Sloan 3790011 8110/8111 Flush Valve Dimensions Guide
Advertisement
Advertisement
Sloan
®
Model
8110/8111 u
Description
Exposed, Battery Powered, Sensor Activated, Sloan ® Optima ®
Plus
Model Water Closet
Flushometer for floor mounted or wall hung top spud bowls.
u u
Flush Cycle
£ Model 8111 Low Consumption (1.6 gpf/6.0 Lpf)
£ Model 8110 Water Saver (3.5 gpf/13.2 Lpf)
Variations
£ TP Trap Primer
£ DFB Dual Filtered Fixed Bypass Diaphragm
£ YO Bumper on Angle Stop (for open front seat without cover) u
Specifications
Quiet, Exposed, Diaphragm Type, Chrome Plated Closet Flushometer for either left or right hand supply with the following features:
• High Chloramine Resistant PERMEX ® Synthetic Rubber Diaphragm with Linear Filtered
Bypass and Vortex Cleansing Action™
• ADA Compliant OPTIMA Plus ® Battery Powered Infrared Sensor for automatic “No
Hands” operation
• Infrared Sensor with Multiple-focused, Lobular Sensing Fields for high and low target detection
• Latching Solenoid Operator
• Engineered Plastic Cover with replaceable Lens Window
• User friendly three (3) second Flush Delay
• Courtesy Flush ® Override Button
• Four (4) Size AA Batteries factory installed
• “Low Battery” Flashing LED
• Infrared Sensor Range Adjustment Screw
• Initial Set-up Range Indicator Light (first 10 minutes)
• Chrome Plated Metal Handle Cap
• 1” I.P.S. Screwdriver Bak-Chek ® Angle Stop
• Vandal Resistant Stop Cap
• Adjustable Tailpiece
• Vacuum Breaker with Flush Connection
• Spud Coupling and Spud Flange for 1½” Top Spud
• Sweat Solder Adapter with Cover Tube and Cast Wall Flange
• High Copper, Low Zinc Brass Castings for Dezincification Resistance
• No External Volume Adjustment to Ensure Water Conservation
• Low Consumption Flush Accuracy
• Stop Seat and Vacuum Breaker Molded from PERMEX ® Rubber Compound for
Chloramine Resistance
• 100% of the energy used in manufacturing is offset with Renewable Energy Sources
– Wind Energy
Valve Body, Tailpiece and Control Stop shall be in conformance with ASTM Alloy
Classification for Semi-Red Brass. Valve shall be in compliance with the applicable sections of ASSE 1037. Installation conforms to ADA requirements.
See Accessories Section and OPTIMA Accessories Section of the Sloan catalog for details on these and other OPTIMA
Plus
® Flushometer variations.
Sloan Valve Company is buying renewable energy certificates to meet 100% of the company’s purchased electricity use at its Franklin Park, Illinois facility.
Sloan Optima Plus 8110/8111 S.S. — Rev. 0b (07/11)
Battery Powered Flushometers
•
C u y
Am erican
A c o m plian t
•
C u y
Am erican
A c o m plian t
Made with
Renewable Energy u u u
ADA Compliant
Automatic
Sloan OPTIMA
Plus
® equipped Flushometers provide the ultimate in sanitary protection and automatic operation. There is no need for
AC hookups or wall alterations. The Flushometer operates by means of a battery powered infrared sensor. Once the user enters the sensor’s effective range and then steps away, the Flushometer
Solenoid initiates the flushing cycle to flush the fixture.
Hygienic
Made with
Renewable Energy
User makes no physical contact with the Flushometer surface except to initiate the Override Button when required. Helps control the spread of infectious diseases.
u
Economical
Automatic operation provides water usage savings over other flushing devices. Reduces maintenance and operation costs.
u
Warranty
3 year (limited)
This space for Architect/Engineer approval
Job Name
Model Specified
Variations Specified
Customer/Wholesaler
Contractor
Architect
Date
Quantity
The information contained in this document is subject to change without notice.
Hecho con
Energía Renovable
Hecho con
Energía Renovable
Spanish
8110/8111 u
Description
Exposed, Battery Powered, Sensor Activated, Sloan ® Optima ®
Plus
Model Water
Closet Flushometer for floor mounted or wall hung top spud bowls.
u
Flush Cycle
£ Model 8111 Low Consumption (1.6 gpf/6.0 Lpf)
£ Model 8110 Water Saver (3.5 gpf/13.2 Lpf)
2¼” MIN.
(57 mm)
ELECTRICAL SPECIFICATIONS
u
Control Circuit
Solid State
6 VDC Input
8 second Arming Delay
3 second Flush Delay u u u u u
OPTIMA Sensor Type
Active Infrared
OPTIMA Sensor Range
Nominal 22”-42” (559 mm-1067 mm), adjustable ± 8” (203 mm) u u
Battery Type
Four (4) ‘AA’ Alkaline
Battery Life
3 years @ 4,000 flushes/month
Indicator Lights
Range Adjustment/Low Battery
Operating Pressure
15-100 psi (104-689 kPa)
Sentinel Flush
Once Every 24 Hours After the Last
Flush
OPERATION
1. A continuous, invisible light beam is emitted from the
OPTIMA Plus Sensor.
2. As the user enters the beam’s effective range (22” to 42”) the beam is reflected into the OPTIMA Plus
Scanner Window and transformed into a low voltage electrical circuit.
Once activated, the Output
Circuit continues in a “hold” mode for as long as the user remains within the effective range of the Sensor.
VALVE ROUGH-IN
11½”
(292 mm)
2¼” (57 mm) MIN.
16½”
(419 mm)
C/L OF FIXTURE
1” I.P.S.
(25 mm DN) SUPPLY
4¾”
(121 mm)
C/L OF
FIXTURE
16½”
(419 mm)
3. When the user steps away from the OPTIMA Plus
Sensor, the circuit waits 3 seconds (to prevent false flushing) then initiates an electrical signal that operates the Solenoid. This initiates the flushing cycle to flush the fixture. The Circuit then automatically resets and is ready for the next user.
4 ¾”
(121 mm)
5”
(127 mm)
C/L OF
SUPPLY
1” I.P.S.
SUPPLY
(DN 25 mm)
11½”
(292 mm)
C/L OF
FIXTURE
When installing the Optima Plus in a handicap stall:
Per the ADA Guidelines (section 604.9.4) it is recommended that the grab bars be split or shifted to the wide side of the stall.
FINISHED WALL
C/L OF WASTE
FINISHED FLOOR
SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131
Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380 • www.sloanvalve.com
Copyright © 2011 Sloan Valve Company Sloan Optima Plus 8110/8111 S.S. — Rev. 0b (07/11)
Download