IMC Networks McBasic TX/FX -30, -40, -50 network media converter Installation Guide
PDF
Документ
Реклама
Реклама
OTHER PERSON, INCLUDING EMPLOYEES, DISTRIBUTORS, RESELLERS OR DEALERS OF IMC NETWORKS, WHICH ARE INCONSISTENT WITH THE WARRANTY SET FORTH ABOVE. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED TO THE DURATION OF THE EXPRESS WARRANTY STATED ABOVE. Every reasonable effort has been made to ensure that IMC Networks product manuals and promotional materials accurately describe IMC Networks product specifications and capabilities at the time of publication. However, because of ongoing improvements and updating of IMC Networks products, IMC Networks cannot guarantee the accuracy of printed materials after the date of publication and disclaims liability for changes, errors or omissions. FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class A computing device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own expense. Any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. The use of non-shielded I/O cables may not guarantee compliance with FCC RFI limits. This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada. Installation Guide McBasic TX/FX Q U I C K S T A R T Introduction About McBasic TX/FX Installation McBasic TX/FX™ is a low-cost, IEEE 802.3 sin- Configuration gle-conversion media converter that converts Crossover/Pass-Through between 100Base-TX twisted pair and LinkLoss & FiberAlert 100Base-FX multi-mode or single-mode fiber. Auto-Negotiation It is available with one RJ-45 connector for the twisted pair port and several types of fiber con- LED Indicators Tech Support nectors, including ST, SC, MT and LC, for the Warranty/Safety Certifications fiber port. McBasic TX/FX is a 1U high, stand alone unit that includes diagnostic LEDs for each port and a universal (100/240 VAC) power supply. SAFETY CERTIFICATIONS UL: CE: Listed to UL1950 and CSA 22.2, No. 950, Safety of Information Technology Equipment, Including Electrical Business Equipment. The products described herein comply with the Council Directive on Electromagnetic Compatibility (89/336/EEC) and the Council Directive on Electrical Equipment Designed for use within Certain Voltage Limits (73/23/EEC). Certified to EN 60950, Safety of Information Technology Equipment, Including Electrical Business Equipment. For further details, contact IMC Networks. Installing McBasic TX/FX Questions or Comments about this manual? Contact [email protected]. Configuring McBasic TX/FX Before installation, configure McBasic TX/FX for the following features: • TX LinkLoss • FX LinkLoss 19772 Pauling • Foothill Ranch, CA 92610-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetworks.com Once installed, configure McBasic TX/FX for the following features: • FiberAlert • Auto-Negotiation © 2001-2003 IMC Networks. All rights reserved. The information in this document is subject to change without notice. IMC Networks assumes no responsibility for any errors that may appear in this document. McBasic is a trademark of IMC Networks. Other brands or product names may be trademarks and are the property of their respective companies. Document Number 55-80126-03 A1 McBasic TX/FX comes ready to install (with the exception of configuring certain features, if desired – see below). To install McBasic TX/FX, first make sure that the unit is placed on a suitable flat surface. Attach the cables between the McBasic TX/FX and each device that will be interconnected, then plug the unit into a reliable, filtered power source. NOTE: The default for all featuers is Disabled. April 2003 8 1 1 1 1 4 2 5 6 6 7 TWISTED PAIR CROSSOVER/PASS-THROUGH CONNECTIONS Whether you are using crossover or straight-through CAT5 twisted pair cabling, McBasic TX/FX will support both types of connections by one of the following methods: AutoCross: McBasic TX/FX (-50) includes AutoCross, a feature which automatically selects between a crossover workstation or pass-through/ repeater hub connection depending on the connected device. NOTE: The MDI/MDI-X button is NOT required on this model. MDI/MDI-X Switch: McBasic TX/FX (-30 and -40) feature a push button switch, located next to the RJ-45 connector, for selecting the type of connection. A pass-through connection is selected when the push-button is pushed IN. To select a crossover connection the button should be in the OUT position. If you are unsure of the type of connection, set the push button to a position that makes the twisted pair LNK (link) LED glow. About FiberAlert and LinkLoss McBasic TX/FX comes with the following troubleshooting features: • FX LinkLoss (a.k.a. "Fiber LinkLoss" or "LinkLoss") • TX LinkLoss (a.k.a. "Twisted Pair LinkLoss” or "Reverse LinkLoss”) • FiberAlert LinkLoss and FiberAlert are advanced troubleshooting features that can help you locate "silent failures" on your network. However, it is vital that you understand exactly how FiberAlert and LinkLoss work, and how they will react in your network configuration, before attempting to install the enclosed module(s). FIBER OPTIC CLEANING GUIDELINES Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, which can obstruct the optic path and cause performance degradation. Good system performance requires clean optics and connector ferrules. 1) Use fiber patch cords (or connectors, if you terminate your own fiber) only from a reputable supplier; low-quality components can cause many hard-to-diagnose problems in an installation. 2) Dust caps are installed at IMC Networks to ensure factory-clean optical devices. These protective caps should not be removed until the moment of connecting the fiber cable to the device. Assure that the fiber is properly terminated, polished and free of any dust or dirt, and that the location is as free from dust and dirt as possible. 3) Store spare caps in a dust-free environment such as a sealed plastic bag or box so that when reinstalled they do not introduce any contamination to the optics. 4) Should it be necessary to disconnect the fiber device, reinstall the protective dust caps. 5) If you suspect that the optics have been contaminated, alternate between blasting with clean, dry, compressed air and flushing with methanol to remove particles of dirt. ELECTROSTATIC DISCHARGE PRECAUTIONS Electrostatic discharge (ESD) can cause damage to your add-in modules. Always observe the following precautions when installing or handling an add-in module or any board assembly. 1) Do not remove unit from its protective packaging until you’re ready to install it. 2) Wear an ESD wrist grounding strap before handling any module or component. If you do not have a wrist strap, maintain grounded contact with the system unit throughout any procedure requiring ESD protection. WARNING! Integrated circuits and fiber optic components are extremely susceptible to electrostatic discharge damage. Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices. 3) Hold boards by the edges only; do not touch the electronic components or gold connectors. 4) After removal, always place the boards on a grounded, static-free surface, ESD pad or in a proper ESD bag. Do not slide the board over any surface. WARRANTY During normal operation, link integrity pulses are transmitted by all point-to-point Ethernet devices. When an IMC Networks media converter receives valid link pulses, it knows that the device to which it is connected is up and sending pulses, and that the copper or fiber cable coming from that device is intact. The appropriate “LINK” LED is lit to indicate this. The IMC Networks media converter also sends out link pulses from its IMC Networks warrants to the original end-user purchaser that this product, EXCLUSIVE OF SOFTWARE, shall be free from defects in materials and workmanship under normal and proper use in accordance with IMC Networks' instructions and directions for a period of six (6) years after the original date of purchase. This warranty is subject to the limitations set forth below. At its option, IMC Networks will repair or replace at no charge the product which proves to be defective within such warranty period. This limited warranty shall not apply if the IMC Networks product has been damaged by unreasonable use, accident, negligence, service or modification by anyone other than an authorized IMC Networks Service Technician or by any other causes unrelated to defective materials or workmanship. Any replaced or repaired products or parts carry a ninety (90) day warranty or the remainder of the initial warranty period, whichever is longer. To receive in-warranty service, the defective product must be received at IMC Networks no later than the end of the warranty period. The product must be accompanied by proof of purchase, satisfactory to IMC Networks, denoting product serial number and purchase date, a written description of the defect and a Return Merchandise Authorization (RMA) number issued by IMC Networks. No products will be accepted by IMC Networks which do not have an RMA number. For an RMA number, contact IMC Networks at PHONE: (800) 624-1070 (in the U.S and Canada) or (949) 465-3000 or FAX: (949) 465-3020. The enduser shall return the defective