advertisement
▼
Scroll to page 2
of 45
ITALIANO ESPAÑOL FRANÇAIS DEUTSCH ΕΛΛΗΝΙΚΆ AIR CONDITIONER ENGLISH РУССКИЙ ЯЗЫК УКРАÏНСЬКА ҚАЗАҚ ТІЛІ БЕЛАРУСКАЯ МОВА O‘ZBEK TILI OWNER’S MANUAL ČEŠTINA CEILING CASSETTE, CEILING CONCEALED DUCT Original instruction POLSKI www.lg.com Copyright © 2016 - 2019 LG Electronics Inc. All Rights Reserved. LIMBA ROMÂNĂ [Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands [Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA MFL67870330 Rev.01_030519 NEDERLANDS Please read this manual carefully before operating your set and retain it for future reference. 2 TIPS FOR SAVING ENERGY ENGLISH TIPS FOR SAVING ENERGY Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below: • Do not cool excessively indoors. This may be harmful for your health and may consume more electricity. • Block sunlight with blinds or curtains while you are operating the air conditioner. • Keep doors or windows closed tightly while you are operating the air conditioner. • Adjust the direction of the air flow vertically or horizontally to circulate indoor air. • Speed up the fan to cool or warm indoor air quickly, in a short period of time. • Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner is used for many hours. • Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions. For your records Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here: Model number : Serial number : You can find them on a label on the side of each unit. Dealer’s name : Date of purchase : IMPORTANT SAFETY INSTRUCTIONS 3 The following symbols are displayed on indoor and outdoor units. Read the precautions in this manual carefully before operating the unit. This appliance is filled with flammable refrigerant (R32) This symbol indicates that the Operation Manual should be read carefully. This symbol indicates that a service personnel should be handling this equipment with reference to the Installation Manual. READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE. Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product ! WARNING It can result in serious injury or death when the directions are ignored ! CAUTION It can result in minor injury or product damage when the directions are ignored. This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons. ! WARNING • Always ground the product. There is a risk of electric shock. • Do not use a defective or underrated circuit breaker. Use the correctly rated breaker and fuse. There is risk of fire or electric shock. • Do not use a multi consent. Always use this appliance on a dedicated cicuit and breaker. Otherwise it can cause electric shock or fire. • For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. Do not disassemble or repair the product by yourself. There is risk of fire or electric shock. • Always ground the product as per the wiring diagram. Do not connect the ground wire to gas or water pipes lightening rod or telephone ground wire. There is risk of fire or electric shock. • Install the panel and the cover of control box securely. There is risk of fire or electric shock due to dust, water etc. ENGLISH IMPORTANT SAFETY INSTRUCTIONS 4 IMPORTANT SAFETY INSTRUCTIONS ENGLISH • Use the correctly rated breaker or fuse. There is risk of fire or electric shock. • Do not modify or extend the power cable. If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced. There is risk of fire or electric shock. • For installation, removal or reinstall, always contact the dealer or an Authorized Service Center. There is risk of fire, electric shock, explosion, or injury. • Do not install the product on a defective installation stand. Be sure that the installation area does not deteriorate with age. It may cause product to fall. • Never install the outdoor unit on a moving base or a place from where it can fall down. The falling outdoor unit can cause damage or injury or even death of a person. • When the product is soaked (flooded or submerged) in water, contact an Authorized Service Center for repair before using it again. There is risk of fire or eletric shock. • Be sure to check the refrigerant to the used. Please read the label on the product. Incorrect refrigerant used can prevent the normal operation of the unit. • Don't use a power cord, a plug or a loose socket which is damaged. Otherwise it may cause a fire or electrical shock. • Do not touch, operate, or repair the product with wet hands. Hold the plug by hand when taking out. There is risk of electric shock or fire. • Do not place a heater or other heating appliances near the power cable. There is risk of fire and electric shock. • Do not allow water to run into electric parts. Install the unit away from water sources. There is risk of fire, failure of the product, or electric shock. • Do not store or use or even allow flammable gas or combustibles near the product. There is risk of fire. • Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals. Improper or IMPORTANT SAFETY INSTRUCTIONS 5 ENGLISH loose connections can cause heat generation or fire. • Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after installation or svc and then tear away and thraw away the plastic packaging bags. Children may play with them and cause injury. • Make sure to check that the power cable plug is not dirty, loose or broken and then only insert the plug completely. Dirty, loose or broken power plug can cause electric shock or fire. • In outdoor unit the step-up capacitor supplies high voltage electricity to the electrical components. Be sure to discharge the capacitor completely before conducting the repair work. An charged capacitor can cause electrical shock. • When installing the unit, use the installation kit provided with the product. Otherwise the unit may fall and cause severe injury. • Be sure to use only those parts which are listed in the svc parts list. Never attempt to modify the equipment. The use of inappropriate parts can cause an electrical shock, excessive heat generation or fire. • Do not use the product in a tightly closed space for a long time. Perform ventilation regularly. Oxygen deficiency could occur and hence harm your health. • Do not open the front grille of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.) There is risk of physical injury, electric shock, or product failure. • If strange sounds, smell or smoke comes from product. Immediately turn the breaker off or disconnect the power supply cable. There is risk of electric shock or fire. • Ventilate the product room from time to time when operating it together with a stove, or heating element etc. Oxygen deficiency can occur and hence harm your health. • Turn the main power off and unplug the unit when cleaning or repairing the product. There is risk of electric shock. • When the product is not to be used for a long time, disconnect the power supply plug or turn off the breaker. There is risk of product damage or failure, or unintended operation. • Take care to ensure that nobody especially kids could step on 6 IMPORTANT SAFETY INSTRUCTIONS ENGLISH or fall onto the outdoor unit. This could result in personal injury and product damage. • Take care to ensure that power cable could not be pulled out or damaged during operation. There is risk of fire or electric shock. • Do not place ANYTHING on the power cable. There is risk of fire or electric shock. • Do not plug or unplug the power supply plug to turn the unit ON/OFF. There is risk of fire or electric shock. • When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on. Do not use the telephone or turn switches on or off. There is risk of explosion or fire. • Do not turn on the breaker or power under condition that front panel, cabinet, top cover, control box cover are removed or opened. Otherwise, it may cause fire, electric shock, explosion or death. • Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge. Do not compress air or Oxygen and Do not use Flammable gases. Otherwise, it may cause fire or explosion. There is the risk of death, injury, fire or explosion. • The appliance shall be stored in a room without continuously operating ignition sources (for example : open flames, an operating gas appliance or an operating electric heater.) • Keep any required ventilation openings clear of obstruction. • The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation. (for R32) • Ducts connected to an appliance shall not contain an ignition source. (for R32) ! CAUTION • Two or more people must lift and transport the product. Avoid personal injury. • Do not install the product where it will be exposed to sea wind (salt spray) directly. It may cause corrosion on the product. IMPORTANT SAFETY INSTRUCTIONS 7 ENGLISH • Install the drain hose to ensure that the condensed water is drained away properly. A bad connection may cause water leakage. • Keep level even when installing the product. To avoid vibration or noise. • Do not install the product where the noise or hot air from the outdoor unit could damage or disturb the neighborhoods. It may cause a problem for your neighbors and hence dispute. • Always check for gas (refrigerant) leakage after installation or repair of product. Low refrigerant levels may cause failure of product. • Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system. There is risk of damage or loss of property. • Do not block the inlet or outlet of air flow. It may cause product failure. • Use a soft cloth to clean. Do not use harsh detergents, solvents or splashing water etc. There is risk of fire, electric shock, or damage to the plastic parts of the product. • Do not touch the metal parts of the product when removing the air filter. There is risk of personal injury. • Do not step on or put anyting on the product. (outdoor units) There is risk of personal injury and failure of product. • Always insert the filter securely after cleaning. Clean the filter every two weeks or more often if necessary. A dirty filter reduces the efficiency. • Do not insert hands or other objects through the air inlet or outlet while the product is operating. There are sharp and moving parts that could cause personal injury. • Be cautious when unpacking and installing the product. Sharp edges could cause injury. • If the refrigerant gas leaks during the repair, do not touch the leakaing refrigerant gas. The refrigernat gas can cause frostbite (cold burn) • Do not tilt the unit when removing or uninstalling it. The condensed water inside can spill. 8 IMPORTANT SAFETY INSTRUCTIONS ENGLISH • Do not mix air or gas other than the specified refrigerant used in the system. If air enters the refrigerant system, an excessively high pressure results, causing equipment damage or injury. • If the refrigerant gas leaks during the installation, ventilate the area immediately. Otherwise it can be harmfull for your health. • Dismantling the unit, treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards. • Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries. There is risk of fire or product failure. • Do not recharge or disassemble the batteries. Do not dispose off batteries in a fire. They may burn or explode. • If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked. The chemicals in batteries could cause burns or other health hazards. • If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked. The chemicals in batteries could cause burns or other health hazard. • Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. Moisture may condense and wet or damage furniture. • Do not expose your skin or kids or plants to the cool or hot air draft. This could harm to your health. • Do not drink the water drained from the product. It is not sanitary and could cause serious health issues. • Use a firm stool or ladder when cleaning, maintaining or repairing the product at an height. Be careful and avoid personal injury. • The air conditioner is not intended for use by young children or invalids without supervision. • Young children should be supervised to ensure that they do not play with the air conditioner. IMPORTANT SAFETY INSTRUCTIONS 9 ENGLISH • The appliance shall be stored so as to prevent mechanical damage from occurring. • Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification. (for R32) • Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants. (for R32) • Wear adequate personal protection equipment (PPE) when installing, maintaining or servicing the product. • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. • If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer of its service agent. • The appliance shall be installed in accordance with national wiring regulations. 10 TABLE OF CONTENTS ENGLISH TABLE OF CONTENTS 2 TIPS FOR SAVING ENERGY 3 IMPORTANT SAFETY INSTRUCTIONS 12 BEFORE USE 12 12 12 12 12 12 About the system Preparing for operation Usage Cleaning and maintenance Service Disposal 13 PRODUCT INTRODUCTION 13 13 14 14 15 16 Name and function of parts (CEILING CASSETTE) Name and function of parts (CEILING CONCEALED DUCT) Model designation Operation Indicator Lamp Wired Remote Controller Wireless Remote Controller (Accessory) 17 OPERATING INSTRUCTIONS 17 18 18 19 19 20 21 22 23 24 25 25 26 27 28 29 30 Standard Operation - Standard Cooling Standard Operation - Power Cooling Standard Operation - Heating Mode Standard Operation - Dehumidification Mode Auto Changeover Mode Standard Operation - Fan Mode Standard Operation - Auto Operation Mode Standard Operation - Airflow Setting Standard Operation - Temperature Setting/Room Temperature Check Sub Function - Plasma Purification(Accessory) Sub Function - Comfort Cooling Function Setting - Child Lock Function Setting - Change Temp Function Setting - Elevation Grill(Accessory) Function Setting - Filter Sign Clear Function Setting - Vane Angle Control Function Setting - Changing Current Time TABLE OF CONTENTS Programming - Simple Reservation Programming - Weekly Reservation Programming - Sleep Reservation Programming - ON Reservation Programming - OFF Reservation Programming - Holiday Reservation 41 MAINTENANCE AND SERVICE 41 42 43 43 44 44 Indoor Unit Purifying filter(Optional) Operation Tips! When the air conditioner is not going.... Troubleshooting Tips! Save time and money! Call the service immediately in the following situations ENGLISH 32 33 35 36 38 40 11 12 BEFORE USE ENGLISH BEFORE USE About the system This system of air conditioner can be used for heating/cooling applications. Preparing for operation • Contact an installation specialist for installation. • Use a dedicated circuit. Usage • Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time. • Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or other heating devices. • Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Such usage could damage the items. Cleaning and maintenance • Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges. • Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock. • When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit’s power is accidentally triggered on while cleaning inner parts of the unit. Service For repair and maintenance, contact your authorized service dealer. Disposal The unit uses hydrofluorocarbon. Contact your dealer when discarding this unit. It is required by law to collect, transport and discard the refrigerant in accordance with the “hydrofluorocarbon collection and destruction” regulations. PRODUCT INTRODUCTION 13 Name and function of parts (CEILING CASSETTE) 67 2 1 5 4 3 4 1: Indoor unit 2: Outdoor unit 3: Remote controller 4: Inlet air 5: Discharge air 6: Refrigerant piping, connection electric wire 7: Drain pipe 8: Ground wire Wire to ground outdoor unit to prevent electrical 8 shocks. Name and function of parts (CEILING CONCEALED DUCT) 1 4 67 2 5 3 8 1: Indoor unit 2: Outdoor unit 3: Remote controller 4: Inlet air 5: Discharge air 6: Refrigerant piping, connection electric wire 7: Drain pipe 8: Ground wire wire to ground outdoor unit to prevent electrical shocks. ENGLISH PRODUCT INTRODUCTION 14 PRODUCT INTRODUCTION ENGLISH Model designation - Product Name : Air conditioner - Model Name : C S 15 SQ N B 0 Serial number Chassis name Indoor Unit / Outdoor Units N : Indoor Unit U : Outdoor Unit Detailed product type for U- / C- series models L : Low Static H : High COP E : Econo R : Refrigerant R32 Nominal Capacity Ex) 7 000 Btu/h Class → '07', 18 000 Btu/h Class → '18' Product type T : Ceiling Cassette B, M : Ceiling Concealed Duct L : Ceiling Concealed Duct (Low Static) V : Ceiling Suspended & floor Connectable Outdoor unit type M : Indoor units only for Multi systems U : Indoor units only for Single A systems C : Common Indoor Unit for Multi and Single CAC Operation Indicator Lamp Lamp Forced operation Button Description Lamp Color Cooling mode Green Heating mode Green Time to clean filter in cooling/heating Mode Yellowish Green Time to clean filter when product is not operating Orange Hot start or defrost mode before starting heating mode Green When reservation set on Yellowish Green PRODUCT INTRODUCTION 15 ENGLISH Wired Remote Controller 1 8 7 9 14 2 10 11 12 4 5 13 6 15 3 1 2 3 4 5 6 OPERATION INDICATION SCREEN SET TEMPERATURE Button FAN SPEED Button ON/OFF Button OPRATION MODE SELECTION Button WIRELESS REMOTE CONTROLLER RECEIVER • Some products don't receive the wireless signals. 7 AIR FLOW Button 8 SUBFUNCTION Button 9 FUNCTION SETTING Button 10 VENTILATION Button 11 RESERVATION 12 UP,DOWN,LEFT,RIGHT Button • To check the indoor temperature, press button. Please attach the inform label inside of the door. Please choose proper language depend on your country. 13 ROOM TEMPERATURE Button 14 SETTING/CANCEL Button 15 ESC Button * Some functions may not be operated and displayed depending on the product type. ! NOTE • Display temperature can be different from actual room temperature if the remote controller is installed at the place where sun-rays are falling directly or the place nearby heat source. • The actual product can be different from above contents depending upon model type. • When using simultaneous operation system, whenever press remote controller button, system will approximately operate after 1~2 minutes. 16 PRODUCT INTRODUCTION ENGLISH Wireless Remote Controller (Accessory) This air-conditioner is equipped with wired remote controller basically. But if you want to be available with wireless remote controller, you pay for it. ! NOTE • The wireless remote controller do not operate the vane angle control.(4Way Type) • For more details refer to the Wireless Remote Control Accessory manual. • The actual product can be different from above contents depending upon model type. • The wireless remote controller does not operate When using simultaneous operation system. JET MODE * Some functions may not be operated and displayed depending on the product type. °C/°F (5 s) TIME (3 s) ! CAUTION CAUTION of handling the Remote Controller • Aim at the signal receiver on the wired remote controller so as to operate. • The remote control signal can be received at a distance of up to about 7m. • Be sure that there are no obstructions between the remote controller and the signal receptor. • Do not drop or throw the remote controller. • Do not place the remote controller in a location exposed to direct sunlight, or near the heating unit, or any other heat source. • Block a strong light over the signal receptor with a curtain or etc. so as to prevent the abnormal operation. (ex:electronic quick start, ELBA, inverter type fluorescent lamp) OPERATING INSTRUCTIONS 17 ENGLISH OPERATING INSTRUCTIONS Standard Operation - Standard Cooling It cools the room by comfortable and clean wind. 1 Press indoor. button to turn on the button to select 2 Press Cooling operation mode. the desired temperature 3 Adjust by pressing buttons. Press button to check the Room temperature. When setting the desired temperature higher than room temperature, only ventilation wind is blow out instead of cooling wind. 18 OPERATING INSTRUCTIONS ENGLISH Standard Operation - Power Cooling It makes the room cool using pleasant and fresh air quickly. 1 Press indoor. button to trun on the button to select 2 Press cooling operation mode. button continuously 3 Press until 'Po' displayed. What is Power Cooling? • Desired temperature: Po (actually 18 °C) It make room temperature • Wind flow: power wind drop fast by running • Wind direction: fix to air-cooling position h Partial product has no power air-cooling function. } Standard Operation - Heating Mode It supplies warm wind to the indoor. 1 Press indoor. button to turn on the button to select 2 Press Heating mode. (To check the indoor temperature, press the room temperature button.) the desired temperature 3 Adjust by pressing buttons. When setting the desired temperature lower than room temperature, there is only ventilation wind. • Heating drive only operates at the cooling and heating model. • Heating doesn't operate at cooling exclusive model. OPERATING INSTRUCTIONS 19 It removes humidity while air-cooling weakly. 1 Press indoor. button to turn on the button to select 2 Press Dehumidification mode. The temperature setting can not be adjusted during operation this mode. the button to select 3 Press airflow rate feeble → weak → medium → strong → automatic. (The initial wind powerfulness of humidity removal drive is 'weak'.) • In rainy season or high humidity climate, it is possible to operate simultaneously dehumidifier and cooling mode to remove humidity effectively. • The menu item of wind powerfulness might not be partially selected according to the product. Auto Changeover Mode 1 Press indoor. 2 Press button to turn on the button to select Auto Changeover Mode. setting temperature as the right side picture can be set in both 3 The cooling/ heating model. ENGLISH Standard Operation - Dehumidification Mode 20 OPERATING INSTRUCTIONS ENGLISH Standard Operation - Fan Mode It blows the air as it is in the indoor, not the cold wind. 1 Press indoor. button to turn on the 2 Press Mode. button to select Fan time pressing button, you 3 Every can select wind flow in order of feeble → weak → medium → strong → automatic. When running ventilation, compressor of AHU doesn't work. • Ventilation drive does not release cool wind but general fan • Because it releases the wind that has no temperature difference from the room, it functions to circulate the inside air. • The menu item of wind powerfulness might not be partially selected according to the product. OPERATING INSTRUCTIONS 21 ENGLISH Standard Operation - Auto Operation Mode 1 Press indoor. button to turn on the button to select 2 Press Artificial intelligence Mode. can adjust 3 You the temperature as the picture on the right for cooling and heating model. the case of 4 For cooling exclusive, as the picture on the right, you can adjust the temperature from hot to cold, from "-2" to "2" based on "00". During operating Auto Operation mode: • We can use the FAN SPEED button • We can change manually to other operation mode. When cold When cool When appropriate When warm When hot 22 OPERATING INSTRUCTIONS ENGLISH Standard Operation - Airflow Setting Wind powerfulness : You can simply adjust desired wind powerfulness. setup desired wind 1 Please powerfulness by wind powerfulness button. • Every time you press wind powerfulness, you can select the wind flow in order of ‘feeble → weak → weak medium → medium → medium strong → strong → power → automatic’. • The menu item might not be partially selected according to product function. Wind direction : You can simply adjust desired wind direction. 1 Please set desired wind direction by pressing button. You can select wind direction of (comfortable wind → Up/Down and Right/Left → Right/Left → Up/Down) by pressing button. Partial item of wind directions might not be selected according to product function. * Some functions may not be operated and displayed depending on the product type. OPERATING INSTRUCTIONS 23 Temperature Setting can simply adjust the desired 1 We temperature. • Press the buttons to adjust the desired temperature. : Increase 1 ˚C or 2 ˚F per one time pressing : Decrease 1 ˚C or 2 ˚F per one time pressing • Room temp: Indicate the current room temperature. • Set temp: Indicate the temperature that user want to set. * Depend on what kind of controller, the desired temperature can be adjusted at 0.5 ˚C or 1 ˚F. Cooling operation: - The cooling mode doesn't work if desired temperature is higher than room temperature Please lower the desired temperature. Heating operation: - The heating mode doesn't work if desired temperature is lower than room temperature Please increase the desired temperature. Room Temperature Check press button, the room 1 Whenever temperature will be displayed within 5 seconds. After 5 seconds, it turns to display the desired temperature. Because of location of remote controller, the real room temperature and the this displayed value can be different • 5 °C is proper for the difference between room and outside temperature. ENGLISH Standard Operation - Temperature Setting/Room Temperature Check 24 OPERATING INSTRUCTIONS ENGLISH Sub Function - Plasma Purification(Accessory) Only products with humidifying function can use this. The method to setup cleaning air pressing 1 Repeat until icon flash. button or cancel Plasma 2 Operate Purification function by pressing ( button. icon appears/disappears on display part up to selection ) setting, press 3 After to exit. button ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. • Cleaning air function is additional function and it might not be indicated or operated at the partial product. • Cleaning air function is possible only when product is running. • If you want independent cleaning air drive, please setup cleaning air by pressing additional drive button at ventilation drive. * Some functions may not be operated and displayed depending on the product type. OPERATING INSTRUCTIONS 25 The comfort cooling is the function to automatically control the cooling strength to maintain the pleasant feeling without turning off the product after the indoor temperature reached the desired temperature. button repeatedly until 1 Press Comfort cooling icon displayed. on/off Comfort cooling 2 Turn function by pressing button. ❈ The icon will be displayed in case of setting option and disappear in reverse case. button after setup. 3 Press ❈ If no button is selected for about 25 seconds after setup, it exits the setup mode button is not selected before ❈ If the you exit, the changes will not apply. * Some products may not include Comfort cooling function. Function Setting - Child Lock It is the function to use preventing children or others from careless using. button repeatedly until 1 Press the is flashing. moving to 'setup' icon area by 2 Ifusing button, 'setup' icon blinks, and child lock function is setup if pressing button at that time. cancelling lock function, if moving 3 When to 'cancel' icon by pressing button and then, pressing button, child lock function is cancelled. button to exit. 4 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. ENGLISH Sub Function - Comfort Cooling 26 OPERATING INSTRUCTIONS ENGLISH Function Setting - Change Temp Change temperature is the function to setup air-cooling and heating drive automatically changeable according to the temperature at artificial intelligence drive mode. 1 Repeaticonpressing flash. button until button to change. 2 Press ❈ Converting temp value : 1~7 button to complete 3 Press and active the setting process. button to exit or 4 Press system will automatically release without any input after 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. OPERATING INSTRUCTIONS 27 ENGLISH Function Setting - Elevation Grill(Accessory) This function is to move the indoor filter up/down for cleaning filter. button 1 Press Repeat pressing button until icon flash. to descent using button 2 Move and press button will display descent icon and the up/down grill will descent. up/down grill descents to the 3 When desired position, move to stop icon suing button and press to stop up/down grill. button filter cleaning is finished, fix the 4 When filter to the up/down grill, move to ascent icon using button, and press button to ascent up/down grill. button to exit. 5 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 60 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. • Elevation grill function only operates in the indoor unit with the elevation grill. * Some functions may not be operated and displayed depending on the product type. 28 OPERATING INSTRUCTIONS ENGLISH Function Setting - Filter Sign Clear This function is to clear the indicator of indoor filter cleaning. 1 Press until the button repeatedly is flashing. the is flashing, press 2 When the to clear this display • When filter is covered by dust, it will reduce cooling/heating efficiency and accumulate more electric power. Therefore. do clean the filter whenever cleaning time is expired. * Filter cleaning indication is automatically cancelled without the separate cancellation after certain period of time. OPERATING INSTRUCTIONS 29 ENGLISH Function Setting - Vane Angle Control This function is to adjust angle at which airflow is blow out. * Some functions may not be operated and displayed depending on the product type. pressing 1 Repeat icon flash. button until button to select active vane : 2 Press 1 / 2 / 3 / 4 / All / Standard Select Vane number using buttons. ❈ Vane number : No. 1, 2., 3, 4, all, or standard - Selected vane is in operation. - Please verify the operating vane. - To set the angle of all the vanes, select 'all'. - To set as the factory default settings, select 'standard'. wind angle using 3 Select press button. button, and - The boundary of wind angle settings can be changed to 5 levels or 6 levels according to the product. - When selecting 'standard' for Vane number, the wind angle does not move. the wind angles for the remaining 4 Set vanes as the same as above. ❈ There are products with vanes with no. 1 and no. 2 only according to the product types. Press button to exit. setup, it automatically gets 5 ❈ After out of setup mode if there is no button input for 60 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. button to complete and 6 Press active the setting process. (Airflow direction function will be released whenever setting vane angle) button to exit or 7 Press system will automatically release without any input after 25 seconds. 30 OPERATING INSTRUCTIONS ENGLISH Function Setting - Changing Current Time press function setup 1 Please button. If pressing function setup button repeatedly, it moves to time setup menu. ‘Time setup’ icon is indicated at that time and date blinks at current time indication area. Ex) Changing Current Time as 'Monday / AM 10:20'. 2 Press day. key to adjust the current key to move to AM/ PM setting 3 Press mode (the 'AM/ PM segment will flash). AM/ PM value by 4 Setting pressing button. button to move to 'Hour' 5 Press setting mode. (the 'Hour' segment will flash) Hour value by pressing 6 Setting button. OPERATING INSTRUCTIONS 31 flash) Minute value by pressing 8 Setting button. 9 Press 10 button to finish. In the process, press button to release and exit from setting mode. (In case of exit with incomplete information, it will return to the previous setting) ❈ When exiting without pressing set button, the manipulated value is not reflected. ENGLISH button to move to 'Minute' 7 Press setting mode. (the 'Minute' segment will 32 OPERATING INSTRUCTIONS ENGLISH Programming - Simple Reservation You can set the reservation conveniently in the units of 1 hour from 1 hour to 7 hours. button to enter the 1 Press Programming mode. (the segment flashing) Ex) Setting Simple Reservation time as '3'. 2 Press time. 3 Press button to adjust reservation button to finish setting. button to exit. 4 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. * When simple reservation setup, product automatically runs or stops after the time that is set. OPERATING INSTRUCTIONS 33 ENGLISH Programming - Weekly Reservation You can set the daily reservation in weekly unit. Weekly reservation keeps operating until before you cancel it once you setup. 1 Please move to reservation setup mode by pressing reservation button. ❈ You can setup two weekly reservations for one day, and up to fourteen reservations for a week. For example, to setup (Tuesday morning 11:30 turned on ~ afternoon 12:30 turned off), you setup in order below. move to 'weekly' by 2 Please repeatedly pressing reservation button. 'Weekly' blinks at this time. select weekly reservation or 3 Please weekly reservation ڹڸby using button. ❈ You can setup two reservations, weekly reservation 1 and weekly reservation 2, for a day. move to 'date' setup part by 4 Please using button. If 'date' indication blinks, please setup date. You can setup date from Monday to Sunday. move to 'AM/PM' setup part 5 Please of turning on by using button. move to 'hour' setup part of 6 Please turning on by using button. - It is the part to setup the time at which air-conditioner is turned on. change time by using button. 7 Please - You can setup hour 0~12. 8 Please move to 'minute' setup part of turning on by using 9 If 'minute' indication blinks, please setup 'minute' by using button. button 34 OPERATING INSTRUCTIONS ENGLISH move to 'AM/PM' setup part 10 Please of turning off by using button. - AM/PM setup is identical with turning on time setup. 11 Please move to 'hour' setup part of turning off by using Right button. - It is the part to reserve the time at which air-conditioner is turned off. - If 'hour' indication blinks, please setup 'hour'. ❈ Please setup 'hour' and 'minute' identically with the method to setup turning on time. finishing weekly reservation setup, please press setup/cancellation button. 12 IfWeekly reservation setup for the day that you set is finished. you setup with the method identical with above by selecting the day that 13 Ifyou'd like to setup, it operates weekly reservation. If you setup both turning on reservation time and turning off reservation time identically, it doesn't operate reservation drive. Weekly reservation explanation Reservation number Turning off time Turning on time Under bar: the indication that there is weekly reservation for corresponding day * Indoor unit is turned on to desired temperature if it is configured using up/down button during preset of weekly operation time. - When desired temperature is not set, it is turned on automatically with desired temperature of previous operation. OPERATING INSTRUCTIONS 35 Sleep reservation is the function of air-conditioner to run and stop after certain period of time at sleep mode before sleep. When connected to a ventilation product and set the sleep reservation, when it goes to the sleep mode, after the set time has elapsed. button to enter the 1 Press Programming mode. Ex) Setting Sleep Reservation time as '3'. pressing button to enter the 2 Repeat SLEEP reservation setting mode. ( 3 Press time. segment flashing) button to adjust reservation The SLEEP reservation time is from 1 to 7 hours. button to finish setting. 4 Press Whenever reservation is done. button to exit. 5 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 60 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. - If reservation is setup, 'sleep' indication shows up at the lower part of LCD screen. finishing sleep reservation setup, 6 Ifair-conditioner product operates sleep drive and stops after the time that is set. ! CAUTION Please reserve proper time at sleeping. (Too much air-cooling is not good for your health.) • Because it automatically adjusts desired temperature for comfortable air-cooling at sleep drive, there could be difference between remote controller's desired temperature and air-conditioner body's desired temperature. • Sleep reservation operates as off reservation for the product whose temperature adjustment isn't controlled by unit of 0.5 °C. ENGLISH Programming - Sleep Reservation 36 OPERATING INSTRUCTIONS ENGLISH Programming - ON Reservation Automatically turned On at reserved time that you set. 1 Press button. Ex) Setting ON Reservation Time as 'AM 10:20'. pressing button to 2 Repeat enter the ON reservation setting mode. ( segment flashing) 3 Press setting. button to adjust AM/ PM button to Hour setting 4 Press mode. When the Hour icon flash, please setting time. The setting range is within 1~12. button to shift to Minute 5 Press setting mode. When the Minute icon flash, please setting minute the setting range is within 00~59. 6 Press button to finish setting. OPERATING INSTRUCTIONS 37 setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. - If reservation is set, 'turned on' indication shows up at the lower part of LCD screen, and air-conditioner product runs at the time that is set. - If reservation is cancelled, 'turned on' indication disappears. ENGLISH button to exit. 7 Press ❈ After setup, it automatically gets out of 38 OPERATING INSTRUCTIONS ENGLISH Programming - OFF Reservation Automatically turned Off at reserved time that you set. 1 Press button. Ex) Setting OFF Reservation Time as 'AM 10:20'. pressing button 2 Repeatedly to enter the OFF reservation setting mode. ( segment flashing) 3 Press setting. button to adjust AM/ PM button to shift to Hour 4 Press setting mode. When the Hour icon flash, please setting time. The setting range is within 1~12. button to shift to Minute 5 Press setting mode. When the Minute icon flash, please setting minute the setting range is within 00~59. 6 Press button to finish setting. OPERATING INSTRUCTIONS 39 setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. - If reservation is set, 'turned off' indication shows up at the lower part of LCD screen, and air-conditioner product runs at the time that is set. - If reservation is cancelled, 'turned off' indication disappears. ENGLISH button to exit. 7 Press ❈ After setup, it automatically gets out of 40 OPERATING INSTRUCTIONS ENGLISH Programming - Holiday Reservation It automatically stops at reserved day that you set. press button. 1 Please It enters into reservation setup mode. move to 'holiday' by repeatedly 2 Please pressing button. move to 'date' that 3 Please you want to setup holiday by using button. or cancel holiday by using 4 Pleaseorappointbutton. For example, when you setup Monday/Friday to holiday - 'Monday', 'Friday' letter disappears. press 5 Please holiday setup. button if finishing ❈ If it comes to appointed holiday, air-conditioner automatically stops. Once you setup holiday appointment, until before you cancel holiday setup, air-conditioner automatically stops within one hour even though you run air-conditioner. MAINTENANCE AND SERVICE 41 ENGLISH MAINTENANCE AND SERVICE ! CAUTION Before performing any maintenance, turn off the main power to the system. - Never use any of the followings: Water hotter than 40 °C. Could cause deformation and/or discoloration. Volatile substances. Could damage the surfaces of the air conditioner. Indoor Unit Grille, Case and Remote Control - Turn the system off before cleanining, To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. ! SI B en N N ER z ene S CO U RIN G C LBA R GERG NOTE Supply power must be disconnected before cleaning the indoor unit. 1 Remove the Air filters. - Take hold of the tab and pull slightly forward to remove the filter. ! Air Filters The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if neccessary. CAUTION When the air filter is to be removed, do not touch the metal parts of the indoor unit. It may cause an injury. 2 Clean dirt from the air filter using a vacuum cleaner or washing with water. Air filters Air outlet vent Rack TU chassis : 4EA Rack - If dirt is conspicuous, wash with a neutral detergent in lukewarm water. - If hot water (50 °C or more) is used, it may be deformed. 3 After washing with water, dry well in the shade. - Do not expose the air filter to direct sunlight or heat from a fire when drying it. 4 Install the air filter. 42 MAINTENANCE AND SERVICE ENGLISH Purifying filter(Optional) Cleaning Replacement - Recomended use period : About 2 years 1 Open front panel and remove air filter. The PLASMA filter behind the air filters should be checked and cleaned once every 3 months or more often if necessary. 2 Remove air purifying filter. 1 After removing the air filters, pull slightly 2 3 4 5 forward to remove the PLASMA filter. Dip the PLASMA filter into the water mixed with neutral detergent, for 20~30 minutes. Dry the PLASMA filter in the shade for a day (Especially, the humidity must be removed perfectly on this parts). Note the cuts of electric discharge lines. Re-install the PLASMA filter to the original position. ! CAUTION Don’t touch this PLASMA Filter within 10 seconds after opening the inlet grille, it may cause an electric shock. 3 Insert new air purifying filter. 1 2 4 Reinsert air filter and close front panel. MAINTENANCE AND SERVICE 43 Do not overcool the room. This is not good for the health and wastes electricity. Keep blinds or curtains closed. Do not let direct sunshine enter the room when the air conditioner is in operation. Keep the room temperature uniform. Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room. Make sure that the doors and windows are shut tight. Avoid opening doors and windows as much as possible to keep the cool air in the room. Clean the air filter regularly. Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects. Clean at least once every two weeks. Ventilate the room occasionally. Since windows are kept closed, it is a good idea to open them and ventilate the room now and then. When the air conditioner is not going.... When air conditioner is not going to be used for a long time. 1 Operate the air conditioner at the following settings for 2 to 3 hours. - Type of operation: Fan operation mode. - This will dry out the internal mechanisms. 2 Turn off the breaker. ! CAUTION Turn off the breaker when the air conditioner is not going to be used for a long time. Dirt may collect and may cause a fire. 3 Remove the batteries from the Remote Controller. Helpful information The air filters and your electiric bill. If the air filters become clogged with dust, the cooling capacity will drop, and 6 % of the electricity used to operate the air conditioner will be wasted. When the air conditioner is to be used again. 1 Clean the air filter and install it in the indoor unit. 2 Check that the air inlet and outlet of the indoor/outdoor unit are not blocked. 3 Check that the ground wire is connected correctly. It may be connect to the indoor unit side. ENGLISH Operation Tips! 44 MAINTENANCE AND SERVICE ENGLISH Troubleshooting Tips! Save time and money! Check the following points before requesting repairs or service.... If the malfunction persist, please contact your dealer. Case Explanation The air conditioner does not operate. • Have you made a mistake in timer operation? The room has a peculiar odor. • Check that this is not a damp smell exuded by the walls, carpet, furniture or cloth items in the room. • Has the fuse blown or has the circuit breaker been tripped? It seems that condensation • Condensation occurs when the airflow from the air conditioner cools the is leaking from the air warm room air. conditioner. Air conditioner does not • This is the protector of the mechanism. operate for about 3 minutes • Wait about three minutes and operation will begin. when restart. • Is the air filter dirty? See air filter cleaning instructions. Does not cool or heat effectively. • The room may have been very hot when the room air conditioner was first turned on. Allow time for it to cool down. • Has the setting temperature been set incorrectly? • Are the indoor unit's air inlet or outlet vents obstructed? The air conditioner operation is noisy. • For a noise that sounds like water flowing. -This is the sound of freon flowing inside the air conditioner unit. • For a noise that sounds like the compressed air releasing into atmosphere. -This is the sound of the dehumidifying water being processed inside the air conditioning unit. Crack sound is heard. • This sound is generated by the expansion/contraction of the inlet grille, etc. due to changes of temperature. Remote control display is faint, or no display at all. • Has the circuit breaker been tripped? • Are the batteries inserted in the opposite (+) and (-) directions? The error code is occurred after lightning struck • This product has been applied to the over current protection circuit. Error can occur, but it is normal behavior. After few minutes, It will operate normally. Call the service immediately in the following situations - Anything abnormal such as burning smell, loud noise etc. happen. Stop the unit and turn the breaker off. Never try to repair by yourself or restart the system in such cases. - Main power cord is too hot or damaged. - Error code is generated by self diagnosis. - Water leaks from indoor unit even if the humidity is low. - Any switch, breaker (safety, earth) or fuse fails to work properly User must carry routine checkup & cleaning to avoid unit’s poor performance. In case of special situation, the job must be carried out by service person only.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement