- Industrial & lab equipment
- Electrical equipment & supplies
- Power conditioning
- Electrical relays
- Panasonic
- Switch LD Relays (ALD)
- User manual
advertisement
▼
Scroll to page 2
of
3
![Panasonic Switch LD Relays (ALD) User manual | Manualzz Panasonic Switch LD Relays (ALD) User manual | Manualzz](http://s3.manualzz.com/store/data/051398049_1-86ff102314c6f29feb7e3eac11fecc47-360x466.png)
LD (ALD) VDE 1 FORM A SLIM POWER RELAY 20.3 .799 LD RELAYS (ALD) FEATURES 7.0 .276 15.0 .591 mm inch RoHS Directive compatibility information http://www.nais-e.com/ 4. High shock resistance The relay withstands a functional shock resistance of 300m/s2 [approx. 30 G more] 5. High insulation resistance • Creepage distance and clearances between contact and coil: Min. 6 mm .236 inch (In compliance with IEC65) • Surge withstand voltage between contact and coil: 10,000 V or more. 6. UL/CSA, VDE, TÜV approved. 1. Slim type: Width 7 mm .276 inch. 20.3(L)×7.0(W)×15.0(H) mm .799(L)×.276(W)×.591(H) inch 2. Perfect for small load switching of home appliances 105 switching operations possible with a 3A 250V AC resistive load. 3. Low operating power Compact size, nominal operating power as low as 200mW. SPECIFICATIONS Contact Characteristics Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material 1 Form A Max. 100 mΩ Max. switching power Max. switching voltage Max. switching current Min. switching capacity#1 Mechanical (at 180 cpm) Expected life 3A 125V AC, Electrical (min.operations) (at 20 cpm) 3A 30V DC (at rated load) 3A 250V AC Between open contacts Between contact and coil Initial surge voltage between contact and coil*3 Operate time*4 (at nominal voltage) Release time (with diode)*4 (at nominal voltage) 3 A 277 V AC, 3 A 30V DC 831 V A (AC), 90W (DC) 277 V AC, 30 V DC 3A 100 mA, 5 V DC 5×106 105 Coil 200 mW Remarks Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Unit weight * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as “Initial breakdown voltage” section. *2 Detection current: 10mA *3 Wave is standard shock voltage of ±1.2×50ms according to JEC-212-1981 *4 Excluding contact bounce time. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs *6 Half-wave pulse of sine wave: 6 ms *7 Detection time: 10 µs *8 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT • Air conditioner • Refrigerator • Hot water units • Microwave ovens • Fan heaters Min. 10,000 V Max. 10ms (at 20°C 68°F) Max. 10ms (at 20°C 68°F) Humidity 5 to 85% R.H. Functional*7 Vibration resistance 4,000 Vrms for 1 min. Ambient temp. Functional*5 Destructive*6 #1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. TYPICAL APPLICATIONS 750 Vrms for 1 min. Max. 45°C with nominal coil voltage and at 3 A contact carrying current (resistance method) Min. 300 m/s2{approx. 30 G} Min. 1,000 m/s2{approx. 100 G} 10 to 55Hz at double amplitude of 1.5mm 10 to 55Hz at double amplitude of 1.5mm –40°C to +70°C –40°F to +158°F Temperature rise (at 70°C 158°F) 2×105 Shock resistance Nominal operating power 20 cpm (at rated load) Min. 1,000 MΩ (at 500 V DC) Initial*2 breakdown voltage AgSnO2 type Nominal switching capacity Rating (resistive load) Max. operating speed Initial insulation resistance*1 Destructive Approx. 