Juniper M320 Hardware Guide
โฆษณา
โฆษณา
M320 Multiservice Edge Router Hardware Guide
Modified: 2015-05-20
Copyright © 2015, Juniper Networks, Inc.
Juniper Networks, Inc.
1133 Innovation Way
Sunnyvale, California 94089
USA
408-745-2000 www.juniper.net
Copyright © 2015, Juniper Networks, Inc. All rights reserved.
Juniper Networks, Junos, Steel-Belted Radius, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc. in the United
States and other countries. The Juniper Networks Logo, the Junos logo, and JunosE are trademarks of Juniper Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice.
M320 Multiservice Edge Router Hardware Guide
Copyright © 2015, Juniper Networks, Inc.
All rights reserved.
The information in this document is current as of the date on the title page.
YEAR 2000 NOTICE
Juniper Networks hardware and software products are Year 2000 compliant. Junos OS has no known time-related limitations through the year 2038. However, the NTP application is known to have some difficulty in the year 2036.
END USER LICENSE AGREEMENT
The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at http://www.juniper.net/support/eula.html
. By downloading, installing or using such software, you agree to the terms and conditions of that EULA.
ii Copyright © 2015, Juniper Networks, Inc.
Table of Contents
Part 1
Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . . xxvi
Overview
M320 Cable Management System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
M320 Connector Interface Panel (CIP) Description . . . . . . . . . . . . . . . . . . . . . . . . 13
M320 Craft Interface Alarm LEDs and ACO/LT Button . . . . . . . . . . . . . . . . . . . . . . 16
M320 Craft Interface LED Display and Navigation Buttons . . . . . . . . . . . . . . . . . . 16
M320 Craft Interface FPC LEDs and Online/Offline Buttons . . . . . . . . . . . . . . . . . 18
Cooling System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 21
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . 23
Copyright © 2015, Juniper Networks, Inc.
iii
M320 Multiservice Edge Router Hardware Guide
M320 RE-A-1800 Routing Engine Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
TX Matrix Plus (with 3D SIBs) Routing Engines . . . . . . . . . . . . . . . . . . . . . . . 44
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
M320 Flexible PIC Concentrator (FPC) Description . . . . . . . . . . . . . . . . . . . . . . . . 49
PIC/FPC Compatibility (Type 1 FPCs and Type 1 PICs) . . . . . . . . . . . . . . . . . . 67
PIC/FPC Compatibility (Type 2 FPCs and Type 2 PICs) . . . . . . . . . . . . . . . . . 70
PIC/FPC Compatibility (Type 3 FPCs and Type 3 PICs) . . . . . . . . . . . . . . . . . . 71
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 73
iv Copyright © 2015, Juniper Networks, Inc.
Table of Contents
Part 2
Components Powered by Each Power Supply Slot . . . . . . . . . . . . . . . . . . . . . 75
DC Power Supply Load Sharing and Fault Tolerance . . . . . . . . . . . . . . . . . . . 76
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . 79
M320 Performance for Different SIB Configurations . . . . . . . . . . . . . . . . . . . . . . . 80
Site Planning, Preparation, and Specifications
M320 Cabinet Size and Clearance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . 88
M320 Chassis Grounding Cable and Lug Specifications . . . . . . . . . . . . . . . . . . . . 94
Site Electrical Wiring Guidelines for Juniper Networks Devices . . . . . . . . . . . . . . . 95
M320 RJ-48 Connector Pinouts for the Control Board External Clock Inputs . . . 98
DC Power System Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Nonisolated DC Power Supply Electrical Specifications . . . . . . . . . . . . . . . . 106
Isolated DC Power Supply Electrical Specifications . . . . . . . . . . . . . . . . . . . 106
Network Cable and Transceiver Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion . . . . . 111
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable . . . . . . . . . . . . 111
Attenuation and Dispersion in Fiber-Optic Cable . . . . . . . . . . . . . . . . . . . . . . 111
Calculating Power Budget and Power Margin for Fiber-Optic Cables . . . . . . . . . . 112
Calculating Power Budget for Fiber-Optic Cable . . . . . . . . . . . . . . . . . . . . . . 112
Calculating Power Margin for Fiber-Optic Cable . . . . . . . . . . . . . . . . . . . . . . . 113
Copyright © 2015, Juniper Networks, Inc.
v
M320 Multiservice Edge Router Hardware Guide vi
Part 3
Management Cable and Transceiver Specifications and Pinouts . . . . . . . . 115
M320 Routing Engine Interface Cable and Wire Specifications . . . . . . . . . . . . . . . 115
M320 RJ-45 Connector Pinouts for the Routing Engine ETHERNET Port . . . . . . . 116
M320 DB-9 Connector Pinouts for the Routing Engine AUX and CONSOLE
Initial Installation and Configuration
Tools and Parts Required to Unpack the M320 Router . . . . . . . . . . . . . . . . . . . . . 123
Installing the M320 Mounting Hardware for a Four-Post Rack or Cabinet . . . . . . 127
Installing Cage Nuts (If Needed) for M320 Four-Post Racks or Cabinets . . . 127
Installing the Large Mounting Shelf for M320 Four-Post Racks or
Installing the Small Mounting Shelf for M320 Four-Post Racks or
Removing the Adjustable Center-Mounting Brackets for M320 Four-Post
Installing the M320 Mounting Hardware for Open-Frame Racks . . . . . . . . . . . . . 130
Installing Cage Nuts (If Needed) for M320 Open Frame Racks . . . . . . . . . . . 131
Installing the Large Mounting Shelf for the M320 Open-Frame Racks . . . . . 132
Installing the Small Mounting Shelf for the M320 Open-Frame Racks . . . . . 132
Moving the Adjustable Center-Mounting Brackets for M320 Open-Frame
Installing the M320 With a Mechanical Lift . . . . . . . . . . . . . . . . . . . . . . . . . . 135
Overview of Installing the M320 Chassis Using a Mechanical Lift . . . . . . . . . . . . 135
Tools Required to Install the M320 Chassis Using a Mechanical Lift . . . . . . . . . . 136
Installing the M320 Chassis Using a Mechanical Lift . . . . . . . . . . . . . . . . . . . . . . 136
Attaching the Installation Handle to the M320 Chassis . . . . . . . . . . . . . . . . 136
Mounting the M320 Chassis Using a Mechanical Lift . . . . . . . . . . . . . . . . . . 138
Removing the M320 Installation Handle and Reinstalling the Power
Installing the M320 Without a Mechanical Lift . . . . . . . . . . . . . . . . . . . . . . . 143
Tools and Parts Required to Install the M320 Chassis Without a Mechanical
Removing M320 Components from the Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . 143
Removing the M320 Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Copyright © 2015, Juniper Networks, Inc.
Table of Contents
Part 4
Removing the M320 Cable Management System . . . . . . . . . . . . . . . . . . . . . 148
Removing the M320 Front Fan Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Reinstalling the M320 Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
Reinstalling the M320 Cable Management System . . . . . . . . . . . . . . . . . . . . 159
Tools and Parts Required to Ground the M320 Router . . . . . . . . . . . . . . . . . . . . . 161
Connecting the M320 Router Grounding Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
Connecting the M320 to External Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Tools and Parts Required for M320 Router Connections . . . . . . . . . . . . . . . . . . . 163
Overview of Connecting the M320 Router to Management and Alarm
Connecting the M320 Router to a Management Console or Auxiliary Device . . . 165
Connecting the M320 Router to a Network for Out-of-Band Management . . . . 166
Connecting the M320 Router to an External Alarm-Reporting Device . . . . . . . . . 168
Connecting the M320 Router to an External Clocking Device . . . . . . . . . . . . . . . 168
Connecting Power to an AC-Powered M320 Router . . . . . . . . . . . . . . . . . . . . . . . 173
Connecting Power to a DC-Powered M320 Router . . . . . . . . . . . . . . . . . . . . . . . . 174
Installing and Replacing Components
Overview of Installing and Replacing Components . . . . . . . . . . . . . . . . . . . 185
Tools and Parts Required to Replace the M320 Hardware Components . . . . . . . 186
Copyright © 2015, Juniper Networks, Inc.
vii
M320 Multiservice Edge Router Hardware Guide
Replacing an M320 Management Ethernet Cable . . . . . . . . . . . . . . . . . . . . . . . . 192
Removing an M320 Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . . 194
Installing an M320 Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . . . 195
Replacing Cooling System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
Removing an M320 Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
Removing an M320 Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
Replacing Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Removing an M320 Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
Replacing a Solid-State Disk on an M320 RE-A-1800 Routing Engine . . . . . . . . 218
Removing an Solid-State Disk From an M320 RE-A-1800 Routing
Installing an Solid-State Disk on an M320 RE-A-1800 Routing Engine . . . . 219
Inserting or Removing a PC Card from an M320 Routing Engine . . . . . . . . . . . . . 219
Inserting a PC Card into an M320 Routing Engine . . . . . . . . . . . . . . . . . . . . . 220
Replacing a DIMM Module in an M320 Routing Engine . . . . . . . . . . . . . . . . . . . . . 221
Removing an M320 DIMM Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
Removing an M320 Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
viii Copyright © 2015, Juniper Networks, Inc.
Table of Contents
Part 5
Removing an M320 XENPAK Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
Installing an M320 XENPAK Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
Replacing Power System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
Removing an M320 AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
Installing an M320 AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
Removing an M320 DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
Installing an M320 DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
Replacing an M320 AC Power Supply Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
Replacing an M320 DC Power Supply Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
Replacing Switch Fabric Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
Maintaining the Chassis and Components
Routine Maintenance Procedures for the M320 Router . . . . . . . . . . . . . . . . . . . . 265
Maintaining Components and Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
Tools and Parts Required to Maintain the M320 Hardware Components . . . . . . 267
Copyright © 2015, Juniper Networks, Inc.
ix
M320 Multiservice Edge Router Hardware Guide
Part 6
Part 7
Part 8
Troubleshooting Hardware
M320 Troubleshooting Resources Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
M320 Chassis and Interface Alarm Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . 285
Contacting Customer Support and Returning the Chassis or
Components
Locating Component Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
Locating M320 Component Serial Numbers Using the CLI . . . . . . . . . . . . . . . . . 299
Locating the M320 Chassis Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . 300
Locating the M320 Craft Interface Serial Number Label . . . . . . . . . . . . . . . . . . . 301
Locating the M320 Routing Engine Serial Number Label . . . . . . . . . . . . . . . . . . . 301
Locating the M320 Power Supply Serial Number Labels . . . . . . . . . . . . . . . . . . . 304
Packing and Returning Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
Returning a Hardware Component to Juniper Networks, Inc. . . . . . . . . . . . . . . . . 307
Tools and Parts Required to Remove Components From an M320 Router . . . . 308
Packing M320 Router Components for Shipment . . . . . . . . . . . . . . . . . . . . . . . . 310
Safety and Compliance Information
General Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313
General Safety Guidelines for Juniper Networks Devices . . . . . . . . . . . . . . . . . . . 315
General Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . . . . . . . . . 316
Preventing Electrostatic Discharge Damage to an M320 Router . . . . . . . . . . . . . 318
x Copyright © 2015, Juniper Networks, Inc.
Table of Contents
Fire Safety Requirements for Juniper Networks Devices . . . . . . . . . . . . . . . . . . . . 321
Installation Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . 323
M320 General Installation Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . 323
Installation Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . . . . . . 324
Rack-Mounting Requirements and Warnings . . . . . . . . . . . . . . . . . . . . . . . . 325
Laser and LED Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . 331
Laser Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . . . . . . . . . . . 331
Radiation from Open Port Apertures Warning . . . . . . . . . . . . . . . . . . . . . . . . 333
Maintenance and Operational Safety Guidelines and Warnings . . . . . . . . 335
Maintenance and Operational Safety Warnings for Juniper Networks Devices . . 335
Electrical Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
General Electrical Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . 341
Grounding Requirements and Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
Midplane Energy Hazard Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
Multiple Power Supplies Disconnection Warning . . . . . . . . . . . . . . . . . . . . . 343
General Electrical Safety Guidelines and Electrical Codes for Juniper Networks
DC Power Electrical Safety Warnings for Juniper Networks Devices . . . . . . . . . . 347
DC Power Copper Conductors Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
DC Power Disconnection Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
DC Power Wiring Terminations Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
Copyright © 2015, Juniper Networks, Inc.
xi
M320 Multiservice Edge Router Hardware Guide
Part 9
Agency Approvals and Compliance Statements . . . . . . . . . . . . . . . . . . . . . . 351
Compliance Statements for EMC Requirements for Juniper Networks Devices
M320 Compliance Statements for EMC Requirements (European
Compliance Statements for EMC Requirements for Juniper Networks Devices
Compliance Statements for EMC Requirements for Juniper Networks Devices
Compliance Statements for EMC Requirements for Juniper Networks Devices
Compliance Statements for Environmental Requirements for Juniper Networks
M320 Compliance Statements for Acoustic Noise . . . . . . . . . . . . . . . . . . . . . . . 354
Index
xii Copyright © 2015, Juniper Networks, Inc.
List of Figures
Part 1
Part 2
Overview
Figure 1: Front View of a Fully Configured Router Chassis . . . . . . . . . . . . . . . . . . . . 8
Figure 2: Rear View of a Fully Configured AC-Powered Router Chassis . . . . . . . . . . 9
Figure 3: Rear View of a Fully Configured DC-Powered Router Chassis . . . . . . . . . 10
Cooling System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 21
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . 23
Figure 15: USB Memory Device in an Routing Engine . . . . . . . . . . . . . . . . . . . . . . . 30
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Figure 18: FPC1, FPC2, and FPC3 for the M320 Router . . . . . . . . . . . . . . . . . . . . . . 51
Figure 19: Enhanced II FPC1, FPC2, and FPC3 for the M320 Router . . . . . . . . . . . . 52
Figure 20: Enhanced III FPC1, FPC2, and FPC3 for the M320 Router . . . . . . . . . . . 52
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 73
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . 79
Site Planning, Preparation, and Specifications
Figure 26: Chassis Dimensions and Clearance Requirements . . . . . . . . . . . . . . . . 92
Copyright © 2015, Juniper Networks, Inc.
xiii
M320 Multiservice Edge Router Hardware Guide xiv
Part 3
Figure 28: DC Power and Grounding Cable Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Initial Installation and Configuration
Figure 33: Installing the Mounting Hardware for a Four-Post Rack or Cabinet . . 129
Figure 34: Center-Mounting Bracket Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Figure 35: Installing the Mounting Hardware for a Center-Mount Open-Frame
Installing the M320 With a Mechanical Lift . . . . . . . . . . . . . . . . . . . . . . . . . . 135
Figure 37: Removing an M320 Power Supply Before Installing the Installation
Installing the M320 Without a Mechanical Lift . . . . . . . . . . . . . . . . . . . . . . . 143
Figure 42: Removing a Power Supply Before Installing the Router . . . . . . . . . . . . 144
Connecting the M320 to External Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Figure 58: Routing Engine Management Ports and Alarm Relay Contacts . . . . . 164
Copyright © 2015, Juniper Networks, Inc.
List of Figures
Part 4
Figure 59: Console and Auxiliary Serial Port Connector . . . . . . . . . . . . . . . . . . . . 166
Figure 61: Routing Engine Ethernet Cable Connector . . . . . . . . . . . . . . . . . . . . . . 167
Figure 65: Connecting AC Power to the M320 Router . . . . . . . . . . . . . . . . . . . . . . 174
Figure 66: Connecting DC Power to the M320 Router . . . . . . . . . . . . . . . . . . . . . . 176
Installing and Replacing Components
Figure 70: Routing Engine Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . 195
Figure 71: Routing Engine Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . 196
Replacing Cooling System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
Replacing Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Figure 87: RE-A-1800 Routing Engine SSD Slots . . . . . . . . . . . . . . . . . . . . . . . . . 218
Figure 95: Connecting Fiber-Optic Cable to a PIC . . . . . . . . . . . . . . . . . . . . . . . . 233
Copyright © 2015, Juniper Networks, Inc.
xv
M320 Multiservice Edge Router Hardware Guide xvi
Part 5
Part 6
Part 7
Figure 98: Connecting Fiber-Optic Cable to a PIC . . . . . . . . . . . . . . . . . . . . . . . . 240
Figure 99: Small Form-Factor Pluggable (SFP) . . . . . . . . . . . . . . . . . . . . . . . . . . 241
Replacing Power System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
Figure 103: Rear of the Power Supply Showing Midplane Connector . . . . . . . . . 248
Figure 105: Disconnecting Power Cables from the DC Power Supply . . . . . . . . . . 251
Figure 108: Connecting Power Cables to the DC Power Supply . . . . . . . . . . . . . . 254
Figure 109: Disconnecting or Connecting a Power Cable from a DC Power
Replacing Switch Fabric Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
Maintaining the Chassis and Components
Maintaining Components and Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
Figure 113: Do Not Carry an FPC with Only One Hand . . . . . . . . . . . . . . . . . . . . . . 273
Troubleshooting Hardware
Contacting Customer Support and Returning the Chassis or
Components
Locating Component Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
Figure 120: M320 Chassis Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Figure 123: Routing Engine Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . 302
Figure 127: AC Power Supply Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . 305
Figure 128: DC Power Supply Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . 305
Copyright © 2015, Juniper Networks, Inc.
List of Figures
Part 8
Safety and Compliance Information
General Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313
Figure 130: Placing a Component into an Electrostatic Bag . . . . . . . . . . . . . . . . . 319
Copyright © 2015, Juniper Networks, Inc.
xvii
M320 Multiservice Edge Router Hardware Guide xviii Copyright © 2015, Juniper Networks, Inc.
List of Tables
Part 1
Overview
Table 3: Alarm LEDs and Alarm Cutoff/Lamp Test Button . . . . . . . . . . . . . . . . . . . 16
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . 23
Table 10: End-of-Life Routing Engine Specifications . . . . . . . . . . . . . . . . . . . . . . . 33
Table 30: Routing Engines on TX Matrix Plus with 3D SIBs . . . . . . . . . . . . . . . . . . 45
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Table 32: FPCs Supported by the M320 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Copyright © 2015, Juniper Networks, Inc.
xix
M320 Multiservice Edge Router Hardware Guide
Part 2
Table 33: ATM IQ PICs Supported by the M320 Router . . . . . . . . . . . . . . . . . . . . . 55
Table 34: ATM2 IQ PICs Supported by the M320 Router . . . . . . . . . . . . . . . . . . . . 56
Table 35: Channelized PICs Supported by the M320 Router . . . . . . . . . . . . . . . . . 56
Table 36: Channelized IQ PICs Supported by the M320 Router . . . . . . . . . . . . . . . 57
Table 37: Channelized IQE PICs Supported by the M320 Router . . . . . . . . . . . . . . 57
Table 38: Circuit Emulation PICs Supported by the M320 Router . . . . . . . . . . . . . 58
Table 39: DS3, E1, E3, and T1 PICs Supported by the M320 Router . . . . . . . . . . . . 58
Table 40: EIA-530 PIC Supported by the M320 Router . . . . . . . . . . . . . . . . . . . . . 59
Table 41: Fast Ethernet PICs Supported by the M320 Router . . . . . . . . . . . . . . . . 59
Table 42: Gigabit Ethernet PICs Supported by the M320 Router . . . . . . . . . . . . . . 60
Table 43: 10-Gigabit Ethernet PICs Supported by the M320 Router . . . . . . . . . . . 62
Table 44: Service PICs Supported by the M320 Router . . . . . . . . . . . . . . . . . . . . . 62
Table 45: SONET/SDH PICs Supported by the M320 Router . . . . . . . . . . . . . . . . . 63
Table 46: End-of-Life PICs Supported in the M320 Router . . . . . . . . . . . . . . . . . . 64
Table 48: M320 PIC/FPC Compatibility Type 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 73
Table 50: Components Powered by Each DC Power Supply Slot . . . . . . . . . . . . . 75
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . 79
Table 52: Performance per SIB/FPC Configuration . . . . . . . . . . . . . . . . . . . . . . . . 80
Site Planning, Preparation, and Specifications
Table 58: Component Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Table 63: DC Power System Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . 105
Table 64: Nonisolated DC Power Supply Electrical Specifications . . . . . . . . . . . 106
Table 65: Isolated DC Power Supply Electrical Specifications . . . . . . . . . . . . . . . 106
Network Cable and Transceiver Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Table 67: Estimated Values for Factors Causing Link Loss . . . . . . . . . . . . . . . . . . . 113
Management Cable and Transceiver Specifications and Pinouts . . . . . . . . 115
xx Copyright © 2015, Juniper Networks, Inc.
List of Tables
Part 3
Part 4
Part 6
Table 68: Cable and Wire Specifications for Routing Engine Management and
Initial Installation and Configuration
Table 71: M320 Router Parts List for a Fully Configured Router . . . . . . . . . . . . . . . 125
Table 73: Four-Post or Cabinet Rack Mounting Hole Locations . . . . . . . . . . . . . . 127
Table 74: Open-Frame Rack Mounting Hole Locations . . . . . . . . . . . . . . . . . . . . . 131
Installing and Replacing Components
Overview of Installing and Replacing Components . . . . . . . . . . . . . . . . . . . 185
Replacing Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Table 77: Effect of Taking the Host Subsystem Offline . . . . . . . . . . . . . . . . . . . . . 213
Troubleshooting Hardware
Table 79: SONET/SDH Interface Alarm Messages . . . . . . . . . . . . . . . . . . . . . . . . 286
Copyright © 2015, Juniper Networks, Inc.
xxi
M320 Multiservice Edge Router Hardware Guide xxii Copyright © 2015, Juniper Networks, Inc.
About the Documentation
•
Documentation and Release Notes on page xxiii
•
Supported Platforms on page xxiii
•
Documentation Conventions on page xxiii
•
Documentation Feedback on page xxv
•
Requesting Technical Support on page xxvi
Documentation and Release Notes
To obtain the most current version of all Juniper Networks
® technical documentation, see the product documentation page on the Juniper Networks website at http://www.juniper.net/techpubs/ .
If the information in the latest release notes differs from the information in the documentation, follow the product Release Notes.
Juniper Networks Books publishes books by Juniper Networks engineers and subject matter experts. These books go beyond the technical documentation to explore the nuances of network architecture, deployment, and administration. The current list can be viewed at http://www.juniper.net/books .
Supported Platforms
For the features described in this document, the following platforms are supported:
•
M320
Documentation Conventions
defines notice icons used in this guide.
Copyright © 2015, Juniper Networks, Inc.
xxiii
M320 Multiservice Edge Router Hardware Guide
Table 1: Notice Icons
Icon Meaning
Informational note
Caution
Warning
Laser warning
Tip
Best practice
Description
Indicates important features or instructions.
Indicates a situation that might result in loss of data or hardware damage.
Alerts you to the risk of personal injury or death.
Alerts you to the risk of personal injury from a laser.
Indicates helpful information.
Alerts you to a recommended use or implementation.
defines the text and syntax conventions used in this guide.
Table 2: Text and Syntax Conventions
Convention Description Examples
Bold text like this
Fixed-width text like this
Italic text like this
Italic text like this
Represents text that you type.
To enter configuration mode, type the configure command: user@host> configure
Represents output that appears on the terminal screen.
user@host> show chassis alarms
No alarms currently active
• Introduces or emphasizes important new terms.
•
•
Identifies guide names.
Identifies RFC and Internet draft titles.
•
•
•
A policy term is a named structure that defines match conditions and actions.
Junos OS CLI User Guide
RFC 1997, BGP Communities Attribute
Represents variables (options for which you substitute a value) in commands or configuration statements.
Configure the machine’s domain name:
[edit] root@# set system domain-name
domain-name
xxiv Copyright © 2015, Juniper Networks, Inc.
About the Documentation
Table 2: Text and Syntax Conventions (continued)
Convention Description
Text like this
< > (angle brackets)
| (pipe symbol)
Examples
Represents names of configuration statements, commands, files, and directories; configuration hierarchy levels; or labels on routing platform components.
•
•
To configure a stub area, include the stub statement at the [edit protocols ospf area area-id] hierarchy level.
The console port is labeled CONSOLE .
Encloses optional keywords or variables.
stub <default-metric metric>;
Indicates a choice between the mutually exclusive keywords or variables on either side of the symbol. The set of choices is often enclosed in parentheses for clarity.
broadcast | multicast
(string1 | string2 | string3)
# (pound sign)
[ ] (square brackets)
Indention and braces ( { } )
; (semicolon)
Indicates a comment specified on the same line as the configuration statement to which it applies.
rsvp { # Required for dynamic MPLS only
Encloses a variable for which you can substitute one or more values.
Identifies a level in the configuration hierarchy.
Identifies a leaf statement at a configuration hierarchy level.
community name members [
community-ids ]
[edit] routing-options { static { route default { nexthop address; retain;
}
}
}
GUI Conventions
Bold text like this
> (bold right angle bracket)
Represents graphical user interface (GUI) items you click or select.
•
•
In the Logical Interfaces box, select
All Interfaces .
To cancel the configuration, click
Cancel
.
Separates levels in a hierarchy of menu selections.
In the configuration editor hierarchy, select Protocols>Ospf.
Documentation Feedback
We encourage you to provide feedback, comments, and suggestions so that we can improve the documentation. You can provide feedback by using either of the following methods:
• Online feedback rating system—On any page at the Juniper Networks Technical
Documentation site at http://www.juniper.net/techpubs/index.html
, simply click the stars to rate the content, and use the pop-up form to provide us with information about your experience. Alternately, you can use the online feedback form at https://www.juniper.net/cgi-bin/docbugreport/ .
Copyright © 2015, Juniper Networks, Inc.
xxv
M320 Multiservice Edge Router Hardware Guide
•
E-mail—Send your comments to [email protected]. Include the document or topic name, URL or page number, and software version (if applicable).
Requesting Technical Support
Technical product support is available through the Juniper Networks Technical Assistance
Center (JTAC). If you are a customer with an active J-Care or JNASC support contract, or are covered under warranty, and need post-sales technical support, you can access our tools and resources online or open a case with JTAC.
• JTAC policies—For a complete understanding of our JTAC procedures and policies, review the JTAC User Guide located at http://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf
.
•
Product warranties—For product warranty information, visit http://www.juniper.net/support/warranty/ .
• JTAC hours of operation—The JTAC centers have resources available 24 hours a day,
7 days a week, 365 days a year.
Self-Help Online Tools and Resources
For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features:
•
Find CSC offerings: http://www.juniper.net/customers/support/
• Search for known bugs: http://www2.juniper.net/kb/
• Find product documentation: http://www.juniper.net/techpubs/
• Find solutions and answer questions using our Knowledge Base: http://kb.juniper.net/
• Download the latest versions of software and review release notes: http://www.juniper.net/customers/csc/software/
• Search technical bulletins for relevant hardware and software notifications: http://kb.juniper.net/InfoCenter/
•
Join and participate in the Juniper Networks Community Forum: http://www.juniper.net/company/communities/
•
Open a case online in the CSC Case Management tool: http://www.juniper.net/cm/
To verify service entitlement by product serial number, use our Serial Number Entitlement
(SNE) Tool: https://tools.juniper.net/SerialNumberEntitlementSearch/
Opening a Case with JTAC
You can open a case with JTAC on the Web or by telephone.
•
Use the Case Management tool in the CSC at http://www.juniper.net/cm/
.
•
Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).
xxvi Copyright © 2015, Juniper Networks, Inc.
About the Documentation
For international or direct-dial options in countries without toll-free numbers, see http://www.juniper.net/support/requesting-support.html
.
Copyright © 2015, Juniper Networks, Inc.
xxvii
M320 Multiservice Edge Router Hardware Guide xxviii Copyright © 2015, Juniper Networks, Inc.
PART 1
Overview
•
•
M320 Router Release Notes on page 5
•
Chassis Components and Descriptions on page 7
•
Cooling System Components and Descriptions on page 21
•
Host Subsystem Components and Descriptions on page 23
•
Line Card Components and Descriptions on page 49
•
Power System Components and Descriptions on page 73
•
Switch Fabric Components and Descriptions on page 79
Copyright © 2015, Juniper Networks, Inc.
1
M320 Multiservice Edge Router Hardware Guide
2 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 1
System Overview
•
M320 Router Description on page 3
•
M320 Component Redundancy on page 4
M320 Router Description
The M320 Multiservice Edge Router is a high-density edge aggregation, routing, and service creation platform that builds on Juniper Networks service-built edge design.
Constructed with separations between the control plane, forwarding plane, and services plane, the router supports multiple services on a single platform. The Junos OS runs on a control subsystem with dedicated hardware, ensuring that control functions are performed without affecting the forwarding subsystem. Forwarding and packet processing operations in the router are performed by dedicated programmable ASICs that enable the router to achieve data forwarding rates that match current fiber-optic capacity. This design eliminates processing and traffic bottlenecks, permitting the router to achieve high performance.
The router can be deployed in core, peering, and data center applications, but is optimized for dense edge aggregation and service creation. The M320 router can provide a single point of edge aggregation for thousands of customers over any access type, including
ATM, Frame Relay, Ethernet, and TDM, at any speed from DS0 up to OC192/STM64 and
10-Gigabit Ethernet.
The router is a half-rack chassis that supports up to eight Flexible PIC Concentrators
(FPCs) providing up to 64 SONET/SDH OC48/STM16, 16 SONET/SDH OC192/STM64, or 160 Gigabit Ethernet ports for the router. In a standalone configuration, the router's maximum aggregate throughput is 320 gigabits per second (Gbps), half duplex. The router supports up to eight of these FPCs:
•
Type 1 FPCs—Rated at 4 Gbps full duplex, supports up to four PICs.
• Type 2 FPCs—Rated at 16 Gbps full duplex, supports up to four PICs.
• Type 3 FPCs—Rated at 20 Gbps full duplex, supports up to two PICs, including higher-speed PICs.
The router can operate with any FPC type in any slot. Type 1 FPCs and Type 2 FPCs each support four PICs, and Type 3 FPCs supports two PICs.
Copyright © 2015, Juniper Networks, Inc.
3
M320 Multiservice Edge Router Hardware Guide
Related
Documentation
•
M320 Chassis Description on page 7
•
M320 Router Physical Specifications on page 86
•
M320 Environmental Specifications on page 93
•
M320 Power Requirements on page 96
M320 Component Redundancy
A fully configured router is designed so that no single point of failure can cause the entire system to fail. Only a fully configured router provides complete redundancy. All other configurations provide partial redundancy. The following major hardware components are redundant:
• Switch Interface Boards (SIBs)—A fully configured router has four SIBs. Each FPC has a dedicated ASIC with four high-speed links that connect to the SIBs (one link per SIB).
In the event of a complete SIB failure, the traffic is forwarded across the remaining three planes with a slight degradation in performance. When the failed SIB is replaced, the router regains full forwarding capacity.
• Host subsystem—The host subsystem consists of a Routing Engine functioning together with a CB. To operate, each host subsystem requires a Routing Engine installed in an adjacent slot to the CB. The router can have one or two host subsystems. If two host subsystems are installed, one functions as the master and the other functions as the backup. If the master host subsystem (or either of its components) fails or is taken offline, the backup can take over as the master.
For information about the effect of taking the host subsystem offline, see
M320 Host Subsystem Offline” on page 213 . For more information about high availability
features, see the Junos OS High Availability Library for Routing Devices.
•
Power supplies—A router with a minimum of three AC power supplies or four DC power supplies is fully power redundant. In the AC configuration, all power supplies share the load evenly. In the DC configuration, two power supplies share the load to some of the components, and two other power supplies share the load to the remaining components. In both configurations, if one power supply fails, the remaining power supplies can provide full power to the router.
• Cooling system—The cooling system has redundant components, which are controlled by the host subsystem. If one of the fans fails, the host subsystem increases the speed of the remaining fans to provide sufficient cooling for the router indefinitely.
Related
Documentation
•
M320 SIB Description on page 79
•
M320 Host Subsystem Description on page 23
•
M320 Cooling System Description on page 21
•
M320 Power System Description on page 73
4 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 2
M320 Router Release Notes
•
Outstanding Issues with the M320 Router on page 5
•
Errata with the M320 Router Documentation on page 5
Outstanding Issues with the M320 Router
This section lists outstanding hardware issues with the M320 Multiservice Edge Router.
For information about software issues, see the Junos OS Release Notes.
• There are currently no outstanding issues for the M320 router.
Related
Documentation
•
Errata with the M320 Router Documentation on page 5
Errata with the M320 Router Documentation
There are currently no outstanding documentation issues for the M320 router.
Related
Documentation
•
Outstanding Issues with the M320 Router on page 5
Copyright © 2015, Juniper Networks, Inc.
5
M320 Multiservice Edge Router Hardware Guide
6 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 3
Chassis Components and Descriptions
•
M320 Chassis Description on page 7
•
M320 Midplane Description on page 10
•
•
M320 Cable Management System Description on page 12
•
M320 Connector Interface Panel (CIP) Description on page 13
•
M320 Craft Interface Description on page 15
•
M320 Craft Interface Alarm LEDs and ACO/LT Button on page 16
•
M320 Craft Interface LED Display and Navigation Buttons on page 16
•
M320 Craft Interface Host Subsystem LEDs on page 18
•
M320 Craft Interface FPC LEDs and Online/Offline Buttons on page 18
•
M320 Craft Interface Power Supply LEDs on page 19
•
M320 Craft Interface SIB LEDs on page 19
M320 Chassis Description
The router chassis is a rigid sheet metal structure that houses all the other router components (see
). The chassis measures 34.80 in. (88.4 cm) high,
17.43 in. (44.3 cm) wide, and 25.64 in. (65.1 cm) deep (from the front-mounting flanges to the rear of the chassis). The chassis can be installed in many types of racks or cabinets.
For more information, see
“M320 Cabinet Size and Clearance Requirements” on page 88 ,
and
“Rack Requirements for the M320 Router” on page 87
.
The chassis includes the following features (see
,
, and
•
One pair of metal adjustable center-mounting brackets that can be attached to one of 11 positions on the side of the chassis. You can use the brackets for mounting the chassis in the rack or cabinet.
•
Two installation handles on the top to facilitate positioning the router in the rack. Do not use the handles to lift the router.
• Two electrostatic discharge points (banana plug receptacles): one front and one rear.
Copyright © 2015, Juniper Networks, Inc.
7
M320 Multiservice Edge Router Hardware Guide
CAUTION: Before removing or installing components of a router, attach an ESD strap to an ESD point and place the other end of the strap around your bare wrist. Failure to use an ESD strap could result in damage to the router.
Figure 1: Front View of a Fully Configured Router Chassis
8 Copyright © 2015, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
Figure 2: Rear View of a Fully Configured AC-Powered Router Chassis
Copyright © 2015, Juniper Networks, Inc.
9
M320 Multiservice Edge Router Hardware Guide
Figure 3: Rear View of a Fully Configured DC-Powered Router Chassis
For chassis serial number information , see
“Locating M320 Component Serial Numbers
.
Related
Documentation
•
M320 Router Description on page 3
•
Installing the M320 Chassis Using a Mechanical Lift on page 136
•
Installing the M320 Chassis in the Rack Manually on page 151
•
M320 Installation Safety Guidelines on page 323
•
M320 Router Physical Specifications on page 86
M320 Midplane Description
The midplane is located in the center of the chassis and forms the rear of the FPC card cage (see
). The FPCs install into the midplane from the front of the
10 Copyright © 2015, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions chassis, and the SIBs, Routing Engines, and CBs install into the midplane from the rear of the chassis. The power supplies and cooling system components also connect to the midplane.
The midplane performs the following major functions:
•
Data path—Data packets are transferred across the midplane from the Packet
Forwarding Engine on the originating FPC to the SIBs, and from the SIBs across the midplane to the Packet Forwarding Engine on the destination FPC.
•
Power distribution—The router power supplies are connected to the midplane, which distributes power to all the router components.
• Signal path—The midplane provides the signal path to the FPCs, SIBs, Routing Engines,
CB, and other system components for monitoring and control of the system.
Figure 4: Midplane
For chassis serial number information , see
“Locating M320 Component Serial Numbers
.
Copyright © 2015, Juniper Networks, Inc.
11
M320 Multiservice Edge Router Hardware Guide
Related
Documentation
•
M320 Router Description on page 3
•
M320 Host Subsystem Description on page 23
•
M320 Cabinet Size and Clearance Requirements on page 88
M320 Fuses
The router uses fuses from the Cooper Bussman brand GMT series for the CB, SIBs, and
FPCs. The fuses are located in the rear of the midplane behind the power supply in slot
PEM0
. When the fuse for a component blows, the component stops functioning even though it is installed correctly and the power supplies are providing power to the router.
For more information, see
“Troubleshooting the M320 Fuses” on page 290 . For fuse
replacement instructions, see
“Replacing an M320 Fuse” on page 199 .
Related
Documentation
•
M320 Fuse Specifications on page 99
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
M320 Cable Management System Description
The cable management system (see
) consists of a row of nine semicircular plastic bobbins mounted on the front of the router below the FPC card cage.
The PIC cables pass between the bobbins and into the tray, keeping the cables organized and securely in place. The curvature of the bobbins also helps maintain the proper bend radius for optical PIC cables.
You can pull the cable management system up and outward to lock it into the maintenance position. This allows you to access the lower fan tray and the front air filter.
Figure 5: Cable Management System
12
The router; ships with an accessory box that contains four cable guards—two upper and two lower—that you can install on the front-mounting flanges of the chassis after you have mounted the chassis in a rack or cabinet. The cable guards protect the PIC and CIP cables from rubbing against the front edges of the chassis.
Included with your router shipment is a clear plastic cable cover that you can attach to slots in the cable guards without using tools. The cable cover prevents the PIC and CIP cables from being disturbed or snagged.
Copyright © 2015, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
Related
Documentation
•
M320 Chassis Description on page 7
M320 Connector Interface Panel (CIP) Description
The CIP is located at the left side of the FPC card cage. The front electrostatic discharge point is located near the bottom of the CIP.
•
•
Routing Engine Ports on page 14
•
Alarm Relay Contacts on page 15
CIP Components
The Connector Interface Panel (CIP) consists of Ethernet, console, and auxiliary connectors for the Routing Engines and alarm relay contacts (see
).
Copyright © 2015, Juniper Networks, Inc.
13
M320 Multiservice Edge Router Hardware Guide
Figure 6: CIP
Routing Engine Ports
The CIP has two sets of ports that you use to connect the Routing Engines to external management devices. From these management devices, you can use the CLI to configure the router.
The upper set of ports, labeled HOST 0, connects to the Routing Engine in slot RE0; and the lower set, labeled HOST 1, connects to the Routing Engine in slot RE1. Each set includes the following ports:
•
ETHERNET
—Connects the Routing Engine through an Ethernet connection to a management LAN (or any other device that plugs into an Ethernet connection) for
14 Copyright © 2015, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions out-of-band management. The port uses an autosensing RJ-45 connector to support both 10- and 100-Mbps connections. Two small LEDs on the right edge of the port indicate the connection in use: the LED labeled ETHERNET lights yellow or green for a
10-Mbps or 100-Mbps connection, and the LED labeled ACT lights green when traffic is passing through the port.
• CONSOLE
—Connects the Routing Engine to a system console through an RS-232
(EIA-232) serial cable.
• AUX
— Connects the Routing Engine to a laptop, modem, or other auxiliary device through an RS-232 (EIA-232) serial cable.
Alarm Relay Contacts
The CIP has two alarm relay contacts for connecting the router to external alarm devices.
Whenever a system condition triggers either the red or yellow alarm on the craft interface, the alarm relay contacts are also activated. The alarm relay contacts are located below the Routing Engine ports. The terminal blocks that plug into the alarm relay contacts are supplied with the router. They accept wire of any gauge between 28-AWG and 14-AWG
(0.08 and 2.08 mm
2
), which is not provided. Use the gauge of wire appropriate for the external device you are connecting.
Related
Documentation
•
M320 Craft Interface Description on page 15
•
Replacing the M320 CIP on page 189
M320 Craft Interface Description
The craft interface allows you to view status and troubleshooting information at a glance and to perform many system control functions. It is hot-insertable and hot-removable.
The craft interface is located on the front of the router above the FPCs.
shows the front panel of the M320 craft interface.
Figure 7: Front Panel of the Craft Interface
Related
Documentation
•
M320 Craft Interface Alarm LEDs and ACO/LT Button on page 16
•
M320 Craft Interface Host Subsystem LEDs on page 18
•
Replacing an M320 Craft Interface on page 197
Copyright © 2015, Juniper Networks, Inc.
15
M320 Multiservice Edge Router Hardware Guide
M320 Craft Interface Alarm LEDs and ACO/LT Button
Two large alarm LEDs are located at the upper left of the craft interface . The circular red LED lights to indicate a critical condition that can result in a system shutdown. The triangular yellow LED lights to indicate a less severe condition that requires monitoring or maintenance. Both LEDs can be lit simultaneously.
A condition that causes an LED to light also activates the corresponding alarm relay contact on the connector interface panel (CIP). The LCD on the craft interface reports the cause of the alarm.
To deactivate red and yellow alarms, press the button labeled ACO/LT (for “alarm cutoff/lamp test”), which is located to the right of the alarm LEDs. Deactivating an alarm turns off both LEDs and deactivates the device attached to the corresponding alarm relay contact on the CIP. However, the LCD continues to report the alarm message until you clear the condition that caused the alarm.
describes the alarm LEDs and alarm cutoff button in more detail.
Table 3: Alarm LEDs and Alarm Cutoff/Lamp Test Button
Shape Color State Description
Red
Yellow
—
On steadily Critical alarm LED—Indicates a critical condition that can cause the router to stop functioning. Possible causes include component removal, failure, or overheating.
On steadily Warning alarm LED—Indicates a serious but nonfatal error condition, such as a maintenance alert or a significant increase in component temperature.
— Alarm cutoff/lamp test button—Deactivates red and yellow alarms. Causes all LEDs on the craft interface to light (for testing purposes), when pressed and held.
Related
Documentation
•
M320 Craft Interface Description on page 15
•
M320 Connector Interface Panel (CIP) Description on page 13
•
M320 Craft Interface LED Display and Navigation Buttons on page 16
M320 Craft Interface LED Display and Navigation Buttons
A four-line LED display is located in the craft interface, along with six navigation buttons.
The LED display operates in two modes:
• LED display idle mode
•
LED display alarm mode
16 Copyright © 2015, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
During normal operation, the LED display operates in idle mode and reports current status information, as shown in
.
Figure 8: LED Display in Idle Mode
The lines in the display report the following information:
• First line—Router name.
•
Second line—Length of time the router has been running, reported in the following form:
Up days + hours:minutes
•
Third and fourth lines—Status messages, which rotate at 2-second intervals. Some conditions, such as removal or insertion of a system component, can interrupt the messages.
To add a message that alternates every 2 seconds with the default status messages, use the set chassis display message command. For more information, see the
CLI Explorer
.
When a red or yellow alarm occurs, the LED display switches to alarm mode and reports about the alarm condition, as shown in
.
Figure 9: LED Display in Alarm Mode
The lines in the display report the following information:
•
First line—Router name.
• Second line—Number of active alarms.
• Third and fourth lines—Individual alarm messages, with the most severe condition shown first. The prefix on each line indicates whether the alarm is a red (R) or yellow (Y) alarm.
For a list of alarm messages that can appear on the LED display, see
Interface Alarm Messages” on page 285
.
Copyright © 2015, Juniper Networks, Inc.
17
M320 Multiservice Edge Router Hardware Guide
Related
Documentation
•
M320 Craft Interface Description on page 15
•
M320 Craft Interface Alarm LEDs and ACO/LT Button on page 16
M320 Craft Interface Host Subsystem LEDs
Each host subsystem has three LEDs, located in the middle of the craft interface, that indicate its status. The LEDs labeled RE0 show the status of the Routing Engine in slot
RE0 and the CB in slot CB0. The LEDs labeled RE1 show the status of the Routing Engine in slot RE1 and the CB in slot CB1.
describes the functions of the host subsystem LEDs.
Table 4: M320 Host Subsystem LEDs
Label Color State Description
Red On steadily Host is offline.
FAIL
OK
MASTER
Green
Green
On steadily Host is online and is functioning normally.
On steadily Host is functioning as the master.
Related
Documentation
•
M320 Host Subsystem Description on page 23
•
M320 Craft Interface Description on page 15
•
M320 Craft Interface Alarm LEDs and ACO/LT Button on page 16
M320 Craft Interface FPC LEDs and Online/Offline Buttons
Each FPC slot has two LEDs that indicate its status. The FPC LEDs, labeled FPC0 through
FPC7 , are located along the bottom of the craft interface.
describes the functions of the FPC LEDs.
Table 5: FPC LEDs
Label Color State Description
FAIL
OK
Red
Green
On steadily FPC has failed.
On steadily FPC is functioning normally.
Blinking FPC is starting up.
Related
Documentation
•
M320 Flexible PIC Concentrator (FPC) Description on page 49
•
M320 Craft Interface Description on page 15
•
M320 Connector Interface Panel (CIP) Description on page 13
•
Troubleshooting the M320 FPCs on page 289
18 Copyright © 2015, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
M320 Craft Interface Power Supply LEDs
Each power supply has two LEDs on the craft interface that indicate its status. The LEDs, labeled 0 through 3, are located in the middle of the craft interface under the POWER label.
describes the functions of the power supply LEDs.
Table 6: Power Supply LEDs on the Craft Interface
Label Color State Description
FAIL
OK
Red
Green
On steadily Power supply has failed.
On steadily Power supply is functioning normally.
Related
Documentation
•
M320 Craft Interface Description on page 15
•
M320 AC Power Supplies Description on page 73
•
M320 DC Power Supplies Description on page 74
M320 Craft Interface SIB LEDs
Each SIB has two LEDs on the craft interface that indicate its status. The SIB LEDs, labeled
SIB0 through SIB2, are located on the upper right of the craft interface. The ACTIVE LED on the SIB faceplate is not replicated on the craft interface.
describes the functions of the SIB LEDs.
Table 7: SIB LEDs on the Craft Interface
Label Color State Description
Red On steadily SIB has failed.
FAIL
OK Green On steadily SIB is functioning normally.
Related
Documentation
•
M320 SIB Description on page 79
•
•
M320 Craft Interface Description on page 15
•
Maintaining the M320 SIBs on page 279
Copyright © 2015, Juniper Networks, Inc.
19
M320 Multiservice Edge Router Hardware Guide
20 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 4
Cooling System Components and
Descriptions
•
M320 Cooling System Description on page 21
M320 Cooling System Description
The cooling system consists of the following components:
•
Two front fan trays
• Front air filter
• Rear fan tray
•
Rear air filter
The cooling system components work together to keep all router components within the acceptable temperature range (see
). All fan trays and filters are hot-insertable and hot-removable. The two front fan trays are interchangeable. The front and rear fan trays are not interchangeable.
Figure 10: Airflow Through the Chassis
Copyright © 2015, Juniper Networks, Inc.
21
M320 Multiservice Edge Router Hardware Guide
The host subsystem monitors the temperature of the router components. When the router is operating normally, the fans function at lower than full speed. If a fan fails or the ambient temperature rises above a threshold, the speed of the remaining fans is automatically adjusted to keep the temperature within the acceptable range. If the ambient maximum temperature specification is exceeded and the system cannot be adequately cooled, the Routing Engine shuts down some or all of the hardware components.
Related
Documentation
•
M320 Cabinet Airflow Requirements on page 90
•
Maintaining the M320 Fan Trays on page 268
•
Troubleshooting the M320 Cooling System on page 287
22 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 5
Host Subsystem Components and
Descriptions
•
M320 Host Subsystem Description on page 23
•
M320 Routing Engine Description on page 24
•
M320 Routing Engine 600 Description on page 25
•
M320 Routing Engine 1600 Description on page 26
•
M320 Routing Engine 2000 Description on page 27
•
M320 RE-A-1800 Routing Engine Description on page 28
•
RE-A-1800 Routing Engine LEDs on page 31
•
Routing Engine Specifications on page 31
•
Supported Routing Engines by Router on page 34
•
M320 Control Board (CB) Description on page 45
•
M320 Control Board (CB) LEDs on page 46
M320 Host Subsystem Description
The host subsystem provides the routing and system management functions of the router. You can install one or two host subsystems on the router. To operate, each host subsystem functions as a unit; the Routing Engine requires the corresponding Control
Board (CB) and vice versa.
NOTE: We recommend that you install two host subsystems for redundant protection. If you install only one host subsystem, we recommend that you install it in slot RE0.
NOTE: Each host subsystem has three LEDs that display its status. The LEDs that report host module status (including Routing Engine status) are located in the middle of the craft interface rather than the Routing Engine faceplate.
For more information about the host subsystem LEDs, see
Interface Host Subsystem LEDs” on page 18 .
Copyright © 2015, Juniper Networks, Inc.
23
M320 Multiservice Edge Router Hardware Guide
NOTE: For specific information about Routing Engine components (for example, the amount of DRAM), issue the show chassis routing-engine command.
NOTE: If two Routing Engines are installed, they must both be the same hardware model.
Related
Documentation
•
Maintaining the M320 Host Subsystem on page 269
•
Taking the M320 Host Subsystem Offline on page 213
M320 Routing Engine Description
The Routing Engine runs the Junos operating system (OS). The software processes that run on the Routing Engine maintain the routing tables, manage the routing protocols used on the router, control the router interfaces, control some chassis components, and provide the interface for system management and user access to the router.
You can install one or two Routing Engines in the router. The Routing Engines install into the upper rear of the chassis in the slots labeled RE0 and RE1. Each Routing Engine requires a CB to be installed in the adjacent slot. RE0 installs below CB0, and RE1 installs above
CB1 . A Routing Engine does not power up if a CB is not present in the adjacent slot.
If two Routing Engines are installed, one functions as the master, and the other acts as the backup. If the master Routing Engine fails or is removed, and the backup is configured appropriately, the backup can take over as the master. If the Routing Engines are configured for nonstop active routing, the backup Routing Engine automatically synchronizes its configuration and state with the master Routing Engine. Any update to the master Routing Engine state is replicated on the backup Routing Engine. If the backup
Routing Engine assumes mastership, packet forwarding continues through the router without interruption. For more information about nonstop active routing, see the Junos
OS High Availability Library for Routing Devices.
The master Routing Engine (if nonstop active routing is configured) and the backup
Routing Engine are hot-removable and hot-insertable. A nonredundant Routing Engine or master Routing Engine (if nonstop active routing is not configured) is hot-pluggable.
The M320 router supports the following Routing Engines:
•
RE-600-2048
• RE-1600-2048
• RE-A-2000-4096
•
RE-A-1800x2 for Junos OS Release 10.4.
24 Copyright © 2015, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Related
Documentation
•
M320 Connector Interface Panel (CIP) Description on page 13
•
Replacing an M320 Routing Engine on page 216
•
M320 Routing Engine 600 Description on page 25
•
M320 Routing Engine 1600 Description on page 26
•
M320 Routing Engine 2000 Description on page 27
•
M320 RE-A-1800 Routing Engine Description on page 28
M320 Routing Engine 600 Description
Each M320 Routing Engine 600 consists of the following components:
•
CPU—Runs Junos OS to maintain the router's routing tables and routing protocols. It has a Pentium-class processor.
• DRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
•
CompactFlash card—Provides primary storage for software images, configuration files, and microcode. The CompactFlash card is inaccessible from outside the router.
• Hard disk—Provides secondary storage for log files, memory dumps, and rebooting the system if the CompactFlash card fails.
•
One PC card slot—Accepts a removable PC card, which stores software images for system upgrades.
• LED—Indicates disk activity for the internal IDE interface. It does not necessarily indicate routing-related activity.
•
Interfaces for out-of-band management access—Provide information about
Routing Engine status to devices (console, laptop, or terminal server) that can be attached to access ports located on the Connector Interface Panel (CIP).
Each Routing Engine has one 10/100-Mbps Ethernet port for connecting to a management network, and two asynchronous serial ports—one for connecting to a console and one for connecting to a modem or other auxiliary device.
• EEPROM—Stores the serial number of the Routing Engine.
•
Reset button—Reboots the Routing Engine when pressed.
On the RE-600-2048 Routing Engine, the boot sequence for the storage media is as follows: the PC card (if present), then the CompactFlash card (if present), then the hard disk.
The device from which the router boots is called the primary boot device, and the other device is the alternate boot device.
NOTE: If the router boots from an alternate boot device, a yellow alarm lights the LED on the router’s craft interface.
Copyright © 2015, Juniper Networks, Inc.
25
M320 Multiservice Edge Router Hardware Guide
Related
Documentation
•
M320 Connector Interface Panel (CIP) Description on page 13
•
M320 Routing Engine Description on page 24
•
Replacing an M320 Routing Engine on page 216
M320 Routing Engine 1600 Description
Figure 11: Routing Engine 1600
26
Each Routing Engine (shown in
Figure 11 on page 26 ) consists of the following components:
• CPU—Runs Junos OS to maintain the router's routing tables and routing protocols. It has a Pentium-class processor.
•
DRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• CompactFlash card—Provides primary storage for software images, configuration files, and microcode. The CompactFlash card is inaccessible from outside the router.
•
Hard disk—Provides secondary storage for log files, memory dumps, and rebooting the system if the CompactFlash card fails.
• PC card slots—Accept removable PC cards, which store software images for system upgrades.
•
LED—Indicates disk activity for the internal IDE interface. It does not necessarily indicate routing-related activity.
• Interfaces for out-of-band management access—Provide information about
Routing Engine status to devices (console, laptop, or terminal server) that can be attached to access ports located on the Connector Interface Panel (CIP).
Each Routing Engine has one 10/100-Mbps Ethernet port for connecting to a management network, and two asynchronous serial ports—one for connecting to a console and one for connecting to a modem or other auxiliary device.
•
EEPROM—Stores the serial number of the Routing Engine.
•
Reset button—Reboots the Routing Engine when pressed.
Copyright © 2015, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
On the RE-1600-2048 Routing Engine, the boot sequence for the storage media is as follows: the PC card in SLOT 0 (if present), then the PC card in SLOT 1 (if present), then the CompactFlash card (if present), then the hard disk.
The device from which the router boots is called the primary boot device, and the other device is the alternate boot device.
NOTE: If the router boots from an alternate boot device, a yellow alarm lights the LED on the router’s craft interface.
Related
Documentation
•
M320 Connector Interface Panel (CIP) Description on page 13
•
M320 Routing Engine Description on page 24
•
Replacing an M320 Routing Engine on page 216
M320 Routing Engine 2000 Description
Each Routing Engine (shown in
) consists of the following components:
• CPU—Runs Junos OS to maintain the router's routing tables and routing protocols. It has a Pentium-class processor.
•
DRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• CompactFlash card—Provides primary storage for software images, configuration files, and microcode. The CompactFlash card is inaccessible from outside the router.
•
Hard disk—Provides secondary storage for log files, memory dumps, and rebooting the system if the CompactFlash card fails.
• USB port—Provides a removable media interface through which you can install the
Junos OS manually. The Junos OS supports USB version 1.0.
•
LED—Indicates disk activity for the internal IDE interface. It does not necessarily indicate routing-related activity.
• Interfaces for out-of-band management access—Provide information about
Routing Engine status to devices (console, laptop, or terminal server) that can be attached to access ports located on the Connector Interface Panel (CIP).
Each Routing Engine has one 10/100-Mbps Ethernet port for connecting to a management network, and two asynchronous serial ports—one for connecting to a console and one for connecting to a modem or other auxiliary device.
•
EEPROM—Stores the serial number of the Routing Engine.
•
Reset button—Reboots the Routing Engine when pressed.
Copyright © 2015, Juniper Networks, Inc.
27
M320 Multiservice Edge Router Hardware Guide
Figure 12: Routing Engine 2000
On the RE-A-2000-4096 Routing Engine, the boot sequence for the storage media is as follows: USB device (if present), then the CompactFlash card (if present), then the hard disk.
The device from which the router boots is called the primary boot device, and the other device is the alternate boot device.
NOTE: If the router boots from an alternate boot device, a yellow alarm lights the LED on the router’s craft interface.
Related
Documentation
•
M320 Connector Interface Panel (CIP) Description on page 13
•
M320 Routing Engine Description on page 24
•
Replacing an M320 Routing Engine on page 216
M320 RE-A-1800 Routing Engine Description
•
Routing Engine Components on page 28
•
Routing Engine Boot Sequence on page 30
Routing Engine Components
Each Routing Engine (shown in
and
Figure 14 on page 29 ) consists
of the following components:
•
CPU—Runs Junos OS to maintain the router's routing tables and routing protocols.
•
DRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• USB port—Provides a removable media interface through which you can install the
Junos OS manually. See
. Junos supports USB version 1.0.
•
CompactFlash card—Provides primary storage for software images, configuration files, and microcode. The disk is a fixed compact flash and is inaccessible from outside the router.
28 Copyright © 2015, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
•
SSD—Provides storage for log files, memory dumps, and rebooting the system if the
CompactFlash card fails.
• LED—Indicates disk activity. It does not necessarily indicate routing-related activity.
NOTE: The LEDs that report host module status (including Routing Engine status) are on the craft interface rather than the Routing Engine faceplate.
• Storage LED—Indicates disk activity for the solid state disk drive.
•
Interfaces for out-of-band management access—Provide information about
Routing Engine status to devices (console, laptop, or terminal server) that can be attached to access ports located on the craft interface.
Each Routing Engine has one 10/100-Mbps Ethernet port for connecting to a management network, and two asynchronous serial ports—one for connecting to a console and one for connecting to a modem or other auxiliary device.
• EEPROM—Stores the serial number of the Routing Engine.
• Reset button—Reboots the Routing Engine when pressed.
•
Offline button—Takes the Routing Engine offline when pressed.
•
Extractor clips—Control the locking system that secures the Routing Engine.
Figure 13: RE-A-1800 Routing Engine
Online/Offline button
SSD slot 1
SSD slot 2
Extractor clip
USB port
Reset button
Figure 14: RE-A-1800x2 Routing Engine
SSD slot 1
SSD slot 2
Online
LED
Storage
LED
Extractor clip
Extractor clip
USB port
Reset button
Online/Offline button Extractor clip
Copyright © 2015, Juniper Networks, Inc.
29
M320 Multiservice Edge Router Hardware Guide
NOTE: For specific information about Routing Engine components (for example, the amount of DRAM), issue the show chassis routing-engine command.
Figure 15: USB Memory Device in an Routing Engine
Routing Engine Boot Sequence
The Routing Engine boots from the storage media in this order: the USB device, then the
CompactFlash card (if present), then the two solid state drives (SSD) and then the LAN.
The device from which the router boots is called the primary boot device, and the other device is the alternate boot device.
NOTE: If the router boots from an alternate boot device, a yellow alarm lights the LED on the router’s craft interface.
Related
Documentation
•
M320 Routing Engine Description on page 24
•
M320 Host Subsystem Description on page 23
•
RE-A-1800 Routing Engine LEDs on page 31
•
Maintaining the M320 Host Subsystem on page 269
•
Taking the M320 Host Subsystem Offline on page 213
30 Copyright © 2015, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
RE-A-1800 Routing Engine LEDs
Each Routing Engine has four LEDs that indicate its status. The LEDs, labeled MASTER,
STORAGE
, ONLINE, and OK/FAIL, are located directly on the faceplate of the Routing
Engine.
describes the functions of the Routing Engine LEDs.
Table 8: Routing Engine LEDs
Label Color State Description
Blue On steadily Routing Engine is the Master.
MASTER
STORAGE
ONLINE
OK/FAIL
Green
Green
Red
Blinking
Blinking
Indicates activity on the SSD or Compact Flash.
Routing Engine is transitioning online.
On steadily Routing Engine is functioning normally.
On steadily Routing Engine has failed.
Related
Documentation
•
•
M320 RE-A-1800 Routing Engine Description on page 28
•
Maintaining the M320 Host Subsystem on page 269
Routing Engine Specifications
lists the current specifications for Routing Engines supported on M
Series, MX Series, and T Series routers.
lists the specifications for end-of-life Routing Engines.
NOTE: For information about PTX Series Routing Engine specifications, see
Routing Engines Supported on PTX Series Routers
Table 9: Routing Engine Specifications
Routing
Engine Processor Memory
Connection to PFEs
RE-400-768 400-MHz
Celeron
RE-A-1000-2048 1.0-GHz
Pentium
768 MB
2048 MB Gigabit
Ethernet
Disk
Fast Ethernet 40 GB Hard disk
40 GB Hard disk
Media
First Junos OS
Support
1 GB
CompactFlash card
9.0
1 GB
CompactFlash card
8.1
Copyright © 2015, Juniper Networks, Inc.
31
M320 Multiservice Edge Router Hardware Guide
Table 9: Routing Engine Specifications (continued)
Routing
Engine Processor Memory
Connection to PFEs
RE-A-2000-4096 2.0-GHz
Pentium
RE-S-1300-2048 1.3-GHz
Pentium
RE-S-2000-4096 2.0-GHz
Pentium
RE-C1800
RE-C2600
RE-A-1800x2 1800-MHz
RE-S-1800x2 1800-MHz
RE-S-1800x4 1800-MHz
RE-S-MX104
1.8-GHz
2.6-GHz
1.8-GHz
RE-B-1800x1-4G 1.73-GHz
RE-MX2000-1800x4 1800-GHz
RE-S-1800X4-32G-S 1800 Ghz
4096 MB
2048 MB
4096 MB
8 GB
16 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
8 GB or 16 GB Gigabit
Ethernet
8 GB or 16 GB Gigabit
Ethernet
8GB or 16 GB Gigabit
Ethernet
4 GB
4 GB
16 GB
32 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Disk
40 GB Hard disk
40 GB Hard disk
40 GB Hard disk
SSD
SSD
32 GB SSD
32 GB SSD
32 GB SSD
–
64 GB SSD
–
32 GB SSD
Media
First Junos OS
Support
1 GB
CompactFlash card
8.1
1 GB
CompactFlash card
8.2
1 GB
CompactFlash card
8.2
4 GB
CompactFlash card
T1600 router in a routing matrix: 9.6R2
Standalone T640 or
T1600 router:11.2
4 GB
CompactFlash card
TX Matrix Plus router: 9.6R2
4 GB
CompactFlash card
10.4
4 GB
CompactFlash card
10.4
4 GB
CompactFlash card
10.4
8 GB NAND
Flash
13.2
4 GB
CompactFlash card
12.1R2, 11.4R4, and
12.2R1
4 GB Fixed
Internal
CompactFlash card
12.3R2
4 GB Fixed
Internal
CompactFlash card
•
•
12.3R4
13.2R1
32 Copyright © 2015, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 9: Routing Engine Specifications (continued)
Routing
Engine Processor Memory
Connection to PFEs
REMX2K-1800-32G-S 1800 Ghz 32 GB Gigabit
Ethernet
Disk
–
Media
First Junos OS
Support
4 GB Fixed
Internal
CompactFlash card
•
•
12.3R4
13.2R1
Table 10: End-of-Life Routing Engine Specifications
Routing
Engine Processor Memory
RE-333-256 333-MHz
Pentium II
256 MB
RE-333-768 333-MHz
Pentium II
768 MB
RE-600-512 600-MHz
Pentium III
512 MB
Connection to PFEs Disk
Fast
Ethernet
Fast
Ethernet
Fast
Ethernet
Media
6.4 GB
Hard disk
6.4 GB
Hard disk
80 MB
CompactFlash card
3.4
80 MB
CompactFlash card
3.4
30 GB Hard disk
256 MB
CompactFlash card
5.4
First Junos OS
Support EOL Details
PSN-2003-01-063
PSN-2003-01-063
PSN-2004-07-019
RE-600-2048 600-MHz
Pentium III
2048 MB Fast
Ethernet
PSN-2008-02-018
RE-850-1536 850-MHz
Pentium III
1536 MB
RE-M40 200-MHz
Pentium
256 MB
RE-M40-333-768 333-MHz
Pentium II
768 MB
RE-M40-600-2048 600-MHz
Pentium III
2048 MB
RE-1600-2048 1.6-GHz
Pentium M
2048 MB
Fast
Ethernet
Fast
Ethernet
Fast
Ethernet
Fast
Ethernet
Gigabit
Ethernet
40 GB Hard disk
1 GB
CompactFlash card
5.3
40 GB Hard disk
1 GB
CompactFlash card
7.2
6.4 GB
Hard disk
80 MB
CompactFlash card
3.2
10 GB Hard disk
80 MB
CompactFlash card
4.2
30 GB Hard disk
128 MB
CompactFlash card
5.4
40 GB Hard disk
1 GB
CompactFlash card
6.2
PSN-2011-04-226
FA-HW-0101-001
PSN-2003-01-063
PSN-2004-11-020
PSN-2008-02-019
Copyright © 2015, Juniper Networks, Inc.
33
M320 Multiservice Edge Router Hardware Guide
NOTE: The memory in
indicates the amount of total memory. To determine the amount of available memory, issue the show chassis routing-engine CLI command.
On routing platforms that accept two Routing Engines, you cannot mix Routing Engine types except for a brief period (one minute or so) during an upgrade or downgrade to two Routing Engines of the same type.
Related
Documentation
•
Supported Routing Engines by Router on page 34
Supported Routing Engines by Router
The following tables list the Routing Engines that each router supports, the first supported release for the Routing Engine in the specified router, the management Ethernet interface, and the internal Ethernet interfaces for each Routing Engine.
•
M7i Routing Engines on page 34
•
M10i Routing Engines on page 35
•
M40e Routing Engines on page 35
•
M120 Routing Engines on page 36
•
M320 Routing Engines on page 36
•
MX104 Routing Engines on page 37
•
MX240 Routing Engines on page 37
•
MX480 Routing Engines on page 38
•
MX960 Routing Engines on page 39
•
MX2010 Routing Engines on page 39
•
MX2020 Routing Engines on page 40
•
PTX3000 Routing Engines on page 40
•
PTX5000 Routing Engines on page 40
•
T320 Routing Engines on page 41
•
T640 Routing Engines on page 41
•
T1600 Routing Engines on page 42
•
T4000 Routing Engines on page 43
•
TX Matrix Routing Engines on page 44
•
TX Matrix Plus Routing Engines on page 44
•
TX Matrix Plus (with 3D SIBs) Routing Engines on page 44
M7i Routing Engines
lists the Routing Engines supported by the M7i router. The M7I router supports 32-bit Junos OS only.
34 Copyright © 2015, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 11: M7i Routing Engines
Model Number
RE-400-768 (EOL details:
TSB16445
)
RE-850-1536
RE-B-1800X1-4G
Name in CLI
Output
RE-5.0
RE-850
RE-B-1800x1
First Supported 32-bit Junos
OS Release
Management
Ethernet
Interface
9.0
fxp0
Internal
Ethernet
Interface fxp1
7.2
11.4R4
12.1R2
fxp0 fxp0 fxp1 em0
M10i Routing Engines
lists the Routing Engines supported by the M10i router. The M10I router supports 32-bit Junos OS only.
Table 12: M10I Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-400-768 (EOL details:
TSB16445
)
RE-5.0
9.0
fxp0
RE-850-1536
RE-B-1800X1-4G
RE-850
RE-B-1800x1
7.2
fxp0 fxp0 fxp1 fxp2 fxp1 fxp2 em0 11.4R4
12.1R2
M40e Routing Engines
lists the Routing Engines supported by the M40e router.
Table 13: M40e Routing Engines
Model Number
Name in CLI
Output
First Supported Junos OS
Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-600-2048 (EOL details:
PSN-2008-02-018 )
RE-3.0
or RE-3.0
(RE-600)
5.3
fxp0
RE-A-1000-2048
RE-A-1000
8.1
fxp0 fxp1 fxp2 fxp1 fxp2
Copyright © 2015, Juniper Networks, Inc.
35
M320 Multiservice Edge Router Hardware Guide
M120 Routing Engines
lists the Routing Engines supported by the M120 router.
Table 14: M120 Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-A-1000-2048
RE-A-1000
8.0R2
– fxp0
RE-A-2000-4096
RE-A-1800x2-8G
RE-A-1800x2-16G
RE-A-1800x4-16G
RE-A-2000
8.0R2
RE-A-1800x2 •
•
11.4R5
12.1R3
RE-A-1800x2
•
•
11.4R5
12.1R3
RE-A-1800x4
•
•
11.4R5
12.1R3
–
10.4
10.4
10.4
fxp0 fxp0 fxp0 fxp0 fxp1 fxp2 em0 em1 fxp1 fxp2 em0 bcm0 fxp1 fxp2
M320 Routing Engines
lists the Routing Engines supported by the M320 router.
Table 15: M320 Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet Interface
Internal
Ethernet
Interface
RE-1600-2048 (EOL details:
PSN-2008-02-019
)
RE-A-2000-4096
RE-4.0
RE-A-2000
6.2
8.1
–
– fxp0 fxp0 fxp1 fxp2
RE-A-1800x2-8G RE-A-1800x2
•
•
11.4R5
12.1R3
10.4
fxp0 em0 bcm0 em0 bcm0
36 Copyright © 2015, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 15: M320 Routing Engines (continued)
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet Interface
Internal
Ethernet
Interface
RE-A-1800x2-16G
RE-A-1800x4-8G
RE-A-1800x2
•
•
11.4R5
12.1R3
RE-A-1800X4
•
•
•
11.4R5
12.1R3
12.2
10.4
10.4
fxp0 fxp0 em0 bcm0 em0 em1
MX104 Routing Engines
lists the Routing Engines supported by MX104 routers.
Table 16: MX104 Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-S-MX104 Routing Engine 13.2
– fxp0 fxp1 fxp2
MX240 Routing Engines
lists the Routing Engines supported by MX240 routers.
Table 17: MX240 Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-S-1300-2048
RE-S-1300
9.0
– fxp0 fxp1 fxp2
RE-S-2000-4096
RE-S-2000
9.0
– fxp0
RE-S-1800x2-8G RE-S-1800x2 •
•
11.4R5
12.1R3
10.4
fxp0 fxp1 fxp2 em0 em1
RE-S-1800x2-16G RE-S-1800X2
•
•
11.4R5
12.1R3
10.4
fxp0 em0 em1
Copyright © 2015, Juniper Networks, Inc.
37
M320 Multiservice Edge Router Hardware Guide
Table 17: MX240 Routing Engines (continued)
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
RE-S-1800x4-8G
RE-S-1800x4-16G
RE-S-1800X4
•
•
11.4R5
12.1R3
RE-S-1800x4
•
•
11.4R5
12.1R3
RE-S-1800X4-32G-S RE-S-1800X4 •
•
12.3R4
13.2R1
10.4
10.4
•
•
12.3R4
13.2R1
fxp0 fxp0 fxp0
Internal Ethernet
Interface em0 em1 em0 em1 em0, em1
MX480 Routing Engines
lists the Routing Engines supported by MX480 routers.
Table 18: MX480 Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-S-1300-2048 RE-S-1300 8.4
– fxp0
RE-S-2000-4096
RE-S-1800x2-8G
RE-S-1800x2-16G
RE-S-1800x4-8G
RE-S-1800x4-16G
RE-S-1800X4-32G-S
RE-S-2000
8.4
RE-S-1800x2
•
•
11.4R5
12.1R3
RE-S-1800X2 •
•
11.4R5
12.1R3
RE-S-1800X4
•
•
11.4R5
12.1R3
RE-S-1800x4
•
•
11.4R5
12.1R3
RE-S-1800X4 •
•
12.3R4
13.2R1
–
10.4
10.4
10.4
10.4
•
•
12.3R4
13.2R1
fxp0 fxp0 fxp0 fxp0 fxp0 fxp0 em0 em1 em0 em1 fxp1 fxp2 fxp1 fxp2 em0 em1 em0 em1 em0 em1
38 Copyright © 2015, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
MX960 Routing Engines
lists the Routing Engines supported by MX960 routers.
Table 19: MX960 Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-S-1300-2048
RE-S-1300
8.2
– fxp0
RE-S-2000-4096
RE-S-1800x2-8G
RE-S-1800x2-16G
RE-S-1800x4-8G
RE-S-1800x4-16G
RE-S-2000
8.2
RE-S-1800x2 •
•
11.4R5
12.1R3
RE-S-1800X2
•
•
11.4R5
12.1R3
RE-S-1800X4
•
•
11.4R5
12.1R3
RE-S-1800x4 •
•
11.4R5
12.1R3
–
10.4
10.4
10.4
10.4
fxp0 fxp0 fxp0 fxp0 fxp0 em0 em1 em0 em1 em0 em1 fxp1 fxp2 fxp1 fxp2 em0 em1
RE-S-1800X4-32G-S RE-S-1800X4
•
•
12.3R4
13.2R1
•
•
12.3R4
13.2R1
fxp0 em0 em1
MX2010 Routing Engines
lists the Routing Engines supported by MX2010 routers.
Table 20: MX2010 Routing Engines
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
MX2000-RE-1800x4
RE-S-1800x4
12.3R2
fxp0 em0 em1
REMX2K-1800-32G-S
RE-S-1800X4
•
•
12.3R4
13.2R1
fxp0 em0 em1
Copyright © 2015, Juniper Networks, Inc.
39
M320 Multiservice Edge Router Hardware Guide
MX2020 Routing Engines
Table 21: MX2020 Routing Engines
Model Number
MX2000-RE-1800x4
REMX2K-1800-32G-S
Name in CLI
Output
RE-S-1800x4
RE-S-1800X4
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
12.3R2
fxp0
•
•
12.3R4
13.2R1
fxp0
Internal
Ethernet
Interface em0 em1 em0 em1
PTX3000 Routing Engines
lists the Routing Engines supported on the PTX3000.
NOTE: The PTX3000 supports 64-bit Junos OS only.
Table 22: PTX3000 Routing Engines
Model Number Name in CLI Output
First Supported Junos
OS Release
RE-DUO-C2600-16G RE-DUO-2600 13.2R2
Management
Ethernet Interface em0
Internal Ethernet
Interface ixgbe0 ixgbe1
PTX5000 Routing Engines
lists the Routing Engines supported on the PTX5000.
NOTE: The PTX5000 supports 64-bit Junos OS only.
Table 23: PTX5000 Routing Engines
Model Number
Name in CLI
Output First Supported Junos OS Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-DUO-C2600-16G
RE-DUO-2600
12.1X48
12.3
13.2
NOTE: The PTX5000 does not support Junos OS Releases 12.1, 12.2, or 13.1.
em0 ixgbe0 ixgbe1
40 Copyright © 2015, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
T320 Routing Engines
lists the Routing Engines supported by the T320 router.
Table 24: T320 Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-600-2048 (EOL details:
PSN-2008-02-018 )
RE-3.0
or RE-3.0
(RE-600)
5.3
fxp0
RE-1600-2048 (EOL details:
PSN-2008-02-019
RE-4.0
RE-A-2000-4096
RE-A-2000
6.2
8.1
fxp0 fxp0 fxp1 fxp2 fxp1 fxp2 fxp1 fxp2
T640 Routing Engines
lists the Routing Engines supported by the T640 router.
Table 25: T640 Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
5.3
– fxp0 fxp1 fxp2
RE-600-2048 (EOL details:
PSN-2008-02-018
)
RE-3.0
RE-3.0
or
(RE-600)
RE-1600-2048 (EOL details:
PSN-2008-02-019 )
RE-4.0
RE-A-2000-4096 RE-A-2000
6.2
8.1
–
– fxp0 fxp0 fxp1 fxp2 em0 bcm0
RE-DUO-C1800-8G RE-DUO-1800 32-bit Junos OS on a standalone T640 router:
11.2
32-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
64-bit Junos OS on a standalone
T640 router: 11.3
64-bit Junos OS on a T640 router in a routing matrix: 11.4R9
em0 bcm0 em1
Copyright © 2015, Juniper Networks, Inc.
41
M320 Multiservice Edge Router Hardware Guide
Table 25: T640 Routing Engines (continued)
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
RE-DUO-C1800-16G
RE-DUO-1800
32-bit Junos OS on a standalone T640 router:
11.4R2
32-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
64-bit Junos OS on a standalone
T640 router:
11.4R2
64-bit Junos OS on a T640 router in a routing matrix: 11.4R9
em0
Internal
Ethernet
Interface bcm0 em1
T1600 Routing Engines
lists the Routing Engines supported by the T1600 router.
NOTE: (Two RE-DUO-C1800-8G or two RE-DUO-C1800-16G are required to connect to a Routing Matrix)
Table 26: T1600 Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
– fxp0 RE-600-2048 (EOL details:
PSN-2008-02-018 )
RE-3.0
or
RE-3.0
(RE-600)
RE-1600-2048 (EOL details:
PSN-2008-02-019 )
RE-4.0
(RE-1600)
RE-A-2000-4096
RE-A-2000
8.5
8.5
8.5
–
– fxp0 fxp0
Internal
Ethernet
Interface fxp1 fxp2 fxp1 fxp2 em0 bcm0
42 Copyright © 2015, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 26: T1600 Routing Engines (continued)
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
RE-DUO-C1800-8G
RE-TXP-LCC or
RE-DUO-1800
32-bit Junos OS on a
T1600 router in a routing matrix: 9.6
NOTE: Junos OS
Releases 9.6 through 10.4
support
RE-DUO-C1800-8G only during upgrade to a line-card chassis (LCC) in a routing matrix.
32-bit Junos OS on a standalone T1600 router:
11.1
64-bit Junos OS on a T1600 router in a routing matrix:
9.6
64-bit Junos OS on a standalone
T1600 router: 11.1
em0
RE-DUO-C1800-16G RE-DUO-1800 32-bit Junos OS on a standalone T1600 router:
11.4R2
32-bit Junos OS on a
T1600 router in a routing matrix: 11.4R2
64-bit Junos OS on a standalone
T1600 router:
11.4R2
64-bit Junos OS on a T1600 router in a routing matrix:
11.4R2
em0
Internal
Ethernet
Interface bcm0 em1 bcm0 em1
T4000 Routing Engines
lists the Routing Engines supported by the T4000 router.
NOTE: The T4000 router supports 64-bit Junos OS only.
Table 27: T4000 Routing Engines
Model Number
RE-DUO-C1800-8G
RE-DUO-C1800-16G
Name in CLI
Output
RE-DUO-1800
RE-DUO-1800
First Supported 64-bit Junos
OS Release
Standalone T4000 router: 12.1
T4000 router in a routing matrix:
13.1
em0
Standalone T4000 router: 12.1R2
em0
T4000 router in a routing matrix:
13.1
Management
Ethernet
Interface
Internal Ethernet
Interface bcm0 em1 bcm0 em1
Copyright © 2015, Juniper Networks, Inc.
43
M320 Multiservice Edge Router Hardware Guide
TX Matrix Routing Engines
lists the Routing Engines supported by the TX Matrix router.
Table 28: TX Matrix Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
7.0
– fxp0 fxp1 fxp2
RE-600-2048 (EOL details:
PSN-2008-02-018
)
RE-3.0
RE-3.0
or
(RE-600)
RE-1600-2048 (EOL details:
PSN-2008-02-019
)
RE-4.0
(RE-1600)
RE-A-2000-4096
RE-A-2000
7.0
8.5
–
– fxp0 fxp0 fxp1 fxp2
RE-DUO-C1800-8G
RE-DUO-1800
11.4R9
11.4R9
em0 em0 bcm0 bcm0 em1
RE-DUO-C1800-16G RE-DUO-1800 11.4R9
11.4R9
em0 bcm0 em1
TX Matrix Plus Routing Engines
lists the Routing Engines supported by the TX Matrix Plus router.
Table 29: TX Matrix Plus Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-DUO-C2600-16G RE-TXP-SFC or
RE-DUO-2600
32-bit Junos OS: 9.6
64-bit Junos OS:
11.4
em0 ixgbe0 ixgbe1
TX Matrix Plus (with 3D SIBs) Routing Engines
lists the Routing Engines supported by the TX Matrix Plus router with 3D SIBs.
44 Copyright © 2015, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 30: Routing Engines on TX Matrix Plus with 3D SIBs
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
RE-DUO-C2600-16G
RE-TXP-SFC or
RE-DUO-2600
64-bit Junos OS:
11.4
em0
Internal
Ethernet
Interface ixgbe0 ixgbe1
Related
Documentation
•
Routing Engine Specifications on page 31
•
Understanding Internal Ethernet Interfaces
•
Understanding Management Ethernet Interfaces
M320 Control Board (CB) Description
Each CB works with an adjacent Routing Engine to provide control and monitoring functions for the router (see
Figure 16 on page 45 ). These functions include determining
Routing Engine mastership, controlling power and reset for the other router components, monitoring and controlling fan speed, and monitoring system status.
You can install one or two CBs in the router. They install into the upper rear of the chassis in the slots labeled CB0 and CB1 (referred to as CB-0 and CB-1, top to bottom) (referred to as CB-0 and CB-1, top to bottom). If two CBs are installed, one functions as the master
CB and the other as its backup. If the master fails or is removed, the backup restarts and becomes the master.
Each CB requires a Routing Engine to be installed in the adjacent slot. CB0 installs above
RE0
, and CB1 installs below RE1. A CB cannot function if a Routing Engine is not present in the adjacent slot.
CBs are hot-pluggable.
Figure 16: CB
Copyright © 2015, Juniper Networks, Inc.
45
M320 Multiservice Edge Router Hardware Guide
Each CB consists of the following components:
•
PCI bus—Provides the interface to the Routing Engine.
•
1000Base-T Ethernet controller—Provides a 1-Gbps link between the Routing Engine and the on-board Fast Ethernet switch.
• Fast Ethernet switch—Provides a 100-Mbps Ethernet link to each FPC for Routing
Engine data transfers.
•
Three LEDs, located on the CB faceplate, indicate the status of the CB.
describes the functions of the CB LEDs.
• CB online/offline button, located on the CB faceplate.
NOTE: When the adjacent Routing Engine is online, the online/offline button on the CB faceplate is nonfunctional. For more information, see
“Taking the M320 Host Subsystem Offline” on page 213 .
•
Circuits that control fans and other hardware components in the chassis.
•
Internally-generated 19.44-MHz Stratum 3 reference clock for line timing.
• Two RJ-48 connectors for external clock inputs for 19.44-MHz Stratum 3 reference clocks.
NOTE: For more information about configuring an interface transmit clock, see the Junos OS Network Interfaces Library for Routing Devices.
NOTE: For more information about configuring the Junos OS to support an external clock synchronization interface, see the Junos OS Administration
Library for Routing Devices.
• Power circuits for the Routing Engine.
Related
Documentation
•
Replacing an M320 Control Board on page 223
•
M320 Routing Engine Description on page 24
M320 Control Board (CB) LEDs
Table 31: M320 CB LEDs
Label Color State
MASTER
FAIL
Blue
Yellow
Description
On steadily Control board is functioning as the master.
On steadily Control board has failed.
46 Copyright © 2015, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 31: M320 CB LEDs (continued)
Label Color State Description
OK Green On steadily Control board is online and is functioning normally.
Blinking Control board is powering up, but not online.
Related
Documentation
•
M320 Chassis Description on page 7
•
M320 Control Board (CB) Description on page 45
•
Replacing an M320 Control Board on page 223
Copyright © 2015, Juniper Networks, Inc.
47
M320 Multiservice Edge Router Hardware Guide
48 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 6
Line Card Components and Descriptions
•
M320 Flexible PIC Concentrator (FPC) Description on page 49
•
M320 FPC Terminology on page 53
•
M320 FPCs Supported on page 53
•
M320 PIC Description on page 54
•
M320 PICs Supported on page 55
•
M320 End-of-Life PICs Supported on page 64
•
M320 PIC Combination Limitations on page 66
•
M320 PIC/FPC Compatibility on page 66
M320 Flexible PIC Concentrator (FPC) Description
Up to eight Flexible PIC Concentrators (FPCs) install vertically in the front of the router
(see
). The FPC slots are numbered left to right from FPC0 to FPC7.
Depending on the FPC type, an FPC has either two or four slots into which a PIC can be installed (see
“M320 FPCs Supported” on page 53
for more information). An FPC can be installed into any FPC slot on the router, regardless of which PICs it contains.
If a slot is not occupied by an FPC, an FPC blank panel must be installed to shield the empty slot and to allow cooling air to circulate properly through the router.
Each FPC consists of the following components:
• FPC card carrier, which includes the PIC slots.
• One Packet Forwarding Engine consisting of Layer 2/Layer 3 Packet Processing ASICs,
Switch Interface ASICs, Internet Processor ASICs, and an MMB, which includes the
Queuing and Memory Interface ASICs.
• Midplane connectors and power circuitry.
• Processor subsystem (PMB), which includes a 288-MHz CPU, system controller, 256 MB of SDRAM, and two Fast Ethernet interfaces.
•
Two LEDs, located on the craft interface above the FPC, that display the status of the
FPC. For more information about the FPC LEDs, see
“M320 Craft Interface FPC LEDs and Online/Offline Buttons” on page 18 .
•
FPC online/offline button, located on the craft interface above the FPC.
Copyright © 2015, Juniper Networks, Inc.
49
M320 Multiservice Edge Router Hardware Guide
The Packet Forwarding Engine receives incoming packets from the PICs installed on the
FPC and forwards them through the switch planes to the appropriate destination port.
Each FPC contains a memory subsystem (MMB) that is managed by the Queuing and
Memory Interface ASICs.
FPCs are hot-removable and hot-insertable, as described in
. When you install an FPC into a functioning router, the Routing Engine downloads the FPC software, the FPC runs its diagnostics, and the PICs, housed on the
FPC, are enabled. Forwarding continues uninterrupted during this process. When you remove or install an FPC, packet forwarding is not affected. For FPC replacement instructions, see
“Replacing an M320 FPC” on page 227
.
Figure 17: FPC Installed in Router Chassis
50
The M320 router supports the following types of FPCs (see
):
• FPC1, Enhanced II FPC1, and Enhanced III FPC1—Rated at 4 gigabits per second (Gbps) full duplex
•
FPC2, Enhanced II FPC2, and Enhanced III FPC2—Rated at 16 Gbps full duplex
Copyright © 2015, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
•
FPC3, Enhanced II FPC3, and Enhanced III FPC3—Rated at 20 Gbps full duplex
Figure 18: FPC1, FPC2, and FPC3 for the M320 Router
shows the Enhanced II FPCs that the M320 router supports.
Copyright © 2015, Juniper Networks, Inc.
51
M320 Multiservice Edge Router Hardware Guide
Figure 19: Enhanced II FPC1, FPC2, and FPC3 for the M320 Router
shows the Enhanced III FPCs that the M320 router supports.
Figure 20: Enhanced III FPC1, FPC2, and FPC3 for the M320 Router
52 Copyright © 2015, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Related
Documentation
•
Maintaining M320 FPCs on page 270
•
•
Troubleshooting the M320 FPCs on page 289
M320 FPC Terminology
Regardless of whether you are holding an FPC vertically or horizontally, this document uses the same terms for all four edges of the FPC (see
• Faceplate—Edge of the FPC that has slots into which you insert the PICs
•
Connector edge—Edge opposite the faceplate; this edge has the connectors that attach to the midplane
• Top edge—Edge at the top of the FPC when it is vertical
• Bottom edge—Edge at the bottom of the FPC when it is vertical
Figure 21: FPC Edges
Related
Documentation
M320 FPCs Supported
lists the FPCs that the M320 router supports. You can install any combination of the following FPCs in the M320 router.
Copyright © 2015, Juniper Networks, Inc.
53
M320 Multiservice Edge Router Hardware Guide
2
2
1
1
2
3
3
3
Table 32: FPCs Supported by the M320 Router
1
FPC Type FPC Name
FPC1
FPC Model Number
M320-FPC1
Maximum
Number of PICs
Supported
4
Maximum
Throughput per FPC
(Full-Duplex)
4 Gbps
First Junos OS
Release
6.2
Enhanced II FPC1 M320-FPC1-E2
Enhanced III FPC1 M320-FPC1-E3
FPC2 M320-FPC2
Enhanced II FPC2 M320-FPC2-E2
Enhanced III FPC2 M320-FPC2-E3
FPC3 M320-FPC3
Enhanced II FPC3 M320-FPC3-E2
Enhanced III FPC3 M320-FPC3-E3
4
4
4
4
4
2
2
2
4 Gbps
4 Gbps
16 Gbps
16 Gbps
16 Gbps
20 Gbps
20 Gbps
20 Gbps
7.5
8.4
6.2
7.5
8.4
6.2
7.5
8.4
Related
Documentation
•
Maintaining M320 FPCs on page 270
•
Replacing an M320 FPC on page 227
•
Troubleshooting the M320 FPCs on page 289
M320 PIC Description
PICs provide the physical connection to various network media types, receiving incoming packets from the network and transmitting outgoing packets to the network. During this process, each PIC performs framing and line-speed signaling for its media type. Before transmitting outgoing data packets, the PICs encapsulate the packets received from the
FPCs. Each PIC is equipped with an ASIC that performs control functions specific to the media type of that PIC.
PICs are hot-removable and hot-insertable. You can install up to four PICs in the slots of each Type 1 and Type 2 FPC, and up to two PICs in the slots of each Type 3 FPC. Type
1 and Type 2 PICs have captive screws at their upper and lower corners. Type 3 PICs have an upper ejector handle and a lower captive screw.
The router supports various PICs, including ATM, Channelized, Gigabit Ethernet, IP Services, and SONET/SDH interfaces. Blank PICs resemble other PICs but do not provide any physical connection or activity. When a slot is not occupied by a PIC, you must insert a blank PIC to fill the empty slot and ensure proper cooling of the system.
Related
Documentation
•
M320 PICs Supported on page 55
54 Copyright © 2015, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
•
M320 End-of-Life PICs Supported on page 64
•
Maintaining M320 PICs and PIC Cables on page 276
•
Replacing an M320 PIC on page 233
•
Troubleshooting the M320 PICs on page 291
M320 PICs Supported
The following tables list the PICs supported by the M320 router. The PICs are listed alphabetically by PIC family.
•
lists the ATM IQ PICs.
•
lists the ATM2 IQ PICs.
•
lists the Channelized PICs.
•
lists the Channelized IQ PICs.
•
lists the Channelized IQE PICs.
•
lists the Circuit Emulation PICs.
•
lists the DS3, E1, E3, and T1 PICs.
•
lists the EIA-530 PIC.
•
lists the Fast Ethernet PICs.
•
lists the Gigabit Ethernet PICs.
•
lists the 10-Gigabit Ethernet PICs.
•
lists the Services PICs.
•
lists the SONET/SDH PICs.
Table 33: ATM IQ PICs Supported by the M320 Router
PIC Family and Type Ports Model Number Connector
First Junos OS
Release
Support
2
ATM OC3 EOL PIC (M320
Router)
ATM OC12 EOL PIC (M320
Router)
1
PB-2OC3-ATM-MM
PB-2OC3-ATM-SMIR
PB-1OC12-ATM-MM
PB-1OC12-ATM-SMIR
• Duplex SC/PC connector (RX and TX)
6.3
• Duplex SC/PC connector (RX and TX)
6.3
Copyright © 2015, Juniper Networks, Inc.
55
M320 Multiservice Edge Router Hardware Guide
Table 34: ATM2 IQ PICs Supported by the M320 Router
PIC Family and Type
ATM2 DS3 IQ PIC (M320
Router)
Ports
4
ATM2 E3 IQ PIC (M320 Router)
4
Model Number
PB-4DS3-ATM2
PB-4E3-ATM2
ATM2 OC3/STM1 IQ PIC (M320
Router)
2
ATM2 OC12/STM4 IQ PICs (M320 Router)
• ATM2 OC12/STM4 IQ PIC 1 PB-1OC12-ATM2-MM
PB-1OC12-ATM2-SMIR
• ATM2 OC12/STM4 IQ PIC 2
PB-2OC3-ATM2-MM
PB-2OC3-ATM2-SMIR
ATM2 OC48/STM16 IQ PIC with
SFP (M320 Router)
1
PB-2OC12-ATM2-MM
PB-2OC12-ATM2-SMIR
PB-1OC48-ATM2-SFP
Connector
First Junos OS
Release
Support
Coaxial:
•
•
10 ft (3.05 m) posilock SMB to BNC (provided)
Four pairs of Rx and Tx coaxial cables
6.4
Coaxial:
•
•
10 ft (3.05 m) posilock SMB to BNC cable (provided)
Four pairs of Rx and Tx coaxial cables
6.3
• Optical: SC/PC 6.2
• Optical: SC/PC
• Optical: SC/PC
• Optical: LC/PC
6.2
6.2
7.3
Table 35: Channelized PICs Supported by the M320 Router
PIC Family and Type
Channelized DS3 EOL PIC
(M320 Router)
Channelized OC12 EOL PIC
(M320 Router)
Multichannel DS3 EOL PIC
(M320 Router)
Ports
4
1
2
Model Number
PB-4CHDS3
PB-1CHOC12DS3-SMIR
PB-2MCDS3
Connector
First Junos OS
Release
Support
•
Custom 10-ft (3.05-m) posilock to BNC male cable, separate RX and TX
6.3
•
Duplex SC/PC connector (RX and TX)
6.3
•
Custom 10 ft/3.05 m posilock to BNC male cable, separate
Rx and Tx
6.2
56 Copyright © 2015, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 36: Channelized IQ PICs Supported by the M320 Router
PIC Family and Type Ports
Channelized DS3 IQ PIC (M320
Router)
4
Channelized E1 IQ PIC (M320
Router)
10
Channelized OC3 IQ PIC (M320
Router)
1
Channelized OC12 IQ EOL PIC
(M320 Router)
1
Channelized STM1 IQ PIC
(M320 Router)
Channelized T1 IQ PIC (M320
Router)
1
10
Model Number
PB-4CHDS3-QPP
PB-10CHE1-RJ48-QPP-N
PB-1CHOC3-SMIR-QPP
PB-1CHOC12SMIR-QPP
PB-1CHSTM1-SMIR-QPP
PB-10CHT1-RJ48-QPP
Connector
Coaxial
• Standard DS3 BNC coaxial cable interfaces
• 120-ohm RJ-48C
• Optical: SC/PC
First Junos OS
Release
Support
6.2
9.1R4
9.2R3
9.3R1
7.1
• Duplex SC/PC connector (Rx and Tx); single-mode fiber
6.2
• Optical: SC/PC 6.2
• 120-ohm RJ-48C connector
(female)
7.4
Table 37: Channelized IQE PICs Supported by the M320 Router
PIC Family and Type Ports Model Number Connector
First Junos OS
Release
Support
Channelized DS3/E3 Enhanced
IQ (IQE) PIC (M320 Router)
4
Channelized E1/T1 Enhanced IQ
(IQE) PIC (M320 Router)
10
Channelized OC3/STM1
Enhanced IQ (IQE) PIC with
SFP (M320 Router)
2
PB-4CHDS3-E3-IQE-BNC
PB-10CHE1-T1-IQE-RJ48
Coaxial
•
Standard DS3 BNC coaxial cable interfaces
9.3
•
120-ohm RJ-48C connector
(female)
9.5
PB-2CHOC3-STM1-IQE-SFP
•
Optical: LC/PC
Channelized OC12/STM4 Enhanced IQ (IQE) PIC with SFP (M320 Router)
PB-1CHOC12-STM4-IQE-SFP
•
Optical: LC/PC
•
Channelized OC12/STM4
Enhanced IQ (IQE) PIC with
SFP
1
•
Channelized OC12/STM4
Enhanced IQ (IQE) PIC with
SFP
4 PB-4CHOC12-STM4-IQE-SFP
•
Optical: LC/PC
9.3
9.3
9.4
Copyright © 2015, Juniper Networks, Inc.
57
M320 Multiservice Edge Router Hardware Guide
Table 37: Channelized IQE PICs Supported by the M320 Router (continued)
PIC Family and Type
Channelized OC48/STM16
Enhanced IQ (IQE) PIC with
SFP (M320 Router)
1
Ports Model Number Connector
PB-1CHOC48-STM16-IQE-SFP • Optical: LC/PC
First Junos OS
Release
Support
9.4
Table 38: Circuit Emulation PICs Supported by the M320 Router
PIC Family and Type Ports
Channelized OC3/STM1 Circuit
Emulation PIC with SFP (M320
Router)
4
E1/T1 Circuit Emulation PIC
(M320 Router)
12
Model Number
PB-4CHOC3-CE-SFP
PB-12T1E1-CE-TELCO
Connector
•
Optical: LC/PC
First Junos OS
Release
Support
9.4
•
•
RJ-21 connector
Cables are rated for intra-building connections only.
9.4
Table 39: DS3, E1, E3, and T1 PICs Supported by the M320 Router
PIC Family and Type Ports
DS3/E3 Enhanced IQ (IQE) PIC
(M320 Router)
4
DS3 EOL PIC (M320 Router)
E1 PICs (M320 Router)
E3 PIC (M320 Router)
E3 IQ PIC (M320 Router)
4
4
4
4
Model Number
PB-4DS3-E3-IQE-BNC
PB-2DS3
PB-4E1-COAX
PB-4E1-RJ48
PB-4E3-QPP
PB-4E3-QPP
Connector
First Junos OS
Release
Support
Coaxial
• Standard DS3 BNC coaxial cable interfaces
• Custom 10-ft (3.05-m) posilock SMB to BNC male cable, separate Rx and Tx
(provided)
9.3R2
6.2
•
•
Four RJ-48 connectors (one per port)
Four coaxial connectors
Custom 10-ft (3.05-m) posilock to BNC male cable, separate Rx and Tx
6.4
• Custom 10 ft (3.05 m) posilock to BNC male cable, separate RX and TX
6.3
Coaxial
• Standard DS3 BNC coaxial cable interfaces
6.2
58 Copyright © 2015, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 39: DS3, E1, E3, and T1 PICs Supported by the M320 Router (continued)
PIC Family and Type
T1 PIC (M320 Router)
Ports
4
Model Number
PB-4T1-RJ48
Connector
• 100-ohm RJ-48 connector
First Junos OS
Release
Support
6.4
Table 40: EIA-530 PIC Supported by the M320 Router
PIC Family and Type
EIA-530 PIC (M320 Router)
Ports
2
Model Number
PB-2EIA530
Connector
First Junos OS
Release
Support
•
•
•
Two DB-25 male connectors
(one per port, included with
PIC)
V.35 requires an EIA-530 to
V.35 cable and connects to a V.35 DTE 34-pin
Winchester type male cable
(one per port)
X.21 requires an EIA-530 to
X.21 cable and connects to a
X.21 DTE DB-15 male cable
6.2
Table 41: Fast Ethernet PICs Supported by the M320 Router
Model Number Connector
First Junos OS
Release
Support PIC Family and Type Ports
Fast Ethernet PICs (M320 Router)
• Fast Ethernet PIC 4 PB-4FE-TX
• Fast Ethernet PIC
• Fast Ethernet PIC
• Fast Ethernet PIC
8
12
48
PB-8FE-FX
PB-12FE-TX-MDI
PB-12FE-TX-MDIX
PB-48FE-TX
•
•
RJ-45
Two-pair, Category 5 unshielded twisted-pair
• Pinout: MDI noncrossover
• MT-RJ female
6.2
6.3
• One very high density connector interface (VHDCI) to RJ-21 cable that connects to an RJ-45 patch panel
6.2
• Four VHDCI connectors
VHDCI-to-RJ-21 cables that connect to an RJ-45 patch panel
6.4
Copyright © 2015, Juniper Networks, Inc.
59
M320 Multiservice Edge Router Hardware Guide
Table 42: Gigabit Ethernet PICs Supported by the M320 Router
Connector PIC Family and Type Ports Model Number
Gigabit Ethernet
Gigabit Ethernet PICs with SFP (M320 Router)
• Gigabit Ethernet PIC with
SFP
1 PB-1GE-SFP
• Gigabit Ethernet PIC with
SFP
2
• Gigabit Ethernet PIC with
SFP
4
• Gigabit Ethernet PIC with
SFP
10
PB-2GE-SFP
PB-4GE-SFP
PC-10GE-SFP
First Junos OS
Release
Support
•
•
Optical: LC/PC
Copper: RJ-45
•
•
Four-pair, Category 5 shielded twisted-pair connectivity
Pinout: MDI crossover
•
•
Optical: LC/PC
Copper: RJ-45
• Four-pair, Category 5 shielded twisted-pair connectivity
•
•
Optical: LC/PC
Copper: RJ-45
• Four-pair, Category 5 shielded twisted-pair connectivity
•
•
Optical: LC/PC
Copper: RJ-45
• Four-pair, Category 5 shielded twisted-pair connectivity
6.4
6.4
7.0
6.2
Gigabit Ethernet IQ
Gigabit Ethernet IQ PICs with SFP (M320 Router)
•
Gigabit Ethernet IQ PIC with SFP
1 PB-1GE-SFP-QPP
•
•
Optical: LC/PC
Copper: RJ-45
•
•
Four-pair, Category 5 shielded twisted-pair connectivity
Pinout: MDI crossover
6.2
60 Copyright © 2015, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 42: Gigabit Ethernet PICs Supported by the M320 Router (continued)
PIC Family and Type
• Gigabit Ethernet IQ PIC with SFP
Ports
2
Model Number
PB-2GE-SFP-QPP
Connector
•
•
Optical: LC/PC
Copper: RJ-45
•
•
Four-pair, Category 5 shielded twisted-pair connectivity
Pinout: MDI crossover
Gigabit Ethernet IQ2
Gigabit Ethernet IQ2 PICs with SFP (M320 Router)
• Gigabit Ethernet IQ2 PIC with SFP
4
• Gigabit Ethernet IQ2 PIC with SFP
8
• Gigabit Ethernet IQ2 PIC with SFP
8
PB-4GE-TYPE1-SFP-IQ2
PB-8GE-TYPE2-SFP-IQ2
PC-8GE-TYPE3-SFP-IQ2
•
•
Optical: LC/PC
Copper: RJ-45
• Four-pair, Category 5 shielded twisted-pair connectivity
•
•
Optical: LC/PC
Copper: RJ-45
• Four-pair, Category 5 shielded twisted-pair connectivity
•
•
Optical: LC/PC
Copper: RJ-45
• Four-pair, Category 5 shielded twisted-pair connectivity
Gigabit Ethernet IQ2E
Gigabit Ethernet Enhanced IQ2 (IQ2E) PICs with SFP (M320 Router)
•
Type 1 Gigabit Ethernet
Enhanced IQ2 (IQ2E) PIC with SFP
4 PB-4GE-TYPE1-SFP-IQ2E
•
•
Optical: LC/PC
Copper: RJ-45
•
Four-pair, Category 5 shielded twisted-pair connectivity
•
Type 2 Gigabit Ethernet
Enhanced IQ2 (IQ2E) PIC with SFP
8 PB-8GE-TYPE2-SFP-IQ2E
•
•
Optical: LC/PC
Copper: RJ-45
•
Four-pair, Category 5 shielded twisted-pair connectivity
First Junos OS
Release
Support
6.2
7.6R3
7.6R2
8.2
9.4
9.4
Copyright © 2015, Juniper Networks, Inc.
61
M320 Multiservice Edge Router Hardware Guide
Table 42: Gigabit Ethernet PICs Supported by the M320 Router (continued)
PIC Family and Type Ports
• Type 3 Gigabit Ethernet
Enhanced IQ2 (IQ2E) PIC with SFP
8
Model Number Connector
PC-8GE-TYPE3-SFP-IQ2E •
•
Optical: LC/PC
Copper: RJ-45
• Four-pair, Category 5 shielded twisted-pair connectivity
Table 43: 10-Gigabit Ethernet PICs Supported by the M320 Router
PIC Family and Type
10-Gigabit Ethernet PIC with
XENPAK (M320 Router)
1
1
10-Gigabit Ethernet DWDM
PIC (M320 Router)
10-Gigabit Ethernet IQ2 PIC with XFP (M320 Router)
1
10-Gigabit Ethernet Enhanced
IQ2 (IQ2E) PIC with XFP
(M320 Router)
1
Ports Model Number
PC-1XGE-XENPAK
Connector
• XENPAK
PC-1XGE-DWDM-CBAND • Optical: SC/PC
PC-1XGE-TYPE3–XFP-IQ2 • Optical: LC/PC
PC-1XGE-TYPE3–XFP-IQ2E • Optical: LC/PC
Table 44: Service PICs Supported by the M320 Router
PIC Family and Type Ports
Multiservices PICs (M320 Router)
• 100 Multiservices PIC
• 400 Multiservices PIC
0
0
• 500 Multiservices PIC 0
Tunnel Services PIC (M320 Router)
• Type 1 Tunnel Services PIC 0
• Type 2 Tunnel Services PIC 0
• Type 3 Tunnel Services PIC 0
Model Number
PB-MS-100-1
PB-MS-400-2
PB-MS-500-3
PB-TUNNEL-1
PB-TUNNEL
PC-TUNNEL
Connector
• None
• None
• None
• None
• None
• None
First Junos OS
Release
Support
9.4
First Junos OS
Release Support
6.2
7.5
8.0R3
9.4
First Junos OS
Release Support
6.2
6.2
6.3
8.1
8.1R2
8.3
62 Copyright © 2015, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 45: SONET/SDH PICs Supported by the M320 Router
PIC Family and Type Ports Model Number Connector
First Junos OS
Release
Support
SONET/SDH
SONET/SDH OC3/STM1 Enhanced IQ
(IQE) PIC with SFP (M320 Router)
4 PB-4OC3-STM1-IQE-SFP • Optical: LC/PC 9.3R2
SONET/SDH OC3/STM1 (Multi-Rate) PICs with SFP (M320 Router)
PB-4OC3-1OC12-SON-SFP • Optical: LC/PC • SONET/SDH OC3/STM1 (Multi-Rate)
PIC with SFP
4
• SONET/SDH OC3/STM1 (Multi-Rate)
PIC with SFP
SONET/SDH OC12/STM4 Enhanced IQ
(IQE) PIC with SFP (M320 Router)
4
1
PB-4OC3-1OC12-SON2-SFP
PB-1OC12-STM4-IQE-SFP
•
•
Optical: LC/PC
Optical: LC/PC
SONET/SDH OC12/STM4 (Multi-Rate) PICs with SFP (M320 Router)
PB-1OC12-SON-SFP • SONET/SDH OC12/STM4 (Multi-Rate)
PIC with SFP
1
• SONET/SDH OC12/STM4 (Multi-Rate)
PIC with SFP
4
SONET/SDH OC48c/STM16 PICs with SFP
(M320 Router)
4
PB-4OC3-4OC12-SON-SFP
PC-4OC48-SON-SFP
•
• Optical: LC/PC
•
Optical: LC/PC
Optical: LC/PC
SONET/SDH OC48/STM16 Enhanced IQ
(IQE) PIC with SFP (M320 Router)
4 PC-4OC48-STM16-IQE-SFP • Optical: LC/PC
PB-1OC48-SON-B-SFP • Optical: LC/PC
SONET/SDH OC48/STM16 (Multi-Rate)
PIC with SFP (M320 Router)
1
SONET/SDH OC192c/STM64 PIC (M320
Router)
1
SONET/SDH OC192/STM64 PIC with XFP
(M320 Router)
1
PC-1OC192-SON-VSR
PC-1OC192-SON-XFP
• 12-ribbon multimode fiber with MTP connector
• Optical: LC/PC
8.4
8.3
9.3
8.4
8.3
6.2
10.4R2
8.3
6.2
8.1
Related
Documentation
•
M320 PIC Description on page 54
•
M320 PIC Combination Limitations on page 66
•
M320 FPCs Supported on page 53
•
M320 PIC/FPC Compatibility on page 66
Copyright © 2015, Juniper Networks, Inc.
63
M320 Multiservice Edge Router Hardware Guide
M320 End-of-Life PICs Supported
lists the end-of-life PICs supported by the M320 router. The PICs are listed alphabetically by PIC family.
Table 46: End-of-Life PICs Supported in the M320 Router
PIC Family and Type Ports Model Number Connector
First Junos OS
Release
Support
ATM
ATM OC3 EOL PIC (M320 Router)
2 6.3
ATM OC12 EOL PIC (M320 Router)
1
PB-2OC3-ATM-MM
PB-2OC3-ATM-SMIR
PB-1OC12-ATM-MM
PB-1OC12-ATM-SMIR
6.3
Channelized
Channelized DS3 EOL PIC (M320
Router)
Channelized OC12 EOL PIC (M320
Router)
Multichannel DS3 EOL PIC (M320
Router)
4
1
2
Channelized IQ
Channelized E1 IQ EOL PIC (M320
Router)
Channelized OC12 IQ EOL PIC (M320
Router)
1
10
DS3
DS3 EOL PIC (M320 Router)
Ethernet
Gigabit Ethernet EOL PICs (M320
Router)
4
1
PB-4CHDS3
PB-1CHOC12DS3-SMIR
PB-2MCDS3
PB-10CHE1-RJ48-QPP
PB-1CHOC12SMIR-QPP
PB-2DS3
PB-1GE-LH
PB-1GE-LX
PB-1GE-SX
6.3
6.3
6.2
6.2
6.2
6.2
6.2
Gigabit Ethernet EOL PICs (M320
Router)
• Gigabit Ethernet PIC 2 6.2
• Gigabit Ethernet PIC 4
PB-2GE-LX
PB-2GE-SX
PB-4GE-SX 6.2
64 Copyright © 2015, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 46: End-of-Life PICs Supported in the M320 Router (continued)
PIC Family and Type
10-Gigabit Ethernet EOL PIC (M320
Router)
Services
Adaptive Services II EOL PIC (M320
Router)
0
Adaptive Services II Layer 2 Services
EOL PIC (M320 Router)
Adaptive Services II FIPS EOL PIC
(M320 Router)
ES EOL PIC (M320 Router)
0
0
0
Link Services EOL PIC (M320 Router)
0
1
Ports Model Number
PC-1XGE-LR
PB-AS2
PB-AS2-LAYER2SERVICES
PB-AS2-FIPS
PB-ES-800
PB-LS-4
PB-LS-32
PB-LS-128
PB-PM2
Monitoring Services II EOL PIC (M320
Router)
0
Monitoring Services III EOL PIC (M320
Router)
0
SONET/SDH
SONET/SDH OC3c/STM1 EOL PICs
(M320 Router)
4
SONET/SDH OC12c/STM4 EOL PICs
(M320 Router)
•
SONET/SDH OC12c/STM4 PIC
•
SONET/SDH OC12c/STM4 PIC
1
4
PB-PM3
PB-4OC3-SON-MM
PB-4OC3-SON-SMIR
PB-1OC12-SON-MM
PB-4OC12-SON-MM
PB-4OC12-SON-SMIR
SONET/SDH OC48c/STM16 EOL PICs
(M320 Router)
•
SONET/SDH OC48c/STM16 PIC 1
•
SONET/SDH OC48c/STM16 PIC 4
SONET/SDH OC48c/STM16 EOL PIC with SFP (M320 Router)
1
PB-1OC48-SON-SMLR
PB-1OC48-SON-SMSR
PC-4OC48-SON-SMSR
PB-1OC48-SON-SFP
Connector
• None
• None
• None
• None
• None
• None
• None
Copyright © 2015, Juniper Networks, Inc.
7.2
6.2
6.2
6.4
7.5
6.0
7.4
6.2
First Junos OS
Release
Support
6.2
6.2
6.2
6.2
6.2
6.2
65
M320 Multiservice Edge Router Hardware Guide
Table 46: End-of-Life PICs Supported in the M320 Router (continued)
PIC Family and Type
SONET/SDH OC192c/STM64 EOL
PICs (M320 Router)
1
Ports Model Number
PC-1OC192-SON-LR
PC-1OC192-SON-SR2
Connector
First Junos OS
Release
Support
5.4
Related
Documentation
•
M320 PIC Description on page 54
M320 PIC Combination Limitations
In most cases, you can install PICs of different media types on the same FPC as long as the FPC and the router support those PICs. However, configuration rules might limit certain combinations of PICs on some platforms.
Newer Junos OS services for some PICs can require significant Internet Processor ASIC memory. Ethernet and SONET PICs typically do not use large amounts of memory. Gigabit
Ethernet, ATM2, IQ serial PICs, and Multiservices PICs use more. To conserve memory, you can group PICs in the same family together on the same FPC.
If you have different PIC families on a single FPC, review the configuration rules to plan which PICs to install on the FPCs for your router. Consult technical bulletin
PSN-2007-01-023 for information about configuration rules for PIC combinations on the
Juniper Networks Support site at https://www.juniper.net/alerts/ .
When you upgrade to Junos OS Release 7.5 or later, a warning appears if any configuration rules affect your PIC combinations. If you continue the installation, one or more PICs might appear to be online (the LEDs are on), but the Junos OS cannot enable them and they cannot pass traffic. As a workaround, you can:
• Install a Junos OS release that supports the combination.
•
Install PICs on a different FPC.
•
Remove PICs from the affected FPC.
Related
Documentation
•
M320 PIC Description on page 54
•
M320 PICs Supported on page 55
•
M320 FPCs Supported on page 53
•
M320 PIC/FPC Compatibility on page 66
M320 PIC/FPC Compatibility
The PIC/FPC compatibility matrixes list the first Junos OS Release in which an FPC supports each PIC currently supported for the M320 router. For example, Junos OS Release
7.5 is the first release in which the E-II-FPC1 supports the ATM2 OC3/STM1 IQ, 2-port PIC.
66 Copyright © 2015, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
NOTE: A – indicates that the PIC is not supported by the FPC.
•
PIC/FPC Compatibility (Type 1 FPCs and Type 1 PICs) on page 67
•
PIC/FPC Compatibility (Type 2 FPCs and Type 2 PICs) on page 70
•
PIC/FPC Compatibility (Type 3 FPCs and Type 3 PICs) on page 71
PIC/FPC Compatibility (Type 1 FPCs and Type 1 PICs)
provides a PIC/FPC compatibility matrix for the current Type 1 PICs for the M320 router and Type 1 FPCs. A link to the PIC description is included in the table.
Table 47: M320 PIC/FPC Compatibility Type 1
PIC PIC Model Number FPC1 E-II FPC1 E-III FPC1
ATM2 IQ PICs
ATM2 DS3 IQ PIC (M320 Router)
4-port
ATM2 E3 IQ PIC (M320 Router)
4-port
PB-4DS3-ATM2
PB-4E3-ATM2
ATM2 OC3/STM1 IQ PIC (M320 Router)
2-port
PB-2OC3-ATM2-MM
PB-2OC3-ATM2-SMIR
ATM2 OC12/STM4 IQ PICs (M320
Router)
1-port
PB-1OC12-ATM2-MM
PB-1OC12-ATM2-SMIR
PB-1OC12-ATM2-MM
Channelized Circuit Emulation PICs
Channelized OC3/STM1 Circuit
Emulation PIC with SFP (M320 Router)
PB-4CHOC3-CE-SFP
Channelized IQ PICs
Channelized DS3 IQ PIC (M320 Router)
4-port
PB-4CHDS3-QPP
Channelized E1 IQ PIC (M320 Router)
10-port
PB-1OCHE1-RJ48-QPP-N
Channelized OC3 IQ PIC (M320 Router)
1-port
PB-1CHOC3-SMIR-QPP
6.4
6.3
6.2
6.2
6.2
6.2
6.2
–
6.2
9.1R4
9.2R3
9.3R1
7.1
7.5
7.5
–
7.5
9.1R4
9.2R3
9.3R1
7.5
7.5
7.5
7.5
7.5
7.5
8.4
8.4
9.1R4
9.2R3
9.3R1
8.4
8.4
8.4
8.4
8.4
8.4
9.4
8.4
Copyright © 2015, Juniper Networks, Inc.
67
M320 Multiservice Edge Router Hardware Guide
Table 47: M320 PIC/FPC Compatibility Type 1 (continued)
PIC PIC Model Number
Channelized STM1 IQ PIC (M320
Router)
1-port
PB-1CHSTM1-SMIR-QPP
Channelized T1 IQ PIC (M320 Router)
10-port
PB-1OCHT1-RJ48-QPP
Channelized Enhanced IQ (IQE) PICs
Channelized DS3/E3 Enhanced IQ
(IQE) PIC (M320 Router)
4-port
PB-4CHDS3-E3–IQE-BNC
Channelized E1/T1 Enhanced IQ (IQE)
PIC (M320 Router) 10-port
PB-10CHE1-T1-IQE-RJ48
Channelized OC3/STM1 Enhanced IQ
(IQE) PIC with SFP (M320 Router)
2-port
PB-2CHOC3-STM1-IQE-SFP
Channelized OC12/STM4 Enhanced IQ
(IQE) PIC with SFP (M320 Router) IQE,
1-port
PB-1CHOC12-STM4-IQE-SFP
T1, DS3, E1, E3 PICs
DS3 EOL PIC (M320 Router),
4-port
PB-4DS3
DS3/E3 Enhanced IQ (IQE) PIC (M320
Router)
4-port
PB-4DS3-E3-IQE-BNC
E1 PICs (M320 Router),
4-port
PB-4E1-COAX
PB-4E1-RJ48
E1/T1 Circuit Emulation PIC (M320
Router), 12-port
E3 PIC (M320 Router),
4-port
T1 PIC (M320 Router),
4-port
PB-12T1E1-CE-TELCO
PB-4E3
PB-4T1-RJ48
E3 IQ PIC
E3 IQ PIC (M320 Router),
4-port
EIA-530 PIC
PB-4E3-QPP
FPC1
6.2
E-II FPC1
7.5
E-III FPC1
8.4
7.4
–
–
–
–
–
–
6.4
6.4
–
6.3
6.4
6.2
7.5
9.3
9.5
9.3
9.3
6.2
9.3R2
7.5
7.5
–
7.5
7.5
7.5
8.4
9.3
9.5
9.3
9.3
–
9.3R2
8.4
8.4
9.4
–
8.4
8.4
68 Copyright © 2015, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 47: M320 PIC/FPC Compatibility Type 1 (continued)
PIC PIC Model Number
EIA-530 PIC (M320 Router),
2-port
PB-2EIA530
Ethernet PICs
Fast Ethernet PICs (M320 Router),
4-port
PB-4FE-TX
Fast Ethernet PICs (M320 Router),
8-port
Fast Ethernet PICs (M320 Router),
12-port
PB-8FE-FX
PB-12FE-TX
Gigabit Ethernet PICs with SFP (M320
Router),
1-port SFP
PB-1GE-SFP
Ethernet IQ PICs
Gigabit Ethernet IQ PICs with SFP
(M320 Router),
1-port SFP
Ethernet IQ2 PICs
Gigabit Ethernet IQ2 PICs with SFP
(M320 Router),
4-port SFP
PB-1GE-SFP-QPP
PB-4GE-TYPE1-SFP-IQ2
Ethernet Enhanced IQ2 (IQ2E) PICs
Gigabit Ethernet Enhanced IQ2 (IQ2E)
PICs with SFP (M320 Router),
4-port SFP
PB-4GE-TYPE1-SFP-IQ2E
Services PICs
Multiservices PICs (M320 Router) 100 PB-MS-100-1
Tunnel Services PIC (M320 Router)
PB-TUNNEL-1
SONET/SDH PICs
SONET/SDH OC3/STM1 Enhanced IQ
(IQE) PIC with SFP (M320 Router)
4-port, SFP
PB-4OC3-STM1-IQE-SFP
SONET/SDH OC3/STM1 (Multi-Rate)
PICs with SFP (M320 Router),
4-port, SFP (Type 1)
PB-4OC3-1OC12-SON-SFP
FPC1
6.2
E-II FPC1
7.5
E-III FPC1
8.4
6.2
6.3
6.2
6.4
6.2
7.6R3
7.6R3
9.4
8.1
6.2
–
8.4
7.5
7.5
7.5
7.5
7.5
9.4
8.1
7.5
9.3R2
8.4
8.4
8.4
8.4
8.4
8.4
8.4
9.4
8.4
8.4
9.3R2
8.4
Copyright © 2015, Juniper Networks, Inc.
69
M320 Multiservice Edge Router Hardware Guide
Table 47: M320 PIC/FPC Compatibility Type 1 (continued)
PIC PIC Model Number
SONET/SDH OC12/STM4 Enhanced IQ
(IQE) PIC with SFP (M320 Router),
1-port, SFP
PB-1OC12-STM4-IQE-SFP
SONET/SDH OC12/STM4 (Multi-Rate)
PICs with SFP (M320 Router)),
1-port, SFP
PB-1OC12-SON-SFP
FPC1
–
E-II FPC1
9.3
E-III FPC1
9.3
8.4
8.4
8.4
PIC/FPC Compatibility (Type 2 FPCs and Type 2 PICs)
provides a PIC/FPC compatibility matrix for the current Type 2 PICs for the M320 router and Type 2 FPCs. A link to the PIC description is included in the table.
Table 48: M320 PIC/FPC Compatibility Type 2
PIC Model Number FPC2 E-II FPC2 E-III-FPC2
ATM2 IQ PICs
ATM2 OC12/STM4 IQ PICs (M320
Router) 2-port
PB-2OC12-ATM2-MM
PB-2OC12-ATM2-SMIR
ATM2 OC12/STM4 IQ PICs (M320 Router)
ATM2 OC48/STM16 IQ PIC with
SFP (M320 Router) 1-port
PB-1OC48-ATM2-SFP
Channelized Enhanced IQ (IQE) PICs
Channelized OC12/STM4
Enhanced IQ (IQE) PIC with SFP
(M320 Router) 4-port
PB-4CHOC12-STM4-IQE-SFP
Channelized OC48/STM16
Enhanced IQ (IQE) PIC with SFP
(M320 Router) 1-port
PB-1CHOC48-STM16-IQE
Ethernet PICs
Fast Ethernet PICs (M320 Router)
48-port
PB-48FE-TX
PB-2GE-SFP
Gigabit Ethernet PICs with SFP
(M320 Router) 2-port
Gigabit Ethernet PICs with SFP
(M320 Router) 4-port
PB-4GE-SFP
Ethernet IQ PICs
Gigabit Ethernet IQ PICs with SFP
(M320 Router) 2-port
PB-2GE-SFP-QPP
6.2
6.2
7.3
–
–
6.4
6.4
7.0
6.2
7.5
7.5
7.5
–
–
7.5
7.5
7.5
7.5
8.4
8.4
8.4
9.4
9.4
8.4
8.4
8.4
8.4
70 Copyright © 2015, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 48: M320 PIC/FPC Compatibility Type 2 (continued)
PIC Model Number
Ethernet IQ2 PICs
Gigabit Ethernet IQ2 PICs with
SFP (M320 Router) 8-port
PB-8GE-TYPE2-SFP-IQ2
Ethernet Enhanced IQ2 (IQ2E) PICs
Gigabit Ethernet Enhanced IQ2
(IQ2E) PICs with SFP (M320
Router) 8-port
PB-8GE-TYPE2-SFP-IQ2E
Services PICs
Multiservices PICs (M320 Router)
400
PB-MS-400-2
Tunnel Services PIC (M320
Router)
PB-TUNNEL
SONET/SDH PICs
SONET/SDH OC3/STM1
(Multi-Rate) PICs with SFP
(M320 Router) 4-port
SONET/SDH OC12/STM4
(Multi-Rate) PICs with SFP
(M320 Router) 4-port
PB-4OC3-1OC12-SON2-SFP
PB-4OC3-4OC12-SON-SFP
SONET/SDH OC48/STM16
(Multi-Rate) PIC with SFP (M320
Router) 1-port
PB-1OC48-SON-B-SFP
FPC2 E-II FPC2
7.6R2
9.4
8.1R2
6.3
8.3
8.3
8.3
7.6R2
9.4
8.1R2
7.5
8.3
8.3
8.3
E-III-FPC2
8.4
9.4
8.4
8.4
8.4
8.4
8.4
PIC/FPC Compatibility (Type 3 FPCs and Type 3 PICs)
provides a PIC/FPC compatibility matrix for the current Type 3 PICs for the M320 router and Type 3 FPCs. A link to the PIC description is included in the table.
Table 49: M320 PIC/FPC Compatibility Type 3
PIC Model Number FPC3 E-II-FPC3 E-III-FPC3
Ethernet PICs
Gigabit Ethernet PICs with SFP
(M320 Router) 10-port
10-Gigabit Ethernet PICs
10-Gigabit Ethernet PIC with
XENPAK (M320 Router) 1–port
10-Gigabit Ethernet DWDM PIC
(M320 Router) 1–port
PC-10GE-SFP
PC-1XGE-XENPAK
PC-1XGE-DWDM-CBAND
6.2
6.2
7.5
7.5
7.5
7.5
8.4
8.4
8.4
Copyright © 2015, Juniper Networks, Inc.
71
M320 Multiservice Edge Router Hardware Guide
Table 49: M320 PIC/FPC Compatibility Type 3 (continued)
PIC Model Number
Ethernet IQ2 PICs
Gigabit Ethernet IQ2 PICs with SFP
(M320 Router) 8–port
PC-8GE-TYPE3-SFP-IQ2
Gigabit Ethernet IQ2 PICs with SFP
(M320 Router) 1–port
PC-1GE-TYPE3-XFP-IQ2
Ethernet Enhanced IQ2 (IQ2E) PICs
Gigabit Ethernet Enhanced IQ2
(IQ2E) PICs with SFP (M320
Router) 8-port
PC-8GE-TYPE3-SFP-IQ2E
10-Gigabit Ethernet Enhanced IQ2
(IQ2E) PIC with XFP (M320
Router) 1-port
PC-1XGE-TYPE3-XFP-IQ2E
Services PICs
Multiservices PICs (M320 Router)
500
PC-MS-500-3
Tunnel Services PIC (M320 Router)
PC-TUNNEL
SONET/SDH PICs
SONET/SDH OC48/STM16
Enhanced IQ (IQE) PIC with SFP
(M320 Router) 4-port
PC-4OC48-STM16-IQE-SFP
SONET/SDH OC48c/STM16 PICs
with SFP (M320 Router) 4-port
PC-4OC48-SON-SFP
SONET/SDH OC192c/STM64 PIC
(M320 Router) 1-port
PC-1OC192-SON-VSR
SONET/SDH OC192/STM64 PIC
with XFP (M320 Router) 1-port
PC-1OC192-SON-SFP
Related
Documentation
•
M320 PIC Description on page 54
•
M320 PIC Combination Limitations on page 66
•
M320 PICs Supported on page 55
•
M320 FPCs Supported on page 53
FPC3
8.2
8.0R3
9.4
9.4
8.3
6.3
–
6.2
6.2
8.1
E-II-FPC3 E-III-FPC3
8.2
8.0R3
9.4
9.4
8.3
7.5
–
7.5
7.5
8.1
8.4
8.4
9.4
9.4
8.4
8.4
10.4R2
8.4
8.4
8.4
72 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 7
Power System Components and
Descriptions
•
M320 Power System Description on page 73
•
M320 AC Power Supplies Description on page 73
•
M320 DC Power Supplies Description on page 74
•
M320 Power Supply LEDs on page 76
M320 Power System Description
The M320 router uses either AC power supplies (see
), isolated DC power supplies, or nonisolated DC power supplies
(see
“M320 DC Power Supplies Description” on page 74 ). The power supplies connect
to the midplane, which distributes the different output voltages produced by the power supplies to the router components, depending on their voltage requirements. All power supplies are hot-removable and hot-insertable. Each power supply is cooled by its own internal cooling system.
The M320 router is configurable with:
•
Two, three, or four AC power supplies
• Two or four DC power supplies (either isolated or nonisolated)
CAUTION: Mixing AC and DC power supplies is not supported and prevents the router from powering on. You must ensure that all power supplies are the same model number.
Related
Documentation
•
M320 Power Requirements on page 96
•
Troubleshooting the M320 Power System on page 292
M320 AC Power Supplies Description
In the AC power configuration, the router contains two to four load-sharing AC power supplies (see
Figure 22 on page 74 ), which are located at the lower rear of the chassis in
Copyright © 2015, Juniper Networks, Inc.
73
M320 Multiservice Edge Router Hardware Guide slots PEM0 through PEM3 (top to bottom). The router requires a minimum of two fully functional power supplies to operate.
To provide power redundancy, you can upgrade the number of AC power supplies from two to three or from three to four. Each AC power supply provides power to all components in the router.. Three AC power supplies provide full power redundancy. If one power supply fails or is removed, the remaining power supplies instantly assume the entire electrical load.
NOTE: In a router with two power supplies (no power supply redundancy), if one power supply fails or is shut down, the other power supply goes into a
“check” state and does not operate even though it has not failed (this is because the router requires two power supplies to operate).
Figure 22: AC Power Supply
Related
Documentation
•
M320 Power System Description on page 73
•
Connecting Power to an AC-Powered M320 Router on page 173
•
M320 AC Power Electrical Specifications on page 101
•
M320 AC Power Cord Specifications on page 102
M320 DC Power Supplies Description
In the DC power configuration, the router contains either two or four DC power supplies, located at the lower rear of the chassis in slots PEM0 through PEM3 (top to bottom).
If only two DC power supplies are installed, the power supplies in either slots PEM0 and
PEM1 or slots PEM2 and PEM3 can provide full power to the router. You can upgrade your
DC power supply from two to four power supplies for full redundancy.
74 Copyright © 2015, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions
NOTE: Except during upgrade, all DC power supplies installed in the chassis must be the same model number, either all isolated or all nonisolated DC power supplies. Using both isolated and nonisolated DC power supplies during normal operations prevents load sharing.
•
Nonisolated DC Power Supply on page 75
•
Isolated DC Power Supply on page 75
•
Components Powered by Each Power Supply Slot on page 75
•
DC Power Supply Load Sharing and Fault Tolerance on page 76
Nonisolated DC Power Supply
Each nonisolated power supply consists of a single DC input (-48 VDC and return), a circuit breaker, a fan (each power supply is cooled by its own internal cooling system), and LEDs to monitor the status of the power supply. Each nonisolated power supply weighs approximately 10 lb (4.5 kg).
Isolated DC Power Supply
Each isolated power supply consists of a single DC input (-48 VDC and return), a circuit breaker, a fan (each power supply is cooled by its own internal cooling system), and LEDs to monitor the status of the power supply. Each isolated power supply weighs approximately 10 lb (4.5 kg).
NOTE: The Isolated DC power supply is designed to be more resilient to power irregularity such as noise or surge in power environment.
Components Powered by Each Power Supply Slot
The DC power supplies in the slots indicated provide power to the components listed in
.
Table 50: Components Powered by Each DC Power Supply Slot
Slot Provide Power to These Components
PEM0 and PEM2
PEM1 and
PEM3
FPCs in slots FPC3 through FPC7
FPCs in slots
FPC0 through
FPC2
, SIBs, CBs, and Routing Engines, and fan trays.
Copyright © 2015, Juniper Networks, Inc.
75
M320 Multiservice Edge Router Hardware Guide
DC Power Supply Load Sharing and Fault Tolerance
When the router is fully configured with four DC power supplies:
•
The DC power supplies provide full redundancy
•
The DC power supply in PEM2 serves as the backup to the DC power supply in slot
PEM0
.
•
DC power supply in PEM3 serves as the backup to the DC power supply in slot PEM1
•
Load sharing occurs between the DC power supplies installed in slots PEM0 and PEM2
•
Load sharing occurs between the DC power supplies in slots PEM1 and PEM3
NOTE: Isolated DC power supplies share current over the full input operating voltage range. The current sharing between nonisolated power supplies relies on equal voltages at the power supply input terminals.
Related
Documentation
•
M320 Power System Description on page 73
•
Connecting Power to a DC-Powered M320 Router on page 174
•
Maintaining the M320 Power Supplies on page 278
•
Replacing an M320 DC Power Supply on page 250
•
•
M320 DC Power Electrical Specifications on page 105
M320 Power Supply LEDs
The OUTPUT OK LED on each power supply faceplate indicates the status of the power supply (see
, which applies to the AC and DC power supply). The power supply status is also reflected in two LEDs on the craft interface (see
Interface Power Supply LEDs” on page 19
). In addition, a power supply failure triggers the red alarm LED on the craft interface.
Table 51: Power Supply LED
Label Color State Description
OUTPUT OK
Blue Off No power applied to power supply.
Blinking •
•
•
•
Power supply blinks for 5 seconds after initial power on.
Power supply is installed, but not powered on, and is receiving bias power from a powered on power supply.
Input voltage is invalid.
Power supply has failed.
On steadily Power supply is functioning normally.
76 Copyright © 2015, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions
Related
Documentation
•
M320 Power System Description on page 73
•
Maintaining the M320 Power Supplies on page 278
•
Troubleshooting the M320 Power System on page 292
Copyright © 2015, Juniper Networks, Inc.
77
M320 Multiservice Edge Router Hardware Guide
78 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 8
Switch Fabric Components and
Descriptions
•
M320 SIB Description on page 79
•
M320 Performance for Different SIB Configurations on page 80
•
M320 SIB Description
The Switch Interface Boards (SIBs) provide the switching function to the destination
FPC. The SIBs (see
Figure 23 on page 79 ) create the switch fabric for the router, providing
up to a total of 385 million packets per second (Mpps) of forwarding with the maximum configuration.
SIBs are located at the center rear of the router chassis in the slots labeled SIB0 through
SIB3 (top to bottom). The M320 router can be configured with two, three, or four SIBs.
You can upgrade from two to three SIBs or from three to four SIBs without resetting or stopping Packet Forwarding Engines.
Each FPC has a dedicated ASIC with up to four high-speed links that connect to the SIBs
(one link per SIB).
SIBs are hot-insertable and hot-removable.
Figure 23: SIB-M
Each SIB consists of the following components:
Copyright © 2015, Juniper Networks, Inc.
79
M320 Multiservice Edge Router Hardware Guide
•
Switch Fabric ASICs.
• High-speed links (HSLs) to each FPC.
• Three LEDs located on the SIB faceplate that display the status of the SIB. See
.
•
SIB online/offline button, located on the SIB faceplate.
Related
Documentation
•
Replacing an M320 SIB on page 259
•
Maintaining the M320 SIBs on page 279
M320 Performance for Different SIB Configurations
describes expected performance per total active SIBs for different
FPC and PIC configurations. The packet forwarding rate of each FPC is independent of the number and configuration of other FPCs in the chassis. The packet forwarding rate depends on the total number of PICs in the FPC, the number of active SIBs in the chassis, and packet size.
Table 52: Performance per SIB/FPC Configuration
Number of Active
SIBs FPC Type and Number of PICs per FPC Performance
1 FPC1 with up to four PICs Line rate
FPC2 with up to two PICs (except when both PICs are 4-port GE PICs)
Line rate
2
FPC2 with two 4-port GE PICs
FPC2 with three or four PICs
FPC3 with one or two PICs
FPC1 with up to four PICs
Line rate not guaranteed
Line rate not guaranteed
Line rate not guaranteed
Line rate
FPC2 with up to four PICs (except when all PICS are 4-port GE PICs)
Line rate
FPC2 with four 4-port GE PICs
FPC2 with three 4-port GE PICs
FPC3 with two PICs
FPC3 with one PIC
Line rate not guaranteed
Line rate
Line rate not guaranteed
Line rate
80 Copyright © 2015, Juniper Networks, Inc.
Chapter 8: Switch Fabric Components and Descriptions
Table 52: Performance per SIB/FPC Configuration (continued)
Number of Active
SIBs FPC Type and Number of PICs per FPC Performance
3
4
FPC1 with up to four PICs
FPC2 with up to four PICs
FPC3 with two PICs
FPC1 with up to four PICs
FPC2 with up to four PICs
Line rate
Line rate
Line rate not guaranteed
Line rate
Line rate
FPC3 with up to two PICs Line rate
Related
Documentation
•
Replacing an M320 SIB on page 259
•
Maintaining the M320 SIBs on page 279
M320 SIB LEDs
describes the functions of the SIB LEDs. If all three LEDs are off, the
SIB is not receiving power. The OK and FAIL LEDs are replicated on the craft interface.
Table 53: SIB LEDs
Label Color State Description
Green On steadily SIB is in active mode.
ACTIVE
OK Green
FAIL
Yellow
On steadily SIB is functioning normally.
Blinking SIB is starting up.
On steadily SIB has failed.
Related
Documentation
•
M320 SIB Description on page 79
•
Replacing an M320 SIB on page 259
•
Maintaining the M320 SIBs on page 279
Copyright © 2015, Juniper Networks, Inc.
81
M320 Multiservice Edge Router Hardware Guide
82 Copyright © 2015, Juniper Networks, Inc.
PART 2
Site Planning, Preparation, and
Specifications
•
Preparation Overview on page 85
•
AC Power Specifications on page 101
•
DC Power Specifications on page 105
•
Network Cable and Transceiver Planning on page 111
•
Management Cable and Transceiver Specifications and Pinouts on page 115
Copyright © 2015, Juniper Networks, Inc.
83
M320 Multiservice Edge Router Hardware Guide
84 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 9
Preparation Overview
•
M320 Site Preparation Checklist Requirements on page 85
•
M320 Router Physical Specifications on page 86
•
Rack Requirements for the M320 Router on page 87
•
M320 Cabinet Size and Clearance Requirements on page 88
•
M320 Cabinet Airflow Requirements on page 90
•
M320 Clearance Requirements on page 91
•
M320 Environmental Specifications on page 93
•
M320 Chassis Grounding Cable and Lug Specifications on page 94
•
Site Electrical Wiring Guidelines for Juniper Networks Devices on page 95
•
M320 Power Requirements on page 96
•
M320 RJ-48 Connector Pinouts for the Control Board External Clock Inputs on page 98
•
M320 Fuse Specifications on page 99
M320 Site Preparation Checklist Requirements
The checklist in
summarizes the tasks you need to perform when preparing a site for router installation.
Table 54: Site Preparation Checklist
Item or Task For More Information Performed By Date
Environment
Verify that environmental factors such as temperature and humidity do not exceed router tolerances.
“M320 Environmental Specifications” on page 93
Power
Locate sites for connection of system grounding.
Calculate the power consumption and requirements.
“M320 Chassis Grounding Cable and
Lug Specifications” on page 94
“M320 Power Requirements” on page 96
Copyright © 2015, Juniper Networks, Inc.
85
M320 Multiservice Edge Router Hardware Guide
Table 54: Site Preparation Checklist (continued)
Item or Task For More Information
Hardware Configuration
Choose the configuration.
“M320 Chassis Description” on page 7
Rack
Verify that your rack meets the minimum requirements for the installation of the router.
“Rack Requirements for the M320
Plan rack location, including required space clearances.
“M320 Clearance Requirements” on page 91
If a rack is used, secure rack to floor and building structure.
“Rack Requirements for the M320
Cables
Acquire cables and connectors:
•
•
Determine the number of cables needed based on your planned configuration.
Review the maximum distance allowed for each cable. Choose the length of cable based on the distance between the hardware components being connected.
Power Margin for Fiber-Optic Cables” on page 112
Plan the cable routing and management.
“Maintaining M320 PICs and PIC
Performed By Date
Related
Documentation
•
M320 Installation Safety Guidelines on page 323
•
General Safety Guidelines for Juniper Networks Devices on page 315
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 335
M320 Router Physical Specifications
summarizes the physical specifications for the router chassis.
Table 55: M320 Physical Specifications
Description Value
Chassis dimensions 34.80 in. (88.4 cm) high
17.43 in. (44.3 cm) wide
25.64 in. (65.1 cm) deep (from front-mounting flange to chassis rear)
Total depth (including cable management system)
29.85 in. (75.8 cm)
86 Copyright © 2015, Juniper Networks, Inc.
Chapter 9: Preparation Overview
Table 55: M320 Physical Specifications (continued)
Description Value
Router weight Chassis with midplane: 142 lb (64.7 kg)
Maximum configuration: 439 lb (199.6 kg)
Rack Requirements for the M320 Router
The router can be installed in many types of racks, including four-post (telco) racks and open-frame racks. An example of an open-frame rack is shown in
.
For open-frame racks, center-mounting is preferable to front-mounting because the more even distribution of weight provides greater stability.
The router is designed for installation in a 19-in. rack as defined in Cabinets, Racks, Panels,
and Associated Equipment (document number EIA-310-D) published by the Electronics
Industry Association ( http://www.eia.org
).
With the use of adapters, the router can fit into a 600-mm-wide rack, as defined in the four-part Equipment Engineering (EE); European Telecommunications Standard for
Equipment Practice (document numbers ETS 300 119-1 through 119-4) published by the
European Telecommunications Standards Institute ( http://www.etsi.org
). Use approved wing devices to narrow the opening between the rails.
The rack rails must be spaced widely enough to accommodate the router chassis's external dimensions: 37.45 in. (95.1 cm) high, 31 in. (78.7 cm) deep, and 17.43 in. (44.3 cm) wide, excluding the front and rear cable management systems. The outer edges of the mounting brackets extend the width to 19 in. (48.3 cm). The spacing of rails and adjacent racks must also allow for the clearances around the router and rack.
The mounting holes for connecting the mounting brackets to the chassis are spaced
0.984 in. (25 mm) apart.
The chassis height of 37.45 in. (95.1 cm) is approximately 21.4 U. A U is the standard rack unit defined in Cabinets, Racks, Panels, and Associated Equipment (document number
EIA-310-D) published by the Electronics Industry Association. You can stack two routers in a rack that has at least 42.8 U (74.9 in. or 1.90 m) of usable vertical space.
The rack must be strong enough to support the weight of the fully configured router, up to 606 lb (275 kg). If you stack two fully configured routers in one rack, it must be capable of supporting about 1212 lb (550 kg).
Copyright © 2015, Juniper Networks, Inc.
87
M320 Multiservice Edge Router Hardware Guide
Figure 24: Typical Open-Frame Rack
Always secure the rack to the structure of the building. If your geographical area is subject to earthquakes, bolt the rack to the floor. For maximum stability, also secure the rack to ceiling brackets.
Related
Documentation
•
M320 Clearance Requirements on page 91
•
M320 Installation Safety Guidelines on page 323
M320 Cabinet Size and Clearance Requirements
The minimum size enclosed cabinet that can accommodate the router is 600 mm wide and 800 mm deep. A cabinet larger than the minimum requirement provides better airflow and reduces the chance of overheating. To accommodate a single router, the cabinet must be at least 20 U (35 in. or 88.9 cm) high. If you provide adequate cooling air and airflow clearance, you can stack two routers in a cabinet that has at least 40 U
(70 in. or 1.78 m) of usable vertical space.
The minimum front and rear clearance requirements depend on the mounting configuration you choose. The minimum total clearance inside the cabinet is 30.70 in.
between the inside of the front door and the inside of the rear door. If you choose a
88 Copyright © 2015, Juniper Networks, Inc.
Chapter 9: Preparation Overview
9
10
7
8
11
4
5
2
3
6 front-mount installation, you must maintain clearance of 4.80 in. (122 mm) between the front-mounting flanges and the inside of the cabinet front door, and 25.90 in. (658 mm) between the front-mounting flanges and the inside of the cabinet rear door. If you choose an adjustable-mount installation using the mounting brackets, the clearance requirements depend on where you install the mounting brackets.
provides the clearance requirements for each of the 11 mounting bracket positions on the side of the chassis (position 1 represents the mounting brackets installed closest to the front of the chassis; position 11 represents the mounting brackets installed closest to the rear of the chassis). The front clearance is measured between the front of the front rack rail and the inside of the cabinet front door. The rear clearance is measured between the front of the front rack rail and the inside of the cabinet rear door.
Table 56: Cabinet Clearance Requirements
Mounting
Bracket
Position Front Clearance Rear Clearance
1 7.04 in. (179 mm) 23.66 in. (601 mm)
8.02 in. (204 mm)
9.01 in. (229 mm)
9.99 in. (254 mm)
10.98 in. (279 mm)
11.96 in. (304 mm)
12.94 in. (329 mm)
13.93 in. (354 mm)
14.91 in. (379 mm)
15.90 in. (404 mm)
16.88 in. (429 mm)
22.68 in. (576 mm)
21.69 in. (551 mm)
20.71 in. (526 mm)
19.73 in. (501 mm)
18.74 in. (476 mm)
17.76 in. (451 mm)
16.77 in. (426 mm)
15.79 in. (401 mm)
14.81 in. (376 mm)
13.82 in. (351 mm)
Related
Documentation
•
M320 Site Preparation Checklist Requirements on page 85
•
M320 Installation Safety Guidelines on page 323
Copyright © 2015, Juniper Networks, Inc.
89
M320 Multiservice Edge Router Hardware Guide
M320 Cabinet Airflow Requirements
When you mount the router in a cabinet, you must ensure that ventilation through the cabinet is sufficient to prevent overheating. Following is a list of requirements to consider when planning for chassis cooling:
•
Ensure that the cool air supply you provide through the cabinet can adequately dissipate
the thermal output of the router.
“M320 Environmental Specifications” on page 93
lists the router's environmental specifications, including its operating temperature and thermal output.
•
Ensure that the cabinet allows the chassis hot exhaust air to exit from the cabinet without recirculating into the router. An open cabinet (without a top or doors) that employs hot air exhaust extraction from the top allows the best airflow through the chassis. If the cabinet contains a top or doors, perforations in these elements assist with removing the hot air exhaust. For an illustration of chassis airflow, see
Cooling System Description” on page 21 .
• Install the router as close as possible to the front of the cabinet so that the cable management system just clears the inside of the front door. This maximizes the clearance in the rear of the cabinet for critical airflow.
• If you operate the router in an enclosed 800-mm cabinet, you must install a baffle on the inside of the rear door of the cabinet to prevent the router from overheating at elevated ambient temperatures. The baffle separates the cool air intake from the hot air exhaust in the rear of the cabinet (for baffle dimensions and location, see
). We recommend that the baffle be made of soft foam with a depth of 2.25 in. (57 mm) so that it slightly touches the rear of the router when the rear cabinet door is closed.
•
Route and dress all cables to minimize the blockage of airflow to and from the chassis.
90 Copyright © 2015, Juniper Networks, Inc.
Figure 25: Airflow Baffle Template
Chapter 9: Preparation Overview
Related
Documentation
•
Maintaining the M320 Air Filters on page 267
•
Maintaining the M320 Fan Trays on page 268
•
Troubleshooting the M320 Cooling System on page 287
M320 Clearance Requirements
When planning the installation site, you need to allow sufficient clearance around the rack (see
):
• For the cooling system to function properly, the airflow around the chassis must be unrestricted.
“M320 Cooling System Description” on page 21
depicts the airflow in the router.
• For service personnel to remove and install hardware components, there must be adequate space at the front and back of the router. We recommend that you allow at least 30 in. (72.6 cm) in front of the rack and 24 in. (61.0 cm) behind the rack.
Copyright © 2015, Juniper Networks, Inc.
91
M320 Multiservice Edge Router Hardware Guide
Figure 26: Chassis Dimensions and Clearance Requirements
The router has two adjustable center-mounting brackets that are initially attached to the mounting holes closest to the rear of the chassis. You can move the pair of adjustable center-mounting brackets to one of 11 positions on the side of the chassis. The mounting holes for connecting the mounting brackets to the chassis are spaced 0.984 in. (25 mm) apart.
For instructions about installing the mounting hardware, see
Hardware for a Four-Post Rack or Cabinet” on page 127
.
The chassis height of 34.80 in. (88.4 cm) is approximately 20 U. A U is the standard rack unit defined in Cabinets, Racks, Panels, and Associated Equipment (document number
EIA-310-D) published by the Electronics Industry Association. You can stack two M320 routers in a rack that has at least 40 U (70 in. or 1.78 m) of usable vertical space.
The rack must be strong enough to support the weight of the fully configured router, up to 439 lb (199.6 kg). If you stack two fully configured routers in one rack, it must be capable of supporting about 878 lb (399.1 kg).
92 Copyright © 2015, Juniper Networks, Inc.
Figure 27: Typical Open-Frame Rack
Chapter 9: Preparation Overview
Related
Documentation
•
M320 Site Preparation Checklist Requirements on page 85
•
M320 Installation Safety Guidelines on page 323
M320 Environmental Specifications
specifies the environmental specifications required for normal router operation. In addition, the site should be as dust-free as possible.
Table 57: Router Environmental Specifications
Description Value
Altitude
Relative humidity
No performance degradation to 10,000 ft (3048 m)
Normal operation ensured in relative humidity range of 5% to 90%, noncondensing
Copyright © 2015, Juniper Networks, Inc.
93
M320 Multiservice Edge Router Hardware Guide
Table 57: Router Environmental Specifications (continued)
Description Value
Temperature Normal operation ensured in temperature range of 32°F (0°C) to
104°F (40°C)
Nonoperating storage temperature in shipping crate: –40°F (–40°C) to 158°F (70°C)
Seismic Designed to meet Telcordia Technologies Zone 4 earthquake requirements
Maximum thermal output DC power: 28,498 BTU/hour (8350 W)
NOTE: Install the router only in restricted areas, such as dedicated equipment rooms and equipment closets, in accordance with Articles 110-16, 110-17, and
110-18 of the National Electrical Code, ANSI/NFPA 70.
Related
Documentation
•
M320 Site Preparation Checklist Requirements on page 85
•
Routine Maintenance Procedures for the M320 Router on page 265
•
General Electrical Safety Warnings for Juniper Networks Devices on page 341
M320 Chassis Grounding Cable and Lug Specifications
The grounding cable must meet the following requirements:
•
Ability to handle up to 82 A
•
6-AWG (13.3 mm
2
), minimum 75°C wire, or as permitted by the local code
The cable lug shown in
is also used for the DC power cables.
Figure 28: DC Power and Grounding Cable Lug
2.25
End view
0.55
0.28
diameter each hole
Crimp area
6 AWG conductor
0.08
0.25
0.625
0.37
All measurements in inches
NOTE: Additional grounding is provided to an AC-powered router when you plug its power supplies into grounded AC power receptacles.
94 Copyright © 2015, Juniper Networks, Inc.
Chapter 9: Preparation Overview
Related
Documentation
•
M320 Site Preparation Checklist Requirements on page 85
•
M320 Power System Description on page 73
•
Connecting the M320 Router Grounding Cable on page 161
Site Electrical Wiring Guidelines for Juniper Networks Devices
•
Distance Limitations for Signaling on page 95
•
Radio Frequency Interference on page 95
•
Electromagnetic Compatibility on page 95
Distance Limitations for Signaling
Improperly installed wires can emit radio interference. In addition, the potential for damage from lightning strikes increases if wires exceed recommended distances or if wires pass between buildings. The electromagnetic pulse (EMP) caused by lightning can damage unshielded conductors and destroy electronic devices. If your site has previously experienced such problems, you might want to consult experts in electrical surge suppression and shielding.
Radio Frequency Interference
You can reduce or eliminate the emission of radio frequency interference (RFI) from your site wiring by using twisted-pair cable with a good distribution of grounding conductors.
If you must exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal when applicable.
Electromagnetic Compatibility
If your site is susceptible to problems with electromagnetic compatibility (EMC), particularly from lightning or radio transmitters, you might want to seek expert advice.
Strong sources of electromagnetic interference (EMI) can destroy the signal drivers and receivers in the network device and conduct power surges over the lines into the equipment, resulting in an electrical hazard. It is particularly important to provide a properly grounded and shielded environment and to use electrical surge-suppression devices.
CAUTION: To comply with intrabuilding lightning and surge requirements, intrabuilding wiring must be shielded, and the shield for the wiring must be grounded at both ends.
WARNING: The intrabuilding port(s) of the equipment or subassembly is suitable for connection to intrabuilding or unexposed wiring or cabling only.
The intrabuilding port(s) of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or its wiring.
These interfaces are designed for use as intrabuilding interfaces only (Type
2 or Type 4 ports as described in GR-1089-CORE, Issue 4) and require isolation
Copyright © 2015, Juniper Networks, Inc.
95
M320 Multiservice Edge Router Hardware Guide from the exposed OSP cabling. The addition of primary protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.
Related
Documentation
•
General Electrical Safety Guidelines and Electrical Codes for Juniper Networks Devices on page 345
M320 Power Requirements
NOTE: To allow for future growth so that you can operate the router in any hardware configuration without upgrading the power infrastructure, we recommend that you provision at least 48 A @ –48 VDC (nominal) for each
DC power supply. If you do not plan to provision at least 48 A @ –48 VDC
(nominal) per input, you can use the information in
to calculate the typical power consumption @ –48 VDC and typical thermal output for your hardware configuration.
lists the power requirements for various hardware components when the router is operating under typical voltage conditions. Generalized values are listed for PICs. For power requirements for specific PICs, see the M320 Multiservice Edge
Router Interface Module Reference.
Table 58: Component Power Requirements
Component
Power
Requirement
(Watts)
Current
Requirement
(Amps @
–48 VDC)
Base system, not including FPCs and PICs (includes four
SIBs, one host subsystem, two power supplies, cooling system running at normal speed, and craft interface)
450 W
(approximate)
Type 1 FPC (without PICs) 160 W
9.4 A
(approximate)
3.3 A
Type 2 FPC (without PICs)
Type 3 FPC (without PICs)
Host subsystem (Routing Engine and CB)
SIB
AC power supply
DC power supply
160 W
160 W
100 W
38 W
100 W
40 W
3.3 A
3.3 A
2.1 A
0.8 A
Not applicable.
0.8 A
96 Copyright © 2015, Juniper Networks, Inc.
Chapter 9: Preparation Overview
Table 58: Component Power Requirements (continued)
Component
Cooling system (normal speed)
Cooling system (full speed)
PIC—Generalized typical value
PIC—Generalized maximum value
Power
Requirement
(Watts)
140 W
200 W
30 W
52.8 W
Current
Requirement
(Amps @
–48 VDC)
2.9 A
4.0 A
0.625 A
1.1 A
You can use the information in
and the M320 Multiservice Edge
Router Interface Module Reference to calculate power consumption for various hardware configurations, input current from a different source voltage, and thermal output, as shown in the following examples for a DC-powered router.
•
Example of calculating power consumption for minimum configuration:
Base system + 1 FPC + 1 PIC =
9.4 A + 3.3 A + 0.625 A = 13.3 A @ –48 VDC = 638 W DC
• Example of calculating power consumption for maximum configuration:
Base system + 1 Host subsystem + 2 redundant DC power supplies + 8 FPCs + 32 PICs
=
9.4 A + 2.1 A + 2(0.8) A + 8(3.3 A) + 32(1.1 A) =
9.4 A + 2.1 A + 1.6 A + 26.4 A + 35.2 A = 74.7 A @ –48 VDC =3,586 W DC
• Current requirement adjustment for fans running at full speed (high temperature environment or cooling component failure):
Calculated system current (X) – Cooling (normal) + Cooling (full speed) =
X A – 2.9 A + 4.0 A =
X A + 1.1 A
• Input current from a DC source other than –48 VDC (based on maximum configuration; applies to DC power supply only):
(–54 VDC input) x (input current X) = (–48 VDC input) x (input current Y)
54 x X = 48 x 57.9 A
X = 48 x 57.9 A/54 = 51.5 A
• Example of calculating system thermal output for a DC-powered router:
•
Watts DC/0.293 = BTU/hr
3,586/0.293 = 12,239 BTU/hr
Example of calculating system thermal output for an AC-powered router:
Watts DC/85% AC PEM efficiency/0.293 = BTU/hr
3,586/0.85/0.293 = 14,398 BTU/hr
Related
Documentation
•
M320 Power System Description on page 73
Copyright © 2015, Juniper Networks, Inc.
97
M320 Multiservice Edge Router Hardware Guide
•
M320 AC Power Supplies Description on page 73
•
M320 DC Power Supplies Description on page 74
•
M320 AC Power Electrical Specifications on page 101
•
M320 DC Power Electrical Specifications on page 105
M320 RJ-48 Connector Pinouts for the Control Board External Clock Inputs
1
2
3
The two inputs on the CB labeled EXTERNAL CLOCK INPUT are RJ-48 receptacles that accept RJ-48 cables for connecting the CB to 19.44-MHz Stratum 3 reference clocks. .
describes the RJ-48 connector pinouts.
Table 59: RJ-48 Connector Pinouts
Pin Signal
EXT_RRING (negative input clock)
EXT_RTIP (positive input clock)
Shield ground
6
7
4
5
8
EXT_TRING (negative output signal—not a clock)
EXT_TTIP (positive output signal—not a clock)
Shield ground
Not used
Not used
Connecting an External Clock Device to the M320 Control Board
1.
Related
Documentation
•
M320 Control Board (CB) Description on page 45
•
M320 Chassis Description on page 7
•
M320 Craft Interface Description on page 15
98 Copyright © 2015, Juniper Networks, Inc.
Chapter 9: Preparation Overview
M320 Fuse Specifications
Table 60: Fuse Specifications
Component
Indicator Bulb
Color Fuse Rating
CB
FPC
SIB
Spares
Spares
Red and blue
Red and blue
Red and blue
Red and blue
Red and blue
15 A
15 A
15 A
15 A
15 A
Quantity
2
8
4
4
6
Locations
J411 C
J416 A
J410 A and D
J412 A and D
J414 D
J415 A and D
J416 C
J412 B and C
J415 B
J416 D
J410 B and C
J414 C
J415 C
J411 A, B, and D
J414 A and B
J416 B
Related
Documentation
•
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
Troubleshooting the M320 Fuses on page 290
Copyright © 2015, Juniper Networks, Inc.
99
M320 Multiservice Edge Router Hardware Guide
100 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 10
AC Power Specifications
•
M320 AC Power Electrical Specifications on page 101
•
M320 AC Power Cord Specifications on page 102
M320 AC Power Electrical Specifications
lists the AC power supply and power system electrical specifications.
For information about AC power cord specifications, see
Specifications” on page 102 . For information about connecting the router to power, see
“Connecting Power to an AC-Powered M320 Router” on page 173
.
Table 61: AC Power Electrical Specifications
Item Specification
Power Supply
Maximum output power
AC input voltage
AC input line frequency
AC input current rating
1750 W
Operating range: 180 to 264 VAC
47 to 63 Hz
10 A @ 200 VAC
8.5 A @ 240 VAC
Power System
AC input voltage
AC input line frequency
AC system current rating
Operating range: 200 to 240 VAC
47 to 63 Hz
17 A @ 200 VAC
14 A @ 240 VAC
Copyright © 2015, Juniper Networks, Inc.
101
M320 Multiservice Edge Router Hardware Guide
NOTE: If you plan to operate a maximally configured AC-powered router, we recommend that you provision at least 14 A @ 240 VAC (or 17 A @ 200 VAC) for the system, or at least 10 A for each power supply.
Each AC power supply has a single AC appliance inlet that requires a dedicated AC power feed and a dedicated 15 A (250 VAC) circuit breaker. Use a facility circuit breaker rated for 15 A (250 VAC) minimum for each AC power supply. Doing so enables you to operate the router in any configuration without upgrading the power infrastructure.
Related
Documentation
•
M320 AC Power Supplies Description on page 73
•
Replacing an M320 AC Power Supply Cord on page 254
M320 AC Power Cord Specifications
Most sites distribute power through a main conduit that leads to frame-mounted power distribution panels, one of which can be located at the top of the rack that houses the router. An AC power cord connects each power supply to the power distribution panel.
Detachable AC power cords, each 2.5 m (approximately 8 ft) long, are supplied with the router. The appliance coupler at the female end of the cord inserts into the appliance inlet on the faceplate of the AC power supply. The coupler is type C19 and C19W (right angle) as described by International Electrotechnical Commission (IEC) standard 60320.
The plug at the male end of the power cord fits into the power source receptacle that is standard for your geographical location.
WARNING: The AC power cord for the router is intended for use with the router only and not for any other use.
WARNING: Translation from Japanese: The attached power cable is only for this product. Do not use the cable for another product.
102 Copyright © 2015, Juniper Networks, Inc.
Chapter 10: AC Power Specifications
NOTE: In North America, AC power cords must not exceed 4.5 m
(approximately 14.75 ft) in length, to comply with National Electrical Code
(NEC) Sections 400-8 (NFPA 75, 5-2.2) and 210-52, and Canadian Electrical
Code (CEC) Section 4-010(3). The cords supplied with the router are in compliance.
provides AC power cord specifications and
depicts the plug on the AC power cord provided for each country or region.
Table 62: AC Power Cord Specifications
Country Model Number Electrical Specification Plug Type
Australia CBL-M-PWR-RA-AU 240 VAC, 50 Hz AC SAA/3
220 VAC, 50 Hz AC PSB-10
220 or 230 VAC, 50 Hz AC CEE 7/7
China CBL-M-PWR-RA-CH
Europe (except Denmark,
Italy, Switzerland, and
United Kingdom)
CBL-M-PWR-RA-EU
Italy
Japan
North America
CBL-M-PWR-RA-IT
CBL-M-PWR-RA-JP
CBL-M-PWR-RA-US
United Kingdom
CBL-M-PWR-RA-TWLK-US
CBL-M-PWR-RA-UK
230 VAC, 50 Hz AC
220 VAC, 50 or 60 Hz AC
250 VAC, 60 Hz AC
250 VAC, 60 Hz AC
240 VAC, 50 Hz AC
CEI 23-16/VII
NEMA L6-20P
NEMA L6-20
NEMA L6-20P
BS89/13
Figure 29: AC Plug Types
Australia
(SAA/3)
China
(PSB-10)
Europe
(CEE 7/7)
Italy
(CEI 23-16/VII)
Japan
(L6-20P)
North America
(L6-20P)
North America
NEMA
(L6-20)
UK
(BS89/13)
Copyright © 2015, Juniper Networks, Inc.
103
M320 Multiservice Edge Router Hardware Guide
CAUTION: AC Power cords must not block access to router components or drape where people could trip on them.
Related
Documentation
•
M320 AC Power Supplies Description on page 73
•
M320 Power Requirements on page 96
•
M320 AC Power Electrical Specifications on page 101
•
Connecting Power to an AC-Powered M320 Router on page 173
•
Replacing an M320 AC Power Supply Cord on page 254
•
Site Electrical Wiring Guidelines for Juniper Networks Devices on page 95
104 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 11
DC Power Specifications
•
M320 DC Power Electrical Specifications on page 105
•
M320 DC Power Cable Specifications on page 107
•
M320 DC Power Distribution on page 109
•
DC Power Circuit Breaker for M320 Routers on page 109
M320 DC Power Electrical Specifications
•
DC Power System Electrical Specifications on page 105
•
Nonisolated DC Power Supply Electrical Specifications on page 106
•
Isolated DC Power Supply Electrical Specifications on page 106
DC Power System Electrical Specifications
lists the DC power system electrical specifications.
Table 63: DC Power System Electrical Specifications
Item Specification
DC input voltage
DC system current rating
Operating range: –40.0 to –72.0 VDC
NOTE: If the input voltage from the DC power source drops between
–37.5 and –39.5 VDC, the router automatically shuts down. During automatic shutdown, the circuit remains active. When the input voltage returns to –43 to –44 VDC, the router automatically starts up again and the system returns to normal operation within 30 minutes. No operator intervention is required.
65 A @ –48 VDC (nominal) (3120 W)
Copyright © 2015, Juniper Networks, Inc.
105
M320 Multiservice Edge Router Hardware Guide
NOTE: To allow for future growth so that you can operate the router in any hardware configuration without upgrading the power infrastructure, we recommend that you provision at least 48 A @ –48 VDC (nominal) for each power supply. To base the amount of power you provision on the typical power consumption @ –48 VDC (nominal) for your current hardware configuration, you can use the information in
“M320 Power Requirements” on page 96
.
Nonisolated DC Power Supply Electrical Specifications
list the electrical specifications for nonisolated DC power supplies.
Table 64: Nonisolated DC Power Supply Electrical Specifications
Item Specification
Maximum output power
DC input voltage
2000 W
Nominal: –48 VDC, –60 VDC
Operating range: –40.5 to –72 VDC
NOTE: If the input voltage from the DC power source drops below
–40.5 VDC, the router automatically shuts down. During automatic shutdown, the circuit remains active. When the input voltage returns to –42.75 VDC, the router automatically starts up again and the system returns to normal operation within 30 minutes. No operator intervention is required.
DC input current rating
Internal Supplementary
Protector
42 A @ –48 VDC
50 A
Isolated DC Power Supply Electrical Specifications
list the electrical specifications for isolated DC power supplies.
Table 65: Isolated DC Power Supply Electrical Specifications
Item Specification
Maximum output power 2000 W
106 Copyright © 2015, Juniper Networks, Inc.
Chapter 11: DC Power Specifications
Table 65: Isolated DC Power Supply Electrical Specifications (continued)
Item Specification
DC input voltage
DC input current rating
Internal Supplementary
Protector
Nominal: –48 VDC, –60 VDC
Operating range: –40.0 to –72.0 VDC
NOTE: If the input voltage from the DC power source drops between
–37.5 and –39.5 VDC, the router automatically shuts down. During automatic shutdown, the circuit remains active. When the input voltage returns to –43 to –44 VDC, the router automatically starts up again and the system returns to normal operation within 30 minutes. No operator intervention is required.
48 A @ –48 VDC
60 A
Related
Documentation
•
M320 DC Power Supplies Description on page 74
•
Connecting Power to a DC-Powered M320 Router on page 174
M320 DC Power Cable Specifications
The accessory box shipped with the router includes the cable lugs that attach to the terminal studs of each power supply (see
Figure 30 on page 107 ). (The cable lug shown
in is also used for the grounding the chassis.)
Figure 30: DC Power Cable Lug
2.25
End view
0.55
0.28
diameter each hole
6 AWG conductor
Crimp area
0.08
0.25
0.625
0.37
All measurements in inches
CAUTION: Before router installation begins, a licensed electrician must attach a cable lug to the grounding and power cables that you supply. A cable with an incorrectly attached lug can damage the router.
summarizes the specifications for the power cables, which you must supply.
Copyright © 2015, Juniper Networks, Inc.
107
M320 Multiservice Edge Router Hardware Guide
Table 66: DC Power Cable Specifications
Cable Type Quantity and Specification
Power Eight 4-AWG (21.2 mm
2
) (minimum) copper conductor, or as permitted by the local code.
Connector Specification
Cable lug; dual hole, sized to fit
1/4-20 UNC terminal studs at
15.86-mm (0.625-in.) center line.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
shows a typical DC source cabling arrangement.
Figure 31: Typical DC Source Cabling to the Router
108
WARNING: For field-wiring connections, use copper conductors only.
For other electrical safety information, see M320 General Electrical Safety
Guidelines and Electrical Codes,
“M320 DC Power Electrical Safety Guidelines” on page 346 , and
“DC Power Electrical Safety Warnings for Juniper Networks
.
CAUTION: Power cords and cables must not block access to router components or drape where people could trip on them.
For a description of the DC power supply, see , as opposed to the DC power configuration
(see
“M320 DC Power Supplies Description” on page 74
for more information). For instructions on connecting the DC power and grounding cables during initial installation,
Copyright © 2015, Juniper Networks, Inc.
Chapter 11: DC Power Specifications see
“Connecting Power to a DC-Powered M320 Router” on page 174
. For instructions on replacing a DC power cable, see
“Replacing an M320 DC Power Supply Cable” on page 255 .
Related
Documentation
•
M320 Power System Description on page 73
•
M320 Power Supply LEDs on page 76
•
M320 Power Requirements on page 96
M320 DC Power Distribution
Most sites distribute DC power through a main conduit that leads to frame-mounted DC power distribution panels, one of which might be located at the top of the rack that houses the router. A pair of cables (one input and one return) connects each set of terminal studs to the power distribution panel.
NOTE: The DC power supplies in slots PEM0 and PEM1 must be powered by dedicated power feeds derived from feed A, and the DC power supplies in slots PEM2 and PEM3 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
Related
Documentation
•
M320 DC Power Cable Specifications on page 107
DC Power Circuit Breaker for M320 Routers
Each DC power supply has a single DC input (–48 VDC and return). To enable you to operate the router in any configuration without upgrading the power infrastructure, we recommend that you use a dedicated customer site circuit breaker rated for
60 A (–48 VDC) minimum for each power supply. If you do not provision a 60 A (–48 VDC) circuit breaker, provision a customer site circuit breaker for each DC power supply rated for at least 125% of the continuous current that the system draws at –48 VDC, or as required by local code.
Related
Documentation
•
M320 DC Power Cable Specifications on page 107
•
M320 DC Power Distribution on page 109
•
M320 Power Requirements on page 96
Copyright © 2015, Juniper Networks, Inc.
109
M320 Multiservice Edge Router Hardware Guide
110 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 12
Network Cable and Transceiver Planning
•
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 111
•
Calculating Power Budget and Power Margin for Fiber-Optic Cables on page 112
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion
This topic describes signal loss, attenuation, and dispersion in fiber-optic cable. For information about calculating power budget and power margin for fiber-optic cable, see
“Calculating Power Budget and Power Margin for Fiber-Optic Cables” on page 112
and
Supported Network Interface Standards by Transceiver for ACX, M, MX, and T Series Routers
or Supported Network Interface Standards by Transceiver for PTX Series Routers.
•
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable on page 111
•
Attenuation and Dispersion in Fiber-Optic Cable on page 111
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable
Multimode fiber is large enough in diameter to allow rays of light to reflect internally
(bounce off the walls of the fiber). Interfaces with multimode optics typically use LEDs as light sources. However, LEDs are not coherent sources. They spray varying wavelengths of light into the multimode fiber, which reflects the light at different angles. Light rays travel in jagged lines through a multimode fiber, causing signal dispersion. When light traveling in the fiber core radiates into the fiber cladding, higher-order mode loss (HOL) results. Together these factors limit the transmission distance of multimode fiber compared with single-mode fiber.
Single-mode fiber is so small in diameter that rays of light can reflect internally through one layer only. Interfaces with single-mode optics use lasers as light sources. Lasers generate a single wavelength of light, which travels in a straight line through the single-mode fiber. Compared with multimode fiber, single-mode fiber has higher bandwidth and can carry signals for longer distances.
Exceeding the maximum transmission distances can result in significant signal loss, which causes unreliable transmission.
Attenuation and Dispersion in Fiber-Optic Cable
Correct functioning of an optical data link depends on modulated light reaching the receiver with enough power to be demodulated correctly. Attenuation is the reduction in
Copyright © 2015, Juniper Networks, Inc.
111
M320 Multiservice Edge Router Hardware Guide power of the light signal as it is transmitted. Attenuation is caused by passive media components, such as cables, cable splices, and connectors. Although attenuation is significantly lower for optical fiber than for other media, it still occurs in both multimode and single-mode transmission. An efficient optical data link must have enough light available to overcome attenuation.
Dispersion is the spreading of the signal in time. The following two types of dispersion can affect an optical data link:
•
Chromatic dispersion—Spreading of the signal in time resulting from the different speeds of light rays.
• Modal dispersion—Spreading of the signal in time resulting from the different propagation modes in the fiber.
For multimode transmission, modal dispersion, rather than chromatic dispersion or attenuation, usually limits the maximum bit rate and link length. For single-mode transmission, modal dispersion is not a factor. However, at higher bit rates and over longer distances, chromatic dispersion rather than modal dispersion limits maximum link length.
An efficient optical data link must have enough light to exceed the minimum power that the receiver requires to operate within its specifications. In addition, the total dispersion must be less than the limits specified for the type of link in Telcordia Technologies document GR-253-CORE (Section 4.3) and International Telecommunications Union
(ITU) document G.957.
When chromatic dispersion is at the maximum allowed, its effect can be considered as a power penalty in the power budget. The optical power budget must allow for the sum of component attenuation, power penalties (including those from dispersion), and a safety margin for unexpected losses.
Related
Documentation
Calculating Power Budget and Power Margin for Fiber-Optic Cables
Use the information in this topic and the information in Supported Network Interface
Standards by Transceiver for ACX, M, MX, and T Series Routers or Supported Network
Interface Standards by Transceiver for PTX Series Routers to calculate the power budget and power margin for fiber-optic cables.
To calculate the power budget and power margin, perform the following tasks:
1.
Calculating Power Budget for Fiber-Optic Cable on page 112
2.
Calculating Power Margin for Fiber-Optic Cable on page 113
Calculating Power Budget for Fiber-Optic Cable
To ensure that fiber-optic connections have sufficient power for correct operation, you need to calculate the link's power budget, which is the maximum amount of power it can transmit. When you calculate the power budget, you use a worst-case analysis to provide a margin of error, even though all the parts of an actual system do not operate
112 Copyright © 2015, Juniper Networks, Inc.
Chapter 12: Network Cable and Transceiver Planning at the worst-case levels. To calculate the worst-case estimate of power budget (P
B you assume minimum transmitter power (P
T
) and minimum receiver sensitivity (P
R
),
):
P
B
= P
T
– P
R
The following hypothetical power budget equation uses values measured in decibels
(dB) and decibels referred to one milliwatt (dBm):
P
B
= P
T
– P
R
P
B
= –15 dBm – (–28 dBm)
P
B
= 13 dB
Calculating Power Margin for Fiber-Optic Cable
After calculating a link's power budget, you can calculate the power margin (P
M
), which represents the amount of power available after subtracting attenuation or link loss (LL) from the power budget (P
B
). A worst-case estimate of P
M assumes maximum LL:
P
M
= P
B
– LL
A P
M greater than zero indicates that the power budget is sufficient to operate the receiver.
Factors that can cause link loss include higher-order mode losses (HOL), modal and chromatic dispersion, connectors, splices, and fiber attenuation.
lists an estimated amount of loss for the factors used in the following sample calculations.
For information about the actual amount of signal loss caused by equipment and other factors, refer to vendor documentation.
Table 67: Estimated Values for Factors Causing Link Loss
Link-Loss Factor Estimated Link-Loss Value
Higher-order mode losses
Modal and chromatic dispersion
Connector
Splice
Fiber attenuation
Single-mode—None
Multimode—0.5 dB
Single-mode—None
Multimode—None, if product of bandwidth and distance is less than 500 MHz-km
0.5 dB
0.5 dB
Single-mode—0.5 dB/km
Multimode—1 dB/km
Copyright © 2015, Juniper Networks, Inc.
113
M320 Multiservice Edge Router Hardware Guide
The following example uses the estimated values in
to calculate link loss (LL) for a 2-km-long multimode link with a power budget (P
B
) of 13 dB:
•
Fiber attenuation for 2 km @ 1.0 dB/km = 2 dB
•
Loss for five connectors @ 0.5 dB per connector = 5(0.5 dB) = 2.5 dB
• Loss for two splices @ 0.5 dB per splice = 2(0.5 dB) = 1 dB
• Higher-order mode loss = 0.5 dB
•
Clock recovery module = 1 dB
The power margin (P
M
) is calculated as follows:
P
M
= P
B
– LL
P
M
= 13 dB – 2 km (1.0 dB/km) – 5 (0.5 dB) – 2 (0.5 dB) – 0.5 dB [HOL] – 1 dB [CRM]
P
M
= 13 dB – 2 dB – 2.5 dB – 1 dB – 0.5 dB – 1 dB
P
M
= 6 dB
The following sample calculation for an 8-km-long single-mode link with a power budget
(P
B
) of 13 dB uses the estimated values from
to calculate link loss
(LL) as the sum of fiber attenuation (8 km @ 0.5 dB/km, or 4 dB) and loss for seven connectors (0.5 dB per connector, or 3.5 dB). The power margin (P
M follows:
) is calculated as
P
M
= P
B
– LL
P
M
= 13 dB – 8 km (0.5 dB/km) – 7(0.5 dB)
P
M
= 13 dB – 4 dB – 3.5 dB
P
M
= 5.5 dB
In both examples, the calculated power margin is greater than zero, indicating that the link has sufficient power for transmission and does not exceed the maximum receiver input power.
Related
Documentation
•
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 111
114 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 13
Management Cable and Transceiver
Specifications and Pinouts
•
M320 Routing Engine Interface Cable and Wire Specifications on page 115
•
M320 RJ-45 Connector Pinouts for the Routing Engine ETHERNET Port on page 116
•
M320 DB-9 Connector Pinouts for the Routing Engine AUX and CONSOLE
M320 Routing Engine Interface Cable and Wire Specifications
lists the specifications for the cables that connect to management ports and the wires that connect to the alarm relay contacts.
Table 68: Cable and Wire Specifications for Routing Engine Management and Alarm Interfaces
Port Cable Specification
Cable/Wire
Supplied
Maximum
Length
Router
Receptacle
DB-9 male Routing Engine console or auxiliary interface
Routing Engine
Ethernet interface
Alarm relay contacts
RS-232 (EIA-232) serial cable
One 6-ft (1.83-m) length with
DB-9/DB-9 connectors
6 ft
(1.83 m)
Category 5 cable or equivalent suitable for
100Base-T operation
One 15-ft (4.57-m) length with
RJ-45/RJ-45 connectors
328 ft
(100 m)
Wire with gauge between 28-AWG and
14-AWG (0.08 and 2.08
mm
2
)
NO None
RJ-45 autosensing
—
Related
Documentation
•
M320 Routing Engine Description on page 24
•
M320 Connector Interface Panel (CIP) Description on page 13
•
M320 Site Preparation Checklist Requirements on page 85
Copyright © 2015, Juniper Networks, Inc.
115
M320 Multiservice Edge Router Hardware Guide
M320 RJ-45 Connector Pinouts for the Routing Engine ETHERNET Port
3
4
1
2
5
The port on the CIP labeled ETHERNET is an autosensing 10/100 millions of packets per second (Mbps) Ethernet RJ-45 receptacle that accepts an Ethernet cable for connecting the Routing Engine to a management LAN (or other device that supports out-of-band management).
describes the RJ-45 connector pinouts.
Table 69: RJ-45 Connector Pinouts
Pin Signal
TX+
TX –
RX+
Termination network
Termination network
6
7
8
RX–
Termination network
Termination network
Related
Documentation
•
M320 Chassis Description on page 7
•
M320 Connector Interface Panel (CIP) Description on page 13
•
M320 Site Preparation Checklist Requirements on page 85
M320 DB-9 Connector Pinouts for the Routing Engine AUX and CONSOLE Ports
1
2
3
The ports on the CIP labeled AUXILIARY and CONSOLE are DB-9 receptacles that accept
RS-232 (EIA-232) cable. The AUXILIARY port connects the Routing Engine to a laptop, modem, or other auxiliary unit, and the CONSOLE port connects it to a management
console. The ports are configured as data terminal equipment (DTE).
describes the DB-9 connector pinouts.
Table 70: DB-9 Connector Pinouts
Pin Signal Direction Description
DCD
RxD
TxD
<–
<–
–>
Carrier Detect
Receive Data
Transmit Data
116 Copyright © 2015, Juniper Networks, Inc.
Chapter 13: Management Cable and Transceiver Specifications and Pinouts
6
7
4
5
Table 70: DB-9 Connector Pinouts (continued)
Pin Signal Direction Description
DTR
Ground
DSR
RTS
–>
—
<–
–>
Data Terminal Ready
Signal Ground
Data Set Ready
Request To Send
8
9
CTS
RING
<–
<–
Clear To Send
Ring Indicator
Related
Documentation
•
M320 Connector Interface Panel (CIP) Description on page 13
•
M320 Chassis Description on page 7
•
M320 Craft Interface Description on page 15
•
M320 Site Preparation Checklist Requirements on page 85
Copyright © 2015, Juniper Networks, Inc.
117
M320 Multiservice Edge Router Hardware Guide
118 Copyright © 2015, Juniper Networks, Inc.
PART 3
Initial Installation and Configuration
•
Installation Overview on page 121
•
Unpacking the M320 on page 123
•
Installing the Mounting Hardware on page 127
•
Installing the M320 With a Mechanical Lift on page 135
•
Installing the M320 Without a Mechanical Lift on page 143
•
Connecting the M320 to Ground on page 161
•
Connecting the M320 to External Devices on page 163
•
Providing Power to the M320 on page 173
•
Configuring the Junos OS Software on page 179
Copyright © 2015, Juniper Networks, Inc.
119
M320 Multiservice Edge Router Hardware Guide
120 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 14
Installation Overview
•
M320 Router Installation Summary on page 121
M320 Router Installation Summary
After you have prepared your installation site as described in
Checklist Requirements” on page 85
, you are ready to unpack and install the router. It is important to proceed through the installation process in the following order:
1.
Review the safety guidelines explained in
“General Safety Guidelines for Juniper
Networks Devices” on page 315 .
2.
Unpack the router and verify the parts received.
3.
Install the mounting hardware.
See
“Installing the M320 Mounting Hardware for a Four-Post Rack or Cabinet” on page 127
or
“Installing the M320 Mounting Hardware for Open-Frame Racks” on page 130
.
4.
Install the chassis.
See
“Installing the M320 Chassis Using a Mechanical Lift” on page 136
or
“Installing the M320 Chassis in the Rack Manually” on page 151 .
5.
Perform the initial system startup as described in
“Initially Configuring the M320
.
Related
Documentation
•
M320 Installation Safety Guidelines on page 323
Copyright © 2015, Juniper Networks, Inc.
121
M320 Multiservice Edge Router Hardware Guide
122 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 15
Unpacking the M320
•
Tools and Parts Required to Unpack the M320 Router on page 123
•
Unpacking the M320 Router on page 123
•
Verifying the M320 Router Parts Received on page 125
Tools and Parts Required to Unpack the M320 Router
To unpack the router and prepare for installation, you need the following tools:
• Phillips (+) screwdriver, number 2
•
1/2-in. or 13-mm open-end or socket wrench to remove bracket bolts from the shipping pallet
• Blank panels to cover any slots not occupied by a component
Related
Documentation
•
Unpacking the M320 Router on page 123
Unpacking the M320 Router
The router is shipped in a wooden crate. A wooden pallet forms the base of the crate.
The router chassis is bolted to this pallet. Quick Start installation instructions and a cardboard accessory box are also included in the shipping crate.
The shipping crate measures 50 in. (127 cm) high, 30 in. (76.2 cm) wide, and 41 in. (104 cm) deep. The total weight of the crate containing the router and accessories can range from
582 lb (267 kg) to 650 lb (295 kg).
To unpack:
NOTE: The router is maximally protected inside the shipping crate. Do not unpack it until you are ready to begin installation.
Copyright © 2015, Juniper Networks, Inc.
123
M320 Multiservice Edge Router Hardware Guide
1.
Move the shipping crate to a staging area as close to the installation site as possible, where you have enough room to remove the components from the chassis. While the chassis is bolted to the pallet, you can use a forklift or pallet jack to move it.
2.
Position the shipping crate with the arrows pointing up.
3.
Open all the latches on the shipping crate.
4.
Remove the front door of the shipping crate cover and set it aside.
5.
Slide the remainder of the shipping crate cover off the pallet.
6.
Remove the foam covering the top of the router.
7.
Remove the accessory box and the Quick Start documentation.
8.
Verify the parts received.
9.
Remove the vapor corrosion inhibitor (VCI) packs attached to the pallet, being careful not to break the VCI packs open.
10.
To remove the brackets holding the chassis on the pallet, use a 1/2-in. socket wrench and a number 2 Phillips screwdriver to remove the bolts and screws from the brackets.
11.
Store the brackets and bolts inside the accessory box.
12.
Save the shipping crate cover, pallet, and packing materials in case you need to move or ship the router at a later time.
13.
Proceed with the installation.
Figure 32: Contents of the Shipping Crate
124
Related
Documentation
•
Verifying the M320 Router Parts Received on page 125
•
Installing the M320 Chassis Using a Mechanical Lift on page 136
•
Installing the M320 Chassis in the Rack Manually on page 151
Copyright © 2015, Juniper Networks, Inc.
Chapter 15: Unpacking the M320
Verifying the M320 Router Parts Received
A packing list is included in each shipment. Check the parts in the shipment against the items on the packing list. The packing list specifies the part numbers and descriptions of each part in your order.
If any part is missing, contact a customer service representative.
A fully configured router contains the router chassis with installed components, listed in
, and an accessory box, which contains the parts listed in
. The parts shipped with your router can vary.
Table 71: M320 Router Parts List for a Fully Configured Router
Component Quantity
Cable cover
Cable guards
Chassis, including midplane, craft interface, and rack-mounting brackets
FPCs
1
2 upper, 2 lower
1
Up to 8
PICs
SIBs
Routing Engines
CBs
Power supplies
CIP
Front fan tray
Rear fan tray
Front air filter
Rear air filter
Quick start installation instructions
Large mounting shelf
Small mounting shelf
1
1
1
1
1
1
1
4
1
Up to 4 per FPC
4
1 or 2
1 or 2
Copyright © 2015, Juniper Networks, Inc.
125
M320 Multiservice Edge Router Hardware Guide
Table 71: M320 Router Parts List for a Fully Configured Router (continued)
Component Quantity
Spacer bars
Blank panels for slots without components installed
2
One blank panel for each slot not occupied by a component
Table 72: M320 Router Accessory Box Parts List
Part Quantity
Affidavit for T1 connection
Connectors for alarm relay cables
DB-9 (male) to DB-25 (female) adapter
ESD wrist strap with cable
1
1
1
2
Ethernet cable, 15-ft length, to connect Routing Engine to management device
1
PCMCIA card holder and hook-and-loop fasteners (male and female)
1 of each
DC Power and grounding cable lugs
Read me first document
Screws to fasten grounding cable to chassis
Screws to mount chassis
9
1
2
Bag of 14
Serial cable, 6-ft length, to connect Routing Engine to management console
Software license agreement
Washers for grounding cable lug
1
1
2
Related
Documentation
•
M320 Chassis Description on page 7
•
Unpacking the M320 Router on page 123
126 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 16
Installing the Mounting Hardware
•
Installing the M320 Mounting Hardware for a Four-Post Rack or Cabinet on page 127
•
Installing the M320 Mounting Hardware for Open-Frame Racks on page 130
Installing the M320 Mounting Hardware for a Four-Post Rack or Cabinet
To prepare to install the M320 router in a four-post rack or cabinet, you install the large shelf and the spacer bars on the front rail, and the small mounting shelf on the rear rail
(see
. You also remove the adjustable center-mounting brackets from the chassis.
1.
Installing Cage Nuts (If Needed) for M320 Four-Post Racks or Cabinets on page 127
2.
Installing the Large Mounting Shelf for M320 Four-Post Racks or Cabinets on page 128
3.
Installing the Small Mounting Shelf for M320 Four-Post Racks or Cabinets on page 129
4.
Removing the Adjustable Center-Mounting Brackets for M320 Four-Post Racks or
Installing Cage Nuts (If Needed) for M320 Four-Post Racks or Cabinets
For racks without threaded holes, you must install cage nuts in the locations specified in
Table 73 on page 127 . To install the cage nuts:
1.
On the front rack rails, install cage nuts in the holes specified for the large shelf and the spacer bars.
2.
On the rear rack rails, install cage nuts in the holes specified for the small shelf.
specifies the holes in which you insert mounting screws (an X indicates a mounting hole location), and cage nuts if needed. The hole distances are relative to one of the standard U divisions on the rack. The bottom of all mounting shelves is at 0.04 in. (0.02 U) above a U division.
Table 73: Four-Post or Cabinet Rack Mounting Hole Locations
Hole Distance Above U Division
Large
Shelf
Spacer
Bars
Small
Shelf
51 29.51 in. (74.9 cm) 16.86 U
X
Copyright © 2015, Juniper Networks, Inc.
127
M320 Multiservice Edge Router Hardware Guide
42
33
30
Table 73: Four-Post or Cabinet Rack Mounting Hole Locations (continued)
Hole Distance Above U Division
Large
Shelf
Spacer
Bars
Small
Shelf
X 24.26 in. (61.6 cm)
19.01 in. (48.3 cm)
17.26 in. (43.8 cm)
13.86 U
10.86 U
9.86 U
X
X
24
15
13.76 in. (34.9 cm)
8.51 in. (21.6 cm)
7.86 U
4.86 U
X
X
X 6
3
3.26 in. (8.3 cm)
1.51 in. (3.8 cm)
1.86 U
0.86 U
X
X
X 2
1
0.88 in. (2.2 cm)
0.25 in. (0.6 cm)
0.50 U
0.14 U
X
Installing the Large Mounting Shelf for M320 Four-Post Racks or Cabinets
To install the large mounting shelf:
1.
On the front of each front rack rail, partially insert a mounting screw into the lowest hole.
2.
Install the large shelf on the front rack rails. Rest the bottom slot of each flange on a mounting screw.
3.
Partially insert a mounting screw into the top hole in each flange of the large shelf.
4.
Tighten all the screws completely.
5.
The router is shipped with each spacer bar attached to the rear of each front-mounting flange. Remove each spacer bar by removing the seven screws that fasten the spacer bar to the front-mounting flange.
6.
Place one of the spacer bars over an flange of the installed large shelf. Position the notch in the rear of the spacer bar so the upper part of the bar is flush with the rack rail and the lower part is flush with the flange of the shelf.
7.
Insert a mounting screw into each of the nonthreaded holes in the recesses of the spacer bar to secure the spacer bar.
8.
Repeat Steps
and
for the other spacer bar.
9.
Tighten all the screws completely.
128 Copyright © 2015, Juniper Networks, Inc.
Chapter 16: Installing the Mounting Hardware
Figure 33: Installing the Mounting Hardware for a Four-Post Rack or
Cabinet
Installing the Small Mounting Shelf for M320 Four-Post Racks or Cabinets
1.
On the back of each rear rack rail, partially insert a mounting screw into the lowest hole.
2.
Install the small shelf on the back rack rails. Rest the bottom slot of each flange on a mounting screw. The small shelf installs on the back of the rear rails, extending toward the center of the rack. The bottom of the small shelf should align with the bottom of the large shelf.
3.
Partially insert screws into the open holes in the flanges of the small shelf.
4.
Tighten all the screws completely.
Removing the Adjustable Center-Mounting Brackets for M320 Four-Post Racks or Cabinets
Two adjustable center-mounting brackets attached to the center of the chassis (in the mounting holes closest to the rear of the chassis). but are needed only for center-mounting in an open-frame rack. Before installing the M320 router in a four-post rack or cabinet, you must remove the adjustable center-mounting brackets.
Copyright © 2015, Juniper Networks, Inc.
129
M320 Multiservice Edge Router Hardware Guide
To remove the adjustable center-mounting brackets:
1.
Loosen the three screws at the top and bottom of each bracket (see
2.
Remove the center-mounting bracket.
Figure 34: Center-Mounting Bracket Removal
Related
Documentation
•
M320 Site Preparation Checklist Requirements on page 85
Installing the M320 Mounting Hardware for Open-Frame Racks
To prepare to center-mount the router in an open-frame rack, you install both the large and small mounting shelves. The small mounting shelf and adjustable center-mounting brackets are needed only if you are center-mounting the router. To prepare to front-mount the router in an open-frame rack, install the large mounting shelf on the rack.
Two adjustable center-mounting brackets are attached to the center of the chassis (in the mounting holes closest to the rear of the chassis). Optionally, you can move the adjustable center-mounting brackets to any of 11 positions on the side of the chassis.
The spacer bars are not needed to center-mount the chassis; however, you can leave them attached to the front-mounting flanges.
130 Copyright © 2015, Juniper Networks, Inc.
Chapter 16: Installing the Mounting Hardware
The mounting holes for the adjustable center-mounting brackets are spaced
0.984 in. (25 mm) apart. The adjustable center-mounting brackets have holes for rack-mounting screws, spaced at 3.5 in. (8.89 cm).
1.
Installing Cage Nuts (If Needed) for M320 Open Frame Racks on page 131
2.
Installing the Large Mounting Shelf for the M320 Open-Frame Racks on page 132
3.
Installing the Small Mounting Shelf for the M320 Open-Frame Racks on page 132
4.
Moving the Adjustable Center-Mounting Brackets for M320 Open-Frame
Installing Cage Nuts (If Needed) for M320 Open Frame Racks
For racks without threaded holes, you must install cage nuts in the locations specified in
. To install the cage nuts:
1.
On the front rack rails, install cage nuts in the holes specified for the large shelf.
2.
On the rear rack rails, install cage nuts in the holes specified for the small shelf.
For an open-frame rack,
specifies the holes in which you insert mounting screws (an X indicates a mounting hole location), and cage nuts if needed.
The hole distances are relative to one of the standard “U” divisions on the rack. For reference, the bottom of all mounting shelves is at 0.04 in. (0.02 U) above a U division.
Table 74: Open-Frame Rack Mounting Hole Locations
Hole Distance Above “U” Division Large Shelf Small Shelf
X 30
27
24
17.26 in. (43.8 cm) 9.86 U
15.51 in. (39.4 cm) 8.86 U
13.76 in. (34.9 cm) 7.86 U
X
X
X 21
18
12.01 in. (30.5 cm) 6.86 U
10.26 in. (26.0 cm) 5.86 U
X
X 15
12
8.51 in. (21.6 cm)
6.76 in. (17.1 cm)
4.86 U
3.86 U
X
X 9
6
3
5.01 in. (12.7 cm)
3.26 in. (8.3 cm)
1.51 in. (3.8 cm)
2.86 U
1.86 U
0.86 U
X
X
X
X
X 2
1
0.88 in. (2.2 cm)
0.25 in. (0.6 cm)
0.50 U
0.14 U
X
Copyright © 2015, Juniper Networks, Inc.
131
M320 Multiservice Edge Router Hardware Guide
Installing the Large Mounting Shelf for the M320 Open-Frame Racks
1.
On the rear of each rack rail, partially insert a mounting screw into the lowest hole specified in
for the large shelf.
2.
Install the large shelf on the rack. Rest the bottom slot of each flange on a mounting screw.
3.
Partially insert screws into the open holes in the flanges of the large shelf.
Figure 35: Installing the Mounting Hardware for a Center-Mount
Open-Frame Rack
Installing the Small Mounting Shelf for the M320 Open-Frame Racks
To install the small mounting shelf:
1.
On the front of each rack rail, partially insert a mounting screw into the lowest hole specified in
for the small shelf.
2.
Install the small shelf on the rack. Rest the bottom slot of each flange on a mounting screw. The small shelf installs on the front of the rails, extending away from the rack.
The bottom of the small shelf should align with the bottom of the large shelf
132 Copyright © 2015, Juniper Networks, Inc.
Chapter 16: Installing the Mounting Hardware
3.
Partially insert screws into the open holes in the flanges of the small shelf.
4.
Tighten all the screws completely.
Moving the Adjustable Center-Mounting Brackets for M320 Open-Frame Racks
The router has two adjustable center-mounting brackets that are initially attached to the mounting holes closest to the rear of the chassis. You can move the pair of adjustable center-mounting brackets to one of 11 positions on the side of the chassis. The mounting holes for connecting the mounting brackets to the chassis are spaced 0.984 in. (25 mm) apart.
To move the adjustable center-mounting brackets to a different location on the side of the chassis:
1.
Loosen the three screws at the top and bottom of each bracket (see
2.
Align each mounting bracket with the mounting holes on the chassis that correspond to your rack mounting option.
3.
Insert the three screws at the top and bottom of each mounting bracket, tightening each partway.
4.
Tighten all the screws completely.
Figure 36: Center-Mounting Bracket Removal
Copyright © 2015, Juniper Networks, Inc.
133
M320 Multiservice Edge Router Hardware Guide
Related
Documentation
•
M320 Site Preparation Checklist Requirements on page 85
134 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 17
Installing the M320 With a Mechanical Lift
•
Overview of Installing the M320 Chassis Using a Mechanical Lift on page 135
•
Tools Required to Install the M320 Chassis Using a Mechanical Lift on page 136
•
Installing the M320 Chassis Using a Mechanical Lift on page 136
•
Installing the M320 Cable Guards on page 140
Overview of Installing the M320 Chassis Using a Mechanical Lift
Because of the M320 router’s size and weight—up to 439 lb (199.6 kg) depending on the configuration—we strongly recommend that you install the router using a mechanical lift.
1.
Verify that the following tasks have been completed:
•
“Installing the M320 Mounting Hardware for Open-Frame Racks” on page 130
or
Installing the M320 Mounting Hardware for a Four-Post Rack or Cabinet on page 127
•
Unpacking the M320 Router on page 123
2.
Gather the tools required to install the router.
See
“Tools Required to Install the M320 Chassis Using a Mechanical Lift” on page 136
3.
Remove the power supplies.
See
“Removing the M320 Power Supplies” on page 144
.
4.
Attach the installation handle.
See
“Attaching the Installation Handle to the M320 Chassis” on page 136 .
5.
Mount the chassis in the rack or cabinet.
See
“Mounting the M320 Chassis Using a Mechanical Lift” on page 138 .
6.
Remove the installation handle, and reinstall the power supplies.
See
“Removing the M320 Installation Handle and Reinstalling the Power Supplies” on page 139
.
7.
Optionally, install the M320 cable guards.
See
“Installing the M320 Cable Guards” on page 140 .
Copyright © 2015, Juniper Networks, Inc.
135
M320 Multiservice Edge Router Hardware Guide
Tools Required to Install the M320 Chassis Using a Mechanical Lift
To install the T320 chassis using a mechanical lift, you need the following tools:
• Mechanical lift
•
Phillips (+) screwdrivers, number 2
Related
Documentation
•
M320 Installation Safety Guidelines on page 323
•
M320 Cabinet Size and Clearance Requirements on page 88
•
M320 Chassis Description on page 7
Installing the M320 Chassis Using a Mechanical Lift
Because of the router's size and weight—up to 439 lb (199.6 kg) depending on the configuration—we strongly recommend that you install the router using a mechanical lift.
NOTE: To avoid harm to yourself or the router as you install and maintain it, follow the guidelines for working with and near electrical equipment, as well as the safety procedures for working with routers. However, providing an exhaustive set of guidelines for working with electrical equipment is beyond the scope of this documentation.
1.
Attaching the Installation Handle to the M320 Chassis on page 136
2.
Mounting the M320 Chassis Using a Mechanical Lift on page 138
3.
Removing the M320 Installation Handle and Reinstalling the Power Supplies on page 139
Attaching the Installation Handle to the M320 Chassis
To assist you with the installation of the router, attach the installation handle over the three lowest power supply slots of the chassis. To remove the corresponding power supplies and attach the handle:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Switch the circuit breaker on the power supply faceplate to the off position (O). We recommend this even though the power supplies are not connected to power sources.
3.
Loosen the captive screw on each side of the power supply faceplate completely.
4.
Grasp the flange on each side of the power supply faceplate, placing your hand between the flange and the chassis.
5.
Pull firmly to start removing the power supply. Slide it halfway out of the chassis (see
, which shows the removal of a DC power supply).
136 Copyright © 2015, Juniper Networks, Inc.
Chapter 17: Installing the M320 With a Mechanical Lift
6.
Place one hand underneath the power supply to support it, and slide it completely out of the chassis.
CAUTION: Each power supply weighs approximately 10 lb (4.5 kg). Be prepared to support the full weight of the power supply as you remove it from the router.
7.
Repeat the procedure for the remaining power supplies.
8.
Attach the installation handle by tightening the captive screws of the handle into the holes previously occupied by the captive screws of the power supplies in slots PEM1 and PEM3 (see
).
Figure 37: Removing an M320 Power Supply Before Installing the
Installation Handle
Figure 38: Attaching the M320 Installation Handle
Copyright © 2015, Juniper Networks, Inc.
137
M320 Multiservice Edge Router Hardware Guide
Mounting the M320 Chassis Using a Mechanical Lift
CAUTION: Before front-mounting the router in a rack, have a qualified technician verify that the rack is strong enough to support the router's weight and is adequately supported at the installation site.
To install the router using a lift (see
):
1.
Ensure that the rack is in its permanent location and is secured to the building. Ensure that the installation site allows adequate clearance for both airflow and maintenance.
For details, see
“M320 Clearance Requirements” on page 91 .
2.
Load the router onto the lift, making sure it rests securely on the lift platform.
CAUTION: Do not lift the router using the craft interface, installation handle, or the handles on top of the chassis. Use these handles only to help position the router.
3.
Using the lift, position the router in front of the rack or cabinet, centering it in front of the mounting shelves.
4.
Lift the chassis approximately 0.75 in. above the surface of the mounting shelves and position it as close as possible to the shelves.
5.
Carefully slide the router onto the mounting shelves so that the bottom of the chassis and the mounting shelves overlap by approximately 2 inches.
6.
With one person pulling on the installation handle from the rear of the rack or cabinet while another person pushes on the front-mounting flanges, slide the router onto the mounting shelves until the mounting brackets or front-mounting flanges contact the rack rails or spacer bars (depending on your type of installation). The shelves ensure that the holes in the mounting brackets and the front-mounting flanges of the chassis align with the holes in the rack rails.
7.
Move the lift away from the rack.
8.
If you are installing the router in a four-post rack or cabinet, install a mounting screw and a cage nut into each of the holes aligned with the threaded holes in the spacer bars. If you are installing the router in an open-frame rack, install a mounting screw into each of the open mounting holes aligned with the rack, starting from the bottom.
9.
Visually inspect the alignment of the router. If the router is installed properly in the rack, all the mounting screws on one side of the rack should be aligned with the mounting screws on the opposite side and the router should be level.
138 Copyright © 2015, Juniper Networks, Inc.
Chapter 17: Installing the M320 With a Mechanical Lift
Figure 39: Installing the M320 Router in the Rack
NOTE: This illustration depicts the router being installed in an open-frame rack.
Removing the M320 Installation Handle and Reinstalling the Power Supplies
After you have installed the router, remove the installation handle and reinstall the power supplies in the chassis, starting from the bottom (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws on the installation handle completely, and remove the handle from the chassis.
3.
Switch the circuit breaker on the power supply faceplate to the off position (O).
4.
Using both hands, slide the power supply into the chassis until you feel resistance.
5.
Firmly push the power supply into the chassis until it comes to a stop. The power supply faceplate should be flush with any adjacent power supply faceplates.
Copyright © 2015, Juniper Networks, Inc.
139
M320 Multiservice Edge Router Hardware Guide
6.
Tighten the captive screws on each side of the power supply faceplate to secure the power supply in the chassis.
7.
Repeat the procedure for the remaining power supplies.
Figure 40: Reinstalling an M320 Power Supply
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
M320 Installation Safety Guidelines on page 323
•
M320 Chassis Description on page 7
•
M320 Cabinet Size and Clearance Requirements on page 88
•
M320 Site Preparation Checklist Requirements on page 85
•
General Safety Guidelines for Juniper Networks Devices on page 315
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 335
•
General Electrical Safety Warnings for Juniper Networks Devices on page 341
Installing the M320 Cable Guards
After the chassis is installed in the rack or cabinet, you can install the four cable guards.
The cable guards protect the PIC and CIP cables from rubbing against the front edges of the chassis.
To install the cable guards (see
):
1.
Place one of the upper cable guards over one of the front-mounting flanges of the chassis, aligning the top of the cable guard with the top of the flange. Each of the three captive screws on the guard should be aligned with a corresponding standoff on the flange.
2.
Tighten each of the three captive screws partway on the cable guard.
3.
Tighten each of the three captive screws completely.
4.
Repeat Steps
through
for the other upper cable guard.
140 Copyright © 2015, Juniper Networks, Inc.
Chapter 17: Installing the M320 With a Mechanical Lift
5.
Place one of the lower cable guards over one of the front-mounting flanges of the chassis, aligning the cable guard with the standoffs on the flange. Each of the two captive screws on the guard should be aligned with a corresponding hole in the flange.
6.
Tighten each of the two captive screws partway on the cable guard.
7.
Tighten each of the two captive screws completely.
8.
Repeat Steps
through
for the other lower cable guard.
Figure 41: Installing the M320 Cable Guards
Related
Documentation
•
M320 Cable Management System Description on page 12
•
M320 Installation Safety Guidelines on page 323
•
M320 Chassis Description on page 7
•
M320 Cabinet Size and Clearance Requirements on page 88
Copyright © 2015, Juniper Networks, Inc.
141
M320 Multiservice Edge Router Hardware Guide
142 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 18
Installing the M320 Without a Mechanical
Lift
•
Tools and Parts Required to Install the M320 Chassis Without a Mechanical
•
Removing M320 Components from the Chassis on page 143
•
Installing the M320 Chassis in the Rack Manually on page 151
•
Reinstalling M320 Components in the Chassis on page 153
•
Installing the M320 Cable Guards on page 159
Tools and Parts Required to Install the M320 Chassis Without a Mechanical Lift
To install the chassis, you need the following tools and parts:
• Phillips (+) screwdrivers, numbers 1 and 2
• 7/16-in. (11 mm) socket wrench for the DC power supply
•
3/8-in. nut driver for the cable management system
•
ESD grounding wrist strap
Related
Documentation
•
M320 Site Preparation Checklist Requirements on page 85
•
Removing M320 Components from the Chassis on page 143
Removing M320 Components from the Chassis
•
Removing the M320 Power Supplies on page 144
•
Removing the M320 SIBs on page 145
•
Removing the M320 CBs on page 146
•
Removing the M320 Rear Fan Tray on page 146
•
Removing the M320 Cable Management System on page 148
•
Removing the M320 Front Fan Trays on page 148
•
Removing the M320 FPCs on page 149
Copyright © 2015, Juniper Networks, Inc.
143
M320 Multiservice Edge Router Hardware Guide
Removing the M320 Power Supplies
The power supplies are located at the rear of the chassis below the SIBs. Each power supply weighs approximately 10 lb (4.5 kg).
Remove the upper power supply first and finish with the lowest power supply. To remove the AC or DC power supplies:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Switch the circuit breaker on the power supply faceplate to the off position (O). We recommend this even though the power supplies are not connected to power sources.
3.
Loosen the captive screw on each side of the power supply faceplate completely.
4.
Grasp the flange on each side of the power supply faceplate, placing your hand between the flange and the chassis.
5.
Pull firmly to start removing the power supply. Slide it halfway out of the chassis (see
, which shows the removal of DC power supplies).
6.
Place one hand underneath the power supply to support it, and slide it completely out of the chassis.
CAUTION: Each power supply weighs approximately 10 lb (4.5 kg). Be prepared to support the full weight of the power supply as you remove it from the router.
7.
Repeat the procedure for each of the remaining power supplies.
Figure 42: Removing a Power Supply Before Installing the Router
144 Copyright © 2015, Juniper Networks, Inc.
Chapter 18: Installing the M320 Without a Mechanical Lift
Removing the M320 SIBs
Two to four SIBs are installed in the router. The SIBs are located in the rear of the chassis in the slots marked SIB0 through SIB3. SIBs are hot-insertable and hot-removable. Each
SIB weighs approximately 4 lb (1.8 kg).
To remove a SIB (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on each side of the SIB faceplate.
4.
Flip the ejector handles outward to unseat the SIB.
5.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of the way out of the chassis.
6.
Place one hand underneath the SIB to support it, and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
Figure 43: Removing a SIB
Copyright © 2015, Juniper Networks, Inc.
145
M320 Multiservice Edge Router Hardware Guide
Removing the M320 CBs
The router can have one or two CBs. They are located in the upper rear of the chassis in the slots marked CB0 and CB1. Each CB weighs approximately 3.4 lb (1.5 kg).
To remove the CBs (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Loosen the captive screws on the ejector handles on both sides of the CB faceplate.
4.
Flip the ejector handles outward to unseat the CB.
5.
Grasp the ejector handles, and slide the CB about halfway out of the chassis.
6.
Place one hand underneath the CB to support it, and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
7.
Repeat the procedure for the second CB.
Figure 44: Removing a CB
Removing the M320 Rear Fan Tray
The rear fan tray is mounted vertically on the right side of the rear of the chassis. The rear fan tray contains seven fans. The fan tray weighs about 8.4 lb (3.8 kg).
CAUTION: To maintain proper cooling, do not operate the router with the rear fan tray removed for more than 1 minute.
146 Copyright © 2015, Juniper Networks, Inc.
Chapter 18: Installing the M320 Without a Mechanical Lift
To remove the rear fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the top and bottom of the fan tray faceplate, using a
Phillips (+) screwdriver, number 2.
3.
Grasp the handle and pull the fan tray halfway out of the chassis.
4.
When the fans stop spinning, place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
Figure 45: Removing the Rear Fan Tray
Copyright © 2015, Juniper Networks, Inc.
147
M320 Multiservice Edge Router Hardware Guide
Removing the M320 Cable Management System
The cable management system is located below the FPC card cage. The cable management system weighs approximately 5 lb (2.3 kg).
To remove the cable management system:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Using a 3/8-in. nut driver, unscrew the nuts on the corners of the cable management system.
3.
Grasp the bottom of the cable management system and pull it straight out from the studs on the front of the chassis.
Removing the M320 Front Fan Trays
The upper front fan tray is located above the FPC card cage, and the lower front fan tray is located below the air filter. Each fan tray weighs about 11 lb (5.1 kg).
To remove the front fan trays (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screw on each side of the faceplate of one of the fan trays.
3.
Grasp the handles and pull the fan tray until it stops.
4.
Press the tabs on both sides of the fan tray and pull the fan tray halfway out of the chassis.
5.
Place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
6.
Repeat the procedure to remove the remaining front fan tray.
148 Copyright © 2015, Juniper Networks, Inc.
Figure 46: Removing a Front Fan Tray
Chapter 18: Installing the M320 Without a Mechanical Lift
Removing the M320 FPCs
The router holds up to eight FPCs, which are installed vertically in the front of the router.
The FPCs are hot-insertable and hot-removable. An empty FPC1 or FPC2 weighs
15 lb (6.8 kg), and an empty FPC3 weighs 16 lb (7.3 kg). A fully configured FPC can weigh up to 29 lb (13.2 kg)
Each FPC slot not occupied by an FPC must be covered by an FPC blank panel. An FPC blank panel weighs 7.7 lb (3.5 kg).
To remove an FPC (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Before removing the FPCs, record their location in the chassis so that you can reinstall each FPC in the correct slot
4.
Simultaneously turn both the ejector handles counterclockwise to unseat the FPC.
5.
Grasp the handles and slide the FPC straight out of the card cage halfway.
6.
Place one hand around the front of the FPC (the PIC housing) and the other hand under it to support it. Slide the FPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: The weight of the FPC is concentrated in the back end. Be prepared to accept the full weight—up to 29 lb (13.2 kg)—as you slide the
FPC out of the chassis.
When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
Copyright © 2015, Juniper Networks, Inc.
149
M320 Multiservice Edge Router Hardware Guide
Do not stack FPCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
7.
Repeat the procedure for each remaining FPC.
Figure 47: Removing an FPC
150
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
M320 Flexible PIC Concentrator (FPC) Description on page 49
•
Removing the M320 Power Supplies on page 144
•
Removing the M320 SIBs on page 145
•
Removing the M320 CBs on page 146
•
Removing the M320 FPCs on page 149
•
M320 Cooling System Description on page 21
Copyright © 2015, Juniper Networks, Inc.
Chapter 18: Installing the M320 Without a Mechanical Lift
Installing the M320 Chassis in the Rack Manually
CAUTION: If you are installing two routers in one rack, install the lower one first. Installing a router in the upper position in a rack or cabinet requires a lift.
CAUTION: Before front-mounting the router in a rack, have a qualified technician verify that the rack is strong enough to support the router's weight and is adequately supported at the installation site.
Lifting the chassis and mounting it in a rack requires three people. The empty chassis weighs approximately 142 lb (64.7 kg).
To install the chassis in the rack (see
):
1.
Ensure that the rack is in its permanent location and is secured to the building. Ensure that the installation site allows adequate clearance for both airflow and maintenance.
For details, see
“M320 Site Preparation Checklist Requirements” on page 85
.
2.
Attach the installation handle by tightening the captive screws of the handle into the holes previously occupied by the captive screws of the power supplies in slots PEM1 and PEM3 (see
). Tighten the screws, using a Phillips (+) screwdriver, number 2.
Figure 48: Attaching the Installation Handle
3.
Position the router in front of the rack or cabinet, centering it in front of the mounting shelves. Use a pallet jack if one is available.
4.
With one person on each side and one person in the front, hold onto the bottom of the chassis and carefully lift it onto the large and small (if installed) mounting shelves.
Copyright © 2015, Juniper Networks, Inc.
151
M320 Multiservice Edge Router Hardware Guide
WARNING: To prevent injury, keep your back straight and lift with your legs, not your back. Avoid twisting your body as you lift. Balance the load evenly and be sure that your footing is solid.
5.
With one person pulling on the installation handle from the rear of the rack or cabinet while another person pushes on the front-mounting flanges, slide the router onto the mounting shelves until the mounting brackets or front-mounting flanges contact the rack rails or spacer bars (depending on your type of installation). The shelves ensure that the holes in the mounting brackets and the front-mounting flanges of the chassis align with the holes in the rack rails.
6.
If you are installing the router in a four-post rack or cabinet, install a mounting screw and a cage nut into each of the holes aligned with the threaded holes in the spacer bars. If you are installing the router in an open-frame rack, install a mounting screw into each of the open mounting holes aligned with the rack, starting from the bottom.
7.
Loosen the captive screws on the installation handle completely, and remove the handle from the chassis.
8.
Visually inspect the alignment of the router. If the router is installed properly in the rack, all the mounting screws on one side of the rack should be aligned with the mounting screws on the opposite side and the router should be level.
152 Copyright © 2015, Juniper Networks, Inc.
Chapter 18: Installing the M320 Without a Mechanical Lift
Figure 49: Installing the Router in the Rack
NOTE: This illustration depicts the router being installed in an open-frame rack.
Related
Documentation
•
M320 Installation Safety Guidelines on page 323
•
M320 Router Installation Summary on page 121
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Reinstalling M320 Components in the Chassis
•
Reinstalling an M320 Rear Fan Tray on page 154
•
Reinstalling the M320 CBs on page 155
•
Reinstalling the M320 SIBs on page 155
•
Reinstalling the M320 Power Supplies on page 156
•
Reinstalling the M320 FPCs on page 157
Copyright © 2015, Juniper Networks, Inc.
153
M320 Multiservice Edge Router Hardware Guide
•
Reinstalling M320 Front Fan Trays on page 158
•
Reinstalling the M320 Cable Management System on page 159
Reinstalling an M320 Rear Fan Tray
To reinstall the rear fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Grasp the handle with one hand and place the other hand under the fan tray. Insert the fan tray straight into the chassis.
3.
Tighten the captive screws on the top and bottom of the fan tray faceplate to secure it in the chassis.
Figure 50: Reinstalling the Rear Fan Tray
154 Copyright © 2015, Juniper Networks, Inc.
Chapter 18: Installing the M320 Without a Mechanical Lift
Reinstalling the M320 CBs
To reinstall CBs (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Carefully align the sides of the CB with the guides inside the chassis.
3.
Slide the CB into the chassis, carefully ensuring that it is correctly aligned.
4.
Grasp both ejector handles and press them inward to seat the CB.
5.
Tighten the captive screws on the ejector handles, using a Phillips (+) screwdriver, number 2.
6.
Repeat the procedure to reinstall the remaining CB.
Figure 51: Reinstalling a CB
Reinstalling the M320 SIBs
To reinstall the SIBs (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Place one hand underneath the SIB to support it. With the other hand, hold one of the ejector handles on the SIB faceplate.
3.
Carefully align the sides of the SIB with the guides inside the chassis.
4.
Slide the SIB into the chassis, carefully ensuring that it is correctly aligned.
5.
Grasp both ejector handles and press them inward to seat the SIB.
6.
Tighten the captive screws on the ejector handles.
7.
Repeat the procedure for each of the remaining SIBs.
Copyright © 2015, Juniper Networks, Inc.
155
M320 Multiservice Edge Router Hardware Guide
Figure 52: Reinstalling a SIB
Reinstalling the M320 Power Supplies
Reinstall the lowest power supply first and finish with the upper power supply. To reinstall
AC or DC power supplies (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the installation handle completely, and remove the handle from the chassis.
3.
Switch the circuit breaker on the DC power supply faceplate to the off position (O).
4.
Using both hands, slide the power supply into the chassis until you feel resistance.
5.
Firmly push the power supply into the chassis until it comes to a stop. The power supply faceplate should be flush with any adjacent power supply faceplates.
6.
Tighten the captive screws on each side of the power supply faceplate to secure the power supply in the chassis.
7.
Repeat the procedure for each of the remaining power supplies.
156 Copyright © 2015, Juniper Networks, Inc.
Figure 53: Reinstalling a Power Supply
Chapter 18: Installing the M320 Without a Mechanical Lift
Reinstalling the M320 FPCs
To reinstall FPCs (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Using the list you created when you removed the FPCs, locate the slot in the FPC card cage in which you plan to install the FPC.
3.
Inspect the slots in the FPC card cage to verify that there are no missing or bent pins on the midplane.
4.
Inspect each FPC to verify that the connectors are not misaligned or damaged.
CAUTION: When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
5.
Lift the FPC into place and carefully align first the bottom and top of the FPC with the guides inside the card cage. Be sure the FPC is right-side up, with the components on the right of the FPC.
6.
Gently rest the bottom edge of the FPC on the bottom edge of the slot opening, making contact a short distance forward of the power connector.
CAUTION: Take care not to bend or otherwise damage the power connector prongs.
7.
Slide the FPC all the way into the card cage until you feel resistance.
8.
Starting with the ejector handles on the FPC faceplate nearly horizontal, simultaneously turn both ejector handles clockwise to seat the FPC.
Copyright © 2015, Juniper Networks, Inc.
157
M320 Multiservice Edge Router Hardware Guide
9.
If you are installing a Type 2 FPC or Type 3 FPC, tighten the screws inside the ejector handles to secure the FPC. Do not overtighten them.
10.
Repeat the procedure to reinstall each remaining FPC.
Figure 54: Reinstalling an FPC
Reinstalling M320 Front Fan Trays
To reinstall the standard front fan trays (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Grasp one of the fan trays by its handles and insert it straight into the chassis.
3.
Tighten the captive screw on each side of the fan tray faceplate to secure it in the chassis.
4.
Repeat the procedure to reinstall the remaining fan tray.
158 Copyright © 2015, Juniper Networks, Inc.
Chapter 18: Installing the M320 Without a Mechanical Lift
Figure 55: Reinstalling a Front Fan Tray
Reinstalling the M320 Cable Management System
To reinstall the cable management system:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Position the cable management system on the studs on the lower front of the chassis.
3.
Insert the nuts through the holes in the cable management system onto the studs on the chassis.
4.
Using a 3/8-in. nut driver, tighten the nuts securely.
Related
Documentation
•
Taking the M320 Host Subsystem Offline on page 213
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
Removing the M320 SIBs on page 145
•
Removing the M320 CBs on page 146
•
M320 Cooling System Description on page 21
Installing the M320 Cable Guards
After the chassis is installed in the rack or cabinet, you can install the four cable guards.
The cable guards protect the PIC and CIP cables from rubbing against the front edges of the chassis.
To install the cable guards (see
):
1.
Place one of the upper cable guards over one of the front-mounting flanges of the chassis, aligning the top of the cable guard with the top of the flange. Each of the three captive screws on the guard should be aligned with a corresponding standoff on the flange.
2.
Tighten each of the three captive screws partway on the cable guard.
Copyright © 2015, Juniper Networks, Inc.
159
M320 Multiservice Edge Router Hardware Guide
3.
Tighten each of the three captive screws completely.
4.
Repeat Steps
through
for the other upper cable guard.
5.
Place one of the lower cable guards over one of the front-mounting flanges of the chassis, aligning the cable guard with the standoffs on the flange. Each of the two captive screws on the guard should be aligned with a corresponding hole in the flange.
6.
Tighten each of the two captive screws partway on the cable guard.
7.
Tighten each of the two captive screws completely.
8.
Repeat Steps
through
for the other lower cable guard.
Figure 56: Installing the M320 Cable Guards
160
Related
Documentation
•
M320 Cable Management System Description on page 12
•
M320 Installation Safety Guidelines on page 323
•
M320 Chassis Description on page 7
•
M320 Cabinet Size and Clearance Requirements on page 88
Copyright © 2015, Juniper Networks, Inc.
CHAPTER 19
Connecting the M320 to Ground
•
Tools and Parts Required to Ground the M320 Router on page 161
•
Connecting the M320 Router Grounding Cable on page 161
Tools and Parts Required to Ground the M320 Router
• Grounding cable (which you must provide)
•
Grounding lug (provided with the router)
Figure 57: Grounding Lug
• M6 screws or UNC 1/4-20 screws
•
Electrostatic discharge (ESD) grounding wrist strap
Related
Documentation
•
M320 Chassis Description on page 7
•
M320 Chassis Grounding Cable and Lug Specifications on page 94
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Connecting the M320 Router Grounding Cable
CAUTION: Sub-optimal ground such as ground-loop or ground with high-impedance can result in unexpected FRU shut down. Engage a third party power consultant or certified electrician to ensure optimal grounding.
To meet safety and electromagnetic interference (EMI) requirements and to ensure proper operation, the router must be adequately grounded before power is connected.
Copyright © 2015, Juniper Networks, Inc.
161
M320 Multiservice Edge Router Hardware Guide
Two pairs of threaded inserts (PEM nuts) are provided on the right rear of the chassis for connecting the router to earth ground. The left pair of grounding points fits M6 screws
(European), and the right pair fits UNC 1/4–20 screws (American). The grounding points are spaced at 0.625-in. (15.86-mm) centers. The accessory box shipped with the router includes the cable lug that attaches to the grounding cable (see
Cable and Lug Specifications” on page 94
) and two UNC 1/4–20 screws. For power cord and grounding cable specifications, see
“M320 AC Power Cord Specifications” on page 102 .
CAUTION: Before router installation begins, a licensed electrician must attach a cable lug to the grounding and power cables that you supply. A cable with an incorrectly attached lug can damage the router.
To ground AC and DC powered routers:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Connect the grounding cable to a proper earth ground.
3.
Verify that a licensed electrician has attached the cable lug provided with the router to the grounding cable.
4.
Place the grounding cable lug over the grounding points on the bottom rear of the chassis. The left pair is sized for M6 bolts, and the right pair is sized for UNC 1/4-20 bolts.
5.
Secure the grounding cable lug to the grounding points, first with the washers, then with the screws.
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
General Electrical Safety Warnings for Juniper Networks Devices on page 341
162 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 20
Connecting the M320 to External Devices
•
Tools and Parts Required for M320 Router Connections on page 163
•
Overview of Connecting the M320 Router to Management and Alarm Devices on page 164
•
Connecting the M320 Router to a Management Console or Auxiliary Device on page 165
•
Connecting the M320 Router to a Network for Out-of-Band Management on page 166
•
Connecting the M320 Router to an External Alarm-Reporting Device on page 168
•
Connecting the M320 Router to an External Clocking Device on page 168
•
Connecting PIC Cables to the M320 Router on page 169
Tools and Parts Required for M320 Router Connections
To connect the M320 router to management devices and PICs and to power on the router, you need the following tools and parts:
•
Phillips (+) screwdrivers, numbers 1 and 2
•
2.5-mm flat-blade (-) screwdriver for the DB-9 connectors on the CONSOLE and AUX ports
• 2.5-mm Phillips (+) screwdriver
• 7/16-in. (11 mm) hexagonal-head external drive socket wrench, or nut driver, with a torque range between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm), for tightening nuts to terminal studs on each power supply on a DC-powered router.
• Electrostatic discharge (ESD) grounding wrist strap
Related
Documentation
•
Connecting the M320 Router Grounding Cable on page 161
•
Connecting Power to an AC-Powered M320 Router on page 173
•
Connecting Power to a DC-Powered M320 Router on page 174
•
M320 Power Requirements on page 96
•
Powering On the M320 Router on page 176
Copyright © 2015, Juniper Networks, Inc.
163
M320 Multiservice Edge Router Hardware Guide
Overview of Connecting the M320 Router to Management and Alarm Devices
For management and service operations, you connect the Routing Engine to an external console or management network through ports on the Connector Interface Panel (CIP).
You can also connect the router to external alarm-reporting devices through the alarm relay contacts on the CIP.
After you have installed the router into the rack, attach one or more external devices to the ports on the CIP that connect to the Routing Engines for management and service operations (see
).
Figure 58: Routing Engine Management Ports and Alarm Relay Contacts
164 Copyright © 2015, Juniper Networks, Inc.
Chapter 20: Connecting the M320 to External Devices
Related
Documentation
•
Initially Configuring the M320 Router on page 179
Connecting the M320 Router to a Management Console or Auxiliary Device
To use a system console to configure and manage the Routing Engine, connect it to the appropriate CONSOLE port on the CIP. To use a laptop, modem, or other auxiliary device, connect it to the appropriate AUXILIARY port on the CIP. Both ports accept an RS-232
(EIA-232) serial cable with a DB-9 female connector. One DB-9/DB-9 cable is provided with the router. To connect a device to the CONSOLE port, and another device to the
AUXILIARY port, you must supply another cable.
To connect a management console or auxiliary device:
1.
Turn off the power to the console or auxiliary device.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Connect one end (shown in
) of a serial cable with a DB-9 female connector to the appropriate CONSOLE or AUXILIARY port (see
).
The ports labeled HOST 0 connect to the Routing Engine in the upper Routing Engine slot (RE0), and the ports labeled HOST 1 connect to the Routing Engine in the lower
Routing Engine slot (RE1).
NOTE:
For console devices, configure the serial port to the following values:
• Baud rate—9600
•
Parity—N
•
Data bits—8
• Stop bits—1
• Flow control—none
4.
Using a 2.5-mm flat-blade screwdriver, tighten the screws on the connector.
5.
Attach the other end of the cable to the console or auxiliary device.
Copyright © 2015, Juniper Networks, Inc.
165
M320 Multiservice Edge Router Hardware Guide
Figure 59: Console and Auxiliary Serial Port Connector
Figure 60: Console and Auxiliary Ports on the CIP
Related
Documentation
•
Overview of Connecting the M320 Router to Management and Alarm Devices on page 164
•
M320 Routing Engine Interface Cable and Wire Specifications on page 115
Connecting the M320 Router to a Network for Out-of-Band Management
To connect the Routing Engine to a network for out-of-band management, connect an
Ethernet with RJ-45 connectors to the ETHERNET port on the CIP. One cable is provided with the router.
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Turn off the power to the management device.
3.
Plug one end of the Ethernet cable (
shows the connector) in to the appropriate ETHERNET port on the CIP (see
). The ports labeled HOST 0 connect to the Routing Engine in the upper Routing Engine slot (RE0),
166 Copyright © 2015, Juniper Networks, Inc.
Chapter 20: Connecting the M320 to External Devices and the ports labeled HOST 1 connect to the Routing Engine in the lower Routing
Engine slot (RE1).
4.
Plug the other end of the cable into the network device.
Figure 61: Routing Engine Ethernet Cable Connector
Figure 62: ETHERNET Port on the CIP
HOST
0
ETHERNET
ACT 0
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
HOST
1
ETHERNET
ACT 1
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
RED ALARM
NC
C
NO
NC
C
NO
YELLOW
ALARM
Copyright © 2015, Juniper Networks, Inc.
167
M320 Multiservice Edge Router Hardware Guide
Related
Documentation
•
M320 Routing Engine Interface Cable and Wire Specifications on page 115
•
Overview of Connecting the M320 Router to Management and Alarm Devices on page 164
Connecting the M320 Router to an External Alarm-Reporting Device
To connect the router to external alarm-reporting devices, attach wires to the RED ALARM and YELLOW ALARM relay contacts on the CIP. A system condition that triggers the red or yellow alarm LED on the craft interface also activates the corresponding alarm relay contact.
The terminal blocks that plug into the alarm relay contacts are supplied with the router.
They accept wire of any gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
2
), which is not provided. Use the gauge of wire appropriate for the external device you are connecting.
To connect an external device to an alarm relay contact:
1.
Prepare the required length of wire with gauge between 28-AWG and 14-AWG (0.08
and 2.08 mm
2
).
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
While the terminal block is not plugged into the relay contact, use a 2.5-mm flat-blade screwdriver to loosen the small screws on its side. With the small screws on its side facing left, insert wires into the slots in the front of the block based on the wiring for the external device. Tighten the screws to secure the wire.
4.
Orient the terminal block according to the labels to the left of the appropriate relay contact (NC means “normally closed, C means “common,” and (NO means “normally open”).
5.
Plug the terminal block into the relay contact and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.
6.
Attach the other end of the wires to the external device.
If attaching a reporting device for the other kind of alarm, repeat the procedure.
Related
Documentation
•
Overview of Connecting the M320 Router to Management and Alarm Devices on page 164
•
M320 Routing Engine Interface Cable and Wire Specifications on page 115
Connecting the M320 Router to an External Clocking Device
The M320 router contains two external clock input (EXTERNAL CLOCK INPUTS) ports on each control board (CB) labeled A or B.
168 Copyright © 2015, Juniper Networks, Inc.
Chapter 20: Connecting the M320 to External Devices
To connect the router to external clocking devices, connect a cable with RJ-45 connectors to each external clock input port:
1.
Attach an electrostatic discharge (ESD) grounding trap on your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Plug one end of the RJ-45 cable into the external clock input ports on the front of the
CB.
3.
Plug the other end of the RJ-45 cable into the E1 or T1 external clocking device.
4.
Verify that the LEDs for the external clock inputs are lit steadily green.
5.
Repeat the cabling procedures as needed for the other CB.
6.
Configure the port. See the synchronization statement for M Series and T Series in the
Junos OS Administration Library for Routing Devices.
7.
Issue the show chassis synchronization command to check the status of the port.
user@host> show chassis synchronization
Clock Synchronization Status :
Clock module on CB 0
Current state : master
Current clock state : internal
Selected for : 4 days, 11 hours, 9 minutes, 26 seconds
Selected since : 2012-11-08 02:37:37 PST
Deviation (in ppm) : +0.00
Last deviation (in ppm): +0.01
Clock Synchronization Status :
Clock module on CB 1
Current state : backup
Current clock state : locked to master CB
Selected for : 10 days, 9 hours, 34 minutes, 28 seconds
Selected since : 2012-11-02 05:12:35 PDT
Related
Documentation
•
M320 Control Board (CB) Description on page 45
•
M320 RJ-48 Connector Pinouts for the Control Board External Clock Inputs on page 98
Connecting PIC Cables to the M320 Router
Now connect PICs to the network by plugging in network cable. To connect cable to the
PICs (see
Figure 63 on page 170 , which shows a fiber-optic PIC):
1.
Have ready a length of the type of cable used by the PIC. For cable specifications, see
Supported Network Interface Standards by Transceiver for ACX, M, MX, and T Series
Routers, Network Cable and Transceiver Overview for ACX Series, M Series, and MX
Series Routers, and the M320 Multiservice Edge Router Interface Module Reference.
2.
If the PIC cable connector port is covered by a rubber safety plug, remove the plug.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
Copyright © 2015, Juniper Networks, Inc.
169
M320 Multiservice Edge Router Hardware Guide
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
3.
Insert the cable connector into the cable connector port on the PIC faceplate.
4.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
5.
After you have draped the PIC cables, you can optionally install the cable cover (the cable cover prevents the PIC and CIP cables from being disturbed or snagged. To install the cable cover, insert the upper tabs of the cover into the slots of the upper cable guards, then insert the lower tabs of the cover into the slots of the lower cable guards (see
“Installing the M320 Cable Guards” on page 140 .
Figure 63: Attaching Cable to a PIC
170 Copyright © 2015, Juniper Networks, Inc.
Figure 64: Installing the Cable Cover
Chapter 20: Connecting the M320 to External Devices
Related
Documentation
•
M320 Cable Management System Description on page 12
•
M320 PIC Description on page 54
Copyright © 2015, Juniper Networks, Inc.
171
M320 Multiservice Edge Router Hardware Guide
172 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 21
Providing Power to the M320
•
Connecting Power to an AC-Powered M320 Router on page 173
•
Connecting Power to a DC-Powered M320 Router on page 174
•
Powering On the M320 Router on page 176
•
Powering Off the M320 Router on page 178
Connecting Power to an AC-Powered M320 Router
NOTE: Each power supply must be connected to a dedicated AC power feed and a dedicated 15 A (250 VAC) circuit breaker. For information about AC power specifications, see
“M320 AC Power Electrical Specifications” on page 101
.
To connect the AC power cords to the router, attach the power cords from each AC power source to the AC appliance inlet on the faceplate of each power supply (see
1.
Locate the power cords shipped with the router, which should have a plug appropriate for your geographical location (see
“M320 AC Power Cord Specifications” on page 102
).
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Verify that the source power cabling and the grounding cabling are correct, that they are not touching or blocking access to router components, and that they do not drape where people could trip on them.
4.
Switch the power switch on the power supply faceplate to the off position (O).
5.
Insert the appliance coupler end of a power cord into the appliance inlet on the power supply faceplate.
6.
Remove the cable restraint from the right edge of the power supply faceplate by removing its retainer screw.
7.
Wrap the cable restraint around the power cord, then slide it along the power cord to a position that enables you to reinstall it in the power supply faceplate.
Copyright © 2015, Juniper Networks, Inc.
173
M320 Multiservice Edge Router Hardware Guide
8.
Reinstall the cable restraint by tightening its retainer screw partway into the power supply faceplate.
9.
Carefully pull the AC power cord through the cable restraint until you have the desired amount of slack in the power cord.
10.
Tighten the cable restraint retainer screw to hold the power cord in place.
11.
Insert the power cord plug into an AC power source receptacle. Verify that the power cord does not block access to router components or drape where people could trip on it.
Figure 65: Connecting AC Power to the M320 Router
Related
Documentation
•
M320 AC Power Supplies Description on page 73
•
M320 AC Power Electrical Safety Guidelines on page 345
•
M320 AC Power Electrical Safety Warning on page 346
•
General Electrical Safety Warnings for Juniper Networks Devices on page 341
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Connecting Power to a DC-Powered M320 Router
You connect DC power to the router by attaching power cables from the DC power sources to the terminal studs on the power supply faceplates. To connect power to the router, you must provide grounding and power cables (the cable lugs are supplied with the router). For grounding DC power cable specifications, see
.
174 Copyright © 2015, Juniper Networks, Inc.
Chapter 21: Providing Power to the M320
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
To connect the DC source power cables to the router, for each power supply:
1.
Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point.
3.
Verify that the source power cabling and the grounding cabling are correct, that they are not touching or blocking access to router components, and that they do not drape where people could trip on them.
4.
Switch the circuit breaker on the DC power supply faceplate to the off position (O).
5.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
6.
Remove the nut and washer from each power terminal stud. If no washers and nuts are already installed, they should be in the accessory box.
7.
Attach the lugs on the DC source power cables to the terminal studs.
a.
Attach the lugs on the positive (+) DC source power cables to the terminal studs.
b.
Attach the lugs on the negative (–) DC source power cables to the terminal studs.
Secure each cable lug to the terminal stud, first with a washer, then with a nut. Use a
7/16-in. (11 mm) nut driver or wrench to tighten the nut. Apply between 23 lb-in. (2.6
Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
NOTE: The DC power supplies in slots PEM0 and PEM1 must be powered by dedicated power feeds derived from feed A, and the DC power supplies in slots PEM2 and PEM3 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed
A/B feed redundancy for the system.
8.
Loosen the captive screw on the cable restraint on the right edge of the power supply faceplate.
9.
Route the positive and negative DC power cables through the top and bottom of the cable restraint.
10.
Tighten the cable restraint captive screw to hold the power cables in place.
Copyright © 2015, Juniper Networks, Inc.
175
M320 Multiservice Edge Router Hardware Guide
11.
Verify that the power cabling is correct, that the power cables do no touch or blocki access to Routerrouter components, or drape where people could trip on them.
12.
Replace the clear plastic cover over the terminal studs on the faceplate.
Figure 66: Connecting DC Power to the M320 Router
Related
Documentation
•
M320 DC Power Supplies Description on page 74
•
M320 DC Power Electrical Safety Guidelines on page 346
•
General Electrical Safety Warnings for Juniper Networks Devices on page 341
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Powering On the M320 Router
To power on the router:
1.
Verify that the power supplies are fully inserted in the chassis and that the captive screws on their faceplates are tightened.
2.
For each power supply on an AC-powered router, verify that the source power cord is securely inserted into the appliance inlet. For each power supply on a DC-powered router, verify that the source power cables are connected to the appropriate terminal:
176 Copyright © 2015, Juniper Networks, Inc.
Chapter 21: Providing Power to the M320 the positive (+) source cable to the return terminal (labeled RETURN) and the negative
(–) source cable to the input terminal (labeled –48V).
3.
Verify that an external management device is connected to one of the Routing Engine ports on the CIP (AUX, CONSOLE, or ETHERNET). For more information about connecting management devices, see
“Overview of Connecting the M320 Router to
Management and Alarm Devices” on page 164
.
4.
Turn on the power to the external management device.
5.
Switch the circuit breaker on one of the DC power supplies to the on position (|) and observe the output status LED (OUTPUT OK) on the power supply faceplate. If the power supply is correctly installed and functioning properly, the OUTPUT OK status
LED on the power supply faceplate blinks, then lights steadily approximately 1 minute after you switch the power supply circuit breaker on.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on. After powering on a power supply, wait at least 60 seconds before turning it off.
If the system is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence. If the Routing Engine finishes booting and you need to power off the system again, first issue the CLI request system halt command.
After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the output status LED on the power supply, the show chassis command display, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally.
Ignore error indicators that appear during the first 60 seconds.
6.
Repeat Step
for the remaining power supplies.
NOTE: If any of the output status LEDs do not light steadily, repeat the installation and cabling procedures described in
, and
“Connecting Power to an AC-Powered
or
“Connecting Power to a DC-Powered M320
.
7.
On the external management device connected to the Routing Engine, monitor the startup process to verify that the system has booted properly.
Related
Documentation
•
Powering Off the M320 Router on page 178
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Copyright © 2015, Juniper Networks, Inc.
177
M320 Multiservice Edge Router Hardware Guide
Powering Off the M320 Router
To power off a T320 router:
1.
On the external management device connected to the Routing Engine, issue the request system halt both-routing-engines operational mode command. The command shuts down both Routing Engines cleanly, so their state information is preserved. (If the router contains only one Routing Engine, issue the request system halt command.) user@host> request system halt both-routing-engines
For more information about these commands, see request system halt.
2.
Wait until a message appears on the console confirming that the operating system has halted.
Halt the system ? [yes,no] (no) yes
*** FINAL System shutdown message from root@section2 ***
System going down IMMEDIATELY
Terminated
...
syncing disks... 11 8 done
The operating system has halted.
Please press any key to reboot.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Switch the circuit breakers on each power supply faceplate to the off position (O).
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
178 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 22
Configuring the Junos OS Software
•
Initially Configuring the M320 Router on page 179
Initially Configuring the M320 Router
The M120 router is shipped with the Junos OS preinstalled and ready to be configured when the M120 router is powered on. There are three copies of the software: one on a
CompactFlash card in the Routing Engine, one on a rotating hard disk in the Routing
Engine, and one on a PC Card that can be inserted into the slot in the Routing Engine faceplate.
When the router boots, it first attempts to start the image on the PC Card. If a PC Card is not inserted into the Routing Engine or the attempt otherwise fails, the router next tries the CompactFlash card (if installed), and finally the hard disk.
You configure the router by issuing Junos OS command-line interface (CLI) commands, either on a console device attached to the CONSOLE port on the CIP, or over a telnet connection to a network connected to the ETHERNET port on the CIP.
Gather the following information before configuring the router:
•
Name the router will use on the network
•
Domain name the router will use
• IP address and prefix length information for the Ethernet interface
• IP address of a default router
•
IP address of a DNS server
•
Password for the root user
This procedure connects the router to the network but does not enable it to forward traffic. For complete information about enabling the router to forward traffic, including examples, see the Junos OS configuration guides.
To configure the software:
1.
Verify that the router is powered on.
2.
Log in as the “root” user. There is no password.
Copyright © 2015, Juniper Networks, Inc.
179
M320 Multiservice Edge Router Hardware Guide
180
3.
Start the CLI.
root# cli root@>
4.
Enter configuration mode.
cli> configure
[edit] root@#
5.
Configure the name of the router. If the name includes spaces, enclose the name in quotation marks (“ ”).
[edit] root@# set system host-name host-name
6.
Create a management console user account.
[edit] root@# set system login user user-name authentication plain-text-password
New password: password
Retype new password: password
7.
Set the user account class to super-user.
[edit] root@# set system login user user-name class super-user
8.
Configure the router’s domain name.
[edit] root@# set system domain-name domain-name
9.
Configure the IP address and prefix length for the router’s Ethernet interface.
[edit] root@# set interfaces fxp0 unit 0 family inet address address/prefix-length
10.
Configure the IP address of a backup router, which is used only while the routing protocol is not running.
[edit] root@# set system backup-router address
11.
Configure the IP address of a DNS server.
[edit] root@# set system name-server address
12.
Set the root authentication password by entering either a clear-text password, an encrypted password, or an SSH public key string (DSA or RSA).
[edit] root@# set system root-authentication plain-text-password
New password: password
Retype new password: password or or
[edit] root@# set system root-authentication encrypted-password encrypted-password
Copyright © 2015, Juniper Networks, Inc.
Chapter 22: Configuring the Junos OS Software or
[edit] root@# set system root-authentication ssh-dsa public-key
[edit] root@# set system root-authentication ssh-rsa public-key
13.
(Optional) Configure the static routes to remote subnets with access to the management port. Access to the management port is limited to the local subnet. To access the management port from a remote subnet, you need to add a static route to that subnet within the routing table. For more information about static routes, see the Junos OS Administration Library for Routing Devices.
[edit] root@# set routing-options static route remote-subnet next-hop destination-IP retain no-readvertise
14.
Configure the telnet service at the [edit system services] hierarchy level.
[edit] root@# set system services telnet
15.
(Optional) Display the configuration to verify that it is correct.
[edit] root@# show system { host-name host-name; domain-name domain-name; backup-router address; root-authentication {
authentication-method (password | public-key);
} name-server {
address;
}
} interfaces { fxp0 { unit 0 { family inet { address address/prefix-length;
}
}
}
}
16.
Commit the configuration to activate it on the router.
[edit] root@# commit
17.
(Optional) Configure additional properties by adding the necessary configuration statements. Then commit the changes to activate them on the router.
[edit] root@host# commit
18.
When you have finished configuring the router, exit configuration mode.
Copyright © 2015, Juniper Networks, Inc.
181
M320 Multiservice Edge Router Hardware Guide
[edit] root@host# exit root@host>
NOTE: To reinstall the Junos OS, you boot the router from the removable media. Do not insert the removable media during normal operations. The router does not operate normally when it is booted from the removable media.
When the router boots from the storage media (removable media, CompactFlash card, or hard disk) it expands its search in the /config directory of the routing platform for the following files in the following order: juniper.conf (the main configuration file), rescue.conf
(the rescue configuration file), and juniper.conf.1 (the first rollback configuration file).
When the search finds the first configuration file that can be loaded properly, the file loads and the search ends. If none of the file can be loaded properly, the routing platform does not function properly. If the router boots from an alternate boot device, the Junos
OS displays a message indication this when you log in to the router.
Related
Documentation
•
M320 Chassis Description on page 7
•
M320 Router Description on page 3
•
Powering On the M320 Router on page 176
182 Copyright © 2015, Juniper Networks, Inc.
PART 4
Installing and Replacing Components
•
Overview of Installing and Replacing Components on page 185
•
Replacing Chassis Components on page 189
•
Replacing Cooling System Components on page 203
•
Replacing Host Subsystem Components on page 213
•
Replacing Line Card Components on page 227
•
Replacing Power System Components on page 247
•
Replacing Switch Fabric Components on page 259
Copyright © 2015, Juniper Networks, Inc.
183
M320 Multiservice Edge Router Hardware Guide
184 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 23
Overview of Installing and Replacing
Components
•
M320 Field Replaceable Units on page 185
•
Tools and Parts Required to Replace the M320 Hardware Components on page 186
M320 Field Replaceable Units
Field-replaceable units (FRUs) are router components that can be replaced at the customer site. Replacing most FRUs requires minimal router downtime. The router uses the following types of FRUs:
•
Hot-removable and hot-insertable FRUs—You can remove and replace these components without powering off the router or disrupting the routing functions.
• Hot-pluggable FRUs—You can remove and replace these components without powering down the router, but the routing functions of the system are interrupted when the component is removed.
Before you replace a CB or a Routing Engine, you must take the host subsystem offline.
lists the FRUs for the M320 router.
Copyright © 2015, Juniper Networks, Inc.
185
M320 Multiservice Edge Router Hardware Guide
Table 75: Field-Replaceable Units
Hot-removable and hot-insertable FRUs Hot-pluggable FRUs
Air filters
Craft interface
Flexible PIC Concentrators (FPCs)
Front and rear fan trays
Physical Interface Cards (PICs)
Power supplies
Switch Interface Boards (SIBs)
Backup Control Board (CB)
Backup Routing Engine
Master Control Board (CB) (if nonstop active routing is configured)
Master Routing Engine (if nonstop active routing is configured)
Connector Interface Panel (CIP)
Control Board (CB) (if not redundant)
Routing Engine (if not redundant)
Master Control Board (CB) (if nonstop active routing is not configured)
Master Routing Engine (if nonstop active routing is not configured)
Related
Documentation
•
M320 Chassis Description on page 7
•
Taking the M320 Host Subsystem Offline on page 213
Tools and Parts Required to Replace the M320 Hardware Components
To replace hardware components, you need the tools and parts listed in
Table 76: Tools and Parts Required
Tool or Part Components
7/16-in. (11 mm) nut driver
Blank panels (if component is not reinstalled)
Cables and connectors
DC power supply
CB
FPC
PIC
Routing Engine
SIB
186 Copyright © 2015, Juniper Networks, Inc.
Chapter 23: Overview of Installing and Replacing Components
Table 76: Tools and Parts Required (continued)
Tool or Part Components
Electrostatic bag or antistatic mat CB
FPC
PIC
Routing Engine
SIB
All Electrostatic discharge (ESD) grounding wrist strap
Flat-blade (–) screwdriver Cables and connectors
PIC (in an FPC1)
Serial cable to
AUX or
CONSOLE
Routing Engine port
Fuses Insulated fuse removal tool
Phillips (+) screwdrivers, numbers 1 and 2
Air filter (front or rear)
Cable guards
Cables and connectors
CB
CIP
Craft interface
FPC
Fan tray (front or rear)
PIC
Power supply (AC or DC)
Routing Engine
SIB
Rubber safety cap
Wire cutters
Fiber-optic PIC or PIC cable
Cables and connectors
DC power supply
Copyright © 2015, Juniper Networks, Inc.
187
M320 Multiservice Edge Router Hardware Guide
NOTE: If you have installed the cable cover, you must remove it before you can replace any hardware component or cable in the front of the chassis between the cable management system and the craft interface. To remove the cable cover, pull the lower tabs of the cover out of the slots of the lower cable guards, then pull the upper tabs of the cover out of the slots of the upper cable guards. To install the cable cover, insert the upper tabs of the cover into the slots of the upper cable guards, then insert the lower tabs of the cover into the slots of the lower cable guards (see
“Connecting PIC Cables to the M320 Router” on page 169
).
Related
Documentation
•
M320 Chassis Description on page 7
•
Returning a Hardware Component to Juniper Networks, Inc. on page 307
•
Contacting Customer Support on page 297
188 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 24
Replacing Chassis Components
•
Replacing the M320 CIP on page 189
•
Replacing the M320 Alarm Relay Wires on page 192
•
Replacing an M320 Management Ethernet Cable on page 192
•
Replacing an M320 Console or Auxiliary Cable on page 194
•
Replacing an M320 Craft Interface on page 197
•
Replacing an M320 Fuse on page 199
Replacing the M320 CIP
1.
Removing an M320 CIP on page 189
2.
Installing an M320 CIP on page 190
Removing an M320 CIP
The CIP is located to the left side of the FPC card cage. It houses the Routing Engine interface ports, which accept connections to external management and alarm-reporting devices.
The CIP is hot-pluggable. It weighs approximately 6.8 lb (3.1 kg). When the CIP is removed, you cannot control or communicate with the router using an external device.
To remove the CIP (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis. .
2.
Disconnect any external devices connected to the CIP. For instructions, see
“Removing an M320 Console or Auxiliary Cable” on page 194
,
Ethernet Cable” on page 192 , and “Replacing the M320 Alarm Relay Wires” on page 192
.
3.
Loosen the captive screws at the top and bottom of the CIP faceplate.
4.
Grasp the handle on the CIP faceplate, and carefully pull the CIP straight out of the chassis.
CAUTION: Be sure to slide the CIP straight within the slot to avoid damaging the connector pins on the front of the midplane.
Copyright © 2015, Juniper Networks, Inc.
189
M320 Multiservice Edge Router Hardware Guide
Figure 67: Removing the CIP
Installing an M320 CIP
To install the CIP (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the CIP handle with one hand and hold the bottom edge of the CIP with the other hand to support its weight.
NOTE: The components on the CIP are on the left side of the board, unlike the components of an FPC, which are on the right side. Verify that the components are on the left before inserting the CIP.
3.
Insert the CIP into the leftmost slot of the FPC card cage, carefully aligning the top and bottom of the CIP with the guides in the card cage.
4.
Carefully push the CIP straight into the chassis until it contacts the midplane.
190 Copyright © 2015, Juniper Networks, Inc.
Chapter 24: Replacing Chassis Components
5.
Tighten the screws at the top and bottom of the CIP faceplate.
6.
Reattach any external devices connected to the CIP.
CAUTION: Be sure to slide the CIP straight within the slot to avoid damaging the connector pins on the front of the midplane.
7.
To verify that the CIP is installed correctly, plug an Ethernet cable into the Ethernet port on the CIP. If the host module is operational, the ACTIVE LED blinks to indicate
Ethernet activity. If you can run the CLI, the CIP is installed correctly.
Figure 68: Installing a CIP
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
M320 Routing Engine Description on page 24
•
M320 Connector Interface Panel (CIP) Description on page 13
•
Connecting the M320 Router to a Management Console or Auxiliary Device on page 165
•
M320 Routing Engine Interface Cable and Wire Specifications on page 115
Copyright © 2015, Juniper Networks, Inc.
191
M320 Multiservice Edge Router Hardware Guide
Replacing the M320 Alarm Relay Wires
To connect the router to external alarm-reporting devices, attach wires to the RED and
YELLOW relay contacts on the CIP. A system condition that triggers the red or yellow alarm LED on the craft interface also activates the corresponding alarm relay contact.
The terminal blocks that plug into the alarm relay contacts are supplied with the router.
They accept wire of any gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
2
), which is not provided. Use the gauge of wire appropriate for the external device you are connecting.
To replace the wires connecting to an alarm-reporting device:
1.
Disconnect the existing wire at the external device.
2.
Prepare the required length of replacement wire with gauge between 28-AWG and
14-AWG (0.08 and 2.08 mm
2
).
3.
Using a 2.5-mm flat-blade screwdriver, loosen the small screws on the face of the terminal block and remove the block from the relay contact.
4.
Using the 2.5-mm flat-blade screwdriver, loosen the small screws on the side of the terminal block. Remove existing wires from the slots in the front of the block and insert replacement wires. Tighten the screws to secure the wire.
5.
Plug the terminal block into the relay contact and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.
6.
Attach the other end of the wires to the external device.
Related
Documentation
•
Connecting the M320 Router to an External Alarm-Reporting Device on page 168
•
M320 Connector Interface Panel (CIP) Description on page 13
•
M320 Chassis and Interface Alarm Messages on page 285
Replacing an M320 Management Ethernet Cable
To replace the management Ethernet cable:
1.
Press the tab on the connector and pull the connector straight out of the ETHERNET port.
shows the connector.
2.
Disconnect the cable from the network device.
3.
Plug one end of the replacement cable into the appropriate ETHERNET port. The ports labeled HOST 0 connect to the Routing Engine in the upper Routing Engine slot (RE0), and the ports labeled HOST 1 connect to the Routing Engine in the lower Routing
Engine slot (RE1).
4.
Plug the other end of the cable into the network device.
192 Copyright © 2015, Juniper Networks, Inc.
Figure 69: Ethernet Cable Connectors
Chapter 24: Replacing Chassis Components
HOST
0
ETHERNET
ACT 0
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
HOST
1
ETHERNET
ACT 1
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
RED ALARM
NC
C
NO
NC
C
NO
YELLOW
ALARM
Related
Documentation
•
M320 Routing Engine Interface Cable and Wire Specifications on page 115
•
M320 Routing Engine Description on page 24
•
M320 Connector Interface Panel (CIP) Description on page 13
Copyright © 2015, Juniper Networks, Inc.
193
M320 Multiservice Edge Router Hardware Guide
Replacing an M320 Console or Auxiliary Cable
1.
Removing an M320 Console or Auxiliary Cable on page 194
2.
Installing an M320 Console or Auxiliary Cable on page 195
Removing an M320 Console or Auxiliary Cable
To remove a serial cable connected to a management console or auxiliary device (see
):
1.
Turn off the power to the console or auxiliary device.
2.
Unscrew the screws that secure the cable connector to the port, using a 2.5-mm flat-blade screwdriver if necessary.
3.
Pull the cable connector straight out of the port.
4.
Disconnect the cable from the console or auxiliary device.
194 Copyright © 2015, Juniper Networks, Inc.
Chapter 24: Replacing Chassis Components
Figure 70: Routing Engine Console or Auxiliary Cable
HOST
0
ETHERNET
ACT 0
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
HOST
1
ETHERNET
ACT 1
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
RED ALARM
NC
C
NO
NC
C
NO
YELLOW
ALARM
Installing an M320 Console or Auxiliary Cable
To install a console or auxiliary cable:
1.
Turn off the power to the console or auxiliary device.
2.
Connect one end (shown in
) of the replacement serial cable into the appropriate CONSOLE or AUX port. The external device ports on the CIP. The ports labeled HOST 0 connect to the Routing Engine in the upper Routing Engine slot
(RE0), and the ports labeled HOST 1 connect to the Routing Engine in the lower Routing
Engine slot (RE1).
Copyright © 2015, Juniper Networks, Inc.
195
M320 Multiservice Edge Router Hardware Guide
3.
Using a 2.5-mm flat-blade screwdriver, tighten the screws on the connector.
4.
Attach the other end of the cable to the console or auxiliary device.
Figure 71: Routing Engine Console or Auxiliary Cable
HOST
0
ETHERNET
ACT 0
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
HOST
1
ETHERNET
ACT 1
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
196
RED ALARM
NC
C
NO
NC
C
NO
YELLOW
ALARM
5.
Connect the other end of the serial cable into the serial port on the console or auxiliary device.
Related
Documentation
•
M320 Connector Interface Panel (CIP) Description on page 13
•
M320 Routing Engine Interface Cable and Wire Specifications on page 115
Copyright © 2015, Juniper Networks, Inc.
Chapter 24: Replacing Chassis Components
•
M320 Chassis Description on page 7
Replacing an M320 Craft Interface
1.
Removing an M320 Craft Interface on page 197
2.
Installing an M320 Craft Interface on page 198
Removing an M320 Craft Interface
The craft interface is located on the front of the chassis above the FPC card cage.
The craft interface is hot-insertable and hot-removable. The craft interface weighs approximately 2 lb (0.9 kg). When you install the craft interface, allow several minutes for the display to reflect the current state of the router.
To remove the craft interface (see
):
NOTE: Removing the front upper fan tray before you remove the craft interface might make it easier to grasp the craft interface as you remove it.
For instructions on removing a front fan tray, see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Remove the upper cable guards by loosening the three captive screws on each cable guard.
3.
Completely loosen the four captive screws that attach the craft interface to the chassis.
4.
Grasp the craft interface by the left and right flanges and carefully pull it straight out of the chassis.
Figure 72: Removing the Craft Interface
Copyright © 2015, Juniper Networks, Inc.
197
M320 Multiservice Edge Router Hardware Guide
Installing an M320 Craft Interface
To install the craft interface (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasping the craft interface by the left and right flanges, press it into place.
3.
Tighten the four captive screws to attach the craft interface to the chassis.
NOTE: When you install the craft interface in an operating router, allow several minutes for the LEDs on the craft interface to reflect the current state of the router.
4.
Place one of the upper cable guards over one of the front-mounting flanges of the chassis, aligning the top of the cable guard with the top of the flange. Each of the three captive screws on the guard should be aligned with a corresponding standoff on the flange.
5.
Tighten each of the three captive screws partway on the cable guard.
6.
Tighten each of the three captive screws completely.
Figure 73: Installing the Craft Interface
Related
Documentation
•
M320 Craft Interface Description on page 15
•
M320 Craft Interface LED Display and Navigation Buttons on page 16
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
198 Copyright © 2015, Juniper Networks, Inc.
Chapter 24: Replacing Chassis Components
Replacing an M320 Fuse
WARNING: You must power off the router before removing or installing a fuse.
To replace a fuse, you remove the power supply in slot PEM0—while the router is powered on—to determine which fuse has blown. Before you remove the fuse, you must power off the router, then remove the power supply in slot PEM1 to access the fuse.
To replace a fuse (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Power off and remove the power supply in slot PEM0. For complete instructions, see
“Replacing an M320 AC Power Supply” on page 247
or
.
CAUTION: Consider the following before you remove a power supply:
• An AC-powered router can continue to provide power for all router hardware configurations with three operating power supplies. If removing the power supply from slot PEM0 leaves only two power supplies in the router, you must first ensure that the router does not consume more than 2500 W. If the router does not consume more than 2500 W, you can safely operate the router with a total of two AC power supplies. To calculate the power consumption for various hardware configurations, see
“M320 Power Requirements” on page 96 .
•
If you remove a DC power supply from slot PEM0, slot PEM2 must contain an operating DC power supply in order to keep the router operating.
For more information about power supply redundancy, see
Power Supplies Description” on page 73
and
.
3.
Determine which fuse has blown. The yellow LED under the fuse lights and the indicator bulb becomes visible through the clear cover on the fuse.
4.
Power off the router as described in
“Powering Off the M320 Router” on page 178 .
5.
Remove the power supply in slot PEM1. For complete instructions, see
M320 AC Power Supply” on page 247
or
“Replacing an M320 DC Power Supply” on page 250 .
6.
Grasp the blown fuse by the edges and rock it up and down in its slot until it disconnects. If the cover slips off the fuse, snap the cover back into place and begin again.
Copyright © 2015, Juniper Networks, Inc.
199
M320 Multiservice Edge Router Hardware Guide
NOTE: We recommend that you use an insulated fuse removal tool to remove fuses.
7.
Remove the appropriate fuse from the selection of spare fuses labeled SPARE in
Figure 74 on page 201 . (The labels shown in the figure do not appear on the actual
fuses—the clear cover on every fuse reads BUSS GMT-X—and might not match the labels on the midplane. Ignore the labels on the midplane.) Verify that the spare has the same rating and color coding as the fuse it is replacing, as specified in
Specifications” on page 99 . To see the indicator bulb and printed rating, look at the
fuse from the side.
8.
Orient the replacement fuse over the slot so that the text on the fuse cover
(BUSS GMT-X) reads from bottom to top.
9.
Press the new fuse into the slot.
10.
Reinstall the power supply into slot PEM1. For complete instructions, see
“Installing an M320 AC Power Supply” on page 248
or
“Installing an M320 DC Power Supply” on page 252 .
11.
Power on the router as described in
“Powering On the M320 Router” on page 176 .
12.
Verify that the yellow LED under the replacement fuse is no longer lit.
13.
Reinstall the power supply into slot PEM0 and power it on. For complete instructions, see
“Installing an M320 AC Power Supply” on page 248
or
14.
Order new fuses from an electrical supply house to replace the spare fuses. The Cooper
Bussman product number for each fuse is GMT-X, where X is the amperage rating. For example, product number GMT-15 is a 15-A fuse, required for an FPC.
200 Copyright © 2015, Juniper Networks, Inc.
Figure 74: Fuses in the Midplane
Chapter 24: Replacing Chassis Components
Related
Documentation
•
•
Troubleshooting the M320 Fuses on page 290
•
M320 Power System Description on page 73
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Copyright © 2015, Juniper Networks, Inc.
201
M320 Multiservice Edge Router Hardware Guide
202 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 25
Replacing Cooling System Components
•
Replacing an M320 Air Filter on page 203
•
Replacing an M320 Fan Tray on page 208
Replacing an M320 Air Filter
•
Removing an M320 Front Air Filter on page 203
•
Installing an M320 Front Air Filter on page 204
•
Removing an M320 Rear Air Filter on page 205
•
Installing an M320 Rear Air Filter on page 207
Removing an M320 Front Air Filter
The front air filter, located below the FPC card cage in the front of the chassis, and installs horizontally. The front air filter weighs approximately 1 lb (0.5 kg).The air filters are hot-insertable and hot-removable.
To remove the front air filter (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Unwrap any PIC cables from the spools on the cable management system, and remove the cables from the tray. Arrange the cables so that they do not block the front of the cable management system and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from the connector.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
3.
Simultaneously pull the two releases on the cable management system. Lift it up and outward to lock it in place to access the air filter.
4.
Loosen the captive screws on the corners of the air filter faceplate.
5.
Grasp the handles and pull the air filter straight out of the chassis.
6.
Remove the filter element from the air filter frame (see
).
Copyright © 2015, Juniper Networks, Inc.
203
M320 Multiservice Edge Router Hardware Guide
Figure 75: Removing the Front Air Filter
Figure 76: Replacing the Front Filter Element
Installing an M320 Front Air Filter
To install the front air filter (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Insert the filter element into the air filter frame.
3.
Grasp the air filter by the handles on its faceplate, and slide it straight into the chassis.
4.
Tighten the captive screws on the corners of the faceplate.
5.
Unlock the cable management system, and lower it to the fully lowered position.
6.
Rearrange the PIC cables in the cable management system.
204 Copyright © 2015, Juniper Networks, Inc.
Chapter 25: Replacing Cooling System Components
Figure 77: Installing the Front Air Filter
Removing an M320 Rear Air Filter
The rear air filter is located at the left rear edge of the chassis. The rear air filter weighs less than 1 lb (0.5 kg).
To remove the rear air filter:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws at the top, center, and bottom of the air filter, using a
Phillips (+) screwdriver, number 2.
3.
Grasp the air filter cover by the captive screws, and pull firmly to remove the cover and honeycomb assembly from the chassis (see
4.
Press the filter element inward until it clears the hooks at the top and bottom of the air filter slot, then push it to the left to unseat it.
5.
Move the tabs on the filter element to a horizontal position.
6.
Grasp the tabs on the filter element and carefully pull it straight out from the chassis
(see
Copyright © 2015, Juniper Networks, Inc.
205
M320 Multiservice Edge Router Hardware Guide
Figure 78: Removing the Rear Air Filter
206 Copyright © 2015, Juniper Networks, Inc.
Chapter 25: Replacing Cooling System Components
Figure 79: Removing the Rear Air Filter Element
Installing an M320 Rear Air Filter
To install the rear air filter (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Align the filter with the right side of the air filter slot and carefully push the filter all the way into the slot. The top and bottom air filter guides direct the filter to the left as it is pushed into the slot.
3.
Holding the filter all the way in, push it to the right side of the slot until it is held in place behind the hooks.
4.
Place the right edge of the honeycomb against the flange of the air filter slot.
5.
Line up the holes at the top, center, and bottom of the honeycomb with the pins in the slot and press the honeycomb into place.
6.
Replace the air filter cover.
7.
Firmly tighten the captive screws at the top, center, and bottom of the filter cover to secure it to the chassis, using a Phillips (+) screwdriver, number 2.
Copyright © 2015, Juniper Networks, Inc.
207
M320 Multiservice Edge Router Hardware Guide
Figure 80: Installing the Rear Air Filter
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
M320 Cooling System Description on page 21
•
Maintaining the M320 Fan Trays on page 268
•
Maintaining the M320 Air Filters on page 267
•
Troubleshooting the M320 Cooling System on page 287
Replacing an M320 Fan Tray
•
Removing an M320 Front Fan Tray on page 208
•
Installing an M320 Front Fan Tray on page 210
•
Removing an M320 Rear Fan Tray on page 210
•
Installing an M320 Rear Fan Tray on page 211
Removing an M320 Front Fan Tray
The router has two front fan trays. The front fan trays install horizontally in the front of the chassis. Each front fan tray contains four fans. The two front fan trays are interchangeable, but the rear fan tray is not interchangeable with the front fan trays. The fan trays are hot-insertable and hot-removable.
The upper front fan tray is located above the FPC card cage, and the lower front fan tray is located below the front air filter. Each fan tray weighs about 11 lb (5.1 kg).
208 Copyright © 2015, Juniper Networks, Inc.
Chapter 25: Replacing Cooling System Components
To remove a front fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
If you are removing the lower fan tray, perform the following steps: a.
Unwrap any PIC cables from the spools on the cable management system and remove the cables from the tray. Arrange the cables so that they do not block the front of the cable management system and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from the connector.
CAUTION: Do not let fiber-optic cable hang free from the connector.
Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
b.
Simultaneously pull the two releases labeled PULL on the cable management system. Lift it up and outward to lock it in place to access the lower fan tray.
3.
Loosen the captive screw on each side of the fan tray faceplate.
4.
Grasp the handles and pull the fan tray until it stops.
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
5.
Press the tabs on both sides of the fan tray and pull the fan tray halfway out of the chassis.
6.
When the fans stop spinning, place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
Figure 81: Removing a Front Fan Tray
Copyright © 2015, Juniper Networks, Inc.
209
M320 Multiservice Edge Router Hardware Guide
Installing an M320 Front Fan Tray
To install a front fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles and insert it straight into the chassis.
3.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
4.
If you are installing the lower fan tray, follow these steps: a.
Unlock the cable management system and lower it to the fully lowered position.
b.
Rearrange the PIC cables in the cable management system. For more information about proper cable arrangement, see
“Maintaining M320 PICs and PIC Cables” on page 276 .
Figure 82: Installing a Front Fan Tray
Removing an M320 Rear Fan Tray
The rear fan tray is mounted vertically on the right side of the rear of the chassis. The rear fan tray contains seven fans. The fan tray weighs about 8.4 lb (3.8 kg).
CAUTION: To maintain proper cooling, do not operate the router with the rear fan tray removed for more than 1 minute.
To remove the rear fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws on the top and bottom of the fan tray faceplate, using a
Phillips (+) screwdriver, number 2.
3.
Grasp the handle and pull the fan tray halfway out of the chassis.
210 Copyright © 2015, Juniper Networks, Inc.
Chapter 25: Replacing Cooling System Components
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
4.
When the fans stop spinning, place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
Figure 83: Removing the Rear Fan Tray
Installing an M320 Rear Fan Tray
To install a replacement rear fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the handle with one hand and place the other hand under the fan tray. Insert the fan tray straight into the chassis.
Copyright © 2015, Juniper Networks, Inc.
211
M320 Multiservice Edge Router Hardware Guide
3.
Tighten the captive screws on the fan tray faceplate to secure it in the chassis, using a Phillips (+) screwdriver, number 2.
Figure 84: Installing a Rear Fan Tray
212
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
M320 Cooling System Description on page 21
•
Maintaining the M320 Fan Trays on page 268
•
Maintaining the M320 Air Filters on page 267
•
Troubleshooting the M320 Cooling System on page 287
Copyright © 2015, Juniper Networks, Inc.
CHAPTER 26
Replacing Host Subsystem Components
•
Taking the M320 Host Subsystem Offline on page 213
•
Replacing an M320 Routing Engine on page 216
•
Replacing a Solid-State Disk on an M320 RE-A-1800 Routing Engine on page 218
•
Inserting or Removing a PC Card from an M320 Routing Engine on page 219
•
Replacing a DIMM Module in an M320 Routing Engine on page 221
•
Replacing an M320 Control Board on page 223
Taking the M320 Host Subsystem Offline
The host subsystem is taken offline and brought online as a unit. Before you replace a
CB or a Routing Engine, you must take the host subsystem offline.
Normally, if two host subsystems are installed in the router, RE0 functions as the master and RE1 functions as the backup. You can remove the backup host subsystem (or either of its components) without interrupting the functioning of the router. If you take the master host subsystem offline, the backup host subsystem becomes the master (the router might reboot, depending on your configuration). If the router has only one host subsystem, taking the host subsystem offline causes the router to shut down.
explains the effect of taking the host subsystem offline.
Table 77: Effect of Taking the Host Subsystem Offline
Type of Host Subsystem Effect of Taking the Host Subsystem Offline
The router shuts down.
Nonredundant host subsystem
Backup host subsystem The functioning of the router is not interrupted. The backup host subsystem is hot-removable and hot-insertable.
Copyright © 2015, Juniper Networks, Inc.
213
M320 Multiservice Edge Router Hardware Guide
Table 77: Effect of Taking the Host Subsystem Offline (continued)
Type of Host Subsystem Effect of Taking the Host Subsystem Offline
Master host subsystem The backup host subsystem becomes the master. The backup Routing Engine assumes Routing
Engine functions. The master host subsystem is hot-pluggable. Removal or failure of the master
Routing Engine affects forwarding and routing based on the high availability configuration:
• Dual Routing Engines without any high availability features enabled—Traffic is interrupted while the Packet Forwarding Engine is reinitialized. All kernel and forwarding processes are restarted. When the switchover to the new master Routing Engine is complete, routing convergence takes place and traffic is resumed.
•
•
Graceful Routing Engine switchover (GRES) is enabled—Graceful Routing Engine switchover preserves interface and kernel information. Traffic is not interrupted. However, graceful Routing
Engine switchover does not preserve the control plane. Neighboring routers detect that the router has restarted and react to the event in a manner prescribed by individual routing protocol specifications. To preserve routing without interruption during a switchover, graceful Routing
Engine switchover must be combined with nonstop active routing.
Nonstop active routing is enabled (graceful Routing Engine switchover must be configured for nonstop active routing to be enabled)—Nonstop active routing supports Routing Engine switchover without alerting peer nodes that a change has occurred. Nonstop active routing uses the same infrastructure as graceful Routing Engine switchover to preserve interface and kernel information. However, nonstop active routing also preserves routing information and protocol sessions by running the routing protocol process (rpd) on both Routing Engines. In addition, nonstop active routing preserves TCP connections maintained in the kernel.
• Graceful restart is configured—Graceful restart provides extensions to routing protocols so that neighboring helper routers restore routing information to a restarting router. These extensions signal neighboring routers about the graceful restart and prevent the neighbors from reacting to the router restart and from propagating the change in state to the network during the graceful restart period. Neighbors provide the routing information that enables the restarting router to stop and restart routing protocols without causing network reconvergence.
Neighbors are required to support graceful restart. The routing protocol process (rpd) restarts.
A graceful restart interval is required. For certain protocols, a significant change in the network can cause graceful restart to stop.
NOTE: Router performance might change if the backup Routing Engine's configuration differs from the former master's configuration. For the most predictable performance, configure the two Routing Engines identically, except for parameters unique to each Routing Engine.
NOTE: For information about configuring graceful Routing Engine switchover, graceful restart, and nonstop active routing, see the Junos OS High Availability
Library for Routing Devices.
214 Copyright © 2015, Juniper Networks, Inc.
Chapter 26: Replacing Host Subsystem Components
NOTE: The first supported release for graceful Routing Engine switchover and nonstop active routing on the M320 router is Junos OS Release 6.2 and
Junos OS Release 8.4, respectively. However, we recommend Junos OS
Release 7.0 or later for graceful Routing Engine switchover. Graceful restart software requirements are dependent on the routing protocols configured on the router. For the minimum software requirements for graceful restart, see the Junos OS High Availability Library for Routing Devices.
To take a host subsystem offline:
1.
Determine whether the host subsystem is functioning as the master or as the backup, using one of the two following methods:
• Check the Routing Engine LEDs on the craft interface. If the green MASTER LED is lit, the corresponding host subsystem is functioning as the master.
• Issue the following CLI command. The master Routing Engine is designated Master in the Current state field: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
...
2.
If the host subsystem is functioning as the master, switch it to backup using the CLI command: user@host> request chassis routing-engine master switch
NOTE: Router performance might change if the standby Routing Engine’s configuration differs from the former master's configuration. For the most predictable performance, configure the two Routing Engines identically, except for parameters unique to a Routing Engine, such as the hostname defined at the [edit system] hierarchy level and the management interface
(fxp0 or equivalent) defined at the [edit interfaces] hierarchy level.
To configure Routing Engine-specific parameters and still use the same configuration on both Routing Engines, include the appropriate configuration statements under the re0 and re1 statements at the [edit groups] hierarchy level and use the apply-groups statement. For instructions, see the Junos OS Administration Library for Routing Devices.
3.
On the console or other management device connected to the Routing Engine for the affected host subsystem, enter CLI operational mode and issue the following command. The command shuts down the Routing Engine cleanly, so its state information is preserved: user@host> request system halt
Wait until a message appears on the console confirming that the operating system has halted.
Copyright © 2015, Juniper Networks, Inc.
215
M320 Multiservice Edge Router Hardware Guide
For more information about the command, see the
CLI Explorer
.
NOTE: The SIB might continue forwarding traffic for approximately five minutes after the request system halt command has been issued.
4.
On the console or other management device connected to the other Routing Engine, enter CLI operational mode and issue the following command.
5.
user@host>> request chassis cb offline slot n , where n is 0 or 1 for the slot number of the affected host subsystem.
Verify that the control board is offline: user@host> show chassis environment cb
Related
Documentation
•
M320 Host Subsystem Description on page 23
•
Maintaining the M320 Host Subsystem on page 269
•
M320 Chassis Description on page 7
Replacing an M320 Routing Engine
1.
Removing an M320 Routing Engine on page 216
2.
Installing an M320 Routing Engine on page 217
Removing an M320 Routing Engine
The router can have one or two Routing Engines. They are located in the upper rear of the chassis in the slots marked RE0 and RE1. Each Routing Engine weighs approximately
2.4 lb (1.1 kg).
CAUTION: Before you replace a Routing Engine, you must take the host subsystem offline. If there is only one host subsystem, taking the host subsystem offline shuts down the router. See
Subsystem Offline” on page 213 .
To remove a Routing Engine (see
1.
Take the host subsystem offline as described in
“Taking the M320 Host Subsystem
2.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
If applicable, loosen the screws on the extractor handles at either end of the Routing
Engine faceplate, using a Phillips screwdriver.
5.
Press the red tabs on the ejector handles on both sides of the Routing Engine faceplate.
6.
Flip the ejector handles outward to unseat the Routing Engine.
216 Copyright © 2015, Juniper Networks, Inc.
Chapter 26: Replacing Host Subsystem Components
7.
Grasp the Routing Engine by the ejector handles, and slide it about halfway out of the chassis.
8.
Place one of your hands underneath the Routing Engine to support it, and slide it completely out of the chassis.
9.
Place the Routing Engine on the antistatic mat.
10.
If you are not replacing the Routing Engine now, install a blank panel over the empty slot.
Figure 85: Removing a Routing Engine
Installing an M320 Routing Engine
To install a Routing Engine (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Ensure that the ejector handles are not in the locked position. If necessary, press the red tabs and flip the ejector handles outward.
3.
Place one hand underneath the Routing Engine to support it. With the other hand, grasp one of the ejector handles on the faceplate.
4.
Carefully align the sides of the Routing Engine with the guides inside the chassis.
5.
Slide the Routing Engine into the chassis until you feel resistance, then press the
Routing Engine's faceplate until it engages the midplane connectors.
6.
Press both the ejector handles inward to seat the Routing Engine.
The Routing Engine might require several minutes to boot.
7.
If applicable, tighten the screws on the extractor handles, using a Phillips screwdriver.
Be sure to tighten the screws enough to seat the Routing Engine properly.
8.
After the Routing Engine boots, verify that it is installed correctly by checking the RE0 and RE1 LEDs on the craft interface. If the router is operational and the Routing Engine is functioning properly, the green OK LED lights steadily. If the red FAIL LED lights steadily instead, remove and install the Routing Engine again. If the red FAIL LED still lights steadily, the Routing Engine is not functioning properly. Contact your customer support representative.
Copyright © 2015, Juniper Networks, Inc.
217
M320 Multiservice Edge Router Hardware Guide
To check the status of the Routing Engine, use the CLI command: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
...
For more information about using the CLI, see the Junos OS manuals.
Figure 86: Installing a Routing Engine
Related
Documentation
•
M320 Routing Engine Description on page 24
•
Maintaining the M320 Host Subsystem on page 269
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
Synchronizing Routing Engines
Replacing a Solid-State Disk on an M320 RE-A-1800 Routing Engine
Each RE-1800 Routing Engine supports two solid-state disks (SSD) specified by Juniper
Networks. The RE-1800 ships with one SSD installed.
shows the arrangement of SSD slots on a RE-1800 Routing Engine.
Figure 87: RE-A-1800 Routing Engine SSD Slots
Online/Offline button
SSD slot 1
SSD slot 2
Extractor clip
USB port
Reset button
Online
LED
Storage
LED
Extractor clip
218 Copyright © 2015, Juniper Networks, Inc.
Chapter 26: Replacing Host Subsystem Components
The following SSD has been verified to work in the RE-1800 Routing Engines:
•
SSD SLC 32 GB
1.
Removing an Solid-State Disk From an M320 RE-A-1800 Routing Engine on page 219
2.
Installing an Solid-State Disk on an M320 RE-A-1800 Routing Engine on page 219
Removing an Solid-State Disk From an M320 RE-A-1800 Routing Engine
To remove an SSD:
1.
Disable and deactivate the SSD.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an ESD point on the chassis.
3.
Unfasten the thumbscrew that secures the access door in front of the SSD slots, and open the door.
4.
Slide the lock on the ejector to the unlocked position.
5.
Carefully slide the SSD out of the slot.
Installing an Solid-State Disk on an M320 RE-A-1800 Routing Engine
To install an SSD:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an ESD point on the chassis.
2.
Carefully align the sides of the SSD with the guides in the slot.
3.
Slide the SSD into the slot until you feel resistance, carefully ensuring that it is correctly aligned.
4.
Close the access door and tighten the thumbscrew to secure the door.
5.
Mount the new SSD.
Related
Documentation
•
M320 RE-A-1800 Routing Engine Description on page 28
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
Returning a Hardware Component to Juniper Networks, Inc. on page 307
Inserting or Removing a PC Card from an M320 Routing Engine
The slots labeled PC CARD on the Routing Engine faceplate accept a Type I PC Card, as defined in the PC Card Standard published by the Personal Computer Memory Card
International Association (PCMCIA). The router is shipped with a PC Card that contains the Junos OS. The PC Card can be used to copy Junos OS from the PC Card onto the
Routing Engine. You can also copy Junos OS from the Routing Engine onto a PC Card, for example, to create a backup copy of upgrade software that you have obtained from
Juniper Networks. Instructions for copying software to a PC Card are available at the
Copyright © 2015, Juniper Networks, Inc.
219
M320 Multiservice Edge Router Hardware Guide
Juniper Networks Support Web site ( http://www.juniper.net/support/
). After logging in, navigate to the Customer Support Center, then to the download page for Junos OS.
NOTE: The software on a PC Card is loaded only onto the Routing Engine into which the PC Card is inserted. It is not automatically copied to the other
Routing Engine.
•
Inserting a PC Card into an M320 Routing Engine on page 220
•
Removing an M320 PC Card on page 221
Inserting a PC Card into an M320 Routing Engine
To insert a PC card (see
):
1.
Insert the PC card into either PC card slot on the Routing Engine, with the Juniper
Networks logo facing downward.
CAUTION: Be sure to insert the PC card with the label facing downward.
Inserting the PC card incorrectly might damage the Routing Engine.
CAUTION: Do not install more than one PC card in the Routing Engine.
2.
Press the card firmly all the way into the slot.
3.
To verify the PC card is installed correctly, check that the corresponding slot LED
(labeled 0 or 1 SLOT) is lit.
Figure 88: Installing a PC Card
220 Copyright © 2015, Juniper Networks, Inc.
Chapter 26: Replacing Host Subsystem Components
Removing an M320 PC Card
The PC card is inserted into one of the two slots—0 or 1—labeled PC CARD on the Routing
Engine. To remove the PC card (see
1.
Have ready an antistatic mat, placed on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
On the Routing Engine faceplate, press the eject button on the right side of the PC card slot once to release the button. Press again to release the PC card.
4.
The PC card pops partially out of the slot. Grasp the card and pull it completely out of the slot.
5.
Place the PC card on the antistatic mat.
Figure 89: Removing a PC Card
Related
Documentation
•
M320 Host Subsystem Description on page 23
•
M320 Routing Engine Description on page 24
•
Maintaining the M320 Host Subsystem on page 269
•
M320 Chassis Description on page 7
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Replacing a DIMM Module in an M320 Routing Engine
1.
Removing an M320 DIMM Module on page 222
2.
Installing an M320 DIMM Module on page 222
Copyright © 2015, Juniper Networks, Inc.
221
M320 Multiservice Edge Router Hardware Guide
Removing an M320 DIMM Module
CAUTION: Before you remove a DIMM module from a Routing Engine, you must take the host subsystem offline. If there is only one host subsystem, taking the host subsystem offline shuts down the router. See
M320 Host Subsystem Offline” on page 213 .
The DIMM modules are located on the top of the Routing Engine. To remove a DIMM module:
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Remove the Routing Engine.
See
“Removing an M320 Routing Engine” on page 216 .
4.
Depending on which Routing Engine you are using, there are two different procedures for ejecting the DIMMs:
•
For Routing Engines with an ejector on one side of the DIMM, press the plastic ejector of the DIMM module. The edge of the module raises upward.
• For Routing Engines with ejectors on each side of the DIMM, press the plastic ejectors on both sides of the DIMM module.
5.
Grasp the DIMM module, being careful not to touch any electrical components on the module, and firmly pull it out of the slot on the Routing Engine.
6.
Place the DIMM module on the antistatic mat or in the electrostatic bag.
7.
Push the plastic ejectors to close the empty DIMM module slot.
Installing an M320 DIMM Module
NOTE: When installing DIMMs on an RE-1800, make sure that all DIMMs are manufactured by the same vendor. If necessary, replace an existing DIMM with a new DIMM.
To insert a DIMM module into the Routing Engine:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Remove the DIMM module from its electrostatic bag.
3.
To open the empty DIMM slot, press the plastic ejectors open.
4.
Grasp the DIMM module by the edges, being careful not to touch any electrical components.
222 Copyright © 2015, Juniper Networks, Inc.
Chapter 26: Replacing Host Subsystem Components
5.
Pressing firmly on both ends, push the module into the slot until the ejectors return completely to the closed position.
6.
Install the Routing Engine. See
“Installing an M320 Routing Engine” on page 217 .
7.
You can view the SDRAM configuration and verify the DIMM was installed correctly by issuing the show chassis routing-engine command.
Figure 90: Installing the DIMM Module
Related
Documentation
•
M320 Routing Engine Description on page 24
•
Replacing an M320 Routing Engine on page 216
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Replacing an M320 Control Board
1.
Removing an M320 Control Board on page 223
2.
Installing an M320 Control Board on page 225
Removing an M320 Control Board
The router can have one or two CBs. They are located in the upper rear of the chassis in the slots marked CB0 and CB1. Each weighs approximately 3.4 lb (1.5 kg).
Copyright © 2015, Juniper Networks, Inc.
223
M320 Multiservice Edge Router Hardware Guide
To remove a CB, (see
):
1.
Take the host subsystem offline.
CAUTION:
Before you replace a CB, you must take the host subsytem offline:
• Before taking the host subystem offline, switch the Routing Engine to be the backup if the CB to be replaced is associated with the Routing
Engine currently functioning as the master Routing engine.
•
Taking the host subsystem offline includes both the Routing Engine and
CB. If there is only one host subsystem, taking the host subsystem offline shuts down the router.
See
“Taking the M320 Host Subsystem Offline” on page 213
.
2.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
If applicable, disconnect the cables plugged into the ports labeled EXTERNAL CLOCK
INPUTS
.
5.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on both sides of the CB faceplate.
6.
Flip the ejector handles outward to unseat the CB.
7.
Grasp the ejector handles, and slide the CB about halfway out of the chassis.
8.
Place one hand underneath the CB to support it, and slide it completely out of the chassis.
9.
Place the CB on the antistatic mat.
10.
If you are not replacing the CB now, install a blank panel over the empty slot.
Figure 91: Removing a CB
224 Copyright © 2015, Juniper Networks, Inc.
Chapter 26: Replacing Host Subsystem Components
Installing an M320 Control Board
To install a CB (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Carefully align the sides of the CB with the guides inside the chassis.
3.
Slide the CB into the chassis, carefully ensuring that it is correctly aligned.
4.
Grasp both ejector handles, and press them inward to seat the CB.
5.
Tighten the captive screws on the ejector handles, using a Phillips (+) screwdriver, number 2.
6.
If applicable, reconnect the cable previously plugged into the port or ports.
7.
If power is applied to the Routing Engine and its corresponding CB is functioning normally, the CB comes online automatically. To verify that the CB is functioning normally, check the LEDs on its faceplate. The green OK LED should light steadily a few minutes after the CB is installed. If the FAIL LED is lit steadily, remove and install the CB again. If the FAIL LED still lights steadily, the CB is not functioning properly.
Contact your customer support representative.
To check the status of the CB, use the CLI command:
Figure 92: Installing a CB
user@host> show chassis environment cb
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
M320 Host Subsystem Description on page 23
•
Maintaining the M320 Host Subsystem on page 269
•
Taking the M320 Host Subsystem Offline on page 213
Copyright © 2015, Juniper Networks, Inc.
225
M320 Multiservice Edge Router Hardware Guide
•
M320 Control Board (CB) Description on page 45
226 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 27
Replacing Line Card Components
•
Replacing an M320 FPC on page 227
•
Replacing an M320 PIC on page 233
•
Replacing M320 PIC Cables on page 237
•
Replacing an M320 SFP on page 240
•
Replacing an M320 XENPAK Module on page 243
Replacing an M320 FPC
1.
Removing an M320 FPC on page 227
2.
Installing an M320 FPC on page 230
Removing an M320 FPC
When you remove an FPC, the router continues to function, although the PIC interfaces installed on the FPC being removed no longer function.
The router holds up to eight FPCs, which are installed vertically in the front of the router.
The FPCs are hot-insertable and hot-removable. An empty FPC1 or FPC2 weighs
15 lb (6.8 kg), and an empty FPC3 weighs 16 lb (7.3 kg). A fully configured FPC can weigh up to 29 lb (13.2 kg)
To remove an FPC (see
):
1.
Have ready a replacement FPC or FPC blank panel and an antistatic mat for the FPC.
Also have ready rubber safety caps for each PIC using an optical interface on the FPC that you are removing.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Label the cables connected to each PIC on the FPC so that you can later reconnect the cables to the correct PICs.
4.
Use one of the following methods to take the FPC offline:
•
Press and hold the FPC online/offline button. The green OK LED next to the button begins to blink. Hold the button down until the LED goes out. The LEDs and online/offline button for each FPC are located directly above it on the craft interface.
Copyright © 2015, Juniper Networks, Inc.
227
M320 Multiservice Edge Router Hardware Guide
•
Issue the following CLI command: user@host> request chassis fpc slot slot-number offline
For more information about the command, see the
CLI Explorer
.
5.
Disconnect the cables from the PICs installed in the FPC. If a PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap. Arrange the disconnected cables in the cable management system, to prevent the cables from developing stress points.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
6.
Simultaneously turn both the ejector handles counterclockwise to unseat the FPC.
7.
Grasp the handles and slide the FPC straight out of the card cage halfway.
8.
Place one hand around the front of the FPC (the PIC housing) and the other hand under it to support it. Slide the FPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: The weight of the FPC is concentrated in the back end. Be prepared to accept the full weight—up to 29 lb (13.2 kg)—as you slide the
FPC out of the chassis.
When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
Do not stack FPCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
9.
If necessary, remove each installed PIC from the FPC. For information on removing a
PIC, see
“Removing an M320 PIC” on page 233
.
228 Copyright © 2015, Juniper Networks, Inc.
Chapter 27: Replacing Line Card Components
10.
After you remove each PIC, immediately place it on an antistatic mat or in an electrostatic bag.
11.
If you are not reinstalling a FPC into the emptied FPC slot within a short time, install a blank FPC panel over the slot to maintain proper airflow in the FPC card cage.
CAUTION: After removing an FPC from the chassis, wait at least 30 seconds before reinserting it, removing an FPC from a different slot, or inserting an FPC into a different slot.
Figure 93: Removing an FPC
Copyright © 2015, Juniper Networks, Inc.
229
M320 Multiservice Edge Router Hardware Guide
Installing an M320 FPC
To install an FPC (see
and
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Place the FPC on an antistatic mat.
3.
Take each PIC to be installed in the replacement FPC out of its electrostatic bag and identify the slot on the FPC where it will be connected.
4.
Verify that each fiber-optic PIC has a rubber safety cap covering the PIC transceiver.
If it does not, cover the transceiver with a safety cap.
5.
Install each PIC into the appropriate slot on the FPC. For information on installing a
PIC, see
“Installing an M320 PIC” on page 235
.
6.
Locate the slot in the FPC card cage in which you plan to install the FPC.
7.
Lift the FPC into place and carefully align first the bottom, then the top of the FPC with the guides inside the card cage. Be sure the FPC is right-side up, with the components on the right of the FPC.
CAUTION: When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
8.
Slide the FPC all the way into the card cage until you feel resistance.
9.
Starting with the ejector handles on the FPC faceplate nearly horizontal, simultaneously turn both ejector handles clockwise to seat the FPC.
10.
If any of the PICs on the FPC connect to fiber-optic cable, remove the rubber safety cap from each transceiver and cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
11.
Insert the appropriate cable into the cable connector ports on each PIC on the FPC.
Secure the cables so that they are not supporting their own weight. Place excess cable out of the way in a neatly coiled loop, using the cable management system. Placing fasteners on a loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
230 Copyright © 2015, Juniper Networks, Inc.
Chapter 27: Replacing Line Card Components
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
12.
Use one of the following methods to bring the FPC online:
• Press and hold the FPC online/offline button until the green OK LED next to the button lights steadily, in about 5 seconds. The LEDs and online/offline button for each FPC are located directly above it on the craft interface.
•
Issue the following CLI command: user@host> request chassis fpc slot slot-number online
For more information about the command, see the CLI Explorer .
CAUTION: After the OK LED lights steadily, wait at least 30 seconds before removing the FPC again, removing an FPC from a different slot, or inserting an FPC in a different slot.
You can also verify correct FPC and PIC functioning by issuing the show chassis fpc and show chassis fpc pic-status commands, as described in
“Maintaining M320 FPCs” on page 270
and
“Maintaining M320 PICs and PIC Cables” on page 276 .
Copyright © 2015, Juniper Networks, Inc.
231
M320 Multiservice Edge Router Hardware Guide
Figure 94: Installing an FPC
232 Copyright © 2015, Juniper Networks, Inc.
Chapter 27: Replacing Line Card Components
Figure 95: Connecting Fiber-Optic Cable to a PIC
Related
Documentation
•
M320 FPCs Supported on page 53
•
M320 Flexible PIC Concentrator (FPC) Description on page 49
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Replacing an M320 PIC
1.
Removing an M320 PIC on page 233
2.
Installing an M320 PIC on page 235
Removing an M320 PIC
PICs are hot-insertable and hot-removable. When you remove a PIC, the router continues to function, although the PIC interfaces being removed no longer function.
The PICs are located in the FPCs installed in the front of the router. A PIC weighs less than 2 lb (0.9 kg).
To remove a PIC (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the
PIC. If the PIC connects to fiber-optic cable, have ready a rubber safety cap for each transceiver and cable.
2.
Attach an electrostatic discharge ESD grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Use one of the following methods to take the PIC offline:
•
Press and hold the online/offline button until the PIC LED goes out (about 5 seconds).
Copyright © 2015, Juniper Networks, Inc.
233
M320 Multiservice Edge Router Hardware Guide
For a PIC installed in a Type 1 FPC, use a tool—such as a flat-blade screwdriver—to press the button slightly beneath the faceplate of the PIC. For a PIC installed in a
Type 2 FPC or Type 3 FPC, use a narrow-ended tool that fits inside the opening that leads to the button.
•
Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline
For more information about the command, see request chassis pic.
4.
Label the cables connected to the PIC so that you can later reconnect each cable to the correct PIC.
5.
Disconnect the cables from the PIC. If the PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
6.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
7.
Unseat the PIC:
• Type 1 or Type 2 PIC—Loosen the captive screws at the top and bottom of the PIC faceplate.
•
Type 3 PIC—Loosen the captive screw at the bottom of the PIC faceplate, then twist the ejector handle at the top of the faceplate and counterclockwise to unseat the
PIC.
•
Type 4 PIC—Twist the ejector handle at the bottom of the PIC faceplate, then twist the ejector handle at the top of the faceplate and counterclockwise to unseat the
PIC.
234 Copyright © 2015, Juniper Networks, Inc.
Chapter 27: Replacing Line Card Components
8.
Slide the PIC out of the FPC card carrier, and place it in the electrostatic bag or on the antistatic mat.
9.
If you are not reinstalling a PIC into the emptied PIC slot within a short time, install a blank PIC panel over the slot to maintain proper airflow in the FPC card cage.
Figure 96: Removing a PIC
Installing an M320 PIC
To install a PIC (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
If the PIC uses fiber-optic cable, verify that there is a rubber safety cap over each transceiver on the faceplate. Install a cap if necessary.
3.
Align the notches in the connector at the rear of the PIC with the notches in the PIC slot in the FPC and then slide the PIC in until it lodges firmly in the FPC.
CAUTION: Slide the PIC straight into the slot to avoid damaging the components on the bottom of the PIC.
Copyright © 2015, Juniper Networks, Inc.
235
M320 Multiservice Edge Router Hardware Guide
236
4.
Secure the PIC to the FPC faceplate:
• Type 1 or Type 2 PICs—Tighten the captive screws at the top and bottom of the faceplate.
•
Type 3 PICs—Turn the ejector handle at the top of the PIC faceplate clockwise, then tighten the captive screw at the bottom of the faceplate.
• Type 4 PIC—Twist the ejector handle at the bottom of the PIC faceplate, then twist the ejector handle at the top of the faceplate and counterclockwise to unseat the
PIC.
5.
If the PIC uses fiber-optic cable, remove the rubber safety cap from each transceiver and the end of each cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
6.
Insert the appropriate cables into the cable connectors on the PIC.
7.
Arrange each cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
8.
Use one of the following methods to bring the PIC online:
• Press the PIC offline/online button until the PIC LED lights green. For a PIC installed in a Type 1 FPC, use a tool—such as a flat-blade screwdriver—to press the button slightly beneath the faceplate of the PIC. For a PIC installed in a Type 2 FPC or Type
3 FPC, use a narrow-ended tool that fits inside the opening that leads to the button.
• Issue the following CLI command:
Copyright © 2015, Juniper Networks, Inc.
Chapter 27: Replacing Line Card Components user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see request chassis pic.
The normal functioning status LED confirms that the PIC is online. You can also verify correct PIC functioning by issuing the show chassis fpc pic-status command.
Figure 97: Installing a PIC
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
M320 PIC Description on page 54
•
Maintaining M320 PICs and PIC Cables on page 276
•
Troubleshooting the M320 PICs on page 291
Replacing M320 PIC Cables
1.
Removing an M320 PIC Cable on page 238
2.
Installing an M320 PIC Cable on page 238
Copyright © 2015, Juniper Networks, Inc.
237
M320 Multiservice Edge Router Hardware Guide
Removing an M320 PIC Cable
Removing and installing PIC cables do not affect router function, except that a PIC does not receive or transmit data while its cable is disconnected.
To remove a PIC cable:
1.
If the PIC connects to fiber-optic cable, have ready a rubber safety cap for each cable and transceiver.
2.
If removing all cables connected to the PIC, use one of the following methods to take the PIC offline:
•
Press its online/offline button. For a PIC installed in an FPC1, use a tool—such as a flat-blade screwdriver—to press the button slightly beneath the faceplate of the
PIC. For a PIC installed in an FPC2 or FPC3, use a narrow-ended tool that fits inside the opening that leads to the button. Press and hold the button until the PIC LED goes out (about 5 seconds).
•
Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline
For more information about the command, see the
CLI Explorer
.
3.
Unplug the cable from the cable connector port. If the PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
4.
Remove the cable from the cable management system and detach it from the destination port.
Installing an M320 PIC Cable
To install a PIC cable (see
):
1.
Have ready a length of the type of cable used by the PIC. For cable specifications, see the M320 Multiservice Edge Router Interface Module Reference.
2.
If the PIC cable connector port is covered by a rubber safety plug, remove the plug.
238 Copyright © 2015, Juniper Networks, Inc.
Chapter 27: Replacing Line Card Components
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
3.
Insert the cable connector into the cable connector port on the PIC faceplate.
4.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
5.
After you have draped the PIC cables, you can optionally install the cable cover (the cable cover prevents the PIC and CIP cables from being disturbed or snagged). To install the cable cover, insert the upper tabs of the cover into the slots of the upper cable guards, then insert the lower tabs of the cover into the slots of the lower cable guards (see
“Connecting PIC Cables to the M320 Router” on page 169
).
6.
Insert the other end of the cable into the destination port.
7.
Repeat the previous steps for any additional cables.
8.
If the PIC is offline (its failure indicator LED is lit), use one of the following methods to bring the PIC online:
•
Press the PIC offline/online button until the PIC LED lights green. For a PIC installed in an FPC1, use a tool—such as a flat-blade screwdriver—to press the button slightly beneath the faceplate of the PIC. For a PIC installed in an FPC2 or FPC3, use a narrow-ended tool that fits inside the opening that leads to the button.
•
Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer .
Copyright © 2015, Juniper Networks, Inc.
239
M320 Multiservice Edge Router Hardware Guide
The normal functioning indicator LED confirms that the PIC is online. You can also verify correct PIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining M320 PICs and PIC Cables” on page 276
.
Figure 98: Connecting Fiber-Optic Cable to a PIC
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
M320 PIC Description on page 54
•
Maintaining M320 PICs and PIC Cables on page 276
•
Connecting PIC Cables to the M320 Router on page 169
Replacing an M320 SFP
1.
Removing an M320 SFP on page 241
2.
Installing an M320 SFP on page 242
240 Copyright © 2015, Juniper Networks, Inc.
Chapter 27: Replacing Line Card Components
Removing an M320 SFP
Small form-factor pluggables (SFPs) are transceivers that can be removed from a PIC.
SFPs are hot-insertable and hot-removable. Removing an SFP does not interrupt PIC functioning, but the removed SFP no longer receives or transmits data.
NOTE: When you remove a PIC transceiver, the router continues to function, although the PIC interface being removed no longer functions.
Figure 99: Small Form-Factor Pluggable (SFP)
Connector
Locking pin
NOTE: This procedure applies to both SFP and SFP+ transceivers.
To remove an SFP transceiver (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the
SFP. Have ready a rubber safety cap for the SFP transceiver and the cable.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Label the cable connected to the SFP so that you can later reconnect it to the correct
SFP.
4.
Disconnect the cable from the SFP. Immediately cover the transceiver and the end of the cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
5.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight
Copyright © 2015, Juniper Networks, Inc.
241
M320 Multiservice Edge Router Hardware Guide as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
6.
Pull the ejector handle away from the SFP faceplate to unseat the SFP from the PIC.
Pull the SFP out of the PIC, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: After removing a transceiver from the chassis, wait at least 30 seconds before reinserting it or inserting a transceiver into a different slot.
Installing an M320 SFP
To install a replacement SFP:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Verify that a rubber safety cap covers the SFP transceiver, installing one if necessary.
3.
Orient the SFP over the port in the PIC so that the connector end will enter the slot first and the SFP connector faces the appropriate direction:
• If the PIC has ten SFP ports, the ports are arranged in two columns. The SFP connector faces to the right for ports in the left column, and to the left for ports in the right column.
•
If the PIC has one or two SFP ports, the SFP connector faces to the left.
4.
Slide the SFP into the slot. If there is resistance, remove the SFP and flip it so that the connector faces the other direction.
5.
Remove the rubber safety cap from the transceiver and the end of the cable, and insert the cable into the transceiver.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
242 Copyright © 2015, Juniper Networks, Inc.
Chapter 27: Replacing Line Card Components
6.
Arrange the cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
7.
Verify that the status LEDs on the PIC faceplate indicate that the SFP is functioning correctly (there is an LED for each SFP port). For more information about the PIC
LEDs, see the interface module reference for your device. You can also verify PIC functioning by issuing the show chassis fpc pic-status command.
Related
Documentation
•
M320 PIC Description on page 54
•
M320 Chassis Description on page 7
•
Maintaining M320 PICs and PIC Cables on page 276
Replacing an M320 XENPAK Module
1.
Removing an M320 XENPAK Module on page 243
2.
Installing an M320 XENPAK Module on page 245
Removing an M320 XENPAK Module
To remove a XENPAK module (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the
XENPAK module. Have ready a rubber safety cap for the XENPAK transceiver and the cable.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Label the cable connected to the XENPAK module so that you can later reconnect it to the correct module.
4.
Disconnect the cable from the XENPAK module. Immediately cover the transceiver and the end of the cable with a rubber safety cap.
Copyright © 2015, Juniper Networks, Inc.
243
M320 Multiservice Edge Router Hardware Guide
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
5.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
6.
Unscrew the thumbscrews at the top and bottom of the XENPAK module.
7.
Slide the module out of the PIC and place it in the electrostatic bag or on the antistatic mat.
Figure 100: Removing a XENPAK Module
244 Copyright © 2015, Juniper Networks, Inc.
Chapter 27: Replacing Line Card Components
Installing an M320 XENPAK Module
To install a replacement XENPAK module (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Verify that a rubber safety cap covers the XENPAK transceiver. Install one if necessary.
3.
Orient the XENPAK module so that the optical port faces out, and the transmit (TX) port is above the receive (RX) port (see
).
4.
Slide the XENPAK module into the slot.
5.
Tighten the thumbscrews at the top and bottom of the XENPAK module. Verify that the module is seated properly.
6.
Remove the rubber safety cap from the transceiver and the end of the cable. Insert the cable into the transceiver.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
7.
Arrange the cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
8.
Verify that the status LEDs on the PIC faceplate indicate that the XENPAK module is functioning correctly. For more information about the PIC LEDs, see the interface module reference for your device. You can also verify PIC functioning by issuing the show chassis fpc pic-status command.
Copyright © 2015, Juniper Networks, Inc.
245
M320 Multiservice Edge Router Hardware Guide
Figure 101: Installing a XENPAK Module
Related
Documentation
•
M320 PIC Description on page 54
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
Maintaining M320 PICs and PIC Cables on page 276
•
M320 Chassis Description on page 7
246 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 28
Replacing Power System Components
•
Replacing an M320 AC Power Supply on page 247
•
Replacing an M320 DC Power Supply on page 250
•
Replacing an M320 AC Power Supply Cord on page 254
•
Replacing an M320 DC Power Supply Cable on page 255
Replacing an M320 AC Power Supply
1.
Removing an M320 AC Power Supply on page 247
2.
Installing an M320 AC Power Supply on page 248
Removing an M320 AC Power Supply
The power supplies are located at the rear of the chassis below the SIBs. Each power supply weighs approximately 10 lb (4.5 kg).
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
To remove an AC power supply:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Switch power switch on the AC power supply faceplate to the off position (O).
3.
Unplug the power cord from the power source receptacle.
4.
Remove the cable restraint from the right edge of the power supply faceplate by removing its retainer screw.
5.
Unplug the power cord from the appliance inlet on the power supply faceplate.
6.
Loosen the captive screw on each side of the power supply faceplate completely.
7.
Grasp the flange on each side of the power supply faceplate, placing your hand between the flange and the chassis.
8.
Pull firmly to start removing the power supply. Slide it halfway out of the chassis (see
).
Copyright © 2015, Juniper Networks, Inc.
247
M320 Multiservice Edge Router Hardware Guide
WARNING: Do not touch the power connectors on the rear of the power supply (see
Figure 103 on page 248 ). They can contain dangerous voltages.
9.
Place one hand underneath the power supply to support it, and slide it completely out of the chassis.
CAUTION: Each power supply weighs approximately 10 lb (4.5 kg). Be prepared to support the full weight of the power supply as you remove it from the router.
Figure 102: Removing an AC Power Supply
Figure 103: Rear of the Power Supply Showing Midplane Connector
Installing an M320 AC Power Supply
To install an AC power supply (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Switch the power switch on the AC power supply faceplate to the off position (O).
3.
Using both hands, slide the power supply into the chassis until you feel resistance.
248 Copyright © 2015, Juniper Networks, Inc.
Chapter 28: Replacing Power System Components
4.
Firmly push the power supply into the chassis until it comes to a stop. The power supply faceplate should be flush with any adjacent power supply faceplates.
5.
Tighten the captive screws on each side of the power supply faceplate to secure the power supply in the chassis.
6.
Insert the appliance coupler end of a power cord into the appliance inlet on the power supply faceplate.
7.
Remove the cable restraint from the right edge of the power supply faceplate by removing its retainer screw.
8.
Wrap the cable restraint around the power cord, then slide it along the power cord to a position that enables you to reinstall it in the power supply faceplate.
9.
Reinstall the cable restraint by tightening its retainer screw partway into the power supply faceplate.
10.
Carefully pull the AC power cord through the cable restraint until you have the desired amount of slack in the power cord.
11.
Tighten the cable restraint retainer screw to hold the power cord in place.
12.
Insert the power cord plug into an AC power source receptacle. Verify that the power cord does not block access to router components or drape where people could trip on it.
13.
Switch the powers seitch on the power supply faceplate to the on position (|). Verify that the OUTPUT OK status LED on the power supply faceplate blinks, then lights steadily approximately 1 minute after you switch the power switch on.
Figure 104: Installing an AC Power Supply
Related
Documentation
•
M320 AC Power Supplies Description on page 73
•
M320 AC Power Electrical Specifications on page 101
•
Connecting Power to an AC-Powered M320 Router on page 173
•
M320 AC Power Electrical Safety Guidelines on page 345
Copyright © 2015, Juniper Networks, Inc.
249
M320 Multiservice Edge Router Hardware Guide
•
M320 AC Power Electrical Safety Warning on page 346
Replacing an M320 DC Power Supply
1.
Removing an M320 DC Power Supply on page 250
2.
Installing an M320 DC Power Supply on page 252
Removing an M320 DC Power Supply
The power supplies are located at the rear of the chassis below the SIBs. Each power supply weighs approximately 10 lb (4.5 kg).
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
To remove a DC power supply:
1.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the circuit breaker on the DC power supply faceplate to the off position (O).
4.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
5.
Remove the nuts and washers from the terminal studs (see
).
(Use a 7/16-in. (11 mm) nut driver.)
250 Copyright © 2015, Juniper Networks, Inc.
Chapter 28: Replacing Power System Components
Figure 105: Disconnecting Power Cables from the DC Power Supply
6.
Remove the cable lugs from the terminal studs.
7.
Loosen the captive screws on the cable restraints on the right edge of the power supply faceplate.
8.
Carefully move the power cables out of the way.
9.
Loosen the captive screw on each side of the power supply faceplate completely.
10.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
11.
Pull firmly to start removing the power supply. Slide it halfway out of the chassis (see
WARNING: Do not touch the power connectors on the rear of the power supply (see
“Removing an M320 AC Power Supply” on page 247 ). They can
contain dangerous voltages.
12.
Place one hand underneath the power supply to support it, and slide it completely out of the chassis.
Copyright © 2015, Juniper Networks, Inc.
251
M320 Multiservice Edge Router Hardware Guide
CAUTION: Each power supply weighs approximately 10 lb (4.5 kg). Be prepared to support the full weight of the power supply as you remove it from the router.
Figure 106: Removing a DC Power Supply
Installing an M320 DC Power Supply
To install a DC power supply (see
):
1.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during installation.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the circuit breaker on the DC power supply faceplate to the off position (O).
4.
Using both hands, slide the power supply into the chassis until you feel resistance.
5.
Firmly push the power supply into the chassis until it comes to a stop. The power supply faceplate should be flush with any adjacent power supply faceplates.
6.
Tighten the captive screws on each side of the power supply faceplate to secure the power supply in the chassis.
7.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
8.
Remove the nuts and washers from the terminal studs.
252 Copyright © 2015, Juniper Networks, Inc.
Chapter 28: Replacing Power System Components
9.
Attach the lugs on the DC source power cables to the terminal studs.
a.
Attach the lugs on the positive (+) DC source power cables to the terminal studs.
b.
Attach the lugs on the negative (–) DC source power cables to the terminal studs.
Secure each cable lug to the terminal stud, first with a washer, then with a nut. Use a
7/16-in. (11 mm) nut driver or socket wrench to tighten the nut. Apply between 23 lb-in.
(2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
NOTE: The DC power supplies in slots PEM0 and PEM1 must be powered by dedicated power feeds derived from feed A, and the DC power supplies in slots PEM2 and PEM3 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed
A/B feed redundancy for the system.
10.
Loosen the captive screw on the cable restraint on the right edge of the power supply faceplate.
11.
Route the positive and negative DC power cables through the top and bottom of the cable restraint.
12.
Tighten the cable restraint captive screw to hold the power cables in place.
13.
Verify that the ground and power cabling are correct, that they are not touching or blocking access to router components, and that they do not drape where people could trip on them.
14.
Replace the clear plastic cover over the terminal studs on the faceplate.
15.
Switch on the external circuit breakers to provide voltage to the DC power source cable leads.
16.
Switch the circuit breaker on the power supply faceplate to the on position (|). Verify that the OUTPUT OK status LED on the power supply faceplate blinks, then lights steadily approximately 1 minute after you switch the power supply circuit breaker on.
Figure 107: Installing a DC Power Supply
Copyright © 2015, Juniper Networks, Inc.
253
M320 Multiservice Edge Router Hardware Guide
Figure 108: Connecting Power Cables to the DC Power Supply
Related
Documentation
•
M320 DC Power Supplies Description on page 74
•
M320 DC Power Electrical Specifications on page 105
•
Connecting Power to a DC-Powered M320 Router on page 174
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Replacing an M320 AC Power Supply Cord
To replace the power cord for an AC power supply:
1.
Locate a replacement power cord with the type of plug appropriate for your geographical location (see
“M320 AC Power Cord Specifications” on page 102 ).
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the power switch on the power supply faceplate to the off position (O).
4.
Unplug the power cord from the power source receptacle.
5.
Remove the cable restraint from the right edge of the power supply faceplate by removing its retainer screw.
6.
Remove the cable restraint from the power cord and save it so you can use it on the replacement power cord.
7.
Unplug the power cord from the appliance inlet on the power supply faceplate.
8.
Insert the appliance coupler end of the replacement power cord into the appliance inlet on the power supply faceplate.
9.
Wrap the cable restraint around the power cord, then slide it along the power cord to a position that enables you to reinstall it in the power supply faceplate.
10.
Reinstall the cable restraint by tightening its retainer screw partway into the power supply faceplate.
11.
Carefully pull the AC power cord through the cable restraint until you have the desired amount of slack in the power cord.
254 Copyright © 2015, Juniper Networks, Inc.
Chapter 28: Replacing Power System Components
12.
Tighten the cable restraint retainer screw to hold the power cord in place.
13.
Insert the power cord plug into an AC power source receptacle. Verify that the power cord does not block access to router components or drape where people could trip on it.
14.
Switch the power switch on the power supply faceplate to the on position (|). Verify that the OUTPUT OK status LED on the power supply faceplate blinks, then lights steadily approximately 1 minute after you switch the power switch on.
Related
Documentation
•
M320 AC Power Supplies Description on page 73
•
M320 AC Power Electrical Specifications on page 101
•
Connecting Power to an AC-Powered M320 Router on page 173
•
M320 AC Power Electrical Safety Guidelines on page 345
•
M320 AC Power Electrical Safety Warning on page 346
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Replacing an M320 DC Power Supply Cable
To replace a power cable for a DC power supply:
1.
Locate a replacement power cable that meets the specifications defined in
DC Power Cable Specifications” on page 107
.
CAUTION: A licensed electrician must attach a cable lug to the power cable that you supply. A cable with an incorrectly attached lug can damage the router (for example, by causing a short circuit).
2.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Switch the circuit breaker on the DC power supply faceplate to the off position (O).
5.
Remove the power cable from the DC power source.
6.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
Copyright © 2015, Juniper Networks, Inc.
255
M320 Multiservice Edge Router Hardware Guide
7.
Remove the nuts and washers from the terminal studs (see
(Use a 7/16-in. (11 mm) nut driver.)
8.
Remove the cable lug from the terminal studs.
9.
Loosen the captive screw on the cable restraint on the right edge of the power supply faceplate.
10.
Carefully move the power cable out of the way.
11.
Attach the lug on the replacement power cable to the terminal studs, making sure the cable is not touching or in the way of any router components.
12.
Attach the lugs on the DC source power cables to the terminal studs.
a.
Attach the lugs on the positive (+) DC source power cables to the terminal studs.
b.
Attach the lugs on the negative (–) DC source power cables to the terminal studs.
Secure each cable lug to the terminal stud, first with a washer, then with a nut. Use a
7/16-in. (11 mm) nut driver or socket wrench to tighten the nut. Apply between 23 lb-in.
(2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
NOTE: The DC power supplies in slots PEM0 and PEM1 must be powered by dedicated power feeds derived from feed A, and the DC power supplies in slots PEM2 and PEM3 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed
A/B feed redundancy for the system.
13.
Route the power cable through the cable restraint.
14.
Tighten the cable restraint captive screw to hold the power cable in place.
15.
Replace the clear plastic cover over the terminal studs on the faceplate.
16.
Attach the power cable to the DC power source.
17.
Verify that the DC source power cabling and grounding cabling are correct, that they are not touching or blocking access to router components, and that they do not drape where people could trip on them.
18.
Switch the circuit breaker on the DC power supply faceplate to the on position (|).
Verify that the OUTPUT OK status LED on the power supply faceplate blinks, then lights steadily approximately 1 minute after you switch the power supply circuit breaker on.
256 Copyright © 2015, Juniper Networks, Inc.
Chapter 28: Replacing Power System Components
Figure 109: Disconnecting or Connecting a Power Cable from a DC Power
Supply
Related
Documentation
•
M320 DC Power Supplies Description on page 74
•
M320 DC Power Electrical Specifications on page 105
•
Connecting Power to a DC-Powered M320 Router on page 174
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Copyright © 2015, Juniper Networks, Inc.
257
M320 Multiservice Edge Router Hardware Guide
258 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 29
Replacing Switch Fabric Components
•
Replacing an M320 SIB on page 259
Replacing an M320 SIB
1.
Removing an M320 SIB on page 259
2.
Installing an M320 SIB on page 260
Removing an M320 SIB
Two to four SIBs are installed in the router. The SIBs are located in the rear of the chassis in the slots marked SIB0 through SIB3. SIBs are hot-insertable and hot-removable. Each
SIB weighs approximately 4 lb (1.8 kg).
To remove a SIB (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Press the online/offline button on the SIB faceplate. Press and hold down the button until the green OK LED goes out (about 5 seconds).
4.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on each side of the SIB faceplate.
5.
Flip the ejector handles outward to unseat the SIB.
6.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of the way out of the chassis.
7.
Place one hand underneath the SIB to support it, and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
Copyright © 2015, Juniper Networks, Inc.
259
M320 Multiservice Edge Router Hardware Guide
Figure 110: Removing a SIB
Installing an M320 SIB
To install a SIB into the rear of the chassis (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Place one hand underneath the SIB to support it. With the other hand, hold one of the ejector handles on the SIB faceplate.
3.
Carefully align the sides of the SIB with the guides inside the chassis.
4.
Slide the SIB into the chassis, carefully ensuring that it is correctly aligned.
5.
Grasp both ejector handles and press them inward to seat the SIB.
6.
Tighten the captive screws on the ejector handles.
7.
Press the offline/online button until the green OK LED blinks to bring the SIB online.
8.
To verify that the SIB is functioning normally, check the LEDs on its faceplate. The green OK LED should light steadily a few minutes after the SIB is installed. If the FAIL
LED is lit steadily, remove and install the SIB again. If the FAIL LED still lights steadily, the SIB is not functioning properly. Contact your customer support representative.
To check the status of the SIBs, issue the following CLI command: user@host> show chassis environment sib
260 Copyright © 2015, Juniper Networks, Inc.
Figure 111: Installing a SIB
Chapter 29: Replacing Switch Fabric Components
Related
Documentation
•
M320 SIB Description on page 79
•
Maintaining the M320 SIBs on page 279
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Copyright © 2015, Juniper Networks, Inc.
261
M320 Multiservice Edge Router Hardware Guide
262 Copyright © 2015, Juniper Networks, Inc.
PART 5
Maintaining the Chassis and Components
•
Routine Maintenance Procedures on page 265
•
Maintaining Components and Cables on page 267
Copyright © 2015, Juniper Networks, Inc.
263
M320 Multiservice Edge Router Hardware Guide
264 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 30
Routine Maintenance Procedures
•
Routine Maintenance Procedures for the M320 Router on page 265
Routine Maintenance Procedures for the M320 Router
Purpose For optimum router performance, perform preventive maintenance procedures.
NOTE: Some components, such as the Connector Interface Panel (CIP) and the craft interface, require no maintenance.
Action On a regular basis:
•
Inspect the installation site for moisture, loose wires or cables, and excessive dust.
Make sure that airflow is unobstructed around the router and into the air intake vents.
•
Check the status-reporting devices on the craft interface: system alarms, LEDs, and
LCD.
•
Inspect the air filters at the bottom front and left rear of the router, replacing them every 6 months. Do not run the router for more than a few minutes without the air filters in place.
Related
Documentation
•
M320 Chassis Description on page 7
•
M320 Craft Interface Description on page 15
•
Maintaining the M320 Air Filters on page 267
Copyright © 2015, Juniper Networks, Inc.
265
M320 Multiservice Edge Router Hardware Guide
266 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 31
Maintaining Components and Cables
•
Tools and Parts Required to Maintain the M320 Hardware Components on page 267
•
Maintaining the M320 Air Filters on page 267
•
Maintaining the M320 Fan Trays on page 268
•
Maintaining the M320 Host Subsystem on page 269
•
Maintaining M320 FPCs on page 270
•
Holding and Storing M320 FPCs on page 272
•
Maintaining M320 PICs and PIC Cables on page 276
•
Maintaining the M320 Power Supplies on page 278
•
Maintaining the M320 SIBs on page 279
Tools and Parts Required to Maintain the M320 Hardware Components
To maintain the T320 hardware components, you need the following tools and parts:
•
ESD grounding wrist strap
• Flat-blade (–) screwdriver
• Phillips (+) screwdriver, number 1
•
Phillips (+) screwdriver, number 2
Related
Documentation
•
Contacting Customer Support on page 297
•
M320 Router Description on page 3
•
M320 Chassis Description on page 7
Maintaining the M320 Air Filters
Purpose For optimum cooling, verify the condition of the air filters.
Action On a regular basis:
•
Check the air filters for dust and debris. Replace the filter elements . The filter elements degrade over time, so the filter elements in use, as well as spares, must be replaced
Copyright © 2015, Juniper Networks, Inc.
267
M320 Multiservice Edge Router Hardware Guide every six months. For procedures to replace the air filters, see
•
Spare filter elements should be used within 1 year of manufacture. Check the date of manufacture printed on the filter. Store spare filter elements in a dark, cool, and dry place. Storing the filter elements at higher temperatures, or where they can be exposed to ultraviolet (UV) radiation, hydrocarbon emissions, or vapors from solvents, can significantly reduce their life.
CAUTION: Always keep both air filters in place while the router is operating.
Because the fans are very powerful, they could pull small bits of wire or other materials into the router through the unfiltered air intake. This could damage the router components.
Related
Documentation
•
M320 Cooling System Description on page 21
•
Troubleshooting the M320 Cooling System on page 287
•
Replacing an M320 Air Filter on page 203
•
Replacing an M320 Fan Tray on page 208
Maintaining the M320 Fan Trays
Purpose For optimum cooling, verify the condition of the fans.
Action On a regular basis:
•
Monitor the status of the fans. The fan trays each contain multiple fans that work in unison to cool the router components. If one fan fails, the host subsystem adjusts the speed of the remaining fans to maintain proper cooling. A red alarm is triggered when a fan fails, and a yellow alarm is triggered when a fan tray is removed.
•
To display the status of the fans, issue the show chassis environment command. The output is similar to the following: user@host> show chassis environment
Class Item Status Measurement
...
Fans Top Left Front fan OK Spinning at normal speed
Top Left Middle fan OK Spinning at normal speed
Top Left Rear fan OK Spinning at normal speed
Top Right Front fan OK Spinning at normal speed
Top Right Middle fan OK Spinning at normal speed
Top Right Rear fan OK Spinning at normal speed
Bottom Left Front fan OK Spinning at normal speed
Bottom Left Middle fan OK Spinning at normal speed
Bottom Left Rear fan OK Spinning at normal speed
Bottom Right Front fan OK Spinning at normal speed
Bottom Right Middle fan OK Spinning at normal speed
Bottom Right Rear fan OK Spinning at normal speed
Fourth Blower from top OK Spinning at normal speed
268 Copyright © 2015, Juniper Networks, Inc.
Chapter 31: Maintaining Components and Cables
Bottom Blower OK Spinning at normal speed
Middle Blower OK Spinning at normal speed
Top Blower OK Spinning at normal speed
Second Blower from top OK Spinning at normal speed
...
Related
Documentation
•
M320 Cooling System Description on page 21
•
Troubleshooting the M320 Cooling System on page 287
•
Replacing an M320 Air Filter on page 203
•
Replacing an M320 Fan Tray on page 208
Maintaining the M320 Host Subsystem
Purpose For optimum router performance, verify the condition of the host subsystem. The host subsystem comprises a Routing Engine and up to two adjacent CBs functioning together.
Action On a regular basis:
•
Check the host subsystem LEDs (RE0 and RE1) on the craft interface. If the red RE0 or
RE1
LED is lit, look at the LED display to get more information about the cause of the problem. For more information about the LEDs and the display, see
Interface Description” on page 15
.
•
Check the LED display on the craft interface to view information about the router temperature and the status of the Routing Engines.
•
Check the LEDs on the CB faceplate to see information about the CB.
•
To check the status of the Routing Engines, issue the show chassis routing-engine command. The output is similar to the following: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Backup
Election priority Master (default)
Temperature 50 degrees C / 122 degrees F
DRAM 2048 MB
Memory utilization 10 percent
CPU utilization:
User 25 percent
Background 0 percent
Kernel 38 percent
Interrupt 4 percent
Idle 33 percent
Model RE-4.0
Serial ID 212058900125
Start time 2003-09-30 16:34:15 PDT
Uptime 18 hours, 57 minutes, 9 seconds
Routing Engine status:
Slot 1:
Current state Master
Election priority Backup (default)
Temperature 29 degrees C / 84 degrees F
DRAM 2048 MB
Copyright © 2015, Juniper Networks, Inc.
269
M320 Multiservice Edge Router Hardware Guide
Memory utilization 11 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 1 percent
Interrupt 0 percent
Idle 99 percent
Model RE-4.0
Serial ID 212047100107
Start time 2003-09-30 13:04:27 PDT
Uptime 22 hours, 27 minutes, 8 seconds
Load averages: 1 minute 5 minute 15 minute
0.01 0.01 0.00
•
To check the status of the CBs, issue the show chassis environment cb command. The output is similar to the following: user@host> show chassis environment cb
CB 0 status:
State Online Standby
Temperature 33 degrees C / 91 degrees F
Power:
1.8 V 1816 mV
2.5 V 2477 mV
3.3 V 3278 mV
4.6 V 4615 mV
5.0 V 5023 mV
12.0 V 11511 mV
3.3 V bias 3286 mV
8.0 V bias 7257 mV
BUS Revision 16
FPGA Revision 39
CB 1 status:
State Online Master
Temperature 28 degrees C / 82 degrees F
Power:
1.8 V 1809 mV
2.5 V 2471 mV
3.3 V 3304 mV
4.6 V 4610 mV
5.0 V 5003 mV
12.0 V 11555 mV
3.3 V bias 3301 mV
8.0 V bias 7413 mV
BUS Revision 12
FPGA Revision 15
For more information about using the CLI, see the Junos OS manuals.
Related
Documentation
•
M320 Host Subsystem Description on page 23
•
Taking the M320 Host Subsystem Offline on page 213
Maintaining M320 FPCs
Purpose For optimum router performance, verify the condition of the FPCs. The router can have up to eight FPCs mounted vertically in the FPC card cage at the front of the chassis.
270 Copyright © 2015, Juniper Networks, Inc.
Chapter 31: Maintaining Components and Cables
Action On a regular basis:
•
Check the LCD on the craft interface and the LEDs on the craft interface directly above each FPC slot. The green LED labeled OK lights steadily when an FPC is functioning normally.
During normal operation:
•
The green OK LED above the FPC on the craft interface lights steadily when the FPC is online and functioning normally.
•
The green OK LED blinks during startup.
•
Issue the CLI show chassis fpc command to check the status of installed FPCs. As shown in the sample output, the value Online in the column labeled State indicates that the FPC is functioning normally: user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 37 2 0 256 9 41
1 Empty
2 Online 37 3 0 256 8 41
3 Empty
4 Empty
5 Empty
6 Empty
7 Empty
For more detailed output, add the detail option. The following example also specifies a slot number (0), which is optional: user@host> show chassis fpc detail 0
Slot 0 information:
State Online
Temperature 37 degrees C / 98 degrees F
Total CPU DRAM 256 MB
Total SRAM 28 MB
Total SDRAM 256 MB
Start time: 2003-10-01 04:19:30 PDT
Uptime: 10 days, 7 hours, 16 minutes, 48 seconds
For further description of the output from the commands, see the CLI Explorer .
Related
Documentation
•
M320 Chassis Description on page 7
•
M320 Flexible PIC Concentrator (FPC) Description on page 49
•
M320 Craft Interface FPC LEDs and Online/Offline Buttons on page 18
•
Troubleshooting the M320 FPCs on page 289
•
Replacing an M320 FPC on page 227
Copyright © 2015, Juniper Networks, Inc.
271
M320 Multiservice Edge Router Hardware Guide
Holding and Storing M320 FPCs
•
•
Holding M320 FPCs
CAUTION: Many components on the FPC are fragile. Failure to handle FPCs as specified in this document can cause irreparable damage.
NOTE: An FPC configured with PICs installed can weigh as much as An empty
FPC1 or FPC2 weighs 15 lb (6.8 kg), and an empty FPC3 weighs 16 lb (7.3 kg).
A fully configured FPC can weigh up to 29 lb (13.2 kg). Be prepared to accept the full weight of the FPC as you lift it.
CAUTION: To prevent damage when handling or carrying FPCs:
• As you carry the FPC, do not bump it against anything. FPC components are fragile.
•
Do not grasp the FPC anywhere except places that this document indicates.
In particular, never grasp the connector edge, especially at the power connector in the corner where the connector and bottom edges meet (see
•
Do not carry the FPC by the faceplate with only one hand (see
• Do not rest any edge of an FPC directly against a hard surface (see
). If you must rest the FPC temporarily on an edge while changing its orientation between vertical and horizontal, use your hand as a cushion between the edge and the surface.
272 Copyright © 2015, Juniper Networks, Inc.
Chapter 31: Maintaining Components and Cables
Figure 112: Do Not Grasp the Connector Edge
Figure 113: Do Not Carry an FPC with Only One Hand
Copyright © 2015, Juniper Networks, Inc.
273
M320 Multiservice Edge Router Hardware Guide
Figure 114: Do Not Rest the FPC on an Edge
You hold an FPC vertically when installing it into the chassis. To hold an FPC vertically
(see
):
1.
Orient the FPC so that the faceplate faces you.
2.
Place one hand around the FPC faceplate about a quarter of the way down from the top edge. To avoid deforming the electromagnetic interference (EMI) shielding strip, do not press hard on it.
3.
Place your other hand at the bottom edge of the FPC. If the FPC has heat sinks about midway between the faceplate and connector edge, place your other hand against the heat sinks.
274 Copyright © 2015, Juniper Networks, Inc.
Figure 115: Holding an FPC Vertically
Chapter 31: Maintaining Components and Cables
Storing M320 FPCs
When an FPC is not installed in a router, the FPC must be either stored in the container in which a spare FPC is shipped or stored horizontally with the component-side up on a flat, stable surface. When you store an FPC on a horizontal surface or in the shipping container, always place it inside an antistatic bag. Because the FPC is heavy and because antistatic bags are fragile, inserting the FPC into the bag is easier with two people. The storage procedures are as follows:
•
When storing an FPC with two people, one person holds the FPC in the horizontal position with the faceplate facing their body, the other person slides the opening of the bag over the FPC connector edge.
• When storing an FPC with one person, you must insert the FPC into a bag by yourself.
First lay the FPC horizontally on a flat, stable surface, component-side up. Orient the
FPC with the faceplate facing you. Carefully insert the FPC connector edge into the opening of the bag, and pull the bag toward you to cover the FPC.
CAUTION: To prevent damage when storing FPCs:
•
Never lay an FPC component-side down.
Copyright © 2015, Juniper Networks, Inc.
275
M320 Multiservice Edge Router Hardware Guide
Figure 116: Do Not Stack FPCs
•
Never stack an FPC under or on top of any other component (see
Related
Documentation
•
M320 Flexible PIC Concentrator (FPC) Description on page 49
•
Troubleshooting the M320 FPCs on page 289
•
Replacing an M320 FPC on page 227
Maintaining M320 PICs and PIC Cables
Purpose For optimum router performance, verify the condition of the PICs and PIC cables.
Action On a regular basis:
•
Check the LEDs on PIC faceplates. The meaning of the LED states differs for various
PICs. For more information, see the M320 Multiservice Edge Router Interface Module
Reference. If the FPC that houses the PIC detects a PIC failure, the FPC generates an alarm message to be sent to the Routing Engine.
•
Issue the CLI show chassis fpc pic-status command. The PIC slots in an FPC are numbered from 0 through 3, top to bottom: user@host> show chassis fpc pic-status
Slot 0 Online
PIC 0 4x OC-3 SONET, MM
PIC 1 1x CSTM1, SMIR
PIC 3 2x OC-3 ATM, MM
Slot 1 Online
PIC 0 1x OC-12 SONET, MM
PIC 1 1x OC-12 ATM, MM
PIC 2 2x OC-3 ATM, MM
PIC 3 2x OC-3 ATM, MM
For further description of the output from the command, see the CLI Explorer .
•
Use the cable management system (shown in
“M320 Chassis Description” on page 7 )
to support cables and prevent cables from dislodging or developing stress points.
276 Copyright © 2015, Juniper Networks, Inc.
Chapter 31: Maintaining Components and Cables
•
Place excess cable out of the way in the cable management system. Do not allow fastened loops of cable to dangle from the connector or cable management system, because this stresses the cable at the fastening point. Putting fasteners on the loops helps to maintain their shape.
•
Keep the cable connections clean and free of dust and other particles, which can cause drops in the received power level. Always inspect cables and clean them if necessary before connecting an interface.
•
Label both ends of PIC cables to identify them.
•
Use the cable guards and cable cover to protect the PIC and CIP cables from rubbing against the front edges of the chassis and to prevent them from being dislodged from the PIC and CIP ports.
The following guidelines apply specifically to fiber-optic cable:
•
When you unplug a fiber-optic cable from a PIC, always place a rubber safety plug over the transceiver on the PIC faceplate and on the end of the cable.
•
Anchor fiber-optic cable to avoid stress on the connectors. When attaching fiber to a
PIC, be sure to secure the fiber so it is not supporting its own weight as it hangs to the floor. Never let fiber-optic cable hang free from the connector.
•
Avoid bending fiber-optic cable beyond its bend radius. An arc smaller than a few inches can damage the cable and cause problems that are difficult to diagnose.
•
Frequent plugging and unplugging of fiber-optic cable into and out of optical instruments, such as ATM or SONET/SDH analyzers, can cause damage to the instruments that is expensive to repair. Instead, attach a short fiber extension to the optical equipment. Any wear and tear due to frequent plugging and unplugging is then absorbed by the short fiber extension, which is easy and inexpensive to replace.
•
Keep fiber-optic cable connections clean. Small microdeposits of oil and dust in the canal of the transceiver or cable connector could cause loss of light, reducing signal power and possibly causing intermittent problems with the optical connection.
To clean the transceivers, use an appropriate fiber-cleaning device, such as RIFOCS
Fiber Optic Adaptor Cleaning Wands (part number 946). Follow the directions for the cleaning kit you use.
After you have cleaned the transceiver on the fiber-optic PIC, make sure that the connector tip of the fiber-optic cable is clean. Use only an approved alcohol-free fiber-optic cable cleaning kit, such as the Opptex Cletop-S
®
Fiber Cleaner. Follow the directions for the cleaning kit you use.
Related
Documentation
•
M320 PIC Description on page 54
•
Replacing M320 PIC Cables on page 237
•
Troubleshooting the M320 FPCs on page 289
Copyright © 2015, Juniper Networks, Inc.
277
M320 Multiservice Edge Router Hardware Guide
Maintaining the M320 Power Supplies
Purpose For optimum router performance, verify the condition of the power supplies.
Action On a regular basis:
•
The power supplies require an unobstructed airflow at both the front and rear of the chassis. Periodically check the site to ensure that both the air intake at the bottom front of the chassis and the exhaust from the power supply faceplates are unobstructed.
•
Periodically inspect the site to ensure that the grounding cable, DC power cables, and
AC power cords connected to the router are securely in place and that no moisture is accumulating near the router. To review grounding and site wiring requirements for the router, see
“M320 Chassis Grounding Cable and Lug Specifications” on page 94
and M320 General Electrical Safety Guidelines and Electrical Codes.
•
Make sure that the DC power cables or AC power cords are arranged so that they do not obstruct access to other router components.
•
Check the status of the power supplies by issuing the show chassis environment pem command. The output is similar to the following: user@host> show chassis environment pem
PEM 0 status:
State Online
Temperature OK
DC input OK
Load Less than 20 percent
48.0 V input 54701 mV
48.0 V fan supply 49165 mV
8.0 V bias 8505 mV
5.0 V bias 4991 mV
PEM 1 status:
State Online
Temperature OK
DC input OK
Load Less than 20 percent
48.0 V input 54219 mV
48.0 V fan supply 49002 mV
8.0 V bias 8485 mV
5.0 V bias 4996 mV
PEM 2 status:
State Online
Temperature OK
DC input OK
Load Less than 20 percent
48.0 V input 54701 mV
48.0 V fan supply 49165 mV
8.0 V bias 8505 mV
5.0 V bias 4991 mV
PEM 3 status:
State Online
Temperature OK
DC input OK
Load Less than 20 percent
48.0 V input 54219 mV
48.0 V fan supply 49002 mV
278 Copyright © 2015, Juniper Networks, Inc.
Chapter 31: Maintaining Components and Cables
8.0 V bias 8485 mV
5.0 V bias 4996 mV
NOTE: Isolated DC power supplies share current over the full input operating voltage range.
The current sharing between nonisolated power supplies relies on equal voltages at the power supply input terminals. The M320 system power is divided into two load zones. One load zone consists of PEM0 and PEM2, and the other load zone consists of PEM1 and PEM3. For nonisolated power supplies, load sharing occurs only between the power supplies of each load zone (PEM0 and PEM2 or PEM1 and PEM3). Therefore, the voltages for each nonisolated power supply in a load zone should be equal for current sharing. However, if the voltages do not match, the router operates normally as long as the DC input voltages are within the operating range provided in
“M320 DC Power Electrical Specifications” on page 105 . See
Power Cable Specifications” on page 107
for a typical DC source cabling arrangement.
•
Routinely check the OUTPUT OK and the POWER OK status LEDs on the power supply faceplates and the craft interface. If these output status LEDs are lit, the power supplies are functioning normally. For more information about the power supply LEDs, see
“M320 Power System Description” on page 73 .
•
Check the red and yellow alarm LEDs and the LED display on the craft interface. Power supply failure or removal triggers an alarm that causes one or both of the LEDs to light and an error message to appear on the LED display. You can display the associated error messages by issuing the following CLI command: user@host> show chassis alarms
For a list of possible alarm messages, see
“M320 Chassis and Interface Alarm Messages” on page 285 .
Related
Documentation
•
Troubleshooting the M320 Power System on page 292
•
Replacing an M320 AC Power Supply on page 247
•
Replacing an M320 DC Power Supply on page 250
Maintaining the M320 SIBs
Purpose For optimum router performance, verify the condition of the SIBs.
Action On a regular basis:
•
Observe the status of the SIBs by checking the LEDs on the SIB faceplate or craft interface. For more information on the SIB LEDs, see
and
“M320 Craft Interface SIB LEDs” on page 19
.
Copyright © 2015, Juniper Networks, Inc.
279
M320 Multiservice Edge Router Hardware Guide
280
•
To check the status of the SIBs using the CLI, issue the show chassis environment sib command. The output is similar to the following: user@host> show chassis environment sib
SIB 0 status:
State Online
Temperature 37 degrees C / 98 degrees F
Power:
GROUND 0 mV
1.8 V 1797 mV
2.5 V 2493 mV
3.3 V 3315 mV
1.8 V bias 1789 mV
3.3 V bias 3284 mV
5.0 V bias 5023 mV
8.0 V bias 7452 mV
SIB 1 status:
State Online
Temperature 38 degrees C / 100 degrees F
Power:
GROUND 0 mV
1.8 V 1798 mV
2.5 V 2495 mV
3.3 V 3321 mV
1.8 V bias 1797 mV
3.3 V bias 3289 mV
5.0 V bias 4971 mV
8.0 V bias 7462 mV
SIB 2 status:
State Online
Temperature 38 degrees C / 100 degrees F
Power:
GROUND 0 mV
1.8 V 1810 mV
2.5 V 2492 mV
3.3 V 3327 mV
1.8 V bias 1794 mV
3.3 V bias 3306 mV
5.0 V bias 4996 mV
8.0 V bias 7499 mV
SIB 3 status:
State Online
Temperature 41 degrees C / 105 degrees F
Power:
GROUND 0 mV
1.8 V 1796 mV
2.5 V 2483 mV
3.3 V 3328 mV
1.8 V bias 1802 mV
3.3 V bias 3286 mV
5.0 V bias 4967 mV
8.0 V bias 7570 mV
For more information about using the CLI, see the Junos OS manuals.
Related
Documentation
•
M320 SIB Description on page 79
•
M320 Performance for Different SIB Configurations on page 80
•
Replacing an M320 SIB on page 259
Copyright © 2015, Juniper Networks, Inc.
PART 6
Troubleshooting Hardware
•
Troubleshooting Components on page 283
Copyright © 2015, Juniper Networks, Inc.
281
M320 Multiservice Edge Router Hardware Guide
282 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 32
Troubleshooting Components
•
M320 Troubleshooting Resources Overview on page 283
•
•
M320 Chassis and Interface Alarm Messages on page 285
•
Troubleshooting the M320 Cooling System on page 287
•
Troubleshooting the M320 FPCs on page 289
•
Troubleshooting the M320 Fuses on page 290
•
Troubleshooting the M320 PICs on page 291
•
Troubleshooting the M320 Power System on page 292
M320 Troubleshooting Resources Overview
To troubleshoot an M320 router, you use the Junos OS command-line interface (CLI),
LCD, alarms, devices connected to the alarm relay contacts, and LEDs on both the components and craft interface.
• LEDs—When the Routing Engine detects an alarm condition, it lights the red or yellow alarm LED on the craft interface as appropriate. In addition, you can also use the component-specific LEDs on the craft interface and on the faceplate of a component to troubleshoot the router.
• LCD—When a red or yellow alarm occurs, the cause of the alarm messages is displayed on the craft interface LCD. Use the CLI to display more information about the alarm.
•
Alarm devices connected to the alarm relay contact on the CIP—When a red or yellow alarm occurs, it trips the corresponding alarm relay contact on the CIP.
• CLI—The CLI is the primary tool for controlling and troubleshooting hardware, Junos
OS, routing protocols, and network connectivity. CLI commands display information from routing tables, information specific to routing protocols, and information about network connectivity derived from the ping and traceroute utilities. For information about using the CLI to troubleshoot the Junos OS, see the appropriate Junos OS configuration guide.
•
JTAC—If you need assistance during troubleshooting, you can contact the Juniper
Networks Technical Assistance Center (JTAC) by using the Web or by telephone. If you encounter software problems, or problems with hardware components not discussed here, contact JTAC.
Copyright © 2015, Juniper Networks, Inc.
283
M320 Multiservice Edge Router Hardware Guide
Related
Documentation
•
Contacting Customer Support on page 297
M320 LED Overview
•
Craft Interface LEDs on page 284
•
Craft Interface LEDs
The craft interface displays system status messages and allows you to troubleshoot the router.
LEDs on the craft interface include:
• Host subsystem LEDs—Three LEDs (one green MASTER, one green OK, and one red
FAIL ) indicate the status of each host subsystem. The host subsystem LEDs are located on the upper right of the craft interface, and are labeled RE0 and RE1. For more information, see
“M320 Craft Interface Host Subsystem LEDs” on page 18
.
•
SIB LEDs—Two LEDs (one red FAIL and one green OK) indicate the status of each SIB.
The SIB LEDs are located in the middle of the craft interface, and are labeled 0 through
3
. For more information, see
“M320 Craft Interface SIB LEDs” on page 19 .
•
Power supply LEDs—Two LEDs (one red FAIL and one green OK) indicate the status of each power supply. The power supply LEDs are located in the middle of the craft interface, and are labeled 0 through 3. For more information, see
Power Supply LEDs” on page 19 .
• FPC LEDs—Two LEDs (one red FAIL and one green OK) indicate the status of each
FPC. The FPC LEDs are located along the bottom edge of the craft interface, and are labeled FPC0 through FPC7. For more information, see
“M320 Craft Interface FPC LEDs and Online/Offline Buttons” on page 18 .
•
Alarm LEDs—One large red circular LED and one large yellow triangular LED, located on the upper left of the craft interface, indicate two levels of alarm conditions. You can determine the cause of the alarm condition by looking at the LCD on the craft interface.
For more information, see
“M320 Craft Interface Alarm LEDs and ACO/LT Button” on page 16 .
Component LEDs
The following LEDs are located on various router components and display the status of those components:
• SIB LEDs—Three LEDs on each SIB faceplate—ACTIVE, OK, and FAIL—indicate the status of that SIB.
See
•
CB LEDs—Three LEDs on each CB faceplate indicate the status of that CB. If no LEDs are lit, the CB is not receiving power.
284 Copyright © 2015, Juniper Networks, Inc.
Chapter 32: Troubleshooting Components
M320 Control Board (CB) LEDs on page 46
• PIC LEDs—Each PIC has one or more LEDs that indicates the status of the PIC. For more information, see the M320 Multiservice Edge Router Interface Module Reference.
•
Power supply LEDs—One LED on each power supply faceplate indicates the status of that power supply.
See
“M320 Power Supply LEDs” on page 76
.
Related
Documentation
•
M320 Craft Interface Description on page 15
•
M320 Chassis and Interface Alarm Messages on page 285
.
M320 Chassis and Interface Alarm Messages
In both
and
Table 79 on page 286 , the text in the column labeled
“LCD Message” appears in the LCD. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 78: M320 Chassis Alarm Messages
Component Alarm Type LCD Display Message CLI Message
Fans Red
Fan Failure
Fans Missing
Fan Removed
fan-name Failure
Too many fans missing or failing
fan-name Removed Yellow
Temperature sensors Red
Temperature Hot
Sensor Failure
Temperature Hot
Temperature sensor failure
Power supplies
Yellow
Red
Temperature Warm
PEM pem-number Over Temp
PEM pem-number Output Fail
Temperature Warm
PEM pem-number Over Temperature
PEM pem-number Output Failure
Yellow
PEM pem-number Input Fail
PEM pem-number Removed
PEM pem-number Input Failure
PEM pem-number Removed
Copyright © 2015, Juniper Networks, Inc.
285
M320 Multiservice Edge Router Hardware Guide
Table 78: M320 Chassis Alarm Messages (continued)
Component
SIBs
Host subsystems
CB
Craft interface
Alarm Type
Red
Yellow
Red
Yellow
Red
Yellow
Yellow
LCD Display Message
SIB sib-number Failure
CLI Message
SIB sib-number Fault
SIB sib-number Removed
Spare SIB Failure
Spare SIB Removed
Check SIB
Host host-number Removed
Host host-number Failure
CB cb-number Removed
SIB sib-number Absent
Spare SIB Fault
Spare SIB Absent
Check SIB
Host host-number Removed
Host host-number Failure
CB cb-number Removed
CB cb-number Failure CB cb-number Failure
CB cb-number Ethernet Switch Failure CB cb-number Ethernet Switch Failure
Craft Failure Craft Failure
Table 79: SONET/SDH Interface Alarm Messages
LED Display Message CLI Message
interface-name so-x/x/x BERR-SD
interface-name so-x/x/x BERR-SF
interface-name so-x/x/x LAIS
interface-name so-x/x/x LOF
interface-name so-x/x/x LOL
interface-name so-x/x/x LOP
interface-name so-x/x/x LOS
interface-name so-x/x/x LRDI
interface-name so-x/x/x PAIS
interface-name so-x/x/x PLL
interface-name so-x/x/x - SONET bit error rate defect
interface-name so-x/x/x - SONET bit error rate fault
interface-name so-x/x/x - SONET line AIS
interface-name so-x/x/x - SONET loss of frame
interface-name so-x/x/x - SONET loss of light
interface-name so-x/x/x - SONET loss of pointer
interface-name so-x/x/x - SONET loss of signal
interface-name so-x/x/x - SONET line remote defect indicator
interface-name so-x/x/x - SONET path AIS
interface-name so-x/x/x - SONET PLL lock
286 Copyright © 2015, Juniper Networks, Inc.
Chapter 32: Troubleshooting Components
Table 79: SONET/SDH Interface Alarm Messages (continued)
LED Display Message CLI Message
interface-name so-x/x/x PMIS interface-name so-x/x/x - SONET path mismatch
interface-name so-x/x/x PRDI
interface-name so-x/x/x REI
interface-name so-x/x/x SEF
interface-name so-x/x/x UNEQ
interface-name so-x/x/x - SONET path remote defect indicator
interface-name so-x/x/x - SONET remote error indicator
interface-name so-x/x/x - SONET severely errored frame
interface-name so-x/x/x - SONET unequipped
Related
Documentation
•
M320 Craft Interface Alarm LEDs and ACO/LT Button on page 16
Troubleshooting the M320 Cooling System
The M320 router cooling system comprises two front and one rear fan tray (see
Chassis Description” on page 7
). The front fan trays each contain four fans and are interchangeable. The rear fan tray contains seven fans and is not interchangeable with the front trays. The front fan trays cool the components installed in the front card cage
(the FPCs, PICs, CIP, and midplane). The rear fan tray cools the components installed in the rear card cage (the Routing Engines, CBs, and the SIBs). Each power supply has two fans that cool that power supply.
shows the airflow through the router.
Air filters for both the front and rear fan trays help keep dust and other particles from entering the cooling system. To function properly, the entire cooling system requires an unobstructed airflow and proper clearance around the site, as described in
Preparation Checklist Requirements” on page 85
.
Copyright © 2015, Juniper Networks, Inc.
287
M320 Multiservice Edge Router Hardware Guide
Figure 117: Airflow Through the Chassis
288
During normal operation, the fans in each fan tray function at less than full speed. The
CB constantly monitors the temperatures detected by sensors on the midplane and router components, adjusting the speed of the fans as necessary. If the router temperature exceeds the acceptable maximum, the CB turns off the power supplies. The following conditions automatically cause the fans to run at full speed and also trigger the indicated alarm:
• A fan fails (red alarm).
•
One of the fan trays is removed (yellow alarm).
•
The router temperature exceeds the “temperature warm” threshold (yellow alarm).
•
The temperature of the router exceeds the maximum (“temperature hot”) threshold
(red alarm and automatic shutdown of the power supplies).
To troubleshoot the fans, follow these guidelines:
• If the red alarm LED on the craft interface lights, find the source of the problem by looking at the display on the craft interface. The number of alarm conditions, as well as the source of each alarm, appears on the screen.
•
Use the CLI to check the status of the fans. For example, you can issue the following command to get information about the source of an alarm condition: user@host> show chassis alarms
For information about the alarms, see
“M320 Chassis and Interface Alarm Messages” on page 285 .
•
Place your hand near the exhaust vents at the rear of the chassis to determine whether the fans are pushing air out of the chassis.
Copyright © 2015, Juniper Networks, Inc.
Chapter 32: Troubleshooting Components
•
If the OUTPUT OK LED on one or more of the power supplies (or the corresponding
POWER OK
LED on the craft interface) is not lit, check the power supply fans to see if they are operating.
• If all power supplies have failed, the system temperature might have exceeded the threshold, causing the system to shut down.
•
If the display on the craft interface lists only one fan failure and the other fans are functioning normally, the fan is probably faulty and you need to replace the fan tray, as described in
“Replacing an M320 Fan Tray” on page 208 .
Related
Documentation
•
M320 Cooling System Description on page 21
•
Maintaining the M320 Fan Trays on page 268
•
Maintaining the M320 Air Filters on page 267
•
Replacing an M320 Air Filter on page 203
•
Replacing an M320 Fan Tray on page 208
Troubleshooting the M320 FPCs
As soon as an FPC is seated in an operating M320 router, the Routing Engine downloads the FPC software to it. The FPC then runs diagnostics and enables the PICs housed on it. During this time, the green LED labeled STATUS above the FPC on the craft interface blinks. When the FPC is online and functioning normally, the STATUS LED lights steadily.
To troubleshoot the FPCs:
• If the red FAIL LED above the FPC is on, look at the display on the craft interface to check the status of the FPC and the PICs that are plugged into it.
•
Make sure the FPC is properly seated in the midplane. Check that each ejector handle has been turned clockwise and is tight. Use a screwdriver to check that the screws inside the ejector handles are tight.
• To check the status of an FPC, use the following CLI command: user@host> show chassis fpc
To display more detailed information, use the following option: user@host> show chassis fpc detail
Related
Documentation
•
M320 Flexible PIC Concentrator (FPC) Description on page 49
•
M320 Craft Interface Description on page 15
•
Replacing an M320 Craft Interface on page 197
Copyright © 2015, Juniper Networks, Inc.
289
M320 Multiservice Edge Router Hardware Guide
Troubleshooting the M320 Fuses
The router uses fuses from the Cooper Bussman brand GMT series for the CB, SIBs, and
FPCs. The fuses are located in the rear of the midplane behind the power supply in slot
PEM0 . When the fuse for a component blows, the component stops functioning even though it is installed correctly and the power supplies are providing power to the router.
shows the location of the fuses in the rear of the midplane for each component. (The labels shown in the figure do not appear on the actual fuses—the clear cover on every fuse reads BUSS GMT-X—and might not match the labels on the midplane.
Ignore the labels on the midplane.)
Figure 118: Fuses in the Midplane
290 Copyright © 2015, Juniper Networks, Inc.
Chapter 32: Troubleshooting Components
When a fuse has blown but the power supplies are still delivering power to the router, the yellow LED below the fuse lights. The colored indicator bulb inside the fuse becomes visible through the clear cover on the fuse.
NOTE: The LEDs are each about 0.1in. (2 mm) square. They might be difficult to see when not lit.
A blown fuse can cause a component to fail even though it is correctly installed and the power supplies are functioning. Check for a blown fuse in the following circumstances:
•
The LED that indicates normal operation for the component fails to light.
• The appropriate CLI show chassis environment command indicates that the component is installed but is not receiving power.
Related
Documentation
•
•
M320 Chassis and Interface Alarm Messages on page 285
Troubleshooting the M320 PICs
To troubleshoot the PICs:
• To check the status of each port on a PIC, look at the LED located on the PIC faceplate.
For information about the meaning of LED states on different PICs, see the M320
Multiservice Edge Router Interface Module Reference.
• To check the status of a PIC, issue the following CLI command. The PIC slots in the
FPC are numbered from 0 through 3, top to bottom: user@host> show chassis fpc pic-status
Slot 0 Online
PIC 0 4x OC-3 SONET, MM
PIC 1 1x CSTM1, SMIR
PIC 3 2x OC-3 ATM, MM
Slot 1 Online
PIC 0 1x OC-12 SONET, MM
PIC 1 1x OC-12 ATM, MM
PIC 2 2x OC-3 ATM, MM
PIC 3 2x OC-3 ATM, MM
For further description of the output from the command, see the
CLI Explorer
.
Related
Documentation
•
M320 PIC Description on page 54
•
Maintaining M320 PICs and PIC Cables on page 276
•
Replacing M320 PIC Cables on page 237
Copyright © 2015, Juniper Networks, Inc.
291
M320 Multiservice Edge Router Hardware Guide
Troubleshooting the M320 Power System
To verify that a power supply is functioning normally, perform the following steps:
• Check the OUTPUT OK LED on each power supply faceplate (or the corresponding
POWER OK LED on the craft interface). If this LED is on, the power source is good and the power supply is functional.
•
Check the display on the craft interface. The Junos OS constantly updates the screen with status information for each component. For more information about the display, see
“M320 Craft Interface Description” on page 15 .
NOTE: On the display and in the CLI, the power supplies are referred to as
PEM0 through PEM3, from top to bottom.
If a power supply is not functioning normally, perform the following steps to diagnose and correct the problem:
•
If the OUTPUT OK power supply LED is off, check the red alarm LED on the craft interface. The Junos OS monitors the system temperature, and if it exceeds a certain limit, the software triggers a red alarm, a condition that shuts down the power supplies.
•
If a red alarm condition occurs, check the display on the craft interface to determine the source of the problem.
NOTE: If the system temperature exceeds the threshold, the Junos OS shuts down all power supplies so that no status is displayed.
The Junos OS also can shut down one of the power supplies for other reasons. In this case, the remaining power supplies assume the load, and you can still view the system status through the CLI or display.
• If the OUTPUT OK power supply LED is off and no red alarm condition exists, check that the circuit breaker on a DC power supply or the power switch on an AC power supply is switched to the on position (|).
• Verify that the source circuit breaker has the proper current rating. Each power supply must be connected to a separate source circuit breaker.
•
Verify that the power cord (AC) or power cables (DC) from the power source to the router are not damaged. If the insulation is cracked or broken, immediately replace the cord or cable. See
“Replacing an M320 AC Power Supply Cord” on page 254
or “Replacing an M320 DC Power Supply Cable” on page 255 .
•
Connect the power supply to a different power source with a new power cord or power cables. If the power supply OUTPUT OK LED still does not light, the power supply is the source of the problem. Replace the power supply with a spare, as described in
“Replacing an M320 AC Power Supply” on page 247
or
292 Copyright © 2015, Juniper Networks, Inc.
Chapter 32: Troubleshooting Components
•
If the OUTPUT OK LED on the installed spare lights, the replaced power supply is faulty, and you should return it for replacement.
• If you cannot determine the cause of the problem or need additional assistance, see
“Contacting Customer Support” on page 297 .
Related
Documentation
•
M320 Power System Description on page 73
•
General Electrical Safety Warnings for Juniper Networks Devices on page 341
Copyright © 2015, Juniper Networks, Inc.
293
M320 Multiservice Edge Router Hardware Guide
294 Copyright © 2015, Juniper Networks, Inc.
PART 7
Contacting Customer Support and
Returning the Chassis or Components
•
Contacting Customer Support on page 297
•
Locating Component Serial Numbers on page 299
•
Packing and Returning Components on page 307
Copyright © 2015, Juniper Networks, Inc.
295
M320 Multiservice Edge Router Hardware Guide
296 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 33
Contacting Customer Support
•
Contacting Customer Support on page 297
Contacting Customer Support
You can contact Juniper Networks Technical Assistance Center (JTAC) 24 hours a day,
7 days a week in one of the following ways:
• On the Web, using the Case Manager link at: http://www.juniper.net/support/
• By telephone:
From the US and Canada: 1-888-314-JTAC
From all other locations: 1-408-745-9500
If contacting JTAC by phone, enter your 11-digit case number followed by the # key if this is an existing case, or press the * key to be routed to the next available support engineer.
When requesting support from JTAC by telephone, be prepared to provide the following information:
•
Your existing case number, if you have one
• Details of the failure or problem
• Type of activity being performed on the platform when the problem occurred
•
Configuration data using one or more of the show commands
Related
Documentation
•
Returning a Hardware Component to Juniper Networks, Inc. on page 307
Copyright © 2015, Juniper Networks, Inc.
297
M320 Multiservice Edge Router Hardware Guide
298 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 34
Locating Component Serial Numbers
•
Locating M320 Component Serial Numbers Using the CLI on page 299
•
Locating the M320 Chassis Serial Number Label on page 300
•
Locating the M320 CIP Serial Number Label on page 300
•
Locating the M320 Craft Interface Serial Number Label on page 301
•
Locating the M320 Routing Engine Serial Number Label on page 301
•
Locating the M320 CB Serial Number Label on page 302
•
Locating the M320 FPC Serial Number Label on page 302
•
Locating the M320 PIC Serial Number Label on page 303
•
Locating the M320 Power Supply Serial Number Labels on page 304
•
Locating the M320 SIB Serial Number Label on page 306
Locating M320 Component Serial Numbers Using the CLI
Before contacting Juniper Networks, Inc. to request a Return Materials Authorization
(RMA), you must find the serial number on the router or component. To list all of the router components and their serial numbers, enter the following command-line interface
(CLI) command: user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis 19206 M320
Midplane REV 01 710-009120 RA1277
FPM GBUS REV 02 710-005928 HL7863
FPM Display REV 01 710-009351 HP8406
CIP REV 02 710-005926 BE1813
PEM 0 Rev 01 740-009148 0000005
PEM 1 Rev 01 740-009148 0000006
PEM 2 Rev 01 740-009148 0000007
PEM 3 Rev 01 740-009148 0000008
Routing Engine 0 REV 01 740-008883 212047100102 RE-4.0
Routing Engine 1 REV 01 740-008883 212047100107 RE-4.0
CB 0 REV 01 710-009115 HK0109
CB 1 REV 01 710-009115 HK0110
FPC 0 REV 01 710-008994 HP1418 FPC Type 1
CPU REV 01 710-009141 HL7870
PIC 0 REV 04 750-001894 HE5409 1x G/E, 1000 BASE-SX
PIC 1 REV 01 750-010240 CB5373 1x G/E SFP, 1000 BASE
SFP 0 REV 01 740-007326 P11EAW5 SFP-SX
Copyright © 2015, Juniper Networks, Inc.
299
M320 Multiservice Edge Router Hardware Guide
PIC 3 REV 02 750-002332 AG1661 1x COC12, SMIR
SIB 0 REV 03 750-004762 HL9370 SIB-I-M
SIB 1 REV 03 710-009184 HP8459 SIB-I-M
Most components also have a small rectangular serial number ID label (see
) attached to the component body.
Figure 119: Serial Number ID Label
Related
Documentation
•
M320 Chassis Description on page 7
•
M320 Component Redundancy on page 4
•
Removing M320 Components from the Chassis on page 143
Locating the M320 Chassis Serial Number Label
The chassis serial number is located on the side of the chassis (see
).
Figure 120: M320 Chassis Serial Number Label
Related
Documentation
•
M320 Chassis Description on page 7
•
M320 Chassis and Interface Alarm Messages on page 285
Locating the M320 CIP Serial Number Label
The serial number label is located at the middle of the left side of the CIP (see
300 Copyright © 2015, Juniper Networks, Inc.
Figure 121: CIP Serial Number Label
Chapter 34: Locating Component Serial Numbers
Related
Documentation
•
M320 Chassis Description on page 7
•
M320 Connector Interface Panel (CIP) Description on page 13
•
Replacing the M320 CIP on page 189
Locating the M320 Craft Interface Serial Number Label
The serial number is located on the back of the craft interface panel, behind the alarm
LEDs (see
Figure 122: Craft Interface Serial Number Label
Related
Documentation
•
M320 Craft Interface Description on page 15
•
Replacing an M320 Craft Interface on page 197
Locating the M320 Routing Engine Serial Number Label
The serial number label is located on the right side of the top of the Routing Engine (see
).
Copyright © 2015, Juniper Networks, Inc.
301
M320 Multiservice Edge Router Hardware Guide
Figure 123: Routing Engine Serial Number Label
Related
Documentation
•
M320 Routing Engine Description on page 24
•
Replacing an M320 Routing Engine on page 216
Locating the M320 CB Serial Number Label
The serial number is located on the right side of the top of the CB (see
Figure 124: CB Serial Number Label
Related
Documentation
•
M320 Control Board (CB) Description on page 45
•
Replacing an M320 Control Board on page 223
Locating the M320 FPC Serial Number Label
The serial number label is located on the center of the right side of the FPC3 (see
Figure 125 on page 303 ). On an FPC2, the serial number label is located near the top PIC
slot.
302 Copyright © 2015, Juniper Networks, Inc.
Figure 125: FPC Serial Number Label
Chapter 34: Locating Component Serial Numbers
Related
Documentation
•
M320 Flexible PIC Concentrator (FPC) Description on page 49
•
Maintaining M320 FPCs on page 270
•
Troubleshooting the M320 FPCs on page 289
•
Replacing an M320 FPC on page 227
Locating the M320 PIC Serial Number Label
The serial number label is located on the right side of the PIC (see
when the PIC is vertically oriented (as it would be installed in the router). The exact location may be slightly different on different PICs, depending on the placement of components on the PIC board.
Copyright © 2015, Juniper Networks, Inc.
303
M320 Multiservice Edge Router Hardware Guide
Figure 126: PIC Serial Number Label
Related
Documentation
•
M320 PIC Description on page 54
•
Maintaining M320 PICs and PIC Cables on page 276
•
Troubleshooting the M320 PICs on page 291
•
Replacing an M320 PIC on page 233
Locating the M320 Power Supply Serial Number Labels
The serial number label is located on the AC power supply faceplate under the circuit breaker switch (see
The serial number label is located on the DC power supply faceplate under the circuit breaker switch (see
).
304 Copyright © 2015, Juniper Networks, Inc.
Chapter 34: Locating Component Serial Numbers
Figure 127: AC Power Supply Serial Number Label
Figure 128: DC Power Supply Serial Number Label
Related
Documentation
•
M320 Power System Description on page 73
•
Maintaining the M320 Power Supplies on page 278
•
Troubleshooting the M320 Power System on page 292
•
Replacing an M320 AC Power Supply on page 247
•
Replacing an M320 DC Power Supply on page 250
Copyright © 2015, Juniper Networks, Inc.
305
M320 Multiservice Edge Router Hardware Guide
Locating the M320 SIB Serial Number Label
The serial number label is located on the right side of the top of the SIB (see
Figure 129: SIB Serial Number Label
Related
Documentation
•
M320 SIB Description on page 79
•
Maintaining the M320 SIBs on page 279
•
Replacing an M320 SIB on page 259
306 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 35
Packing and Returning Components
•
Returning a Hardware Component to Juniper Networks, Inc. on page 307
•
Tools and Parts Required to Remove Components From an M320 Router on page 308
•
Packing the M320 Router for Shipment on page 308
•
Packing M320 Router Components for Shipment on page 310
Returning a Hardware Component to Juniper Networks, Inc.
If a problem cannot be resolved by the JTAC technician, a Return Materials Authorization
(RMA) is issued. This number is used to track the returned material at the factory and to return repaired or new components to the customer as needed.
NOTE: Do not return any component to Juniper Networks, Inc. unless you have first obtained an RMA number. Juniper Networks, Inc. reserves the right to refuse shipments that do not have an RMA. Refused shipments will be returned to the customer by collect freight.
For more information about return and repair policies, see the customer support Web page at http://www.juniper.net/support/guidelines.html
.
For product problems or technical support issues, contact the Juniper Networks Technical
Assistance Center (JTAC) using the Case Manager link at http://www.juniper.net/support/ or at 1-888-314-JTAC (within the United States) or 1-408-745-9500 (from outside the
United States).
To return a hardware component:
1.
Determine the part number and serial number of the component.
2.
Obtain an RMA number from the Juniper Networks Technical Assistance Center (JTAC).
You can send e-mail or telephone as described above.
3.
Provide the following information in your e-mail message or during the telephone call:
• Part number and serial number of component
• Your name, organization name, telephone number, and fax number
•
Description of the failure
Copyright © 2015, Juniper Networks, Inc.
307
M320 Multiservice Edge Router Hardware Guide
4.
The support representative validates your request and issues an RMA number for return of the component.
5.
Pack the component for shipment.
Related
Documentation
•
Contacting Customer Support on page 297
•
Guidelines for Packing Router Components for Shipment
Tools and Parts Required to Remove Components From an M320 Router
To remove components from the router or the router from a rack, you need the following tools and parts:
•
2.5-mm flat-blade (–) screwdriver, for detaching alarm relay terminal block
• 7/16-in. (11 mm) nut driver
• Blank panels to cover empty slots
•
Electrostatic bag or antistatic mat, for each component
•
Electrostatic discharge (ESD) grounding wrist strap
• Flat-blade (–) screwdriver
• Mechanical lift, if available
•
Phillips (+) screwdrivers, numbers 1 and 2
•
Rubber safety cap for fiber-optic interfaces or cable
• Wire cutters
Related
Documentation
•
Contacting Customer Support on page 297
•
M320 Chassis and Interface Alarm Messages on page 285
Packing the M320 Router for Shipment
To pack the router for shipment:
1.
Retrieve the shipping crate and packing materials in which the router was originally shipped. If you do not have these materials, contact your Juniper Networks representative about approved packaging materials.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
On the console or other management device connected to the master Routing Engine, enter CLI operational mode and issue the following command to shut down the router software. (If two Routing Engines are installed, also issue the command on the backup
Routing Engine.) user@host> request system halt
308 Copyright © 2015, Juniper Networks, Inc.
Chapter 35: Packing and Returning Components
Wait until a message appears on the console confirming that the operating system has halted.
For more information about the command, see the CLI Explorer .
NOTE: The SIB might continue forwarding traffic for approximately 5 minutes after the request system halt command has been issued.
4.
Shut down power to the router by pressing the power switch for all power supplies to the off (O) position. On both AC and DC power supplies, the switch is located on the power supply faceplate.
5.
Disconnect power from the router. For instructions, see
or
“Replacing an M320 DC Power Supply Cable” on page 255 .
6.
Remove the cables that connect to all external devices. For instructions, see
“Removing an M320 PIC Cable” on page 238 ,
“Removing an M320 Console or Auxiliary Cable” on page 194 ,
“Replacing the M320 Alarm Relay Wires” on page 192 , and “Replacing an
M320 Management Ethernet Cable” on page 192 .
7.
Remove all Field Replaceable Units (FRUs) from the router.
See
“Removing M320 Components from the Chassis” on page 143 .
8.
Remove the router from the rack:
•
If you are using a mechanical lift, place the lift platform under the router, unscrew and remove the mounting screws from the rack, and move the router to the shipping crate.
• If you are not using a mechanical lift and the router weight is fully supported by a shelf or another router, unscrew and remove the mounting screws from the rack.
Three people can then lift the router and move it to the shipping crate.
• If you are not using a mechanical lift and the router weight is not fully supported by a shelf or another router, three people should grasp the router while a fourth person unscrews and removes the mounting screws from the rack. The three lifters can then move the router to the shipping crate.
9.
Place the router in the shipping crate or onto the pallet. If on a pallet, bolt the router to the pallet.
10.
Cover the router with an ESD bag and place the packing foam on top of and around the router.
11.
Replace the accessory box on top of the packing foam.
12.
Securely tape the box closed or place the crate cover over the router.
13.
Write the RMA number on the exterior of the box to ensure proper tracking.
Related
Documentation
•
M320 Router Description on page 3
•
Returning a Hardware Component to Juniper Networks, Inc. on page 307
•
Contacting Customer Support on page 297
Copyright © 2015, Juniper Networks, Inc.
309
M320 Multiservice Edge Router Hardware Guide
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Packing M320 Router Components for Shipment
To pack and ship individual components:
•
When you return components, make sure they are adequately protected with packing materials and packed so that the pieces are prevented from moving around inside the carton.
• Use the original shipping materials if they are available.
•
Place individual components in electrostatic bags.
•
Write the RMA number on the exterior of the box to ensure proper tracking.
CAUTION: Do not stack any of the router components.
Related
Documentation
•
M320 Chassis and Interface Alarm Messages on page 285
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
•
Contacting Customer Support on page 297
310 Copyright © 2015, Juniper Networks, Inc.
PART 8
Safety and Compliance Information
•
General Safety Guidelines and Warnings on page 313
•
Fire Safety Requirements on page 321
•
Installation Safety Guidelines and Warnings on page 323
•
Laser and LED Safety Guidelines and Warnings on page 331
•
Maintenance and Operational Safety Guidelines and Warnings on page 335
•
Electrical Safety Guidelines and Warnings on page 341
•
Agency Approvals and Compliance Statements on page 351
Copyright © 2015, Juniper Networks, Inc.
311
M320 Multiservice Edge Router Hardware Guide
312 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 36
General Safety Guidelines and Warnings
•
Definition of Safety Warning Levels on page 313
•
General Safety Guidelines for Juniper Networks Devices on page 315
•
General Safety Warnings for Juniper Networks Devices on page 316
•
M320 In Case of an Electrical Accident on page 318
•
Preventing Electrostatic Discharge Damage to an M320 Router on page 318
Definition of Safety Warning Levels
The documentation uses the following levels of safety warnings:
NOTE: You might find this information helpful in a particular situation, or might otherwise overlook it.
CAUTION: You must observe the specified guidelines to avoid minor injury or discomfort to you, or severe damage to the hardware device.
WARNING: This symbol alerts you to the risk of personal injury from a laser.
WARNING: This symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen.
Copyright © 2015, Juniper Networks, Inc.
313
M320 Multiservice Edge Router Hardware Guide
314
Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista.
Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels.
Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents.
Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer
Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der
Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen
Stromkreisen verbundenen Gefahren und der Standardpraktiken zur
Vermeidung von Unfällen bewußt.
Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti.
Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker.
Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes.
¡Atención! Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes.
Varning! Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador.
Related
Documentation
•
General Safety Warnings for Juniper Networks Devices on page 316
•
Installation Safety Warnings for Juniper Networks Devices on page 324
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 335
•
General Electrical Safety Warnings for Juniper Networks Devices on page 341
Copyright © 2015, Juniper Networks, Inc.
Chapter 36: General Safety Guidelines and Warnings
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 347
General Safety Guidelines for Juniper Networks Devices
The following guidelines help ensure your safety and protect the hardware equipment from damage. The list of guidelines might not address all potentially hazardous situations in your working environment, so be alert and exercise good judgment at all times.
• Perform only the procedures explicitly described in this documentation. Make sure that only authorized service personnel perform other system services.
•
Keep the area around the chassis clear and free from dust before, during, and after installation.
• Keep tools away from areas where people could trip over them while walking.
• Do not wear loose clothing or jewelry, such as rings, bracelets, or chains, which could become caught in the chassis.
•
Wear safety glasses if you are working under any conditions that could be hazardous to your eyes.
• Do not perform any actions that create a potential hazard to people or make the equipment unsafe.
•
Never attempt to lift an object that is too heavy for one person to handle.
• Never install or manipulate wiring during electrical storms.
• Never install electrical jacks in wet locations unless the jacks are specifically designed for wet environments.
•
Operate the hardware equipment only when the chassis is properly grounded.
• Do not open or remove chassis covers or sheet metal parts unless instructions are provided in this documentation. Such an action could cause severe electrical shock.
•
Do not push or force any objects through any opening in the chassis frame. Such an action could result in electrical shock or fire.
• Avoid spilling liquid onto the chassis or onto any hardware component. Such an action could cause electrical shock or damage the hardware equipment.
•
Avoid touching uninsulated electrical wires or terminals that have not been disconnected from their power source. Such an action could cause electrical shock.
• Some parts of the router might become hot. The following label provides the warning of the hot surfaces on the router:
Related
Documentation
•
General Safety Warnings for Juniper Networks Devices on page 316
Copyright © 2015, Juniper Networks, Inc.
315
M320 Multiservice Edge Router Hardware Guide
General Safety Warnings for Juniper Networks Devices
•
Qualified Personnel Warning on page 316
•
Restricted Access Area Warning on page 316
Qualified Personnel Warning
WARNING: Only trained and qualified personnel should install or replace the hardware equipment.
Waarschuwing Installatie en reparaties mogen uitsluitend door getraind en bevoegd personeel uitgevoerd worden.
Varoitus Ainoastaan koulutettu ja pätevä henkilökunta saa asentaa tai vaihtaa tämän laitteen.
Attention Tout installation ou remplacement de l'appareil doit être réalisé par du personnel qualifié et compétent.
Warnung Gerät nur von geschultem, qualifiziertem Personal installieren oder auswechseln lassen.
Avvertenza Solo personale addestrato e qualificato deve essere autorizzato ad installare o sostituire questo apparecchio.
Advarsel Kun kvalifisert personell med riktig opplæring bør montere eller bytte ut dette utstyret.
Aviso Este equipamento deverá ser instalado ou substituído apenas por pessoal devidamente treinado e qualificado.
¡Atención! Estos equipos deben ser instalados y reemplazados exclusivamente por personal técnico adecuadamente preparado y capacitado.
Varning! Denna utrustning ska endast installeras och bytas ut av utbildad och kvalificerad personal.
Restricted Access Area Warning
WARNING: The hardware equipment is intended for installation in restricted access areas. A restricted access area is an area to which access can be gained only by service personnel through the use of a special tool, lock and key, or other means of security, and which is controlled by the authority responsible for the location.
Waarschuwing Dit toestel is bedoeld voor installatie op plaatsen met beperkte toegang. Een plaats met beperkte toegang is een plaats waar toegang slechts door servicepersoneel verkregen kan worden door middel van een speciaal
316 Copyright © 2015, Juniper Networks, Inc.
Chapter 36: General Safety Guidelines and Warnings
Copyright © 2015, Juniper Networks, Inc.
instrument, een slot en sleutel, of een ander veiligheidsmiddel, en welke beheerd wordt door de overheidsinstantie die verantwoordelijk is voor de locatie.
Varoitus Tämä laite on tarkoitettu asennettavaksi paikkaan, johon pääsy on rajoitettua. Paikka, johon pääsy on rajoitettua, tarkoittaa paikkaa, johon vain huoltohenkilöstö pääsee jonkin erikoistyökalun, lukkoon sopivan avaimen tai jonkin muun turvalaitteen avulla ja joka on paikasta vastuussa olevien toimivaltaisten henkilöiden valvoma.
Attention Cet appareil est à installer dans des zones d'accès réservé. Ces dernières sont des zones auxquelles seul le personnel de service peut accéder en utilisant un outil spécial, un mécanisme de verrouillage et une clé, ou tout autre moyen de sécurité. L'accès aux zones de sécurité est sous le contrôle de l'autorité responsable de l'emplacement.
Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem
Zutritt vorgesehen. Ein Bereich mit beschränktem Zutritt ist ein Bereich, zu dem nur Wartungspersonal mit einem Spezialwerkzeugs, Schloß und
Schlüssel oder anderer Sicherheitsvorkehrungen Zugang hat, und der von dem für die Anlage zuständigen Gremium kontrolliert wird.
Avvertenza Questa unità deve essere installata in un'area ad accesso limitato.
Un'area ad accesso limitato è un'area accessibile solo a personale di assistenza tramite un'attrezzo speciale, lucchetto, o altri dispositivi di sicurezza, ed è controllata dall'autorità responsabile della zona.
Advarsel Denne enheten er laget for installasjon i områder med begrenset adgang. Et område med begrenset adgang gir kun adgang til servicepersonale som bruker et spesielt verktøy, lås og nøkkel, eller en annen sikkerhetsanordning, og det kontrolleres av den autoriteten som er ansvarlig for området.
Aviso Esta unidade foi concebida para instalação em áreas de acesso restrito.
Uma área de acesso restrito é uma área à qual apenas tem acesso o pessoal de serviço autorizado, que possua uma ferramenta, chave e fechadura especial, ou qualquer outra forma de segurança. Esta área é controlada pela autoridade responsável pelo local.
¡Atención! Esta unidad ha sido diseñada para instalarse en áreas de acceso restringido. Área de acceso restringido significa un área a la que solamente tiene acceso el personal de servicio mediante la utilización de una herramienta especial, cerradura con llave, o algún otro medio de seguridad, y que está bajo el control de la autoridad responsable del local.
Varning! Denna enhet är avsedd för installation i områden med begränsat tillträde. Ett område med begränsat tillträde får endast tillträdas av servicepersonal med ett speciellt verktyg, lås och nyckel, eller annan säkerhetsanordning, och kontrolleras av den auktoritet som ansvarar för området.
317
M320 Multiservice Edge Router Hardware Guide
Related
Documentation
•
Installation Safety Warnings for Juniper Networks Devices on page 324
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 335
•
General Electrical Safety Warnings for Juniper Networks Devices on page 341
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 347
M320 In Case of an Electrical Accident
If an electrical accident results in an injury, take the following actions in this order:
1.
Use caution. Be aware of potentially hazardous conditions that could cause further injury.
2.
Disconnect power from the router.
3.
If possible, send another person to get medical aid. Otherwise, assess the condition of the victim, then call for help.
Related
Documentation
Preventing Electrostatic Discharge Damage to an M320 Router
Many router hardware components are sensitive to damage from static electricity. Some components can be impaired by voltages as low as 30 V. You can easily generate potentially damaging static voltages whenever you handle plastic or foam packing material or if you move components across plastic or carpets. Observe the following guidelines to minimize the potential for electrostatic discharge (ESD) damage, which can cause intermittent or complete component failures:
• Always use an ESD wrist strap or ankle strap, and make sure that it is in direct contact with your skin.
CAUTION: For safety, periodically check the resistance value of the ESD strap. The measurement should be in the range of 1 through 10 Mohms.
• When handling any component that is removed from the chassis, make sure the equipment end of your ESD strap is attached to one of the ESD points on the chassis.
•
Avoid contact between the component and your clothing. ESD voltages emitted from clothing can still damage components.
• When removing or installing a component, always place it component-side up on an antistatic surface, in an antistatic card rack, or in an electrostatic bag (see
) . If you are returning a component, place it in an electrostatic bag before packing it.
318 Copyright © 2015, Juniper Networks, Inc.
Chapter 36: General Safety Guidelines and Warnings
Figure 130: Placing a Component into an Electrostatic Bag
Related
Documentation
•
M320 Router Description on page 3
•
General Electrical Safety Warnings for Juniper Networks Devices on page 341
•
Installation Safety Warnings for Juniper Networks Devices on page 324
•
Contacting Customer Support on page 297
Copyright © 2015, Juniper Networks, Inc.
319
M320 Multiservice Edge Router Hardware Guide
320 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 37
Fire Safety Requirements
•
Fire Safety Requirements for Juniper Networks Devices on page 321
Fire Safety Requirements for Juniper Networks Devices
•
General Fire Safety Requirements on page 321
•
•
Fire Suppression Equipment on page 321
General Fire Safety Requirements
In the event of a fire emergency involving network devices, the safety of people is the primary concern. Establish procedures for protecting people in a fire emergency, provide safety training, and properly provision fire-control equipment and fire extinguishers.
In addition, establish procedures to protect your equipment in a fire emergency. Juniper
Networks products should be installed in an environment suitable for electronic equipment. We recommend that fire suppression equipment be available in the event of a fire in the vicinity of the equipment, and that you observe all local fire, safety, and electrical codes and ordinances when installing and operating your equipment.
Fire Suppression
In the event of an electrical hazard or an electrical fire, first turn power off to the equipment at the source. Then use a Type C fire extinguisher, which uses noncorrosive fire retardants, to extinguish the fire.
Fire Suppression Equipment
Type C fire extinguishers, which use noncorrosive fire retardants such as carbon dioxide
(CO
2
) and Halotron, are most effective for suppressing electrical fires. Type C fire extinguishers displace the oxygen from the point of combustion to eliminate the fire. For extinguishing fire on or around equipment that draws air from the environment for cooling, use this type of inert oxygen displacement extinguisher instead of an extinguisher that leave residues on equipment.
Do not use multipurpose Type ABC chemical fire extinguishers (dry chemical fire extinguishers) near Juniper Networks devices. The primary ingredient in these fire extinguishers is monoammonium phosphate, which is very sticky and difficult to clean.
Copyright © 2015, Juniper Networks, Inc.
321
M320 Multiservice Edge Router Hardware Guide
In addition, in minute amounts of moisture, monoammonium phosphate can become highly corrosive and corrodes most metals.
Any equipment in a room in which a chemical fire extinguisher has been discharged is subject to premature failure and unreliable operation. The equipment is considered to be irreparably damaged.
NOTE: To keep warranties effective, do not use a dry chemical fire extinguisher to control a fire at or near a Juniper Networks device. If a dry chemical fire extinguisher is used, the unit is no longer eligible for coverage under a service agreement.
We recommend that you dispose of any irreparably damaged equipment in an environmentally responsible manner.
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 315
•
General Safety Warnings for Juniper Networks Devices on page 316
•
General Electrical Safety Warnings for Juniper Networks Devices on page 341
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 347
322 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 38
Installation Safety Guidelines and
Warnings
•
M320 Installation Safety Guidelines on page 323
•
Installation Safety Warnings for Juniper Networks Devices on page 324
M320 Installation Safety Guidelines
•
M320 General Installation Safety Guidelines on page 323
•
M320 Chassis Lifting Guidelines on page 323
M320 General Installation Safety Guidelines
Before installing the router, verify that the intended site meets the specified power, environmental, and clearance requirements.
•
M320 Clearance Requirements on page 91
•
Rack Requirements for the M320 Router on page 87
•
M320 Environmental Specifications on page 93
•
M320 DC Power Distribution on page 109
•
M320 Power Requirements on page 96
M320 Chassis Lifting Guidelines
The weight of a fully configured M320 router is about 439 lb (199.6 kg). Observe the following guidelines for lifting and moving the router:
• Do not attempt to lift a fully configured router by yourself. Using a mechanical lift to maneuver the router into a rack is recommended. If a lift cannot be used, a minimum of three people are required to lift the router, and you must remove components from the chassis before lifting.
• Before lifting or moving the router, disconnect all external cables.
• As when lifting any heavy object, lift most of the weight with your legs rather than your back. Keep your knees bent and your back relatively straight and avoid twisting your body as you lift. Balance the load evenly and be sure that your footing is solid.
Copyright © 2015, Juniper Networks, Inc.
323
M320 Multiservice Edge Router Hardware Guide
Related
Documentation
•
Installation Safety Warnings for Juniper Networks Devices on page 324
Installation Safety Warnings for Juniper Networks Devices
Observe the following warnings before and during hardware equipment installation:
•
Intra-Building Ports Warning on page 324
•
Installation Instructions Warning on page 324
•
Rack-Mounting Requirements and Warnings on page 325
•
Intra-Building Ports Warning
WARNING: The intra-building ports of the equipment or subassembly are suitable for connection to intra-building or unexposed wiring or cabling only.
The intra-building ports of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or its wiring.
These interfaces are designed for use as intra-building interfaces only (Type
2 or Type 4 ports as described in GR-1089) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.
Installation Instructions Warning
WARNING: Read the installation instructions before you connect the hardware equipment to a power source.
Waarschuwing Raadpleeg de installatie-aanwijzingen voordat u het systeem met de voeding verbindt.
Varoitus Lue asennusohjeet ennen järjestelmän yhdistämistä virtalähteeseen.
Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation.
Warnung Lesen Sie die Installationsanweisungen, bevor Sie das System an die Stromquelle anschließen.
Avvertenza Consultare le istruzioni di installazione prima di collegare il sistema all'alimentatore.
Advarsel Les installasjonsinstruksjonene før systemet kobles til strømkilden.
Aviso Leia as instruções de instalação antes de ligar o sistema à sua fonte de energia.
324 Copyright © 2015, Juniper Networks, Inc.
Chapter 38: Installation Safety Guidelines and Warnings
¡Atención! Ver las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
Varning! Läs installationsanvisningarna innan du kopplar systemet till dess strömförsörjningsenhet.
Rack-Mounting Requirements and Warnings
Ensure that the equipment rack into which the chassis is installed is evenly and securely supported, to avoid the hazardous condition that could result from uneven mechanical loading.
WARNING: To prevent bodily injury when mounting or servicing the chassis in a rack, take the following precautions to ensure that the system remains stable. The following directives help maintain your safety:
• The chassis must be installed into a rack that is secured to the building structure.
•
When mounting the chassis in a partially filled rack, load the rack from the bottom to the top, with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before mounting the chassis in the rack or servicing the hardware equipment.
Waarschuwing Om lichamelijk letsel te voorkomen wanneer u dit toestel in een rek monteert of het daar een servicebeurt geeft, moet u speciale voorzorgsmaatregelen nemen om ervoor te zorgen dat het toestel stabiel blijft. De onderstaande richtlijnen worden verstrekt om uw veiligheid te verzekeren:
•
De router moet in een stellage worden geïnstalleerd die aan een bouwsel is verankerd.
• Dit toestel dient onderaan in het rek gemonteerd te worden als het toestel het enige in het rek is.
•
Wanneer u dit toestel in een gedeeltelijk gevuld rek monteert, dient u het rek van onderen naar boven te laden met het zwaarste onderdeel onderaan in het rek.
• Als het rek voorzien is van stabiliseringshulpmiddelen, dient u de stabilisatoren te monteren voordat u het toestel in het rek monteert of het daar een servicebeurt geeft.
Varoitus Kun laite asetetaan telineeseen tai huolletaan sen ollessa telineessä, on noudatettava erityisiä varotoimia järjestelmän vakavuuden säilyttämiseksi, jotta vältytään loukkaantumiselta. Noudata seuraavia turvallisuusohjeita:
Copyright © 2015, Juniper Networks, Inc.
325
M320 Multiservice Edge Router Hardware Guide
• Router on asennettava telineeseen, joka on kiinnitetty rakennukseen.
• Jos telineessä ei ole muita laitteita, aseta laite telineen alaosaan.
•
Jos laite asetetaan osaksi täytettyyn telineeseen, aloita kuormittaminen sen alaosasta kaikkein raskaimmalla esineellä ja siirry sitten sen yläosaan.
• Jos telinettä varten on vakaimet, asenna ne ennen laitteen asettamista telineeseen tai sen huoltamista siinä.
Attention Pour éviter toute blessure corporelle pendant les opérations de montage ou de réparation de cette unité en casier, il convient de prendre des précautions spéciales afin de maintenir la stabilité du système. Les directives ci-dessous sont destinées à assurer la protection du personnel:
• Le rack sur lequel est monté le router doit être fixé à la structure du bâtiment.
•
Si cette unité constitue la seule unité montée en casier, elle doit être placée dans le bas.
• Si cette unité est montée dans un casier partiellement rempli, charger le casier de bas en haut en plaçant l'élément le plus lourd dans le bas.
•
Si le casier est équipé de dispositifs stabilisateurs, installer les stabilisateurs avant de monter ou de réparer l'unité en casier.
Warnung Zur Vermeidung von Körperverletzung beim Anbringen oder Warten dieser Einheit in einem Gestell müssen Sie besondere Vorkehrungen treffen, um sicherzustellen, daß das System stabil bleibt. Die folgenden Richtlinien sollen zur Gewährleistung Ihrer Sicherheit dienen:
•
Der router muß in einem Gestell installiert werden, das in der
Gebäudestruktur verankert ist.
• Wenn diese Einheit die einzige im Gestell ist, sollte sie unten im Gestell angebracht werden.
•
Bei Anbringung dieser Einheit in einem zum Teil gefüllten Gestell ist das
Gestell von unten nach oben zu laden, wobei das schwerste Bauteil unten im Gestell anzubringen ist.
• Wird das Gestell mit Stabilisierungszubehör geliefert, sind zuerst die
Stabilisatoren zu installieren, bevor Sie die Einheit im Gestell anbringen oder sie warten.
Avvertenza Per evitare infortuni fisici durante il montaggio o la manutenzione di questa unità in un supporto, occorre osservare speciali precauzioni per garantire che il sistema rimanga stabile. Le seguenti direttive vengono fornite per garantire la sicurezza personale:
326 Copyright © 2015, Juniper Networks, Inc.
Copyright © 2015, Juniper Networks, Inc.
Chapter 38: Installation Safety Guidelines and Warnings
• Il router deve essere installato in un telaio, il quale deve essere fissato alla struttura dell'edificio.
•
Questa unità deve venire montata sul fondo del supporto, se si tratta dell'unica unità da montare nel supporto.
• Quando questa unità viene montata in un supporto parzialmente pieno, caricare il supporto dal basso all'alto, con il componente più pesante sistemato sul fondo del supporto.
•
Se il supporto è dotato di dispositivi stabilizzanti, installare tali dispositivi prima di montare o di procedere alla manutenzione dell'unità nel supporto.
Advarsel Unngå fysiske skader under montering eller reparasjonsarbeid på denne enheten når den befinner seg i et kabinett. Vær nøye med at systemet er stabilt. Følgende retningslinjer er gitt for å verne om sikkerheten:
•
Router må installeres i et stativ som er forankret til bygningsstrukturen.
•
Denne enheten bør monteres nederst i kabinettet hvis dette er den eneste enheten i kabinettet.
• Ved montering av denne enheten i et kabinett som er delvis fylt, skal kabinettet lastes fra bunnen og opp med den tyngste komponenten nederst i kabinettet.
• Hvis kabinettet er utstyrt med stabiliseringsutstyr, skal stabilisatorene installeres før montering eller utføring av reparasjonsarbeid på enheten i kabinettet.
Aviso Para se prevenir contra danos corporais ao montar ou reparar esta unidade numa estante, deverá tomar precauções especiais para se certificar de que o sistema possui um suporte estável. As seguintes directrizes ajudá-lo-ão a efectuar o seu trabalho com segurança:
• O router deverá ser instalado numa prateleira fixa à estrutura do edificio.
•
Esta unidade deverá ser montada na parte inferior da estante, caso seja esta a única unidade a ser montada.
• Ao montar esta unidade numa estante parcialmente ocupada, coloque os itens mais pesados na parte inferior da estante, arrumando-os de baixo para cima.
•
Se a estante possuir um dispositivo de estabilização, instale-o antes de montar ou reparar a unidade.
¡Atención! Para evitar lesiones durante el montaje de este equipo sobre un bastidor, o posteriormente durante su mantenimiento, se debe poner mucho cuidado en que el sistema quede bien estable. Para garantizar su seguridad, proceda según las siguientes instrucciones:
327
M320 Multiservice Edge Router Hardware Guide
Ramp Warning
328
• El router debe instalarse en un bastidor fijado a la estructura del edificio.
• Colocar el equipo en la parte inferior del bastidor, cuando sea la única unidad en el mismo.
•
Cuando este equipo se vaya a instalar en un bastidor parcialmente ocupado, comenzar la instalación desde la parte inferior hacia la superior colocando el equipo más pesado en la parte inferior.
•
Si el bastidor dispone de dispositivos estabilizadores, instalar éstos antes de montar o proceder al mantenimiento del equipo instalado en el bastidor.
Varning! För att undvika kroppsskada när du installerar eller utför underhållsarbete på denna enhet på en ställning måste du vidta särskilda försiktighetsåtgärder för att försäkra dig om att systemet står stadigt. Följande riktlinjer ges för att trygga din säkerhet:
•
Router måste installeras i en ställning som är förankrad i byggnadens struktur.
• Om denna enhet är den enda enheten på ställningen skall den installeras längst ned på ställningen.
•
Om denna enhet installeras på en delvis fylld ställning skall ställningen fyllas nedifrån och upp, med de tyngsta enheterna längst ned på ställningen.
• Om ställningen är försedd med stabiliseringsdon skall dessa monteras fast innan enheten installeras eller underhålls på ställningen.
WARNING: When installing the hardware equipment, do not use a ramp inclined at more than 10 degrees.
Waarschuwing Gebruik een oprijplaat niet onder een hoek van meer dan 10 graden.
Varoitus Älä käytä sellaista kaltevaa pintaa, jonka kaltevuus ylittää 10 astetta.
Attention Ne pas utiliser une rampe dont l'inclinaison est supérieure à 10 degrés.
Warnung Keine Rampen mit einer Neigung von mehr als 10 Grad verwenden.
Avvertenza Non usare una rampa con pendenza superiore a 10 gradi.
Advarsel Bruk aldri en rampe som heller mer enn 10 grader.
Aviso Não utilize uma rampa com uma inclinação superior a 10 graus.
¡Atención! No usar una rampa inclinada más de 10 grados
Copyright © 2015, Juniper Networks, Inc.
Chapter 38: Installation Safety Guidelines and Warnings
Varning! Använd inte ramp med en lutning på mer än 10 grader.
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 315
•
General Safety Warnings for Juniper Networks Devices on page 316
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 335
Copyright © 2015, Juniper Networks, Inc.
329
M320 Multiservice Edge Router Hardware Guide
330 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 39
Laser and LED Safety Guidelines and
Warnings
•
M320 General Laser Safety Guidelines on page 331
•
Laser Safety Warnings for Juniper Networks Devices on page 331
M320 General Laser Safety Guidelines
Devices with single-mode optical interfaces are equipped with laser transmitters, which are considered a Class 1 Laser Product by the U.S. Food and Drug Administration, and are evaluated as a Class 1 Laser Product according to EN 60825–1 +A11 +A2 requirements.
When working around devices with optical interfaces, observe the following safety guidelines to prevent eye injury:
•
Do not look into unterminated ports or at fibers that connect to unknown sources.
•
Do not examine unterminated optical ports with optical instruments.
• Avoid direct exposure to the beam.
WARNING: Unterminated optical connectors can emit invisible laser radiation. The lens in the human eye focuses all the laser power on the retina, so focusing the eye directly on a laser source—even a low-power laser—could permanently damage the eye.
Related
Documentation
•
M320 Router Description on page 3
•
M320 Site Preparation Checklist Requirements on page 85
•
Laser Safety Warnings for Juniper Networks Devices on page 331
Laser Safety Warnings for Juniper Networks Devices
•
Class 1 Laser Product Warning on page 332
•
Class 1 LED Product Warning on page 332
Copyright © 2015, Juniper Networks, Inc.
331
M320 Multiservice Edge Router Hardware Guide
•
Laser Beam Warning on page 333
•
Radiation from Open Port Apertures Warning on page 333
Class 1 Laser Product Warning
WARNING: Class 1 laser product.
Waarschuwing Klasse-1 laser produkt.
Varoitus Luokan 1 lasertuote.
Attention Produit laser de classe I.
Warnung Laserprodukt der Klasse 1.
Avvertenza Prodotto laser di Classe 1.
Advarsel Laserprodukt av klasse 1.
Aviso Produto laser de classe 1.
¡Atención! Producto láser Clase I.
Varning! Laserprodukt av klass 1.
Class 1 LED Product Warning
WARNING: Class 1 LED product.
Waarschuwing Klasse 1 LED-product.
Varoitus Luokan 1 valodiodituote.
Attention Alarme de produit LED Class I.
Warnung Class 1 LED-Produktwarnung.
Avvertenza Avvertenza prodotto LED di Classe 1.
Advarsel LED-produkt i klasse 1.
Aviso Produto de classe 1 com LED.
¡Atención! Aviso sobre producto LED de Clase 1.
Varning! Lysdiodprodukt av klass 1.
332 Copyright © 2015, Juniper Networks, Inc.
Chapter 39: Laser and LED Safety Guidelines and Warnings
Laser Beam Warning
WARNING: Do not stare into the laser beam or view it directly with optical instruments.
Waarschuwing Niet in de straal staren of hem rechtstreeks bekijken met optische instrumenten.
Varoitus Älä katso säteeseen äläkä tarkastele sitä suoraan optisen laitteen avulla.
Attention Ne pas fixer le faisceau des yeux, ni l'observer directement à l'aide d'instruments optiques.
Warnung Nicht direkt in den Strahl blicken und ihn nicht direkt mit optischen
Geräten prüfen.
Avvertenza Non fissare il raggio con gli occhi né usare strumenti ottici per osservarlo direttamente.
Advarsel Stirr eller se ikke direkte p strlen med optiske instrumenter.
Aviso Não olhe fixamente para o raio, nem olhe para ele directamente com instrumentos ópticos.
¡Atención! No mirar fijamente el haz ni observarlo directamente con instrumentos ópticos.
Varning! Rikta inte blicken in mot strålen och titta inte direkt på den genom optiska instrument.
Radiation from Open Port Apertures Warning
WARNING: Because invisible radiation might be emitted from the aperture of the port when no fiber cable is connected, avoid exposure to radiation and do not stare into open apertures.
Waarschuwing Aangezien onzichtbare straling vanuit de opening van de poort kan komen als er geen fiberkabel aangesloten is, dient blootstelling aan straling en het kijken in open openingen vermeden te worden.
Varoitus Koska portin aukosta voi emittoitua näkymätöntä säteilyä, kun kuitukaapelia ei ole kytkettynä, vältä säteilylle altistumista äläkä katso avoimiin aukkoihin.
Attention Des radiations invisibles à l'il nu pouvant traverser l'ouverture du port lorsqu'aucun câble en fibre optique n'y est connecté, il est recommandé de ne pas regarder fixement l'intérieur de ces ouvertures.
Copyright © 2015, Juniper Networks, Inc.
333
M320 Multiservice Edge Router Hardware Guide
Warnung Aus der Port-Öffnung können unsichtbare Strahlen emittieren, wenn kein Glasfaserkabel angeschlossen ist. Vermeiden Sie es, sich den
Strahlungen auszusetzen, und starren Sie nicht in die Öffnungen!
Avvertenza Quando i cavi in fibra non sono inseriti, radiazioni invisibili possono essere emesse attraverso l'apertura della porta. Evitate di esporvi alle radiazioni e non guardate direttamente nelle aperture.
Advarsel Unngå utsettelse for stråling, og stirr ikke inn i åpninger som er åpne, fordi usynlig stråling kan emiteres fra portens åpning når det ikke er tilkoblet en fiberkabel.
Aviso Dada a possibilidade de emissão de radiação invisível através do orifício da via de acesso, quando esta não tiver nenhum cabo de fibra conectado, deverá evitar a exposição à radiação e não deverá olhar fixamente para orifícios que se encontrarem a descoberto.
¡Atención! Debido a que la apertura del puerto puede emitir radiación invisible cuando no existe un cable de fibra conectado, evite mirar directamente a las aperturas para no exponerse a la radiación.
Varning! Osynlig strålning kan avges från en portöppning utan ansluten fiberkabel och du bör därför undvika att bli utsatt för strålning genom att inte stirra in i oskyddade öppningar.
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 315
•
General Safety Warnings for Juniper Networks Devices on page 316
•
Installation Safety Warnings for Juniper Networks Devices on page 324
334 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 40
Maintenance and Operational Safety
Guidelines and Warnings
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 335
Maintenance and Operational Safety Warnings for Juniper Networks Devices
As you maintain the hardware equipment, observe the following warnings:
•
Battery Handling Warning on page 335
•
Jewelry Removal Warning on page 336
•
Lightning Activity Warning on page 337
•
Operating Temperature Warning on page 338
•
Product Disposal Warning on page 339
Battery Handling Warning
WARNING: Replacing the battery incorrectly might result in an explosion.
Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Waarschuwing Er is ontploffingsgevaar als de batterij verkeerd vervangen wordt. Vervang de batterij slechts met hetzelfde of een equivalent type dat door de fabrikant aanbevolen is. Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften weggeworpen te worden.
Varoitus Räjähdyksen vaara, jos akku on vaihdettu väärään akkuun. Käytä vaihtamiseen ainoastaan saman- tai vastaavantyyppistä akkua, joka on valmistajan suosittelema. Hävitä käytetyt akut valmistajan ohjeiden mukaan.
Attention Danger d'explosion si la pile n'est pas remplacée correctement.
Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant. Jeter les piles usagées conformément aux instructions du fabricant.
Copyright © 2015, Juniper Networks, Inc.
335
M320 Multiservice Edge Router Hardware Guide
Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr.
Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den
Anweisungen des Herstellers.
Avvertenza Pericolo di esplosione se la batteria non è installata correttamente. Sostituire solo con una di tipo uguale o equivalente, consigliata dal produttore. Eliminare le batterie usate secondo le istruzioni del produttore.
Advarsel Det kan være fare for eksplosjon hvis batteriet skiftes på feil måte.
Skift kun med samme eller tilsvarende type som er anbefalt av produsenten.
Kasser brukte batterier i henhold til produsentens instruksjoner.
Aviso Existe perigo de explosão se a bateria for substituída incorrectamente.
Substitua a bateria por uma bateria igual ou de um tipo equivalente recomendado pelo fabricante. Destrua as baterias usadas conforme as instruções do fabricante.
¡Atención! Existe peligro de explosión si la batería se reemplaza de manera incorrecta. Reemplazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante. Desechar las baterías gastadas según las instrucciones del fabricante.
Varning! Explosionsfara vid felaktigt batteribyte. Ersätt endast batteriet med samma batterityp som rekommenderas av tillverkaren eller motsvarande.
Följ tillverkarens anvisningar vid kassering av använda batterier.
Jewelry Removal Warning
WARNING: Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and watches. Metal objects heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals.
Waarschuwing Alvorens aan apparatuur te werken die met elektrische leidingen is verbonden, sieraden (inclusief ringen, kettingen en horloges) verwijderen. Metalen voorwerpen worden warm wanneer ze met stroom en aarde zijn verbonden, en kunnen ernstige brandwonden veroorzaken of het metalen voorwerp aan de aansluitklemmen lassen.
Varoitus Ennen kuin työskentelet voimavirtajohtoihin kytkettyjen laitteiden parissa, ota pois kaikki korut (sormukset, kaulakorut ja kellot mukaan lukien).
Metalliesineet kuumenevat, kun ne ovat yhteydessä sähkövirran ja maan kanssa, ja ne voivat aiheuttaa vakavia palovammoja tai hitsata metalliesineet kiinni liitäntänapoihin.
Attention Avant d'accéder à cet équipement connecté aux lignes électriques,
ôter tout bijou (anneaux, colliers et montres compris). Lorsqu'ils sont branchés
336 Copyright © 2015, Juniper Networks, Inc.
Chapter 40: Maintenance and Operational Safety Guidelines and Warnings
à l'alimentation et reliés à la terre, les objets métalliques chauffent, ce qui peut provoquer des blessures graves ou souder l'objet métallique aux bornes.
Warnung Vor der Arbeit an Geräten, die an das Netz angeschlossen sind, jeglichen Schmuck (einschließlich Ringe, Ketten und Uhren) abnehmen.
Metallgegenstände erhitzen sich, wenn sie an das Netz und die Erde angeschlossen werden, und können schwere Verbrennungen verursachen oder an die Anschlußklemmen angeschweißt werden.
Avvertenza Prima di intervenire su apparecchiature collegate alle linee di alimentazione, togliersi qualsiasi monile (inclusi anelli, collane, braccialetti ed orologi). Gli oggetti metallici si riscaldano quando sono collegati tra punti di alimentazione e massa: possono causare ustioni gravi oppure il metallo può saldarsi ai terminali.
Advarsel Fjern alle smykker (inkludert ringer, halskjeder og klokker) før du skal arbeide på utstyr som er koblet til kraftledninger. Metallgjenstander som er koblet til kraftledninger og jord blir svært varme og kan forårsake alvorlige brannskader eller smelte fast til polene.
Aviso Antes de trabalhar em equipamento que esteja ligado a linhas de corrente, retire todas as jóias que estiver a usar (incluindo anéis, fios e relógios). Os objectos metálicos aquecerão em contacto com a corrente e em contacto com a ligação à terra, podendo causar queimaduras graves ou ficarem soldados aos terminais.
¡Atención! Antes de operar sobre equipos conectados a líneas de alimentación, quitarse las joyas (incluidos anillos, collares y relojes). Los objetos de metal se calientan cuando se conectan a la alimentación y a tierra, lo que puede ocasionar quemaduras graves o que los objetos metálicos queden soldados a los bornes.
Varning! Tag av alla smycken (inklusive ringar, halsband och armbandsur) innan du arbetar på utrustning som är kopplad till kraftledningar. Metallobjekt hettas upp när de kopplas ihop med ström och jord och kan förorsaka allvarliga brännskador; metallobjekt kan också sammansvetsas med kontakterna.
Lightning Activity Warning
WARNING: Do not work on the system or connect or disconnect cables during periods of lightning activity.
Waarschuwing Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het systeem te werken of kabels aan te sluiten of te ontkoppelen.
Varoitus Älä työskentele järjestelmän parissa äläkä yhdistä tai irrota kaapeleita ukkosilmalla.
Copyright © 2015, Juniper Networks, Inc.
337
M320 Multiservice Edge Router Hardware Guide
Attention Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage.
Warnung Arbeiten Sie nicht am System und schließen Sie keine Kabel an bzw. trennen Sie keine ab, wenn es gewittert.
Avvertenza Non lavorare sul sistema o collegare oppure scollegare i cavi durante un temporale con fulmini.
Advarsel Utfør aldri arbeid på systemet, eller koble kabler til eller fra systemet når det tordner eller lyner.
Aviso Não trabalhe no sistema ou ligue e desligue cabos durante períodos de mau tempo (trovoada).
¡Atención! No operar el sistema ni conectar o desconectar cables durante el transcurso de descargas eléctricas en la atmósfera.
Varning! Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar.
Operating Temperature Warning
WARNING: To prevent the hardware equipment from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of 104° F (40° C). To prevent airflow restriction, allow at least
6 inches (15.2 cm) of clearance around the ventilation openings.
Waarschuwing Om te voorkomen dat welke router van de router dan ook oververhit raakt, dient u deze niet te bedienen op een plaats waar de maximale aanbevolen omgevingstemperatuur van 40° C wordt overschreden. Om te voorkomen dat de luchtstroom wordt beperkt, dient er minstens 15,2 cm speling rond de ventilatie-openingen te zijn.
Varoitus Ettei router-sarjan reititin ylikuumentuisi, sitä ei saa käyttää tilassa, jonka lämpötila ylittää korkeimman suositellun ympäristölämpötilan 40° C.
Ettei ilmanvaihto estyisi, tuuletusaukkojen ympärille on jätettävä ainakin
15,2 cm tilaa.
Attention Pour éviter toute surchauffe des routeurs de la gamme router, ne l'utilisez pas dans une zone où la température ambiante est supérieure à
40° C. Pour permettre un flot d'air constant, dégagez un espace d'au moins
15,2 cm autour des ouvertures de ventilations.
Warnung Um einen router der router vor Überhitzung zu schützen, darf dieser nicht in einer Gegend betrieben werden, in der die Umgebungstemperatur das empfohlene Maximum von 40° C überschreitet. Um Lüftungsverschluß zu verhindern, achten Sie darauf, daß mindestens 15,2 cm lichter Raum um die Lüftungsöffnungen herum frei bleibt.
338 Copyright © 2015, Juniper Networks, Inc.
Chapter 40: Maintenance and Operational Safety Guidelines and Warnings
Avvertenza Per evitare il surriscaldamento dei router, non adoperateli in un locale che ecceda la temperatura ambientale massima di 40° C. Per evitare che la circolazione dell'aria sia impedita, lasciate uno spazio di almeno 15.2 cm di fronte alle aperture delle ventole.
Advarsel Unngå overoppheting av eventuelle rutere i router Disse skal ikke brukes på steder der den anbefalte maksimale omgivelsestemperaturen overstiger 40° C (104° F). Sørg for at klaringen rundt lufteåpningene er minst
15,2 cm (6 tommer) for å forhindre nedsatt luftsirkulasjon.
Aviso Para evitar o sobreaquecimento do encaminhador router, não utilize este equipamento numa área que exceda a temperatura máxima recomendada de 40° C. Para evitar a restrição à circulação de ar, deixe pelo menos um espaço de 15,2 cm à volta das aberturas de ventilação.
¡Atención! Para impedir que un encaminador de la serie router se recaliente, no lo haga funcionar en un área en la que se supere la temperatura ambiente máxima recomendada de 40° C. Para impedir la restricción de la entrada de aire, deje un espacio mínimo de 15,2 cm alrededor de las aperturas para ventilación.
Varning! Förhindra att en router överhettas genom att inte använda den i ett område där den maximalt rekommenderade omgivningstemperaturen på
40° C överskrids. Förhindra att luftcirkulationen inskränks genom att se till att det finns fritt utrymme på minst 15,2 cm omkring ventilationsöppningarna.
Product Disposal Warning
WARNING: Disposal of this product must be handled according to all national laws and regulations.
Waarschuwing Dit produkt dient volgens alle landelijke wetten en voorschriften te worden afgedankt.
Varoitus Tämän tuotteen lopullisesta hävittämisestä tulee huolehtia kaikkia valtakunnallisia lakeja ja säännöksiä noudattaen.
Attention La mise au rebut définitive de ce produit doit être effectuée conformément à toutes les lois et réglementations en vigueur.
Warnung Dieses Produkt muß den geltenden Gesetzen und Vorschriften entsprechend entsorgt werden.
Avvertenza L'eliminazione finale di questo prodotto deve essere eseguita osservando le normative italiane vigenti in materia
Advarsel Endelig disponering av dette produktet må skje i henhold til nasjonale lover og forskrifter.
Copyright © 2015, Juniper Networks, Inc.
339
M320 Multiservice Edge Router Hardware Guide
Aviso A descartagem final deste produto deverá ser efectuada de acordo com os regulamentos e a legislação nacional.
¡Atención! El desecho final de este producto debe realizarse según todas las leyes y regulaciones nacionales
Varning! Slutlig kassering av denna produkt bör skötas i enlighet med landets alla lagar och föreskrifter.
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 315
•
General Safety Warnings for Juniper Networks Devices on page 316
340 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 41
Electrical Safety Guidelines and Warnings
•
General Electrical Safety Warnings for Juniper Networks Devices on page 341
•
General Electrical Safety Guidelines and Electrical Codes for Juniper Networks
•
M320 AC Power Electrical Safety Guidelines on page 345
•
M320 AC Power Electrical Safety Warning on page 346
•
M320 DC Power Electrical Safety Guidelines on page 346
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 347
General Electrical Safety Warnings for Juniper Networks Devices
•
Grounded Equipment Warning on page 341
•
Grounding Requirements and Warning on page 342
•
Midplane Energy Hazard Warning on page 343
•
Multiple Power Supplies Disconnection Warning on page 343
•
Power Disconnection Warning on page 344
Grounded Equipment Warning
WARNING: The network device is intended to be grounded. Ensure that the network device is connected to earth ground during normal use.
Waarschuwing Deze apparatuur hoort geaard te worden Zorg dat de host-computer tijdens normaal gebruik met aarde is verbonden.
Varoitus Tämä laitteisto on tarkoitettu maadoitettavaksi. Varmista, että isäntälaite on yhdistetty maahan normaalikäytön aikana.
Attention Cet équipement doit être relié à la terre. S'assurer que l'appareil hôte est relié à la terre lors de l'utilisation normale.
Warnung Dieses Gerät muß geerdet werden. Stellen Sie sicher, daß das
Host-Gerät während des normalen Betriebs an Erde gelegt ist.
Copyright © 2015, Juniper Networks, Inc.
341
M320 Multiservice Edge Router Hardware Guide
Avvertenza Questa apparecchiatura deve essere collegata a massa. Accertarsi che il dispositivo host sia collegato alla massa di terra durante il normale utilizzo.
Advarsel Dette utstyret skal jordes. Forviss deg om vertsterminalen er jordet ved normalt bruk.
Aviso Este equipamento deverá estar ligado à terra. Certifique-se que o host se encontra ligado à terra durante a sua utilização normal.
¡Atención! Este equipo debe conectarse a tierra. Asegurarse de que el equipo principal esté conectado a tierra durante el uso normal.
Varning! Denna utrustning är avsedd att jordas. Se till att värdenheten är jordad vid normal användning.
Grounding Requirements and Warning
An insulated grounding conductor that is identical in size to the grounded and ungrounded branch circuit supply conductors, but is identifiable by green and yellow stripes, is installed as part of the branch circuit that supplies the unit. The grounding conductor is a separately derived system at the supply transformer or motor generator set.
WARNING: When installing the network device, you must always make the ground connection first and disconnect it last.
Waarschuwing Bij de installatie van het toestel moet de aardverbinding altijd het eerste worden gemaakt en het laatste worden losgemaakt.
Varoitus Laitetta asennettaessa on maahan yhdistäminen aina tehtävä ensiksi ja maadoituksen irti kytkeminen viimeiseksi.
Attention Lors de l'installation de l'appareil, la mise à la terre doit toujours
être connectée en premier et déconnectée en dernier.
Warnung Der Erdanschluß muß bei der Installation der Einheit immer zuerst hergestellt und zuletzt abgetrennt werden.
Avvertenza In fase di installazione dell'unità, eseguire sempre per primo il collegamento a massa e disconnetterlo per ultimo.
Advarsel Når enheten installeres, må jordledningen alltid tilkobles først og frakobles sist.
Aviso Ao instalar a unidade, a ligação à terra deverá ser sempre a primeira a ser ligada, e a última a ser desligada.
¡Atención! Al instalar el equipo, conectar la tierra la primera y desconectarla la última.
342 Copyright © 2015, Juniper Networks, Inc.
Chapter 41: Electrical Safety Guidelines and Warnings
Varning! Vid installation av enheten måste jordledningen alltid anslutas först och kopplas bort sist.
Midplane Energy Hazard Warning
WARNING: High levels of electrical energy are distributed across the midplane.
Be careful not to contact the midplane connectors, or any component connected to the midplane, with any metallic object while servicing components.
Multiple Power Supplies Disconnection Warning
WARNING: The network device has more than one power supply connection.
All connections must be removed completely to remove power from the unit completely.
Waarschuwing Deze eenheid heeft meer dan één stroomtoevoerverbinding; alle verbindingen moeten volledig worden verwijderd om de stroom van deze eenheid volledig te verwijderen.
Varoitus Tässä laitteessa on useampia virtalähdekytkentöjä. Kaikki kytkennät on irrotettava kokonaan, jotta virta poistettaisiin täysin laitteesta.
Attention Cette unité est équipée de plusieurs raccordements d'alimentation.
Pour supprimer tout courant électrique de l'unité, tous les cordons d'alimentation doivent être débranchés.
Warnung Diese Einheit verfügt über mehr als einen Stromanschluß; um Strom gänzlich von der Einheit fernzuhalten, müssen alle Stromzufuhren abgetrennt sein.
Avvertenza Questa unità ha più di una connessione per alimentatore elettrico; tutte le connessioni devono essere completamente rimosse per togliere l'elettricità dall'unità.
Advarsel Denne enheten har mer enn én strømtilkobling. Alle tilkoblinger må kobles helt fra for å eliminere strøm fra enheten.
Aviso Este dispositivo possui mais do que uma conexão de fonte de alimentação de energia; para poder remover a fonte de alimentação de energia, deverão ser desconectadas todas as conexões existentes.
¡Atención! Esta unidad tiene más de una conexión de suministros de alimentación; para eliminar la alimentación por completo, deben desconectarse completamente todas las conexiones.
Copyright © 2015, Juniper Networks, Inc.
343
M320 Multiservice Edge Router Hardware Guide
Varning! Denna enhet har mer än en strömförsörjningsanslutning; alla anslutningar måste vara helt avlägsnade innan strömtillförseln till enheten
är fullständigt bruten.
Power Disconnection Warning
WARNING: Before working on the chassis or near power supplies, switch off the power at the DC circuit breaker.
Waarschuwing Voordat u aan een frame of in de nabijheid van voedingen werkt, dient u bij wisselstroom toestellen de stekker van het netsnoer uit het stopcontact te halen; voor gelijkstroom toestellen dient u de stroom uit te schakelen bij de stroomverbreker.
Varoitus Kytke irti vaihtovirtalaitteiden virtajohto ja katkaise tasavirtalaitteiden virta suojakytkimellä, ennen kuin teet mitään asennuspohjalle tai työskentelet virtalähteiden läheisyydessä.
Attention Avant de travailler sur un châssis ou à proximité d'une alimentation
électrique, débrancher le cordon d'alimentation des unités en courant alternatif; couper l'alimentation des unités en courant continu au niveau du disjoncteur.
Warnung Bevor Sie an einem Chassis oder in der Nähe von Netzgeräten arbeiten, ziehen Sie bei Wechselstromeinheiten das Netzkabel ab bzw.
schalten Sie bei Gleichstromeinheiten den Strom am Unterbrecher ab.
Avvertenza Prima di lavorare su un telaio o intorno ad alimentatori, scollegare il cavo di alimentazione sulle unità CA; scollegare l'alimentazione all'interruttore automatico sulle unità CC.
Advarsel Før det utføres arbeid på kabinettet eller det arbeides i nærheten av strømforsyningsenheter, skal strømledningen trekkes ut p vekselstrømsenheter og strømmen kobles fra ved strømbryteren på likestrømsenheter.
Aviso Antes de trabalhar num chassis, ou antes de trabalhar perto de unidades de fornecimento de energia, desligue o cabo de alimentação nas unidades de corrente alternada; desligue a corrente no disjuntor nas unidades de corrente contínua.
¡Atención! Antes de manipular el chasis de un equipo o trabajar cerca de una fuente de alimentación, desenchufar el cable de alimentación en los equipos de corriente alterna (CA); cortar la alimentación desde el interruptor automático en los equipos de corriente continua (CC).
Varning! Innan du arbetar med ett chassi eller nära strömförsörjningsenheter skall du för växelströmsenheter dra ur nätsladden och för likströmsenheter bryta strömmen vid överspänningsskyddet.
344 Copyright © 2015, Juniper Networks, Inc.
Chapter 41: Electrical Safety Guidelines and Warnings
Related
Documentation
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 347
General Electrical Safety Guidelines and Electrical Codes for Juniper Networks Devices
• Install the router in compliance with the following local, national, or international electrical codes:
•
United States—National Fire Protection Association (NFPA 70), United States
National Electrical Code.
• Canada—Canadian Electrical Code, Part 1, CSA C22.1.
• Other countries—International Electromechanical Commission (IEC) 60364, Part 1 through Part 7.
•
Locate the emergency power-off switch for the room in which you are working so that if an electrical accident occurs, you can quickly turn off the power.
• Do not work alone if potentially hazardous conditions exist anywhere in your workspace.
• Never assume that power is disconnected from a circuit. Always check the circuit before starting to work.
•
Carefully look for possible hazards in your work area, such as moist floors, ungrounded power extension cords, and missing safety grounds.
• Operate the router within marked electrical ratings and product usage instructions.
•
For the router and peripheral equipment to function safely and correctly, use the cables and connectors specified for the attached peripheral equipment, and make certain they are in good condition.
Many router components can be removed and replaced without powering off or disconnecting power to the router. Never install equipment if it appears damaged.
Related
Documentation
•
In Case of an Electrical Accident
M320 AC Power Electrical Safety Guidelines
The following electrical safety guidelines apply to an AC-powered M320 router:
• AC-powered routers are shipped with three-wire electrical cords with a grounding-type plug that fits only a grounding-type power outlet. Do not circumvent this safety feature.
Equipment grounding should comply with local and national electrical codes.
•
You must provide an external listed circuit breaker rated minimum 15 A (250 VAC) for each AC power supply.
• The cores in the mains lead are colored in accordance with the following code:
•
Green and yellow—Earth
•
Blue—Neutral
Copyright © 2015, Juniper Networks, Inc.
345
M320 Multiservice Edge Router Hardware Guide
•
Brown—Live
Related
Documentation
•
M320 AC Power Supplies Description on page 73
•
Connecting Power to an AC-Powered M320 Router on page 173
•
M320 AC Power Electrical Specifications on page 101
M320 AC Power Electrical Safety Warning
The power cable warning in Japanese is as follows:
WARNING: The attached power cable is only for this product. Do not use the cable for another product.
M320 DC Power Electrical Safety Guidelines
The following electrical safety guidelines apply to an M320 DC-powered router:
•
A DC-powered router is equipped with a DC terminal block that is rated for the power requirements of a maximally configured router. To supply sufficient power, terminate the DC input wiring on a facility DC source capable of supplying at least 65 A @ –48 VDC for the system, or at least 48 A @ –48 VDC for each power supply. We recommend that the 48 VDC facility DC source be equipped with a circuit breaker rated at
60 A (–48 VDC) minimum, or as required by local code. Incorporate an easily accessible disconnect device into the facility wiring. In the United States and Canada, the –48
VDC facility should be equipped with a circuit breaker rated a minimum of 125% of the power provisioned for the input in accordance with the National Electrical Code in the
US and the Canadian Electrical Code in Canada. Be sure to connect the ground wire or conduit to a solid office (earth) ground. A closed loop ring is recommended for terminating the ground conductor at the ground stud.
•
Run two wires from the circuit breaker box to a source of 48 VDC. Use appropriate gauge wire to handle up to 60 A.
• A DC-powered router that is equipped with a DC terminal block is intended only for installation in a restricted access location. In the United States, a restricted access area is one in accordance with Articles 110-16, 110-17, and 110-18 of the National Electrical
Code ANSI/NFPA 70.
346 Copyright © 2015, Juniper Networks, Inc.
Chapter 41: Electrical Safety Guidelines and Warnings
NOTE: Primary overcurrent protection is provided by the building circuit breaker. This breaker should protect against excess currents, short circuits, and earth faults in accordance with NEC ANSI/NFPA70.
•
Ensure that the polarity of the DC input wiring is correct. Under certain conditions, connections with reversed polarity might trip the primary circuit breaker or damage the equipment.
•
For personal safety, connect the green and yellow wire to safety (earth) ground at both the router and the supply side of the DC wiring.
• The marked input voltage of –48 VDC for a DC-powered router is the nominal voltage associated with the battery circuit, and any higher voltages are only to be associated with float voltages for the charging function.
•
Because the router is a positive ground system, you must connect the positive lead to the terminal labeled RETURN, the negative lead to the terminal labeled –48V, and the earth ground to the chassis grounding points.
Related
Documentation
•
M320 DC Power Supplies Description on page 74
•
Connecting Power to a DC-Powered M320 Router on page 174
•
M320 DC Power Electrical Specifications on page 105
DC Power Electrical Safety Warnings for Juniper Networks Devices
When working with DC-powered equipment, observe the following warnings:
•
DC Power Copper Conductors Warning on page 347
•
DC Power Disconnection Warning on page 348
•
DC Power Wiring Terminations Warning on page 349
DC Power Copper Conductors Warning
WARNING: Use copper conductors only.
Waarschuwing Gebruik alleen koperen geleiders.
Varoitus Käytä vain kuparijohtimia.
Attention Utilisez uniquement des conducteurs en cuivre.
Warnung Verwenden Sie ausschließlich Kupferleiter.
Avvertenza Usate unicamente dei conduttori di rame.
Advarsel Bruk bare kobberledninger.
Aviso Utilize apenas fios condutores de cobre.
Copyright © 2015, Juniper Networks, Inc.
347
M320 Multiservice Edge Router Hardware Guide
¡Atención! Emplee sólo conductores de cobre.
Varning! Använd endast ledare av koppar.
DC Power Disconnection Warning
WARNING: Before performing any procedures on power supplies, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position.
Waarschuwing Voordat u een van de onderstaande procedures uitvoert, dient u te controleren of de stroom naar het gelijkstroom circuit uitgeschakeld is. Om u ervan te verzekeren dat alle stroom UIT is geschakeld, kiest u op het schakelbord de stroomverbreker die het gelijkstroom circuit bedient, draait de stroomverbreker naar de UIT positie en plakt de schakelaarhendel van de stroomverbreker met plakband in de UIT positie vast.
Varoitus Varmista, että tasavirtapiirissä ei ole virtaa ennen seuraavien toimenpiteiden suorittamista. Varmistaaksesi, että virta on KATKAISTU täysin, paikanna tasavirrasta huolehtivassa kojetaulussa sijaitseva suojakytkin, käännä suojakytkin KATKAISTU-asentoon ja teippaa suojakytkimen varsi niin, että se pysyy KATKAISTU-asennossa.
Attention Avant de pratiquer l'une quelconque des procédures ci-dessous, vérifier que le circuit en courant continu n'est plus sous tension. Pour en être sûr, localiser le disjoncteur situé sur le panneau de service du circuit en courant continu, placer le disjoncteur en position fermée (OFF) et, à l'aide d'un ruban adhésif, bloquer la poignée du disjoncteur en position OFF.
Warnung Vor Ausführung der folgenden Vorgänge ist sicherzustellen, daß die Gleichstromschaltung keinen Strom erhält. Um sicherzustellen, daß sämtlicher Strom abgestellt ist, machen Sie auf der Schalttafel den
Unterbrecher für die Gleichstromschaltung ausfindig, stellen Sie den
Unterbrecher auf AUS, und kleben Sie den Schaltergriff des Unterbrechers mit Klebeband in der AUS-Stellung fest.
Avvertenza Prima di svolgere una qualsiasi delle procedure seguenti, verificare che il circuito CC non sia alimentato. Per verificare che tutta l'alimentazione sia scollegata (OFF), individuare l'interruttore automatico sul quadro strumenti che alimenta il circuito CC, mettere l'interruttore in posizione OFF e fissarlo con nastro adesivo in tale posizione.
Advarsel Før noen av disse prosedyrene utføres, kontroller at strømmen er frakoblet likestrømkretsen. Sørg for at all strøm er slått AV. Dette gjøres ved
å lokalisere strømbryteren på brytertavlen som betjener likestrømkretsen, slå strømbryteren AV og teipe bryterhåndtaket på strømbryteren i AV-stilling.
348 Copyright © 2015, Juniper Networks, Inc.
Chapter 41: Electrical Safety Guidelines and Warnings
Aviso Antes de executar um dos seguintes procedimentos, certifique-se que desligou a fonte de alimentação de energia do circuito de corrente contínua.
Para se assegurar que toda a corrente foi DESLIGADA, localize o disjuntor no painel que serve o circuito de corrente contínua e coloque-o na posição OFF
(Desligado), segurando nessa posição a manivela do interruptor do disjuntor com fita isoladora.
¡Atención! Antes de proceder con los siguientes pasos, comprobar que la alimentación del circuito de corriente continua (CC) esté cortada (OFF). Para asegurarse de que toda la alimentación esté cortada (OFF), localizar el interruptor automático en el panel que alimenta al circuito de corriente continua, cambiar el interruptor automático a la posición de Apagado (OFF), y sujetar con cinta la palanca del interruptor automático en posición de
Apagado (OFF).
Varning! Innan du utför någon av följande procedurer måste du kontrollera att strömförsörjningen till likströmskretsen är bruten. Kontrollera att all strömförsörjning är BRUTEN genom att slå AV det överspänningsskydd som skyddar likströmskretsen och tejpa fast överspänningsskyddets omkopplare i FRÅN-läget.
DC Power Wiring Terminations Warning
WARNING: When stranded wiring is required, use approved wiring terminations, such as closed-loop or spade-type with upturned lugs. These terminations should be the appropriate size for the wires and should clamp both the insulation and conductor.
Waarschuwing Wanneer geslagen bedrading vereist is, dient u bedrading te gebruiken die voorzien is van goedgekeurde aansluitingspunten, zoals het gesloten-lus type of het grijperschop type waarbij de aansluitpunten omhoog wijzen. Deze aansluitpunten dienen de juiste maat voor de draden te hebben en dienen zowel de isolatie als de geleider vast te klemmen.
Varoitus Jos säikeellinen johdin on tarpeen, käytä hyväksyttyä johdinliitäntää, esimerkiksi suljettua silmukkaa tai kourumaista liitäntää, jossa on ylöspäin käännetyt kiinnityskorvat. Tällaisten liitäntöjen tulee olla kooltaan johtimiin sopivia ja niiden tulee puristaa yhteen sekä eristeen että johdinosan.
Attention Quand des fils torsadés sont nécessaires, utiliser des douilles terminales homologuées telles que celles à circuit fermé ou du type à plage ouverte avec cosses rebroussées. Ces douilles terminales doivent être de la taille qui convient aux fils et doivent être refermées sur la gaine isolante et sur le conducteur.
Warnung Wenn Litzenverdrahtung erforderlich ist, sind zugelassene
Verdrahtungsabschlüsse, z.B. Ringoesen oder gabelförmige Kabelschuhe mit nach oben gerichteten Enden zu verwenden. Diese Abschlüsse sollten
Copyright © 2015, Juniper Networks, Inc.
349
M320 Multiservice Edge Router Hardware Guide die angemessene Größe für die Drähte haben und sowohl die Isolierung als auch den Leiter festklemmen.
Avvertenza Quando occorre usare trecce, usare connettori omologati, come quelli a occhiello o a forcella con linguette rivolte verso l'alto. I connettori devono avere la misura adatta per il cablaggio e devono serrare sia l'isolante che il conduttore.
Advarsel Hvis det er nødvendig med flertrådede ledninger, brukes godkjente ledningsavslutninger, som for eksempel lukket sløyfe eller spadetype med oppoverbøyde kabelsko. Disse avslutningene skal ha riktig størrelse i forhold til ledningene, og skal klemme sammen både isolasjonen og lederen.
Aviso Quando forem requeridas montagens de instalação eléctrica de cabo torcido, use terminações de cabo aprovadas, tais como, terminações de cabo em circuito fechado e planas com terminais de orelha voltados para cima.
Estas terminações de cabo deverão ser do tamanho apropriado para os respectivos cabos, e deverão prender simultaneamente o isolamento e o fio condutor.
¡Atención! Cuando se necesite hilo trenzado, utilizar terminales para cables homologados, tales como las de tipo "bucle cerrado" o "espada", con las lengüetas de conexión vueltas hacia arriba. Estos terminales deberán ser del tamaño apropiado para los cables que se utilicen, y tendrán que sujetar tanto el aislante como el conductor.
Varning! När flertrådiga ledningar krävs måste godkända ledningskontakter användas, t.ex. kabelsko av sluten eller öppen typ med uppåtvänd tapp.
Storleken på dessa kontakter måste vara avpassad till ledningarna och måste kunna hålla både isoleringen och ledaren fastklämda.
Related
Documentation
•
General Safety Warnings for Juniper Networks Devices on page 316
•
General Electrical Safety Warnings for Juniper Networks Devices on page 341
350 Copyright © 2015, Juniper Networks, Inc.
CHAPTER 42
Agency Approvals and Compliance
Statements
•
M320 Agency Approvals on page 351
•
Compliance Statements for EMC Requirements for Juniper Networks Devices
•
M320 Compliance Statements for EMC Requirements (European
•
Compliance Statements for EMC Requirements for Juniper Networks Devices
•
Compliance Statements for EMC Requirements for Juniper Networks Devices
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (United
•
Compliance Statements for Environmental Requirements for Juniper Networks
•
M320 Compliance Statements for NEBs on page 354
•
M320 Compliance Statements for Acoustic Noise on page 354
M320 Agency Approvals
The router complies with the following standards:
• Safety
•
CAN/CSA-22.2 No. 60950–1–07/UL 60950–1, 2nd Ed., Safety of Information
Technology Equipment
• EN 60825-1 Safety of Laser Products - Part 1: Equipment Classification, Requirements and User's Guide
• EMC
•
AS/NZS 3548 Class A (Australia/New Zealand)
•
EN55022 Class A (Europe)
Copyright © 2015, Juniper Networks, Inc.
351
M320 Multiservice Edge Router Hardware Guide
•
FCC Part 15 Class A (USA)
• VCCI Class A (Japan)
• Immunity
• EN-61000-3-3 Voltage Fluctuations and Flicker
•
EN-61000-4-2 ESD
•
EN-61000-4-3 Radiated Immunity
• EN-61000-4-4 EFT
• EN-61000-4-5 Surge
•
EN-61000-4-6 Low Frequency Common Immunity
•
ETSI EN-300386-2 Telecommunication Network Equipment. Electromagnetic
Compatibility Requirements
• NEBS
• GR-1089-Core: EMC and Electrical Safety for Network Telecommunications
Equipment
•
SR-3580 NEBS Criteria Levels (Level 3 Compliance)
• GR-63-Core: NEBS, Physical Protection
Related
Documentation
•
M320 Router Description on page 3
•
M320 Environmental Specifications on page 93
•
M320 Chassis Description on page 7
Compliance Statements for EMC Requirements for Juniper Networks Devices (Canada)
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Related
Documentation
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (Israel) on page 353
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (Japan) on page 353
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (United
M320 Compliance Statements for EMC Requirements (European Community)
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
352 Copyright © 2015, Juniper Networks, Inc.
Chapter 42: Agency Approvals and Compliance Statements
Related
Documentation
•
M320 Agency Approvals on page 351
Compliance Statements for EMC Requirements for Juniper Networks Devices (Israel)
Translation from Hebrew—Warning: This product is Class A. In residential environments, the product may cause radio interference, and in such a situation, the user may be required to take adequate measures.
Related
Documentation
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (Canada) on page 352
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (Japan) on page 353
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (United
Compliance Statements for EMC Requirements for Juniper Networks Devices (Japan)
Translation from Japanese—This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. VCCI-A
Related
Documentation
Compliance Statements for EMC Requirements for Juniper Networks Devices (United
States)
The hardware equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment
Copyright © 2015, Juniper Networks, Inc.
353
M320 Multiservice Edge Router Hardware Guide in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Related
Documentation
Compliance Statements for Environmental Requirements for Juniper Networks Devices
Batteries in this product are not based on mercury, lead, or cadmium substances. The batteries used in this product are in compliance with EU Directives 91/157/EEC, 93/86/EEC, and 98/101/EEC. The product documentation includes instructional information about the proper method of reclamation and recycling.
Related
Documentation
M320 Compliance Statements for NEBs
• The equipment is suitable for installation as part of the Common Bonding Network
(CBN).
•
The equipment is suitable for installation in locations where the National Electrical
Code (NEC) applies.
• The battery return connection is to be treated as an isolated DC return (i.e. DC-I), as defined in GR-1089-CORE.
•
For Juniper systems with AC power supplies, an external surge protective device (SPD) must be used at the AC power source.
Related
Documentation
•
M320 Agency Approvals on page 351
M320 Compliance Statements for Acoustic Noise
• Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 74 dB(A) oder weniger gemäss EN ISO 7779
•
Translation—The emitted sound pressure resulted in 74 dB(A) per EN ISO 7779.
Related
Documentation
•
M320 Router Description on page 3
•
M320 Chassis Description on page 7
•
M320 Environmental Specifications on page 93
354 Copyright © 2015, Juniper Networks, Inc.
PART 9
Index
•
Copyright © 2015, Juniper Networks, Inc.
355
M320 Multiservice Edge Router Hardware Guide
356 Copyright © 2015, Juniper Networks, Inc.
Index
Symbols
#, comments in configuration statements..................
( ), in syntax descriptions...................................................
< >, in syntax descriptions.................................................
[ ], in configuration statements.......................................
{ }, in configuration statements.......................................
| (pipe), in syntax descriptions.........................................
A
AC plug types..........................................................................
AC power cables specifications.................................................................
AC power cord specifications.................................................................
AC power supply cord See AC power cord
electrical specifications...............................................
AC power supply cord
replacing.........................................................................
accessory box parts list............................................................................
removing..........................................................................
agency approvals..................................................................
air filters maintaining....................................................................
replacing.........................................................................
airflow required clearance around chassis for....................
alarm messages, list of..........................................................
relay contacts
connecting/disconnecting wire......................
alarms mode for LED display.....................................................
relay contacts...................................................................
wire specifications................................................
temperature, displaying............................................
altitude, acceptable range..................................................
antistatic mat, using............................................................
approvals, agency.................................................................
ATM analyzer, use of............................................................
attenuation in fiber-optic cable.........................................
auxiliary port..............................................................................
auxiliary port (for Routing Engine management) cable
connection during initial installation............
connector pinouts (DB-9)................................
replacement instructions.................................
specifications.........................................................
B
battery environmental compliance.....................................
handling warning.........................................................
lithium..............................................................................
booting the router..................................................................
braces, in configuration statements...............................
brackets
angle, in syntax descriptions....................................
xxv square, in configuration statements.....................
C
cable auxiliary or console port (for Routing Engine management) replacing.................................................................
cover installation.............................................................
Ethernet port (for Routing Engine management)
replacing.................................................................
fiber-optic
cleaning instructions for transceivers.........
guards installation....................................................
,
PIC connecting during maintenance...................
disconnecting.......................................................
maintaining...........................................................
power See AC power cord cable cover installation......................................................................
cable guards
installation.............................................................
cable management system
description.........................................................................
fiber-optic cable, use with........................................
installation......................................................................
removal............................................................................
Copyright © 2015, Juniper Networks, Inc.
357
M320 Multiservice Edge Router Hardware Guide cables auxiliary or console port (for Routing Engine management) connecting during initial installation............
Ethernet port (for Routing Engine management) connecting during initial installation...........
fiber-optic attenuation...............................................................
111 dispersion.................................................................
multimode and single-mode............................
transmission distance, maximum...................
wavelength ranges................................................
case number, for JTAC.........................................................
CBs components.....................................................................
description........................................................................
LEDs....................................................................................
maintaining....................................................................
replacing..........................................................................
taking offline...................................................................
chassis............................................................................................
alarm messages See alarm, messages
dimensions.......................................................................
ESD points...........................................................................
grounding points........................................................
,
installing in rack............................................................
weight................................................................................
checklist for site preparation..............................................
chromatic dispersion in fiber-optic cable......................
CIP
alarm relay contacts......................................................
description.........................................................................
replacing..........................................................................
Routing Engine ports.....................................................
Class 1 laser warning............................................................
Class 1 LED warning.............................................................
cleaning instructions
fiber-optic transceivers.............................................
clearance, around rack...........................................................
CLI as troubleshooting tool.............................................
command to display chassis alarm messages.............
to display FPC status.........................................
to display PIC status..........................................
to display serial number..................................
clocking device
connecting......................................................................
commands ping...................................................................................
show chassis alarms..................................................
show chassis fpc for FPC status.......................................................
show chassis fpc pic-status....................................
show chassis hardware............................................
traceroute.......................................................................
comments, in configuration statements......................
compatibility, electromagnetic.........................................
compliance
EMC (electromagnetic compatibility) requirements (Canada)........................................
EMC requirements.......................................................
EMC requirements (Israel).......................................
EMC requirements (Japan)......................................
EMC requirements (United States)......................
general standards........................................................
components cable management system........................................
CB.........................................................................................
chassis...................................................................................
CIP.........................................................................................
cooling system.................................................................
craft interface...................................................................
field replacement.........................................................
FPCs....................................................................................
host subsystem...............................................................
midplane............................................................................
packing for shipment..................................................
PICs.....................................................................................
redundancy.........................................................................
Routing Engine.........................................................
,
SIBs......................................................................................
configuration
router.................................................................................
Connector Interface Panel See CIP console port (for Routing Engine management) cable
connection during initial installation............
connector pinout (DB-9)...................................
connector pinout (RJ-45).................................
replacement instructions.................................
specifications.........................................................
Control Boards See CBs control boards
maintaining....................................................................
conventions
text and syntax.............................................................
358 Copyright © 2015, Juniper Networks, Inc.
Index cooling system description.........................................................................
troubleshooting............................................................
copper conductors warning (DC power).....................
craft interface
description.........................................................................
FPC online/offline buttons..........................................
host subsystem LEDs....................................................
LED display........................................................................
power supply LEDs.........................................................
replacing...........................................................................
curly braces, in configuration statements....................
customer support.................................................................
contacting.......................................................................
contacting JTAC...........................................................
D
DB-9 cable connector pinouts (auxiliary and console ports)......................................................................................
DC power
copper conductors warning.....................................
disconnection warning..............................................
grounding equipment warning................................
grounding requirements warning..........................
power supplies disconnection warning..............
removal warning..........................................................
wiring terminations warning...................................
DC power cables
lugs.....................................................................................
107 specifications.................................................................
DC power supplies
multiple disconnection warning............................
DC power supply cables See DC power cables
electrical specifications...............................................
DC power supply cord replacing.........................................................................
DC specifications electrical...........................................................................
dispersion in fiber-optic cable............................................
documentation comments on.................................................................
E
earthquakes site preparation for........................................................
tested toleration for seismic......................................
EIA rack standards..................................................................
electrical codes.....................................................................
electrical specifications..............................................
electricity safety warnings.............................................................
site wiring guidelines....................................................
electromagnetic compatibility See EMC (electromagnetic compatibility)
pulse...................................................................................
electrostatic bag using to store components.......................................
em0..............................................................................................
EMC (electromagnetic compatibility) compliance with requirements (Canada).........
compliance with requirements (Israel)..............
353 compliance with requirements (Japan).............
compliance with requirements (United
States).........................................................................
suppression......................................................................
EMC (EMI) compliance with requirements..............................
standards.........................................................................
EMP (electromagnetic pulse)...........................................
environmental specifications.............................................
ESD preventing damage to components by...............
Ethernet port (for Routing Engine management) cable connection during initial installation...........
replacement instructions.................................
specifications.........................................................
description.........................................................................
ETSI rack standards...............................................................
external clock input (CB) cable
connector pinout (RJ-48).................................
connecting......................................................................
F
fan trays
description.........................................................................
maintaining...................................................................
replacing.........................................................................
troubleshooting............................................................
fiber-optic power budget calculation...........................................
field-replaceable units
listed..................................................................................
fire safety requirements......................................................
Flexible PIC Concentrators See FPCs
Copyright © 2015, Juniper Networks, Inc.
359
M320 Multiservice Edge Router Hardware Guide
font conventions...................................................................
FPCs.............................................................................................
components....................................................................
maintenance.................................................................
online/offline buttons...................................................
replacing..........................................................................
status, checking.................................................
,
troubleshooting...........................................................
fuses description (hardware and function)......................
replacement of blown................................................
specifications..................................................................
use in troubleshooting..............................................
fxp0..............................................................................................
G
grounding
equipment warning.....................................................
requirements warning................................................
grounding (electrical) specifications
DC-powered Router......................................................
grounding cables
lug........................................................................................
guidelines
electrical cable and wiring.........................................
safety ................................................................................
H
hardware components power requirements.....................................................
higher-order mode loss (HOL)...........................................
host subsystem description........................................................................
LEDs.....................................................................................
maintaining....................................................................
taking offline...................................................................
hot-pluggable components, description.....................
humidity (relative), acceptable.........................................
I
immunity standards.............................................................
inserting
PC card.............................................................................
installation
AC power, connecting..................................................
DC power, connecting.................................................
parts received, verifying..............................................
PICs, connecting...........................................................
router.................................................................................
unpacking the router...................................................
installation handle
attaching.................................................................
,
removing..........................................................................
installation instructions alarm relay contact wires during initial installation...................................
for maintenance or replacement...................
tools required........................................................
cable, auxiliary or console port (for Routing
Engine management)
during initial installation...................................
for maintenance or replacement..................
tools required........................................................
cable, Ethernet port (for Routing Engine management) during initial installation...................................
for maintenance or replacement...................
tools required........................................................
cable, PIC for maintenance or replacement.................
DC power and grounding cables tools required........................................................
fuses..................................................................................
SFP....................................................................................
XENPAK module..........................................................
installation warning.............................................................
instructions calculation
power requirements............................................
cleaning See cleaning instructions maintenance
PIC.............................................................................
packing
router for shipment...........................................
interface network...............................................................................
interference electromagnetic.............................................................
95 radio frequency...............................................................
J
jewelry removal warning...................................................
L
laser beam warning...............................................................
Class 1 laser warning...................................................
360 Copyright © 2015, Juniper Networks, Inc.
Index
LED display on craft interface alarm mode.......................................................................
description.........................................................................
idle mode............................................................................
LEDs
AC and DC power supplies.........................................
CB........................................................................................
Class 1 LED warning....................................................
host subsystem...............................................................
power supplies.................................................................
Routing Engine.................................................................
safety warnings.............................................................
SIB..................................................................................
lightning activity warning...................................................
link loss, calculating...............................................................
lithium battery compliance..............................................
lug for grounding cables.......................................................
lugs for DC power cables....................................................
M
maintaining
air filters...........................................................................
fan trays..........................................................................
host subsystem............................................................
power supplies..............................................................
SIBs...................................................................................
maintenance guidelines cable
PIC.............................................................................
FPC....................................................................................
PIC.....................................................................................
warnings..........................................................................
management interface.........................................................
34 em0.....................................................................................
34 fxp0.....................................................................................
manuals comments on.................................................................
midplane.....................................................................................
10 description.........................................................................
functions............................................................................
midplane energy hazard warning...................................
modal dispersion in fiber-optic cable..............................
mode loss, higher-order........................................................
multimode fiber-optic cable See cables, fiber-optic
N
NEBS standards.....................................................................
O
open-frame rack See rack operating temperature warning.....................................
overview router.....................................................................................
P
parentheses, in syntax descriptions...............................
PC card, inserting...................................................................
PC card, removing.................................................................
physical specifications.........................................................
PIC
ATM, use of analyzer...................................................
cable installation instructions...................................
removal instructions..........................................
maintenance..................................................................
SONET/SDH alarm messages..................................................
analyzer, use of....................................................
276 status, checking............................................................
troubleshooting.............................................................
PICs..............................................................................................
connecting......................................................................
description........................................................................
replacing..........................................................................
status, checking...........................................................
ping command......................................................................
pinouts
DB-9 cable connector ports
(auxiliary/console)...................................................
RJ-45 Ethernet cable connector port....................
RJ-48 cable connector port.......................................
plug types
AC.......................................................................................
power budget calculation........................................................
cables and cords See AC power cord; DC power cables
disconnection warning (DC power).....................
margin calculation.........................................................
requirements for hardware components.............
surges.................................................................................
power supplies
AC electrical specifications.......................................
cables See DC power cable
DC electrical specifications......................................
LEDs..............................................................................
maintaining....................................................................
Copyright © 2015, Juniper Networks, Inc.
361
M320 Multiservice Edge Router Hardware Guide power system
AC electrical specifications.......................................
DC electrical specifications......................................
troubleshooting............................................................
powering off the router.......................................................
powering on the router........................................................
product disposal warning.................................................
Q
qualified personnel warning.............................................
R
rack clearance around, required..........................................
front-mount flange hole spacing.............................
mounting bracket hole spacing................................
securing to building.......................................................
size and strength required..........................................
standards, EIA and ETSI..............................................
rack mounting warning......................................................
radiation warning..................................................................
radio frequency interference, preventing.......................
ramp warning.........................................................................
redundancy..................................................................................
relative humidity, acceptable.............................................
removal instructions
alarm relay contact wires..........................................
cable auxiliary or console port (for Routing
Engine management)...................................
Ethernet port (for Routing Engine management)..................................................
PIC............................................................................
fuses..................................................................................
SFP.....................................................................................
XENPAK module..........................................................
removing
PC card.............................................................................
replacing
AC power supply cord................................................
air filters..........................................................................
CBs....................................................................................
CIP......................................................................................
craft interface.................................................................
DC power supply cord................................................
fan trays..........................................................................
FPCs..................................................................................
PICs...................................................................................
SIBs...................................................................................
requirements fire safety.........................................................................
restricted access warning..................................................
RFI (radio frequency interference)...................................
RJ-45 cable connector pinouts.........................................
RJ-48 cable connector pinouts.........................................
router
configuration..................................................................
installing with lift..........................................................
parts list............................................................................
physical specifications................................................
unpacking........................................................................
weight................................................................................
Routing Engine boot sequence................................................................
components.....................................................................
description.................................................................
,
LEDs.....................................................................................
maintaining....................................................................
management ports
cable and wire specifications...........................
ports on CIP
console port..............................................................
status indicator lights....................................................
taking offline...................................................................
USB port............................................................................
S
safety guidelines
electrical.........................................................................
general..............................................................................
safety standards....................................................................
safety warnings......................................................................
See also warnings
seismic (earthquake)............................................................
serial number in output from show chassis hardware
command..................................................................
SFP installation instructions.............................................
removal instructions....................................................
shipping crate repacking........................................................................
unpacking........................................................................
weight................................................................................
show chassis alarms command...........................
,
show chassis fpc command for FPC status...............................................................
show chassis fpc detail command...............................
362 Copyright © 2015, Juniper Networks, Inc.
Index
show chassis fpc pic-status command.......................
show chassis hardware command...............................
SIBs
components.....................................................................
79 description........................................................................
LEDs...............................................................................
,
maintaining....................................................................
replacing.........................................................................
signal dispersion......................................................................
signaling, distance limitations...........................................
single-mode fiber-optic cable See cables, fiber-optic site
electrical wiring guidelines.........................................
environmental specifications....................................
preparation checklist...................................................................
small form-factor pluggable See SFP
SONET/SDH analyzer, use of...........................................
specifications
AC power cord...............................................................
cable....................................................................................
power........................................................................
Routing Engine management ports..............
clearance around rack...................................................
electrical..........................................................................
environmental.................................................................
power drawn by hardware components...................
power system..................................................................
rack connection to building structure.....................
front-mount flange hole spacing....................
mounting bracket hole spacing.......................
size and strength...................................................
thermal output...............................................................
wires to external alarm-reporting devices...........
standards compliance........................................................
startup, system monitoring.......................................................................
status indicator lights for Routing Engine.......................
support, technical See technical support
surge protection......................................................................
Switch Interface Boards See SIBs
syntax conventions..............................................................
T
taking components offline
FPCs.....................................................................................
taking host subsystem offline..........................................
technical support
contacting JTAC...........................................................
telco rack See rack
temperature, acceptable range.........................................
93 thermal output........................................................................
93 tolerances..................................................................................
tools required chassis
returning for repair or replacement.............
hardware components
returning for repair or replacement.............
replacement...................................................................
traceroute command..........................................................
transmission distances, fiber-optic cable......................
troubleshooting
CLI commands.............................................................
cooling system..............................................................
fans....................................................................................
FPCs.................................................................................
fuses.................................................................................
PIC......................................................................................
power system................................................................
U
U (rack unit)..............................................................................
unpacking the router............................................................
W
warnings
battery handling...........................................................
Class 1 laser....................................................................
Class 1 LED......................................................................
copper conductors (DC power).............................
electrical..........................................................................
grounding........................................................................
grounding equipment ................................................
installation.....................................................................
jewelry removal............................................................
laser and LED.................................................................
laser beam......................................................................
levels defined.................................................................
lightning activity...........................................................
maintenance and operational................................
midplane energy hazard ..........................................
343 multiple power supplies disconnection..............
operating temperature..............................................
power disconnection.................................................
power removal.............................................................
Copyright © 2015, Juniper Networks, Inc.
363
M320 Multiservice Edge Router Hardware Guide product disposal..........................................................
qualified personnel......................................................
rack mounting...............................................................
radiation..........................................................................
ramp.................................................................................
restricted access...........................................................
wiring terminations (DC power)............................
wavelength ranges supported by fiber-optic cable.........................................................................................
wiring electrical See electricity
terminations warning (DC power)........................
X
XENPAK module...................................................................
installation instructions............................................
removal instructions...................................................
364 Copyright © 2015, Juniper Networks, Inc.
ดาวน์โหลด