![](http://s1.manualzz.com/store/data/045314017_1-47b863b4ada901fbbabe2fadfcf44d96-128x128.png)
advertisement
![Cat® 3516 | Manualzz Cat® 3516 | Manualzz](http://s1.manualzz.com/store/data/045314017_1-47b863b4ada901fbbabe2fadfcf44d96-360x466.png)
Cat
®
3516
Diesel Generator Sets
Bore – mm (in)
Stroke – mm (in)
Displacement – L (in 3 )
Compression Ratio
Aspiration
Fuel System
Governor Type
170 (6.69)
190 (7.48)
69 (4210.64)
13.0:1
TA
MUI
Woodward
Image shown may not refl ect actual confi guration
Standby
50 Hz kVA (ekW)
2000 (1600)
Mission Critical
50 Hz kVA (ekW)
2000 (1600)
Prime
50 Hz kVA (ekW)
1825 (1460)
Continuous
50 Hz kVA (ekW)
1600 (1280)
Emissions Performance
Optimized for Low Fuel Consumption
Standard Features
Cat ® Diesel Engine
• Designed and optimized for low fuel consumption
• Reliable performance proven in thousands of applications worldwide
Generator Set Package
• Accepts 100% block load in one step and meets other NFPA 110 loading requirements
• Conforms to ISO 8528-5 G3 load acceptance requirements
• Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
Alternators
• Superior motor starting capability minimizes need for oversizing generator
• Designed to match performance and output characteristics of Cat diesel engines
Cooling System
• Cooling systems available to operate in ambient temperatures up to 50°C (122°F)
• Tested to ensure proper generator set cooling
EMCP 4 Control Panels
• User-friendly interface and navigation
• Scalable system to meet a wide range of installation requirements
• Expansion modules and site specific programming for specific customer requirements
Warranty
• mission critical ratings
12 months/unlimited hour warranty for prime and continuous ratings
Extended service protection is available to provide extended coverage options
Worldwide Product Support
• Cat dealers have over 1,800 dealer branch stores operating in 200 countries
• Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Financing
• Caterpillar offers an array of financial products to help you succeed through financial service excellence
• Options include loans, finance lease, operating lease, working capital, and revolving line of credit
• Contact your local Cat dealer for availability in your region
LEHE1280-00 Page 1 of 4
3516 Diesel Generator Sets
Electric Power
Optional Equipment
Engine
Air Cleaner
❑ Dual element
Muffler
❑ Industrial grade (10 dB)
❑ Industrial grade (20 dB)
❑ Critical grade (35 dB)
Starting
❑ Standard batteries
❑ Oversized batteries
❑ Standard electric starter(s)
❑ Dual electric starter(s)
❑ Jacket water heater
Alternator
Output voltage
❑ 380V
❑ 400V
❑ 415V
Temperature Rise
(over 40°C ambient)
❑ 150°C
❑ 125°C
❑ 80°C
Winding type
❑ Random wound
❑ Form wound
Excitation
❑ Internal excitation (IE)
❑ Permanent magnet (PM)
Attachments
❑ Anti-condensation heater
❑ Stator and bearing temperature monitoring and protection
Power Termination
Type
❑ Bus bar
❑ Circuit breaker
❑ 2000A ❑ 2500A
❑ 3200A ❑ 4000A
❑ IEC ❑ 3-pole
❑ Electrically operated
Trip Unit
❑ LSI ❑ LSI-G
Control System
Controller
❑ EMCP 4.2
❑ EMCP 4.3
❑ EMCP 4.4
Attachments
❑ Local annunciator module
❑ Remote annunciator module
❑ Expansion I/O module
❑ Remote monitoring software
Charging
❑ Battery charger – 10A
❑ Battery charger – 20A
Vibration Isolators
❑ Rubber
❑ Spring
❑ Seismic rated
Extended Service Options
Terms
❑ 2 year (prime)
❑ 3 year
❑ 5 year
❑ 10 year
Coverage
❑ Silver
❑ Gold
❑ Platinum
❑ Platinum Plus
Ancillary Equipment
❑ Automatic transfer switch
(ATS)
❑ Uninterruptible power supply
(UPS)
❑ Paralleling switchgear
❑ Paralleling controls
Certifications
❑ IBC seismic certification
❑ EU Certification of
Conformance (CE)
❑ EEC Declaration of Conformity
Note: Some options may not be available on all models. Certifi cations may not be available with all model confi gurations. Consult factory for availability.
LEHE1280-00 Page 2 of 4
3516 Diesel Generator Sets
Electric Power
Package Performance
Performance
Frequency
Gen set power rating with fan
Gen set power rating with fan
@ 0.8 power factor
Emissions
Standby
50 Hz
1600 ekW
2000 kVA
Mission Critical
50 Hz
1600 ekW
2000 kVA
Prime
50 Hz
1460 ekW
1825 kVA
Continuous
50 Hz
1280 ekW
1600 kVA
Performance number
Fuel Consumption
100% load with fan – L/hr (gal/hr)
75% load with fan – L/hr (gal/hr)
50% load with fan – L/hr (gal/hr)
25% load with fan – L/hr (gal/hr)
Cooling System
Radiator air flow restriction (system)
– kPa (in. water)
Low Fuel
DM8366-03
420.9
(111.2)
317.5
(83.9)
226.0
132.1
(59.7)
(34.9)
0.12
(0.48)
Low Fuel
EM0610-01
0.12
(0.48)
Low Fuel
DM8367-02
420.9
(111.2) 382.8
(101.1)
317.5
(83.9) 292.1
(77.2)
226.0
132.1
(59.7)
(34.9)
209.8
123.4
(55.4)
(32.6)
0.12
(0.48)
Low Fuel
DM8368-04
337.2
260.4
188.3
112.6
0.12
(89.1)
(68.8)
(49.7)
(29.7)
(0.48)
Radiator air flow – m 3 /min (cfm)
Engine coolant capacity – L (gal)
Radiator coolant capacity – L (gal)
CO mg/Nm 3 (g/hp-h)
HC mg/Nm 3 (g/hp-h)
PM mg/Nm 3 (g/hp-h)
1543 (54490) 1543 (54490)
233.0
(61.6) 233.0
(61.6)
165.0
398
(43.6)
(105.2)
165.0
398
(43.6)
(105.2)
1543 (54490) 1543 (54490)
233.0
(61.6) 233.0
(61.6)
165.0
398
(43.6)
(105.2)
165.0
398
(43.6)
(105.2) Total coolant capacity – L (gal)
Inlet Air
Combustion air inlet flow rate – m 3 /min (cfm)
Exhaust System
Exhaust stack gas temperature – °C (°F)
Exhaust gas flow rate – m 3 /min (cfm)
Heat rejection to aftercooler – kW (Btu/min)
Heat rejection to atmosphere from engine – kW (Btu/min)
Heat rejection from alternator – kW (Btu/min)
Emissions (Nominal)
NOx mg/Nm 3 (g/hp-h)
CO mg/Nm 3 (g/hp-h)
HC mg/Nm 3 (g/hp-h)
PM mg/Nm 3 (g/hp-h)
Emissions (Potential Site Variation)
NOx mg/Nm 3 (g/hp-h)
127.7
(4509.4) 127.7
(4509.4) 118.4
(4179.2) 107.1
(3781.9)
498.5
(929.2) 498.5
(929.2) 488.2
(910.7) 478.2
(892.8)
334.0 (11795.4) 334.0 (11795.4) 305.1 (10773.9) 272.3
(9616.3)
Exhaust system backpressure
(maximum allowable) – kPa (in. water)
Heat Rejection
Heat rejection to jacket water – kW (Btu/min)
6.7
(27.0) 6.7
(27.0)
1055 (59999) 1055 (59999)
Heat rejection to exhaust (total) – kW (Btu/min) 1532 (87130) 1532 (87130)
232
166
77
(13191)
(9448)
(4383)
232
166
77
(13191)
(9448)
(4383)
6.7
(27.0) 6.7
(27.0)
953 (54169) 832 (47319)
1386 (78814) 1222 (69503)
187 (10611) 136 (7750)
158
69
(8978)
(3913)
146
58
(8285)
(3273)
7207.2 (13.59) 7207.2 (13.59) 7690.3
(14.43) 8115.8
(15.24)
350.6
(0.73 ) 350.6
(0.73 ) 324.3
(0.67) 354.8
(0.73)
89.3
—
(0.21)
—
89.3
—
(0.21)
—
82.0
—
(0.20)
—
74.6
—
(0.18)
—
8648.7
(16.31) 8648.7
(16.31) 9228.4
(17.31) 9739.0
(18.28)
631.2
(1.31) 631.2
(1.31) 583.8
(1.21) 638.7
(1.32)
118.8
—
(0.29)
—
118.8
—
(0.29)
—
109.0
—
(0.26)
—
99.3
—
(0.24)
—
LEHE1280-00 Page 3 of 4
3516 Diesel Generator Sets
Electric Power
Weights and Dimensions
C
A B
Dim “A” mm (in)
5919 (232.9)
Dim “B” mm (in)
2286 (90.0)
Dim “C” mm (in)
2367 (93.2)
Dry Weight kg (lb)
16 375 (33,900)
Note: For reference only. Do not use for installation design. Contact your local Cat dealer for precise weights and dimensions.
Ratings Defi nitions
Standby
Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby power rating. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year.
Mission Critical
Output available with varying load for the duration of the interruption of the normal source power. Average power output is 85% of the mission critical power rating.
Typical peak demand up to 100% of rated power for up to 5% of the operating time. Typical operation is
200 hours per year, with maximum expected usage of
500 hours per year.
Prime
Output available with varying load for an unlimited time.
Average power output is 70% of the prime power rating.
Typical peak demand is 100% of prime rated ekW with 10% overload capability for emergency use for a maximum of 1 hour in 12. Overload operation cannot exceed 25 hours per year.
Continuous
Output available with non-varying load for an unlimited time. Average power output is 70-100% of the continuous power rating. Typical peak demand is 100% of continuous rated kW for 100% of the operating hours.
3516 PGEI
LEHE1280-00 (5-17)
Applicable Codes and Standards
AS1359, CSA C22.2 No100-04, UL142, UL489, UL869,
UL2200, NFPA37, NFPA70, NFPA99, NFPA110, IBC,
IEC60034-1, ISO3046, ISO8528, NEMA MG1-22,
NEMA MG1-33, 2014/35/EU, 2006/42/EC, 2014/30/EU.
Note: Codes may not be available in all model configurations. Please consult your local Cat dealer for availability.
Data Center Applications
Tier III/Tier IV compliant per Uptime Institute requirements. ANSI/TIA-942 compliant for Rated-1 through Rated-4 data centers.
Fuel Rates
Fuel rates are based on fuel oil of 35º API [16°C (60ºF)] gravity having an LHV of 42,780 kJ/kg (18,390 Btu/lb) when used at 29ºC (85ºF) and weighing 838.9 g/liter
(7.001 lbs/U.S. gal.) www.cat.com/electricpower
©2017 Caterpillar
All rights reserved.
Materials and specifications are subject to change without notice.
The International System of Units (SI) is used in this publication.
CAT, CATERPILLAR, their respective logos, “Caterpillar Yellow”, the
“Power Edge” trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
advertisement
advertisement