product to IMC Networks, freight, customs and handling charges prepaid. End-user agrees to accept all liability for loss of or damages to the returned product during shipment. IMC Networks shall repair or replace the returned product, at its option, and return the repaired or new product to the end-user, freight prepaid, via method to be determined by IMC Networks. IMC Networks shall not be liable for any costs of procurement of substitute goods, loss of profits, or any incidental, consequential, and/or special damages of any kind resulting from a breach of any applicable express or implied warranty, breach of any obligation arising from breach of warranty, or otherwise with respect to the manufacture and sale of any IMC Networks product, whether or not IMC Networks has been advised of the possibility of such loss or damage. EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE, IMC NETWORKS MAKES NO OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, WITH RESPECT TO THIS IMC NETWORKS PRODUCT, INCLUDING WITHOUT LIMITATION ANY SOFTWARE ASSOCIATED OR INCLUDED. IMC NETWORKS SHALL DISREGARD AND NOT BE BOUND BY ANY REPRESENTATIONS OR WARRANTIES MADE BY ANY 2 7 Installing modules without understanding the effects of LinkLoss and FiberAlert can cause perfectly functioning units to appear flawed or even dead. If you are unfamiliar with LinkLoss and FiberAlert, IMC Networks strongly encourages you to read the following information. Contact IMC Networks technical support at (800) 624-1070 (U.S. and Canada), +32-16-550880 (Europe) or [email protected] for more information/assistance. ABOUT LINK INTEGRITY • To test McBasic TX/FX by itself, you must have an appropriate fiber patch cable. First, connect McBasic TX/FX to the twisted pair device with a twisted pair cable. Next, loop a single strand of fiber from the transmit port to the receive port of your media converter. Finally, verify that you have both twisted pair and fiber link on your media converter. • If attempting to use a high powered device (which is designed for long distance installations) for a short distance installation, the fiber transmitters may overdrive the receivers and cause data loss. If this is the case, you may need to add an optical attenuator to your connection. Please visit our Web site at www.imcnetworks.com/adocs/fcs.asp for fiber specifications, or contact IMC Networks for more information. LED Indicators Glows Glows Glows Glows WHAT IS FX LINKLOSS? FX LinkLoss is a troubleshooting feature. When a fault occurs on the fiber segment of a conversion, FX LinkLoss detects the fault and passes this information to the twisted pair segment. If a media converter is not receiving a fiber link, FX LinkLoss disables the transmitter on the media converter's twisted pair port. This results in a loss of link on the device connected to the twisted pair port. WHAT IS TX LINKLOSS? McBasic TX/FX features four diagnostic LEDs. The functions are: FX RCV TX LNK FA FX LNK copper and fiber transmitters, but normally has no way of knowing whether the cable to the other device is intact and the link pulses are reaching the other end. FiberAlert and LinkLoss allow this information to be obtained from the fiber, even when physical access to a remote device (and its link integrity LED) is not available. yellow when module is receiving data. green when a twisted pair link is established. green when FiberAlert is enabled. green when a fiber link is established. TX LinkLoss is another troubleshooting feature. When a fault occurs on the twisted pair segment of a conversion, TX LinkLoss detects the fault and passes this information to the fiber segment. If a media converter is not receiving a twisted pair link, TX LinkLoss disables the transmitter on the media converter's fiber port. This results in a loss of link on the device connected to the fiber port. Local Site Cable Break XMT General Information WHAT IS FIBERALERT? Remote Site RCV RCV FiberAlert minimizes the problems associated with the loss of one strand of fiber. IMC Networks product with FiberAlert enabled — If a strand is unavailable, the IMC Networks Remote Site stops transmitting Local Link LED is OFF indicating a break in the fiber loop device at the receiver end notes the loss of link. The device will then stop transmitting data and the link signal until a signal or link pulse is received. The result is that the link LED on BOTH sides of the fiber connection will go out indicating a fault somewhere in the fiber loop. Using FiberAlert, a local site administrator is notified of a fault and can quickly determine where a cable fault is located. (To enable, see page 4). LED IMC NETWORKS TECHNICAL SUPPORT TEL: (949) 465-3000; (800) 624-1070 (in the U.S and Canada); +32-16-550880 (Europe) FAX: (949) 465-3020 E-M Mail: [email protected] Web: www.imcnetworks.com SPECIFICATIONS Environmental Operating Temperature: 32° - 104° F (0° - 40° C) Storage Temperature: 0° - 160° F (-20° - 70° C) Humidity: 5 - 95% (non-condensing) Power AC Input Load: 100/240V±10% ~ 50/60 Hz, 0.1/0.05A Heat generated: 25 BTU/hr. Dimensions 1.50”H x 4.65”W x 4.43”D (3.8 cm x 11.8 cm x 11.3 cm) 1.3 lbs. (0.6 kg) Fiber Optic Specifications For fiber optic specifications, please visit our Web site at: http://www.imcnetworks.com/adocs/fcs.asp 6 XMT LED OFF = Broken Link LED FiberAlert should only be enabled on ONE side of a media conversion. Enabling it on both sides would keep both transmitters off indefinitely. USING FIBERALERT AND LINKLOSS The following table provides an overview of the troubleshooting features, their functionality and the recommended settings for a pair of media converters in a typical central/main site to remote site application: L I N K L O S S / F I B E R A L E R T C O M P A R I S O N T A B L E Feature Fault Location Disabled LEDs Enable At: FX LinkLoss Fiber Twisted Pair Main Site Only TX LinkLoss Twisted Pair Fiber Remote Site Only FiberAlert Fiber Fiber Remote Site Only 3 This will ensure that any faults, no matter where they occur, can be detected by an administrator located at the central site. For more information, please visit www.imcnetworks.com/tech/ref-ffeatures.asp. If you are unsure of how best to implement these features in your configuration, please contact IMC Networks technical support at (800) 624-1070 (U.S. and Canada), +32-16-550880 (Europe) or via e-mail at: [email protected]. ENABLING TX AND ENABLING FIBERALERT Configure FiberAlert on McBasic TX/FX by adjusting a two-position switch, labeled FA, on the faceplate next to the fiber connectors. Enable this feature by moving the switch to the up (ON) position. Disable (default) by moving the switch to the down (OFF) position. Auto-Negotiation on McBasic TX/FX FX LINKLOSS In order to enable the LinkLoss features, you will need to remove the cover from the unit and place the jumpers accordingly. Follow the instructions below, referencing the diagram on the opposite page: 1) Make sure that there is no power going to the unit by UNPLUGGING THE POWER CORD! 2) Using a Phillips screwdriver, remove the screws on the corners of the cover. 3) Remove the cover and find the three-pin jumper blocks for TX and FX LinkLoss. Adjust the shunts on the jumpers according to your requirements. See diagrams/chart below for jumper location and settings. 4) Replace the cover and tighten the screw to secure the cover. Auto-Negotiation is available on McBasic TX/FX. When Auto-Negotiation is enabled, the media converter negotiates as a 100 Mbps Full-Duplex device; if the device the McBasic TX/FX is connected to can operate at 100 Mbps Full-Duplex, a link will be established. If the twisted pair port on the other device does not have the ability to auto-negotiate, or if a 100 Mbps Half-Duplex connection is desired, AutoNegotiation on McBasic TX/FX must be disabled. Half- and Full-Duplex settings must be manually set and match on both devices to which McBasic TX/FX is connected. The diagram below shows a typical application, followed by a table with three possible configurations. ENABLING AUTO-NEGOTIATION TX/FX -30 Configure Auto-Negotiation on McBasic TX/FX by adjusting a two-position switch, labeled AN, on the faceplate next to the fiber connectors. Enable this feature by moving the switch to the up (ON) position. Disable (default) by moving the switch to the down (OFF) position. TX/FX -40 3 1 2 3 1 2 3 Note: PIN # 1 2 3 Note: PIN # Note: PIN # 4 2 3 Note: PIN # Board Feature Jumpers JP1 -30 FX LL TX LL JP2 JP2 -40 TX LL FX LL JP3 JP1 -50 TX LL FX LL JP2 Deafult is OFF for all features TX/FX -50 1 ON 1-2 1-2 1-2 1-2 1-2 1-2 OFF 2-3 2-3 2-3 2-3 2-3 2-3 If you are unsure of how best to implement these features in your configuration, please contact IMC Networks Technical Support at (800) 624-1070 (U.S. and Canada); +32-16-550880 (Europe). Installation Troubleshooting • During installation, test your fiber and twisted pair connections with FiberAlert disabled. Then enable FiberAlert, if desired, just before final installation. This will reduce the feature’s interference with testing. 