advertisement
QuickSpecs
Overview
HP ProLiant DL180 Generation 6
Front View:
1.
Access panel
2.
Front LED Indicators
3.
Power on/off
4.
Optional DVD-RW or DVD-ROM drive
5.
Front USB Ports (2)
6.
Non-Hot Plug Non Redundant fans (4 fans)
7.
Air Baffle
8.
PCI Cage
9.
System Board
Rear View:
1.
Redundant Power Supply Bay (Optional)
2.
Power Supply Cable Socket
3.
Low Profile Card Slot
4.
PCI Expansion Card Slot
5.
PCI Expansion Card Slot
6.
UID LED Button
7.
(Optional) LO100i 10/100 Mbps LAN port for IPMI management (RJ-45)
8.
LAN Port
9.
LAN Port
10.
2 Rear USB 2.0 Ports
11.
VGA Port
12.
Serial Port
What's New
Announcing support for the Intel® Xeon® processor 5600 series-the next generation of intelligent server processors offering significant performance (up to 40% over single-core processors), power regulation (Low Voltage DIMMs) enhancements
Announcing the new High Efficiency server mode.
Support for 750 W and 460 W Platinum Power Supply
Support for I/O Accelerators
At A Glance
The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellence and 2U density for a variety of rack deployments and applications.
Processors:
Supports up to two Intel® Xeon® Six and Four -Core 5600 sequence processors with up to 12 MB Level 3 cache
Supports up to two Quad-Core Intel® Xeon® processors: 5500 sequence with 8MB Level 3 cache
Intel® 5520 Chipset
Memory:
Up to 12 DIMM slots
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 1
QuickSpecs
HP ProLiant DL180 Generation 6
Overview
Up to 192GB, using 16GB Quad-Rank PC3-8500R-7 DDR3 Registered (RDIMM) memory, operating at 800MHz when fully populated at 2 DIMMs per Channel in 12 slots
Up to 96GB, using PC3-10600R DDR3Registered (RDIMM) memory, operating at 1066MHz when fully populated at 2 DIMMs per Channel in 12 slots.
Up to 48GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fully populated at 2 DIMMs per Channel in 12 slots
NOTE: Half DIMM slots are available when one processor is installed.
Internal Drive Support:
Support for up to twenty-five (25) SFF with a Smart Array controller.
Hot Plug Serial ATA (SATA) Models: Up to 12.5 TB (25 x 500GB Hot Plug 2.5"hard drives)
Hot Plug Serial Attached SCSI (SAS) Models: Up to 12.5 TB ( 25 x 500GB Hot Plug 2.5"hard drives)
Support for up to fourteen (14) LFF with a Smart Array controller:
Hot Plug Serial ATA (SATA) Models: Up to 28.0TB (14 x 2TB Hot Plug 3.5" hard drives)
Hot Plug Serial Attached SCSI (SAS) Models: SAS Model: Up to 28.0TB (14 x 2TB Hot Plug 3.5" hard drives)
NOTE: Four (4), eight (8) and twelve (12) hard drives models are supported standard via BTO. Eight (8) and twelve (12) hard drive model support requires the addition of a Smart Array or HBA controller. Hot
Plug and SAS functionality require the addition of a Smart Array or HBA controller.
Standard model drive bays:
Four (4) 3.5"Large Form Factor (LFF) hot-plug drive bays supporting up to 6Gb/s SAS or 3Gb/s SATA transfer rate.
NOTE: Embedded SATA controller support transfer rate up to 1.5Gb/s SATA. HP Smart Array P212 or
P410 controller is required to achieve 6Gb/s SAS or 3Gb/s SATA transfer rate
Eight (8) 3.5" Large Form Factor (LFF) hot-plug drive bays supporting up to 6Gb/s SAS or 3Gb/s SATA transfer rate.
Twelve (12) 3.5" Large Form Factor (LFF) hot-plug drive bays supporting up to 3Gb/s SAS or 3Gb/s SATA transfer rate.
Optional drive bays:
Twenty Five (25) 2.5" Small Form Factor (SFF) hot-plug drive bays supporting up to 6Gb/s SAS or 3Gb/s
SATA transfer rate.
Eight (8) 2.5" Small Form Factor (SFF) hot-plug drive bays supporting up to 6Gb/s SAS or 3Gb/s SATA transfer rate.
Rear Two (2) 3.5" Large Form Factor (LFF) hot-plug drive bays to use with 12LFF bays supporting up to
3Gb/s SAS or 3Gb/s SATA transfer rate.
NOTE: Full Height/ Full Length Riser Option is not available when the Rear 2LFF drive bays is selected for the system.
NOTE: All Hard drive bay options except 4LFF require HP Smart Array P410 or P212 controller.
NOTE: To achieve highest possible stated transfer rate please make sure the firmware on the drive bays
(backplanes) and HP Smart Array controller up to date. Latest firmware are available to download from HP support web site.
Network Controller:
HP NC362i Integrated Dual Port Gigabit Server Adapter
Storage Controllers:
4 HDD BTO Models: HP Embedded SATA RAID Controller RAID 0,1,10
NOTE: Embedded SATA controller support transfer rate up to 3Gb/s SATA
NOTE: To enable RAID on Embedded SATA, use the HP Smart Array B110i SATA Raid controller, To enable use of the B110i, enter the ROM based setup utility(RBSU). The option for enabling RAID can be found in the
Advanced section of the RBSU
NOTE: For Hot Plug SATA, upgrade to the Smart Array Hot Plug Advance Pack for B110i
8 HDD BTO Models: HP Smart Array P410 /256MB Controller (RAID 0/1/1+0/5/5+0 NOTE: Support speed up to
6Gb/s SAS or 3Gb/s SATA
NOTE: Available upgrades: 512MB with BBWC or FBWC, Battery kit upgrade (for the 256MB cache), and Smart
Array Advanced Pack (SAAP)
12 HDD BTO Models: HP Smart Array P212 /256MB Controller(RAID 0/1/1+0/5/5+0)
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 2
QuickSpecs
HP ProLiant DL180 Generation 6
Overview
NOTE: A minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade is required to enable RAID 6, 6+0 NOTE: Support speed up to 3Gb/s SAS or 3Gb/s SATA
25 HDD BTO Model: HP Smart Array P212/256MB Controller (RAID 0/1/1+0/5/5+0)
NOTE: Available upgrades: P410 with FBWC, 256MB with BBWC, 512MB with FBWC, Battery kit upgrade (for the 256MB cache), and Smart Array Advanced Pack (SAAP). NOTE: Support speed up to 6Gb/s SAS or 3Gb/s
SATA
NOTE: To achieve highest possible stated transfer rate please make sure the firmware on the drive bays
(backplanes) and HP Smart Array controller up to date. Latest firmware are available to download from HP support web site
Expansion Slots:
Up to Four (4) available PCI-Express Slots via the three (3) PCI-E Slot Riser
One available Low Profile x16 PCI-Express slot using a Low profile Riser
One 3PCI-E x8 Full Height Kit, providing 2x8 full length/full height slots as well as an additional x8(x4 electrically
) slot
Two Full Height/ Full Length Riser options:
Option 1: 2 PCIe2x8 and 1 PCIex8(4) full-length/full-height slots (Standard)
Option 2: 2 PCIe2x8 full-length/full-height PCI-Express slots (Optional)
Option 3: 2 PCI-X, full-length/full-height riser Slots(Optional)
Option 4: 1 PCIe2x16 full-length / full-height slot (Optional)
Option 5: 2 PCIe2x8 and 1 PCIex8(4) full-length/full-height slots (Optional)
NOTE: Full Height/ Full Length Riser Option are not available when the Rear DVD or rear 2LFF drive bay are selected for the system. The rear DVD kit includes the riser option
Redundancy:
Fully redundant non-hot plug fans (Optional)
Hot plug power supply with optional redundancy
Power Sources:
Dual Common Slot Bay for Right Sized, Hot plug and Redundant Power
HP 750W CS HE Gold Power Supply (Standard on some models)
HP 460W CS HE Gold Power Supply (Standard on some models)
HP 460 W CS Platinum Power Supply Kit (Standard on some models)
HP 750W CS Platinum Power Supply Kit
Infrastructure Management:
With G6, ProLiant 100-series server administrators are able to deploy and monitor their servers using methods similar to 300 series servers and above. Agents and the Easy Set-up CD are available that provide a user experiences consistent with 300 series and above.
With Easy Set-up CD, customers get SmartStart "like" deployment tools that reduce the time required for server setup and updates. Easy Set-up CDs and their ISO images are provided with each ProLiant G6
100-series server and are used to perform assisted installations for one or two servers. Users performing multi-server installations involving large numbers of servers may require the following deployment tools:
SmartStart Scripting Toolkit - Automated scalable deployment utility
Smart Components - a self-executable software consisting of driver and firmware
With agents and providers, ProLiant 100 series servers get environmental monitoring that is similar and consistent to that of ProLiant 300 series servers and above. This server now offers the HP Insight
Management Agents and HP Insight Management WBEM Providers, two well established sets of management and Internet standards technologies that provide capabilities which provide integration to HP
Systems Insight Manager (SIM).
HP Insight Control for Linux, a product option, delivers essential infrastructure management that can help save time and money by making it easy to deploy, migrate, monitor, control and optimize your IT infrastructure through a single, simple management console. Insight Control for Linux supports Linux-based central management servers.
Ports:
Five USB ports (two front, two rear , one optional internal)
NOTE: In order to utilize the internal USB port the USB cable (P/N: 536769-B21) must be connected to the internal USB header
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 3
QuickSpecs
HP ProLiant DL180 Generation 6
Overview
Optical Drive:
Support for one (optional): DVD-ROM, DVD/CD RW
NOTE: In the12LFF or 25SFF drives bay model Optical drives are required to be installed with rear option kit
(P/N 515826-B21)
Form Factor:
2U rack models
Operating Systems and Virtualization Software:
Supports Windows, RHEL, SLES, VMware, and Citrix XenServer (Retail)
Deployment/Serviceability:
HP ProLiant DL180 G6 models have fixed rails which provide support for racks with round mounting holes and tool-free support for racks with square mounting holes (including Compaq/HP 7000, 9000, 10000 and HP series), with an adjustment range of 26" - 36"
Tool-less access to all system components for easy in rack serviceability
Customer Self Repair (CSR): HP products are designed with many CSR parts to minimize repair time and allow for greater flexibility in performing defective parts replacement
Warranty:
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of
HP Authorized Channel Partners. Hardware diagnostic support and parts replacement is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. Hard drives have either a one year or three year warranty; refer to the specific hard drive
QuickSpecs for details.
NOTE: Server Warranty includes 3-Years Next Business Day Parts replacement, 0-Years Labor, 0-Years Onsite support. Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 4
QuickSpecs
Standard Features
HP ProLiant DL180 Generation 6
NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information -
Factory Integrated Models" section.
Processor
One of the following depending on Model
Six-Core Processors
Intel® Xeon® Processor X5670 (2.93 GHz, 12MB L3 Cache, 95W, DDR3-1333, HT, Turbo
2/2/2/2/3/3) FIO
NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.
Intel® Xeon® Processor X5660 (2.80 GHz, 12MB L3 Cache, 95W, DDR3-1333, HT, Turbo
2/2/2/2/3/3) FIO
NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.
Intel® Xeon® Processor X5650 (2.66 GHz, 12MB L3 Cache, 95W, DDR3-1333, HT, Turbo
2/2/2/2/3/3) FIO
Intel® Xeon® Processor L5640 (2.26GHz, 12MB L3 Cache, 60W, DDR3-1333, HT, Turbo
2/2/3/3/4/4) FIO
NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.
Quad -Core Processors
Intel® Xeon® Processor E5640 (2.66 GHz, 12MB L3 Cache, 80W, DDR3-1066, HT, Turbo
1/1/2/2) FIO
NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.
Intel® Xeon® Processor E5630 (2.53 GHz, 12MB L3 Cache, 80W, DDR3-1066, HT, Turbo
1/1/2/2) FIO
NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.
Intel® Xeon® Processor E5620 (2.40 GHz, 12MB L3 Cache, 80W, DDR3-1066, HT, Turbo
1/1/2/2) FIO
Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO
Intel® Xeon® Processor L5630 (2.13 GHz, 12M L3 Cache, 40W, DDR3-1066, HT, Turbo 1/1/2/2/)
FIO
NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.
Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800)
Intel® Xeon® Processor L5630 (2.13 GHz, 12ML L3 Cache, 40W, DDR3-1066, HT, Turbo
1/1/2/2/) FIO
NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.
Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)
Two -Core Processors
Intel® Xeon® Processor E5503 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) FIO
NOTE: Available through Configure To Order only. See Factory Integration Models section for more details.
NOTE: HT indicates that the processor model supports Intel® Hyper-Threading Technology.
NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 5
QuickSpecs
Standard Features
HP ProLiant DL180 Generation 6
Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5000 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes
Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage.
Upgradeability
Chipset
Upgradeable to two processors
Intel® 5520 Chipset
NOTE: For more information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/ .
Cache Memory
Memory Protection
Advanced memory protection
Mirroring Mode
Lockstep Mode
Memory
12 MB Level 3 cache (L5630,E5620,X5650)
4 MB Level 3 cache (E5506)
Type
Standard (Entry Models)
Standard (Base Models)
DDR3 Registered (RDIMM) or Unbuffered (UDIMM)
4GB (1 x 4GB)
8GB (2 x 4GB)
16GB (4 x 4GB) Standard (Performance
Models)
Maximum (RDIMM) 192GB (12 x 16GB)
Maximum (UDIMM) 48GB (12 x 4GB)
NOTE: Depending on the memory configuration and processor model, the memory speed may run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration Tool at: www.hp.com/go/ddr3memory-configurator .
DDR3 memory options part number decoder
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 6
QuickSpecs
Standard Features
HP ProLiant DL180 Generation 6
Network Controller
HP NC362i Integrated Dual Port Gigabit Server Adapter
Expansion Slots
Storage Controller
Slot Number Bus Speed Bus Number
*
Device
Number
**
0
Hot Plug
(Y/N)
N
Notes
1 x16 PCI-
Express x8 PCI-Express
6 Low Profile
2
3
4
2
3 x8 PCI-Express x4 PCI-Express
PCI-X
PCI-X
***
***
5
4
3
Dynamic
Dynamic
0
0
0
1
2
N
N
N
N
N
Full Length
Full Height
Full Length
Full Height
Full Length
Full Height
Full Length
Full Height
Full Length
Full Height
NOTE: All slots can accept universal keyed PCI cards.
NOTE: Support is limited to PCI-X cards only.
* Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number.
** Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest
Device ID by bus (starting with the lowest bus).
*** PCI-X bus speed will be 100MHz in maximum and support two PCI-X/100MHz cards.
**** Slot 2 contains bus 4 and bus 5 because BIOS configures this x16 PCI-express.
NOTE: PCI-X support is limited to PCI-X cards only.
NOTE: Slot to two x8 PCI-express slot for production riser, this is valid only on Option1: 2
PCIe2x8 full-length/full-height PCI-Express slots (Optional) or Option 4: 2 PCIe2x8 and 1 PCIex8
(4) full-length/full-height slots (Optional).
4HDD Models
8HDD Models
12HDD Models
HP Smart Array B110i SATA RAID
NOTE: To enable RAID on Embedded SATA, use the HP Smart Array
B110i SATA RAID Controller, To enable use of the B110i, enter the
ROM based setup utility(RBSU). The option for enabling RAID can be found in the Advanced section of the RBSU.
NOTE: Embedded SATA controller support transfer rate up to 3Gb/s
NOTE: A diskette drive or virtual FDD using LO100 Advanced Pack is needed to install storage controller drivers during a Windows operating system installation from a CD.
HP Smart Array P410/256MB Controller (RAID 0/1/1+0/5/5+0)
NOTE: Support transfer rate up to 6Gb/s SAS or 3Gb/s SATA
HP Smart Array P212/256MB Controller (RAID 0/1/1+0/5/5+0)
NOTE: Available upgrades: P410 with FBWC, 256MB with BBWC,
512MB with FBWC, Battery kit upgrade (for the 256MB cache), and
Smart Array Advanced Pack (SAAP).
NOTE: Support transfer rate up to 3Gb/s SAS or 3Gb/s SATA
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 7
QuickSpecs
Standard Features
HP ProLiant DL180 Generation 6
25HDD Models HP Smart Array P410/256MB Controller (RAID 0/1/1+0/5/5+0)
NOTE: Available upgrades: P410, 512MB with FBWC, Battery kit upgrade (for the 256MB cache), and Smart Array Advanced Pack
(SAAP).
NOTE: Support transfer rate up to 6Gb/s SAS or 3Gb/s SATA
NOTE: A minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade (P/N: 516471-B21) is required to enable RAID 6, 6+0
NOTE: To achieve highest possible stated transfer rate please make sure the firmware on the drive bays (backplanes) and HP Smart Array controller up to date. Latest firmware is available to download from HP support web site.
Storage
Diskette Drives
Optical Drives
Drive Bays
Maximum Internal
Storage
Hot Plug 3.5" SATA
Hot Plug 3.5" SAS
Hot Plug 2.5" SATA
Hot Plug 2.5" SAS
28.0TB (14 x 2TB)
28.0TB (14 x 2TB)
12.5TB (25 x 500GB)
12.5TB (25 x 500GB)
Interfaces
Via USB only
Optional HP Slim SATA DVD-ROM Optical Drive
Optional HP Slim SATA DVD RW Optical Drive
NOTE: Support in 4, 8, and 12 drive models. Optical drives can only be installed in 12 drive model and 25SFF drive bay system with rear option kit (P/N 515826-B21).
Up to 14 Hot Plug SAS/SATA 3.5" drives
Up to 25 Hot Plug SAS/SATA 2.5" drives
NOTE: 4 Drive Models are Non-Hot Pluggable. Smart Array Controller must be added for Hot Plug drive capability. 4 Drive Models can be upgraded with the addition of a Smart Array Controller and a SAS/SATA
Multi-lane cable (496013-B21).
NOTE: The addition of a Smart Array Controller requires the addition of a SAS/SATA Multi-lane cable (P/N 496013-B21).
Graphics
Network RJ-45
(Ethernet)
Serial
Graphics
USB
1
1
2 10/100/1000 NIC ports (plus 1 dedicated for the HP ProLiant Lights
Out 100i Remote Management)
5 total ports: (2) front, (2) rear, (1) optional internal
NOTE: In order to connect a USB device internally, the internal USB
Cable G6 Kit must be used (P/N 536769-B21).
NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usbsupport.html
.
32MB* shared supporting all display resolutions up to 1600x1200 16bpp@75Hz
NOTE: 8MB is dedicated to video memory.
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 8
QuickSpecs
Standard Features
Form Factor
Rack (2U), (3.5 in/8.89 cm)
HP ProLiant DL180 Generation 6
Embedded
Manageability
HP Lights-Out 100
(LO100) Advanced
HP Lights-Out 100, simplifies server setup, control, and lights-out remote administration of ProLiant 100 Series servers and functions without additional software. It can be accessed from any location via
LAN or Internet and works hand-in-hand with HP Systems Insight
Manager (SIM), helping customers unlock the value of the ProLiant platform and deliver the highest possible quality of IT service to the business. Advanced Licenses are required for Virtual KVM and Virtual
Media feature activation.
Key features of LO100 are:
IPMI 2.0 & SMASH CLP support
ROM Setup Utility
Improvements to virtual media with the addition of USB 2.0 drives and protocol support for much faster transfer speeds and DVD-
ROM support plus simplified virtual media (floppy and CD with no
FTTP server requirements)
Enhanced browser interface and embedded KVM over IP provides
OS-independent remote graphical console
24x7 Technical Support and Update (TSU) 1 year support and license upgrades included in Advanced license
HP Insight Control management software
HP Insight Control for
Linux
NOTE: For more information, see: http://www.hp.com/go/lo100
HP Insight Control for Linux, as a product option, delivers essential infrastructure management that can help save time and money by making it easy to deploy, monitor, remote control, and optimize your IT infrastructure through a single, simple management console. The Insight
Control for Linux installs and license software modules that are integrated into HP System Insight Manager.
The HP Insight Control for Linux (IC-Linux) serves environments requiring a Linux-based management consoles. See www.hp.com/go/iclinux
Insight Control server deployment
HP Insight Control include one year of 24 x 7 HP Software Technical
Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/insight
HP Insight Control server deployment is a deployment solution for HP
ProLiant and Integrity servers hosted on a Windows CMS. It automates the process of deploying and provisioning server software, enabling companies to quickly and easily adapt to changing business demands.
Insight Control server deployment includes software optimizations for
HP servers, including the HP scripting toolkits, configuration jobs for leading industry-standard operating systems, sample unattended files, and HP server support packs that include software drivers, management agents, and important documentation. Deploying servers can be accomplished either through imaging or through scripting.
Insight Control server deployment is hosted on a Windows server and is intended for heterogeneous environments deploying Windows, Linux,
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 9
QuickSpecs
Standard Features
Core Server
Management
HP ProLiant DL180 Generation 6
VMware ESX and Microsoft Hyper-V systems.
Insight Control server deployment includes one year of 24 x 7 HP
Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/insight .
ProLiant 100 Series G6
Core Management
Software
HP provides management solutions that are designed to simplify a server's installation, configuration, and maintenance throughout the entire server lifecycle. This provides the customers with higher levels of operational efficiency and highly reliable systems.
While ProLiant 100 series G6 servers do not support the Insight
Foundation Suite for ProLiant, they support a key subset of this important suite software tools and utilities which are very suitable for this class of server: SIM, SMH, agents, providers, and a SmartStart 'like' deployment CD called Easy Set-up which greatly simplifies server setup. Additionally the DL100 and SL100 G6 models support the
SmartStart Scripting Toolkit (SSSTK), an automated scalable deployment utility.
HP Systems Insight
Manager
Insight Management
Agents
Information on core management supported on ProLiant 100 series G6 servers can be found at these URLS:
Core Management: www.hp.com/go/coremanagement
HP ProLiant 100 series Easy Set-up CDs: www.hp.com/servers/easysetup
HP Systems Insight Manager (HP SIM) provides a unified, secure and extensible standards-based environment to centrally manage servers, storage and other infrastructure devices, (both HP and non-HP) across multiple operating system platforms.
HP Insight Management Agents and Insight Management
Providers are available for HP Systems Insight Manager (SIM)
Integration.
ProLiant 100-series G6 servers can use the same SNMP based
Insight Management Agents supported by other ProLiant servers.
As a result, administrators can use HP Systems Insight Manager
(SIM) 5.3 and greater to manage ProLiant 100-series G6 servers.
Administrators can also use any other SNMP- based management tool. These agents are obtained as part of the ProLiant 100-series model-specific "Easy Set-up" CDs, or through: www.hp.com/servers/easysetup
The following capabilities are enabled on the 100-series G6 servers by the SNMP agents:
Health monitoring capabilities, including monitoring for drives, fans, network, power supplies, and temperature
Alerting capabilities, including basic alert notification for Smart
Array drive pre-failure only
Performance monitoring capabilities providing information on
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 10
QuickSpecs
Standard Features
HP ProLiant DL180 Generation 6
Easy Set-up CD
SmartStart Scripting
Toolkit (SSSTK)
processor, memory, disk free space, network utilization
NOTE: For additional information, please see: http://www.hp.com/go/insight
Easy Set-up CDs are available on all 100-series G6 servers and are also available as an ISO image web download. HP ProLiant Easy Setup CDs provide easy, step-by-step, single and multi-server server utilities for the ProLiant 100-series G6 servers to streamline server setup for 100-series G6 servers. The user experience is consistent with
SmartStart and offers the following capabilities:
Boot environment and GUI
Assisted Installation: Windows 2003 Server and Windows 2008
Server drivers
Manual installation: Windows 2003 Server, Windows 2008 Server, and Linux drivers (specific OS support varies by server. Refer to each server's QuickSpecs for supported versions)
HP Insight Diagnostics
AutoRun
Array Configuration Utility (ACU) has been combined with Array
Diagnostics Utility (ADU) to offer both configuration of array controllers and storage devices and testing of array controller hardware
SmartStart Scripting Toolkit (SSSTK) and Smart Components for software and drivers for DL100 and SL100 servers
NOTE: OS and SW available for Manual Installation are listed on each servers' QuickSpecs.
The SmartStart Scripting Toolkit is a server deployment product that delivers an unattended automated installation for high-volume server deployments. The SmartStart Scripting Toolkit includes a set of utilities for configuring and deploying servers in a customized, predictable, and unattended manner. These utilities enable you to duplicate the configuration of a source server on target servers with minimum user interaction.
The Toolkit is designed for IT experts with experience in scripting operating system installations and configuring ProLiant server hardware.
NOTE: For additional information, please see: http://h18004.www1.hp.com/products/servers/management/toolkit/ index.html
Subscriber's Choice
Subscriber's Choice Driver and Support Alerts/Notifications is a webbased email subscription service that provides software and driver change notifications for ProLiant products. Sign up at: http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis.
ROMPaq, software and latest drivers
The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options; downloaded from Software and
Drivers download pages website at: http://www.hp.com/go/support and from www.hp.com/servers/easysetup . Contains the following:
HP Insight Management Agents for Systems Insight Manager
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 11
QuickSpecs
Standard Features
HP ProLiant DL180 Generation 6
(SIM) Integration
HP Systems Management Homepage
Array Configuration Utility (ACU)
Array Diagnostics Utility (ADU)
HP Insight Diagnostics
Industry Standard
Compliance
Security
ACPI V2.0 Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Microsoft® Logo certifications
IPMI 2.0 Compliant
Power-on password
Setup password
Diskette boot control
Secure Sockets Layer (SSL)
Secure Shell (SSH)
Security - Trusted
Platform Module
The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to authenticate the server platform. These artifacts can include passwords, certificates and encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a
Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user data and to ensure that a server running Windows Server 2008 has not been tampered with while the system was offline.
NOTE: For more information about TPM, including a white paper, go to www.hp.com/go/TPM
NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment.
NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing the key could result in data loss.
Server Power Cords
One 6' Highline (IEC-IEC) power cord ships standard
NOTE: HP ProLiant DL servers no longer ship standard with NEMA power cords (P/N 163719-
002) that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected to PDU's in data center racks so they now ship standard with a PDU power cord (416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle
(NEMA-15), the NEMA power cord (P/N 227099-001) must be ordered separately.
If customers require a local power cord, they can check the power cord matrix for the appropriate cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix
NOTE: Rack models ship standard with an IEC cable.
Localized cables included with geographic specific models in other world regions.
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 12
QuickSpecs
HP ProLiant DL180 Generation 6
Standard Features
UPS and PDU Power
Cord Matrix
Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page.
Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords .
Power Supply
HP has a new design for ProLiant power. The new Common Slot Power Supply bay. This design provides the customer with commonality in power supplies across multiple platforms to save on the cost of spares and allows HP to offer multiple power solutions to fit the customers' needs.
Many HP ProLiant Servers come with Common Slot, High Efficiency and Right-Size Power
Supplies. Common Slot (CS) designates commonality of the power supply across multiple
ProLiant servers. HP's new Common Slot power supplies are designed for highest efficiency to provide power efficiency without degrading performance of the ProLiant. Power Supplies will have efficiency ratings up to 92%. There are three Right Size power options available, depending on the configuration of your server. To make sure you select the correct power supply to meet your configuration, we suggest that you use the HP Power Advisor to decide the "Right-Size" for your configuration. All HP Common Slot power sources are UL, CE Mark Compliant, Hot Plug and
Redundant.
Common Slot ProLiant It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power
supply for your needs. HP offers Power Supply Options:
460Watts, Common Slot, 92% Efficiency
750Watts, Common Slot, 92% Efficiency
460Watts, Common Slot, 94% Efficiency
750Watts, Common Slot, 94% Efficiency
HP's ProLiant Common Slot Power supplies (460W & 750W) meet multiple Energy Efficiency
Initiatives. Climate Savers Computing Initiative GOLD, ECOS Consulting 80PLUS GOLD and plans on offering models that meet the Energy Star for Server requirements when they are published.
HP's ProLiant Common Slot Power supplies (1200W) meet multiple Energy Efficiency Initiatives.
Climate Savers Computing Initiative Bronze, ECOS Consulting 80PLUS Bronze Power Supply requirements.
Redundant Power: Optional (1+ 1 or n+n redundant) power supplies can be purchased through power supply option kits.
System Fans
4 system fans ship standard; Non-hot plug, Non-redundant
NOTE: Redundant fan kit (P/N 516009-B21) available for purchase.
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 13
QuickSpecs
HP ProLiant DL180 Generation 6
Standard Features
Operating Systems and
Microsoft Windows Server
Virtualization Software
Support for ProLiant
Servers
Microsoft Windows Server Hyper-V
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
VMware ESX Server
Citrix Essentials for XenServer (Retail)
NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and
Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/supportos and our driver download page http://www.hp.com/support/DL180G6
Rack Airflow
Requirements
Rack 10000 G2 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow
830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm).
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack.
This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.
Rack Kit
HP ProLiant DL180 rack models have fixed rails which provide support for racks with round mounting holes and tool-free support for racks with square mounting holes (including Compaq/HP
7000, 9000, 10000 and HP series), with an adjustment range of 26" - 36".
Telco Rack Support
Support for all 2 and 4 post Telco racks and threaded hole racks requires an additional option kit from Rack Solutions. The Rack Solutions brackets can be purchased at: www.hp.com/go/rackandpower .
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 14
QuickSpecs
HP ProLiant DL180 Generation 6
Standard Features
Factory Express
Portfolio for Servers and Storage
HP Factory Express offers configuration, customization, integration and deployment services for
HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP
BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server model please contact your sales representative or go to: http://www.hp.com/go/factory-express .
HP Enterprise
Configurator
HPC Interconnect
The HP eConfigure Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact
HP's Customer Business Center or an Authorized Partner for assistance.
http://www.hp.com/products/configurator .
NOTE: High Performance Computing (HPC) interconnect technologies are available for this server under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC
Clusters with InfiniBand or Gigabit Ethernet: http://www.hp.com/techservers/clusters/ucp/index.html
InfiniBand
PCI-Express Generation 2 adapters
Service and Support
HP services provide total care and support expertise with committed response designed to meet your IT and business needs.
HP Care Pack services include coverage for the HP branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to 3kVA; these items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack.
To fully capitalize on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime.
Recommended Service - Simplify ProLiant solution implementation, maintenance and
management.
Support Service - 3-Year 24x7 4 hr Response service support coverage
Deployment Service - Hardware Installation
Enhanced Service - Optimize service level to increase IT performance and availability
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 15
QuickSpecs
Standard Features
HP ProLiant DL180 Generation 6
Support Service - 3-Year 24x7 24 hr Call to repair service support coverage
Support- - 3-Year 24x7 6 hr Call to repair service support coverage
Support Plus - 24x7 4 hr Response service support including OS coverage
Installation of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or
Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays.
For a complete listing of service offerings and information visit: http://www.hp.com/services/proliantservices http://h20219.www2.hp.com/services/us/en/warranty/carepack-servers-proliant.html
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 16
QuickSpecs
Models
HP ProLiant DL180 Generation 6
Four Drive Serial ATA (SATA) Models
NOTE: Upgrading from 4 Non-Hot Plug SATA hard drives to 4 Hot Plug SATA/SAS hard drives requires the addition of a storage controller and one Internal mini-SAS cable (P/N 496013-B21).
NOTE: Upgrading to 8 Hot Plug SATA/SAS hard drives requires the addition of a HP 2U G6 8HDD LFF DL18X KIT (P/N
506924-B21), storage controller (Smart Array P410/256MB recommended), and two Internal SATA/SAS cables (mini-SAS cable (P/N 496013-B21).
HP DL180G6 E5504
2x2GB 4LFF
487502-xx1
Processor
Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W,
DDR3-800)
Cache Memory
Memory
4MB shared L3 cache (E5504)
4GB (2 x 2GB) PC3-10600E (UDIMM)
Network Controller
Storage Controller
Hard Drive
Internal Storage
Optical Drive
Power Supply
Form Factor
HP NC362i Integrated Dual Port Gigabit Server Adapter
Embedded SATA Raid Standard RAID 0,1,10
1x 160GB Hot Plug SATA
NOTE: Hot-plug functionality requires the addition of a Smart Array controller.
8.0TB (4 x 2TB Hot Plug 3.5" SATA hard drives), Maximum
8.0TB (4 x 2TB Hot Plug 3.5" SAS hard drives), Maximum
None ship standard
460W common slot, high efficiency power supply
Rack (2U)
HP DL180G6 L5520
2x2GB 4LFF
487506-xx1
Processor
Cache Memory
Memory
Network Controller
Storage Controller
Hard Drive
Internal Storage
Optical Drive
Power Supply
Form Factor
Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W,
DDR3-1066, HT, Turbo 1/1/2/2)
8MB shared L3 cache (L5520)
4GB (2 x 2GB) PC3-10600E (UDIMM)
HP NC362i Integrated Dual Port Gigabit Server Adapter
Embedded SATA Raid Standard RAID 0,1,10
1x 160GB Hot Plug SATA
NOTE: Hot-plug functionality requires the addition of a Smart Array controller.
8.0TB (4 x 2TB Hot Plug 3.5" SATA hard drives), Maximum
8.0TB (4 x 2TB Hot Plug 3.5" SAS hard drives), Maximum
None ship standard
460W common slot, high efficiency power supply
Rack (2U)
HP DL180G6 E5506
1x4GB 4LFF
590637-xx1
Processor
Cache Memory
Memory
Network Controller
Storage Controller
Hard Drive
Internal Storage
Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W,
DDR3-800)
4MB shared L3 cache (E5506)
4GB (1 x 4GB) PC3-10600R-9 (RDIMM)
HP NC362i Integrated Dual Port Gigabit Server Adapter
HP Smart Array B110i SATA RAID Controller
None Ship Standard
8.0TB (4 x 2TB Hot Plug 3.5" SATA hard drives), Maximum
8.0TB (4 x 2TB Hot Plug 3.5" SAS hard drives), Maximum
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 17
QuickSpecs
Models
Optical Drive
Power Supply
Form Factor
HP ProLiant DL180 Generation 6
None ship standard
460W common slot, high efficiency power supply
Rack (2U)
Eight Drive Serial ATA (SATA) Models
NOTE: Supports up to 8 Hot Plug SATA or SAS Hard Drives.
Processor HP DL180G6 E5620
2x4GB 8LFF
590638-xx1
Cache Memory
Memory
Network Controller
Storage Controller
Hard Drive
Internal Storage
Optical Drive
Power Supply
Form Factor
Intel® Xeon® Processor E5620 (2.4 GHz, 12MB L3 Cache, 80W,
DDR3-1066, HT, Turbo 1/1/2/2)
8MB shared L3 cache
8GB (2 x 4GB) PC3-10600R-9 (RDIMM)
HP NC362i Integrated Dual Port Gigabit Server Adapter
HP Smart Array P410/256MB BBWC Controller (RAID 0/1/1+0/5/5+0)
NOTE: Smart Array Advanced Pack License Key upgrade (P/N 516471-
B21) is required to enable RAID 6, 6+0
None ship standard
16.0TB (8 x 2TB Hot Plug 3.5" SATA hard drives), Maximum
16.0TB (8 x 2TB Hot Plug 3.5" SAS hard drives), Maximum
None ship standard
460W common slot, high efficiency power supply
Rack (2U)
HP DL180G6 E5520
3x2GB 8LFF
487503-xx1
Processor
Cache Memory
Memory
Network Controller
Storage Controller
Hard Drive
Internal Storage
Optical Drive
Power Supply
Form Factor
Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W,
DDR3-1066, HT, Turbo 1/1/2/2)
8MB shared L3 cache
6GB (3 x 2GB) PC3-10600E (UDIMM)
HP NC362i Integrated Dual Port Gigabit Server Adapter
HP Smart Array P410 /256MB Controller (RAID 0/1/1+0/5/5+0)
NOTE: A minimum of 256 MB cache, battery kit, and Smart Array
Advanced Pack License Key upgrade (P/N 516471-B21) is required to enable RAID 6, 6+0
None ship standard
16.0TB (8 x 2TB Hot Plug 3.5" SATA hard drives), Maximum
16.0TB (8 x 2TB Hot Plug 3.5" SAS hard drives), Maximum
None ship standard
460W common slot, high efficiency power supply
Rack (2U)
HP DL180G6 L5630 1x4
GB 8LFF
590636-xx1
Processor
Cache Memory
Memory
Network Controller
Intel® Xeon® Processor L5630 (2.13 GHz, 12M L3 Cache, 40W, DDR3-
1066, HT, Turbo 1/1/2/2)
12MB shared L3 cache
4GB (1 x 4GB) PC3L-10600R-9 (RDIMM)
HP NC362i Integrated Dual Port Gigabit Server Adapter
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 18
QuickSpecs
Models
Storage Controller
Hard Drive
Internal Storage
Optical Drive
Power Supply
Form Factor
HP ProLiant DL180 Generation 6
HP Smart Array P410 /256MB Controller (RAID 0/1/1+0/5/5+0)
NOTE: A minimum of 256 MB cache, battery kit, and Smart Array
Advanced Pack License Key upgrade (P/N 516471-B21) is required to enable RAID 6, 6+0
None ship standard
16.0TB (8 x 2TB Hot Plug 3.5" SATA hard drives), Maximum
16.0TB (8 x 2TB Hot Plug 3.5" SAS hard drives), Maximum
None ship standard
460W common slot, high efficiency Platinum power supply
Rack (2U)
Twelve Drive Serial ATA (SATA) Models
NOTE: Internal Storage expandable to 14 SAS/SATA drives with 2 Rear Drive Option Kit (P/N 488234-B21)
HP DL180G6 E5620
2x4GB 12LFF US
590639-xx1
Processor
Intel® Xeon® Processor E5620 (2.4 GHz, 12MB L3 Cache, 80W,
DDR3-1066, HT, Turbo 1/1/2/2)
Cache Memory
Memory
12MB shared L3 cache
8GB (2 x 4GB) PC3-10600R-9 (RDIMM)
Network Controller
Storage Controller
Hard Drive
Internal Storage
Optical Drive
Power Supply
Form Factor
HP NC362i Integrated Dual Port Gigabit Server Adapter
HP Smart Array P212 /256MB BBWC Controller (RAID 0/1/1+0/5/5+0)
NOTE: Smart Array Advanced Pack License Key upgrade (P/N 516471-
B21) is required to enable RAID 6, 6+0
None ship standard (up to 12 Hot Plug SATA or SAS drives supported)
24.0TB (12 x 2TB Hot Plug 3.5" SATA hard drives), Maximum
24.0TB (12 x 2TB Hot Plug 3.5" SAS hard drives), Maximum
NOTE: Internal Storage expandable to 14 SAS/SATA drives with 2 Rear
Drive Option Kit (P/N 488234-B21)
None ship standard
750W common slot, high efficiency power supply
Rack (2U)
HP DL180G6 E5540
6x2GB 12LFF US
487507-xx1
Processor
Cache Memory
Memory
Network Controller
Storage Controller
Hard Drive
Internal Storage
Optical Drive
Power Supply
(2) Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W,
DDR3-1066, HT, Turbo 1/1/2/2)
8MB shared L3 cache
12GB (6 x 2GB) PC3-10600R (RDIMM)
HP NC362i Integrated Dual Port Gigabit Server Adapter
HP Smart Array P212 /256MB Controller (RAID 0/1/1+0/5/5+0)
NOTE: The minimum of 256 MB cache, battery kit, and Smart Array
Advanced Pack License Key upgrade (P/N 516471-B21) is required to enable RAID 6, 6+0
None ship standard (up to 12 Hot Plug SATA or SAS drives supported)
24.0TB (12 x 2TB Hot Plug 3.5" SATA hard drives), Maximum
24.0TB (12 x 2TB Hot Plug 3.5" SAS hard drives), Maximum
NOTE: Internal Storage expandable to 14 SAS/SATA drives with 2 Rear
Drive Option Kit (P/N 488234-B21)
None ship standard
750W common slot, high efficiency power supply
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 19
QuickSpecs
Models
Form Factor
HP ProLiant DL180 Generation 6
Rack (2U)
HP DL180G6 E5520
3x2GB 12LFF
487508-xx1
Processor
Cache Memory
Memory
Network Controller
Storage Controller
Hard Drive
Internal Storage
Optical Drive
Power Supply
Form Factor
Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W,
DDR3-1066, HT, Turbo 1/1/2/2)
8MB shared L3 cache
6GB (3 x 2GB) PC3-10600E (UDIMM)
HP NC362i Integrated Dual Port Gigabit Server Adapter
HP Smart Array P212 /256MB Controller (RAID 0/1/1+0/5/5+0)
NOTE: The minimum of 256 MB cache, battery kit, and Smart Array
Advanced Pack License Key upgrade (P/N 516471-B21) is required to enable RAID 6, 6+0
None ship standard (up to 12 Hot Plug SATA or SAS drives supported)
24.0TB (12 x 2TB Hot Plug 3.5" SATA hard drives), Maximum
24.0TB (12 x 2TB Hot Plug 3.5" SAS hard drives), Maximum
NOTE: Internal Storage expandable to 14 SAS/SATA drives with 2 Rear
Drive Option Kit (P/N 488234-B21)
None ship standard
750W common slot, high efficiency power supply
Rack (2U)
Twenty Five Drive SAS Models
HP DL180G6 X5650
4x4GB 25SFF US
590640-xx1
Processor
Cache Memory
Memory
Network Controller
Storage Controller
Hard Drive
Internal Storage
Optical Drive
Power Supply
Form Factor
(2) Intel® Xeon® Processor X5650 (2.66 GHz, 12MB L3 Cache, 95W,
DDR3-1333, HT, Turbo 2/2/3/3)
12MB shared L3 cache
16GB (4 x 4GB) PC3-10600R-9 (RDIMM)
HP NC362i Integrated Dual Port Gigabit Server Adapter
HP Smart Array P410/256MB BBWC Controller (RAID 0/1/1+0/5/5+0)
NOTE: Smart Array Advanced Pack License Key upgrade (P/N 516471-
B21) is required to enable RAID 6, 6+0
None Ship Standard
12.5TB (25 x 500GB Hot Plug 2.5" SATA hard drives), Maximum
12.5TB (25 x 500GB Hot Plug 2.5" SAS hard drives), Maximum
None ship standard
750 W common slot ,power supply
Rack (2U)
Country Code Key
xx=00 xx=29 xx=37 xx=42 xx=AA
U.S.
Japan
APD
Europe
PRC
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 20
QuickSpecs
Configuration Information - Factory Integrated Models
HP ProLiant DL180 Generation 6
NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO product offerings and requirements.
NOTE: HP does not allow factory integration of options into standard models listed above.
Configure-to-order servers must start with a CTO Chassis.
NOTE: FIO indicates that this option is a Factory Installable Option.
Step 1: Base Configuration (choose one of the following configurable models)
Hot Plug LFF Models
HP ProLiant DL180 G6 Hot Plug SAS/SATA Rack CTO Chassis 507168-B21
Factory Integrated Model ships with:
HP NC362i Integrated Dual Port Gigabit Server Adapter
Three available PCI-Express slots:
Slot 1: x16 low-profile/half-height slot
Optional Slots 2, 3, & 4: 2x8 full-height/full length, 1x4 full-height/full length
(Recommended)
NOTE: Optional PCI-X option kit includes: Slot 1 and 2: full-length/full-height
PCI-X 100. PCI-X slots are 64 bits; 133 MHz capable if only one PCI-X card is installed in the server.
NOTE: Optional FL/FH option kit includes: Slot 1: full length/full height slot.
One HP SATA Embedded Cable Kit
One Highline IEC Power Cord
4 Non-Hot Plug Fans
Rack (2U), (3.5 in/8.89 cm)
Tool-less Fixed Rails
Hot Plug SFF Models
HP ProLiant DL180 G6 Hot Plug SAS/SATA Rack CTO Chassis
Factory Integrated Model ships with:
HP NC362i Integrated Dual Port Gigabit Server Adapter
Three available PCI-Express slots:
Slot 1: x16 low-profile/half-height slot
Optional Slots 2, 3, & 4: 2x8 full-height/full length, 1x4 full-height/full length
(Recommended)
NOTE: Optional PCI-X option kit includes: Slot 1 and 2: full-length/full-height
PCI-X 100. PCI-X slots are 64 bits; 133 MHz capable if only one PCI-X card is installed in the server.
NOTE: Optional FL/FH option kit includes: Slot 1: full length/full height slot.
One HP SATA Embedded Cable Kit
One Highline IEC Power Cord
4 Non-Hot Plug Fans
Rack (2U), (3.5 in/8.89 cm)
594911-B21
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 21
QuickSpecs
HP ProLiant DL180 Generation 6
Configuration Information - Factory Integrated Models
Step 2: Choose Required Options (only one of the following from each list unless otherwise noted)
HP Processors
NOTE: If 2 processors are desired, select one xxxxxx-L21 and one xxxxxxB21.
Six-Core Processors
Intel® Xeon® Processor X5670 (2.93 GHz, 12MB L3 Cache, 95W, DDR3-1333,
HT, Turbo 2/2/2/2/3/3), FIO
Intel® Xeon® Processor X5660 (2.80 GHz, 12MB L3 Cache, 95W, DDR3-1333,
HT, Turbo 2/2/2/2/3/3), FIO
Intel® Xeon® Processor X5650 (2.66 GHz, 12MB L3 Cache, 95W, DDR3-1333,
HT, Turbo 2/2/2/2/3/3), FIO
Intel® Xeon® Processor L5640 (2.26GHz, 12MB L3 Cache , 60W, DDR3-1333,
HT, Turbo 2/2/3/3/4/4), FIO
Quad-Core Processors
Intel® Xeon® Processor E5640 (2.66 GHz, 12MB L3 Cache, 80W, DDR3-1066,
HT, Turbo 1/1/2/2), FIO
Intel® Xeon® Processor E5630 (2.53 GHz, 12MB L3 Cache, 80W, DDR3-1066,
HT, Turbo 1/1/2/2), FIO
Intel® Xeon® Processor E5620 (2.40 GHz, 12MB L3 Cache, 80W, DDR3-1066,
HT, Turbo 1/1/2/2), FIO
Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066,
HT, Turbo 1/1/2/2), FIO
Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066,
HT, Turbo 1/1/2/2), FIO
Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800),
FIO
Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800),
FIO
Intel® Xeon® Processor L5630 (2.13 GHz, 12MB L3 Cache, 40W, DDR3-1066,
HT, Turbo 1/1/2/2), FIO
Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066,
HT, Turbo 1/1/2/2), FIO
Dual-Core Processor
Intel® Xeon® Processor E5503 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800),
FIO
590619-L21
590617-L21
590615-L21
590607-L21
590613-L21
590611-L21
590609-L21
508343-L21
508342-L21
573909-L21
508341-L21
590605-L21
508344-L21
594118-L21
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 22
QuickSpecs
HP ProLiant DL180 Generation 6
Configuration Information - Factory Integrated Models
HP Memory Registered RDIMMs
HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9
Memory Kit
HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9
Memory Kit
HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low
Power Memory Kit
HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9
Memory Kit
HP 8GB (1x8GB) Dual Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7
Memory Kit
HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7
Memory Kit
Unregistered with ECC UDIMMs
HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9
Memory Kit
HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9
Memory Kit
HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9
Memory Kit
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3
Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator .
NOTE: Kits described as LP include Low Power DIMMs. For more information on
ProLiant Energy Efficient Features, see: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/
NOTE: There is a maximum support limitation of 8 ranks per memory channel
(maximum of 2 quad rank DIMMs per channel)
500656-B21
500658-B21
500660-B21
593339-B21
516423-B21
500666-B21
500668-B21
500670-B21
500672-B21
HP Drive Cage Options HP 2U G6 4HDD CAGE Kit, FIO
HP 2U G6 8HDD CAGE Kit, FIO
HP 2U G6 12HDD CAGE Kit, FIO
HP 2U 8SFF HDD CAGE & BKPLN G6 FIO
HP 2U G6 25 SFF CAGE FIO Kit
NOTE: Selection of the 25 SFF drive cage requires an HP Smart Array P410 or
P812 controller.
HP 2U Rear 2-Bay LFF Hard Drive Kit
506926-B21
506927-B21
506928-B21
534958-B21
516011-B21
488234-B21
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 23
QuickSpecs
HP ProLiant DL180 Generation 6
Configuration Information - Factory Integrated Models
HP Power Supplies
NOTE: Many HP ProLiant Servers now offer new power options, including
Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at: www.hp.com/go/proliant-energy-efficient
HP 460W CS HE Power Supply Kit
HP 750W CS HE Power Supply Kit
HP 460W CS Platinum Power Supply Kit
HP 750W CS Platinum Power Supply Kit
CAUTION: Optional Power Supplies used for Redundancy "MUST" match the original supplied power supply. Upgrades for more power headroom, when replacing the original power supplies must match if purchased for redundancy.
Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. In ProLiant Servers that have more than one power slot (bay), same size power supplies are recommended. If non-matched power supplies are inserted you will get errors and operation will fail.
503296-B21
512327-B21
593188-B21
593831-B21
Step 3: Choose Additional Factory Integratable Options (only one from each list unless otherwise noted)
HP Storage Controller HP P410/ZM FIO Smart Array Controller
HP Smart Array P411/256 MB w/ Battery FIO
462860-B21
491193-B21
HP Smart Array P410/256 MB w/ Battery FIO
HP Smart Array P212/256 MB w/ Battery FIO
491195-B21
491191-B21
Step 4: Choose Additional Options for Factory Integration
NOTE: For additional options, please refer to the "Core Options" and "Additional Options" sections below.
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 24
QuickSpecs
Core Options
HP ProLiant DL180 Generation 6
NOTE: Some options may not be available for factory integration. Please contact an HP sales representative for additional information.
HP Unique Options
HP DL180G6 Redundant Fan Kit
HP DL180G6 Rear DVD Cage Kit
NOTE: The x16 low profile slot is not available when this option is configured.
516009-B21
515826-B21
516006-B21
536769-B21
HP Dedicated Management Port Kit
HP Internal USB Cable G6 Kit
NOTE: This option required to connect a USB device internally.
HP DL180 G6 3PCI-E x8, Full Height Kit
NOTE: This option provides two x8 full-length/full-height slots as well as an additional x8 (x4 electrically) slot. This allows the DL180G6 to have a maximum of four (4) slots.
HP PCI-X Full Riser DL180 G6 Kit
NOTE: This option kit replaces the three internal expansion slots listed in step 1 base configuration.
NOTE: Optional PCI-X option kit includes: Slot 1: full-length/full-height PCI-X
100; Slot 2: Full length/Full-height PCI-X 100. PCI-X slots are 64 bits; 133 MHz capable if only one PCI-X card is installed in the server.
577668-B21
488230-B21
HP 2U G6 8HDD LFF DL18X KIT
NOTE: Upgrading to 8 Hot Plug SATA/SAS hard drives requires the addition of a storage controller (Smart Array P410/256MB recommended), two Internal
ATA/SAS cables, (mini-SAS cable (496013-B21).
HP DL180G6 Rear 2LFF Kit
NOTE: Supports 12 hard drive server models only. Hard Drives not included.
NOTE: This option replaces the 2 Full Length, Full Height x8 PCIe slots.
HP KIT 2PCI-E x8, FH, DL180G6
NOTE: This option provides 2 Full Length, Full Height x8 PCIe slots.
HP KIT PCI-E x16, DL180G6
NOTE: This option replaces the 2 Full Length, Full Height x8 PCIe slots.
506924-B21
488234-B21
497145-B21
497143-B21
HP Processor Six-Core Processors
Intel® Xeon® Processor X5670 (2.93 GHz, 12MB L3 Cache, 95W, DDR3-1333,
HT, Turbo 2/2/2/2/3/3)
Intel® Xeon® Processor X5660 (2.80 GHz, 12MB L3 Cache, 95W, DDR3-1333,
HT, Turbo 2/2/2/2/3/3)
Intel® Xeon® Processor X5650 (2.66 GHz, 12MB L3 Cache, 95W, DDR3-1333,
HT, Turbo 2/2/2/2/3/3)
Intel® Xeon® Processor L5640 (2.26GHz, 12MB L3 Cache, 60W, DDR3-1333,
HT, Turbo 2/2/3/3/4/4)
Quad-Core Processors
Intel® Xeon® Processor E5640 (2.66 GHz, 12MB L3 Cache, 80W, DDR3-1066,
HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5630 (2.53 GHz, 12MB L3 Cache, 80W, DDR3-1066,
HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5620 (2.40 GHz, 12MB L3 Cache, 80W, DDR3-1066,
HT, Turbo 1/1/2/2)
590619-B21
590617-B21
590615-B21
590607-B21
590613-B21
590611-B21
590609-B21
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 25
QuickSpecs
Core Options
HP ProLiant DL180 Generation 6
Intel® Xeon® Processor L5630 (2.13 GHz, 12ML L3 Cache, 40W, DDR3-1066,
HT, Turbo 1/1/2/2/)
Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066,
HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066,
HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066,
HT, Turbo 1/1/2/2)
Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800)
Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)
Two-Core Processors
Intel® Xeon® Processor E5503 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)
NOTE: HT indicates that the processor model supports Intel® Hyper-Threading
Technology.
NOTE: Turbo indicates the maximum potential frequency increment when using
Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5000 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High
Performance/Wattage; "E" denotes Enterprise Performance/Wattage
(Mainstream); and "L" denotes Lower Wattage.
590605-B21
508344-B21
508343-B21
508342-B21
573909-B21
508341-B21
594118-B21
HP Memory Registered RDIMMs
HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9
Memory Kit
HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9
Memory Kit
HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low
Power Memory Kit
HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9
Memory Kit
HP 8GB (1x8GB) Dual Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7
Memory Kit
HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7
Memory Kit
HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9
Low Power Memory Kit
HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9
Low Power Memory Kit
HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9
Memory Kit
Unregistered with ECC UDIMMs
HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9
Memory Kit
HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9
Memory Kit
500656-B21
500658-B21
500660-B21
593339-B21
516423-B21
500666-B21
604504-B21
604506-B21
500662-B21
500668-B21
500670-B21
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 26
QuickSpecs
Core Options
HP ProLiant DL180 Generation 6
HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9
Memory Kit
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3
Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator
NOTE: Kits described as LP include Low Power DIMMs. For more information on
ProLiant Energy Efficient Features, see: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/
500672-B21
HP Optical Drives
HP Hard Drives
HP Slim SATA DVD-ROM Optical Drive
HP Slim SATA DVDRW Optical Drive
NOTE: Optical drives can be installed in front, on 4 & 8 bay hard drive models.
NOTE: Optical drives can be installed in 12 and 25 drive model with the addition of rear option kit (P/N 515826-B21).
481041-B21
481043-B21
NOTE: The components of a storage subsystem (e.g. the drive, the
HBA/controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.
SAS Hot Plug SFF (2.5-inch) Enterprise (ENT) Drives
HP 300GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty
Hard Drive
HP 146GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty
Hard Drive
HP 146GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty
Hard Drive
HP 72GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty
Hard Drive
SAS Hot Plug LFF (3.5-inch) Enterprise (ENT) Drives
NOTE: 3G Hard Drives will operate at up to 3.0 Gb/s in 4 drive models that use the embedded controller.
HP 600GB 6G SAS 15K rpm LFF (3.5-inch) Dual Port Enterprise 3yr Warranty
Hard Drive
HP 450GB 6G SAS 15K rpm LFF (3.5-inch) Dual Port Enterprise 3yr Warranty
Hard Drive
HP 300GB 6G SAS 15K rpm LFF (3.5-inch) Dual Port Enterprise 3yr Warranty
Hard Drive
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.html
(Worldwide)
NOTE: If selecting more than 4 hard drives or if using SAS hard drives, a Smart
Array controller and two SAS/SATA cables (P/N 464830-B21) are required.
SAS Hot Plug SFF (2.5-inch) Midline (MDL) Drives
HP 500GB 6G SAS 7.2K rpm SFF (2.5-inch) Dual Port Midline 1yr Warranty
Hard Drive
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010
507127-B21
512547-B21
507125-B21
512545-B21
516828-B21
516816-B21
516814-B21
507610-B21
Page 27
QuickSpecs
Core Options
HP ProLiant DL180 Generation 6
SAS Hot Plug LFF (3.5-inch) Midline (MDL) Drives
NOTE: 3G Hard Drives will operate at up to 3.0 Gb/s in 4 drive models that use the embedded controller.
HP 2TB 6G SAS 7.2K rpm LFF (3.5-inch) Dual Port Midline 1yr Warranty Hard
Drive
HP 1TB 6G SAS 7.2K rpm LFF (3.5-inch) Dual Port Midline 1yr Warranty Hard
Drive
SATA Hot Plug SFF (2.5-inch) Midline (MDL) Drives
HP 500GB 3G SATA 7.2K rpm SFF (2.5-inch) Midline 1yr Warranty Hard Drive
HP 160GB 3G SATA 7.2K rpm SFF (2.5-inch) Midline 1yr Warranty Hard Drive
SATA Hot Plug LFF (3.5-inch) Midline (MDL) Drives
HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive
HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive
HP 500GB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive
SATA Hot Plug LFF (3.5-inch) Entry (ETY) Drives
HP 250GB 3G SATA 7.2K rpm LFF (3.5-inch) Entry 1yr Warranty Hard Drive
HP 160GB 3G SATA 7.2K rpm LFF (3.5-inch) Entry 1yr Warranty Hard Drive
NOTE: Please see the QuickSpecs for Technical Specifications and additional specifications: http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html
(Worldwide)
SATA Hot Plug Midline (MDL) Solid State Drives
HP 60GB 3G SATA SFF (2.5-inch) Midline 1yr Warranty Solid State Drive
HP 120GB 3G SATA SFF (2.5-inch) Midline 1yr Warranty Solid State Drive
SATA Hot Plug 3.5" Midline (MDL) Solid State Drives
HP 60GB 3G SATA LFF (3.5-inch) Midline 1yr Warranty Solid State Drive
HP 120GB 3G SATA LFF (3.5-inch) Midline 1yr Warranty Solid State Drive
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13415_div/13415_div.html
(Worldwide)
507616-B21
507614-B21
507750-B21
530888-B21
507632-B21
454146-B21
458928-B21
571230-B21
458945-B21
572071-B21
572073-B21
570761-B21
570763-B21
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 28
QuickSpecs
Core Options
HP Networking
HP ProLiant DL180 Generation 6
Gigabit Ethernet Adapters
HP NC112T PCIe Gigabit Server Adapter
HP NC360T PCI Express Dual Port Gigabit Server Adapter
HP NC364T PCI Express Quad Port Gigabit Server Adapter
NOTE: Does not support Windows 2000.
HP NC365T 4-port Ethernet Server Adapter
HP NC373F PCI Express Multifunction Gigabit Server Adapter
HP NC373T PCI Express Multifunction Gigabit Server Adapter
HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter
10 Gigabit Ethernet Adapters
NOTE: No more than two10GbE I/O devices are supported in a single ProLiant server.
NOTE: A minimum of two Gigabytes (2 GB) of server memory is required per each adapter.
NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately.
HP NC522SFP Dual Port 10GbE Server Adapter
HP NC550SFP Dual Port 10GbE Server Adapter
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs .
503746-B21
412648-B21
435508-B21
593722-B21
394793-B21
394791-B21
458492-B21
468332-B21
581201-B21
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 29
QuickSpecs
Additional Options
HP ProLiant DL180 Generation 6
HP Entry-Level Server
Management
HP LO100i Advanced Pack, No Media 1-Server License including 1 year of 24x7
Technical Support and Updates
NOTE: For additional License Kits please see the Lights-Out 100i QuickSpecs at: www.hp.com/go/lo100 .
530521-B21
HP Insight Software HP Insight Control for Linux
HP Insight Control for Linux, 1-server license, including one year of 24x7
Technical Support and Updates, Electronic
NOTE: This part number can be purchased as a single license or as multiple licenses with a single activation key. Customer will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service.
NOTE: Electronic software is available in all countries except China and Japan.
For China and Japan should order the physical equivalent.
HP Insight Control for Linux, No Media, 1-Server license, including one year of
24x7 Technical Support and Updates
HP Insight Control for Linux, Media pack (DVD) - No licenses included
NOTE: This optional Media pack DVD contains the ISO image for HP Insight
Control for Linux, HP Systems Insight Manager, HP Insight Control power management, HP Insight Control virtual machine management, and an integrated installer. Servers must be acquired separately.
NOTE: This Media pack is optional because the latest ISO image and latest updates may be downloaded at no cost from: http://www.hp.com/go/ic-linux (click on Download button).
NOTE: Licenses ship without media. The Media Kit for Insight Control for Linux can be ordered separately, or can be downloaded at: http://www.hp.com/go/iclinux (click on Download button).
NOTE: Electronic software is available in all countries except China and Japan.
For China and Japan should order the physical equivalent.
NOTE: Customer will receive a license entitlement certificate, which must be redeemed online or via fax in order to obtain the license activation key(s).
Includes one year of 24 x 7 HP Software Technical Support Service.
NOTE: For additional License Kits, including electronic licensing options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_div/13019_div.html
HP Insight Control server deployment
HP Insight Control server deployment Electronic License including 1 year 24x7
Technical Support and Updates
HP Insight Control server deployment 1-Server License including 1 year 24x7
Technical Support and Updates
NOTE: Licenses ship without media. The Insight Control Media Kit can be ordered separately, or can be downloaded at: http://www.hp.com/go/insightupdates .
NOTE: Electronic software is available in all countries except China and Japan.
For China and Japan should order the physical equivalent.
NOTE: Customer will receive a license entitlement certificate, which must be redeemed online or via fax in order to obtain the license activation key(s).
Includes one year of 24 x 7 HP Software Technical Support Service.
NOTE: For additional license kits please see the Insight Control QuickSpecs at:
TC213AAE
TC209A
TC208A
T9082AAE
452151-B21
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 30
QuickSpecs
Additional Options
HP ProLiant DL180 Generation 6
http://h18004.www1.hp.com/products/quickspecs/12631_div/12631_div.html
600278-B21
HP I/O Accelerator
Options
HP 160GB SLC PCIe ioDrive
NOTE: A low-profile PCI bracket is included for use in low-profile slots.
NOTE: A minimum of 4 GB of system memory is required per card
HP 320GB MLC PCIe ioDrive
NOTE: A low-profile PCI bracket is included for use in low-profile slots.
NOTE: A minimum of 8 GB of system memory is required per card
HP 320GB SLC PCIe ioDrive Duo
NOTE: A minimum of 8 GB of system memory is required per card
HP 640GB MLC PCIe ioDrive Duo
NOTE: A minimum of 16 GB of system memory is required per card
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13587_div/13587_div.html
(Worldwide)
HP Graphics Options
HP Graphic Card Power Adapter Kit
NOTE: The kit is applicable for 4LFF,8LFF and 8SFF cages . The Graphic
Power Adapter Kit can support up to 150 Watts.
HP Security - TPM
HP Trusted Platform Module Option Kit
HP Storage Controllers SAS Controllers
HP Smart Array P212 Controller
HP P212/Zero Memory Smart Array Controller
HP P212/256MB Smart Array Controller
HP Smart Array P410 Controller
HP Smart Array P410/256MB Controller
HP Smart Array P410/512MB BBWC Controller
HP Smart Array P410/1G with FBWC
HP Smart Array P410/512MB with FBWC
HP Smart Array P411 Controller
HP Smart Array P411/256MB Controller
HP Smart Array P411/512MB BBWC
HP Smart Array P411/1G Flash Backed Write Cache
HP Smart Array P411/512MB Flash Backed Write Cache
Smart Array P800 Controller
HP Smart Array P800/512 BBWC Controller
HP Smart Array P812 Controller
HP Smart Array P812/1G Flash Backed Cache Controller
Optional Upgrades
HP Int SAS/SATA Multi-Lane Cable Kit
600279-B21
600281-B21
600282-B21
533955-B21
488069-B21
462828-B21
462834-B21
462862-B21
462864-B21
572532-B21
578230-B21
462830-B21
462832-B21
572531-B21
578229-B21
381513-B21
487204-B21
464830-B21
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 31
QuickSpecs
Additional Options
HP ProLiant DL180 Generation 6
HP Mini SAS to Mini SAS 28in Cable Assy
NOTE: Supports internal drives on the DL180 G6 with the Smart Array P800
Controller.
1G Flash Backed Write Cache
256 MB Cache Module
NOTE: Supported on HP Smart Array P212 Controller only.
512MB Flash Backed Write Cache
512MB BBWC
NOTE: Supported on HP Smart Array P410 Controller and HP Smart Array P411
Controller only.
Battery Kit upgrade
NOTE: To enable BBWC on the 256MB cache.
NOTE: Supported on HP Smart Array P212 Controller, HP Smart Array P410
Controller, and HP Smart Array P411 Controller only.
HP 8484 to Mini SAS 33in Cable Assembly
NOTE: Cable for use connecting the Smart Array P800 Controller to internal hard disk drives on select HP ProLiant G6 Servers.
HP Smart Array Hot Plug Advanced Pack for B110i No Media 1-Server license including 1yr 24x7 Technical Support
HP Smart Array Advanced Pack No Media 1-Server license including 1yr 24x7
Technical Support
NOTE: This part number can be used to purchase a single license or to order multiple licenses with a single activation key. Customers will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s).
Include one year of 24x7 HP Software Technical Support Services.
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13203_div/13203_div.html
(Smart Array P212 Controller) http://h18000.www1.hp.com/products/quickspecs/13201_div/13201_div.html
(Smart Array P410 Controller) http://h18000.www1.hp.com/products/quickspecs/13202_div/13202_div.html
(Smart Array P411 Controller)
SAS HBA
HP SC08Ge Host Bus Adapter
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13082_div/13082_div.html
(SC08Ge HBA)
HP SC08e 6Gb 2-ports Ext PCIe SAS HBA
NOTE: This is a 2 x4 External Port HBA.
NOTE: This is only approved for the HP Storage Works P2000 G3 SAS Modular
Smart Array.
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13651_div/13651_div.html
SCSI HBA
HP SC11Xe Host Bus Adapter
NOTE: Recommended HBA for SCSI tape drive connect.
496013-B21
534562-B21
462968-B21
534916-B21
462967-B21
462969-B21
591734-B21
TC421A
516471-B21
488765-B21
614988-B21
412911-B21
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 32
QuickSpecs
Additional Options
HP ProLiant DL180 Generation 6
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12566_div/12566_div.html
(SCSI HBA)
HP InfiniBand Options QLogic IB 4X QDR PCI-e G2 Dual-port HC
HP IB 4X QDR CX-2 PCI-e G2 Dual Port HCA
HP IB 4X DDR CX-2 PCI-e G2 Dual Port HCA
NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13078_div/13078_div.html
HP Backup & Recovery
Software
Data Protector Express
HP Data Protector Express 4.0 SP1 Backup Server
HP Data Protector Express 4.0 SP1 for Microsoft Small Business Server
HP Data Protector Express Backup Server 4.0 SP1 Upgrade from Data Protector
Express Single Server Edition
NOTE: Only one of these Data Protector Express base products is required. To see available options: http://www.hp.com/go/dataprotectorexpress
HP Tape Backup
NOTE: For the complete range of StorageWorks tape drives, autoloaders, libraries and media see: http://www.hp.com/go/tape . For hardware and software compatibility of HP StorageWorks tape backup products see: http://www.hp.com/go/connect .
HP StorageWorks DAT 160 SAS Internal Tape Drive
NOTE: For installation into 1U SAS Rack-Mount Kit (AE459B) or 3U SAS Rack-
Mount Kit (AG576B). No peripheral bay available for installation into the server.
Connection using the HP SC44Ge SAS Host Bus Adapter (416096-B21) recommended.
HP StorageWorks 1U USB Rack-Mount Kit with one DAT 320 USB Tape Drive
HP StorageWorks DAT 320 SAS Internal Tape Drive
NOTE: For installation into 1U SAS Rack-Mount Kit (AE459B) or 3U SAS Rack-
Mount Kit (AG576B). No peripheral bay available for installation into the server.
Connection using the HP SC44Ge SAS Host Bus Adapter (416096-B21) recommended.
HP StorageWorks LTO-2 Ultrium 448 SAS Internal Tape Drive
NOTE: For installation into 1U SAS Rack-Mount Kit (AE459B) or 3U SAS Rack-
Mount Kit (AG576B). No peripheral bay available for installation into the server.
Connection using the HP SC44Ge SAS Host Bus Adapter (416096-B21) recommended.
HP StorageWorks LTO-3 Ultrium 920 SAS Internal Tape Drive
NOTE: For installation into 1U SAS Rack-Mount Kit (AE459B) or 3U SAS Rack-
Mount Kit (AG576B). No peripheral bay available for installation into the server.
Connection using the HP SC44Ge SAS Host Bus Adapter (416096-B21) recommended.
HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Tape Autoloader
NOTE: Requires HP 1U Tape Autoloader Rack-Mount Kit (AH166A) for rack installation. Connection using the HP SC44Ge SAS Host Bus Adapter (416096-
B21) recommended.
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010
583211-B21
592520-B21
592521-B21
BB117BA
BB118BA
BB117BT
Q1587A
AP835A
AJ830A
DW085A
EH847A
AH558A
Page 33
QuickSpecs
Additional Options
HP ProLiant DL180 Generation 6
HP StorageWorks MSL2024 Tape Library with one LTO-3 Ultrium 920 SAS
Drive
NOTE: Connection using the HP SC44Ge SAS Host Bus Adapter (416096-B21) recommended.
AH559A
HP Disk Backup
NOTE: For the complete range of StorageWorks D2D Backup Systems see: http://www.hp.com/go/d2d . For the complete range of StorageWorks RDX drives and media see: http://www.hp.com/go/rdx . For hardware and software compatibility of HP StorageWorks disk backup products see: http://www.hp.com/go/connect .
HP StorageWorks D2D Backup Systems with Backup Data Deduplication
HP StorageWorks D2D2502i Backup System
NOTE: 1.5TB of usable network disk backup capacity. Network connected appliance with connectivity using the iSCSI protocol. If the server requires a hardware iSCSI initiator, the QLogic QLA4050 Host Bus Adapter is recommended.
HP StorageWorks D2D2504i Backup System
NOTE: 3.0TB of usable network disk backup capacity. Network connected appliance with connectivity using the iSCSI protocol. If the server requires a hardware iSCSI initiator, the QLogic QLA4050 Host Bus Adapter is recommended.
USB Removable Media RDX Disk Backup Systems
HP StorageWorks RDX320 Internal Removable Disk Backup System
NOTE: For installation into 1U USB Rack-Mount Kit (A8007A). No peripheral bay available for drive installation into the server. 320GB of disk capacity per data cartridge.
HP StorageWorks RDX500 Internal Removable Disk Backup System
NOTE: For installation into 1U USB Rack-Mount Kit (A8007A). No peripheral bay available for drive installation into the server. 500GB of disk capacity per data cartridge.
HP StorageWorks RDX750 Internal Removable Disk Backup System
NOTE: For installation into 1U USB Rack-Mount Kit (A8007A). No peripheral bay available for drive installation into the server. 750GB of disk capacity per data cartridge.
EJ001A
EJ002A
AJ767A
AJ934A
AW577A
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 34
QuickSpecs
HP ProLiant DL180 Generation 6
Additional Options
HP StorageWorks
Options
StorageWorks Fibre Channel HBA
NOTE: The following is a list of all Fibre Channel Host Bus Adapters for
Windows and Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html
.
Brocade Fibre Channel HBAs
HP 81B PCIe 8Gb FC Single Port HBA
HP 82B PCIe 8Gb FC Dual Port HBA
HP 41B PCIe 4Gb FC Single Port HBA
HP 42B PCIe 4Gb FC Dual Port HBA
Emulex Fibre Channel HBAs
HP StorageWorks 81E 8Gb SP PCI-e FC HBA
HP 82E 8Gb Dual-port PCI-e FC HBA
HP StorageWorks FC2142SR 4Gb PCI-e HBA
HP StorageWorks FC2242SR Dual Channel 4Gb PCI-e FC HBA
QLogic Fibre Channel HBAs
HP StorageWorks 81Q PCI-e FC HBA
HP 82Q 8Gb Dual Port PCI-e FC HBA
HP StorageWorks FC1142SR 4Gb PCI-e HBA
HP StorageWorks FC1242SR Dual Channel 4 Gb PCI-e HBA
StorageWorks SCSI HBA
HP U320e SCSI Host Bus Adapter
NOTE: Recommended for MSL SCSI Tape Library connect.
StorageWorks Converged Network Adapter
HP CN1000E 2P Converged Network Adapter
AP769A
AP770A
AP767A
AP768A
AJ762A
AJ763A
A8002A
A8003A
AK344A
AJ764A
AE311A
AE312A
AH627A
AW520A
HP Disk Storage
Systems
MSA SAN Storage Arrays
HP StorageWorks MSA60 Array
NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12627_div/12627_div.html
HP StorageWorks MSA70 Array
NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12652_div/12652_div.html
418408-B21
418800-B21
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 35
QuickSpecs
HP ProLiant DL180 Generation 6
Additional Options
HP Uninterruptible
Power Systems
HP Rack-mountable UPS
HP R1500 G2 UPS
HP R1.5 VA 1U UPS NA
HP R1.5 VA 1U UPS INTL
HP, R1.5kVA UPS, 1U, JPN/TW
HP R/T3000 UPS
HP R/T3000 UPS, High voltage, NA/JPN
HP R/T3000 UPS, High voltage, detachable inlet cord INTL
HP Rack-Mountable R5500 UPS
HP R5500 3U Intl UPS
HP R5500 3U NA/JP UPS
NOTE: For additional information on all HP Uninterruptible Power Systems and accessories please go to: www.hp.com/products/ups (Worldwide)
NOTE: For additional information on sizing your server, please reference: http://www.upssizer.com
AF419A
AF418A
AF421A
AF453A
AF454A
AF416A
AF426A
HP Power Distribution
Units
Monitored PDUs
HP Monitored Power Distribution Unit: Full Rack Version
HP 8.6 kVA S1324 Monitored PDU- single input, 3Ø, 24A (NA/JPN)
HP 8.3 S1140 Monitored PDU- single input, 1Ø, 40A (NA/JPN)
HP 11 kVA S1316 Monitored PDU- single input, 3Ø, 16A (INTL)
HP 7.3 kVA S1132 Monitored PDU- single input, 1Ø, 32A (INTL)
HP Monitored Power Distribution Unit: Half Rack Version
HP 4.9 kVA S124 Monitored PDU- single input, 1Ø, 24A (NA/JPN)
HP 7.3 kVA S132 Monitored PDU- single input, 1Ø, 32A (INTL)
Modular PDUs 1U/0U (Up to 28 outlets)
4.9 kVA Modular PDU, 24A, NA/JPN
8.3 kVA Modular PDU, 40A, NA/JPN
3.6 kVA Modular PDU, 16A, INTL
7.3 kVA Modular PDU, 32A, INTL
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12118_div/12118_div.html
(Worldwide)
AF504A
AF506A
AF508A
AF510A
AF914A
AF915A
252663-D72
252663-D73
252663-B24
252663-B31
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 36
QuickSpecs
HP ProLiant DL180 Generation 6
Additional Options
HP Rack Series
HP Rack 10000 G2 Series (Carbon/Graphite Metallic)
HP Universal Rack 10642 G2 Pallet ALL
HP Universal Rack 10642 G2 Shock ALL
NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed.
NOTE: Please see the Rack 10000 G2 QuickSpecs for Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html
(Worldwide)
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower .
AF001A
AF002A
HP Rack Options
HP USB and SD
Options
HP KVM Switch Options
HP 0x2x8 KVM Server Console G2 Switch
HP 0x2x16 KVM Server Console G2 Switch
NOTE: Cat5e cables are required to connect Interface Adapters to Console
Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm .
HP Serial Console Server Options
0x2x16 KVM Server Console G2 Switch with Virtual Media and CAC
0x2x32 KVM Server Console G2 Switch with Virtual Media and CAC
1x1Ex8 KVM IP Console Switch G2 with Virtual Media and CAC
2x1Ex16 KVM IP Console Switch G2 with Virtual Media and CAC
4x1Ex32 KVM IP Console Switch G2 with Virtual Media and CAC
NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console
Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm .
NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm .
Rack Kits
HP Rack Cable Management Velcro Clips
AF616A
AF617A
AF618A
AF619A
AF620A
AF621A
AF622A
379820-B21
HP External USB CD/DVD R/RW Optical Drive
HP USB-PS/2 Mouse
HP USB 04 Standard Keyboard
HP 2GB USB Flash Media Drive Key Kit
NOTE: HP qualified blank USB key for use with HP ProLiant servers that support the VMware virtualization environment and other HP value-add software like
SmartStart. HP recommends this industry standard USB flash device for use with VMware ESXi. USB device must be installed in the internal slot of the
ProLiant server for use with VMware ESXi. Refer to HP VMware Getting Started
Guide for installation instructions.
FS943AA#ABA
DC369A
DT528A#ABA
608447-B21
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 37
QuickSpecs
HP ProLiant DL180 Generation 6
Additional Options
HP Care Pack Services Hardware Services 4-Hour On-site Service
13-Hour x 5-Day Coverage, 3 Years, Electronic
24-Hour x 7-Day Coverage, 3 Years, Electronic
Hardware Services Next Business Day On-Site Service
9-Hour x 5-Day Coverage, 3 Years, Electronic
Hardware Services 6-Hour Call to Repair On-Site Service
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
Hardware Installation, Electronic
NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack .
UH271E
UH272E
UH270E
UH273E
UH301E
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 38
QuickSpecs
Memory
HP ProLiant DL180 Generation 6
NOTE: Memory configurations listed do not apply to "Factory Integrated Models".
HP ProLiant DL180 G6
Standard Memory (depending on model)
4GB (1 x 4GB) PC3-10600R-9 Registered memory, with Advanced ECC Capabilities Memory installed.
8GB (2 x 4GB) PC3-10600R-9 Registered memory, with Advanced ECC Capabilities Memory installed.
16GB (4 x 4GB) PC3-10600R-9 Registered memory, with Advanced ECC Capabilities Memory installed.
Maximum Memory
Up to 192GB memory is available with the optional installation of PC3-8500R Registered DIMM memory kits.
NOTE: Charts do not represent all possible memory configurations.
DDR3 memory population guidelines
For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator
Some DIMM installation guidelines are summarized below:
For servers with twelve (12) memory slots
There are three (3) channels per processor; six (6) channels per server
There are two (2) DIMM slots for each memory channel; twelve (12) total slots
Memory channel 1 consists of the two (2) DIMMs that are closest to the processor
Memory channel 3 consists of the two (2) DIMMs that are furthest from the processor
DIMM slots that are white should be populated first
Do not mix Unbuffered memory (UDIMMs) with Registered memory (RDIMMs)
Do not install DIMMs if the corresponding processor is not installed
If only one processor is installed in a 2CPU system, only half of the DIMM slots are available
To maximize performance, balance the total memory capacity between all installed processors
It is not required, but it is recommended to load the channels similarly if possible
If any Quad rank DIMMs are installed, all channels are limited to only 2 DIMMs per channel.
You can only install two quad-rank DIMMs per channel
You can install two UDIMMs per channel; if available, the third slot in the channel must remain empty
Populate DIMMs from heaviest load (quad-rank) to lightest load (single-rank) within a channel
Heaviest load (DIMM with most ranks) within a channel goes furthest from the chipset
If mixing DIMM voltage is a requirement, please note that the DIMMs will run at 1.5V since all 1.35V are capable of supporting 1.5V operations
Low Voltage DIMMs can only be used with Intel Xeon 5600 series processors.
For memory mirroring mode, channel 3 must be unpopulated. Channels 1 and 2 are populated identically
For lock-step mode, channel 3 must be unpopulated. DIMMs in channels 1 and 2 will be installed in pairs. The paired slots will be 1,4; 2,5; 3;6 on a 3DPC system or 1,4; 2,5; on a 2DPC system
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 39
QuickSpecs
HP ProLiant DL180 Generation 6
Memory
DIMM Type ->
Registered DIMMS (RDIMMs)
DIMM Rank ->
DIMM Capacity ->
DIMM Native Speed
(MHz) ->
Voltage
12 slot servers
Single
Rank
(1R)
4GB
1333
LV/Reg
2GB
1333
Reg
Dual Rank (2R)
4GB
1333
Reg
8GB
1066
Reg
SLOTS THAT CAN BE POPULATED
12 12 12 12
8GB
1333
LV/Reg
12
Quad Rank (4R)
4GB
1066
Reg
12
16GB
1066
Reg
12
Unbuffered with ECC DIMMs
Single
Rank
(1R)
1GB
1333
Reg
12
(UDIMMs)
12 slot servers
MAXIMUM CAPACITY (GB)
48 24 48 96 96 48 192 12
POPULATED DIMM SPEED (MHz)
1 DIMM Per
Channel
2 DIMM Per
Channel
1333
1333 *
1333
1333 *
1333
1333 *
1066
1066
1333
1333 *
1066
800
1066
800
1333
1066
* Supported with BIOS update via ROM Based Setup Utility (RBSU). UDIMM support is on 12-slot server.
Dual Rank (2R)
2GB
1333
Reg
12
24
1333
1066
4GB
1333
Reg
12
48
1333
1066
NOTES:
PC3-10600 DIMMs have a maximum speed of 1333MHz. PC3-8500 DIMMs have a maximum speed of 1066MHz
Mixing DIMM speeds is allowed, but the system processor speed rules always override the DIMM capabilities.
If you do mix DIMM speeds, the memory bus will default to the minimum clock rate of all DIMMs in the system - even if the slower DIMM is on the other processor.
If you install 1x 1066MHz DIMM in channel 1 and 1x 1333MHz DIMM in channel 2, the maximum speed will be
1066MHz.
If you install 1x 1066MHz DIMM in channel 1 and 5x 1333MHz DIMMs with 1 DIMM Per Channel (DPC) in each of the other channels, the maximum speed will be 1066MHz.
If you install 3DPC in one channel (if applicable) and 1DPC in all other channels, you run at 800MHz.
Maximum memory speed will also depend on the processor installed.
References to the above MHz speeds are for the various speeds of DDR3 DIMMs; 1333 refers to DDR3-1333, etc.
DIMM slot and configuration diagrams
Basic memory slot & population diagram
Population order; start with "A" first, "B" second, "C" third, etc.
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 40
QuickSpecs
HP ProLiant DL180 Generation 6
Memory
Chnl 1
Chnl 2
Chnl 3 5
3
4 slot #
1
2
6
CPU1
12 DIMM SLOTS (6 per CPU node)
CPU2
population order
D
A slot #
1
2 population order
D Chnl 1
A
Chnl 2
F
E
B
C
5
3
4
6
F
E
B
C
Chnl 3
Standard memory configuration (1 CPU model)
Chnl 1
Chnl 2
Chnl 3
6GB, consisting of three (3) 2GB dual-rank PC3-10600 RDIMMs
5
3
4 slot #
1
2
6
CPU1
population order
D: empty
A: 2GB DIMM
E: empty
B: 2GB DIMM
F: empty
C: 2GB DIMM
5
3
4 slot #
1
2
6
Standard memory plus optional memory (1 CPU model)
CPU2
E: empty
B: empty
F: empty
C: empty population order
D: empty Chnl 1
A: empty
Chnl 2
Chnl 3
Chnl 1
Chnl 2
Chnl 3
30GB, consisting of three (3) 2GB RDIMMs plus three (3) 8GB RDIMMs
3x 2GB dual-rank PC3-10600 RDIMMs
3x 8GB dual-rank PC3-8500 RDIMMs
5
3
4 slot #
1
2
6
CPU1
population order
D: 8GB DIMM
A: 2GB DIMM
E: 8GB DIMM
B: 2GB DIMM
F: 8GB DIMM
C: 2GB DIMM
5
3
4 slot #
1
2
6
Standard memory replaced with optional memory (1 CPU model)
RDIMM maximum configuration
CPU2
population order
D: empty Chnl 1
A: empty
Chnl 2 E: empty
B: empty
F: empty Chnl 3
C: empty
96GB, consisting of six (6) 16GB quad-rank PC3-8500 RDIMMs
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 41
QuickSpecs
Memory
Chnl 1
Chnl 2
Chnl 3 5
6
4 slot #
3
1
2
CPU1
population order
D: 16GB DIMM
A: 16GB DIMM
E: 16GB DIMM
B: 16GB DIMM
I: 16GB DIMM
C: 16GB DIMM
UDIMM maximum configuration (1 CPU model)
Chnl 1
Chnl 2
Chnl 3
24GB, consisting of six (6) 4GB dual-rank PC3-10600 UDIMMs
5
6
4 slot #
3
1
2
CPU1
population order
D: 4GB DIMM
A: 4GB DIMM
E: 4GB DIMM
B: 4GB DIMM
F: 4GB DIMM
C: 4GB DIMM
5
6
4 slot #
3
1
2
Standard memory replaced with optional memory (2 CPU model)
RDIMM maximum configuration
Chnl 1
Chnl 2
Chnl 3
192GB, consisting of twelve (12) 16GB quad-rank PC3-8500 RDIMMs
5
6
4 slot #
3
1
2
CPU1
population order
D: 16GB DIMM
A: 16GB DIMM
E: 16GB DIMM
B: 16GB DIMM
F: 16GB DIMM
C: 16GB DIMM
5
6
4 slot #
3
1
2
UDIMM maximum configuration (2 CPU model)
48GB, consisting of twelve (12) 4GB dual-rank PC3-10600 UDIMMs
5
6
4 slot #
3
1
2
HP ProLiant DL180 Generation 6
CPU2
population order
Chnl 1 D: empty
A: empty
E: empty Chnl 2
B: empty
I: empty
C: empty
Chnl 3
CPU2
population order
Chnl 1 D: empty
A: empty
E: empty Chnl 2
B: empty
F: empty
C: empty
Chnl 3
CPU2
population order
D: 16GB DIMM Chnl 1
A: 16GB DIMM
E: 16GB DIMM Chnl 2
B: 16GB DIMM
F: 16GB DIMM Chnl 3
C: 16GB DIMM
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 42
QuickSpecs
HP ProLiant DL180 Generation 6
Memory
Chnl 1
Chnl 2
Chnl 3 5
6
4 slot #
3
1
2
CPU1
population order
D: 4GB DIMM
A: 4GB DIMM
E: 4GB DIMM
B: 4GB DIMM
F: 4GB DIMM
C: 4GB DIMM
5
6
4 slot #
3
1
2
NOTE: Capacity references are rounded to the common Gigabyte values.
1GB = 1024MB
2GB = 2048MB
4GB = 4096MB
8GB = 8192MB
16GB = 16384MB
CPU2
population order
D: 4GB DIMM Chnl 1
A: 4GB DIMM
E: 4GB DIMM Chnl 2
B: 4GB DIMM
F: 4GB DIMM Chnl 3
C: 4GB DIMM
For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator
HP Memory Registered RDIMMs
HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9
Memory Kit
HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9
Memory Kit
HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9
Memory Kit
HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low
Power Memory Kit
HP 8GB (1x8GB) Dual Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7
Memory Kit
HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7
Memory Kit
HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9
Low Power Memory Kit
HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9
Low Power Memory Kit
HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9
Memory Kit
Unregistered with ECC UDIMMs
HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9
Memory Kit
HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9
Memory Kit
HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9
Memory Kit
500656-B21
500658-B21
593339-B21
500660-B21
516423-B21
500666-B21
604504-B21
604506-B21
500662-B21
500668-B21
500670-B21
500672-B21
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 43
QuickSpecs
Memory
HP ProLiant DL180 Generation 6
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3
Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator .
NOTE: Kits described as LP include Low Power DIMMs. For more information on
ProLiant Energy Efficient Features, see: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 44
QuickSpecs
Storage
8 Drive Cage with DVD-Drive bay
12 Drive Cage
HP ProLiant DL180 Generation 6
1-8 Eight 3.5" Hot Plug SAS/SATA Hard Drive Bays
9 DVD-ROM, DVD RW
1-12 Twelve 3.5" Hot Plug SAS/SATA Hard Drive Bays
13-14
Not
Shown
Two Rear 3.5" Hot Plus SAS/SATA Hard Drive Bays
Drive Support
Removable Media
DVD-ROM
DVD RW
Quantity
Supported
Up to 1
Up to 1
Position
Supported Controller
9 Integrated IDE (ATAPI) (optional)
9 Integrated IDE (ATAPI) (optional)
Hard Drives
NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.
SATA Hot Plug SFF (2.5-inch) Midline (MDL) Drives
500GB 3G SATA 7.2K
160GB 3G SATA 7.2K
Quantity
Supported
Up to 8 with 8 drive cage
Up to 25 with 25 drive cage
Position
Supported
1-8
1-25
Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
NOTE: Smart Array P212 Controllers recommended.
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 45
QuickSpecs
HP ProLiant DL180 Generation 6
Storage
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
HP Smart Array Hot Plug Advance Pack for B110i
SATA Hot Plug LFF (3.5-inch) Midline (MDL) Drives
2TB 3G SATA 7.2K
1TB 3G SATA 7.2K
500GB 3G SATA 7.2K
Quantity
Supported
Up to 8 with 8 drive cage
Position
Supported Controller
1-8 HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
Up to 14 with 12 drive cage +
Rear Drive Cage
1-14 NOTE: Smart Array P212 Controllers recommended.
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
HP Smart Array Hot Plug Advance Pack for B110i
SATA Hot Plug LFF (3.5-inch) Entry (ETY) Drives
250GB 3G SATA 7.2K
160GB 3G SATA 7.2K
Quantity
Supported
Up to 8 with 8 drive cage
Position
Supported Controller
1-8 HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
Up to 14 with 12 drive cage +
Rear Drive Cage
1-14 HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
HP Smart Array Hot Plug Advance Pack for B110i
SATA Hot Plug Midline (MDL) Solid State Drives
60GB 3.0G SATA SSD
120GB 3.0G SATA SSD
Quantity
Supported
Up to 8 with 8 drive cage
Position
Supported Controller
1-8 HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 46
QuickSpecs
HP ProLiant DL180 Generation 6
Storage
Up to 25 with 25 drive cage
1-25
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array Hot Plug Advance Pack for B110i
SATA Hot Plug 3.5" Midline (MDL) Solid State Drives
Quantity
Supported
Position
Supported Controller
60GB 3.0G SATA SSD
120GB 3.0G SATA SSD
Up to 8 with 8 drive cage
1-8 HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array B110i Hot Plug Advance Pack for B110i
SAS Hot Plug SFF (2.5-inch) Midline (MDL) Drives
500GB 6G SAS 7.2K
Quantity
Supported
Up to 8 with 8 drive cage
Position
Supported Controller
1-8 HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
Up to 25 with 25 drive cage
1-25 HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
SAS Hot Plug LFF (3.5-inch) Midline (MDL) Drives
2TB 6G SAS 72K
1TB 6G SAS 7.2K
Quantity
Supported
Up to 8 with 8 drive cage
Position
Supported Controller
1-8 HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 47
QuickSpecs
HP ProLiant DL180 Generation 6
Storage
Up to 14 with 12 drive cage +
Rear Drive Cage
1-14
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
SAS Hot Plug SFF (2.5-inch) Enterprise (ENT) Drives
Quantity
Supported
Position
Supported Controller
300GB 6G 10K SAS
146GB 6G 15K SAS
146GB 6G 10K SAS
72GB 6G 15K SAS
Up to 8 with 8 drive cage
Up to 25 with 25 drive cage
1-8
1-25
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
SAS Hot Plug LFF (3.5-inch) Enterprise (ENT) Drives
Quantity
Supported
Position
Supported Controller
600GB 6G SAS 15K DP
450GB 6G SAS 15K DP
300GB 6G SAS 15K
Up to 8 with 8 drive cage
Up to 14 with 12 drive cage +
Rear Drive Cage
1-8
1-14
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P410/512 MB FBWC Controller
HP Smart Array P410/1G FBWC Controller
HP Smart Array P812/1G FBWC Controller
HP Smart Array P800/512 BBWC Controller
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 48
QuickSpecs
Storage
External Storage
Quantity
Supported
Up to 4 60 Modular Smart Array
70 Modular Smart Array
Up to 8
Up to 2
Up to 4
HP ProLiant DL180 Generation 6
Position
Supported Controller
External HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/256 MB Controller
HP Smart Array P800/512 BBWC Controller
External
External
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 FBWC Controller
HP Smart Array P411/512 MB FBWC Controller
HP Smart Array P411/1G FBWC Controller
HP Smart Array P812/1G Flash Backed Cache Controller
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212 Zero Memory Controller
HP Smart Array P212/256 MB Controller
External HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB FBWC Controller
HP Smart Array P411/512 MB FBWC Controller
HP Smart Array P411/1G FBWC Controller
HP Smart Array P812/1G Flash Backed Cache Controller
HP Smart Array P800/512 BBWC Controller
Tape and Disk Backup
NOTE: For the complete range of StorageWorks tape drives, autoloaders, libraries and media, including the internal fitting models, see: http://www.hp.com/go/tape . For the complete range of StorageWorks D2D Backup Systems see: http://www.hp.com/go/d2d . For the complete range of StorageWorks RDX drives and media see: http://www.hp.com/go/rdx .
For hardware and software compatibility of HP StorageWorks disk and tape backup products see: http://www.hp.com/go/connect .
Position
External
Recommended Controller
HP SC11Xe Host Bus Adapter
Part Number
412911-B21
HP StorageWorks SCSI
Tape Drives, External
LTO-1 Ultrium 232
LTO-2 Ultrium 448
LTO-3 Ultrium 920
LTO-3 Ultrium 960
LTO4 Ultrium 1760
LTO-4 Ultrium 1840
DAT 40
DAT 72
DAT 160
1U Rack-Mount Kit
3U Rack-Mount Kit
HP StorageWorks USB
Tape Drives, External
DAT 40
DAT 72
DAT 160
DAT 320
1U USB Rack-Mount Kit
External
Please check the full compatibility information at: http://www.hp.com/go/connect
USB 2.0 Port N/A
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 49
QuickSpecs
Storage
HP StorageWorks SAS
Tape Drives, External
DAT 160
DAT 320
LTO-2 Ultrium 448
LTO-3 Ultrium 920
LTO-4 Ultrium 1760
LTO-4 Ultrium 1840
LTO-5 Ultrium 3000
LTO-5 Ultrium 3280
1U Rack-Mount Kit
3U Rack-Mount Kit
HP StorageWorks SCSI
Tape Autoloaders,
External
DAT 72x10 Autoloader
1/8 G2 Autoloader
HP StorageWorks SCSI
Tape Libraries,
External
MSL2024
MSL4048
MSL8096
MSL6000
HP StorageWorks SAS
Tape Autoloaders and
Libraries, External
1/8 G2 Autoloader
MSL2024
MSL4048
MSL8096
HP StorageWorks Fibre
Channel Tape
Libraries, External
MSL2024
MSL4048
MSL8096
MSL6000
HP StorageWorks USB
RDX Removable Disk
Backup System,
External
RDX160
RDX320
RDX500
RDX750
External
External
External
External
External
External
HP Smart Array P212 SAS controller
Please check the full compatibility information at: http://www.hp.com/go/connect
HP SC11Xe Host Bus Adapter
Please check the full compatibility information at: http://www.hp.com/go/connect
HP U320e SCSI Dual Channel Controller
Please check the full compatibility information at: http://www.hp.com/go/connect
HP Smart Array P212 SAS controller
Please check the full compatibility information at: http://www.hp.com/go/connect
Please consult the EBS connectivity matrix at: http://www.hp.com/go/ebs for connectivity information and the supported Fibre Channel HBAs shown in this QuickSpecs.
USB 2.0 port
HP ProLiant DL180 Generation 6
462828-B21
412911-B21
AH627A
462828-B21
N/A
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 50
QuickSpecs
HP ProLiant DL180 Generation 6
Storage
HP StorageWorks D2D
Backup Systems, iSCSI
D2D2500i
D2D4000i
HP StorageWorks D2D
Backup Systems, Fibre
Channel
D2D4000fc
Rack Mount Embedded Network Controller. If the server requires a hardware iSCSI initiator, the QLogic QLA4050 Host Bus
Adapter is recommended.
Rack Mount Direct server attach is not supported, requires connection via
SAN fabric. See: http://www.hp.com/go/connect
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 51
QuickSpecs
Power Specifications
HP 460W Power Supply
Part Number - AC 460W PSU
503296-B21
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal)
(Hz)
50/60
Nominal Input Voltage (Vrms)
Maximum Rated Output Wattage
100
460
Nominal Input Current (A rms)
Max Rated Input Wattage Rating
(Watts)
Max. Rated VA (Volt-Amp)
Efficiency (%) at Max. Rated
Output Wattage
5.5
526
548
87.5
Power Factor
Leakage Current (mA)
Max. Inrush Current (A peak)
Max. Inrush Current duration
(mS)
Maximum British Thermal Unit
Rating (BTU-Hr)
0.97
0.42
30
20
1794
HP 750W Power Supply
Part Number - AC 750W PSU
512327-B21
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal)
(Hz)
Nominal Input Voltage (Vrms)
Maximum Rated Output Wattage
Nominal Input Current (A rms)
50/60
100
750
8.9
857 Max Rated Input Wattage Rating
(Watts)
Max. Rated VA (Volt-Amp)
Efficiency (%) at Max. Rated
Output Wattage
Power Factor
894
87.5
0.97
Leakage Current (mA)
Max. Inrush Current (A peak)
Max. Inrush Current duration
(mS)
Maximum British Thermal Unit
Rating (BTU-Hr)
0.42
30
20
2925
0.97
0.50
30
20
2892
120
750
7.4
847
884
88.5
0.97
0.50
30
20
1773
120
460
4.5
520
542
88.5
HP ProLiant DL180 Generation 6
0.97
0.83
30
20
1725
208
460
2.6
505
527
91
0.97
0.87
30
20
1725
200
460
2.5
505
527
91
0.97
0.92
30
20
1715
220
460
2.4
503
524
91.5
0.97
0.96
30
20
1715
230
460
2.3
503
524
91.5
0.97
1.00
30
20
1715
240
460
2.2
503
524
91.5
0.97
0.83
30
20
2812
208
750
4.3
824
859
91
0.97
0.87
30
20
2812
200
750
4.1
825
859
91
0.97
0.92
30
20
2797
220
750
3.9
820
854
91.5
0.97
0.96
30
20
2797
230
750
3.7
820
854
91.5
0.97
1.00
30
20
2797
240
750
3.6
820
854
91.5
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 52
QuickSpecs
Power Specifications
HP 460W Platinum Power
Supply Part Number - AC
460W PSU
593188-B21
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal)
(Hz)
50/60
Nominal Input Voltage (Vrms)
Maximum Rated Output Wattage
Nominal Input Current (A rms)
Max Rated Input Wattage Rating
(Watts)
100
460
5.3
512
526
89.8
Max. Rated VA (Volt-Amp)
Efficiency (%) at Max. Rated
Output Wattage
Power Factor
Leakage Current (mA)
Max. Inrush Current (A peak)
Max. Inrush Current duration
(mS)
Maximum British Thermal Unit
Rating (BTU-Hr)
0.42
1747
HP 750W Platinum Power
Supply
Part Number - AC 460W PSU
593831-B21
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal)
(Hz)
Nominal Input Voltage (Vrms)
Maximum Rated Output Wattage
Nominal Input Current (A rms)
50/60
100
750
8.6
841 Max Rated Input Wattage Rating
(Watts)
Max. Rated VA (Volt-Amp) 863
89.2
Efficiency (%) at Max. Rated
Output Wattage
Power Factor
0.42
Leakage Current (mA)
Max. Inrush Current (A peak)
Max. Inrush Current duration
(mS)
Maximum British Thermal Unit
Rating (BTU-Hr)
2868
0.50
1722
0.50
2825
120
750
7.1
828
850
90.6
120
460
4.3
505
518
91.2
HP ProLiant DL180 Generation 6
208
460
2.5
493
506
93.2
0.83
1683
0.985
0.87
30
20
1682
200
460
2.4
493
506
93.3
0.92
1679
220
460
2.3
492
505
93.5
1678
230
460
2.2
492
505
93.6
0.96
1677
240
460
2.1
491
504
93.6
1.00
208
750
4.2
809
830
92.7
0.83
2761
0.985
0.87
30
20
2757
200
750
4.0
808
829
92.8
0.92
2753
220
750
3.8
807
828
93.0
2749
230
750
3.6
806
827
93.1
0.96
2747
240
750
3.4
805
826
93.2
1.00
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 53
QuickSpecs
Power Specifications
Optional Country Power Cords and Jumper Cords
WW HP 2m 15A C20 C13 Universal Jumper Cord
Brazil HP 1.83m 10A C13 NBR14136 Power Cord
HP ProLiant DL180 Generation 6
AF590A
AF591A
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 54
QuickSpecs
Technical Specifications
System Unit
HP ProLiant DL180 Generation 6
Dimensions (H x W x D)
3.45" x 17.64" x 28.23" in (8.76 x 44.80 x 71.71 cm)
(with bezel)
Weight
(approximate)
Maximum
(all hard drives, power supplies, and processors installed)
Minimum
(one hard drive, power supply, and processor installed)
45.0 lb (16.80 kg)
32.0 lb (11.94 kg)
Input Requirements
(per power supply)
BTU Rating
Rated Line Voltage
90 -- 132 VAC,
180 - 264 V
Rated Input Current
460 Watt
750 Watt
7.1 A (at 120 VAC)
3.5 A (at 240 VAC)
7.4 A (at 120 VAC)
3.6 A (at 240 VAC)
Rated Input Frequency 50 to 60 Hz
Rated Input Power
Maximum
460 & 750 watt - 852 W
460 Watt 1773 BTU/hr (at 120
VAC)
1715 BTU/hr (at 240
VAC)
750 Watts 2892 BTU/hr (at 120
VAC)
2797 BTU/hr (at 240
VAC
Power Specifications
To review typical system power ratings use the Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliantenergy-efficient
Power Supply Output
(per power supply)
System Inlet
Temperature
Click on the system of interest. Example: DL180 G6
Follow the instructions of the next screens.
Rated Steady-State
Power
460 W (at 100 VAC)
750 W (at 100 VAC)
460 W (at 200 VAC)
750 W (at 200 VAC)
Maximum Peak Power 460 W (at 100 VAC)
750 W (at 100 VAC)
460 W (at 200 VAC)
750 W (at 200 VAC)
Operating
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed.
System performance may be reduced if operating with a fan fault or above 30°C
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 55
QuickSpecs
Technical Specifications
HP ProLiant DL180 Generation 6
Relative Humidity
(non-condensing)
Altitude
Acoustic Noise
Non-operating
Operating
Non-operating
(86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, noncondensing.
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-condensing.
Operating
Non-operating
3050 m (10,000 ft). This value may be limited by the type and number of options installed.
Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA
74) and declared in accordance with ISO 9296 (ECMA 109).
Idle
LWAd
LpAm
Operating
LWAd
LpAm
5.3 B
38 dBA
5.3 B
38 dBA
NC362i Integrated Dual
Port Gigabit Server
Adapter
Network Interface
Integrated 10/100/1000BASE-T Transceiver
Combines a triple-speed IEEE 802.3TM - Compliant Media Access
Controller (MAC) with a triple-speed Ethernet transceiver.
Data Transfer Method
Compliant to x1 PCIe Specification
Controller
Intel® 82576
Network Transfer Rate 10Base-T (Half-Duplex)
10 Mb/s
10Base-T (Full-Duplex) 20 Mb/s
100 Mb/s 100Base-TX (Half-
Duplex)
100Base-TX (Full-
Duplex)
200 Mb/s
Connector
Cable Support
1000Base-TX (Half and
Full-Duplex)
RJ-45
2000 Mb/s
Performs all the physical layer functions for 10BASE-T, 100BASE-T, and 1000BASE-T Ethernet on standard Category 5 UT
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 56
QuickSpecs
Technical Specifications
HP 160GB 3G SATA
7.2K rpm LFF (3.5-inch)
Entry 1yr Warranty
Hard Drive
458945-B21
Smart Array P212
Controller
160GB 7,200 rpm
HP ProLiant DL180 Generation 6
Capacity
Height
Width
Depth
Interface
Transfer Rate
(Maximum)
Native Command
Queuing
Seek Time
(typical reads, including settling)
160,041MB
1.04 in (26.4 mm)
4.36 in (110.7 mm)
7.25 in (184.2 mm)
Serial ATA
3Gb/s
Supported
Single Track
Average
Full-Stroke
Rotational Speed
2.0 ms
<11 ms
23.0 ms
7,200 rpm
Physical Configuration Bytes/Sector
Logical Blocks
512
312,581,808
Operating Temperature41° to 131° F (5° to 55° C)
Disk Drive and
Enclosure Interface
Server Interface
SAS Speed
Cache Memory
3G SAS (Serial Attached SCSI)
1.5G SATA (Serial ATA)
SAS Connectors
1 internal/1 external (Mini-SAS) x8 wide port connectors
Cache Memory Speed DDR-2/533 MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s
maximum bandwidth.
x8 2.5G PCIe 2.0 provides 2GB/s maximum bandwidth.
x8 3G SAS provides 2.4GB/s maximum bandwidth.
Logical Drives
Supported
40-bit 256MB ECC protected cache; transportable with battery-backed upgrade.
NOTE: The 256MB cache is not battery-backed or transportable.
Up to 32 logical volumes
Host Memory
Addressing
RAID Support
64-bit, supporting greater than 4GB server memory space
RAID 6, 6+0 (Advanced Data Guarding)
NOTE: A minimum of 256 MB cache, battery kit, and Smart Array
Advanced Pack License Key upgrade is required to enable RAID 6, 6+0
RAID 5, 5+0 (Distributed Data Guarding)
NOTE: The 256 MB & Battery Kit upgrade is required to enable RAID 5,
5+0 support
RAID 1, 1+0 (Striping & Mirroring)
RAID 0 (Striping)
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 57
QuickSpecs
HP ProLiant DL180 Generation 6
Technical Specifications
Smart Array P410/410i
Controller
Disk Drive and
Enclosure Interface
6Gb/s SAS (Serial Attached SCSI)
3Gb/s SATA (Serial ATA)
2 internal (Mini-SAS) x8 wide port connectors
SAS Connectors
Cache Memory Speed DDR2-533MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s
maximum bandwidth.
Server Interface
x8 2.5G PCIe 2.0 provides 2GB/s maximum bandwidth
SAS Speed
Cache Memory
x8 6Gb/s SAS provides 24.8GB/s maximum bandwidth
40-bit 256MB ECC protected cache (72-bit 512MB BBWC module upgrades available); transportable with battery-backed upgrade
Up to 64 logical drives
Logical Drives
Supported
Host Memory
Addressing
RAID Support
64-bit, supporting greater than 4GB server memory space
RAID 6, 6+0 (Advanced Data Guarding)
NOTE: The minimum of 256 MB cache, battery kit, and Smart Array
Advanced Pack License Key upgrade is required to enable RAID 6, 6+0
RAID 5, 5+0 (Distributed Data Guarding)
NOTE: The 256 MB is required to enable RAID 5, 5+0 support of the
Smart Array P410i
RAID 1+0 (Striping & Mirroring)
RAID 0 (Striping)
Environment-friendly
Products and
Approach
End-of-life
Management and
Recycling
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green . To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green . These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment.
© Copyright 2010 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation.
Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less.
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010 Page 58
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement