- Computers & electronics
- Audio & home theatre
- TV set-top boxes
- Satellite antennas
- Advantech
- TV Antenna 120
- Assembly Instructions
advertisement
▼
Scroll to page 2
of 14
INTREPID120TM – Assembly Instructions INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Website www.AdvantechAMT.com Page 1 of 14 Ref: PM-INT120-002-11023 The INTREPID120 Antenna System The ‘INTREPID’ class of antenna systems are renowned for their compact size, light weight and powerful performance having been designed to excel in today’s ever demanding satellite communications industry. The user friendly modular design allows for simple, fast and accurate satellite acquisition either as a manually controlled mount or as a fully auto-acquisition motorised mount. The clever design of the tri-pod mount also means that other 3rd party antennas can be fitted allowing existing equipment to be cost effectively upgraded. The main reflector is manufactured from high quality carbon fibre and is supplied in six easily assembled petals that employ a revolutionary spherical dowel locking mechanism. The revolutionary design of the complete fly-away system allows for the INTREPID class antenna to be transported in easily manageable carry cases weighing less than 32kg that can be checked onto any commercial aircraft making the INTREPID class antenna a totally flexible fly-away system. INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Website www.AdvantechAMT.com Page 2 of 14 Ref: PM-INT120-002-11023 Contents 1.0 Case Contents 2.0 Assembly Instructions INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Website www.AdvantechAMT.com Page 3 of 14 Ref: PM-INT120-002-11023 1.0 Case Contents 1.1 Case 1 - Tripod Case Tripod Base Extension Legs 1.2 Case 2 – Elevation & Feed arm Case Elevation head Extension arm OMT Assembly INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Website www.AdvantechAMT.com Page 4 of 14 Ref: PM-INT120-002-11023 The Tripod is transported in its custom built transit case. The components are secured in place by the lid of the case and are supported as shown. 1.3 Case 3 - Antenna Case Antenna Stays Antenna Bag Remove the Antenna stays & lift out the antenna bag containing the carbon antenna. INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Website www.AdvantechAMT.com Page 5 of 14 Ref: PM-INT120-002-11023 2.0 Assembly Instructions 2.1 Tripod Assembly Remove the tripod base from the packing case. INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Website www.AdvantechAMT.com Page 6 of 14 Ref: PM-INT120-002-11023 Invert and Place Tri-pod base securely. Splay the Tri-pod legs and force the centre lock into the stow position. Remove the tripod extension legs and locate into tripod head. Tighten and lock leg cams. INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Website www.AdvantechAMT.com Page 7 of 14 Ref: PM-INT120-002-11023 Stand tripod on legs and level using adjustable levelling feet and bubble level mounted on the tripod base. Remove the elevation head from the packing case. INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Website www.AdvantechAMT.com Page 8 of 14 Ref: PM-INT120-002-11023 Assemble elevation head onto the rear locations on the tripod base and lock with Vee-Lock handle by pushing in an upward motion. RF Location points Antenna Clamp Inclinometer RF Location points Elevation Adjustment Azimuth Adjustment Azimuth Brake The tripod is ready to accept the antenna. INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Website www.AdvantechAMT.com Page 9 of 14 Ref: PM-INT120-002-11023 2.2 Antenna Assembly Remove antenna base petal, antenna carry case and stays. Locate and lock antenna base petal onto tripod head. INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Page 10 of 14 Website www.AdvantechAMT.com Ref: PM-INT120-002-11023 Secure and lock bottom petal into position on tripod base petal using over centre locking clips. INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Page 11 of 14 Website www.AdvantechAMT.com Ref: PM-INT120-002-11023 Tripod with 1st and 2nd petal attached. Assemble left and right sides of the antenna. INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Page 12 of 14 Website www.AdvantechAMT.com Ref: PM-INT120-002-11023 Lock right and left sides of the antenna to the tripod antenna assembly. 2.3 Feed Arm Assembly Remove OMT assembly and extension arm. Remove Quick-Connect™ dust caps INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Page 13 of 14 Website www.AdvantechAMT.com Ref: PM-INT120-002-11023 Lock both parts of the feed arm together with feed arm cam. Make the QuickConnect™ connections. Lock the feed arm into tripod assembly using the secure cam lock. Attach feed arm stays into position, one on each side. Attach flexible waveguide from feed arm to elevation head & from elevation head to HPA. INTREPID120 UK Office Phone +44 1480 357 600 Fax +44 1480 357 601 US Office Phone +1 480 839 4136 Fax +1 480 839 0860 Canada Office Phone +1 514 420 0045 Fax +1 514 420 0073 E-mail [email protected] Page 14 of 14 Website www.AdvantechAMT.com Ref: PM-INT120-002-11023
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement