MicroRAE Data Sheet


Add to my manuals
2 Pages

advertisement

MicroRAE Data Sheet | Manualzz

MicroRAE

Wireless 4-Gas Monitor

The MicroRAE four-gas portable detector brings enhanced userfriendliness and flexibility to wireless gas detection. This enables continuous, instant visibility of safety threats for faster, more informed decisions, to protect workers, facilities, and the environment, and to optimize operations.

The MicroRAE is a wireless diffusion detector that simultaneously monitors up to four gases, including hydrogen sulfide, carbon monoxide, oxygen and combustibles (LEL). With its different wireless connectivity options the MicroRAE can deliver real-time instrument readings and alarm status to other wireless offerings such as ConneXt

Plus, ConneXt Pro, ConneXt Loneworker 4 and Safety Communicator.

• Man Down Alarm with real-time remote wireless notification 1

• GPS module for location

• Bluetooth ® low energy connection to a Smart Phone device for uplink data communication and device configuration.

• Remote notification & Panic function

• Fully automated bump testing and calibration with AutoRAE 2 ®

KEY FEATURES

• Honeywell ConneXt compatible with Mesh and Wifi wireless configurations

• Compact and lightweight

• IP-67 water- and dust-resistant case

• Strong, protective, concussion-proof design

• Real-time gas concentration readings, location, alarm and status enabled by state of-the-art wireless technology

• Unmistakable five-way local and remote notification of alarm conditions

• Short bump test & calibration time

• Global approval for worldwide acceptance

• Filtered LEL sensor options to inhibit sensor poisoning

INDUSTRIES

Personal protection and general safety and compliance in:

• Lone Worker Applications

• Oil and Gas

• Waste water treatment

• Utilities

• Telecommunications

• Firefighting

• Petrochemicals

• Construction

MicroRAE

Wireless 4-Gas Monitor

SPECIFICATIONS

Instrument Specifications

Size

Weight

Sensors

Battery

Running time

Display Graphic

Keypad

Direct Readout

Alarms

Datalogging

4.6" H x 3.0(2.6)3.0" W x 0.9” D

117 mm H x 76(66)74 mm W x 24 mm D

7.03 oz (206 g) including Li-ion battery and clip

 LEL Catalytic bead for combustibles

 Liquid Oxygen (O

2

)

 Electrochemical Sensor for CO, H

2

S, HCN

Rechargeable Li-ion

15 hours continuous non-wireless

11 hours continuous wireless

Note: All battery specifications at 68° F (20° C); lower temperatures and alarm conditions will affect runtime.

Monochrome display

1.73" W x 1.29" H (44 mm x 33 mm) with 2 color back light modes

Two-button operation

Real time reading of gas concentration and Man Down indicators

Multiple units display options

Wireless and GPS ON/OFF and reception quality

STEL, TWA, peak, and minimum values

Intelliflash and policy enforcement indicators

Multi-tone 100dB buzzer (at 11.8"/ 30 cm, typical), vibration alarm, and flashing LEDs and on-screen indication of alarm conditions

Alarms: latching, non latching or manual override

Additional diagnostic alarm and display message for low battery

Wireless connectivity alarm

Man Down Alarm and real-time remote wireless notification

Continuous datalogging (6 month for 4 sensors at 1-minute intervals)

User-configurabel datalogging intervals (from 1 to 3,600 seconds)

Communication &

Data Download

Data download and instrument set-up and upgrades on PC via Travel

Charger

Wireless data and status transmission via built-in RF modem (optional)

Wireless Network RAE Dedicated Wireless Mesh network or Standard WiFi

Wireless Range

(Typical)

EMC/RFI

IP Rating

Calibration

Up to 650 ft (200m) for sub1GHz Mesh Radio

Up to 330 ft (100m) for WiFi

Up to 15 ft (5m) for BLE

EMC directive: 2004/108/EC

3

3

IP-67

Two-point calibration (manual, or automatic with AutoRAE 2)

Safety

Certifications

Temperature

Humidity

Attachments

Warranty

US & Canada: Class I, Division 1, Groups A, B, C and D

II 2G Ex ia d IIC T4 Gb

I M1 EX ia I Ma

-4° to 140° F (-20° to 60° C) for T4 temperature code

0% to 95% relative humidity (non-condensing)

Stainless-steel alligator clip: wrist wrap (optional)

2-year warranty on device and sensors 2

Wireless ISM license free band. IEEE 802.15.4 Sub 1 GHz

IEEE 802.11 bands b/g 2.4 GHz

Wireless Approvals FCC Part15, CE R&TTE, Bluetooth 4.0, GPS, Others 4

Default Sensor Specifications

Gas Monitor

Oxygen (O

2

)

Combustible

Carbon Monoxide (CO)

Range

0 to 30.0%

0 to 100% LEL

0 to 1,000 ppm

Hydrogen Sulfide (H

2

S)

Hydrogen Cyanide (HCN)

0 to 100 ppm

0 to 50 ppm

Resolution

0.1%

1% LEL

0 – 250 ppm / 1 ppm

250 – 1,000 ppm / 3 ppm

0 – 50 ppm / 0.1 ppm

50 – 100 ppm / 1 ppm

0.2 ppm

ORDERING INFORMATION

• Refer to the Portables Pricing guide for monitor configurations and accessories

OPTIONAL ACCESSORIES

• AutoRAE 2 Automatic Test and Calibration Systems

• Gang Charger (5 units)

• Auxiliary filter

• Hand pump kit

• Truck mount charger

1 Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission

2 Against factory defects

3 Receiving > 80%

4 Contact RAE Systems for country specific wireless approvals and certificates.

Specifications are subject to change

CORPORATE HEADQUARTERS

RAE Systems by Honeywell

3775 North First Street

San Jose, CA 95134 USA

[email protected]

DS-1121-01

WORLDWIDE SALES OFFICES

USA/Canada 1.877.723.2878

Europe +800.333.222.44/+41.44.943.4380

Middle East +971.4.450.5852

China +86.10.5885.8788-3000

Asia Pacific +852.2669.0828

www.raesystems.com

advertisement