Kompernass Blood Pressure Monitor KH 8099 User manual

Add to My manuals
10 Pages

advertisement

Kompernass Blood Pressure Monitor KH 8099 User Manual | Manualzz
 Contents
01... Blood Pressure Monitor Intended Use
02....... 1. What is blood pressure ?
02....... 2. Why is it useful measure blood pressure
at home ?
rere A. WHO blood pressure classifications
TT B. Variations in blood pressure
04....... 3. Important information before use of
the unit
06....... 4. Device description
errr A. Name of the parts
panacaa es B. Description of display symbols
08....... 5. Changing Batteries
08....... 6. Attaching pressure cuff
09....... 7. Correct measurement position
С
ontent
8. Description of display marks.
9. How to measure.
A. Inserting batteries in position.
B. Setting date and time.
D. Storing recalling and erasing measurement
data.
E. To change batteries.
14....... 10. Maintenance.
14....... 11. Safe-keeping.
14....... 1 2. To prevent malfunction.
15....... 13. Warning.
16....... 14. Specifications.
17....... Note
C. Steps to take blood pressure measurement.
Blood Pressure Monitor Intended Use:
Measures human beings Systolic, Diastolic blood pressure and
heart rate using the oscillometric method. All values can be read
out in one LCD DISPLAY. Measurement position is on adult wrist
only.
Having one's blood pressure measured by a doctor in a hospital
tends to stimulate nervousness in the person and may even
create high blood pressure. Blood pressure in accordance with
variety of conditions varies. So judgment is not possible on the
basis of a single measurement.
It is better to take measurement at home. Regular home
monitoring will let you have a record of your measurements. This
information may provide a better reference of what your blood
pressure really is, and may help your doctor make important
decisions about your diagnosis and treatment.
If end-user has one of the diseases as heart troubles, Kidney
trouble or diabetes or Frustration problem of Blood vessel,
please consult a doctor before using the devices.
1. What is blood pressure ?
Blood pressure is a measurement of the force of blood flowing
against the walls of the arteries. Arterial blood pressure is
constantly changing during the course of the cardiac cycle. The
highest pressure in the cycle is called the systolic blood pressure,
the lowest is the diastolic blood pressure. Both pressure readings,
the systolic and the diastolic are necessary to enable a physician
to evaluate the status of a patient's blood pressure. Many factors
such as physical activity, anxiety or the time of day, can influence
your blood pressure. Blood pressure is typically low in the
morning and increases from the afternoon to the evening. It is
lower in the summer and higher in the winter.
2. Why is it useful to measure blood pressure
at home ?
Having one's blood pressure measured by a doctor in a hospital
or a clinic, and a group health checks, tend to stimulate
nervousness in the subject and may even create high blood
pressure. Also varies blood pressure in accordance with a
variety of conditions and so judgment is not possible on the
basis of a single measurement.
The blood pressure measured first thing in the morning after
getting up, before taking any food and with the subject still, is
known as the fundamental blood pressure. In practice it is rather
difficult to record the fundamental blood pressure, but to come
2
as near as possible to measuring the blood pressure in an
environment that is close to this, is why it is useful to take the
measurement at home.
A. WHO blood pressure classifications
Standards for assessment
of high or low blood
pressure without regard to
age, have been established
by the World Health
Organization (WHO),
as shown in the chart.
3
3
TI
o
HYPERTENSION
©
©
HIGH NORMAL
NORMAL
130 139 mmHg
Systolic Blood Pressure
Diastolic Blood Pressure
Ol
* Figure No.1
B. Variations in blood pressure
Individual blood pressures vary greatly both on a daily and a
seasonal basis. These variations are even more pronounced in
hypertense patients. Normally the blood pressure rises while
at work and is at its lowest during sleeping period.
(hypertense: means a person who has high blood pressure
symptom.)
160
The graph below illustrated | 1 © в
the variations in blood po
pressure over a whole day |; «
with measurement taken 7 ©
every five minutes.
a
— 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 45 67 8 91011
Time
* Figure No.2
The thick line represents sleep. The rise in blood pressure at 4 PM
(Ain the graph) and 12 PM (B in the graph) correspond to an
attack of pain.
3. Important information before use of the unit
©
©
The device comply with EMC requirements according to
IEC60601-1-2,
Radio transmitting equipment, cellular phones etc. Shall not be
used in the close proximity of the device since this could
influence the performance of the device.
Particular precaution must be considered during use of strong
emission sources such as High Frequency surgical equipment
and similar so that e.g. The HF-cables are not routed on or
near the device. If in doubt, contact qualified technician or your
local representative.
Blood pressure measurements should be interpreted by a
physician or trained health professional who is familiar with your
medical history. By using the unit regularly and recording the
results for your physician to interpret, you keep your physician
informed of the continuing trends in your blood pressure.
Wind the cuff snugly around your wrist and the cuff must be at
the same level as your heart.
Do not vibrate the unit during measurement, or the proper
measurement will not be achieved.
4
© Perform measurement quietly in a relaxed position.
O Do not wind the cuff over jacket or sweater sleeve, or
measurement cannot be done.
© Keep in mind, that blood pressure naturally varies from time
to time through out the day and also is affected by lots of
different factors such as smoking, alcohol consumption,
medicamentation and physical activity.
O People with a condition that causes circulatory problems
(diabetes, kidney disease, arteriosclerosis or poor peripheral
circulation) may get lower readings with this monitor that with
a blood pressure monitor that is used on the upper arm.
Please consult your physician to determine if your wrist blood
pressure accurately reflects your actual blood pressure.
O Blood pressure measurement determine with the unit are
equivalent to those obtained by a trained observer using the
cuff / stethoscope auscultation method. Within the limits
prescribed by the American National Standard for Electronic
or Automated Sphygmomanometers.
4. Device description:
A. Name of the parts
SETTING BUTTON
FUNCTION BUTTON
CARRYING CASE
ALKALINE
BATTERY
UM-4 (AAA) 1.5V x 2
LCD DISPLAY
START/STOP
BUTTON
RECALL MEMORY
BUTTON
WRIST CUFF
* Figure No.3
B. Description of display symbols
MEASURING —
BLOOD PRESSURE
UNIT
BATTERY
WEAK DISPLAY |
ERROR SYMBOL —
MEMORY RECORD —
MONTH DATE HOUR MINUTE
ВВ
L — 1
r
Ss
=
5
3
3
=
e
Я |
m
=
=
o
=
88
|
|
18-38 (В
tm
E
|
FOOD
ZZ
EE
Oo
Е
=
PULSE SYMBOL
y
(an
— AFTERNOON TIME
— SYSTOLIC RATE
— DIASTOLIC RATE
J
т PULSE RATE
5. Changing batteries
Remove the battery cover at the lower side of the unit and insert
batteries into the battery compartment as shown, taking extreme
care that the polarities + and - are observed .
Important notice: Your might encounter difficulties to take the
batteries out. If so, use a hard and tiny object such as pen or
others for help.
* Figure No.4
6. Attaching pressure cuff
A. Wrap the pressure cuff around the wrist.
mln»
=
ND
a. the display of the unit should be placed
on the palm side of the wrist.
b. the wrist should be bare.
* Figure No.5
B. Fasten the pressure cuff snugly.
* Figure No.5-1
7. Correct measurement position
It is extremely important for the measured values,
that the cuff is at the same height of the heart.
Higher or deeper position will give deviations
from the true value.
Measurement while sitting down:
a. Place your elbow on a table or other object
(such as our carry case).
b. Use the armrest to position the arm so
that the pressure cuff is at the same
height as the heart.
c. Relax your hand with the palm facing up.
* Figure No.6
8. Description of display marks
Display mark
Condition/Cause
Corrective action
Mark appears in the
measurement condition
and flashes when pulse
is detected.
Measurements in
progress remain quiet.
Replace batteries
Appears when the battery
voltage is excessively low
or the positions of batteries
are incorrect.
Replace all two batteries
by new ones.
Insert the batteries at
correct positions beware
of the +/- directions.
Measuring error
ERROR
Appears when the accurate
blood pressure could not
be obtained accurately.
Press "start/stop" button
again and re-measure.
Or check cuff if wrapped
at the wrist or according
to instructions Check
palm if exerting effort.
Check if talking or moving
during measurement.
Check if posture is incorrect.
Measuring
blood pod
pressure &
symbol
Appears all the time till
the measurement being
completed.
9. How to measure
A. Inserting batteries in position:
a.
b.
Open battery cover.
Refer to the picture in positioning batteries. (Figure No.4)
c. All LCD segments appear on the display in 3 seconds.
d.
Display 1 month 1 date, 12 hour 0 minute.
B. Setting Date and Time:
a.
Press (MODE button ("month" starts flashing)
Press(_SET button to set the correct month (1,2,3,......12)
. Press (MODE)button again ("date" starts flashing)
Press button to set the correct date
. Press (MODE button again ("hour" starts flashing)
Press ( SET )button to set the correct hour in 12-hour format
. Press (MODE button again ("minute starts flashing)
Press(_SET button to set the correct minute (0,1,2,3.....59)
. Press (MODE button again to switch to normal time
(month, date, hour and minute appear on the display)
C. Steps to take blood pressure measurement:
a.
Wrap the cuff around the wrist (Refer to Wrapping of Wrist
cuff as (Figure No. 5)
b. Sit upright on the chair to have correct posture. (Refer to
Correct Posture in Taking Blood Pressure as (Figure No. 6)
c. Press START/STOP button. All elements display '888' in
3 seconds. Afterward, displays the update time. The
measuring blood pressure symbol will flash on the display
and then the air pressure will automatically pump up to
195 mmHg. If blood pressure tends to be on the high level,
the air pressure will automatically increase to the required
level for measurement. *Do not move or talk in the midst
of taking blood pressure measurement.
d. After the air pressure is increased, it will slowly decreased.
When the pulse rate is detected, HEART RATE symbol
will start flashing.
e. After taking blood pressure measurement, the Systolic
rate, Diastolic rate will be lasting flash on the display for
1 minute.
D. Storing, recalling and erasing measurement data:
a. Storing data:
After each blood pressure measurement, the Systolic rate,
diastolic rate, heart pulse rate and the time & date of specific
day will be automatically stored. The memory holds the
latest 99 measurement data. If more than 99 measurements,
the memory will automatically clear out the earliest data.
b. Recalling data:
(1) Pressing " RECALL " button at normal time, nothing will
appear on the display if there is on data in the memory.
If there is data in the memory, the latest recorded set of
measurement which are the Systolic rate, Diastolic rate,
heart pulse, including the recording time and date, will
appear and lasting on the display for 1 minute.
(60 sec)
(2) Press " RECALL " button to read the next line of stored
data.The data called up on the display is numbered
accordingly. After reading the recalled data as rotatory
99-set of the stored data, press " RECALL " to switch
to normal time.
(3) To discontinue in the midst of reading of the data, press
START/STOP button to power Off.
c. Erasing data:
(1). Take out the batteries and then refill 2 pcs batteries again.
(2). To discontinue if the data is erased. Press " RECALL"
button, no data should show up on the screen.
E. To change batteries:
When" [X12 " show up on the display, the battery is weak.
Change the batteries or it will not be possible to take blood
pressure measurement.
10. MAINTENANCE:
O Use a piece of cloth with water or mild cleansing agent to clean the
case and then use a piece of dry cloth to wipe it dry.
O Do not use gas or any strong cleansers in cleaning.
O When the unit is not to be used for a long time, remove the batteries.
(Leaking of battery liquid can cause trouble)
11. SAFE-KEEPING:
O Always keep the unit in the carrying case after its use.
© Do not put the item directly under the sunlight, in high
temperature, or humid and dusty places.
O Do not store in extremely low (less than - 20%C) or high
(more than 60°C) temperature.
12. TO PREVENT MALFUNCTION:
O Do not in any way twist the wrist cuff
O Do not start the air pressure when the wrist cuff is not wrapped
around the wrist.
© Do not attempt to disassemble or change any parts of the
monitor including wrist cuff.
O Do not drop the product or put it through strong impact.
14
13. WARNING:
O The device measures the blood pressure of adult only.
O The device is not supposed to be used if your wrist has any
wound or injury.
O In case the cuff is pumping up and non-stop, please open the
cuff at once.
14. SPECIFICATIONS:
Model No. : KH-8099
Method of Measurement : Oscillometric
Range of Measurement : Pressure 0~300mmHg, pulse
40~200 beats/minute
Accuracy Calibration : Pressure +/-3mmHg, Pulse +/-5%
Fuzzy Pressure : Automatic Re-inflation pump system
Inflation : Automatic inflation (Air Pump)
Deflation of Pressure : Automatic air release control valve
Exhaust : Automatic exhaust valve
Display : Liquid Crystal Digital Display
Unit Dimension : L70 x W72 x H29mm
Unit Weight : Approx. 140g including batteries
Sets of Memory : 99-set
Cuff Size : Wrist circumference approx.
135-195mm
Operating Temperature : +10°C to +40°C, 30~85% RH
Storage Temperature : -20°C to +50°C, 10-95%RH
Power Supply : 2x "AAA" (3.0V) ALKALINE
Battery Life : Approx. 250 times measurement
Accessories : Carrying case, instruction manual,
2 pcs "AAA" battery
These specification are subject to change without notice for
purpose of improvement.
16
Note:
Measurement accuracy results were obtained by studies conduct
at hospital in Taiwan.
The CE mark of the device corresponds to EC directive 93/42/EEC.
The blood pressure measuring device corresponds to European
regulations EN1060 part 1 and EN1060 part 3.
The device complies with the EMC requirements according
IEC 60601-1-2.
User group; the device is not suitable for invasive blood
pressure measuring in adults or children. It is suitable for
non-invasive blood pressure measuring for adults only.
CE 0197
17

advertisement

Key Features

  • Wrist blood pressure monitoring
  • Oscillometric method
  • Automatic inflation/deflation
  • Memory for 99 readings
  • Easy-to-use interface
  • Clear LCD display
  • Date & time setting
  • Battery powered

Related manuals

Frequently Answers and Questions

How do I set the date and time on the Kompernass Blood Pressure Monitor KH 8099?
Press the MODE button repeatedly to cycle through the month, date, hour, and minute settings. Use the SET button to adjust the desired values.
How many measurements can the device store?
The Kompernass Blood Pressure Monitor KH 8099 can store up to 99 measurements.
What does the ERROR symbol mean on the display?
The ERROR symbol indicates an inaccurate measurement. It could be due to incorrect cuff placement, movement during measurement, or other factors. Refer to the instructions for troubleshooting tips.

advertisement