Below you will find brief information for Talent TE214S, Talent TE124S, Talent TE64, Talent TE313S, Talent TE153S, Gem GD603, Gem GD103, Gem GD502-DS. This user manual will instruct you on how to set up, operate, and maintain your Sartorius balance/scale with a variety of applications, including basic weighing, taring, and calibration. You will also find detailed explanations of the menu codes and ISO/GLP-compliant record output.
Advertisement
Advertisement
Operating Instructions Sartorius Talent, M-power Sartorius Gem, Gold Electronic Analytical and Precision Balances and Precious Metal Scales 98648-012-13 Contents Warnings and Safety Precautions Contents . . . . . . . . . . . . . . . 2 Warnings and Safety Precautions . 2 Getting Started . . . . . . . . . . . 3 Operation . . . . . . . . . . . . . . Overview of Display and Operating Elements . . . . . . . Basic Weighing Function . . . . . . Calibration/Adjustment . . . . . . . 7 7 8 9 Application Programs . . . . . . . . 10 Net-Total Formulation/ Second Tare Memory . . . . . . . . 10 Counting . . . . . . . . . . . . . . . 11 Weighing in Percent . . . . . . . . . 12 Weigh Averaging . . . . . . . . . . . 13 Toggling Between Weight Units . . 14 Configuring the Balance/ Scale (Menu Codes) Setting the Parameters (Menu Codes) . . . . . . . . . . . . 15 Balance/Scale Operating Menu (Overview) . . . . . . . . . . . . . . 16 ISO/GLP-compliant Printout . . . . 18 Data Interface . . . . . . . . . . . . 20 Error Codes . . . . . . . . . . . . . 21 Care and Maintenance . . . . . . . 22 Instructions for Recycling . . . . . 23 Overview Specifications . . . . . . . . . . . . 24 Accessories (Options) . . . . . . . . 33 Declaration of Conformity . . . . . . 35 2 Safety To prevent damage to the equipment, please read these operating instructions carefully before using your balance/scale. ! Do not use this balance/scale in a hazardous area/location. ! Use only a commercially available non-rechargeable or rechargeable battery: 8+ AA, Mignon ! Make absolutely sure to unplug the balance/scale from AC power before you connect or disconnect a peripheral device. ! Exposure to excessive electromagnetic disturbance can cause the readout value to change. Once the disturbance has ceased, the instrument can be used again in accordance with its intended use. Setting up the Balance/Scale ! Warning when using pre-wired RS-232 connecting cables: The pin assignments in RS-232 cables purchased from other manufacturers may be incompatible with Sartorius balances/scales. Be sure to check the pin assignment against the chart on page 19 before connecting the cable, and disconnect any lines that do not match. – Connect only Sartorius accessories and options, as these are optimally designed for use with your Sartorius balance/scale. Do not try to solve any problems on your own. The operator shall be responsible for any modifications to Sartorius equipment and for any connections of cables or equipment not supplied by Sartorius and must check and, if necessary, correct these modifications and connections. On request, Sartorius will provide information on the minimum operating specifications (in accordance with the standards for defined immunity to interference). – Do not open the balance/scale housing. If the seal is broken, this will result in forfeiture of all claims under the manufacturer’s warranty. Getting Started Storage and Shipping Conditions – Do not expose the balance/scale to extreme temperatures, blows, shocks, vibration or moisture. Unpacking the Balance/Scale After unpacking the balance/scale, check it immediately for any visible damage $ If you see any sign of damage, proceed as directed in the chapter entitled “Care and Maintenance,” under the section on “Safety Inspection” $ Save the box and all parts of the packaging until you have successfully installed your balance/scale in case you need to return it. Before packing your balance/scale, unplug all connected cables to prevent damage. Equipment Supplied – Balance/scale – Weighing pan – Pan support (only on models with a round weighing pan) – Gem tray (only with GE and GD models) – AC adapter, plug type Additionally supplied with AZ214, AZ124, AZ64, TE214S, TE124S, TE64, GD603, GD103, GD502-DS models: – Shield ring – Shield plate – Dust cover Additionally supplied with TE313S, TE153S, GD252 models: – Glass draft shield with cover Additionally supplied with GD252-DS, GD502-DS models: – Draft shield chamber with sliding doors – 50-g calibration weight (F1) – – – – Installation Instructions When choosing a location to set up your balance/scale, observe the following: Avoid placing the balance/scale in close proximity to a heater or otherwise exposing the balance/scale to heat or direct sunlight Protect the balance/scale from drafts that come from open windows or doors Avoid exposing the balance/scale to extreme vibrations during weighing Do not expose the balance/scale to extreme moisture over long periods Conditioning the Balance/Scale Moisture in the air can condense on the surfaces of a cold balance/scale whenever it is brought into a substantially warmer place. If you transfer the balance/scale to a warmer area, make sure to condition it for about 2 hours at room temperature, leaving it unplugged from AC power. Additionally supplied with TE313S-DS, TE153S-DS models: – Draft shield chamber with sliding doors 3 Setting up the Balance/Scale Balances/scales with a draft shield chamber with sliding doors Place the components listed below inside the chamber in the order given: – Shield plate – Shield ring (not for models TE313S-DS, TE153S-DS) – Pan support – Weighing pan – Gem tray (only with GD models) Balances/Scales with a Glass Draft Shield Place the components listed below inside the chamber in the order given: – Draft shield base – place it on the balance/scale so that the edge for fitting the glass draft shield faces upwards and turn it until it is firmly in place – Pan support – Weighing pan – Glass draft shield – Gem tray (only with GD models) – Draft shield cover – place it on the balance/scale so that the edge faces downwards Balances/Scales with a Round Weighing Pan Place the components listed below inside the chamber in the order given: – Pan support – Weighing pan – Gem tray (only with GE models) Balances/Scales with a Rectangular Weighing Pan Place the weighing pan on the balance/scale Gem tray (only with GE models) 4 Connecting the Balance/Scale to AC Power/ Safety Precautions Use only original Sartorius AC adapters: – for Europe: 6971948 Insert the right-angle plug into the jack Plug AC adapter into electrical outlet The ground terminal is connected to the balance/scale housing, which can be additionally grounded for operation. Using a Non-Rechargeable/Rechargeable Battery (not for models AZ214, AZ124, AZ64, AZ3102, AZ1502, TE214S, TE124S, TE64, GD603, GD103, GD502-DS, GD252, TE313S, TE153S, GE3102, TE3102S, GE2102, TE1502S, GE1302) $ A non-rechargeable or rechargeable battery is not included with the equipment supplied ! Use only a commercially available non-rechargeable (8+ AA/Mignon) or rechargeable battery ! When using a rechargeable battery, always use an external charger to recharge the battery Lay the balance/scale on its side Lift the compartment cover Insert the non-rechargeable (8+ AA/Mignon) or rechargeable batteries into the compartment $ Make sure to connect the positive and negative poles correctly Close the battery compartment: Press down on the cover until it clicks into place ! All used batteries are classified as waste that requires special handling (not “household” waste). Dispose of rechargeable batteries in accordance with the applicable special waste disposal regulations 5 Selecting the Line Voltage (Mains Voltage) (Optional) Use the following original AC adapters for selecting the line voltage: – AC adapter TNG8 order no. 6971951 (universal) or – AC adapter TNG8 order no. 6971952 (for the U.K.) Use the switch to toggle between 230 V and 115 V Leveling the Balance/Scale (only for models AZ…, GD…, GE3102, GE2102, GE1302, TE…-L, TE214S, TE124S, TE64, TE313S, TE153S, TE3102S, TE1502S) Level the balance/scale any time you set it up in a new location. Use only the 2 front feet of the balance/scale for leveling. Turn the 2 rear feet until they are in position (only on models GE3102, GE2102, GE1302, TE3102, TE1502) Turn the 2 front feet as shown here in the illustration until the air bubble is centered in the level indicator > In most cases, this will require several adjustment steps Anti-theft Locking Device To protect against theft, use the mounting lug on the rear panel of the balance/scale. Secure the balance/scale at the place of installation, for example with a chain or a lock 6 Operation Overview of Display and Operating Elements 11 1 2 3 10 3 Tare 9 Tare CF F 7 8 Position Designation 1 Weight units 2 Calculated-value indicator (i.e., not a weight value) 3 Taring 4 Symbol: “Printing mode active” 5 Symbol: Gross or net value 6 Data output: Press this key to send readout values to the built-in data interface. 7 Start an application program 4 5 6 Position Designation 8 Delete (Clear Function) This key is generally used to cancel functions: – Quit application program – Cancel calibration/adjustment routine | Exit the operating menu 9 On/off 10 Symbols for zero range (verified models only) 11 Weight value displayed in selected weight unit 7 Basic Weighing Function Preparation Turn on the balance/scale: Press e To change configurations: See the chapter entitled “Configuring the Balance/Scale” $ To tare the balance/scale: Press t Additional Functions: To turn off the balance/scale: Press e Warmup Time To ensure accurate results, the balance must warm up for 30 minutes before operaion. Only after this time will the balance have reached the required operating temperature. Example Basic weighing Step Key (or instruction) Display/Printout 1. Turn on the balance/scale e Self-test is performed + 52.0 2. Place container on balance/scale (here: 52 g) 3. Tare the balance/scale 4. Place sample in container on balance/scale (here: 150.2 g) 8 t + g 0.0 g + 150.2 g Calibration/Adjustment Available Features Calibration/adjustment can only be performed when – there is no load on the balance/scale, – the balance/scale is tared, – the internal signal is stable. If these conditions are not met, an error message is displayed. Otherwise, the weight required for calibration/adjustment is displayed (see “Accessories” for calibration weights). On AZ and TE models, you can use any of the following weight units to calibrate/adjust: g, kg*, lb (menu code 1. 4. x) You can block calibration/adjustment of the balance/scale: – Select menu code 1. 5. 3) Example Step Key (or instruction) Display/Printout 1. Tare the balance/scale t 2. Begin calibration Calibration weight is displayed without weight unit (here: 1000 g) t >2 sec. 3. Place the indicated calibration weight on the balance/scale After calibration, the calibration weight is displayed with wt. unit 4. Remove the calibration weight 0.0 g + 1000.0 1000.0 + 1000.0 g 0.0 g * = not on models with a readability of 0.1 mg 9 Application Programs Net-Total Formulation/Second Tare Memory With this application program you can weigh in components for formulation of a mixture. Preparation Configure the Net-Total Formulation/Second Tare Memory application in the operating menu: See “Configuring the Balance/Scale.” Menu code: 2.1.3 Example Step Key (or instruction) Display/Printout 1. Place an empty container on the balance/scale 2. Tare the balance/scale t + 0.0 g 0.0 gNET v N1 + 5. Add the next component 6. Store the 2nd component weight v 7. Add further components, if desired As described for steps 5 and 6 8. Display total weight and fill to desired final weight c 10 65.0 g + 120,5 g 3. Add the first component 4. Store the first component weight. If the print format is set to include data ID codes, the following is printed + + 120.5 g 70,5 g 0.0 gNET + 191,0 g Counting $ Reference sample quantity: Code 3. 3. 1 5 pcs Code 3. 3. 2 10 pcs (factory setting) Code 3. 3. 3 20 pcs Code 3. 3. 4 50 pcs Code 3. 3. 5 100 pcs Purpose With the Counting program you can determine the number of parts that each have approximately equal weight. Preparation Configure the Counting application in the operating menu: See “Configuring the Balance/Scale” Menu code: 2. 1. 4 $ Storage parameter (display accuracy for counting) Code 3. 4. 1 Standard resolution (factory setting) Code 3. 4. 2 With 10 times higher resolution than standard See also “Configuring the Balance/Scale” Example Determine an unknown piece count; weigh the preset reference sample quantity Menu: Application program: Counting (menu code 2. 1. 4); Reference sample quantity: 20 pcs (menu code 3. 3. 3) Step Key (or instruction) 1. Tare the balance/scale t 2. Display the reference sample quantity (here: 20 pcs) v >2 sec. 3. Place the reference sample quantity (20 pcs) on the balance/ scale (here: 66 g) 4. Start the application; if the print format is set to include data ID codes, the following piece weight is printed v 0.0 6. Display weight v 7. Display quantity v (briefly) + 66.0 g + 20 wRef + 174 + 574.2 + 174 0 8. Unload the balance/scale g ref 20 + 5. Weigh uncounted parts (here: 174 pcs) 9. Delete the reference value Display/Printout pcs 3.300 g pcs g pcs pcs c 10. Repeat the procedure starting from step 5, if desired. 11 Weighing in Percent $ Reference percentage: Code 3. 3. 1 5% Code 3. 3. 2 10 % (factory setting) Code 3. 3. 3 20 % Code 3. 3. 4 50 % Code 3. 3. 5 100 % Purpose This application program allows you to obtain weight readouts in percent which are in proportion to a reference weight. Preparation Configure the Weighing in Percent application in the operating menu: See “Configuring the Balance/Scale.” Menu code: 2. 1. 5 $ Storage parameter (display accuracy for counting) Code 3. 4. 1 Standard resolution: With stability (factory setting) Code 3. 4. 2 With 10 times higher stability than standard See also “Configuring the Balance/Scale” Example Determine an unknown percentage: store the weight on the balance/scale as a reference percentage Menu: Application program: Weighing in Percent (menu code 2. 1. 5) Menu: Reference percentage: 100 % (menu code 3. 3. 5) Step Key (or instruction) 1. Tare the balance/scale t 2. Display the reference percentage: v >2 sec. v 6. Display weight v 7. Display percentage v 8. Unload the balance/scale c 10. Repeat the procedure starting from step 5, if desired. 12 g ref100 222.5 g + 100.00 % Wxx% 5. Place an unknown weight on the balance/scale (here: 322.5 g) 9. Delete the reference percentage 0.0 + 3. Place the reference weight for 100 % on the balance/scale (here: 222.5 g) 4. Start the application; if the print format is set to include data ID codes the following is printed Display/Printout + 222.500 g + 144.94 % + 322.5 + 144.94 g 0.00 % % Weigh Averaging Purpose Use this program to determine weights under unstable ambient conditions. In this program, the balance/scale calculates the weight as the average value from a defined number of individual weighing operations. These weighing operations are also known as “subweighing operations” or “subweighs.” $ Number of subweighs for weigh averaging: 3. 3. 1 5 subweighs 3. 3. 2 10 subweighs (factory setting) 3. 3. 3 20 subweighs 3. 3. 4 50 subweighs 3. 3. 5 100 subweighs Preparation Configure the Weigh Averaging application in the operating menu: See “Configuring the Balance/Scale.” Menu code: 2. 1.12 See also “Configuring the Balance/Scale” Example Determine the weight of a sample in extremely unstable ambient conditions by calculating the average of 10 subweighing operations. Menu: Application program: Weigh Averaging (menu code 2. 1.12) Step Key (or instruction) 1. Tare the balance/scale t 2. Display the number of subweighs (here: 10) v >2 sec. 3. Place sample on the balance/scale (weight readout fluctuates) 4. Start measurement 5. Display/Printout 0.0 ref 10 g (briefly) 8888 8888 10 9 8.. . 1 v After 10 subweighs + If the print format is set to include data ID codes, the following is printed Res Unload the balance/scale + 275.5 + g G 275.5 g 275.5 g G (stable display) c 6. Delete the result 7. Repeat the procedure starting from step 3, if desired. 13 Toggle Between Weight Units With this application program you can toggle the display of a weight value back and forth between two weight units. Configure the “Toggle Weight Units” application in the operating menu: See “Configuring the Balance/Scale.” Menu code 2.1. 2 Menu code Unit 1. 7. 2 ο 1. 7. 3 1) 1. 7. 4 1. 7. 5 1. 7. 6 1. 7. 7 1. 7. 8 1. 7. 9 1. 7. 10 1. 7. 11 1. 7. 12 1. 7. 13 1. 7. 14 1. 7. 15 1. 7. 16 1. 7. 17 1. 7. 18 1. 7. 19 1. 7. 20 Grams Kilograms Carats Pounds Ounces Troy ounces Hongkong taels Singapore taels Taiwanese taels Grains Pennyweights Milligrams Parts per pound Chinese taels Mommes Austrian carats Tola Baht Mesghal 3. 1. 2 ο 3. 1. 3 1) 3. 1. 4 3. 1. 5 3. 1. 6 3. 1. 7 2) 3. 1. 8 3. 1. 9 3. 1. 10 3. 1. 11 3. 1. 12 3. 1. 13 3. 1. 14 3. 1. 15 3. 1. 16 3. 1. 17 3. 1. 18 3. 1. 19 3. 1. 20 Conversion factor 1 0.00100000000 5 0.00220462260 0.03527396200 0.03215074700 0.02671725000 0.02645544638 0.02666666000 15.43235835000 0.64301493100 1000 1.12876677120 0.02645547175 0.26670000000 5 0.08573333810 0.06578947437 0.21700000000 ο = Factory setting 1 ) = not for models with a readability of < 0.2 mg 2 ) = Factory setting only for GE models Function To toggle the display between the 1st and 2nd weight units: Press the v key 14 Abbr. on printout g kg ct lb oz ozt tlh tls tlt GN dwt mg /lb tlc mom K tol bat MS Configuring the Balance/Scale Setting the Parameters (Menu Codes) You can configure your balance/scale to meet individual requirements by selecting from the parameters available in the menu. Example: Adapt the balance/scale to unstable ambient conditions Menu code 1. 1. 4 Step Key (or instruction) Display 1. Turn off the balance/scale e 2. Turn the balance/scale back on; while all segments are displayed e t briefly 1. $ To navigate within a menu level; the last menu option is followed by the first option t repeatedly 2.· ·· 9. 1. 3. Select the 2nd menu level p 1. 1. 4. Select the 3rd menu level p 1. 1. 2 o 5. In Menu Level 3: Select the desired option t repeatedly 1. 1. 4 6. Confirm new setting; the “o” indicates the currently set option $ Select the next menu level (here: move from the 3rd to the 1st level) p >2 sec. 1. 1. 4 o p 1. $ Set other menu codes, if desired p, t 7. Store parameter settings and exit operating menu or $ Exit operating menu without storing changes t >2 sec. > Restart the application e 0.0 g 15 Balance/Scale Operating Menu (Overview) ο Factory setting √ User setting Menu l2 leve nu Me 1 1.1. Adapt filter 1.1.1 1.1.2 1.1.3 1.1.4 Minimum vibration ο Normal vibration Strong vibration Extreme vibration 1.3. Stability range 1.3.1 1.3.2 1.3.3 1.3.4 1.3.5 1/4 digit 1/2 digit 1 digit ο 2 digits 4 digits 1.4. Weight unit for calibration weight** 1.4.1 1.4.2 1.4.3 ο Grams Kilogramm1) Pounds 1.5. Calibration/adjustment 1.5.1 1.5.3 ο Accessible Blocked 1.6. Auto zero 1.6.1 1.6.2 ο On Off 1.7. Weight unit 1 See “Toggle between Weight Units” 1.8. Display accuracy 1.8.1 1.8.4 2. Application programs 2.1. Program selection See the desired application program description 3. Application parameters 3.1. Weight unit 2 3.2. Display accuracy See “Toggle between Weight Units” 3.2.1 ο Standard resolution 3.2.4 Single scale interval* see the desired application program description Balance/scale functions 3.3. Reference qty or % 3.4. Display accuracy / Weighing in Percent 5. Data interface 5.1 Baud rate * = only for GD, GE models ** = only for TE models ) = not for models with a readability of 0.1 mg 1 16 ng l3 etti leve item ry s u o t n nu Fac Me Me l1 leve nu Me ο Standard resolution Single scale interval* see the desired application program description 5.1.1 5.1.2 5.1.3 5.1.4 5.1.5 5.1.6 5.1.7 150 baud 300 baud 600 baud ο 1200 baud 2400 baud 4800 baud 9600 baud l1 leve nu Me l2 leve nu Me ng l3 etti leve item ry s u o t n nu Fac Me Me 5. Data interface 5.2 Parity 5.2.1 5.2.2 5.2.3 5.2.4 Mark Space ο Odd Even 5.3 No. of stop bits 5.3.1 5.3.2 ο 1 stop bit 2 stop bits 5.4 Handshake mode 5.4.1 5.4.2 Software Hardware 2 char. after CTS ο Software 1 char. after CTS 5.4.3 5.5 Communications mode 5.5.1 5.5.2 ο SBI (ASCII) GLP record 6. Print for weighing 6.1 Manual/auto print mode 6.1.1 6.1.2 6.1.3 6.1.4 Manual without stability ο Manual at stability Automatic without stability Automatic at stability 7. Print with applications programs 7.1 Line format of printout 7.1.1 7.1.2 Without data ID Codes ο With data ID Codes 7.2 ISO/GLP-compliant printout 7.2.1 7.2.2 7.2.3 ο Off For calibration/ adjustment only Always on 7.3 Printout time 7.3.1 7.3.2 ο 24-h format 12-h format 8.1. Menu 8.1.1 8.1.2 ο Parameter settings alterable Parameter settings read only 8.2. External switch function 8.2.1 8.2.4 8.2.5 8.2.6 8.2.8 c key t key ο p key v key t key 8.3. Power-on mode for balance/scale 8.3.1 Off/on (battery shuts off automatically after 3 min) ο Stand-by/on 9.– 9.– 1 9.– 2 8. Extra functions 8.3.2 9. Menu-Reset Factory setting Reset menu Do not reset 17 ISO/GLP-compliant Printout Features You can have the parameters pertaining to the ambient weighing conditions printed before (GLP header) and after (GLP footer) the values of a weighing series. These parameters include: – – – – – – – GLP header: Date Time at beginning of measurement Balance/scale manufacturer Balance/scale model Balance/scale serial number Software version number Identification number of the current sampling operation GLP footer: – Date – Time at end of measurement – Field for operator signature ! The record can only be output to a Sartorius data printer YDP20-0CE. Settings Set the following menu codes (see “Configuring the Balance/Scale”): – GLP-compliant record: menu code 5 5 2 – ISO/GLP-compliant record after calibration/adjustment only: menu code 7 2 2 or ISO/GLP-compliant record always on: menu code 7 2 3 – Line format for printout: With data ID codes – 22 characters: menu code 7 1 2 – Printout date/time: – 24-h format: menu code 7 3 1 – 12-h format: menu code 7 3 2 ! No ISO/GLP-compliant record is output if any of the following settings are configured: menu codes 6 1 3, 6 1 4 (automatic printout) and 7 1 1 Function Keys Press p to output header and first measured value. > Header is output the first time p is pressed To output header and reference data automatically with an application program active: Press v End application program: End application program and output GLP footer: Press c 18 The ISO/GLP-compliant record can contain the following lines: -------------------17-Jan-2003 10:15 SARTORIUS AG Mod. TE6100 Ser. no. 10105355 Ver. no. 00-19-41 ID -------------------L ID wRef + 21.14 g Qnt + 235 pcs Qnt + 567 pcs -------------------17-Jan-2003 10:20 Name: -------------------- Dotted line Date/time (beginning of measurement) Balance/scale manufacturer Balance/scale model Balance/scale serial number Software version ID Dotted line Measurement series no. Counting: Reference weight Counting result Counting result Dotted line Date/time (end of measurement) Field for operator signature Blank line Dotted line ISO/GLP-compliant printout for external calibration/adjustment -------------------17-Jan-2003 10:30 SARTORIUS AG Mod. TE6100 Ser. no. 10105355 Ver. no. 00-19-41 ID -------------------Cal. Extern Set + 5000.0 g -------------------17-Jan-2003 10:32 Name: -------------------- Dotted line Date/time (beginning of measurement) Balance/scale manufacturer Balance/scale model Balance/scale serial number Software version ID Dotted line Calibration/adjustment mode Calibration weight Dotted line Date/time (end of measurement) Field for operator signature Blank line Dotted line 19 Data Interface Purpose Your balance/scale comes equipped with an interface port for connection to a computer or other peripheral device. You can use an on-line computer to change, start and/or monitor the functions of the balance/scale and the application programs. Female interface connector 25 13 14 1 Pin Assignment Chart, 25-pin female interface connector, RS-232: Pin 1: Shield Pin 2: Data output (TxD) Pin 3: Data input (RxD) Pin 4: Internal ground (GND) Pin 5: Clear to Send (CTS) Pin 6: Not connected Pin 7: Internal ground (GND) Pin 8: Internal ground (GND) Pin 9: Not connected Pin 10: Not connected Pin 11: Charging voltage for rechargeable battery pack +12 … +20 V ( I _ out 25mA) Pin 12: Reset _ Out *) Pin 13: +5 V output Pin 14: Internal ground (GND) Pin 15: Universal remote switch Pin 16: Not connected Pin 17: Not connected Pin 18: Not connected Pin 19: Not connected Pin 20: Data Terminal Ready (DTR) Pin 21: Internal ground (GND) Pin 22: Not connected Pin 23: Not connected Pin 24: Not connected Pin 25: +5 V output *) = Hardware restart 20 Preparation You can set these parameters for other devices in the Setup menu (see the chapter entitled “Configuring the Balance/Scale”). You will also find a detailed description of the available data interface commands in the file “Data Interface Descriptions for AZ, GD, GE and TE Models”, which you can download from the Sartorius website (www.sartorius.com “Download Center”). The many and versatile properties of these balances/scales can be fully utilized for printing out records of the results when you connect your balance/scale to a Sartorius data printer. The recording capability for printouts makes it easy for you to work in compliance with ISO/GLP. For remote switch Error Codes Error codes are shown on the main display for 2 seconds. The program then returns automatically to the previous mode (e.g., weighing). Display No segments appear on the display Cause No AC power is available The AC adapter is not plugged in Battery or rechargeable battery pack is discharged Solution Check the AC power supply Plug in the AC adapter Replace the battery or recharge the battery pack using an external charger Unload the balance/scale The load exceeds the balance/scale capacity l and E 54 The weighing pan is not in place Place the weighing pan on the balance/scale Something is touching Move that object that the weighing pan is touching the weighing pan e 02 Calibration parameter Unload the balance/scale Press t to tare the balance/scale not met, e.g.: – balance/scale not zeroed Calibrate only when zero – balance/scale is loaded is displayed e 09 When gross value < zero; no tare Tare the balance/scale e 10 The t key is blocked when Press c to clear the tare there is data in the second tare memory and release the tare key memory (net-total). Only 1 tare function can be used at a time e 11 Value input is not allowed for Press t second tare memory e 22 Weight is too light or there is Increase the weight on no sample on the balance/scale the balance/scale e 30 Interface port for Contact your local printer output is blocked Sartorius Service Center Max. weighing capacity The balance/scale was Place the weighing pan on the is less than indicated turned on without the balance/scale and press e under “Specifications” weighing pan in place to turn the balance/scale back on The weight readout The balance/scale has not been Calibrate/adjust the balance/scale is obviously wrong calibrated/adjusted The balance/scale was not Tare the balance/scale tared before weighing h If any other errors occur, contact your local Sartorius Service Center! 21 Care and Maintenance Service Regular servicing by a Sartorius technician will extend the service life of your balance/scale and ensure its continued weighing accuracy. Sartorius can offer you service contracts, with your choice of regular maintenance intervals ranging from 1 month to 2 years. The optimum maintenance interval depends on the operating conditions at the place of installation and on the individual tolerance requirements. Repairs Repair work must be performed by trained service technicians. Any attempt by untrained persons to perform repairs may lead to hazards for the user. Cleaning Unplug the AC adapter from the wall outlet (mains supply). If you have an interface cable connected to the balance/scale port, unplug it from the port, Clean the balance/scale using a piece of cloth which has been wet with a mild detergent (soap) After cleaning, wipe down the balance/scale with a soft, dry cloth. Removing and Cleaning the Weighing Pan: Lift up and remove the weighing pan together with the pan support by gripping them from under the shield ring. Make sure that you do not damage the weighing system in doing so. !Make sure that no liquid enters the balance/scale housing. !Do not use any aggressive cleaning agents (solvents or similar agents). 22 Cleaning Stainless Steel Surfaces Clean all stainless steel parts regularly. Remove the stainless steel weighing pan and thoroughly clean it separately. Use a damp cloth or sponge to clean any stainless steel parts on the balance/scale. Only use commercially available household cleaning agent that is suitable for use on stainless steel. Clean stainless steel surfaces by wiping them down. Then rinse thoroughly, making sure to remove all residues. Afterwards, allow the balance/scale to dry. If desired, you can apply oil to the cleaned surfaces as additional protection. Solvents are permitted for use only on stainless steel parts. Safety Inspection If there is any indication that safe operation of the balance/scale with the AC adapter is no longer warranted: Turn off the power and disconnect the equipment from AC power immediately > Lock the equipment in a secure place to ensure that it cannot be used for the time being In this case, notify your nearest Sartorius Service Center or the International Technical Support Unit based in Goettingen, Germany. Maintenance and repair work may only be performed by service technicians who are authorized by Sartorius. Instructions for Recycling To ensure adequate protection for safe shipment, your balance/scale has been packaged to the extent necessary using environmentally friendly materials. After successful installation of the balance/scale, you should return this packaging for recycling because it is a valuable source of secondary raw material. For information on recycling options, including recycling of old weighing equipment, contact your municipal waste disposal center or local recycling depot. 23 Overview Specifications Talent Series Model Weighing capacity Readability Tare range (subtractive) Repeatability Linearity Operating temperature range Allowable ambient operating temperature Sensitivity drift within +10…+30 °C (50°F–86°F) Response time (average) Adaptation to ambient conditions Display update (depends on the filter level selected) External calibration weight (of at least accuracy class) Net weight, approx. Pan size Weighing chamber height Dimensions (WxDxH) AC power source/ power requirements Frequency AC power source, direct current Power consumption (average) Hours of operation with the YRB08Z rechargeable battery pack 24 g mg g <±mg <±mg TE214S TE124S 210 120 0.1 0.1 210 120 0.1 0.1 0.2 0.2 +10…+30 °C (50°F to 86°F) TE64 60 0.1 60 0.1 0.2 +5…+40°C (41°F to 104°F) >±/K s 2 · 10–6 2 ·10–6 2 ·10–6 3 3 3 By selection of 1 of 4 optimized filter levels s g lb kg mm mm mm 0.2–0.4 200 (E2) 0.4 3.2 90 d 200 200+ 270+299 0.2–0.4 100 (E2) 0.2 3.2 90 d 200 0.2–0.4 50 (E2) 0.1 3.2 90 d 200 AC adapter 230 V or 115 V, +15% to –20% 48–60 Hz V W 10–20 1 1 1 h 20 20 20 Gem Series Model GD603 Weighing capacity Readability Tare range (subtractive) Repeatability <± Linearity <± Operating temperature range Allowable ambient operating temperature Sensitivity drift within +10…+30 °C <±/K Response time (average) s Adaptation to ambient conditions Display update (depends on the filter level selected) s External calibration weight g (of at least accuracy class) Net weight, approx. kg Pan size mm Weighing chamber height mm Dimensions (B+T+H) mm 605 ct/121 g 185 ct/37 g 0.001 ct/0.2 mg 0.001 ct/0.2 mg 605 ct/121 g 185 ct/37 g 0.001 ct/0.2 mg 0.001 ct/0.2 mg 0.002 ct/0.4 mg 0.002 ct/0.4 mg +10…+30 °C (50°F to 86°F) AC power source/ power requirements Frequency AC power source/ direct current V Power consumption (average) W Hours of operation with the YRB08Z rechargeable battery pack h GD103 GD502-DS 505 ct/101 g 0.005 ct 505 ct/101 g 0.0075 ct 0.015 ct GD252, GD252-DS 255 ct/51 g 0.005 ct 255 ct/51 g 0.0075 ct 0.015 ct +5.… +40°C (41°F to 104°F) 2 ·10–6 2 ·10–6 4·10–6 3 3 2,5 By selection of 1 of 4 optimized filter levels 4·10–6 2,5 0.2–0.4 100 (F1) 0.2–0.4 20 (F1) 0.2–0.8 50 (F1) 0.2–0.8 50 (F1) 3.0 90 d 133 200+270+233 3.0 90 d 133 200+270+233 1.7/2.7 100 d 133 200+270+233 1.7/2.7 100 d GD252-DS: 133 200+270+120/ 200+270+233 AC adapter 230 V or 115 V, +15% to –20% 48–60 Hz 10–20 1 1 0.75 0.75 20 20 25 25 25 Talent and Gold Series Model Weighing capacity Readability Tare range (subtractive) Repeatability Linearity Operating temperature range Allowable ambient operating temperature Sensitivity drift within +10…+30 °C Response time (average) Adaptation to ambient conditions Display update (depends on the filter level selected) External calibration weight (of at least accuracy class) Net weight, approx. Pan size Dimensions (B+T+ H) AC power source/ power requirements Frequency AC power source/ direct current Power consumption (average) Hours of operation with the YRB08Z rechargeable battery pack * = only for TE models 26 g g g <±g <±g TE313S, TE153S, TE313S-DS TE153S-DS 310 150 0.001 0.001 310 150 0.001 0.0015 0.002 0.003 +10…+30 °C (50° to 86°F) TE3102S, GE3102 3,100 0.01 3,100 0.01 0.02 GE2102 2,100 0.01 2,100 0.015 0.04 3·10–6 2.5 4·10–6 2.5 +5… +40°C (41°F to 104°F) <± /K s 4·10–6 3 4·10–6 2.5 By selection of 1 of 4 optimized filter levels s g lb* kg mm mm 0.2–0.8 200 (E2) 0.4 2.2/3.2 100 d 200+270+120/ TE…-DS: 200+270+299 100 (F1) 0.2 1.7/2.7 100 d 2000 (E2) 4 2.2 174+143 200+270+70 2000 (F1) – 1.7 174+143 AC adapter 230 V or 115 V, +15% to –20% 48–60 Hz V 10–20 W 0.75 h 20 25 20 20 Talent and Gold Series Model Weighing capacity Readability Tare range (subtractive) Repeatability Linearity Operating temperature range Allowable ambient operating temperature Sensitivity drift within +10…+30 °C Response time (average) Adaptation to ambient conditions Display update (depends on the filter level selected) External calibration weight (of at least accuracy class) Net weight, approx. Pan size Dimensions (B+T+H) AC power source/ power requirements Frequency AC power source/ direct current Power consumption (average) Hours of operation with – Mignon, AA alkaline manganese battery, approx. – fully charged rechargeable 1000 mAh battery, approx. Hours of operation with the YRB08Z rechargeable battery pack TE1502S g g g <±g <±g GE1302 1,500 1,300 0.01 0.01 1,500 1,300 0.015 0.015 0.03 0.03 +10…+30 °C (50° to 86°F) GE812 810 0.01 810 0.01 0.02 GE612, TE612, TE612-L 610 0.01 610 0.01 0.02 5·10–6 2 5·10–6 2 +5…+40°C (41°F to 104°F) <± /K s 4·10–6 2.5 4·10–6 2.5 By selection of 1 of 4 optimized filter levels s g lb* kg mm mm 0.2–0.8 1,000 (F1) 2 1.7 174 +143 200+270+ 70 1,000 (F1) – 1.7 174 + 143 500 (F2) – 1.4 116 d 500 (F2) 1 1.4 116 d AC adapter 230 V or 115 V, +15% to –20% 48–60 Hz V 10–20 W 0.75 h – – 50 50 h – – 20 20 h 25 25 25 25 * = only for TE models 27 Talent and Gold Series Model Weighing capacity Readability Tare range (subtractive) Repeatability Linearity Operating temperature range Allowable ambient operating temperature Sensitivity drift within +10…+30 °C Response time (average) Adaptation to ambient conditions Display update (depends on the filter level selected) External calibration weight (of at least accuracy class) Net weight, approx. Pan size Dimensions (B+T+H) AC power source/ power requirements Frequency AC power source/ direct current Power consumption (average) Hours of operation with – Mignon, AA alkaline manganese battery, approx. – fully charged rechargeable 1000 mAh battery, approx. Hours of operation with the YRB08Z rechargeable battery pack * = only for TE models 28 g g g <±g <±g GE412, TE412, GE212, TE212, TE412-L TE212-L 410 210 0.01 0.01 410 210 0.01 0.01 0.02 0.02 +10… +30°C (50° to 86°F) GE7101 7,100 0.1 7,100 0.1 0.2 TE6101, TE6101-L 6,100 0.1 6,100 0.1 0.2 0.5 ·10–5 2 0.5 ·10–5 2 +5… +40°C (41°F to 104°F) <± /K s 0.5 ·10–5 2 1 ·10–5 2 By selection of 1 of 4 optimized filter levels s g lb* kg mm mm 0.2–0.8 200 (F2) 0.4 1.4 116 d 200+270+70 100 (M1) 0.2 1.4 116 d 5000 (F2) – 1.7 174+143 AC adapter 230 V or 115 V, +15% to –20% 48–60 Hz V 10–20 W 0.75 h 50 h 20 h 25 5000 (F2) 10 1.7 174+143 Talent and Gold Series Model Weighing capacity Readability Tare range (subtractive) Repeatability Linearity Operating temperature range Allowable ambient operating temperature Sensitivity drift within +10…+30 °C Response time (average) Adaptation to ambient conditions Display update (depends on the filter level selected) External calibration weight (of at least accuracy class) Net weight, approx. Pan size Dimensions (B+T+H) AC power source/, power requirements Frequency AC power source/direct current Power consumption (average) Hours of operation with – Mignon, AA alkaline manganese battery, approx. – fully charged rechargeable 1000 mAh battery, approx. Hours of operation with the YRB08Z rechargeable battery pack g g g <±g <±g GE4101, GE2101, GE811 TE4101, TE2101, …-L …-L 4,100 2,100 810 0.1 0.1 0.1 4,100 2,100 810 0.1 0.1 0.1 0.2 0.2 0.2 +10…+30°C (50°F to 86°F) TE601, TE12000, TE6100, TE4100, …-L …-L …-L …-L 610 0.1 610 0.1 0.2 12,000 1 12,000 1 2 6,100 1 6,100 1 2 4,100 1 4,100 1 2 5·10–5 2.5·10–5 5·10–5 1.5 1.5 1.5 5·10–5 1.5 +5.… +40°C (41°F to 104°F) <±/K 1·10–5 s 2 2·10–5 1.5 5·10–5 1.5 By selection of 1 of 4 optimized filter levels s kg lb* kg mm mm 0.2–0.8 2 (F2) 1 (M1) 4 2 1.7 174+143 200+270+70 V W AC adapter 230 V or 115 V, +15% to –20% 48–60 Hz 10–20 0.75 h 50 h 20 h 25 0.5 (M1) 0.5 (M1) 5 (M1) 1 1 10 5 (M1) 10 2 (M1) 4 * = only for TE models 29 Specifications M-power Series Model Weighing capacity Readability Tare range (subtractive) Repeatability Linearity Operating temperature range Allowable ambient operating temperature Sensitivity drift within +10…+30 °C (50°F–86°F) Response time (average) Adaptation to ambient conditions Display update (depends on the filter level selected) External calibration weight (of at least accuracy class) Net weight, approx. Pan size Weighing chamber height Dimensions (WxDxH) AC power source/ power requirements Frequency AC power source, direct current Power consumption (average) Hours of operation with the YRB08Z rechargeable battery pack 30 g mg g <±mg <±mg AZ214 AZ124 210 120 0.1 0.1 210 120 0.2 0.2 0.3 0.3 +10…+30 °C (50°F to 86°F) AZ64 60 0.1 60 0.2 0.3 +5…+40°C (41°F to 104°F) >±/K s 2 · 10–6 2 ·10–6 2 ·10–6 3 3 3 By selection of 1 of 4 optimized filter levels s g lb kg mm mm mm 0.2–0.4 200 (E2) 0.4 3.2 90 d 200 200+ 270+299 0.2–0.4 100 (E2) 0.2 3.2 90 d 200 0.2–0.4 50 (E2) 0.1 3.2 90 d 200 AC adapter 230 V or 115 V, +15% to –20% 48–60 Hz V W 10–20 1 1 1 h 20 20 20 M-power Series Model Weighing capacity Readability Tare range (subtractive) Repeatability Linearity Operating temperature range Allowable ambient operating temperature Sensitivity drift within +10…+30 °C Response time (average) Adaptation to ambient conditions Display update (depends on the filter level selected) External calibration weight (of at least accuracy class) Net weight, approx. Pan size Dimensions (B+T+H) AC power source/ power requirements Frequency AC power source/ direct current Power consumption (average) Hours of operation with – Mignon, AA alkaline manganese battery, approx. – fully charged rechargeable 1000 mAh battery, approx. Hours of operation with the YRB08Z rechargeable battery pack g g g <±g <±g AZ313 AZ153 310 150 0.001 0.001 310 150 0.003 0.003 0.004 0.004 +10…+30 °C (50° to 86°F) AZ3102 3,100 0.01 3,100 0.015 0.03 AZ1502 1,500 0.01 1,500 0.015 0.03 AZ612 610 0.01 610 0.015 0.03 3 · 10–6 2.5 4 · 10–6 2.5 5 · 10–6 2.5 +5… +40°C (41°F to 104°F) <±/K s 4 · 10–6 3 4 · 10–6 3 By selection of 1 of 4 optimized filter levels s g lb kg mm mm 0.2–0.8 200 (E2) 100 (F1) 0.4 0.2 2.2 1.7 100 d 100 d 200+270+120 2000 (E2) 1,000 (F1) 4 2 2.2 1.7 174+143 174+143 200+270+70 500 (F2) 1 1.4 116 d AC adapter 230 V or 115 V, +15% to –20% 48–60 Hz V 10–20 W 0.75 h – – – – 50 h – – – – 20 h 20 25 20 25 25 31 M-power Series Model Weighing capacity Readability Tare range (subtractive) Repeatability Linearity Operating temperature range Allowable ambient operating temperature Sensitivity drift within +10…+30 °C Response time (average) Adaptation to ambient conditions Display update (depends on the filter level selected) External calibration weight (of at least accuracy class) Net weight, approx. Pan size Dimensions (B+T+H) AC power source/ power requirements Frequency AC power source/ direct current Power consumption (average) Hours of operation with – Mignon, AA alkaline manganese battery, approx. – fully charged rechargeable 1000 mAh battery, approx. Hours of operation with the YRB08Z rechargeable battery pack 32 g g g <±g <±g AZ212 AZ6101 210 6,100 0.01 0.1 210 6,100 0.015 0.1 0.03 0.3 +10… +30°C (50° to 86°F) AZ4101 4,100 0.1 4,100 0.1 0.3 AZ2101 2,100 0.1 2,100 0.1 0.3 AZ601 610 0.1 610 0.1 0.3 1·10–5 2 2·10–5 2 5·10–5 1.5 +5… +40°C (41°F to 104°F) <±/K 1· 10–5 s 2.5 0,5 ·10–5 2 By selection of 1 of 4 optimized filter levels s g lb kg mm mm 0.2–0.8 100 (M1) 5000 (F2) 0.2 10 1.4 1.7 116 d 174 + 143 200 +270 +70 2 (F2) 4 1.7 174 + 143 1 (M1) 2 1.7 174 + 143 AC adapter 230 V or 115 V, +15% to –20% 48–60 Hz V 10–20 W 0.75 h 50 h 20 h 25 0.5 (M1) 1 1.7 174 + 143 Accessories (Options) Product Data printer with date/time, statistics evaluation, transaction counter functions and LCD Order No. YDP20-0CE – Paper (5 rolls) 6906937 Remote display – reflective – for overhead projectors, transmissive YRD02Z YRD13Z External rechargeable battery pack with external battery charger (hours of operation: 20 or 40, depending on balance/scale model) SartoConnect data transfer program for interfacing a Sartorius balance to a PC with a Windows 95/98 or NT operating system This software enables you to transfer the data recorded by your balance to any PC application program (e.g., Excel). YRB08Z YSC01L RS-232C interface cable for PC connection, 25-pin COM data interface for PC connection, 9-pin 7357312 7357314 Universal remote control switch: Foot switch with T-connector Hand switch with T-connector YFS01 YHS02 T-connector for connecting 2 peripheral devices Carrying case – for models with a readability >1 mg YTC01 YDB01TE 33 Product In-use dust cover – Only over operating elements for models GD…, AZ214, AZ124, AZ64, TE214S, TE124S, TE64, TE…-DS – for models with a rectangular weighing pan – for models with a round weighing pan Order No. 6960TE01 6960TE03 6960TE02 Attaching the in-use dust cover to models with a glass draft shield: – Remove adhesive strip from balance/scale housing – Place dust cover on balance/scale – Stick adhesive strip on dust cover – – – – – – – – – – – – – – – – – – – – – – – – 34 Weighing bowls/scoops/gem trays 300 ml, weight 86 g, stainless steel 1000 ml, weight 240 g, stainless steel 300 ml, weight 22 g, aluminum 110 ml, 90 mm d, aluminum 270 ml, weight 62 g, 137 mm d, stainless steel 62 mm d, stainless steel 85 ml, 70 mm d, aluminum 180 ml, 90 mm d, aluminum 174 mm d, stainless steel Calibration weights for AZ3102, TE 3102S (2000 g; E2) for AZ313, AZ214, TE313S, TE214S (200 g, E2) for AZ124, TE124S (100 g, E2) for AZ64, TE64 (50 g, E2) for GD103 (20 g, F1) for GD252 (50 g, F1) for AZ153, GD603, TE153S (100 g, F1) for AZ1502, TE1502S, GE1302, GE4101, for GE2102 (2000 g, F1) TE4101, (1 kg, F1) for AZ612, GE812, GE612, GE811, TE601 (500 g, F2) for GE412, TE412 (200 g, F2) for AZ212, GE212, TE212 (100 g, F2) for AZ4101, TE4100 (2000 g, F2) for AZ2101, GE2101, TE2101 (1 kg, F2) for AZ6101, GE7101, TE6101, TE12000, TE6100 (5 kg, F2) or alternative (5 kg; ± 0.25 mg) 6407 641211 69641304 69GP0003 YWP03G 6910848 YWP06G YWP05G YWP04G YCW6228-00 YCW5228-00 YCW5128-00 YCW4528-00 YCW4238-00 YCW4538-00 YCW5138-00 YCW6238-00 YCW6138-00 YCW5548-00 YCW5248-00 YCW5148-00 YCW6248-00 YCW6148-00 YCW6548-00 YSS653-00 35 36 Sartorius AG Weender Landstrasse 94–108 37075 Goettingen, Germany Phone +49.551.308.0 Fax +49.551.308.3289 www.sartorius-mechatronics.com Copyright by Sartorius AG, Goettingen, Germany. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius AG. The status of the information, specifications and illustrations in this manual is indicated by the date given below. Sartorius AG reserves the right to make changes to the technology, features, specifications and design of the equipment without notice. Status: September 2010, Sartorius AG, Goettingen, Germany Printed in Germany on paper that has been bleached without any use of chlorine W1A000 · KT Publication No.: WTE6001-e10096 ">
Download
Advertisement
Key features
Basic weighing function
Net-Total Formulation/Second Tare Memory
Counting
Weighing in Percent
Weigh Averaging
Toggle Between Weight Units
Calibration/Adjustment
ISO/GLP-compliant Printout
Data Interface
Error Codes
Frequently asked questions
The maximum weighing capacity of the Talent TE214S is 210 g.
The Talent TE214S can be used with a commercially available non-rechargeable or rechargeable battery: 8+ AA, Mignon.
The Talent TE214S can operate for 20 hours on a fully charged YRB08Z rechargeable battery pack.
The ambient operating temperature range for the Talent TE214S is +10…+30 °C (50°F to 86°F). The ambient operating temperature range for the Gem GD603 is +10…+30 °C (50°F to 86°F).
The Talent TE214S requires an external calibration weight of at least accuracy class E2. The Gem GD603 requires an external calibration weight of at least accuracy class F1.