광고
광고
Murphy Display and Diagnostic Module Shutdown (LED) Red Alarm (LED) Amber MDDM-00071B Revised 04-02 Catalog Section 78 (00-02-0429) MDDM Series ■ Specifically Designed For SAE J1939 Controller Scroll Up Description The Murphy Display and Diagnostic Module (MDDM) is the keystone in a line of components manufactured by FWMurphy as part of its J1939 MurphyLinkTM System. The J1939 MurphyLinkTM System has been developed to meet the needs for instrumentation and control on electronically controlled engines communicating using the SAE J1939 Controller Area Network (CAN). The MDDM is a powerful, easy to use multifunction tool that enables the operator to view many different engine parameters and engine service codes. The MDDM includes a two line by eight character backlit LCD display. The top line displays data labels, i.e. "EngHrs". The bottom line displays appropriate units information i.e "80 psi" for oil pressure. The UP and DOWN push buttons located on the front of the MDDM, are used for scrolling through the parameters and viewing the menu list. Two LEDs (amber and red) are used to annunciate active fault messages received by the MDDM. Other components in the system are microprocessor-based analog gauges for displaying critical engine data broadcast by the ECM: engine RPM, oil pressure, coolant temperature, system voltage, etc., a combination audible alarm and relay unit for warning and shutdown annunciation. Up to 32 components may be linked to the MDDM by an RS485 daisy chained twisted pair cable up to 1,000 meters from the Scroll Down Area Network (CAN) Equipment Applications ■ Displays Over 30 Standard SAE J1939 Parameters Broadcast by Major Engine and Transmission Manufacturers’ ECM’s ■ Displays Active Faults and ECM Stored Fault Codes For Diagnosing Equipment Malfunctions ■ Re-broadcasts Critical Data to MLink Analog Gages MDDM. The MDDM and all connected components can be powered by 12 or 24 volt systems, are back lit using LEDs, and are 100% environmentally sealed. Engine Parameters The following are some of the engine parameters displayed by the MDDM in English or Metric units (when applicable): Engine Hours Engine RPM ● System Voltage ● % Engine Load at the current RPM ● Coolant Temperature ● Oil Pressure ● Fuel Economy ● Throttle Position ● Manifold Air Temperature ● Current Fuel Consumption ● Active Service Codes ● Stored Service Codes from the engine ● Set the Units for display ● View Engine Configuration Parameters ● ● Applications The Murphy Display and Diagnostic Module is a low-cost solution for your instrumentation needs on stationary or mobile equipment applications. TM Specifications Bezel: Stainless Steel (Black Optional). Membrane Switch: Polyester. Case/Clamp: Nickel Plated Steel, Aluminum Killed, QQ-S-698. Maximum Panel Thickness: 0.30 inch. (8 mm). Mounting Hole: 2.062 inch (52 mm) in diameter. Dial: White on Black. Reversed Polarity: Withstands reversed battery terminal polarity indefinitely within operating temperatures. CAN BUS: SAE J1939 Compliant. Auxiliary Gage Communication: RS485. Operating Voltage: 8 VDC Minimum to 32 VDC Maximum. Operating Temperature: -4 to 158°F (-20 to 70°C). Storage Temperature: -40 to 185°F (-40 to 85°C). Shipping Weights (all models): 1 lb. (45 g.). Shipping Dimensions (all models): 5-1/2 x 5-1/2 x 5-1/2 in. (140 x 140 x 140 mm). Warranty A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm Dimensions IMPORTANT: The MDDM display is best viewed either straight on or at the 6 o’clock position. Panel 0.30 in. (8 mm) Alarm (LED) Amber maximum thickness Shutdown (LED) Red Mounting Clamp Ø2.03 in. (52 mm) MDDM Scroll Down Connector Option “D” AMP/DeutschTM Ø2.062 in. (52 mm) Dia. Connector Option “B” DeutschTM Wires Length 3 in. (76 mm) Connector Option “C” Metri-PackTM Wires Length 3 in. (76 mm) P/N: DT04-08PA 8-Way Connector 1.78 in. (45 mm) P/N: 12047931 8-Way Connector 1.88 in. (48 mm) MLA20-A-100-A = Oil Engine Pressure MLA20-B-250-A = Coolant Temperature MLA20-C-12-A = Voltmeter 12 VDC MLA20-C-24-A = Voltmeter 24 VDC MLA20-D-100-A = Percent Load @Current Speed MLA20-E-400-A = Gear Oil Pressure MLA20-F-250-A = Gear Oil Temperature MLA35-T-3000-A = Tachometer MLA35-S-85-A = Speedometer MLAA20 = Audible Alarm MLVC2412 = Regulator for 24 VDC systems MDDM 20 – B – B Connector B = DeutschTM (DT04-08PA) C = Metri-PackTM (12047931) D = AMP/DeutschTM (12047931) MURPHY DE MEXICO, S.A. DE C.V. Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384 +52 444 8206264 fax +52 444 8206336 Villahermosa Office +52 993 3162117 e-mail [email protected] www.murphymex.com.mx FRANK W. MURPHY, LTD. Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K. +44 1722 410055 fax +44 1722 410088 e-mail [email protected] www.fwmurphy.co.uk MURPHY SWITCH OF CALIFORNIA 41343 12th Street West Palmdale, California 93551-1442; USA +1 661 272 4700 fax +1 661 947 7570 e-mail [email protected] www.murphyswitch.com MACQUARRIE CORPORATION 1620 Hume Highway Campbellfield, Vic 3061; Australia +61 3 9358 5555 fax +61 3 9358 5558 e-mail [email protected] RE FW Murphy P.O. Box 470248 Tulsa, Oklahoma 74147 USA +1 918 317 4100 fax +1 918 317 4266 e-mail [email protected] www.fwmurphy.com Bezel Type Blank = A-20 Type A = A-20 Type Black B = SAE Type Low Profile CONTROL SYSTEMS & SERVICES DIVISION P.O. Box 1819; Rosenberg, Texas 77471; USA +1 281 633 4500 fax +1 281 633 4588 e-mail [email protected] P/N: DT04-3P 3-Way Connector 1.78 in. (45 mm) TM To order the MDDM use the model number designation diagram below. Size 20 = 2-1/16 in. (52 mm) Mounting hole. Wires Length 25 in. (635 mm) Accessories MurphyLink Analog Gages How to Order Model MDDM = Murphy Display and Diagnostic Module P/N: MTA-156 5-Way Connector 0.656 in. (17 mm) GI D Scroll Up Mounting Hole 2.13 in. (54 mm) E Mounting Clamp STER USA–ISO 9001:2000 FM 28221 UK–ISO 9001:2000 FM 29422 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. Printed in U.S.A. MDDM-00071B page 2 of 2 ">
/
다운로드
친절한 알림입니다. 여기에서 문서를 볼 수 있습니다. 그러나 가장 중요한 것은 AI가 이미 읽었다는 것입니다. 복잡한 내용을 간단하게 설명하고, 모든 언어로 질문에 답변하고, 가장 길거나 복잡한 문서도 빠르게 탐색할 수 있도록 도와줍니다.
광고