Cat® 3516

Add to My manuals
4 Pages

advertisement

Cat® 3516 | Manualzz

Cat

®

3516

Diesel Generator Sets

Bore – mm (in)

Stroke – mm (in)

Displacement – L (in 3 )

Compression Ratio

Aspiration

Fuel System

Governor Type

170 (6.69)

190 (7.48)

69 (4210.64)

13.0:1

TA

MUI

Woodward

Image shown may not refl ect actual confi guration

Standby

50 Hz kVA (ekW)

2000 (1600)

Mission Critical

50 Hz kVA (ekW)

2000 (1600)

Prime

50 Hz kVA (ekW)

1825 (1460)

Continuous

50 Hz kVA (ekW)

1600 (1280)

Emissions Performance

Optimized for Low Fuel Consumption

Standard Features

Cat ® Diesel Engine

• Designed and optimized for low fuel consumption

• Reliable performance proven in thousands of applications worldwide

Generator Set Package

• Accepts 100% block load in one step and meets other NFPA 110 loading requirements

• Conforms to ISO 8528-5 G3 load acceptance requirements

• Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing

Alternators

• Superior motor starting capability minimizes need for oversizing generator

• Designed to match performance and output characteristics of Cat diesel engines

Cooling System

• Cooling systems available to operate in ambient temperatures up to 50°C (122°F)

• Tested to ensure proper generator set cooling

EMCP 4 Control Panels

• User-friendly interface and navigation

• Scalable system to meet a wide range of installation requirements

• Expansion modules and site specific programming for specific customer requirements

Warranty

• mission critical ratings

12 months/unlimited hour warranty for prime and continuous ratings

Extended service protection is available to provide extended coverage options

Worldwide Product Support

• Cat dealers have over 1,800 dealer branch stores operating in 200 countries

• Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Financing

• Caterpillar offers an array of financial products to help you succeed through financial service excellence

• Options include loans, finance lease, operating lease, working capital, and revolving line of credit

• Contact your local Cat dealer for availability in your region

LEHE1280-00 Page 1 of 4

3516 Diesel Generator Sets

Electric Power

Optional Equipment

Engine

Air Cleaner

Dual element

Muffler

Industrial grade (10 dB)

Industrial grade (20 dB)

Critical grade (35 dB)

Starting

❑ Standard batteries

❑ Oversized batteries

❑ Standard electric starter(s)

❑ Dual electric starter(s)

❑ Jacket water heater

Alternator

Output voltage

❑ 380V

❑ 400V

❑ 415V

Temperature Rise

(over 40°C ambient)

❑ 150°C

❑ 125°C

❑ 80°C

Winding type

❑ Random wound

❑ Form wound

Excitation

❑ Internal excitation (IE)

❑ Permanent magnet (PM)

Attachments

❑ Anti-condensation heater

❑ Stator and bearing temperature monitoring and protection

Power Termination

Type

❑ Bus bar

❑ Circuit breaker

❑ 2000A ❑ 2500A

❑ 3200A ❑ 4000A

❑ IEC ❑ 3-pole

❑ Electrically operated

Trip Unit

❑ LSI ❑ LSI-G

Control System

Controller

❑ EMCP 4.2

❑ EMCP 4.3

❑ EMCP 4.4

Attachments

❑ Local annunciator module

❑ Remote annunciator module

❑ Expansion I/O module

❑ Remote monitoring software

Charging

❑ Battery charger – 10A

❑ Battery charger – 20A

Vibration Isolators

❑ Rubber

❑ Spring

❑ Seismic rated

Extended Service Options

Terms

❑ 2 year (prime)

❑ 3 year

❑ 5 year

❑ 10 year

Coverage

❑ Silver

❑ Gold

❑ Platinum

❑ Platinum Plus

Ancillary Equipment

❑ Automatic transfer switch

(ATS)

❑ Uninterruptible power supply

(UPS)

❑ Paralleling switchgear

❑ Paralleling controls

Certifications

❑ IBC seismic certification

❑ EU Certification of

Conformance (CE)

❑ EEC Declaration of Conformity

Note: Some options may not be available on all models. Certifi cations may not be available with all model confi gurations. Consult factory for availability.

LEHE1280-00 Page 2 of 4

3516 Diesel Generator Sets

Electric Power

Package Performance

Performance

Frequency

Gen set power rating with fan

Gen set power rating with fan

@ 0.8 power factor

Emissions

Standby

50 Hz

1600 ekW

2000 kVA

Mission Critical

50 Hz

1600 ekW

2000 kVA

Prime

50 Hz

1460 ekW

1825 kVA

Continuous

50 Hz

1280 ekW

1600 kVA

Performance number

Fuel Consumption

100% load with fan – L/hr (gal/hr)

75% load with fan – L/hr (gal/hr)

50% load with fan – L/hr (gal/hr)

25% load with fan – L/hr (gal/hr)

Cooling System

Radiator air flow restriction (system)

– kPa (in. water)

Low Fuel

DM8366-03

420.9

(111.2)

317.5

(83.9)

226.0

132.1

(59.7)

(34.9)

0.12

(0.48)

Low Fuel

EM0610-01

0.12

(0.48)

Low Fuel

DM8367-02

420.9

(111.2) 382.8

(101.1)

317.5

(83.9) 292.1

(77.2)

226.0

132.1

(59.7)

(34.9)

209.8

123.4

(55.4)

(32.6)

0.12

(0.48)

Low Fuel

DM8368-04

337.2

260.4

188.3

112.6

0.12

(89.1)

(68.8)

(49.7)

(29.7)

(0.48)

Radiator air flow – m 3 /min (cfm)

Engine coolant capacity – L (gal)

Radiator coolant capacity – L (gal)

CO mg/Nm 3 (g/hp-h)

HC mg/Nm 3 (g/hp-h)

PM mg/Nm 3 (g/hp-h)

1543 (54490) 1543 (54490)

233.0

(61.6) 233.0

(61.6)

165.0

398

(43.6)

(105.2)

165.0

398

(43.6)

(105.2)

1543 (54490) 1543 (54490)

233.0

(61.6) 233.0

(61.6)

165.0

398

(43.6)

(105.2)

165.0

398

(43.6)

(105.2) Total coolant capacity – L (gal)

Inlet Air

Combustion air inlet flow rate – m 3 /min (cfm)

Exhaust System

Exhaust stack gas temperature – °C (°F)

Exhaust gas flow rate – m 3 /min (cfm)

Heat rejection to aftercooler – kW (Btu/min)

Heat rejection to atmosphere from engine – kW (Btu/min)

Heat rejection from alternator – kW (Btu/min)

Emissions (Nominal)

NOx mg/Nm 3 (g/hp-h)

CO mg/Nm 3 (g/hp-h)

HC mg/Nm 3 (g/hp-h)

PM mg/Nm 3 (g/hp-h)

Emissions (Potential Site Variation)

NOx mg/Nm 3 (g/hp-h)

127.7

(4509.4) 127.7

(4509.4) 118.4

(4179.2) 107.1

(3781.9)

498.5

(929.2) 498.5

(929.2) 488.2

(910.7) 478.2

(892.8)

334.0 (11795.4) 334.0 (11795.4) 305.1 (10773.9) 272.3

(9616.3)

Exhaust system backpressure

(maximum allowable) – kPa (in. water)

Heat Rejection

Heat rejection to jacket water – kW (Btu/min)

6.7

(27.0) 6.7

(27.0)

1055 (59999) 1055 (59999)

Heat rejection to exhaust (total) – kW (Btu/min) 1532 (87130) 1532 (87130)

232

166

77

(13191)

(9448)

(4383)

232

166

77

(13191)

(9448)

(4383)

6.7

(27.0) 6.7

(27.0)

953 (54169) 832 (47319)

1386 (78814) 1222 (69503)

187 (10611) 136 (7750)

158

69

(8978)

(3913)

146

58

(8285)

(3273)

7207.2 (13.59) 7207.2 (13.59) 7690.3

(14.43) 8115.8

(15.24)

350.6

(0.73 ) 350.6

(0.73 ) 324.3

(0.67) 354.8

(0.73)

89.3

(0.21)

89.3

(0.21)

82.0

(0.20)

74.6

(0.18)

8648.7

(16.31) 8648.7

(16.31) 9228.4

(17.31) 9739.0

(18.28)

631.2

(1.31) 631.2

(1.31) 583.8

(1.21) 638.7

(1.32)

118.8

(0.29)

118.8

(0.29)

109.0

(0.26)

99.3

(0.24)

LEHE1280-00 Page 3 of 4

3516 Diesel Generator Sets

Electric Power

Weights and Dimensions

C

A B

Dim “A” mm (in)

5919 (232.9)

Dim “B” mm (in)

2286 (90.0)

Dim “C” mm (in)

2367 (93.2)

Dry Weight kg (lb)

16 375 (33,900)

Note: For reference only. Do not use for installation design. Contact your local Cat dealer for precise weights and dimensions.

Ratings Defi nitions

Standby

Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby power rating. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year.

Mission Critical

Output available with varying load for the duration of the interruption of the normal source power. Average power output is 85% of the mission critical power rating.

Typical peak demand up to 100% of rated power for up to 5% of the operating time. Typical operation is

200 hours per year, with maximum expected usage of

500 hours per year.

Prime

Output available with varying load for an unlimited time.

Average power output is 70% of the prime power rating.

Typical peak demand is 100% of prime rated ekW with 10% overload capability for emergency use for a maximum of 1 hour in 12. Overload operation cannot exceed 25 hours per year.

Continuous

Output available with non-varying load for an unlimited time. Average power output is 70-100% of the continuous power rating. Typical peak demand is 100% of continuous rated kW for 100% of the operating hours.

3516 PGEI

LEHE1280-00 (5-17)

Applicable Codes and Standards

AS1359, CSA C22.2 No100-04, UL142, UL489, UL869,

UL2200, NFPA37, NFPA70, NFPA99, NFPA110, IBC,

IEC60034-1, ISO3046, ISO8528, NEMA MG1-22,

NEMA MG1-33, 2014/35/EU, 2006/42/EC, 2014/30/EU.

Note: Codes may not be available in all model configurations. Please consult your local Cat dealer for availability.

Data Center Applications

Tier III/Tier IV compliant per Uptime Institute requirements. ANSI/TIA-942 compliant for Rated-1 through Rated-4 data centers.

Fuel Rates

Fuel rates are based on fuel oil of 35º API [16°C (60ºF)] gravity having an LHV of 42,780 kJ/kg (18,390 Btu/lb) when used at 29ºC (85ºF) and weighing 838.9 g/liter

(7.001 lbs/U.S. gal.) www.cat.com/electricpower

©2017 Caterpillar

All rights reserved.

Materials and specifications are subject to change without notice.

The International System of Units (SI) is used in this publication.

CAT, CATERPILLAR, their respective logos, “Caterpillar Yellow”, the

“Power Edge” trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.

advertisement

advertisement