HP ProLiant DL180 Generation 6


Add to my manuals
58 Pages

advertisement

HP ProLiant DL180 Generation 6 | Manualzz

QuickSpecs

Overview

HP ProLiant DL180 Generation 6

Front View:

1.

Access panel

2.

Front LED Indicators

3.

Power on/off

4.

Optional DVD-RW or DVD-ROM drive

5.

Front USB Ports (2)

6.

Non-Hot Plug Non Redundant fans (4 fans)

7.

Air Baffle

8.

PCI Cage

9.

System Board

Rear View:

1.

Redundant Power Supply Bay (Optional)

2.

Power Supply Cable Socket

3.

Low Profile Card Slot

4.

PCI Expansion Card Slot

5.

PCI Expansion Card Slot

6.

UID LED Button

7.

(Optional) LO100i 10/100 Mbps LAN port for IPMI management (RJ-45)

8.

LAN Port

9.

LAN Port

10.

2 Rear USB 2.0 Ports

11.

VGA Port

12.

Serial Port

What's New

Announcing support for the Intel® Xeon® processor 5600 series-the next generation of intelligent server processors offering significant performance (up to 40% over single-core processors), power regulation (Low Voltage DIMMs) enhancements

Announcing the new High Efficiency server mode.

Support for 750 W and 460 W Platinum Power Supply

Support for I/O Accelerators

At A Glance

The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellence and 2U density for a variety of rack deployments and applications.

Processors:

Supports up to two Intel® Xeon® Six and Four -Core 5600 sequence processors with up to 12 MB Level 3 cache

Supports up to two Quad-Core Intel® Xeon® processors: 5500 sequence with 8MB Level 3 cache

Intel® 5520 Chipset

Memory:

Up to 12 DIMM slots

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 1

QuickSpecs

HP ProLiant DL180 Generation 6

Overview

Up to 192GB, using 16GB Quad-Rank PC3-8500R-7 DDR3 Registered (RDIMM) memory, operating at 800MHz when fully populated at 2 DIMMs per Channel in 12 slots

Up to 96GB, using PC3-10600R DDR3Registered (RDIMM) memory, operating at 1066MHz when fully populated at 2 DIMMs per Channel in 12 slots.

Up to 48GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fully populated at 2 DIMMs per Channel in 12 slots

NOTE: Half DIMM slots are available when one processor is installed.

Internal Drive Support:

Support for up to twenty-five (25) SFF with a Smart Array controller.

Hot Plug Serial ATA (SATA) Models: Up to 12.5 TB (25 x 500GB Hot Plug 2.5"hard drives)

Hot Plug Serial Attached SCSI (SAS) Models: Up to 12.5 TB ( 25 x 500GB Hot Plug 2.5"hard drives)

Support for up to fourteen (14) LFF with a Smart Array controller:

Hot Plug Serial ATA (SATA) Models: Up to 28.0TB (14 x 2TB Hot Plug 3.5" hard drives)

Hot Plug Serial Attached SCSI (SAS) Models: SAS Model: Up to 28.0TB (14 x 2TB Hot Plug 3.5" hard drives)

NOTE: Four (4), eight (8) and twelve (12) hard drives models are supported standard via BTO. Eight (8) and twelve (12) hard drive model support requires the addition of a Smart Array or HBA controller. Hot

Plug and SAS functionality require the addition of a Smart Array or HBA controller.

Standard model drive bays:

Four (4) 3.5"Large Form Factor (LFF) hot-plug drive bays supporting up to 6Gb/s SAS or 3Gb/s SATA transfer rate.

NOTE: Embedded SATA controller support transfer rate up to 1.5Gb/s SATA. HP Smart Array P212 or

P410 controller is required to achieve 6Gb/s SAS or 3Gb/s SATA transfer rate

Eight (8) 3.5" Large Form Factor (LFF) hot-plug drive bays supporting up to 6Gb/s SAS or 3Gb/s SATA transfer rate.

Twelve (12) 3.5" Large Form Factor (LFF) hot-plug drive bays supporting up to 3Gb/s SAS or 3Gb/s SATA transfer rate.

Optional drive bays:

Twenty Five (25) 2.5" Small Form Factor (SFF) hot-plug drive bays supporting up to 6Gb/s SAS or 3Gb/s

SATA transfer rate.

Eight (8) 2.5" Small Form Factor (SFF) hot-plug drive bays supporting up to 6Gb/s SAS or 3Gb/s SATA transfer rate.

Rear Two (2) 3.5" Large Form Factor (LFF) hot-plug drive bays to use with 12LFF bays supporting up to

3Gb/s SAS or 3Gb/s SATA transfer rate.

NOTE: Full Height/ Full Length Riser Option is not available when the Rear 2LFF drive bays is selected for the system.

NOTE: All Hard drive bay options except 4LFF require HP Smart Array P410 or P212 controller.

NOTE: To achieve highest possible stated transfer rate please make sure the firmware on the drive bays

(backplanes) and HP Smart Array controller up to date. Latest firmware are available to download from HP support web site.

Network Controller:

HP NC362i Integrated Dual Port Gigabit Server Adapter

Storage Controllers:

4 HDD BTO Models: HP Embedded SATA RAID Controller RAID 0,1,10

NOTE: Embedded SATA controller support transfer rate up to 3Gb/s SATA

NOTE: To enable RAID on Embedded SATA, use the HP Smart Array B110i SATA Raid controller, To enable use of the B110i, enter the ROM based setup utility(RBSU). The option for enabling RAID can be found in the

Advanced section of the RBSU

NOTE: For Hot Plug SATA, upgrade to the Smart Array Hot Plug Advance Pack for B110i

8 HDD BTO Models: HP Smart Array P410 /256MB Controller (RAID 0/1/1+0/5/5+0 NOTE: Support speed up to

6Gb/s SAS or 3Gb/s SATA

NOTE: Available upgrades: 512MB with BBWC or FBWC, Battery kit upgrade (for the 256MB cache), and Smart

Array Advanced Pack (SAAP)

12 HDD BTO Models: HP Smart Array P212 /256MB Controller(RAID 0/1/1+0/5/5+0)

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 2

QuickSpecs

HP ProLiant DL180 Generation 6

Overview

NOTE: A minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade is required to enable RAID 6, 6+0 NOTE: Support speed up to 3Gb/s SAS or 3Gb/s SATA

25 HDD BTO Model: HP Smart Array P212/256MB Controller (RAID 0/1/1+0/5/5+0)

NOTE: Available upgrades: P410 with FBWC, 256MB with BBWC, 512MB with FBWC, Battery kit upgrade (for the 256MB cache), and Smart Array Advanced Pack (SAAP). NOTE: Support speed up to 6Gb/s SAS or 3Gb/s

SATA

NOTE: To achieve highest possible stated transfer rate please make sure the firmware on the drive bays

(backplanes) and HP Smart Array controller up to date. Latest firmware are available to download from HP support web site

Expansion Slots:

Up to Four (4) available PCI-Express Slots via the three (3) PCI-E Slot Riser

One available Low Profile x16 PCI-Express slot using a Low profile Riser

One 3PCI-E x8 Full Height Kit, providing 2x8 full length/full height slots as well as an additional x8(x4 electrically

) slot

Two Full Height/ Full Length Riser options:

Option 1: 2 PCIe2x8 and 1 PCIex8(4) full-length/full-height slots (Standard)

Option 2: 2 PCIe2x8 full-length/full-height PCI-Express slots (Optional)

Option 3: 2 PCI-X, full-length/full-height riser Slots(Optional)

Option 4: 1 PCIe2x16 full-length / full-height slot (Optional)

Option 5: 2 PCIe2x8 and 1 PCIex8(4) full-length/full-height slots (Optional)

NOTE: Full Height/ Full Length Riser Option are not available when the Rear DVD or rear 2LFF drive bay are selected for the system. The rear DVD kit includes the riser option

Redundancy:

Fully redundant non-hot plug fans (Optional)

Hot plug power supply with optional redundancy

Power Sources:

Dual Common Slot Bay for Right Sized, Hot plug and Redundant Power

HP 750W CS HE Gold Power Supply (Standard on some models)

HP 460W CS HE Gold Power Supply (Standard on some models)

HP 460 W CS Platinum Power Supply Kit (Standard on some models)

HP 750W CS Platinum Power Supply Kit

Infrastructure Management:

With G6, ProLiant 100-series server administrators are able to deploy and monitor their servers using methods similar to 300 series servers and above. Agents and the Easy Set-up CD are available that provide a user experiences consistent with 300 series and above.

With Easy Set-up CD, customers get SmartStart "like" deployment tools that reduce the time required for server setup and updates. Easy Set-up CDs and their ISO images are provided with each ProLiant G6

100-series server and are used to perform assisted installations for one or two servers. Users performing multi-server installations involving large numbers of servers may require the following deployment tools:

SmartStart Scripting Toolkit - Automated scalable deployment utility

Smart Components - a self-executable software consisting of driver and firmware

With agents and providers, ProLiant 100 series servers get environmental monitoring that is similar and consistent to that of ProLiant 300 series servers and above. This server now offers the HP Insight

Management Agents and HP Insight Management WBEM Providers, two well established sets of management and Internet standards technologies that provide capabilities which provide integration to HP

Systems Insight Manager (SIM).

HP Insight Control for Linux, a product option, delivers essential infrastructure management that can help save time and money by making it easy to deploy, migrate, monitor, control and optimize your IT infrastructure through a single, simple management console. Insight Control for Linux supports Linux-based central management servers.

Ports:

Five USB ports (two front, two rear , one optional internal)

NOTE: In order to utilize the internal USB port the USB cable (P/N: 536769-B21) must be connected to the internal USB header

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 3

QuickSpecs

HP ProLiant DL180 Generation 6

Overview

Optical Drive:

Support for one (optional): DVD-ROM, DVD/CD RW

NOTE: In the12LFF or 25SFF drives bay model Optical drives are required to be installed with rear option kit

(P/N 515826-B21)

Form Factor:

2U rack models

Operating Systems and Virtualization Software:

Supports Windows, RHEL, SLES, VMware, and Citrix XenServer (Retail)

Deployment/Serviceability:

HP ProLiant DL180 G6 models have fixed rails which provide support for racks with round mounting holes and tool-free support for racks with square mounting holes (including Compaq/HP 7000, 9000, 10000 and HP series), with an adjustment range of 26" - 36"

Tool-less access to all system components for easy in rack serviceability

Customer Self Repair (CSR): HP products are designed with many CSR parts to minimize repair time and allow for greater flexibility in performing defective parts replacement

Warranty:

This product is covered by a global limited warranty and supported by HP Services and a worldwide network of

HP Authorized Channel Partners. Hardware diagnostic support and parts replacement is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. Hard drives have either a one year or three year warranty; refer to the specific hard drive

QuickSpecs for details.

NOTE: Server Warranty includes 3-Years Next Business Day Parts replacement, 0-Years Labor, 0-Years Onsite support. Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 4

QuickSpecs

Standard Features

HP ProLiant DL180 Generation 6

NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information -

Factory Integrated Models" section.

Processor

One of the following depending on Model

Six-Core Processors

Intel® Xeon® Processor X5670 (2.93 GHz, 12MB L3 Cache, 95W, DDR3-1333, HT, Turbo

2/2/2/2/3/3) FIO

NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.

Intel® Xeon® Processor X5660 (2.80 GHz, 12MB L3 Cache, 95W, DDR3-1333, HT, Turbo

2/2/2/2/3/3) FIO

NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.

Intel® Xeon® Processor X5650 (2.66 GHz, 12MB L3 Cache, 95W, DDR3-1333, HT, Turbo

2/2/2/2/3/3) FIO

Intel® Xeon® Processor L5640 (2.26GHz, 12MB L3 Cache, 60W, DDR3-1333, HT, Turbo

2/2/3/3/4/4) FIO

NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.

Quad -Core Processors

Intel® Xeon® Processor E5640 (2.66 GHz, 12MB L3 Cache, 80W, DDR3-1066, HT, Turbo

1/1/2/2) FIO

NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.

Intel® Xeon® Processor E5630 (2.53 GHz, 12MB L3 Cache, 80W, DDR3-1066, HT, Turbo

1/1/2/2) FIO

NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.

Intel® Xeon® Processor E5620 (2.40 GHz, 12MB L3 Cache, 80W, DDR3-1066, HT, Turbo

1/1/2/2) FIO

Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO

Intel® Xeon® Processor L5630 (2.13 GHz, 12M L3 Cache, 40W, DDR3-1066, HT, Turbo 1/1/2/2/)

FIO

NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.

Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)

Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)

Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800)

Intel® Xeon® Processor L5630 (2.13 GHz, 12ML L3 Cache, 40W, DDR3-1066, HT, Turbo

1/1/2/2/) FIO

NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.

Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2)

Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)

Two -Core Processors

Intel® Xeon® Processor E5503 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) FIO

NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.

NOTE: HT indicates that the processor model supports Intel® Hyper-Threading Technology.

NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 5

QuickSpecs

Standard Features

HP ProLiant DL180 Generation 6

Boost Technology, with 4, 3, 2, and 1 cores active.

NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed.

NOTE: For the Intel 5000 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes

Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage.

Upgradeability

Chipset

Upgradeable to two processors

Intel® 5520 Chipset

NOTE: For more information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/ .

Cache Memory

Memory Protection

Advanced memory protection

Mirroring Mode

Lockstep Mode

Memory

12 MB Level 3 cache (L5630,E5620,X5650)

4 MB Level 3 cache (E5506)

Type

Standard (Entry Models)

Standard (Base Models)

DDR3 Registered (RDIMM) or Unbuffered (UDIMM)

4GB (1 x 4GB)

8GB (2 x 4GB)

16GB (4 x 4GB) Standard (Performance

Models)

Maximum (RDIMM) 192GB (12 x 16GB)

Maximum (UDIMM) 48GB (12 x 4GB)

NOTE: Depending on the memory configuration and processor model, the memory speed may run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration Tool at: www.hp.com/go/ddr3memory-configurator .

DDR3 memory options part number decoder

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 6

QuickSpecs

Standard Features

HP ProLiant DL180 Generation 6

Network Controller

HP NC362i Integrated Dual Port Gigabit Server Adapter

Expansion Slots

Storage Controller

Slot Number Bus Speed Bus Number

*

Device

Number

**

0

Hot Plug

(Y/N)

N

Notes

1 x16 PCI-

Express x8 PCI-Express

6 Low Profile

2

3

4

2

3 x8 PCI-Express x4 PCI-Express

PCI-X

PCI-X

***

***

5

4

3

Dynamic

Dynamic

0

0

0

1

2

N

N

N

N

N

Full Length

Full Height

Full Length

Full Height

Full Length

Full Height

Full Length

Full Height

Full Length

Full Height

NOTE: All slots can accept universal keyed PCI cards.

NOTE: Support is limited to PCI-X cards only.

* Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number.

** Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest

Device ID by bus (starting with the lowest bus).

*** PCI-X bus speed will be 100MHz in maximum and support two PCI-X/100MHz cards.

**** Slot 2 contains bus 4 and bus 5 because BIOS configures this x16 PCI-express.

NOTE: PCI-X support is limited to PCI-X cards only.

NOTE: Slot to two x8 PCI-express slot for production riser, this is valid only on Option1: 2

PCIe2x8 full-length/full-height PCI-Express slots (Optional) or Option 4: 2 PCIe2x8 and 1 PCIex8

(4) full-length/full-height slots (Optional).

4HDD Models

8HDD Models

12HDD Models

HP Smart Array B110i SATA RAID

NOTE: To enable RAID on Embedded SATA, use the HP Smart Array

B110i SATA RAID Controller, To enable use of the B110i, enter the

ROM based setup utility(RBSU). The option for enabling RAID can be found in the Advanced section of the RBSU.

NOTE: Embedded SATA controller support transfer rate up to 3Gb/s

NOTE: A diskette drive or virtual FDD using LO100 Advanced Pack is needed to install storage controller drivers during a Windows operating system installation from a CD.

HP Smart Array P410/256MB Controller (RAID 0/1/1+0/5/5+0)

NOTE: Support transfer rate up to 6Gb/s SAS or 3Gb/s SATA

HP Smart Array P212/256MB Controller (RAID 0/1/1+0/5/5+0)

NOTE: Available upgrades: P410 with FBWC, 256MB with BBWC,

512MB with FBWC, Battery kit upgrade (for the 256MB cache), and

Smart Array Advanced Pack (SAAP).

NOTE: Support transfer rate up to 3Gb/s SAS or 3Gb/s SATA

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 7

QuickSpecs

Standard Features

HP ProLiant DL180 Generation 6

25HDD Models HP Smart Array P410/256MB Controller (RAID 0/1/1+0/5/5+0)

NOTE: Available upgrades: P410, 512MB with FBWC, Battery kit upgrade (for the 256MB cache), and Smart Array Advanced Pack

(SAAP).

NOTE: Support transfer rate up to 6Gb/s SAS or 3Gb/s SATA

NOTE: A minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade (P/N: 516471-B21) is required to enable RAID 6, 6+0

NOTE: To achieve highest possible stated transfer rate please make sure the firmware on the drive bays (backplanes) and HP Smart Array controller up to date. Latest firmware is available to download from HP support web site.

Storage

Diskette Drives

Optical Drives

Drive Bays

Maximum Internal

Storage

Hot Plug 3.5" SATA

Hot Plug 3.5" SAS

Hot Plug 2.5" SATA

Hot Plug 2.5" SAS

28.0TB (14 x 2TB)

28.0TB (14 x 2TB)

12.5TB (25 x 500GB)

12.5TB (25 x 500GB)

Interfaces

Via USB only

Optional HP Slim SATA DVD-ROM Optical Drive

Optional HP Slim SATA DVD RW Optical Drive

NOTE: Support in 4, 8, and 12 drive models. Optical drives can only be installed in 12 drive model and 25SFF drive bay system with rear option kit (P/N 515826-B21).

Up to 14 Hot Plug SAS/SATA 3.5" drives

Up to 25 Hot Plug SAS/SATA 2.5" drives

NOTE: 4 Drive Models are Non-Hot Pluggable. Smart Array Controller must be added for Hot Plug drive capability. 4 Drive Models can be upgraded with the addition of a Smart Array Controller and a SAS/SATA

Multi-lane cable (496013-B21).

NOTE: The addition of a Smart Array Controller requires the addition of a SAS/SATA Multi-lane cable (P/N 496013-B21).

Graphics

Network RJ-45

(Ethernet)

Serial

Graphics

USB

1

1

2 10/100/1000 NIC ports (plus 1 dedicated for the HP ProLiant Lights

Out 100i Remote Management)

5 total ports: (2) front, (2) rear, (1) optional internal

NOTE: In order to connect a USB device internally, the internal USB

Cable G6 Kit must be used (P/N 536769-B21).

NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usbsupport.html

.

32MB* shared supporting all display resolutions up to 1600x1200 16bpp@75Hz

NOTE: 8MB is dedicated to video memory.

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 8

QuickSpecs

Standard Features

Form Factor

Rack (2U), (3.5 in/8.89 cm)

HP ProLiant DL180 Generation 6

Embedded

Manageability

HP Lights-Out 100

(LO100) Advanced

HP Lights-Out 100, simplifies server setup, control, and lights-out remote administration of ProLiant 100 Series servers and functions without additional software. It can be accessed from any location via

LAN or Internet and works hand-in-hand with HP Systems Insight

Manager (SIM), helping customers unlock the value of the ProLiant platform and deliver the highest possible quality of IT service to the business. Advanced Licenses are required for Virtual KVM and Virtual

Media feature activation.

Key features of LO100 are:

IPMI 2.0 & SMASH CLP support

ROM Setup Utility

Improvements to virtual media with the addition of USB 2.0 drives and protocol support for much faster transfer speeds and DVD-

ROM support plus simplified virtual media (floppy and CD with no

FTTP server requirements)

Enhanced browser interface and embedded KVM over IP provides

OS-independent remote graphical console

24x7 Technical Support and Update (TSU) 1 year support and license upgrades included in Advanced license

HP Insight Control management software

HP Insight Control for

Linux

NOTE: For more information, see: http://www.hp.com/go/lo100

HP Insight Control for Linux, as a product option, delivers essential infrastructure management that can help save time and money by making it easy to deploy, monitor, remote control, and optimize your IT infrastructure through a single, simple management console. The Insight

Control for Linux installs and license software modules that are integrated into HP System Insight Manager.

The HP Insight Control for Linux (IC-Linux) serves environments requiring a Linux-based management consoles. See www.hp.com/go/iclinux

Insight Control server deployment

HP Insight Control include one year of 24 x 7 HP Software Technical

Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/insight

HP Insight Control server deployment is a deployment solution for HP

ProLiant and Integrity servers hosted on a Windows CMS. It automates the process of deploying and provisioning server software, enabling companies to quickly and easily adapt to changing business demands.

Insight Control server deployment includes software optimizations for

HP servers, including the HP scripting toolkits, configuration jobs for leading industry-standard operating systems, sample unattended files, and HP server support packs that include software drivers, management agents, and important documentation. Deploying servers can be accomplished either through imaging or through scripting.

Insight Control server deployment is hosted on a Windows server and is intended for heterogeneous environments deploying Windows, Linux,

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 9

QuickSpecs

Standard Features

Core Server

Management

HP ProLiant DL180 Generation 6

VMware ESX and Microsoft Hyper-V systems.

Insight Control server deployment includes one year of 24 x 7 HP

Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/insight .

ProLiant 100 Series G6

Core Management

Software

HP provides management solutions that are designed to simplify a server's installation, configuration, and maintenance throughout the entire server lifecycle. This provides the customers with higher levels of operational efficiency and highly reliable systems.

While ProLiant 100 series G6 servers do not support the Insight

Foundation Suite for ProLiant, they support a key subset of this important suite software tools and utilities which are very suitable for this class of server: SIM, SMH, agents, providers, and a SmartStart 'like' deployment CD called Easy Set-up which greatly simplifies server setup. Additionally the DL100 and SL100 G6 models support the

SmartStart Scripting Toolkit (SSSTK), an automated scalable deployment utility.

HP Systems Insight

Manager

Insight Management

Agents

Information on core management supported on ProLiant 100 series G6 servers can be found at these URLS:

Core Management: www.hp.com/go/coremanagement

HP ProLiant 100 series Easy Set-up CDs: www.hp.com/servers/easysetup

HP Systems Insight Manager (HP SIM) provides a unified, secure and extensible standards-based environment to centrally manage servers, storage and other infrastructure devices, (both HP and non-HP) across multiple operating system platforms.

HP Insight Management Agents and Insight Management

Providers are available for HP Systems Insight Manager (SIM)

Integration.

ProLiant 100-series G6 servers can use the same SNMP based

Insight Management Agents supported by other ProLiant servers.

As a result, administrators can use HP Systems Insight Manager

(SIM) 5.3 and greater to manage ProLiant 100-series G6 servers.

Administrators can also use any other SNMP- based management tool. These agents are obtained as part of the ProLiant 100-series model-specific "Easy Set-up" CDs, or through: www.hp.com/servers/easysetup

The following capabilities are enabled on the 100-series G6 servers by the SNMP agents:

Health monitoring capabilities, including monitoring for drives, fans, network, power supplies, and temperature

Alerting capabilities, including basic alert notification for Smart

Array drive pre-failure only

Performance monitoring capabilities providing information on

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 10

QuickSpecs

Standard Features

HP ProLiant DL180 Generation 6

Easy Set-up CD

SmartStart Scripting

Toolkit (SSSTK)

processor, memory, disk free space, network utilization

NOTE: For additional information, please see: http://www.hp.com/go/insight

Easy Set-up CDs are available on all 100-series G6 servers and are also available as an ISO image web download. HP ProLiant Easy Setup CDs provide easy, step-by-step, single and multi-server server utilities for the ProLiant 100-series G6 servers to streamline server setup for 100-series G6 servers. The user experience is consistent with

SmartStart and offers the following capabilities:

Boot environment and GUI

Assisted Installation: Windows 2003 Server and Windows 2008

Server drivers

Manual installation: Windows 2003 Server, Windows 2008 Server, and Linux drivers (specific OS support varies by server. Refer to each server's QuickSpecs for supported versions)

HP Insight Diagnostics

AutoRun

Array Configuration Utility (ACU) has been combined with Array

Diagnostics Utility (ADU) to offer both configuration of array controllers and storage devices and testing of array controller hardware

SmartStart Scripting Toolkit (SSSTK) and Smart Components for software and drivers for DL100 and SL100 servers

NOTE: OS and SW available for Manual Installation are listed on each servers' QuickSpecs.

The SmartStart Scripting Toolkit is a server deployment product that delivers an unattended automated installation for high-volume server deployments. The SmartStart Scripting Toolkit includes a set of utilities for configuring and deploying servers in a customized, predictable, and unattended manner. These utilities enable you to duplicate the configuration of a source server on target servers with minimum user interaction.

The Toolkit is designed for IT experts with experience in scripting operating system installations and configuring ProLiant server hardware.

NOTE: For additional information, please see: http://h18004.www1.hp.com/products/servers/management/toolkit/ index.html

Subscriber's Choice

Subscriber's Choice Driver and Support Alerts/Notifications is a webbased email subscription service that provides software and driver change notifications for ProLiant products. Sign up at: http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis.

ROMPaq, software and latest drivers

The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options; downloaded from Software and

Drivers download pages website at: http://www.hp.com/go/support and from www.hp.com/servers/easysetup . Contains the following:

HP Insight Management Agents for Systems Insight Manager

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 11

QuickSpecs

Standard Features

HP ProLiant DL180 Generation 6

(SIM) Integration

HP Systems Management Homepage

Array Configuration Utility (ACU)

Array Diagnostics Utility (ADU)

HP Insight Diagnostics

Industry Standard

Compliance

Security

ACPI V2.0 Compliant

PCI 2.2 Compliant

PXE Support

WOL Support

Microsoft® Logo certifications

IPMI 2.0 Compliant

Power-on password

Setup password

Diskette boot control

Secure Sockets Layer (SSL)

Secure Shell (SSH)

Security - Trusted

Platform Module

The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to authenticate the server platform. These artifacts can include passwords, certificates and encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a

Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user data and to ensure that a server running Windows Server 2008 has not been tampered with while the system was offline.

NOTE: For more information about TPM, including a white paper, go to www.hp.com/go/TPM

NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment.

NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing the key could result in data loss.

Server Power Cords

One 6' Highline (IEC-IEC) power cord ships standard

NOTE: HP ProLiant DL servers no longer ship standard with NEMA power cords (P/N 163719-

002) that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected to PDU's in data center racks so they now ship standard with a PDU power cord (416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle

(NEMA-15), the NEMA power cord (P/N 227099-001) must be ordered separately.

If customers require a local power cord, they can check the power cord matrix for the appropriate cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix

NOTE: Rack models ship standard with an IEC cable.

Localized cables included with geographic specific models in other world regions.

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 12

QuickSpecs

HP ProLiant DL180 Generation 6

Standard Features

UPS and PDU Power

Cord Matrix

Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page.

Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords .

Power Supply

HP has a new design for ProLiant power. The new Common Slot Power Supply bay. This design provides the customer with commonality in power supplies across multiple platforms to save on the cost of spares and allows HP to offer multiple power solutions to fit the customers' needs.

Many HP ProLiant Servers come with Common Slot, High Efficiency and Right-Size Power

Supplies. Common Slot (CS) designates commonality of the power supply across multiple

ProLiant servers. HP's new Common Slot power supplies are designed for highest efficiency to provide power efficiency without degrading performance of the ProLiant. Power Supplies will have efficiency ratings up to 92%. There are three Right Size power options available, depending on the configuration of your server. To make sure you select the correct power supply to meet your configuration, we suggest that you use the HP Power Advisor to decide the "Right-Size" for your configuration. All HP Common Slot power sources are UL, CE Mark Compliant, Hot Plug and

Redundant.

Common Slot ProLiant It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power

supply for your needs. HP offers Power Supply Options:

460Watts, Common Slot, 92% Efficiency

750Watts, Common Slot, 92% Efficiency

460Watts, Common Slot, 94% Efficiency

750Watts, Common Slot, 94% Efficiency

HP's ProLiant Common Slot Power supplies (460W & 750W) meet multiple Energy Efficiency

Initiatives. Climate Savers Computing Initiative GOLD, ECOS Consulting 80PLUS GOLD and plans on offering models that meet the Energy Star for Server requirements when they are published.

HP's ProLiant Common Slot Power supplies (1200W) meet multiple Energy Efficiency Initiatives.

Climate Savers Computing Initiative Bronze, ECOS Consulting 80PLUS Bronze Power Supply requirements.

Redundant Power: Optional (1+ 1 or n+n redundant) power supplies can be purchased through power supply option kits.

System Fans

4 system fans ship standard; Non-hot plug, Non-redundant

NOTE: Redundant fan kit (P/N 516009-B21) available for purchase.

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 13

QuickSpecs

HP ProLiant DL180 Generation 6

Standard Features

Operating Systems and

Microsoft Windows Server

Virtualization Software

Support for ProLiant

Servers

Microsoft Windows Server Hyper-V

Red Hat Enterprise Linux (RHEL)

SUSE Linux Enterprise Server (SLES)

VMware ESX Server

Citrix Essentials for XenServer (Retail)

NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and

Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/supportos and our driver download page http://www.hp.com/support/DL180G6

Rack Airflow

Requirements

Rack 10000 G2 series Cabinets

The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.

CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:

Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow

830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).

Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm).

CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack.

This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.

Rack Kit

HP ProLiant DL180 rack models have fixed rails which provide support for racks with round mounting holes and tool-free support for racks with square mounting holes (including Compaq/HP

7000, 9000, 10000 and HP series), with an adjustment range of 26" - 36".

Telco Rack Support

Support for all 2 and 4 post Telco racks and threaded hole racks requires an additional option kit from Rack Solutions. The Rack Solutions brackets can be purchased at: www.hp.com/go/rackandpower .

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 14

QuickSpecs

HP ProLiant DL180 Generation 6

Standard Features

Factory Express

Portfolio for Servers and Storage

HP Factory Express offers configuration, customization, integration and deployment services for

HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed.

Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP

BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches.

For more information on Factory Express services for your specific server model please contact your sales representative or go to: http://www.hp.com/go/factory-express .

HP Enterprise

Configurator

HPC Interconnect

The HP eConfigure Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact

HP's Customer Business Center or an Authorized Partner for assistance.

http://www.hp.com/products/configurator .

NOTE: High Performance Computing (HPC) interconnect technologies are available for this server under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC

Clusters with InfiniBand or Gigabit Ethernet: http://www.hp.com/techservers/clusters/ucp/index.html

InfiniBand

PCI-Express Generation 2 adapters

Service and Support

HP services provide total care and support expertise with committed response designed to meet your IT and business needs.

HP Care Pack services include coverage for the HP branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to 3kVA; these items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack.

To fully capitalize on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime.

Recommended Service - Simplify ProLiant solution implementation, maintenance and

management.

Support Service - 3-Year 24x7 4 hr Response service support coverage

Deployment Service - Hardware Installation

Enhanced Service - Optimize service level to increase IT performance and availability

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 15

QuickSpecs

Standard Features

HP ProLiant DL180 Generation 6

Support Service - 3-Year 24x7 24 hr Call to repair service support coverage

Support- - 3-Year 24x7 6 hr Call to repair service support coverage

Support Plus - 24x7 4 hr Response service support including OS coverage

Installation of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or

Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays.

For a complete listing of service offerings and information visit: http://www.hp.com/services/proliantservices http://h20219.www2.hp.com/services/us/en/warranty/carepack-servers-proliant.html

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 16

QuickSpecs

Models

HP ProLiant DL180 Generation 6

Four Drive Serial ATA (SATA) Models

NOTE: Upgrading from 4 Non-Hot Plug SATA hard drives to 4 Hot Plug SATA/SAS hard drives requires the addition of a storage controller and one Internal mini-SAS cable (P/N 496013-B21).

NOTE: Upgrading to 8 Hot Plug SATA/SAS hard drives requires the addition of a HP 2U G6 8HDD LFF DL18X KIT (P/N

506924-B21), storage controller (Smart Array P410/256MB recommended), and two Internal SATA/SAS cables (mini-SAS cable (P/N 496013-B21).

HP DL180G6 E5504

2x2GB 4LFF

487502-xx1

Processor

Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W,

DDR3-800)

Cache Memory

Memory

4MB shared L3 cache (E5504)

4GB (2 x 2GB) PC3-10600E (UDIMM)

Network Controller

Storage Controller

Hard Drive

Internal Storage

Optical Drive

Power Supply

Form Factor

HP NC362i Integrated Dual Port Gigabit Server Adapter

Embedded SATA Raid Standard RAID 0,1,10

1x 160GB Hot Plug SATA

NOTE: Hot-plug functionality requires the addition of a Smart Array controller.

8.0TB (4 x 2TB Hot Plug 3.5" SATA hard drives), Maximum

8.0TB (4 x 2TB Hot Plug 3.5" SAS hard drives), Maximum

None ship standard

460W common slot, high efficiency power supply

Rack (2U)

HP DL180G6 L5520

2x2GB 4LFF

487506-xx1

Processor

Cache Memory

Memory

Network Controller

Storage Controller

Hard Drive

Internal Storage

Optical Drive

Power Supply

Form Factor

Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W,

DDR3-1066, HT, Turbo 1/1/2/2)

8MB shared L3 cache (L5520)

4GB (2 x 2GB) PC3-10600E (UDIMM)

HP NC362i Integrated Dual Port Gigabit Server Adapter

Embedded SATA Raid Standard RAID 0,1,10

1x 160GB Hot Plug SATA

NOTE: Hot-plug functionality requires the addition of a Smart Array controller.

8.0TB (4 x 2TB Hot Plug 3.5" SATA hard drives), Maximum

8.0TB (4 x 2TB Hot Plug 3.5" SAS hard drives), Maximum

None ship standard

460W common slot, high efficiency power supply

Rack (2U)

HP DL180G6 E5506

1x4GB 4LFF

590637-xx1

Processor

Cache Memory

Memory

Network Controller

Storage Controller

Hard Drive

Internal Storage

Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W,

DDR3-800)

4MB shared L3 cache (E5506)

4GB (1 x 4GB) PC3-10600R-9 (RDIMM)

HP NC362i Integrated Dual Port Gigabit Server Adapter

HP Smart Array B110i SATA RAID Controller

None Ship Standard

8.0TB (4 x 2TB Hot Plug 3.5" SATA hard drives), Maximum

8.0TB (4 x 2TB Hot Plug 3.5" SAS hard drives), Maximum

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 17

QuickSpecs

Models

Optical Drive

Power Supply

Form Factor

HP ProLiant DL180 Generation 6

None ship standard

460W common slot, high efficiency power supply

Rack (2U)

Eight Drive Serial ATA (SATA) Models

NOTE: Supports up to 8 Hot Plug SATA or SAS Hard Drives.

Processor HP DL180G6 E5620

2x4GB 8LFF

590638-xx1

Cache Memory

Memory

Network Controller

Storage Controller

Hard Drive

Internal Storage

Optical Drive

Power Supply

Form Factor

Intel® Xeon® Processor E5620 (2.4 GHz, 12MB L3 Cache, 80W,

DDR3-1066, HT, Turbo 1/1/2/2)

8MB shared L3 cache

8GB (2 x 4GB) PC3-10600R-9 (RDIMM)

HP NC362i Integrated Dual Port Gigabit Server Adapter

HP Smart Array P410/256MB BBWC Controller (RAID 0/1/1+0/5/5+0)

NOTE: Smart Array Advanced Pack License Key upgrade (P/N 516471-

B21) is required to enable RAID 6, 6+0

None ship standard

16.0TB (8 x 2TB Hot Plug 3.5" SATA hard drives), Maximum

16.0TB (8 x 2TB Hot Plug 3.5" SAS hard drives), Maximum

None ship standard

460W common slot, high efficiency power supply

Rack (2U)

HP DL180G6 E5520

3x2GB 8LFF

487503-xx1

Processor

Cache Memory

Memory

Network Controller

Storage Controller

Hard Drive

Internal Storage

Optical Drive

Power Supply

Form Factor

Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W,

DDR3-1066, HT, Turbo 1/1/2/2)

8MB shared L3 cache

6GB (3 x 2GB) PC3-10600E (UDIMM)

HP NC362i Integrated Dual Port Gigabit Server Adapter

HP Smart Array P410 /256MB Controller (RAID 0/1/1+0/5/5+0)

NOTE: A minimum of 256 MB cache, battery kit, and Smart Array

Advanced Pack License Key upgrade (P/N 516471-B21) is required to enable RAID 6, 6+0

None ship standard

16.0TB (8 x 2TB Hot Plug 3.5" SATA hard drives), Maximum

16.0TB (8 x 2TB Hot Plug 3.5" SAS hard drives), Maximum

None ship standard

460W common slot, high efficiency power supply

Rack (2U)

HP DL180G6 L5630 1x4

GB 8LFF

590636-xx1

Processor

Cache Memory

Memory

Network Controller

Intel® Xeon® Processor L5630 (2.13 GHz, 12M L3 Cache, 40W, DDR3-

1066, HT, Turbo 1/1/2/2)

12MB shared L3 cache

4GB (1 x 4GB) PC3L-10600R-9 (RDIMM)

HP NC362i Integrated Dual Port Gigabit Server Adapter

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 18

QuickSpecs

Models

Storage Controller

Hard Drive

Internal Storage

Optical Drive

Power Supply

Form Factor

HP ProLiant DL180 Generation 6

HP Smart Array P410 /256MB Controller (RAID 0/1/1+0/5/5+0)

NOTE: A minimum of 256 MB cache, battery kit, and Smart Array

Advanced Pack License Key upgrade (P/N 516471-B21) is required to enable RAID 6, 6+0

None ship standard

16.0TB (8 x 2TB Hot Plug 3.5" SATA hard drives), Maximum

16.0TB (8 x 2TB Hot Plug 3.5" SAS hard drives), Maximum

None ship standard

460W common slot, high efficiency Platinum power supply

Rack (2U)

Twelve Drive Serial ATA (SATA) Models

NOTE: Internal Storage expandable to 14 SAS/SATA drives with 2 Rear Drive Option Kit (P/N 488234-B21)

HP DL180G6 E5620

2x4GB 12LFF US

590639-xx1

Processor

Intel® Xeon® Processor E5620 (2.4 GHz, 12MB L3 Cache, 80W,

DDR3-1066, HT, Turbo 1/1/2/2)

Cache Memory

Memory

12MB shared L3 cache

8GB (2 x 4GB) PC3-10600R-9 (RDIMM)

Network Controller

Storage Controller

Hard Drive

Internal Storage

Optical Drive

Power Supply

Form Factor

HP NC362i Integrated Dual Port Gigabit Server Adapter

HP Smart Array P212 /256MB BBWC Controller (RAID 0/1/1+0/5/5+0)

NOTE: Smart Array Advanced Pack License Key upgrade (P/N 516471-

B21) is required to enable RAID 6, 6+0

None ship standard (up to 12 Hot Plug SATA or SAS drives supported)

24.0TB (12 x 2TB Hot Plug 3.5" SATA hard drives), Maximum

24.0TB (12 x 2TB Hot Plug 3.5" SAS hard drives), Maximum

NOTE: Internal Storage expandable to 14 SAS/SATA drives with 2 Rear

Drive Option Kit (P/N 488234-B21)

None ship standard

750W common slot, high efficiency power supply

Rack (2U)

HP DL180G6 E5540

6x2GB 12LFF US

487507-xx1

Processor

Cache Memory

Memory

Network Controller

Storage Controller

Hard Drive

Internal Storage

Optical Drive

Power Supply

(2) Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W,

DDR3-1066, HT, Turbo 1/1/2/2)

8MB shared L3 cache

12GB (6 x 2GB) PC3-10600R (RDIMM)

HP NC362i Integrated Dual Port Gigabit Server Adapter

HP Smart Array P212 /256MB Controller (RAID 0/1/1+0/5/5+0)

NOTE: The minimum of 256 MB cache, battery kit, and Smart Array

Advanced Pack License Key upgrade (P/N 516471-B21) is required to enable RAID 6, 6+0

None ship standard (up to 12 Hot Plug SATA or SAS drives supported)

24.0TB (12 x 2TB Hot Plug 3.5" SATA hard drives), Maximum

24.0TB (12 x 2TB Hot Plug 3.5" SAS hard drives), Maximum

NOTE: Internal Storage expandable to 14 SAS/SATA drives with 2 Rear

Drive Option Kit (P/N 488234-B21)

None ship standard

750W common slot, high efficiency power supply

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 19

QuickSpecs

Models

Form Factor

HP ProLiant DL180 Generation 6

Rack (2U)

HP DL180G6 E5520

3x2GB 12LFF

487508-xx1

Processor

Cache Memory

Memory

Network Controller

Storage Controller

Hard Drive

Internal Storage

Optical Drive

Power Supply

Form Factor

Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W,

DDR3-1066, HT, Turbo 1/1/2/2)

8MB shared L3 cache

6GB (3 x 2GB) PC3-10600E (UDIMM)

HP NC362i Integrated Dual Port Gigabit Server Adapter

HP Smart Array P212 /256MB Controller (RAID 0/1/1+0/5/5+0)

NOTE: The minimum of 256 MB cache, battery kit, and Smart Array

Advanced Pack License Key upgrade (P/N 516471-B21) is required to enable RAID 6, 6+0

None ship standard (up to 12 Hot Plug SATA or SAS drives supported)

24.0TB (12 x 2TB Hot Plug 3.5" SATA hard drives), Maximum

24.0TB (12 x 2TB Hot Plug 3.5" SAS hard drives), Maximum

NOTE: Internal Storage expandable to 14 SAS/SATA drives with 2 Rear

Drive Option Kit (P/N 488234-B21)

None ship standard

750W common slot, high efficiency power supply

Rack (2U)

Twenty Five Drive SAS Models

HP DL180G6 X5650

4x4GB 25SFF US

590640-xx1

Processor

Cache Memory

Memory

Network Controller

Storage Controller

Hard Drive

Internal Storage

Optical Drive

Power Supply

Form Factor

(2) Intel® Xeon® Processor X5650 (2.66 GHz, 12MB L3 Cache, 95W,

DDR3-1333, HT, Turbo 2/2/3/3)

12MB shared L3 cache

16GB (4 x 4GB) PC3-10600R-9 (RDIMM)

HP NC362i Integrated Dual Port Gigabit Server Adapter

HP Smart Array P410/256MB BBWC Controller (RAID 0/1/1+0/5/5+0)

NOTE: Smart Array Advanced Pack License Key upgrade (P/N 516471-

B21) is required to enable RAID 6, 6+0

None Ship Standard

12.5TB (25 x 500GB Hot Plug 2.5" SATA hard drives), Maximum

12.5TB (25 x 500GB Hot Plug 2.5" SAS hard drives), Maximum

None ship standard

750 W common slot ,power supply

Rack (2U)

Country Code Key

xx=00 xx=29 xx=37 xx=42 xx=AA

U.S.

Japan

APD

Europe

PRC

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 20

QuickSpecs

Configuration Information - Factory Integrated Models

HP ProLiant DL180 Generation 6

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO product offerings and requirements.

NOTE: HP does not allow factory integration of options into standard models listed above.

Configure-to-order servers must start with a CTO Chassis.

NOTE: FIO indicates that this option is a Factory Installable Option.

Step 1: Base Configuration (choose one of the following configurable models)

Hot Plug LFF Models

HP ProLiant DL180 G6 Hot Plug SAS/SATA Rack CTO Chassis 507168-B21

Factory Integrated Model ships with:

HP NC362i Integrated Dual Port Gigabit Server Adapter

Three available PCI-Express slots:

Slot 1: x16 low-profile/half-height slot

Optional Slots 2, 3, & 4: 2x8 full-height/full length, 1x4 full-height/full length

(Recommended)

NOTE: Optional PCI-X option kit includes: Slot 1 and 2: full-length/full-height

PCI-X 100. PCI-X slots are 64 bits; 133 MHz capable if only one PCI-X card is installed in the server.

NOTE: Optional FL/FH option kit includes: Slot 1: full length/full height slot.

One HP SATA Embedded Cable Kit

One Highline IEC Power Cord

4 Non-Hot Plug Fans

Rack (2U), (3.5 in/8.89 cm)

Tool-less Fixed Rails

Hot Plug SFF Models

HP ProLiant DL180 G6 Hot Plug SAS/SATA Rack CTO Chassis

Factory Integrated Model ships with:

HP NC362i Integrated Dual Port Gigabit Server Adapter

Three available PCI-Express slots:

Slot 1: x16 low-profile/half-height slot

Optional Slots 2, 3, & 4: 2x8 full-height/full length, 1x4 full-height/full length

(Recommended)

NOTE: Optional PCI-X option kit includes: Slot 1 and 2: full-length/full-height

PCI-X 100. PCI-X slots are 64 bits; 133 MHz capable if only one PCI-X card is installed in the server.

NOTE: Optional FL/FH option kit includes: Slot 1: full length/full height slot.

One HP SATA Embedded Cable Kit

One Highline IEC Power Cord

4 Non-Hot Plug Fans

Rack (2U), (3.5 in/8.89 cm)

594911-B21

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 21

QuickSpecs

HP ProLiant DL180 Generation 6

Configuration Information - Factory Integrated Models

Step 2: Choose Required Options (only one of the following from each list unless otherwise noted)

HP Processors

NOTE: If 2 processors are desired, select one xxxxxx-L21 and one xxxxxxB21.

Six-Core Processors

Intel® Xeon® Processor X5670 (2.93 GHz, 12MB L3 Cache, 95W, DDR3-1333,

HT, Turbo 2/2/2/2/3/3), FIO

Intel® Xeon® Processor X5660 (2.80 GHz, 12MB L3 Cache, 95W, DDR3-1333,

HT, Turbo 2/2/2/2/3/3), FIO

Intel® Xeon® Processor X5650 (2.66 GHz, 12MB L3 Cache, 95W, DDR3-1333,

HT, Turbo 2/2/2/2/3/3), FIO

Intel® Xeon® Processor L5640 (2.26GHz, 12MB L3 Cache , 60W, DDR3-1333,

HT, Turbo 2/2/3/3/4/4), FIO

Quad-Core Processors

Intel® Xeon® Processor E5640 (2.66 GHz, 12MB L3 Cache, 80W, DDR3-1066,

HT, Turbo 1/1/2/2), FIO

Intel® Xeon® Processor E5630 (2.53 GHz, 12MB L3 Cache, 80W, DDR3-1066,

HT, Turbo 1/1/2/2), FIO

Intel® Xeon® Processor E5620 (2.40 GHz, 12MB L3 Cache, 80W, DDR3-1066,

HT, Turbo 1/1/2/2), FIO

Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066,

HT, Turbo 1/1/2/2), FIO

Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066,

HT, Turbo 1/1/2/2), FIO

Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800),

FIO

Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800),

FIO

Intel® Xeon® Processor L5630 (2.13 GHz, 12MB L3 Cache, 40W, DDR3-1066,

HT, Turbo 1/1/2/2), FIO

Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066,

HT, Turbo 1/1/2/2), FIO

Dual-Core Processor

Intel® Xeon® Processor E5503 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800),

FIO

590619-L21

590617-L21

590615-L21

590607-L21

590613-L21

590611-L21

590609-L21

508343-L21

508342-L21

573909-L21

508341-L21

590605-L21

508344-L21

594118-L21

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 22

QuickSpecs

HP ProLiant DL180 Generation 6

Configuration Information - Factory Integrated Models

HP Memory Registered RDIMMs

HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9

Memory Kit

HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9

Memory Kit

HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low

Power Memory Kit

HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9

Memory Kit

HP 8GB (1x8GB) Dual Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7

Memory Kit

HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7

Memory Kit

Unregistered with ECC UDIMMs

HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9

Memory Kit

HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9

Memory Kit

HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9

Memory Kit

NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3

Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator .

NOTE: Kits described as LP include Low Power DIMMs. For more information on

ProLiant Energy Efficient Features, see: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/

NOTE: There is a maximum support limitation of 8 ranks per memory channel

(maximum of 2 quad rank DIMMs per channel)

500656-B21

500658-B21

500660-B21

593339-B21

516423-B21

500666-B21

500668-B21

500670-B21

500672-B21

HP Drive Cage Options HP 2U G6 4HDD CAGE Kit, FIO

HP 2U G6 8HDD CAGE Kit, FIO

HP 2U G6 12HDD CAGE Kit, FIO

HP 2U 8SFF HDD CAGE & BKPLN G6 FIO

HP 2U G6 25 SFF CAGE FIO Kit

NOTE: Selection of the 25 SFF drive cage requires an HP Smart Array P410 or

P812 controller.

HP 2U Rear 2-Bay LFF Hard Drive Kit

506926-B21

506927-B21

506928-B21

534958-B21

516011-B21

488234-B21

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 23

QuickSpecs

HP ProLiant DL180 Generation 6

Configuration Information - Factory Integrated Models

HP Power Supplies

NOTE: Many HP ProLiant Servers now offer new power options, including

Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at: www.hp.com/go/proliant-energy-efficient

HP 460W CS HE Power Supply Kit

HP 750W CS HE Power Supply Kit

HP 460W CS Platinum Power Supply Kit

HP 750W CS Platinum Power Supply Kit

CAUTION: Optional Power Supplies used for Redundancy "MUST" match the original supplied power supply. Upgrades for more power headroom, when replacing the original power supplies must match if purchased for redundancy.

Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. In ProLiant Servers that have more than one power slot (bay), same size power supplies are recommended. If non-matched power supplies are inserted you will get errors and operation will fail.

503296-B21

512327-B21

593188-B21

593831-B21

Step 3: Choose Additional Factory Integratable Options (only one from each list unless otherwise noted)

HP Storage Controller HP P410/ZM FIO Smart Array Controller

HP Smart Array P411/256 MB w/ Battery FIO

462860-B21

491193-B21

HP Smart Array P410/256 MB w/ Battery FIO

HP Smart Array P212/256 MB w/ Battery FIO

491195-B21

491191-B21

Step 4: Choose Additional Options for Factory Integration

NOTE: For additional options, please refer to the "Core Options" and "Additional Options" sections below.

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 24

QuickSpecs

Core Options

HP ProLiant DL180 Generation 6

NOTE: Some options may not be available for factory integration. Please contact an HP sales representative for additional information.

HP Unique Options

HP DL180G6 Redundant Fan Kit

HP DL180G6 Rear DVD Cage Kit

NOTE: The x16 low profile slot is not available when this option is configured.

516009-B21

515826-B21

516006-B21

536769-B21

HP Dedicated Management Port Kit

HP Internal USB Cable G6 Kit

NOTE: This option required to connect a USB device internally.

HP DL180 G6 3PCI-E x8, Full Height Kit

NOTE: This option provides two x8 full-length/full-height slots as well as an additional x8 (x4 electrically) slot. This allows the DL180G6 to have a maximum of four (4) slots.

HP PCI-X Full Riser DL180 G6 Kit

NOTE: This option kit replaces the three internal expansion slots listed in step 1 base configuration.

NOTE: Optional PCI-X option kit includes: Slot 1: full-length/full-height PCI-X

100; Slot 2: Full length/Full-height PCI-X 100. PCI-X slots are 64 bits; 133 MHz capable if only one PCI-X card is installed in the server.

577668-B21

488230-B21

HP 2U G6 8HDD LFF DL18X KIT

NOTE: Upgrading to 8 Hot Plug SATA/SAS hard drives requires the addition of a storage controller (Smart Array P410/256MB recommended), two Internal

ATA/SAS cables, (mini-SAS cable (496013-B21).

HP DL180G6 Rear 2LFF Kit

NOTE: Supports 12 hard drive server models only. Hard Drives not included.

NOTE: This option replaces the 2 Full Length, Full Height x8 PCIe slots.

HP KIT 2PCI-E x8, FH, DL180G6

NOTE: This option provides 2 Full Length, Full Height x8 PCIe slots.

HP KIT PCI-E x16, DL180G6

NOTE: This option replaces the 2 Full Length, Full Height x8 PCIe slots.

506924-B21

488234-B21

497145-B21

497143-B21

HP Processor Six-Core Processors

Intel® Xeon® Processor X5670 (2.93 GHz, 12MB L3 Cache, 95W, DDR3-1333,

HT, Turbo 2/2/2/2/3/3)

Intel® Xeon® Processor X5660 (2.80 GHz, 12MB L3 Cache, 95W, DDR3-1333,

HT, Turbo 2/2/2/2/3/3)

Intel® Xeon® Processor X5650 (2.66 GHz, 12MB L3 Cache, 95W, DDR3-1333,

HT, Turbo 2/2/2/2/3/3)

Intel® Xeon® Processor L5640 (2.26GHz, 12MB L3 Cache, 60W, DDR3-1333,

HT, Turbo 2/2/3/3/4/4)

Quad-Core Processors

Intel® Xeon® Processor E5640 (2.66 GHz, 12MB L3 Cache, 80W, DDR3-1066,

HT, Turbo 1/1/2/2)

Intel® Xeon® Processor E5630 (2.53 GHz, 12MB L3 Cache, 80W, DDR3-1066,

HT, Turbo 1/1/2/2)

Intel® Xeon® Processor E5620 (2.40 GHz, 12MB L3 Cache, 80W, DDR3-1066,

HT, Turbo 1/1/2/2)

590619-B21

590617-B21

590615-B21

590607-B21

590613-B21

590611-B21

590609-B21

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 25

QuickSpecs

Core Options

HP ProLiant DL180 Generation 6

Intel® Xeon® Processor L5630 (2.13 GHz, 12ML L3 Cache, 40W, DDR3-1066,

HT, Turbo 1/1/2/2/)

Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066,

HT, Turbo 1/1/2/2)

Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066,

HT, Turbo 1/1/2/2)

Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066,

HT, Turbo 1/1/2/2)

Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800)

Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)

Two-Core Processors

Intel® Xeon® Processor E5503 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)

NOTE: HT indicates that the processor model supports Intel® Hyper-Threading

Technology.

NOTE: Turbo indicates the maximum potential frequency increment when using

Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active.

NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed.

NOTE: For the Intel 5000 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High

Performance/Wattage; "E" denotes Enterprise Performance/Wattage

(Mainstream); and "L" denotes Lower Wattage.

590605-B21

508344-B21

508343-B21

508342-B21

573909-B21

508341-B21

594118-B21

HP Memory Registered RDIMMs

HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9

Memory Kit

HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9

Memory Kit

HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low

Power Memory Kit

HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9

Memory Kit

HP 8GB (1x8GB) Dual Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7

Memory Kit

HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7

Memory Kit

HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9

Low Power Memory Kit

HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9

Low Power Memory Kit

HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9

Memory Kit

Unregistered with ECC UDIMMs

HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9

Memory Kit

HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9

Memory Kit

500656-B21

500658-B21

500660-B21

593339-B21

516423-B21

500666-B21

604504-B21

604506-B21

500662-B21

500668-B21

500670-B21

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 26

QuickSpecs

Core Options

HP ProLiant DL180 Generation 6

HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9

Memory Kit

NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3

Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator

NOTE: Kits described as LP include Low Power DIMMs. For more information on

ProLiant Energy Efficient Features, see: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/

500672-B21

HP Optical Drives

HP Hard Drives

HP Slim SATA DVD-ROM Optical Drive

HP Slim SATA DVDRW Optical Drive

NOTE: Optical drives can be installed in front, on 4 & 8 bay hard drive models.

NOTE: Optical drives can be installed in 12 and 25 drive model with the addition of rear option kit (P/N 515826-B21).

481041-B21

481043-B21

NOTE: The components of a storage subsystem (e.g. the drive, the

HBA/controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.

NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.

SAS Hot Plug SFF (2.5-inch) Enterprise (ENT) Drives

HP 300GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty

Hard Drive

HP 146GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty

Hard Drive

HP 146GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty

Hard Drive

HP 72GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty

Hard Drive

SAS Hot Plug LFF (3.5-inch) Enterprise (ENT) Drives

NOTE: 3G Hard Drives will operate at up to 3.0 Gb/s in 4 drive models that use the embedded controller.

HP 600GB 6G SAS 15K rpm LFF (3.5-inch) Dual Port Enterprise 3yr Warranty

Hard Drive

HP 450GB 6G SAS 15K rpm LFF (3.5-inch) Dual Port Enterprise 3yr Warranty

Hard Drive

HP 300GB 6G SAS 15K rpm LFF (3.5-inch) Dual Port Enterprise 3yr Warranty

Hard Drive

NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.html

(Worldwide)

NOTE: If selecting more than 4 hard drives or if using SAS hard drives, a Smart

Array controller and two SAS/SATA cables (P/N 464830-B21) are required.

SAS Hot Plug SFF (2.5-inch) Midline (MDL) Drives

HP 500GB 6G SAS 7.2K rpm SFF (2.5-inch) Dual Port Midline 1yr Warranty

Hard Drive

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010

507127-B21

512547-B21

507125-B21

512545-B21

516828-B21

516816-B21

516814-B21

507610-B21

Page 27

QuickSpecs

Core Options

HP ProLiant DL180 Generation 6

SAS Hot Plug LFF (3.5-inch) Midline (MDL) Drives

NOTE: 3G Hard Drives will operate at up to 3.0 Gb/s in 4 drive models that use the embedded controller.

HP 2TB 6G SAS 7.2K rpm LFF (3.5-inch) Dual Port Midline 1yr Warranty Hard

Drive

HP 1TB 6G SAS 7.2K rpm LFF (3.5-inch) Dual Port Midline 1yr Warranty Hard

Drive

SATA Hot Plug SFF (2.5-inch) Midline (MDL) Drives

HP 500GB 3G SATA 7.2K rpm SFF (2.5-inch) Midline 1yr Warranty Hard Drive

HP 160GB 3G SATA 7.2K rpm SFF (2.5-inch) Midline 1yr Warranty Hard Drive

SATA Hot Plug LFF (3.5-inch) Midline (MDL) Drives

HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive

HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive

HP 500GB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive

SATA Hot Plug LFF (3.5-inch) Entry (ETY) Drives

HP 250GB 3G SATA 7.2K rpm LFF (3.5-inch) Entry 1yr Warranty Hard Drive

HP 160GB 3G SATA 7.2K rpm LFF (3.5-inch) Entry 1yr Warranty Hard Drive

NOTE: Please see the QuickSpecs for Technical Specifications and additional specifications: http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html

(Worldwide)

SATA Hot Plug Midline (MDL) Solid State Drives

HP 60GB 3G SATA SFF (2.5-inch) Midline 1yr Warranty Solid State Drive

HP 120GB 3G SATA SFF (2.5-inch) Midline 1yr Warranty Solid State Drive

SATA Hot Plug 3.5" Midline (MDL) Solid State Drives

HP 60GB 3G SATA LFF (3.5-inch) Midline 1yr Warranty Solid State Drive

HP 120GB 3G SATA LFF (3.5-inch) Midline 1yr Warranty Solid State Drive

NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13415_div/13415_div.html

(Worldwide)

507616-B21

507614-B21

507750-B21

530888-B21

507632-B21

454146-B21

458928-B21

571230-B21

458945-B21

572071-B21

572073-B21

570761-B21

570763-B21

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 28

QuickSpecs

Core Options

HP Networking

HP ProLiant DL180 Generation 6

Gigabit Ethernet Adapters

HP NC112T PCIe Gigabit Server Adapter

HP NC360T PCI Express Dual Port Gigabit Server Adapter

HP NC364T PCI Express Quad Port Gigabit Server Adapter

NOTE: Does not support Windows 2000.

HP NC365T 4-port Ethernet Server Adapter

HP NC373F PCI Express Multifunction Gigabit Server Adapter

HP NC373T PCI Express Multifunction Gigabit Server Adapter

HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter

10 Gigabit Ethernet Adapters

NOTE: No more than two10GbE I/O devices are supported in a single ProLiant server.

NOTE: A minimum of two Gigabytes (2 GB) of server memory is required per each adapter.

NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately.

HP NC522SFP Dual Port 10GbE Server Adapter

HP NC550SFP Dual Port 10GbE Server Adapter

NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs .

503746-B21

412648-B21

435508-B21

593722-B21

394793-B21

394791-B21

458492-B21

468332-B21

581201-B21

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 29

QuickSpecs

Additional Options

HP ProLiant DL180 Generation 6

HP Entry-Level Server

Management

HP LO100i Advanced Pack, No Media 1-Server License including 1 year of 24x7

Technical Support and Updates

NOTE: For additional License Kits please see the Lights-Out 100i QuickSpecs at: www.hp.com/go/lo100 .

530521-B21

HP Insight Software HP Insight Control for Linux

HP Insight Control for Linux, 1-server license, including one year of 24x7

Technical Support and Updates, Electronic

NOTE: This part number can be purchased as a single license or as multiple licenses with a single activation key. Customer will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service.

NOTE: Electronic software is available in all countries except China and Japan.

For China and Japan should order the physical equivalent.

HP Insight Control for Linux, No Media, 1-Server license, including one year of

24x7 Technical Support and Updates

HP Insight Control for Linux, Media pack (DVD) - No licenses included

NOTE: This optional Media pack DVD contains the ISO image for HP Insight

Control for Linux, HP Systems Insight Manager, HP Insight Control power management, HP Insight Control virtual machine management, and an integrated installer. Servers must be acquired separately.

NOTE: This Media pack is optional because the latest ISO image and latest updates may be downloaded at no cost from: http://www.hp.com/go/ic-linux (click on Download button).

NOTE: Licenses ship without media. The Media Kit for Insight Control for Linux can be ordered separately, or can be downloaded at: http://www.hp.com/go/iclinux (click on Download button).

NOTE: Electronic software is available in all countries except China and Japan.

For China and Japan should order the physical equivalent.

NOTE: Customer will receive a license entitlement certificate, which must be redeemed online or via fax in order to obtain the license activation key(s).

Includes one year of 24 x 7 HP Software Technical Support Service.

NOTE: For additional License Kits, including electronic licensing options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_div/13019_div.html

HP Insight Control server deployment

HP Insight Control server deployment Electronic License including 1 year 24x7

Technical Support and Updates

HP Insight Control server deployment 1-Server License including 1 year 24x7

Technical Support and Updates

NOTE: Licenses ship without media. The Insight Control Media Kit can be ordered separately, or can be downloaded at: http://www.hp.com/go/insightupdates .

NOTE: Electronic software is available in all countries except China and Japan.

For China and Japan should order the physical equivalent.

NOTE: Customer will receive a license entitlement certificate, which must be redeemed online or via fax in order to obtain the license activation key(s).

Includes one year of 24 x 7 HP Software Technical Support Service.

NOTE: For additional license kits please see the Insight Control QuickSpecs at:

TC213AAE

TC209A

TC208A

T9082AAE

452151-B21

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 30

QuickSpecs

Additional Options

HP ProLiant DL180 Generation 6

http://h18004.www1.hp.com/products/quickspecs/12631_div/12631_div.html

600278-B21

HP I/O Accelerator

Options

HP 160GB SLC PCIe ioDrive

NOTE: A low-profile PCI bracket is included for use in low-profile slots.

NOTE: A minimum of 4 GB of system memory is required per card

HP 320GB MLC PCIe ioDrive

NOTE: A low-profile PCI bracket is included for use in low-profile slots.

NOTE: A minimum of 8 GB of system memory is required per card

HP 320GB SLC PCIe ioDrive Duo

NOTE: A minimum of 8 GB of system memory is required per card

HP 640GB MLC PCIe ioDrive Duo

NOTE: A minimum of 16 GB of system memory is required per card

NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13587_div/13587_div.html

(Worldwide)

HP Graphics Options

HP Graphic Card Power Adapter Kit

NOTE: The kit is applicable for 4LFF,8LFF and 8SFF cages . The Graphic

Power Adapter Kit can support up to 150 Watts.

HP Security - TPM

HP Trusted Platform Module Option Kit

HP Storage Controllers SAS Controllers

HP Smart Array P212 Controller

HP P212/Zero Memory Smart Array Controller

HP P212/256MB Smart Array Controller

HP Smart Array P410 Controller

HP Smart Array P410/256MB Controller

HP Smart Array P410/512MB BBWC Controller

HP Smart Array P410/1G with FBWC

HP Smart Array P410/512MB with FBWC

HP Smart Array P411 Controller

HP Smart Array P411/256MB Controller

HP Smart Array P411/512MB BBWC

HP Smart Array P411/1G Flash Backed Write Cache

HP Smart Array P411/512MB Flash Backed Write Cache

Smart Array P800 Controller

HP Smart Array P800/512 BBWC Controller

HP Smart Array P812 Controller

HP Smart Array P812/1G Flash Backed Cache Controller

Optional Upgrades

HP Int SAS/SATA Multi-Lane Cable Kit

600279-B21

600281-B21

600282-B21

533955-B21

488069-B21

462828-B21

462834-B21

462862-B21

462864-B21

572532-B21

578230-B21

462830-B21

462832-B21

572531-B21

578229-B21

381513-B21

487204-B21

464830-B21

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 31

QuickSpecs

Additional Options

HP ProLiant DL180 Generation 6

HP Mini SAS to Mini SAS 28in Cable Assy

NOTE: Supports internal drives on the DL180 G6 with the Smart Array P800

Controller.

1G Flash Backed Write Cache

256 MB Cache Module

NOTE: Supported on HP Smart Array P212 Controller only.

512MB Flash Backed Write Cache

512MB BBWC

NOTE: Supported on HP Smart Array P410 Controller and HP Smart Array P411

Controller only.

Battery Kit upgrade

NOTE: To enable BBWC on the 256MB cache.

NOTE: Supported on HP Smart Array P212 Controller, HP Smart Array P410

Controller, and HP Smart Array P411 Controller only.

HP 8484 to Mini SAS 33in Cable Assembly

NOTE: Cable for use connecting the Smart Array P800 Controller to internal hard disk drives on select HP ProLiant G6 Servers.

HP Smart Array Hot Plug Advanced Pack for B110i No Media 1-Server license including 1yr 24x7 Technical Support

HP Smart Array Advanced Pack No Media 1-Server license including 1yr 24x7

Technical Support

NOTE: This part number can be used to purchase a single license or to order multiple licenses with a single activation key. Customers will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s).

Include one year of 24x7 HP Software Technical Support Services.

NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13203_div/13203_div.html

(Smart Array P212 Controller) http://h18000.www1.hp.com/products/quickspecs/13201_div/13201_div.html

(Smart Array P410 Controller) http://h18000.www1.hp.com/products/quickspecs/13202_div/13202_div.html

(Smart Array P411 Controller)

SAS HBA

HP SC08Ge Host Bus Adapter

NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13082_div/13082_div.html

(SC08Ge HBA)

HP SC08e 6Gb 2-ports Ext PCIe SAS HBA

NOTE: This is a 2 x4 External Port HBA.

NOTE: This is only approved for the HP Storage Works P2000 G3 SAS Modular

Smart Array.

NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13651_div/13651_div.html

SCSI HBA

HP SC11Xe Host Bus Adapter

NOTE: Recommended HBA for SCSI tape drive connect.

496013-B21

534562-B21

462968-B21

534916-B21

462967-B21

462969-B21

591734-B21

TC421A

516471-B21

488765-B21

614988-B21

412911-B21

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 32

QuickSpecs

Additional Options

HP ProLiant DL180 Generation 6

NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12566_div/12566_div.html

(SCSI HBA)

HP InfiniBand Options QLogic IB 4X QDR PCI-e G2 Dual-port HC

HP IB 4X QDR CX-2 PCI-e G2 Dual Port HCA

HP IB 4X DDR CX-2 PCI-e G2 Dual Port HCA

NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13078_div/13078_div.html

HP Backup & Recovery

Software

Data Protector Express

HP Data Protector Express 4.0 SP1 Backup Server

HP Data Protector Express 4.0 SP1 for Microsoft Small Business Server

HP Data Protector Express Backup Server 4.0 SP1 Upgrade from Data Protector

Express Single Server Edition

NOTE: Only one of these Data Protector Express base products is required. To see available options: http://www.hp.com/go/dataprotectorexpress

HP Tape Backup

NOTE: For the complete range of StorageWorks tape drives, autoloaders, libraries and media see: http://www.hp.com/go/tape . For hardware and software compatibility of HP StorageWorks tape backup products see: http://www.hp.com/go/connect .

HP StorageWorks DAT 160 SAS Internal Tape Drive

NOTE: For installation into 1U SAS Rack-Mount Kit (AE459B) or 3U SAS Rack-

Mount Kit (AG576B). No peripheral bay available for installation into the server.

Connection using the HP SC44Ge SAS Host Bus Adapter (416096-B21) recommended.

HP StorageWorks 1U USB Rack-Mount Kit with one DAT 320 USB Tape Drive

HP StorageWorks DAT 320 SAS Internal Tape Drive

NOTE: For installation into 1U SAS Rack-Mount Kit (AE459B) or 3U SAS Rack-

Mount Kit (AG576B). No peripheral bay available for installation into the server.

Connection using the HP SC44Ge SAS Host Bus Adapter (416096-B21) recommended.

HP StorageWorks LTO-2 Ultrium 448 SAS Internal Tape Drive

NOTE: For installation into 1U SAS Rack-Mount Kit (AE459B) or 3U SAS Rack-

Mount Kit (AG576B). No peripheral bay available for installation into the server.

Connection using the HP SC44Ge SAS Host Bus Adapter (416096-B21) recommended.

HP StorageWorks LTO-3 Ultrium 920 SAS Internal Tape Drive

NOTE: For installation into 1U SAS Rack-Mount Kit (AE459B) or 3U SAS Rack-

Mount Kit (AG576B). No peripheral bay available for installation into the server.

Connection using the HP SC44Ge SAS Host Bus Adapter (416096-B21) recommended.

HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Tape Autoloader

NOTE: Requires HP 1U Tape Autoloader Rack-Mount Kit (AH166A) for rack installation. Connection using the HP SC44Ge SAS Host Bus Adapter (416096-

B21) recommended.

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010

583211-B21

592520-B21

592521-B21

BB117BA

BB118BA

BB117BT

Q1587A

AP835A

AJ830A

DW085A

EH847A

AH558A

Page 33

QuickSpecs

Additional Options

HP ProLiant DL180 Generation 6

HP StorageWorks MSL2024 Tape Library with one LTO-3 Ultrium 920 SAS

Drive

NOTE: Connection using the HP SC44Ge SAS Host Bus Adapter (416096-B21) recommended.

AH559A

HP Disk Backup

NOTE: For the complete range of StorageWorks D2D Backup Systems see: http://www.hp.com/go/d2d . For the complete range of StorageWorks RDX drives and media see: http://www.hp.com/go/rdx . For hardware and software compatibility of HP StorageWorks disk backup products see: http://www.hp.com/go/connect .

HP StorageWorks D2D Backup Systems with Backup Data Deduplication

HP StorageWorks D2D2502i Backup System

NOTE: 1.5TB of usable network disk backup capacity. Network connected appliance with connectivity using the iSCSI protocol. If the server requires a hardware iSCSI initiator, the QLogic QLA4050 Host Bus Adapter is recommended.

HP StorageWorks D2D2504i Backup System

NOTE: 3.0TB of usable network disk backup capacity. Network connected appliance with connectivity using the iSCSI protocol. If the server requires a hardware iSCSI initiator, the QLogic QLA4050 Host Bus Adapter is recommended.

USB Removable Media RDX Disk Backup Systems

HP StorageWorks RDX320 Internal Removable Disk Backup System

NOTE: For installation into 1U USB Rack-Mount Kit (A8007A). No peripheral bay available for drive installation into the server. 320GB of disk capacity per data cartridge.

HP StorageWorks RDX500 Internal Removable Disk Backup System

NOTE: For installation into 1U USB Rack-Mount Kit (A8007A). No peripheral bay available for drive installation into the server. 500GB of disk capacity per data cartridge.

HP StorageWorks RDX750 Internal Removable Disk Backup System

NOTE: For installation into 1U USB Rack-Mount Kit (A8007A). No peripheral bay available for drive installation into the server. 750GB of disk capacity per data cartridge.

EJ001A

EJ002A

AJ767A

AJ934A

AW577A

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 34

QuickSpecs

HP ProLiant DL180 Generation 6

Additional Options

HP StorageWorks

Options

StorageWorks Fibre Channel HBA

NOTE: The following is a list of all Fibre Channel Host Bus Adapters for

Windows and Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html

.

Brocade Fibre Channel HBAs

HP 81B PCIe 8Gb FC Single Port HBA

HP 82B PCIe 8Gb FC Dual Port HBA

HP 41B PCIe 4Gb FC Single Port HBA

HP 42B PCIe 4Gb FC Dual Port HBA

Emulex Fibre Channel HBAs

HP StorageWorks 81E 8Gb SP PCI-e FC HBA

HP 82E 8Gb Dual-port PCI-e FC HBA

HP StorageWorks FC2142SR 4Gb PCI-e HBA

HP StorageWorks FC2242SR Dual Channel 4Gb PCI-e FC HBA

QLogic Fibre Channel HBAs

HP StorageWorks 81Q PCI-e FC HBA

HP 82Q 8Gb Dual Port PCI-e FC HBA

HP StorageWorks FC1142SR 4Gb PCI-e HBA

HP StorageWorks FC1242SR Dual Channel 4 Gb PCI-e HBA

StorageWorks SCSI HBA

HP U320e SCSI Host Bus Adapter

NOTE: Recommended for MSL SCSI Tape Library connect.

StorageWorks Converged Network Adapter

HP CN1000E 2P Converged Network Adapter

AP769A

AP770A

AP767A

AP768A

AJ762A

AJ763A

A8002A

A8003A

AK344A

AJ764A

AE311A

AE312A

AH627A

AW520A

HP Disk Storage

Systems

MSA SAN Storage Arrays

HP StorageWorks MSA60 Array

NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12627_div/12627_div.html

HP StorageWorks MSA70 Array

NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12652_div/12652_div.html

418408-B21

418800-B21

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 35

QuickSpecs

HP ProLiant DL180 Generation 6

Additional Options

HP Uninterruptible

Power Systems

HP Rack-mountable UPS

HP R1500 G2 UPS

HP R1.5 VA 1U UPS NA

HP R1.5 VA 1U UPS INTL

HP, R1.5kVA UPS, 1U, JPN/TW

HP R/T3000 UPS

HP R/T3000 UPS, High voltage, NA/JPN

HP R/T3000 UPS, High voltage, detachable inlet cord INTL

HP Rack-Mountable R5500 UPS

HP R5500 3U Intl UPS

HP R5500 3U NA/JP UPS

NOTE: For additional information on all HP Uninterruptible Power Systems and accessories please go to: www.hp.com/products/ups (Worldwide)

NOTE: For additional information on sizing your server, please reference: http://www.upssizer.com

AF419A

AF418A

AF421A

AF453A

AF454A

AF416A

AF426A

HP Power Distribution

Units

Monitored PDUs

HP Monitored Power Distribution Unit: Full Rack Version

HP 8.6 kVA S1324 Monitored PDU- single input, 3Ø, 24A (NA/JPN)

HP 8.3 S1140 Monitored PDU- single input, 1Ø, 40A (NA/JPN)

HP 11 kVA S1316 Monitored PDU- single input, 3Ø, 16A (INTL)

HP 7.3 kVA S1132 Monitored PDU- single input, 1Ø, 32A (INTL)

HP Monitored Power Distribution Unit: Half Rack Version

HP 4.9 kVA S124 Monitored PDU- single input, 1Ø, 24A (NA/JPN)

HP 7.3 kVA S132 Monitored PDU- single input, 1Ø, 32A (INTL)

Modular PDUs 1U/0U (Up to 28 outlets)

4.9 kVA Modular PDU, 24A, NA/JPN

8.3 kVA Modular PDU, 40A, NA/JPN

3.6 kVA Modular PDU, 16A, INTL

7.3 kVA Modular PDU, 32A, INTL

NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12118_div/12118_div.html

(Worldwide)

AF504A

AF506A

AF508A

AF510A

AF914A

AF915A

252663-D72

252663-D73

252663-B24

252663-B31

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 36

QuickSpecs

HP ProLiant DL180 Generation 6

Additional Options

HP Rack Series

HP Rack 10000 G2 Series (Carbon/Graphite Metallic)

HP Universal Rack 10642 G2 Pallet ALL

HP Universal Rack 10642 G2 Shock ALL

NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed.

NOTE: Please see the Rack 10000 G2 QuickSpecs for Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html

(Worldwide)

NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower .

AF001A

AF002A

HP Rack Options

HP USB and SD

Options

HP KVM Switch Options

HP 0x2x8 KVM Server Console G2 Switch

HP 0x2x16 KVM Server Console G2 Switch

NOTE: Cat5e cables are required to connect Interface Adapters to Console

Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm .

HP Serial Console Server Options

0x2x16 KVM Server Console G2 Switch with Virtual Media and CAC

0x2x32 KVM Server Console G2 Switch with Virtual Media and CAC

1x1Ex8 KVM IP Console Switch G2 with Virtual Media and CAC

2x1Ex16 KVM IP Console Switch G2 with Virtual Media and CAC

4x1Ex32 KVM IP Console Switch G2 with Virtual Media and CAC

NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console

Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm .

NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm .

Rack Kits

HP Rack Cable Management Velcro Clips

AF616A

AF617A

AF618A

AF619A

AF620A

AF621A

AF622A

379820-B21

HP External USB CD/DVD R/RW Optical Drive

HP USB-PS/2 Mouse

HP USB 04 Standard Keyboard

HP 2GB USB Flash Media Drive Key Kit

NOTE: HP qualified blank USB key for use with HP ProLiant servers that support the VMware virtualization environment and other HP value-add software like

SmartStart. HP recommends this industry standard USB flash device for use with VMware ESXi. USB device must be installed in the internal slot of the

ProLiant server for use with VMware ESXi. Refer to HP VMware Getting Started

Guide for installation instructions.

FS943AA#ABA

DC369A

DT528A#ABA

608447-B21

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 37

QuickSpecs

HP ProLiant DL180 Generation 6

Additional Options

HP Care Pack Services Hardware Services 4-Hour On-site Service

13-Hour x 5-Day Coverage, 3 Years, Electronic

24-Hour x 7-Day Coverage, 3 Years, Electronic

Hardware Services Next Business Day On-Site Service

9-Hour x 5-Day Coverage, 3 Years, Electronic

Hardware Services 6-Hour Call to Repair On-Site Service

6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,

Electronic

Hardware Installation, Electronic

NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack .

UH271E

UH272E

UH270E

UH273E

UH301E

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 38

QuickSpecs

Memory

HP ProLiant DL180 Generation 6

NOTE: Memory configurations listed do not apply to "Factory Integrated Models".

HP ProLiant DL180 G6

Standard Memory (depending on model)

4GB (1 x 4GB) PC3-10600R-9 Registered memory, with Advanced ECC Capabilities Memory installed.

8GB (2 x 4GB) PC3-10600R-9 Registered memory, with Advanced ECC Capabilities Memory installed.

16GB (4 x 4GB) PC3-10600R-9 Registered memory, with Advanced ECC Capabilities Memory installed.

Maximum Memory

Up to 192GB memory is available with the optional installation of PC3-8500R Registered DIMM memory kits.

NOTE: Charts do not represent all possible memory configurations.

DDR3 memory population guidelines

For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator

Some DIMM installation guidelines are summarized below:

For servers with twelve (12) memory slots

There are three (3) channels per processor; six (6) channels per server

There are two (2) DIMM slots for each memory channel; twelve (12) total slots

Memory channel 1 consists of the two (2) DIMMs that are closest to the processor

Memory channel 3 consists of the two (2) DIMMs that are furthest from the processor

DIMM slots that are white should be populated first

Do not mix Unbuffered memory (UDIMMs) with Registered memory (RDIMMs)

Do not install DIMMs if the corresponding processor is not installed

If only one processor is installed in a 2CPU system, only half of the DIMM slots are available

To maximize performance, balance the total memory capacity between all installed processors

It is not required, but it is recommended to load the channels similarly if possible

If any Quad rank DIMMs are installed, all channels are limited to only 2 DIMMs per channel.

You can only install two quad-rank DIMMs per channel

You can install two UDIMMs per channel; if available, the third slot in the channel must remain empty

Populate DIMMs from heaviest load (quad-rank) to lightest load (single-rank) within a channel

Heaviest load (DIMM with most ranks) within a channel goes furthest from the chipset

If mixing DIMM voltage is a requirement, please note that the DIMMs will run at 1.5V since all 1.35V are capable of supporting 1.5V operations

Low Voltage DIMMs can only be used with Intel Xeon 5600 series processors.

For memory mirroring mode, channel 3 must be unpopulated. Channels 1 and 2 are populated identically

For lock-step mode, channel 3 must be unpopulated. DIMMs in channels 1 and 2 will be installed in pairs. The paired slots will be 1,4; 2,5; 3;6 on a 3DPC system or 1,4; 2,5; on a 2DPC system

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 39

QuickSpecs

HP ProLiant DL180 Generation 6

Memory

DIMM Type ->

Registered DIMMS (RDIMMs)

DIMM Rank ->

DIMM Capacity ->

DIMM Native Speed

(MHz) ->

Voltage

12 slot servers

Single

Rank

(1R)

4GB

1333

LV/Reg

2GB

1333

Reg

Dual Rank (2R)

4GB

1333

Reg

8GB

1066

Reg

SLOTS THAT CAN BE POPULATED

12 12 12 12

8GB

1333

LV/Reg

12

Quad Rank (4R)

4GB

1066

Reg

12

16GB

1066

Reg

12

Unbuffered with ECC DIMMs

Single

Rank

(1R)

1GB

1333

Reg

12

(UDIMMs)

12 slot servers

MAXIMUM CAPACITY (GB)

48 24 48 96 96 48 192 12

POPULATED DIMM SPEED (MHz)

1 DIMM Per

Channel

2 DIMM Per

Channel

1333

1333 *

1333

1333 *

1333

1333 *

1066

1066

1333

1333 *

1066

800

1066

800

1333

1066

* Supported with BIOS update via ROM Based Setup Utility (RBSU). UDIMM support is on 12-slot server.

Dual Rank (2R)

2GB

1333

Reg

12

24

1333

1066

4GB

1333

Reg

12

48

1333

1066

NOTES:

PC3-10600 DIMMs have a maximum speed of 1333MHz. PC3-8500 DIMMs have a maximum speed of 1066MHz

Mixing DIMM speeds is allowed, but the system processor speed rules always override the DIMM capabilities.

If you do mix DIMM speeds, the memory bus will default to the minimum clock rate of all DIMMs in the system - even if the slower DIMM is on the other processor.

If you install 1x 1066MHz DIMM in channel 1 and 1x 1333MHz DIMM in channel 2, the maximum speed will be

1066MHz.

If you install 1x 1066MHz DIMM in channel 1 and 5x 1333MHz DIMMs with 1 DIMM Per Channel (DPC) in each of the other channels, the maximum speed will be 1066MHz.

If you install 3DPC in one channel (if applicable) and 1DPC in all other channels, you run at 800MHz.

Maximum memory speed will also depend on the processor installed.

References to the above MHz speeds are for the various speeds of DDR3 DIMMs; 1333 refers to DDR3-1333, etc.

DIMM slot and configuration diagrams

Basic memory slot & population diagram

Population order; start with "A" first, "B" second, "C" third, etc.

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 40

QuickSpecs

HP ProLiant DL180 Generation 6

Memory

Chnl 1

Chnl 2

Chnl 3 5

3

4 slot #

1

2

6

CPU1

12 DIMM SLOTS (6 per CPU node)

CPU2

population order

D

A slot #

1

2 population order

D Chnl 1

A

Chnl 2

F

E

B

C

5

3

4

6

F

E

B

C

Chnl 3

Standard memory configuration (1 CPU model)

Chnl 1

Chnl 2

Chnl 3

6GB, consisting of three (3) 2GB dual-rank PC3-10600 RDIMMs

5

3

4 slot #

1

2

6

CPU1

population order

D: empty

A: 2GB DIMM

E: empty

B: 2GB DIMM

F: empty

C: 2GB DIMM

5

3

4 slot #

1

2

6

Standard memory plus optional memory (1 CPU model)

CPU2

E: empty

B: empty

F: empty

C: empty population order

D: empty Chnl 1

A: empty

Chnl 2

Chnl 3

Chnl 1

Chnl 2

Chnl 3

30GB, consisting of three (3) 2GB RDIMMs plus three (3) 8GB RDIMMs

3x 2GB dual-rank PC3-10600 RDIMMs

3x 8GB dual-rank PC3-8500 RDIMMs

5

3

4 slot #

1

2

6

CPU1

population order

D: 8GB DIMM

A: 2GB DIMM

E: 8GB DIMM

B: 2GB DIMM

F: 8GB DIMM

C: 2GB DIMM

5

3

4 slot #

1

2

6

Standard memory replaced with optional memory (1 CPU model)

RDIMM maximum configuration

CPU2

population order

D: empty Chnl 1

A: empty

Chnl 2 E: empty

B: empty

F: empty Chnl 3

C: empty

96GB, consisting of six (6) 16GB quad-rank PC3-8500 RDIMMs

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 41

QuickSpecs

Memory

Chnl 1

Chnl 2

Chnl 3 5

6

4 slot #

3

1

2

CPU1

population order

D: 16GB DIMM

A: 16GB DIMM

E: 16GB DIMM

B: 16GB DIMM

I: 16GB DIMM

C: 16GB DIMM

UDIMM maximum configuration (1 CPU model)

Chnl 1

Chnl 2

Chnl 3

24GB, consisting of six (6) 4GB dual-rank PC3-10600 UDIMMs

5

6

4 slot #

3

1

2

CPU1

population order

D: 4GB DIMM

A: 4GB DIMM

E: 4GB DIMM

B: 4GB DIMM

F: 4GB DIMM

C: 4GB DIMM

5

6

4 slot #

3

1

2

Standard memory replaced with optional memory (2 CPU model)

RDIMM maximum configuration

Chnl 1

Chnl 2

Chnl 3

192GB, consisting of twelve (12) 16GB quad-rank PC3-8500 RDIMMs

5

6

4 slot #

3

1

2

CPU1

population order

D: 16GB DIMM

A: 16GB DIMM

E: 16GB DIMM

B: 16GB DIMM

F: 16GB DIMM

C: 16GB DIMM

5

6

4 slot #

3

1

2

UDIMM maximum configuration (2 CPU model)

48GB, consisting of twelve (12) 4GB dual-rank PC3-10600 UDIMMs

5

6

4 slot #

3

1

2

HP ProLiant DL180 Generation 6

CPU2

population order

Chnl 1 D: empty

A: empty

E: empty Chnl 2

B: empty

I: empty

C: empty

Chnl 3

CPU2

population order

Chnl 1 D: empty

A: empty

E: empty Chnl 2

B: empty

F: empty

C: empty

Chnl 3

CPU2

population order

D: 16GB DIMM Chnl 1

A: 16GB DIMM

E: 16GB DIMM Chnl 2

B: 16GB DIMM

F: 16GB DIMM Chnl 3

C: 16GB DIMM

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 42

QuickSpecs

HP ProLiant DL180 Generation 6

Memory

Chnl 1

Chnl 2

Chnl 3 5

6

4 slot #

3

1

2

CPU1

population order

D: 4GB DIMM

A: 4GB DIMM

E: 4GB DIMM

B: 4GB DIMM

F: 4GB DIMM

C: 4GB DIMM

5

6

4 slot #

3

1

2

NOTE: Capacity references are rounded to the common Gigabyte values.

1GB = 1024MB

2GB = 2048MB

4GB = 4096MB

8GB = 8192MB

16GB = 16384MB

CPU2

population order

D: 4GB DIMM Chnl 1

A: 4GB DIMM

E: 4GB DIMM Chnl 2

B: 4GB DIMM

F: 4GB DIMM Chnl 3

C: 4GB DIMM

For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator

HP Memory Registered RDIMMs

HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9

Memory Kit

HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9

Memory Kit

HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9

Memory Kit

HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low

Power Memory Kit

HP 8GB (1x8GB) Dual Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7

Memory Kit

HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7

Memory Kit

HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9

Low Power Memory Kit

HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9

Low Power Memory Kit

HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9

Memory Kit

Unregistered with ECC UDIMMs

HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9

Memory Kit

HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9

Memory Kit

HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9

Memory Kit

500656-B21

500658-B21

593339-B21

500660-B21

516423-B21

500666-B21

604504-B21

604506-B21

500662-B21

500668-B21

500670-B21

500672-B21

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 43

QuickSpecs

Memory

HP ProLiant DL180 Generation 6

NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3

Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator .

NOTE: Kits described as LP include Low Power DIMMs. For more information on

ProLiant Energy Efficient Features, see: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 44

QuickSpecs

Storage

8 Drive Cage with DVD-Drive bay

12 Drive Cage

HP ProLiant DL180 Generation 6

1-8 Eight 3.5" Hot Plug SAS/SATA Hard Drive Bays

9 DVD-ROM, DVD RW

1-12 Twelve 3.5" Hot Plug SAS/SATA Hard Drive Bays

13-14

Not

Shown

Two Rear 3.5" Hot Plus SAS/SATA Hard Drive Bays

Drive Support

Removable Media

DVD-ROM

DVD RW

Quantity

Supported

Up to 1

Up to 1

Position

Supported Controller

9 Integrated IDE (ATAPI) (optional)

9 Integrated IDE (ATAPI) (optional)

Hard Drives

NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.

NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.

SATA Hot Plug SFF (2.5-inch) Midline (MDL) Drives

500GB 3G SATA 7.2K

160GB 3G SATA 7.2K

Quantity

Supported

Up to 8 with 8 drive cage

Up to 25 with 25 drive cage

Position

Supported

1-8

1-25

Controller

HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

NOTE: Smart Array P212 Controllers recommended.

HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 45

QuickSpecs

HP ProLiant DL180 Generation 6

Storage

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

HP Smart Array Hot Plug Advance Pack for B110i

SATA Hot Plug LFF (3.5-inch) Midline (MDL) Drives

2TB 3G SATA 7.2K

1TB 3G SATA 7.2K

500GB 3G SATA 7.2K

Quantity

Supported

Up to 8 with 8 drive cage

Position

Supported Controller

1-8 HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

Up to 14 with 12 drive cage +

Rear Drive Cage

1-14 NOTE: Smart Array P212 Controllers recommended.

HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

HP Smart Array Hot Plug Advance Pack for B110i

SATA Hot Plug LFF (3.5-inch) Entry (ETY) Drives

250GB 3G SATA 7.2K

160GB 3G SATA 7.2K

Quantity

Supported

Up to 8 with 8 drive cage

Position

Supported Controller

1-8 HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

Up to 14 with 12 drive cage +

Rear Drive Cage

1-14 HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

HP Smart Array Hot Plug Advance Pack for B110i

SATA Hot Plug Midline (MDL) Solid State Drives

60GB 3.0G SATA SSD

120GB 3.0G SATA SSD

Quantity

Supported

Up to 8 with 8 drive cage

Position

Supported Controller

1-8 HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 46

QuickSpecs

HP ProLiant DL180 Generation 6

Storage

Up to 25 with 25 drive cage

1-25

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array Hot Plug Advance Pack for B110i

SATA Hot Plug 3.5" Midline (MDL) Solid State Drives

Quantity

Supported

Position

Supported Controller

60GB 3.0G SATA SSD

120GB 3.0G SATA SSD

Up to 8 with 8 drive cage

1-8 HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array B110i Hot Plug Advance Pack for B110i

SAS Hot Plug SFF (2.5-inch) Midline (MDL) Drives

500GB 6G SAS 7.2K

Quantity

Supported

Up to 8 with 8 drive cage

Position

Supported Controller

1-8 HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

Up to 25 with 25 drive cage

1-25 HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

SAS Hot Plug LFF (3.5-inch) Midline (MDL) Drives

2TB 6G SAS 72K

1TB 6G SAS 7.2K

Quantity

Supported

Up to 8 with 8 drive cage

Position

Supported Controller

1-8 HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 47

QuickSpecs

HP ProLiant DL180 Generation 6

Storage

Up to 14 with 12 drive cage +

Rear Drive Cage

1-14

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

SAS Hot Plug SFF (2.5-inch) Enterprise (ENT) Drives

Quantity

Supported

Position

Supported Controller

300GB 6G 10K SAS

146GB 6G 15K SAS

146GB 6G 10K SAS

72GB 6G 15K SAS

Up to 8 with 8 drive cage

Up to 25 with 25 drive cage

1-8

1-25

HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

SAS Hot Plug LFF (3.5-inch) Enterprise (ENT) Drives

Quantity

Supported

Position

Supported Controller

600GB 6G SAS 15K DP

450GB 6G SAS 15K DP

300GB 6G SAS 15K

Up to 8 with 8 drive cage

Up to 14 with 12 drive cage +

Rear Drive Cage

1-8

1-14

HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P410/256 MB Controller

HP Smart Array P410/512 MB BBWC Controller

HP Smart Array P410/512 MB FBWC Controller

HP Smart Array P410/1G FBWC Controller

HP Smart Array P812/1G FBWC Controller

HP Smart Array P800/512 BBWC Controller

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 48

QuickSpecs

Storage

External Storage

Quantity

Supported

Up to 4 60 Modular Smart Array

70 Modular Smart Array

Up to 8

Up to 2

Up to 4

HP ProLiant DL180 Generation 6

Position

Supported Controller

External HP Smart Array P212/Zero Memory Controller

HP Smart Array P212/256 MB Controller

HP Smart Array P800/512 BBWC Controller

External

External

HP Smart Array P411/256 MB Controller

HP Smart Array P411/512 FBWC Controller

HP Smart Array P411/512 MB FBWC Controller

HP Smart Array P411/1G FBWC Controller

HP Smart Array P812/1G Flash Backed Cache Controller

HP Smart Array P800/512 BBWC Controller

HP Smart Array P212 Zero Memory Controller

HP Smart Array P212/256 MB Controller

External HP Smart Array P411/256 MB Controller

HP Smart Array P411/512 MB FBWC Controller

HP Smart Array P411/512 MB FBWC Controller

HP Smart Array P411/1G FBWC Controller

HP Smart Array P812/1G Flash Backed Cache Controller

HP Smart Array P800/512 BBWC Controller

Tape and Disk Backup

NOTE: For the complete range of StorageWorks tape drives, autoloaders, libraries and media, including the internal fitting models, see: http://www.hp.com/go/tape . For the complete range of StorageWorks D2D Backup Systems see: http://www.hp.com/go/d2d . For the complete range of StorageWorks RDX drives and media see: http://www.hp.com/go/rdx .

For hardware and software compatibility of HP StorageWorks disk and tape backup products see: http://www.hp.com/go/connect .

Position

External

Recommended Controller

HP SC11Xe Host Bus Adapter

Part Number

412911-B21

HP StorageWorks SCSI

Tape Drives, External

LTO-1 Ultrium 232

LTO-2 Ultrium 448

LTO-3 Ultrium 920

LTO-3 Ultrium 960

LTO4 Ultrium 1760

LTO-4 Ultrium 1840

DAT 40

DAT 72

DAT 160

1U Rack-Mount Kit

3U Rack-Mount Kit

HP StorageWorks USB

Tape Drives, External

DAT 40

DAT 72

DAT 160

DAT 320

1U USB Rack-Mount Kit

External

Please check the full compatibility information at: http://www.hp.com/go/connect

USB 2.0 Port N/A

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 49

QuickSpecs

Storage

HP StorageWorks SAS

Tape Drives, External

DAT 160

DAT 320

LTO-2 Ultrium 448

LTO-3 Ultrium 920

LTO-4 Ultrium 1760

LTO-4 Ultrium 1840

LTO-5 Ultrium 3000

LTO-5 Ultrium 3280

1U Rack-Mount Kit

3U Rack-Mount Kit

HP StorageWorks SCSI

Tape Autoloaders,

External

DAT 72x10 Autoloader

1/8 G2 Autoloader

HP StorageWorks SCSI

Tape Libraries,

External

MSL2024

MSL4048

MSL8096

MSL6000

HP StorageWorks SAS

Tape Autoloaders and

Libraries, External

1/8 G2 Autoloader

MSL2024

MSL4048

MSL8096

HP StorageWorks Fibre

Channel Tape

Libraries, External

MSL2024

MSL4048

MSL8096

MSL6000

HP StorageWorks USB

RDX Removable Disk

Backup System,

External

RDX160

RDX320

RDX500

RDX750

External

External

External

External

External

External

HP Smart Array P212 SAS controller

Please check the full compatibility information at: http://www.hp.com/go/connect

HP SC11Xe Host Bus Adapter

Please check the full compatibility information at: http://www.hp.com/go/connect

HP U320e SCSI Dual Channel Controller

Please check the full compatibility information at: http://www.hp.com/go/connect

HP Smart Array P212 SAS controller

Please check the full compatibility information at: http://www.hp.com/go/connect

Please consult the EBS connectivity matrix at: http://www.hp.com/go/ebs for connectivity information and the supported Fibre Channel HBAs shown in this QuickSpecs.

USB 2.0 port

HP ProLiant DL180 Generation 6

462828-B21

412911-B21

AH627A

462828-B21

N/A

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 50

QuickSpecs

HP ProLiant DL180 Generation 6

Storage

HP StorageWorks D2D

Backup Systems, iSCSI

D2D2500i

D2D4000i

HP StorageWorks D2D

Backup Systems, Fibre

Channel

D2D4000fc

Rack Mount Embedded Network Controller. If the server requires a hardware iSCSI initiator, the QLogic QLA4050 Host Bus

Adapter is recommended.

Rack Mount Direct server attach is not supported, requires connection via

SAN fabric. See: http://www.hp.com/go/connect

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 51

QuickSpecs

Power Specifications

HP 460W Power Supply

Part Number - AC 460W PSU

503296-B21

Input Voltage Range (Vrms)

100 to 240

Frequency Range (Nominal)

(Hz)

50/60

Nominal Input Voltage (Vrms)

Maximum Rated Output Wattage

100

460

Nominal Input Current (A rms)

Max Rated Input Wattage Rating

(Watts)

Max. Rated VA (Volt-Amp)

Efficiency (%) at Max. Rated

Output Wattage

5.5

526

548

87.5

Power Factor

Leakage Current (mA)

Max. Inrush Current (A peak)

Max. Inrush Current duration

(mS)

Maximum British Thermal Unit

Rating (BTU-Hr)

0.97

0.42

30

20

1794

HP 750W Power Supply

Part Number - AC 750W PSU

512327-B21

Input Voltage Range (Vrms)

100 to 240

Frequency Range (Nominal)

(Hz)

Nominal Input Voltage (Vrms)

Maximum Rated Output Wattage

Nominal Input Current (A rms)

50/60

100

750

8.9

857 Max Rated Input Wattage Rating

(Watts)

Max. Rated VA (Volt-Amp)

Efficiency (%) at Max. Rated

Output Wattage

Power Factor

894

87.5

0.97

Leakage Current (mA)

Max. Inrush Current (A peak)

Max. Inrush Current duration

(mS)

Maximum British Thermal Unit

Rating (BTU-Hr)

0.42

30

20

2925

0.97

0.50

30

20

2892

120

750

7.4

847

884

88.5

0.97

0.50

30

20

1773

120

460

4.5

520

542

88.5

HP ProLiant DL180 Generation 6

0.97

0.83

30

20

1725

208

460

2.6

505

527

91

0.97

0.87

30

20

1725

200

460

2.5

505

527

91

0.97

0.92

30

20

1715

220

460

2.4

503

524

91.5

0.97

0.96

30

20

1715

230

460

2.3

503

524

91.5

0.97

1.00

30

20

1715

240

460

2.2

503

524

91.5

0.97

0.83

30

20

2812

208

750

4.3

824

859

91

0.97

0.87

30

20

2812

200

750

4.1

825

859

91

0.97

0.92

30

20

2797

220

750

3.9

820

854

91.5

0.97

0.96

30

20

2797

230

750

3.7

820

854

91.5

0.97

1.00

30

20

2797

240

750

3.6

820

854

91.5

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 52

QuickSpecs

Power Specifications

HP 460W Platinum Power

Supply Part Number - AC

460W PSU

593188-B21

Input Voltage Range (Vrms)

100 to 240

Frequency Range (Nominal)

(Hz)

50/60

Nominal Input Voltage (Vrms)

Maximum Rated Output Wattage

Nominal Input Current (A rms)

Max Rated Input Wattage Rating

(Watts)

100

460

5.3

512

526

89.8

Max. Rated VA (Volt-Amp)

Efficiency (%) at Max. Rated

Output Wattage

Power Factor

Leakage Current (mA)

Max. Inrush Current (A peak)

Max. Inrush Current duration

(mS)

Maximum British Thermal Unit

Rating (BTU-Hr)

0.42

1747

HP 750W Platinum Power

Supply

Part Number - AC 460W PSU

593831-B21

Input Voltage Range (Vrms)

100 to 240

Frequency Range (Nominal)

(Hz)

Nominal Input Voltage (Vrms)

Maximum Rated Output Wattage

Nominal Input Current (A rms)

50/60

100

750

8.6

841 Max Rated Input Wattage Rating

(Watts)

Max. Rated VA (Volt-Amp) 863

89.2

Efficiency (%) at Max. Rated

Output Wattage

Power Factor

0.42

Leakage Current (mA)

Max. Inrush Current (A peak)

Max. Inrush Current duration

(mS)

Maximum British Thermal Unit

Rating (BTU-Hr)

2868

0.50

1722

0.50

2825

120

750

7.1

828

850

90.6

120

460

4.3

505

518

91.2

HP ProLiant DL180 Generation 6

208

460

2.5

493

506

93.2

0.83

1683

0.985

0.87

30

20

1682

200

460

2.4

493

506

93.3

0.92

1679

220

460

2.3

492

505

93.5

1678

230

460

2.2

492

505

93.6

0.96

1677

240

460

2.1

491

504

93.6

1.00

208

750

4.2

809

830

92.7

0.83

2761

0.985

0.87

30

20

2757

200

750

4.0

808

829

92.8

0.92

2753

220

750

3.8

807

828

93.0

2749

230

750

3.6

806

827

93.1

0.96

2747

240

750

3.4

805

826

93.2

1.00

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 53

QuickSpecs

Power Specifications

Optional Country Power Cords and Jumper Cords

WW HP 2m 15A C20 C13 Universal Jumper Cord

Brazil HP 1.83m 10A C13 NBR14136 Power Cord

HP ProLiant DL180 Generation 6

AF590A

AF591A

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 54

QuickSpecs

Technical Specifications

System Unit

HP ProLiant DL180 Generation 6

Dimensions (H x W x D)

3.45" x 17.64" x 28.23" in (8.76 x 44.80 x 71.71 cm)

(with bezel)

Weight

(approximate)

Maximum

(all hard drives, power supplies, and processors installed)

Minimum

(one hard drive, power supply, and processor installed)

45.0 lb (16.80 kg)

32.0 lb (11.94 kg)

Input Requirements

(per power supply)

BTU Rating

Rated Line Voltage

90 -- 132 VAC,

180 - 264 V

Rated Input Current

460 Watt

750 Watt

7.1 A (at 120 VAC)

3.5 A (at 240 VAC)

7.4 A (at 120 VAC)

3.6 A (at 240 VAC)

Rated Input Frequency 50 to 60 Hz

Rated Input Power

Maximum

460 & 750 watt - 852 W

460 Watt 1773 BTU/hr (at 120

VAC)

1715 BTU/hr (at 240

VAC)

750 Watts 2892 BTU/hr (at 120

VAC)

2797 BTU/hr (at 240

VAC

Power Specifications

To review typical system power ratings use the Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliantenergy-efficient

Power Supply Output

(per power supply)

System Inlet

Temperature

Click on the system of interest. Example: DL180 G6

Follow the instructions of the next screens.

Rated Steady-State

Power

460 W (at 100 VAC)

750 W (at 100 VAC)

460 W (at 200 VAC)

750 W (at 200 VAC)

Maximum Peak Power 460 W (at 100 VAC)

750 W (at 100 VAC)

460 W (at 200 VAC)

750 W (at 200 VAC)

Operating

10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m

(1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed.

System performance may be reduced if operating with a fan fault or above 30°C

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 55

QuickSpecs

Technical Specifications

HP ProLiant DL180 Generation 6

Relative Humidity

(non-condensing)

Altitude

Acoustic Noise

Non-operating

Operating

Non-operating

(86°F).

-30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr).

10 to 90% relative humidity (Rh), 28°C

(82.4°F) maximum wet bulb temperature, noncondensing.

5 to 95% relative humidity (Rh), 38.7°C

(101.7°F) maximum wet bulb temperature, non-condensing.

Operating

Non-operating

3050 m (10,000 ft). This value may be limited by the type and number of options installed.

Maximum allowable altitude change rate is

457 m/min (1500 ft/min).

9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min).

Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels

(LpAm) when the product is operating in a 23°C ambient environment.

Noise emissions were measured in accordance with ISO 7779 (ECMA

74) and declared in accordance with ISO 9296 (ECMA 109).

Idle

LWAd

LpAm

Operating

LWAd

LpAm

5.3 B

38 dBA

5.3 B

38 dBA

NC362i Integrated Dual

Port Gigabit Server

Adapter

Network Interface

Integrated 10/100/1000BASE-T Transceiver

Combines a triple-speed IEEE 802.3TM - Compliant Media Access

Controller (MAC) with a triple-speed Ethernet transceiver.

Data Transfer Method

Compliant to x1 PCIe Specification

Controller

Intel® 82576

Network Transfer Rate 10Base-T (Half-Duplex)

10 Mb/s

10Base-T (Full-Duplex) 20 Mb/s

100 Mb/s 100Base-TX (Half-

Duplex)

100Base-TX (Full-

Duplex)

200 Mb/s

Connector

Cable Support

1000Base-TX (Half and

Full-Duplex)

RJ-45

2000 Mb/s

Performs all the physical layer functions for 10BASE-T, 100BASE-T, and 1000BASE-T Ethernet on standard Category 5 UT

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 56

QuickSpecs

Technical Specifications

HP 160GB 3G SATA

7.2K rpm LFF (3.5-inch)

Entry 1yr Warranty

Hard Drive

458945-B21

Smart Array P212

Controller

160GB 7,200 rpm

HP ProLiant DL180 Generation 6

Capacity

Height

Width

Depth

Interface

Transfer Rate

(Maximum)

Native Command

Queuing

Seek Time

(typical reads, including settling)

160,041MB

1.04 in (26.4 mm)

4.36 in (110.7 mm)

7.25 in (184.2 mm)

Serial ATA

3Gb/s

Supported

Single Track

Average

Full-Stroke

Rotational Speed

2.0 ms

<11 ms

23.0 ms

7,200 rpm

Physical Configuration Bytes/Sector

Logical Blocks

512

312,581,808

Operating Temperature41° to 131° F (5° to 55° C)

Disk Drive and

Enclosure Interface

Server Interface

SAS Speed

Cache Memory

3G SAS (Serial Attached SCSI)

1.5G SATA (Serial ATA)

SAS Connectors

1 internal/1 external (Mini-SAS) x8 wide port connectors

Cache Memory Speed DDR-2/533 MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s

maximum bandwidth.

x8 2.5G PCIe 2.0 provides 2GB/s maximum bandwidth.

x8 3G SAS provides 2.4GB/s maximum bandwidth.

Logical Drives

Supported

40-bit 256MB ECC protected cache; transportable with battery-backed upgrade.

NOTE: The 256MB cache is not battery-backed or transportable.

Up to 32 logical volumes

Host Memory

Addressing

RAID Support

64-bit, supporting greater than 4GB server memory space

RAID 6, 6+0 (Advanced Data Guarding)

NOTE: A minimum of 256 MB cache, battery kit, and Smart Array

Advanced Pack License Key upgrade is required to enable RAID 6, 6+0

RAID 5, 5+0 (Distributed Data Guarding)

NOTE: The 256 MB & Battery Kit upgrade is required to enable RAID 5,

5+0 support

RAID 1, 1+0 (Striping & Mirroring)

RAID 0 (Striping)

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 57

QuickSpecs

HP ProLiant DL180 Generation 6

Technical Specifications

Smart Array P410/410i

Controller

Disk Drive and

Enclosure Interface

6Gb/s SAS (Serial Attached SCSI)

3Gb/s SATA (Serial ATA)

2 internal (Mini-SAS) x8 wide port connectors

SAS Connectors

Cache Memory Speed DDR2-533MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s

maximum bandwidth.

Server Interface

x8 2.5G PCIe 2.0 provides 2GB/s maximum bandwidth

SAS Speed

Cache Memory

x8 6Gb/s SAS provides 24.8GB/s maximum bandwidth

40-bit 256MB ECC protected cache (72-bit 512MB BBWC module upgrades available); transportable with battery-backed upgrade

Up to 64 logical drives

Logical Drives

Supported

Host Memory

Addressing

RAID Support

64-bit, supporting greater than 4GB server memory space

RAID 6, 6+0 (Advanced Data Guarding)

NOTE: The minimum of 256 MB cache, battery kit, and Smart Array

Advanced Pack License Key upgrade is required to enable RAID 6, 6+0

RAID 5, 5+0 (Distributed Data Guarding)

NOTE: The 256 MB is required to enable RAID 5, 5+0 support of the

Smart Array P410i

RAID 1+0 (Striping & Mirroring)

RAID 0 (Striping)

Environment-friendly

Products and

Approach

End-of-life

Management and

Recycling

Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green . To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner.

The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green . These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment.

© Copyright 2010 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice.

Microsoft and Windows NT are US registered trademarks of Microsoft Corporation.

Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries.

The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less.

DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 58

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project