0 x 23.0 x 22.5 Shipping Weight (Ibs.) Supply Opening Return Opening Filter Sizes 73 73 73 73 94 94 94 94 18.25 x 15.0 18.25 x 15.0 18.25 x 15.0 18.25 x 15.0 21.75 x 15.5 21.75 x 15.5 21.75 x 15.5 21.75 x 15.5 15.75 x 18.75 15.75 x 18.75 15.75 x 18.75 15.75 x 18.75 19 x 19.5 19 x 19.5 19 x 19.5 19 x 19.5 Remote* Remote* Remote* Remote* Remote* Remote* Remote* Remote* Line Size GasLiquid /4 /4 3 /4 3 /4 7 /8 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 3 3 Table AH-14-D — Convertible Air Handler - Constant Torque ECM Motor - R4.2 Models Cooling Unit Capacity Model No. (Btuh) 4FWHF024A1000A 4FWHF025A1000A 4FWHF030A1000A 4FWHF036A1000A 4FWHF042A1000A 4FWHF048A1000A 4FWHF060A1000A 4FWHF061A1000A Dimensions (in.) H x W x D 24000 45.0 x 19.75 x 21.5 24000 45.0 x 19.75 x 21.5 30000 45.0 x 19.75 x 21.5 36000 45.0 x 19.75 x 21.5 42000 51.0 x 23.0 x 22.5 48000 51.0 x 23.0 x 22.5 60000 51.0 x 23.0 x 22.5 60000 51.0 x 23.0 x 22.5 Shipping Weight (Ibs.) Supply Opening Return Opening Filter Sizes 73 73 73 73 94 94 94 94 18.25 x 15.0 18.25 x 15.0 18.25 x 15.0 18.25 x 15.0 21.75 x 15.5 21.75 x 15.5 21.75 x 15.5 21.75 x 15.5 15.75 x 18.75 15.75 x 18.75 15.75 x 18.75 15.75 x 18.75 19 x 19.5 19 x 19.5 19 x 19.5 19 x 19.5 Remote* Remote* Remote* Remote* Remote* Remote* Remote* Remote* Line Size GasLiquid /4 /4 3 /4 3 /4 7 /8 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 3 3 *Field Supplied For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-14 Effective 7/1/12 14-1011-28 Silver Series Air Handlers Table AH-15-A — Stud Mount Air Handler with Factory Installed Electric Heat Cooling Unit Capacity Model No. (Btuh) 4FWMA024A1005A 4FWMA024A1DS5A 4FWMA024A1008A 4FWMA024A1DS8A 4FWMA024A1010A 4FWMA024A1DS10A 4FWMA030A1008A 4FWMA030A1DS8A 4FWMA030A1010A 4FWMA030A1DS10A 4FWMA031A1008A 4FWMA031A1DS8A 4FWMA031A1010A 4FWMA031A1DS10A 4FWMA036A1010A 4FWMA036A1DS10A 4FWMA036A1015A 4FWMA042A1015A 4FWMA042A1020A 4FWMA048A1015A 4FWMA048A1020A 24000 24000 24000 24000 24000 24000 30000 30000 30000 30000 30000 30000 30000 30000 36000 36000 36000 42000 42000 48000 48000 Dimensions (in.) H x W x D Shipping Weight (Ibs.) Supply Opening Return Opening 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 57 57 57 57 57 57 57 57 57 57 65 65 65 65 65 65 65 65 65 65 65 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 FilterLine Size Sizes GasLiquid 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 /4 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 7 /8 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 3 3 Table AH-15-B — Stud Mount Air Handler with Factory Installed Electric Heat - R4.2 Models Cooling Unit Capacity Model No. (Btuh) 4FWMF024A1005A 4FWMF024A1DS5A 4FWMF024A1008A 4FWMF024A1DS8A 4FWMF024A1010A 4FWMF024A1DS10A 4FWMF030A1008A 4FWMF030A1DS8A 4FWMF030A1010A 4FWMF030A1DS10A 4FWMF031A1008A 4FWMF031A1DS8A 4FWMF031A1010A 4FWMF031A1DS10A 4FWMF036A1010A 4FWMF036A1DS10A 4FWMF036A1015A 4FWMF042A1015A 4FWMF042A1020A 4FWMF048A1015A 4FWMF048A1020A 24000 24000 24000 24000 24000 24000 30000 30000 30000 30000 30000 30000 30000 30000 36000 36000 36000 42000 42000 48000 48000 Dimensions (in.) H x W x D Shipping Weight (Ibs.) Supply Opening Return Opening 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 36.75 x 18.25 x 18 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 40 x 20.5 x 22 57 57 57 57 57 57 57 57 57 57 65 65 65 65 65 65 65 65 65 65 65 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 11 x 16.5 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 15 x 19 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 FilterLine Size Sizes GasLiquid 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 18 x 18 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 20 x 20 x 1 /43/8 /43/8 3 /43/8 3 /43/8 3 /43/8 3 /43/8 3 /43/8 3 /43/8 3 /43/8 3 /43/8 3 /43/8 3 /43/8 3 /43/8 3 /43/8 3 /43/8 3 /43/8 3 /43/8 7 /83/8 7 /83/8 7 /83/8 7 /83/8 3 3 Table AH-15-C — Optional Accessories Model Number Description 4FWMA/F BAYFPNLWAL01AA............ Wall Return Grill, Louvered................ 024-030 BAYFPNLWAL02AA............ Wall Return Grill, Louvered................ 031-036 BAYFPNLLOU01AA............ Unit Return Grill, Louvered................ 024-030 BAYFPNLLOU02AA............ Unit Return Grill, Louvered................ 031-036 BAYFPNLSOL01AA............ Lower Coil Panel, Solid...................... 024-030 BAYFPNLSOL02AA............ Lower Coil Panel, Solid...................... 031-036 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-15 Effective 7/1/12 14-1011-28 Silver Series Air Handlers Table AH-16-A — Furr-Down Air Handlers - Uncased with Factory Installed Electric Heat Cooling Unit Capacity Model No. (Btuh) 4FWDA022A1005A 4FWDA022A1008A 4FWDA022A1010A 4FWDA024A1005A 4FWDA024A1008A 4FWDA024A1010A 4FWDA030A1008A 4FWDA030A1010A 4FWDA036A1010A 24000 24000 24000 24000 24000 24000 30000 30000 36000 Dimensions (in.) H x W x D Shipping Weight (Ibs.) 0.25 x 37.25 x 22 1 10.25 x 37.25 x 22 10.25 x 37.25 x 22 10.25 x 43.25 x 22 10.25 x 43.25 x 22 10.25 x 43.25 x 22 10.25 x 43.25 x 22 10.25 x 43.25 x 22 10.25 x 43.25 x 22 60 60 60 64 64 64 64 64 74 Supply Opening Return Opening Filter Sizes 7 x 30 7 x 30 7 x 30 7 x 36 7 x 36 7 x 36 7 x 36 7 x 36 7 x 42 37.25 x 22 37.25 x 22 37.25 x 22 43.25 x 22 43.25 x 22 43.25 x 22 43.25 x 22 43.25 x 22 43.25 x 22 Remote* Remote* Remote* Remote* Remote* Remote* Remote* Remote* Remote* Line Size GasLiquid /4 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 3 3 Table AH-16-B — Furr-Down Air Handlers - Cased with Factory Installed Electric Heat Cooling Unit Capacity Model No. (Btuh) 4FWFA024A1005A 4FWFA024A1008A 4FWFA024A1010A 4FWFA030A1008A 4FWFA030A1010A 4FWFA031A1008A 4FWFA031A1010A 4FWFA036A1010A 24000 24000 24000 30000 30000 30000 30000 36000 Dimensions (in.) H x W x D Shipping Weight (Ibs.) Supply Opening Return Opening Filter Sizes 12 x 47 x 22.5 12 x 47 x 22.5 12 x 47 x 22.5 12 x 47 x 22.5 12 x 47 x 22.5 12 x 51 x 22.5 12 x 51 x 22.5 12 x 51 x 22.5 55 55 55 55 60 60 60 60 8 x 20.75 8 x 20.75 8 x 20.75 8 x 20.75 8 x 20.75 8 x 20.75 8 x 20.75 8 x 20.75 21 x 21.5 21 x 21.5 21 x 21.5 21 x 21.5 21 x 21.5 21 x 21.5 21 x 21.5 21 x 21.5 22 x 22 x 1 22 x 22 x 1 22 x 22 x 1 22 x 22 x 1 22 x 22 x 1 22 x 22 x 1 22 x 22 x 1 22 x 22 x 1 Line Size GasLiquid /4 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 3 3 *Field Supplied For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-16 Effective 7/1/12 14-1011-28 Heaters Silver Series Air Handlers Table AH-17-A — Heaters Silver Series Air Handlers BAYHTR -- HEATER DATA Heater Model NUMBER Capacity Capacity @ 240 Volt @ 208 Volt Voltage Control Stages Number of Heater Racks No. of Circuits Heater Amps per Circuit 208 Volt Heater Amps per Circuit 240 Volt Contains Circuit Breakers kW BTUH kW BTUH BAYHTR**1403SL0 3 10200 2.25 7700 208/240/1/60 1 1 1 10.8 12.5 No BAYHTR**1405SL0 4.8 16400 3.6 12300 208/240/1/60 1 1 1 17.3 20 No BAYHTR**1406SL0 6 20500 4.5 15400 208/240/1/60 1 1 1 21.6 25 No BAYHTR**1408SL0 8 27300 6 20500 208/240/1/60 1 2 1 28.8 33.3 No BAYHTR**1410SL0 9.6 32800 7.2 24600 208/240/1/60 1 2 1 34.6 40 No BAYHTRBK1415SL0 14.4 49100 10.8 36800 208/240/1/60 1 3 2 34.6/17.3 40/20 Yes BAYHTRBK1420SL0 19.2 65500 14.4 49100 208/240/1/60 1 4 2 34.6/34.6 40/40 Yes BAYHTRDS1405BL0 4.8 16400 3.6 12300 208/240/1/60 1 1 1 17.3 20 No BAYHTRDS1408BL0 8 27300 6 20500 208/240/1/60 1 2 1 28.8 33.3 No BAYHTR**1410BL0 9.6 32800 7.2 24600 208/240/1/60 1 2 1 34.6 40 No BAYHTRBK1415BL0 14.4 49100 10.8 36800 208/240/1/60 1 3 2 34.6/17.3 40/20 Yes BAYHTRBK1420BL0 19.2 65500 14.4 49100 208/240/1/60 1 4 2 34.6/34.6 40/40 Yes Note: Heaters with two circuits are displayed as Circuit 1/Circuit 2 (Minimum Circuit Ampacity for Circuit 1 includes Blower Motor Amp) ** = DS or Blank (DS = Pull Disconnect, Blank = terminal block) For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-17 Effective 7/1/12 14-1011-28 Heaters Silver Series Air Handlers Table AH-18-A — Heaters Silver Series Air Handlers MINIMUM HEATING AIRFLOW CFM - HEATER MATRIX 4FWCA, 4FWCF AIR HANDLER HEATER BAYHTR1405BL0 - 5 kw BAYHTR1408BL0 - 8 kw BAYHTR1410BL0 BAYHTRDS1410BL0 10 kw BAYHTRBK1415BL0 15 kw BAYHTRBK1420BL0 20 kw L/L L/L M/L H/M 4FWCA060A100A / 4FWCF060A100A 4FWCA061A100A / 4FWCF061A100A L/L L/L L/L L/L M/M BAYHTR1403SL0 BAYHTRDS1403SL0 3 kw BAYHTR1405SL0 BAYHTRDS1405SL0 5 kw BAYHTR1406SL0 BAYHTRDS1406SL0 6 kw BAYHTR1408SL0 BAYHTRDS1408SL0 8 kw BAYHTR1410SL0 BAYHTRDS1410SL0 10 kw 4FWCA024A100A / 4FWCF024A100A 4FWCA025A100A / 4FWCF025A100A L/L L/L L/L L/L M/L 4FWCA030A100A / 4FWCF030A100A 4FWCA031A100A / 4FWCF031A100A L/L L/L L/L L/L L/L L/L 4FWCA036A100A / 4FWCF036A100A L/L L/L L/L L/L L/L M/L BAYHTRBK1420SL0 20 kw L/L BAYHTRBK1415SL0 15 kw 4FWCA048A100A / 4FWCF048A100A 4FWCA049A100A / 4FWCF049A100A MODEL NUMBER M/L HEAT PUMP / COOLING MINIMUM HEATING AIRFLOW CFM - HEATER MATRIX 4FWHA, 4FWHF AIR HANDLER HEATER Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 2 / Tap 1 Tap 2 / Tap 1 4FWHA030A100A / 4FWHF030A100A 4FWHA036A100A / 4FWHF036A100A 4FWHA042A100A / 4FWHF042A100A 4FWHA048A100A / 4FWHF048A100A 4FWHA060A100A / 4FWHF060A100A 4FWHA061A100A / 4FWHF061A100A Tap 3 / Tap 2 Tap 3 / Tap 2 Tap 3 / Tap 3 BAYHTRBK1420BL0 20 kw Tap 3 / Tap 2 BAYHTRBK1415BL0 15 kw BAYHTR1410SL0 BAYHTRDS1410SL0 10 kw Tap 2 / Tap 1 BAYHTR1410BL0 BAYHTRDS1410BL0 10 kw BAYHTR1408SL0 BAYHTRDS1408SL0 8 kw Tap 1 / Tap 1 BAYHTR1408BL0 - 8 kw BAYHTR1406SL0 BAYHTRDS1406SL0 6 kw Tap 1 / Tap 1 BAYHTR1405BL0 - 5 kw BAYHTR1405SL0 BAYHTRDS1405SL0 5 kw Tap 1 / Tap 1 BAYHTRBK1420SL0 20 kw BAYHTR1403SL0 BAYHTRDS1403SL0 3 kw 4FWHA024A100A / 4FWHF024A100A 4FWHA025A100A / 4FWHF025A100A BAYHTRBK1415SL0 15 kw MODEL NUMBER Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 2 / Tap 1 Tap 1 / Tap 1 Tap 3 / Tap 2 Tap 2 / Tap 1 Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 1 / Tap 1 Tap 2 / Tap 1 Tap 3 / Tap 2 HEAT PUMP / COOLING For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-18 Effective 7/1/12 14-1011-28 Variable Speed Convertible Air Handlers 2½-5 Tons Table AH-19-A — Variable Speed R-410A Air-Tite™ with Comfort-R™ Enhanced Mode Option 200-230/1/6034 Unit Model No. 4TEE3F Cooling Capacity (Btuh) Dimensions (in.) Shipping H x W x D Weight (Ibs.) 4TEE3F31B1000B31,000 43x21.5x21 4TEE3F37B1000B 37,00045x23.5x21 4TEE3F40B1000B40,000 51.8x26x21 4TEE3F49C1000B 49,000 57.9x26x21 4TEE3F65B1000B565,000 62.8x26x21 4TEE3F66A1000B660,000 62.8x26x21 134 142 174 188 218 218 Supply Return Opening12Opening1 Filter Sizes 18.22x 11.02 19.5x18.07 20x20x1 20.22x11.02 21.5x18.0720x20x1 22.72x11.02 24x18.07 20x25x1 22.72x11.02 24x18.07 20x25x1 22.72x11.02 24x18.07 20x25x1 22.72x11.02 24x18.07 20x25x1 Line Size GasLiquid /4 /4 3 /4 3 /4 7 /8 7 /8 /16 /8 3 /8 3 /8 3 /8 3 /8 3 5 3 3 PhasING Out Table AH-19-B — Dual Circuit-Variable Speed R-410A Air-Tite™ with Comfort-R™ Enhanced Mode Option 200-230/1/6034 Unit Model No. Cooling Capacity (Btuh) Dimensions (in.) Shipping H x W x D Weight (Ibs.) 4TEE3F62B1000A5 65,000 62.75x26x21 218 PhasING Out PhasING Supply Return Opening12Opening1 Filter Sizes Line Size GasLiquid 3 3 22.72x11.02 24x18.22 20x25x1 /4 /Out 8 Out PhasING Out PhasING Table AH-19-C — Variable Speed - with Vortica™ R-410A Air-Tite™ with Comfort-R™ Enhanced Mode Option 200-230/1/6034 Unit Model No. Cooling Capacity (Btuh) Dimensions (in.) Shipping H x W x D Weight (Ibs.) Supply Return Opening12Opening1 Filter Sizes Line Size GasLiquid PhasING Out 4TEE3F39A1000A539,000 4TEE3F48B1000A548,000 4TEE3F64A1000A564,000 57.9x23.5x21 57.9x23.5x21 57.9x23.5x21 160 170 170 20.22x11.02 21.5x18.07 20.22x11.02 21.5x18.07 20.22x11.02 21.5x18.07 20x20x1 20x20x1 20x22x1 /4 /4 7 /8 /8 /8 3 /8 3 3 3 3 1Actual opening does not include flange. 2Adjustable duct flange allows for a flush fit with 11/2 inch insulation or 3/4 inch or 1 inch insulation. 3Variable fan speed. 4Metering Device = TXV-NB. 5Two piece cabinet. 6Mechanical connections on the TXV. See Heater Tables on Pages AH-22 and AH-23 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-19 Effective 7/1/12 14-1011-28 Variable Speed Convertible Air Handlers 2½-5 Tons 4TEE3F31-66 Table AH-20-A — Features 2½-5 1" thick foil face insulated cabinet.......................................................................................................................................................... 200/230 volt primary & 24 volt secondary transformer.......................................................................................................................... Access to heater circuit breakers / pull disconnects.............................................................................................................................. Built-in indoor fan delay function for increased efficiency...................................................................................................................... Check valve for heat pump application.................................................................................................................................................. Comfort-R™ enhanced dehumidification start-up................................................................................................................................ Compact 21" depth................................................................................................................................................................................ Corrosion resistant galvanized metal with attractive finish.................................................................................................................... Direct drive blower.................................................................................................................................................................................. Easy Air-Tite™ access to coil............................................................................................................................................................... Energy savings continuous fan.............................................................................................................................................................. Enhanced cooling/heating control.......................................................................................................................................................... Exclusive duct flange thermal break/seal.............................................................................................................................................. External brazed refrigerant connections................................................................................................................................................ Filter panel with door seal...................................................................................................................................................................... Internally checked Non-Bleed Thermal Expansion Valve...................................................................................................................... Internally enhanced finned coil tubing................................................................................................................................................... Low voltage terminal board.................................................................................................................................................................... Meets or exceeds Florida's 2% leakage criteria.................................................................................................................................... Polarized plugs for making motor and transformer electrical connections from air handler control box to electric heaters.................. Primary and secondary drain connections............................................................................................................................................ Ships vertical - converts to horizontal by laying on side........................................................................................................................ Six-way convertibility - upflow & horizontal, right, front & rear access; downflow and horizontal left with kit........................................ Soft start - ON cycle fan speed is increased gradually to reduce sound and drafts.............................................................................. Uses 1400 series heaters...................................................................................................................................................................... Variable speed ECM motor.................................................................................................................................................................... Versatile duct flange - allows flush fit 3/4", 1" or 1.5" duct insulation..................................................................................................... 10-year registered limited warranty on coil and all other functional parts (Residential Use)5................................................... Optional extended warranties available............................................................................................................................................ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ PhasING Out • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Table AH-20-B — Optional Accessories Model Number Description Shipping Weight PhasING Out AY28X079................Evaporator Defrost Control.................................. 1................................................................................................... ✔ AY28X084................Evaporator Defrost Control.................................. 1................................................................................................... ✔ BAY99X1232...........Knockout Cover Plate3............................................................................................................................................. ✔ BAYSPEK140B........Single Power Entry Kit.......................................... 5................................................................................................... ✔ TAYBASE100...........Downflow Subbase.............................................. 16..................................................................................................3 TAYBASE101...........Downflow Subbase.............................................. 16..................................................................................................2½ TAYBASE102...........Downflow Subbase.............................................. 16..................................................................................................3-5 TAYPLNM1001........Pedestal Plenum Upflow..................................... 10..................................................................................................2½-3 TAYPLNM101...........Pedestal Plenum Upflow..................................... 10..................................................................................................3-5 BAYPLNM120..........Pedestal Plenum Upflow........................................................................................................................................... ✔ TASB2154................21.5" Cabinet Mounting Stand..................................................................................................................................2½ TASB2354................23.5" Cabinet Mounting Stand..................................................................................................................................3 TASB2604................26" Cabinet Mounting Stand.....................................................................................................................................3-5 Comfort Controls — See Comfort Controls/Zone Sensors Section 14TEEF31B-center on plenum for 2" difference in width. 2Minimum order 1 unit ( 1 unit = 50 pieces). 3 Required if no electric heat is used. 4 For TASB ordering information see page AH-5. 5 Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-20 Effective 7/1/12 14-1011-28 Split System Air Handlers Single Phase 1½-5 Tons Table AH-21-A — R-410A Standard Efficiency Fully Convertible (200-230/1/60)7 Unit Model No. Cooling Capacity Dimensions (in.) Shipping (Btuh) H x W x D Weight (Ibs.) 4TEC3F18B1000A5 18,000 43x21.5x21 4TEC3F24B1000A5 24,000 43x21.5x21 4TEC3F30B1000A5 30,000 45x21.5x21 4TEC3F36B1000A5 36,000 45x21.5x21 4TEC3F42C1000A6 42,000 51.8x23.5x21 4TEC3F48B1000A4548,000 57.9x23.5x21 4TEC3F55B1000A558,000 57.9x26x21 4TEC3F60B1000A4660,000 57.9x23.5x21 114 121 121 135 165 188 193 193 Supply Return Opening12Opening1 18.22x11.02 18.22x11.02 18.22x11.02 18.22x11.02 20.22x11.02 20.22x11.02 22.72x11.02 20.22x11.02 Filter Sizes 19.5x18.0720x20x1 19.5x18.0720x20x1 19.5x18.0720x20x1 19.5x18.0720x20x1 21.5x18.07 20x20x1 21.5x18.07 20x20x1 24x18.07 20x25x1 21.5x18.07 20x22x1 Line Size GasLiquid /2 /8 3 /4 3 /4 3 /4 7 /8 7 /8 7 /8 1 /4 /16 5 /16 3 /8 3 /8 3 /8 3 /8 3 /8 1 PHasING out 4TEH3F 5 5 1Actual opening does not include flange. 2Adjustable duct flange allows for a flush fit with 11/2 inch insulation or 3/4 inch or 1 inch insulation. 3 Two piece cabinet. 4 Two piece cabinet with Vortica™. 53 fan speed. 64 fan speed. 7Metering Device = TXV-NB. Split System Air Handlers Single Phase 1½-5 Tons 4TEC3F Table AH-21-B — Features 1½-5 1" thick foil face insulated cabinet................................................................................................................................................................. — 200/230 volt primary & 24 volt secondary transformer................................................................................................................................. ✔ Air-Tite™ cabinet meets or exceeds Florida's 2% leakage criteria............................................................................................................. ✔ Approved for modular or manufactured homes............................................................................................................................................. ✔ Compact 21" depth for easy installation........................................................................................................................................................ ✔ Convertible upflow to horizontal left.............................................................................................................................................................. — Corrosion resistant galvanized metal with attractive finish........................................................................................................................... ✔ Direct drive motor.......................................................................................................................................................................................... — Easy access electrical controls and hook-up................................................................................................................................................ — Easy to clean coil and drain pan................................................................................................................................................................... — Easy to remove filters and blowers for ease of cleaning and replacement................................................................................................... — Electric heaters with breaker option on all sizes........................................................................................................................................... — Exclusive maximum width of 23.5"................................................................................................................................................................ — Electrical knock-outs on either side.............................................................................................................................................................. — Enhanced internally finned coil tubes........................................................................................................................................................... ✔ External access to heater circuit boards....................................................................................................................................................... ✔ Factory installed non-bleed TXV with mechanical fittings............................................................................................................................. ✔ Full line 1-1/2 - 5 tons.................................................................................................................................................................................... ✔ High efficiency direct drive multi-speed ECM motor..................................................................................................................................... ✔— Insulated cabinet........................................................................................................................................................................................... ✔ Low voltage wire nut connectors................................................................................................................................................................... ✔ Multi-speed blower motor; five ton model with direct drive ECM motor........................................................................................................ ✔ Non-bleed TXV with mechanical fittings........................................................................................................................................................ — Polarized plugs for making electrical connections from air handler control box to heaters.......................................................................... ✔ Ships vertical - converts to horizontal by laying on side............................................................................................................................... ✔ Sloped, free-draining composite material drain pan - no rust or leaks......................................................................................................... — Six-way convertibility: horizontal (left & right); front & rear access; upflow, downflow.................................................................................. ✔ Superior condensate performance............................................................................................................................................................... ✔ Uses standard size replaceable fiberglass filters.......................................................................................................................................... — Versatile duct flange - allows flush fit 3/4", 1" or 1.5" duct insulation............................................................................................................ ✔ 5-year limited warranty on coil and all other functional parts (Residential Use)................................................................................. ✔ Optional extended warranties available................................................................................................................................................... ✔ PHasING out • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • See Heater Tables on Pages AH-22 and AH-23 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-21 Effective 7/1/12 14-1011-28 Split System Air Handlers Single Phase 1½-5 Tons Table AH-22-A — Optional Accessories Model Number Description Shipping Weight 4TEC3F PHasING out AY28X079................Evaporator Defrost Control.............................. 1.............................................................................................................. ✔ AY28X084................Evaporator Defrost Control.............................. 1.............................................................................................................. ✔ BAY99X1232...........Knockout Cover Plate3.................................................................................................................................................... ✔ BAYSPEK140B........Single Power Entry Kit...................................... 5.............................................................................................................. ✔ TAYBASE100...........Downflow Subbase.......................................... 16............................................................................................................. 3½-5 TAYBASE101...........Downflow Subbase.......................................... 16............................................................................................................. 1½-3 TAYBASE102...........Downflow Subbase.......................................... 16............................................................................................................. 4½ TAYPLNM1001........Pedestal Plenum Upflow................................. 10............................................................................................................. ✔ TAYPLNM101...........Pedestal Plenum Upflow................................. 10............................................................................................................. 4½ BAYPLNM120..........Pedestal Plenum Upflow.................................................................................................................................................. 1½-5 TASB2153................21.5" Cabinet Mounting Stand......................................................................................................................................... 1½-3 TASB2353................23.5" Cabinet Mounting Stand......................................................................................................................................... 3½-5 TASB2603................26" Cabinet Mounting Stand............................................................................................................................................ 4½ Comfort Controls — See Comfort Controls/Zone Sensors Section 1 2/4TEH018,024,030-center on plenum for 2" difference in width. 2Minimum order 1 unit ( 1 unit = 50 pieces). 3 For TASB ordering information see page AH-5. Heaters for Split System and Convertible Air Handlers Table AH-22-A — Heaters - 4TEE, 4 TEC, 4TGB, 4TBE Heater CapacityCapacity Heater Amps Contains Model @ 240 Volts @ 208 Volts Rated Control per Circuit Circuit Number kWBTUH kWBTUH Voltage Stages 208 Volts 240Volt Breakers BAYHTR1405000 4.8016,400 3.612,300 BAYHTR1405BRKC 4.8016,400 3.612,300 BAYHTR1405PDC 4.8016,400 3.612,300 BAYHTR1408000 7.6826,200 5.7619,700 BAYHTR1408BRKC 7.6826,200 5.7619,700 BAYHTR1408PDC 7.6826,200 5.7619,700 BAYHTR1410000 9.6032,800 7.2024,600 BAYHTR1410BRKC 9.6032,800 7.2024,600 BAYHTR1410PDC 9.6032,800 7.2024,600 BAYHTR1415BRKC 15.3652,400 11.5339,300 BAYHTR1419BRKC 19.2065,500 14.4244,200 BAYHTR1425BRKC 24.9685,200 18.7363,900 Three Phase BAYHTR3410000 9.6032,800 7.20 24,600 BAYHTR3415000 15.3652,400 11.53 39,300 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 208/240/1/60 1 17.3 20 No 1 17.3 20 Yes 1 17.3 20 No 1 27.7 32 No 1 27.7 32 Yes 1 27.7 32 No 1 34.6 40 No 1 34.6 40 Yes 1 34.6 40 No 2 34.6/20.81240/241Yes 2 27.8/41.612 32/481Yes 3 38.1/34.6/17.3144/40/201Yes 208/240/3/60 208/240/3/60 1 1 30 33 34.6 38.2 No No 1Circuit 1/Circuit 2/Circuit 3* 2Heater can be converted to single circuit power entry by using BAYSPEK140B. This kit allows a single power circuit to be used with electric heaters that contain two (2) circuit breakers. BAYSPEK140B to be used with BAYHTR1415BRKB,C/ BAYHTR1419BRKB,C only. CAUTION:Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local electrical codes. *On model BAYHTR1425 only. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-22 Effective 7/1/12 14-1011-28 Heaters for Split System and Convertible Air Handlers MINIMUM HEATING AIRFLOW CFM COOLING/HEAT PUMP AIR FLOW - HEATER MATRIX AIR HEATER MODEL NUMBER BAYHTR— HANDLER 1405 000 1408 000 1410 000 BRKBRK BRK 1415 BRK 1419 BRK 1425 BRK MODEL PDC PDC PDC 15.36kW19.20kW24.96kW NUMBER 4.80kW 7.68kW 3410 000 3415 000 9.60kW NUMBER OF HEATER RACKS NUMBER OF 122245 111223 CIRCUITS 4TEE3F31 700/1000700/1000 700/1000700/11251000/1350 — 4TEE3F37 600/700 600/900 600/900 1000/13001000/1350 — 4TEE3F39 900/900900/900 900/900 900/PS PS/PS — 4TEE3F40 600/1100 600/1100 600/11001100/14001100/14001100/1400 4TEE3F48 800/800 800/800 800/800 PS/PSPS/PSPS/PS 4TEE3F49 700/1400 700/1400 700/14001400/16001400/16001400/1600 4TEE3F62 900/PS 900/PS 900/PS 1200/18001200/18001200/1800 4TEE3F64 900/900900/900 900/900 PS/PS 900/900900/1800 4TEE3F65 900/1500 900/1500 900/15001200/18001200/18001200/1800 4TEC3F18B L/LL/M L/M — — — 4TEC3F24B L/L L/L L/LL/M — — 4TEC3F30B L/L L/L L/LL/M — — 4TEC3F36B L/LL/L L/LL/H L/H — 4TEC3F42C ML/MLML/ML ML/MLML/PS ML/H — 4TEC3F48B L/LL/L L/LL/LPS/PS— 4TEC3F55B L/L L/L L/LL/PS L/H L/H 4TEC3F60B ML/MLML/ML ML/MLML/PS ML/MH — (Example: L=Low, M=Medium, H=High Speed) PS = Minimum speed tap varies based on air handler installation position. AS = Heater application is affected based on whether the outdoor unit is a heat pump or cooling unit. 000 =Pigtails, BRK = Contains circuit breakers, PDC = Contains Pull Disconnect * = Can be either C or D 1For Upflow position without heat pump, minimum setting is 1130. 2Minimum speed in downflow and horizontal right installations is 600 CFM. 3Minimum speed in upflow and horizontal right installations is 600 CFM. 4Minimum speed in downflow installations is 1400 CFM. 5Minimum speed in downflow installations is 1100 CFM. 6For horizontal right and downflow position, minimum speed for heat pump applications is 1100 CFM. 7Minimum speed for horizontal left installations is 1400 CFM; in horizontal right installations is 800 CFM. 8Minimum speed for horizontal right installations is 800 CFM. 9Minimum speed in downflow installations is 1400 CFM. 0Minimum speed in downflow and upflow installations is 1400 CFM. qMinimum speed in horizontal left and downflow installations is 1100 CFM. wMinimum speed in horizontal left installations is 1100 CFM. eMinimum speed in downflow installations is 1200 CFM. rMinimum speed in upflow installations is 900 CFM. tMinimum speed in upflow installations is 1500 CFM. yMinimum speed in horizontal left installations is 1800 CFM. uFor upflow applications only, minimum speed is 1500 for HP off and 1800 for HP on. iHeater not approved for horizontal right installation. oMinimum speed in horizontal left installations is 1500 CFM; in downflow installations is 1200 CFM. Minimum speed for upflow installations on 240 volts is 1800 CFM. Heater not approved for upflow installations on 208 volts. Minimum speed for horizontal right installations on 240 volts is 1200 CFM. Heater not approved for horizontal right installations on 208 volts. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-23 Effective 7/1/12 14-1011-28 Split System Air Handlers, R-410A Single Phase – 5-10 Tons Three Phase – 5-25 Tons • Ships in horizontal configuration, but quickly and easily converts to upflow • Expansion valve factory installed • Check valves for heat pump applications • Belt drive blower • Factory installed motor, belt, sheaves, contactor, low voltage terminal board • One inch filters on 5 to 10 ton units (rack convertible for field supplied two inch) • Captive screws remain on the panels for service ease • Low voltage terminal board • Drain Pan • Factory Installed (EDC) Evaporator Defrost Control • IAQ (Indoor Air Quality) sloped/free draining pan, no standing water • Two inch filters factory installed on 12½, 15, 20, 25 ton units • Supplemental heaters (electric, water, steam) fits directly on unit discharge for low installation cost • Single point power entry for reduced electrical power installation cost • Unit fully assembled to reduce field installation costs • Compact design with low service clearance to reduce building requirements • Brazed refrigerant piping connections • Fan relay UL listed and CSA Certified • Factory installed 2 speed variable frequency drive (VFD) option available for enhanced part load performance and minimum REQUIRED for CA Title 24 Compliance • Factory installed Single Zone VAV (SZVAV) option available for enhanced part load performance and space temperature control via varying airflow • Optional extended warranties 1 2 3 4 5 6 7 8 9 10 11 12 T W E 180 D 3 R 3 A A Capacity 061 = 5 Tons 180 = 15 Tons 090 = 7.5 Tons 240 = 20 Tons 120 = 10 Tons 300 = 25 Tons 150 = 12.5 Tons Factory-Installed Options 00 = Standard Motor - Electromechanical Controls 03 = 2 speed VFD Standard Motor - Electromechanical Controls 04 = 2 speed VFD Oversized Motor - Electromechanical Controls R3 = SZVAV VFD Standard Motor - ReliaTel™ Controls R4 = SZVAV VFD Oversized Motor - ReliaTel™ Controls 5, 71/2, 10, 121/2, 15, 20, 25 Ton TWE Convertible Air Handlers (Upflow or Horizontal Only) Table AH-24-A — Single Circuit Coil - R-410A5 Unit Power Supply Capacity Drive Dimensions (in.)4 Tons Model No. Volts/Phase/Hz (Btuh) FCCV Type H x W x D Single Phase 5 TWE061D100AA 71/2TWE090D100AA1 10 TWE120D100AA1 Three Phase 5 TWE061D300AA 5 TWE061D400AA 5 TWE061DW00AA Shipping Max Fuse Size Weight or Max Circuit (Ibs.) MCA* Breaker3* 208-230/1/60 208-230/1/60 208-230/1/60 60,000 90,000 120,000 TXV TXV TXV Belt Belt Belt 48 x 39 x 23 54 x 49 x 26 54 x 65 x 26 263 360 429 7.5 8.5 10.6 15 15 15 208-230/3/60 460/3/60 575/3/60 60,000 60,000 60,000 TXV TXV TXV Belt Belt Belt 48 x 39 x 23 48 x 39 x 23 48 x 39 x 23 263 263 263 3.1 1.6 1.6 15 15 15 71/2TWE090D300AA12 208-230/3/60 71/2TWE090DW00AA1 575/3/60 90,000 90,000 TXV TXV Belt Belt 54 x 49 x 26 54 x 49 x 26 360 360 6.6 2.3 15 15 10TWE120D300AA12 208-230/3/60 10TWE120DW00AA1 575/3/60 120,000 120,000 TXV TXV Belt Belt 54 x 65 x 26 54 x 65 x 26 429 429 7.8 2.9 15 15 1Control transformer not included. Order control transformer accessory when matching these air handlers with 3-5 ton condensing units. 2Ships wired for 208-230/3/60. Field convertible to 460/3/60. 3HACR type circuit breaker per NEC. 4Dimensions based on Upflow position. 5All air handlers are shipped with the drain pan installed in the horizontal position. For vertical configuration, the drain pan should be repositioned before setting the air handler. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-24 Effective 7/1/12 14-1011-28 Split System Air Handlers, R-410A Single Phase – 5-10 Tons Three Phase – 5-25 Tons • Ships in horizontal configuration, but quickly and easily converts to upflow • Expansion valve factory installed • Check valves for heat pump applications • Belt drive blower • Factory installed motor, belt, sheaves, contactor, low voltage terminal board • One inch filters on 5 to 10 ton units (rack convertible for field supplied two inch) • Captive screws remain on the panels for service ease • Low voltage terminal board • Drain Pan • Factory Installed (EDC) Evaporator Defrost Control • IAQ (Indoor Air Quality) sloped/free draining pan, no standing water • Two inch filters factory installed on 12½, 15, 20, 25 ton units • Supplemental heaters (electric, water, steam) fits directly on unit discharge for low installation cost • Single point power entry for reduced electrical power installation cost • Unit fully assembled to reduce field installation costs • Compact design with low service clearance to reduce building requirements • Brazed refrigerant piping connections • Fan relay UL listed and CSA Certified • Factory installed 2 speed variable frequency drive (VFD) option available for enhanced part load performance and minimum REQUIRED for CA Title 24 Compliance • Factory installed Single Zone VAV (SZVAV) option available for enhanced part load performance and space temperature control via varying airflow • Optional extended warranties 1 2 3 4 5 6 7 8 9 10 11 12 T W E 180 D 3 R 3 A A Capacity 061 = 5 Tons 180 = 15 Tons 090 = 7.5 Tons 240 = 20 Tons 120 = 10 Tons 300 = 25 Tons 150 = 12.5 Tons Factory-Installed Options 00 = Standard Motor - Electromechanical Controls 03 = 2 speed VFD Standard Motor - Electromechanical Controls 04 = 2 speed VFD Oversized Motor - Electromechanical Controls R3 = SZVAV VFD Standard Motor - ReliaTel™ Controls R4 = SZVAV VFD Oversized Motor - ReliaTel™ Controls 5, 71/2, 10, 121/2, 15, 20, 25 Ton TWE Convertible Air Handlers (Upflow or Horizontal Only) Table AH-25-A — Dual Circuit Coil — R-410A Unit Power Supply Capacity Drive Dimensions (in.)4 Tons Model No. Volts/Phase/Hz (Btuh) FCCV Type H x W x D Single Phase 5 TWE061E100AA 71/2 TWE090E100AA1 10 TWE120E100AA1 Three Phase 5 TWE061E300AA 5 TWE061E400AA Shipping Max Fuse Size Weight or Max Circuit (Ibs.) MCA* Breaker3* 208-230/1/60 208-230/1/60 208-230/1/60 60,000 90,000 120,000 TXV TXV TXV Belt Belt Belt 48 x 39 x 23 54 x 49 x 26 54 x 65 x 26 263 360 429 7.5 8.5 10.6 15 15 15 208-230/3/60 460/3/60 60,000 60,000 TXV TXV Belt Belt 48 x 39 x 23 48 x 39 x 23 263 263 3.1 1.6 15 15 71/2TWE090E300AA12 208-230/3/60 90,000 TXV Belt 54 x 49 x 26 360 6.6 15 10TWE120E300AA12 208-230/3/60 10TWE120EW00AA1 575/3/60 120,000 120,000 TXV TXV Belt Belt 54 x 65 x 26 54 x 65 x 26 429 429 7.8 2.9 15 15 12 ½ 12 ½ 12 ½ TWE150E300AA TWE150E400AA2 TWE150EW00AA 208-230/3/60 460/3/60 575/3/60 150,000 150,000 150,000 TXV TXV TXV Belt Belt Belt 69 x 81 x 30 69 x 81 x 30 69 x 81 x 30 730 730 730 7.4 3.4 2.8 15 15 15 15 TWE180E300AA 15TWE180E400AA2 15 TWE180EW00AA 208-230/3/60 460/3/60 575/3/60 180,000 180,000 180,000 TXV TXV TXV Belt Belt Belt 69 x 81 x 30 69 x 81 x 30 69 x 81 x 30 729 729 729 11.8 5.8 4.3 20 15 15 20 20 20 TWE240E300BA TWE240E400BA TWE240EW00BA 208-230/3/60 460/3/60 575/3/60 246,000 246,000 246,000 TXV TXV TXV Belt Belt Belt 72 x 94 x 32 72 x 94 x 32 72 x 94 x 32 891 891 891 18.1 8.4 6.5 25 15 15 25 25 25 TWE300E300A TWE300E400A TWE300EW00A 208-230/3/60 460/3/60 575/3/60 292,000 292,000 292,000 TXV TXV TXV Belt Belt Belt 72 x 94 x 32 72 x 94 x 32 72 x 94 x 32 972 972 972 24.5 11.2 8.9 30 20 15 1Control transformer not included. Order control transformer accessory when matching these air handlers with 3-5 ton condensing units. 2Ships wired for 208-230/3/60. Field convertible to 460/3/60. 3HACR type circuit breaker per NEC. 4Dimensions based on Upflow position. 5All air handlers are shipped with the drain pan installed in the horizontal position. For vertical configuration, the drain pan should be repositioned before setting the air handler. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-25 Effective 7/1/12 14-1011-28 Split System Air Handlers, R-410A Single Phase – 5-10 Tons Three Phase – 5-25 Tons Table AH-26-A — 6 - 10 Ton Electric Heater Selection Model Number Description Used With BAYHTRL106A BAYHTRL112A BAYHTRL117A BAYHTRL123A BAYHTRL129A BAYHTRL305A BAYHTRL310A BAYHTRL315A BAYHTRL325A BAYHTRL335A BAYHTRL405A BAYHTRL410A BAYHTRL415A BAYHTRL425A BAYHTRL435A BAYHTRLW05A BAYHTRLW10A BAYHTRLW15A BAYHTRLW25A BAYHTRLW35A 4.33/5.76 kW Heater 208/240/1 Phase 8.65/11.52 kW Heater 208/240/1 Phase 12.98/17.28 kW Heater 208/240/1 Phase 17.30/23.04 kW Heater 208/240/1 Phase 21.65/28.80 kW Heater 208/240/1 Phase 3.75/5.00 kW Heater 208/240/3 Phase 7.45/9.96 kW Heater 208/240/3 Phase 11.25/14.96 kW Heater 208/240/3 Phase 18.71/24.92 kW Heater 208/240/3 Phase 26.20/34.88 kW Heater 208/240/3 Phase 5.00 kW Heater 460/3 Phase 9.96 kW Heater 460/3 Phase 14.96 kW Heater 460/3 Phase 24.92 kW Heater 460/3 Phase 34.88 kW Heater 460/3 Phase 5 kW Heater 575/3 Phase 9.96 kW Heater 575/3 Phase 14.96 kW Heater 575/3 Phase 24.92 kW Heater 575/3 Phase 34.88 kW Heater 575/3 Phase TWE061D1-TWE120E1 TWE061D1-TWE120E1 TWE061D1-TWE120E1 TWE061D1-TWE120E1 TWE061D1-TWE120E1 TWE061D3-TWE120E3 TWE061D3-TWE120E3 TWE061D3-TWE120E3 TWE061D3-TWE120E3 TWE061D3-TWE120E3 TWE061D4-TWE120E31 TWE061D4-TWE120E31 TWE061D4-TWE120E31 TWE061D4-TWE120E31 TWE061D4-TWE120E31 TWE061DW-TWE120EW TWE061DW-TWE120EW TWE061DW-TWE120EW TWE061DW-TWE120EW TWE061DW-TWE120EW Table AH-26-B — 12½ - 20 Ton Electric Heater Selection Model Number Description Used With BAYHTRM310A BAYHTRM320A BAYHTRM330A BAYHTRM350A BAYHTRM410A BAYHTRM420A BAYHTRM430A BAYHTRM450A BAYHTRMW10A BAYHTRMW20A BAYHTRMW30A BAYHTRMW50A 7.50/10.0 kW Heater 208/230 3 Phase 14.96/19.92 kW Heater 208/230 3 Phase 22.50/29.92 kW Heater 208/230 3 Phase 37.42/49.84 kW Heater 208/230 3 Phase 10.0 kW Heater 460/3 Phase 19.92 kW Heater 460/3 Phase 29.92 kW Heater 460/3 Phase 49.84 kW Heater 460/3 Phase 10.0 kW Heater 575/3 Phase 19.92 kW Heater 575/3 Phase 29.92 kW Heater 575/3 Phase 49.84 kW Heater 575/3 Phase TWE150E3-TWE300E3 TWE150E3-TWE300E3 TWE150E3-TWE300E3 TWE150E3-TWE300E3 TWE150E31-TWE300E4 TWE150E31-TWE300E4 TWE150E31-TWE300E4 TWE150EW-TWE300EW TWE150EW-TWE300EW TWE150EW-TWE300EW TWE150EW-TWE300EW TWE150EW-TWE300EW 1 Field convertible to 460/3/60. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-26 Effective 7/1/12 14-1011-28 Split System Air Handlers, R-410A Single Phase – 5-10 Tons Three Phase – 5-25 Tons Table AH-27-A — 5 – 20 Ton Accessory Selection Model Number Description Used With Subbase BAYBASE009A Vertical Air Handler Subbase TWE061D, TWE061E BAYBASE010A Vertical Air Handler Subbase TWE090D, TWE090E BAYBASE011A Vertical Air Handler Subbase TWE120D, TWE120E BAYBASE012A Vertical Air Handler Subbase TWE150E, TWE180E BAYBASE013A Vertical Air Handler Subbase TWE240E, TWE300E Grille BAYGRLE001A Return Air Grille TWE061D/E BAYGRLE002A Return Air Grille TWE090D/E BAYGRLE003A Return Air Grille TWE120D/E BAYGRLE004A Return Air Grille TWE150E, TWE180E BAYGRLE005A Return Air Grille TWE240E, TWE300E High Static Motor BAYHSMT104A 1.5HP (230/1) w/ 1VL44 motor sheave w/ AK54 fan sheave w/ A44 belt TWE061D1/E1 BAYHSMT105A 1.5HP (230-460/3) w/ 1VL44 motor sheave w/ AK54 fan sheave w/ A44 belt TWE061D3-4/E3-4 BAYHSMT106A 1.5HP (575/3) w/ 1VL44 motor sheave w/ AK54 fan sheave w/ A44 belt TWE061DW/EW BAYHSMT107A 2 HP (230/1) w/ 1VL44 motor sheave w/ AK66 fan sheave w/ A50 belt TWE090D1/E1 BAYHSMT108A 2 HP (230/460/3) w/ 1VL44 motor sheave w/ AK66 fan sheave w/ A50 belt TWE090D3/E3 BAYHSMT109A 2 HP (575/3) w/ 1VL44 motor sheave w/ AK66 fan sheave w/ A50 belt TWE090DW/EW BAYHSMT110A 3 HP (230/460/3) w/ 1VP44 motor sheave w/ AK54 fan sheave w/ AX48 belt TWE090D3/E3 BAYHSMT111A 3 HP (575/3) w/ 1VP44 motor sheave w/ AK54 fan sheave w/ AX48 belt TWE090DW/EW BAYHSMT112A 3 HP (230/460/3) w/ 1VP44L motor sheave w/ AK74 fan sheave w/ A51 belt TWE120D3/E3 BAYHSMT113A 3 HP (575/3) w/ 1VP44L motor sheave w/ AK74 fan sheave w/ A51 belt TWE120DW/EW BAYHSMT114A 3 HP (230/460/3) w/ 1VP44L motor sheave w/ BK72 fan sheave w/ A51 belt TWE150E3 BAYHSMT115A 3 HP (575/3) w/ 1VP44L motor sheave w/ BK72 fan sheave w/ A51 belt TWE150EW BAYHSMT116A 5 HP (230/3) w/ 1VP50L motor sheave w/ BK72 fan sheave w/ BX55 belt TWE150E3 BAYHSMT117A 5 HP (460/3) w/ 1VP50L motor sheave w/ BK72 fan sheave w/ BX55 belt TWE150E4 BAYHSMT118A 5 HP (575/3) w/ 1VP50L motor sheave w/ BK72 fan sheave w/ BX55 belt TWE150EW BAYHSMT119A 5 HP (230/3) w/ 1VP50L motor sheave w/ BK85 fan sheave w/ BX58 belt TWE180E3 BAYHSMT120A 5 HP (460/3) w/ 1VP50L motor sheave w/ BK85 fan sheave w/ BX58 belt TWE180E4 BAYHSMT121A 5 HP (575/3) w/ 1VP50L motor sheave w/ BK85 fan sheave w/ BX58 belt TWE180EW BAYHSMT122A 7.5 HP (230/460/3) w/ 1VP60 motor sheave w/ BK90 fan sheave w/ BX60 belt TWE240E3/4 BAYHSMT123A 7.5 HP (575/3) w/ 1VP60 motor sheave w/ BK90 fan sheave w/ BX60 belt TWE240EW Isolators BAYISLT004A1234 Rubber Isolator Floor (blue) TWE061D-TWE120E BAYISLT009A123 Rubber Isolator Floor (red) TWE150E, TWE180E BAYISLT010A123 Rubber Isolator Floor (green) TWE240E, TWE300E BAYISLT012B3 Rubber Isolator Suspended (red/green) TWE150E, TWE180E BAYISLT013B34 Rubber Suspended (red/green) TWE061D/E BAYISLT014A34 Rubber Suspended (green) TWE090D/E BAYISLT015B34 Rubber Suspended (green/black) TWE120D/E BAYISLT016B3 Rubber Suspended (red/green) TWE240E, TWE300E BAYISLT019A123 Steel Spring Isolator Floor (red) TWE061D/E, TWE090D/E, TWE120D/E BAYISLT021A123 Steel Spring Isolator Floor (black) TWE150E, TWE180E BAYISLT032A123 Steel Spring Isolator Floor (black/yellow) TWE240E BAYISLT028A3 Steel Spring Isolator Suspended (tan) TWE061D/E BAYISLT029A3 Steel Spring Isolator Suspended (red) TWE090D/E, TWE120D/E BAYISLT030A3 Steel Spring Isolator Suspended (black) TWE150E, TWE180E BAYISLT031B3 Steel Spring Isolator Suspended (black/yellow) TWE240E, TWE300E Low Static Drive Kit BAYLSMT001A Low Static Drive Kit TWE240E 1When the Air handler is in the vertical position and close proximity trapping of condensate is required, use of subbase is required. 2Requires use of subbase accessory. 3Units having steam of hot water coils applied vertically or horizontally check IOM for proper Isolator kit selection. 4Do not use if blower will operate less than 600 RPM. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-27 Effective 7/1/12 14-1011-28 Split System Air Handlers, R-410A Single Phase – 5-10 Tons Three Phase – 5-25 Tons Table AH-28-A — 5 – 20 Ton Accessory Selection Model Number Description Used With Plenum BAYPLNM015B2 Discharge Plenum & Grille BAYPLNM016B2 Discharge Plenum & Grille BAYPLNM017B2 Discharge Plenum & Grille BAYPLNM018B2 Discharge Plenum/Hydronic Coil Plenum & Grille BAYPLNM019B2 Discharge Plenum/Hydronic Coil Plenum & Grille BAYPLNM020B2 Hydronic Coil Discharge Plenum & Grille BAYPLNM021B2 Hydronic Coil Discharge Plenum & Grille BAYPLNM022B2 Hydronic Coil Discharge Plenum & Grille BAYPLNM030A2 Electric Heat Discharge Plenum & Grille BAYPLNM031A2 Electric Heat Discharge Plenum & Grille BAYPLNM032A2 Electric Heat Discharge Plenum & Grille BAYPLNM033A2 Electric Heat Discharge Plenum & Grille BAYPLNM034A2 Electric Heat Discharge Plenum & Grille Transformer BAYTFMR011A1 75va transformer (230V) BAYTFMR012A1 75va transformer BAYTFMR013A1 Water Kits BAYWATR022A2 Steam Coil Enclosure BAYWATR023A2 BAYWATR024A2 BAYWATR025A2 BAYWATR026A2 BAYWATR027A2 Hot Water Coil Enclosure BAYWATR028A2 BAYWATR029A2 BAYWATR030A2 BAYWATR031A2 Wire Kit BAYWRKT002A3 180 Blower Discharge Reversal Kit TWE061D/E TWE090D/E TWE120D/E TWE150E, TWE180E TWE240E, TWE300E TWE061D/E TWE090D/E TWE120D/E TWE061D/E TWE090D/E TWE120D/E TWE150E, TWE180E TWE240E, TWE300E TWE090D3, TWE090E3, TWE120D3, TWE120E3 TWE090D4/W, TWE090E4/W, TWE120D4/W, TWE120E4/W TWE090DK, TWE090EK, TWE120DK, TWE120EK TWE061D/E TWE090D/E TWE120D/E TWE150E, TWE180E TWE240E, TWE300E TWE061D/E TWE090D/E TWE120D/E TWE150E, TWE180E TWE240E, TWE300E TWE061D-TWE120E 1Required when 6 -10 Ton Air Handlers are matched with 3-5 Ton condensing units. 2When installed horizontally, plenum/water coil must be self supported. 3Cannot be used on TWE150-240, due to motor mount location. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-28 Effective 7/1/12 14-1011-28 Split System Air Handlers 5-25 Tons Factory Supplied Factory Supplied Accessories Accessories 20 Tons) Tons) A A Air Air Handler Handler (TWE (TWE 55 –– 20 Unit Outdoor Condensing Unit B B Outdoor (TTA (TTA -–Cooling Cooling 66 –– 20 25 Tons) (TWA (TWA -–Heat Heat Pump Pump 66 –– 20 20 Tons) Tons) P Discharge Plenum and Grille Discharge Plenum and Grille P (BAYPLNM) (BAYPLNM) EH Electric Heater and Casing (BAYHTRL) Electric Heater and(13 Casing (BAYHTRL) on Top of Unit H x 30 W x 17 D) EH Fits Fits on Top of Unit (13 H x 30 W x 17 D) (BAYBASE) SB Subbase EH P I SB Subbase (BAYBASE) Isolators (BAYISLT) I Isolators (BAYISLT) RG Return Grille (BAYGRLE) RG Return Grille (BAYGRLE) CG Coil Guards (BAYGARD) LA Low Ambient Control (BAYLOAM) CG Coil Guards (BAYLOAM) WC Steam/Hot Water Coil (BAYWATR) WC Steam/Hot Water Coil (BAYWATR) WC A To Convert from Vertical to Horizontal Simply Lay Down Drain Connections at Top and Bottom of Coil SB I I RG CG Drain Connections at Top and Bottom of Coil B For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AH-29 Effective 7/1/12 14-1011-28 Split System – Cased Heat Pump and Cooling Coils Table COIL-1-A — Aluminum High Efficiency Staged System Cased Coil Convertible (Upflow/ Downflow/ Horizontal Left or Right) R-410A Refrigerant Model Number Comfort TM coil 4TXC-CC Comfort™ Coil Nom. Cap. Cooling Coil Refrigerant (Btuh) Type Control 4TXCB003CC3HCB24,000 4TXCB004CC3HCB36,000 4TXCC005CC3HCB36,000 4TXCC006CC3HCB24,000 4TXCC007CC3HCB36,000 4TXCC008CC3HCB60,000 4TXCD009CC3HCB60,000 4TXCD010CC3HCB60,000 A A A A A A A A Outlet Dim. (in.) W/H x D TXVNB1155/8 x 193/8 TXVNB1155/8 x 193/8 TXVNB1191/8 x 193/8 TXVNB1191/8 x 193/8 TXVNB1191/8 x 193/8 TXVNB1191/8 x 193/8 TXVNB1225/8 x 193/8 TXVNB1225/8 x 193/8 Overall Dim. (in.) H x W x D 22.6 x 17.5 x 21.5 26.9 x 17.5 x 21.5 26.9 x 21 x 21.5 22.6 x 21 x 21.5 26.9 x 21 x 21.5 30.1 x 21 x 21.5 30.1 x 24.6 x 21.5 30.1 x 24.6 x 21.5 ShippingLine Size Weight OD OD (Ibs.) Gas Liq. 45 49 51 48 51 65 68 68 /8 /4 3 /4 5 /8 3 /4 3 /4 3 /4 3 /4 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 5 3 3 3 Table COIL-1-B — Aluminum Cased Coil Convertible (Upflow/ Downflow/ Horizontal Left or Right) R-410A Refrigerant Model Number Comfort TM coil 4TXC-BC Comfort™ Coil Nom. Cap. Cooling Coil Refrigerant (Btuh) Type Control 4TXCA018BC3HCB18,000 4TXCA024BC3HCB24,000 4TXCB025BC3HCB24,000 4TXCB031BC3HCB30,000 4TXCB032BC3HCB36,000 4TXCB036BC3HCB36,000 4TXCC037BC3HCB37,000 4TXCB042BC3HCB42,000 4TXCC043BC3HCB43,000 4TXCC044BC3HCB48,000 4TXCB048BC3HCB48,000 4TXCC049BC3HCB48,000 4TXCD050BC3HCB48,000 4TXCC060BC3HCB60,000 4TXCD061BC3HCB60,000 4TXCD063BC3HCB60,000 4TXCD064BC3HCB60,000 A A A A A A A A A A A A A A A A A TXVNB1125/8 x 193/8 TXVNB1125/8 x 193/8 TXVNB1155/8 x 193/8 TXVNB1155/8 x 193/8 TXVNB1155/8 x 193/8 TXVNB1155/8 x 193/8 TXVNB1191/8 x 193/8 TXVNB1155/8 x 193/8 TXVNB1191/8 x 193/8 TXVNB1191/8 x 193/8 TXVNB1155/8 x 193/8 TXVNB1191/8 x 193/8 TXVNB1225/8 x 193/8 TXVNB1191/8 x 193/8 TXVNB1225/8 x 193/8 TXVNB1225/8 x 193/8 TXVNB1225/8 x 193/8 1 Start Kit may be required on outdoor unit. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. Outlet Dim. (in.) W/H x D COIL-1 Overall Dim. (in.) H x W x D 22.6 x 14.5 x 21.5 22.6 x 14.5 x 21.5 17.6 x 17.5 x 21.5 17.6 x 17.5 x 21.5 22.6 x 17.5 x 21.5 22.6 x 17.5 x 21.5 22.6 x 21 x 21.5 22.6 x 17.5 x 21.5 22.6 x 21 x 21.5 26.9 x 21 x 21.5 26.9 x 17.5 x 21.5 26.9 x 21 x 21.5 26.9 x 24.6 x 21.5 30.1 x 21 x 21.5 30.1 x 24.6 x 21.5 30.1 x 24.6 x 21.5 30.1 x 24.6 x 21.5 ShippingLine Size Weight OD OD (Ibs.) Gas Liq. 34 34 38 38 45 45 48 45 48 49 49 51 55 65 68 68 68 /8 5/16 /8 5/16 5 /85/16 5 /85/16 3 /4 3/8 3 /4 3/8 3 /4 3/8 3 /4 3/8 3 /4 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 5 5 Effective 7/1/12 14-1011-28 Split System – Uncased Heat Pump and Cooling Coils Table COIL-2-A — Aluminum Uncased Coil (Upflow/Downflow) R-410A Refrigerant 4TXA-BC Comfort™ Coil Model Number Nom. Cap. Cooling Coil Refrigerant (Btuh) Type Control 4TXAA018BC3HUB 4TXAA024BC3HUB 4TXAB025BC3HUB 4TXAB031BC3HUB 4TXAB032BC3HUB 4TXAB036BC3HUB 4TXAC037BC3HUB 4TXAB042BC3HUB 4TXAC043BC3HUB 4TXAC044BC3HUB 4TXAB048BC3HUB 4TXAC049BC3HUB 4TXAD050BC3HUB 4TXAC060BC3HUB 4TXAD061BC3HUB 4TXAD064BC3HUB 18,000 24,000 24,000 30,000 36,000 36,000 36,000 42,000 42,000 48,000 48,000 48,000 48,000 60,000 60,000 60,000 A A A A A A A A A A A A A A A A TXVNB1 TXVNB1 TXVNB1 TXVNB1 TXVNB1 TXVNB1 TXVNB1 TXVNB1 TXVNB1 TXVNB1 TXVNB1 TXVNB1 TXVNB1 TXVNB1 TXVNB1 TXVNB1 1 Start Kit may be required on outdoor unit. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. COIL-2 Overall Dim. (in.) H x W x D 17.4 x 13.3 x 21.1 17.4 x 13.3 x 21.1 15.9 x 16.3 x 21.1 15.9 x 16.3 x 21.1 21.2 x 16.3 x 21.1 21.2 x 16.3 x 21.1 20.8 x 19.8 x 21.1 21.2 x 16.3 x 21.1 20.8 x 19.8 x 21.1 25.3 x 19.8 x 21.1 25.3 x 16.3 x 21.1 24.9 x 19.8 x 21.1 24.4 x 23.3 x 21.1 29.1 x 19.8 x 21.1 28.6 x 23.3 x 21.1 28.6 x 23.3 x 21.1 ShippingLine Size Weight OD OD (Ibs.) Gas Liq. 21 21 24 24 32 32 33 32 33 38 36 38 39 44 45 45 /8 /8 5 /8 5 /8 3 /4 3 /4 3 /4 3 /4 3 /4 7 /8 7 /8 7 /8 7 /8 7 /8 7 /8 7 /8 5 5 /16 /16 5 /16 5 /16 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 5 5 Effective 7/1/12 14-1011-28 Split System – Cased Heat Pump and Cooling Coils Table COIL-3-A — Aluminum Cooling ONLY Cased Coils- Upflow R-410A Model Number ComfortTM coil 4CXC-CC Comfort™ Coil Nom. Cap. Cooling Coil Refrigerant (Btuh) Type Control Outlet Dim. (in.) H x D Overall Dim. (in.) H x W x D ShippingLine Size Weight OD OD (Ibs.) Gas Liq. 4CXCA024CC3CUB24,000 A TXVNB1125/8 x 193/822.6x14.5x21.5 4CXCB025CC3CUB24,000 A TXVNB1155/8 x 193/817.6x17.5x21.5 4CXCB031CC3CUB30,000 A TXVNB1155/8 x 193/817.6x17.5x21.5 4CXCB036CC3CUB36,000 A TXVNB1155/8 x 193/822.6x17.5x21.5 4CXCC037CC3CUB37,000 A TXVNB1191/8 x 193/822.6x21x21.5 4CXCB042CC3CUB42,000 A TXVNB1155/8 x 193/822.6x17.5x21.5 4CXCC043CC3CUB43,000 A TXVNB1191/8 x 193/822.6x21x21.5 4CXCC049CC3CUB48,000 A TXVNB1191/8 x 193/826.9x21x21.5 4CXCD061CC3CUB60,000 A TXVNB1225/8 x 193/830.1x24.5x21.5 33 43 43 45 48 45 48 52 67 /8 3/8 /4 3/8 3 /4 3/8 3 /4 3/8 3 /4 3/8 3 /4 3/8 3 /4 3/8 7 /8 3/8 7 /8 3/8 5 3 Table COIL-3-B — Aluminum Cased Horizontal Flat Coils R-410A Refrigerant Model Number Nom. Cap. Cooling Coil Refrigerant (Btuh) Type Control 4TXFH024CZ3HHB 4TXFH033CC3HHB 4TXFH036CZ3HHB 4TXFH041CC3HHB 4TXFH054CC3HHB 4TXFH063CZ3HHB 24,000Flat TXVNB1 34,000Flat TXVNB1 36,000Flat TXVNB1 44,000Flat TXVNB1 58,000Flat TXVNB1 61,000Flat TXVNB1 Outlet Dim. (in.) H x D Overall Dim. (in.) H x W x D 21 x 331/4 21 x 24 21 x 331/4 21 x 331/4 21 x 331/4 27 x 331/4 22.7 x 10.2 x 37.5 22.7 x 10.2 x 28.2 22.7 x 10.2 x 37.5 22.7 x 10.2 x 37.5 22.7 x 10.2 x 37.5 28.7 x 10.2 x 37.5 ShippingLine Size Weight OD OD (Ibs.) Gas Liq. 48 49 53 57 55 63 Important: This table applies to all outdoor units except the 4TTZ0 or 4TWZ0. /8 /4 3 /4 3 /4 7 /8 7 /8 /8 /16 3 /8 3 /8 3 /8 3 /8 5 3 3 5 Table COIL-3-C — Aluminum Cased Horizontal Flat Coils R-410A Refrigerant Model Number 4TXF Nom. Cap. Cooling Coil Refrigerant (Btuh) Type Control 4TXFH024CZ3HHB 24,000Flat TXVNB1 4TXFH036CZ3HHB 36,000Flat TXVNB1 4TXFH063CZ3HHB 61,000Flat TXVNB1 Outlet Dim. (in.) H x D Overall Dim. (in.) H x W x D 21 x 331/4 22.7 x 10.2 x 37.5 21 x 331/4 22.7 x 10.2 x 37.5 27 x 331/4 28.7 x 10.2 x 37.5 ShippingLine Size Weight OD OD (Ibs.) Gas Liq. 48 53 63 /8 /4 7 /8 /8 /8 3 /8 5 3 3 3 Important: Only these Flat Coils May be used with the 4TTZ0 or 4TWZ0 outdoor units. 1Start Kit may be required on outdoor unit. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. COIL-3 Effective 7/1/12 14-1011-28 Split System – Uncased Coil Enclosures Table COIL-4-A — 13 SEER Coil Enclosures Model Number Coils Used With Furnaces Flush on Both Sides Dimensions (in.) H x W x D Shipping Weight (Ibs.) BAYCLE14A1422A 4TXAA018BC 4TXAA024BC BAYCLE17A1722A 4TXAB025AS 4TXAB031AS 4TXAB036AS 4TXAB025BC 4TXAB031BC 4TXAB032BC 4TXAB036BC 4TXAB042BC 4TXAB048BC BAYCLE21A2130A 4TXAC037AS 4TXAC054AS 4TXAC037BC 4TXAC043BC 4TXAC044BC 4TXAC049BC 4TXAC060BC BAYCLE24A2430A 4TXAD065AS 4TXAD050BC 4TXAD061BC 4TXAD064BC 14½” Wide Furnace 22½ x 14½ x 21½ 12 17½” Wide Furnace 225/8 x 17½ x 21½ 14 21" Wide Furnace 30 x 21x 21½ 18 24½” Wide Furnace 30 x 24½ x 21½ 22 Split System – Cased/Uncased Heat Pump and Cooling Coils Table COIL-4-B — Features • • • • • • • • • • • • • • • • • 4TXC-CC4TXC-BC4TXA-BC4CXC-CC 4TXF All aluminum coil.................................................................................................................. ✔ ✔ ✔ ✔ ✔ 100% foil lined insulation...................................................................................................... ✔ ✔—✔ ✔ Internally checked non-bleed* thermal expansion valve with mechanical fittings (heat pump operation).......................................................................................................... ✔ ✔ ✔—✔ Non-Bleed* thermal expansion valve with mechanical fittings (cooling only operation)...... — — — ✔— Easy case attachment to furnace........................................................................................ ✔ ✔—✔— Upflow only application........................................................................................................ — — — ✔— Upflow/Downflow application............................................................................................... — — ✔ —— 4 way application - Upflow/Downflow/Horizontal (left/right)................................................. ✔ ✔ — —— Horizontal application with Bi-Direction airflow.................................................................... ————✔ Suction pressure service port.............................................................................................. ✔ ✔ ✔ ✔ ✔ Double sloped non-corrosive drain pan - UL rated 400°F................................................... ✔ ✔ ✔ ✔— Sloped non-corrosive drain pan........................................................................................... ————✔ Optimized for high efficiency with staged systems.............................................................. ✔———— Split inner and outer doors for easy coil inspection and cleaning........................................ ✔ ✔—✔— Painted galvanized steel cabinet to match furnace.............................................................. ✔ ✔—✔— Unpainted galvanized steel cabinet..................................................................................... ————✔ 10-year registered limited warranty on coil, & all other functional parts (Residential Use)**............................................................................................................. ✔ ✔ ✔ ✔ ✔ *Start kit may be required on outdoor unit. **Registered limited warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-544-8005; otherwise, American Standard Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. COIL-4 Effective 7/1/12 14-1011-28 Silver Series Cased & Uncased Cooling Only Coils Table COIL-5-A — 4FXC Cooling Only Cased Coils Model Number 4FXC Nom. Cap. Cooling Coil Refrigerant (Btuh) Type Control Outlet Dim. (in.) W/H x D 4FXCA024 24,000 ATXVNB1123/4 x 193/4 4FXCB024 24,000 ATXVNB1153/4 x 193/4 4FXCC024 24,000 ATXVNB1191/4 x 193/4 4FXCB036 36,000 ATXVNB1153/4 x 193/4 4FXCC036 36,000 ATXVNB1191/4 x 193/4 4FXCD036 36,000 ATXVNB1223/4 x 193/4 4FXCB042 42,000 ATXVNB1153/4 x 193/4 4FXCC042 42,000 ATXVNB1191/4 x 193/4 4FXCD042 42,000 ATXVNB1223/4 x 193/4 4FXCB048 48,000 MTXVNB1153/4 x 193/4 4FXCC048 48,000 MTXVNB1191/4 x 193/4 4FXCD048 48,000 MTXVNB1223/4 x 193/4 4FXCB060 60,000 MTXVNB1153/4 x 193/4 4FXCC060 60,000 MTXVNB1191/4 x 193/4 4FXCD060 60,000 MTXVNB1223/4 x 193/4 4FXCB061 60,000 MTXVNB1153/4 x 193/4 4FXCC061 60,000 MTXVNB1191/4 x 193/4 4FXCD061 60,000 MTXVNB1223/4 x 193/4 Overall Dim. (in.) H x W x D ShippingLine Size Weight OD OD (Ibs.) Gas Liq. 19 x 14.5 x 21.5 19 x 17.5 x 21.5 19 x 21 x 21.5 22.63 x 17.5 x 21.5 22.63 x 21 x 21.5 22.63 x 24.5 x 21.5 22.63 x 17.5 x 21.5 22.63 x 21 x 21.5 22.63 x 24.5 x 21.5 22.63 x 17.5 x 21.5 22.63 x 21 x 21.5 22.63 x 24.5 x 21.5 28.75 x 17.5 x 21.5 28.75 x 21 x 21.5 28.75 x 24.5 x 21.5 25 x 17.5 x 21.5 25 x 21 x 21.5 25 x 24.5 x 21.5 37 39 41 47 50 52 47 50 52 48 50 52 58 58 62 51 51 55 /4 /4 3 /4 3 /4 3 /4 3 /4 7 /8 7 /8 7 /8 7 /8 7 /8 7 /8 7 /8 7 /8 7 /8 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 3 3 3 Table COIL-5-B — 4FXA Cooling Only Uncased Coils Model Number 4FXA Nom. Cap. Cooling Coil Refrigerant (Btuh) Type Control 4FXAA02424,000ATXVNB1 4FXAB02424,000ATXVNB1 4FXAC02424,000ATXVNB1 4FXAN03636,000ATXVNB1 4FXAB03636,000ATXVNB1 4FXAC03636,000ATXVNB1 4FXAD03636,000ATXVNB1 4FXAN04242,000ATXVNB1 4FXAB04242,000ATXVNB1 4FXAC04242,000ATXVNB1 4FXAD04242,000ATXVNB1 4FXAB048 48,000MTXVNB1 4FXAC04848,000MTXVNB1 4FXAD04848,000MTXVNB1 4FXAB060 60,000MTXVNB1 4FXAC06060,000MTXVNB1 4FXAD06060,000MTXVNB1 4FXAB061 60,000MTXVNB1 4FXAC06160,000MTXVNB1 4FXAD06160,000MTXVNB1 1 Start Kit may be required on outdoor unit. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. COIL-5 Overall Dim. (in.) H x W x D 17.5 x 13 x 19.5 17.5 x 17 x 19.5 17.5 x 20 x 19.5 21.5 x 15 x 19.5 21.5 x 17 x 19.5 21.5 x 20 x 19.5 21.5 x 24 x 19.5 21.5 x 15 x 19.5 21.5 x 17 x 19.5 21.5 x 20 x 19.5 21.5 x 24 x 19.5 19.5 x 17 x 19.5 19.5 x 20 x 19.5 19.5 x 24 x 19.5 25.5 x 17 x 19.5 25.5 x 20 x 19.5 25.5 x 24 x 19.5 21.5 x 17 x 19.5 21.5 x 20 x 19.5 21.5 x 24 x 19.5 ShippingLine Size Weight OD OD (Ibs.) Gas Liq. 17 19 21 28 28 30 32 28 28 30 32 28 30 32 38 40 42 31 33 35 /4 3/8 /4 3/8 3 /4 3/8 3 /4 3/8 3 /4 3/8 3 /4 3/8 3 /4 3/8 3 /4 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 7 /8 3/8 3 3 Effective 7/1/12 14-1011-28 Silver Series Flat & Horizontal Cooling Only Coils Table COIL-6-A — 4FXFH Cooling Only Flat Coils 4FXFH Model Number Nom. Cap. Cooling Coil Refrigerant (Btuh) Type Control Outlet Dim. (in.) W/H x D Overall Dim. (in.) H x W x D 4FXFH024 4FXFH036 4FXFH048 4FXFH060 4FXFH063 30,000 48,000 48,000 60,000 63,000 16 x 21 30 x 21 30 x 21 30 x 21 34 x 21 24.5 x 24.5 x 10 24.5 x 36 x 10 24.5 x 36 x 10 24.5 x 36 x 10 24.5 x 37 x 10 FlatTXVNB1 FlatTXVNB1 FlatTXVNB1 FlatTXVNB1 FlatTXVNB1 ShippingLine Size Weight OD OD (Ibs.) Gas Liq. 27 33 40 40 45 /4 /4 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 3 3 3 Table COIL-6-B — 4FXCH Cooling Only Horizontal Coils Model Number Nom. Cap. Cooling Coil Refrigerant (Btuh) Type Control 4FXCH024 30,000 4FXCH036 36,000 4FXCH048 48,000 4FXCH060 60,000 4FXCH ATXVNB1 ATXVNB1 ATXVNB1 ATXVNB1 Outlet Dim. (in.) W/H x D Overall Dim. (in.) H x W x D 16.5 x 18.5 16.5 x 18.5 20.5 x 18.5 20.5 x 18.5 18.25 x 25 x 20.25 18.25 x 25 x 20.25 20.25 x 34.75 x 20.25 20.25 x 34.75 x 20.25 1 Start Kit may be required on outdoor unit. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. COIL-6 ShippingLine Size Weight OD OD (Ibs.) Gas Liq. 42 49 52 55 /4 /4 7 /8 7 /8 /8 /8 3 /8 3 /8 3 3 3 3 Effective 7/1/12 14-1011-28 Platinum SV, Gold ZM, Gold XI, Silver ZI, and Silver SI Convertible Gas Furnaces Airflow Directions Note: The forty inch (40") height condensing downflow/horizontal and upflow/horizontal furnaces may only be rotated onto their left side. Connection brackets for coil/furnace alignment are included with the furnaces. The apex of the coil may point into or away from the airflow. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-1 Effective 7/1/12 14-1011-28 Platinum SV – Modulating, Communicating Variable Speed Table FUR-2-A — Variable Speed, Communicating, Modulating Direct/Non-Direct Vent, Upflow/Horizontal Left Condensing Gas Furnace (115/1/60)457 Unit Model No. Airflow Output (Btuh) In Stage 3 Stage 1 ICS1 Tons High Stage/100% Low Stage/40%3 AFUE AUHMB060ACV3VA 3 AUHMB080ACV3VA 3 AUHMC100ACV4VA 4 AUHMD120ACV5VA 5 57,000 75,000 95,000 114,000 23,000 30,000 38,000 52,000 Flue Size (in) Uncrated Shipping Ignition Dimensions (in.) Weight Max Device H x W x D (Ibs.) Fuse* 95.02 2, 21/2, 3 95.02 2, 21/2, 3 95.0221/2, 3 95.023 6 40 x 171/2 x 28 6 40 x 171/2 x 28 6 40 x 21 x 28 6 40 x 241/2 x 28 Platinum SV Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. Direct/Non-Direct Vent 158 168 197 206 15 15 20 20 Filter Sizes 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 24 x 25 x 1 Table FUR-2-B — Variable Speed, Communicating, Modulating Direct/Non-Direct Vent, Downflow/Horizontal Right Condensing Gas Furnace (115/1/60)457 Unit Model No. Airflow Output (Btuh) In Stage 3 Stage 1 ICS1 Tons High Stage/100% Low Stage/40%3 AFUE ADHMB060ACV3VB3 ADHMB080ACV3VA3 ADHMC100ACV4VA4 ADHMD120ACV5VB5 57,000 74,000 95,000 114,000 22,800 30,000 38,000 45,600 Flue Size (in) Uncrated Shipping Ignition Dimensions (in.) Weight Max Device H x W x D (Ibs.) Fuse* 95.02 2, 21/2, 3 95.02 2, 21/2, 3 95.0221/2, 3 95.023 6 40 x 171/2 x 28 6 40 x 171/2 x 28 6 40 x 21 x 28 6 40 x 241/2 x 28 Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. Platinum SV Direct/Non-Direct Vent 160 168 185 206 15 15 20 20 Filter Sizes 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 24 x 25 x 1 Gold ZM – Two Stage Variable Speed Table FUR-2-C — Variable Speed Direct/Non-Direct Vent, Upflow/Horizontal Left Condensing Gas Furnace (115/1/60) Unit Model No. Airflow InOutput (Btuh) Tons Stage 2Stage 1 AUH2B060A9V3VA3 AUH2B080A9V3VA3 AUH2B080A9V4VA4 AUH2C100A9V4VA4 Gold ZM AUH2C100A9V5VA5 Direct/Non-Direct AUH2D120A9V5VA 5 Vent ICS1 AFUE Flue Uncrated Shipping Size Ignition Dimensions (in.) Weight Max (in) Device H x W x D (Ibs.) Fuse* 58,20037,830 97.02 2, 21/2, 3 77,60050,440 97.02 2, 21/2, 3 77,60050,440 97.02 2, 21/2, 3 96,70062,855 96.7221/2, 3 96,70062,855 96.7221/2, 3 116,040 75,426 96.723 6 6 6 6 6 6 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 21 x 28 40 x 241/2 x 28 158 168 170 197 199 206 15 15 20 20 20 20 Filter Sizes 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 20 x 25 x 1 24 x 25 x 1 Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. Table FUR-2-D — Variable Speed Direct/Non-Direct Vent, Downflow/Horizontal Right Condensing Gas Furnace (115/1/60) Unit Model No. Airflow In Output (Btuh) Tons Stage 2 Stage 1 ADH2B060A9V3VA 3 ADH2B080A9V3VA 3 ADH2B080A9V4VA 4 ADH2C100A9V4VA4 ADH2D120A9V5VA 5 Gold ZM Direct/Non-Direct 1 Isolated Combustion System. Vent 2Energy Star. 57,000 76,000 76,000 95,000 114,000 37,000 49,400 49,400 61,800 74,000 ICS1 AFUE Flue UncratedShipping Size Ignition Dimensions (in.) Weight Max (in) Device H x W x D (Ibs.) Fuse* 95.02 2, 21/2, 3 95.02 2, 21/2, 3 95.02 2, 21/2, 3 95.0221/2, 3 95.023 6 6 6 6 6 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 241/2 x 28 160 168 172 185 206 15 15 20 20 20 Filter Sizes 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 24 x 25 x 1 3Low stage is equal to 45% for AUH1D120 model and the ADH1D120 model. 4Furnace use in 24, non-communicating mode. 5Direct drive variable speed motor is an ECM constant airflow blower motor. 6Silicon Nitride 7Must use ACONT900 or AZONE950 control in communicating mode. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Filters are not shipped with furnace. Note: Variable speed furnaces should not be twinned and are not approved for twinning applications For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-2 Effective 7/1/12 14-1011-28 Silver ZI – Single Stage Table FUR-3-A — Direct/Non-Direct Vent, Upflow/Horizontal Left Condensing Gas Furnace (115/1/60) Unit Model No. AirflowNominal In Output ICS1 Tons (Btuh) AFUE Flue Size Ignition (in) Device AUH1B040A9241A 2 38,000 95.0 2, 21/2, 3 AUH1B060A9361A 3 57,000 95.0 2, 21/2, 3 AUH1B080A9421A31/276,000 95.0 3 AUH1C080A9601A 576,00095.0 3 AUH1C100A9481A 492,15095.0 3 Silver ZI AUH1D100A9601A 592,15095.0 3 Direct/Non-Direct AUH1D120A9601A 5104,50095.0 3 Vent 2 2 2 2 2 2 2 Uncrated Dimensions (in.) H x W x D Shipping Weight (Ibs.) Max Fuse* Filter** Sizes 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 21 x 28 40 x 241/2 x 28 40 x 241/2 x 28 139 150 158 171 171 197 205 15 15 15 20 20 20 20 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 20 x 25 x 1 24 x 25 x 1 24 x 25 x 1 Table FUR-3-B — Direct/Non-Direct Vent, Downflow/Horizontal Right Condensing Gas Furnace (115/1/60) Unit Model No. AirflowNominal In Output ICS1 Tons (Btuh) AFUE ADH1B040A9241A 238,00095.0 ADH1B065A9421A31/257,000 95.0 ADH1C085A9481A 4 76,000 95.0 ADH1D110A9601A 5 104,500 95.0 Flue Size Ignition (in) Device 2,21/2,3 2,21/2,3 21/2,3 21/2,3 Uncrated Dimensions (in.) H x W x D Shipping Weight Max2Filter** (Ibs.) Fuse* Sizes 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 241/2 x 28 2 2 2 2 155 168 185 206 15 15 15 20 14x20x1 14x20x1 14x20x1 16x20x1 1 Isolated Combustion System. 2Silicon Nitride Silver ZI Direct/Non-Direct * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Filters are not shipped with furnace. Vent Gold XI - Single Stage with High Efficiency Motor Table FUR-3-C — Direct/Non-Direct Vent, Upflow/Horizontal Left Condensing Gas Furnace with Filter Unit Model No. Airflow NominalFlueUncrated Shipping In Output ICS1 Size Ignition Dimensions (in.) Weight Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Max Fuse* Filter Sizes AUH1B040A9H21A 2 38,000 95.0 2, 21/2, 3 AUH1B060A9H31A 3 57,000 95.0 2, 21/2, 3 AUH1B080A9H31A 3 76,00095.0 3 AUH1C100A9H41A31/2 92,15095.0 3 AUH1D120A9H51A 5 104,50095.0 3 2 2 2 2 2 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 241/2 x 28 139 150 158 171 205 15 15 15 15 20 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 24 x 25 x 1 2 ADH1B065A9H31A 3 ADH1C085A9H41A4 ADH1D110A9H51A 5 2 2 2 2 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 241/2 x 28 145 158 171 205 15 15 15 20 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 16 x 20 x 1 (2) 16 x 20 x 1 Gold XI Direct/Non-Direct ADH1B040A9H21A Vent 38,000 95.0 2, 21/2, 3 57,000 95.0 2, 21/2, 3 76,00095.0 21/2, 3 104,50095.0 21/2, 3 1 Isolated Combustion System. 2Silicon Nitride. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-3 Effective 7/1/12 14-1011-28 Freedom 90 – Single Stage with High Efficiency Motor Table FUR-4-A —Direct/Non-Direct Vent, Upflow/Horizontal Left Condensing Gas Furnace (115/1/60) with Filter Unit Model No. Freedom 90 Direct/Non-Direct Vent AirflowNominal In Output ICS1 Tons (Btuh) AFUE Flue Size Ignition (in) Device Uncrated Shipping Dimensions (in.) Weight H x W x D (Ibs.) Max Fuse* Filter Sizes 15 15 15 20 20 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 24 x 25 x 1 PHasED out AUX1B040A9H21B 2 38,000 92.1 2, 21/2, 3 AUX1B060A9H31B 3 56,000 92.1 2, 21/2, 3 AUX1B080A9H31B 3 74,000 92.1 2, 21/2, 3 AUX1C100A9H41B4 94,00092.1 21/2, 3 AUX1D120A9H51B 5 113,00092.1 21/2, 3 Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 241/2 x 28 139 150 158 171 205 Table FUR-4-B — Direct/Non-Direct Vent, Downflow/Horizontal Right Condensing Gas Furnace (115/1/60) with Filter Unit Model No. AirflowNominal In Output ICS1 Tons (Btuh) AFUE Flue Size Ignition (in) Device Uncrated Shipping Dimensions (in.) Weight H x W x D (Ibs.) Max Fuse* Filter Sizes PHasED out ADX1B040A9H21B 2 38,000 91.0 2, 21/2, 3 ADX1B060A9H31B 3 56,000 91.0 2, 21/2, 3 ADX1B080A9H31B 3 74,000 91.0 2, 21/2, 3 ADX1C100A9H41B4 94,000 91.0 21/2, 3 ADX1D120A9H51B 5 112,00091.0 21/2, 3 Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 241/2 x 28 145 155 168 185 206 15 15 20 20 20 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 16 x 20 x 1 (2) 16 x 20 x 1 1Isolated Combustion System. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Filters are not shipped with furnace. Silver SI – Single Stage Table FUR-4-C — Direct/Non-Direct Vent, Upflow/Horizontal Left Condensing Gas Furnace (115/1/60) Unit Model No. Silver SI AirflowNominal In Output Tons (Btuh) AFUE AUC1B040A9241A 2 AUC1B060A9361A 3 AUC1B080A9421A31/2 AUC1C100A9481A4 AUC1D100A9601A5 AUC1D120A9601A5 38,000 92.1 56,000 92.1 74,000 92.1 94,000 92.1 93,000 92.1 113,000 92.1 Flue Size Ignition (in) Device 2, 21/2, 3 Silicon Nitride 2, 21/2, 3 Silicon Nitride 2, 21/2, 3 Silicon Nitride 21/2, 3 Silicon Nitride 21/2, 3 Silicon Nitride 21/2, 3Silicon Nitride Uncrated Shipping Dimensions (in.) Weight H x W x D (Ibs.) 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 241/2 x 28 40 x 241/2 x 28 139 150 158 171 197 205 Max Fuse* Filter** Sizes 15 15 15 20 20 20 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 24 x 25 x 1 24 x 25 x 1 Table FUR-4-D — Direct/Non-Direct Vent, Downflow/Horizontal Right Condensing Gas Furnace (115/1/60) Unit Model No. AirflowNominal In Output Tons (Btuh) AFUE ADC1B040A9241A 2 ADC1B060A9361A 3 ADC1B080A9421A31/2 ADC1C100A9481A4 ADC1D120A9601A5 Flue Size Ignition (in) Device Uncrated Shipping Dimensions (in.) Weight H x W x D (Ibs.) 38,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 56,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 74,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 93,000 92.1 21/2, 3 Silicon Nitride 40 x 21 x 28 112,000 92.1 21/2, 3Silicon Nitride 40 x 241/2 x 28 145 155 168 185 206 Max Fuse* Filter** Sizes 15 15 15 20 20 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 16 x 20 x 1 (2) 16 x 20 x 1 * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Filters are not shipped with furnace. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-4 Effective 7/1/12 14-1011-28 Platinum SV, Gold ZM, Gold XI, Silver ZI, and Silver SI Convertible Gas Furnaces Table FUR-5-A — Features • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • AUHM/ ADHM Modulating 1 or 2 Pipe AUH2/ AUH1-H/AUX1-H/AUH1/ AUC1/ ADH2 ADH1-HADX1-HADH1 ADC1 2 Stage 1 Stage 1 Stage 1 Stage 1 Stage 1 or 2 Pipe 1 or 2 Pipe 1 or 2 Pipe 1or 2 Pipe 1 or 2 Pipe Variable Speed Variable Speed Variable Speed High Efficiency Comfort-R™ enhanced mode (cooling)..................................................... AccuLink™ system2............................................................................... Adjustable heating fan off timing................................................................ Alternate bottom/left/right return air (upflow models only)............................. Blower door safety switch.......................................................................... Bottom panel (upflow models only)............................................................. Cleanable/Reusable high velocity filters.................................................... Complete front service access.................................................................. Direct drive, multi-speed (PSC) blower motor........................................... Direct drive, multi-speed ECM blower motor (high efficiency)*................... Direct drive, variable speed ECM blower motor**...................................... Downflow horizontal right (downflow models only)....................................... Dual PVC pipe venting (1 or 2 pipe option)............................................... Two stage combination gas valve and regulator........................................ One stage combination gas valve and regulator....................................... Modulating gas valve and regulator........................................................... Gasketed blower door................................................................................ Heavy gauge reinforced wrap-around steel cabinet....................................... Humidifier/EAC hook-up capability............................................................ Inner blower door panel (downflow models only)...................................... Insulated blower compartment 4 sides...................................................... Integrated solid state control w/self diagnostics........................................ Left/right condensate drain capability in vertical application..................... Service diagnostics with faults reported at the user interface.................. Lite Port™/Stored diagnostics..................................................................... Manual reset flame roll out switches.......................................................... Mobile home approved w/BAYMFGH100A................................................ Multi-port in shot burners........................................................................... Painted cabinet single color....................................................................... Painted cabinet two tone color................................................................... Perfect fit door latches (upflow models only)............................................... Service diagnostic capabilities................................................................... Slide out blower assembly......................................................................... Side return duct starter tabs (upflow models only)..................................... Silicon Nitride hot surface igniter with adaptive heat up............................ Single wire twinning................................................................................... Solid burner door (quiet operation)............................................................ 20 gauge aluminized steel heat exchanger............................................... 24 volt secondary fuse............................................................................... Variable heating blower speeds................................................................. Two heating blower speeds........................................................................ Type 29-4C™ stainless steel secondary heat exchanger............................. Upflow horizontal left (upflow models only)............................................... Variable speed venter motor...................................................................... Registered limited lifetime heat exchanger warranty and 10-year on all other functional parts (Residential Use)1.................. Optional extended warranties available................................................ ✔ ✔ — ——— ✔ — — ——— ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ — ✔ ✔— — — — ✔ ✔ ✔ ✔ ✔ ✔ — — — ✔ ✔ ✔ — — ✔ ——— ✔ ✔ — ——— ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ — ✔ — ✔ — — — — ✔—✔ ✔ ✔ — — ——— ✔ ✔ ✔ ✔ ✔ — ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ — ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ — — ——— ✔ ✔ ✔ ✔ ✔ ✔ ✔— — ——— — ✔ ✔ ✔—— ✔ — — ——— — ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ — — — — — ✔ ✔ ✔ ✔ ✔ ✔ — ✔ — — ——— ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ — — — ✔ ✔ ✔ — ✔ ✔ ✔ ✔ ✔ — ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ — ——— —— — ✔—— ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ — ✔—— PHasED out Airflow Directions: Downflow models when placed in horizontal position provide left to right airflow. Upflow models when placed in horizontal position provide right to left airflow. ✔ ✔ ✔ ✔ ✔ ✔ — ✔ ✔ ✔ ✔ ✔ 1Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. 2Field configurable to 24V non-communicating mode. Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. *Constant torque ECM (electronically commutated motor). **Constant airflow ECM (electronically commutated motor). For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-5 Effective 7/1/12 14-1011-28 Platinum SV, Gold ZM, Gold XI, Silver ZI, and Silver SI Convertible Gas Furnaces Airflow Directions: Downflow models when placed in horizontal position provide AUHM/ADHM AUH2/ADH2 left to right airflow. Upflow models when placed in horizontal Modulating 2 Stage position provide right to left airflow. 1 or 2 Pipe 1 or 2 Pipe Table FUR-6-A — Optional Accessories Variable Speed Variable Speed Model Number Description Shipping Weight BAYBASE205...............Downflow subbase for downflow models only.............................. 8.............................................. ✔ ✔ BAYFLTR200................External side filter rack.................................................................. 5.............................................. ✔ ✔ BAYFLTR203................Filter kit horiz conversion for 17.5" cabinet................................... 3.............................................. ✔ ✔ BAYFLTR204................Filter kit horiz conversion for 21" cabinet..................................... 3.............................................. ✔ ✔ BAYFLTR205................Filter kit horiz conversion for 24.5" cabinet .................................. 3.............................................. ✔ ✔ BAYFLTR3171 ...........Cleanable filter for 17.5" cabinet upflow only............................... 2.............................................. ✔ ✔ BAYFLTR3211 ...........Cleanable filter for 21" cabinet upflow only ................................. 2.............................................. ✔ ✔ BAYFLTR3241 ...........Cleanable filter for 24.5" cabinet upflow only............................... 2.............................................. ✔ ✔ BAYLPKT210B.............Propane conversion kit ................................................................... 1.............................................. — ✔ BAYLPKT220B.............Propane conversion kit ................................................................... 2.............................................. ✔— BAYLPSS210B ............LP Kit with Stainless Steel Burners.............................................. 1.............................................. — ✔ BAYLPSS220B.............LP Kit with Stainless Steel Burners.............................................. 2.............................................. ✔— BAYMFGH100A...........Manufactured/mobil home kit ...................................................... 2.............................................. — ✔ BAYRACK960A............Filter rack kit for upflow models only (internal)2.......................... 5.............................................. ✔ ✔ BAYAIR30AVENTA.......Concentric vent kit for 2, 2½ and 3" ven system ......................... 11............................................. ✔ ✔ BAYVENT200B............Sidewall vent Termination Kit fo Direct vent furnaces................... 2.............................................. ✔ ✔ BAYVENT500A............Side vent kit for downflow models only......................................... 3.............................................. ✔ ✔ BAYACCECOMM101...AccuClean™ hookup kit for communicating furnaces.................. 1.............................................. ✔— 1Contains one (1) high velocity filter. 2Internal filter rack for side or bottom return air. Includes 17 x 25" cleanable filter for use in side return applications. Bottom return applications require different sizes of filters which are not included. Airflow requirements over 1800 CFM require filters on both sides or a side and bottom or bottom only. Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. Airflow Directions: Table FUR-6-B — Optional Accessories AUH1-H/ AUX1-H/ADX1-HAUH1/ADH1/ AUC1/ADC1 ADH1-H 1 Stage AUX1/ADX1 1 Stage 2 Stage 1 or 2 Pipe 1 Stage 1 or 2 Pipe 1 or 2 Pipe High Efficiency 1 or 2 Pipe Model Number Description Shipping Weight BAYBASE205............Downflow subbase for downflow models only....................8.............................. ✔ BAYFLTR200.............External side filter rack.......................................................5.............................. ✔ BAYFLTR203.............Filter kit horiz conversion for 17.5" cabinet........................3.............................. ✔ BAYFLTR204.............Filter kit horiz conversion for 21" cabinet..........................3.............................. ✔ BAYFLTR205.............Filter kit horiz conversion for 24.5" cabinet .......................3.............................. ✔ BAYFLTR206.............Filter kit ..............................................................................2.............................. — BAYFLTR3171 ........Cleanable filter for 17.5" cabinet upflow only....................2.............................. ✔ BAYFLTR3211 ........Cleanable filter for 21" cabinet upflow only ......................2.............................. ✔ BAYFLTR3241 ........Cleanable filter for 24.5" cabinet upflow only....................2.............................. ✔ BAYLPKT210B..........Propane conversion kit ........................................................1.............................. ✔ BAYLPSS210B .........LP Kit with Stainless Steel Burners....................................1.............................. ✔ BAYMFGH100A........Manufactured/mobil home kit ............................................2.............................. ✔ BAYRACK960A.........Filter rack kit for upflow models only (internal)2...............5.............................. ✔ BAYAIR30AVENTA....Concentric vent kit for 2, 2½ and 3" vent system .............11............................. ✔ BAYVENT200B.........Sidewall vent Termination Kit fo Direct vent furnaces........2.............................. ✔ BAYVENT500A.........Side vent kit for downflow models only..............................3.............................. ✔ ✔ ✔ ✔ ✔ ✔ — ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ PHasED out Downflow models when placed in horizontal position provide left to right airflow. Upflow models when placed in horizontal position provide right to left airflow. ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ 1Contains one (1) high velocity filter. 2Internal filter rack for side or bottom return air. Includes 17 x 25" cleanable filter for use in side return applications. Bottom return applications require different sizes of filters which are not included. Airflow requirements over 1800 CFM require filters on both sides or a side and bottom or bottom only. Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-6 Effective 7/1/12 14-1011-28 Special Use Furnace Accessories Table FUR-7-A — High Altitude Pressure Switch 90% Model Number Description Used With BAYHALT225 BAYHALT226 BAYHALT227 BAYHALT228 BAYHALT230 BAYHALT231 BAYHALT232 BAYHALT233 BAYHALT234 BAYHALT241 BAYHALT245 BAYHALT246 BAYHALT247 BAYHALT248 BAYHALT249 1 Switch 1 Switch 1 Switch 1 Switch 1 Switch 1 Switch 1 Switch 1 Switch 1 Switch 1 Switch 2 Switches 2 Switches 2 Switches 1 Switch 1 Switch Shipping Weight AUC080,100C948,120C,ADC080,120C AUC,ADC060C AUC100C948 AUC/ADC040C AUX/ADX040C,AUX1B040,D100/ADX1B040 AUX060C,AUX1060C AUX080C,AUX1B080C AUX100,120C/ADX080,120C,AUX1C100,D120/ADX1B080,D120 ADX100C,ADX1C100 ADX060C,ADX1B060 ADX/AUX/ADY/AUY060-R ADX/AUX/ADY/AUY080,100-R ADX/AUX/ADY/AUY120-R AUD1/ADD1,AUE1/ADE AUD2,AUD-R-K,ADD-R-F,ADD2 Table FUR-7-B — High Altitude Pressure Switch 90% Model Number Description Used With 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Shipping Weight BAYSWT01AHALTA 1 Switch AUC1B040,AUC1D100,ADC1B040,AUX1B040, 2 AUX1D100,ADX1B040,AUH1B040,ADH1B040,ADH1C0852 BAYSWT02AHALTA 1 Switch AUC1B060,AUX1B060 2 BAYSWT03AHALTA 1 Switch AUC1B080,AUX1B080 2 BAYSWT04AHALTA 1 Switch AUC1C100,AUC1D120,ADC1B080, 2 ADC1C100,ADC1D120,AUX1C100,AUX1D120, ADX1B080,ADX1D120,AUH1B060 BAYSWT05AHALTA 1 Switch ADX1C100,AUH1B080,AUH1C100,ADH1D110 2 BAYSWT06AHALTA 1 Switch ADC1B060,ADX1B060 2 BAYSWT07AHALTA 1 Switch AUH3/AUHMB060,ADH3/ADHMB060,AUX2B060,ADX2B060, 2 AUY060R,ADY060R BAYSWT08AHALTA 1 Switch AUX2B080,AUX2C100,ADX2B080,ADX2C100,AUY120R,ADY120R, 2 AUH2B080,ADH2B080,AUH2C100,ADH2C100,AUH2D120, ADH2D120,AUH3/AUHMD120,ADH3/ADHMD120 BAYSWT09AHALTA 1 Switch AUX2D120,ADX2D120,AUY080R,ADY080R,AUY100R, 2 ADY100R,AUH3/AUHMB080,ADH3/ADHMB080,AUH3/AUHMC100, ADH/ADHM3C100 BAYSWT10AHALTA 1 Switch AUH2B060A,ADH2B060A 2 BAYSWT11AHALTA 1 Switch AUH1C080 2 BAYSWT12AHALTA 1 Switch ADH1B065 2 BAYSWT01AMALTB 1 Switch AUX1 2 The following changes occurred beginning with serial number 6151: 1. All 2 stage furnace changed from two separate pressure switches to one piggy back switch. 2. The high altitude pressure switches are now piggy back. 3. The new piggy back switches are not interchangeable with the original two switch design. 4. The pressure switch mounting plate is different for the piggy back switches. Table FUR-7-C — Dual Fuel Heat Pump Control Kit12 Case Height Used With TAYPLUS103A.............. Heat Pump Control Kit.............Gas, LP., Oil and Electric Furnaces TAYSTAT250B............... Outdoor Thermostat.................TAYPLUS103A for Restricted Mode Model Number 1 Factory wired for non-restricted mode, can be wired for restricted mode. 2 Applicable for all furnaces with 35 VA or larger low voltage transformer (separate high voltage power not required). Bonnet Switch TAYPLUS103A For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-7 Effective 7/1/12 14-1011-28 Platinum SV, Gold SV, Gold SM, Silver XI, Silver SI+, and Silver SI Gas Furnaces Airflow Directions Note: The non-condensing, forty inch (40") height furnaces may be laid on either side for horizontal application. Connection brackets for coil/furnace alignment are included with the furnaces. The apex of the coil may point into or away from the airflow. *Freedom 80 furnace with integrated AccuClean™ technology is upflow or upflow/horizontal application only. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-8 Effective 7/1/12 14-1011-28 Platinum SV – Two Stage Variable Speed (24 Volt Mode) Table FUR-9-A — Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)23 Unit Model No. Platinum SV Airflow InOutput (Btuh) Tons Stage 2 Stage 1 AUD2B060ACV32A3 AUD2B080ACV32A3 AUD2C080ACV42A4 AUD2B100ACV32A3 AUD2C100ACV52A5 AUD2D120ACV52A5 AUD2D140ACV52A5 48,000 31,200 64,000 41,600 64,000 41,600 80,000 52,000 79,000 52,000 97,000 62,400 111,00 72,800 FlueUncrated Shipping ICS1 Size Ignition Dimensions (in.) Weight Max AFUE (in) Device H x W x D (Ibs.) Fuse* 80.0 80.0 80.0 80.0 80.0 80.0 80.0 4 4 4 4 4 4 4 Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 241/2 x 28 40 x 241/2 x 28 136 142 166 142 166 193 197 15 15 20 15 20 20 20 Filter Sizes 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 24 x 25 x 1 24 x 25 x 1 Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. Table FUR-9-B — Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)23 Unit Model No. Airflow InOutput (Btuh) Tons Stage 2 Stage 1 ADD2B060ACV32A3 ADD2B080ACV32A3 ADD2C100ACV52A5 ADD2D120ACV52A5 Platinum SV 48,000 31,200 63,000 41,600 81,000 52,000 95,000 62,400 FlueUncrated Shipping ICS1 Size Ignition Dimensions (in.) Weight Max AFUE (in) Device H x W x D (Ibs.) Fuse* 80.0 80.0 80.0 80.0 4 4 4 4 Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 241/2 x 28 140 146 166 197 Filter Sizes 15 (2) 14 x 20 x 1 15 (2) 14 x 20 x 1 20 (2) 16 x 20 x 1 20 (2) 16 x 20 x 1 Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. 1 Isolated Combustion System. 2Must use ACONT900 or AZONE950 control in communicating mode. 3Field convertible to 24V non-communicating. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Filters are not shipped with furnace. Gold SV – Two Stage Variable Speed Table FUR-9-C — Upflow/Horizontal Left or Right Induced Draft Gas Unit Model No. Gold SV Airflow Flue InOutput (Btuh) Size Ignition Tons Stage 2 Stage 1 AFUE (in) Device AUD2B060A9V3VA 3 48,00031,200 AUD2B080A9V3VA 3 64,00041,600 AUD2C080A9V4VA 4 64,00041,600 AUD2C080B9V4VA14 64,000 41,600 AUD2B100A9V3VA 3 80,00052,000 AUD2C100A9V5VA 5 79,00052,000 AUD2C100B9V5VA15 79,000 52,000 AUD2D120A9V5VA 5 97,00062,400 AUD2D120B9V5VA15 97,000 62,400 AUD2D140A9V5VA 5 111,00072,800 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 4 4 4 4 4 4 4 4 4 4 Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Furnace (115/1/60) Uncrated Shipping Dimensions (in.) Weight Max H x W x D (Ibs.) Fuse* 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 21 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 21 x 28 40 x 241/2 x 28 40 x 241/2 x 28 40 x 241/2 x 28 136 142 166 166 142 166 166 193 193 197 15 15 20 20 15 20 20 20 20 20 Filter Sizes 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 20 x 25 x 1 24 x 25 x 1 24 x 25 x 1 24 x 25 x 1 Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. Table FUR-9-D — Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60) Unit Model No. Airflow Flue InOutput (Btuh) Size Ignition Tons Stage 2 Stage 1 AFUE (in) Device ADD2B060A9V3VA ADD2B080A9V3VA ADD2C100A9V5VA ADD2D120A9V5VA Gold SV 3 3 5 5 48,00031,200 63,00041,600 81,00052,000 95,00062,400 80.0 80.0 80.0 80.0 4 4 4 4 Uncrated Shipping Dimensions (in.) Weight Max H x W x D (Ibs.) Fuse* Silicon Nitride 40 x 171/2 x 28 Silicon Nitride 40 x 171/2 x 28 Silicon Nitride 40 x 21 x 28 Silicon Nitride 40 x 241/2 x 28 140 146 166 197 Filter Sizes 15 (2) 14 x 20 x 1 15(2) 14 x 20 x 1 20(2) 16 x 20 x 1 20(2) 16 x 20 x 1 1 Model has high efficiency blower. Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-9 Effective 7/1/12 14-1011-28 Gold SM – Two Stage Table FUR-10-A — Upflow/Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60) Unit Model No. Gold SM AUD2A040A9242A AUD2A060A9362A AUD2B060A9362A AUD2B080A9362A AUD2B080A9482A AUD2B100A9362A AUD2C100A9482A AUD2C100A9602A AUD2D100A9602A AUD2C120A9542A AUD2D120A9602A AUD2D140A9602A Airflow Flue InOutput (Btuh) ICS1 Size Ignition Tons Stage 2 Stage 1 AFUE (in) Device 2 3 3 3 4 3 4 5 5 5 5 5 32,000 20,800 80.0 47,000 31,200 80.0 47,000 31,200 80.0 63,000 41,600 80.0 63,000 41,600 80.0 79,000 52,000 80.0 79,000 52,000 80.0 80,000 52,000 80.0 80,000 52,000 80.0 95,000 62,400 80.0 95,000 62,400 80.0 112,00072,800 80.0 4 4 4 4 4 4 4 4 4 4 4 4 Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride UncratedShipping Dimensions (in.) Weight Max H x W x D (Ibs.) Fuse* 40 x 141/2 x 28 40 x 141/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 21 x 28 40 x 241/2 x 28 40 x 21 x 28 40 x 241/2 x 28 40 x 241/2 x 28 119 127 132 142 142 151 162 162 175 176 186 192 15 15 15 15 15 15 15 20 20 20 20 20 Filter** Sizes 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 20 x 25 x 1 24 x 25 x 1 20 x 25 x 1 24 x 25 x 1 24 x 25 x 1 Table FUR-10-B — Downflow/Horizontal Left or Right Induced Draft (115/1/60) Unit Model No. Gold SM ADD2A040A9242A ADD2A060A9362A ADD2B060A9362A ADD2B080A9362A ADD2B100A9482A ADD2C100A9482A ADD2C100A9602A ADD2D120A9602A ADD2D140A9602A Airflow Flue InOutput (Btuh) ICS1 Size Ignition Tons Stage 2 Stage 1 AFUE (in) Device 2 3 3 3 4 4 5 5 5 32,000 20,800 80.0 47,000 31,200 80.0 48,000 31,200 80.0 64,000 41,600 80.0 79,000 52,000 80.0 79,000 52,000 80.0 79,000 52,000 80.0 94,000 62,400 80.0 112,00072,800 80.0 4 4 4 4 4 4 4 4 4 Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride UncratedShipping Dimensions (in.) Weight Max H x W x D (Ibs.) Fuse* 40 x 141/2 x 28 40 x 141/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 21 x 28 40 x 241/2 x 28 40 x 241/2 x 28 125 135 140 152 157 166 168 189 196 15 15 15 15 15 15 20 20 20 Filter** Sizes (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 16 x 20 x 1 (2) 16 x 20 x 1 (2) 16 x 20 x 1 (2) 16 x 20 x 1 1 Isolated Combustion System. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Filters are not shipped with furnace. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-10 Effective 7/1/12 14-1011-28 Silver XI – Single Stage with High Efficiency Motor Table FUR-11-A — Upflow Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60) Unit Model No. Silver XI AirflowNominal Flue In Output Size Ignition Tons (Btuh) AFUE (in.) Device AUD1A040A9H21B2 AUD1B060A9H31B3 AUD1B080A9H31B3 AUD1C080A9H41B4 AUD1B100A9H31B3 AUD1C100A9H51B5 AUD1D120A9H51B5 AUD1D140A9H51B5 32,000 80.0 4Silicon Nitride 47,000 80.0 4Silicon Nitride 63,000 80.0 4Silicon Nitride 64,000 80.0 4 Silicon Nitride 79,000 80.0 4Silicon Nitride 79,000 80.0 4 Silicon Nitride 96,000 80.0 4 Silicon Nitride 111,000 80.0 4 Silicon Nitride Uncrated Dimensions (in.) H x W x D Shipping Weight (Ibs.) Max Fuse* Filter Sizes 40 x 141/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 241/2 x 28 40 x 241/2 x 28 119 127 142 142 151 162 186 193 15 15 15 20 20 20 20 20 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 17 x 25 x 1 20 x 25 x 1 24 x 25 x 1 24 x 25 x 1 Table FUR-11-B — Downflow Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60) Unit Model No. AirflowNominal Flue In Output Size Ignition Tons (Btuh) AFUE (in.) Device ADD1B060A9H31B3 ADD1B080A9H31B3 ADD1C100A9H51B5 ADD1D120A9H51B5 Silver XI 48,000 64,000 81,000 96,000 80.0 4 Silicon Nitride 80.0 4 Silicon Nitride 80.0 4 Silicon Nitride 80.0 4 Silicon Nitride Uncrated Dimensions (in.) H x W x D Shipping Weight (Ibs.) Max Fuse* Filter Sizes 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 241/2 x 28 129 146 167 189 15 15 20 20 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 16 x 20 x 1 (2) 16 x 20 x 1 Silver SI+ – Single Stage Table FUR-11-C — Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60) Unit Model No. Silver SI+ AirflowNominal Flue In Output Size Ignition Tons (Btuh) AFUE (in.) Device AUD1A040A9241A 2 AUD1A040A9301A21/2 AUD1A060A9241A 2 AUD1A060A9361A 3 AUD1B060A9361A 3 AUD1B080A9241A 2 AUD1B080A9361A 3 AUD1B080A9481A 4 AUD1C080A9601A 5 AUD1B100A9361A 3 AUD1B100A9451A 4 AUD1C100A9481A 4 AUD1C100A9601A 5 AUD1D100A9721A 6 AUD1C120A9541A 5 AUD1D120A9601A 5 AUD1D140A9601A 5 32,000 32,000 47,000 47,000 47,000 64,000 63,000 64,000 64,000 79,000 80,000 79,000 79,000 80,000 96,000 96,000 111,000 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Uncrated Dimensions (in.) H x W x D Shipping Weight (Ibs.) Max Fuse* Filter** Sizes 40 x 141/2 x 28 40 x 141/2 x 28 40 x 141/2 x 28 40 x 141/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 21 x 28 40 x 241/2 x 28 40 x 21 x 28 40 x 241/2 x 28 40 x 241/2 x 28 119 122 124 127 132 139 142 142 154 151 153 162 162 175 176 186 193 15 15 15 15 15 15 15 15 20 15 15 15 20 20 20 20 20 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 20 x 25 x 1 24 x 25 x 1 20 x 25 x 1 24 x 25 x 1 24 x 25 x 1 Table FUR-11-D — Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60) Unit Model No. Silver SI+ ADD1A040A9241A ADD1A060A9241A ADD1A060A9361A ADD1B060A9361A ADD1B080A9361A ADD1B080A9451A ADD1B100A9451A ADD1C100A9481A ADD1C100A9541A ADD1C120A9541A ADD1D120A9601A ADD1D140A9601A AirflowNominal Flue In Output Size Ignition Tons (Btuh) AFUE (in.) Device 2 2 3 3 3 4 4 4 5 5 5 5 31,000 48,000 48,000 48,000 64,000 64,000 80,000 80,000 81,000 96,000 96,000 113,000 78.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 4 4 4 4 4 4 4 4 4 4 4 4 Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Uncrated Dimensions (in.) H x W x D Shipping Weight (Ibs.) Max Fuse* 40 x 141/2 x 28 40 x 141/2 x 28 40 x 141/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 21 x 28 40 x 21 x 28 40 x 241/2 x 28 40 x 241/2 x 28 119 129 129 134 146 146 156 166 167 177 189 196 15 15 15 15 15 15 15 15 20 20 20 20 Filter** Sizes (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 14 x 20 x 1 (2) 16 x 20 x 1 (2) 16 x 20 x 1 (2) 16 x 20 x 1 (2) 16 x 20 x 1 (2) 16 x 20 x 1 * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Filters are not shipped with furnace. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-11 Effective 7/1/12 14-1011-28 Silver SI – Single Stage Table FUR-12-A — Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60) Unit Model No. Sliver SI AirflowNominal Flue In Output Size Ignition Tons (Btuh) AFUE (in.) Device AUE1A040A9241A 2 31,000 AUE1A060A9241A 2 47,000 AUE1A060A9361A 3 47,000 AUE1B060A9361A 3 47,000 AUE1B080A9361A 3 63,000 AUE1B080A9481A 4 64,000 AUE1B100A9361A 3 79,000 AUE1C100A9481A 4 79,000 AUE1C100A9601A 5 79,000 AUE1D120A9601A 5 96,000 AUE1D140A9601A 5 111,000 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 4 4 4 4 4 4 4 4 4 4 4 Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Uncrated Dimensions (in.) H x W x D Shipping Weight (Ibs.) Max Fuse* Filter** Sizes 40 x 141/2 x 28 40 x 141/2 x 28 40 x 141/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 21 x 28 40 x 241/2 x 28 40 x 241/2 x 28 119 124 127 132 142 142 151 162 162 186 193 15 15 15 15 15 15 15 15 20 20 20 16 x 25 x 1 16 x 25 x 1 16 x 25 x 1 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 17 x 25 x 1 20 x 25 x 1 20 x 25 x 1 24 x 25 x 1 24 x 25 x 1 Table FUR-12-B — Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60) Unit Model No. AirflowNominal Flue In Output Size Ignition Tons (Btuh) AFUE (in.) Device ADE1A060A9361A 3 ADE1B060A9361A 3 ADE1B080A9451A 4 ADE1B100A9451A 4 ADE1C100A9601A5 ADE1D120A9601A5 48,000 48,000 64,000 80,000 81,000 96,000 80.0 80.0 80.0 80.0 80.0 80.0 4 4 4 4 4 4 Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Silicon Nitride Uncrated Dimensions (in.) H x W x D Shipping Weight (Ibs.) 40 x 141/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 171/2 x 28 40 x 21 x 28 40 x 241/2 x 28 129 134 146 156 167 189 Max Fuse* Filter** Sizes 15 (2) 14 x 20 x 1 15 (2) 14 x 20 x 1 15 (2) 14 x 20 x 1 15 (2) 14 x 20 x 1 20 (2) 16 x 20 x 1 20 (2) 16 x 20 x 1 * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. ** Filters are not shipped with furnace. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-12 Effective 7/1/12 14-1011-28 Platinum SV, Gold SV, Gold SM, Silver XI, Silver SI+, and Silver SI Convertible Gas Furnaces AUD2-ACV/AUD2-9V AUD2/ AUD1-H/ AUD1/ AUE1/ ADD2-ACV ADD2-9V ADD2 ADD1-H ADD1 ADE1 2 Stage 2 Stage 2 Stage 1 Stage 1 Stage 1 Stage 1 or 2 Pipe 3 High Efficiency 3 Table FUR-13-A — Features • Comfort-R™ enhanced mode (cooling)................................................ ✔ ✔ — — —— • AccuLink™ system............................................................................... ✔ — — — —— • Can be connected in communicating or 24V non communicating modes. (also see communicating section).................... ✔ — — — —— • User interface for system configuration Easy to use navigation buttons and plain text for clear description of features............................................................................ ✔ — — — —— • Adjustable heating fan off timing............................................................ ✔ ✔ ✔ ✔ ✔ ✔ • Alternate bottom/left/right return air (upflow models only) ..................... ✔ ✔ ✔ ✔ ✔ ✔ • Attractive color accents.......................................................................... ✔ ✔ ✔ ✔ ✔ — • Blower door safety switch....................................................................... ✔ ✔ ✔ ✔ ✔ ✔ • Bottom Panel (upflow models only)......................................................... ✔ ✔ ✔ ✔ ✔ — • Cleanable/reusable high velocity filters.................................................. ✔ ✔ — ✔ —— • Common vent capability......................................................................... ✔ ✔ ✔ ✔ ✔ ✔ • Complete front service access............................................................... ✔ ✔ ✔ ✔ ✔ ✔ • Direct drive, multi-speed (PSC) blower motor........................................ — — ✔ ✔ ✔ ✔ • Direct drive, multi-speed ECM blower motor (high efficiency)*................ — — — ✔ —— • Direct drive, variable speed ECM blower motor**.................................. ✔ ✔ — — — — • Gasketed blower door............................................................................ ✔ ✔ ✔ ✔ ✔ — • Heavy gauge reinforced wrap-around steel cabinet.............................. ✔ ✔ ✔ ✔ ✔ ✔ • Horizontal left/right without conversion required.................................... ✔ ✔ ✔ ✔ ✔ ✔ • Humidifier/EAC hook-up capability ....................................................... ✔ ✔ ✔ ✔ ✔ — • Inner blower door panel (downflow models only)................................... ✔ ✔ ✔ ✔ ✔ ✔ • Insulated blower compartment 4 sides (upflow models only) ................ ✔ ✔ ✔ ✔ ✔ — • Integrated solid state control w/self diagnostics..................................... ✔ ✔ ✔ ✔ ✔ ✔ • Left/right gas connection........................................................................ ✔ ✔ ✔ ✔ ✔ ✔ • Manual reset flame roll out switches...................................................... ✔ ✔ ✔ ✔ ✔ ✔ • Masonry Chimney Venting w/BAYVENT800B....................................... ✔ ✔ ✔ ✔ ✔ ✔ • Multi-port in shot burners....................................................................... ✔ ✔ ✔ ✔ ✔ ✔ • Painted cabinet single color................................................................... — — — —— ✔ • Perfect fit door latches (upflow models only) .......................................... ✔ ✔ ✔ ✔ ✔ — • Right or left hand side knock out for venting (downflow models only).......................................................................... ✔ ✔ ✔ ✔ ✔ ✔ • Selectable cooling fan off delay eliminates need for time delay relay BAY24X045............................................................. — ✔ ✔ ✔ ✔ ✔ • Service diagnostic capabilities............................................................... ✔ ✔ ✔ ✔ ✔ — • Service diagnostics with faults reported at the user interface.................. ✔ — — — —— • Side return starter tabs (upflow models only)......................................... ✔ ✔ ✔ ✔ ✔ ✔ • Silicon Nitride hot surface igniter with adaptive heat up....................... ✔ ✔ ✔ ✔ ✔ ✔ • Single door filter access ........................................................................ ✔ ✔ ✔ ✔ ✔ — • Single wire twinning .............................................................................. — — ✔ ✔ ✔ — • Slide out blower assembly..................................................................... ✔ ✔ ✔ ✔ ✔ ✔ • 3-way vent option on downflow models (top,right or left) (downflow models only).......................................................................... — ✔ ✔ ✔ ✔ ✔ • 20 gauge aluminized steel heat exchanger........................................... ✔ ✔ ✔ ✔ ✔ ✔ • 24 volt secondary fuse........................................................................... — ✔ ✔ ✔ ✔ ✔ • Two heating blower speeds................................................................... ✔ ✔ ✔ — —— • Two speed venter motor........................................................................ ✔ ✔ ✔ — —— • Two tone color........................................................................................ ✔ ✔ ✔ ✔ ✔ — • Two-stage gas valve............................................................................... ✔ ✔ ✔ — —— • Registered limited lifetime heat exchanger warranty and 10-year on all other functional parts (Residential Use)2............................................................................. ✔ ✔ — — —— • Registered 20-year heat exchanger limited warranty and 10-year on all other functional parts (Residential Use)............................... — — ✔ ✔ ✔ ✔ • Optional extended warranties available............................................ ✔ ✔ ✔ ✔ ✔ ✔ 1 Freedom 80 furnace with integrated AccuClean™ technology is upflow or upflow/horizontal application only. 2Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. 3Variable Speed Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. *Constant torque ECM (electronically commutated motor). **Constant airflow ECM (electronically commutated motor). For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-13 Effective 7/1/12 14-1011-28 Platinum SV, Gold SV, Gold SM, Silver XI, Silver SI+, and Silver SI Convertible Gas Furnaces AUD2-ACV/ADD2-ACV AUD2-9V/ 2 Stage ADD2-9V 2-Stg. Table FUR-14-A — Optional Accessories Variable Speed Variable Speed Model Number Description Shipping Weight BAYBASE205...........Downflow subbase for downflow models only.................. 8................................................... ✔ ✔ BAYFLTR200............Side Filter Rack (External)............................................... 5................................................... ✔ ✔ BAYFLTR203............Filter kit horiz conversion for 17.5" cabinet...................... 3................................................... ✔ ✔ BAYFLTR204............Filter kit horiz conversion for 21" cabinet......................... 3................................................... ✔ ✔ BAYFLTR205............Filter kit horiz conversion or 24.5" cabinet....................... 3................................................... ✔ ✔ BAYFLTR206............Filter Access Door Kit....................................................... 2................................................... ✔ ✔ BAYFLTR3211 .......Cleanable filter for 21" cabinet upflow only...................... 2................................................... ✔ ✔ BAYFLTR3241 .......Cleanable filter for 24.5" cabinet upflow only................... 2................................................... ✔ ✔ BAYLPKT210B.........Propane conversion kit..................................................... 1................................................... ✔ ✔ BAYLPSS210B.........LP Kit with Stainless Steel Burners.................................. 1................................................... ✔ ✔ BAYRACK960A2 ...Filter Rack Kit for upflow models only (internal)............... 5................................................... ✔ ✔ BAYVENT800B .......Masonry chimney vent kit................................................. 2................................................... ✔ ✔ 1Contains one (1) high velocity filter. 2Internal filter rack for side or bottom return air. Includes 17 x 25" cleanable filter for use in side return applications. Bottom return applications require different sizes of filters which are not included. Airflow requirements over 1800 CFM require filters on both sides or a side and bottom or bottom only. 3Freedom 80 furnace with integrated AccuClean™ technology is upflow or upflow/horizontal application only. Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. AUD2/ADD2 AUD1-H/ADD1-H AUD1/ADD1AUE1/ADE1 2 Stage 1 Stage 1 Stage 1 Stage High Efficiency Table FUR-14-B — Optional Accessories Model Number Description Shipping Weight BAYBASE205...........Downflow subbase for downflow models only.......................8......................... BAYFLTR200............Side Filter Rack (External)....................................................5......................... BAYFLTR203............Filter kit horiz conversion for 17.5" cabinet...........................3......................... BAYFLTR204............Filter kit horiz conversion for 21" cabinet..............................3......................... BAYFLTR205............Filter kit horiz conversion or 24.5" cabinet............................3......................... BAYFLTR206............Filter Access Door Kit............................................................2......................... BAYFLTR3171 .......Cleanable filter for 14.5" and 17.5" cabinet upflow only ...........2......................... BAYFLTR3211 .......Cleanable filter for 21" cabinet upflow only...........................2......................... BAYFLTR3241 .......Cleanable filter for 24.5" cabinet upflow only........................2......................... BAYLPKT210B.........Propane conversion kit..........................................................1......................... BAYLPSS210B.........LP Kit with Stainless Steel Burners.......................................1......................... BAYRACK960A2 ...Filter Rack Kit for upflow models only (internal)....................5......................... ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔— ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ BAYVENT800B .......Masonry chimney vent kit......................................................2......................... ✔ ✔ ✔ ✔ 1Contains one (1) high velocity filter. 2Internal filter rack for side or bottom return air. Includes 17 x 25" cleanable filter for use in side return applications. Bottom return applications require different sizes of filters which are not included. Airflow requirements over 1800 CFM require filters on both sides or a side and bottom or bottom only. Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. Special Use Furnace Accessories Table FUR-14-C — High Altitude Pressure Switch 80% Model Number Description Used With BAYHALT248 BAYHALT249 Bonnet TAYPLUS103A Switch 1 Switch 1 Switch AUD1,ADD1,AUE1,ADE1 AUD-R-K,ADD-R-F,AUD2,ADD2 Shipping Weight 2 2 Table FUR-14-D — Dual Fuel Heat Pump Control Kit12 Case Height Used With TAYPLUS103A.............. Heat Pump Control Kit.............Gas, LP., Oil and Electric Furnaces TAYSTAT250B............... Outdoor Thermostat.................TAYPLUS103A for Restricted Mode Model Number 1 Factory wired for non-restricted mode, can be wired for restricted mode. 2 Applicable for all furnaces with 35 VA or larger low voltage transformer (separate high voltage power not required). For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-14 Effective 7/1/12 14-1011-28 Variable Speed High Efficiency Oil Furnaces •Up to 85% Annual Fuel Utilization Efficiency TDF -Downflow/Horizontal TLF -Lowboy Front Flue (TLR not shown) (AFUE) • 13 gauge hot rolled steel wrap around heat exchanger for durability • Beckett Flame Retention Burner operates cleanly and quietly • Burner features include primary control with interrupted ignition for reliability, pre-purge and clean cutoff solenoid valve for smooth ignition • Burner and controls factory wired • Dual clean out ports for quick access and easy cleaning • Insulated blower compartment • Variable speed blower motor • Slide out blower assembly for quick cleaning and service accessibility • Filter rack with cleanable filter (Highboy & Lowboy Models only) • Preformed ceramic fiber combustion chamber for higher efficiencies and more complete combustion • 40 VA control transformer for add on cooling • Heavy gauge, powder painted steel cabinet • Recessed door handles for easy removal of Highboy & lowboy Furnace doors • Lowboy models available with front or rear flue option • Highboy models with top or right side venting • Downflow/Horizontal model field convertible from Downflow to right or left horizontal • 6" Left and Right side fresh air knockouts – (Highboy and Lowboy Models only) • Barometric draft regulator included • Registered limited lifetime heat exchanger warranty and 10-year on all other functional parts (Residential Use)3 • Optional extended warranties available THV -Highboy Vertical Table FUR-15-A — Specifications: Model Number THV1M087A9V3SA THV1M087A9V5SA TLF1M087A9V3SA TLF1M087A9V5SA TLR1M087A9V3SA TLR1M087A9V5SA TDF1M087A9V3SA TDF1M087A9V5SA Airflow In Tons (Nom.) 3 5 3 5 3 5 3 5 Nominal Uncrated Cap-BTUH ICS Flue Dimensions(In.) Shipping *Htg Output AFUE Size H W D Weight 87,000 82.9 6" 58 22.2531 260 87,000 82.6 6" 58 22.2531 260 87,000 82.9 6" 41.522.25 47 300 87,000 82.7 6" 41.522.25 47 300 87,000 85.0** 6" 41.522.25 47 300 87,000 82.4 6" 41.522.25 47 300 87,000 84.8 6" 22.2561.25 22.25 280 87,000 82.6 6" 22.2561.25 22.25 280 * Other input/output capacities are available by changing the burner nozzle. See installer's guide for details. ** Energy Star. Table FUR-15-B — Accessories: Shipping Model Description Used With Weight BAYSUB10ABASEA Downflow Subbase TDF1M087A9V3, 9V5SAA 22 BAYTRM10AVENTA Top Panel & Trim Ring THV1M087A9V3, 9V5SAA 1 Table FUR-15-C — Dual Fuel Heat Pump Control Kit12 Case Height Used With TAYPLUS103A.............. Heat Pump Control Kit.............Gas, LP., Oil and Electric Furnaces TAYSTAT250B............... Outdoor Thermostat.................TAYPLUS103A for Restricted Mode THT1248....................... Bonnet Switch..........................Oil Furnaces Only (Order Separately) Model Number 1Factory wired for non-restricted mode, can be wired for restricted mode. 2Applicable for all furnaces with 35 VA or larger low voltage transformer (separate high voltage power not required). 3 Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-15 Effective 7/1/12 14-1011-28 High Efficiency Oil Furnaces • Up to 85% Annual Fuel Utilization • • • TDF -Downflow/Horizontal • • • • • TLF -Lowboy Front Flue • (TLR not shown) • Efficiency (AFUE) 13 gauge hot rolled steel wrap around heat exchanger for durability Beckett Flame Retention Burner operates cleanly and quietly Burner features include primary control with interrupted ignition for reliability, pre-purge and clean cutoff solenoid valve for smooth ignition Burner and controls factory wired Dual clean out ports for quick access and easy cleaning Direct drive, permanently lubricated, 4 speed blower motor Insulated blower compartment Slide out blower assembly for quick cleaning and service accessibility Filter rack with washable filter (Highboy & Lowboy Models only) Preformed ceramic fiber combustion chamber for higher efficiencies and more complete combustion • 40 VA control transformer for add on cooling • Heavy gauge, powder painted steel cabinet • Recessed door handles for easy removal of Highboy & lowboy Furnace doors • Lowboy models available with front or rear flue option • Highboy models with top or right side venting • Downflow/Horizontal model field convertible from Downflow to right or left horizontal • 6" Left and Right side fresh air knockouts – (Highboy and Lowboy Models only) • Barometric draft regulator included • Registered limited lifetime heat exchanger warranty and 10-year on all other functional parts (Residential Use)3 • Optional extended warranties available THV -Highboy Vertical Table FUR-16-A — Specifications: Model Number THV1M087A936SA THV1M087A948SA TLF1M087A936SA TLF1M087A948SA TLR1M087A936SA TLR1M087A948SA TDF1M087A936SA TDF1M087A948SA Airflow In Tons (Nom.) 3 4 3 4 3 4 3 4 Nominal Uncrated Cap-BTUH ICS Flue Dimensions(In.) Shipping *Htg Output AFUE Size H W D Weight 87,000 82.9 6" 58 22.2531 260 87,000 82.6 6" 58 22.2531 260 87,000 82.9 6" 41.5 22.2547 300 87,000 82.7 6" 41.5 22.2547 300 87,000 85.0**6" 41.5 22.2547 300 87,000 82.4 6" 41.5 22.2547 300 87,000 84.8 6" 22.2561.2522.25 280 87,000 82.6 6" 22.2561.2522.25 280 * Other input/output capacities are available by changing the burner nozzle. See installer's guide for details. ** Energy Star. Table FUR-16-B — Accessories: Shipping Model Description Used With Weight BAYSUB10ABASEA Downflow Subbase TDF1M087A936, 948SAA 22 BAYTRM10AVENTA Top Panel & Trim Ring THV1M087A936, 948SAA 1 Table FUR-16-C — Dual Fuel Heat Pump Control Kit12 Case Height Used With TAYPLUS103A.............. Heat Pump Control Kit.............Gas, LP., Oil and Electric Furnaces TAYSTAT250B............... Outdoor Thermostat.................TAYPLUS103A for Restricted Mode THT1248....................... Bonnet Switch..........................Oil Furnaces Only (Order Separately) Model Number 1Factory wired for non-restricted mode, can be wired for restricted mode. 2Applicable for all furnaces with 35 VA or larger low voltage transformer (separate high voltage power not required). 3 Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-16 Effective 7/1/12 14-1011-28 AccuClean™ Whole Home Air Cleaner AccuClean™ Whole Home Air Cleaner: • AccuClean™ removes up to 99.98% of allergens from the filtered air • Removes particles down to .1 micron in size • Outperforms HEPA, and up to 100 times more effective than a standard 1" filter • Constructed of heavy 18 gage metal to protect the filter and internal electronics • Power door provides easy access to internal components and features a filter status display as well as safety interlocks that automatically shut down the power when the door is opened for maintenance or cleaning • Designed for flush fit on both sides and rear of equipment cabinet • No transitions required on AccuClean™ applications • Gaskets included with the air cleaner • AccuLink™ communicating or 24 volt capability • Base Limited Warranty 5-years • Registered Limited Warranty 10-years Table IAQ-1-A – Air Handler – 24 Volt AccuClean™ Whole Home Air Cleaner Model Airflow AccuClean™ Number Range Air Handler Width AFD175CLAH000D300-1200 AFD215CLAH000D300-1200 AFD235CLAH000D350-1600 AFD260CLAH000D 400-2000 171/2 inch 211/2 inch 231/2 inch 26 inch Uncrated Dimensions(in.) H x W x D Shipping Weight 71/2 x 171/2 x 21 71/2 x 211/2 x 21 71/2 x 231/2 x 21 71/2 x 26 x 21 37 42 44 46 Table IAQ-1-B – Upflow / Side Return Furnace – 24 Volt AccuClean™ Whole Home Model Airflow AccuClean™ Number Range Furnace Width AFD145CLFR000D300-1200 AFD175CLFR000D300-1600 AFD210CLFR000D 300-2000 AFD245CLFR000D400-2000 Uncrated Dimensions(in.) H x W x D Shipping Weight 141/2 inch171/2 x 141/2 x 27 171/2 inch171/2 x 171/2 x 27 21 inch271/2 x 21 x 27 241/2 inch271/2 x 241/2 x 27 39 43 47 49 Table IAQ-1-C – Downflow Furnace – 24 Volt AccuClean™ Whole Home Model Airflow AccuClean™ Number Range Furnace Width AFD14DCLFR000D300-1200 AFD17DCLFR000D300-1600 AFD21DCLFR000D 300-2000 AFD24DCLFR000D400-2000 141/2 inch 171/2 inch 21 inch 241/2 inch Uncrated Dimensions(in.) H x W x D Shipping Weight 71/2 x 141/2 x 21 71/2 x 171/2 x 21 71/2 x 21 x 21 71/2 x 241/2 x 21 33 37 41 45 Table IAQ-1-D — Accessories – AccuClean™ Whole Home Model Number Description Used With BAYTRANS12024 120 to 24 Volt Transformer All AFD Air Cleaners Shipping Weight 6 1 Side return no transition required. 2 Side return transition required. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. IAQ-1 Effective 7/1/12 14-1011-28 Perfect Fit™ Media Filters • Four sizes to flush fit bottom of American Standard furnaces • TFP175, TFM175 (17½") bottom return model can be used for a Perfect Fit™ side return on all furnace models • Air Cleaners designed for flush fit on both sides and rear of equipment cabinet • All service and access is from the front of the air cleaner • Air-Tite™ Door construction eliminates air leaks, improves air quality and keeps operating costs low • Gaskets included with the air cleaner Table IAQ-2-A– Air Handler Perfect Fit™ High Efficiency Air Cleaner With Five (5) Inch Expandable Media Filter Model Airflow Perfect Fit™ Number Range Air Handler Width TFM215B0AH0 300-1400 211/2 inch TFM235B0AH0 300-1700231/2 inch TFM260B0AH0 400-2100 26 inch Uncrated Dimensions(in.) H x W x D Shipping Weight Return Air Opening3 71/2 x 211/2 x 21 71/2 x 231/2 x 21 71/2 x 26 x 21 22 24 25 187/8 x187/8 207/8 x187/8 237/8 x187/8 Table IAQ-2-B – Furnace Perfect Fit™ High Efficiency Air Cleaner With Five (5) Inch Expandable Media Filter Model Airflow Perfect Fit™ Number Range Furnace Width Uncrated Dimensions(in.) H x W x D TFM145B0FR0 300-1200141/2 inch171/2 x141/2 x 27 TFM175B0FR0 300-1500171/2 inch171/2 x 171/2 x 27 TFM210B0FR0 300-2000 21 inch271/2 x 21 x 27 TFM245B0FR0 400-2000241/2 inch271/2 x 241/2 x 27 Shipping Weight Return Air Opening3 18 21 24 27 117/8 x2413/16 147/8 x2413/16 183/8 x2413/16 217/8 x2413/16 Table IAQ-2-C – Downflow Furnace Perfect Fit™ High Efficiency Air Cleaner With Five (5) Inch Expandable Media Filter Model Airflow Perfect Fit™ Number Range Furnace Width TFM14DA0FR0300-1200141/2 inch TFM17DA0FR0300-1500171/2 inch TFM21DA0FR0 300-2000 21 inch TFM24DA0FR0400-2000241/2 inch Uncrated Dimensions(in.) H x W x D Shipping Weight Return Air Opening3 71/2 x141/2 x 21 71/2 x 171/2 x 21 71/2 x 21 x 21 71/2 x 241/2 x 21 17 19 22 24 117/8 x187/8 147/8 x187/8 183/8x187/8 217/8 x187/8 Table IAQ-2-D – Air Handler Perfect Fit™ Medium Efficiency Air Cleaner With One (1) Inch Pleated Filter Model Airflow Perfect Fit™ Number Range Air Handler Width TFP215A0AH1 300-1200211/2 inch TFP235A0AH1 300-1500231/2 inch TFP260A0AH1 400-1800 26 inch Uncrated Dimensions(in.) H x W x D Shipping Weight Return Air Opening3 71/2 x 211/2 x 21 20 187/8 x187/8 71/2 x 231/2 x 21 22 207/8 x187/8 1 7 /2 x 26 x 21 24 237/8 x187/8 Table IAQ-2-E – Furnace Perfect Fit™ Medium Efficiency Air Cleaner With One (1) Inch Pleated Filter Model Airflow Perfect Fit™ Number Range Furnace Width TFP145A0FR1 TFP175A0FR1 TFP210A0FR1 TFP245A0FR1 Uncrated Dimensions(in.) H x W x D 300-1200141/2 inch171/2 x141/2 x 27 300-1500171/2 inch171/2 x 171/2 x 27 400-1800 21 inch271/2 x 21 x 27 400-2000241/2 inch271/2 x 241/2 x 27 Shipping Weight Return Air Opening3 17 19 22 25 117/8 x2413/16 147/8 x2413/16 183/8 x2413/16 217/8 x2413/16 1 Side return no transition required. 2 Side return transition required. 3 Actual opening does not include flange. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. IAQ-2 Effective 7/1/12 14-1011-28 Perfect Fit™ Filter Accessories Table IAQ-3-A — Furnace Enclosure Filters Model EnclosureShipping Number Description Qty Used with Weight BAYFTFR14P4 BAYFTFR17P4 BAYFTFR21P4 BAYFTFR24P4 BAYFTFR14M2 BAYFTFR17M2 BAYFTFR21M2 BAYFTFR24M2 BAYFTFREXM2 1" Pleated Filter 1" Pleated Filter 1" Pleated Filter 1" Pleated Filter 5" Media Filter 5" Media Filter 5" Media Filter 5" Media Filter Expandable 5" Cartridge Media Filter 4 / Box 4 / Box 4 / Box 4 / Box 2 / Box 2 / Box 2 / Box 2 / Box 2 / Box 14 1/23 17 1/23 21 3 24 1/23 14 1/25 17 1/25 21 5 24 1/26 14 1/2-24 1/25 Table IAQ-3-B — Air Handler Enclosure Filters Model EnclosureShipping Number Description Qty Used with Weight BAYFTAH21P4 BAYFTAH23P4 BAYFTAH26P4 BAYFTAH21M2 BAYFTAH23M2 BAYFTAH26M2 BAYFTAHEXM2 1" Pleated Filter 1" Pleated Filter 1" Pleated Filter 5" Media Filter 5" Media Filter 5" Media Filter Expandable 5" Cartridge Media Filter 4 / Box 4 / Box 4 / Box 2 / Box 2 / Box 2 / Box 2 / Box 21 1/23 23 1/23 26 3 21 1/25 23 1/25 26 6 21 1/2-265 Table IAQ-3-C — Downflow Cartridge Media Model EnclosureShipping Number Description Qty Used with Weight BAYFTDN14M2 BAYFTDN17M2 BAYFTDN21M2 BAYFTDN24M2 5" Downflow Media Filter 5" Downflow Media Filter 5" Downflow Media Filter 5" Downflow Media Filter 2/ Box 2/ Box 2/ Box 2/ Box 14 D 17 D 21 D 24 D 5 5 5 5 Table IAQ-3-D — Furnace Frames Model EnclosureShipping Number Description Qty Used with Weight BAYFRAME1451 BAYFRAME1751 BAYFRAME2101 BAYFRAME2451 Expandable Media Filter Expandable Media Filter Expandable Media Filter Expandable Media Filter 1/ Box 1/ Box 1/ Box 1/ Box 14 1/2 17 1/2 21 24 1/2 5 5 5 5 Table IAQ-3-E — Air Handler Frames Model EnclosureShipping Number Description Qty Used with Weight BAYFRAME2151 BAYFRAME2351 BAYFRAME2601 Expandable Media Frame Expandable Media Frame Expandable Media Frame 1/ Box 1/ Box 1/ Box 21 23 1/2 26 5 5 5 1 Includes one filter. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. IAQ-3 Effective 7/1/12 14-1011-28 Perfect Fit™ Table IAQ-4-A — Air Handler Filters AIR HANDLER MODEL NUMBER 1" Pleated Filter 5" Media Filter AccuClean™ A B TFP215A0AH0TFM215A0AH0 AFD215CLAH000D 211/219 TFP235A0AH0TFM235A0AH0 AFD235CLAH000D 231/221 TFP260A0AH0TFM260A0AH0 AFD260CLAH000D 26 231/2 OUTLINE DRAWING AIR HANDLER MODELS OUTLINE DRAWING AIR HANDLER MODELS 2-13/16" CABINET DEPTH ONLY 21" CABINET DEPTH21" ONLY ADD DOOR DEPTH FOR TOTAL ADD DOOR DEPTH FOR TOTAL 2-13/16" 1-7/16 1-7/16 Side View 7-7/16 21 21 3-5/16 3-5/16 18-7/8 18-7/8 B AccuClean™ AccuClean™ 1" PLEATED 5" MEDIA ELECTRONIC 1" PLEATED 5" MEDIA For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. 7-7/16 A Top of Cabinet B ELECTRONIC IAQ-4 Effective 7/1/12 14-1011-28 A Perfect Fit 27" CABINET DEPTH ONLY OUTLINE DRAWING UPFLOW FURNACE ™ MODELS ADD DOOR DEPTH FOR TOTAL Table IAQ-5-A — Upflow Furnace Filters 1-7/16 2-13/16" FURNACE MODEL NUMBER 7-7/16 1" Pleated Filter 5" Media Filter AccuClean™ A B 3-5/16 TFP145A0FR0 TFM145A0FR0 AFD145CLFR000D141/212 TFP175A0FR0 TFM175A0FR0 AFD175CLFR000D171/215 27 1/8 TFP210A0FR0 TFM210A0FR0 AFD210CLFR000D 21181/2 TFP245A0FR0 TFM245A0FR0 AFD245CLFR000D241/222 24-13/16 Table IAQ-5-B — Downflow Furnace Filters FURNACE MODEL NUMBER B A 5" Media Filter AccuClean™ A B TFM14DA0FR0AFD14DCLFR000D 141/2117/8 TFM17DA0FR0AFD17DCLFR000D 171/2147/8 TFM21DA0FR0AFD21DCLFR000D 21 183/8 TFM24DA0FR0AFD24DCLFR000D 241/2217/8 1" PLEATED 5" MEDIA AccuClean™ 1/8 ELECTRONIC OUTLINE DRAWING OUTLINE DRAWING DOWNFLOW FURNACE MODELS OUTLINE DRAWING UPFLOW FURNACE MODELS UPFLOW FURNACE MODELS AWING DOWNFLOW FURNACE MODELS 27" CABINET DEPTH ONLY ADD DOOR DEPTH FOR TOTAL 21" CABINET DEPTH ONLY ADD DOOR DEPTH FOR TOTAL 2-13/16" 1-7/16 Side View 7-7/16 Side View 7-7/16 3-5/16 27 1/8 21 24-13/16 18-7/8 B B CleanEffects™ 1" PLEATED 5" MEDIA Top of Cabinet A Top of Cabinet A 1/8 ELECTRONIC D For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. IAQ-5 Effective 7/1/12 14-1011-28 Humidifiers Fan Powered and Bypass AHUMD500A • Flow Through Fan Powered Humidifier • High Performance Humidifier Delivers up to 18 Gallons per Day • Automatic Humidifier Control with O.D. Sensor for up to 50% more Humidity • Front Cover Access for easy replacement of humidifier pad • Aluminum Humidifier Pad Treated with Ceramic Coating for Enhanced Pad Performance • Reliable Brass Solenoid Valve w/Stainless Steel Valve Seat • UV Resistant Cabinet and Scale Control Insert • Saddle Valve • Polyslate Gray Housing matches Furnace Cabinet Color • Decorative nameplate • 120V Power Line Cord AHUMD500A AHUMD200, 300A AHUMD200A, 300A • AHUMD300A Bypass delivers up to 17 Gallons per day • AHUMD200A delivers up to 12 Gallons per day • AHUMD300A Automatic Humidifier Control and O.D. Sensor for up to 50% more Humidity • AHUMD200A Manual Humidifier Control • UV Resistant Cabinet and Scale Control Insert • Front Cover Access for easy replacement of humidifier pad • Aluminum Humidifier Pad Treated with Ceramic Coating for Enhanced Pad Performance • Reliable Brass Solenoid Valve w/Stainless Steel Valve Seat • Field Convertible Duct Connection, Left or Right Side • Built in Summer / Winter Damper • Saddle Valve • Polyslate Gray Housing matches Furnace Cabinet Color • Decorative nameplate • 110V Primary/24V Secondary, 10VA transformer Table IAQ-6-A — Specifications: Humidifier with Humidistat Model Number Description Used With Mfg.Shipping Plant Weight AHUMD500APA00B14 AHUMD300ABA00B2 AHUMD200ABM00B3 TY TY TY Fan Powered Humidifer Large Bypass Humidifier Small Bypass Humidifier All Furnace Models All Furnace Models All Furnace Models 20 15 14 1Includes Automatic Humidifier Control (Duct Mount Only). 2Includes Automatic Humidifier Control (Duct Mount Only) and 120/24V transformer. 3Includes Manual Humidifier Control and 120/24V transformer. 4Not applicable for horizontal installations. Table IAQ-6-B — Accessories Model Number Description Used With Mfg.Shipping Plant Weight BAYPAD02A1310A BAYPAD01A1010A ACONTH01AAUTOA BAYRLY10ASENSA BAYPLT01AMHCOA TY TY TY TY TY Large Humidifier Pad 13”x10” Small Humidifier Pad 9-7/8”x9-5/8” Automatic Humidifier Control Current Sensing Relay Adapter Plate (Duct Mount) For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AHUMD500,300A AHUMD200A AHUMD200A All Manual Humidifier Control IAQ-6 1 1 1 1 1 Effective 7/1/12 14-1011-28 Humidifiers Fan Powered and Bypass AHUMD500APA00B FAN POWERED HUMIDIFIER 10.34 15.91 16.13 18.00 AHUMD300ABA00B LARGE BYPASS HUMIDIFIER 15.38 14.00 10.25 15.15 15.75 AHUMD200ABM00B SMALL BYPASS HUMIDIFIER 15.63 14.00 10.25 12.25 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. IAQ-7 13.00 Effective 7/1/12 14-1011-28 Humidifiers Fan Powered and Bypass mANUAL HUMIDIFIER CONTROL (SHIP WITH AHUMD200ABM00B) ACONTH01aAUTOA AUTOMATIC HUMIDIFIER CONTROL suggested bypass humidifier locations FLUE RETURN AIR SUPPLY AIR RETURN AIR HUMIDIFIER OPTIONAL FLUE NOT ALL MODELS COOLING COIL UPFLOW FURNACE OPTION “A” REAR OF FURNACE OR REAR MOUNT SUPPLY AIR SUPPLY AIR RETURN AIR RETURN AIR FLUE COOLING COIL HUMIDIFIER COOLING COIL HUMIDIFIER SUPPLY AIR HORIZONTAL FURNACE UPFLOW FURNACE OPTION “B” FRONT OF FURNACE OR FRONT MOUNT For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. IAQ-8 Effective 7/1/12 14-1011-28 Energy Recovery Ventilator (ERV) • American Standard ERV technology for all seasons and climates • Static plate energy transfer core for efficient transfer of heat and moisture • Passive defrost - condensate drain not required • Balancing dampers not required • Multi position mounting • Percent Timer (PT) control included with ERV for simple, automatic operation • Optional Push Button (PB) control connects to PT control • Cam action door latches for quick service access • Heavy gauge, powder painted steel cabinet • Permanently lubricated motor bearings (ball bearings) • 6" and 8" double collar duct connections for AERVR100 and 200 • 8" round compatible duct connection for AERVR300 • Closed cell foam gasketing for insulation integrity • 1" duct board insulation with cleanable foil face • May be installed in conditioned and unconditioned spaces • Cabinet / Door color: American Standard Polyslate Gray / Tarpaulin Gray • Based Limited Warranty 5-years • Registered Limited Warranty 10-years • Optional extended warranty Table IAQ-9-A — Specifications: ERV Model Number Nominal Airflow Power (CFM) Supply AERVR100A9P00A1130 AERVR200A9P00A1 200 AERVR300A9P00A1 300 Uncrated Dimensions (In.) H x W x D Shipping Weight 120/1/6020 /8 x 28 /4 x 13 65 120/1/60201/8 x 283/4 x 237/885 120/1/60201/8 x 283/4 x 237/895 1 3 1Percent Timer Control included with the ERV. Table IAQ-9-B — Specifications: ERV Model Number Apparent Sensible Effectiveness(32°F) Sensible Recovery Effectiveness(32°F) Latent Recovery (32°F) Total Recovery (95°F) AERVR100A9P00A AERVR200A9P00A AERVR300A9P00A 80% @ 124 cfm 85% @ 181 cfm 78% @ 295 cfm 72% @ 124 cfm 78% @ 181 cfm 70% @ 295 cfm 55% @ 124 cfm 62% @ 181 cfm 51% @ 295 cfm 46% @ 126 cfm 52% @ 180 cfm 43% @ 295 cfm Table IAQ-9-C — Optional Accessories Model Number Description Used With ACONTV10APBC0A BAYFLT10A1010A BAYFLT20A1020A BAYWHT10AVENTA2 BAYBRN10AVENTA2 BAYGLV10AVENTA2 Point of Use Push Button Control Filters - 2 per pack Filters - 2 per pack 6 inch White Vinyl Ventilation Hood 6 inch Brown Vinyl Ventilation Hood 8 inch Galvenized Ventilation Hood ERV models 100, 200, 300 ERV models 100 ERV models 200, 300 ERV models 100, 200 ERV models 100, 200 ERV models 300 Shipping Weight 1 1 1 1 1 2 2 Qty 1. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. IAQ-9 Effective 7/1/12 14-1011-28 AccuLink™ Platinum ZV Control Schlage LiNK™ is now NEXIA™ Home Intelligence Features: AZONE950AC52ZA • Controls Communicating or conventional 24V HVAC systems (5 heat/2 cool/Dual Fuel) with 24V Relay Panel Accessory • 7" High Definition Color Lcd Display • Compatible with AccuLink™ Zoning Systems - software version 2.0 or later required • Optional faceplate colors (black, white, graphite) • System Modes - Heat/Cool/Auto • Fan Modes - On/Auto/Circulate • Easy to use Touch Screen Interface • 7 Day Programmable - (manual or guided scheduling options) • 1-Touch Pre-Sets for Home, Away, Sleep Settings • Customizable Home Screen (Color, Information, Layout) • 5 Day Weather Forecast, Local Radar Image & Weather Alerts (via Wireless Home Network) • Weekly & Monthly System Run Time Monitor • Allergy Clean & Quick Clean Indoor Air Cycles • Built in Dual Fuel Economic Calculator. • Digital Photo Album with Slide Show Screen Saver Option • Embedded Diagnostics - (Alerts have time/date stamp with on screen probable causes) • Heating Humidification Control -Relative Humidity Control -Dew Point Control • Cooling Dehumidification Control • Ventilation Control • Whole-house Dehumidifier Control • Smart Continuous Fan (disables Cont. Fan if Rh is above setpoint) • Adjustable Continuous Fan Airflow Settings (35 to 100%) For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-1 • Service Reminders - Filters, Eac, Humidifier, Hvac System, Uv Lights • Upgradeable Firmware via internet (SD Card required) • Remote Access Option via Internet & Cell Phone (Nexia™ Home Intelligence six month trial subscription service included—software version 2.0 or later required) • Keypad lock - Pin Code Option Security Options • Dealer and System Information Screens • Remote Indoor Temperature Sensor (Optional Wired) • Outdoor Temperature Sensor Option for 24 Volt systems • Fahrenheit or Celsius Indoor Display Options • 802.11 B/G - WLan (wireless local area network) for weather feed Dimensions: • 7.3" width X 4.3" height X 1.2" depth Storage Temperature: • -40°F to 175°F, 5% to 95% Rh non-condensing Operating Temperature: • 25°F to 126°F, 5% to 90% Rh non-condensing Optional front bezels for Platinum ZV Control: Graphite - AZGRA950ABEZEL White - AZWHT950ABEZEL Black - AZBLK950ABEZEL Effective 7/1/12 14-1011-28 Wired Sensor with Display AZONE940AC52ZA • Compatible with AccuLink™ Zoning Systems • 3-Wire Communicating Zone Sensor • 4.5" backlit touch screen black and white display • Optional faceplate colors (silver/black, black, white, graphite) • Zone Mode - Heat/Cool/Auto • Fan Mode - Auto/On • Synchronizes with AZONE950 Real Time Clock • Weekly Comfort Settings scheduled from AZONE950 • Zone Schedule Overide -Permanent Hold -Temporary Override • 1-Touch Pre-Sets For Home, Away, Sleep Settings • 24V power • Displays Zone Temperature & Relative Humidity • Displays Outdoor Temperature & Outdoor Relative Humidity (if available on AZONE950) • Clean Screen Function • Keypad lock- enabled from AZONE950 • Fahrenheit or Celsius - enabled from AZONE950 (system level setting) Dimensions: • 5.5" width x 3.4" height x 1.1" depth Storage Temperature: • -40°F to 170°F, 0% - 95% RH Operating Temperature: • 32°F - 120°F, 5% - 90% RH non-condensing Optional front bezels for AZONE940 Control: • AZSBK940ABEZEL - Silver/Black • AZGRA940ABEZEL - Graphite • AZWHT940ABEZEL - White • AZBLK940ABEZEL - Black Coming in 2nd Half 2012 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-2 Effective 7/1/12 14-1011-28 Conventional 24 Volt HVAC System Interface Relay Panel for AccuLink™ Platinum ZV Control BAY24VRPAC52DA — Without AUX Contact Control Relay Panel BAY24VRPAC52DA • 5 Heat (Gas, Oil, Electric)/2 Cool/Heat Pump/Dual Fuel • Optional remote indoor temperature connection point • Optional outdoor temperature connection point • LED stage indicators • Removable low voltage terminal blocks for easy service and replacement • Humidifier Control Dimensions: • 8.0" width x 9.3" height x 1.9" depth Storage Temperature: • -40° to 175°F, 5% - 95% RH non-condensing Operating Temperature: • -40° to 150°F, 5% - 95% RH non-condensing Note: For applications requiring AUX Contact Control, please use "B" model below. BAY24VRPAC52DB — With AUX Contact Control Relay Panel BAY24VRPAC52DB • 5 Heat (Gas, Oil, Electric)/2 Cool/Heat Pump/Dual Fuel • Optional remote indoor temperature connection point • Optional outdoor temperature connection point • LED stage indicators • Removable low voltage terminal blocks for easy service and replacement • Humidifier Control • AUX Contacts -Whole-home Dehumidifier Control -Ventilation Control For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-3 Dimensions: • 8.0" width x 9.3" height x 1.9" depth Storage Temperature: • -40° to 175°F, 5% - 95% RH non-condensing Operating Temperature: • -40° to 150°F, 5% - 95% RH non-condensing Effective 7/1/12 14-1011-28 AccuLink™ Platinum ZV Control Component Overview Communicating System Communicating System Control AZONE950AC52ZA Wireless Home Network Indoor Unit Outdoor Unit Wired Remote Indoor Sensor1 ZZSENSAL0400AA 1 Optional Accessory 24V System 24V System Relay Panel Control AZONE950AC52ZA Wireless Home Network Wired Remote Indoor Sensor12 ZZSENSAL0400AA Wired Remote Outdoor Sensor BAYSEN01ATEMPA13 Relay Panel BAY24VRPAC52D* Indoor Unit Outdoor Unit 1 Optional Accessory 2 Can alternatively be connected to the Relay Panel 3 Can alternatively be connected to the 950 Control For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-4 Effective 7/1/12 14-1011-28 AccuLink™ Zoning Assembly ZZONEPNLAC52ZB Discharge Air Sensor Static Probes Static Pressure Transducer Transducer Enclosure Zone Panel Connecting Tubing American Standard Variable Speed Indoor Unit (Air handler/Gas Furnace) required. Includes: • Four Zone Communicating Zone Panel with discharge air sensor, static pressure transducer and housing, supply, return air static probes and connecting tubing, and three wiring blocks • Automatically sets maximum CFM per zone • Compatible with 24 Volt systems with the addition of 24 Volt relay panel • Controls 24 Volt power open, power ZZONEPNLAC52ZB close modulating dampers • Auto detects installed dampers • Supports 2-wire (ZZSENSAL0400AA) and 3-wire (AZONE940) zone sensors • Adjustable damper motor travel times of 15 to 60 seconds • Requires field supplied 24 volt power supply • Up to four 1.5 VA dampers can be wired in parallel to each zone • Backlit LCD display for easy setup and service • Optional return and mixed air sensors are available • Removable low voltage terminal blocks for easy service and replacement AccuLink™ Zone Expander Panel (Required with more than 4 zones) ZZONEEXPAC52ZA* • Expands the maximum number of zones per system to eight • Controls 24 Volt power open, power close modulating dampers • Auto detects installed dampers • Supports 2-wire (ZZSENSAL0400AA) and 3-wire (AZONE940) zone sensors • Adjustable damper motor travel times of 15 to 60 seconds • Requires field supplied 24 Volt power supply Zone Panel ZZONEEXPAC52ZA Dimensions: • 8.0" width x 9.3" height x 1.9" depth Storage Temperature: • -40° to 175°F, 5% to 95% RH non-condensing Operating Temperature: • -40° to 150°F, 5% to 95% RH non-condensing *This is the same Zone Panel that ships as part of the Zoning Assembly For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-5 Effective 7/1/12 14-1011-28 AccuLink™ Zoning Component Overview ZonedCommunicating CommunicatingSystem System Zoned AccuLink™ Control Outdoor Unit Indoor Unit Wireless Home Network Static Pressure Sensor 24V Trans. Zone Panel Zones 1-4 (ZZONEPNLAC52ZA) Discharge Return Mixed Optional Temperature Sensors Zone Panel Zones 1-4 Wired Zone Sensors* (non-display) (ZZSENSAL0400AA) AND/OR Modulating Dampers Wired Zone Sensors* (with display) (AZONE940) Zones 5-8 Wired Zone Sensors* (non-display) (ZZSENSAL0400AA) Zone Panel Modulating Dampers AND/OR Zone Expander Zones 5-8 (ZZONEEXPAC52ZA) Wired Zone Sensors* (with display) (AZONE940) * Up to 4 AZONE940 Zone Sensors with display may be used with each ZZONEPNLAC52ZA Zone Panel. AZONE940 Zone Sensors may be used in all zones or in conjunction with zones using non-display ZZSENSAL0400AA sensors. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-6 Effective 7/1/12 14-1011-28 AccuLink™ Zoning Component Overview (Cont.) Zoned 24V System Zoned 24V AccuLink™ Control Relay Panel Relay Panel BAY24VRPAC52D* Indoor Unit Wireless Home Network Wired Remote Outdoor Sensor BAYSEN01ATEMPA 13 Static Pressure Sensor Outdoor Unit Discharge Optional Temperature Sensors 24V Trans. Zone Panel Zones 1-4 (ZZONEPNLAC52ZA) Return Mixed Wired Zone Sensors* (non-display) (ZZSENSAL0400AA) Zone Panel Zones 1-4 AND/OR Wired Zone Sensors* (with display) (AZONE940) Modulating Dampers Wired Zone Sensors* (non-display) (ZZSENSAL0400AA) Zones 5-8 Zone Panel AND/OR Modulating Dampers Zone Expander Zones 5-8 (ZZONEEXPAC52ZA) Wired Zone Sensors* (with display) (AZONE940) * Up to 4 AZONE940 Zone Sensors with display may be used with each ZZONEPNLAC52ZA Zone Panel. AZONE940 Zone Sensors may be used in all zones or in conjunction with zones using non-display ZZSENSAL0400AA sensors. 1 Optional Accessory 2 Can alternatively be connected to the Relay Panel 3 Can alternatively be connected to the 950 Control For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-7 Effective 7/1/12 14-1011-28 24 Volt Modulating Dampers Round Dampers • 24 VAC Powered open/Powered closed • Three wire connection - 18 gauge • 1.5 VA damper actuator with 60 second travel time • 18 in. lbs. of torque • Manual gear release • Screw terminal blocks • Flexible shutoff seal provides 98% closure Round Dampers Table AL-8-A — Specifications: Round Dampers Model Power Fits Round NumberSupply Description Duct Size ZDAMPRDMA0004A ZDAMPRDMA0006A ZDAMPRDMA0007A ZDAMPRDMA0008A ZDAMPRDMA0009A ZDAMPRDMA0010A ZDAMPRDMA0012A ZDAMPRDMA0014A ZDAMPRDMA0016A ZDAMPRDMA0018A ZDAMPRDMA0020A 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC Round Round Round Round Round Round Round Round Round Round Round 4" 6" 7" 8" 9" 10" 12" 14" 16" 18" 20" Retro-Fit Round Dampers Retro-Fit Round Dampers • • • • • • • • 24 VAC Powered open/Powered closed Three wire connection - 18 gauge Slip-In-Design installs quickly 1.5 VA damper actuator with 60 second travel time 18 in. lbs. of torque Manual gear release Screw terminal blocks Flexible shutoff seal provides 98% closure Table AL-8-B — Specifications: Retrofit Round Dampers Model Power NumberSupply Description ZDAMPRRMA0004A ZDAMPRRMA0005A ZDAMPRRMA0006A ZDAMPRRMA0007A ZDAMPRRMA0008A ZDAMPRRMA0009A ZDAMPRRMA0010A For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC CCZS-8 Retrofit Round Retrofit Round Retrofit Round Retrofit Round Retrofit Round Retrofit Round Retrofit Round Fits Round Duct Size 4" 5" 6" 7" 8" 9" 10" Effective 7/1/12 14-1011-28 24 Volt Modulating Dampers Side Mount Rectangular Dampers with Side Mount Actuator • 24 VAC Powered open/Powered closed • Three wire connection - 18 gauge • 1.5 VA damper actuator with 60 second travel time • 18 in. lbs. of torque • Manual gear release H Ew C E xcellen ce Withou tC omprim ise C ONT MA R OLS -ND INC . 4 24 18 VAC in-l 50/ MAN b 60H GEA UAL (2N m) z REL R EAS E ! 1.5VA 35s 1W Class Supp 2 ly • • • • Screw terminal blocks 97% leak proof rating Sturdy aluminum blades and frame Motor is always located on the second dimension of the model number, i.e ZDAMP*MMA1012A will have the motor mounted on the 12" dimension PC PO COM OPE N CLO SED W Rectangular Dampers with Side Mount Actuator Table AL-9-A — Specifications: Rectangular Dampers with Side Mount Actuator Model Power Number Supply Description ZDAMPSMMA0806A ZDAMPSMMA0808A ZDAMPSMMA1006A ZDAMPSMMA1008A ZDAMPSMMA1010A ZDAMPSMMA1206A ZDAMPSMMA1208A ZDAMPSMMA1210A ZDAMPSMMA1212A ZDAMPSMMA1406A ZDAMPSMMA1408A ZDAMPSMMA1410A ZDAMPSMMA1412A ZDAMPSMMA1414A ZDAMPSMMA1606A ZDAMPSMMA1608A ZDAMPSMMA1610A ZDAMPSMMA1612A ZDAMPSMMA1614A ZDAMPSMMA1616A ZDAMPSMMA1806A ZDAMPSMMA1808A ZDAMPSMMA1810A ZDAMPSMMA1812A ZDAMPSMMA1814A ZDAMPSMMA1816A ZDAMPSMMA1818A ZDAMPSMMA2006A ZDAMPSMMA2008A ZDAMPSMMA2010A ZDAMPSMMA2012A ZDAMPSMMA2014A ZDAMPSMMA2016A ZDAMPSMMA2018A ZDAMPSMMA2020A For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator CCZS-9 Uncrated Dimensions (in.) WH 8 8 10 10 10 12 12 12 12 14 14 14 14 14 16 16 16 16 16 16 18 18 18 18 18 18 18 20 20 20 20 20 20 20 20 6 8 6 8 10 6 8 10 12 6 8 10 12 14 6 8 10 12 14 16 6 8 10 12 14 16 18 6 8 10 12 14 16 18 20 Effective 7/1/12 14-1011-28 24 Volt Modulating Dampers Side Mount Table AL-10-A — Specifications: Rectangular Dampers with Side Mount Actuator (continued) Model Power Number Supply Description ZDAMPSMMA2206A ZDAMPSMMA2208A ZDAMPSMMA2210A ZDAMPSMMA2212A ZDAMPSMMA2214A ZDAMPSMMA2216A ZDAMPSMMA2218A ZDAMPSMMA2220A ZDAMPSMMA2222A ZDAMPSMMA2406A ZDAMPSMMA2408A ZDAMPSMMA2410A ZDAMPSMMA2412A ZDAMPSMMA2414A ZDAMPSMMA2416A ZDAMPSMMA2418A ZDAMPSMMA2420A ZDAMPSMMA2422A ZDAMPSMMA2424A ZDAMPSMMA2606A ZDAMPSMMA2608A ZDAMPSMMA2610A ZDAMPSMMA2612A ZDAMPSMMA2614A ZDAMPSMMA2616A ZDAMPSMMA2618A ZDAMPSMMA2620A ZDAMPSMMA2622A ZDAMPSMMA2624A ZDAMPSMMA2626A ZDAMPSMMA2806A ZDAMPSMMA2808A ZDAMPSMMA2810A ZDAMPSMMA2812A ZDAMPSMMA2814A ZDAMPSMMA2816A ZDAMPSMMA2818A ZDAMPSMMA2820A ZDAMPSMMA2822A ZDAMPSMMA2824A ZDAMPSMMA2826A ZDAMPSMMA2828A ZDAMPSMMA3006A ZDAMPSMMA3008A ZDAMPSMMA3010A ZDAMPSMMA3012A ZDAMPSMMA3014A ZDAMPSMMA3016A ZDAMPSMMA3018A ZDAMPSMMA3020A ZDAMPSMMA3022A ZDAMPSMMA3024A ZDAMPSMMA3026A ZDAMPSMMA3028A ZDAMPSMMA3030A For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator Rectangular-Side Mount Actuator CCZS-10 Uncrated Dimensions (in.) WH 22 22 22 22 22 22 22 22 22 24 24 24 24 24 24 24 24 24 24 26 26 26 26 26 26 26 26 26 26 26 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 6 8 10 12 14 16 18 20 22 6 8 10 12 14 16 18 20 22 24 6 8 10 12 14 16 18 20 22 24 26 6 8 10 12 14 16 18 20 22 24 26 28 6 8 10 12 14 16 18 20 22 24 26 28 30 Effective 7/1/12 14-1011-28 24 Volt Modulating Dampers Bottom Mount Rectangular Dampers with Bottom Mount Actuator • 24 VAC Powered open/Powered closed 35s Class2 Supply ! MANUAL GEAR RELEASE Comprimise 24 VAC 50/60Hz 18 in-lb (2Nm) MA-ND4 CONTROLS INC. Excellence Without H CLOSED PC PO COM 1.5VA 1W OPEN • Three wire connection - 18 gauge W Rectangular Dampers with Bottom Mount Actuator • 1.5 VA damper actuator with 60 second travel time • 18 in. lbs. of torque • Manual gear release • Screw terminal blocks • 97% leak proof rating • Sturdy aluminum blades and frame • Motor is always located on the second dimension of the model number, i.e ZDAMP*MMA1012A will have the motor mounted on the 12" dimension Table AL-11-A — Specifications: Rectangular Dampers with Bottom Mount Actuator Model Power Number Supply Description ZDAMPBMMA0810A ZDAMPBMMA0812A ZDAMPBMMA0814A ZDAMPBMMA0816A ZDAMPBMMA0818A ZDAMPBMMA0820A ZDAMPBMMA0822A ZDAMPBMMA0824A ZDAMPBMMA0826A ZDAMPBMMA0828A ZDAMPBMMA0830A ZDAMPBMMA1012A ZDAMPBMMA1014A ZDAMPBMMA1016A ZDAMPBMMA1018A ZDAMPBMMA1020A ZDAMPBMMA1022A ZDAMPBMMA1024A ZDAMPBMMA1026A ZDAMPBMMA1028A ZDAMPBMMA1030A ZDAMPBMMA1214A ZDAMPBMMA1216A ZDAMPBMMA1218A ZDAMPBMMA1220A ZDAMPBMMA1222A ZDAMPBMMA1224A ZDAMPBMMA1226A ZDAMPBMMA1228A ZDAMPBMMA1230A ZDAMPBMMA1416A ZDAMPBMMA1418A ZDAMPBMMA1420A ZDAMPBMMA1422A ZDAMPBMMA1424A ZDAMPBMMA1426A ZDAMPBMMA1428A ZDAMPBMMA1430A ZDAMPBMMA1618A ZDAMPBMMA1620A ZDAMPBMMA1622A ZDAMPBMMA1624A ZDAMPBMMA1626A ZDAMPBMMA1628A ZDAMPBMMA1630A ZDAMPBMMA1820A ZDAMPBMMA1822A ZDAMPBMMA1824A ZDAMPBMMA1826A ZDAMPBMMA2022A ZDAMPBMMA2024A For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC 24 VAC CCZS-11 Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Rectangular-Bottom Mount Actuator Uncrated Dimensions (in.) HW 8 8 8 8 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 10 10 12 12 12 12 12 12 12 12 12 14 14 14 14 14 14 14 14 16 16 16 16 16 16 16 18 18 18 18 20 20 10 12 14 16 18 20 22 24 26 28 30 12 14 16 18 20 22 24 26 28 30 14 16 18 20 22 24 26 28 30 16 18 20 22 24 26 28 30 18 20 22 24 26 28 30 20 22 24 26 22 24 Effective 7/1/12 14-1011-28 24 Volt Modulating Dampers Table AL-12-A — Rectangular Damper Net Free Area “B” “B1” 35s Class2 Supply ! MANUAL GEAR RELEASE Comprimise 24 VAC 50/60Hz 18 in-lb (2Nm) MA-ND4 Excellence Without CONTROLS INC. “A” CLOSED PC PO COM 1.5VA 1W OPEN “A1” Listed Size Actual Outside Size Actual Inside Size 8 10 7.813 9.813 11.813 13.813 15.813 17.813 19.813 21.813 23.813 25.813 27.813 29.813 12 14 16 18 20 22 24 26 28 30 Act. Outside Size B Wide A A1 5.813 7.813 9.813 Act. Inside Size B1 3 3 4 5 6 6 5.812 4.313 19.5 28.1 34.9 41.6 8 7.812 6.313 28.5 41.1 51.0 60.9 11.813 13.813 15.813 17.813 19.813 21.813 23.813 25.813 27.813 7 7 8 9 10 11 11 48.6 55.1 63.8 70.5 77.3 84.0 90.8 99.4 70.8 80.7 93.3 103.2 113.1 123.0 132.9 145.5 10 9.812 8.313 37.5 54.2 67.2 80.2 93.2 106.3 122.9 135.9 148.9 162.0 175.0 191.6 12 11.812 10.313 46.5 67.2 83.3 99.5 115.7 131.8 152.5 168.6 184.8 200.9 217.1 237.7 14 13.812 12.313 55.6 80.2 99.5 118.8 138.1 157.4 182.0 201.3 220.6 239.9 259.2 283.8 16 15.812 14.313 64.6 93.2 115.7 138.1 160.5 183.0 211.6 234.0 256.4 278.9 301.3 329.9 18 17.812 16.313 73.6 106.3 131.8 157.4 183.0 208.5 241.1 266.7 292.3 317.8 343.4 376.0 20 19.812 18.313 82.7 119.3 148.0 176.7 205.4 234.1 270.7 299.4 328.1 356.8 385.5 422.1 22 21.812 20.313 91.7 132.3 164.2 196.0 227.8 259.6 300.3 332.1 363.9 395.8 427.6 468.2 24 23.812 22.313 100.7 145.4 180.3 215.3 250.2 285.2 329.8 364.8 399.8 435.2 469.7 514.3 26 25.812 24.313 109.8 158.4 196.5 234.6 272.7 310.8 359.4 397.5 435.6 473.7 511.8 560.4 28 27.812 26.313 118.8 171.4 212.6 253.9 295.1 336.3 389.0 430.2 471.4 512.7 553.8 606.5 30 29.812 28.313 127.8 184.4 228.8 273.2 317.5 361.9 418.5 462.9 507.3 551.6 596.0 652.6 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-12 Listed Size High No. of Blades Effective 7/1/12 14-1011-28 Programmable 7 Day Comfort Controls ACONT900AC43UA - AccuLink™ AccuLinkTM ACONT900A • Communicating Programmable • Interactive Touchscreen • Continuous Comfort-R™ • Smart Continuous Fan • Adjustable Continuous Fan, 25-100% • Multiple Filter Reminders • Humidity Sensor • Dehumidification Control • Window Frost Control • Dual Fuel Compatible • BAYCOVR600A - Wall cover plate • Energy Saver ACONT800AS11AA ACONT800A • Interactive Touchscreen • Effortless Programming • Large, Backlit Display • Streamlined Design • Armchair Programming • Real Time Clock • Visual Reminder Cues • BAYCOVR600A - Wall cover plate • Energy Saver ACONT802AS32DA ACONT802A • Interactive Touchscreen • Effortless Programming • Large, Backlit Display • Streamlined Design • Armchair Programming • Real Time Clock • Visual Reminder Cues • BAYCOVR600A - Wall cover plate • Energy Saver ACONT803AS32DA ACONT803A • Built-in Humidity Sensor • Dehumidification Control • Interactive Touchscreen • Effortless Programming • Large, Backlit Display • Streamlined Design • Armchair Programming • Real Time Clock • Visual Reminder Cues • BAYCOVR600A - Wall cover plate • Energy Saver BAYCOVR600A Application: • Use with ACONT800/900A Series Comfort Controls Application: • 4 Heat/2 Cool (Gas, Oil or Electric) • BAYTAM00AC00UA - Communicating Telephone Access module Dimensions: • 6.02" w x 4.62" h x 1.35" d • Finish: Bright White Application: • 1 Heat/1 Cool (Gas, Oil or Electric) • 1 Heat/0 Cool (Gas, Oil or Electric) • 0 Heat/1 Cool • ZZSENSAL0800AA - Remote Indoor Temperature Sensor Dimensions: • 6.02" w x 4.62" h x 1.35" d • Finish: Bright White Application: • Up to 3 Heat/2 Cool (Gas, Oil or Electric)/HP • ZZSENSAL0800AA - Remote Indoor Temperature Sensor Dimensions: • 6.02" w x 4.62" h x 1.35" d • Finish: Bright White Application: • Up to 3 Heat/2 Cool (Gas, Oil or Electric)/HP • ZZSENSAL0800AA - Remote Indoor Temperature Sensor Dimensions: • 6.02" w x 4.62" h x 1.35" d • Finish: Bright White Dimensions: • 7.87" w x 5.50" h • Finish: Bright White BAYCOVR600A For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-13 Effective 7/1/12 14-1011-28 Programmable 5/2 Day Comfort Controls ACONT600AF11MA • 1 Heat/1 Cool • 5/2 or 5/1/1 Programming • Simple to Install and Use • Front Wired (Wires attach to wall plates) • Standard Wiring Terminal Block • Easy to follow Sequential Programming • Inside and set temperatures displayed simultaneously • No auxiliary heat capability • Plain language (no symbols) • Easy battery access • Easy to understand soft key controls • BAYCOVR700A - Wall cover plate • Energy Saver ACONT600A ACONT602AF22MA ACONT602A • 2 Heat/2 Cool • 5/2 or 5/1/1 Programming • Simple to Install and Use • Front Wired (Wires attach to wall plates) • Standard Wiring Terminal Block • Easy to follow Sequential Programming • Inside and set temperatures displayed simultaneously • Plain language (no symbols) • Easy battery access • Easy to understand soft key controls • BAYCOVR700A - Wall cover plate • Energy Saver BAYCOVR700A Application: • Use with ACONT600A/602A Series Comfort Controls Application: • 1 stage heat pump, 0 stage Aux Heat • 1 stage cool, 1 stage heat (Gas, electric, or oil) • 1 stage cool, 0 stage heat • 0 stage cool, 1 stage heat (Gas, electric, or oil) Dimensions: • 5.81" w x 3.56" h x 1.50" d • Finish: Bright White Application: • 1 stage cool, 1 stage heat • 2 stage cool, 1 stage heat • 1 stage cool, 2 stage heat • 2 stage cool, 2 stage heat • 1 stage cool, 0 stage heat • 0 stage cool, 1 stage heat (Gas, electric, or oil) • 1 stage heat pump, 0 stage Aux Heat • 1 stage heat pump, 1 stage Aux Heat Dimensions: • 5.81" w x 3.56" h x 1.50" d • Finish: Bright White Dimensions: • 6.87" w x 5.0" h • Finish: Bright White BAYCOVR700A For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-14 Effective 7/1/12 14-1011-28 Non-Programmable Comfort Controls ACONT402AN32DA • Auto Changeover • Backlit Display & Keys • Comfort Information Compartment • Energy Savings Mode • Filter Reminder • BAYSEN01ATEMPAA-Outdoor Temperature Sensor included* • Keypad Lock Application (3-9 Wire Hookup -2 for Outdoor Sensor) Heat Pump* or A/C • 3 Heat/2 Cool • No external Dual Fuel Kit Required • Do not use with TAYPLUS103A • ZZSENSAL0400AA - Remote Indoor Temperature Sensor ACONT402A ACONT401AN21MA ACONT401A • Auto Changeover • Backlit Display & Keys • Comfort Information Compartment • Energy Savings Mode • Filter Reminder • Outdoor Temperature Sensor • Keypad Lock Application (3-9 Wire Hookup -2 for Outdoor Sensor) Heat Pump* or A/C • 1 Stage Heat Pump**, 1 Stage Aux Heat • 1 Stage Heat Pump**, 0 Stage Aux Heat • 1 Stage Cool, 2 Stage Heat (Gas, Electric or Oil*) ACONT200AN11AA1 • Auto Changeover • Backlit Display & Keys • Comfort Information Compartment • Energy Savings Mode • Filter Reminder • Key Pad Lock ACONT200A For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. Dimensions: • 6.75" w x 4.52" h x 1.20" d • Finish: Bright White * Requires external relay for oil furnace applications. * Installation is required for outdoor temperature sensing and display • 1 Stage Cool, 1 Stage Heat (Gas, Electric or Oil*) • 1 Stage Cool, 0 Stage Heat • 0 Stage Cool, 2 Stage Heat (Gas, Electric or Oil*) • 0 Stage Cool, 1 Stage Heat (Gas, Electric or Oil*) Dimensions: • 6.75" w x 4.52" h x 1.20" d • Finish: Bright White * Requires external relay for oil furnace applications. ** External TAYPLUS103A required for dual fuel applications. BAYSEN01ATEMPA required for outdoor temperature sensing and display Application (4 wire hookup - power stealing)* • 1 Heat/1 Cool (Gas, Oil or electric) • 1 Heat/0 Cool (Gas, Oil or electric) • 0 Heat/1 Cool • Finish: Bright White Dimensions: • 4.25" w x 5.33" h x 1.20" d 1 Power Stealing 4 Wire - Resistor Terminal in Box. 4 - wire system to supply power with heating mode; both resistors must be installed for proper operation. CCZS-15 Effective 7/1/12 14-1011-28 Remote Sensors BAYSEN02ATEMPA • Outdoor Temperature Sensor for use with ACONT800, 802, 803 • Accuracy +/– 1°F from –40 to 120°F BAYSEN01ATEMPA • Outdoor Temperature Sensor for use with AccuLink™ Platinum ZV Control, AccuLink™ Zoning and ACONT401A • Accuracy +/– 1.5°F over 32°F to 100°F • Display Range -40°F to 140°F ZZSENSAL0400AA • Indoor Sensor for use with AccuLink™ Platinum ZV Control, AccuLink™ Zoning and ACONT402A Comfort Controls • Operating Ambient Temperature Range: 20° to 120°F (-6.7° to 48.9°C) • Display Range: 20° to 120°F (-6.7° to 48.9°C) • Sensor Accuracy: +/–.5°F at 75°F • Operating Relative Humidity: 5% to 90% non-condensing ZZSENSAL0800AA • Indoor Temperature Sensor for use with ACONT800, 802, 803 • Operating Ambient Temperature Range: 20° to 120°F (-6.7° to 48.9°C) • Display Range: 0 to 99°F (-18 to 37°C) • Sensor Accuracy: +/–1.5°F at 70°F (+/–.84 at 21°C) • Operating Relative Humidity: 5% to 95% non-condensing For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-16 Dimensions in in. (mm): • 1.54 (39)w x 1.93 (49)h x .625 (1.6)d • Storage Temperature: -40° to 140°F (-40° to 60°C) • Finish: White Dimensions in in. (mm): • 1.54 (39)w x 1.93 (49)h x .625 (1.6)d • Storage Temperature: -40° to 140°F (-40° to 60°C) • Finish: White Effective 7/1/12 14-1011-28 Indoor Fan Delay Relay Kit BAY24X045 • For application to furnaces and air handlers with cooling coils equipped with capillary tube or 15% bleed expansion valve components. • This kit allows the indoor fan to continue to run a short time after the outdoor unit shuts off for increased cooling efficiency. • The kit contains: 1 solid state time delay relay with four (4) color coded wires, 1 wiring diagram, 1 notice label, 1 mounting screw. Outdoor Thermostat Kit TAYSTAT250B • The outdoor thermostat (ODT) is designed to turn "ON" the supplementary heater at a pre-selected outdoor temperature. • The number and setting of the ODT is dependent on the heat loss of the structure and capacity of the heating system installed. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-17 • This model ODT gives a temperature range for 44°F. to -10°F. (See figure 1 for settings). The switching action is single pole/double throw, opening on temperature rise and closing on temperature fall, completing the circuit through the thermostat. Effective 7/1/12 14-1011-28 Non-Programmable Comfort Controls for ReliaTel™ Units ASYSTAT095A • One-touch temperature control. • Large, clear, backlit display is easy to read, even in the dark. • Displays both room temperature and temperature setting. • Removable battery holder for fast, easy replacement. • Built-in compressor protection. • Focus Pro 3 Heat/ 2 Cool PHASED OUT ASYSTAT095A Programmable Comfort Controls for ReliaTel™ Units ASYSTAT090A • Large, Clear Display with Backlighting — Current temperature, set temperature and time are easy-toread and all are displayed on the main screen. • Menu Driven Programming — Provides guidance through the scheduling process, showing only necessary information and choices on each screen. • Ability to Select Multiple Days — Allows easy customizing for unique schedules. • Real-Time Clock—Keeps time during power failure; automatically updates for daylight saving time. • Armchair Programming — Can remove thermostat from wall to set the schedule. • Precise Temperature Control (±1 °F) — reliable, consistent comfort. • Multiple OVERRIDE options — Can modify schedule for a specific period of time (up to 365 days). • Outdoor Temperature Indication — Displays current outdoor temperature to help plan outdoor activities. • 2 Heat/2 Cool PHASED OUT ASYSTAT090A ASYSTAT092A ASYSTAT092A • Large, Clear Display with Backlighting — Current temperature, set temperature and time are easy-toread and all are displayed on the main screen. • Menu Driven Programming — Provides guidance through the scheduling process, showing only necessary information and choices on each screen. • Ability to Select Multiple Days — Allows easy customizing for unique schedules. • Real-Time Clock — Keeps time during power failure; automatically updates for daylight savings. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. • Armchair Programming — Can remove thermostat from wall to set the schedule. Precise Temperature Control (±1 °F) — reliable, consistent comfort. • Multiple OVERRIDE options — Can modify schedule indefinitely or for a specific period of time. • Programmable Fan — Increases indoor air quality when combined with air cleaning equipment. • Outdoor Temperature Indication — Displays current outdoor temperature to help plan outdoor activities. • 2 Heat/2 Cool Commercial Vision Pro PHASED OUT CCZS-18 Effective 7/1/12 14-1011-28 Programmable Comfort Controls for ReliaTel™ Units ASYSTAT800A Phased Out PHASED OUT • Wall mounted remote space sensor • For use with ASYSTAT090A, ASYSTAT092A, and ASYSTAT093A programmable thermostats ASYSTAT800A For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-19 Effective 7/1/12 14-1011-28 Zone Sensor Unit Installation The zone sensor provides the operator control and zone temperature sensing functions for use with electronic unit controls. Refer to the appropriate unit installation manual for interconnecting wiring instructions. Zone Sensor Location To ensure proper operation, select a location on an interior wall, at a height approximately 5 feet above the floor, with freely circulating air of average temperature. Avoid Locations: • Behind doors or in corners where air does not freely circulate. • On an outside wall or any wall with unheated (uncooled) areas behind the zone sensor. • Where direct sunlight or any Source: of radiant heat could affect the temperature measurements. • In line with the discharge air from the unit being controlled. Mount the zone sensor base on the wall or optional mounting plate with the wires routed through the wire access hole in the base of the zone sensor. ZONE SENSOR CONTROLS Emergency Heat/Heat/Auto/Off/ Cool This switch determines whether the unit operates in emergency heat (EM. HEAT - for heat pumps only), heating (HEAT), automatically changing from heating to cooling as required (AUTO), heating and cooling functions disabled (OFF), or cooling (COOL). Fan Auto/Fan On This switch determines whether the indoor fan operates during cooling and heating cycles only (FAN AUTO) or runs continuously (FAN ON). Temperature Adjustments One or two temperature adjustment controls are provided to set the desired temperature or temperature range (for unit mode AUTO). If two controls are present, the blue control sets the desired temperature for cooling and the red control sets the desired temperature for heating. Temperature Indicator This indicates the temperature in the zone. The indicator has been factory calibrated and should not normally require adjustment. If adjustment is needed, it can be accomplished by slowly rotating a small screwdriver in the slot on the back of the indicator until the correct temperature is obtained. Optional Remote Sensor When using the optional remote sensor (BAYSENS077A), it should be located in the space that is to be controlled. Wire according to the interconnecting wiring diagrams in the unit IOM. Installation: 18-HD60D41 Source: Clarksville For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-20 Effective 7/1/12 14-1011-28 Micro Control Zone Sensors ASYSTAT106A Manual Changeover • 4 wires required. • Single Setpoint for 3-25 Tons Electric/Electric TCD/TCH and Gas/ Electric Systems YCD/YCH • Can be used with Remote Sensor (ASYSTAT669) ASYSTAT107A Manual Changeover • 4-6 wires required. • Single Setpoint for Heat Pump Systems (WCD/WCH 3-20 Tons) • Can be used with Remote Sensor (ASYSTAT669) ASYSTAT108A Automatic Changeover • 5 wires required. • Dual Setpoint for Electric/Electric and Gas Electric Systems (TCD/TCH and YCD/YCH 3-25 Tons) • Can be used with Remote Sensor (ASYSTAT669) ASYSTAT109A Automatic Changeover • 5-7 wires required. • Dual Setpoint for Heat Pump Systems (WCD/WCH 3-20 Tons) • Can be used with Remote Sensor (ASYSTAT669) ASYSTAT709A/707A LCD Digital Display Zone Sensor • 3-7 wires required. • Non-Programmable Zone Sensor with a digital display • ASYSTAT709A - Cool/Gas • ASYSTAT707A - Heat Pumps PHASED OUT Zone Sensors must be used with Micro Control units. Vendor Thermostats which use Triac outputs are not recommended with Micro Control units. Major features lost by using a Conventional Thermostat include the following: • No diagnostics • Proportional Integral control • No smart recovery in the heating mode (heat pumps) • 2-stage electric heat (heat pumps) • Stand alone set up and set back for unoccupied features • Intelligent fall back (unit can run on default value with outdoor air sensor) For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-21 • • • • • Control wiring size may be increased Remote sensing capability Space temperature averaging Supply air tempering Economizer preferred cooling is lost (compressor operation is locked out below 50°F) Effective 7/1/12 14-1011-28 Electronic Programmable Zone Sensors For ReliaTel™ Units ASYSTAT777A • Automatic or Manual Changeover with System Lights • Use With: 3 – 10 Ton Precedent™ Units 12.5 – 25 Ton Voyager™ Units • Digital display indicating the time of day, the day of the week, room temperature, current program operating mode, and current active stage • Continuous or 3 hour timed override • Two occupied, two unoccupied programs per day • L.C.D. readout in F or C (Celsius) and 12 or 24-hour clock • Keyboard disable to prevent tampering • Programming on a 7-day basis • Status indication lights displayed in Digital Display • Auxiliary relay (Form 1C) • Auto Fan During Setback • No Anticipator Required • No Battery Required • No accessories required. Each unit is complete and ready for installation • Remote Room Sensor (ASYSTAT669) • Finish: Pantone Cool Gray #2C • Replacement: SEN-0415 • Installation: 18-HD60D29 • Source: Clarksville Integrated Comfort™ Systems Sensors For ReliaTel™ Units ASYSTAT669 • Room Sensor • Used with Integrated Comfort™ Systems • Used With: 3 - 10 Ton Precedent™ Units 12.5 - 25 Ton Voyager™ Units For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. CCZS-22 • • • • Finish: Pantone Cool Gray #2C Replacement: SEN01448 Installation: Included with sensor Source: St. Paul GCC/Clarksville Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 1½-5 Tons Table PC-1-A — 4TCY4 - Platinum ZM (Previously Allegiance® 14) Convertible Packaged Cooling - R-410A Cooling Model Capacity Shipping Number (Btuh) SEER/EERWeight MCA 4TCY4 Platinum ZM Max Fuse Sound Rating Cabinet Dimensions (in.) H x D xW 4TCY4 – 208-230/1/60 4TCY4024A1000A 23,400 14.00/12.00 444 16.5 25 68 36 x 43 x 51 4TCY4030A1000A 30,000 14.00/12.00 444 19.1 30 71 36 x 43 x 51 4TCY4036B1000A 38,000 14.20/12.00 450 24.6 40 69 36 x 43 x 51 4TCY4042B1000A 42,000 14.25/12.00 607 31.6 50 74 38 x 46 x 61 4TCY4048B1000A 48,000 14.20/12.00 607 35.4 50 72 38 x 46 x 61 4TCY4060A1000A 60,000 14.00/12.00 612 42.3 60 76 42 x 46 x 61 4TCY4 – 208-230/3/60 4TCY4036A3000A 36,000 14.20/11.60 450 19.8 30 69 36 x 43 x 51 4TCY4048A3000A 48,500 14.20/11.90 607 26.4 40 72 38 x 46 x 61 4TCY4060A3000A 60,000 14.00/12.00 612 30.6 45 76 42 x 46 x 61 Table PC-1-B — 4TCX3 - Gold XM (Previously Allegiance® 13) Convertible Packaged Cooling - R-410A Cooling Model Capacity Shipping Number (Btuh) SEER/EERWeight MCA Max Fuse Sound Rating Cabinet Dimensions (in.) H x D xW 4TCX3 – 208-230/1/60 4TCX3018A1000A 18,000 13.00/11.00 444 10.1 15 69 36 x 43 x 51 4TCX3024A1000A 24,000 13.00/11.20 444 13.6 20 70 36 x 43 x 51 4TCX3030A1000A 29,600 13.00/11.00 445 21.7 35 72 36 x 43 x 51 4TCX3036A1000A 36,000 13.00/11.00 450 23.2 35 72 36 x 43 x 51 4TCX3042A1000A 42,000 13.00/11.00 523 27.9 45 72 38 x 46 x 61 4TCX3048A1000A 46,500 13.00/11.00 607 31.1 50 72 38 x 46 x 61 4TCX3060A1000A 60,000 13.00/11.00 610 43.5 60 72 40 x 46 x 61 4TCX3 – 208-230/3/60 4TCX3036A3000A 36,000 13.00/11.00 450 18.2 30 72 36 x 43 x 51 4TCX3048A3000A 46,500 13.00/11.00 607 23.6 35 72 38 x 46 x 61 4TCX3060A3000A 60,000 13.00/11.00 610 31.7 50 72 40 x 46 x 61 4TCX3 – 460/3/60 4TCX3036A4000A 36,000 13.00/11.00 450 8.7 15 72 36 x 43 x 51 4TCX3048A4000A 46,500 13.00/11.00 607 11.7 15 72 38 x 46 x 61 4TCX3060A4000A 60,000 13.00/11.00 610 19.5 25 72 40 x 46 x 61 4TCX3 Gold XM Table PC-1-C — 4TCC3 - Silver SI+ (Previously American Standard 13) Convertible Packaged Cooling - R-410A Cooling Model Capacity Shipping Number (Btuh) SEER/EERWeight MCA 4TCC3 Silver SI+ Max Fuse Sound Rating Cabinet Dimensions (in.) H x D xW 4TCC3 – 208-230/1/60 4TCC3018A1000A 18,000 13.00/11.00 444 10.1 15 74 36 x 42 x 49 4TCC3024A1000A 23,000 13.00/11.00 444 13.6 20 76 36 x 42 x 49 4TCC3030A1000A 28,000 13.00/10.40 445 21.7 35 75 36 x 42 x 49 4TCC3036A1000A 35,000 13.00/11.00 450 23.2 35 76 36 x 42 x 49 4TCC3042A1000A 40,000 13.00/11.00 523 27.9 45 78 38 x 45 x 59 4TCC3048A1000A 46,500 13.00/11.00 607 31.1 50 80 38 x 45 x 59 4TCC3060A1000A 58,000 13.00/11.00 610 43.5 60 79 40 x 45 x 59 4TCC3 – 208-230/3/60 4TCC3036A3000A 35,000 13.00/11.00 450 18.2 30 76 36 x 42 x 49 4TCC3048A3000A 46,500 13.00/11.00 607 23.6 35 80 38 x 45 x 59 4TCC3060A3000A 58,000 13.00/11.00 610 31.7 50 79 40 x 45 x 59 4TCC3 – 460/3/60 4TCC3036A4000A 35,000 13.00/11.00 450 8.7 15 76 36 x 42 x 49 4TCC3048A4000A 46,500 13.00/11.00 607 11.7 15 80 38 x 45 x 59 4TCC3060A4000A 58,000 13.00/11.00 610 19.5 25 79 40 x 45 x 59 For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-1 Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 1½-5 Tons 4TCY4 4TCX3 4TCC3 Table PC-2-A — Features2-5 1½-5 1½-5 • • • • • • • • • • • • • • • • • • • • • • • • • • SEER up to........................................................................................................................... 14.25 13.20 13.00 Exclusive Duration™ high efficiency compressor with internal overload protection........... ✔ ✔— Factory supplied charge........................................................................................................ R-410A R-410A R-410A Composite Vortica® indoor blower........................................................................................ ✔ ✔ ✔ High efficiency ECM indoor blower motor with Comfort-R™ airflow system....................... ✔— — Direct drive multi-speed indoor blower motors...................................................................... — ✔ ✔ All aluminum Spine Fin™ outdoor coil................................................................................. ✔ ✔ ✔ Swept-blade outdoor fan for quiet operation......................................................................... ✔ ✔— Architecturally integrated louvers and corner guards........................................................... ✔ ✔— All steel louvers..................................................................................................................... — — ✔ Cabinet constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint........................................................................................... ✔ ✔ ✔ Single stage cool................................................................................................................... ✔ ✔ ✔ Start kit - factory installed (single phase only)...................................................................... 3 1½ & 2 1½ & 2 High pressure cutout............................................................................................................. ✔ ✔ ✔ Low pressure cutout.............................................................................................................. 3-Phase Only 3-Phase Only 3-Phase Only Liquid line drier - factory installed......................................................................................... ✔ ✔ ✔ Non-bleed expansion valves on indoor coil........................................................................... ✔ ✔ ✔ Pressure taps, including liquid line taps, easily accessed and protected inside compressor compartment................................................................................................... ✔ ✔ ✔ Right side electrical service access for high and low voltage connections........................... ✔ ✔ ✔ Rugged steel basepan features deep drawn duct connections............................................ ✔ ✔ ✔ Steeply sloped composite drainpan...................................................................................... ✔ ✔ ✔ Ships in horizontal configuration and converts quickly for downflow.................................... ✔ ✔ ✔ Copper tube, aluminum fin indoor coil.................................................................................. ✔ ✔ ✔ All models are certified to UL 1995....................................................................................... ✔ ✔ ✔ 10-year compressor, 10-year outdoor coil and all other functional ✔ ✔ ✔ parts registered limited warranty (Residential Use)1................................................... Extended warranties available .......................................................................................... ✔ ✔ ✔ 1Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-2 Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 1½-5 Tons Table PC-3-A — Accessories Model Number Description 4TCY4 4TCX3 4TCC3 2-5 1½-51½-5 Shipping Weight BAYACCDOR1A.............. Hinged Filter Access Doorq ..................................................................................... 2-3 1½-3 1½-3 BAYACCDOR2A.............. Hinged Filter Access Doorq ..................................................................................... 3½-5 3½-5 3½-5 BAYADAP050A................ Adapter Curb (Cabinet A/B)....................................................................................... 2-3 1½-3 1½-3 BAYADAP051A................ Adapter Curb (Cabinet C)........................................................................................... 2-3 1½-3 1½-3 BAYADAP052A................ Adapter Curb (Cabinet A/B)....................................................................................... 3½-5 3½-5 3½-5 BAYADAP053A................ Adapter Curb (Cabinet C)........................................................................................... 3½-5 3½-5 3½-5 BAYADAP054A................ Adapter Curb (Cabinet D)........................................................................................... 3½-5 3½-5 3½-5 BAYASCT001.................. Anti-Short Cycle Timer4............................................................................................ ✔ ✔ ✔ BAYCCHT101A............... Crankcase Heater (230V) (Reciprocating)................................................................. 2 1½-2 1½-2 BAYCCHT102A............... Crankcase Heater (230V) (Scroll).............................................................................. 2½-5 2½-5 2½-5 BAYCCHT404B............... Crankcase Heater (460V) (Scroll) ............................................................................. 3,4,5 3,4,5 3,4,5 BAYCOVR112A............... 12" Duct Shourd (Covers Horizontal Ducts)5........................................................... 2-5 1½-5 1½-5 BAYCOVR118A............... 18" Duct Shourd (Covers Horizontal Ducts)5........................................................... 2-5 1½-5 1½-5 BAYCURB050A............... Flat Roof Full Perimeter Curb (Insulated) .................................... 74.......................... 2-3 1½-3 1½-3 BAYCURB051A............... Flat Roof Full Perimeter Curb (Insulated) .................................... 74.......................... 3½-5 3½-5 3½-5 BAYDMPR101A.............. 2-Position Motorized Fresh Air Damper16789 ................................................... 2-3 1½-3 1½-3 BAYDMPR102A.............. 2-Position Motorized Fresh Air Damper16789 ................................................... 3½-5 3½-5 3½-5 BAYECON101A............... Economizer with Barometric Relief (Downflow)12390 ......... 50.......................... 2-3 1½-3 1½-3 BAYECON102A............... Economizer with Barometric Relief (Downflow)12390 ......... 65.......................... 3½-5 3½-5 3½-5 BAYECON200A............... Economizer (Horizontal)1236 ................................................ 85.......................... 2-3 1½-3 1½-3 BAYECON201A............... Economizer (Horizontal)1236................................................. 85.......................... 3½-5 3½-5 3½-5 BAYECON204A............... Economizer (Horizontal)1236................................................. 85.......................... 2-5 1½-5 1½-5 BAYECONCOMB101B.... BAYECON101A, door, and filter kit............................................................................ 2-3 1½-3 1½-3 BAYECONCOMB102B.... BAYECON102A, door, and filter kit............................................................................ 3½-5 3½-5 3½-5 BAYENTH001A............... Enthalpy Control Kit2 .................................................................. 2........................... ✔ ✔ ✔ BAYEXMK001A............... Extreme Conditions Mounting Kit (Used on BAYCURB & BAYADAP)............................................................................. ✔ ✔ ✔ BAYEXMK002B............... Extreme Conditions Mounting Kit (Used on BAYUTIL).............................................. ✔ ✔ ✔ BAYEXMK003A............... Extreme Conditions Mounting Kit (Used on Slab Mounts)......................................... ✔ ✔ ✔ BAYFLTR101C................ 1-2" Filter Frame (requires one 20x25 filter which is not included)1 ............................................................................. 6........................... 2-3 1½-3 1½-3 BAYFLTR201C................ 1-2" Filter Frame (requires one 20x20 and one 20x18 filter which are not included)1 ..................................................... 6........................... 3½-5 3½-5 3½-5 BAYLIFT002B.................. Lifting Lug Kit ................................................................................ 5........................... ✔ ✔ ✔ BAYLOAM011A............... Evaporator Defrost Control Kit................................................................................... ✔ ✔ ✔ BAYLOAM105A............... Low Ambient Control Kit................................................................ 5........................... ✔ ✔ ✔ BAYOSAH001A............... Manual Fresh Air Damper1 ......................................................... 6........................... 2-3 1½-3 1½-3 BAYOSAH002A............... Manual Fresh Air Damper1 ......................................................... 8........................... 3½-5 3½-5 3½-5 BAYQSTK300A............... Start Kit ..................................................................................................................... 1 Phase Only 1 Phase Only 1 Phase Only BAYSQRD001A............... 16" Round Duct Adapter0............................................................ 5........................... 2-3 1½-3 1½-3 BAYSQRD002A............... 18" Round Duct Adapter0............................................................ 3........................... 2-5 1½-5 1½-5 BAYUTIL101B................. Roof Curb Utility Extension Kit................................................................................... 2-3 1½-3 1½-3 BAYUTIL102B................. Roof Curb Utility Extension Kit................................................................................... 3½-5 3½-5 3½-5 BAYUV101A.................... 21" Retrofit UVC Lamp Kit............................................................. 5........................... 1½-3 1½-3 1½-3 BAYUV102A.................... 33" Retrofit UVC Lamp Kit............................................................. 5........................... 3½-5 3½-5 3½-5 1Must use filter frame when economizer/fresh air kit is used. 2Dry bulb control standard with economizer. EXISTING NEW UNIT USE 32-Stage cooling control required when using economizer. CURB 4TC/WC/YC****A BAYADAP0**A 4Do not use with electronic thermostats. BAYCURB030,38A 018-036 50 5BAYCOVR112,118A will not cover BAYSQRD002A applications. 6Does not contain barometric relief. BAYCURB030,38A 042-060 52 7Max fresh air - 25%. BAYCURB033A 018-036 51 8For non-continuous fan gas-heating applications, the damper opens only when the OD BAYCURB033A 018-060 53 ambient is above 50° F. 9It is the designer/engineer's responsibility to review product specifications prior to BAYCURB034A 042-060 54 equipment selection to insure optimal performance and compliance to codes. 0Temperature of mixed air entering the heat exchanger is monitored and fresh air intake may be reduced under certain conditions. qBAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward compatible to BAYFLTR101/201A. For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-3 Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 1½-5 Tons Table PC-4-A — Supplementary Heaters – Separate power source /power entry required Model Number Description Used With BAYHTRV105E BAYHTRV108E BAYHTRV110E BAYHTRV115E BAYHTRV120E BAYHTRV125E BAYHTRV305E BAYHTRV308E BAYHTRV310E BAYHTRV315E BAYHTRV320E BAYHTRV325E BAYHTRV405E BAYHTRV408E BAYHTRV410E BAYHTRV415E BAYHTRV420E BAYHTRV425E 3.76/5.0 kW Heater (208/240V 1PH) 6.0/8.0 kW Heater (208/240V 1PH) 7.50/10.0 kW Heater (208/240V 1PH) 11.27/15.00 kW Heater (208/240V 1PH) 15.00/20.0 kW Heater (208/240V 1PH) 18.78/25.0 kW Heater (208/240V 1PH) 3.76/5.0 kW Heater (208/240V 3PH) 6.0/8.0 kW Heater (208/240V 3PH) 7.50/10.0 kW Heater (208/240V 3PH) 11.27/15.00 kW Heater (208/240V 3PH) 15.0/20.0 kW Heater (208/240V 3PH) 18.78/25.0 kW Heater (208/240V 3PH) 5.0 kW Heater (480V 3PH) 8.0 kW Heater (480V 3PH) 10.0 kW Heater (480V 3PH) 15.00 kW Heater (480V 3PH) 20.0 kW Heater (480V 3PH) 25.0 kW Heater (480V 3PH) Shipping Weight 4TC*3018-060A1,4024-06019 4TC*3018-060A1,4024-060110 4TC*3024-060A1,4024-060110 4TC*3030-060A1,4036-060114 4TC*3048-060A1,4048-060114 4TC*3060A1,4048-060121 4TC*3018-060A3,4036-060A3 9 4TC*3018-060A3,4036-060A3 10 4TC*3024-060A3,4036-060A3 10 4TC*3030-060A3,4036-060A3 14 4TC*3048-060A3,4048-060A3 14 4TC*3060A3,4048-060A3 20 4TC*3018-060A4 9 4TC*3018-060A4 10 4TC*3024-060A4 10 4TC*3030-060A4 14 4TC*3048-060A4 14 4TC*3060A4 16 Table PC-4-B — Single Power Entry Kit/Heater Matrix: Single Power Heater Entry Kit1Model Unit Model Shipping Weight BAYSPEK060E BAYSPEK061E BAYSPEK062E BAYSPEK063E BAYHTRV105E BAYHTRV108E BAYHTRV110E BAYHTRV305E BAYHTRV308E BAYHTRV310E BAYHTRV315E BAYHTRV405E BAYHTRV408E BAYHTRV410E BAYHTRV415E BAYHTRV420E BAYHTRV105E BAYHTRV108E BAYHTRV110E BAYHTRV115E BAYHTRV120E 4TC*3018-048A1,4TCY4024-04813 4TC*3018-048A1,4TCY4024-0601 4TC*3024-036A1,4TCY4024-0361 4TC*3036-060A3,4TCY4036-060A3 7 4TC*3036-060A3,4TCY4036-060A3 4TC*3036-048A3,4TCY4036-048A3 4TC*3036-060A3,4TCY4036-048A3 4TC*3036-060A4 4TC*3036-060A4 4TC*3036-060A4 4TC*3036-060A4 4TC*3048-060A4 4TC*306017 4TC*30601 4TC*30601,4TCY4036-0601 4TC*3030-060A1,4TCY4036-06017 4TC*3048-060A1,4TCY4048-0601 BAYSPEK064E BAYHTRV320E 4TC*3048-060A3,4TCY4048-060A3 6 1All necessary fuses are included in kit; however, not all kits require fuses. Please refer to BAYSPEK Installers Guide. Note: Replace "*" with "C" or "X" as appropriate. For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-4 Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 3-10 Tons Standard Features: Beveled Top Smoother Design Small compact cabinet Recessed access handles • American Standard Heating & Air Conditioning scroll compressors on all 3-10 ton units • Colored and numbered wiring • Phase Monitor, R-410A 3 Phase Units • Provisions for through the Base Condensate Drain Connections • 2" throwaway filters provided on all ton units • Liquid Line Refrigerant Drier • Operating Charge of R-410A • IAQ Sloped Drain Pans • Single point power for Electric Heat • Low Ambient to 40°F on Electromechanical models • Low Ambient to 0°F on ReliaTel™ models • 5 - year Limited Compressor Warranty • 1 - year Limited Parts Warranty Added Flexibility • Electromechanical or ReliaTel™ controls (See page PC-16 for ReliaTel™ Control Information) • Standard or high efficiency cooling models available. 17+ available in 3T to 5T. For reference to 17+ please refer to publications RT-PRC048-EN and RT-SLB020-EN • Convertible airflow (ships in downflow application) • Fork lift openings on three sides of unit • Direct or belt drive - standard or oversized motors (Direct for 3-5 ton only) • We don’t prepackage options • Choose options tailored to suit each job —pay only for what is needed • Units ship with options installed —and within our standard ship cycle time Factory Installed Options • Through-the-Base — Electrical • Convenience Outlet — Powered or unpowered • Unit Disconnect Switch • Smoke Detectors — Supply, return, or both • Condenser Coil Coating • Hinged Access Service Panels • Discharge Air Sensor • Fan Fail and Clogged Filter Switches • Condenser Coil Guard — Hail Protection Quality • Dehumidification Hot Gas Reheat Coil • Frostat • Novar Controls • Comm 3/4 Communications Interface • 2" Pleated Media filters • 2" MERV 8 filters or 2" MERV 13 filters • Multi-Speed & Single Zone VAV ID Airflow The same American Standard Heating & Air Conditioning Quality and Reliability … with added Flexibility! For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-5 Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 3-5 Tons, R-410A Table PC-6-A — Base Unit — 15 SEER High Efficiency — R-410A — Electromechanical or ReliaTel™ Unit Performance2 Tons Ordering No. SEER/EER Cooling Cabinet Shipping Capacity Dimensions (in.) Downflow Downflow Weight (Btuh) H x W x L Supply Return (Ibs.) MCA** THC – 208-230/1/60 – Single Phase – No Heat 3 THC036E1*0A0000 15.2 38,490 4 THC048E1*0A0000 15.0 48,930 5 THC060E1*0A0000 15.0 62,480 THC – 208/3/60 – Three Phase – No Heat 3 THC036E3*0A0000 15.0 38,490 4 THC048E3*0A0000 15.0 49,930 5 THC060E3*0A0000 15.0 63,490 THC – 460/3/60 – Three Phase – No Heat 3 THC036E4*0A0000 15.0 38,490 4 THC048E4*0A0000 15.0 49,830 5 THC060E4*0A0000 15.0 63,480 Max1 Fuse** 36 x 44 x 69 41 x 53 x 88 41 x 53 x 88 16 x 15.5 33 x 17.5 33 x 17.5 24 x 14 55526.740 32.2 x 17.5798 35.7 50 32.2 x 17.5823 43.8 70 36 x 44 x 69 41 x 53 x 88 41 x 53 x 88 16 x 15.5 33 x 17.5 33 x 17.5 24 x 14 55521.930 32.2 x 17.5637 28.3 40 32.2 x 17.5869 32.1 45 36 x 44 x 69 41 x 53 x 88 41 x 53 x 88 16 x 15.5 33 x 17.5 33 x 17.5 24 x 14 55510.215 32.2 x 17.5637 13.8 20 32.2 x 17.5869 17.0 25 Table PC-6-B — Base Unit — Standard Efficiency — R-410A — Electromechanical or ReliaTel™ Unit Performance Tons Ordering No. SEER/EER Cooling Cabinet Shipping Capacity Dimensions (in.) Downflow Downflow Weight (Btuh) H x W x L Supply Return (Ibs.) MCA** Max Fuse** TSC – 208-230/1/60 – Single Phase – No Heat 3 TSC036E1*0A0000 13.0 35,620 36 x 43 x 69 16 x 15.5 24 x 14 555 27.2 40 4 TSC048E1*0A0000 13.0 49,210 36 x 43 x 69 16 x 15.5 24 x 14 586 35.2 50 5 TSC060E1*0A0000 13.0 59,900 36 x 43 x 69 16 x 15.5 24 x 14 636 43.8 70 TSC – 208-230/3/60 – Three Phase – No Heat 3 TSC036E3*0A0000 13.0 37,150 36 x 43 x 69 16 x 15.5 24 x 14 555 23.0 35 4 TSC048E3*0A0000 13.0 49,450 36 x 43 x 69 16 x 15.5 24 x 14 586 25.2 35 5 TSC060E3*0A0000 13.0 62,270 36 x 43 x 69 16 x 15.5 24 x 14 636 29.5 45 TSC – 460/3/60 – Three Phase – No Heat 3 TSC036E4*0A0000 13.0 37,150 36 x 43 x 69 16 x 15.5 24 x 14 555 11.7 15 4 TSC048E4*0A0000 13.0 49,450 36 x 43 x 69 16 x 15.5 24 x 14 586 12.5 15 5 TSC060E4*0A0000 13.0 62,270 36 x 43 x 69 16 x 15.5 24 x 14 636 15.5 25 TSC – 575/3/60 – Three Phase – No Heat 3 TSC036EW*0A0000 13.0 37,150 36 x 43 x 69 16 x 15.5 24 x 14 555 9.4 15 4 TSC048EW*0A0000 13.0 49,450 36 x 43 x 69 16 x 15.5 24 x 14 586 9.0 15 5 TSC060EW*0A0000 13.0 62,270 36 x 43 x 69 16 x 15.5 24 x 14 636 10.1 15 Table PC-6-C — 17 Plus - R-410A - ReliaTel™ Controls Only Unit Performance Tons Ordering No. SEER/EER Cooling Cabinet Shipping Capacity Dimensions (in.) Downflow Downflow Weight (Btuh) H x W x L Supply Return (Ibs.) MCA** Max Fuse** THC - 208-230/3/60 - Three Phase - No Heat 3 THC037E3R0A0000 17.5 36,500 36 x 44 x 69 18 x 15.5 24 x 14 614 23.3 30 4 THC047E3R0A0000 17.5 50,500 41 x 53 x 88 33 x 17.5 33 x 17.5 787 29.4 40 5 THC067E3R0A0000 17.2 60,000 41 x 53 x 88 33 x 17.5 33 x 17.5 841 32.2 45 THC - 460/3/60 - Three Phase - No Heat 3 THC037E4R0A0000 17.5 36,500 36 x 44 x 69 18 x 15.5 24 x 14 614 11.4 15 4 THC047E4R0A0000 17.5 50,500 41 x 53 x 88 33 x 17.5 33 x 17.5 787 13.7 20 5 THC067E4R0A0000 17.2 60,000 41 x 53 x 88 33 x 17.5 33 x 17.5 841 15.2 20 1 HACR breaker per NEC. 2 SEER applies, 3-5 tons; EER applies 6-10 tons. * Digit 9 - E = Electromechanical or R = ReliaTel™. ** Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-6 Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 6 - 10 Tons, R-410A Table PC-7-A — Base Unit — High Efficiency — R-410A — Electromechanical or ReliaTel™ Unit Performance Tons Ordering No. EER Cooling Cabinet Capacity Dimensions (in.) Downflow Downflow (Btuh) H x W x L Supply Return THC – 208-230/3/60 – Three Phase High Efficiency 6 THC072E3*0A0000 12.6 72,000 7½ THC092F3*0A0000 12.6 92,000 8½ THC102E3*0A0000 13.0 103,000 10 THC120E3*0A0000 12.5 119,000 THC – 460/3/60 – Three Phase 6 THC072E4*0A0000 12.6 72,000 7½ THC092F4*0A0000 12.6 92,000 8½ THC102E4*0A0000 13.0 103,000 10 THC120E4*0A0000 12.5 119,000 Shipping Weight Max1 (Ibs.) MCA** Fuse** 47 x 53 x 88 47 x 53 x 88 51 x 63 x 100 51 x 63 x 100 33 x 17.5 33 x 17.5 32.25 x 19.25 32.25 x 19.25 32.13 x 17.5 997 32.13 x 17.5 1026 32.25 x 16.75 1553 32.25 x 16.75 1563 33.9 41.9 44.7 50.3 50 50 60 60 47 x 53 x 88 47 x 53 x 88 51 x 63 x 100 51 x 63 x 100 33 x 17.5 33 x 17.5 32.25 x 19.25 32.25 x 19.25 32.13 x 17.5 997 32.13 x 17.5 1026 32.25 x 16.75 1553 32.25 x 16.75 1563 16.3 19.9 22.9 24.9 25 25 30 30 Table PC-7-B — Base Unit — Standard Efficiency — R-410A — Electromechanical or ReliaTel™ Unit Performance Tons Ordering No. SEER/EER Cooling Cabinet Shipping Capacity Dimensions (in.) Downflow Downflow Weight (Btuh) H x W x L Supply Return (Ibs.) MCA** Max Fuse** TSC – 208-230/3/60 – Three Phase – No Heat 6 TSC072E3*0A0000 11.2 75,000 42 x 53 x 88 33 x 17.5 32.13 x 17.5 898 36.5 50 71/2 TSC090E3*0A0000 11.2 89,000 42 x 53 x 88 33 x 17.5 32.13 x 17.5 815 38.2 60 71/2 TSC092E3*0A0000 11.2 94,000 46 x 53 x 88 33 x 17.5 32.13 x 17.5 1009 41.2 50 81/2 TSC102E3*0A0000 11.2 102,000 46 x 53 x 88 33 x 17.5 32.13 x 17.5 1048 46.3 60 10 TSC120F3*0A0000 11.3 119,000 46 x 53 x 88 33 x 17.5 32.13 x 17.5 1058 49.6 60 TSC – 460/3/60 – Three Phase – No Heat 6 TSC072E4*0A0000 11.2 75,000 42 x 53 x 88 33 x 17.5 32.13 x 17.5 898 18.2 25 71/2 TSC090E4*0A0000 11.2 89,000 42 x 53 x 88 33 x 17.5 32.13 x 17.5 815 19.5 30 71/2 TSC092E4*0A0000 11.2 94,000 46 x 53 x 88 33 x 17.5 32.13 x 17.5 1009 21.5 25 81/2 TSC102E4*0A0000 11.2 102,000 46 x 53 x 88 33 x 17.5 32.13 x 17.5 1048 21.9 25 10 TSC120F4*0A0000 11.3 119,000 46 x 53 x 88 33 x 17.5 32.13 x 17.5 1058 22.7 35 TSC – 575/3/60 – Three Phase – No Heat 6 TSC072EW*0A0000 11.2 75,000 42 x 53 x 88 33 x 17.5 32.13 x 17.5 898 12.7 20 71/2 TSC090EW*0A0000 11.2 89,000 42 x 53 x 88 33 x 17.5 32.13 x 17.5 815 14.7 20 71/2 TSC092EW*0A0000 11.2 94,000 46 x 53 x 88 33 x 17.5 32.13 x 17.5 1009 15.0 20 81/2 TSC102EW*0A0000 11.2 102,000 46 x 53 x 88 33 x 17.5 32.13 x 17.5 1048 17.5 20 10 TSC120FW*0A0000 11.3 119,000 46 x 53 x 88 33 x 17.5 32.13 x 17.5 1058 18.9 25 1HACR breaker per NEC. * Digit 9-E=Electromechanical or R=ReliaTel™. ** Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-7 Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 3-10 Tons (Model Digit Numbers) Digit Description Digit Order Number 1 Enthalpy control not available factory installed with electro-mechanical controls. 2 Economizer with Barometric Relief is for downfllow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must be ordered as field installed accessory BAYBARM010A. 3 Requires use of Disconnect or Circuit Breaker. 4 Frostat cannot be field installed in electro-mechanical units. 5 Not available with BAYFRST001A High Temperature Stat accessory. 6 The return air smoke detector may not fit up or work properly on the Convertible units when used in conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not order the return air smoke detectors when using this type of accessory. Heaters (Digit 10) kW Nominal No. Rating Digit BTUH Stages Used With 208/240/1/60 3.7/5.0 7.5/10.0 10.3/13.8 13.2/17.6 208/240/3/60 4.5/6.0 9.0/12.0 13.2/17.6 17.2/23.0 6.75/9.0 13.5/18.0 20.3/27.0 27.0/36.0 40.5/54.0 (A) (D) (F) (G) 12,800/17,100 25,600/34,100 35,300/47,100 45,100/60,100 1 2 2 2 T*C036-060*1 T*C036-060*1 T*C036-060*1 T*C048-060*1 (B) (E) (G) (J) (C) (G) (K) (N) (P) 13,400/20,500 30,800/59,400 44,600/59,400 58,900/78,500 23,000/30,700 46,100/61,400 69,000/92,100 92,200/122,900 138,200/184,300 1 2 2 2 1 1 2 2 2 T*C036-060*3 T*C036-060*3 T*C036-060*3 T*C060*3 T*C072-102*3 T*C072-120*3 T*C072-120*3 T*C072-120*3 T*C120*3 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. Description Order Number 18 Through the Base Provisions No Through the Base Provisions................................... 0 Through the Base Electricq......................................... A 19 Disconnect/Circuit Breaker /Phase Monitor (3 phase only) No Disconnect/ Circuit Breaker..................................... 0 Unit Mounted Non-Fused Disconnectq........................ 1 Unit Mounted Circuit Breakerq..................................... 2 20 Convenience Outlet No Convenience Outlet................................................. 0 Unpowered Convenience Outlet.................................... A Powered Convenience Outlet (3 phase only)3 ............ B 21 Communications Optionsw No Communications Interface....................................... 0 Comm 3/4 Communications Interface........................... 1 Novar 2024 Controls..................................................... 3 Novar 3051 Controls..................................................... 4 22 Refrigeration System Option Standard Refrigeration System..................................... 0 Dehumidification (Hot Gas Reheat Coil)........................ B 23 Refrigeration Controls No Refrigeration Control .............................................. 0 Frostat4........................................................................ 2 24 Smoke Detector5w No Smoke Detector....................................................... 0 Return Air Smoke Detector67.................................... A Supply Air Smoke Detector........................................... B Supply and Return Air Smoke Detectors67................ C 25 Monitoring Controlsw No Monitoring Control8 ............................................... 0 Clogged Filter Switch8 ................................................ 1 Fan Failure Switch8..................................................... 2 Discharge Air Sensing Tube8....................................... 3 Clogged Filter Switch and Fan Fail Switch8................. 4 Clogged Filter Switch and Discharge Air Sensing Tube8..................................................... 5 Fan Fail Switch and Discharge Air Sensing Tube8....... 6 Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tube8............................. 7 Novar Return Air Sensor9............................................ 8 Novar 3051 Zone Sensore........................................... 9 1-8 Main Assembly (see previous page) 9 Unit Controls Electro-Mechanical ....................................................... E ReliaTel™ Micro-processor........................................... R 10 (See Heater Table below) 11 Minor Design Sequence First Sequence............................................................. A 12-13 Service Sequence First Sequence (Factory Supplied).............................. ✱,✱ 14 Fresh Air Selection No Fresh Air.................................................................. 0 0-50% Manual Outside Air Damper0........................... A 0-50% Motorized Outside Air Damper........................... B 0-100% Economizer, Dry Bulb without Barometric Relief 2 .................................................. C 0-100% Economizer, Dry Bulb with Barometric Relief2 ................................................. D 0-100% Economizer, Reference Enthalpy without Barometric Relief12 ................................... E 0-100%Economizer, Reference Enthalpy with Barometric Relief12 ....................................... F 0-100%Economizer, Comparative Enthalpy without Barometric Relief 12 ............................ G 0-100%Economizer, Comparative Enthalpy with Barometric Relief 12 ...................................... H 15 Supply Fan/Drive Type/Motor Standard Drive.............................................................. 0 Oversized Motor............................................................ 1 Optional Belt Drive Motor (3 phase only)...................... 2 16 Hinged Service Access & Filters Standard Panels & Filters.............................................. 0 Hinged Access Panels & Standard Filters..................... A Standard Panels & 2" Pleated Filters MERV 7.............. B Hinged Access Panels & 2" Pleated Filters MERV 7..... C Standard Panels/2" MERV 13 Filters............................. D High Access Panels/2" MERV 13 Filters....................... E 17 Condenser Coil Protection Standard Coil ............................................................... 0 Standard Coil with Hail Guard....................................... 1 Black Epoxy Pre-Coated Condenser Coil...................... 2 Black Epoxy Pre-Coated Condenser Coil with Hail Guard.......................................................... 3 Complete Coat™ Condenser Coil................................. 4 Complete Coat™ Condenser Coil with Hail Guard........ 5 7 Return Air Smoke Detector cannot be ordered with Novar Controls. 8 These options are standard when ordering Novar Controls. 9 This options for use when ordering Novar Control only. 0 The manual outside air damper will ship factory supplied within the unit, but must be field installed. q Through the base electric required when ordering disconnect/circuit breaker options. w Not available with electro-mechanical unit controls. e Novar Sensor utilized with digit 21 = (4) Novar 3051 Controls without Zone Sensor. kW Nominal No. Rating Digit BTUH Stages Used With 460/3/60 6.0 12.0 17.6 23.0 9.0 18.0 27.0 36.0 54.0 575/3/60 6.0 12.0 17.6 23.0 9.0 18.0 27.0 36.0 54.0 PC-8 (B) (E) (G) (J) (C) (G) (K) (N) (P) 20,500 41,000 59,400 78,500 30,700 61,400 92,100 122,900 184,300 1 2 2 2 1 1 2 2 2 T*C036-060*4 T*C036-060*4 T*C036-060*4 T*C060*4 T*C072-102,*4 T*C072-120*4 T*C072-120*4 T*C072-120*4 T*C120*4 (B) (E) (G) (J) (C) (G) (K) (N) (P) 20,500 41,000 59,400 78,500 30,700 61,400 92,100 122,900 184,300 1 2 2 2 1 1 2 2 2 T*C036-060*W T*C036-060*W T*C036-060*W T*C060*W T*C072-102*W T*C072-120*W T*C072-120*W T*C072-120*W T*C120*W Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 3-10 Tons, R-410A Electric Heaters Table PC-9-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entry Model Number Power Supply kW Rating Nominal BTUH No. Stages BAYHTRE105A BAYHTRE110A BAYHTRE114A BAYHTRE118A 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 3.8/5.0 7.5/10.0 10.4/13.8 13.2/17.6 12,900/13,400 25,600/34,000 35,000/47,100 45,100/60,100 1 2 2 2 Used With T*C036E1,TSC048-060E1 T*C036E1,TSC048-060E1 T*C036E1,TSC048-060E1 TSC048-060E1 BAYHTRE306B BAYHTRE312B BAYHTRE318B BAYHTRE323B 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 4.5/6.0 9.0/12.0 13.0/17.4 17.3/23.0 13,400/20,500 30,800/41,000 44,600/59,400 44,600/59,400 1 2 2 2 T*C036E3,TSC048-060E3, THC037E3 T*C036E3,TSC048-060E3, THC037E3 T*C036E3,TSC048-060E3, THC037E3 TSC060E3 BAYHTRE406B 460/3/60 6.0 20,500 1 T*C036E4,TSC048-060E4, THC037E4 BAYHTRE412B 460/3/60 12.0 41,000 2 T*C036E4,TSC048-060E4, THC037E4 BAYHTRE418B 460/3/60 17.4 59,400 2 T*C036E4,TSC048-060E4, THC037E4 BAYHTRE423B 460/3/60 17.3/23.0 59,400 2 TSC060E4 BAYHTREW06B 575/3/60 6.0 20,500 1 T*C036EW,TSC048-060EW BAYHTREW12B 575/3/60 12.0 41,000 2 T*C036EW,TSC048-060EW BAYHTREW18B 575/3/60 17.4 59,400 2 T*C036EW,TSC048-060EW BAYHTREW23B 575/3/60 17.3/23.0 59,400 2 TSC060EW BAYHTRX105A BAYHTRX110A BAYHTRX114A BAYHTRX118A 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 3.8/5.0 7.5/10.0 10.4/13.8 13.2/17.6 12,900/13,400 25,600/34,000 35,000/47,100 45,100/60,100 1 2 2 2 THC048-060E1 THC048-060E1 THC048-060E1 THC048-060E1 BAYHTRX306B BAYHTRX312B BAYHTRX318B BAYHTRX323B 208-230/1/60 208-230/3/60 208-230/3/60 208-230/3/60 4.5/6.0 9.0/12.0 13.0/17.4 17.3/23.0 13,400/20,500 30,800/41,000 44,600/59,400 59,000/78,500 1 2 2 2 THC048-060E3, THC047E3, THC067E3 THC048-060E3, THC047E3, THC067E3 THC048-060E3, THC047E3, THC067E3 THC060E3 BAYHTRX406B BAYHTRX412B BAYHTRX418B BAYHTRX423B 460/3/60 460/3/60 460/3/60 460/3/60 6.0 12.0 18.0 23.0 20,500 41,000 59,400 78,500 1 2 2 2 THC048-060E4, THC047E4, THC067E4 THC048-060E4, THC047E4, THC067E4 THC048-060E4, THC047E4, THC067E4 THC060E4, THC067E4 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-9 Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 6-10 Tons, R-410A Electric Heaters Table PC-10-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entry Model Number Power Supply kW Rating Nominal BTUH No. Stages Used With BAYHTRS309B BAYHTRS318B BAYHTRS327B BAYHTRS336B 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 6.75/9.0 13.5/18.0 20.3/27.0 27.0/36.0 23,000/30,700 46,100/61,400 69,000/92,100 92,200/122,900 1 2 2 2 TSC072E3 TSC072E3 TSC072E3 TSC072E3 BAYHTRW309A BAYHTRW318A BAYHTRW327A BAYHTRW336A 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 6.75/9.0 13.5/18.0 20.3/27.0 27.0/36.0 23,000/30,700 46,100/61,400 69,000/92,100 92,200/122,900 1 1 2 2 TSC090E3 TSC090E3 TSC090E3 TSC090E3 BAYHTRT309B BAYHTRT318B BAYHTRT327B BAYHTRT336B 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 6.75/9.0 13.5/18.0 20.3/27.0 27.0/36.0 23,000/30,700 46,100/61,400 69,000/92,100 92,200/122,900 1 2 2 2 TSC092E3, TSC102E3 TSC092E3, TSC102E3 TSC092E3, TSC102E3 TSC092E3, TSC102E3 BAYHTRA318A BAYHTRA327A BAYHTRA336A BAYHTRA354A 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 13.5/18 20.3/27 27/36 40.5/54 46,100/61,400 69,000/92,100 92,200/122,900 138,200/184,300 1 2 2 2 TSC120F3 TSC120F3 TSC120F3 TSC120F3 BAYHTRS409B BAYHTRS418B BAYHTRS427B BAYHTRS436B 460/3/60 460/3/60 460/3/60 460/3/60 9.0 18.0 27.0 36.0 30,700 61,400 92,100 122,900 1 2 2 2 TSC072E4 TSC072E4 TSC072E4 TSC072E4 BAYHTRW409A 460/3/60 9 30,700 BAYHTRW418A 460/3/60 18 61,400 BAYHTRW427A 460/3/60 27 92,100 BAYHTRW436A 460/3/60 36 122,900 BAYHTRT409B 460/3/60 9.0 30,700 BAYHTRT418B 460/3/60 18.0 61,400 BAYHTRT427B 460/3/60 27.0 92,100 BAYHTRT436B 460/3/60 36.0 122,900 1 1 2 2 TSC090E4 TSC090E4 TSC090E4 TSC090E4 1 2 2 2 TSC092E4, TSC102E4 TSC092E4, TSC102E4 TSC092E4, TSC102E4 TSC092E4, TSC102E4 BAYHTRA418A BAYHTRA427A BAYHTRA436A BAYHTRA454A 1 2 2 2 TSC120F4**B TSC120F4**B TSC120F4**B TSC120F4**B 460/3/60 460/3/60 460/3/60 460/3/60 18 27 36 54 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. 61,400 92,100 122,900 184,300 PC-10 Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 6-10 Tons, R-410A Electric Heaters Table PC-11-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entry Model Number BAYHTRSW09B BAYHTRSW18B BAYHTRSW27B BAYHTRSW36B Power Supply 575/3/60 575/3/60 575/3/60 575/3/60 kW Rating 9.0 18.0 27.0 36.0 Nominal BTUH Used With 1 2 2 2 TSC072EW TSC072EW TSC072EW TSC072EW BAYHTRWW18A 575/3/60 18 61,400 BAYHTRWW27A 575/3/60 27 92,100 BAYHTRWW36A 575/3/60 36 122,900 BAYHTRTW18B 575/3/60 18.0 61,400 BAYHTRTW27B 575/3/60 27.0 92,100 BAYHTRTW36B 575/3/60 36.0 122,900 1 2 2 TSC090EW TSC090EW TSC090EW 2 2 2 TSC092EW, TSC102EW TSC092EW, TSC102EW TSC092EW, TSC102EW BAYHTRAW18A BAYHTRAW36A BAYHTRAW54A 575/3/60 575/3/60 575/3/60 18 36 54 61,400 122,900 184,300 1 2 2 TSC120FW TSC120FW TSC120FW BAYHTRU309A BAYHTRU318A BAYHTRU327A BAYHTRU336A 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 6.8/9.0 13.5/18.0 20.3/27.0 27.0/36.0 23,000/30,700 46,100/61,400 69,000/92,100 92,100/122,900 1 1 2 2 THC072E3 THC072E3 THC072E3 THC072E3 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. 30,700 61,400 92,100 122,900 No. Stages PC-11 Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 6-10 Tons, High Efficiency R-410A Electric Heaters Table PC-12-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entry Model Number Power Supply kW Rating Nominal BTUH BAYHTRA309A 208-230/3/60 9.0 30,700 BAYHTRA318A 208-230/3/60 18.0 61,400 BAYHTRA327A 208-230/3/60 27.0 92,100 BAYHTRA336A 208-230/3/60 36.0 122,900 BAYHTRA409A 460/3/60 9.0 30,700 BAYHTRA418A 460/3/60 18.0 61,400 BAYHTRA427A 460/3/60 27.0 92,100 BAYHTRA436A 460/3/60 36.0 122,900 No. Stages Used With 1THC092F3 1THC092F3 2THC092F3 2THC092F3 1THC092F4 1THC092F4 2THC092F4 2THC092F4 BAYHTRD309A 208-230/3/60 6.8/9.0 23,000/30,700 1THC102E3 BAYHTRD318A 208-230/3/6013.5/18.0 46,100/61,400 1THC102E3,THC120E3 BAYHTRD327A 208-230/3/6020.3/27.0 69,000/92,100 2THC102E3,THC120E3 BAYHTRD336A 208-230/3/6027.0/36.092,100/122,900 2THC102E3,THC120E3 BAYHTRD354A 208-230/3/60 40.6/54.0138,000/184,3002 THC120E3 BAYHTRU409A 460/3/60 9.0 30,700 1 THC072E4 BAYHTRU418A 460/3/60 18.0 61,400 1 THC072E4 BAYHTRU427A 460/3/60 27.0 92,100 2 THC072E4 BAYHTRU436A 460/3/60 36.0 122,900 2 THC072E4 BAYHTRD409A BAYHTRD418A BAYHTRD427A BAYHTRD436A BAYHTRD454A 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 9.0 18.0 27.0 36.0 54.0 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. 30,700 61,400 92,100 122,900 184,300 PC-12 1THC102E4 1THC102E4,THC120E4 2THC102E4,THC120E4 2THC102E4,THC120E4 2THC120E4 Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 3-10 Tons Accessories Table PC-13-A — Accessories Model Number Description Used With BAYABRD001C........... ReliaTel™ Options Module................................................... All T*036-120E (ReliaTel™) See Note5 BAYASCT00167* ...... Anti-Short-Cycle Timer......................................................... All T*036-120E (Electro Mechanical) BAYBARM010A4 ....... Barometric Relief................................................................. THC036-060E, THC036E BAYBARM011A4 ....... Barometric Relief................................................................. TSC072-102E, THC092F, TSC120F, THC048E-120E BAYBCIR001A............. Bacnet™ Communication Interface..................................... ReliaTel™ Controller (BCI-R) BAYCCHT010B........... Crankcase Heater................................................................ TSC036-048E1, 3 BAYCCHT011B........... Crankcase Heater................................................................ TSC036-048E4, W BAYCCHT017A........... Crankcase Heater................................................................ TSC060E1, 3 BAYCCHT018A........... Crankcase Heater................................................................ TSC060E4, EW ASYSTAT712B38 ..... CO2 Sensor Kit, Wall Mounted............................................. All T*036-120E (ReliaTel™) ASYSTAT714B38 ..... CO2 Sensor Kit, Duct Mounted............................................. All T*036-120E (ReliaTel™) BAYCURB042A2........ Roof Curb............................................................................. THC036E, TSC036E-060E BAYCURB043A2........ Roof Curb............................................................................. THC048E-072E, TSC072-102E, THC092F, TSC120F BAYCURB044A........... Roof Curb............................................................................. THC102E-120E BAYDFPS003B35 ..... Clogged Filter Switch........................................................... All T*036-120E (ReliaTel™) BAYDFPS004A35 ..... Fan Failure Switch................................................................ All T*036-120E (ReliaTel™) BAYDFPS014A ........... Clogged Filter Switch (w/MERV 13 Filter)............................ All T*036-120E (ReliaTel™) BAYDMPR053B9 ....... 0-50% Manual Outside Air Damper..................................... THC036E, TSC036E-060E BAYDMPR056B9 ....... 0-50% Manual Outside Air Damper..................................... THC048E-120E, TSC072-102E, TSC120F BAYDMPR051A3 ....... 0-50% Motorized Outside Air Damper................................. THC036E_R, TSC036-060E_R (ReliaTel™) BAYDMPR052A6 ....... 0-50% Motorized Outside Air Damper................................. THC036E_E, TSC036E-060E_E (Electro Mechanical) BAYDMPR054A3 ....... 0-50% Motorized Outside Air Damper................................. THC048-120E_R, TSC072-120F_R (ReliaTel™) BAYDMPR055A6 ...... 0-50% Motorized Outside Air Damper................................. THC048-120E_E, TSC072-120F_E (Electro Mechanical) BAYECON085A3 ....... 0-100% Dry Bulb Economizer without Barometric Relief .... THC036E_R, TSC036E-060E_R (ReliaTel™) BAYECON086A6 ....... 0-100% Dry Bulb Economizer without Barometric Relief .... THC036E_E, TSC036E-060E_E (Electro Mechanical) BAYECON087A3 ....... 0-100% Dry Bulb Economizer without Barometric Relief .... THC048-120*_R, TSC072*-120_R (ReliaTel™) BAYECON088A6 ....... 0-100% Dry Bulb Economizer without Barometric Relief .... THC048-120*_E, TSC072*-120_E (Electro Mechanical) BAYENTH005A13 .... Reference Enthalpy Kit......................................................... BAYECON085A, 087A BAYENTH006B13 .... Comparative Enthalpy Kit..................................................... BAYECON085A, 087A BAYENTH001A........... Enthalpy Control (Solid State).............................................. BAYECON0086A, 088A BAYFRST003A36 ..... High Temperature Stat......................................................... All T*036-120E 1Kits contain all necessary parts to achieve desired level of enthalpy control. 2Lynn Haven Manufacturing has a No-Return policy for this roof curb. 3For use with ReliaTel™ controlled units only. 4Barometric Relief accessory installs in ductwork for horizontal configuration. For downflow configuration, installs in the unit's horizontal return duct. See Installer's Guide for complete instructions. 5BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit (BAYTUBE004A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) Ventilation Override Kit (BAYVNOR001B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options include the ReliaTel™ Options Module. 6For use with electromechanical controlled units only. 7Activated on Power On. 8Field installed accessory requires economizer. 9The manual outside air damper will ship factory supplied within the unit, but must be field installed. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-13 Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 3-10 Tons Accessories Table PC-14-A — Accessories Model Number Description Used With BAYGARD037B..................Condenser Coil Hail Guard....................................................TSC036-060E, THC036E BAYGARD040A..................Condenser Coil Hail Guard....................................................THC048-060E,TSC072E-090E BAYGARD041A..................Condenser Coil Hail Guard....................................................TSC092E, TSC102E, THC072E BAYGARD070A..................Condenser Coil Hail Guard....................................................THC102E, THC120E BAYGARD141A..................Condenser Coil Hail Guard....................................................TSC120F, THC092F BAYHSDR012A..................High Static Drive Kit...............................................................THC072E BAYHSMT082A..................2 HP Oversized Motor Kit (208-230/460V).............................TSC072E3, 4 BAYHSMT083A..................2 HP Oversized Motor Kit (575V)...........................................TSC072EW BAYHSMT086A..................3 HP Oversized Motor Kit (208-230/460V).............................TSC090E-102E3, 4 BAYHSMT087A..................3 HP Oversized Motor Kit (575V)...........................................TSC090E-102EW BAYHSMT402A..................2 HP Oversized Motor Kit.......................................................THC072E3, 4 BAYKSKT255B...................Start Kit..................................................................................TSC036E1-060E1 BAYLMSW001A0..............Power Exhaust Limit Switch...................................................All T*036-120E, R BAYLOAM020B134........Evaporator Defrost Control (Frostat)......................................All T*036-120E, R (ReliaTel™) BAYLSDR006B...................Low Static Drive Kit: 3-5T High Efficiency..............................THC036E-060E BAYLSDR009A...................Low Static Drive Kit................................................................TSC092-102E, THC072E BAYPWRX026A6..............Power Exhaust (208-230/3 VAC)............................................TSC072-102E3, TSC120F3, THC072E3, THC092F3, THC102E3, TCH120E3 BAYPWRX027A6..............Power Exhaust (460/3 VAC)...................................................TSC072-102E4, TSC120F4, THC072E4, THC092F4, THC102E4, TCH120E4 BAYPWRX028A6..............Power Exhaust (575/3 VAC)...................................................TSC072-102EW, TSC120FW BAYPWRX070A6..............Power Exhaust (208-230/3 VAC)............................................TSC036-060E3, TCH036-THC060E3, THC037E3, THC047E3, THC067E3 BAYPWRX071A6..............Power Exhaust (460/3 VAC)...................................................TSC036-060E4, TCH036-THC060E4, THC037E4, THC047E4, THC067E4 BAYPWRX072A6..............Power Exhaust (575/3 VAC)...................................................TSC036-060EW BAYQACB009A25...........Quick Adapt Roof Curb..........................................................TSC036-060E, THC036E, THC037E BAYQACB010A25...........Quick Adapt Roof Curb..........................................................TSC036-060E, THC036E, THC037E BAYQACB011A27...........Quick Adapt Roof Curb..........................................................TSC072-102E, TSC120F, THC048-072E, THC047E, THC067E BAYQACB012A27...........Quick Adapt Roof Curb..........................................................TSC072-102E, TSC120F, THC048-072E, THC047E, THC067E BAYQACB013A27...........Quick Adapt Roof Curb..........................................................TSC072-102E, TSC120F, THC048-072E, THC047E, THC067E BAYRTEM001Aq...............Fully Featured ReliaTel™ Economizer Logic Model...............All T*036-120E, R BAYSTAT0233 ..................Remote Potentiometer............................................................All T*036-120E, R BAYSERV001A3...............Selective Resistance Service Tester......................................All T*036-120E, R BAYSENS016A3...............Temperature Sensor...............................................................All T*036-120E, R BAYTUBE005A...................Discharge Air Sensing Kit.......................................................TSC036-060E*R, THC036-037E*R BAYTUBE007A...................Discharge Air Sensing Kit.......................................................TSC072-102E*R, THC047E-072E*R BAYTUBE401A...................Discharge Air Sensing Kit.......................................................TSC120F*R, THC092F*R BAYTUBE403A...................Discharge Air Sensing Kit.......................................................TSC102-120E*R BAYVNOR001B349 ......Ventilation Override Kit w/ReliaTel™ options module.............All T*036-120E, R 1For ReliaTel™ microprocessor controlled units only. Must be factory installed for electromechanical controlled units. 2Lynn Haven Manufacturing has a No-Return policy for this roof curb. 3For use with ReliaTel™ controlled units only. 4BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit (BAYTUBE004A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) Ventilation Override Kit (BAYVNOR001B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options include the ReliaTel™ Options Module. 5BAYQACB009A adapts YCD units BAYCURB021B to accept T*C3-5 ton unit. BAYQACB010A adapts YCD units BAYCURB022B to accept T*C unit. 6Cannot be used in conjunction with Barometric Relief. Order Economizer without Barometric Relief. 7BAYQACB012A adapts YCD units BAYCURB025A to accept T*C 6-10 ton unit. BAYQACB013A adapts YCD units BAYCURB026A to accept T*C 6-10 ton unit. 8Interface allows a unit with ReliaTel™ Controls to communicate with Tracer 100, Tracker, VariTrac II, and is the preferred method of communication to Tracer Summit. 9Field installed accessory requires economizer. 0When ordering a field installed power exhaust on a unit with electromechanical controls, BAYLMSW001A must be ordered. qIf any version of comparative or reference enthalpy is ordered, BAYRTEM001A does not need to be ordered. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-14 Effective 7/1/12 14-1011-28 Packaged Cooling Convertible 3-10 Tons, R-410A Zone Sensors / Thermostats Table PC-15-A — Zone Sensors for ReliaTel™ Controlled Units Model Number Description ASYSTAT106A ASYSTAT107A ASYSTAT108A ASYSTAT109A ASYSTAT111A ASYSTAT777A ASYSTAT708A ASYSTAT710A ASYSTAT711A BAYMTPL110A Used With Single Setpoint Manual Changeover Single Setpoint Dual Setpoint Manual or Auto Changeover Dual Setpoint Changeover Sensor Remote Room Sensor Programmable Night Setback w/System Function Lights (Vertical Style) Programmable Night Setback w/System Function Lights Wall Mounted Humidity Sensor Duct Mounted Humidity Sensor Retrofit Wall Cover Plate Kit 7.25" x 6.0" T*C036-120 (A or E)_R T*C036-120E, R T*C036-120 (A or E)_R T*C036-120E, R T*C036-120 (A or E)_R T*C036-120 (A or E)_R T*C036,120A,3,4,W-R,T*C036-120E_R T*C036-120A-B,T*C036-120E_R ASYSTAT111A *Either standard or high efficiency models. Table PC-15-B — Thermostats — Electromechanical Model Number Description Used With ASYSTAT712B ASYSTAT714B T*C036-120 (A or E)_R T*C036-120 (A or E)_R CO2 Sensor Kit (Wall Mounted) CO2 Sensor Kit (Duct Mounted) For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-15 Effective 7/1/12 14-1011-28 ReliaTel™ Controls Packaged Unit Protection/Operation Timings and Features Alternating Lead/Lag – Dual Compressor Models Only — During periods of part load operation, each compressor cycles alternately as circuit number one, equalizing compressor wear and run time. Enabled by cutting the wire (BLUE) at (RTRM) junction number J3-8. Standard Increased Reliability — Fewer components (moving electromechanical parts), less likelihood of equipment down time or failure. Standard Anti Short Cycle Timer (ASCT) Function — Provides a three (3) minute minimum “ON” time and a three (3) minute minimum “OFF” time for compressors, enhances compressor reliability by ensuring proper oil return. Standard Built In Evaporator Defrost Control (EDC) Function — Provides low ambient cooling down to 0°F. Standard Built In Night Set Back and Unoccupied Functions1 — When using a standard dual setpoint/auto change over Zone Sensor Module (ZSM), this function is enabled by applying a short across terminal J6-11 and J6-12. Sets cooling setpoint up a minimum of 7°F, sets heating setpoint back a minimum of 7°F, forces outside air damper (if present) minimum position to zero, and forces fan operation to automatic. Accessory (requires time clock accessory or field supplied/installed switch or contacts). Built In “TEST” Mode — Aids in quick verification of system and control operation, exercises both hardware and software (no special tools required). Standard Built In Unoccupied Mode1 — When using a standard single setpoint/manual change over Zone Sensor Module (ZSM), this function is enabled by applying a short across terminal J6-11 and J6-12. Forces outside air damper (if present) minimum position to zero, forces fan operation to automatic. Accessory (requires time clock accessory or field supplied/installed switch or contacts). Direct Digital Control (DDC)1 — Proportional Integral (PI) control. Proportional – sets corrective action proportional to deviation from setpoint. Integral – fine tunes the rate of corrective action proportional to the error (results in superior space temperature control). Standard Economizer Preferred Cooling1 — Provides fully integrated operation if required. Will not turn on a compressor with the economizer, if the space is recovering adequately with the economizer alone (0.2°F/ minute). Allows the equipment to be utilized in more varied applications. Standard with economizer accessory. Emergency Stop Terminals On Low Voltage Terminal Board (LTB-5 and LTB-6) — Provides a convenient point to disable the equipment completely, and immediately. Still provides communication to BAS. Standard Heat Pump Soft Start — Provides a smooth transition into heating after defrost, minimizing noise and compressor stress associated with switch over. Standard Intelligent Fallback1 — A built in Default Control provides adaptive operation, which allows the equipment to continue to operate, providing comfort in the event of certain component failures. Also, allows emergency operation without a Zone Sensor Module (ZSM). Standard Low Ambient Start Timer (LAST) Function — Bypasses low pressure control when a compressor starts, eliminating nuisance compressor lock outs. Standard Built In Fan Delay Relay (FDR) Function — Provides custom indoor fan timing sequences for the different types of equipment, enhancing efficiency and reliability. Standard Heat Pump Smart Recovery and Smart Staging1 — Inhibits auxiliary heat operation if the space is recovering adequately (0.1°F/minute) with the heat pump alone, providing considerable savings in operating costs. Standard Integral Electric Heat Staging1 — Stages electric heaters “OFF” and “ON”, eliminating the use of outdated sequencers. Standard Lower Installation Cost — Using a standard Zone Sensor Module (ZSM), control voltage wiring may be run up to five (5) times further than any electromechanical system, with no increase in wire gauge. Example: Electromechanical System – 30 feet maximum using 22 gauge wire. Micro Control System – 150 feet using 22 gauge wire. Standard On Board Diagnostics1 — Assist with equipment troubleshooting, if a problem occurrence should take place. Standard Remote Sensing1 — All standard Zone Sensor Modules (ZSMs) have remote sensing capabilities, typically achieved by using an expensive program-mable thermostat and remote sensor with electromechanical equipment. Accessory (requires use of remote sensor). Selectable Economizer Dry Bulb Change Over — Allows the capability of selecting the following dry bulb change over points: 63, 67, 70 or 73°F. Standard with economizer accessory. Space Temperature Averaging1 — All standard Zone Sensor Modules (ZSMs) have space temperature averaging capabilities, typically achieved by using an expensive programmable thermostat and minimum of four (4) remote sensors with electromechanical equipment. Averaging with ReliaTel™ can be achieved with two (2) sensors. Supply Air Tempering1 — A built in feature, once enabled only through an ICS device, may also be enabled using a digital or programmable Zone Sensor Module. When in the HEAT mode (and not actively heating), if supply air temperature drops 10°F below the heating setpoint, heat is turned on until supply air temperature rises to a point 10°F above the heating setpoint. Provides temperate air during the “OFF” cycle, and eliminates cold air dumping from supply ducts. Extremely effective when introducing any quantity of fresh air. Standard when using a RTOM, ICS device, digital, or programmable Zone Sensor Module. Time Delay Relay (TDR) Function — Provides an incremental staging delay between compressors, minimizes equipment current inrush and consumption by keeping compressors from starting simultaneously. Standard Low Pressure and High Pressure Compressor Lockout — 3 trips will lockout control. 1 Denotes features lost from utilizing standard conventional stat. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-16 Effective 7/1/12 14-1011-28 ReliaTel™ Controls Operation With An Electromechanical Thermostat When the ReliaTel™ RTRM Thermostat Interface is used, equipment operation differs significantly. The basic equipment protection features remain intact, and the following features and benefits are lost: •Direct Digital Control (DDC) – Proportional Integral (PI) control is lost, equipment is controlled by a thermostat or generic building automation system device. •Intelligent Fall back is lost, if a failure occurs in the device controlling the equipment, operation will cease. •Installation is more costly, with the addition of a thermostat or generic control, the control wiring size must be increased. •Heat Pump Smart Recovery and Smart Staging is lost, Heat Pump operation becomes more costly unless generic control being applied can accomplish this. •Remote Sensing capabilities are lost, unless generic control being applied can accomplish this. •Low ambient disabled economizer and second condensing fan cycling capability. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-17 •Space Temperature Averaging capabilities are lost, unless generic control being applied can accomplish this. •Supply Air Tempering feature is lost, discharge air temperature may be cold when not actively heating if outdoor air is being introduced through the equipment. •Built In Night Set Back and Unoccupied functions are lost, unless generic control being applied can accomplish this. •Built In Unoccupied Mode is lost, unless generic control being applied can accomplish this. •Economizer Preferred Cooling Feature is lost, all compressor operation is locked out below 50°F. Effective 7/1/12 14-1011-28 Packaged Cooling with ReliaTel™ Controls 12½-25 Tons, R-410A 12½-25 Ton TCD-F – Downflow 12½-25 Ton TCH-F – Horizontal • Reliatel™ control features are listed on page PC-16 • Built-in anti-short cycle, time-delay relay and minimum on time controls • 2" throwaway filters • Liquid line drier • Built-in fork lift holes • Operating charge of R-410A • Quick-Access on 12½ – 25 • Sloped sheet metal drain pan • Dedicated horizontal and downflow units • Single point power for electric heat • Complete line of optional electric heaters • Internally enhanced coil tubing • Low ambient to 0°F standard • Colored and numbered wiring • Phase monitor • Quick-adjust idler arm pulley. Adjust belt tension, change belts, adjust airflow quickly (12½ – 25 tons), downflow only • UL listed and CSA certified • 5-year limited compressor warranty (12½ – 17½ tons) • 1-year limited compressor warranty (20 and 25 tons) Table PC-18-A — TCD-F, TCH-F— Ultra High Efficiency Tons Unit Model No. Power Supply Volts/Phase/Hz Performance Cooling EER Capacity (Btuh) Dimensions (in.) H x W x L Shipping Max Fuse Size or Downflow3 Weight (Ibs.) MCA2Max Circuit Breaker1 Roofcurb 121/2 TC*151F300A 208-230/3/60 12.1 140,000 54 x 855/16 x 1225/16 2373 65 80 BAYCURB027B 15 TC*181F300A 208-230/3/60 12.0 172,000 64 1/8 x 855/16 x 1225/16 2322 72 90 BAYCURB027B 171/2 TC*211F300A 208-230/3/60 11.8 198,000 64 1/8 x 855/16 x 1225/16 2396 88 110 BAYCURB027B 20 TC*241F300A 208-230/3/60 11.0 242000 64 1/8 x 855/16 x 1225/16 2399 104 125 BAYCURB027B 25 TC*301F300A 208-230/3/60 10.6 272000 64 1/8 x 855/16 x 1225/16 2365 116 150 BAYCURB027B 121/2 TC*151F400A 460/3/60 12.1 140,000 54 x 855/16 x 1225/16 2373 32 40 BAYCURB027B 15 TC*181F400A 460/3/60 12.0 172,000 641/8 x 855/16 x 1225/16 2322 36 45 BAYCURB027B 171/2 TC*211F400A 460/3/60 11.8 198,000 641/8 x 855/16 x 1225/16 2396 42 50 BAYCURB027B 20 TC*241F400A 460/3/60 11.0 242000 641/8 x 855/16 x 1225/16 2399 50 60 BAYCURB027B 25 TC*301F400A 460/3/60 10.6 272000 641/8 x 855/16 x 1225/16 2365 56 70 BAYCURB027B 121/2 TC*151FW00A 575/3/60 12.1 140,000 54 x 855/16 x 1225/16 2373 25 30 BAYCURB027B 15 TC*181FW00A 575/3/60 12.0 172,000 641/8 x 855/16 x 1225/16 2322 29 40 BAYCURB027B 171/2 TC*211FW00A 575/3/60 11.8 198,000 641/8 x 855/16 x 1225/16 2396 36 45 BAYCURB027B 20 TC*241FW00A 575/3/60 11.0 242000 641/8 x 855/16 x 1225/16 2399 42 50 BAYCURB027B 25 TC*301FW00A 575/3/60 10.6 272000 641/8 x 855/16 x 1225/16 2365 47 60 BAYCURB027B Table PC-18-B — TCD-F, TCH-F - Ultra High Efficiency - Multi Speed Indoor Fan Tons Unit Model No. Power Supply Volts/Phase/Hz Performance Cooling EER Capacity (Btuh) Dimensions (in.) H x W x L Shipping Max Fuse Size or1Downflow Weight (Ibs.) MCA2 Max Circuit Breaker* Roofcurb 121/2 TC*151F3A0A 208-230/3/60 12.1 140,000 54 x 855/16 x 1225/16 2398 65 80 BAYCURB027B 15 TC*181F3A0A 208-230/3/60 12.0 172,000 641/8 x 855/16 x 1225/16 2347 72 90 BAYCURB027B 171/2 TC*211F3A0A 208-230/3/60 11.8 198,000 641/8 x 855/16 x 1225/16 2421 88 110 BAYCURB027B 20 TC*241F3A0A 208-230/3/60 11.0 242000 641/8 x 855/16 x 1225/16 2424 104 125 BAYCURB027B 25 TC*301F3A0A 208-230/3/60 10.6 272000 641/8 x 855/16 x 1225/16 2430 116 150 BAYCURB027B 121/2 TC*151F4A0A 460/3/60 12.1 140,000 54 x 855/16 x 1225/16 2398 32 40 BAYCURB027B 15 TC*181F4A0A 460/3/60 12.0 172,000 641/8 x 855/16 x 1225/16 2347 36 45 BAYCURB027B 171/2 TC*211F4A0A 460/3/60 11.8 198,000 641/8 x 855/16 x 1225/16 2421 42 50 BAYCURB027B 20 TC*241F4A0A 460/3/60 11.0 242000 641/8 x 855/16 x 1225/16 2424 50 60 BAYCURB027B 25 TC*301F4A0A 460/3/60 10.6 272000 641/8 x 855/16 x 1225/16 2410 56 70 BAYCURB027B 121/2 TC*151FWA0A 575/3/60 12.1 140,000 54 x 855/16 x 1225/16 2398 25 30 BAYCURB027B 15 TC*181FWA0A 575/3/60 12.0 172,000 641/8 x 855/16 x 1225/16 2347 29 40 BAYCURB027B 171/2 TC*211FWA0A 575/3/60 11.8 198,000 641/8 x 855/16 x 1225/16 2421 36 45 BAYCURB027B 20 TC*241FWA0A 575/3/60 11.0 242000 641/8 x 855/16 x 1225/16 2424 42 50 BAYCURB027B 25 TC*301FWA0A 575/3/60 10.6 272000 641/8 x 855/16 x 1225/16 2410 47 60 BAYCURB027B 1HACR type circuit breaker per NEC. 2Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. 3Downflow only. 4278,000 in the horizontal airflow configuration. * Digit 3 - H = Horizontal or D = Downflow. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-18 Effective 7/1/12 14-1011-28 Packaged Cooling with ReliaTel™ Controls 12½-25 Tons, R-410A 12½-25 Ton TCD-F – Downflow 12½-25 Ton TCH-F – Horizontal • Reliatel™ control features are listed on page PC-16 • Built-in anti-short cycle, time-delay relay and minimum on time controls • 2" throwaway filters • Liquid line drier • Built-in fork lift holes • Operating charge of R-410A • Quick-Access on 12½ – 25 • Sloped sheet metal drain pan • Dedicated horizontal and downflow units • Single point power for electric heat • Complete line of optional electric heaters • Internally enhanced coil tubing • Low ambient to 0°F standard • Colored and numbered wiring • Phase monitor • Quick-adjust idler arm pulley. Adjust belt tension, change belts, adjust airflow quickly (12½ – 25 tons), downflow only • UL listed and CSA certified • 5-year limited compressor warranty (12½ – 17½ tons) • 1-year limited compressor warranty (20 and 25 tons) Table PC-19-A — TCD-F, TCH-F - Standard Efficiency Tons Unit Model No. Power Supply Volts/Phase/Hz Performance Cooling EER) Capacity (Btuh) Dimensions (in.) H x W x L Shipping Max Fuse Size or Downflow3 Weight (Ibs.) MCA2Max Circuit Breaker1 Roofcurb 121/2 TC*150F300B 208-230/3/60 11.0 140,000 501/8 x 715/8 x 1075/16 1781 64 80 BAYCURB026B 15 TC*180F300B 208-230/3/60 11.0 176,000 54 x 855/16 x 1225/16 2281 75 100 BAYCURB027B 171/2 TC*210F300B 208-230/3/60 11.0 193,000 54 x 855/16 x 1225/16 2292 93 125 BAYCURB027B 20 TC*240F300B 208-230/3/60 10.0 240,000 54 x 855/16 x 1225/16 2353 108 125 BAYCURB027B 25 TC*300F300B 208-230/3/60 10.0 272,000 54 x 855/16 x 1225/16 2337 124 150 BAYCURB027B 121/2 TC*150F400B 460/3/60 11.0 140,000 501/8 x 715/8 x 1075/16 1781 31 40 BAYCURB026B 15 TC*180F400B 460/3/60 11.0 176,000 54 x 85 5/16 x 1225/16 2281 28 50 BAYCURB027B 171/2 TC*210F400B 460/3/60 11.0 193,000 54 x 85 5/16 x 1225/16 2292 44 60 BAYCURB027B 20 TC*240F400B 460/3/60 10.0 240,000 54 x 85 5/16 x 1225/16 2353 52 70 BAYCURB027B 25 TC*300F400B 460/3/60 10.0 272,000 54 x 85 5/16 x 1225/16 2337 59 70 BAYCURB027B 121/2 TC*150FW00B 575/3/60 11.0 140,000 501/8 x 715/8 x 1075/16 1781 23 30 BAYCURB026B 15 TC*180FW00B 575/3/60 11.0 176,000 54 x 855/16 x 1225/16 2281 31 40 BAYCURB027B 171/2 TC*210FW00B 575/3/60 11.0 193,000 54 x 855/16 x 1225/16 2292 35 50 BAYCURB027B 20 TC*240FW00B 575/3/60 10.0 240,000 54 x 855/16 x 1225/16 2353 44 60 BAYCURB027B 25 TC*300FW00B 575/3/60 10.0 272,000 54 x 855/16 x 1225/16 2337 48 60 BAYCURB027B Table PC-19-B — TCD-F, TCH-F - Standard Efficiency (Multi Speed Indoor Fan) Tons Unit Model No. Power Supply Volts/Phase/Hz Performance Cooling EER Capacity (Btuh) Dimensions (in.) H x W x L Shipping Max Fuse Size or1Downflow Weight (Ibs.) MCA2 Max Circuit Breaker* Roofcurb 121/2 TC*150F3A0B 208-230/3/60 11.0 140,000 501/8 x 715/8 x 1075/16 1806 64 80 BAYCURB026B 15 TC*180F3A0B 208-230/3/60 11.0 176,000 54 x 855/16 x 1225/16 2306 75 100 BAYCURB027B 171/2 TC*210F3A0B 208-230/3/60 11.0 193,000 54 x 855/16 x 1225/16 2317 93 125 BAYCURB027B 20 TC*240F3A0B 208-230/3/60 10.0 240,000 54 x 855/16 x 1225/16 2378 108 125 BAYCURB027B 25 TC*300F3A0B 208-230/3/60 10.0 272,000 54 x 855/16 x 1225/16 2402 124 150 BAYCURB027B 121/2 TC*150F4A0B 460/3/60 11.0 140,000 501/8 x 715/8 x 1075/16 1806 31 40 BAYCURB026B 15 TC*180F4A0B 460/3/60 11.0 176,000 54 x 855/16 x 1225/16 2306 28 50 BAYCURB027B 171/2 TC*210F4A0B 460/3/60 11.0 193,000 54 x 855/16 x 1225/16 2317 44 60 BAYCURB027B 20 TC*240F4A0B 460/3/60 10.0 240,000 54 x 855/16 x 1225/16 2378 52 70 BAYCURB027B 25 TC*300F4A0B 460/3/60 10.0 272,000 54 x 855/16 x 1225/16 2382 59 70 BAYCURB027B 121/2 TC*150FWA0B 575/3/60 11.0 140,000 501/8 x 715/8 x 1075/16 1806 23 30 BAYCURB026B 15 TC*180FWA0B 575/3/60 11.0 176,000 54 x 855/16 x 1225/16 2306 31 40 BAYCURB027B 171/2 TC*210FWA0B 575/3/60 11.0 193,000 54 x 855/16 x 1225/16 2317 35 50 BAYCURB027B 20 TC*240FWA0B 575/3/60 10.0 240,000 54 x 855/16 x 1225/16 2378 44 60 BAYCURB027B 25 TC*300FWA0B 575/3/60 10.0 272,000 54 x 855/16 x 1225/16 2382 48 60 BAYCURB027B 1HACR type circuit breaker per NEC. 2Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. 3Downflow only. 4278,000 in the horizontal airflow configuration. * Digit 3 - H = Horizontal or D = Downflow. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-19 Effective 7/1/12 14-1011-28 Packaged Cooling with ReliaTel™ Controls 12½-25 Tons FIOPS Table PC-20-A — Factory Installed Accessories12 For Complete list of all Factory Installed Options, please refer to the FIOPS section of this book. Digit Description 1-9 10 11-12 Main Assembly (see previous page) Factory Installed Options No Options Downflow Economizer3 Oversized Motor Downflow Economizer and Oversized Motor3 TXV/Face - Split Evaporator Oversized Motor and TXV/Face -Split Evaporator Downflow Economizer, Oversized Motor and TXV/Face Split Evaporator3 Downflow Economizer with TXV/Face - Split Evaportor3 Reheat Coil4 Downflow Economizer with Reheat Coil3 Oversized Motor and Reheat Coil4 Downflow Economizer, Oversized Motor and Reheat Coil 34 Minor Design and Service Sequence Order Number Used With 0 A B C H J K TC*150-301 TCD150-301 TC*150-241 TCD150-241 TCD151, 181, 211, 241, 301 TCD151, 181, 211, 241 TCD151, 181, 211, 241 L M N P R TCD151, 181, 211, 241, 301 TCD151, 181, 241 TCD151, 181, 241 TCD151, 181, 241 TCD151, 181, 241 ** 1Price includes accessory and factory installation. 2Four (4) week shipping approximately. 3Some field set up required. 4All 10th digit model numbers including reheat coil (M,N,P,R) require additional factory installed options; ReliaTel™ Options Module (FIYABRD002B), Frostat (FIYLOAM023A or FIYLOAM031A), and 2" Pleated Filters (refer to FIOPS section for appropriate model number usage). For these or any Factory Installed Options not included in 10th digit model number, digits 1-3 must be TFD. Packaged Cooling with ReliaTel™ Controls 12½-25 Tons, R-410A Zone Sensors / Thermostats Table PC-20-B — Zone Sensors for ReliaTel™ Model Number Description Used With ASYSTAT106A ASYSTAT108A ASYSTAT111A ASYSTAT777A ASYSTAT710A ASYSTAT711A BAYMTPL110A Single Setpoint Manual Changeover Dual Setpoint Manual or Automatic Changeover Remote Room Sensor Programmable Night Setback Wall Mounted Humidity Sensor Duct Mounted Humidity Sensor Retrofit Wall Cover Plate Kit 7.25" x 6.0" YC*150-301 YC*150-301 ASYSTAT777A YC*150-301 YFD151,181,241 (with Reheat) YFD151,181,241 (with Reheat) ASYSTAT777A For additional Controls Information: See ReliaTel™ and Micro Control features on PC-16 and PC-17. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-20 Effective 7/1/12 14-1011-28 Packaged Cooling with ReliaTel™ Controls 12½-25 Tons Accessories Table PC-21-A — Field Installed Accessories For complete list of of All Factory Installed Options refer to FIOPS section of this book. Model Number Description Used With BAYBCIR001A................ BACnet™ Communication Interface............................................... TC*150F-TC*301F BAYABRD0028.............. ReliaTel™ Options Module............................................................. TC*150F-TC*301F ASYSTAT713B9............. CO2 Sensor Wall Mounted............................................................. TC*150F-TC*301F w/Economizer ASYSTAT715B9............. CO2 Sensor Duct Mounted............................................................. TC*150F-TC*301F w/Economizer BAYCURB026B56........ Downflow Roof Curb (Can not be adapted for horizontal use) ...... TCD150F BAYCURB027B56........ Downflow Roof Curb (Can not be adapted for horizontal use) ...... TCD151F-TCD301F, TCD180F-300F BAYDFPS005A78......... Clogged Filter Switch (MERV 7)..................................................... TC*150F-TC*301F BAYDFPS006A78......... Fan Failure Switch.......................................................................... TC*150F-TC*301F BAYDFPS013A............... Clogged Filter Switch (MERV 13)................................................... TC*150F-TC*301F BAYDMPR029C.............. 0-25% Manual Outside Air Damper................................................ TC*150F-TC*301F BAYDMPR057A.............. 0-50% Motorized Outside Air Damper............................................ TC*150F BAYDMPR058A.............. 0-50% Motorized Outside Air Damper............................................ TC*151F-TC*301F, TC*180F-300F BAYECON089A8........... Downflow Economizer with Barometric Relief................................ TCD150F BAYECON090A8........... Downflow Economizer with Barometric Relief................................ TCD151F-TCD301F, TCD180F-300F BAYECON091A.............. Horizontal Economizer .................................................................. TCH150F BAYECON092A.............. Horizontal Economizer .................................................................. TCH151F-TCH301F, TCH180F-300F BAYENTH007A12 ........ Reference Enthalpy Kit................................................................... All BAYECON089-92A BAYENTH008A13 ........ Comparative Enthalpy Kit............................................................... All BAYECON089-92A BAYFRST003A............... High Temperature Stat................................................................... TC*150F-TC*300F, TC*151F-301F BAYGARD144A8........... Tool-less Hail Guard....................................................................... TC*150F BAYGARD145A8........... Tool-less Hail Guard....................................................................... TC*151F, TC*210F, TC*240F, TC*300F BAYGARD150A.............. Tool-less Hail Guard....................................................................... TC*181F, TC*211F, TC*241F, TC*301F BAYHSDR005B4........... High Static Drive............................................................................ TC*150F, TC*151F, TC*181F BAYHSDR010A4........... High Static Drive............................................................................ TC*211F, TC*241F. TC*300F BAYHSDR011A4........... High Static Drive............................................................................ TC*210F, TC*240F, TC*301F BAYHSDR016A.............. High Static Drive............................................................................ TC*180F 1 Kit contains all necessary parts to achieve desired level of Enthalpy Control. 2 Reference Enthalpy senses outside temperature/humidity and inside return/mixed air temperature/humidity. 3 Comparative Enthalpy senses outside temperature/humidity and inside return/mixed air temperature/humidity. 4 High static drive and oversized motors are mutually exclusive, Do Not Combine. 5 Clarksville manufacturing has a no return policy for this roof curb. 6 For downflow use only. Can not be adapted for horizontal units. 7BAYABRD002B is required when ordering field installed BAYDFPS005A or 006A, BAYTUBE008A or 009A and BAYLOAM023A or BAYVNOR002B. 8Field or factory installed option. 9Field installed accessory. Requires an economizer. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-21 Effective 7/1/12 14-1011-28 Packaged Cooling with ReliaTel™ Controls 12½-25 Tons Accessories Table PC-22-A — Field Installed Accessories For complete list of of All Factory Installed Options refer to FIOPS section of this book. Model Number Description Used With BAYHSMT039B16........ 5HP Oversized Motor Kit (208-230/460V)..................................TC*150F BAYHSMT040B16........ 5HP Oversized Motor Kit (575V)................................................TC*150F BAYHSMT055B16........ 5HP Oversized Motor Kit (208-230/460V)..................................TC*180F BAYHSMT042A16........ 7-1/2HP Oversized Motor Kit (575V)..........................................TC*210F, TC*211F, TC*240E, TC*241F BAYHSMT072A16........ 7-1/2HP Oversized Motor Kit (575V)..........................................TC*180F, TC*181F BAYHSMT098A16........ 7-1/2HP Oversized Motor Kit (208-230V)...................................TC*211F, TC*241F BAYHSMT099A16........ 7-1/2HP Oversized Motor Kit (460V)..........................................TC*211F, TC*241F BAYLOAM023A6........... Evaporator Defrost Control Frostat.............................................TC*150F, TC*151F, TC*180F, TC*210F, TC*240F, TC*300F BAYLOAM031A.............. Evaporator Defrost Control Frostat.............................................TC*211F, TC*241F, TC*301F, TC*181F BAYLSDR004A2............ Low Static Drive.........................................................................TC*150F, TC*180F, TC*210F, TC*211F, TC*240F, TC*241F BAYLSDR002A2............ Low Static Drive.........................................................................TC*151F, TC*181F, TC*300F BAYPWRX029A.............. Power Exhaust for all Voyagers 12½-25 Ton 230V units.............BAYECON089-090A, TCD150-301 BAYPWRX030A.............. Power Exhaust for all Voyagers 12½-25 Ton 460V units.............BAYECON089-090A, TCD150-301 BAYPWRX031A.............. Power Exhaust for all Voyagers 12½-25 Ton 575V units.............BAYECON089-090A, TCD150-301 BAYSERV001A............... Selective Resistance Service Tester..........................................All TC*150F-TC*301F BAYSTAT0233................ Remote Potentiometer...............................................................All Economizers and 0-50% Motorized Air Dampers BAYTUBE008A456...... Discharge Air Sensing Kit..........................................................All TCD150F-TCD301F BAYTUBE009A456...... Discharge Air Sensing Kit..........................................................All TCH150F-TCH301F BAYQACB044A.............. Adapter Curb..............................................................................BAYCURB026A/B to BAYCURB027A/B BAYVNOR002B5........... Ventilation Override Kit...............................................................TC*150-301 w/ReliaTel™ Options Module 1High static drive and oversized motors are mutually exclusive, Do Not Combine. 2Low static drive and oversized motors are mutually exclusive, Do Not Combine. 3Cannot be used with Integrated Comfort™ Systems. 4Used for true discharge air sensing in both heating and cooling models. 5BAYABRD002B is required when ordering field installed BAYDFPS005A or 006A, BAYTUBE008A or 009A and BAYLOAM031A or BAYVNOR002B. 6Field or factory installed option. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-22 Effective 7/1/12 14-1011-28 Packaged Cooling with ReliaTel™ Controls 12½-25 Tons Heaters Table PC-23-A — Downflow Supplementary Heaters: ModelPower Number Supply AYDHTRK318A AYDHTRK336A AYDHTRK354A 208-230/3/60 208-230/3/60 208-230/3/60 kW Nominal Rating BTUH 13.5/18.0 27.0/36.0 40.5/54.0 AYDHTRL418A 460/3/60 AYDHTRK427A460/3/60 AYDHTRK436A 460/3/60 AYDHTRK454A 460/3/60 AYDHTRL336A AYDHTRL354A AYDHTRK372A 208-230/3/60 208-230/3/60 208-230/3/60 AYDHTRL427A AYDHTRL436A AYDHTRL454A AYDHTRK472A 460/3/60 460/3/60 460/3/60 460/3/60 18.0 27.0 36.0 54.0 27.0/36.0 40.5/54.0 54.0/72.0 27.0 36.0 54.0 72.0 No. Stages Used With 46,100/61,400 92,200/122,900 138,200/184,300 1 2 2 TCD150F-180F, TCD151F-181F TCD150F-180F, TCD151F-181F TCD150F-180F, TCD151F-181F 61,400 92,150 122,900 184,300 1 2 2 2 TCD150F-180F, TCD151F-181F TCD181F TCD150F-180F, TCD151F-181F TCD150F-180F, TCD151F-181F 92,200/122,900 138,200/184,300 184,300/245,700 2 2 2 TCD210F-300F, TCD211F-301F TCD210F-300F, TCD211F-301F TCD210F-300F, TCD211F-301F 92,150 122,900 184,300 245,700 2 2 2 2 TCD211F, TCD241F, TCD301F TCD210F-300F, TCD211F-301F TCD210F-300F, TCD211F-301F TCD210F-300F, TCD211F-301F Table PC-23-B — Horizontal Supplementary Heaters: ModelPower Number Supply AYHHTRN318A AYHHTRP336A AYHHTRP354A 208-230/3/60 208-230/3/60 208-230/3/60 AYHHTRN418A AYHHTRP436A AYHHTRP454A 460/3/60 460/3/60 460/3/60 AYHHTRN336A AYHHTRN354A AYHHTRN372A AYHHTRN436A AYHHTRN454A AYHHTRN472A 208-230/3/60 208-230/3/60 208-230/3/60 AYHHTRM318A AYHHTRM336A AYHHTRM354A 208-230/3/60 208-230/3/60 208-230/3/60 AYHHTRM418A AYHHTRM436A AYHHTRM454A 460/3/60 460/3/60 460/3/60 kW Nominal Rating BTUH 13.5/18.0 27.0/36.0 40.5/54.0 18.0 36.0 54.0 27.0/36.0 40.5/54.0 54.0/72.0 460/3/60 460/3/60 460/3/60 36.0 54.0 72.0 13.5/18.0 27.0/36.0 40.5/54.0 18.0 36.0 54.0 No. Stages Used With 46,000/61,400 92,200/122,900 138,200/184,300 1 2 2 TCH150F, TCH180F TCH150F, TCH180F TCH150F, TCH180F 61,400 122,900 184,300 1 2 2 TCH150F, TCH180F TCH150F, TCH180F TCH150F, TCH180F 92,200/122,900 138,200/184,300 184,300/245,700 2 2 2 TCH210F-300F, TCH211F-301F TCH210F-300F, TCH211F-301F TCH210F-300F, TCH211F-301F 122,900 184,300 245,700 2 2 2 TCH210E-300F, TCH211F-301F TCH210E-300F, TCH211F-301F TCH210E-300F, TCH211F-301F 46,100/61,400 92,200/122,900 138,200/184,300 1 2 2 TCH151F, TCH181F TCH151F, TCH181F TCH151F, TCH181F 61,400 122,900 184,300 1 2 2 TCH151F, TCH181F TCH151F, TCH181F TCH151F, TCH181F Note: Unit with heater is single circuit/single point. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-23 Effective 7/1/12 14-1011-28 Packaged Cooling with ReliaTel™ Controls 12½-25 Tons Heaters Table PC-24-A — Downflow Supplementary Heaters: ModelPower Number Supply kW NominalNo. Rating BTUH Stages Used With AYDHTRLW54A575/3/60 54.0 184,300 2 TCD210F-300F, TCD211F-301F AYDHTRKW18A575/3/60 AYDHTRKW54A575/3/60 AYDHTRKW72A575/3/60 18.0 54.0 72.0 61,400 184,300 245,700 1 2 2 TCD150F-180F, TCD151F-181F TCD150F-180F, TCD151F-181F TCD210F-300F, TCD211F-301F AYDHTRMW36A 36.0 122,900 2 TCD150F-300F, TCD151F-301F 575/3/60 Table PC-24-B — Horizontal Supplementary Heaters: ModelPower Number Supply kW NominalNo. Rating BTUH Stages Used With AYHHTRMW18A AYHHTRMW36A AYHHTRMW54A 575/3/60 575/3/60 575/3/60 18.0 36.0 54.0 61,400 122,900 184,300 1 2 2 TCH151F, TCH181F TCH210F-300F, TCH151E-301F TCH151F, TCH181F AYHHTRNW18A AYHHTRNW54A AYHHTRNW72A AYHHTRPW36A AYHHTRPW54A 575/3/60 575/3/60 575/3/60 575/3/60 575/3/60 18.0 54.0 72.0 36.0 54.0 61,400 184,300 245,700 122,900 184,300 1 2 2 2 2 TCH150F, TCH180F TCH210F-300F, TCH211F-301F TCH210F-300F, TCH211F-301F TCH150F, TCH180F TCH150F, TCH180F Note: Unit with heater is single circuit/single point. For additional Controls Information: See ReliaTel™ and Micro Control features on PC-16 and PC-17. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PC-24 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 2-5 Tons Table PH-1-A — 4WCZ6 - Platinum ZM (Previously Heritage® 16) Convertible Packaged Heat Pump - R-410A Cabinet Model EER Shipping Max Sound Dimensions (in.) Number Capacity SEERHigh/Low HSPF WeightMCA Fuse Rating H x D xW 4WCZ6 Platinum ZM 4WCZ6 – 208-230/1/60 4WCZ6036A1000B 36,000 16.40 12.20/13.30 9.00 468 26.2 40 70 38 x 43 x 51 4WCZ6048A1000B 47,500 16.00 12.00/13.60 9.00 607 34.1 50 71 42 x 46 x 61 4WCZ6060A1000B 56,500 15.20 11.50/12.50 8.60 623 37.1 60 73 42 x 46 x 61 4WCZ6 – 208-230/3/60 4WCZ6036A3000B 36,000 16.40 12.20/13.30 9.00 468 19.1 30 70 38 x 43 x 51 4WCZ6048A3000B 47,500 16.00 12.00/13.60 9.00 607 24.5 35 71 42 x 46 x 61 4WCZ6060A3000B 56,500 15.20 11.50/12.50 8.60 623 30.3 45 73 42 x 46 x 61 4WCZ6 – 460/3/60 4WCZ6036A4000B 36,000 16.40 12.20/13.30 9.00 468 10.4 15 70 38 x 43 x 51 4WCZ6048A4000B 47,500 16.00 12.00/13.60 9.00 607 15.3 20 71 42 x 46 x 61 4WCZ6060A4000B 56,500 15.20 11.50/12.50 8.60 623 19.2 25 73 42 x 46 x 61 Table PH-1-B — 4DCZ6 - Platinum ZM (Previously Heritage Hybrid™ Comfort 16) Convertible Packaged Heat Pump - R-410A Model Number 4DCZ6 Platinum ZM Cooling Gas Cabinet Capacity Capacity Heating Shipping Max Sound Dimensions (in.) (BTUH) Output (1 Stg./2 Stg.) SEER/EER HSPFAFUE(%)Weight MCA Fuse Rating H x D xW 4DCZ6 – 208-230/1/60 4DCZ6036A1075B 35,000 48,400/60,000 16.00 /12.00 9.00 79.5 488 26.2 40 70 4DCZ6048A1096B 47,500 62,000/77,000 16.00 /12.00 9.00 80.0 665 34.1 50 71 4DCZ6060A1120B 57,000 77,500/96,000 15.20 /11.50 8.60 80.0 676 37.1 60 73 4DCZ6 – 208-230/3/60 4DCZ6036A3075B 35,000 48,400/60,000 16.00 /12.00 9.00 79.5 488 19.1 30 70 4DCZ6048A3096B 47,500 62,000/77,000 16.00 /12.00 9.00 80.0 665 24.5 35 71 4DCZ6060A3120B 57,000 77,500/96,000 15.20 /11.50 8.60 80.0 676 30.3 45 73 38 x 43 x 51 42 x 46 x 61 42 x 46 x 61 38 x 43 x 51 42 x 46 x 61 42 x 46 x 61 For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-1 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 2-5 Tons Table PH-2-A — 4WCY4 - Gold XM (Previously Heritage® 14) Convertible Packaged Heat Pump - R-410A Cabinet Model Shipping Max Sound Dimensions (in.) Number Capacity SEER/EER HSPF WeightMCA Fuse Rating H x D xW 4WCY4 Gold XM 4WCY4 – 208-230/1/60 4WCY4024A1000A 23,600 14.00/12.00 8.00 453 16.1 25 68 36 x 43 x 51 4WCY4030A1000A 30,000 14.25/12.00 8.00 453 19.2 30 71 36 x 43 x 51 4WCY4036B1000A 37,400 14.25/12.00 8.00 468 24.6 40 69 38 x 43 x 51 4WCY4042A1000A 42,000 14.25/12.00 8.00 607 31.5 50 74 38 x 46 x 61 4WCY4048B1000A 47,500 14.00/12.00 8.00 607 33.9 50 73 38 x 46 x 61 4WCY4060B1000A 58,000 14.00/12.00 8.00 623 39.9 60 76 42 x 46 x 61 4WCY4 – 208-230/3/60 4WCY4036A3000A 36,000 14.00/11.75 8.20 468 19.8 30 69 38 x 43 x 51 4WCY4048A3000A 47,000 14.00/11.75 8.00 607 26.4 40 73 38 x 46 x 61 4WCY4060A3000A 58,000 14.00/11.50 8.00 623 30.6 45 76 42 x 46 x 61 Table PH-2-B — 4DCY4 - Gold XM (Previously Heritage Hybrid™ Comfort 14) Convertible Packaged Heat Pump - R-410A Model Number 4DCY4 Gold XM Cooling Gas Cabinet Capacity Capacity Heating Shipping Max Sound Dimensions (in.) (BTUH) Output (1 Stg./2 Stg.) SEER/EER HSPFAFUE(%)Weight MCA Fuse Rating H x D xW 4DCY4 – 208-230/1/60 4DCY4024A1064A 23,600 38,400/51,000 14.00/12.00 8.00 79.0 481 16.1 25 68 36 x 43 x 51 4DCY4030A1075A 30,000 48,400/60,000 14.25/12.00 8.00 79.5 481 19.1 30 76 36 x 43 x 51 4DCY4036B1075A 37,400 48,400/60,000 14.25/12.00 8.00 79.5 488 24.6 40 69 38 x 43 x 51 4DCY4042A1096A 42,000 62,000/77,000 14.25/12.00 8.00 80.0 653 31.5 50 74 38 x 46 x 61 4DCY4048B1096A 47,500 62,000/77,000 14.00/12.00 8.00 80.0 653 33.9 50 73 38 x 46 x 61 4DCY4060B1120A 58,000 77,500/96,000 14.00/12.00 8.00 80.0 676 39.9 60 76 42 x 46 x 61 4DCY4 – 208-230/3/60 4DCY4036A3075A 36,000 48,400/60,000 14.00/11.40 8.00 79.5 488 19.8 30 69 36 x 43 x 51 4DCY4048A3096A 47,000 62,000/77,000 14.00/11.75 8.00 80.0 653 26.4 40 73 38 x 46 x 61 4DCY4060A3120A 58,000 77,500/96,000 14.00/11.50 8.00 80.0 676 30.6 60 76 42 x 46 x 61 For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-2 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 2-5 Tons 4WCZ64DCZ64WCY44DCY4 3-5 3-5 2-5 2-5 Table PH-3-A — Features • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • SEER up to......................................................................................................................................... 16.4016.0014.2514.25 HSPF up to.......................................................................................................................................... 9.009.008.208.00 Exclusive Duration™ high efficiency compressor with internal overload protection......................... ✔ ✔ ✔ ✔ Factory supplied charge...................................................................................................................... R-410AR-410AR-410AR-410A ✔ ✔ ✔ ✔ Composite Vortica® indoor blower...................................................................................................... High efficiency ECM indoor blower motor with Comfort-R™ airflow system..................................... ✔ ✔ ✔ ✔ All aluminum Spine Fin™ outdoor coil............................................................................................... ✔ ✔ ✔ ✔ Swept-blade outdoor fan for quiet operation....................................................................................... ✔ ✔ ✔ ✔ Architecturally integrated louvers and corner guards......................................................................... ✔ ✔ ✔ ✔ Cabinet constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint......................................................................................................... ✔ ✔ ✔ ✔ Stainless steel heat exchanger and burners....................................................................................... — ✔ — ✔ Single stage cool................................................................................................................................. — — ✔ ✔ Single stage heat................................................................................................................................ — — ✔ — 2-stage gas......................................................................................................................................... — ✔ — ✔ 2-stage heating and cooling................................................................................................................ ✔ ✔ — — Start kit - factory installed (single phase only).................................................................................... — — 2 & 2½ 2 & 2½ High pressure cutout........................................................................................................................... ✔ ✔ ✔ ✔ Low pressure cutout............................................................................................................................ ✔ ✔ ✔ ✔ Liquid line drier - factory installed....................................................................................................... ✔ ✔ ✔ ✔ Non-bleed expansion valves on indoor and outdoor coils.................................................................. ✔ ✔ ✔ ✔ Pressure taps, including liquid line taps, easily accessed and protected inside compressor compartment................................................................................. ✔ ✔ ✔ ✔ Right side electrical service access for high and low voltage connections......................................... ✔ ✔ ✔ ✔ Rugged steel basepan features deep drawn duct connections.......................................................... ✔ ✔ ✔ ✔ Steeply sloped composite drainpan.................................................................................................... ✔ ✔ ✔ ✔ Ships in horizontal configuration and converts quickly for downflow.................................................. ✔ ✔ ✔ ✔ Copper tube, aluminum fin indoor coil................................................................................................ ✔ ✔ ✔ ✔ All models are certified to UL 1995..................................................................................................... ✔ ✔ ✔ ✔ 20-year heat exchanger, 12-year compressor, 10-year outdoor coil, and 10-year all other functional parts registered limited warranty (Residential Use)1................. — ✔ — — 20-year heat exchanger, 10-year compressor, 10-year outdoor coil, and 10-year all other functional parts registered limited warranty (Residential Use)1................. — — — ✔ 12-year compressor, 10-year outdoor coil, and 10-year all other functional parts registered limited warranty (Residential Use)1.............................................. ✔ — — — 10-year compressor, 10-year outdoor coil, and 10-year all other functional parts registered limited warranty (Residential Use)1.............................................. — — ✔ — Extended Warranties Available........................................................................................................ ✔ ✔ ✔ ✔ 1Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-3 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 2-5 Tons 4WCZ64DCZ64WCY44DCY4 3-5 3-5 2-5 2-5 Table PH-4-A — Accessories Model Number Description Shipping Weight 3 2-3 2-3 BAYACCDOR1A.............Hinged Filter Access Doorw...................................................................................................3 BAYACCDOR2A.............Hinged Filter Access Doorw...................................................................................................4-5 4-5 3½-5 3½-5 BAYADAP050A...............Adapter Curb (Cabinet A/B)....................................................................................................3 3 2-3 2-3 BAYADAP051A...............Adapter Curb (Cabinet C).......................................................................................................3 3 2-3 2-3 BAYADAP052A...............Adapter Curb (Cabinet A/B)....................................................................................................4-5 4-5 3½-5 3½-5 BAYADAP053A...............Adapter Curb (Cabinet C).......................................................................................................4-5 4-5 3½-5 3½-5 BAYADAP054A...............Adapter Curb (Cabinet D).......................................................................................................4-5 4-5 3½-5 3½-5 BAYASCT001.................Anti-Short Cycle Timer4........................................................................................................ ✔ ✔ ✔ ✔ BAYCCHT101A..............Crankcase Heater (230V) (Recip.)..........................................................................................— — 2 2 BAYCCHT102A..............Crankcase Heater (230V) (Scroll)........................................................................................... 3, 4, 5 3, 4, 5 3, 5 3, 5 BAYCCHT404B..............Crankcase Heater (460V) (Scroll)........................................................................................... 3, 4, 5 3, 4, 5 3, 5 3, 5 BAYCOVR112A..............12" Duct Shroud (Covers Horizontal Ducts)6......................................................................... 3-53-52-52-5 BAYCOVR118A..............18" Duct Shroud (Covers Horizontal Ducts)6......................................................................... 3-53-52-52-5 BAYCURB050A..............Flat Roof Full Perimeter Curb (Insulated) ...............................................74.............................. 1½-3 3 2-3 2-3 BAYCURB051A..............Flat Roof Full Perimeter Curb (Insulated) ...............................................74.............................. 3½-5 4-5 3½-5 3½-5 BAYDMPR101A.............2-Position Motorized Damper27890 ................................................................................. 1½-3 3 2-3 2-3 BAYDMPR102A.............2-Position Motorized Damper27890..................................................................................4-5 4-5 3½-5 3½-5 BAYECON101A..............Economizer with Barometric Relief (Downflow)12340q....................................................— — 2-3 2-3 BAYECON102A..............Economizer with Barometric Relief (Downflow)12340q....................................................— — 3½-5 3½-5 3 — — BAYECON103A..............Economizer with Barometric Relief (Downflow)12340q .................50..............................3 BAYECON104A..............Economizer with Barometric Relief (Downflow)12340q .................65..............................4-5 4-5 — — — 2-32-3 BAYECON200A..............Economizer (Horizontal)12347..........................................................................................— BAYECON201A .............Economizer (Horizontal)12347..........................................................................................— — 3½-5 3½-5 BAYECON203A..............Economizer (Horizontal)12347........................................................85..............................3 3 — — BAYECON204A..............Economizer (Horizontal)12347........................................................85..............................4-5 4-5 — — BAYECONCOMB101B .....BAYECON101A, door, and filter kit.............................................................................................— — 2-3 2-3 BAYECONCOMB102B...BAYECON102A, door, and filter kit ........................................................................................— — 3½-5 3½-5 BAYECONCOMB103B...BAYECON103A, door, and filter kit......................................................................................... 3 3 — — BAYECONCOMB104B...BAYECON104A, door, and filter kit......................................................................................... 4-5 4-5 — — BAYENTH001A..............Enthalpy Control Kit3............................................................................2............................... ✔ ✔ ✔ ✔ BAYEXMK001A..............Extreme Conditions Mounting Kit............................................................................................ ✔ ✔ ✔ ✔ BAYEXMK002B..............Extreme Conditions Mounting Kit............................................................................................ ✔ ✔ ✔ ✔ BAYEXMK003A..............Extreme Conditions Mounting Kit (Used on Slab Mounts)...................................................... ✔ ✔ ✔ ✔ BAYFLTR101C...............1-2" Filter Frame2-Requires one 20x25 filter (not included)...................6...............................3 3 2-3 2-3 BAYFLTR201C...............1-2" Filter Frame2-Requires one 20x20, and one 20x18 filters (not included)......................................................6...............................4-5 4-5 3½-5 3½-5 BAYLIFT002B.................Lifting Lug Kit ........................................................................................5............................... ✔ ✔ ✔ ✔ BAYLOAM105A..............Low Ambient Control Kit ........................................................................5............................... ✔ ✔ ✔ ✔ — ✔ ✔ BAYRLAY004A...............Economizer Relay1................................................................................................................— BAYRLAY006A...............Economizer Relay1...............................................................................1............................... ✔ ✔ —— BAYOSAC001B..............Outside Air Control for V.S. Economizere................................................................................3,4,5 3,4,5 —— 3 2-3 2-3 BAYOSAH001A..............Manual Fresh Air Damper2 ..................................................................6...............................3 4-5 3½-5 3½-5 BAYOSAH002A..............Manual Fresh Air Damper2 ..................................................................8...............................4-5 — — 1 Phase Only 1 Phase Only BAYQSTK300A..............Start Kit................................................................................................... .............................. BAYSQRD001A..............16" Round Duct Adapter5.....................................................................5...............................3 3 2-3 2-3 BAYSQRD002A..............18" Round Duct Adapter5.....................................................................3............................... 4-54-52-52-5 BAYUTIL101B................Roof Curb Extension Kit..........................................................................................................3 3 2-3 2-3 BAYUTIL102B................Roof Curb Extension Kit..........................................................................................................4-5 4-5 3½-5 3½-5 BAYUV101A...................21" Retrofit UVC Lamp Kit.....................................................................5...............................3 3 2-3 1½-3 BAYUV102A...................33" Retrofit UVC Lamp Kit.....................................................................5...............................4-5 4-5 3½-5 3½-5 1Relay required with economizer on all heat pump applications. 2Must use filter frame when economizer/fresh air kit is used. EXISTING NEW UNIT USE 3Dry bulb control standard with economizer. CURB 4TC/WC/YC/DC****A BAYADAP0**A 42-Stage cooling control required when using economizer. BAYCURB030,38A 018-036 50 5 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. BAYCURB030,38A 018-036 52 6 BAYCOVR112,118A will not cover BAYSQRD002A applications. BAYCURB030,38A 018-036 51 7Does not contain barometric relief. BAYCURB030,38A 018-036 53 8Max fresh air - 25%. BAYCURB030,38A 018-036 54 9For non-continuous fan gas-heating applications, the damper opens only when the OD ambient is above 50° F. 0It is the designer/engineer's responsibility to review product specifications prior to equipment selection to insure optimal performance and compliance to codes. qTemperature of mixed air entering the heat exchanger is monitored and fresh air intake may be reduced under certain conditions. wBAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward compatible to BAYFLTR101/201A. eBAYOSAC001B is not compatible with BAYACCDOR1A or BAYACCDOR2A. For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-4 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 1½-5 Tons Table PH-5-A — 4WCX3 - Gold SI (Previously Heritage® 13) Convertible Packaged Heat Pump - R-410A Cabinet Model Shipping Max Sound Dimensions (in.) Number Capacity SEER/EER HSPF WeightMCA Fuse Rating H x D x W 4WCX3 – 208-230/1/60 4WCX3018A1000A 18,000 13.00/11.00 7.70 444 10.6 15 69 36 x 43 x 51 4WCX3024B1000A 23,400 13.00/11.50 8.00 453 13.6 20 71 36 x 43 x 51 4WCX3030B1000A 29,200 13.00/11.20 8.00 453 17.0 25 74 36 x 43 x 51 4WCX3036A1000A 35,000 13.00/11.00 7.70 468 25.5 40 71 36 x 43 x 51 4WCX3042B1000A 40,000 13.00/11.00 8.00 560 26.5 40 74 38 x 46 x 61 4WCX3048A1000A 46,000 13.00/10.75 7.70 553 31.1 50 73 38 x 46 x 61 4WCX3060A1000A 58,000 13.00/10.85 7.70 618 43.5 60 72 40 x 46 x 61 4WCX3 – 208-230/3/60 4WCX3036A3000A 35,000 13.00/11.00 7.70 468 18.2 30 71 36 x 43 x 51 4WCX3048A3000A 46,000 13.00/10.75 7.70 553 23.6 35 73 38 x 46 x 61 4WCX3060A3000A 58,000 13.00/10.85 7.70 618 31.7 50 72 40 x 46 x 61 4WCX3 – 460/3/60 4WCX3036A4000A 35,000 13.00/11.00 7.70 468 8.7 15 71 36 x 43 x 51 4WCX3048A4000A 46,000 13.00/10.75 7.70 553 11.7 15 73 38 x 46 x 61 4WCX3060A4000A 58,000 13.00/10.85 7.70 618 19.5 25 72 40 x 46 x 61 4WCX3 Gold SI Table PH-5-B — 4WCC3 - Silver SI+ (Previously American Standard 13) Convertible Packaged Heat Pump - R-410A Cabinet Model Shipping Max Sound Dimensions (in.) Number Capacity SEER/EER HSPF WeightMCA Fuse Rating H x D xW 4WCC3 Silver SI+ 4WCC3 – 208-230/1/60 4WCC3018A1000A 18,000 13.00/11.00 7.70 444 10.6 15 74 36 x 42 x 49 4WCC3024B1000A 23,400 13.00/11.00 7.70 453 13.6 20 71 36 x 42 x 49 4WCC3030B1000A 28,000 13.00/11.00 7.70 453 17.0 25 74 36 x 42 x 49 4WCC3036A1000A 35,000 13.00/11.00 7.70 468 25.5 40 75 36 x 42 x 49 4WCC3042B1000A 40,000 13.00/11.00 7.70 560 26.5 40 74 38 x 45 x 59 4WCC3048A1000A 46,000 13.00/10.75 7.70 553 31.1 50 80 38 x 45 x 59 4WCC3060A1000A 58,000 13.00/10.85 7.70 618 43.5 60 79 40 x 45 x 59 4WCC3 – 208-230/3/60 4WCC3036A3000A 35,000 13.00/11.00 7.70 468 18.2 30 75 36 x 42 x 49 4WCC3048A3000A 46,000 13.00/10.75 7.70 553 23.6 35 80 38 x 45 x 59 4WCC3060A3000A 58,000 13.00/10.85 7.70 618 31.7 50 79 40 x 45 x 59 4WCC3 – 460/3/60 4WCC3036A4000A 35,000 13.00/11.00 7.70 468 8.7 15 75 36 x 42 x 49 4WCC3048A4000A 46,000 13.00/10.75 7.70 553 11.7 15 80 38 x 45 x 59 4WCC3060A4000A 58,000 13.00/10.85 7.70 618 19.5 25 79 40 x 45 x 59 For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-5 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 1½-5 Tons 4WCX3 1½-5 Table PH-6-A — Features • • • • • • • • • • • • • • • • • • • • • • • • • • 4WCC3 1½-5 SEER up to............................................................................................................................................................................... 13.00 13.00 HSPF up to................................................................................................................................................................................ 8.25 7.70 Exclusive Duration™ high efficiency compressor with internal overload protection.............................................................. ✔ — Factory supplied charge............................................................................................................................................................ R-410A R-410A Composite Vortica® indoor blower............................................................................................................................................ ✔ ✔ Direct drive multi-speed indoor blower motors.......................................................................................................................... ✔ ✔ All aluminum Spine Fin™ outdoor coil..................................................................................................................................... ✔ ✔ Swept-blade outdoor fan for quiet operation............................................................................................................................. ✔ — Architecturally integrated louvers and corner guards............................................................................................................... ✔ — All steel louvers......................................................................................................................................................................... — ✔ Cabinet constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint............................ ✔ ✔ Single stage cool....................................................................................................................................................................... ✔ ✔ Start kit - factory installed (single phase only).......................................................................................................................... 1½ - 2½ 1½ - 2½ High pressure cutout................................................................................................................................................................. ✔ ✔ Low pressure cutout.................................................................................................................................................................. ✔ ✔ Liquid line drier - factory installed............................................................................................................................................. ✔ ✔ Non-bleed expansion valves on indoor and outdoor coils........................................................................................................ ✔ ✔ Pressure taps, including liquid line taps, easily accessed and protected inside compressor compartment......................................................................................................................................................... ✔ ✔ Right side electrical service access for high and low voltage connections............................................................................... ✔ ✔ Rugged steel basepan features deep drawn duct connections................................................................................................ ✔ ✔ Steeply sloped composite drainpan.......................................................................................................................................... ✔ ✔ Ships in horizontal configuration and converts quickly for downflow........................................................................................ ✔ ✔ Copper tube, aluminum fin indoor coil...................................................................................................................................... ✔ ✔ All models are certified to UL 1995........................................................................................................................................... ✔ ✔ 10-year compressor, 10-year outdoor coil, and 10-year all other functional parts registered limited warranty (Residential Use)1...................................................................................................... ✔ ✔ Extended warranties available............................................................................................................................................... ✔ ✔ 1Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-6 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 1½-5 Tons 4WCX3 4WCC3 1½-51½-5 Table PH-7-A — Accessories Model Number Description Shipping Weight BAYACCDOR1A.............. Hinged Filter Access Doorr .....................................................................................................1½-3 1½-3 BAYACCDOR2A.............. Hinged Filter Access Doorr .....................................................................................................3½-5 3½-5 BAYADAP050A................ Adapter Curb (Cabinet A/B).......................................................................................................1½-3 1½-3 BAYADAP051A................ Adapter Curb (Cabinet C)...........................................................................................................1½-3 1½-3 BAYADAP052A................ Adapter Curb (Cabinet A/B).......................................................................................................3½-5 3½-5 BAYADAP053A................ Adapter Curb (Cabinet C)...........................................................................................................3½-5 3½-5 BAYADAP054A................ Adapter Curb (Cabinet D)...........................................................................................................3½-5 3½-5 BAYASCT001.................. Anti-Short Cycle Timer5 ........................................................................................................... ✔ ✔ BAYCCHT101A............... Crankcase Heater (230V) (Recip.).............................................................................................1½ 1½ BAYCCHT102A............... Crankcase Heater (230V) (Scroll)..............................................................................................2-5 2-5 BAYCCHT404B............... Crankcase Heater (460V) (Scroll)..............................................................................................3-5 3-5 BAYCOVR112A............... 12" Duct Shroud (Covers Horizontal Ducts)8 ...........................................................................1½-5 1½-5 BAYCOVR118A............... 18" Duct Shroud (Covers Horizontal Ducts)8 ...........................................................................1½-5 1½-5 BAYCURB050A............... Flat Roof Full Perimeter Curb (Insulated) .................................................................... 74............. 2-3 1½-3 BAYCURB051A............... Flat Roof Full Perimeter Curb (Insulated) .................................................................... 74.............3½-5 3½-5 BAYDMPR101A.............. 2-Position Motorized Damper290qw ..................................................................................2-3 1½-3 BAYDMPR102A.............. 2-Position Motorized Damper290qw ..................................................................................3½-5 3½-5 BAYECON101A............... Economizer with Barometric Relief (Downflow)1245we ...................................................1½-3 1½-3 BAYECON102A............... Economizer with Barometric Relief (Downflow)1245we ...................................................3½-5 3½-5 BAYECON200A............... Economizer (Horizontal)12459 ..........................................................................................1½-3 1½-3 BAYECON201A .............. Economizer (Horizontal)12459 .........................................................................................3½-5 3½-5 BAYECONCOMB101A....... BAYECON101A, door, and filter kit................................................................................................. 1½-3 1½-3 BAYECONCOMB102A.... BAYECON102A, door, and filter kit ........................................................................................... 3½-5 3½-5 BAYENTH001A............... Enthalpy Control Kit4 ............................................................................................... 2.............. ✔ ✔ BAYEXMK001A............... Extreme Conditions Mounting Kit............................................................................................... ✔ ✔ BAYEXMK002B............... Extreme Conditions Mounting Kit............................................................................................... ✔ ✔ BAYEXMK003A............... Extreme Conditions Mounting Kit (Used on Slab Mounts)......................................................... ✔ ✔ BAYFLTR101C................ 1-2" Filter Frame-Requires one 20x25 filter. (not included)2 .................................... 6..............1½-3 1½-3 BAYFLTR201C................ 1-2" Filter Frame-Requires one 20x20, and one 20x18 filters. (not included)2 ....... 6..............3½-5 3½-5 BAYLIFT002B.................. Lifting Lug Kit ............................................................................................................. 5.............. ✔ ✔ BAYLOAM105A............... Low Ambient Control Kit ............................................................................................ 5.............. ✔ ✔ BAYRLAY004A................ Economizer Relay1................................................................................................................... ✔ ✔ BAYOSAC001B............... Outside Air Control for V.S. Economizert...................................................................................3,4,5 3,4,5 BAYOSAH001A............... Manual Fresh Air Damper2 ...................................................................................... 6..............1½-3 1½-3 BAYOSAH002A............... Manual Fresh Air Damper2 ...................................................................................... 8..............3½-5 3½-5 BAYQSTK300A............... Start Kit.......................................................................................................................................1 Phase Only 1 Phase Only BAYSQRD001A............... 16" Round Duct Adapter7 ....................................................................................... 5..............1½-3 1½-3 BAYSQRD002A............... 18" Round Duct Adapter7 ....................................................................................... 3..............1½-5 1½-5 BAYUTIL101B................. Roof Curb Extension Kit.............................................................................................................1½-3 1½-3 BAYUTIL102B................. Roof Curb Extension Kit.............................................................................................................3½-5 3½-5 BAYUV101A.................... 21" Retrofit UVC Lamp Kit.......................................................................................... 5..............1½-3 1½-3 BAYUV102A.................... 33" Retrofit UVC Lamp Kit.......................................................................................... 5..............3½-5 3½-5 1Relay required with economizer on all heat pump applications. 2Must use filter frame when economizer/fresh air kit is used. EXISTING NEW UNIT USE 3Ships knocked down. CURB 4TC/WC/YC/DC****A BAYADAP0**A 4Dry bulb control standard with economizer. BAYCURB030,38A 018-036 50 52-Stage cooling control required when using economizer. BAYCURB030,38A 018-036 52 6Do not use with electronic thermostats. 7 It is the responsibility of the installing dealer to properly size the BAYCURB030,38A 018-036 51 ductwork for each specific application. BAYCURB030,38A 018-036 53 8 BAYCOVR112,118A will not cover BAYSQRD002A applications. BAYCURB030,38A 018-036 54 9Does not contain barometric relief. 0Max fresh air - 25%. qFor non-continuous fan gas-heating applications, the damper opens only when the OD ambient is above 50° F. wIt is the designer/engineer's responsibility to review product specifications prior to equipment selection to insure optimal performance and compliance to codes. eTemperature of mixed air entering the heat exchanger is monitored and fresh air intake may be reduced under certain conditions. rBAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward compatible to BAYFLTR101/201A. tBAYOSAC001B is not compatible with BAYACCDOR1A or BAYACCDOR2A. For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-7 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 1½-5 Tons Table PH-8-A — Supplementary Heaters – Separate power source /power entry required Model Number Description Used With Shipping Weight BAYHTRV105E BAYHTRV108E BAYHTRV110E BAYHTRV115E BAYHTRV120E BAYHTRV125E BAYHTRV305E BAYHTRV308E BAYHTRV310E BAYHTRV315E BAYHTRV320E BAYHTRV325E BAYHTRV405E BAYHTRV408E BAYHTRV410E BAYHTRV415E BAYHTRV420E 3.76/5.0 kW Heater (208/240V 1PH) 6.0/8.0 kW Heater (208/240V 1PH) 7.50/10.0 kW Heater (208/240V 1PH) 11.27/15.00 kW Heater (208/240V 1PH) 15.0/20.0 kW Heater (208/240V 1PH) 18.78/25.0 kW Heater (208/240V 1PH) 3.76/5.0 kW Heater (208/240V 3PH) 6.0/8.0 kW Heater (208/240V 3PH) 7.50/10.0 kW Heater (208/240V 3PH) 11.27/15.00 kW Heater (208/240V 3PH) 15.00/20.0 kW Heater (208/240V 3PH) 18.78/25.0 kW Heater (208/240V 3PH) 5.0 kW Heater (480V 3PH) 8.0 kW Heater (480V 3PH) 10.0 kW Heater (480V 3PH) 15.00 kW Heater (480V 3PH) 20.0 kW Heater (480V 3PH) 4WC*3018-0601,4024-0601,6036-06019 4WC*3018-0601,4024-0601,6036-060110 4WC*3024-0601,4024-0601,6036-060110 4WC*3030-0601,4030-0601,6036-060114 4WC*3042-0601,4048-0601,6048-060114 4WC*3060A1,40601,6048-060121 4WC*3018-060A3,4036-060A3,6036-060A3 9 4WC*3018-060A3,4036-060A3,6036-060A3 10 4WC*3024-060A3,4036-060A3,6036-060A3 10 4WC*3030-060A3,4036-060A3,6036-060A3 14 4WC*3048-060A3,4048-060A3,6048-060A3 14 4WC*3060A3,4060A3,6048-060A3 20 4WC*3018-060A4,6036-060A4 9 4WC*3018-060A4,6036-060A4 10 4WC*3024-060A4,6036-060A4 10 4WC*3030-060A4,6036-060A4 14 4WC*3048-060A4,6048-060A4 14 BAYHTRV425E 25.0 kW Heater (480V 3PH) 4WC*3060A4,6048-060A4 16 Table PH-8-B — Single Power Entry Kit/Heater Matrix: Single Power Heater Entry Kit1Model Unit Model BAYSPEK060E BAYSPEK061E BAYSPEK062E BAYSPEK063E BAYSPEK064E BAYSPEK065E 4WC*3018-0361, 4WCY4024-0361, 4WCZ603613 4WC*30181, 4WCY40241 4WC*3036-060A3, 4WCY4036-060A3, 4WCZ6036-060A3 7 4WC*3036-060A3, 4WCY4036-060A3, 4WCZ6036-060A3 4WC*3036-048A3, 4WCY4036-060A3, 4WCZ6036-048A3 4WC*3036-060A4, 4WCZ6048-060A4 4WCZ6048-060A4 4WC*3036-060A4, 4WCZ6036-060A4 4WC*3036-060A4, 4WCZ6036-060A4 4WC*3036-048A4, 4WCZ6048-060A4 4WC*3048-0601, 4WCY4048-0601, 4WCZ6048-06017 4WC*3036-0601, 4WCY4036-0601, 4WCZ6036-0601 4WC*3048-0601, 4WCY4024-0601, 4WCZ6036-0601 4WC*3036-0601, 4WCY4036-0601, 4WCZ6036-06017 4WC*3048-0601, 4WCY4048-0601, 4WCZ6048-0601 4WC*3036-060A3, 4WCY4036-060A3, 4WCZ6036-060A3 6 4WC*3048-060A3, 4WCY4048-060A3, 4WCZ6048-060A3 4WC*3060A3, 4WCY4060A3, 4WCZ6060A3 7 BAYHTRV105E BAYHTRV108E BAYHTRV305E BAYHTRV308E BAYHTRV310E BAYHTRV405E BAYHTRV408E BAYHTRV410E BAYHTRV415E BAYHTRV420E BAYHTRV105E BAYHTRV108E BAYHTRV110E BAYHTRV115E BAYHTRV120E BAYHTRV315E BAYHTRV320E BAYHTRV310E Shipping Weight 1All necessary fuses are included in kit; however, not all kits require fuses. Please refer to BAYSPEK Installers Guide. Note: Replace "*" with "C" or "X" as appropriate. Note: Replace "" with "A" or "B" as appropriate. For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-8 Effective 7/1/12 14-1011-28 Packaged Heat Pump Over/Under 2-5 Tons • Duration™ compressor • Over (supply) under (return) air • Compressor sump heat • Compressor internal overload protection • Solenoid operated switchover valve • Demand defrost control system • Multi-speed direct drive blower motor • High efficiency ECM indoor blower motor on 4WHC3042, 048 and 060 models • Weather resistant Powder Paint • Copper tube, aluminum plate fin coils • Top discharge condensing fan • Indoor fan relay • Factory installed wrap-around coil guard • Top access to supplementary heater 4WHC3 Silver SI • Expansion valves • Pressure taps for refrigerant checks • Polarized plug for easy field connection of low voltage to supplementary heaters • 4WHC3030-060 contain high efficiency indoor blower motors • Low ambient cooling to 45°F as manufactured • Low ambient cooling to 0°F with accessory BAYLOAM011A • All models are certified to UL 1995 • 5-year limited warranty on compressor, outdoor coil and all other functional parts (Residential Use) • Optional extended warranties Table PH-9-A — 4WHC3 – Silver SI– Over/Under Horizontal Unit – R-410A Unit Model No. Capacity SEER/EER HSPF 4WHC3024A1000A 4WHC3030A1000A 4WHC3036A1000A 4WHC3042A1000A 4WHC3048A1000A 4WHC3060A1000A Tons 25,400 29,400 35,600 41,500 47,000 60,000 13.5/12 14/12 13/11 13/11 13.5/11 13/10.8 7.7 8 8 7.7 7.7 7.7 DimensionsShipping (in.) Weight H x D x W (lbs.) MCA* 31 x 44 x 32 31 x 44 x 32 31 x 44 x 32 31 x 44 x 32 33 x 58 x 45 33 x 58 x 45 345 345 345 353 520 537 14 19 22 31 37 43 Max Sound Fuse* Rating 20 30 35 50 50 60 76 75 75 77 84 84 Supply H x W Return H x W 2 – 31/283/8 x 273/8163/4 x 273/8 4 – 5 81/2 x321/321915/16 x 321/32 Dimensions are in inches. See Outline Dimensions. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-9 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 3-10 Tons Standard Features: Beveled Top Smoother Design Small compact cabinet Recessed access handles • American Standard Heating & Air Conditioning scroll compressors on all 3-10 ton units • ReliaTel™ Controls (See page PC-16 for ReliaTel™ Control Information) • Thermal Expansion Valve • Colored and numbered wiring • Phase Monitor, R-410A, 3 Phase Units • Provisions for through the Base Condensate Drain Connections • Patented Hybrid Condenser Coil for easy cleaning • 2" throwaway filters provided on 3-10 ton units • Liquid Line Refrigerant Drier • Operating Charge of R-410A • IAQ Sloped Drain Pans • Single point power for electric Heat • Low Ambient cooling to 0°F • Anti-Short Cycle Timer (Standard with ReliaTel™) • 5 - year Limited Compressor Warranty • 1 - year Limited Parts Warranty Added Flexibility • Convertible airflow • Fork lift openings on three sides of unit • Direct or belt drive - standard or oversized motors (Direct for 3-5 ton only) • We don’t prepackage options • Choose options tailored to suit each job —pay only for what is needed • Units ship with options installed —and within our standard ship cycle time Factory Installed Options • Through-the-Base — Electrical • Convenience Outlet — Powered or unpowered • Unit Disconnect Switch • Circuit Breaker • Smoke Detectors — Supply, return, or both • Condenser Coil Coating • Hinged Access Service Panels • Discharge Air Sensor • Fan Fail and Clogged Filter Switches • Condenser Coil Guard — Hail Protection Quality • Comm 3/4 Communication Interface • Frostat • 2" MERV 8 filters or 2" MERV 13 filters • Black Epoxy Pre-Coated Coils • Crankcase Heaters1 • Multi-Speed & Single Zone VAV ID Airflow 1 Crankcase heaters are optional on WSC036E1, WSC048E1, WSC060E1. The same American Standard Heating & Air Conditioning Quality and Reliability … with added Flexibility! For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-10 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 3-10 Tons Table PH-11-A — Base Unit — Standard Efficiency — ReliaTel™ Microprocessor Controls Unit Performance2 Tons Ordering No. SEER/EER Cooling Cabinet Capacity Dimensions (in.) Downflow Downflow (Btuh) H x D x W Supply Return Shipping Weight (Ibs.) MCA* WSC – 208-230/1/60 – Single Phase – No Heat 3 WSC036E1R0A0000 13.0 37,650 36 x 43 x 69 16 x 15.5 24 x 14 589 31.2 4 WSC048E1R0A0000 13.0 49,040 36 x 43 x 69 16 x 15.5 24 x 14 600 38.9 5 WSC060E1R0A0000 13.0 58,360 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 44.6 WSC – 208-230/3/60 – Three Phase – No Heat 3 WSC036E3R0A0000 13.0 38,030 36 x 43 x 69 16 x 15.5 24 x 14 589 23.8 4 WSC048E3R0A0000 13.0 50,130 36 x 43 x 69 16 x 15.5 24 x 14 600 27.5 5 WSC060E3R0A0000 13.0 63,440 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 30.2 6 WSC072E3*0A0000 11.4 78,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 835 36.3 7½ WSC090E3*0A0000 11.1 94,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 902 38.4 10 WSC120E3*0A0000 11.2 126,000 51 x 63 x 100 33 x 17.5 32.25 x 17.5 1388 51.9 WSC – 460/3/60 – Three Phase – No Heat 3 WSC036E4R0A0000 13.0 38,030 36 x 43 x 69 16 x 15.5 24 x 14 589 11.4 4 WSC048E4R0A0000 13.0 50,130 36 x 43 x 69 16 x 15.5 24 x 14 600 12.3 5 WSC060E4R0A0000 13.0 63,440 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 14.7 6 WSC072E4*0A0000 11.4 78,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 835 20.3 7½ WSC090E4*0A0000 11.1 94,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 902 19 10 WSC120E4*0A0000 11.2 126,000 51 x 63 x 100 33 x 17.5 32.25 x 17.5 1388 26.1 WSC – 575/3/60 – Three Phase – No Heat 3 WSC036EWR0A0000 13.0 38,030 36 x 43 x 69 16 x 15.5 24 x 14 589 8.8 4 WSC048EWR0A0000 13.0 50,130 36 x 43 x 69 16 x 15.5 24 x 14 600 9.5 5 WSC060EWR0A0000 13.0 63,440 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 11.0 6 WSC072EW0A0000 11.4 78,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 835 12.4 7½ WSC090EW0A0000 11.1 94,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 902 14.5 10 WSC120EW0A0000 11.2 126,000 51 x 63 x 100 33 x 17.5 32.25 x 17.5 1388 21.1 Max1 Fuse* 45 60 70 35 40 45 50 60 60 15 15 20 30 30 35 15 15 15 20 20 25 * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. 1 HCAR breaker per NEC. 2 SEER applies, 3-5 tons; EER applies 6-10 tons. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-11 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 3-10 Tons (Model Digit Numbers) Digit Description Digit Order Number 1Economizer with Barometric Relief is for downfllow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must be ordered as field installed accessory BAYBARM010A. 2 Requires use of Disconnect or Circuit Breaker. 3 Standard refrigeration metering device - short orifice. 4Not available with BAYFRST003A High Temperature Stat accessory. 5The return air smoke detector may not fit up or work properly on the Convertible units when used in conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not order the return air smoke detectors when using this type of accessory. Heaters (Digit 10) kW Nominal No. Rating Digit BTUH Stages Used With 208/240/1/60 3.8/5.0 7.5/10.0 10.4/13.8 13.2/17.6 208/240/3/60 4.5/6.0 9.0/12.0 13.1/17.4 17.3/23.0 6.75/9.0 13.5/18.0 20.3/27.0 27.0/36.0 40.5/54.0 (A) (D) (F) (G) 12,800/17,100 25,600/34,100 35,300/47,100 45,100/60,100 1 2 2 2 WSC036-060E1 WSC036-060E1 WSC036-060E1 WSC048-060E1 (B) (E) (G) (J) (C) (G) (K) (N) (P) 13,400/20,500 30,800/59,400 44,600/59,400 58,900/78,500 23,000/30,700 46,100/61,400 69,000/92,100 92,200/122,900 138,200/184,300 1 2 2 2 1 1 2 2 2 WSC036-060E3 WSC036-060E3 WSC036-060E3 WSC060E3 W*C072-090E3 W*C072-120E3 W*C072-120E3 W*C072-120E3 W*C120E3 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. Description Order Number 18 Through the Base Provisions No Through the Base Provisions.................................... 0 Through the Base Electric6 ........................................... A 19 Disconnect/Circuit Breaker8 (3 phase only) No Disconnect /Circuit Breaker/No Phase Monitor......... 0 Unit Mounted Non-Fused Disconnect6 ......................... 1 Unit Mounted Circuit Breaker6 ...................................... 2 20 Convenience Outlet No Convenience Outlet................................................... 0 Unpowered Convenience Outlet..................................... A Powered Convenience Outlet (3 phase only)2 .............. B 21 Communications Options No Communications Interface......................................... 0 Comm 3/4 Communications Interface............................. 1 22 Refrigeration System Option3 Standard Refrigeration System....................................... 0 23 Refrigeration Controls No Refrigeration Control ................................................ 0 Frostat ........................................................................... 2 Crankcase Heater .......................................................... 3 Frostat and Crankcase Heater........................................ 6 24 Smoke Detector45 No Smoke Detector........................................................ 0 Return Air Smoke Detector ............................................ A Supply Air Smoke Detector............................................. B Supply and Return Air Smoke Detectors ...................... C 25 Monitoring Controls No Monitoring Control .................................................... 0 Clogged Filter Switch...................................................... 1 Fan Failure Switch ......................................................... 2 Discharge Air Sensing Tube ........................................... 3 Clogged Filter Switch and Fan Fail Switch ..................... 4 Clogged Filter Switch and Discharge Air Sensing Tube ......................................................... 5 Fan Fail Switch and Discharge Air Sensing Tube ........... 6 Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tube ................................. 7 1-8 Main Assembly (see previous page) 9 Unit Controls ReliaTel™ Micro-processor............................................. R 10 (See Heater Table below) 11 Minor Design Sequence First Sequence.............................................................. A 12-13 Service Sequence First Sequence (Factory Assiged)................................. ✱,✱ 14 Fresh Air Selection No Fresh Air.................................................................... 0 0-50% Manual Outside Air Damper7............................. A 0-50% Motorized Outside Air Damper............................ B 0-100% Economizer, Dry Bulb without Barometric Relief 1 .................................................... C 0-100% Economizer, Dry Bulb with Barometric Relief1 ................................................... D 0-100% Economizer, Reference Enthalpy without Barometric Relief1 ......................................... E 0-100%Economizer, Reference Enthalpy with Barometric Relief1 ............................................. F 0-100%Economizer, Comparative Enthalpy without Barometric Relief 1 ..................................G 0-100%Economizer, Comparative Enthalpy with Barometric Relief 1 ............................................ H 15 Supply Fan/Drive Type/Motor Standard Drive................................................................ 0 Oversized Motor............................................................. 1 Optional Belt Drive Motor (3 phase only)........................ 2 16 Hinged Service Access & Filters Standard Panels & Filters............................................... 0 Hinged Access Panels & Standard Filters...................... A Standard Panels & 2" Pleated Filters MERV 7................ B Hinged Access Panels & 2" Pleated Filters MERV 7...... C Standard Panels & 2" Pleated Filters MERV 13.............. D Hinged Access Panels & 2" Pleated Filters MERV 13.... E 17 Condenser Coil Protection Standard Coil ................................................................. 0 Standard Coil with Hail Guard........................................ 1 Black Epoxy Pre-Coated Condenser Coil....................... 2 Black Epoxy Coated Pre-Condenser Coil with Hail Guard............................................................. 3 6Through the base electric required when ordering disconnect/circuit breaker options. 7The manual outside air damper will ship factory supplied within the unit, but must be field installed. 8Phase Monitor is standard on all R-410A 3 Phase models. kW Nominal No. Rating Digit BTUH Stages Used With 460/3/60 6.0 12.0 17.4 23.0 9.0 18.0 27.0 36.0 54.0 575/3/60 6.0 12.0 17.4 23.0 9.0 18.0 27.0 36.0 54.0 PH-12 (B) (E) (G) (J) (C) (G) (K) (N) (P) 20,500 41,000 59,400 78,500 30,700 61,400 92,100 122,900 184,300 1 2 2 2 1 1 2 2 2 WSC036-060E4 WSC036-060E4 WSC036-060E4 WSC060E4 W*C072-090E4 W*C072-120E4 W*C072-120E4 W*C072-120E4 W*C120E4 (B) (E) (G) (J) (C) (G) (K) (N) (P) 20,500 41,000 59,400 78,500 30,700 61,400 92,100 122,900 184,300 1 2 2 2 1 1 2 2 2 WSC036-060EW WSC036-060EW WSC036-060EW WSC060EW W*C072-090EW W*C072-120EW W*C072-120EW W*C072-120EW W*C120EW Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 3-5 Tons, Electric Heaters Table PH-13-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entry Model Number Power Supply kW Rating Nominal BTUH No. Stages BAYHTRE105A BAYHTRE110A BAYHTRE114A BAYHTRE118A 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 3.8/5.0 7.5/10.0 10.4/13.8 13.2/17.6 12,900/13,400 25,600/34,000 35,000/47,100 45,100/60,100 1 2 2 2 Used With WSC036-048E1 WSC036-048E1 WSC036-048E1 WSC048E1 BAYHTRE306B BAYHTRE312B BAYHTRE318B 208-230/3/60 208-230/3/60 208-230/3/60 4.5/6.0 9.0/12.0 13.0/17.4 13,400/20,500 30,800/41,000 44,600/59,400 1 2 2 WSC036-048E3 WSC036-048E3 WSC036-048E3 BAYHTRE406B BAYHTRE412B BAYHTRE418B 460/3/60 460/3/60 460/3/60 6.0 12.0 17.4 20,500 41,000 59,400 1 2 2 WSC036-048E4 WSC036-048E4 WSC036-048E4 BAYHTREW06B BAYHTREW12B BAYHTREW18B 575/3/60 575/3/60 575/3/60 6.0 12.0 17.4 20,500 41,000 59,400 1 2 2 WSC036-048EW WSC036-048EW WSC036-048EW Table PH-13-B — Accessory Electric Heaters – Unit with heater is single circuit / single point power entry (5 Ton Only) Model Number Power Supply kW Rating Nominal BTUH No. Stages BAYHTRX105A BAYHTRX110A BAYHTRX114A BAYHTRX118A 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 3.8/5.0 7.5/10.0 10.4/13.8 13.2/17.6 12,900/13,400 25,600/34,000 35,000/47,100 45,100/60,100 1 2 2 2 Used With WSC060E1 WSC060E1 WSC060E1 WSC060E1 BAYHTRX306B BAYHTRX312B BAYHTRX318B BAYHTRX323B 208-230/1/60 208-230/3/60 208-230/3/60 208-230/3/60 4.5/6.0 9.0/12.0 13.0/17.4 17.3/23.0 13,400/20,500 30,800/41,000 44,600/59,400 59,000/78,500 1 2 2 2 WSC060E3 WSC060E3 WSC060E3 WSC060E3 BAYHTRX406B BAYHTRX412B BAYHTRX418B BAYHTRX423B 460/3/60 460/3/60 460/3/60 460/3/60 6.0 12.0 18.0 23.0 20,500 41,000 59,400 78,500 1 2 2 2 WSC060E4 WSC060E4 WSC060E4 WSC060E4 BAYHTRXW06B BAYHTRXW12B BAYHTRXW18B BAYHTRXW23B 575/3/60 575/3/60 575/3/60 575/3/60 6.0 12.0 18.0 23.0 20,500 41,000 59,400 78,500 1 2 2 2 WSC060EW WSC060EW WSC060EW WSC060EW For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-13 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 6-10 Tons, Electric Heaters and Zone Sensors Table PH-14-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entry Model Number Power Supply kW Rating Nominal BTUH No. Stages Used With BAYHTRW309A 208-230/3/60 6.8/9.0 23,000/30,700 1 WSC072E3 BAYHTRW318A 208-230/3/60 13.5/18.0 46,100/61,400 1 WSC072E3 BAYHTRW327A 208-230/3/60 20.3/27.0 69,000/92,100 2 WSC072E3 BAYHTRW336A 208-230/3/60 27.0/36.0 92,100/122,900 2 WSC072E3 BAYHTRU309A 208-230/3/60 6.8/9.0 23,000/30,700 1 WSC090E3 BAYHTRU318A 208-230/3/60 13.5/18.0 46,100/61,400 1 WSC090E3 BAYHTRU327A 208-230/3/60 20.3/27.0 69,000/92,100 2 WSC090E3 BAYHTRU336A 208-230/3/60 27.0/36.0 92,100/122,900 2 WSC090E3 BAYHTRB318A 208-230/3/60 13.5/18.0 46,100/61,400 1 WSC120E3 BAYHTRB327A 208-230/3/60 20.3/27.0 69,000/92,100 2 WSC120E3 BAYHTRB336A 208-230/3/60 27.0/36.0 92,100/122,900 2 WSC120E3 BAYHTRB354A 208-230/3/60 40.6/54.0 138,000/184,300 2 WSC120E BAYHTRW409A 460/3/60 9.0 30,700 1 WSC072E4 BAYHTRW418A 460/3/60 18.0 61,400 1 WSC072E4 BAYHTRW427A 460/3/60 27.0 92,100 2 WSC072E4 BAYHTRW436A 460/3/60 36.0 122,900 2 WSC072E4 BAYHTRU409A 460/3/60 9.0 30,700 1 WSC090E4 BAYHTRU418A 460/3/60 18.0 61,400 1 WSC090E4 BAYHTRU427A 460/3/60 27.0 92,100 2 WSC090E4 BAYHTRU436A 460/3/60 36.0 122,900 2 WSC090E4 BAYHTRB418A 460/3/60 18.0 61,400 1 WSC120E4 BAYHTRB427A 460/3/60 27.0 92,100 2 WSC120E4 BAYHTRB436A 460/3/60 36.0 122,900 2 WSC120E4 BAYHTRB454A 460/3/60 54.0 184,300 2 WSC120E4 BAYHTRWW18A 575/3/60 18.0 61,400 1 WSC072EW BAYHTRWW27A 575/3/60 27.0 92,100 2 WSC072EW BAYHTRWW36A 575/3/60 36.0 122,900 2 WSC072EW BAYHTRUW18A 575/3/60 18.0 61,400 1 WSC090EW BAYHTRUW27A 575/3/60 27.0 92,100 2 WSC090EW BAYHTRUW36A 575/3/60 36.0 122,900 2 WSC090EW BAYHTRBW18A 575/3/60 18.0 61,400 1 WSC120EW BAYHTRBW36A 575/3/60 36.0 122,900 2 WSC120EW BAYHTRBW54A 575/3/60 54.0 184,300 2 WSC120EW Table PH-14-B — Zone Sensors for ReliaTel™ Controlled Units Model Number Description Used With BAYMTPL103A ASYSTAT107A ASYSTAT109A ASYSTAT111A ASYSTAT777A ASYSTAT777A WSC036-120E WSC036-120E ASYSTAT777A WSC036-120E Retrofit Wall Cover Plate Kit 7.25" x 6.0" Single Setpoint Manual Changeover Dual Setpoint Manual or Auto Changeover Remote Room Sensor Programmable Night Setback w/System Function Lights (Vertical Style) For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-14 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 3-10 Tons Accessories Table PH-15-A — Accessories Model Number Description Used With BAYABRD001C4..................... ReliaTel™ Options Module............................................All WSC036-120E, See Note4 BAYBARM010A2 ................... Barometric Relief...........................................................WSC036-048E BAYBARM011A2.................... Barometric Relief...........................................................WSC060-120E BAYBCIR001A......................... Bacnet™ Communication Interface...............................ReliaTel™ Controller (BCI-R) BAYCCHT010B........................ Crankcase Heater..........................................................WSC036E1, E3, WSC048E1 BAYCCHT011B........................ Crankcase Heater..........................................................WSC036E4, EW BAYCCHT017A........................ Crankcase Heater..........................................................WSC060E1 ASYSTAT712B......................... CO2 Sensor Kit, Wall Mounted.......................................All WSC036-120E ASYSTAT714B......................... CO2 Sensor Kit, Duct Mounted......................................All WSC036-120E BAYCURB042A3.................... Roof Curb......................................................................WSC036-048E BAYCURB043A3.................... Roof Curb......................................................................WSC060-090E BAYCURB044A3.................... Roof Curb......................................................................WSC120E BAYDFPS003B4..................... Clogged Filter Switch (w/Standard & MERV 7 Filter)....All WSC036-120E BAYDFPS014A4..................... Clogged Filter Switch (MERV 13 Filter).........................All WSC036-120E BAYDFPS004A4..................... Fan Failure Switch.........................................................All WSC036-120E BAYDMPR053B6.................... 0-50% Manual Outside Air Damper...............................WSC036-048E BAYDMPR056B6.................... 0-50% Manual Outside Air Damper...............................WSC060-120E BAYDMPR051A....................... 0-50% Motorized Outside Air Damper...........................WSC036-048E BAYDMPR054A....................... 0-50% Motorized Outside Air Damper...........................WSC060-120E BAYECON085A........................ 0-100% Economizer without Barometric Relief.............WSC036-048E BAYECON087A........................ 0-100% Economizer without Barometric Relief.............WSC060-120E BAYENTH005A1..................... Reference Enthalpy Kit..................................................BAYECON085A, 087A BAYENTH006A1..................... Comparative Enthalpy Kit..............................................BAYECON085A, 087A BAYFRST003A5 .................... High Temperature Stat...................................................All WSC036-120E BAYGARD037B........................ Condenser Coil Hail Guard............................................WSC036-048E BAYGARD040A........................ Condenser Coil Hail Guard............................................WSC060E-072E BAYGARD041A........................ Condenser Coil Hail Guard............................................WSC090E BAYGARD070A........................ Condenser Coil Hail Guard............................................WSC120E 1Kits contain all necessary parts to achieve desired level of enthalpy control. 2Barometric Relief accessory installs in ductwork for horizontal configuration. For downflow configuration, installs in the unit's horizontal return duct. See Installer's Guide for complete instructions. 3Lynn Haven manufacturing has a no return policy for this roof curb. 4BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit (BAYTUBE005A or BAYTUBE007A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) Ventilation Override Kit (BAYVNOR001B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options Include the ReliaTel™ Options Module. 5Cannot be used in conjunction with factory installed smoke detector. 6The manual outside air damper will ship factory supplied within the unit, but must be field installed. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-15 Effective 7/1/12 14-1011-28 Packaged Heat Pump Convertible 3-10 Tons Accessories Table PH-16-A — Accessories Model Number Description Used With BAYHSMT403A........................ 2 HP Belt Drive Oversized Motor ..................................WSC072E3, E4 BAYHSMT404A........................ 2 HP Belt Drive Oversized Motor ..................................WSC072EW BAYHSMT400A........................ 3 HP Belt Drive Oversized Motor ..................................WSC090E3, E4 BAYHSMT401A........................ 3 HP Belt Drive Oversized Motor ..................................WSC090EW BAYLSDR009A........................ Low Static Drive.............................................................WSC090E* BAYKSKT255B......................... Start Kit.......................................................................... WSC036-060E1 BAYPWRX070A....................... Power Exhaust (208-230/3)...........................................WSC036-060E3 BAYPWRX071A....................... Power Exhaust (460/3)..................................................WSC036-060E4 BAYPWRX072A....................... Power Exhaust (575/3)..................................................WSC036-060EW BAYPWRX026A6.................... Power Exhaust (208-230/3)...........................................WSC072-120E3 BAYPWRX027A6.................... Power Exhaust (460/3)..................................................WSC072-120E4 BAYPWRX028A6.................... Power Exhaust (575/3)..................................................WSC072-120EW BAYQACB009A23................. Quick Adapt Roof Curb..................................................WSC036-048E BAYQACB010A23................. Quick Adapt Roof Curb..................................................WSC036-048E BAYQACB011A28................. Quick Adapt Roof Curb..................................................WSC060-090E BAYQACB012A28................. Quick Adapt Roof Curb .................................................WSC060-090E BAYQACB013A28................. Quick Adapt Roof Curb .................................................WSC060-090E BAYQACB111A23................. Quick Adapt Roof Curb..................................................WSC120E BAYQACB112A23................. Quick Adapt Roof Curb..................................................WSC120E BAYQACB113A23................. Quick Adapt Roof Curb..................................................WSC120E BAYRTEM001A8 ................... Fully Featured ReliaTel™ Economizer Logic Model......WSE036-120E BAYSENS016A........................ Duct Temperature Sensor..............................................WSC036-120E BAYSERV001A........................ Selective Resistance Service Tester..............................All WSC036-120E BAYSTAT023............................ Remote Potentiometer...................................................All WSC036-120E BAYTUBE005A14................. Discharge Air Sensing Kit..............................................WSC036-048E BAYTUBE007A14................. Discharge Air Sensing Kit..............................................WSC060-090E BAYTUBE403A14................. Discharge Air Sensing Kit..............................................WSC120E BAYVNOR001B94................. Ventilation Override Kit w/ReliaTel™ options module....All WSC036-120E 1Used for true discharge air sensing in both heating and cooling. Required for supply air tempering. 2Lynn Haven manufacturing has a no return policy for this roof curb. 3BAYQACB009A adapts WCD models BAYCURB021A roof curb to accept WSC036-048 units. BAYQACB010A adapts WCD models BAYCURB022A roof curb to accept WSC036-048 units. BAYQACB111A adapts WCD models BAYCURB022 roof curb to accept WSC120E. BAYQACB112A adapts WCD models BAYCURB025 roof curb to accept WSC120E. BAYQACB113A adapts WCD models BAYCURB026 roof curb to accept WSC120E. 4BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit (BAYTUBE005A or BAYTUBE007A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) Ventilation Override Kit (BAYVNOR001B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options Include the ReliaTel™ Options Module. 5Power Exhaust cannot be used with Barometric Relief. Order Economizer without Barometric Relief. 6BAYQACB012A adapts WCD models BAYCURB025 roof curb to accept WSC072-120 units.BAYQACB011A adapts WCD models BAYCURB022B roof curb to accept WSC072-120 units. 7BAYQACB013A adapts WCD models BAYCURB026 roof curb to accept WSC060-090E. Field installed accessory. Requires an economizer. 8If any version of comparative or reference enthalpy is ordered, BAYRTEM001A does not need to be ordered. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-16 Effective 7/1/12 14-1011-28 Packaged Heat Pump with ReliaTel™ Controls 12½-20 Tons • EER up to 10.6 • ReliaTel™ processor control features are listed on page PC-16 • Built-in anti-short cycle, time-delay relay and minimum on time controls • 2" filters for 12½ - 20 ton units • Liquid line drier • Built-in fork lift holes • Operating charge of R-410A • Quick-Sess service panels slide in and out • Scroll compressors • Dedicated horizontal and downflow designs • Single-side access 12½ – 20 Ton WCD—Downflow 12½ – 20 Ton WCH—Horizontal • Single point power for electric heat • Complete line of optional electric heaters • Internally enhanced coil tubing • Low ambient to 0°F standard • Colored and numbered wiring • Common cabinet and accessories as TCD/TCH and YCD/YCH models • Quick-adjust idler arm pulley • 5-year limited compressor warranty (12½ – 15 tons) • 1-year limited parts warranty • 1-year limited compressor warranty (20 tons) Table PH-17-A — WCD Downflow — WCH Horizontal — ReliaTel™ Unit (R-410A) Tons Unit Model No. Power Supply Volts/Phase/Hz Performance Cooling EER Capacity (Btuh) Dimensions (in.) H x W x L Shipping Weight (Ibs.) MCA5 Max Fuse Size or4Downflow Max Circuit Breaker Roofcurb 121/2 WC*150E300B 208-230/3/60 15 WC*180E300B 208-230/3/60 20 WC*240E300B 208-230/3/60 10.6 10.6 9.7 148,000 54 x 855/16 x 1225/16 2340 177,000 54 x 855/16 x 1225/16 2435 249,000 641/8 x 855/16 x 1225/16 2566 68 74 116 80 90 150 BAYCURB027B BAYCURB027B BAYCURB027B 121/2 WC*150E400B 15 WC*180E400B 20 WC*240E400B 460/3/60 460/3/60 460/3/60 10.6 10.6 9.7 148,000 54 x 855/16 x 1225/16 2340 177,000 54 x 855/16 x 1225/16 2435 249,000 641/8 x 855/16 x 1225/16 2566 32 36 53 40 45 60 BAYCURB027B BAYCURB027B BAYCURB027B 121/2 WC*150EW00B 15 WC*180EW00B 20 WC*240EW00B 575/3/60 575/3/60 575/3/60 10.6 10.6 9.7 148,000 54 x 855/16 x 1225/16 2340 177,000 54 x 855/16 x 1225/16 2435 249,000 641/8 x 855/16 x 1225/16 2566 25 30 45 30 35 60 BAYCURB027B BAYCURB027B BAYCURB027B Tons Supply Downflow W x L12 Return Downflow W x L12 20289/16 x 691/2221/4 x 77 Supply Horizontal H x W12 Return Horizontal H x W12 Curb Size H x W x L23 Roof Opening W x L12 467/16 x 261/2467/16 x 279/16141/16 x 81 x 1173/16761/2 x 81 Table PH-17-B — WCD Downflow — WCH Horizontal — ReliaTel™ Unit (R-410A) — Multi-Speed Indoor Fan Tons Unit Model No. Power Supply Volts/Phase/Hz Performance Cooling EER Capacity (Btuh) Dimensions (in.) H x W x L Shipping Weight (Ibs.) MCA5 Max Fuse Size or4Downflow Max Circuit Breaker Roofcurb 121/2 WC*150E3A0A 208-230/3/60 15 WC*180E3A0A 208-230/3/60 20 WC*240E3A0A 208-230/3/60 10.6 10.6 9.7 148,000 54 x 855/16 x 1225/16 2365 177,000 54 x 855/16 x 1225/16 2460 249,000 641/8 x 855/16 x 1225/16 2591 68 74 116 80 90 150 BAYCURB027B BAYCURB027B BAYCURB027B 121/2 WC*150E4A0A 15 WC*180E4A0A 20 WC*240E4A0A 460/3/60 460/3/60 460/3/60 10.6 10.6 9.7 148,000 54 x 855/16 x 1225/16 2365 177,000 54 x 855/16 x 1225/16 2460 249,000 641/8 x 855/16 x 1225/16 2591 32 36 53 40 45 60 BAYCURB027B BAYCURB027B BAYCURB027B 121/2 WC*150EWA0A 15 WC*180EWA0A 20 WC*240EWA0A 575/3/60 575/3/60 575/3/60 10.6 10.6 9.7 148,000 54 x 855/16 x 1225/16 2365 177,000 54 x 855/16 x 1225/16 2460 249,000 641/8 x 855/16 x 1225/16 2591 25 30 45 30 35 60 BAYCURB027B BAYCURB027B BAYCURB027B 1Dimensions are in inches. See Outline Dimensions. 2Interior Dimension. 3Measurement Includes Curb Flange. 4HACR type circuit breaker per NEC. 5Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. * Digit 3 - H = Horizontal or D = Downflow. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-17 Effective 7/1/12 14-1011-28 Packaged Heat Pump with ReliaTel™ Controls 12½-20 Tons FIOPS and Zone Sensors Table PH-18-A — Factory Installed Accessories1 For Complete list of all Factory Installed Options, please refer to the FIOPS section of this book. Digit Description 1-8 9-10 11-12 Main Assembly (see previous page) Factory Installed Options No Options Downflow Economizer Oversized Motor Downflow Economizer and Oversized Motor Minor Design and Service Sequence Order Number 00 0A 0B 0C ** Used With WC*150-240 WCD150-240 WC*150-240 WCD150-240 1Price includes accessory and factory installation. 2Four (4) week shipping approximately. 3Some field set up required. Table PH-18-B — Zone Sensors Model Number Description Used With ASYSTAT107A ASYSTAT109A ASYSTAT111A ASYSTAT777A BAYMTPL110A Single Setpoint Manual Changeover Dual Setpoint Manual or Automatic Changeover Remote Room Sensor Programmable Night Setback Retrofit Wall Cover Plate Kit 7.25" x 6.0" WC*150-240 WC*150-240 ASYSTAT777A WC*150-240 ASYSTAT777A For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-18 Effective 7/1/12 14-1011-28 Packaged Heat Pump with ReliaTel™ Controls 12½-20 Tons Accessories Table PH-19-A — Field Installed Accessories — For complete list of of All Factory Installed Options refer to FIOPS section of this book. Model Number Description Used With BAYABRD002B6........... ReliaTel™ Options Module.................................................WC*150E, WC*240E BAYBCIR001A................ Bacnet™ Communication Interface.................................... ReliaTel™ Controller (BCI-R) ASYSTAT713B7........... CO2 Sensor Wall Mounted..................................................WC*150E, WC*240E w/Economizer ASYSTAT715B7........... CO2 Sensor Duct Mounted.................................................WC*150E, WC*240E w/Economizer BAYCURB027B34........Downflow Only Roof Curb .................................................... WCD150E-WCD240E BAYDFPS005A56........Clogged Filter Switch (MERV 7)........................................... WC*150E-WC*240E BAYDFPS006A56........Fan Failure Switch................................................................. WC*150E-WC*240E BAYDFPS013A...............Clogged Filter Switch (MERV 13)......................................... WC*150E-WC*240E BAYDMPR029C..............0-25% Manual Outside Air Damper...................................... All Packaged Rooftops 12½-20 Tons BAYDMPR058A..............0-50% Motorized Outside Air Damper.................................. WC*150E-WC*240E BAYECON090A6...........Downflow Economizer with Barometric Relief...................... WCD150E-WCD240E BAYECON092A...............Horizontal Economizer ......................................................... WCH150E-WCH240E BAYENTH007A.............. Reference Enthalpy Kit.......................................................All BAYECON089-92A BAYENTH008A.............. Comparative Enthalpy Kit...................................................All BAYECON089-92A BAYFRST003A.............. High Temperature Stat.......................................................WC*150E-WC*240E BAYGARD045A6...........Tool-less Hail Guard.............................................................. WC*150E, WC*180E BAYGARD050A6...........Tool-less Hail Guard.............................................................. WC*240E BAYHSDR005B1...........High Static Drive................................................................... WC*150E, WC*180E, WC*240E BAYHSMT055B...............5HP Oversized Motor Kit (208-230/460)..................... WC*150E, WC*180E BAYHSMT072A...............5HP Oversized Motor Kit (575)................................... WC*150E, WC*180E BAYHSMT100A...............7.5HP Oversized Motor Kit (208-230)......................... .WC*240E BAYHSMT101A...............7.5HP Oversized Motor Kit (460)................................ WC*240E BAYHSMT102A...............7.5HP Oversized Motor Kit (575)................................ WC*240E BAYLOAM023A56........Evaporator Defrost Control (Frostat)..................................... WC*150E, WC*180E BAYLOAM031A...............Evaporator Defrost Control................................................... WC*240E BAYLSDR004A...............Low Static Drive.................................................................... WC*240E BAYLSDR011A...............Low Static Drive.................................................................... WC*150E, WC*180E BAYPWRX029A............. Power Exhaust for all 12½-20 Ton 230V units....................Downflow Only BAYPWRX030A............. Power Exhaust for all 12½-20 Ton 460V units....................Downflow Only BAYPWRX031A............. Power Exhaust for all 12½-20 Ton 575V units....................Downflow Only BAYQACB044A...............Adapter Curb......................................................................... BAYCURB026A/B to BAYCURB027A/B BAYSERV001A...............Selective Resistance Service Tester..................................... All 12½-20 Tons BAYSTAT023................... Remote Potentiometer......................................................All BAYECON089-92A BAYTUBE008A256.....Discharge Air Sensing Kit..................................................... WCD150E-WCD240E BAYTUBE009A256.....Discharge Air Sensing Kit..................................................... WCH150E-WCH240E BAYVNOR002B5.......... Ventilation Override Kit.......................................................WCH150-240 w/ReliaTel™ Options Module 1High static drive and oversized motors are mutually exclusive, Do not Combine. 2Used for true discharge air sensing in both heating and cooling models. 3Clarksville Manufacturing has a no-return policy for this roof curb. 4For downflow use only. Can not be adapted for horizontal units. 5BAYABRD002B is required when ordering field installed accessories BAYDFPS005A or 006A, BAYTUBE008A or 009A and BAYLOAM023A, BAYLOAM031A or BAYVNOR002B. 6Field or factory installed option. 7Field installed accessory. Requires an economizer. * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-19 Effective 7/1/12 14-1011-28 Packaged Heat Pump with ReliaTel™ Controls 12½-20 Tons Heaters Table PH-20-A — Downflow Supplementary Heaters: Model Number Power Supply kW Rating BTUH NominalNo. Stages Used With AYDHTRK318A AYDHTRK336A AYDHTRK354A 208-230/3/60 208-230/3/60 208-230/3/60 13.5/18.0 27.0/36.0 40.5/54.0 46,100/61,400 92,200/122,900 138,200/184,300 1 2 2 WCD150E-WCD180E WCD150E-WCD180E WCD150E-WCD180E AYDHTRK418A AYDHTRK436A AYDHTRK454A 460/3/60 460/3/60 460/3/60 18.0 36.0 54.0 61,400 122,900 184,300 1 2 2 WCD150E-WCD180E WCD150E-WCD180E WCD150E-WCD180E AYDHTRL336A AYDHTRL354A AYDHTRK372A 208-230/3/60 208-230/3/60 208-230/3/60 27.0/36.0 40.5/54.0 54.0/72.0 92,200/122,900 138,200/184,300 184,300/245,700 2 2 2 WCD240E WCD240E WCD240E AYDHTRL436A AYDHTRL454A AYDHTRK472A 460/3/60 460/3/60 460/3/60 36.0 54.0 72.0 122,900 184,300 245,700 2 2 2 WCD240E WCD240E WCD240E AYDHTRKW18A AYDHTRKW36A AYDHTRKW54A 575/3/60 575/3/60 575/3/60 18.0 36.0 54.0 61,400 122,900 184,300 1 2 2 WCD150E-WCD180E WCD150E-WCD180E WCD150E-WCD180E AYDHTRLW36A AYDHTRLW54A AYDHTRKW72A 575/3/60 575/3/60 575/3/60 36.0 54.0 72.0 122,900 184,300 245,700 2 2 2 WCD240E WCD240E WCD240E Table PH-20-B — Horizontal Supplementary Heaters: AYHHTRM318A AYHHTRM336A AYHHTRM354A 208-230/3/60 208-230/3/60 208-230/3/60 13.5/18.0 27.0/36.0 40.5/54.0 46,100/61,400 92,200/122,900 138,200/184,300 1 2 2 WCH150E-WCH180E WCH150E-WCH180E WCH150E-WCH180E AYHHTRM418A AYHHTRP436A AYHHTRM454A 460/3/60 460/3/60 460/3/60 18.0 36.0 54.0 61,400 122,900 184,300 1 2 2 WCH150E-WCH180E WCH150E-WCH180E WCH150E-WCH180E AYHHTRN336A AYHHTRN354A AYHHTRN372A 208-230/3/60 208-230/3/60 208-230/3/60 27.0/36.0 40.5/54.0 54.0/72.0 92,200/122,900 138,200/184,300 184,300/245,700 2 2 2 WCH240E WCH240E WCH240E AYHHTRN436A AYHHTRN454A AYHHTRN472A 460/3/60 460/3/60 460/3/60 36.0 54.0 72.0 122,900 184,300 245,700 2 2 2 WCH240E WCH240E WCH240E AYHHTRMW18A AYHHTRMW36A AYHHTRMW54A 575/3/60 575/3/60 575/3/60 18.0 36.0 54.0 61,400 122,900 184,300 1 2 2 WCH150E-WCH180E WCH150E-WCH180E WCH150E-WCH180E AYHHTRNW36A AYHHTRNW54A AYHHTRNW72A 575/3/60 575/3/60 575/3/60 36.0 54.0 72.0 122,900 184,300 245,700 2 2 2 WCH240E WCH240E WCH240E Note: Unit with heater is single circuit/single point. See ReliaTel™ and Micro Control features on PC-16 and PC-17. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PH-20 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 2-5 Tons Table PG-1-A — 4YCZ6 - Platinum ZM (Previously Triumph® 16) Convertible Packaged Gas/Electric - R-410A Model Number 4YCZ6 Platinum ZM CoolingHeating Capacity Capacity (BTUH) Output (1 Stg./2 Stg.) SEER Cabinet EER Shipping Max Sound Dim. (in.) High/Low AFUE(%)Weight MCA Fuse Rating H x D x W 4YCZ6 – 208-230/1/60 4YCZ6036A1075B 35,600 45,000/60,000 16.60 12.00/13.60 79.5 488 26.0 40 70 38 x 43 x 51 4YCZ6036A1096B 35,600 57,600/77,000 16.60 12.00/13.60 80.0 488 26.0 40 70 38 x 43 x 51 4YCZ6048A1096B 48,000 57,600/77,000 16.00 12.00/13.48 80.0 659 34.1 50 71 42 x 46 x 61 4YCZ6048A1120B 48,000 72,000/96,000 16.00 12.00/13.48 80.0 665 34.1 50 71 42 x 46 x 61 4YCZ6060A1120B 57,500 72,000/96,000 15.10 11.40/12.64 80.0 676 44.4 60 73 42 x 46 x 61 4YCZ6 – 208-230/3/60 4YCZ6036A3075B 35,600 45,000/60,000 16.60 12.00/13.60 80.0 488 19.1 30 70 36 x 43 x 51 4YCZ6036A3096B 35,600 57,600/77,000 16.60 12.00/13.60 80.0 493 19.1 30 70 36 x 43 x 51 4YCZ6048A3096B 48,000 57,600/77,000 16.00 12.00/13.48 80.0 659 25.2 35 71 42 x 46 x 61 4YCZ6048A3120B 48,000 72,000/96,000 16.00 12.00/13.48 80.0 665 25.2 35 71 42 x 46 x 61 4YCZ6060A3120B 57,500 72,000/96,000 15.10 11.40/12.65 80.0 676 28.6 40 73 42 x 46 x 61 4YCZ6 – 460/3/60 4YCZ6036A4075C 35,600 45,000/60,000 16.60 12.00/13.60 79.0 488 10.4 15 70 36 x 43 x 51 4YCZ6036A4096C 35,600 57,600/77,000 16.60 12.00/13.60 80.0 493 10.4 15 70 36 x 43 x 51 4YCZ6048A4096C 48,000 57,600/77,000 16.00 12.00/13.48 80.0 659 15.3 20 71 42 x 46 x 61 4YCZ6048A4120C 48,000 72,000/96,000 16.00 12.00/13.48 80.0 665 15.3 20 71 42 x 46 x 61 4YCZ6060A4120C 57,500 72,000/96,000 15.10 11.40/12.65 80.0 676 17.2 20 73 42 x 46 x 61 Table PG-1-B — 4YCY4 - Gold XM (Previously Triumph® 14) Convertible Packaged Gas/Electric - R-410A Model Number 4YCY4 Gold XM CoolingHeating Cabinet Capacity Capacity Shipping Max Sound Dimensions (in.) (BTUH) Output (1 Stg./2 Stg.) SEER/EER AFUE(%) WeightMCA Fuse Rating H x D xW 4YCY4 – 208-230/1/60 4YCY4024A1064A 23,400 38,400/51,000 14.00/12.00 79.0 481 16.5 25 68 36 x 43 x 51 4YCY4030A1075A 30,000 45,000/60,000 14.00/12.00 79.5 481 19.2 30 71 36 x 43 x 51 4YCY4036B1075A 38,000 45,000/60,000 14.20/12.00 79.5 488 24.6 40 69 36 x 43 x 51 4YCY4036B1096A 38,000 57,600/77,000 14.20/12.00 80.0 488 24.6 40 69 36 x 43 x 51 4YCY4042B1096B 42,000 57,600/77,000 14.25/12.00 80.0 653 31.5 50 74 38 x 46 x 61 4YCY4048B1096A 48,500 57,600/77,000 14.20/12.00 80.0 669 35.4 50 73 38 x 46 x 61 4YCY4048B1120A 48,500 72,000/96,000 14.20/12.00 80.0 675 35.4 50 73 38 x 46 x 61 4YCY4060A1120A 58,500 72,000/96,000 14.00/12.00 80.0 676 43.3 60 76 42 x 46 x 61 4YCY4 – 208-230/3/60 4YCY4036A3075A 36,000 45,000/60,000 14.20/11.60 80.0 488 19.8 30 69 36 x 43 x 51 4YCY4036A3096A 36,000 57,600/77,000 14.20/11.60 80.0 493 19.8 30 69 36 x 43 x 51 4YCY4048A3096A 48,000 57,600/77,000 14.20/11.90 80.0 653 26.4 40 73 38 x 46 x 61 4YCY4048A3120A 48,000 72,000/96,000 14.20/11.90 80.0 659 26.4 40 73 38 x 46 x 61 4YCY4060A3120A 58,500 72,000/96,000 14.00/12.00 80.0 676 30.6 45 76 42 x 46 x 61 For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-1 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 2-5 Tons Table PG-2-A — Features • • • • • • • • • • • • • • • • • • • • • • • • • • • • 4YCZ64YCY4 3-5 2-5 SEER up to............................................................................................................................................................... 16.60 14.25 Exclusive Duration™ high efficiency compressor with internal overload protection............................................... ✔ ✔ Factory supplied charge............................................................................................................................................ R-410A R-410A ✔ ✔ Composite Vortica® indoor blower............................................................................................................................ High efficiency ECM indoor blower motor with Comfort-R™ airflow system........................................................... ✔ ✔ All aluminum Spine Fin™ outdoor coil..................................................................................................................... ✔ ✔ Swept-blade outdoor fan for quiet operation............................................................................................................. ✔ ✔ Architecturally integrated louvers and corner guards............................................................................................... ✔ ✔ Cabinet constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint............................................................................................................................... ✔ ✔ Stainless steel heat exchanger and burners............................................................................................................. ✔ ✔ Single stage cool....................................................................................................................................................... — ✔ 2-stage cooling.......................................................................................................................................................... ✔— 2-stage gas............................................................................................................................................................... ✔ ✔ Start kit - factory installed (single phase only).......................................................................................................... — 2 & 2½ High pressure cutout................................................................................................................................................. ✔ ✔ Low pressure cutout.................................................................................................................................................. 3-Phase Only 3-Phase Only Liquid line drier - factory installed............................................................................................................................. ✔ ✔ Non-bleed expansion valves on indoor coil............................................................................................................... ✔ ✔ Pressure taps, including liquid line taps, easily accessed and protected inside compressor compartment............ ✔ ✔ Right side electrical service access for high and low voltage connections............................................................... ✔ ✔ Rugged steel basepan features deep drawn duct connections................................................................................ ✔ ✔ Steeply sloped composite drainpan.......................................................................................................................... ✔ ✔ Ships in horizontal configuration and converts quickly for downflow........................................................................ ✔ ✔ Copper tube, aluminum fin indoor coil...................................................................................................................... ✔ ✔ All models are certified to ANSI 221.47/CSA 2.3..................................................................................................... ✔ ✔ 20-year heat exchanger, 12-year compressor, 10-year outdoor coil, and 10-year all other functional parts registered limited warranty (Residential Use)1....................................... ✔— 20-year heat exchanger, 10-year compressor, 10-year outdoor coil, and 10-year all other functional parts registered limited warranty (Residential Use)1.......................................— ✔ Extended warranties available .............................................................................................................................. ✔ ✔ 1Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-2 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 2-5 Tons 4YCZ64YCY4 Table PG-3-A — Accessories 3-5 2-5 Model Number Description Shipping Weight BAYACCDOR1A.............Hinged Filter Access Doorw......................................................................................................................................... 3 2-3 BAYACCDOR2A.............Hinged Filter Access Doorw......................................................................................................................................... 3½-5 3½-5 BAYADAP050A...............Adapter Curb (Cabinet A/B).......................................................................................................................................... 3 2-3 BAYADAP051A...............Adapter Curb (Cabinet C)............................................................................................................................................. 3 2-3 BAYADAP052A...............Adapter Curb (Cabinet A/B).......................................................................................................................................... 4-5 3½-5 BAYADAP053A...............Adapter Curb (Cabinet C)............................................................................................................................................. 4-5 3½-5 BAYADAP054A...............Adapter Curb (Cabinet D)............................................................................................................................................. 4-5 3½-55 BAYASCT001.................Anti-Short Cycle Timer4.............................................................................................................................................. ✔ ✔ BAYCCHT101A..............Crankcase Heater (230v) (Reciprocation).................................................................................................................... — 2 BAYCCHT102A..............Crankcase Heater (230v) (Scroll)................................................................................................................................. 3,4,5 3,4,5 BAYCCHT404B..............Crankcase Heater (460v) (Scroll) ................................................................................................................................ 3,4,5 3,4,5 BAYCOVR112A..............12" Duct Shroud (Covers Horizontal Ducts)6.............................................................................................................. 3-5 2-5 BAYCOVR118A..............18" Duct Shroud (Covers Horizontal Ducts)6.............................................................................................................. 3-5 2-5 BAYCURB050A..............Flat Roof Full Perimeter Curb (Insulated)......................................................... 74........................................................3 2-3 BAYCURB051A..............Flat Roof Full Perimeter Curb (Insulated)......................................................... 74........................................................4-5 3½-5 BAYDMPR101A.............Motorized Fresh Air Damper17890....................................................................................................................... 3 2-3 BAYDMPR102A.............Motorized Fresh Air Damper17890....................................................................................................................... 4-5 3½-5 BAYECON101A..............Economizer with Barometric Relief (Downflow)1230q.............................. 50........................................................— 2-3 BAYECON102A..............Economizer with Barometric Relief (Downflow)1230q.............................. 65........................................................— 3½-5 BAYECON103A..............Economizer with Barometric Relief (Downflow)1230q.......................................................................................... 3 — BAYECON104A..............Economizer with Barometric Relief (Downflow)1230q.......................................................................................... 4-5 — BAYECON200A..............Economizer (Horizontal)1237..................................................................... 85........................................................— 2-3 BAYECON201A .............Economizer (Horizontal)1237..................................................................... 85........................................................— 3½-5 BAYECON203A..............Economizer (Horizontal)1237................................................................................................................................. 3 — BAYECON204A..............Economizer (Horizontal)1237................................................................................................................................. 4-5 — BAYECONCOMB101B......BAYECON101A, door, and filter kit.................................................................................................................................... — 2-3 BAYECONCOMB102B...BAYECON102A, door, and filter kit .............................................................................................................................. — 3½-5 BAYECONCOMB103B...BAYECON103A, door, and filter kit............................................................................................................................... 3 — BAYECONCOMB104B...BAYECON104A, door, and filter kit............................................................................................................................... 4-5 — BAYENTH001A..............Enthalpy Control Kit2 ....................................................................................... 2......................................................... ✔ ✔ BAYEXMK001A..............Extreme Conditions Mounting Kit (Used on BAYCURB & BAYADAP)......................................................................... ✔ ✔ BAYEXMK002B..............Extreme Conditions Mounting Kit (Used on BAYUTIL)................................................................................................. ✔ ✔ BAYEXMK003A..............Extreme Conditions Mounting Kit (Used on Slab Mounts)........................................................................................... ✔ ✔ BAYFLTR101C...............1-2" Filter Frame1-Requires one 20x25 filter (not included)............................... 6.........................................................3 2-3 BAYFLTR201C...............1-2" Filter Frame1-Requires one 20x20, and one 20x18 filters (not included)..................................................................................................... 6.........................................................4-5 3½-5 BAYLIFT002B.................Lifting Lug Kit .................................................................................................... 5......................................................... ✔ ✔ BAYLOAM105A..............Low Ambient Control Kit ................................................................................... 5......................................................... ✔ ✔ BAYLPKT100A.............. LP Conversion Kit..................................................................................................................................................... 40K,120K 40K,120K BAYLPKT101A.............. LP Conversion Kit..................................................................................................................................................... 64K,96K 64K, 96K BAYLPKT102A.............. LP Conversion Kit..................................................................................................................................................... 75K 75K BAYOSAC001B..............Outside Air Control for V.S. Economizere.................................................................................................................... 3,4,5 — BAYOSAH001A..............Manual Fresh Air Damper1 ............................................................................. 6.........................................................3 2-3 BAYOSAH002A..............Manual Fresh Air Damper1 ............................................................................. 8.........................................................4-5 3½-5 BAYQSTK301A..............Start Kit......................................................................................................................................................................... — ✔ BAYSQRD001A..............16" Round Duct Adapter5................................................................................ 5.........................................................3 2-3 BAYSQRD002A..............18" Round Duct Adapter5................................................................................ 3.........................................................4-5 2-5 BAYUTIL101B................Roof Curb Utility Extension Kit...................................................................................................................................... 3 2-3 BAYUTIL102B................Roof Curb Utility Extension Kit...................................................................................................................................... 4-5 3½-5 BAYUV101A................ 21" Retrofit UVC Lamp Kit......................................................................... 5..................................................... 1½-3 1½-3 BAYUV102A................ 33" Retrofit UVC Lamp Kit......................................................................... 5..................................................... 3½-5 3½-5 1Must use filter frame when economizer/fresh air kit is used. 2Dry bulb control standard with economizer. EXISTING NEW UNIT USE 32-Stage cooling control required when using economizer. CURB 2/4TC/WC/YC****A BAYADAP0**A 4Do not use with electronic thermostats. BAYCURB030,38A 018-036 50 5 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. BAYCURB030,38A 042-060 52 6 BAYCOVR112,118A will not cover BAYSQRD002A applications. BAYCURB033A 018-036 51 7Does not contain barometric relief. BAYCURB033A 042-060 53 8Max fresh air - 25%. BAYCURB034A 042-060 54 9For non-continuous fan gas-heating applications, the damper opens only when the OD ambient is above 50° F. 0It is the designer/engineer's responsibility to review product specifications prior to equipment selection to insure optimal performance and compliance to codes. qTemperature of mixed air entering the heat exchanger is monitored and fresh air intake may be reduced under certain conditions. wBAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward compatible to BAYFLTR101/201A. eBAYOSAC001B is not compatible with BAYACCDOR1A or BAYACCDOR2A For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-3 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 1½-5 Tons Table PG-4-A — 4YCX3 - Silver SI+ (Previously Triumph® 13) Convertible Packaged Gas/Electric - R-410A Model Number 4YCX3 Silver SI+ CoolingHeating Cabinet Capacity Capacity Shipping Max Sound Dimensions (in.) (BTUH) Input/Output SEER/EER AFUE(%)Weight MCA Fuse Rating H x D xW 4YCX3 – 208-230/1/60 4YCX3018A1040A 18,000 40,000/31,000 13.00/11.00 79.8 471 10.1 15 69 36 x 43 x 51 4YCX3024B1064A 24,000 64,000/51,000 13.00/11.00 79.0 499 13.6 20 70 36 x 43 x 51 4YCX3030B1075A 28,600 75,000/60,000 13.00/11.00 79.5 481 17.1 25 74 36 x 43 x 51 4YCX3036A1064B 36,000 64,000/51,000 13.00/11.00 80.0 488 25.2 40 71 36 x 43 x 51 4YCX3036A1075B 36,000 75,000/60,000 13.00/11.00 80.0 488 25.2 40 71 36 x 43 x 51 4YCX3036A1096B 36,000 96,000/76,000 13.00/11.00 80.0 493 25.2 40 71 36 x 43 x 51 4YCX3042B1096A 41,500 96,000/77,000 13.00/11.00 80.0 653 26.3 40 74 38 x 46 x 61 4YCX3048A1075A 46,500 75,000/61,000 13.00/11.00 80.0 645 31.5 50 73 38 x 46 x 61 4YCX3048A1096A 46,500 96,000/77,000 13.00/11.00 80.0 653 31.5 50 73 38 x 46 x 61 4YCX3048A1120A 46,500 120,000/95,00013.00/11.00 80.0 659 31.5 50 73 38 x 46 x 61 4YCX3060A1096A 60,000 96,000/77,000 13.00/10.95 80.0 678 43.3 60 75 40 x 46 x 61 4YCX3060A1120B 60,000 120,000/95,00013.00/10.95 80.0 684 41.9 60 75 40 x 46 x 61 4YCX3 – 208-230/3/60 4YCX3036A3064B 36,000 64,000/51,000 13.00/11.00 80.0 493 17.2 25 71 36 x 43 x 51 4YCX3036A3075B 36,000 75,000/60,000 13.00/11.00 80.0 488 17.2 25 71 36 x 43 x 51 4YCX3036A3096B 36,000 96,000/76,000 13.00/11.00 80.0 493 17.2 25 71 36 x 43 x 51 4YCX3048A3075A 46,500 75,000/61,000 13.00/11.00 80.0 645 24.0 35 73 38 x 46 x 61 4YCX3048A3096A 46,500 96,000/77,000 13.00/11.00 80.0 653 24.0 35 73 38 x 46 x 61 4YCX3048A3120A 46,500 120,000/95,00013.00/11.00 80.0 659 24.0 35 73 38 x 46 x 61 4YCX3060A3096B 60,000 96,000/77,000 13.00/10.95 80.0 678 31.7 50 75 40 x 46 x 61 4YCX3060A3120A 60,000 120,000/95,00013.00/10.95 80.0 684 28.6 40 75 40 x 46 x 61 4YCX3 – 460/3/60 4YCX3036A4064B 36,000 64,000/51,000 13.00/11.00 80.0 448 9.5 15 71 36 x 43 x 51 4YCX3036A4075B 36,000 75,000/60,000 13.00/11.00 80.0 448 9.5 15 71 36 x 43 x 51 4YCX3036A4096B 36,000 96,000/76,000 13.00/11.00 80.0 493 9.5 15 71 36 x 43 x 51 4YCX3048A4075A 46,500 75,000/61,000 13.00/11.00 80.0 645 11.7 15 73 38 x 46 x 61 4YCX3048A4096A 46,500 96,000/77,000 13.00/11.00 80.0 653 11.7 15 73 38 x 46 x 61 4YCX3048A4120A 46,500 120,000/95,00013.00/11.00 80.0 659 11.7 15 73 38 x 46 x 61 4YCX3060A4096A 60,000 96,000/77,000 13.00/10.95 80.0 678 19.5 25 75 40 x 46 x 61 4YCX3060A4120A 60,000 120,000/95,00013.00/10.95 80.0 684 19.5 25 75 40 x 46 x 61 For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-4 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 1½-5 Tons Table PG-5-A — 4YCC3 Silver SI (Previously American Standard 13) Convertible Packaged Gas/Electric - R-410A Model Number 4YCC3 Silver SI CoolingHeating Cabinet Capacity Capacity Shipping Max Sound Dimensions (in.) (BTUH) Input/Output SEER/EER AFUE(%)Weight MCA Fuse Rating H x D xW 4YCC3 – 208-230/1/60 4YCC3018A1040A 18,000 40,000/31,000 13.00/11.00 79.8 471 10.1 15 74 36 x 43 x 51 4YCC3024B1064A 23,000 64,000/51,000 13.00/11.00 79.0 385 13.6 20 76 36 x 43 x 51 4YCC3030B1075A 28,000 75,000/60,000 13.00/11.00 79.5 481 17.1 25 74 36 x 43 x 51 4YCC3036A1064B 35,000 64,000/51,000 13.00/11.00 80.0 488 25.2 40 75 36 x 43 x 51 4YCC3036A1075B 35,000 75,000/60,000 13.00/11.00 80.0 488 25.2 40 75 36 x 43 x 51 4YCC3036A1096B 35,000 96,000/76,000 13.00/11.00 80.0 493 25.2 40 75 36 x 43 x 51 4YCC3042B1096A 40,000 96,000/77,000 13.00/11.00 80.0 653 26.3 40 74 38 x 46 x 61 4YCC3048A1075A 46,500 75,000/61,000 13.00/11.00 80.0 645 31.5 50 80 38 x 46 x 61 4YCC3048A1096A 46,500 96,000/77,000 13.00/11.00 80.0 653 31.5 50 80 38 x 46 x 61 4YCC3048A1120A 46,500 120,000/95,00013.00/11.00 80.0 659 31.5 50 80 38 x 46 x 61 4YCC3060A1096A 58,000 96,000/77,000 13.00/10.95 80.0 678 43.5 60 79 40 x 46 x 61 4YCC3060A1120B 58,000 120,000/95,00013.00/10.95 80.0 684 41.9 60 79 40 x 46 x 61 4YCC3 – 208-230/3/60 4YCC3036A3064B 35,000 64,000/51,000 13.00/11.00 80.0 488 17.2 25 75 36 x 43 x 51 4YCC3036A3075B 35,000 75,000/60,000 13.00/11.00 80.0 488 17.2 25 75 36 x 43 x 51 4YCC3036A3096B 35,000 96,000/76,000 13.00/11.00 80.0 493 17.2 25 75 36 x 43 x 51 4YCC3048A3075A 46,500 75,000/61,000 13.00/11.00 80.0 645 24.0 35 80 38 x 46 x 61 4YCC3048A3096A 46,500 96,000/77,000 13.00/11.00 80.0 653 24.0 35 80 38 x 46 x 61 4YCC3048A3120A 46,500 120,000/95,00013.00/11.00 80.0 659 24.0 35 80 38 x 46 x 61 4YCC3060A3096A 58,000 96,000/77,000 13.00/10.95 80.0 678 31.5 50 79 40 x 46 x 61 4YCC3060A3120B 58,000 120,000/95,00013.00/10.95 80.0 684 28.6 40 79 40 x 46 x 61 4YCC3 – 460/3/60 4YCC3036A4064B 35,000 64,000/51,000 13.00/11.00 80.0 488 9.5 15 75 36 x 43 x 51 4YCC3036A4075B 35,000 75,000/60,000 13.00/11.00 80.0 488 9.5 15 75 36 x 43 x 51 4YCC3036A4096B 35,000 96,000/76,000 13.00/11.00 80.0 493 9.5 15 75 36 x 43 x 51 4YCC3048A4075A 46,500 75,000/61,000 13.00/11.00 80.0 645 11.7 15 80 38 x 46 x 61 4YCC3048A4096A 46,500 96,000/77,000 13.00/11.00 80.0 653 11.7 15 80 38 x 46 x 61 4YCC3048A4120A 46,500 120,000/95,00013.00/11.00 80.0 659 11.7 15 80 38 x 46 x 61 4YCC3060A4096A 58,000 96,000/77,000 13.00/10.95 80.0 678 19.3 25 79 40 x 46 x 61 4YCC3060A4120A 58,000 120,000/95,00013.00/10.95 80.0 684 19.3 25 79 40 x 46 x 61 For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-5 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 1½-5 Tons Table PG-6-A — Features • • • • • • • • • • • • • • • • • • • • • • • • • • • • 4YCX3 1½-5 4YCC3 1½-5 SEER up to .................................................................................................................................................. 13.00 13.00 Exclusive Duration™ high efficiency compressor with internal overload protection......................................... ✔— Factory supplied charge...................................................................................................................................... R-410A R-410A ✔ ✔ Composite Vortica® indoor blower...................................................................................................................... Direct drive multi-speed indoor blower motors.................................................................................................... ✔ ✔ All aluminum Spine Fin™ outdoor coil............................................................................................................... ✔ ✔ Swept-blade outdoor fan for quiet operation....................................................................................................... ✔ — Architecturally integrated louvers and corner guards......................................................................................... ✔ — All steel louvers .................................................................................................................................................. — ✔ Cabinet constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint......................................................................................................................... ✔ ✔ Stainless steel heat exchanger and burners....................................................................................................... ✔ ✔ Single stage cool................................................................................................................................................. ✔ ✔ Single stage gas.................................................................................................................................................. ✔ ✔ Start kit - factory installed (single phase only).................................................................................................... 1½ - 2½ 1½ - 2½ High pressure cutout........................................................................................................................................... ✔ ✔ Low pressure cutout............................................................................................................................................ 3 Phase Only 3 Phase Only Liquid line drier - factory installed....................................................................................................................... ✔ ✔ Non-bleed expansion valves on indoor coil......................................................................................................... ✔ ✔ Pressure taps, including liquid line taps, easily accessed and protected inside compressor compartment......................................................................................................................... ✔ ✔ Right side electrical service access for high and low voltage connections......................................................... ✔ ✔ Rugged steel basepan features deep drawn duct connections.......................................................................... ✔ ✔ Steeply sloped composite drainpan.................................................................................................................... ✔ ✔ Ships in horizontal configuration and converts quickly for downflow.................................................................. ✔ ✔ Copper tube, aluminum fin indoor coil................................................................................................................ ✔ ✔ All models are certified to ANSI 221.47/CSA 2.3............................................................................................... ✔ ✔ 20-year heat exchanger, 10-year compressor, 10-year outdoor coil, and 10-year all other functional parts registered limited warranty (Residential Use)1............................................... ✔ — 10-year heat exchanger, 10-year compressor, 10-year outdoor coil, and 10-year all other functional parts registered limited warranty (Residential Use)1...............................................— ✔ Extended warranties available ........................................................................................................................ ✔ ✔ 1Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-6 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 1½-5 Tons 4YCX34YCC3 1½-5 1½-5 Table PG-7-A — Accessories Model Number Description Shipping Weight BAYACCDOR1A.............. Hinged Filter Access Doorw ............................................................................................................... 1½-3 1½-3 BAYACCDOR2A.............. Hinged Filter Access Doorw................................................................................................................ 3½-5 3½-5 BAYADAP050A................ Adapter Curb (Cabinet A/B).................................................................................................................. 1½-3 1½-3 BAYADAP051A................ Adapter Curb (Cabinet C)..................................................................................................................... 1½-3 1½-3 BAYADAP052A................ Adapter Curb (Cabinet A/B).................................................................................................................. 3½-5 3½-5 BAYADAP053A................ Adapter Curb (Cabinet C)..................................................................................................................... 3½-5 3½-5 BAYADAP054A................ Adapter Curb (Cabinet D)..................................................................................................................... 3½-5 3½-5 BAYASCT001.................. Anti-Short Cycle Timer4...................................................................................................................... ✔ ✔ BAYCCHT101A............... Crankcase Heater (230v) (Reciprocation)............................................................................................ 1½-2 1½-2 BAYCCHT102A............... Crankcase Heater (230v) (Scroll)......................................................................................................... 3,4,5 3,4,5 BAYCCHT404B............... Crankcase Heater (460v) (Scroll) ........................................................................................................ 3,4,5 3,4,5 BAYCOVR112A............... 12" Duct Shroud (Covers Horizontal Ducts)6...................................................................................... 1½-5 1½-5 BAYCOVR118A............... 18" Duct Shroud (Covers Horizontal Ducts)6...................................................................................... 1½-5 1½-5 BAYCURB050A............... Flat Roof Full Perimeter Curb (Insulated).................................................................. 74....................... 1½-3 1½-3 BAYCURB051A............... Flat Roof Full Perimeter Curb (Insulated).................................................................. 74....................... 3½-5 3½-5 BAYDMPR101A.............. Motorized Fresh Air Damper17890............................................................................................... 1½-3 1½-3 BAYDMPR102A.............. Motorized Fresh Air Damper17890............................................................................................... 3½-5 3½-5 BAYECON101A............... Economizer with Barometric Relief (Downflow)1230q....................................... 50....................... 1½-3 1½-3 BAYECON102A............... Economizer with Barometric Relief (Downflow)1230q....................................... 65....................... 3½-5 3½-5 BAYECON200A............... Economizer (Horizontal)1237 ............................................................................. 85....................... 1½-3 1½-3 BAYECON201A .............. Economizer (Horizontal)1237 ............................................................................ 85....................... 3½-5 3½-5 BAYECONCOMB101A.......BAYECON101A, door, and filter kit............................................................................................................ 1½-3 1½-3 BAYECONCOMB102A.... BAYECON102A, door, and filter kit ...................................................................................................... 3½-5 3½-5 BAYENTH001A............... Enthalpy Control Kit2 ................................................................................................ 2........................ ✔ ✔ BAYEXMK001A............... Extreme Conditions Mounting Kit (Used on BAYCURB & BAYADAP)................................................. ✔ ✔ BAYEXMK002B............... Extreme Conditions Mounting Kit (Used on BAYUTIL)......................................................................... ✔ ✔ BAYEXMK003A............... Extreme Conditions Mounting Kit (Used on Slab Mounts)................................................................... ✔ ✔ BAYFLTR101C................ 1-2" Filter Frame1-Requires one 20x25 filter (not included)........................................ 6........................ 1½-3 1½-3 BAYFLTR201C................ 1-2" Filter Frame1-Requires one 20x20, and one 20x18 filters (not included) ....... 6........................ 3½-5 3½-5 BAYLIFT002B.................. Lifting Lug Kit ............................................................................................................. 5........................ ✔ ✔ BAYLOAM105A............... Low Ambient Control Kit ............................................................................................ 5........................ ✔ ✔ BAYLPKT100A............... LP Conversion Kit.............................................................................................................................. 40K,120K40K,120K BAYLPKT101A............... LP Conversion Kit.............................................................................................................................. 64K, 96K 64K, 96K BAYLPKT102A............... LP Conversion Kit.............................................................................................................................. 75K 75K BAYOSAH001A............... Manual Fresh Air Damper1 ...................................................................................... 6........................ 1½-3 1½-3 BAYOSAH002A............... Manual Fresh Air Damper1 ...................................................................................... 8........................ 3½-5 3½-5 BAYQSTK301A............... Start Kit................................................................................................................................................. ✔ ✔ BAYSQRD001A............... 16" Round Duct Adapter5......................................................................................... 5........................ 1½-3 1½-3 BAYSQRD002A............... 18" Round Duct Adapter5......................................................................................... 3........................ 1½-5 1½-5 BAYUTIL101B................. Roof Curb Utility Extension Kit.............................................................................................................. 1½-3 1½-3 BAYUTIL102B................. Roof Curb Utility Extension Kit.............................................................................................................. 3½-5 3½-5 BAYUV101A.................... 21" Retrofit UVC Lamp Kit.......................................................................................... 5........................ 1½-3 1½-3 BAYUV102A.................... 33" Retrofit UVC Lamp Kit.......................................................................................... 5........................ 3½-5 3½-5 1Must use filter frame when economizer/fresh air kit is used. 2Dry bulb control standard with economizer. EXISTING NEW UNIT USE 32-Stage cooling control required when using economizer. CURB 4TC/WC/YC****A BAYADAP0**A 4Do not use with electronic thermostats. BAYCURB030,38A 018-036 50 5 It is the responsibility of the installing dealer to properly size BAYCURB030,38A 042-060 52 the ductwork for each specific application. 6 BAYCOVR112,118A will not cover BAYSQRD002A applications. BAYCURB033A 018-036 51 7Does not contain barometric relief. BAYCURB033A 042-060 53 8Max fresh air - 25%. BAYCURB034A 042-060 54 9For non-continuous fan gas-heating applications, the damper opens only when the OD ambient is above 50° F. 0It is the designer/engineer's responsibility to review product specifications prior to equipment selection to insure optimal performance and compliance to codes. qTemperature of mixed air entering the heat exchanger is monitored and fresh air intake may be reduced under certain conditions. wBAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward compatible to BAYFLTR101/201A. For dimensional/outline drawings, please refer to Product Data. For information on Roof Curbs, please refer to the Accessories/Information Tab. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-7 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 3-10 Tons Standard Features: Beveled Top Smoother Design Small compact cabinet Recessed access handles • American Standard Heating & Air Conditioning scroll compressors on all 3-10 ton units • Colored and numbered wiring • Phase Monitor, R-410A, 3 Phase Units • Provisions for through the Base Gas and Condensate Drain Connections • 2" throwaway filters provided on all units • Liquid Line Refrigerant Drier • Operating Charge of R-410A • IAQ Sloped Drain Pans • Low Ambient to 40°F on Electromechanical models • Low Ambient to 0°F on ReliaTel™ models • 5 - year Limited Compressor Warranty • 5 - year Limited Heat Exchanger Warranty • 1 - year Limited Parts Warranty Added Flexibility • Electromechanical or ReliaTel™ controls (See page PC-16 for ReliaTel™ Control Information) • Standard or high efficiency cooling models available. 17+ available in 3T to 5T. For reference to 17+ please refer to publications RT-PRC048-EN and RT-SLB020-EN. • Low, medium or high heat, single or two stage • Convertible airflow • Fork lift openings on three sides of unit • Direct or belt drive - standard or oversized motors • We don’t prepackage options • Choose options tailored to suit each job —pay only for what is needed • Units ship with options installed —and within our standard ship cycle time Factory Installed Options • Through-the-Base — Electrical • Convenience Outlet — Powered or unpowered • Unit Disconnect Switch • Circuit Breaker • Smoke Detectors — Supply, return, or both • Condenser Coil Coating • Hinged Access Service Panels • Discharge Air Sensor • Fan Fail and Clogged Filter Switches • Condenser Coil Guard — Hail Protection Quality • Hot Gas Reheat Coil - Dehumidification • Expansion valve and split face evaporator coil • Novar Controls • Comm 3/4 Communications Interface • 2" Pleated Media filters (MERV 8 & 13) • Frostat • Multi-Speed & Single Zone VAV ID Airflow The same American Standard Heating & Air Conditioning Quality and Reliability … with added Flexibility! For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-8 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 3-5 Tons, 15 SEER, R-410A Table PG-9-A — Base Unit — 15 SEER High Efficiency — Electromechanical or ReliaTel™ Heating Output1 Cabinet Unit Performance2 Cooling Capacity Dimensions (in.) Downflow Downflow Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return Shipping Weight Max. (Ibs.) MCA** Fuse** YHC - 208-230/1/60 - Single Phase - Low Heat 3 YHC036E1*LA0000 15.2 38,490 48,000 78 36 x 43 x 69 16 x 15.5 24 x 14 555 26.7 40 4 YHC048E1*LA0000 15.0 48,930 48,000 80 42 x 53 x 88 33 x 17.5 32.2 x 17.5 798 35.7 50 5 YHC060E1*LA0000 15.0 62,490 48,000 80 42 x 53 x 88 33 x 17.5 32.2 x 17.5 823 43.8 70 YHC - 208-230/3/60 - Three Phase - Low Heat 3 YHC036E3*LA0000 15.0 38,490 48,000 78 36 x 43 x 69 16 x 15.5 24 x 14 637 21.9 30 4 YHC048E3*LA0000 15.0 49,930 48,000 80 42 x 53 x 88 33 x 17.5 32.2 x 17.5 869 28.3 40 5 YHC060E3*LA0000 15.0 63,490 48,000 80 42 x 53 x 88 33 x 17.5 32.2 x 17.5 894 32.1 45 YHC - 460/3/60 - Three Phase - Low Heat 3 YHC036E4*LA0000 15.0 38,490 48,000 78 36 x 43 x 69 16 x 15.5 24 x 14 637 10.2 15 4 YHC048E4*LA0000 15.0 49,930 48,000 80 42 x 53 x 88 33 x 17.5 32.2 x 17.5 869 13.8 20 5 YHC060E4*LA0000 15.0 63,490 48,000 80 42 x 53 x 88 33 x 17.5 32.2 x 17.5 894 17.0 25 YHC - 208-230/1/60 - Single Phase - Medium Heat 3 YHC036E1*MA0000 15.2 38,490 65,000 78 36 x 43 x 69 16 x 15.5 24 x 14 637 26.7 40 4 YHC048E1*MA0000 15.0 48,930 64,000 79 42 x 53 x 88 33 x 17.5 32.2 x 17.5 869 35.7 50 5 YHC060E1*MA0000 15.0 62,490 64,000 79 42 x 53 x 88 33 x 17.5 32.2 x 17.5 894 43.8 70 YHC - 208-230/3/60 - Three Phase - Medium Heat 3 YHC036E3*MA0000 15.0 38,490 64,000 78 36 x 43 x 69 16 x 15.5 24 x 14 637 21.9 30 4 YHC048E3*MA0000 15.0 49,930 64,000 79 42 x 53 x 88 33 x 17.5 32.2 x 17.5 869 28.3 40 5 YHC060E3*MA0000 15.0 63,490 64,000 79 42 x 53 x 88 33 x 17.5 32.2 x 17.5 894 32.1 45 YHC - 460/3/60 - Three Phase - Medium Heat 3 YHC036E4*MA0000 15.0 38,490 64,000 78 36 x 43 x 69 16 x 15.5 24 x 14 637 10.2 4 YHC048E4*MA0000 15.0 49,930 64,000 79 42 x 53 x 88 33 x 17.5 32.2 x 17.5 869 13.8 5 YHC060E4*MA0000 15.0 63,490 64,000 79 42 x 53 x 88 33 x 17.5 32.2 x 17.5 894 17.0 15 20 25 YHC - 208-230/1/60 - Single Phase - High Heat 3 YHC036E1*HA0000 15.2 38,490 96,000 78 36 x 43 x 69 16 x 15.5 24 x 14 637 26.7 40 4 YHC048E1*HA0000 15.0 48,930 96,000 79 42 x 53 x 88 33 x 17.5 32.2 x 17.5 869 35.7 50 5 YHC060E1*HA0000 15.0 62,490 104,000 80 42 x 53 x 88 33 x 17.5 32.2 x 17.5 894 43.8 70 YHC - 208-230/3/60 - Three Phase - High Heat 3 YHC036E3*HA0000 15.0 38,490 96,000 78 36 x 43 x 69 16 x 15.5 24 x 14 637 21.9 30 4 YHC048E3*HA0000 15.0 49,930 96,000 79 42 x 53 x 88 33 x 17.5 32.2 x 17.5 869 28.3 40 5 YHC060E3*HA0000 15.0 63,490 104,000 80 42 x 53 x 88 33 x 17.5 32.2 x 17.5 894 32.1 45 YHC - 460/3/60 - Three Phase - High Heat 3 YHC036E4*HA0000 15.0 38,490 96,000 78 36 x 43 x 69 16 x 15.5 24 x 14 637 10.2 15 4 YHC048E4*HA0000 15.0 49,930 96,000 79 42 x 53 x 88 33 x 17.5 32.2 x 17.5 869 13.8 20 5 YHC060E4*HA0000 15.0 63,490 104,000 80 42 x 53 x 88 33 x 17.5 32.2 x 17.5 894 17.0 25 1 Downflow Airflow/Horizontal Airflow 2 SEER applies, 3-5 tons; EER applies 6-10 tons. * Digit 9-E=Electromechanical or R=ReliaTel™. ** Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-9 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 3-5 Tons, 13 SEER, R-410A Table PG-10-A — Base Unit — 13 SEER — Electromechanical or ReliaTel™ Heating Output1 Cabinet Unit Performance2 Cooling Capacity Dimensions (in.) Downflow Downflow Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return Shipping Weight Max. (Ibs.) MCA** Fuse** YSC –208-230/1/60 – Single Phase – Low Heat 3 YSC036E1*LA0000 13.0 35,620 48,000 80 36 x 43 x 69 18 x 15.5 12 x 14 607 27.2 40 4 YSC048E1*LA0000 13.0 49,210 48,000 80 36 x 43 x 69 18 x 15.5 12 x 14 638 35.2 50 5 YSC060E1*LA0000 13.0 59,900 48,000 80 36 x 43 x 69 18 x 15.5 12 x 14 688 43.8 70 YSC –208-230/3/60 – Three Phase – Low Heat 3 YSC036E3*LA0000 13.0 37,150 48,000 80 36 x 43 x 69 18 x 15.5 12 x 14 607 23.0 35 4 YSC048E3*LA0000 13.0 49,450 48,000 80 36 x 43 x 69 18 x 15.5 12 x 14 638 25.2 35 5 YSC060E3*LA0000 13.0 62,270 48,000 80 36 x 43 x 69 18 x 15.5 12 x 14 688 29.5 45 YSC –460/3/60 – Three Phase – Low Heat 3 YSC036E4*LA0000 13.0 37,150 48,000 80 36 x 43 x 69 18 x 15.5 12 x 14 607 11.7 15 4 YSC048E4*LA0000 13.0 49,450 48,000 80 36 x 43 x 69 18 x 15.5 12 x 14 638 12.5 15 5 YSC060E4*LA0000 13.0 62,270 48,000 80 36 x 43 x 69 18 x 15.5 12 x 14 688 15.5 25 YSC –575/3/60 – Three Phase – Low Heat 3 YSC036EW*LA0000 13.0 37,150 48,000 80 36 x 43 x 69 18 x 15.5 12 x 14 607 9.4 15 4 YSC048EW*LA0000 13.0 49,450 48,000 80 36 x 43 x 69 18 x 15.5 12 x 14 638 9.0 15 5 YSC060EW*LA0000 13.0 62,270 48,000 80 36 x 43 x 69 18 x 15.5 12 x 14 688 10.1 15 YSC –208-230/1/60 – Single Phase – Medium Heat 3 YSC036E1*MA0000 13.0 35,620 64,000 80 36 x 43 x 69 18 x 15.5 12 x 14 607 27.2 40 4 YSC048E1*MA0000 13.0 49,210 64,000 80 36 x 43 x 69 18 x 15.5 12 x 14 638 35.2 50 5 YSC060E1*MA0000 13.0 59,900 64,000 80 36 x 43 x 69 18 x 15.5 12 x 14 688 43.8 70 YSC –208-230/3/60 – Three Phase – Medium Heat 3 YSC036E3*MA0000 13.0 37,150 64,000 81 36 x 43 x 69 18 x 15.5 12 x 14 607 23.0 35 4 YSC048E3*MA0000 13.0 49,450 64,000 81 36 x 43 x 69 18 x 15.5 12 x 14 638 25.2 35 5 YSC060E3*MA0000 13.0 62,270 64,000 81 36 x 43 x 69 18 x 15.5 12 x 14 688 29.5 45 YSC –460/3/60 – Three Phase – Medium Heat 3 YSC036E4*MA0000 13.0 37,150 64,000 80 36 x 43 x 69 18 x 15.5 12 x 14 607 11.7 15 4 YSC048E4*MA0000 13.0 49,450 64,000 80 36 x 43 x 69 18 x 15.5 12 x 14 638 12.5 15 5 YSC060E4*MA0000 13.0 62,270 64,000 80 36 x 43 x 69 18 x 15.5 12 x 14 688 15.5 25 YSC –575/3/60 – Three Phase – Medium Heat 3 YSC036EW*MA0000 13.0 37,150 64,000 80 36 x 43 x 69 18 x 15.5 12 x 14 607 9.4 15 4 YSC048EW*MA0000 13.0 49,450 64,000 80 36 x 43 x 69 18 x 15.5 12 x 14 638 9.0 15 5 YSC060EW*MA0000 13.0 62,270 64,000 80 36 x 43 x 69 18 x 15.5 12 x 14 688 10.1 15 YSC –208-230/1/60 – Single Phase – High Heat 3 YSC036E1*HA0000 13.0 35,620 96,000 80 36 x 43 x 69 18 x 15.5 12 x 14 607 27.2 40 4 YSC048E1*HA0000 13.0 49,210 96,000 80 36 x 43 x 69 18 x 15.5 12 x 14 638 35.2 50 5 YSC060E1*HA0000 13.0 59,900 104,000 80 36 x 43 x 69 18 x 15.5 12 x 14 688 43.8 70 YSC –208-230/3/60 – Three Phase – High Heat 3 YSC036E3*HA0000 13.0 37,150 96,000 80 36 x 43 x 69 18 x 15.5 12 x 14 607 23.0 35 4 YSC048E3*HA0000 13.0 49,450 96,000 80 36 x 43 x 69 18 x 15.5 12 x 14 638 25.2 35 5 YSC060E3*HA0000 13.0 62,270 104,000 80 36 x 43 x 69 18 x 15.5 12 x 14 688 29.5 45 YSC –460/3/60 – Three Phase – High Heat 3 YSC036E4*HA0000 13.0 37,150 96,000 80 36 x 43 x 69 18 x 15.5 12 x 14 607 11.7 15 4 YSC048E4*HA0000 13.0 49,450 96,000 80 36 x 43 x 69 18 x 15.5 12 x 14 638 12.5 15 5 YSC060E4*HA0000 13.0 62,270 104,000 80 36 x 43 x 69 18 x 15.5 12 x 14 688 15.5 25 YSC –575/3/60 – Three Phase – High Heat 3 YSC036EW*HA0000 13.0 37,150 96,000 80 36 x 43 x 69 18 x 15.5 12 x 14 607 9.4 15 4 YSC048EW*HA0000 13.0 49,450 96,000 80 36 x 43 x 69 18 x 15.5 12 x 14 638 9.0 15 5 YSC060EW*HA0000 13.0 62,270 104,000 80 36 x 43 x 69 18 x 15.5 12 x 14 688 10.1 15 1 2 * ** Downflow Airflow/Horizontal Airflow SEER applies, 3-5 tons; EER applies 6-10 tons. Digit 9-E=Electromechanical or R=ReliaTel™. Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-10 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 6-10 Tons, R-410A Table PG-11-A — 17 Plus - R-410A - ReliaTel™ Controls Only Heating Output1 Cabinet Unit Performance2 Cooling Capacity Dimensions (in.) Downflow Downflow Tons Ordering No. EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return Shipping Weight Max. (Ibs.) MCA** Fuse** THC - 208-230/3/60 - Three Phase - Low Heat 3 YHC037E3RLA0000 17.5 36,500 48,000 78 36 x 44 x 69 18 x 15.5 24 x 14 676 23.3 30 4 YHC047E3RLA0000 17.5 50,500 49,000 80 41 x 53 x 88 33 x 17.5 33 x 17.5 858 29.4 40 5 YHC067E3RLA0000 17.2 60,000 49,000 80 41 x 53 x 88 33 x 17.5 33 x 17.5 917 32.2 45 THC - 460/3/60 - Three Phase - Low Heat 3 YHC037E4RLA0000 17.5 36,500 48,000 78 36 x 44 x 69 18 x 15.5 24 x 14 676 11.4 15 4 YHC047E4RLA0000 17.5 50,500 49,000 80 41 x 53 x 88 33 x 17.5 33 x 17.5 858 13.7 20 5 YHC067E4RLA0000 17.2 60,000 49,000 80 41 x 53 x 88 33 x 17.5 33 x 17.5 917 15.2 20 THC - 208-230/3/60 - Three Phase - Medium Heat 3 YHC037E3RMA0000 17.5 36,500 64,000 78 36 x 44 x 69 18 x 15.5 24 x 14 676 23.3 30 4 YHC047E3RMA0000 17.5 50,500 64,000 79 41 x 53 x 88 33 x 17.5 33 x 17.5 858 29.4 40 5 YHC067E3RMA0000 17.2 60,000 64,000 79 41 x 53 x 88 33 x 17.5 33 x 17.5 917 32.2 45 THC - 460/3/60 - Three Phase - Medium Heat 3 YHC037E4RMA0000 17.5 36,500 64,000 78 36 x 44 x 69 18 x 15.5 24 x 14 676 11.4 15 4 YHC047E4RMA0000 17.5 50,500 64,000 79 41 x 53 x 88 33 x 17.5 33 x 17.5 858 13.7 20 5 YHC067E4RMA0000 17.2 60,000 64,000 79 41 x 53 x 88 33 x 17.5 33 x 17.5 917 15.2 20 THC - 208-230/3/60 - Three Phase - High Heat 3 YHC037E3RHA0000 17.5 36,500 80,000 78 36 x 44 x 69 18 x 15.5 24 x 14 676 23.3 30 4 YHC047E3RHA0000 17.5 50,500 96,000 79 41 x 53 x 88 33 x 17.5 33 x 17.5 858 29.4 40 5 YHC067E3RHA0000 17.2 60,000 104,000 80 41 x 53 x 88 33 x 17.5 33 x 17.5 917 32.2 45 THC - 460/3/60 - Three Phase - High Heat 3 YHC037E4RHA0000 17.5 36,500 80,000 78 36 x 44 x 69 18 x 15.5 24 x 14 676 11.4 15 4 YHC047E4RHA0000 17.5 50,500 96,000 79 41 x 53 x 88 33 x 17.5 33 x 17.5 858 13.7 20 5 YHC067E4RHA0000 17.2 60,000 104,000 80 41 x 53 x 88 33 x 17.5 33 x 17.5 917 15.2 20 1 Downflow Airflow/Horizontal Airflow 2 SEER applies, 3-5 tons; EER applies 6-10 tons. * Digit 9-E=Electromechanical or R=ReliaTel™. ** Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-11 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 6-10 Tons, High Efficiency, R-410A Table PG-12-A — Base Unit — High Efficiency — Electromechanical or ReliaTel™ Heating Output1 Cabinet Unit Performance2 Cooling Capacity Dimensions (in.) Downflow Downflow Tons Ordering No. EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return Shipping Weight Max. (Ibs.) MCA** Fuse** YHC –208-230/3/60 – Three Phase – Low Heat 6 YHC072E3*LA0000 12.6 72,000 64,800 80 47 x 53 x 88 33 x 17.5 32.13 x 17.5 997 33.9 50 7½ YHC092F3*LA0000 12.6 92,000 96,000 80 47 x 53 x 88 33 x 17.5 32.13 x 17.5 1124 41.9 50 8½ YHC102E3*LA0000 13.0 103,000 96,000 80 51 x 63 x 100 32.25 x 19.25 32.25 x 16.75 1553 44.7 60 10 YHC120E3*LA0000 12.5 119,000 120,000* 80 51 x 63 x 100 32.25 x 19.25 32.25 x 16.75 1563 50.3 60 YHC –460/3/60 – Three Phase – Low Heat 6 YHC072E4*LA0000 12.6 72,000 64,800 80 47 x 53 x 88 33 x 17.5 32.13 x 17.5 997 16.3 25 7½ YHC092F4*LA0000 12.6 92,000 96,000 80 47 x 53 x 88 33 x 17.5 32.13 x 17.5 1124 19.9 25 8½ YHC102E4*LA0000 13.0 103,000 96,000 80 51 x 63 x 100 32.25 x 19.25 32.25 x 16.75 1553 22.9 30 10 YHC120E4*LA0000 12.5 119,000 120,000* 80 51 x 63 x 100 32.25 x 19.25 32.25 x 16.75 1563 24.9 30 YHC –208-230/3/60 – Three Phase – Medium Heat 6 YHC072E3*MA0000 12.6 72,000 96,000 80 47 x 53 x 88 33 x 17.5 32.13 x 17.5 997 33.9 50 7½ YHC092F3*MA0000 12.6 92,000 120,000* 80 47 x 53 x 88 33 x 17.5 32.13 x 17.5 1124 41.9 50 8½ YHC102E3*MA0000 13.0 103,000 120,000* 80 51 x 63 x 100 32.25 x 19.25 32.25 x 16.75 1553 44.7 60 10 YHC120E3*MA0000 12.5 119,000 160,000* 80 51 x 63 x 100 32.25 x 19.25 32.25 x 16.75 1563 50.3 60 YHC –460/3/60 – Three Phase – Medium Heat 6 YHC072E4*MA0000 12.6 72,000 96,000 80 47 x 53 x 88 33 x 17.5 32.13 x 17.5 997 16.3 25 7½ YHC092F4*MA0000 12.6 92,000 120,000* 80 47 x 53 x 88 33 x 17.5 32.13 x 17.5 1124 19.9 25 8½ YHC102E4*MA0000 13.0 103,000 120,000* 80 51 x 63 x 100 32.25 x 19.25 32.25 x 16.75 1553 22.9 30 10 YHC120E4*MA0000 12.5 119,000 160,000* 80 51 x 63 x 100 32.25 x 19.25 32.25 x 16.75 1563 24.9 30 YHC –208-230/3/60 – Three Phase – High Heat 6 YHC072E3*HA0000 12.6 72,000 120,000* 80 47 x 53 x 88 33 x 17.5 32.13 x 17.5 997 33.9 50 7½ YHC092F3*HA0000 12.6 92,000 160,000* 80 47 x 53 x 88 33 x 17.5 32.13 x 17.5 1124 41.9 50 8½ YHC102E3*HA0000 13.0 103,000 160,000* 80 51 x 63 x 100 32.25 x 19.25 32.25 x 16.75 1553 44.7 60 10 YHC120E3*HA0000 12.5 119,000 200,000* 80 51 x 63 x 100 32.25 x 19.25 32.25 x 16.75 1563 50.3 60 YHC –460/3/60 – Three Phase – High Heat 6 YHC072E4*HA0000 12.6 72,000 120,000* 80 47 x 53 x 88 33 x 17.5 32.13 x 17.5 997 16.3 25 7½ YHC092F4*HA0000 12.6 92,000 160,000* 80 47 x 53 x 88 33 x 17.5 32.13 x 17.5 1124 19.9 25 8½ YHC102E4*HA0000 13.0 103,000 160,000* 80 51 x 63 x 100 32.25 x 19.25 32.25 x 16.75 1553 22.9 30 10 YHC120E4*HA0000 12.5 119,000 200,000* 80 51 x 63 x 100 32.25 x 19.25 32.25 x 16.75 1563 24.9 30 1 Downflow Airflow/Horizontal Airflow 2 SEER applies, 3-5 tons; EER applies 6-10 tons. * Digit 9-E=Electromechanical or R=ReliaTel™. ** Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-12 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 6-10 Tons, R-410A Table PG-13-A — Base Unit — High Efficiency — Electromechanical or ReliaTel™ Heating Output1 Cabinet Unit Performance2 Cooling Capacity Dimensions (in.) Downflow Downflow Tons Ordering No. EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return Shipping Weight Max. (Ibs.) MCA** Fuse** YSC –208-230/3/60 – Three Phase – Low Heat 6 YSC072E3*LA0000 11.2 75,000 64,800 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 936 36.5 50 7½ YSC090E3*LA0000 11.2 89,000 120,000 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 916 38.2 60 7½ YSC092E3*LA0000 11.2 94,000 97,200 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1059 41.2 50 8½ YSC102E3*LA0000 11.2 102,000 97,200 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1096 46.3 60 10 YSC120F3*LA0000 11.3 118,000 121,500 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1156 49.6 60 YSC –460/3/60 – Three Phase – Low Heat 6 YSC072E4*LA0000 11.2 75,000 64,800 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 936 18.2 25 7½ YSC090E4*LA0000 11.2 89,000 120,000 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 916 19.5 30 7½ YSC092E4*LA0000 11.2 94,000 97,200 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1059 21.5 25 8½ YSC102E4*LA0000 11.2 102,000 97,200 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1096 21.9 25 10 YSC120F4*LA0000 11.3 118,000 121,500 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1156 22.7 35 YSC –575/3/60 – Three Phase – Low Heat 6 YSC072EW*LA0000 11.2 75,000 64,800 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 936 12.7 20 7½ YSC090EW*LA0000 11.2 89,000 120,000 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 916 14.7 20 7½ YSC092EW*LA0000 11.2 94,000 97,200 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1059 15.0 20 8½ YSC102EW*LA0000 11.2 102,000 97,200 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1096 17.5 20 10 YSC120FW*LA0000 11.3 118,000 121,500 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1156 18.9 25 YSC –208-230/3/60 – Three Phase – Medium Heat 6 YSC072E3*MA0000 11.2 75,000 97,200 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 936 36.5 50 7½ YSC090E3*MA0000 11.2 89,000 150,000 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 916 38.2 60 7½ YSC092E3*MA0000 11.2 94,000 121,500 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1059 41.2 50 8½ YSC102E3*MA0000 11.2 102,000 121,500 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1096 46.3 60 10 YSC120F3*MA0000 11.3 118,000 162,000 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1156 49.6 60 YSC –460/3/60 – Three Phase – Medium Heat 6 YSC072E4*MA0000 11.2 75,000 97,200 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 936 18.2 25 7½ YSC090E4*MA0000 11.2 89,000 150,000 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 916 19.5 30 7½ YSC092E4*MA0000 11.2 94,000 121,500 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1059 21.5 25 8½ YSC102E4*MA0000 11.2 102,000 121,500 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1096 21.9 25 10 YSC120F4*Ma0000 11.3 118,000 162,000 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1156 22.7 35 YSC –575/3/60 – Three Phase – Medium Heat 6 YSC072EW*MA0000 11.2 75,000 97,200 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 936 12.7 20 7½ YSC090EW*MA0000 11.2 89,000 150,000 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 916 14.7 20 7½ YSC092EW*MA0000 11.2 94,000 121,500 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1059 15.9 20 8½ YSC102EW*MA0000 11.2 102,000 121,500 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1096 17.5 20 10 YSC120FW*MA0000 11.3 118,000 162,000 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1156 18.9 25 YSC –208-230/3/60 – Three Phase – High Heat 6 YSC072E3*HA0000 11.2 75,000 121,500 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 936 36.5 50 7½ YSC090E3*HA0000 11.2 89,000 200,000 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 916 38.2 60 7½ YSC092E3*HA0000 11.2 94,000 162,000 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1059 41.2 50 8½ YSC102E3*HA0000 11.2 102,000 162,000 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1096 46.3 60 10 YSC120F3*HA0000 11.3 118,000 205,500 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1156 49.6 60 YSC –460/3/60 – Three Phase – High Heat 6 YSC072E4*HA0000 11.2 75,000 121,500 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 936 18.2 25 7½ YSC090E4*HA0000 11.2 89,000 200,000 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 916 19.5 30 7½ YSC092E4*HA0000 11.2 94,000 162,000 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1059 21.5 25 8½ YSC102E4*HA0000 11.2 102,000 162,000 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1096 21.9 25 10 YSC120F4*HA0000 11.3 118,000 205,500 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1156 22.7 35 YSC –575/3/60 – Three Phase – High Heat 6 YSC072EW*HA0000 11.2 75,000 121,500 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 936 12.7 20 7½ YSC090EW*HA0000 11.2 89,000 200,000 80 41 x 53 x 89 33 x 17.5 32.13 x 17.5 916 14.7 20 7½ YSC092EW*HA0000 11.2 94,000 162,000 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1059 15.9 20 8½ YSC102EW*HA0000 11.2 102,000 162,000 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1096 17.5 20 10 YSC120FW*HA0000 11.3 118,000 205,500 80 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1156 18.9 25 1 Downflow Airflow/Horizontal Airflow 2 SEER applies, 3-5 tons; EER applies 6-10 tons. * Digit 9-E=Electromechanical or R=ReliaTel™. ** Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-13 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 3-10 Tons (Model Digit Numbers) Digit Description Order Number 1-8 Main Assembly (see previous page) 9 Unit Controls Electromechanical .................................................. E ReliaTel™ Micro-processor......................................R 10 Heating Capacity Low.......................................................................... L Medium....................................................................M High.........................................................................H Low - Stainless Steel Heat Exchanger..................... X Medium - Stainless Steel Heat Exchanger.............. Y High - Stainless Steel Heat Exchanger.................... Z 11 Minor Design Sequence First Sequence....................................................... A 12-13 Service Sequence First Sequence (Factory assigned)........................ ✱,✱ 14 Fresh Air Selection No Fresh Air............................................................. 0 0-50% Manual Outside Air Damperw...................... A 0-50% Motorized Outside Air Damper..................... B 0-100% Economizer, Dry Bulb without Barometric Relief2...............................................C 0-100% Economizer, Dry Bulb with Barometric Relief2..............................................D 0-100% Economizer, Reference Enthalpy without Barometric Relief12................................ E 0-100%Economizer, Reference Enthalpy with Barometric Relief12 ................................... F 0-100%Economizer, Comparative Enthalpy without Barometric Relief 12...............................G 0-100%Economizer, Comparative Enthalpy with Barometric Relief 12....................................H 15 Supply Fan/Drive Type/Motor Standard Drive ........................................................ 0 Oversized Motor...................................................... 1 Optional Belt Drive Motoru...................................... 2 16 Hinged Service Access & Filters Standard Panels & Filters........................................ 0 Hinged Access Panels & Standard Filters............... A Standard panels & 2" Pleated Filters....................... B Hinged Access Panels & 2" Pleated Filters.............C Standard Panels & 2" MERV 13 Filters....................D Hinged Access Panels & 2" MERV 13 Filters.......... E 17 Condenser Coil Protection Standard Coil........................................................... 0 Standard Coil with Hail Guard................................. 1 Black Epoxy Pre-Coated Condenser Coil................ 2 Black Epoxy Pre-Coated Condenser Coil with Hail Guard..................................................... 3 Complete Coat™ Condenser Coil............................ 4 Complete Coat™ Condenser Coil with Hail Guard.. 5 1Enthalpy control not available factory installed with electro-mechanical controls. 2Economizer with Barometric Relief is for downfllow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must be ordered as field installed accessory BAYBARM010A. 3 Requires use of Disconnect or Circuit Breaker. 4 Standard refrigeration metering device - short orifice. 5Frostat cannot be field installed in electro-mechanical units. 6Not available with BAYFRST001A High Temperature Stat accessory. 7The return air smoke detector may not fit up or work properly on the Convertible units when used in conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not order the return air smoke detectors when using this type of accessory. 8Return Air Smoke Detector cannot be ordered with Novar Controls. 9These options are standard when ordering Novar Controls. 0This option is used when ordering Novar Controls. qIncludes gas piping and shutoff (field assembly required). wThe manual outside air damper will ship factory supplied within the unit, but must be field installed. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. Digit Description Order Number 18 Through the Base Provisions No Through the Base Provisions............................. 0 Through the Base Electricr .................................... A Through the Base Gas............................................. B Through the Base Gas and Electricq......................C 19 Disconnect/Circuit Breaker (3 phase only) No Disconnect Circuit Breaker................................. 0 Unit Mounted Non-Fused Disconnectr................... 1 Unit Mounted Circuit Breakerr................................ 2 20 Convenience Outlet No Convenience Outlet............................................ 0 Unpowered Convenience Outlet.............................. A Powered Convenience Outlet (3 phase only)3 ....... B 21 Communications Optionst No Communications Interface.................................. 0 Comm 3/4 Communications Interface...................... 1 Novar 2024 Controls................................................ 3 Novar 3051 Controls................................................ 4 22 Refrigeration System Option Standard Refrigeration System4 ............................ 0 Dehumidification (Hot Gas Reheat Coil)e............... B 23 Refrigeration Controls No Refrigeration Control ......................................... 0 Frostat5 .................................................................. 1 24 Smoke Detector6t No Smoke Detector................................................. 0 Return Air Smoke Detector78................................ A Supply Air Smoke Detector...................................... B Supply and Return Air Smoke Detectors78 ...........C 25 Monitoring Controlst No Monitoring Control9........................................... 0 Clogged Filter Switch9............................................ 1 Fan Failure Switch9................................................ 2 Discharge Air Sensing Tube9.................................. 3 Clogged Filter Switch and Fan Fail Switch9............ 4 Clogged Filter Switch and Discharge Air Sensing Tube9................................................ 5 Fan Fail Switch and Discharge Air Sensing Tube9 .6 Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tube9........................ 7 Novar Return Air Sensor0....................................... 8 Novar 3051 Zone Sensory...................................... 9 eRequires Selection of 2" Pleated Filters (Option B or C) for Digit 16. rThrough the base electric required when ordering disconnect/circuit breaker options. tNot available with electro-mechanical controls. yNovar Sensor utilized with Digit 21 = (4) Novar 3051 Controls without zone sensor. uDigit 15 Standard Efficiency 1 Phase = High Efficiency Multispeed Direct Drive Motor 3 Phase (3-8 ½ Ton) = Belt Drive 3 Phase (10 Ton) = Ultra High Efficiency Direct Drive Plenum Fan High Efficiency 1 Phase = High Efficiency Multispeed Direct Drive Motor 3 Phase (3-5 Ton) = High Efficiency Multispeed Direct Drive Motor 3 Phase (3-5 Ton w/Dehumidification) = Belt Drive Motor 3 Phase (7 ½ -10 Ton) = Ultra High Efficiency Direct Drive Plenum Fan PG-14 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 3-10 Tons Accessories Table PG-15-A — Accessories Model Number Description Used Withq BAYABRD001C3............ ReliaTel™ Options Module..............................All Y*C036-120E, R (ReliaTel™) See Note6 BAYASCT001C78......... Anti-Short-Cycle Timer.....................................All Y*C036-120E, E (Electro Mechanical) BAYBARM010A5........... Barometric Relief.............................................YSC036-060E, YHC036E BAYBARM011A5........... Barometric Relief ............................................YSC072E-102E, YSC120F, YHC048E-YHC092E,YHC092F YHC102E-120E BAYBCIR001A................. BACnet™ Communication Interface................ReliaTel™ Controller (BCI-R) BAYCCHT010B............... Crankcase Heater............................................YSC036-048E1, 3 BAYCCHT011B............... Crankcase Heater............................................YSC036-048E4, W BAYCCHT017A............... Crankcase Heater............................................YSC060E1,3 BAYCCHT018A............... Crankcase Heater............................................YSC060E4,W BAYCO2K001B39......... CO2 Sensor Kit, Wall Mounted.........................All Y*C036-120E,R (ReliaTel™) BAYCO2K003B39......... CO2 Sensor Kit, Duct Mounted........................All Y*C036-120E,R (ReliaTel™) BAYCURB042A2............ Roof Curb.........................................................YHC036E, YSC036-060E BAYCURB043A2............ Roof Curb.........................................................YHC048-072E, YSC072-120E, YHC092F BAYCURB044A............... Roof Curb.........................................................YHC102E-120E BAYDFPS003B36......... Clogged Filter Switch.......................................All Y*C036-120E, R (ReliaTel™) BAYDFPS014A................ Clogged Filter Switch (MERV 13 Filter)...........All Y*C036-120E, R (ReliaTel™) BAYDFPS004A36......... Fan Failure Switch............................................All Y*C036-120E, R (ReliaTel™) BAYDMPR053A0........... 0-50% Manual Outside Air Damper.................YHC036E, YSC036-060E BAYDMPR056B0........... 0-50% Manual Outside Air Damper.................YHC048-120E, YSC072-102E, YHC092F, YSC120F BAYDMPR051A3........... 0-50% Motorized Outside Air Damper.............YSC036-060E_R, YHC036E_R (ReliaTel™) BAYDMPR052A7........... 0-50% Motorized Outside Air Damper.............YHC036E_E, YSC036-060E_E, YHC037E_R (Electro Mechanical) BAYDMPR054A3........... 0-50% Motorized Outside Air Damper.............YHC048-120E_R, YSC072E-120E_R, YHC047E_R, YHC067E_R (ReliaTel™) BAYDMPR055A7........... 0-50% Motorized Outside Air Damper.............YHC048-120E_E, YSC072E-120E_E (Electro Mechanical) BAYECON085A3........... 0-100% Dry Bulb Economizer..........................YHC036E_R, YSC036-060E_R (ReliaTel™) BAYECON086A7........... 0-100% Dry Bulb Economizer .........................YHC036E_E, YSC036-060E_E (Electro Mechanical) without Barometric Relief BAYECON087A3........... 0-100% Dry Bulb Economizer .........................YHC048-120E_R, YSC072-120E_R (ReliaTel™) BAYECON088A7........... 0-100% Dry Bulb Economizer .........................YHC048-120E_E, YSC072-120E_E (Electro Mechanical) without Barometric Relief BAYENTH001A............... Enthalpy Control (Solid State)..........................BAYECON086A, 088A BAYENTH005A1 ........... Reference Enthalpy Kit....................................BAYECON085A, 087A BAYENTH006A1 ........... Comparative Enthalpy Kit.................................BAYECON085A, 087A BAYFRST003A34......... High Temperature Stat.....................................All Y*C036-120E BAYGARD037B............... Condenser Coil Hail Guard..............................YSC036-060E, YHC036E BAYGARD040A............... Condenser Coil Hail Guard..............................YHC048-060E,YSC072E-090E BAYGARD041A............... Condenser Coil Hail Guard..............................YSC092E, YSC102E, YHC072E BAYGARD070A............... Condenser Coil Hail Guard..............................YHC102E, YHC120E BAYGARD141A............... Condenser Coil Hail Guard..............................YSC120F, YHC092F BAYHAKT010C............... High Altitude Kit...............................................All Y*C036-120E 1 Kits contain all necessary parts to achieve desired level of enthalpy control. 2Lynn Haven Manufacturing has a No-Return policy for this roof curb. 3For use with ReliaTel™ controlled units only. 4Cannot be used in conjunction with factory installed Smoke Detector option. 5Installs in ductwork for horizontal configuration. For downflow configuration, it installs in the unit's horizontal return duct. See Installer's Guide for more information. 6BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A),Discharge Air Sensing Kit (BAYTUBE004A or BAYTUBE005A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) Ventilation Override Kit (BAYVNOR001B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options include the ReliaTel™ Options Module. 7Electromechanical controlled units only 8Activated on Power on. 9Field installed accessory. Requires an economizer. 0The manual outside air damper will ship factory supplied within the unit, but must be field installed. qA=R-22, E=410A For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-15 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 3-10 Tons Accessories Table PG-16-A — Accessories Model Number Description Used With9 BAYHSMT082A.................. 2 HP Oversized motor kit (208-230/460V)...................YSC072E3, 4 BAYHSMT083A.................. 2 HP Oversized motor kit (575V).................................YSC072EW BAYHSMT402A.................. 2 HP Oversized motor kit.............................................YHC072E3, 4 BAYHSMT086A.................. 3 HP Oversized motor kit (208-230/460V)...................YSC090-102E3, 4 BAYHSMT087A.................. 3 HP Oversized motor kit (575V).................................YSC090-102EW BAYLSDR009A................... Low Static Drive Kit......................................................YHC072E BAYHSDR012A.................. High Static Drive Kit.....................................................YSC072E BAYKSKT255B................... Quick Start Kit..............................................................YSC036-060E1 BAYLMSW001A0.............. Power Exhaust Limit Switch.........................................All Y*C036-120E BAYLOAM020B15........... Evaporator Defrost Control (Frostat) ...........................All Y*C036-120E, R (ReliaTel™) BAYLPKT029C................... LP Conversion Kit........................................................YSC072E,H, YSC090-102,M,H, YSC120,L,M,H YHC072E,H, YHC092-102E,M,H, YHC120E,L,M,H BAYLPKT050B................... LP Conversion Kit........................................................YSC036-060E,L,M,H, YSC072E,L,M, YSC090-102E,L YHC036-060E,L,M,H, YHC072E,L,M, YHC092-102E,L BAYPWRX070A................. Power Exhaust (208-230/3 VAC)..................................YSC036-060E3, YCH036-YHC060E3, YHC037E3, YHC047E3, YHC067E3 BAYPWRX071A................. Power Exhaust (460/3 VAC).........................................YSC036-060E4, YCH036-YHC060E4, YHC037E4, YHC047E4, YHC067E4 BAYPWRX072A................. Power Exhaust (575/3 VAC).........................................YSC036-060EW BAYPWRX026A................. Power Exhaust (208-230/3 VAC)..................................YSC072-102E3, YSC120F3, YHC072E3, YHC092F3, YHC102E3, YCH120E3 BAYPWRX027A................. Power Exhaust (460/3 VAC).........................................YSC072-102E4, YSC120F4, YHC072E4, YHC092F4, YHC102E4, YCH120E4 BAYPWRX028A................. Power Exhaust (575/3 VAC).........................................YSC072-102EW, YSC120FW BAYQACB009A.................. Quick Adapt Roof Curb................................................YSC036-060E, YHC036E, YHC037E BAYQACB010A.................. Quick Adapt Roof Curb................................................YSC036-060E, YHC036E, YHC037E BAYQACB011A.................. Quick Adapt Roof Curb................................................YSC072-102E, YSC120F, YHC048-072E, YHC047E, YHC067E BAYQACB012A.................. Quick Adapt Roof Curb................................................YSC072-102E, YSC120F, YHC048-072E, YHC047E, YHC067E BAYQACB013A.................. Quick Adapt Roof Curb................................................YSC072-102E, YSC120F, YHC048-072E, YHC047E, YHC067E BAYRTEM001Aq............... Fully Featured ReliaTel™ Economizer Logic Model....All Y*C036-120E BAYSENS016A4 .............. Temperature Sensor....................................................All Y*C036-120E BAYSERV001A4 .............. Selective Resistance Service Tester............................All Y*C036-120E BAYSTAT0234................... Remote Potentiometer.................................................All Y*C036-120E BAYTUBE004A425 ....... Discharge Air Sensing Kit............................................YSC036-060E, R, YHC036E, R BAYTUBE006A425 ....... Discharge Air Sensing Kit............................................YSC072-102E, R, YHC048-072E, R BAYTUBE400A................... Discharge Air Sensing Kit............................................YSC120E,R BAYTUBE402A................... Discharge Air Sensing Kit............................................YHC092-120E,R BAYVNOR001B485 ...... Ventilation Override Kit................................................All Y*C036-120E 1 For use with ReliaTel™ microprocessor controlled units only. Must be factory installed for Electromechanical controlled units. 2Used for true discharge air sensing in both heating and cooling. Required for supply air tempering. 3Lynn Haven Manufacturing has a No-Return policy for this roof curb. 4For use with ReliaTel™ controlled units only. 5BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A),Discharge Air Sensing Kit (BAYTUBE004A or BAYTUBE005A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) Ventilation Override Kit (BAYVNOR001B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options include the ReliaTel™ Options Module. 6BAYQACB009A adapts YCD units BAYCURB021B to accept Y*C 3 -5 ton unit. BAYQACB010A adapts YCD units BAYCURB022B to accept Y*C 3-5 ton unit. BAYQACB012A adapts YCD units BAYCURB025B to accept Y*C 3-5 ton unit. BAYQACB013A adapts YCD units BAYCURB026B to accept Y*C 6-10 ton unit. BAYQACB011A adapts YCD units BAYCURB022B to accept Y*C 6-10 ton unit. 7Power Exhaust cannot be used with Barometric Relief. Order Economizer without Barometric Relief. 8Field installed accessory. Requires an economizer. 9E=410A 0When ordering a field installed power exhaust on a unit with electromechanical controls, BAYLMSW001A must be ordered. q If any version of comparative or reference enthalpy is ordered, BAYRTEM001A does not need to be ordered. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-16 Effective 7/1/12 14-1011-28 Packaged Gas/Electric Convertible 3-10 Tons, R-410A Zone Sensors / Thermostats Table PG-17-A — Zone Sensors for ReliaTel™ Controlled Units Model Number Description Used With ASYSTAT106A ASYSTAT107A ASYSTAT108A ASYSTAT109A ASYSTAT111A ASYSTAT777A ASYSTAT708A ASYSTAT710A ASYSTAT711A BAYMTPL110A Y*C036-120E, R Y*C036-120E, R Y*C036-120E, R Y*C036-120E, R Y*C036*120E, R Y*C036-120E, R Y*C036-120E, R Y*C036-120E Y*C036-120E ASYSTAT666C Single Setpoint Manual Changeover Single Setpoint Dual Setpoint Manual or Auto Changeover Dual Setpoint Changeover Sensor Remote Room Sensor Programmable Night Setback w/System Function Lights (Vertical Style) Programmable Night Setback w/System Function Lights Wall Mounted Humidity Sensor Duct Mounted Humidity Sensor Retrofit Wall Cover Plate Kit 7.25" x 6.0" For additional Controls Information: See ReliaTel™ and Micro Control features on PC-16 and PC-17. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-17 Effective 7/1/12 14-1011-28 Packaged Gas/Electric with ReliaTel™ Controls 12½-25 Tons, R-410A 12½ - 25 Ton YCD-F — Downflow 12½ - 25 Ton YCH-F — Horizontal Table PG-18-A — R-410A • Scroll compressors on all units • ReliaTel™ control features are listed on page PC-16 • Operating charge of R-410A • Built-in anti-short cycle timer, time delay relay and minimum on time controls • Low Ambient to 0°F standard • High efficiency drum and tube heat exchanger • Color coded and numbered wiring • Two inch throwaway filters on both YCH and YCD to clean air and keep coil maintenance low • Simple U-shaped airflow pattern results in very low airside energy requirement Cooling Heating Output Unit Power Supply Performance Capacity Capacity Dimensions (in.) Tons Model No. Volts/Phase/Hz EER3 (Btuh) (Btuh) H x W x L • Quick-Access doors and single side access make servicing much faster for lower maintenance costs • Quick-adjust idler arm pulley. Adjust belt tension, change belts, adjust airflow quickly • High efficiency gas heat with hot surface ignition for low heating energy costs, low maintenance and high reliability • Sloped sheet metal drain pans • 5-year limited compressor and heat exchanger warranty (12½ -17½ tons) • 1-year limited compressor and heat exchanger warranty (20 tons) Shipping Max Fuse Size Weight or MaxDownflow1 (Ibs.) MCA** Circuit Breaker** Roofcurb YC* - Three Phase Low Heat 121/2 YC*151F300A 208-230/3/60 12.1 140,000 122,000 54 x 855/16 x 1225/162550 65 80 BAYCURB027B 15 YC*181F300A208-230/3/60 12.0 172,000 203,000641/8 x 855/16 x 1225/162500 72 90 BAYCURB027B 171/2 YC*211F300A208-230/3/60 11.8 198,000 203,000641/8 x 855/16 x 1225/162578 88 110 BAYCURB027B 20 YC*241F300A208-230/3/60 11.0 242,000 203,000641/8 x 855/16 x 1225/162581 104 125 BAYCURB027B 25 YC*301F300A208-230/3/60 10.6 272,0002203,000 641/8 x 855/16 x 1225/162544 116 150 BAYCURB027B 121/2 YC*151F400A 460/3/60 12.1 140,000 122,000 54 x 855/16 x 1225/162550 32 40 BAYCURB027B 15 YC*181F400A 460/3/60 12.0 172,000 203,000641/8 x 855/16 x 1225/162500 36 45 BAYCURB027B 171/2YC*211F400A 460/3/60 11.8 198,000 203,000641/8 x 855/16 x 1225/162578 42 50 BAYCURB027B 20 YC*241F400A 460/3/60 11.0 242,000 203,000641/8 x 855/16 x 1225/162581 50 60 BAYCURB027B 25 YC*301F400A 460/3/60 10.6272,0002203,000 641/8 x 855/16 x 1225/16 254456 70BAYCURB027B 121/2 YC*151FW00A 575/3/60 12.1 140,000 122,000 54 x 855/16 x 1225/162550 25 30 BAYCURB027B 15 YC*181FW00A 575/3/60 12.0 172,000 203,000641/8 x 855/16 x 1225/162500 29 40 BAYCURB027B 171/2YC*211FW00A 575/3/60 11.8 198,000 203,000641/8 x 855/16 x 1225/162578 36 45 BAYCURB027B 20 YC*241FW00A 575/3/60 11.0 242,000 203,000641/8 x 855/16 x 1225/162581 42 50 BAYCURB027B 25 YC*301FW00A575/3/60 10.6272,0002203,000 641/8 x 855/16 x 1225/16 254447 60BAYCURB027B YC* - Three Phase High Heat 121/2 YC*151F300A 208-230/3/60 12.1 140,000 203,000 54 x 855/16 x 1225/162550 65 80 BAYCURB027B 15 YC*181F300A208-230/3/60 12.0 172,000 284,000641/8 x 855/16 x 1225/162500 72 90 BAYCURB027B 171/2 YC*211F300A208-230/3/60 11.8 198,000 284,000641/8 x 855/16 x 1225/16 2578 88 110BAYCURB027B 20 YC*241F300A208-230/3/60 11.0 242,000 324,000 641/8 x 855/16x 1225/162581 104 125 BAYCURB027B 25 YC*301F300A208-230/3/60 10.6 272,000 324,000641/8 x 855/16 x 1225/16 2544116 150BAYCURB027B 121/2 YC*151F400A 460/3/60 12.1 140,000 203,000 54 x 855/16 x 1225/162550 32 40 BAYCURB027B 15 YC*181F400A 460/3/60 12.0 172,000 284,000641/8 x 855/16 x 1225/162500 36 45 BAYCURB027B 171/2YC*211F400A 460/3/60 11.8 198,000 284,000641/8 x 855/16 x 1225/162578 42 50 BAYCURB027B 20 YC*241F400A 460/3/60 11.0 242,000 324,000641/8 x 855/16 x 1225/16 258150 60BAYCURB027B 25 YC*301F400A 460/3/60 10.6 272,000 324,000641/8 x 855/16 x 1225/162544 56 70 BAYCURB027B 121/2 YC*151FW00A 575/3/60 12.1 140,000 203,000 54 x 855/16 x 1225/162550 25 30 BAYCURB027B 15 YC*181FW00A 575/3/60 12.0 172,000 284,000641/8 x 855/16 x 1225/162500 29 40 BAYCURB027B 171/2YC*211FW00A 575/3/60 11.8 198,000 284,000641/8 x 855/16 x 1225/162578 36 45 BAYCURB027B 20 YC*241FW00A 575/3/60 11.0 242,000 324,000641/8x 855/16 x 1225/16 258142 50BAYCURB027B 25 YC*301FW00A 575/3/60 10.6 272,000 324,000641/8x 855/16 x 1225/16 254447 60BAYCURB027B 1For Downflow units only. 2278,000 in the Horizontal airflow configuration. 3Downflow/Horizontal * Digit 3 D=Downflow or H=Horizontal. ** Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-18 Effective 7/1/12 14-1011-28 Packaged Gas/Electric with ReliaTel™ Controls 12½-25 Tons, R-410A 12½ - 25 Ton YCD-F — Downflow 12½ - 25 Ton YCH-F — Horizontal • Scroll compressors on all units • ReliaTel™ control features are listed on page PC-16 • Operating charge of R-410A • Built-in anti-short cycle timer, time delay relay and minimum on time controls • Low Ambient to 0°F standard • High efficiency drum and tube heat exchanger • Color coded and numbered wiring • Two inch throwaway filters on both YCH and YCD to clean air and keep coil maintenance low • Simple U-shaped airflow pattern results in very low airside energy requirement • Quick-Access doors and single side access make servicing much faster for lower maintenance costs • Quick-adjust idler arm pulley. Adjust belt tension, change belts, adjust airflow quickly • High efficiency gas heat with hot surface ignition for low heating energy costs, low maintenance and high reliability • Sloped sheet metal drain pans • 5-year limited compressor and heat exchanger warranty (12½ -17½ tons) • 1-year limited compressor and heat exchanger warranty (20 tons) Table PG-19-A — YCD-F, YCH-F - Ultra High Efficiency - Multi Speed Indoor Fan Cooling Heating Output Unit Power Supply Performance Capacity Capacity Dimensions (in.) Tons Model No. Volts/Phase/Hz EER3 (Btuh) (Btuh) H x W x L Shipping Max Fuse Size Weight or MaxDownflow1 (Ibs.) MCA** Circuit Breaker** Roofcurb YC* - Three Phase Low Heat 121/2 YC*151F3B0A 208-230/3/60 12.1 140,000 122,000 54 x 855/16 x 1225/162575 65 80 BAYCURB027B 15 YC*181F3B0A208-230/3/60 12.0 172,000 203,000 641/8 x 855/16 x 1225/162525 72 90 BAYCURB027B 171/2 YC*211F3B0A208-230/3/60 11.8 198,000 203,000 641/8 x 855/16 x 1225/162603 88 110 BAYCURB027B 20 YC*241F3B0A208-230/3/60 11.0 242,000 203,000 641/8 x 855/16 x 1225/162606 104 125 BAYCURB027B 25 YC*301F3B0A208-230/3/60 10.6 272,0002203,000 641/8 x 855/16 x 1225/162609 116 150 BAYCURB027B 121/2 YC*151F4B0A 460/3/60 12.1 140,000 122,000 54 x 855/16 x 1225/162575 32 40 BAYCURB027B 15 YC*181F4B0A 460/3/60 12.0 172,000 203,000641/8 x 855/16 x 1225/16 252536 45BAYCURB027B 171/2YC*211F4B0A 460/3/60 11.8 198,000 203,000641/8 x 855/16 x 1225/16 260342 50BAYCURB027B 20 YC*241F4B0A 460/3/60 11.0 242,000 203,000641/8 x 855/16 x 1225/16 260650 60BAYCURB027B 25 YC*301F4B0A 460/3/60 10.6272,0002203,000 641/8 x 855/16 x 1225/16 258956 70BAYCURB027B 121/2 YC*151FWB0A 575/3/60 12.1 140,000 122,000 54 x 855/16 x 1225/16 257525 30BAYCURB027B 15 YC*181FWB0A 575/3/60 12.0 172,000 203,000641/8 x 855/16 x 1225/162525 29 40 BAYCURB027B 171/2YC*211FWB0A 575/3/60 11.8 198,000 203,000641/8 x 855/16 x 1225/162603 36 45 BAYCURB027B 20 YC*241FWB0A 575/3/60 11.0 242,000 203,000641/8 x 855/16 x 1225/162606 42 50 BAYCURB027B 25 YC*301FWB0A575/3/60 10.6272,0002203,000 641/8 x 855/16 x 1225/16 258947 60BAYCURB027B YC* - Three Phase High Heat 121/2 YC*151F3C0A 208-230/3/60 12.1 140,000 203,000 54 x 855/16 x 1225/162575 65 80 BAYCURB027B 15 YC*181F3C0A208-230/3/60 12.0 172,000 284,000 641/8 x 855/16 x 1225/16 252572 90BAYCURB027B 171/2 YC*211F3C0A208-230/3/60 11.8 198,000 284,000 641/8 x 855/16 x 1225/16 2603 88 110BAYCURB027B 20 YC*241F3C0A208-230/3/60 11.0 242,000 324,000 641/8 x 855/16 x 1225/16 2606104 125BAYCURB027B 25 YC*301F3C0A208-230/3/60 10.6 272,000 324,000 641/8 x 855/16 x 1225/16 2609116 150BAYCURB027B 121/2 YC*151F4C0A 460/3/60 12.1 140,000 203,000 54 x 855/16 x 1225/162575 32 40 BAYCURB027B 15 YC*181F4C0A 460/3/60 12.0 172,000 284,000641/8 x 855/16 x 1225/162525 36 45 BAYCURB027B 171/2YC*211F4C0A 460/3/60 11.8 198,000 284,000641/8 x 855/16 x 1225/16 260342 50BAYCURB027B 20 YC*241F4C0A 460/3/60 11.0 242,000 324,000641/8 x 855/16 x 1225/162606 50 60 BAYCURB027B 25 YC*301F4C0A 460/3/60 10.6 272,000 324,000641/8 x 855/16 x 1225/16 258956 70BAYCURB027B 121/2 YC*151FWC0A 575/3/60 12.1 140,000 203,000 54 x 855/16 x 1225/162575 25 30 BAYCURB027B 15 YC*181FWC0A 575/3/60 12.0 172,000 284,000641/8 x 855/16 x 1225/162525 29 40 BAYCURB027B 171/2YC*211FWC0A 575/3/60 11.8 198,000 284,000641/8 x 855/16 x 1225/162603 36 45 BAYCURB027B 20 YC*241FWC0A 575/3/60 11.0 242,000 324,000641/8 x 855/16 x 1225/162606 42 50 BAYCURB027B 25 YC*301FWC0A 575/3/60 10.6 272,000 324,000641/8 x 855/16 x 1225/16 258947 60BAYCURB027B 1For Downflow units only. 2278,000 in the Horizontal airflow configuration. 3Downflow/Horizontal * Digit 3 D=Downflow or H=Horizontal. ** Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-19 Effective 7/1/12 14-1011-28 Packaged Gas/Electric with ReliaTel™ Controls 12½-25 Tons, R-410A 12½ - 25 Ton YCD-F — Downflow 12½ - 25 Ton YCH-F — Horizontal • Scroll compressors on all units • ReliaTel™ control features are listed on page PC-16 • Operating charge of R-410A • Built-in anti-short cycle timer, time delay relay and minimum on time controls • Low Ambient to 0°F standard • High efficiency drum and tube heat exchanger • Color coded and numbered wiring • Two inch throwaway filters on both YCH and YCD to clean air and keep coil maintenance low • Simple U-shaped airflow pattern results in very low airside energy requirement • Quick-Access doors and single side access make servicing much faster for lower maintenance costs • Quick-adjust idler arm pulley. Adjust belt tension, change belts, adjust airflow quickly • High efficiency gas heat with hot surface ignition for low heating energy costs, low maintenance and high reliability • Sloped sheet metal drain pans • 5-year limited compressor and heat exchanger warranty (12½ -17½ tons) • 1-year limited compressor and heat exchanger warranty (20 tons) Table PG-20-A — YCD-F, YCH-F - Standard Efficiency Unit Power Supply Tons Model No. Volts/Phase/Hz Cooling Heating Output Performance Capacity Capacity EER (Btuh) (Btuh) Shipping Max Fuse Size Dimensions (in.) Weight or MaxDownflow1 H x W x L (Ibs.) MCA** Circuit Breaker** Roofcurb YC* - Three Phase Low Heat 121/2 YC*150F300B208-230/3/60 11.0 140,000122,000501/8 x 715/8 x 1075/16178168 80 BAYCURB026B 15 YC*180F300B 208-230/3/60 11.0 176,000 203,000 54 x 855/16 x 1225/16 228175 100 BAYCURB027B 171/2 YC*210F300B 208-230/3/60 11.0 193,000 203,000 54 x 855/16 x 1225/16 229293 125 BAYCURB027B 20 YC*240F300B 208-230/3/60 10.0 240,000 203,000 54 x 855/16 x 1225/16 2353108 125 BAYCURB027B 25 YC*300F300B 208-230/3/60 10.0 272,000 203,000 54 x 855/16 x 1225/16 2337124 150 BAYCURB027B 121/2YC*150F400B 460/3/60 11.0 140,000122,000501/8 x 715/8 x 1075/16178132 40 BAYCURB026B 15 YC*180F400B 460/3/60 11.0 176,000 203,000 54 x 855/16 x 1225/16 228128 50 BAYCURB027B 171/2 YC*210F400B 460/3/60 11.0 193,000 203,000 54 x 855/16 x 1225/16 229244 60 BAYCURB027B 20 YC*240F400B 460/3/60 10.0 240,000 203,000 54 x 855/16 x 1225/16 235352 70 BAYCURB027B 25 YC*300F400B 460/3/60 10.0 272,000 203,000 54 x 855/16 x 1225/16 233759 70 BAYCURB027B 121/2YC*150FW00B 575/3/60 11.0 140,000122,000501/8 x 715/8 x 1075/16178124 30 BAYCURB026B 15 YC*180FW00B 575/3/60 11.0 176,000 203,000 54 x 855/16 x 1225/16 228131 40 BAYCURB027B 171/2 YC*210FW00B 575/3/60 11.0 193,000 203,000 54 x 855/16 x 1225/16 229235 50 BAYCURB027B 20 YC*240FW00B 575/3/60 10.0 240,000 203,000 54 x 855/16 x 1225/16 235344 60 BAYCURB027B 25 YC*300FW00B 575/3/60 10.0 272,000 203,000 54 x 855/16 x 1225/16 233748 60 BAYCURB027B YC* - Three Phase High Heat 121/2 YC*150F300B208-230/3/60 11.0 140,000203,000501/8 x 715/8 x 1075/16178168 80 BAYCURB026B 15 YC*180F300B 208-230/3/60 11.0 176,000 284,000 54 x 855/16 x 1225/16 228175 100 BAYCURB027B 171/2 YC*210F300B 208-230/3/60 11.0 193,000 284,000 54 x 855/16 x 1225/16 229293 125 BAYCURB027B 20 YC*240F300B 208-230/3/60 10.0 240,000 324,000 54 x 855/16 x 1225/16 2353108 125 BAYCURB027B 25 YC*300F300B 208-230/3/60 10.0 272,000 324,000 54 x 855/16 x 1225/16 2337124 150 BAYCURB027B 121/2YC*150F400B 460/3/60 11.0 140,000203,000501/8 x 715/8 x 1075/16178132 40 BAYCURB026B 15 YC*180F400B 460/3/60 11.0 176,000 284,000 54 x 855/16 x 1225/16 228128 50 BAYCURB027B 171/2 YC*210F400B 460/3/60 11.0 193,000 284,000 54 x 855/16 x 1225/16 229244 60 BAYCURB027B 20 YC*240F400B 460/3/60 10.0 240,000 324,000 54 x 855/16 x 1225/16 235352 70 BAYCURB027B 25 YC*300F400B 460/3/60 10.0 272,000 324,000 54 x 855/16 x 1225/16 233759 70 BAYCURB027B 121/2YC*150FW00B 575/3/60 11.0 140,000203,000501/8 x 715/8 x 1075/16178124 30 BAYCURB026B 15 YC*180FW00B 575/3/60 11.0 176,000 284,000 54 x 855/16 x 1225/16 228131 40 BAYCURB027B 171/2 YC*210FW00B 575/3/60 11.0 193,000 284,000 54 x 855/16 x 1225/16 229235 50 BAYCURB027B 20 YC*240FW00B 575/3/60 10.0 240,000 324,000 54 x 855/16 x 1225/16 235344 60 BAYCURB027B 25 YC*300FW00B 575/3/60 10.0 272,000 324,000 54 x 855/16 x 1225/16 233748 60 BAYCURB027B 1For Downflow units only. * Digit 3 D=Downflow or H=Horizontal. ** Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-20 Effective 7/1/12 14-1011-28 Packaged Gas/Electric with ReliaTel™ Controls 12½-25 Tons, R-410A 12½ - 25 Ton YCD-F — Downflow 12½ - 25 Ton YCH-F — Horizontal • Scroll compressors on all units • ReliaTel™ control features are listed on page PC-16 • Operating charge of R-410A • Built-in anti-short cycle timer, time delay relay and minimum on time controls • Low Ambient to 0°F standard • High efficiency drum and tube heat exchanger • Color coded and numbered wiring • Two inch throwaway filters on both YCH and YCD to clean air and keep coil maintenance low • Simple U-shaped airflow pattern results in very low airside energy requirement • Quick-Access doors and single side access make servicing much faster for lower maintenance costs • Quick-adjust idler arm pulley. Adjust belt tension, change belts, adjust airflow quickly • High efficiency gas heat with hot surface ignition for low heating energy costs, low maintenance and high reliability • Sloped sheet metal drain pans • 5-year limited compressor and heat exchanger warranty (12½ -17½ tons) • 1-year limited compressor and heat exchanger warranty (20 tons) Table PG-21-A — YCD-F, YCH-F - Standard Efficiency - Multi Speed Indoor Fan Unit Power Supply Performance Tons Model No. Volts/Phase/Hz EER Cooling Heating Output Capacity Capacity Dimensions (in.) (Btuh) (Btuh) H x W x L Shipping Max Fuse Size Weight or MaxDownflow1 (Ibs.) MCA** Circuit Breaker** Roofcurb YC* - Three Phase Low Heat 121/2 YC*150F3B0B208-230/3/60 11.0 140,000122,000 501/8 x 715/8 x 1075/161806 64 80 BAYCURB026B 15 YC*180F3B0B 208-230/3/60 11.0 176,000 203,000 54 x 855/16 x 1225/162306 75 100BAYCURB027B 171/2 YC*210F3B0B 208-230/3/60 11.0 193,000 203,000 54 x 855/16 x 1225/162317 93 125BAYCURB027B 20 YC*240F3B0B 208-230/3/60 10.0 240,000 203,000 54 x 855/16 x 1225/162378108 125BAYCURB027B 25 YC*300F3B0B 208-230/3/60 10.0 272,000 203,000 54 x 855/16 x 1225/162402124 150BAYCURB027B 121/2 YC*150F4B0B 460/3/60 11.0 140,000122,000 501/8 x 715/8 x 1075/161806 31 40 BAYCURB026B 15 YC*180F4B0B 460/3/60 11.0 176,000 203,000 54 x 855/16 x 1225/162306 28 50 BAYCURB027B 171/2 YC*210F4B0B 460/3/60 11.0 193,000 203,000 54 x 855/16 x 1225/162317 44 60 BAYCURB027B 20 YC*240F4B0B 460/3/60 10.0 240,000 203,000 54 x 855/16 x 1225/162378 52 70 BAYCURB027B 25 YC*300F4B0B 460/3/60 10.0 272,000 203,000 54 x 855/16 x 1225/162382 59 70 BAYCURB027B 121/2 YC*150FWB0B 575/3/60 11.0 140,000122,000 501/8 x 715/8 x 1075/161806 23 30 BAYCURB026B 15 YC*180FWB0B 575/3/60 11.0 176,000 203,000 54 x 855/16 x 1225/162306 31 40 BAYCURB027B 171/2 YC*210FWB0B 575/3/60 11.0 193,000 203,000 54 x 855/16 x 1225/162317 35 50 BAYCURB027B 20 YC*240FWB0B 575/3/60 10.0 240,000 203,000 54 x 855/16 x 1225/162378 44 60 BAYCURB027B 25 YC*300FWB0B 575/3/60 10.0 272,000 203,000 54 x 855/16 x 1225/162382 48 60 BAYCURB027B YC* - Three Phase High Heat 121/2 YC*150F3C0B208-230/3/60 11.0 140,000 203,000 501/8 x 715/8 x 1075/161806 64 80 BAYCURB026B 15 YC*180F3C0B 208-230/3/60 11.0 176,000 284,000 54 x 855/16 x 1225/162306 75 100BAYCURB027B 171/2 YC*210F3C0B 208-230/3/60 11.0 193,000 284,000 54 x 855/16 x 1225/162317 93 125BAYCURB027B 20 YC*240F3C0B 208-230/3/60 10.0 240,000 324,000 54 x 855/16 x 1225/162378108 125BAYCURB027B 25 YC*300F3C0B 208-230/3/60 10.0 272,000 324,000 54 x 855/16 x 1225/162402124 150BAYCURB027B 121/2 YC*150F4C0B 460/3/60 11.0 140,000203,000 501/8 x 715/8 x 1075/161806 31 40 BAYCURB026B 15 YC*180F4C0B 460/3/60 11.0 176,000 284,000 54 x 855/16 x 1225/162306 28 50 BAYCURB027B 171/2 YC*210F4C0B 460/3/60 11.0 193,000 284,000 54 x 855/16 x 1225/162317 44 60 BAYCURB027B 20 YC*240F4C0B 460/3/60 10.0 240,000 324,000 54 x 855/16 x 1225/162378 52 70 BAYCURB027B 25 YC*300F4C0B 460/3/60 10.0 272,000 324,000 54 x 855/16 x 1225/162382 59 70 BAYCURB027B 121/2 YC*150FWC0B 575/3/60 11.0 140,000203,000 501/8 x 715/8 x 1075/161806 23 30 BAYCURB026B 15 YC*180FWC0B 575/3/60 11.0 176,000 284,000 54 x 855/16 x 1225/162306 31 40 BAYCURB027B 171/2 YC*210FWC0B 575/3/60 11.0 193,000 284,000 54 x 855/16 x 1225/162317 35 50 BAYCURB027B 20 YC*240FWC0B 575/3/60 10.0 240,000 324,000 54 x 855/16 x 1225/162378 44 60 BAYCURB027B 25 YC*300FWC0B 575/3/60 10.0 272,000 324,000 54 x 855/16 x 1225/162382 48 60 BAYCURB027B 1For Downflow units only. * Digit 3 D=Downflow or H=Horizontal. ** Information subject to change. Please confirm with current Product Data/Service Facts for current factory production. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-21 Effective 7/1/12 14-1011-28 Packaged Gas/Electric with ReliaTel™ Controls 12½-25 Tons FIOPS Table PG-22-A — Factory Installed Accessories12 For Complete list of all Factory Installed Options, please refer to the FIOPS section of this book. Digit Description 1-9 10 11-12 Main Assembly Factory Installed Options No Options 0 Downflow Economizer3 A Oversized Motor B Downflow Economizer and Oversized Motor3 C TXV/Face - Split Evaporator H Oversized Motor and TXV/Face -Split Evaporator J Downflow Economizer, Oversized Motor and TXV/Face K Split Evaporator3 Downflow Economizer with TXV/Face - Split Evaporator3 L Reheat Coil4 M Downflow Economizer with Reheat Coil34 N Oversized Motor and Reheat Coil4 P Downflow Economizer, Oversized Motor and R Reheat Coil 34 Minor Design and Service Sequence ** Order Number Used With YC*150-301 YCD150-301 YC*150-241 YCD150-241 YCD151, 181, 211, 241, 301 YCD151, 181, 211, 241 YCD151, 181, 211, 241 YCD151, 181, 211, 241, 301 YCD151, 181, 241 YCD151, 181, 241 YCD151, 181, 241 YCD151, 181, 241 1Price includes accessory and factory installation. 2Four (4) week shipping approximately. 3 Some field set up required. 4 All 10th digit model numbers including reheat coil (M,N,P,R) require additional factory installed options; ReliaTel™ options module (FIYABRD002B), Frostat (FIYLOAM023A or FIYLOAM031A), and 2" pleated filters (refer to FIOPS section for appropriate model number usage). For these or any Factory Installed Options not included in 10th digit model number, digits 1-3 must be YFD. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-22 Effective 7/1/12 14-1011-28 Packaged Gas/Electric with ReliaTel™ Controls 12½-25 Tons Accessories Table PG-23-A — Field Installed Accessories — For complete list of of All Factory Installed Options refer to FIOPS section of this book. Model Number Description Used With BAYABRD002B8.............ReliaTel™ Options Module.....................................YC*150F-YC*301F BAYBCIR001A................. Bacnet™ Communication Interface...................... ReliaTel™ Controller (BCI-R) ASYSTAT713A................ CO2 Sensor Wall Mounted.......................................YC*150F-YC*301F ASYSTAT715A................ CO2 Sensor Duct Mounted......................................YC*150F-YC*301F BAYCURB026B56 ....... Downflow Only Roof Curb ......................................YCD150F BAYCURB027B56........ Downflow Only Roof Curb ......................................YCD151F-YCD301F, YCD180F-300F BAYDFPS005A78........ Clogged Filter Switch (MERV 7)..............................YC*150F-YC*301F BAYDFPS006A78........ Fan Failure Switch...................................................YC*150F-YC*301F BAYDFPS031A............... Clogged Filter Switch (MERV 13)............................YC*150F-YC*301F BAYDMPR029C.............. 0-25% Manual Outside Air Damper........................YC*150F-YC*301F BAYDMPR057A.............. 0-50% Motorized Outside Air Damper....................YC*150F BAYDMPR058A.............. 0-50% Motorized Outside Air Damper....................YC*151F-YC*301F, YCD180F-300F BAYECON089A8........... Downflow Economizer with Barometric Relief.........YCD150F BAYECON090A8........... Downflow Economizer with Barometric Relief.........YCD151F-YCD301F, YCD180F-300F BAYECON091A............... Horizontal Economizer ...........................................YCH150F BAYECON092A............... Horizontal Economizer ...........................................YCH151F-YCH301F, YHC180F-300F BAYENTH007A12........ Reference Enthalpy Kit............................................All BAYECON089A-092A BAYENTH008A13........ Comparative Enthalpy Kit .......................................All BAYECON089A-092A BAYFRST003A................High Temperature Stat........................................... YC*150F-YC*301F BAYGARD144A8........... Tool-less Hail Guard................................................YC*150F BAYGARD145A8........... Tool-less Hail Guard................................................YC*151F, YC*180F, YC*210F, YC*240F, YC*300F BAYGARD150A8........... Tool-less Hail Guard................................................YC*211, YC*241, YC*301, YC*181F BAYHSDR005B4........... High Static Drive......................................................YC*150F, YC*180F, YC*151F, YC*181F BAYHSDR010A............... High Static Drive......................................................YC*211F, YC*241F, YC*300F BAYHSDR011A............... High Static Drive......................................................YC*210, YC*240, YC*301F 1 Kit contains all necessary parts to achieve desired level of Enthalpy Control. 2 Reference Enthalpy senses outside temperature/humidity. 3 Comparative Enthalpy senses outside temperature/humidity and inside return/mixed air temperature/humidity. 4 High static drive and oversized motors are mutually exclusive, Do Not Combine. 5 See Accessory IOM for operational characteristics. 6Clarksville Manufacturing has a no-return policy for this roof curb. 7BAYABRD002 is required when ordering BAYDFPS005A or 006A, BAYTUBE008A or 009A and BAYLOAM023A or BAYVNOR002B. 8Field or factory installed option. * Either horizontal or downflow models For additional Controls Information: See ReliaTel™ and Micro Control features on PC-16 and PC-17. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-23 Effective 7/1/12 14-1011-28 Packaged Gas/Electric with ReliaTel™ Controls 12½-25 Tons Accessories Table PG-24-A — Field Installed Accessories — For complete list of of All Factory Installed Options refer to FIOPS section of this book. Model Number Description Used With BAYHSMT039B14.........5HP Oversized Motor Kit (208-230/460V)................................. YC*150F BAYHSMT040B4............ 5HP Oversized Motor Kit (575V).............................................. YC*150F BAYHSMT055B14.........5HP Oversized Motor Kit (208-230/460V)................................. YC*180 BAYHSMT042A24.........7-1/2HP Oversized Motor Kit (575V) ........................................ YC*210F, YC*240F, YC*211F, YC*241F BAYHSMT072A24.........7-1/2HP Oversized Motor Kit (575V)......................................... YC*180F, YC*181F BAYHSMT098A24.........7-1/2HP Oversized Motor Kit (230V)......................................... YC*211F, YC*241F BAYHSMT099A24.........7-1/2HP Oversized Motor Kit (460V)......................................... YC*211F, YC*241F BAYLOAM023A3........... Evaporator Defrost Control.................................................... YC*150F, YC*151F, YC*180F, YC*181F, YC*210F, YC*240F, YC*300F BAYLOAM031A.............. Evaporator Defrost Control.................................................... YC*211F, YC*241F, YC*301F BAYLPKT018A.................LP Conversion Kit...................................................................... YC*150F-YC*301F BAYLSDR004A2.............Low Static Drive......................................................................... YC*150F, YC*180F, YC*210F, YC*211F, YC*240F, YC*241F BAYLSDR002A2.............Low Static Drive......................................................................... YC*151F, YC*181F, YC*300F BAYPWRX029A.............. Power Exhaust for all Voyagers 12½-25 Ton 230V units......... Downflow Only BAYPWRX030A.............. Power Exhaust for all Voyagers 12½-25 Ton 460V units......... Downflow Only BAYPWRX031A.............. Power Exhaust for all Voyagers 12½-25 Ton 575V units......... Downflow Only BAYSERV001A................Selective Resistance Service Tester.......................................... YC*150F-YC*301F BAYSTAT023....................Remote Potentiometer............................................................... YC*150F-YC*301F BAYTUBE008A34.........Discharge Air Sensing Kit.......................................................... YCD150F-YCD301F BAYTUBE009A34.........Discharge Air Sensing Kit.......................................................... YCH150F-YCH301F BAYQACB044A................Adapter Curb.............................................................................. BAYCURB026A/B to BAYCURB027A/B BAYVNOR002B3........... Ventilation Override Kit........................................................... YC*150F-YC*301F 1 High static drive and oversized motors are mutually exclusive, Do Not Combine. 2 Low static drive and oversized motors are mutually exclusive, Do Not Combine. 3BAYABRD002 is required when ordering BAYDFPS005A or 006A, BAYTUBE008A or 009A and BAYLOAM023A, BAYLOAM031A or BAYVNOR002B. 4Field or factory installed option. * Either horizontal or downflow models Packaged Gas/Electric with ReliaTel™ Controls 12½-25 Tons, R-22, R-410A Zone Sensors / Thermostats Table PG-24-A — Zone Sensors — ReliaTel™ Model Number ASYSTAT106A ASYSTAT108A ASYSTAT111A ASYSTAT777A ASYSTAT710A ASYSTAT711A BAYMTPL110A Description Single Setpoint Manual Changeover Dual Setpoint Manual or Automatic Changeover Remote Room Sensor Programmable Night Setback Wall Mounted Humidity Sensor Duct Mounted Humidity Sensor Retrofit Wall Cover Plate Kit 7.25" x 6.0" Used With YC*150-301 YC*150-301 ASYSTAT777A YC*150-301 YFD151,181,241 (with Reheat) YFD151,181,241 (with Reheat) ASYSTAT777A For additional Controls Information: See ReliaTel™ and Micro Control features on PC-16 and PC-17. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-24 Effective 7/1/12 14-1011-28 Packaged Unit Accessories 12½-25 Tons 12 1/2 – 25 Ton Packaged Gas/Electric, Electric/Electric and Heat Pump Dedicated Airflow Design OR Typical Downflow Application G A E D QA Field Fabricated Duct Field Fabricated Duct C A S G E Typical Horizontal Application Factory Supplied Accessories Factory Supplied AAccessories Unit UnitYCD/H, TCD/H, WCD/H YCD/H, TCD/H, WCD/H Coil Guard (3 – 7(BAYGARD) 1/2 Ton) G Coil Guard (BAYGARD) Economizer (Downflow and and Economizer (Downflow E Horizontal) (BAYECON) Horizontal) (BAYECON) D Fresh Air Damper (BAYDMPR) Manual (3 – 25 Ton) (0 – 25%) Fresh Air Damper (BAYDMPR) D Motorized (5 – 25 Ton Only) (0 – 50%) S Sensor/Thermostat C Sensor/Thermostat S Curb (BAYCURB) Manual (0-25%) Motorized (0-50%) Curb (BAYCURB) Quick Adapt Curb . . . Field Supplied QA C (8 1/2 – 25 Ton Only) (BAYCURB) Quick Adapt Curb...Field Supplied Power Exhaust PE QA (6 1/4 – 25 Ton Only) (BAYPWRX) (BAYCURB) Field Fabricated Duct PE Power Exhaust (BAYPWRX) Power Exhaust Accessory Typical Economizer Application PE For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. PG-25 Effective 7/1/12 14-1011-28 Factory Installed Options Commercial Packaged Units 12 ½-25 Tons* American Standard Heating & Air Conditioning offers a variety of factory installed options (FIOPS) for the light commercial packaged rooftop product line. These options are in addition to the standard factory installed options, i.e., downflow economizer and oversized motors. Black Epoxy Coated Condenser Coil – Black Epoxy coil protection is a factory-applied, thermoset vinyl coating that is bonded to the aluminum fin stock prior to the fin stamping process. The pre-coated coils are an economical option for protection in mildly corrosive environments. Through the Base Gas Piping – With this option, provision will be made in the unit for installing through the base gas piping. The option will have all piping necessary including a pre-assembled, black steel, manual gas shut-off valve, elbows and union. The manual shut-off valve shall include a 1/8 inch NPT pressure tap. This assembly will require minor field labor to install. Dehumidification Option – The dehumidification (hot gas reheat) option is a factory-installed option that provides increased dehumidification. The option consists of a hot-gas reheat coil located on the leaving air side of the evaporator coil prepiped and circuited. The option is equipped with crankcase heater(s), low pressure switch(es), Frostat™, and a thermostatic expansion valve(s) (TXV) as standard. This option is available for all 3 – 25 ton gas/electric units, and can only be ordered when the Through the Base Electrical Option with Disconnect or Circuit Breaker is ordered. Discharge Air Sensing Kit – This option provides true discharge air sensing in heating models. This sensor is a status indicator readable through Tracer® or Tracker®. The kit is functional only with the ReliaTel™ Module. Differential Pressure Switches – A dedicated differential pressure switch is available to achieve active fan failure indication and/or clogged filter indication. These indications will be registered on a zone sensor with status indication lights. This option is available for all 3 – 25 ton models. Hail Guards – Hail protection quality coil guards can be either factory or field-installed for condenser coil protection. High Efficiency Motors – This option is available with efficiency ratings from 86.5 up to 91.0. Not available for all models. Electric Heaters – Factory installed and wired electric heaters are available for all 230, 460, and 575 volt 3-phase horizontal and downflow 3 – 25 ton models. If ordering the Through the Base Electrical option with an Electric Heater, the heater must be factory installed. Supply and/or Return Air Smoke Detector – With this option installed, if smoke is detected, all unit operation will be shut down. Reset will be manual at the unit. Return Air Smoke Detectors require minimum allowable airflow when used with certain models. See the Installation, Operation, and Maintenance (IOM) manual for the models affected and the minimum allowable airflow required. This option is available on all 12½-25 tons models. Hinged Access Doors – Sheet metal hinges are available factory installed on the Filter/Evaporator Access Door and the Compressor/ Control Access Door of all 3 – 25 ton units. Frostat – This factory or field installed option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 10°F. The temperature will need to rise to 50°F before closing. This option should be utilized in low airflow or high outside air applications. Powered or Unpowered Convenience Outlet – This option is a GFCI, 120 volt/15 amp, 2 plug, convenience outlet, either powered or unpowered. When the convenience outlet is powered, a service receptacle disconnect will be available. The convenience outlet is powered from the line side of the disconnect or circuit breaker, and therefore will not be affected by the position of the disconnect or circuit breaker. Through the Base Utilities Access – An electrical service entrance shall be provided allowing electrical access for both control and main power connection inside the curb and through the base of the unit. Option will allow for field installation of liquid-tight conduit and an external field installed disconnect switch. This option is available for all 3 – 25 ton units and can only be ordered when the Through the Base Electrical with either the Disconnect Switch or Circuit Breaker option is ordered. Novar Unit Controls – Novar rooftop unit controls will be factor installed and tested. The Novar electronic thermostat module will interface to the unit microprocessor and will control the unit to the desired stage of cooling or heating. The Novar electronic thermostat module will monitor the following unit information: fan failure status, cooling stage 1-on status, cooling stage 2 on status, heating on status, clogged filter status or unit shutdown status, and discharge air temperature. The Novar electronic thermostat module will have the ability to enable the unit mounted economizer. Reference or Comparative Enthalpy – When a factory installed Downflow Economizer is ordered, an option will be to factory install either Reference or Comparative Enthalpy Control. Through the Base Electrical with Circuit Breaker – This option is a factory installed thermal magnetic, molded case, HACR Circuit Breaker with provisions for through the base electrical connections. The circuit breaker will be installed in a water tight enclosure in the unit with access through a swinging door. Factory wiring will be provided from the switch to the unit high voltage terminal block. The circuit breaker will provide overcurrent protection, be sized per NEC and UL guidelines, and be agency recognized by UL/CSA. Novar Return Air Sensor – This option, when used in conjunction with Novar Controls, will contain a factory provided wired zone temperature sensor located in the return air stream. This option is available for all 3 – 25 ton downflow models. Either a Circuit Breaker or a Disconnect Switch (not both) must be ordered when ordering the Through the Base Electrical option. Two Inch Pleated Filters – Two inch pleated media filters shall be available on all 12½-25 ton models. Thermal Expansion Valve (TXV) and Face Split Evaporator – All units shall have a short orifice refrigerate control metering device. For more exact refrigerant flow, when using units in low airflow or high outside air applications, a Thermal Expansion Valve option shall be available. This is available on High Efficiency Gas/Cooling units only. Through the Base Electrical with Disconnect Switch – Factory installed 3-pole, molded case disconnect switch with provisions for through the base electrical connections are available. The disconnect switch will be installed in the unit in a water tight enclosure with access through a swinging door. Factory wiring will be provided from the switch to the unit high voltage terminal block. The switch will be UL/CSA agency recognized. Note: The disconnect switch will be sized per NEC and UL guidelines but will not be used in place of unit overcurrent protection. Before Ordering: Not all factory options are offered for single phase units. This option is available for all 230, 460 and 575 volt, 3-phase 3 – 25 ton models. Either a Circuit Breaker or a Disconnect Switch (not both) must be ordered when ordering the Through the Base Electrical option. Please contact the Clarksville, TN Support Team for latest updates of factory installed options and ordering instructions. Call (931) 645-6471 and ask to be connected to the Light Commercial Product Support Team. (888) 279-0543 * Some FIOPs available only for certain tonnages, unit functions, or efficiencies. FIOPS-1 Effective 7/1/12 14-1011-28 Downflow/Horizontal Packaged Cooling, Packaged Gas/Electric/Packaged Heat Pump Factory Installed Options (FIOPS) Table FIOPS-2-A — Accessories Model Number Description Used With Circuit Breaker Must be used with Through-the-Base Electrical option. FIYUCB3175A Unit Mounted Circuit Breaker FIYUCB3200A Unit Mounted Circuit Breaker FIYUCB3225A Unit Mounted Circuit Breaker FIYUCB3250A Unit Mounted Circuit Breaker FIYUCB4015A Unit Mounted Circuit Breaker FIYUCB4020A Unit Mounted Circuit Breaker FIYUCB4025A Unit Mounted Circuit Breaker FIYUCB4030A Unit Mounted Circuit Breaker FIYUCB4035A Unit Mounted Circuit Breaker FIYUCB4040A Unit Mounted Circuit Breaker FIYUCB4045A Unit Mounted Circuit Breaker FIYUCB4050A Unit Mounted Circuit Breaker FIYUCB4060A Unit Mounted Circuit Breaker FIYUCB4070A Unit Mounted Circuit Breaker FIYUCB4080A Unit Mounted Circuit Breaker FIYUCB4090A Unit Mounted Circuit Breaker FIYUCB4100A Unit Mounted Circuit Breaker FIYUCB4110A Unit Mounted Circuit Breaker FIYUCB4125A Unit Mounted Circuit Breaker FIYUCB4150A Unit Mounted Circuit Breaker FIYUCB6110A Unit Mounted Circuit Breaker FIYUCB6125A Unit Mounted Circuit Breaker Convenience Outlet Must be ordered with Through-the-Base Electrical option and either Unit Mounted Disconnect or Circuit Breaker. FIYCOPO201A Powered, 120V Convenience Outlet, 230V TC/YCD150-301*3, WCD150-240*3 FIYCOPO202A Powered, 120V Convenience Outlet, 460V TC/YCD150-301*4, WCD150-240*4 FIYCOPO205A Powered, 120V Convenience Outlet, 575V TC/YCD150-301*W, WCD150-240*W FIYCOPO301A Powered, 120V Convenience Outlet, 230V TC/YCH150-301*3, WCH150-240*A3 FIYCOPO302A Powered, 120V Convenience Outlet, 460V TC/YCH150-301*4, WCH150-240*A4 FIYCOPO303A Powered, 120V Convenience Outlet, 575V TC/YCH150-301*W, WCH150-240*AW FIYCOUP201A Unpowered, 115V Convenience Outlet TC/YCD150-301, WCD150-240 FIYCOUP301A Unpowered, 115V Convenience Outlet TC/YCH150-301, 180-300E, WCD150-240 Discharge Air Sensing Kit Used for true discharge air sensing in heating models. Functional only with ReliaTelTM Options Module (FIYABRD002B). FIYTUBE008A Discharge Air Sensing Kit (All Voltages) TC/YCD150-301*, WCD150-240 FIYTUBE009A Discharge Air Sensing Kit (All Voltages) TC/YCH150-301*, WCH150-240 Disconnect Switch Must be used with Through-the-Base Electrical option. Cannot be fused. FIYUDC3250A Unit Mounted Disconnect Switch FIYUDC4100A Unit Mounted Disconnect Switch FIYUDC4150A Unit Mounted Disconnect Switch FIYUDC6100A Unit Mounted Disconnect Switch Economizer Actuator Logic Module FIYLGCM001A is required when ordering the following Factory Installed Options (FIOPs). Reference Enthalpy (FIYENTH007A), Comparative Enthalpy (FIYENTH008A), Novar Controls (FIYCNTL013A, 015A,016A, 017A,018A, 019A). FIYLGCM001A Economizer Actuator Logic Module All Packaged Rooftop Units 12½-25 Tons with economizers and the above mentioned FIOPs. (FIOP #s) FIOPS-2 Effective 7/1/12 14-1011-28 Downflow/Horizontal Packaged Cooling, Packaged Gas/Electric/Packaged Heat Pump Factory Installed Options (FIOPS) Table FIOPS-3-A — Accessories Model NumberDescription Electric Heat - Cooling Must be factory installed when using with Through-the-Base Electrical option. FIDHTRK318A Factory Installed 18KW Electric Heat FIDHTRK336A Factory Installed 36KW Electric Heat FIDHTRK354A Factory Installed 54KW Electric Heat FIDHTRK372A Factory Installed 72KW Electric Heat FIDHTRK427A Factory Installed 27KW Electric Heat FIDHTRK436A Factory Installed 36KW Electric Heat FIDHTRK454A Factory Installed 54KW Electric Heat FIDHTRK472A Factory Installed 72KW Electric Heat FIDHTRKW18A Factory Installed 18KW Electric Heat FIDHTRKW54A Factory Installed 54KW Electric Heat FIDHTRKW72A Factory Installed 72KW Electric Heat FIDHTRL336A Factory Installed 36KW Electric Heat FIDHTRL354A Factory Installed 54KW Electric Heat FIDHTRL418A Factory Installed 18KW Electric Heat FIDHTRL427A Factory Installed 27KW Electric Heat FIDHTRL436A Factory Installed 36KW Electric Heat FIDHTRL454A Factory Installed 54KW Electric Heat FIDHTRLW54A Factory Installed 54KW Electric Heat FIDHTRMW36A Factory Installed 36KW Electric Heat FIHHTRM318A Factory Installed 18KW Electric Heat FIHHTRM336A Factory Installed 36KW Electric Heat FIHHTRM354A Factory Installed 54KW Electric Heat FIHHTRM418A Factory Installed 18KW Electric Heat FIHHTRM436A Factory Installed 36KW Electric Heat FIHHTRM454A Factory Installed 54KW Electric Heat FIHHTRMW18A Factory Installed 18KW Electric Heat FIHHTRMW36A Factory Installed 36KW Electric Heat FIHHTRMW54A Factory Installed 54KW Electric Heat FIHHTRN318A Factory Installed 18KW Electric Heat FIHHTRN336A Factory Installed 36KW Electric Heat FIHHTRN354A Factory Installed 54KW Electric Heat FIHHTRN372A Factory Installed 72KW Electric Heat FIHHTRN418A Factory Installed 18KW Electric Heat FIHHTRN436A Factory Installed 36KW Electric Heat FIHHTRN454A Factory Installed 54KW Electric Heat FIHHTRN472A Factory Installed 72KW Electric Heat FIHHTRNW18A Factory Installed 18KW Electric Heat FIHHTRNW54A Factory Installed 54KW Electric Heat FIHHTRNW72A Factory Installed 72KW Electric Heat FIHHTRP336A Factory Installed 36KW Electric Heat FIHHTRP354A Factory Installed 54KW Electric Heat FIHHTRP436A Factory Installed 36KW Electric Heat FIHHTRP454A Factory Installed 54KW Electric Heat FIHHTRPW36A Factory Installed 36KW Electric Heat FIHHTRPW54A Factory Installed 54KW Electric Heat FIHHTRQ336A Factory Installed 36KW Electric Heat FIHHTRQ354A Factory Installed 54KW Electric Heat FIHHTRQ436A Factory Installed 36KW Electric Heat FIHHTRQ454A Factory Installed 54KW Electric Heat FIHHTRQW54A Factory Installed 51KW Electric Heat FIOPS-3 Effective 7/1/12 14-1011-28 Downflow/Horizontal Packaged Cooling, Packaged Gas/Electric/Packaged Heat Pump Factory Installed Options (FIOPS) Table FIOPS-4-A — Accessories Model Number Description Used With Enthalpy Kits FIYENTH007A Reference Enthalpy Downflow Units w/A,C or G in 10th Digit FIYENTH008A Comparative Enthalpy Downflow Units w/A,C or G in 10th Digit Filter & Control Access FIYHNG009A Hinged Filter/Evap. And Comp./Control Access Door WCD150-180 FIYHNG203A Hinged Filter/Evap. And Comp./Control Access Door WCH150-180 FIYHNG204A Hinged Filter/Evap. And Comp./Control Access Door WCD240 FIYHNG205A Hinged Filter/Evap. And Comp./Control Access Door WCH240 FIYHNGE302A Hinged Filter/Evap. And Comp./Control Access Door TCD/YCD 180F, 210F, 240F, 180F, 300F FIYHNGE303A Hinged Filter/Evap. And Comp./Control Access Door TCH/YCH 180F, 210F, 240F, 180F, 300F FIYHNGE304A Hinged Filter/Evap. And Comp./Control Access Door TCD/YCD 181F, 211F, 241F, 301F FIYHNGE305A Hinged Filter/Evap. And Comp./Control Access Door TCH/YCH 181F, 211F, 241F, 301F Frostat FIYLOAM023A Frostat TC/YCD151,181,241 with H,J,K,L in 10th digit w/FIYABRD002B High Efficiency Motors Can be used on downflow or horizontal units unless specified on matrix sheets. FIYHEMT001A 2 HP High Effic. Motor (86.5 Eff.)(208-230/460/60/3) FIYHEMT002A 2 HP High Effic. Motor (86.5 Eff.)(575/60/3) FIYHEMT003A 3 HP High Effic. Motor (89.5 Eff.)(208-230/60/3) FIYHEMT004A 3 HP High Effic. Motor (89.5 Eff.)(460/60/3) FIYHEMT005A 3 HP High Effic. Motor (89.5 Eff.)(575/60/3) FIYHEMT006A 5 HP High Effic. Motor (91.0 Eff.)(208-230/60/3) FIYHEMT007A 5 HP High Effic. Motor (91.0 Eff.)(460/60/3) FIYHEMT008A 5 HP High Effic. Motor (91.0 Eff.)(575/60/3) FIYHEMT009A 7½ HP High Effic. Motor (90.2 Eff.)(208-230/60/3) FIYHEMT010A 7½ HP High Effic. Motor (90.2 Eff.)(460/60/3) FIYHEMT011A 7½ HP High Effic. Motor (90.2 Eff.)(575/60/3) FIOPS-4 Effective 7/1/12 14-1011-28 Downflow/Horizontal Packaged Cooling, Packaged Gas/Electric/Packaged Heat Pump Factory Installed Options (FIOPS) Table FIOPS-5-A — Accessories Model Number Description Used With ReliaTelTM Options Module FIYABRD002B is required when ordering the following accessories: Clogged Filter Switch (FIYDFPS005A/BAYDFPS005A), Fan Fail Switch (FIYDFPS006A/BAYDFPS006A), Discharge Air Sensing Kit (FIYTUBE008A,FIYTUBE009A, BAYTUBE008A, BAYTUBE009A), Frostat (FIYLOAM023A, BAYLOAM023A), Ventilation Override (must order BAYVNOR002B), Smoke Detector (FIYSMDT). FIYABRD002BReliaTel™ Options Module All Packaged Rooftop Units 12½-25 Tons Smoke Detector (Return Air) for downflow units with economizer FIYSMDT221A Return Air Smoke Detector Y/TCD150F FIYSMDT223A Return Air Smoke Detector Y/TCD151F-301F Smoke Detector (Return Air) for downflow units without economizer FIYSMDT222A Return Air Smoke Detector Y/TCD150F FIYSMDT224A Return Air Smoke Detector Y/TCD151F-301F Smoke Detector (Supply Air) FIYSMDT225A Supply and Return Smoke Detector Y/TCD150F FIYSMDT228A Supply and Return Smoke Detector Y/TCD151F-301F FIYSMDT301A Supply and Return Smoke Detector Y/TCH150F FIYSMDT303A Supply and Return Smoke Detector Y/TCH151F-301F Smoke Detector (Supply & Return Air) for downflow units with economizer FIYSMDT226A Supply and Return Smoke Detector Y/TCD150F FIYSMDT229A Supply and Return Smoke Detector Y/TCD151F-301F Smoke Detector (Supply & Return Air) for units with economizer FIYSMDT227A Supply and Return Smoke Detector Y/TCD150F FIYSMDT230A Supply and Return Smoke Detector Y/TCD151F-301F FIYSMDT302A Supply and Return Smoke Detector Y/TCH150F FIYSMDT304A Supply and Return Smoke Detector Y/TCH151F-301F 1The return air smoke detector may not fit up or work properly on the Voyager Units 12½-25 Tons when used in conjunction with 3rd party accessories (such as bolt on heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory. 2Smoke Detectors available for downflow units only. 3Functional only with ReliaTel™ Options Module (FIYABR002B). Stainless Steel Heat Exchanger FIYSSHX001A 150 MBH Stainless Steel Heat Exchanger FIYSSHX002A 250 MBH Stainless Steel Heat Exchanger FIYSSHX003A 350 MBH Stainless Steel Heat Exchanger FIYSSHX004A 400 MBH Stainless Steel Heat Exchanger Switches1 FIYDFPS005A Clogged Filter Switch FIYDFPS006A Fan Failure Switch YC*150,151 Low Heat YC*150,151 High Heat YC*155,175,180,181,200,210,211,240,241,250,300 and 301 Low Heat YC*155,175,180,181,210,211 High Heat YC*200,240,241,250,300,301 High Heat All Packaged Rooftop Units 12½-25 Tons All Packaged Rooftop Units 12½-25 Tons 1 Functional only with ReliaTel™ Options Module (FIYABR002B). FIOPS-5 Effective 7/1/12 14-1011-28 Downflow/Horizontal Packaged Cooling, Packaged Gas/Electric/Packaged Heat Pump Factory Installed Options (FIOPS) Table FIOPS-6-A — Accessories Model Number Description Used With Through the Base Electrical Must be used with Unit Mounted Disconnect Switch or Unit Mounted Circuit Breaker. When adding heat, must order Trane Electric Heat. If no factory installed Unit Mounted disconnect Switch or Unit Mounted Circuit Breaker is required, order the Through the Base Utility Access Option (FIYTBUA****) FIYTBUE206A Through-the-Base Electrical Option FIYTBUE207A Through-the-Base Electrical Option FIYTBUE208A Through-the-Base Electrical Option FIYTBUE209A Through-the-Base Electrical Option FIYTBUE210A Through-the-Base Electrical Option FIYTBUE211A Through-the-Base Electrical Option FIYTBUE212A Through-the-Base Electrical Option FIYTBUE213A Through-the-Base Electrical Option FIYTBUE214A Through-the-Base Electrical Option FIYTBUE215A Through-the-Base Electrical Option FIYTBUE216A Through-the-Base Electrical Option FIYTBUE300A Through-the-Base Electrical Option FIYTBUE301A Through-the-Base Electrical Option FIYTBUE302A Through-the-Base Electrical Option FIYTBUE303A Through-the-Base Electrical Option FIYTBUE304A Through-the-Base Electrical Option FIYTBUE305A Through-the-Base Electrical Option FIYTBUE306A Through-the-Base Electrical Option FIYTBUE307A Through-the-Base Electrical Option FIYTBUE308A Through-the-Base Electrical Option FIYTBUE309A Through-the-Base Electrical Option FIYTBUE310A Through-the-Base Electrical Option Through The Base Gas Piping FIYTBUG202A1 Through-the-Base Gas Piping YCD150,151 Low & High Heat, YCD180-301 Low Heat FIYTBUG203A1 Through-the-Base Gas Piping YCD180-301 High Heat FIYTBUG205A2 Through-the-Base Gas Piping YCD150,151 Low & High Heat, YCD180-301 Low Heat FIYTBUG206A2 Through-the-Base Gas Piping YCD180-301 High Heat 1 Must order when ordering through-the-base electrical or through-the-base access option (downflow only). 2 Order when not ordering through-the-base electrical or through-the-base access option (downflow only). Through the Base Utilities Access Order this accessory when no factory installed Unit Mounted Disconnect Switch or Unit Mounted Circuit Breaker is required. If factory installed Unit Mounted Disconnect or Unit Mounted Circuit Breaker is required, order the Through the Base Electrical Option (FIYTBUE****) from the FIOP Matrix page. FIYTBUA204A Through the Base Utilities Access YCD150,151,180,210 FIYTBUA205A Through the Base Utilities Access TCD150,151,180,210,WCD150,180 FIYTBUA206A Through the Base Utilities Access YCD181,211,240,241,300,301 FIYTBUA207A Through the Base Utilities Access TCD181,211,240,241,300,301,151,181E, WC*150,180E,WCD240,300 Tool-less Condenser Hail Guard FIYGARD003A Tool-less Condenser Hail Guard WC*150E, 180E FIYGARD006A Tool-less Condenser Hail Guard WC*240E FIYGARD102A Tool-less Condenser Hail Guard T/YC*150F FIYGARD103A Tool-less Condenser Hail Guard T/YC*151F, 180F ,210F ,240F ,300F FIYGARD106A Tool-less Condenser Hail Guard T/YC*181F, 211F, 241F, 301F 2" Pleated Filters (MERV 7) FIYPLTD001A 2" Pleated Filters (MERV 7) T/YC*150F FIYPLTD002A 2" Pleated Filters (MERV 7) T/YCD151F, 180F ,210F ,240F ,300F, WCD150E FIYPLTD003A 2" Pleated Filters (MERV 7) T/YCH151F, 180F ,210F ,240F ,300F, WCH150E FIYPLTD004A 2" Pleated Filters (MERV 7) T/YCD181F, 211F, 241F, 301F, WCD180E, WCD240E FIYPLTD005A 2" Pleated Filters (MERV 7) T/YCH181F, 211F, 241F, 301F, WCH180E, WCH240E 2" Pleated Filters (MERV 13) FIYPLTD131A 2" Pleated Filters (MERV 7) T/YC*150F FIYPLTD132A 2" Pleated Filters (MERV 7) T/YCD151F, 180F ,210F ,240F ,300F, WCD150E FIYPLTD133A 2" Pleated Filters (MERV 7) T/YCD181F, 211F, 241F, 301F, WCD180E, WCD240E FIYPLTD134A 2" Pleated Filters (MERV 7) T/YCH151F, 180F ,210F ,240F ,300F, WCH150E FIYPLTD135A 2" Pleated Filters (MERV 7) T/YCH181F, 211F, 241F, 301F, WCH180E, WCH240E Shaft Grounding Rings (Multi Speed Motors with FVD) FIYSHGR001A Shaft Grounding Ring For - 56HZ Frame Motors (W,T,Y)C*150-241F (StdSize Motor w/ VFD) (W,T,Y)C*150-181F (OS Motor w/ VFD) FIYSHGR002A Shaft Grounding Ring For - 184 Frame Motors (T,Y)C*300-301F (StdSize Motor w/ VFD) (W,T,Y)C*210-241F (OS Motor w/ VFD) FIOPS-6 Effective 7/1/12 14-1011-28 Indoor Gas Heating Products American Standard Heating & Air Conditioning now offers one of the most complete lines of indoor and outdoor gas heating products on the market today! Tubular Heat Exchanger Propeller Fan Unit Heater Model ATND/ATPD The American Standard Heating & Air Conditioning tubular heat exchanger is a durable unit heater that provides an alternative to the traditional clam shell style. These propeller style units combine the latest tubular heat exchanger technology with in-shot burner design to create an efficient operation unit. Table UH-1-A — Tubular Heat Exchanger Propeller Gas Unit Heater GTND/GTPD 003004006007009011012015017020025030035040 Input MBh 30 45 60 75 90 105120150175200250300350400 Output MBh 24.937.3549.861.573.886.198.4124.5 145.25 166.0 207.5 249.0 290.5 332.0 Thermal Efficiency 83%83%83%82%82%82%82%83%83%83%83%83%83%83% Free Air Delivery (cfm) 370 550 740 920 1100130014752400285032003450500056005800 Air Temperature Rise F6060606060606047464754454751 Full Load Amps at 120V3.03.04.14.16.46.46.45.88.08.08.011.3 13.5 13.5 Motor Data Hp 1/201/201/121/121/101/101/10 ¼ 1/3 1/3 1/3 ¼ 1/3 1/3 kW 0.040.040.060.060.075 0.075 0.0750.190.250.250.250.190.250.25 Type SPSPSPSPSPSPSPPSC PSC PSC PSC PSC PSC PSC Rpm 16501650105010501050105010501140114011401140114011401140 Amps at 155V 1.91.92.62.62.64.24.24.75.85.85.89.411.6 11.6 1 Ratings are shown for elevations up to 2,000 feet above sea level. Above 2,000 feet, input must be derated 4 percent for each 1,000 feet above sea level. 2CS= Capacitor Start, PSC = Permanent Split Capacitor. 3Standard motors are 115/60/1 open drip-proof. 40.2 maximum external static pressure. 5Unit amps are based on hot surface pilot ignition. High Efficiency Propeller Fan Gas Unit Heaters Model AHND/AHPD American Standard Heating & Air Conditioning high efficiency propeller fan gas unit heaters can achieve annual fuel savings of 20 to 25 percent or more over conventional gravity-vented heaters. Features include a factory installed flue vent fan and sealed flue collector that control combustion and excess air during the on-cycle. Heated air no longer escapes through the draft diverted opening during the off cycle. Energy-saving intermittent pilot ignition reduces gas losses. The pilot only operates when required. Horizontal power venting allows for side wall venting, smaller openings and single-walled vent pipe. These high efficiency gas fan unit heaters carry a ten-year non-prorated warranty on the heat exchanger, flue collector and burners. Table UH-1-B — High Efficiency Propeller Fan Gas Unit Heater ATND/ATPD 010012 015017 020 022025 030 035 040 Input MBh 100125 150175 200 225250 300 350 400 Output MBh 80100120140160180200240280320 Flue Outlet (1) 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" Rec. Flue Size 4"R4"R 4"R4"R 5"R 5"R5"R 6"R 6"R 6"R CFM 14801650 22002530 2640 27003100 4400 5000 5300 Air Temperature Rise °F 5056 5051 56 6160 50 52 56 Outlet Velocity 7759101045 10701010950980110011501050 Nominal Horsepower 1/20 1/10 1/4 1/3 1/3 1/3 1/3 (2) 1/4 (2) 1/3 (2) 1/3 Motor Amps 2.62.8 4.04.5 4.5 4.54.5 8.0 9.0 9.0 Thermal Efficiency 80%80% 80%80% 80% 80%80% 80% 80% 80% 1 All flue outlets are 5 1/8" O.D. ±1/32" (reducer by installer where required). Increaser supplied by manufacturer for 030,035,040 sizes. Contact your American Standard Heating & Air Conditioning Territory Manager for more information. UH-1 Effective 7/1/12 14-1011-28 Indoor Gas Heating Products High Efficiency Centrifugal Fan Gas Unit Heaters Model ABND/ABPD The American Standard Heating & Air Conditioning high efficiency centrifugal fan gas unit heater incorporates the same features as the high efficiency propeller unit heater. An exceptionally balanced centrifugal blower assembly results in quieter operation. The high efficiency centrifugal fan is also well-suited for high static applications where ductwork is required. Duct discharge flanges may be ordered in lieu of horizontal louvers to accommodate ductwork. American Standard Heating & Air Conditioning's high efficiency centrifugal fan gas unit heater carries a ten-year non-prorated warranty on the heat exchanger, flue collector and burners. Table UH-2-A — High Efficiency Centrifugal Fan Gas Unit Heater ABND/ABPD Input MBh Output MBh Flue Outlet (1) Flue Outlet Free Air Delivery Outlet Velocity Nominal Horsepower Motor Amps 010012 015017020 022025030035040 100125 150175200 225250300350400 80 100 120140160 180200240280320 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 4"R4"R 4"R4"R5"R 5"R5"R6"R6"R6"R 12001575 197523002400 26002850395046004800 8809501030 1045965 9359301080 1090 1000 1/41/3 1/21/23/4 3/43/43/4 1 1 5.1 6.6 7.4 7.4 12.0 12.012.012.015.415.4 1 All flue outlets are 5 1/8" O.D. ±1/32" (reducer by installer where required). Increaser supplied by manufacturer for 030,035,040 sizes. High Efficiency Indoor Gas Duct Furnace Model ALND/ALPD The American Standard Heating & Air Conditioning high efficiency indoor gas duct furnaces can achieve annual fuel savings of 20 to 25 percent or more over conventional gravity vented units. Features include a factory installed flue vent fan and sealed flue collector that control combustion and excess air during the on-cycle. Heated air no longer escapes through the draft diverted opening during the off cycle. Energy saving intermittent pilot ignition reduces gas losses. The pilot operates only when required. Horizontal power venting allows side wall venting, smaller openings and single wall vent pipe. Table UH-2-B — High Efficiency Indoor Gas Duct Furnace ALND/ALPD 010012 015017020 022025030035040 Input MBh 100125 150175200 225250300350400 Output MBh 80 100 120140160 180200240280320 Max CFM 24693086 370443214938 55566173740786429877 Pressure Drop 0.900.80 0.750.750.75 0.750.800.900.900.90 Min. Temperature Rise °F3030 303030 3030303030 Min. CFM 929 1157 138916201852 20832315277832413704 Pressure Drop 0.120.13 0.150.140.14 0.140.140.130.130.14 Max Temperature Rise °F8080 808080 8080808080 Flue Outlet (1) 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" 5 1/8" Rec. Flue Size 4"R4"R 4"R4"R5"R 5"R5"R6"R6"R6"R 1 All flue outlets are 5 1/8" O.D. ±1/32" (reducer by installer where required). Increaser supplied by manufacturer for 030,035,040 sizes. Contact your American Standard Heating & Air Conditioning Territory Manager for more information. UH-2 Effective 7/1/12 14-1011-28 Indoor Gas Heating Products Separated Combustion Propeller Fan Unit Heaters Model AAND/AAPD The American Standard Heating & Air Conditioning separated combustion propeller type unit heater keeps energy costs down by offering 80 percent thermal efficiencies. With model inputs available from 100 through 400 MBH, they are designed to be installed in mildly hostile environments where dusty, dirty and mildly corrosives exist or high humidity or slightly negative pressures prevail. The American Standard Heating & Air Conditioning propeller unit separates the combustion process from the environment where the unit is installed. A power venting system draws a controlled quantity of combustion air from outside the building. The same system exhausts flue gas products to the outside. The burners, pilot and flue system are enclosed within the unit. The entire combustion process is literally unaffected by the atmosphere in the space where the unit is located. Combustion and exhaust air may be piped horizontally through a side wall, or vertically through the roof via our standard two-pipe venting arrangement or optional concentric vent kit which utilizes one 8-inch side wall or rooftop penetration for both the combustion and exhaust air. Both venting systems are C.S.A. International certified. Table UH-3-A — Separated Combustion Propeller Fan Gas Unit Heater AAND/AAPD 010012015017020022025030035040 Input MBh100125150175200225250300350400 kW 29.336.643.951.258.665.973.287.8102.5 117.1 Output MBh 80 100120140160180200240280320 kW 23.429.335.141.046.952.758.670.382.093.7 Thermal Efficiency 80%80%80%80%80%80%80%80%80%80% Free Air Delivery cfm 1480165022002530264027003100440050005300 m3/s 0.6990.7791.0381.1941.2461.2741.4632.0772.3602.502 Air Temperature Rise°F 50565051566160505256 °C 28312828313433282931 Output Velocity fpm 775 910 104510701000 950 980 110011501050 m/s 3.94.65.35.45.14.85.05.65.85.3 Full Load Amps at 115V 5.86.07.27.87.87.88.811.2 12.2 12.2 Motor Data hp 1/20 1/10 1/4 1/3 1/3 1/3 1/2 (2) 1/4 (2) 1/3 (2) 1/3 kW 0.0370.0750.1860.2490.2490.2490.373 (2) 0.186 (2) 0.249 (2) 0.249 Type SP SP PSCPSCPSCPSCPSCPSCPSCPSC rpm 1,0501,0501,1401,1401,1401,1401,1401,1401,1401,140 Amps at 115V 2.62.84.04.54.54.55.58.09.09.0 Notes: 1Ratings are shown for elevations up to 2,000 feet above sea level. Above 2,000 feet, input must be derated 4 percent for each 1,000 feet above sea level. 2Standard motor is 115/60/1 open drip-proof. 3SP = Shaded Pole; PSC = Permanent Split Capacitor. Contact your American Standard Heating & Air Conditioning Territory Manager for more information. UH-3 Effective 7/1/12 14-1011-28 Indoor Gas Heating Products Separated Combustion Centrifugal Fan Unit Heaters Model AKND/AKPD The American Standard Heating & Air Conditioning separated combustion centrifugal type unit heater keeps energy costs down by offering 80 percent thermal efficiencies. With model inputs available from 100 through 400 MBh, they are designed to be installed in mildly hostile environments where dusty, dirty and mildly corrosives exist or high humidity or slightly negative pressures prevail. This unit operates at a static pressure up to 0.2” water column, and is available with a louvered (standard) or flanged outlet (optional) when discharge duct work is desired. These units separate the combustion process from the environment where the unit is installed. A power venting system draws a controlled quantity of combustion air from outside the building. The same system exhausts flue gas products to the outside. The burners, pilot and flue system are enclosed within the unit. The entire combustion process is literally unaffected by the atmosphere in the space where the unit is located. Table UH-4-A — Separated Combustion Centrifugal Fan Gas Unit Heater AKND/AKPD 010012015017020022025030035040 Input MBh100125150175200225250300350400 kW 29.336.643.951.258.665.973.287.8102.5 117.1 Output MBh 80 100120140160180200240280320 kW 23.429.335.141.046.952.758.670.382.093.7 Thermal Efficiency 80%80%80%80%80%80%80%80%80%80% Free Air Delivery cfm 1,2001,5751,9752,3002,4002,6002,8503,9504,6004,800 m3/s 0.5660.7430.9321.0861.1331.2271.3451.8642.1712.266 Air Temperature Rise°F 62595656626465565662 °C 34333131343636313134 Output Velocity fpm 880 95010301045965 935 930108010901000 m/s 4.474.835.235.314.904.754.725.495.545.08 Full Load Amps at 115V 8.3 9.8 10.610.615.215.215.215.218.618.6 Motor Data hp 1/41/31/21/23/43/43/43/4 1 1 kW 0.190.250.370.370.560.560.560.560.750.75 TypeSPHSPHSPHSPHSPHSPHSPHSPH CS CS rpm 1725172517251725172517251725172517251725 Amps at 115V 5.1 6.6 7.4 7.4 12.012.012.012.015.415.4 Notes: 1Ratings are shown for elevations up to 2,000 feet above sea level. Above 2,000 feet, input must be derated 4 percent for each 1,000 feet above sea level. 2Standard motor is 115/60/1 open drip-proof. 3SPH = Split Phase; CS = Capacitor Start. Contact your American Standard Heating & Air Conditioning Territory Manager for more information. UH-4 Effective 7/1/12 14-1011-28 Indoor Gas Heating Products Separated Combustion Duct Furnace Model AMND/AMPD The American Standard Heating & Air Conditioning separated combustion duct furnace is designed for installation in dusty, dirty or mildly corrosive environments or where high humidity or slightly negative pressures exist. Ideal applications include HVAC equipment rooms, manufacturing facilities, automotive garages and greenhouses. Table UH-5-A — Separated Combustion Centrifugal Fan Gas Unit Heater AMND/AMPD 010012015017020022025030035040 Input Max MBh100125150175200225250300350400 kW 29.336.643.951.258.665.973.287.8102.5 117.1 Input Min MBh5062.57587.5100 112.5 125150175200 kW 14.618.322.025.629.332.936.643.951.258.6 Output MBh 80 100120140160180200240280320 kW 23.429.335.141.046.952.758.670.382.093.7 Min cfm 822 102812331439164518502056246728783289 m3/s 0.3880.4850.5820.6790.7760.8730.9701.1641.3581.552 Air Temperature Rise°F 90909090909090909090 °C 50505050505050505050 P.D. in. of H2O 0.100.090.090.090.090.090.090.100.100.10 kPa 0.020.020.020.020.020.020.020.020.020.02 Max cfm 370046255550647574018326925111101 12951 14801 m3/s 1.7462.1832.6203.0563.4933.9304.3665.2406.1136.986 Air Temperature Rise°F 20202020202020202020 °C 11111111111111111111 P.D. in. of H2O 2.031.921.811.861.901.931.962.002.022.05 kPa 0.510.480.450.460.470.480.490.500.500.51 Note: 1Ratings are shown for elevations up to 2,000 feet above sea level. Above 2,000 feet input must be derated four percent for each 1,000 feet above sea level. Contact your American Standard Heating & Air Conditioning Territory Manager for more information. UH-5 Effective 7/1/12 14-1011-28 Standard Trane Warranty Company A “Manufacturer Backed” Extended Warranty Program Dealer Opportunity • Limits dealer labor obligation • Reduces warranty reserve needed during first year of dealer labor obligation • Secures future service business • Develops long term relationship between the dealer and the equipment owner • Strengthens opportunity for maintenance agreement • Regular maintenance extends equipment life expectancy • Contract terms and conditions requires regular maintenance • Reduces customer complaints • In the unlikely event of a failure the customer does not receive an invoice. Standard Trane Warranty Company pays the dealer directly for covered repairs. • Income potential • Dealer mark up applies to the sale of the extended warranty contract to the equipment owner • Generous pay out on claims submitted using extended warranty task times and program details • Rapid payment terms on claims • 7 day payment from process date • Pre-authorizations • The only time a pre-authorization is required is for the repair/replace option • Standard Trane Warranty Company trusts the dealer expert Homeowner Solution • Peace of mind • Manufacturer backed • Standard Trane Warranty Company is the obligor to the equipment owner • No out-of-pocket expenses for covered repairs • Known servicer • The equipment owner knows who to call • Quick resolution if a problem arises • Quality Service • Service by an American Standard dealer • Trained service technicians • Direct access to manufacturer • Transferable • Within 90 days of the property closing date To contact Standard Trane Warranty Company • Email: [email protected] • Phone: 1-800-554-8005 • Office hours are 8:00 AM to 5:00 PM CST, Monday through Friday except for holidays Please check www.asdealernet.com for all the latest and up to date information on warranty models available, task times, program details, confirmation of coverage, forms and more. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. WA-1 Effective 7/1/12 14-1011-28 Roof Curbs Baycurb050A FULL PERIMETER Roof Mounting Curb OUtline 018 through 036 Full Perimeter BAYCURB050A 4TCY4024-036 4TCX3018-036/4TCC3018-036 4WCZ6036/4DCZ6036 4WCY4024-036/4DCY4024-036 2/4WCX3018-036/2/4WCC3018-036 4YCZ6036 4YCY4024-036 2/4YCX3018-036/2/4YCC3018-036 Full Perimeter BAYCURB051A 4TCY4042-060 4TCX3042-060/4TCC3042-060 4WCZ6048-060/4DCZ6048-060 4WCY4042-060/4DCY4042-060 2/4WCX3042-060/2/4WCC3042-060 4YCZ6048-060 4YCY4042-060 2/4YCX3042-060/2/4YCC3042-060 Baycurb051A FULL PERIMETER Roof Mounting Curb OUtline 15 7/8 56 1/8 3 1 1/2 19 1/2 20 10 7/8 4 3/4 19 1/2 41 7/8 14 042 through 060 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AC/IN-1 Effective 7/1/12 14-1011-28 3-25 Ton Packaged Units Roof Curb Compatibility Information Table AC/IN-2-A — 3-10 Ton Convertible Packaged Units Roof Curb Compatibility BAYCURB042 T/YSC 036A 048A 060A 036E 048E 060E BAYCURB043 T/YHC 033A 036A 043A 048A 060A 063A 036E WSC 036A 048A 060A 036E 048E T/YSC 072A 090A 092A 102A 120A 072E 090E 092E 102E 120E BAYCURB044 T/YHC 072A 092A 102A 120A 048E 060E 072E 092E* 102E* 120E* WSC 072A 090A 120A 060E 072E 090E T/YSC T/YHC 092E 102E 120E WSC 120E * = This curb is used for retrofit or replacement applications only for these units. Table AC/IN-2-B — 12½-25 Ton Packaged Units Roof Curb Compatibility Reference for Packaged Units Manufactured Prior to 2002 BAYCURB021A/B YCD 036A 036C 037C 048A 048C 049C 060A 060C TCD 036C 037C 048C 049C 060C WCD 036C 048C 060C BAYCURB022A/B YCD 061C 074C 075A 075B 075C 086C 090A 090B 090C 090D 091D 102C TCD 061C 074C 075A 075B 075C 086C 090A 090B 090C 090D 091C 091D 120C 102C 120C WCD 075A 075C 090A 090C BAYCURB025A/B YCD 102A 102B 103B 103C 120A 120B 121B 150C TCD 102A 102B 103B 103C 120A 120B 121B 150C WCD 120A 120B BAYCURB026A/B YCD 121C 150A 150B 150D 151B 151C 180A 180B 210C 150E TCD 121C 150A 150B 150D 151B 151C 180A 180B 210C 150E WCD 150A 150B 180A 180B BAYCURB027A/B YCD 181B 181C 210A 210B 211B 211C 240A 240B 241B 241C 300B 301C TCD 181B 181C 210A 210B 211B 211C 240A 240B 241B 241C 300B 301C 180E 210E 211E 240E 241E 300E 151E 181E 301E 180E 210E 211E 240E 241E 300E 151E 181E 301E WCD 240A 240B 150E 180E 240E General Notes: 1If ordering Thru-The-Base options, the curb must be an April 1994 to present model curb to allow Thru-The-Base connections. The older curb models do not allow for these connections. The units will still fit the curb, but the Thru-The-Base connections will not be available. 2TCD036A, TCD048A, TCD060A, WCD036A, WCD048A, WCD060A are not 12½-25 Ton units. These units were manufactured in Ft.Smith, AR and will not fit any 12½-25 Ton curbs. 3All horizontal 3-7½ ton, all horizontal 102C, and all horizontal 120C units will fit the downflow curbs, but BAYINSL101A kit must be installed across the bottom of the evaporator section of the unit to prevent condensate leakage into the space. 4If another manufacturers curb was used initially, the adapter curb may not fit. Table AC/IN-2-C — Convertible 3-10 Ton Curb Adapters Model NumberDescription BAYQACB009A BAYQACB010A BAYQACB011A BAYQACB012A BAYQACB013A BAYQACB044A BAYQACB500A BAYQACB501A BAYQACB502A Quick Adapt Roof Curb Converts BAYCURB021 to Convertible 3 - 5 Ton Quick Adapt Roof Curb Converts BAYCURB022 to Convertible 3 - 5 Ton Quick Adapt Roof Curb Converts BAYCURB022 to Convertible 6 - 10 Ton Quick Adapt Roof Curb Converts BAYCURB025 to Convertible 6 - 10 Ton Quick Adapt Roof Curb Converts BAYCURB026 to Convertible 6 - 10 Ton Quick Adapt Roof Curb Converts BAYCURB026 to BAYCURB027 Quick Adapt Roof Curb Converts CRRFCURB001A01 to BAYCURB042A Quick Adapt Roof Curb Converts CRRFCURB001A01 to BAYCURB043A Quick Adapt Roof Curb Converts CRRFCURB001A03 to BAYCURB043A Note: If another manufacturers curb was used initially, the adapter curb may not fit For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AC/IN-2 Effective 7/1/12 14-1011-28 Thermal Expansion Valves Table AC/IN-3-A Cooling/Heat Pump Non-Bleed TXV Kits- Dual Direction Flow-TXA/C-BC Coils R-410 Model Number Expansion Valve TXV Cooling/Heat Pump Kit R-22 Model Numbers Used With 13 SEER Coils 4AYTXVH3D1831A2AYTXVH3C1818A2/4TXC,TXA018 4AYTXVH3D1831A2AYTXVH3C2425A2/4TXC,TXA024,025 4AYTXVH3D1831A2AYTXVH3C3031A2/4TXC,TXA031 4AYTXVH3D3343A— 4TXC,4TXA-032 4AYTXVH3D3343A2AYTXVH3C3337A2/4TXC,TXA036,037 4AYTXVH3D3343A2AYTXVH3C4243A2/4TXC,TXA042,043 4AYTXVH3D4863A— 4TXC,4TXA-044 4AYTXVH3D4863A2AYTXVH3C4850A2/4TXC,TXA048,049,050 4AYTXVH3D4863A2AYTXVH3C5463A2/4TXC,TXA060,061,064 Table AC/IN-3-B Cooling/Heat Pump Non-Bleed TXV Kits- Dual Direction Flow General Information This Thermostatic Expansion Valve Kit may be used on any indoor air handler or coil that is equipped with a current thermostatic expansion valve with an internal check valve and mechanical fittings This kit can be used on split system heat pumps and air conditioning systems. Thermostatic Expansion Valve Kits can be field installed to fit a variety of sizes and combinations of air handlers or coils and outdoor units to optimize performance. This TXV kit will normally be used when a different refrigerant is going to be used in the air handler or coil than what is indicated on the unit name plate. The TXV type must always match the refrigerant type used in the outdoor unit. Kit Identification The first character in the kit model number indicates the type of refrigerant that the valve can be used with. Example a 2AYTXVH3D1830A is an R-22 valve. The “3” in the eighth digit in the model number identifies the valve as a non-bleed TXV. When this TXV kit is installed with an outdoor unit that contains a reciprocating compressor, the outdoor unit must be equipped with a hard start kit if not factory installed. If the outdoor unit contains a scroll compressor, the installation of a hard start kit may be required. Inspection Check carefully for any shipping damage. Any such damage must be reported and claims made against the transportation company immediately. Any missing parts should be reported to your supplier at once and replaced with authorized parts only. R-410 Model Number R-22 Model Number Used With Horizontal Flat Coils 4AYTXVH3D1831A2AYTXVH3C1818A 2/4TXF-018 4AYTXVH3D3343A2AYTXVH3C3337A 2/4TXF-033 4AYTXVH3D3343A2AYTXVH3C4243A 2/4TXF-041 4AYTXVH3D4863A2AYTXVH3C5463A 2/4TXF-054 4AYTXVH3D4863A2AYTXVH3C5463A 2/4TXF-063 Table AC/IN-3-C Cooling/Heat Pump Non-Bleed TXV Kits- Dual Direction Flow-TXA/C-AS Coils R-410R-22 Model Model Used With AS Number Number Aluminum Coils 4AYTXVH3B2531A2AYTXVH3B2531A 2/4TXA,TXC-025 4AYTXVH3B2531A2AYTXVH3B2531A 2/4TXA,TXC-031 4AYTXVH3B3654A2AYTXVH3B3637A 2/4TXA,TXC-036 4AYTXVH3B3654A2AYTXVH3B3637A 2/4TXA,TXC-037 4AYTXVH3B3654A2AYTXVH3B5454A 2/4TXA,TXC-054 4AYTXVH3B6165A2AYTXVH3B6565A 2/4TXA,TXC-065 Table AC/IN-3-D Cooling/Heat Pump Non-Bleed TXV Kits- Dual Direction Flow R-410 Number R-22 Numbers Used With Air Handlers 4AYTXVH3D1830A2AYTXVH3D1830A 4AYTXVH3D1831A2AYTXVH3D1830A 4AYTXVH3D1831A2AYTXVH3D1830A 4AYTXVH3D1831A2AYTXVH3D1830A — 2AYTXVH3D3636A 4AYTXVH3D3642A— — 2AYTXVH3D4260A 4AYTXVH3D4863A— 2TFB-018-030 2TFB-036 2/4TFE-025 4AYTXVH3D1831A2AYTXVH3D1830A — 2AYTXVH3D3636A 4AYTXVH3D3642A— — 2AYTXVH3D4260A 4AYTXVH3D4863A— 4AYTXVH3D1800A2AYTXVH3D1830A 4AYTXVH3D1830A2AYTXVH3D1830A 4AYTXVH3D1831A2AYTXVH3D1830A 4AYTXVH3D3600A2AYTXVH3D1830A 4AYTXVH3D3343A2AYTXVH3D4260A 4AYTXVH3D4863A2AYTXVH3D4260A 2/4TEH-018-030 4TEH-036 2TEH-036-042 4TEH-042-060 2TEH-048-060 4AYTXVH3D3642A2AYTXVH3D4260A 4AYTXVH3D4863A2AYTXVH3D4260A 2/4TEE-039 2/4TEE-048-064 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AC/IN-3 2/4TEC-018-030 2/4TEC-036 2/4TEC-036-042 2/4TEC-042-060 2/4TEC-048-060 2/4TGB-018 2/4TGB-025 2/4TGB-030 2/4TGB-036 2/4TGB-042 2/4TGB-048 Effective 7/1/12 14-1011-28 Thermal Expansion Valves Table AC/IN-4-A — Cooling Bleed TXV Kits – Single Direction Flow Model Used With Number AC Units Liquid Line Connection Dia. I.D. (In.) TAYTXVA0B5C1-1½ Ton TAYTXVA0C5C2-2½ Ton TAYTXVA0E5C3-3½ Ton TAYTXVA0G5C4 Ton TAYTXVA0H5C 5-6 Ton Expansion Valve TXV Cooling Kit /4 5 /16 3 /8 3 /8 3 /8 1 Gas Line Connection Shipping Dia. I.D. (In.) Weight (Ibs.) /8 3 /4 7 /8 11/8 11/8 5 Refrigerant 2R-22 2R-22 2R-22 2R-22 2R-22 Table AC/IN-4-B — Cooling Non-Bleed TXV Kits – Single Direction Flow Model Used With Number AC Units Liquid Line Connection Dia. I.D. (In.) TAYTXVA0B3C1-1½ Ton TAYTXVA0C3C2-2½ Ton TAYTXVA0E3C3-3½ Ton TAYTXVA0G3C4 Ton TAYTXVA0H3C 5-6 Ton /4 5 /16 3 /8 3 /8 3 /8 1 Gas Line Connection Shipping Dia. I.D. (In.) Weight (Ibs.) /8 3 /4 7 /8 1 1 /8 11/8 5 Refrigerant 2R-22 2R-22 2R-22 2R-22 2R-22 Table AC/IN-4-C — Heat Pump Non- Bleed TXV Kits (also for cooling) – Dual Direction Flow Model Used With Number AC Units Liquid Line Connection Dia. I.D. (In.) TAYTXVH0B3C1-1½ Ton TAYTXVH0C3C2-2½ Ton TAYTXVH0E3C3-3½ Ton TAYTXVH0G3C4 Ton TAYTXVH0H3C 5-6 Ton Expansion Valve TXV Heat Pump Kit* /4 5 /16 3 /8 3 /8 3 /8 1 Gas Line Connection Shipping Dia. I.D. (In.) Weight (Ibs.) /8 3 /4 7 /8 11/8 1 1 /8 5 Refrigerant 3R-22 3R-22 3R-22 3R-22 3R-22 Table AC/IN-4-D— Cooling/Heat Pump Non-Bleed TXV Kits - Dual Direction Flow* Model Used With Number AC Units Liquid Line Connection Dia. I.D. (In.) TAYTXVH0D3C2½ -3 Ton TAYTXVH0G3C 4-5 Ton Gas Line Connection Shipping Dia. I.D. (In.) Weight (Ibs.) Refrigerant /811/8 2R-22 3 /811/8 2R-22 3 Table AC/IN-4-E— R-410A Heat Pump Non-Bleed TXV Kits (also for cooling) - Dual direction flow Model Used With Number HP/AC Units 4AYTXVH3A1830A1½-2½ Ton 4AYTXVH3A3654A 3-4 Ton 4AYTXVH3A6060A 5 Ton Liquid Line Connection Dia. I.D. (In.) 5 /161 3 /8 3 /8 Gas Line Connection Shipping Dia. I.D. (In.) Weight (Ibs.) /42 7 /83 7 /8 3 Refrigerant 2 R-410A 2R-410A 2R-410A 1 1 1/2 ton requires 1/4" liquid line; reducer fittings provided. 2 1 1/2 ton requires 1/2 " suction line, 2 ton requires 5/8; reducer fittings provided. 3 3 & 3 1/2 ton requires 3/4" suction line; reducer fitting provided. * Used with TXH coils only where approved for use with 2 compressor systems. Notes: • Use in place of FCCV (Above) on air handlers and coils • Match TXV kit size to outdoor nominal cooling capacity • Braze field connections For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AC/IN-4 Effective 7/1/12 14-1011-28 Equipment Date Identification 1980 – 2009 The nine digit serial numbers on all American Standard central air conditioning and heating products are employed to identify the year and fiscal week of product manufacture. Year of manufacture.............................First digit..................................... M124X04CF Fiscal week of manufacture..................Second and third digit................ M124X04CF Day of week of manufacture.................Fourth digit................................. M124X04CF Consecutive order of production..........Last Five digits........................... M124X04CF Exception – Accessories are an exception to the nine digit serial number assignment and may have only three digits to indicate date code. Coils which have only three digits to indicate date code are an exception to the nine digit serial number assignment. Year Residential, ID & OD1 Light Commercial Products & Compressors Ducane Oil1 Horizontal Gas Furnaces2 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 O, A T U W X Y S B C D E F G H J L M N 9 Q 85 86 87 88 89 90 91 92 93 94 Year Residential, ID & OD1 Light Commercial Products & Compressors Ducane Oil1 Horizontal Gas Furnaces2 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 K K M N P R Z 2 3 4 5 6 7 8 9 95 96 97 98 99 — — — — — — — — — — 1 Beginning with 1/1/96 (L01) Ducane oil furnace production uses same date code method as gas furnace. Prior to 1/1/96 Ducane serial number used last four digits = date code, example HA1234569540 1995, 40th week. Example: 123456-8 5 4 0 Year of manufacture Fiscal week of manufacture 2 Dedicated horizontal gas furnaces, production ceased after introduction of convertible furnaces. 2010 Digit Description Current Digit Value Options 1 through 9 and blank space, Blank Space used when 0 (zero) 3 4TH 5TH Second to Last integer of the current calendar year Last integer of the current calendar year Fiscal Week (Tens numeral) Fiscal Week (Units numeral) Day of the Week 6TH Time Stamp 7TH Time Stamp 8TH Time Stamp 9TH Assembly Line Designator 1ST 2ND RD 10 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. TH Plant Code AC/IN-5 0 through 9 0 through 5 0 through 9 1 through 7 A through Z and 0 through 9, excluding I, O, Q, V, Y, and Z A through Z and 0 through 9, excluding I, O, Q, V, Y, and Z A through Z and 0 through 9, excluding I, O, Q, V, Y, and Z A through Z and 0 through 9, excluding I, O, Q, V, Y, and Z A, D, F, G, H, V, Y, X Effective 7/1/12 14-1011-28 Refrigerant Line Sets Table AC/IN-6-A — Refrigerant Line Sets ModelGas Line12 Number Dia. O.D. TAYREFLN325 TAYREFLN330 TAYREFLN340 TAYREFLN350 TAYREFLN725 TAYREFLN730 TAYREFLN740 TAYREFLN750 TAYREFLN950 /8 /8 7 /8 7 /8 3 /4 3 /4 3 /4 3 /4 5 /8 Liquid Line Dia. O.D. Length /8 25 /8 30 3 /8 40 3 /8 50 3 /8 25 3 /8 30 3 /8 40 3 /8 50 3 /8 50 7 3 7 3 Shipping Weight 20 24 30 39 19 22 28 35 30 1 Gas line 90o bend one end. 2 Gas line insulation 1/2" thickness. Note: Contains a holding charge of Nitrogen. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AC/IN-6 Effective 7/1/12 14-1011-28 Refrigerant HFC 410A (R-410A) Tables contain no allowances for vertical lift! Table AC/IN-7-A — Liquid Line Selection Table for R-410A Single Speed Systems Maximum Allowable Liquid Line Pressure Drop ....................................................................................................... = 50 PSI Subtract .43 PSI for each foot of Liquid Lift (if any).......................................................................................................... Do Not Exceed this value when selecting Liquid Line..................................................................................................... Pressure Drop (PSI) For Total Equivalent Length Tube Rated O.D. BTUH 20'40'60'80'100' 120' 140'160' 180'200' 220' 240' 1/4"150004.5 9.0 13.618.122.6 27.131.6 36.2 40.745.249.7 — 18000 6.3 12.6 18.8 25.1 31.4 37.7 44.0 — — — — — 24000 15.4 30.8 46.2 ———— — ——— — 15000 1.22.4 3.54.75.9 7.18.3 9.410.611.8 13.014.2 18000 1.63.3 4.96.68.29.8 11.513.114.8 16.4 18.019.7 5/16"240002.8 5.5 8.3 11.013.816.619.3 22.1 24.827.630.4 33.1 300004.1 8.3 12.416.620.724.829.0 33.1 37.341.445.5 49.7 360005.8 11.6 17.323.128.934.740.5 46.2 — — — — 420007.715.4 23.030.738.446.1— — — — — — 24000 1.01.9 2.93.84.85.86.7 7.7 8.69.610.611.5 30000 1.42.9 4.35.8 7.28.6 10.111.513.0 14.4 15.817.3 3/8" 36000 2.04.0 6.18.110.1 12.1 14.116.218.2 20.2 22.224.2 420002.7 5.3 8.010.613.316.018.6 21.3 23.926.629.3 31.9 480003.4 6.810.213.617.020.423.8 27.230.634.037.440.8 600005.110.3 15.420.625.730.836.0 41.1 46.3— — — 42000.51.1 1.62.22.73.23.8 4.3 4.95.45.96.5 48000.71.4 2.02.73.44.14.8 5.4 6.16.8 7.58.2 1/2" 60000 1.02.1 3.14.25.26.27.3 8.3 9.4 10.411.412.5 Note 1: A blank space indicates a pressure drop of over 50 PSI. Note 2: Other existing sources of pressure drop, (solenoid valves, etc.) must be considered. Note 3: A vertical run with a heat pump system always results in a liquid lift (heating or cooling). Note 4: The smallest liquid line diameter that results in a total liquid line pressure drop of 50 PSI or less results in the most reliable system (fewer pounds of R-410A). Note 5: It is recommended to place units where 1/2" liquid line is not required due to the increased refrigerant volume imposed by the larger liquid line. Note 6: At the time this manual was printed all outdoor units were rated with 3/8" liquid line. Table AC/IN-7-B — Allowable Vapor Line Diameters and BTUH Loss (R-410A Single Speed Systems) BTUH Loss For Equivalent Length Nominal Tube O.D. Press. Drop Tons (Inches) PSI/100 Ft.40' 60' 80' 100'120'140'160'180'200'220' 240' 1.0 1/2 5.0 70 160250 340430520610700790880 970 5/8 1.5 20 50 73 100130155180210235265 290 1/2 10.8 173 410 640 875 111013401575181020402275 2510 1.5 5/8 3.1 50 120185 250320385450520585655 720 3/4 1.2 20 45 70 95125150175200225255 280 5/8 5.4 115 270 430 585 740 8951050120513601515 1670 2.0 3/4 2.0 45 100160 215275330390445505560 620 5/8 8.2 220 515 810 1110140016951990229025852880 3175 2.5 3/4 3.0 80 190295 4055156207308409451055 1160 7/8 1.3 35 80130 175220270315365410455 505 5/8 11.7 380 8851390 1895240029053410391544254930 — 3.0 3/4 4.3 140 325 510 700 88010701255144016251810 2000 7/8 1.9 60 145225 310390470555635720800 880 3.5 3/4 5.8 220 510 805 1095139016801975226525602850 3140 7/8 2.5 95 220345 47560072585097511051230 1355 3/4 7.4 320 745 1170 1600202524502875330537304155 4580 4.0 7/8 3.2 140 325 510 690 87510601245143016151795 1980 1-1/83 .9 40 90145 195245300350400455505 555 3/4 11.5 62014502280 3105393547605590641572458073 8900 5.0 7/8 4.9 265 615 970 1325167520302380273530803440 3795 1-1/8 1.3 70165255 350445540630725820915 1005 Note 1: Shaded value indicates more than 10% capacity loss. Note 2: Blank space indicates more than 15% capacity loss. Note 3: Only approved for cooling units, do not use 1 1/8" vapor lines on heat pumps less than 5 ton. Note 4: If linear length exceeds 150 feet, add 2 ounces of approved compressor oil per every 10 feet in excess of 150 feet. (Example: if the actual line length is 170 feet, add 4 ounces of oil to the system) This page contains limited data to fully determine if the application will work or to select required accessories. Please refer to publication 14-4050-01 for complete details and examples. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AC/IN-7 Effective 7/1/12 14-1011-28 Refrigerant Piping Information for Allegiance/Heritage 16 & 20 Split Systems Table AC/IN-8-A — Allowable Vapor and Liquid Line Diameters for Multistage Split Systems Maximum Alternative Vapor Line OD Minimum Alternative Liquid Line OD Maximum Alternative Liquid Line OD OD Unit nominal capacity Rated Vapor Line OD Vapor Service Valve OD Minimum Alternative Vapor Line OD 2 ton CLG 5/8" 5/8" 5/8" 3/4" 5/16" 5/16" 5/16" 3/8" 3 ton CLG 3/4" 3/4" 5/8" 7/8" 3/8" 3/8" 5/16" 3/8" Rated Liquid Line OD Liquid Service Valve OD Allegiance/Heritage 16 4 ton CLG 7/8" 7/8" 3/4" 7/8" 3/8" 3/8" 3/8" 3/8" 5 ton CLG 7/8" or 1 1/8" 7/8" 3/4" 1 1/8" 3/8" 3/8" 3/8" 3/8" 2 ton HP 5/8" 5/8" 5/8" 3/4" 5/16" 5/16" 5/16" 3/8" 3 ton HP 3/4" 3/4" 5/8" 7/8" 3/8" 3/8" 5/16" 3/8" 4 ton HP 7/8" 7/8" 3/4" 7/8" 3/8" 3/8" 3/8" 3/8" 5 ton HP 7/8" or 1 1/8" 7/8" 3/4" 1 1/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 5/16" 3/8" Allegiance/Heritage 20 2 ton CLG 3/4" 5/8" 5/8" 3/4" 3 ton CLG 3/4" 3/4" 5/8" 7/8" 3/8" 3/8" 5/16" 3/8" 4 ton CLG 7/8" 3/4" 3/4" 7/8" 3/8" 3/8" 3/8" 3/8" 5 ton CLG 7/8" 3/4" 3/4" 7/8" 3/8" 3/8" 3/8" 3/8" 2 ton HP 5/8" 5/8" 5/8" 3/4" - 50 feet max length 3/8" 3/8" 5/16" 3/8" 3 ton HP 3/4" 3/4" 5/8" 3/4" 3/8" 3/8" 5/16" 3/8" 4 ton HP 3/4" 3/4" 3/4" 3/4" 3/8" 3/8" 3/8" 3/8" 5 ton HP 3/4" 3/4" 3/4" 7/8" - 50 feet max length 3/8" 3/8" 3/8" 3/8" Two compressor models share the same refrigeration circuit, however, do not operate simultaneously. Therefore, it is crucial that refrigerant lines be properly sized and do not exceed the length set forth in this guide. Please note it is recommended to use the service valve connection size tubing. A. Limitations: 1. Line length limits as shipped: A. Vapor line = 80 feet linear length / of the linear length, 25 feet may be installed vertical. B. Liquid line = 80 feet linear length / of the linear length, 25 feet may be installed vertical. B. Explanation: 1. Refrigerant lines shall not exceed 80 feet total line length. / 25 feet of the 80 feet may be vertical. A. Liquid sub-cooling may not be achieved on second stage if the liquid line exceeds 80 feet. B. Oil return may be sacrificed during first stage operation if the vapor line exceeds 80 feet. Equivalent Length (Ft.) of Non-Ferrous Valves and Fittings (Brazed) O.D. ShortLong Tee Tube SizeGlobeAngleRadiusRadius Tee Branch (Inches) Valve Valve Ell Ell Line Flow Flow 1/2*70 24 4.73.21.7 6.6 5/872 255.73.92.38.2 3/475 256.54.52.99.7 7/8 78 28 7.85.33.712.0 1-1/887 29 2.71.92.5 8.0 1-3/8 10233 3.22.22.710.0 1-5/8 11534 3.82.63.012.0 Information for this chart extracted by permission from A.R.I. Refrigerant Piping Data, page 28. * For smaller sizes, use 1/2" values. This page contains limited data to fully determine if the application will work or to select required accessories. Please refer to publication 14-4050-01 for complete details and examples. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AC/IN-8 Effective 7/1/12 14-1011-28 6-20 Ton Split Systems Table AC/IN-9-A — Cooling Component Selection Summary TTA073D TTA090D TTA120D TTA120E TTA120F TTA150E TTA180E TTA180F TTA240E TTA240F Refrigerant ckts UNIT 1 1 1 2 1 (Manifold) 2 2 1 (Manifold) 2 1 (Manifold) Minimum step (tons) 6 7.5 10 5 5 6.25 7.5 7.5 10 10 1 1/8 1 3/8 1 5/8 1 3/8 1 5/8 Gas Line Gas Line Tube diameter (in.) Horizontal (& drops) 1 1/8 Vertical (up) Acess port 3/ckt 1 3/8 1 3/8 1 1/8 1 3/8 1 1/8 1 3/8 1 3/8 1 1/8 1 1/8 1 1/8 1 3/8 1 3/8 1 3/8 1 5/8 Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* 1/2 5/8 1/2 1/2 1/2 1/2 5/8 1/2 5/8 LIQUID LINE LIQUID LINE Tube diameter (in.) Filter drier 1/2 DHY01123** DHY01232** DHY01123** DHY01123** DHY01123** DHY01123** DHY01123** DHY01131** DHY01123** DHY01132** Sight glass 1/ckt GLS00853 GLS00830 GLS00853 GLS00853 GLS00853 GLS00853 GLS00853 GLS00830 GLS00853 GLS00830 Access port 2/ckt Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Schraeder valve w/ core* Check valve selections: 3/8 = VAL08459, 1/2 = VAL08460, 5/8 = VAL01722 Table AC/IN-9-B — TWA Component Selection Summary TWA073D TWA090D TWA120D TWA180E Refrigerant ckts UNIT 1 1 1 2 TWA240E 2 Minimum step (tons) 6 7.5 10 7.5 10 Gas Line Tube diameter (in.) Horizontal (& drops) 1 1/8 1 3/8 1 3/8 1 3/8 1 3/8 Vertical (up) 1 1/8 1 3/8 1 3/8 1 3/8 1 3/8 Schraeder valve w/core* Schraeder valve w/core* Schraeder valve w/core* Schraeder valve w/core* Schraeder valve w/core* 1/2 5/8 1/2 1/2 5/8 Acess port 3/ckt LIQUID LINE Tube diameter (in.) Filter drier DHY01123 (QTY 2)** DHY01123 (QTY 2)** DHY01123 (QTY 2)** DHY01123 (QTY 2)** Sight glass 1/ckt GLS00853 GLS00830 GLS00853 GLS00853 GLS00853 Access port 2/ckt Schraeder valve w/core* Schraeder valve w/core* Schraeder valve w/core* Schraeder valve w/core* Schraeder valve w/core* Check valve selections: 3/8 = VAL08459, 1/2 = VAL08460, 5/8 = VAL01722 *Valve body VALO1483, valve core COR00006, valve cap CAP00072. **The heat pump products require two filters and two check valves: one set-oriented for liquid in the cooling direction, and one set-oriented for liquid in the heating direction. For units with line lengths in excess of 80 ft, the included filters must be removed and filters from the table must be installed close to the air handler. Table AC/IN-9-C — Expansion Valves for TTA/TWA 6-20 Ton Applications* Refrigerant Manufacturer Tonnage Range Model Number Part Number Model Number w/ Check Valve Part Number R-410A Sporlan 2-3 ERZE-2-ZGA VAL09476 RCZE-2.0-ZGA VAL08085 R-410A Sporlan 3-4 ERZE-3-ZGA VAL09477 RCZE-3.0-ZGA VAL08086 R-410A Sporlan 4-5 ERZE-4-ZGA VAL09478 RCZE-4.0-ZGA VAL08087 R-410A Sporlan 5-6 ERZE-5-ZGA VAL09479 RCZE-5.0-ZGA VAL08088 R-410A Sporlan 6-8 ERZE-6-ZGA VAL09480 RCZE-6.0-ZGA VAL08089 R-410A Sporlan 8-11 ERZE-8-ZGA VAL09481 — — R-410A Sporlan 11-14 ERZE-12½-ZGA VAL09482 — — R-410A Sporlan 14-17 ERZE-15-ZGA VAL09483 — — R-410A Sporlan 17-23 OZE-20-ZGA VAL09485 — — For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AC/IN-9 Effective 7/1/12 14-1011-28 6-20 Tons Split System Contact American Standard for review Contact American Standard for review Contact American Standard for review For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AC/IN-10 Effective 7/1/12 14-1011-28 Branch Circuit Wire Sizing Table/ Heater De-Rating Chart BRANCH CIRCUIT WIRE SIZING TABLE (Based on 2% Voltage Drop) Chart is based on 75˚ C. wire. (Types FEPW, RH, RHW, THHW, THW, THWN, XHHW, USE, AND ZW.) Use Chart For Wire Sizing Only. Refer To Electrical Code, (Or Product Specs.) For Fuse Sizing Suitable for 1 Ph. or 3 Ph. Circuits 10 10 15 15 20 25 30 75˚ C. Insulation; 30˚ C. Ambient Temp. (80˚ F.) Not more than three conductors per raceway DISTANCE (POWER SUPPLY TO LOAD) IN FEET (208-230V) 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 #12 Copper or #10 Aluminum 20 25 30 35 REQUIRED BRANCH CIRCUIT AMPACITY 40 45 50 55 60 65 70 75 80 #10 Copper or #8 Aluminum #8 Copper or #6 Aluminum #6 Copper or #4 Aluminum #4 Copper or #2 Aluminum 85 90 95 100 105 #2 Copper or #0 Aluminum 110 115 120 125 130 50 100 150 200 250 300 350 Distance (power supply to load in feet (460V). See National Electrical Code for Temperature corrections and other variables. All wiring must comply with Local Codes Heater De-Rating Chart The output of electric heaters, applied at voltages other than the rated 240 or 480 volts, can be easily determined with the use of this chart. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AC/IN-11 Effective 7/1/12 14-1011-28 Basic Air Conditioning Formulas Figure 5 Basic Air Conditioning Formulas TO DETERMINE Application Guide EXPRESSED AS HEATING and/or HUMIDIFYING COOLING 1. CFMT = NT V 60 min./hr. 2. CFMo = No V 60 min./hr. Total Airflow CFMT 1. CFMT = NT V 60 min./hr. Infiltration or Ventilation CFMo 2. CFMo = NO V 60 min./hr. Number of Air Changes Per Hour – Total NT 3. NT = CFMT (60 min./hr.) V 3. NT = CFMT (60 min./hr.) V Number of Air Changes Per Hour – Outdoor Air No 4. No = CFMo (60 min./hr.) V 4. No = CFMo (60 min./hr.) V Total Heat (HT) Btuh 5. HT = CFMT x 4.5 x (h1 – h2) = Btuh 6. HT = CFMT x 4.5 x (h2 – h1) = Btuh Sensible Heat (HS) Btuh 7. HS = CFMT x 1.08 x (T1 – T2) = Btuh 8. HS = CFMT x 1.08 x (T2 – T1) = Btuh Latent Heat (HL) Btuh 9. HL = CFMT x .68 x (W1 – W2) = Btuh 10. HL = CFMT x .68 x (W2 – W1) = Btuh Entering Air Temperature (T1) (Mixed Air) °F. D.B. CFMo x (t2 – t1) = °F.D.B. 1 CFMT 11. T1 = t1 + 1 If duct heat gain is a factor, add to T1: 2 If duct heat loss is a factor, subtract from T1: Duct Heat Loss (Btuh) CFMT x 1.08 Duct Heat Gain (Btuh) CFMT x 1.08 Leaving Air D.B. Temperature (T2) °F. D.B. 13. T2 = T1 – Required Airflow CFMT 15. CFMT = OR CFMT = HS CFMT x 1.08 CFMo x (t1 – t2) = °F.D.B. 2 CFMT 12. T1 = t1 – = °F.D.B. 14. T2 = T1 + HS (total) 1.08 x (T1 – T2) = CFM 16. CFMT = HS (internal)3 1.08 x (t1 – T2) = CFM HS CFMT x 1.08 HS 1.08 x (T2 – T1) = °F.D.B. = CFM 3 Sensible load of outside air not included HT CFMT x 4.5 HT CFMT x 4.5 Enthalpy – Leaving Air (h2) Btu/lb. dry air 17. h2 = h1 – Leaving Air W.B. Temperature °F.W.B. 19. Refer to Enthalpy Table and read W.B. temperature corresponding to enthalpy of leaving air (h2) (see #17). 20. Refer to Enthalpy Table and read W.B. temperature corresponding to enthalpy of leaving air (h2) (see #18). 21. HL = CFMo x .68 (W3 – Wo) = Btuh 22. HL = CFMo x .68 (W3 – Wo) = Btuh Heat Required to Evaporate Water Vapor Added to Ventilation Air Humidification Requirements Btuh Lbs. water/hr. 23. ( = Btu/lb. dry air Excess Latent Capacity Make up = of System x % Run Time 1060 Btu/lb. Moisture ) 18. h2 = h1 + (Industrial Process Work) LEGEND CFMT CFMo NT No V HT HS HL * h1 * h2 T1 T2 Tadp t1 t2 W1 W2 W3 Wo = = = = = = = = = = = = = = = = = = = ( ) 24. Make up = Moisture = lbs./hr. = Btu/lb. dry air HL loss Btuh (see #22) 1060 Btu/lb. = lbs./hr. DERIVATION OF AIR CONSTANTS Total airflow cubic feet/min. Outdoor air cubic feet/min. Total air changes per hour Outdoor air, air changes per hour Volume of space cubic feet Total heat Btuh Sensible heat Btuh Latent heat Btuh Enthalpy or total heat of entering air Enthalpy or total heat of leaving air Temperature of entering air Temperature of leaving air Apparatus dewpoint Indoor design temperature Outdoor design temperature Grains of water/lb. of dry air at entering condition Grains of water/lb. of dry air at leaving condition Grains of water/lb. of dry air at indoor design conditions Grains of water/lb. of dry air at outdoor design conditions The air constants below apply specifically to standard air which is defined as dry air at 70°F and 14.7 P.S.I.A. (29.92 in. mercury column). They can, however, be used in most cooling calculations unless extremely precise results are desired. 4.5 (To convert CFM to lbs./hr.) 4.5 = Btu/lb. Btu/lb. or 60 X .075 Where 13.33 is the specific volume of standard air (cu.ft./lb.) and .075 is the density (lbs./cu.ft.) 1.08 = °F.D.B. °F.D.B. °F.D.B. Grains/lb. Grains/lb. Grains/lb. Grains/lb. 60 min./hr. 13.33 .24 X 60 13.33 or .24 X 4.5 .24 BTU = specific heat of standard air (BTU/LB/°F) .68 = 60 13.33 X 1060 7000 or 4.5 X 1060 7000 Where: 1060 = Average Latent Heat of water vapor (BTU/LB.). 7000 = Grains per lb. * See Enthalpy of air (Total Heat Content of Air) Table for exact values. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AC/IN-12 Effective 7/1/12 14-1011-28 Low Ambient Accessories Cooling and Heating Models Table AC/IN-13-A — Low Ambient Accessories Cooling Models Low Ambient Accessory For American Standard Residential Cooling Units 55°F Cooling Unit O°F to 30° or 20°F to 30°F - Please Reference Lowest Approved Outdoor Operating Temperature per Model Family Table 30°F to 55°F As Manufactured AY28X079 TXV-NB CCHT BAYACHP024 BAYLOAM103 AY28X079 TXV-NB Compressor Liquid Line Crankcase Solenoid Start Kit Heater Windshield Valve 4A7C31 X X X — — X X X N/A — X X 4TTB3/4A7B31 X X X X — X X X X X X X 4A7B4018-0601 X X X X — X X X X X X X 4A7A32 X X X X — X X X X X X X 4A7A5018-0602 X X X X — X X X X X X X 4A7A64 X 4A7Z03 X X X X Not Approved — Not Approved Not Approved Table AC/IN-13-B — Low Ambient Accessories Heating Models Low Ambient Accessory For American Standard Residential Heat Pump Units 55°F Heat Pump Unit O°F to 30° or 20°F to 30°F - Please Reference Lowest Approved Outdoor Operating Temperature per Model Family Table 30°F to 55°F As Manufactured AY28X079 TXV-NB CCHT BAYACHP024 BAYLOAM103 AY28X084 TXV-NB Start Kit Compressor Liquid Line Crankcase Solenoid Heater Windshield Valve 4A6C31 X X X X — X X X N/A — X — 4TWB3/4A6B31 X X X X — X X X X X X — 4A6B41 X X X X — X X X X X X — 4A6H5018-0602 X X X X — X X X X X X — 4A6H32 X X X X — X X X X X X — 4A6H64 X 4A6Z03 X X X X Not Approved — Not Approved Not Approved Charts are for quick reference only. For complete application guidelines, consult the specific SSC-APG***. 1 Reference AMSSP-APG001-EN for complete Low Ambient Guidelines. 2 Reference AMSSP-APG002-EN for complete Low Ambient Guidelines. 3 Reference SSC-APG008-EN for complete Low Ambient Guidelines. 4 Reference APP-APG014-EN. Lowest Approved Outdoor Operating Temperature for Cooling Operation per Model Family Table Model Family Lowest Approved OD Ambient 4A7Z0/4A6Z0 55°F 4A7A6/4A6H6 30°F 4A7A5018-060/4A6H5 20°F 4A7A3/4A6H3 0°F 4A7B4018-060/4A6B4 20°F 4TTB3/4A7B3/4TWB3/4A6B3 0°F 4A7C3/4A6C3 0°F For a detailed Application Bulletin on required accessories and wind shields for low outdoor ambient operation, please contact your Territory Manager or Local FSR. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AC/IN-13 Effective 7/1/12 14-1011-28 Wind Shields Wind Shields are required to block prevailing winds across condenser coil. In applications where cooling operation is required to 0°F, wind shields are a Must. Use the following guidelines for your application. Notes: Minimum working clearance must be in compliance with the National Electric Code. Currently, the minimum clearance between a wood or suitable grounding material type fence requires minimum 3 feet. If other material is used to form the windshield, the minimum space may be increased to 3.5 feet. Please consult the 2006 Edition of the National Electric Code, Article 110 for the most up to date information, please refer to the most current National Electric Code. For a detailed Application Bulletin on required accessories and wind shields for low outdoor ambient operation, please contact your Territory Manager or Local FSR. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. AC/IN-14 Effective 7/1/12 14-1011-28 Water to Air Packaged Units 1GX - 2GX Water 1GX - 2GX Water Source Heat Pumps A Source Heat Pumps 1GC Water Source 1GC Source HeatWater Pumps Heat Pumps 1 G X 0 2 2 T R R 1 0 C 0 Brand A = American Standard Brand A = American Standard *Compressor Type 1 = Single Stage Compressor 2 = Two Stage Compressor Compressor Type 1 = Single Stage Compressor A 1 G C 0 2 4 T R R 1 0 C 0 A Product Category G = Geothermal Product Category G = Geothermal Product Type C = Conventional Packaged System (Water-to-Air) Product Type X = Premium Packaged System (Water-to-Air) Nominal BTU’s Thousands of BTU’s Nominal BTU’s Thousands of BTU’s *Discharge Air Configuration T = Top (Vertical) E = End (Horizontal) S = Side (Horizontal) *Discharge Air Configuration T = Top (Vertical) B = Bottom (Vertical) E = End (Horizontal) S = Side (Horizontal) R = Rear (Vertical 042-072 Only) *Return Air Configuration L = Left Painted R = Right Painted Heating and/or Cooling R = Heating and Cooling *Return Air Configuration L = Left Painted R = Right Painted Voltage/Frequency/Phases 1 = 208-230/60/1 Heating and/or Cooling R = Heating and Cooling *Hot Water Options 0 = No Hot Water, No GeoStart 1 = Hot Water Generator with factory installed pump, No GeoStart 3 = No Hot Water, GeoStart 4 = Hot Water Generator with factory installed pump, GeoStart Voltage/Frequency/Phases 1 = 208-230/60/1 *Hot Water Options 0 = No Hot Water, No GeoStart 1 = Hot Water Generator with factory installed pump, No GeoStart 3 = No Hot Water, GeoStart 4 = Hot Water Generator with factory installed pump, GeoStart *Coax Options C = Copper N = Cupronickel *Blower Motor Options 0 = PSC 3 = Oversized PSC Blower Option (022, 030, 036, 042, 048 Only) 4 = X13 *Coax Options C = Copper N = Cupronickel *Blower Motor Options 0 = PSC 1 = ECM Blower 2 = Oversized ECM Blower Option (036, 038, 042, 048, 049 Only) 3 = Oversized PSC Blower Option (022, 030, 036, 042, 048 Only) Vintage Current Vintage of the Product Capacities Single = 022, 030, 036, 042, 048, 060, 070 Dual = 26, 038, 049, 064, 072 *Select desired options to create specific model number. Note: All models have sound kits. Capacities Single = 024, 030, 036, 042, 048, 060, 070 *Select desired options to create specific model number. Note: All models have sound kits. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-1 Effective 7/1/12 14-1011-28 Water to Air Packaged Units • Extended range operation (20-120˚F EWT) • Earth friendly R-410A refrigerant • Premier 2 microprocessor based controls with fault indicator lights • Comfort Alert™ compressor monitor • Copeland single speed or dual capacity scroll compressor • PSC Motor or ECM variable speed fan motor • FormiShield™ coated air coil • Internal expansion valve • Optional internal electric heat • 1" Swivel fittings • Special gray color powder coated heavy gauge galvanized cabinet • Factory computer run test • ARI/ASHRAE/ISO 13256-1 performance certified and UL/ETL safety listed • 2" Filter Rack with MERV 11 filter Included • Horizontal Hanger Kit Included • 10-year parts and 10-year labor allowance Table GEO-2-A — 1GX - 2GX Water Source Heat Pumps Norminal Cooling Unit Power Supply Capacity (Btuh) Dimensions (in.)1 Shipping Nominal Supply Nominal Return Filter Model No. Volts/Hz/Phase ECM 2 Motor H x W x L Weight (Ibs.) Opening (WxD)1 Opening (DxH)1Size 1 Water Inlet/ Min Circ Amp Max Outlet Size ECM 2 Motor Fuse A1GX022 A2GX026 A1GX030 A1GX036 A2GX038 A1GX042 A1GX048 A2GX049 A1GX060 A2GX064 A1GX070 A2GX072 1" Swivel 1" Swivel 1" Swivel 1" Swivel 1" Swivel 1" Swivel 1" Swivel 1" Swivel 1" Swivel 1" Swivel 1" Swivel 1" Swivel 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 21,700 27,200 29,400 35,000 40,200 42,000 49,300 50,000 66,800 67,600 73,200 73,600 48.4x22.3x26.3 48.4x22.3x26.3 48.4x22.3x26.3 50.4x25.4x31.4 50.4x25.4x31.4 54.4x25.4x31.4 54.4x25.4x31.4 54.4x25.4x31.4 58.4x25.4x31.4 58.4x25.4x31.4 58.4x25.4x31.4 58.4x25.4x31.4 313 313 328 373 378 388 428 428 463 473 488 488 14x14 14x14 14x14 18x18 18x18 18x18 18x18 18x18 18x18 18x18 18x18 18x18 22x26 22x26 22x26 28x26 28x26 28x30 28x30 28x30 28x34 28x34 28x34 28x34 28x24 28x24 28x24 28x30 28x30 32x30 32x30 32x30 36x30 36x30 36x30 36x30 15.2 16.8 20.0 21.6 24.8 24.8 28.8 30.4 40.0 39.0 44.6 41.0 20 25 30 35 40 40 45 50 60 60 70 60 1Vertical Applications. * For models not listed and unit details, please refer to the Geothermal/Water Source Heat Pump Product Data publication. • Extended Range operation (20-120˚F EWT) • Earth friendly R-410A Refrigerant • Standard microprocessor controls with LED status and fault lights • Copeland Single Speed Scroll Compressor • X-13 ECM motor or 3 speed PSC fan motor • Coated air coil • Internal Expansion valve • Optional internal electric heat • 1" Swivel fittings • Special gray color powder coated heavy gauge galvanized cabinet • Factory computer run test • ARI/ASHRAE/ISO 13256-1 performance certified and UL/ETL safety listed • Horizontal hanger kit Included • 1" filter rack with MERV 8 filter Included • 10-year Parts and 10-year labor allowance Table GEO-2-B — 1GC Water Source Heat Pump Norminal Cooling Unit Power Supply Capacity (Btuh) Dimensions (in.) Shipping Nominal Supply Nominal Return Model No. Volts/Hz/Phase X13 Motor H x W x L Weight (Ibs.) Opening (WxD)1 Opening (DxH)1 A1GC024 A1GC030 A1GC036 A1GC042 A1GC048 A1GC060 A1GC070 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 24,400 29,000 34,500 42,300 49,500 60,900 68,500 44.4X22.3X26.3 44.4X22.3X26.3 48.4X22.3X26.3 50.4X25.4X31.4 50.4X25.4X31.4 54.4X25.4X31.4 58.4X25.4X31.4 288 299 307 379 388 448 483 14x14 14x14 14x14 18x18 18x18 18x18 18x18 22x22 22x22 22x26 28x26 28x26 28x30 28x34 Filter Size 24X24 24X24 28X24 28X30 28X30 32X30 36X30 Water Inlet/ Min Circ Amp Max Outlet Size X13 Motor Fuse 1" Swivel 1" Swivel 1" Swivel 1" Swivel 1" Swivel 1" Swivel 1" Swivel 26.8 27.5 31.5 38.4 39.7 46.3 51.0 40 40 45 50 60 70 80 1Vertical Applications. * For models not listed and unit details, please refer to the Geothermal/Water Source Heat Pump Product Data publication. Models listed are representative ONLY. Please refer to model nomenclature for product line configuration. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-2 Effective 7/1/12 14-1011-28 Water to Air Packaged Units Table GEO-3-A — Optional Accessories 1GX - 2GX Model Number Description Vertical Auxiliary Heaters EAM5 1 EAM8 1 EAM10 1 EAL10 1 EAL15 1 EAL20 1 Horizontal Auxiliary Heaters EAMH5 2 EAMH8 2 EAMH10 2 EALH10 2 EALH15 2 EALH20 2 Air Pads for Vertical Topflow Units AP2430 AP= High density plastic AP32 AP= High density plastic APF2634 APF= 2" PEX foam, cutable Thermostats (All Controls- 3H, 2C, Dual Fuel Compatible) 950 Premium Control (Requires Relay Panel) 24 Volt Interface Relay Panel for 950 Control Programmable Touch Screen Digital Control Non-Programmable Comfort Control Disposable Pleated Filters, 2" MERV113 59P509-04 Vertical Units (24x28)4 59P509-08 Vertical Units (28x30) 59P509-07 Vertical Units (30x32) 59P509-06 Vertical Units (30x36)5 59P509-09 Horizontal Units (18x32) 59P509-10 Horizontal Units (20x37) 59P509-02 Horizontal Units (20x20) 59P509-11 Horizontal Units (20x22) 59P509-03 Horizontal Units (20x25) Used With Single Speed Models Dual Capacity Models 022, 030 030 030 036, 042, 048, 060, 070 036, 042, 048, 060, 070 048, 060, 070 026 026 026 038, 049, 064, 072 038, 049, 064, 072 049, 064, 072 022,030 022,030 030 036, 042, 048, 060, 070 036, 042, 048, 060, 070 048, 060, 070 026 026 026 038, 049, 064, 072 038, 049, 064, 072 049, 064, 072 022, 030 036, 042, 048, 060, 070 022, 030, 036, 042, 048, 060, 070 026 038, 049, 064, 072 026, 038, 049, 064, 072 022, 030 036 042, 048 060, 070 022, 030 036 042, 048 042, 048, 060, 070 060, 070 026 038 049 064, 072 026 049 049 049, 064, 072 064, 072 1Internal Mount, Electronic Control Board, Sequenced Operation, 15-20kW include internal fuses. 2Internal mount control box, coil assembly external mount, Electronic Control Board, Sequenced Operation, 15-20kW include internal fuses (Use on Horizontal & Rear Discharge Units). 36 month life (Minimum order qty. 2). 4Bottom flow 22-30 5Bottom flow 36-72 For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-3 Effective 7/1/12 14-1011-28 Water to Air Packaged Units Table GEO-4-A — Optional Accessories 1GC Model Number Description Used With Vertical Auxiliary Heaters EAM5 1 022, 030 EAM8 1 030 EAM10 1 030 EAL10 1 036, 042, 048, 060, 070 EAL15 1 036, 042, 048, 060, 070 EAL20 1 048, 060, 070 Horizontal Auxiliary Heaters EAMH5 2 022,030 EAMH8 2 022,030 EAMH10 2 030 EALH10 2 036, 042, 048, 060, 070 EALH15 2 036, 042, 048, 060, 070 EALH20 2 048, 060, 070 Air Pads for Vertical Topflow Units AP2430 AP= High density plastic 022, 030 AP32 AP= High density plastic 036, 042, 048, 060, 070 APF2634 APF= 2" PEX foam, cutable 022, 030, 036, 042, 048, 060, 070 Thermostats (All Controls- 3H, 2C, Dual Fuel Compatible) 950 Premium Control (Requires Relay Panel) 24 Volt Interface Relay Panel for 950 Control Programmable Touch Screen Digital Control Non-Programmable Comfort Control Disposable Pleated Filters 59P503B27 Vertical Units (24x24) 024, 030 59P503B05 Vertical Units (24x28) 036 59P503B28 Vertical Units (30x28) 042, 048 59P503B21 Vertical Units (30x32) 060 59P503B04 Vertical Units (30x36) 070 59P503B23 Horizontal Units (18x32) 024, 030, 036 59P503B08 Horizontal Units (20x37) 042, 048, 070 59P503B02 Horizontal Units3 060 59P503B24 Horizontal Units3 060 59P503B03 Horizontal Units4070 59P503B24 Horizontal Units4070 1Internal Mount, Electronic Control Board, Sequenced Operation, 15-20kW include internal fuses. 2Internal mount control box, coil assembly external mount, Electronic Control Board, Sequenced Operation, 15-20kW include internal fuses (Use on Horizontal & Rear Discharge Units). 3Use 1 - 20x20 and 1 - 20x22. 4Use 1 - 20x25 and 1 - 20x22. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-4 Effective 7/1/12 14-1011-28 Water to Water Packaged Units 1GW Water 1GW Water Units Packaged Packaged Units 2GW Water 2GW Water Units Packaged Packaged Units A 1 G W 0 4 0 N N H 1 0 C N A 2 G W 1 0 0 T N R 1 0 B N Brand A = American Standard Brand A = American Standard Compressor Type 1 = Single Stage Compressor Compressor Type 2 = Two Stage Compressor Product Category G = Geothermal Product Category G = Geothermal Product Type W= Hydronic Packaged System (Water-to-Water) Product Type W= Hydronic Packaged System (Water-to-Water) Nominal BTU’s Thousands of BTU’s Nominal BTU’s Thousands of BTU’s Discharge Air Configuration N = None Discharge Configuration T = Top Mounted Connections R = Rear Mounted Connections Return Air Configuration N = None Return Air Configuration N = None *Heating and/or Cooling1 H = Heating Only R = Heating and Cooling (Reversible) Heating and/or Cooling R = Heating and Cooling (Reversible) Voltage/Frequency/Phases 1 = 208-230/60/1 Voltage/Frequency/Phases 1 = 208-230/60/1 *Hot Water Options1 0 = No Hot Water, No GeoStart 2 = Hot Water Generator without factory installed pump, No GeoStart 3 = No Hot Water, GeoStart 5 = Hot Water Generator without factory installed pump, GeoStart Hot Water Options 0 = No Hot Water, No GeoStart 3 = No Hot Water, GeoStart Coax Options B = Brazed plate *Coax Options2 C = Copper N = Cupronickel L = Source Cupronickel / Load Copper S = Source Copper / Load Cupronickel Blower Motor Options N = None Blower Motor Options N = None 1 Available on 040-075 only. Hot Water Generator requires field installed external pump kit. 2 018-025 heating only models are avaliable only with copper double wall vented load coax for potabale water. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-5 Effective 7/1/12 14-1011-28 Water to Water Packaged Units 1GW Series • Extended range operation (20-120˚F EWT) • Earth friendly R-410A refrigerant • GW series microprocessor based controls • Scroll (single speed) compressors • Expansion valve • Special gray powder coated cabinet • Factory computer run test • ARI/ASHRAE/ISO 13256-1 performance certified and UL/ETL safety listed • Fully insulated cabinet, coax HE, water piping and ref. lines • Adjust temperature and configuration from control panel on front of units • 10-year parts and 10-year labor allowance 2GW Series • Ultra-compact 25"W x 33"D x 24"H • Standard waterlines out the back or front (field convertible via control box) • Factory optional top waterlines • High efficiency brazed plate heat exchanger • High efficiency scroll compressors (2) • Optional GeoStart • FX10 control package with MUI interface • Performance monitoring and communication through standard DDC protocols • 10-year parts and 10-year labor allowance Table GEO-6-A — 1GW - 2GW Hydronic Heat Pumps Unit Model No. Power Supply Refrigerant Volts/Hz/Phase Norminal Cooling Capacity (Btuh) Norminal Heating Capacity (Btuh) Dimensions (in.) H x W x D Shipping Water Supply and Weight (Ibs.) Return Size Min Circ Amp Max Fuse A1GW018 208-230/60/1 17,300 15,000 26.1x19.5x23.5 213 1 20.1 30 A1GW025 208-230/60/1 24,700 22,000 26.1x19.5x23.5 247 1 24.1 35 A1GW040 208-230/60/1 37,700 31,000 26.2x22.0x31.0 305 1 32.2 50 A1GW050 208-230/60/1 51,500 44,000 26.2x22.0x31.0 340 11/4 40.2 60 A1GW060 208-230/60/1 58,000 50,000 26.2x22.0x31.0 360 11/4 44.870 A1GW075 208-230/60/1 68,400 62,000 26.2x22.0x31.1 360 11/4 40.8 60 A2GW100 208-230/60/1 100,000 82,000 24.1x25.58x33.6 385 2 33.0/41.4 50/60 A2GW120 208-230/60/1 114,000 93,000 24.1x25.58x33.6 395 2 37.6/46.0 60/70 A2GW150 208-230/60/1 147,000 123,000 24.1x25.58x33.6 395 2 33.6/42.0 60/60 A2GW180 208-230/60/1 165,000 139,000 24.1x25.58x33.6 415 2 40.1/48.5 70/80 *For models not listed and unit details, please refer to the Geothermal Hydronic Heat Pump Product Data publication. Models listed are representative ONLY. Please refer to model nomenclature for product line configuration. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-6 Effective 7/1/12 14-1011-28 Water to Water Packaged Units Table GEO-7-A — Optional Accessories GW1 Model Number Description Circulating Pump Kits 24S516-10 Load-side low flow pump (Potable Water) EWPK11 Load-side pump kit, 1" cast iron volute EWPK2 Load-side pump kit, 1" bronze volute EWPK31 Load-side pump kit, 1 1/4" cast iron volute 13P003B Low voltage pump signal relay (combined source pumps) Water Connection Kits MA4FPT 1" MPT x 1" FPT w/1/4 tap, Load Side W-W MA5FPT 1 1/4" MPT x 1" FPT w/1/4 tap, Load Side W-W HKC8S Stainless steel hose kit 1" HKC10S Stainless steel hose kit 1 1/4" Hot Water Generatorer Pump Kit DPK5 Includes 230v 1/25 hp pump and fittings Air Pads AP2430 AP= High density plastic AP32 AP= High density plastic APF2428 2" PEX foam, cutable APF2634 2" PEX foam, cutable Used With 018, 025 018, 025, 040 018, 025 050, 060, 075 018, 025, 040, 050, 060, 075 018, 025, 040 050, 060, 075 018, 025, 040 050, 060, 075 040, 050, 060, 075 018, 025, 040 050, 060, 075 018, 025 040, 050, 060, 075 1Not for use in 018 and 025 potable water applications. Table GEO-7-B — Optional Accessories GW2 Model Number Description Hose Kits2 HHK162S 2" Stainless Steel hose kit, Y-Strainer, ball valves, and end fittings Water Connection Kit1 CKNDW1 Source side OR Load side unit fittings, P/T plugs Large Flow Centers2 FCL1-5028 1 Grundfos 3 speed pump (28 feet of head at 50 GPM) FCL2-5028 2 Grundfos 3 speed pump (56 feet of head at 50 GPM) FCL1-5038 1 Grundfos 3 speed pump (38 feet of head at 50 GPM) FCL2-5038 2 Grundfos 3 speed pump (76 feet of head at 50 GPM) FCL1-5055 1 Grundfos 3 speed pump (55 feet of head at 50 GPM) FCL2-5055 2 Grundfos 3 speed pump (110 feet of head at 50 GPM Load-Side Pump (pump and 2 "GL" fittings)2 PML32-160 1 Grundfos 3 speed pump (28 feet of head at 50 GPM) PML40-160 1 Grundfos 3 speed pump (38 feet of head at 50 GPM) PML40-240 1 Grundfos 3 speed pump (55 feet of head at 50 GPM) Large Flow Centers Fittings (sets of 2)2 GL6FPT 1.5" FPT X 2" GeoLink GL8FPT 2" FPT X 2" GeoLink GL-FPL Flushing Adapter Flow Switch Kit FPS300 Flow Switch Kit 1This part can be used for both load and source side. 2 kits will need to be purchased for fittings for both sides. 2Drop shipped from vendor. Does not include freight. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-7 Effective 7/1/12 14-1011-28 Triple Function Hybrid Water to Air Systems GY Series GY Series Hybrid Systems Hybrid Systems A 2 G Y 0 3 8 T R R 1 0 C 1 A Brand A = American Standard Compressor Type 2 = Single Stage Compressor Product Category G = Geothermal Product Type Y = Premium Packaged System (Water-to-Air plus Radiant Heating) Nominal BTU’s Thousands of BTU’s *Discharge Air Configuration T = Top (Vertical) R = Rear (Vertical 049-072 Only) *Return Air Configuration L = Left Painted R = Right Painted Heating and/or Cooling R = Heating and Cooling Voltage/Frequency/Phases 1 = 208-230/60/1 *Hot Water Options 0 = No Hot Water, No GeoStart 2 = Hot Water Generator without factory installed pump (022-072 Only) No GeoStart 3 = No Hot Water, GeoStart 5 = Hot Water Generator without factory installed pump (022-072 Only) GeoStart *Coax Options C = Copper N = Cupronickel L = Source Cupronickel/Load Copper S = Source Copper/Load Cupronickel *Blower Motor Options 1 = ECM Blower 2 = Oversized ECM Blower (038 & 049 Only) Vintage A = Current Vintage Capacities Two Stage = 038, 049, 064, 072 *Select desired options to create specific model number. Note: The factory installed water option (hot water generator) does not include factory mounted circulating pump or temperature control. DPK5 (ordered seperately) includes field installed circulator, hot water tank adaptor, temperature limit and installation instructions. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-8 Effective 7/1/12 14-1011-28 Triple Function Hybrid Water to Air Systems GEO STORAGE TANK • Extended range operation (20-120˚F EWT) • Hybrid "3 in 1" system-space heat, space cool, hot water to radiant floor zones • Optional hot water generator • Earth friendly R-410A refrigerant • Premier 2 microprocessor based controls • Copeland dual capacity scroll Compressor • ECM variable speed fan motor • FormiShield™ coated air coil • Expansion valve • Optional internal electric heat • 1" Swivel fittings • Special gray powder coated heavy gauge galvanized cabinet • Factory computer run test • ARI/ASHRAE/ISO 13256-1 performance certified and UL/ETL safety listed • 2" filter rack with MERV 11 filter Included • 10-year parts and 10-year labor allowance Table GEO-9-A — GY Series Hybrid Systems Unit Model No. Power Supply Norminal Cooling Volts/Hz/Phase Capacity (Btuh) A2GY038 A2GY049 A2GY064 A2GY072 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 35,200 43,800 59,400 69,100 Dimensions (in.) H x W x L Shipping Weight (Ibs.) Supply Opening (WxD) Return Opening (DxH) Filter Size Water Inlet/ Outlet Size Min Circ Amp Max Fuse 50.4x25.6x31.6 54.4x25.6x31.6 58.4x25.6x31.6 58.4x25.6x31.6 445 550 560 560 18x18 18x18 18x18 18x18 28x26 28x30 28x34 28x34 28x30 32x30 36x30 36x30 1" Swivel 1" Swivel 1" Swivel 1" Swivel 31.2 36.8 45.5 47.5 45 50 70 70 * For models not listed and unit details, please refer to the Geothermal Heat Pump with Water Heating for Radiant Floor Applications Product Data publication. Table GEO-9-B — Optional Accessories Model Number Description Disposable Pleated Filters, 2" MERV111 59P509-08 Vertical Units (28x30) 59P509-07 Vertical Units (30x32) 59P509-06 Vertical Units (30x36) Air Pads for Vertical Units AP32 AP - High density plastic APF2634 APF - 2” PEX foam, cutable Vertical Auxiliary Heaters EAL103 Vertical Auxiliary Heaters EAL153 Vertical Auxiliary Heaters EAL203 Vertical Auxiliary Heaters Horizontal Auxiliary Heaters EALH104 Horizontal Units (Rear Discharge Units Only) EALH154 Horizontal Units (Rear Discharge Units Only) EALH204 Horizontal Units (Rear Discharge Units Only) Hot Water Generator Pump Kit DPK55 Thermostats (All Controls- 3H, 2C, Dual Fuel Compatible) 950 Premium Control (Requires Relay Panel) 24 Volt Interface Relay Panel for 950 Control Programmable Touch Screen Digital Control Non-Programmable Comfort Control Used With 038 049 064, 072 038, 049, 064, 072 038, 049, 064, 072 038, 049, 064, 072 038, 049, 064, 072 049, 064, 072 038, 049, 064, 072 038, 049, 064, 072 049, 064, 072 038, 049, 064, 072 1Minimum order qty. 2. 2Bottom Flow 36-72. 3Sequenced Operation, 15-20kW include internal fuses. 4Sequenced Operation, 15-20kW include internal fuses. Rear discharge units only. 5Must be purchased with any Y with hot water generator option. Note: For hydronic accessories, please see hydronic price book. Models listed are representative ONLY. Please refer to model nomenclature for product line configuration. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-9 Effective 7/1/12 14-1011-28 Split Heat Pump Units 1GN - 2GN Indoor 1GN -Heat 2GN Indoor Split Pumps Split Heat Pumps A 1 G N 0 2 2 N N R 1 0 C N GE Outdoor GE Outdoor Split Heat Pumps Split Heat Pumps Brand A = American Standard Brand A = American Standard *Compressor Type 1 = Single Stage Compressor 2 = Two Stage Compressor Compressor Type 2 = Two Stage Compressor Product Category G = Geothermal Product Type N = Premium Split System Interior Grade Nominal BTU’s Thousands of BTU’s Discharge Air Configuration N = None Return Air Configuration N = None Heating and/or Cooling R = Heating and Cooling Voltage/Frequency/Phases 1 = 208-230/60/1 *Hot Water Options 0 = No Hot Water, No GeoStart 1 = Hot Water Generator with external factory pump, No GeoStart 3 = No Hot Water, GeoStart 4 = Hot Water Generator with external factory pump, GeoStart *Coax Options C = Copper N = Cupronickel A 2 G E 0 2 6 N N R 1 0 C N Product Category G = Geothermal Product Type E = Premium Split System Exterior Grade Nominal BTU’s Thousands of BTU’s Discharge Air Configuration N = None Return Air Configuration N = None Heating and/or Cooling R = Heating and Cooling Voltage/Frequency/Phases 1 = 208-230/60/1 *Hot Water Options 0 = No Hot Water, No GeoStart 3 = No Hot Water, GeoStart *Coax Options C = Copper N = Cupronickel Blower Motor Options N = None Blower Motor Options N = None Capacities Dual = 026, 038, 049, 064, 072 Capacities Single = 022, 030, 036, 042, 048, 060, 070 Dual = 026, 038, 049, 064, 072 *Select desired options to create specific model number. *Select desired options to create specific model number. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-10 Effective 7/1/12 14-1011-28 Split Heat Pump Units • Special gray powder coated heavy gauge galvanized cabinet • Accumulator on all models • Factory computer run test • ARI/ASHRAE/ISO 13256-1 performance certified and UL/ETL safety listed • 10-year parts and 10-year labor allowance • Extended range operation (20-120˚F EWT) • Earth friendly R-410A refrigerant • Copeland single speed or dual capacity scroll compressor • Premier 2 microprocessor based controls with fault Indicator Lights • Expansion valve • 1" Swivel fittings Table GEO-11-A — 1GN - 2GN Indoor Split Heat Pumps Unit Model No. Power Supply Volts/Hz/Phase A1GN022 A2GN026 A1GN030 A1GN036 A2GN038 A1GN042 A1GN048 A2GN049 A1GN060 A2GN064 A1GN070 A2GN072 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Norminal Cooling Capacity (Btuh) Dimensions (in.) H x W x L 21,800 26,200 26,800 31,900 35,000 39,900 46,200 47,700 57,000 59,100 63,200 62,700 19.5x22.5x26.5 19.5x22.5x26.5 19.5x22.5x26.5 21.25x25.5x31.5 21.25x25.5x31.5 21.25x25.5x31.5 21.25x25.5x31.5 21.25x25.5x31.5 21.25x25.5x31.5 21.25x25.5x31.5 21.25x25.5x31.5 21.25x25.5x31.5 Shipping Refrigerant Refrigerant Min Circ Max Weight (Ibs.) Suction Line 1 Liquid Line 1Amp Fuse 184 209 194 232 256 233 266 270 271 291 312 310 /8 /8 5 /8 5 /8 3 /4 3 /4 3 /4 3 /4 7 /8 7 /8 7 /8 7 /8 /8 /8 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 1 /2 1 /2 1 /2 1 /2 5 3 5 3 17.1 18.6 21.8 23.4 26.6 26.6 30.6 32.2 38.8 37.8 43.4 39.8 25 25 30 35 40 40 50 50 60 60 70 60 120' Line Set Length. Consult Guide for other lengths. * For models not listed and unit details, please refer to the Geothermal Indoor Split Heat Pump Product Data publication. Table GEO-11-B — Optional Accessories Model Number Description Air Pads AP2430 AP= High density plastic AP32 AP= High density plastic APF2428 APF= 2" PEX foam, cutable APF2634 APF= 2" PEX foam, cutable Thermostats (All Controls- 3H, 2C, Dual Fuel Compatible) 950 Premium Control (Requires Relay Panel) 24 Volt Interface Relay Panel for 950 Control Programmable Touch Screen Digital Control Non-Programmable Comfort Control Used With 022, 030 036, 042, 048, 060, 070, 026, 038, 049, 064, 072 022, 030 026, 038, 049, 064, 072 Models listed are representative ONLY. Please refer to model nomenclature for product line configuration. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-11 Effective 7/1/12 14-1011-28 Split Heat Pump Units • Accumulator on all models • Factory computer run test • ARI/ASHRAE/ISO 13256-1 performance certified and UL/ETL safety listed • Internally mounted flow center in cabinet (field Installed) • 10-year parts and 10-year labor allowance • Extended range operation (20-120°F EWT) • Earth Friendly R-410A Refrigerant • Rated for outdoor installation • Premier 2 microprocessor based controls with fault indicator lights • Copeland 2 stage scroll compressor • Expansion valve • Gray powder coated heavy gauge galvanized cabinet Table GEO-12-A — 2GE Outdoor Split Heat Pumps Unit Model No. Power Supply Volts/Hz/Phase A2GE026 A2GE038 A2GE049 A2GE064 A2GE072 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Norminal Cooling Capacity (Btuh) Dimensions (in.) H x W x L 26,200 35,000 47,700 59,100 62,700 26.7x36.0x23.9 26.7x36.0x23.9 26.7x36.0x23.9 26.7x36.0x23.9 26.7x36.0x23.9 Shipping Refrigerant Refrigerant Min Circ Max Weight (Ibs.) Suction Line 1 Liquid Line 1Amp Fuse 209 256 270 291 310 /8 /4 3 /4 7 /8 7 /8 /8 /8 3 /8 1 /2 1 /2 5 3 3 3 17 23.4 27.9 32.4 34 25 40 50 60 60 120' Line Set Length. Consult Guide for other lengths. * For models not listed and unit details, please refer to the Geothermal/Water Source Outdoor Split Heat Pump Product Data publication. Table GEO-12-B — Optional Accessories Model Number Description Mounting Pad AP3042 Bramec III, 6"x 6" modular construction Thermostats (All Controls- 3H, 2C, Dual Fuel Compatible) 950 Premium Control (Requires Relay Panel) 24 Volt Interface Relay Panel for 950 Control Programmable Touch Screen Digital Control Non-Programmable Comfort Control All GE Unit Sizes Models listed are representative ONLY. Please refer to model nomenclature for product line configuration. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-12 Effective 7/1/12 14-1011-28 Split Air Handlers and Coils GA Split System GA Split System Air Handlers Air Handlers GCX Coils CGX Coils A G A 2 2 R 0 0 0 1 1 M S A Brand A = American Standard Brand A = American Standard Product Category G = Geothermal Product Category G = Geothermal Product Type A = Split System Air Handler Product Type C = Split System Dual Fuel Coil Unit Capacity Refrigerant Models 22 = 022 M bthu 26 = 026 M bthu 30 = 030 M bthu 36 = 036 M bthu 42 = 042 M bthu 48 = 048 M bthu 60 = 060 M bthu Coil Design X = Direct Expansion Evaporator Coil TXV Included Nom CFM 800 925 980 1225 1425 1625 1750 Hydronic Models 26 = 026 M bthu 36 = 036 M bthu 48 = 048 M bthu 60 = 060 M bthu A G C X C R 0 2 6 A M A A X Coil Cabinet C = Cabinet Encased U = Uncased Model Type R = Refrigerant Coil H = Hydronic Coil 925 1225 1625 1760 Nominal Coil Capacity Refrigerant Models Recommended Airflow CFM 026 M bthu 800-980 036 M bthu 1225 048 M bthu 1425-1625 060 M bthu 1760 Air Coil Type R = Refrigerant H = Hydronic Hydronic Models 060 M bthu Electric Heat 00 = No Electric Heat 05 = 5kW (Available on 22-26 Only) 10 = 10kW (Available on 30-60 Only) 15 = 15kW (Available on 42-60 Only) 20 = 20kW (Available on 60 Only) 1760 Coil Width A = 20.8¨ / 20.0¨ Airflow Configuration Cased = Multi-poise Uncased = Multi-poise Disconnect 0 = No Breaker Installed (5kW and 10 kW heaters) 1 = Breaker Installed (5kW and 10 kW heaters) Series A = Current Motor/Blower 1 = ECM Available Only Vintage A = Current Power Supply 1 = 208-230/60/1 Minor Design Change - not orderable Applications M = Multi-Poise 042-060 Downflow Application Only: Requires Kit ???? System Control Type S = Standard 24 VAC Series A = Current *Select desired options to create specific model number. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-13 Effective 7/1/12 14-1011-28 Split Air Handlers • Heavy gauge galvanized steel with metallic silver powder coat finish • Full interior cabinet insulated with 1/2" foil lined acoustic fiber insulation • Multi-Poise configuration • 2 Piece separatable cabinet for ease of installation • Slide out blower assembly • Full ECM motor • Factory Installed TXV • 1" Filter rack with MERV 4 filter Included • Two stainless steel drain pans • Factory installed internal mounted electric heat • Electro-coated air coil • DX or Hydronic "A" coil option • ARI/ASHRAE/ISO 13256-1 performance certified and UL/ETL safety listed • 10-year parts and 10-year labor allowance Table GEO-14-A — GA Split System Air Handlers Unit Model No. Power Supply Refrigerant Volts/Hz/Phase AGA22R AGA26R AGA30R AGA36R AGA42R AGA48R AGA60R 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Rated Airflow (CFM) Dimensions (in.) H x W x D Shipping Weight (Ibs.) Supply Opening (WxD) Return Opening (DxH) Filter Size Min Circ Amp Max Fuse 800 925 980 1225 1425 1625 1760 57.3x21.0x26.1 57.3x21.0x26.1 57.3x21.0x26.1 57.3x21.0x26.1 57.3x21.0x26.1 57.3x21.0x26.1 57.3x21.0x26.1 215 215 215 215 220 220 220 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 18 x 18 17 x 22 17 x 22 17 x 22 17 x 22 17 x 22 17 x 22 17 x 22 20x24 20x24 20x24 20x24 20x24 20x24 20x24 5 5 5 5 8.8 8.8 8.8 10 10 10 10 15 15 15 Water Inlet/ Outlet Size Min Circ Amp Max Fuse /8 /8 7 /8 7 /8 5 5 8.8 8.8 10 10 15 15 * For models not listed and unit details, please refer to the Geothermal Split System Air Handler Product Data publication. Table GEO-14-B — GA Split System Air Handlers Unit Model No. Power Supply Hydronic Volts/Hz/Phase AGA26H AGA36H AGA48H AGA60H 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Rated Airflow (CFM) Dimensions (in.) H x W x D Shipping Weight (Ibs.) Supply Opening (WxD) Return Opening (DxH) Filter Size 925 1225 1625 1760 57.3x21.0x26.1 57.3x21.0x26.1 57.3x21.0x26.1 57.3x21.0x26.1 220 220 220 220 18 x 18 18 x 18 18 x 18 18 x 18 17 x 22 17 x 22 17 x 22 17 x 22 20x24 20x24 20x24 20x24 7 7 * For models not listed and unit details, please refer to the Geothermal Split System Air Handler Product Data publication. GCX - Coils • "A" Coil Design • Electro-Coated Coil • Copper Tube/ Aluminum Fin Design • Factory Configured for Upflow and Horizontal Left Table GEO-14-C — Common Model Configurations Unit Model No. Cased Coil Unit Model No. Matched Recommended Heat Pump Airflow (CFM) GCX_R026 GCX_R026 GCX_R026 GCX_R060 GCX_R060 GCX_R060 GCX_R060 GCX_R060 GCX_H060 GCX_H060 GCX_H060 GCX_H060 A1GN022 A2GN/GE026 A1GN030 A1GN036 A2GN/GE038 A1GN042 A1GN048 A2GN/GE049 A1GN060 A2GN/GE064 A1GN070 A2GN/GE072 800 925 980 1225 1225 1425 1625 1625 1760 1760 1760 1760 Cased Cabinet Dimensions (in.) H x W x D Supply Connection Width/ Depth 29.1x20.8x26.0 29.1x20.8x26.1 29.1x20.8x26.2 29.1x20.8x26.3 29.1x20.8x26.4 29.1x20.8x26.5 29.1x20.8x26.6 29.1x20.8x26.7 29.1x20.8x26.8 29.1x20.8x26.9 29.1x20.8x26.10 29.1x20.8x26.11 19.0/24.1 19.0/24.1 19.0/24.1 19.0/24.1 19.0/24.1 19.0/24.1 19.0/24.1 19.0/24.1 19.0/24.1 19.0/24.1 19.0/24.1 19.0/24.1 • Field Configurable for Downflow or Horizontal Right • Factory Installed TXV • Sweat Connections • Condensate Drain Pan Included Uncased Hydronic Condensate Shipping Connection Dimensions (in.) Drain H x W x D Weight (Ibs.) In/Out Connection, FTP 20.7x20.0x24.9 20.7x20.0x24.10 20.7x20.0x24.11 20.7x20.0x24.12 20.7x20.0x24.13 20.7x20.0x24.14 20.7x20.0x24.15 20.7x20.0x24.16 20.7x20.0x24.17 20.7x20.0x24.18 20.7x20.0x24.19 20.7x20.0x24.20 100 100 100 100 100 100 100 100 100 100 100 100 N/A N/A N/A N/A N/A N/A N/A N/A 7 /8 7 /8 7 /8 7 /8 /4 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 /4 3 3 Models listed are representative ONLY. Please refer to model nomenclature for product line configuration. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-14 Effective 7/1/12 14-1011-28 Split Air Handlers and Coils Table GEO-15-A — Optional Accessories Model Number 19P578-011 19P578-021 19P578-031 19P578-041 NAHBC 92P521-012 WKA5-103 WKA15-204 59P020B145 Description Vertical Auxiliary Heaters Vertical Auxiliary Heaters Vertical Auxiliary Heaters Vertical Auxiliary Heaters Bottom Flow Conversion Kit Thermal Insulating Blanket Replacement Auxiliary Heat Wiring Kits Replacement Auxiliary Heat Wiring Kits Disposable Filters, 1" MERV4 20x24 Used With NAH022, NAH026, NAH030, NAH036 NAH030, NAH036, NAH042, NAH048, NAH060 NAH042, NAH048, NAH060 NAH060 NAH042, NAH048, NAH060 NAH022, NAH026, NAH030, NAH036, NAH042, NAH048, NAH060 NAH042, NAH048, NAH060 1Internal Mount, Electronic Control Board, Sequenced Operation, 15-20kW include circuit breakers. 22" thickness. 3Wire kit for 5-10 kW auxiliary heaters. 4Wire kit for 15-20 kW auxiliary heaters. 5Minimum order qty. 12. Models listed are representative ONLY. Please refer to model nomenclature for product line configuration. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-15 Effective 7/1/12 14-1011-28 Standard Accessories Table GEO-16-A — Accessories Model NumberDescription GL Flow Centers and Accessories Pre-assembled with pump(s), 3-way valves with flush ports, internal components injected with foam. Horizontal or vertical mounting capability. GL features a Die Cast Brass valve and pump volute, high-impact polystyrene cabinet, GL5PES, and uses GeoLink Connection Kits. FC1-GL 1 Grundfos Pump FC2-GL 2 Grundfos Pumps 2 Brass adapters with P/T plugs for unit connection, 10' reinforced 1" rubber hose for unit to flow center and two 1" GL x 1" hose barb for flow center connection. CK4L-GLI Unit Connection Kit 1" GL x 1" Insert Rubber Hose 1" rubber hose for connection from unit to flow center. RH550 50' of 1" Rubber Hose Geo Storage Tank Use with Hot Water Generator Option or Hydronic Storage. GEO-STORAGE- 80 631/4 x 24 GEO-STORAGE-120 631/4 x 28 Loop Expansion Tank LET 11/4 Socket Fusion, 3/4 Gallon Capacity Anti-Freeze EN2-D 55 Gallon Drum - Environol 2000 Pure EN2-P 5 Gallon Pail - Environol 2000 Pure (minimum order quantity for EN2-P is 5 pails.) Premier IntelliZone 4 Zone Control - with Cabinet and 10' Blower Wiring Harness Multiple level zone calls communicate exact zone load requirements. Controls up to 4 zones with dual capacity compressor (2 with single-speed compressor). Direct control of ECM2 fan motor to match needs of the space. Five fan speeds on line, up to 12 speeds available. Zone sizes as small as 25% of whole house (dual capacity compressor). Individual zone selectable savings or comfort mode. Four upstaging options: normal, quicker, faster or faster with timer for various application scenarios. ZCK4 See Parts and Accessories Catalog for Rectangular and Round Dampers ZTK240 Zone Transformer Kit - 208/240V - 24V ZBHE Zone Blower Harness Extension - 10', Extends ECM2 Harness Earth Loop Flushing System1 High volume, high head, self-priming pump. Quick connect hoses. Heavy duty design. Mounted on a cart. All pipe is schedule 80 polypropolene. LFC-F GL-FP 1" Cam Lever Male Elbow for Flush Port. Adapter Sets 2 pcs. included in each set. 92B025-99 Unit Connector Insulation Kit. GLGH Garden Hose Adapter for Loop Pump Replacement. Service Tool Kit Includes 0-100 PSI Pressure Gauge, Pressure Gauge to PT Port Adapter, Digital Thermometer, Loop Pressurizer, Alcohol Specific Gravity Hygrometer. GEOTHERMAL-STK 99P247A01, LP1, CAMT, 11P538A01, 11P538A02 (Includes DPT160, PG100, GA125) Note: See Parts and Accessories Catalog for Complete Listing of Geothermal Accessory Items. For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. GEO-16 Effective 7/1/12 14-1011-28 American Standard Heating & Air Conditioning 6200 Troup Highway Tyler, Texas 75707 http://www.americanstandardair.com © 2012 American Standard Heating & Air Conditioning All rights reserved 7-12 Pub. No. 14-1011-28 PI ">
Download
Advertisement
Key features
High efficiency
Variable speed
Two-stage
Quiet operation
Reliable performance
Easy to install
Energy efficient
Comfort-R
Frequently asked questions
American Standard offers Platinum, Gold, and Silver series products.
The Platinum series offers the greatest number of features and the best possible performance. The Gold series offers the best blend of performance, features, and value. The Silver series is the most cost-effective way to enjoy comfort and reliability.
American Standard offers single-stage, two-stage, and variable-speed air conditioners.
American Standard offers single-stage, two-stage, and variable-speed heat pumps.
American Standard offers single-stage, two-stage, and variable-speed furnaces.