5 This will ensure that any faults, no matter where they occur, can be detected by an administrator located at the central site. For more information, please visit www.imcnetworks.com/tech/ref-ffeatures.asp. If you are unsure of how best to implement these features in your configuration, please contact IMC Networks technical support at (800) 624-1070 (U.S. and Canada), +32-16-550880 (Europe) or via e-mail at: [email protected]. ENABLING TX AND ENABLING FIBERALERT Configure FiberAlert on McBasic TX/FX by adjusting a two-position switch, labeled FA, on the faceplate next to the fiber connectors. Enable this feature by moving the switch to the up (ON) position. Disable (default) by moving the switch to the down (OFF) position. Auto-Negotiation on McBasic TX/FX FX LINKLOSS In order to enable the LinkLoss features, you will need to remove the cover from the unit and place the jumpers accordingly. Follow the instructions below, referencing the diagram on the opposite page: 1) Make sure that there is no power going to the unit by UNPLUGGING THE POWER CORD! 2) Using a Phillips screwdriver, remove the screws on the corners of the cover. 3) Remove the cover and find the three-pin jumper blocks for TX and FX LinkLoss. Adjust the shunts on the jumpers according to your requirements. See diagrams/chart below for jumper location and settings. 4) Replace the cover and tighten the screw to secure the cover. Auto-Negotiation is available on McBasic TX/FX. When Auto-Negotiation is enabled, the media converter negotiates as a 100 Mbps Full-Duplex device; if the device the McBasic TX/FX is connected to can operate at 100 Mbps Full-Duplex, a link will be established. If the twisted pair port on the other device does not have the ability to auto-negotiate, or if a 100 Mbps Half-Duplex connection is desired, AutoNegotiation on McBasic TX/FX must be disabled. Half- and Full-Duplex settings must be manually set and match on both devices to which McBasic TX/FX is connected. The diagram below shows a typical application, followed by a table with three possible configurations. ENABLING AUTO-NEGOTIATION TX/FX -30 Configure Auto-Negotiation on McBasic TX/FX by adjusting a two-position switch, labeled AN, on the faceplate next to the fiber connectors. Enable this feature by moving the switch to the up (ON) position. Disable (default) by moving the switch to the down (OFF) position. TX/FX -40 3 1 2 3 1 2 3 Note: PIN # 1 2 3 Note: PIN # Note: PIN # 4 2 3 Note: PIN # Board Feature Jumpers JP1 -30 FX LL TX LL JP2 JP2 -40 TX LL FX LL JP3 JP1 -50 TX LL FX LL JP2 Deafult is OFF for all features TX/FX -50 1 ON 1-2 1-2 1-2 1-2 1-2 1-2 OFF 2-3 2-3 2-3 2-3 2-3 2-3 If you are unsure of how best to implement these features in your configuration, please contact IMC Networks Technical Support at (800) 624-1070 (U.S. and Canada); +32-16-550880 (Europe). Installation Troubleshooting • During installation, test your fiber and twisted pair connections with FiberAlert disabled. Then enable FiberAlert, if desired, just before final installation. This will reduce the feature’s interference with testing. 5 • To test McBasic TX/FX by itself, you must have an appropriate fiber patch cable. First, connect McBasic TX/FX to the twisted pair device with a twisted pair cable. Next, loop a single strand of fiber from the transmit port to the receive port of your media converter. Finally, verify that you have both twisted pair and fiber link on your media converter. • If attempting to use a high powered device (which is designed for long distance installations) for a short distance installation, the fiber transmitters may overdrive the receivers and cause data loss. If this is the case, you may need to add an optical attenuator to your connection. Please visit our Web site at www.imcnetworks.com/adocs/fcs.asp for fiber specifications, or contact IMC Networks for more information. LED Indicators Glows Glows Glows Glows WHAT IS FX LINKLOSS? FX LinkLoss is a troubleshooting feature. When a fault occurs on the fiber segment of a conversion, FX LinkLoss detects the fault and passes this information to the twisted pair segment. If a media converter is not receiving a fiber link, FX LinkLoss disables the transmitter on the media converter's twisted pair port. This results in a loss of link on the device connected to the twisted pair port. WHAT IS TX LINKLOSS? McBasic TX/FX features four diagnostic LEDs. The functions are: FX RCV TX LNK FA FX LNK copper and fiber transmitters, but normally has no way of knowing whether the cable to the other device is intact and the link pulses are reaching the other end. FiberAlert and LinkLoss allow this information to be obtained from the fiber, even when physical access to a remote device (and its link integrity LED) is not available. yellow when module is receiving data. green when a twisted pair link is established. green when FiberAlert is enabled. green when a fiber link is established. TX LinkLoss is another troubleshooting feature. When a fault occurs on the twisted pair segment of a conversion, TX LinkLoss detects the fault and passes this information to the fiber segment. If a media converter is not receiving a twisted pair link, TX LinkLoss disables the transmitter on the media converter's fiber port. This results in a loss of link on the device connected to the fiber port. Local Site Cable Break XMT General Information WHAT IS FIBERALERT? Remote Site RCV RCV FiberAlert minimizes the problems associated with the loss of one strand of fiber. IMC Networks product with FiberAlert enabled — If a strand is unavailable, the IMC Networks Remote Site stops transmitting Local Link LED is OFF indicating a break in the fiber loop device at the receiver end notes the loss of link. The device will then stop transmitting data and the link signal until a signal or link pulse is received. The result is that the link LED on BOTH sides of the fiber connection will go out indicating a fault somewhere in the fiber loop. Using FiberAlert, a local site administrator is notified of a fault and can quickly determine where a cable fault is located. (To enable, see page 4). LED IMC NETWORKS TECHNICAL SUPPORT TEL: (949) 465-3000; (800) 624-1070 (in the U.S and Canada); +32-16-550880 (Europe) FAX: (949) 465-3020 E-M Mail: [email protected] Web: www.imcnetworks.com SPECIFICATIONS Environmental Operating Temperature: 32° - 104° F (0° - 40° C) Storage Temperature: 0° - 160° F (-20° - 70° C) Humidity: 5 - 95% (non-condensing) Power AC Input Load: 100/240V±10% ~ 50/60 Hz, 0.1/0.05A Heat generated: 25 BTU/hr. Dimensions 1.50”H x 4.65”W x 4.43”D (3.8 cm x 11.8 cm x 11.3 cm) 1.3 lbs. (0.6 kg) Fiber Optic Specifications For fiber optic specifications, please visit our Web site at: http://www.imcnetworks.com/adocs/fcs.asp 6 XMT LED OFF = Broken Link LED FiberAlert should only be enabled on ONE side of a media conversion. Enabling it on both sides would keep both transmitters off indefinitely. USING FIBERALERT AND LINKLOSS The following table provides an overview of the troubleshooting features, their functionality and the recommended settings for a pair of media converters in a typical central/main site to remote site application: L I N K L O S S / F I B E R A L E R T C O M P A R I S O N T A B L E Feature Fault Location Disabled LEDs Enable At: FX LinkLoss Fiber Twisted Pair Main Site Only TX LinkLoss Twisted Pair Fiber Remote Site Only FiberAlert Fiber Fiber Remote Site Only 3 TWISTED PAIR CROSSOVER/PASS-THROUGH CONNECTIONS Whether you are using crossover or straight-through CAT5 twisted pair cabling, McBasic TX/FX will support both types of connections by one of the following methods: AutoCross: McBasic TX/FX (-50) includes AutoCross, a feature which automatically selects between a crossover workstation or pass-through/ repeater hub connection depending on the connected device. NOTE: The MDI/MDI-X button is NOT required on this model. MDI/MDI-X Switch: McBasic TX/FX (-30 and -40) feature a push button switch, located next to the RJ-45 connector, for selecting the type of connection. A pass-through connection is selected when the push-button is pushed IN. To select a crossover connection the button should be in the OUT position. If you are unsure of the type of connection, set the push button to a position that makes the twisted pair LNK (link) LED glow. About FiberAlert and LinkLoss McBasic TX/FX comes with the following troubleshooting features: • FX LinkLoss (a.k.a. "Fiber LinkLoss" or "LinkLoss") • TX LinkLoss (a.k.a. "Twisted Pair LinkLoss” or "Reverse LinkLoss”) • FiberAlert LinkLoss and FiberAlert are advanced troubleshooting features that can help you locate "silent failures" on your network. However, it is vital that you understand exactly how FiberAlert and LinkLoss work, and how they will react in your network configuration, before attempting to install the enclosed module(s). FIBER OPTIC CLEANING GUIDELINES Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, which can obstruct the optic path and cause performance degradation. Good system performance requires clean optics and connector ferrules. 1) Use fiber patch cords (or connectors, if you terminate your own fiber) only from a reputable supplier; low-quality components can cause many hard-to-diagnose problems in an installation. 2) Dust caps are installed at IMC Networks to ensure factory-clean optical devices. These protective caps should not be removed until the moment of connecting the fiber cable to the device. Assure that the fiber is properly terminated, polished and free of any dust or dirt, and that the location is as free from dust and dirt as possible. 3) Store spare caps in a dust-free environment such as a sealed plastic bag or box so that when reinstalled they do not introduce any contamination to the optics. 4) Should it be necessary to disconnect the fiber device, reinstall the protective dust caps. 5) If you suspect that the optics have been contaminated, alternate between blasting with clean, dry, compressed air and flushing with methanol to remove particles of dirt. ELECTROSTATIC DISCHARGE PRECAUTIONS Electrostatic discharge (ESD) can cause damage to your add-in modules. Always observe the following precautions when installing or handling an add-in module or any board assembly. 1) Do not remove unit from its protective packaging until you’re ready to install it. 2) Wear an ESD wrist grounding strap before handling any module or component. If you do not have a wrist strap, maintain grounded contact with the system unit throughout any procedure requiring ESD protection. WARNING! Integrated circuits and fiber optic components are extremely susceptible to electrostatic discharge damage. Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices. 3) Hold boards by the edges only; do not touch the electronic components or gold connectors. 4) After removal, always place the boards on a grounded, static-free surface, ESD pad or in a proper ESD bag. Do not slide the board over any surface. WARRANTY During normal operation, link integrity pulses are transmitted by all point-to-point Ethernet devices. When an IMC Networks media converter receives valid link pulses, it knows that the device to which it is connected is up and sending pulses, and that the copper or fiber cable coming from that device is intact. The appropriate “LINK” LED is lit to indicate this. The IMC Networks media converter also sends out link pulses from its IMC Networks warrants to the original end-user purchaser that this product, EXCLUSIVE OF SOFTWARE, shall be free from defects in materials and workmanship under normal and proper use in accordance with IMC Networks' instructions and directions for a period of six (6) years after the original date of purchase. This warranty is subject to the limitations set forth below. At its option, IMC Networks will repair or replace at no charge the product which proves to be defective within such warranty period. This limited warranty shall not apply if the IMC Networks product has been damaged by unreasonable use, accident, negligence, service or modification by anyone other than an authorized IMC Networks Service Technician or by any other causes unrelated to defective materials or workmanship. Any replaced or repaired products or parts carry a ninety (90) day warranty or the remainder of the initial warranty period, whichever is longer. To receive in-warranty service, the defective product must be received at IMC Networks no later than the end of the warranty period. The product must be accompanied by proof of purchase, satisfactory to IMC Networks, denoting product serial number and purchase date, a written description of the defect and a Return Merchandise Authorization (RMA) number issued by IMC Networks. No products will be accepted by IMC Networks which do not have an RMA number. For an RMA number, contact IMC Networks at PHONE: (800) 624-1070 (in the U.S and Canada) or (949) 465-3000 or FAX: (949) 465-3020. The enduser shall return the defective product to IMC Networks, freight, customs and handling charges prepaid. End-user agrees to accept all liability for loss of or damages to the returned product during shipment. IMC Networks shall repair or replace the returned product, at its option, and return the repaired or new product to the end-user, freight prepaid, via method to be determined by IMC Networks. IMC Networks shall not be liable for any costs of procurement of substitute goods, loss of profits, or any incidental, consequential, and/or special damages of any kind resulting from a breach of any applicable express or implied warranty, breach of any obligation arising from breach of warranty, or otherwise with respect to the manufacture and sale of any IMC Networks product, whether or not IMC Networks has been advised of the possibility of such loss or damage. EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE, IMC NETWORKS MAKES NO OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, WITH RESPECT TO THIS IMC NETWORKS PRODUCT, INCLUDING WITHOUT LIMITATION ANY SOFTWARE ASSOCIATED OR INCLUDED. IMC NETWORKS SHALL DISREGARD AND NOT BE BOUND BY ANY REPRESENTATIONS OR WARRANTIES MADE BY ANY 2 7 Installing modules without understanding the effects of LinkLoss and FiberAlert can cause perfectly functioning units to appear flawed or even dead. If you are unfamiliar with LinkLoss and FiberAlert, IMC Networks strongly encourages you to read the following information. Contact IMC Networks technical support at (800) 624-1070 (U.S. and Canada), +32-16-550880 (Europe) or [email protected] for more information/assistance. ABOUT LINK INTEGRITY OTHER PERSON, INCLUDING EMPLOYEES, DISTRIBUTORS, RESELLERS OR DEALERS OF IMC NETWORKS, WHICH ARE INCONSISTENT WITH THE WARRANTY SET FORTH ABOVE. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED TO THE DURATION OF THE EXPRESS WARRANTY STATED ABOVE. Every reasonable effort has been made to ensure that IMC Networks product manuals and promotional materials accurately describe IMC Networks product specifications and capabilities at the time of publication. However, because of ongoing improvements and updating of IMC Networks products, IMC Networks cannot guarantee the accuracy of printed materials after the date of publication and disclaims liability for changes, errors or omissions. FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class A computing device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own expense. Any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. The use of non-shielded I/O cables may not guarantee compliance with FCC RFI limits. This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada. Installation Guide McBasic TX/FX Q U I C K S T A R T Introduction About McBasic TX/FX Installation McBasic TX/FX™ is a low-cost, IEEE 802.3 sin- Configuration gle-conversion media converter that converts Crossover/Pass-Through between 100Base-TX twisted pair and LinkLoss & FiberAlert 100Base-FX multi-mode or single-mode fiber. Auto-Negotiation It is available with one RJ-45 connector for the twisted pair port and several types of fiber con- LED Indicators Tech Support nectors, including ST, SC, MT and LC, for the Warranty/Safety Certifications fiber port. McBasic TX/FX is a 1U high, stand alone unit that includes diagnostic LEDs for each port and a universal (100/240 VAC) power supply. SAFETY CERTIFICATIONS UL: CE: Listed to UL1950 and CSA 22.2, No. 950, Safety of Information Technology Equipment, Including Electrical Business Equipment. The products described herein comply with the Council Directive on Electromagnetic Compatibility (89/336/EEC) and the Council Directive on Electrical Equipment Designed for use within Certain Voltage Limits (73/23/EEC). Certified to EN 60950, Safety of Information Technology Equipment, Including Electrical Business Equipment. For further details, contact IMC Networks. Installing McBasic TX/FX Questions or Comments about this manual? Contact [email protected]. Configuring McBasic TX/FX Before installation, configure McBasic TX/FX for the following features: • TX LinkLoss • FX LinkLoss 19772 Pauling • Foothill Ranch, CA 92610-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetworks.com Once installed, configure McBasic TX/FX for the following features: • FiberAlert • Auto-Negotiation © 2001-2003 IMC Networks. All rights reserved. The information in this document is subject to change without notice. IMC Networks assumes no responsibility for any errors that may appear in this document. McBasic is a trademark of IMC Networks. Other brands or product names may be trademarks and are the property of their respective companies. Document Number 55-80126-03 A1 McBasic TX/FX comes ready to install (with the exception of configuring certain features, if desired – see below). To install McBasic TX/FX, first make sure that the unit is placed on a suitable flat surface. Attach the cables between the McBasic TX/FX and each device that will be interconnected, then plug the unit into a reliable, filtered power source. NOTE: The default for all featuers is Disabled. April 2003 8 1 1 1 1 4 2 5 6 6 7 ">
/
Скачать
Просто дружеское напоминание. Вы можете просмотреть документ прямо здесь. Но самое главное, наш ИИ уже прочитал его. Он может объяснить сложные вещи простыми словами, ответить на ваши вопросы на любом языке и помочь вам быстро перемещаться даже по самым длинным или сложным документам.
Реклама