Icron USB 3-2-1 Raven 3124 USB Extender User guide
The Icron USB 3-2-1 Raven 3124 is a 4-port USB 3.1 extender system that lets you connect USB devices up to 200m away using multimode fiber optic cabling. It supports USB 3.1 Gen 1/2 host controllers and devices with speeds up to 5 Gbps, and is backwards compatible with USB 2.0 devices. The Raven 3124 is a true plug-and-play solution with no software drivers required, and works with all major operating systems including Windows, macOS, Linux, and Chrome OS.
Reklama
Reklama
Icron USB 3-2-1 Raven
™
3124
4-Port USB 3.1, 200m Multimode Fiber
Point-to-Point Extender System
User Guide
Thank you for purchasing the USB 3-2-1 Raven™ 3124.
Please read this guide thoroughly.
This document applies to the following part numbers:
Model
North
American
System
European
System
United
Kingdom
System
Australia
System
Icron USB 3-2-1 Raven 3124
Japan
System
00-00437 00-00438 00-00439 00-00440 00-00441
FCC Radio Frequency Interference Statement Warning
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation.
CE Statement
We, Icron Technologies Corporation, declare under our sole responsibility that the USB 3-2-1 Raven™ 3124, to which this declaration relates, is in conformity with European Standards EN 55022, EN 55024, EN 55032 and
EN 61000.
IC Statement
This Class B digital apparatus complies with Canadian ICES-003 Issue 6.
WEEE Statement
The European Union has established regulations for the collection and recycling of all waste electrical and electronic equipment (WEEE). Implementation of WEEE regulations may vary slightly by individual EU member states. Please check with your local and state government guidelines for safe disposal and recycling or contact your national WEEE recycling agency for more information.
Product Operation and Storage
Please read and follow all instructions provided with this product, and operate for intended use only.
Do not attempt to open the product casing as this may cause damage and will void warranty. Use only the power supply provided with this product (if applicable). When not in use, product should be stored in a dry location between -20°C and 70°C.
©2018 All rights reserved.
Document #90-01579-A01
Contents
Optional USB Extender Mounting Options ...........................................................9
Introduction
This guide provides product information for the USB 3-2-1 Raven™ 3124, installation instructions and troubleshooting guidelines. The instructions in this guide assume a general knowledge of computer installation procedures, familiarity with cabling requirements and some understanding of USB devices.
note
NOTE: Notes provide additional information that could be useful.
CAUTION: Cautions provide important information about an operational requirement.
Product Contents
Your Raven 3124 extender system contains:
• LEX (Local Extender)
• REX (Remote Extender)
• USB 3.1 Gen 1 Cable
• LEX 24V DC 1A International Power Adapter
• REX 24V DC 2.71A International Power Adapter
• 2 x Country Specific Power Cables
• Quick Start Guide
Features
The Raven 3124 incorporates ExtremeUSB-C™ technology, enabling users to extend USB 3.1 beyond the standard 3m cable limit for USB 3.1 peripheral devices. This extender system is composed of two individual units, the LEX and the REX, and has the following key features:
• Up to 200m of extension when directly connected over OM3 multimode fiber
• Support for new USB 3.1 Gen 1/2 host controllers and devices (up to 5 Gbps)
• Support for all device USB types
• Backwards compatible to USB 2.0 devices
The Raven 3124 includes the ExtremeUSB-C™ suite of features:
• Transparent USB extension supporting USB 3, 2 and 1
• True plug and play; no software drivers required
• Works with all major operating systems: Windows®, macOS™, Linux® and Chrome OS™
note
The Raven 3124 only works with OM3 multimode fiber or higher grade.
3
The LEX Unit
The LEX unit connects to the computer using a standard USB 3.1 Gen 1 cable. Power for this unit is provided by the included 24V 1A adapter.
Front View
Power
1
Mode
2
Config
3
Status Link USB 2 USB 3
4
5 6 7
Rear View
Link
LAN USB 24V 1A
2
3
4
5
6
7
8
8
ITEM TYPE
1 Power LED
Mode
Config
Status LED
9
DESCRIPTION
10 11
LED is SOLID ON when DC is supplied to the extender unit. LED is OFF when no power is supplied by the AC Adapter
Reserved for manufacturer use.
Reserved for manufacturer use.
Link LED
USB 2 LED
USB 3 LED
LED is SOLID ON when system is functioning normally. LED BLINKS when system is booting OR to indicate a temperature warning in unison with the LINK, USB 2, and
USB 3 LEDs.
LED is SOLID ON when LEX is linked to an opposite REX. LED is OFF when there is no connection between the LEX and REX units.
LED is SOLID ON when an active USB 2 connection is established through the extender system. LED BLINKS when the USB 2 connection is suspended/asleep.
LED is OFF when no USB 2 connection is detected.
LED is SOLID ON when an active USB 3 connection is established through the extender system. LED BLINKS when the USB 3 connection is suspended/asleep.
LED is OFF when no USB 3 connection is detected.
LAN Port (100 Mbps) Ethernet pass through channel connects to a network or Ethernet device.
9 Link Port
10 USB Host Port
11 DC Power Port
Extension link Duplex LC fiber optic transceiver port.
USB 3 Type B receptacle used to connect LEX to USB 3 Host computer.
Locking connector for the included power adapter – accepts 24VDC 1A.
4
The REX Unit
The REX unit provides USB 3.1 Type A ports for standard USB devices and allows you to connect up to four USB devices directly. Additional devices may be connected by attaching up to three USB hubs to the REX. The REX is powered by an external AC 24V 2.71A adapter, supplying up to 1.2 Amp per USB port.
Front View
Power
1
Mode
Config
2 3
Status Link USB 2 USB 3
4
5 6 7
Rear View
10 10
LAN
Link
10
USB
10
USB USB USB 24V 2.71A
2
3
4
5
6
7
8
8
ITEM TYPE
1 Power LED
9
11
DESCRIPTION
LED is SOLID ON when DC is supplied to the extender unit. LED is OFF when no power is supplied by the AC Adapter.
Reserved for manufacturer use.
Mode
Config
Status LED
Link LED
Reserved for manufacturer use.
LED is SOLID ON when system is functioning normally. LED BLINKS when system is booting OR to indicate a temperature warning in unison with the LINK, USB 2, and USB 3 LEDs.
LED is SOLID ON when LEX is linked to an opposite REX. LED is OFF when there is no connection between the LEX and REX units.
USB 2 LED
USB 3 LED
LED is SOLID ON when an active USB 2 connection is established through the extender system. LED BLINKS when the USB 2 connection is suspended/asleep.
LED is OFF when no USB 2 connection is detected.
LED is SOLID ON when an active USB 3 connection is established through the extender system. LED BLINKS when the USB 3 connection is suspended/asleep.
LED is OFF when no USB 3 connection is detected.
LAN Port (100 Mbps) Ethernet pass through channel connects to a network or Ethernet device.
9 Link Port Extension link Duplex LC fiber optic transceiver port.
10 Device Ports (Type A) Accepts all USB devices.
11 DC Power Port Locking connector for the included power adapter – accepts 24VDC 2.71A.
5
Installation Guide
Installing the USB 3-2-1 Raven 3124 System
Requirements
To complete the installation, you will also require the following items that are not included with this system:
• USB compatible computer (host computer) with a USB compliant operating system
• USB compatible device(s)
• OM3 Fiber optic cabling
Fiber Optic Link Cabling
The LEX and REX extenders are interconnected by fiber optic cabling. Duplex multimode fiber cabling is required for the Raven 3124 for extending up to 200m using 50/125
μm OM3 grade cable. The cabling subsystem must provide a duplex connection with crossover, and must be terminated with Duplex LC connectors at both ends.
Host
USB Cable
OM3 Fiber Optic Link Cable
USB Devices
USB 3-2-1 up to 200m over MMF
LEX REX
LAN
IP Control
4.
1.
2.
3.
Optional Network Connections
Preparing Your Site
Before installing the Raven 3124 extender, you will need to prepare your site:
Place the computer where desired and set it up.
Ensure to locate the USB device(s) within the cable-length of the computer. If not, adjust the location of the device(s) and/or computer accordingly.
If you are using surface cabling, the Raven 3124 supports a maximum distance of 200m over OM3 multimode fiber.
If using premise cabling, ensure compatible fiber optic cabling is installed between the two locations and does not to exceed the specified distance.
6
Installing the LEX Unit
1. Place the LEX unit near the computer.
2. Assemble the power adapter and country specific power cord together and connect them into a
3. suitable AC outlet.
Connect the supplied USB 3.1 Gen cable between the LEX host port and a USB 3 port on the host
computer.
Connecting the LEX to the REX
With Surface Cabling:
1.
2.
Plug one end of the fiber optic cabling (not included) into the Link port on the LEX.
Plug the other end of the fiber optic cabling into the Link port on the REX.
With Premise Cabling:
1.
2.
3.
4.
Plug one end of a fiber optic patch cord (not included) into the Link port on the LEX.
Plug the other end of the patch cord into the fiber optic information outlet near the host computer.
Plug one end of the second fiber optic patch cord (not included) into the Link port on the REX.
Plug the other end of the second patch cord into the fiber optic information outlet near the USB
device.
Installing the REX Unit
1.
2.
Place the REX near the USB device(s).
Connect the power adapter to the REX.
Checking the Installation
1. On the LEX and REX units, check that the Power, Status, Link, USB 2 and USB 3 LEDs are on. If the Link LEDs are permanently off, then the cabling between the LEX and REX units may not be installed properly or is defective.
2. For Windows users (XP, 7, 8, 8.1, 10), open Device Manager to confirm that the extender system has been installed correctly. Expand the entry for Universal Serial Bus controllers by clicking the “+” sign.
If the extender system has been installed correctly, you should find two separate instances of
“Generic SuperSpeed USB Hub” listed.
note
To open Device Manager in Windows XP:
Right click “My Computer” then select: Properties >> Hardware tab >> Device Manager
note
Open the Start Menu, right click on “Computer” then select: Manage >> Device Manager
note
Right click the Start Menu and then select: Device Manager
7
3. For macOS users, open the System Profiler to confirm that the extender system has installed correctly.
In the left-hand column under Hardware, select “USB” and inspect the right hand panel. If the extender has been installed correctly, you should find it listed as two separate instances of “Hub” under the USB SuperSpeed Bus.
note
To open System Profiler in macOS:
Open the Finder, select Applications, then open the Utilities folder and double click on the System Profiler icon.
4. If the extender system is not detected correctly or fails to detect, please consult the Troubleshooting section in this guide.
Connecting a USB Device
1.
2.
3.
Install any software required to operate the USB device. Refer to the documentation for the USB device, as required.
Connect the USB device to the device port on the REX.
Check that the device is detected and installed properly in the operating system.
Compatibility
The USB 3-2-1 Raven 3124 complies with USB 2.0 and USB 3.1 Gen 1 specifications governing the design of
USB devices. However, there is no guarantee that all USB devices or hosts will be compatible as there are a number of different characteristics that may impact the operation of USB devices over extended distances.
Optional Ethernet Pass Through Connection
The Raven 3124 offers a 100 Mbps Ethernet pass through connection that can be used for a variety of purposes including:
• Connecting network devices
• Providing remote network access to the same location as the REX unit
• Leveraging existing cabling to provide USB 3-2-1 connectivity without losing network connectivity
LAN
Up to 200m over OM3 MMF
Network
Device
Up to 100m
CAT 5e/6/7
LEX REX
Up to 100m
CAT 5e/6/7
Connect any network device or access port into the RJ45 socket label “LAN” using up to 100 meters of standard CAT 5e, 6 or 7 cabling.
8
Optional USB Extender Mounting Options
The bottom of the enclosure features four convenient pre-drilled holes for optional mounting. Based on your requirements, choose from two available mounting options:
1. USB Extender Mounting Kit (Purchased separately Order Part #10-00620 USB Mounting Kit - Silver)
2. USB Extender Direct Surface Mounting (Using your own hardware, stencil provided on page 10)
OPTION 1: USB Extender Mounting Kit - each kit includes:
• 2 mounting brackets
• 4 (M3) locking washers
• 4 (M3 x 10mm) Phillips screws
• Mounting bracket installation guide (see diagram below)
1 kit required to mount per LEX or REX
Using a Phillips screwdriver, in the order as illustrated below, fasten and secure the provided screws, locking washers and brackets into place.
Once the bracket mounting is secured onto the extender, it is ready for mounting onto a surface. Please note you will need to provide your own screws to secure the extender using the available slots on each bracket.
9
OPTION 2: USB Extender Direct Surface Mounting (using your own hardware)
The bottom of the enclosure features four pre-drilled holes for optional surface mounting.
Distance between the enclosure mounting holes:
42.0mm mounting hole
1. Mark the center point of each of the four holes on your mounting surface either by directly measuring or
printing a stencil from www.icron.com/pdf/R-M-stencil.pdf .