4 g .14 oz ORDERING INFORMATION Ex. A LD 1 12 W Product name Contact arrangement Coil voltage (V DC) Packing style LD 1: 1 Form A 4H: 4.5, 09: 9 , 24: 24 12: 12 05: 5, 18: 18 06: 6, Nil: Tube packing W: Carton packing UL/CSA, TÜV, VDE approved type is standard. Note: Tube packing: Tube: 50pcs, Case: 1,000pcs Carton packing: Carton: 100pcs, Case: 500pcs All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. LD (ALD) TYPES AND COIL DATA (at 20°C 68°F) Part No. Nominal voltage, V DC Pick-up voltage, V DC (max.) (Initial) Drop-out voltage, V DC (min.) (Initial) Coil resistance, Ω (±10%) ALD14H ALD105 ALD106 ALD109 ALD112 ALD118 ALD124 4.5 5 6 9 12 18 24 3.38 3.75 4.5 6.75 9 13.5 18 0.22 0.25 0.3 0.45 0.6 0.9 1.2 101 125 180 405 720 1,620 2,880 Nominal operating current, mA (±10%) 44.6 40.0 33.3 22.2 16.7 11.1 8.3 Nominal operating power, mW 200 200 200 200 200 200 200 Maximum allowable voltage, V DC (at 20°C 68°F) 5.85 6.5 7.8 11.7 15.6 23.4 31.2 DIMENSIONS mm inch PC board pattern (Bottom view) Max. 7.2 .284 Max. 20.5 .807 (1.05) (.041) Max. 15.3 .602 3.4 0.4 .134 .016 0.4 dia 016 dia 1.05 .041 0.2 .008 11.5 .453 11.5 .453 7.0 .276 (1.15) (.045) 4-1.1 dia 4-.043 dia 4.7 .185 Tolerance: ±0.1 ±.004 0.2 .008 0.8 .031 4.7 .185 7.0 .276 Schematic (Bottom view) 1.15 .045 COM Dimension: General tolerance Max. 1mm .039 inch: ±0.1 ±.004 1 to 3mm .039 to .118 inch: ±0.2 ±.008 Min. 3mm .118 inch: ±0.3 ±.012 NO COIL REFERENCE DATA 1. Max. switching power 2. Life curve 3. Coil temperature rise Sample: ALD112, 6 pcs. Point measured: inside the coil Contact current: 0 A, 3 A 100 70 50 60 0A 3A AC resistive load DC resistive load 1.0 125V AC resistive load 30 10 0.5 0.4 Temperature rise, °C 2.0 Life, ×104 Contact current, A 3.0 0.3 20°C 50 40 70°C 30 20 0.2 10 0 20 30 50 100 0 200 300 1 2 0 3 0 100 Contact current, A Contact voltage, V 125 150 Coil applied voltage, %V 4-(2). Release time (without diode) 4-(3). Release time (with diode) Sample: ALD112, 6 pcs. Sample: ALD112, 6 pcs. Sample: ALD112, 6 pcs. 10 10 8 8 8 6 4 Release time, ms 10 Release time, ms Operate time, ms 4-(1). Operate time 6 4 Max. 6 4 Min. Max. Min. 2 2 2 Max. Min. 0 80 100 120 140 Coil applied voltage, %V 0 80 100 120 140 0 Coil applied voltage, %V All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. 80 100 120 140 Coil applied voltage, %V 175 LD (ALD) 250V AC 12V DC 60Hz G NO Change of contact resistance 100 100 90 90 Contact resistance, mΩ Sample: ALD112, 6 pcs. Operating speed: 20 cpm Ambient temperature: room temperature circuit: Change of pick-up and drop-out voltage Ratio against the rated voltage, %V 5-(1). Electrical life test (3 A 250 V AC, resistive load) 80 70 Pick-up voltage Max. 60 Min. 50 40 30 Drop-out voltage Max. Min. 20 0 70 60 50 40 30 20 Max. Min. 10 10 COM 80 0 10 0 No. of operations, ×104 30V DC G 12V DC NO COM Change of contact resistance 100 100 90 90 80 Pick-up voltage 70 Max. 60 Min. 50 40 Drop-out voltage 30 Contact resistance, mΩ Sample: ALD112, 6 pcs. Operating speed: 20 cpm Ambient temperature: room temperature circuit: Change of pick-up and drop-out voltage Ratio against the rated voltage, %V 5-(2). Electrical life test (3 A 30 V DC, resistive load) Max. Min. 20 80 70 60 50 40 30 Max. 20 Min. 10 10 0 10 0 No. of operations, ×104 0 10 No. of operations, 20 ×104 For Cautions for Use, see Relay Technical Information . All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. 0 0 10 No. of operations, ×104 20
advertisement