Kompernass Blood Pressure Monitor KH 8099 User manual
Add to My manuals10 Pages
The Kompernass Blood Pressure Monitor KH 8099 is a compact and user-friendly device designed to accurately measure your systolic and diastolic blood pressure, as well as your pulse rate. With its oscillometric measurement method, this monitor provides reliable readings directly on its clear LCD display. The device features a memory function to store and recall up to 60 measurements, allowing you to conveniently track your blood pressure over time. Additionally, the monitor comes with a carrying case for easy storage and portability, making it ideal for home or travel use.
advertisement
▼
Scroll to page 2
of
10
Contents 01... Blood Pressure Monitor Intended Use 02....... 1. What is blood pressure ? 02....... 2. Why is it useful measure blood pressure at home ? rere A. WHO blood pressure classifications TT B. Variations in blood pressure 04....... 3. Important information before use of the unit 06....... 4. Device description errr A. Name of the parts panacaa es B. Description of display symbols 08....... 5. Changing Batteries 08....... 6. Attaching pressure cuff 09....... 7. Correct measurement position С ontent 8. Description of display marks. 9. How to measure. A. Inserting batteries in position. B. Setting date and time. D. Storing recalling and erasing measurement data. E. To change batteries. 14....... 10. Maintenance. 14....... 11. Safe-keeping. 14....... 1 2. To prevent malfunction. 15....... 13. Warning. 16....... 14. Specifications. 17....... Note C. Steps to take blood pressure measurement. Blood Pressure Monitor Intended Use: Measures human beings Systolic, Diastolic blood pressure and heart rate using the oscillometric method. All values can be read out in one LCD DISPLAY. Measurement position is on adult wrist only. Having one's blood pressure measured by a doctor in a hospital tends to stimulate nervousness in the person and may even create high blood pressure. Blood pressure in accordance with variety of conditions varies. So judgment is not possible on the basis of a single measurement. It is better to take measurement at home. Regular home monitoring will let you have a record of your measurements. This information may provide a better reference of what your blood pressure really is, and may help your doctor make important decisions about your diagnosis and treatment. If end-user has one of the diseases as heart troubles, Kidney trouble or diabetes or Frustration problem of Blood vessel, please consult a doctor before using the devices. 1. What is blood pressure ? Blood pressure is a measurement of the force of blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the cardiac cycle. The highest pressure in the cycle is called the systolic blood pressure, the lowest is the diastolic blood pressure. Both pressure readings, the systolic and the diastolic are necessary to enable a physician to evaluate the status of a patient's blood pressure. Many factors such as physical activity, anxiety or the time of day, can influence your blood pressure. Blood pressure is typically low in the morning and increases from the afternoon to the evening. It is lower in the summer and higher in the winter. 2. Why is it useful to measure blood pressure at home ? Having one's blood pressure measured by a doctor in a hospital or a clinic, and a group health checks, tend to stimulate nervousness in the subject and may even create high blood pressure. Also varies blood pressure in accordance with a variety of conditions and so judgment is not possible on the basis of a single measurement. The blood pressure measured first thing in the morning after getting up, before taking any food and with the subject still, is known as the fundamental blood pressure. In practice it is rather difficult to record the fundamental blood pressure, but to come 2 as near as possible to measuring the blood pressure in an environment that is close to this, is why it is useful to take the measurement at home. A. WHO blood pressure classifications Standards for assessment of high or low blood pressure without regard to age, have been established by the World Health Organization (WHO), as shown in the chart. 3 3 TI o HYPERTENSION © © HIGH NORMAL NORMAL 130 139 mmHg Systolic Blood Pressure Diastolic Blood Pressure Ol * Figure No.1 B. Variations in blood pressure Individual blood pressures vary greatly both on a daily and a seasonal basis. These variations are even more pronounced in hypertense patients. Normally the blood pressure rises while at work and is at its lowest during sleeping period. (hypertense: means a person who has high blood pressure symptom.) 160 The graph below illustrated | 1 © в the variations in blood po pressure over a whole day |; « with measurement taken 7 © every five minutes. a — 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 45 67 8 91011 Time * Figure No.2 The thick line represents sleep. The rise in blood pressure at 4 PM (Ain the graph) and 12 PM (B in the graph) correspond to an attack of pain. 3. Important information before use of the unit © © The device comply with EMC requirements according to IEC60601-1-2, Radio transmitting equipment, cellular phones etc. Shall not be used in the close proximity of the device since this could influence the performance of the device. Particular precaution must be considered during use of strong emission sources such as High Frequency surgical equipment and similar so that e.g. The HF-cables are not routed on or near the device. If in doubt, contact qualified technician or your local representative. Blood pressure measurements should be interpreted by a physician or trained health professional who is familiar with your medical history. By using the unit regularly and recording the results for your physician to interpret, you keep your physician informed of the continuing trends in your blood pressure. Wind the cuff snugly around your wrist and the cuff must be at the same level as your heart. Do not vibrate the unit during measurement, or the proper measurement will not be achieved. 4 © Perform measurement quietly in a relaxed position. O Do not wind the cuff over jacket or sweater sleeve, or measurement cannot be done. © Keep in mind, that blood pressure naturally varies from time to time through out the day and also is affected by lots of different factors such as smoking, alcohol consumption, medicamentation and physical activity. O People with a condition that causes circulatory problems (diabetes, kidney disease, arteriosclerosis or poor peripheral circulation) may get lower readings with this monitor that with a blood pressure monitor that is used on the upper arm. Please consult your physician to determine if your wrist blood pressure accurately reflects your actual blood pressure. O Blood pressure measurement determine with the unit are equivalent to those obtained by a trained observer using the cuff / stethoscope auscultation method. Within the limits prescribed by the American National Standard for Electronic or Automated Sphygmomanometers. 4. Device description: A. Name of the parts SETTING BUTTON FUNCTION BUTTON CARRYING CASE ALKALINE BATTERY UM-4 (AAA) 1.5V x 2 LCD DISPLAY START/STOP BUTTON RECALL MEMORY BUTTON WRIST CUFF * Figure No.3 B. Description of display symbols MEASURING — BLOOD PRESSURE UNIT BATTERY WEAK DISPLAY | ERROR SYMBOL — MEMORY RECORD — MONTH DATE HOUR MINUTE ВВ L — 1 r Ss = 5 3 3 = e Я | m = = o = 88 | | 18-38 (В tm E | FOOD ZZ EE Oo Е = PULSE SYMBOL y (an — AFTERNOON TIME — SYSTOLIC RATE — DIASTOLIC RATE J т PULSE RATE 5. Changing batteries Remove the battery cover at the lower side of the unit and insert batteries into the battery compartment as shown, taking extreme care that the polarities + and - are observed . Important notice: Your might encounter difficulties to take the batteries out. If so, use a hard and tiny object such as pen or others for help. * Figure No.4 6. Attaching pressure cuff A. Wrap the pressure cuff around the wrist. mln» = ND a. the display of the unit should be placed on the palm side of the wrist. b. the wrist should be bare. * Figure No.5 B. Fasten the pressure cuff snugly. * Figure No.5-1 7. Correct measurement position It is extremely important for the measured values, that the cuff is at the same height of the heart. Higher or deeper position will give deviations from the true value. Measurement while sitting down: a. Place your elbow on a table or other object (such as our carry case). b. Use the armrest to position the arm so that the pressure cuff is at the same height as the heart. c. Relax your hand with the palm facing up. * Figure No.6 8. Description of display marks Display mark Condition/Cause Corrective action Mark appears in the measurement condition and flashes when pulse is detected. Measurements in progress remain quiet. Replace batteries Appears when the battery voltage is excessively low or the positions of batteries are incorrect. Replace all two batteries by new ones. Insert the batteries at correct positions beware of the +/- directions. Measuring error ERROR Appears when the accurate blood pressure could not be obtained accurately. Press "start/stop" button again and re-measure. Or check cuff if wrapped at the wrist or according to instructions Check palm if exerting effort. Check if talking or moving during measurement. Check if posture is incorrect. Measuring blood pod pressure & symbol Appears all the time till the measurement being completed. 9. How to measure A. Inserting batteries in position: a. b. Open battery cover. Refer to the picture in positioning batteries. (Figure No.4) c. All LCD segments appear on the display in 3 seconds. d. Display 1 month 1 date, 12 hour 0 minute. B. Setting Date and Time: a. Press (MODE button ("month" starts flashing) Press(_SET button to set the correct month (1,2,3,......12) . Press (MODE)button again ("date" starts flashing) Press button to set the correct date . Press (MODE button again ("hour" starts flashing) Press ( SET )button to set the correct hour in 12-hour format . Press (MODE button again ("minute starts flashing) Press(_SET button to set the correct minute (0,1,2,3.....59) . Press (MODE button again to switch to normal time (month, date, hour and minute appear on the display) C. Steps to take blood pressure measurement: a. Wrap the cuff around the wrist (Refer to Wrapping of Wrist cuff as (Figure No. 5) b. Sit upright on the chair to have correct posture. (Refer to Correct Posture in Taking Blood Pressure as (Figure No. 6) c. Press START/STOP button. All elements display '888' in 3 seconds. Afterward, displays the update time. The measuring blood pressure symbol will flash on the display and then the air pressure will automatically pump up to 195 mmHg. If blood pressure tends to be on the high level, the air pressure will automatically increase to the required level for measurement. *Do not move or talk in the midst of taking blood pressure measurement. d. After the air pressure is increased, it will slowly decreased. When the pulse rate is detected, HEART RATE symbol will start flashing. e. After taking blood pressure measurement, the Systolic rate, Diastolic rate will be lasting flash on the display for 1 minute. D. Storing, recalling and erasing measurement data: a. Storing data: After each blood pressure measurement, the Systolic rate, diastolic rate, heart pulse rate and the time & date of specific day will be automatically stored. The memory holds the latest 99 measurement data. If more than 99 measurements, the memory will automatically clear out the earliest data. b. Recalling data: (1) Pressing " RECALL " button at normal time, nothing will appear on the display if there is on data in the memory. If there is data in the memory, the latest recorded set of measurement which are the Systolic rate, Diastolic rate, heart pulse, including the recording time and date, will appear and lasting on the display for 1 minute. (60 sec) (2) Press " RECALL " button to read the next line of stored data.The data called up on the display is numbered accordingly. After reading the recalled data as rotatory 99-set of the stored data, press " RECALL " to switch to normal time. (3) To discontinue in the midst of reading of the data, press START/STOP button to power Off. c. Erasing data: (1). Take out the batteries and then refill 2 pcs batteries again. (2). To discontinue if the data is erased. Press " RECALL" button, no data should show up on the screen. E. To change batteries: When" [X12 " show up on the display, the battery is weak. Change the batteries or it will not be possible to take blood pressure measurement. 10. MAINTENANCE: O Use a piece of cloth with water or mild cleansing agent to clean the case and then use a piece of dry cloth to wipe it dry. O Do not use gas or any strong cleansers in cleaning. O When the unit is not to be used for a long time, remove the batteries. (Leaking of battery liquid can cause trouble) 11. SAFE-KEEPING: O Always keep the unit in the carrying case after its use. © Do not put the item directly under the sunlight, in high temperature, or humid and dusty places. O Do not store in extremely low (less than - 20%C) or high (more than 60°C) temperature. 12. TO PREVENT MALFUNCTION: O Do not in any way twist the wrist cuff O Do not start the air pressure when the wrist cuff is not wrapped around the wrist. © Do not attempt to disassemble or change any parts of the monitor including wrist cuff. O Do not drop the product or put it through strong impact. 14 13. WARNING: O The device measures the blood pressure of adult only. O The device is not supposed to be used if your wrist has any wound or injury. O In case the cuff is pumping up and non-stop, please open the cuff at once. 14. SPECIFICATIONS: Model No. : KH-8099 Method of Measurement : Oscillometric Range of Measurement : Pressure 0~300mmHg, pulse 40~200 beats/minute Accuracy Calibration : Pressure +/-3mmHg, Pulse +/-5% Fuzzy Pressure : Automatic Re-inflation pump system Inflation : Automatic inflation (Air Pump) Deflation of Pressure : Automatic air release control valve Exhaust : Automatic exhaust valve Display : Liquid Crystal Digital Display Unit Dimension : L70 x W72 x H29mm Unit Weight : Approx. 140g including batteries Sets of Memory : 99-set Cuff Size : Wrist circumference approx. 135-195mm Operating Temperature : +10°C to +40°C, 30~85% RH Storage Temperature : -20°C to +50°C, 10-95%RH Power Supply : 2x "AAA" (3.0V) ALKALINE Battery Life : Approx. 250 times measurement Accessories : Carrying case, instruction manual, 2 pcs "AAA" battery These specification are subject to change without notice for purpose of improvement. 16 Note: Measurement accuracy results were obtained by studies conduct at hospital in Taiwan. The CE mark of the device corresponds to EC directive 93/42/EEC. The blood pressure measuring device corresponds to European regulations EN1060 part 1 and EN1060 part 3. The device complies with the EMC requirements according IEC 60601-1-2. User group; the device is not suitable for invasive blood pressure measuring in adults or children. It is suitable for non-invasive blood pressure measuring for adults only. CE 0197 17
advertisement
Key Features
- Wrist blood pressure monitoring
- Oscillometric method
- Automatic inflation/deflation
- Memory for 99 readings
- Easy-to-use interface
- Clear LCD display
- Date & time setting
- Battery powered
Related manuals
Frequently Answers and Questions
How do I set the date and time on the Kompernass Blood Pressure Monitor KH 8099?
Press the MODE button repeatedly to cycle through the month, date, hour, and minute settings. Use the SET button to adjust the desired values.
How many measurements can the device store?
The Kompernass Blood Pressure Monitor KH 8099 can store up to 99 measurements.
What does the ERROR symbol mean on the display?
The ERROR symbol indicates an inaccurate measurement. It could be due to incorrect cuff placement, movement during measurement, or other factors. Refer to the instructions for troubleshooting tips.
advertisement