Agilent U1401A Handheld Multi-function
Calibrator/Meter
Data Sheet
Calibrate while you measure with just one tool
Agilent U1401A handheld multi-function calibrator/meter has all you need for quick validation, servicing or troubleshooting of process control devices on the go. Travel and test easily with one rugged, featurepacked tool.
Features
Dual display with bright LCD backlight
Simultaneous source and measure
Bipolar voltage and current,
square-wave, auto scan and
ramp outputs
Full-span DMM capability, including
temperature and frequency
measurements
Hold and Min/Max/Average recordings
Data logging to PC with optional
IR-to-USB cable
Built-in charging capability
The 2-in-1 that helps you travel light
More often than not, the calibration of process control parts requires simultaneous measurements with a DMM. With the
U1401A, you can carry two tools in one and calibrate while you measure. Slip the
U1401A in its sturdy carrying case and youre ready to go.
Full-featured DMM functions
The U1401A is packed with a full span of
DMM measurement functions, including
AC+DC voltage and current, resistance, temperature, frequency, diode and continuity tests. It also equips you with recording functions such as Hold, Min/Max/Average and data logging to PC.
Rugged and tested to stringent standards
The U1401A comes with a robust protective holster and tested to stringent industrial standards. Each U1401A is also sealed with a three-year warranty and the assurance that you can perform your calibration tasks with confidence.
Amplicon.com
IT and Instrumentation for industry
Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: [email protected]
Datasheet
Take a closer look
Robust protective holster
Hold and Min/Max/Avg recordings
Built-in batterycharging capability
Bipolar voltage and current, square-wave, auto scan and ramp
Dual display with backlight
4-20 mA and 0-20 mA percentage scale readout
Easy function access through intuitive buttons and rotary switch
Simultaneous source and measure
Voltage, current, resistance, temperature, frequency, pulse width, duty cycle, diode and continuity
Amplicon.com
IT and Instrumentation for industry
Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: [email protected]
Datasheet
Input Specifications
The accuracy is given as ± (% of reading + counts of least significant digit (LSD)) at 23 °C ±
5 °C, with relative humidity less than 80% R.H., and after a warm-up period of at least five minutes.
Without warm-up, an additional five counts of LSD need to be considered.
Voltage specifications
Function
DC voltage [1]
Range
50 mV
500 mV
5 V
50 V
250 V
Resolution
1 µV
10 µV
0.1 mV
1 mV
10 mV
Accuracy
0.05% + 50 [2]
0.03% + 5
AC voltage [3]
(True-rms: From 5% to
100% of range)
50 mV 1 µV
45 Hz to 5 kHz: 0.7% + 40
5 kHz to 20 kHz: 1.5% + 40
500 mV
5 V
50 V
250 V
10 µV
0.1 mV
1 mV
10 mV
45 Hz to 5 kHz: 0.7% + 20
5 kHz to 20 kHz: 1.5% + 20
AC+DC voltage [3]
(True-rms: From 5% to
100% of range)
50 mV 1 µV
45 Hz to 5 kHz: 0.8% + 70
5 kHz to 20 kHz: 1.6% + 70
500 mV
5 V
50 V
250 V
10 µV
0.1 mV
1 mV
10 mV
45 Hz to 5 kHz: 0.8% + 25
5 kHz to 20 kHz: 1.6% + 25
Overload protection
250 Vrms
[1] Input impedance: 10 MW (nominal) for the range of 5 V and above, and 1 GW (nominal) for the 50/500 mV range.
[2] Accuracy can be improved to 0.05% + 5. Always use the Relative function to offset thermal effects before measuring the signal.
[3] Input impedance: 1.1 MW in parallel with <100 pF (nominal) for the range of 5 V and above, and 1 GW (nominal) for the 50/500 mV range. Crest factor ~ 3.
Amplicon.com
IT and Instrumentation for industry
Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: [email protected]
Datasheet
Current specifications
Function
DC current
AC current [2]
(True-rms: From 5% to 100% of range)
AC+DC current [2]
(True-rms: From 5% to 100% of range)
Range
50 mA
500 mA
50 mA
500 mA
50 mA
500 mA
Resolution
1 µA
10 µA
1 µA
10 µA
1 µA
10 µA
Accuracy
0.03% + 5 [1]
45 Hz to 5 kHz:
0.6% + 20
45 Hz to 5 kHz:
0.7% + 25
Burden voltage/shunt Overload protection
0.06 V (1 W)
0.6 V (1 W)
0.06 V (1 W)
0.6 V (1 W) 250 V, 630 mA
Quick acting fuse
0.06 V (1 W)
0.6 V (1 W)
[1] Always use the Relative function to offset thermal effects before measuring the signal. If this function is not used, accuracy
could go down to 0.03% + 25. Thermal effects may be present due to:
Constant current, constant voltage, or square wave output.
Wrong operation. For example, resistance, diode, or mV measurement function is used to measure high voltage signals exceeding 250 V.
After battery charging has completed.
After measuring current greater than 50 mA.
[2] Crest factor ~ 3
Amplicon.com
IT and Instrumentation for industry
Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: [email protected]
Datasheet
Temperature specifications
Thermocouple type
K
Range
40 °C to 1372 °C
40 °F to 2502 °F
Resolution
0.1 °C
0.1 °F
Accuracy [1]
0.3% + 3 °C
0.3% + 6 °F
Overload protection
250 Vrms
Resistance specifications
The following resistance specifications are valid if the maximum open voltage is less than +4.8 V.
Range
500 W
5 kW
50 kW
500 kW
5 MW
50 MW
Resolution
0.01 W
0.1 W
1 W
10 W
0.1 kW
1 kW
Accuracy
0.15% + 8 [2]
0.15% + 5 [2]
1% + 8 [3]
Minimum input current
0.45 mA
0.45 mA
45 µA
4.5 µA
450 nA
45 nA
Diode and continuity specifications
For diode test, the overload protection is 250 Vrms and the instrument will beep when the reading is below 50 mV (approx). For continuity test, the instrument will beep when the resistance is less than 10.00 W.
Resolution
0.1 mV
Accuracy
0.05% + 5
Test current
Approximately 0.45 mA
Open voltage
< +4.8 VDC
1 ms peak hold specifications
Signal width
Single event >1 ms
Accuracy for DC mV/voltage/current
2% + 400 for all ranges
Overload protection
250 V rms
[1] Accuracy is specified for meter operation only, excludes thermocouple probe tolerance and with the instrument placed in the operating area for at least one hour.
[2] Accuracy is specified after applying the Relative function to offset any test lead resistance and thermal effect.
[3] Accuracy is specified for <60% R.H.
Amplicon.com
IT and Instrumentation for industry
Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: [email protected]
Datasheet
Frequency specifications
Range
100 Hz
1 kHz
10 kHz
100 kHz
200 kHz
Resolution
0.001 Hz
0.01 Hz
0.1 Hz
1 Hz
10 kHz
Accuracy
0.02% + 3
Minimum input frequency
1 Hz
Frequency sensitivity and trigger level for voltage measurement
Input range Minimum sensitivity
(rms sine wave)
50 mV
500 mV
5 V
50 V
250 V
1 Hz to 100 kHz
15 mV
35 mV
0.3 V
3V
30 V
>100 kHz
25 mV
50 mV
0.5 V
5 V
<20 kHz
20 mV
60 mV
0.6 V
6 V
60 V
Overload protection
250 Vrms
Trigger level for DC coupling
20 kHz to 200 kHz
30 mV
80 mV
0.8 V
8 V
Frequency sensitivity for current measurement
Input range
50 mA
500 mA
Minimum sensitivity (rms sine wave)
30 Hz to 20 kHz
2.5 mA
25 mA
Duty cycle and pulse width
Function
Duty cycle
Pulse width [2]
Mode
DC coupling
AC coupling
Range
0.1% to 99.9%
5% to 95%
0.01 ms to 1999.9 ms
[1] Accuracy is based on a 5-V square-wave input to the 5 VDC range.
[2] Pulse width must be greater than 10 µs and its range is determined by the frequency of the signal.
Accuracy at full scale [1]
0.3% per kHz + 0.3%
0.2% + 3
Amplicon.com
IT and Instrumentation for industry
Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: [email protected]
Datasheet
Output Specifications
Accuracy is given as ± (% of output + counts of least significant digit (LSD)) at 23 °C ± 5 °C, with relative humidity less than 80% R.H., and after a warm-up period of at least five minutes.
The maximum input voltage protection is 30 VDC.
Constant voltage and current outputs
Function
Constant voltage (CV)
Constant current (CC)
Range
± 1.500 V
± 15.000 V
± 25.000 mA
Resolution
0.1 mV
1 mV
1 µA
Accuracy
0.03% + 3
0.03% + 5
Minimum output
25 mA or above [1]
12 V or above [2][3]
Square wave output
Output
Frequency (Hz)
Duty Cycle (%) [4]
Pulse Width (ms)
Amplitude (V)
[4]
Range
0.5, 1, 2, 5, 10, 15, 20, 25, 30, 40, 50, 60, 75,
80, 100, 120, 150, 200, 240, 300, 400, 480,
600, 800, 1200, 1600, 2400, 4800
0.39% to 99.60%
1/Frequency
5 V, 12 V
±5 V, ±12 V
Resolution
0.01
0.390625%
Range/256
0.1 V
Accuracy
0.005% + 1
0.01% + 0.2% [5]
0.01% + 0.3 ms
2% + 0.2 V
2% + 0.4 V
[1] Loading coefficient: 0.012 mV/mA for 1.5 V output.
[2] Loading coefficient: 1 µA/ V. The minimum output voltage is based on 20 mA into a 600 W load.
[3] If the current loop has a 24-V power, a minimum output voltage of 24 V is achievable with a 20 mA current into a 1200-W load (using the yellow test lead).
[4] The positive or negative pulse width must be greater than 50 µs to enable adjustment of duty cycle or pulse width under different frequencies. Otherwise, the accuracy and range will
be different from the specifications defined.
[5] For signal frequencies greater than 1 kHz, add an addition of 0.1% per kHz.
Amplicon.com
IT and Instrumentation for industry
Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: [email protected]
Datasheet
General Specifications
Display
Power supply
Power consumption
Battery life
Charging time
Measurement rate
Common Mode Rejection Ratio (CMRR)
Normal Mode Rejection Ratio (NMRR)
Operating environment
Storage environment
Altitude
Safety compliance
EMC compliance
Temperature coefficient
Dimensions (H x W x D)
Weight
Calibration
Warranty
Both primary and secondary displays are 5-digit on the liquid crystal display (LCD) with a maximum resolution of 51,000 counts and automatic polarity indication. Backlight available.
9.6 V Ni-MH rechargeable batteries: 1.2 V x 8 pieces. No cadmium, lead or mercury.
External switching adapter: AC 100 V to 240 V, 50/60 Hz input and DC 24 V/2.5 A output
Battery charging: 9.3 VA typical
Sourcing of constant current at 25 mA, maximum load: 5.5 VA typical on 24 V DC adapter,
2.4 VA typical on 9.6 V batteries
Meter only: 1.8 VA typical on 24 V DC adapter, 0.6 VA typical on 9.6 V batteries
Assuming fully-charged Ni-MH batteries:
Meter only: 20 hours (approx.)
Source/Meter: 4 hours (approx.)
will appear when voltage drops below 9 V (approx.)
3 hours (approx.) in 10 °C to 30 °C environment
NOTE: Prolonged charging is required if battery is fully discharged.
3 readings/second, except for:
AC+DC: 1 reading/second
Frequency and duty cycle (> 1 Hz): 1 reading/second
Pulse width (> 1 Hz): 0.25 to 1 reading/second
> 90 dB at DC, 50/60 Hz ± 0.1% (1 kW unbalanced)
> 60 dB at DC, 50/60 Hz ± 0.1%
0 °C to 40 °C; up to 80% relative humidity (R.H.) for temperatures up to 31 °C, decreasing linearly to 50% R.H. at 40 °C
20 °C to 60 °C with batteries removed; 5% to 80% R.H. non-condensing
0 to 2000 m
IEC 61010-1:2001/EN61010-1:2001 (2nd Edition), CAN/CSA-C22.2 No. 61010-1-04,
ANSI/UL 61010-1:2004, CAT II 150 V Overvoltage Protection, Pollution Degree 2
IEC61326-2-1:2005/EN61326-2-1:2006, ICES-001:2004, AS/NZS CISPR11:2004
Input: 0.15 x (specified accuracy)/°C (from 0 °C to 18 °C or 28 °C to 40 °C)
Output: ±(50 ppm output + 0.5 digit)/°C
192 mm x 90 mm x 54 mm
0.98 kg with holster and batteries
One-year calibration cycle recommended
3 years for main unit
3 months for standard accessories unless otherwise specified
Amplicon.com
IT and Instrumentation for industry
Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: [email protected]