2. Hardware recommendation: M3 locking washers and M3 screws (4 of each per extender) noting
screw length will depend upon thickness of mounting surface.
3. Drill through each of the four-hole markings on the mounting surface using a 3.97mm (5/32”) drill bit.
4. Align the bottom enclosure holes to the newly drilled out holes on the mounting surface.
5. Place a locking washer on each of the four screws and using a screwdriver, fasten the extender into place.
note
Do not exceed a screw depth of 10mm (0.4”) into the unit or damage may occur.
Direct Surface Mounting Measurement Stencil
The stencil illustration pictured below is only 50% of the original size. To access this stencil file (to scale), simply go to: www.icron.com/pdf/R-M-stencil.pdf
.
4.0mm (5/32”) in 4 places
42.0mm
(3.0315”)
205.5mm (8.0905”)
10
Troubleshooting
The following table provides troubleshooting tips. The topics are arranged in the order in which they should be executed in most situations. If you are unable to resolve the problem after following these instructions, please contact Icron Technologies’ Technical Support for further assistance.
PROBLEM CAUSE SOLUTION
ALL LEDs are
OFF on the LEX and/or REX.
POWER LED is
ON, STATUS LED is OFF.
Link LEDs on the
LEX and REX are
OFF.
1. The LEX and/or REX is not
receiving power from the
AC power adapter.
1. The unit has malfunctioned
and requires re-programming.
1. There is no connection
between the LEX and REX
units.
1. Ensure that the AC power adapter is properly
connected to the LEX and/or REX.
2. Check that the AC adapter is connected to a live
source of AC power. Check that the LEX and/or
REX Power LED is illuminated.
1. Contact Technical Support for assistance.
1. Ensure that a crossover OM3 multimode fiber
optic cable of no more than 200m is connected
between the LEX and REX.
LINK LEDs on the LEX and REX are SOLID ON, but the USB 2 and USB 3 LEDs are OFF.
The USB 2 LED is SOLID ON, but the USB 3 LED is
OFF.
1. The host computer is not
powered on.
2. The LEX is not connected to a
computer.
3. The host computer does not
support USB Hubs.
4. The unit is malfunctioning.
1. The LEX is not connected to a
USB 3 port.
2. The LEX is connected to the
host using a USB 2 cable.
2. Connect a short fiber optic patch cable between
the LEX and REX. Recheck the link status. If the
LINK LED is now SOLID ON, the previous cable is
defective or not capable of supporting the link.
1. Disconnect all USB devices from the REX.
2. Disconnect LEX from the host computer.
3. Disconnect AC adapters from LEX and REX.
4. Reconnect the LEX to the host computer.
5. Reconnect the AC adapters to the LEX and REX.
6. Check that the LEX and REX have enumerated as
USB hubs in Windows Device Manager, macOS
System Profiler or using “Isusb” command in a
Linux Terminal.
7. If the problem is not resolved, contact Technical
Support .
1. Ensure that the LEX is connected to a USB 3 port
on the host computer.
2. Ensure that the included USB 3.1 Gen 1 cable is
being used between the host computer and LEX.
3. Cold boot the host computer.
3. The USB 3 cable connecting
the LEX to the host computer
is defective.
4. Replace the USB 3.1 Gen 1 cable with a different
cable.
4. The host computer’s USB 3
controller has malfunctioned.
11
5. If the problem is not resolved, contact Technical
Support .
PROBLEM
The USB 3 LED is
SOLID ON, but the
USB 2 LED is OFF.
Both the LEX and
REX extenders are working, but the USB 2 or USB
3 LEDs on the
LEX and REX are blinking.
CAUSE
1. The USB cable connecting
the LEX to the host computer
is defective.
SOLUTION
1. Ensure that the included USB 3.1 Gen 1 cable is
being used between the host computer and
LEX.
2. The host computer’s USB 2.0
controller has malfunctioned.
2. Cold boot the host computer.
3. The host computer does not
support USB 2.
3. Replace the USB 3.1 Gen 1 cable with a different
cable.
1. The LEX and/or REX is in
suspend mode. For a variety of
reasons, the host computer
may place the LEX/REX into
suspend mode. Typically, it
is because there are no USB
devices attached, the USB
device is asleep, or the host
computer is in a sleep state or
hibernating.
