Bedienungsanleitung
Regenwächter
NW/O
1 / 13 71030/11/0315
Inhaltsverzeichnis
1 Ausführung ................................................................................................................................... 3
2 Anwendung .................................................................................................................................. 3
3 Arbeitsweise ................................................................................................................................. 3
4 Installation .................................................................................................................................... 4
4.1 Mechanische Montage .......................................................................................................... 4
4.2 Elektrische Montage .............................................................................................................. 4
4.2.1 Anschlussbelegung und Niederschlagsstatus ................................................................ 5
5 Inbetriebnahme ............................................................................................................................ 5
6 Wartung ....................................................................................................................................... 5
7 Technische Daten ........................................................................................................................ 5
8 Maßbild ........................................................................................................................................ 6
2 / 13 71030/11/0315
1 Ausführung
Bestell - Nr. Messwert Ausgang
NW/O Niederschlagsstatus
(ja / nein)
Halbleiter-Relais,
Typ: Wechsler
Lieferumfang:
- Regenwächter
- Befestigungssatz (siehe Ausführung)
- Bedienungsanleitung
2 Anwendung
Betriebs- spannung
11…28 V AC oder
10…32 V DC
Ausstattung
- 3 m Kabel, 5 pol.
- Befestigungssatz
Der Regenwächter dient als Signalgeber zur Ermittlung von Niederschlagsbeginn und -ende. Er wird als Zustandsmelder oder Signalgeber zur Steuerung für nachgeschaltete Sicherheitseinrichtungen (Steuerungen) zum Schutz für Fenster, Lüftungsklappen, Jalousien, Markisen etc. eingesetzt. Die Sensorfläche ist ein Kondensator auf einer mit Glas beschichteten Keramik. Durch die Glaspassivierung ist der Regenwächter sehr umweltbeständig, robust, langzeitstabil und resistent gegenüber aggressiven Medien.
3 Arbeitsweise
Niederschlag der auf den Regenwächter trifft und dabei die Sensorfläche benetzt, verändert die
Kapazität der Fläche. Diese Änderung löst ein Schaltsignal aus, d. h. eine benetzte Sensorfläche signalisiert den Niederschlagstatus „ja“.
Zum Schutz vor Betauung und Vereisung wird die Sensorfläche auf eine Übertemperatur von ca. 2 K beheizt.
Bei benetzter Sensorfläche wird diese auf ca. 10 K über der Umgebungstemperatur geregelt, dadurch erfolgt eine schnellere Trocknung. Nach der Trocknung schaltet das Gerät auf den
Niederschlagstatus „nein“.
Definition zum Niederschlagsstatus / Ausgang:
Niederschlag „ja“
Niederschlag „nein“
Stromausfall (Sensor „aus“)
= Kontakt 3-4 offen
= Kontakt 3-4 geschlossen
= Kontakt 3-4 offen
Bei fehlender oder unterbrochener Betriebsspannung (Sensor „aus“) wird Niederschlag „ja“ signalisiert, dadurch ist auch bei diesem Zustand ein Objektschutz vorhanden.
3 / 13 71030/11/0315
4 Installation
Achtung:
Die elektrischen Arbeiten sind vom Fachpersonal auszuführen.
4.1 Mechanische Montage
Das Gerät ist an repräsentativer Stelle möglichst windgeschützt zu montieren. Achten sie darauf, dass der Niederschlag die Sensorfläche ungestört erreichen kann.
Maße, siehe Kapitel 8.
Gerät ohne Befestigungssatz
Die Montage ist an einer ebenen senkrechten oder waagerechten Fläche möglich.
Gerät mit Befestigungssatz
Für die Montage an einem Mastrohr
(Ø 35-50mm).
4.2 Elektrische Montage
Die elektrische Versorgung kann mit Wechsel- oder Gleichspannung erfolgen. Das Gerät ist verpolungssicher. Der Ausgang ist ein potentialgetrenntes elektronisches Relais. Der Anschluss erfolgt über ein fest angeschlossenes Kabel, hierzu siehe Anschlussschaltbild Kapitel 4.2.1.
4 / 13 71030/11/0315
4.2.1 Anschlussbelegung und Niederschlagsstatus
Kontakt 1-2 Kontakt 3-4 Kontakt 4-5
Sensorfläche benetzt
Sensorfläche trocken
Sensorfläche benetzt oder trocken ja geschlossen
Abbildungszustand: - Gerät stromlos oder
- Sensorfläche benetzt offen
Heizung
Heating
Elektronik
Electronic
Kabel / Cable
Niederschlag
Rain nein / no ja / yes
1 2
11 ... 28 V AC
11 ... 32 V DC
Max. 0,75 A
Versorgung
Power Supply
3 4 5
26V AC / 36V DC
Max. 0,5 A
Halbleiter - Relais
Schaltausgang
Semi - conductor Relay
Switching output
5 Inbetriebnahme
Nachdem der elektrische Anschluss hergestellt wurde, kann die Betriebsspannung eingeschaltet werden.
6 Wartung
Das Gerät ist wartungsfrei.
Reinigen:
Abhängig vom Einsatzort und der damit verbundenen Verschmutzungsart und
Verschmutzungsstärke empfehlen wir, die Sensorfläche des Geräts in entsprechenden
Zeitabständen zu prüfen und ggf. zu reinigen.
Für die Reinigung sollte ein angefeuchtetes Tuch, ohne chemische Reinigungsmittel, verwendet werden.
Messwert
Signal- Ausgang
Niederschlag (ja / nein)
Halbleiter-Relais, potentialfrei / elektrisch isoliert / galvanisch getrennt
Relais- Schaltspannung max. 26 VAC / 36 VDC, max. 0,5 A (cos φ > 0.9), 0,2 A (cos φ = 0.4)
Einschaltverzögerung
Betriebsspannung
< 0.5 s Signalausgang
15 s Heizung
11...28 VAC oder 11...32 VDC (max. 0,75A)
Verpolungsschutz
Stromaufnahme Heizung aus:
< 15 mA
5 / 13 71030/11/0315
Heizung an: max. 0,35 A (@ 11...12 VAC Versorgung) max. 0,75 A (@ 12...27 VAC Versorgung) max. 0,3 A (@ 27...32 VAC Versorgung)
Sensorfläche
Empfindlichkeit
18 cm² ca. 0,2 mm/h
Umgebungstemperatur -30...+60°C
Schutzart
Abmessung
Gewicht
Material
IP 66 nach DIN 40050
Siehe Maßbild (Kapitel 8)
160 g mit Befestigungssatz
100 g ohne Befestigungssatz
Gehäuse: Polycarbonat (PC), UV-stabilisiert, weiß (RAL 9010)
Sensor: Keramik (Aluminiumoxid AL
2
O
3
) mit Glasbeschichtung
Befestigungssatz: Niro 1.4301
Anschlussart Kabel, fest angeschlossen, Typ: LiYY 5 x 0,14mm², 3m lang
8 Maßbild
Abbildung 1: Regenwächter mit Befestigungssatz
6 / 13 71030/11/0315
Instruction for use
Rain Sensor
NW/O
7 / 13 71030/11/0315
Contents
9 Model ........................................................................................................................................... 9
10 Application ................................................................................................................................ 9
11 Mode of Operation .................................................................................................................... 9
12 Installation .............................................................................................................................. 10
12.1 Mechanical Mounting .......................................................................................................... 10
12.2 Electrical Mounting .............................................................................................................. 10
12.2.1 Pin Assignment and Precipitation Status ................................................................... 11
13 Taking into Operation ............................................................................................................. 11
14 Maintenance ........................................................................................................................... 11
15 Technical Data ........................................................................................................................ 11
16 Dimension diagram ................................................................................................................. 13
8 / 13 71030/11/0315
1 Model
Article - No. Measuring value Output
NW/O Precipitation status
(yes/no)
Semiconductor relay:
Type: Changeover
Scope of delivery:
- rain monitor
- fixing kit (see Model)
- operating instructions
2 Application
Operating-
Voltage
11…28 V AC or
10…32 V DC
Configuration
- 3 m cable, 5 pol.
- fixing kit
The rain monitor is designed to act as a sensor detecting the start and end of precipitation. It is used as a status indicator or sensor for controlling downstream safety devices (control units) protecting windows, ventilation flaps, sunblinds, awnings, etc. The sensor area takes the form of a capacitor on glass-coated ceramic. Glass passivation ensures that the rain monitor is extremely environment-resistant as well as robust while offering good long-term stability and resistance to aggressive media.
3 Mode of Operation
Whenever precipitation strikes the rain monitor and wets the sensor surface, this changes the capacitance of the surface, so triggering a switching signal, i.e. wetting of the sensor surface signals the precipitation status "yes".
To protect the sensor surface from bedewing and icing-up, it is heated to an overtemperature of approx. 2 K.
When the sensor surface is wetted, it is adjusted to approx. 10 K above the ambient temperature, so ensuring fast faster drying. Once it has dried, the device switches to the precipitation status "no".
Definition for precipitation status / output:
Precipitation “yes”
Precipitation “no”
Power failure (sensor “off”)
= contact 3-4 open
= contact 3-4 closed
= contact 3-4 open
In case of interrupted or missing operating voltage (sensor “off”) precipitation “yes” is signalized; thus, even in this state the object to be protected is safeguarded.
9 / 13 71030/11/0315
4 Installation
Please Note:
The electrical connection is to be carried out by experts only.
4.1 Mechanical Mounting
The device should be installed at a location that will result in representative readings and protected from the wind as far as possible. During installation make sure that precipitation can strike the sensor surface unimpeded. For dimensions, see section 8.
Instrument without fixing kit
Mounting is possible at an even vertical or horizontal surface.
Instrument with fixing kit
Mounting can be carried out at the end of a mast tube (Ø 35-50mm).
4.2 Electrical Mounting
Either AC or DC can be used as the power supply, with protection from polarity reversal. The output is an isolated electronic relay. A non-detachable cable is used for connection: see connecting diagram, section 4.2.1.
10 / 13 71030/11/0315
4.2.1 Pin Assignment and Precipitation Status
Sensor surface wet
Sensor surface dry
1-2
Yes
Yes
Contact 3-4 open closed
Contact 4-5 closed open
Sensor surface wet or dry no open closed
Figure state: - instrument power-off or
- sensor surface wet
Heizung
Heating
Elektronik
Electronic
Kabel / Cable
Niederschlag
Rain nein / no ja / yes
1 2
11 ... 28 V AC
11 ... 32 V DC
Max. 0,75 A
Versorgung
Power Supply
3 4 5
26V AC / 36V DC
Max. 0,5 A
Halbleiter - Relais
Schaltausgang
Semi - conductor Relay
Switching output
5 Taking into Operation
The operating voltage can be switched on once the electrical connection has been made.
6 Maintenance
The device is maintenance free.
Cleaning:
Depending on the installation location and the associated type/degree of soiling occurring there, we recommend checking the sensor surface of the device at suitable intervals and cleaning it as required.
For cleaning a damp cloth without chemical cleaning agents should be used.
Measuring value
Signal output
Precipitation (yes / no)
Semiconductor relay, Potential-free / electrically isolated / metallically separated
Relay- contact voltage Max. 26 V AC / 36 V DC,
Max. 0.5 A (cos φ > 0.9), 0.2A (cos φ = 0.4)
Switch-on delay < 0.5 s Signal- Output
15 s Heating
11 / 13 71030/11/0315
Operating voltage 11...28 VAC or 11...32 VDC (max. 0,75A)
Protected against polarity reversal
Current consumption Heating off:
< 12 mA
Heating on: max. 0.35 A (@ 11...12 VAC operating voltage) max. 0.75 A (@ 12...27 VAC operating voltage) max. 0.3 A (@ 27...32 VAC operating voltage)
Sensor area
Sensitivity
18 cm²
Approx. 0.2 mm/h
Ambient temperature -30...+60°C
Protection
Dimension
Weight
IP 66 acc. to DIN 40050
See dimension diagram (section 9)
160 g with fixing kit
100 g without fixing kit
Material
Connection
Housing: Polycarbonate (PC), UV-stabilised, white (RAL 9010)
Sensor: Ceramic (aluminum oxide AL
2
O
3
), glass-coated
Fixing kit: Stainless steel 1.4301
Cable, non-detachable, type: LiYY 5 x 0.14mm², 3m long
12 / 13 71030/11/0315
Figure 1: Rain monitor with fixing kit
© Copyright: FuehlerSysteme eNET International GmbH
Address
FuehlerSysteme eNET International GmbH
Phone
+49 911 37322-0
Fax
+49 911 37322-111
E-Mail & Web [email protected]
www.fuehlersysteme.de
Technical Support
+49 1805 858511
*
* 14 ct/min. from german network -
max. 42 ct/min. from german mobile phone
- Subject to technical modifications -
13 / 13 71030/11/0315