4. If the problem is not resolved, contact Technical
Support .
1. Recover/resume the operating system from
sleep or hibernate modes (refer to your
operating system’s documentation).
2. Connect a USB device to the REX.
3. Use the connected device.
4. If the problem persists, contact Technical
Support .
ALL LEDs on both the LEX and
REX units are
SOLID ON, but the USB device is not operating correctly, or is detected as an
“Unknown Device” in the operating system.
1. The USB device is
malfunctioning.
2. The computer does not
recognize the USB device.
3. The application software for
the USB device is not
operating.
4. The USB extender is
malfunctioning.
1. Disconnect the extender from the computer.
2. Connect the USB device directly to the host
computer.
3. If the device does not operate as expected,
consult the user documentation for the device.
4. Update the host computer BIOS, chipset or USB
controller drivers from the manufacturer’s
website.
5. If the device operates as expected when directly connected to the computer, connect another device to the extender and reconnect it to the host computer.
6. If the second device does not operate, the extender may be malfunctioning. Contact
Technical Support for assistance.
7. If the second device operates as expected, then the first device may not be compatible with this extender. Contact Technical Support .
12
PROBLEM
A USB 3 device is not enumerating as USB 3, or the operating system is notifying the user that the device can
“Perform Faster if connected to a
USB 3 port”.
CAUSE
1. The USB device is
malfunctioning.
2. The computer does not
recognize the USB device.
3. The application software for
the USB device is not
operating.
4. The USB 3 port on the
computer is malfunctioning.
5. The USB extender is
malfunctioning.
SOLUTION
1. Disconnect the extender from the computer.
2. Connect the USB 3 device directly to the host
computer.
3. If the device does not operate as expected as a
USB 3 device, consult the user documentation
for that device or try a different USB port on the
host computer.
4. Update the host computer BIOS, chipset or USB
controller drivers from the manufacturer’s
website.
5. If the device operates as USB 3 device when
directly connected to the computer, connect
another USB 3 device to the extender and
reconnect it to the host computer.
6. If the second device does not operate as a
USB 3 device, the extender may be
malfunctioning. Contact Technical Support
for assistance.
7. If the second device operates as a USB 3
device as expected, the first device may not
be compatible with this extender. Contact
Technical Support .
All LEDs are flashing and the system is operational.
All LEDs are flashing and the system is NOT operational.
1. Unit is or was operating at an
unsafe temperature.
1. Unit has exceeded safe
operating temperature.
LEDs are scrolling
LEFT to RIGHT, starting with
STATUS.
1. Unit is programming.
1. Check ambient temperature. Ensure
temperature does not exceed 50°C (122°F).
2. Power cycle the unit to remove LED status.
1. Remove external sources of heat or change
location of the unit.
2. Power cycle the unit to return to operation.
1. Wait for the unit to finish programming.
13
Warranty Information
Limited Hardware Warranty
Icron Technologies Corporation warrants that any hardware products accompanying this documentation shall be free from significant defects in material and workmanship for a period of two years from the date
of purchase. Icron Technologies Corporation’s hardware warranty extends to Licensee, its customers and end users.
The Warranty does not include repair of failures caused by: misuse, neglect, accident, modification, operation outside a normal operating environment, failure caused by service of the device by nonauthorized servicers, or failure caused by a product for which Icron Technologies Corporation is not responsible. Opening the enclosures will void warranty.
Hardware Remedies
Icron Technologies Corporation’s entire liability and the Licensee’s exclusive remedy for any breach of warranty shall be, at Icron Technologies Corporation’s option, either (a) return of the price paid or (b) repair or replacement of hardware; which will be warranted for the remainder of the original warranty period or
30 days, whichever is longer. These remedies are void if failure of the hardware has resulted from accident, abuse, or misapplication.
Limitation of Liability
The hardware warranty set forth in this agreement replaces all other warranties. Icron Technologies
Corporation expressly disclaims all other merchantability and fitness for a particular purpose and noninfringement of third-party rights with respect to the hardware.
Icron Technologies Corporation dealer, agent, or employee is not authorized to make any modification extension or addition to this warranty. Under no circumstances will Icron Technologies Corporation, its suppliers or licensors be liable for any costs of procurement or substitute products or services, lost profits, loss of information or data, or any other special, indirect, consequential, or incidental damages arising in any way out of the sale of, use of, or inability to use Icron Technologies Corporation product or service, even if Icron Technologies Corporation, its suppliers or licensors have been advised of the possibility of such damages. In no case shall Icron Technologies Corporation, its suppliers and licensors’ liability exceed the actual money paid for the products at issue.
Since some jurisdictions do not allow the limitation of implied warranties of liability for incidental, consequential, special or indirect damages, the above limitation may not always apply. The above limitation will not apply in case of personal injury where and to the extent that applicable law requires such liability.
Obtaining Warranty Service
To obtain warranty service, you must first contact Icron Technologies Corporation within the warranty period for a Return Material Authorization (RMA) number. Icron Technologies Corporation will not accept returns without an authorized RMA number. Prior to contacting Icron Technologies Corporation, be sure you have recorded the serial numbers of the LEX and REX. Package the product appropriately for safe shipment and mark the RMA number on the outside of the package. The package must be sent prepaid to Icron Technologies Corporation. We recommend that you insure it or send it by a method that provides for tracking of the package. The repaired or replaced item will be shipped to you, at Icron Technologies
Corporation’s expense, not later than thirty days after Icron Technologies Corporation receives the defective product.
14
Specifications
RANGE
Point-to-Point
USB DEVICE SUPPORT
Maximum Throughput
Traffic Types
Device Types
Maximum Number of Devices and/or Hubs
LOCAL EXTENDER (LEX)
USB Connector
Link Connector
Network Pass Through:
Dimensions
Enclosure Material
Power Supply
REMOTE EXTENDER (REX)
USB Connector
Link Connector
Network Pass Through:
Dimensions
Enclosure Material
Available Current
Power Supply
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Operating Humidity
Storage Humidity
COMPLIANCE
EMC
Environmental
SUPPORT
Warranty
Up to 200m (656 ft) over OM3 or better multimode fiber
5 Gbps
All Traffic Types
All Device Types
Up to 30 devices
1 x USB 3.1 Gen 1 Type B Receptacle
1 x Duplex LC
1 x RJ45
137.3mm x 232.1mm x 33.0mm (5.4” x 9.1” x 1.3”)
Silver Anodized Aluminum
100-240V AC Input, 24V 1A DC Output
4 x USB 3.1 Gen 1 Type A Receptacles
1 x Duplex LC
1 x RJ45
137.3mm x 232.1mm x 33.0mm (5.4” x 9.1” x 1.3”)
Silver Anodized Aluminum
Up to 1.2 Amp (6W) to each USB port
100-240V AC Input, 24V 2.71A DC Output
0°C – 50°C (32°F – 122°F)
-20°C – 70°C (-4°F – 158°F)
20% to 80% relative humidity, non-condensing
10% to 90% relative humidity, non-condensing
FCC (Class B), CE (Class B)
RoHS2 (CE)
2-year
15
Contacting Technical Support
If you are experiencing problems not referenced in the Troubleshooting section, contact Icron Technical
Support:
www.icron.com/support
Tel: +1 604 638 3939
To help us serve you better, please include the following information with your technical support request:
• Host computer make and model
• Type of Operating System installed (e.g. Windows 10, macOS 10.12, etc.)
• Part number and serial number for both the LEX and REX units
• Make and model of any USB device(s) attached to this extender system
• Description of the installation such as Host computer model, transmission media used and information about the USB device(s)
• Description of the problem
Address the returned product to:
RMA Coordinator
Icron Technologies Corporation
4664 Lougheed Highway, Suite 221
Burnaby, BC Canada
V5C 5T5
Contacting Sales
Email:
Tel: +1 604 638 3920
16
Technical Glossary
USB 3 and USB 2.0 Cables
USB cables have two distinct full-sized connectors. The Type A connector is used to connect the cable from a
USB device to the Type A port on a computer or hub. The Type B connector is used to attach the USB cable to a USB device.
USB Type A port USB Type A connector
USB 3 Type A connector
USB Type B port USB Type B connector
USB 3 Type B port
USB 3 Type B connector
Duplex LC
When a crossover fiber-optic cable is called for, the cable has the transmit signal on one end connected to the receive signal at the other end.
17
Icron Technologies Corporation
4664 Lougheed Highway, Suite 221
Burnaby, BC Canada
V5C 5T5
Tel: +1 604 638 3920
Fax: +1 604 638 3930
www.icron.com
18
Stiahnuť