ESPAÑOL FRANÇAIS DEUTSCH ΕΛΛΗΝΙΚΆ
AIR
CONDITIONER
ENGLISH
РУССКИЙ ЯЗЫК УКРАÏНСЬКА ҚАЗАҚ ТІЛІ БЕЛАРУСКАЯ МОВА O‘ZBEK TILI
OWNER’S MANUAL
ČEŠTINA
CEILING CASSETTE, CEILING CONCEALED DUCT
Original instruction
POLSKI
www.lg.com
Copyright © 2016 - 2019 LG Electronics Inc. All Rights Reserved.
LIMBA ROMÂNĂ
[Representative] LG Electronics Inc. EU Representative :
LG Electronics European Shared Service Center B.V.
Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro,
Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA
MFL67870330
Rev.01_030519
NEDERLANDS
Please read this manual carefully before operating your set and
retain it for future reference.
2
TIPS FOR SAVING ENERGY
ENGLISH
TIPS FOR SAVING ENERGY
Here are some tips that will help you minimize the power consumption when you use the air
conditioner. You can use your air conditioner more efficiently by referring to the instructions below:
• Do not cool excessively indoors. This may be harmful for your health and may consume more
electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner
is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the
air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
IMPORTANT SAFETY INSTRUCTIONS
3
The following symbols are displayed on indoor and outdoor units.
Read the precautions in this manual
carefully before operating the unit.
This appliance is filled with
flammable refrigerant (R32)
This symbol indicates that the
Operation Manual should be read
carefully.
This symbol indicates that a service
personnel should be handling this
equipment with reference to the
Installation Manual.
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous
situations and ensure peak performance of your product
! WARNING
It can result in serious injury or death when the directions are
ignored
! CAUTION
It can result in minor injury or product damage when the
directions are ignored. This appliance is intended to be used by
expert or trained users in shops, in light industry and on farms, or
for commercial use by lay persons.
! WARNING
• Always ground the product. There is a risk of electric shock.
• Do not use a defective or underrated circuit breaker. Use the
correctly rated breaker and fuse. There is risk of fire or electric
shock.
• Do not use a multi consent. Always use this appliance on a
dedicated cicuit and breaker.
Otherwise it can cause electric shock or fire.
• For electrical work, contact the dealer, seller, a qualified
electrician, or an Authorized Service Center. Do not
disassemble or repair the product by yourself. There is risk of
fire or electric shock.
• Always ground the product as per the wiring diagram. Do not
connect the ground wire to gas or water pipes lightening rod or
telephone ground wire. There is risk of fire or electric shock.
• Install the panel and the cover of control box securely. There is
risk of fire or electric shock due to dust, water etc.
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
4
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
• Use the correctly rated breaker or fuse. There is risk of fire or
electric shock.
• Do not modify or extend the power cable. If the power cable or
cord has scrathes or skin peeled off or deteriorated then it must
be replaced. There is risk of fire or electric shock.
• For installation, removal or reinstall, always contact the dealer
or an Authorized Service Center. There is risk of fire, electric
shock, explosion, or injury.
• Do not install the product on a defective installation stand. Be
sure that the installation area does not deteriorate with age. It
may cause product to fall.
• Never install the outdoor unit on a moving base or a place from
where it can fall down.
The falling outdoor unit can cause damage or injury or even
death of a person.
• When the product is soaked (flooded or submerged) in water,
contact an Authorized Service Center for repair before using it
again. There is risk of fire or eletric shock.
• Be sure to check the refrigerant to the used. Please read the
label on the product. Incorrect refrigerant used can prevent the
normal operation of the unit.
• Don't use a power cord, a plug or a loose socket which is
damaged.
Otherwise it may cause a fire or electrical shock.
• Do not touch, operate, or repair the product with wet hands.
Hold the plug by hand when taking out. There is risk of electric
shock or fire.
• Do not place a heater or other heating appliances near the
power cable. There is risk of fire and electric shock.
• Do not allow water to run into electric parts. Install the unit away
from water sources. There is risk of fire, failure of the product,
or electric shock.
• Do not store or use or even allow flammable gas or
combustibles near the product. There is risk of fire.
• Indoor/outdoor wiring connections must be secured tightly and
the cable should be routed properly so that there is no force
pulling the cable from the connection terminals. Improper or
IMPORTANT SAFETY INSTRUCTIONS
5
ENGLISH
loose connections can cause heat generation or fire.
• Safely dispose off the packing materials. Like screws, nails,
batteries, broken things etc after installation or svc and then
tear away and thraw away the plastic packaging bags. Children
may play with them and cause injury.
• Make sure to check that the power cable plug is not dirty, loose
or broken and then only insert the plug completely. Dirty, loose
or broken power plug can cause electric shock or fire.
• In outdoor unit the step-up capacitor supplies high voltage
electricity to the electrical components. Be sure to discharge
the capacitor completely before conducting the repair work.
An charged capacitor can cause electrical shock.
• When installing the unit, use the installation kit provided with
the product.
Otherwise the unit may fall and cause severe injury.
• Be sure to use only those parts which are listed in the svc parts
list. Never attempt to modify the equipment. The use of
inappropriate parts can cause an electrical shock, excessive
heat generation or fire.
• Do not use the product in a tightly closed space for a long time.
Perform ventilation regularly. Oxygen deficiency could occur
and hence harm your health.
• Do not open the front grille of the product during operation. (Do
not touch the electrostatic filter, if the unit is so equipped.)
There is risk of physical injury, electric shock, or product failure.
• If strange sounds, smell or smoke comes from product.
Immediately turn the breaker off or disconnect the power supply
cable. There is risk of electric shock or fire.
• Ventilate the product room from time to time when operating it
together with a stove, or heating element etc. Oxygen
deficiency can occur and hence harm your health.
• Turn the main power off and unplug the unit when cleaning or
repairing the product. There is risk of electric shock.
• When the product is not to be used for a long time, disconnect
the power supply plug or turn off the breaker. There is risk of
product damage or failure, or unintended operation.
• Take care to ensure that nobody especially kids could step on
6
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
or fall onto the outdoor unit. This could result in personal injury
and product damage.
• Take care to ensure that power cable could not be pulled out or
damaged during operation. There is risk of fire or electric shock.
• Do not place ANYTHING on the power cable. There is risk of
fire or electric shock.
• Do not plug or unplug the power supply plug to turn the unit
ON/OFF. There is risk of fire or electric shock.
• When flammable gas leaks, turn off the gas and open a window
for ventilation before turn the product on. Do not use the
telephone or turn switches on or off. There is risk of explosion
or fire.
• Do not turn on the breaker or power under condition that front
panel, cabinet, top cover, control box cover are removed or
opened.
Otherwise, it may cause fire, electric shock, explosion or death.
• Use a vacuum pump or Inert (nitrogen) gas when doing leakage
test or air purge. Do not compress air or Oxygen and Do not
use Flammable gases.
Otherwise, it may cause fire or explosion. There is the risk of
death, injury, fire or explosion.
• The appliance shall be stored in a room without continuously
operating ignition sources (for example : open flames, an
operating gas appliance or an operating electric heater.)
• Keep any required ventilation openings clear of obstruction.
• The appliance shall be stored in a well-ventilated area where
the room size corresponds to the room area as specified for
operation. (for R32)
• Ducts connected to an appliance shall not contain an ignition
source. (for R32)
! CAUTION
• Two or more people must lift and transport the product. Avoid
personal injury.
• Do not install the product where it will be exposed to sea wind
(salt spray) directly. It may cause corrosion on the product.
IMPORTANT SAFETY INSTRUCTIONS
7
ENGLISH
• Install the drain hose to ensure that the condensed water is
drained away properly. A bad connection may cause water
leakage.
• Keep level even when installing the product. To avoid vibration
or noise.
• Do not install the product where the noise or hot air from the
outdoor unit could damage or disturb the neighborhoods. It may
cause a problem for your neighbors and hence dispute.
• Always check for gas (refrigerant) leakage after installation or
repair of product. Low refrigerant levels may cause failure of
product.
• Do not use the product for special purposes, such as
preserving foods, works of art, etc. It is a consumer air
conditioner, not a precision refrigeration system. There is risk of
damage or loss of property.
• Do not block the inlet or outlet of air flow. It may cause product
failure.
• Use a soft cloth to clean. Do not use harsh detergents, solvents
or splashing water etc. There is risk of fire, electric shock, or
damage to the plastic parts of the product.
• Do not touch the metal parts of the product when removing the
air filter. There is risk of personal injury.
• Do not step on or put anyting on the product. (outdoor units)
There is risk of personal injury and failure of product.
• Always insert the filter securely after cleaning. Clean the filter
every two weeks or more often if necessary. A dirty filter
reduces the efficiency.
• Do not insert hands or other objects through the air inlet or
outlet while the product is operating. There are sharp and
moving parts that could cause personal injury.
• Be cautious when unpacking and installing the product. Sharp
edges could cause injury.
• If the refrigerant gas leaks during the repair, do not touch the
leakaing refrigerant gas. The refrigernat gas can cause frostbite
(cold burn)
• Do not tilt the unit when removing or uninstalling it. The
condensed water inside can spill.
8
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
• Do not mix air or gas other than the specified refrigerant used in
the system. If air enters the refrigerant system, an excessively
high pressure results, causing equipment damage or injury.
• If the refrigerant gas leaks during the installation, ventilate the
area immediately.
Otherwise it can be harmfull for your health.
• Dismantling the unit, treatment of the refrigerant oil and
eventual parts should be done in accordance with local and
national standards.
• Replace the all batteries in the remote control with new ones of
the same type. Do not mix old and new batteries or different
types of batteries. There is risk of fire or product failure.
• Do not recharge or disassemble the batteries. Do not dispose
off batteries in a fire. They may burn or explode.
• If the liquid from the batteries gets onto your skin or clothes,
wash it well with clean water. Do not use the remote if the
batteries have leaked. The chemicals in batteries could cause
burns or other health hazards.
• If you eat the liquid from the batteries, brush your teeth and see
doctor.
Do not use the remote if the batteries have leaked. The
chemicals in batteries could cause burns or other health
hazard.
• Do not let the air conditioner run for a long time when the
humidity is very high and a door or a window is left open.
Moisture may condense and wet or damage furniture.
• Do not expose your skin or kids or plants to the cool or hot air
draft. This could harm to your health.
• Do not drink the water drained from the product. It is not
sanitary and could cause serious health issues.
• Use a firm stool or ladder when cleaning, maintaining or
repairing the product at an height. Be careful and avoid
personal injury.
• The air conditioner is not intended for use by young children or
invalids without supervision.
• Young children should be supervised to ensure that they do not
play with the air conditioner.
IMPORTANT SAFETY INSTRUCTIONS
9
ENGLISH
• The appliance shall be stored so as to prevent mechanical
damage from occurring.
• Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certificate from an
industry-accredited assessment authority, which authorises
their competence to handle refrigerants safely in accordance
with an industry recognised assessment specification. (for R32)
• Servicing shall only be performed as recommended by the
equipment manufacturer. Maintenance and repair requiring the
assistance of other skilled personnel shall be carried out under
the supervision of the person competent in the use of
flammable refrigerants. (for R32)
• Wear adequate personal protection equipment (PPE) when
installing, maintaining or servicing the product.
• This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
• If the supply cord is damaged, it must be replaced by a special
cord or assembly available from the manufacturer of its service
agent.
• The appliance shall be installed in accordance with national
wiring regulations.
10 TABLE OF CONTENTS
ENGLISH
TABLE OF CONTENTS
2
TIPS FOR SAVING ENERGY
3
IMPORTANT SAFETY INSTRUCTIONS
12 BEFORE USE
12
12
12
12
12
12
About the system
Preparing for operation
Usage
Cleaning and maintenance
Service
Disposal
13 PRODUCT INTRODUCTION
13
13
14
14
15
16
Name and function of parts (CEILING CASSETTE)
Name and function of parts (CEILING CONCEALED DUCT)
Model designation
Operation Indicator Lamp
Wired Remote Controller
Wireless Remote Controller (Accessory)
17 OPERATING INSTRUCTIONS
17
18
18
19
19
20
21
22
23
24
25
25
26
27
28
29
30
Standard Operation - Standard Cooling
Standard Operation - Power Cooling
Standard Operation - Heating Mode
Standard Operation - Dehumidification Mode
Auto Changeover Mode
Standard Operation - Fan Mode
Standard Operation - Auto Operation Mode
Standard Operation - Airflow Setting
Standard Operation - Temperature Setting/Room Temperature Check
Sub Function - Plasma Purification(Accessory)
Sub Function - Comfort Cooling
Function Setting - Child Lock
Function Setting - Change Temp
Function Setting - Elevation Grill(Accessory)
Function Setting - Filter Sign Clear
Function Setting - Vane Angle Control
Function Setting - Changing Current Time
TABLE OF CONTENTS
Programming - Simple Reservation
Programming - Weekly Reservation
Programming - Sleep Reservation
Programming - ON Reservation
Programming - OFF Reservation
Programming - Holiday Reservation
41 MAINTENANCE AND SERVICE
41
42
43
43
44
44
Indoor Unit
Purifying filter(Optional)
Operation Tips!
When the air conditioner is not going....
Troubleshooting Tips! Save time and money!
Call the service immediately in the following situations
ENGLISH
32
33
35
36
38
40
11
12 BEFORE USE
ENGLISH
BEFORE USE
About the system
This system of air conditioner can be used for heating/cooling applications.
Preparing for operation
• Contact an installation specialist for installation.
• Use a dedicated circuit.
Usage
• Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do
not expose occupants, pets, or plants to direct airflow for extended periods of time.
• Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or
other heating devices.
• Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices,
food, pets, plants, and art objects). Such usage could damage the items.
Cleaning and maintenance
• Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling
sharp metal edges.
• Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,
leading to possible electric shock.
• When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a
very high speed during operation. There is a possibility of injury if the unit’s power is accidentally
triggered on while cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
Disposal
The unit uses hydrofluorocarbon. Contact your dealer when discarding this unit. It is required by law to
collect, transport and discard the refrigerant in accordance with the “hydrofluorocarbon collection and
destruction” regulations.
PRODUCT INTRODUCTION 13
Name and function of parts (CEILING CASSETTE)
67
2
1
5
4
3
4
1: Indoor unit
2: Outdoor unit
3: Remote controller
4: Inlet air
5: Discharge air
6: Refrigerant piping, connection electric wire
7: Drain pipe
8: Ground wire
Wire to ground outdoor unit to prevent electrical
8
shocks.
Name and function of parts (CEILING CONCEALED DUCT)
1
4
67
2
5
3
8
1: Indoor unit
2: Outdoor unit
3: Remote controller
4: Inlet air
5: Discharge air
6: Refrigerant piping, connection electric wire
7: Drain pipe
8: Ground wire
wire to ground outdoor unit to prevent electrical
shocks.
ENGLISH
PRODUCT INTRODUCTION
14 PRODUCT INTRODUCTION
ENGLISH
Model designation
- Product Name : Air conditioner
- Model Name :
C
S
15
SQ
N
B
0
Serial number
Chassis name
Indoor Unit / Outdoor Units
N : Indoor Unit
U : Outdoor Unit
Detailed product type for
U- / C- series models
L : Low Static
H : High COP
E : Econo
R : Refrigerant R32
Nominal Capacity
Ex) 7 000 Btu/h Class → '07',
18 000 Btu/h Class → '18'
Product type
T : Ceiling Cassette
B, M : Ceiling Concealed Duct
L : Ceiling Concealed Duct
(Low Static)
V : Ceiling Suspended & floor
Connectable Outdoor unit type
M : Indoor units only for
Multi systems
U : Indoor units only for
Single A systems
C : Common Indoor Unit for
Multi and Single CAC
Operation Indicator Lamp
Lamp
Forced operation Button
Description
Lamp Color
Cooling mode
Green
Heating mode
Green
Time to clean filter in cooling/heating Mode
Yellowish Green
Time to clean filter when product is not operating
Orange
Hot start or defrost mode before starting heating mode
Green
When reservation set on
Yellowish Green
PRODUCT INTRODUCTION 15
ENGLISH
Wired Remote Controller
1
8
7
9
14
2
10
11
12
4
5
13
6
15
3
1
2
3
4
5
6
OPERATION INDICATION SCREEN
SET TEMPERATURE Button
FAN SPEED Button
ON/OFF Button
OPRATION MODE SELECTION Button
WIRELESS REMOTE CONTROLLER
RECEIVER
• Some products don't receive the wireless
signals.
7 AIR FLOW Button
8 SUBFUNCTION Button
9 FUNCTION SETTING Button
10 VENTILATION Button
11 RESERVATION
12 UP,DOWN,LEFT,RIGHT Button
• To check the indoor temperature, press
button.
Please attach the inform label inside of the door.
Please choose proper language depend on your
country.
13 ROOM TEMPERATURE Button
14 SETTING/CANCEL Button
15 ESC Button
* Some functions may not be operated and
displayed depending on the product type.
!
NOTE
• Display temperature can be different from
actual room temperature if the remote
controller is installed at the place where
sun-rays are falling directly or the place
nearby heat source.
• The actual product can be different from
above contents depending upon model
type.
• When using simultaneous operation
system, whenever press remote controller
button, system will approximately operate
after 1~2 minutes.
16 PRODUCT INTRODUCTION
ENGLISH
Wireless Remote Controller (Accessory)
This air-conditioner is equipped with wired remote controller basically. But if you want to be available
with wireless remote controller, you pay for it.
!
NOTE
• The wireless remote controller do not
operate the vane angle control.(4Way
Type)
• For more details refer to the Wireless
Remote Control Accessory manual.
• The actual product can be different from
above contents depending upon model
type.
• The wireless remote controller does not
operate When using simultaneous
operation system.
JET
MODE
* Some functions may not be operated and
displayed depending on the product type.
°C/°F (5 s)
TIME (3 s)
!
CAUTION
CAUTION of handling the Remote Controller
• Aim at the signal receiver on the wired remote controller so as to operate.
• The remote control signal can be received at a distance of up to about 7m.
• Be sure that there are no obstructions between the remote controller and the signal receptor.
• Do not drop or throw the remote controller.
• Do not place the remote controller in a location exposed to direct sunlight, or near the heating unit, or any
other heat source.
• Block a strong light over the signal receptor with a curtain or etc. so as to prevent the abnormal operation.
(ex:electronic quick start, ELBA, inverter type fluorescent lamp)
OPERATING INSTRUCTIONS 17
ENGLISH
OPERATING INSTRUCTIONS
Standard Operation - Standard Cooling
It cools the room by comfortable and clean wind.
1 Press
indoor.
button to turn on the
button to select
2 Press
Cooling operation mode.
the desired temperature
3 Adjust
by pressing
buttons.
Press
button to check the
Room temperature.
When setting the desired
temperature higher than room
temperature, only ventilation
wind is blow out instead of
cooling wind.
18 OPERATING INSTRUCTIONS
ENGLISH
Standard Operation - Power Cooling
It makes the room cool using pleasant and fresh air quickly.
1 Press
indoor.
button to trun on the
button to select
2 Press
cooling operation mode.
button continuously
3 Press
until 'Po' displayed.
What is Power Cooling?
• Desired temperature: Po (actually 18 °C)
It make room temperature
• Wind flow: power wind
drop fast by running
• Wind direction: fix to air-cooling position
h Partial product has no power air-cooling function.
}
Standard Operation - Heating Mode
It supplies warm wind to the indoor.
1 Press
indoor.
button to turn on the
button to select
2 Press
Heating mode.
(To check the indoor temperature,
press the room temperature button.)
the desired temperature
3 Adjust
by pressing
buttons.
When setting the desired
temperature lower than room
temperature, there is only
ventilation wind.
• Heating drive only operates at the cooling and heating model.
• Heating doesn't operate at cooling exclusive model.
OPERATING INSTRUCTIONS 19
It removes humidity while air-cooling weakly.
1 Press
indoor.
button to turn on the
button to select
2 Press
Dehumidification mode.
The temperature setting can not be
adjusted during operation this mode.
the
button to select
3 Press
airflow rate feeble → weak →
medium → strong → automatic.
(The initial wind powerfulness of
humidity removal drive is 'weak'.)
• In rainy season or high humidity climate, it is possible to operate simultaneously dehumidifier
and cooling mode to remove humidity effectively.
• The menu item of wind powerfulness might not be partially selected according to the product.
Auto Changeover Mode
1 Press
indoor.
2
Press
button to turn on the
button to select Auto Changeover Mode.
setting temperature as the right side picture can be set in both
3 The
cooling/ heating model.
ENGLISH
Standard Operation - Dehumidification Mode
20 OPERATING INSTRUCTIONS
ENGLISH
Standard Operation - Fan Mode
It blows the air as it is in the indoor, not the cold wind.
1 Press
indoor.
button to turn on the
2 Press
Mode.
button to select Fan
time pressing
button, you
3 Every
can select wind flow in order of
feeble → weak → medium → strong
→ automatic.
When running ventilation,
compressor of AHU doesn't work.
• Ventilation drive does not release cool wind but general fan
• Because it releases the wind that has no temperature difference from the room, it functions to
circulate the inside air.
• The menu item of wind powerfulness might not be partially selected according to the product.
OPERATING INSTRUCTIONS 21
ENGLISH
Standard Operation - Auto Operation Mode
1 Press
indoor.
button to turn on the
button to select
2 Press
Artificial intelligence Mode.
can adjust
3 You
the temperature
as the picture on
the right for
cooling and
heating model.
the case of
4 For
cooling exclusive,
as the picture on
the right, you can
adjust the
temperature from
hot to cold, from
"-2" to "2" based
on "00".
During operating Auto Operation mode:
• We can use the FAN SPEED button
• We can change manually to other operation mode.
When cold
When cool
When appropriate
When warm
When hot
22 OPERATING INSTRUCTIONS
ENGLISH
Standard Operation - Airflow Setting
Wind powerfulness : You can simply adjust
desired wind powerfulness.
setup desired wind
1 Please
powerfulness by wind powerfulness
button.
• Every time you press wind
powerfulness, you can select the wind flow in
order of ‘feeble → weak → weak medium →
medium → medium strong → strong → power
→ automatic’.
• The menu item might not be partially
selected according to product function.
Wind direction : You can simply adjust desired
wind direction.
1
Please set desired wind direction
by pressing
button.
You can select wind direction of
(comfortable wind → Up/Down
and Right/Left → Right/Left →
Up/Down) by pressing
button.
Partial item of wind directions
might not be selected according
to product function.
* Some functions may not be operated and displayed
depending on the product type.
OPERATING INSTRUCTIONS 23
Temperature Setting
can simply adjust the desired
1 We
temperature.
• Press the
buttons to adjust the
desired temperature.
: Increase 1 ˚C or 2 ˚F per one time
pressing
: Decrease 1 ˚C or 2 ˚F per one time
pressing
• Room temp: Indicate the current room
temperature.
• Set temp: Indicate the temperature
that user want to set.
* Depend on what kind of controller, the
desired temperature can be adjusted
at 0.5 ˚C or 1 ˚F.
Cooling operation:
- The cooling mode doesn't work if
desired temperature is higher than room
temperature Please lower the desired
temperature.
Heating operation:
- The heating mode doesn't work if desired
temperature is lower than room
temperature Please increase the desired
temperature.
Room Temperature Check
press
button, the room
1 Whenever
temperature will be displayed within 5
seconds.
After 5 seconds, it turns to display the
desired temperature.
Because of location of remote controller,
the real room temperature and the this
displayed value can be different
• 5 °C is proper for the difference between room and outside temperature.
ENGLISH
Standard Operation - Temperature Setting/Room Temperature Check
24 OPERATING INSTRUCTIONS
ENGLISH
Sub Function - Plasma Purification(Accessory)
Only products with humidifying function can use this.
The method to setup cleaning air
pressing
1 Repeat
until
icon flash.
button
or cancel Plasma
2 Operate
Purification function by pressing
(
button.
icon appears/disappears on
display part up
to selection )
setting, press
3 After
to exit.
button
❈ After setup, it automatically gets out of setup
mode if there is no button input for 25 seconds.
❈ When exiting without pressing set button, the
manipulated value is not reflected.
• Cleaning air function is additional function and it might not be indicated or operated at the partial
product.
• Cleaning air function is possible only when product is running.
• If you want independent cleaning air drive, please setup cleaning air by pressing additional drive
button at ventilation drive.
* Some functions may not be operated and displayed depending on the product type.
OPERATING INSTRUCTIONS 25
The comfort cooling is the function to automatically control the cooling strength to maintain the pleasant
feeling without turning off the product after the indoor temperature reached the desired temperature.
button repeatedly until
1 Press
Comfort cooling
icon displayed.
on/off Comfort cooling
2 Turn
function by pressing
button.
❈ The icon will be displayed in
case of setting option and
disappear in reverse case.
button after setup.
3 Press
❈ If no button is selected for
about 25 seconds after setup, it
exits the setup mode
button is not selected before
❈ If the
you exit, the changes will not apply.
* Some products may not include Comfort
cooling function.
Function Setting - Child Lock
It is the function to use preventing children or others from careless using.
button repeatedly until
1 Press
the
is flashing.
moving to 'setup' icon area by
2 Ifusing
button, 'setup' icon
blinks, and child lock function is
setup if pressing
button at that
time.
cancelling lock function, if moving
3 When
to 'cancel' icon by pressing
button
and then, pressing
button, child lock
function is cancelled.
button to exit.
4 Press
❈ After setup, it automatically gets out of
setup mode if there is no button input
for 25 seconds.
❈ When exiting without pressing set
button, the manipulated value is not
reflected.
ENGLISH
Sub Function - Comfort Cooling
26 OPERATING INSTRUCTIONS
ENGLISH
Function Setting - Change Temp
Change temperature is the function to setup air-cooling and heating drive automatically changeable
according to the temperature at artificial intelligence drive mode.
1 Repeaticonpressing
flash.
button until
button to change.
2 Press
❈ Converting temp value : 1~7
button to complete
3 Press
and active the setting process.
button to exit or
4 Press
system will automatically release
without any input after 25
seconds.
❈ When exiting without pressing
set button, the manipulated
value is not reflected.
OPERATING INSTRUCTIONS 27
ENGLISH
Function Setting - Elevation Grill(Accessory)
This function is to move the indoor filter up/down for cleaning filter.
button
1 Press
Repeat pressing
button until
icon flash.
to descent using
button
2 Move
and press
button will display
descent icon and the up/down grill will
descent.
up/down grill descents to the
3 When
desired position, move to stop icon
suing
button and press
to stop up/down grill.
button
filter cleaning is finished, fix the
4 When
filter to the up/down grill, move to ascent
icon using
button, and press
button to ascent up/down grill.
button to exit.
5 Press
❈ After setup, it automatically
gets out of setup mode if there
is no button input for 60
seconds.
❈ When exiting without pressing set
button, the manipulated value is not
reflected.
• Elevation grill function only operates in the indoor unit with the elevation grill.
* Some functions may not be operated and displayed depending on the product type.
28 OPERATING INSTRUCTIONS
ENGLISH
Function Setting - Filter Sign Clear
This function is to clear the indicator of indoor filter cleaning.
1 Press
until the
button repeatedly
is flashing.
the
is flashing, press
2 When
the
to clear this display
• When filter is covered by dust, it will reduce cooling/heating efficiency and accumulate more
electric power. Therefore. do clean the filter whenever cleaning time is expired.
* Filter cleaning indication is automatically cancelled without the separate cancellation after certain
period of time.
OPERATING INSTRUCTIONS 29
ENGLISH
Function Setting - Vane Angle Control
This function is to adjust angle at which airflow is blow out.
* Some functions may not be operated and displayed depending on the product type.
pressing
1 Repeat
icon flash.
button until
button to select active vane :
2 Press
1 / 2 / 3 / 4 / All / Standard
Select Vane number using
buttons.
❈ Vane number : No. 1, 2., 3, 4, all, or
standard
- Selected vane is in operation.
- Please verify the operating vane.
- To set the angle of all the vanes,
select 'all'.
- To set as the factory default settings,
select 'standard'.
wind angle using
3 Select
press
button.
button, and
- The boundary of wind angle settings can
be changed to 5 levels or 6 levels
according to the product.
- When selecting 'standard' for Vane
number, the wind angle does not move.
the wind angles for the remaining
4 Set
vanes as the same as above.
❈ There are products with vanes with
no. 1 and no. 2 only according to the
product types.
Press
button to exit.
setup, it automatically gets
5 ❈ After
out of setup mode if there is no
button input for 60 seconds.
❈ When exiting without pressing set
button, the manipulated value is not
reflected.
button to complete and
6 Press
active the setting process.
(Airflow direction function will be
released whenever setting vane angle)
button to exit or
7 Press
system will automatically release
without any input after 25
seconds.
30 OPERATING INSTRUCTIONS
ENGLISH
Function Setting - Changing Current Time
press function setup
1 Please
button. If pressing function setup
button repeatedly, it moves to
time setup menu. ‘Time setup’
icon is indicated at that time and date
blinks at current time indication area.
Ex) Changing Current Time as
'Monday / AM 10:20'.
2 Press
day.
key to adjust the current
key to move to AM/ PM setting
3 Press
mode (the 'AM/ PM segment will flash).
AM/ PM value by
4 Setting
pressing
button.
button to move to 'Hour'
5 Press
setting mode. (the 'Hour' segment will
flash)
Hour value by pressing
6 Setting
button.
OPERATING INSTRUCTIONS 31
flash)
Minute value by pressing
8 Setting
button.
9 Press
10
button to finish.
In the process, press
button to release and exit
from setting mode.
(In case of exit with
incomplete information, it will
return to the previous setting)
❈ When exiting without pressing set
button, the manipulated value is not
reflected.
ENGLISH
button to move to 'Minute'
7 Press
setting mode. (the 'Minute' segment will
32 OPERATING INSTRUCTIONS
ENGLISH
Programming - Simple Reservation
You can set the reservation conveniently in the units of 1 hour from 1 hour to 7 hours.
button to enter the
1 Press
Programming mode.
(the
segment flashing)
Ex) Setting Simple Reservation
time as '3'.
2 Press
time.
3 Press
button to adjust reservation
button to finish setting.
button to exit.
4 Press
❈ After setup, it automatically gets out of
setup mode if there is no button input
for 25 seconds.
❈ When exiting without pressing set
button, the manipulated value is not
reflected.
* When simple reservation setup, product automatically runs or stops after the time that is set.
OPERATING INSTRUCTIONS 33
ENGLISH
Programming - Weekly Reservation
You can set the daily reservation in weekly unit.
Weekly reservation keeps operating until before you cancel it once you setup.
1
Please move to reservation setup mode by pressing reservation button.
❈ You can setup two weekly reservations for one day, and up to fourteen
reservations for a week.
For example, to setup (Tuesday morning 11:30 turned on ~ afternoon 12:30
turned off), you setup in order below.
move to 'weekly' by
2 Please
repeatedly pressing reservation
button. 'Weekly' blinks at this time.
select weekly reservation or
3 Please
weekly reservation ‫ ڹڸ‬by using
button.
❈ You can setup two reservations,
weekly reservation 1 and weekly
reservation 2, for a day.
move to 'date' setup part by
4 Please
using
button. If 'date'
indication blinks, please setup date.
You can setup date from Monday to
Sunday.
move to 'AM/PM' setup part
5 Please
of turning on by using
button.
move to 'hour' setup part of
6 Please
turning on by using
button.
- It is the part to setup the time at
which air-conditioner is turned on.
change time by using
button.
7 Please
- You can setup hour 0~12.
8 Please move to 'minute' setup part of turning on by using
9 If 'minute' indication blinks, please setup 'minute' by using
button.
button
34 OPERATING INSTRUCTIONS
ENGLISH
move to 'AM/PM' setup part
10 Please
of turning off by using
button.
- AM/PM setup is identical with
turning on time setup.
11
Please move to 'hour' setup part
of turning off by using Right
button.
- It is the part to reserve the time
at which air-conditioner is
turned off.
- If 'hour' indication blinks, please
setup 'hour'.
❈ Please setup 'hour' and 'minute'
identically with the method to
setup turning on time.
finishing weekly reservation setup, please press setup/cancellation button.
12 IfWeekly
reservation setup for the day that you set is finished.
you setup with the method identical with above by selecting the day that
13 Ifyou'd
like to setup, it operates weekly reservation.
If you setup both turning on reservation time and turning off reservation time
identically, it doesn't operate reservation drive.
Weekly reservation explanation
Reservation number
Turning off time
Turning on time
Under bar: the indication that there is weekly reservation for
corresponding day
* Indoor unit is turned on to desired temperature if it is configured using up/down button during preset
of weekly operation time.
- When desired temperature is not set, it is turned on automatically with desired temperature
of previous operation.
OPERATING INSTRUCTIONS 35
Sleep reservation is the function of air-conditioner to run and stop after certain period of time at sleep
mode before sleep. When connected to a ventilation product and set the sleep reservation, when it
goes to the sleep mode, after the set time has elapsed.
button to enter the
1 Press
Programming mode.
Ex) Setting Sleep Reservation
time as '3'.
pressing
button to enter the
2 Repeat
SLEEP reservation setting mode.
(
3 Press
time.
segment flashing)
button to adjust reservation
The SLEEP reservation time is from 1 to
7 hours.
button to finish setting.
4 Press
Whenever reservation is done.
button to exit.
5 Press
❈ After setup, it automatically gets out of
setup mode if there is no button input
for 60 seconds.
❈ When exiting without pressing set
button, the manipulated value is not
reflected.
- If reservation is setup, 'sleep'
indication shows up at the lower part
of LCD screen.
finishing sleep reservation setup,
6 Ifair-conditioner
product operates sleep
drive and stops after the time that is set.
!
CAUTION
Please reserve proper time at sleeping. (Too much air-cooling is not good for your health.)
• Because it automatically adjusts desired temperature for comfortable air-cooling at sleep drive,
there could be difference between remote controller's desired temperature and
air-conditioner body's desired temperature.
• Sleep reservation operates as off reservation for the product whose temperature adjustment isn't
controlled by unit of 0.5 °C.
ENGLISH
Programming - Sleep Reservation
36 OPERATING INSTRUCTIONS
ENGLISH
Programming - ON Reservation
Automatically turned On at reserved time that you set.
1 Press
button.
Ex) Setting ON Reservation
Time as 'AM 10:20'.
pressing
button to
2 Repeat
enter the ON reservation
setting mode.
(
segment flashing)
3 Press
setting.
button to adjust AM/ PM
button to Hour setting
4 Press
mode. When the Hour icon flash, please
setting time.
The setting range is within 1~12.
button to shift to Minute
5 Press
setting mode. When the Minute icon
flash, please setting minute the setting
range is within 00~59.
6 Press
button to finish setting.
OPERATING INSTRUCTIONS 37
setup mode if there is no button input
for 25 seconds.
❈ When exiting without pressing set
button, the manipulated value is not
reflected.
- If reservation is set, 'turned on'
indication shows up at the lower part
of LCD screen, and air-conditioner
product runs at the time that is set.
- If reservation is cancelled, 'turned on'
indication disappears.
ENGLISH
button to exit.
7 Press
❈ After setup, it automatically gets out of
38 OPERATING INSTRUCTIONS
ENGLISH
Programming - OFF Reservation
Automatically turned Off at reserved time that you set.
1 Press
button.
Ex) Setting OFF Reservation
Time as 'AM 10:20'.
pressing
button
2 Repeatedly
to enter the OFF reservation
setting mode.
(
segment flashing)
3 Press
setting.
button to adjust AM/ PM
button to shift to Hour
4 Press
setting mode. When the Hour icon flash,
please setting time.
The setting range is within 1~12.
button to shift to Minute
5 Press
setting mode. When the Minute icon
flash, please setting minute the setting
range is within 00~59.
6 Press
button to finish setting.
OPERATING INSTRUCTIONS 39
setup mode if there is no button input
for 25 seconds.
❈ When exiting without pressing set
button, the manipulated value is not
reflected.
- If reservation is set, 'turned off'
indication shows up at the lower part
of LCD screen, and air-conditioner
product runs at the time that is set.
- If reservation is cancelled, 'turned off'
indication disappears.
ENGLISH
button to exit.
7 Press
❈ After setup, it automatically gets out of
40 OPERATING INSTRUCTIONS
ENGLISH
Programming - Holiday Reservation
It automatically stops at reserved day that you set.
press
button.
1 Please
It enters into reservation
setup mode.
move to 'holiday' by repeatedly
2 Please
pressing
button.
move to 'date' that
3 Please
you want to setup holiday
by using
button.
or cancel holiday by using
4 Pleaseorappointbutton.
For example, when you setup
Monday/Friday to holiday
- 'Monday', 'Friday' letter disappears.
press
5 Please
holiday setup.
button if finishing
❈ If it comes to appointed holiday,
air-conditioner automatically stops.
Once you setup holiday appointment,
until before you cancel holiday setup,
air-conditioner automatically stops
within one hour even though you run
air-conditioner.
MAINTENANCE AND SERVICE 41
ENGLISH
MAINTENANCE AND SERVICE
!
CAUTION
Before performing any maintenance, turn off
the main power to the system.
- Never use any of the followings:
Water hotter than 40 °C.
Could cause deformation and/or discoloration.
Volatile substances.
Could damage the surfaces of the air
conditioner.
Indoor Unit
Grille, Case and Remote Control
- Turn the system off before cleanining, To clean,
wipe with a soft, dry cloth. Do not use bleach or
abrasives.
!
SI
B en
N N ER
z ene
S CO
U RIN G
C LBA
R GERG
NOTE
Supply power must be disconnected before
cleaning the indoor unit.
1 Remove the Air filters.
- Take hold of the tab and pull slightly forward
to remove the filter.
!
Air Filters
The air filters behind the front grille should be
checked and cleaned once every 2 weeks or
more often if neccessary.
CAUTION
When the air filter is to be removed, do not
touch the metal parts of the indoor unit.
It may cause an injury.
2 Clean dirt from the air filter using a vacuum
cleaner or washing with water.
Air filters
Air outlet vent
Rack
TU chassis : 4EA Rack
- If dirt is conspicuous, wash with a neutral
detergent in lukewarm water.
- If hot water (50 °C or more) is used, it may
be deformed.
3 After washing with water, dry well in the
shade.
- Do not expose the air filter to direct sunlight
or heat from a fire when drying it.
4 Install the air filter.
42 MAINTENANCE AND SERVICE
ENGLISH
Purifying filter(Optional)
Cleaning
Replacement
- Recomended use period : About 2 years
1 Open front panel and remove air filter.
The PLASMA filter behind the air filters should
be checked and cleaned once every 3 months or
more often if necessary.
2 Remove air purifying filter.
1 After removing the air filters, pull slightly
2
3
4
5
forward to remove the PLASMA filter.
Dip the PLASMA filter into the water mixed
with neutral detergent, for 20~30 minutes.
Dry the PLASMA filter in the shade for a day
(Especially, the humidity must be removed
perfectly on this parts).
Note the cuts of electric discharge lines.
Re-install the PLASMA filter to the original
position.
!
CAUTION
Don’t touch this PLASMA Filter within 10
seconds after opening the inlet grille, it may
cause an electric shock.
3 Insert new air purifying filter.
1
2
4 Reinsert air filter and close front panel.
MAINTENANCE AND SERVICE 43
Do not overcool the room.
This is not good for the health
and wastes electricity.
Keep blinds or curtains
closed.
Do not let direct sunshine enter
the room when the air
conditioner is in operation.
Keep the room temperature
uniform.
Adjust the vertical and
horizontal airflow direction to
ensure a uniform temperature in
the room.
Make sure that the doors
and windows are shut tight.
Avoid opening doors and
windows as much as possible to
keep the cool air in the room.
Clean the air filter regularly.
Blockages in the air filter reduce
the airflow and lower cooling
and dehumidifying effects.
Clean at least once every two
weeks.
Ventilate the room
occasionally.
Since windows are kept closed,
it is a good idea to open them
and ventilate the room now and
then.
When the air conditioner is not
going....
When air conditioner is not going
to be used for a long time.
1 Operate the air conditioner at the following
settings for 2 to 3 hours.
- Type of operation: Fan operation mode.
- This will dry out the internal mechanisms.
2 Turn off the breaker.
!
CAUTION
Turn off the breaker when the air conditioner
is not going to be used for a long time.
Dirt may collect and may cause a fire.
3 Remove the batteries from the Remote
Controller.
Helpful information
The air filters and your electiric bill.
If the air filters become clogged with dust, the
cooling capacity will drop, and 6 % of the
electricity used to operate the air conditioner will
be wasted.
When the air conditioner is to be
used again.
1 Clean the air filter and install it in the indoor
unit.
2 Check that the air inlet and outlet of the
indoor/outdoor unit are not blocked.
3 Check that the ground wire is connected
correctly. It may be connect to the indoor unit
side.
ENGLISH
Operation Tips!
44 MAINTENANCE AND SERVICE
ENGLISH
Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the malfunction persist, please
contact your dealer.
Case
Explanation
The air conditioner does
not operate.
• Have you made a mistake in timer operation?
The room has a peculiar
odor.
• Check that this is not a damp smell exuded by the walls, carpet, furniture or
cloth items in the room.
• Has the fuse blown or has the circuit breaker been tripped?
It seems that condensation
• Condensation occurs when the airflow from the air conditioner cools the
is leaking from the air
warm room air.
conditioner.
Air conditioner does not
• This is the protector of the mechanism.
operate for about 3 minutes
• Wait about three minutes and operation will begin.
when restart.
• Is the air filter dirty? See air filter cleaning instructions.
Does not cool or heat
effectively.
• The room may have been very hot when the room air conditioner was first
turned on. Allow time for it to cool down.
• Has the setting temperature been set incorrectly?
• Are the indoor unit's air inlet or outlet vents obstructed?
The air conditioner
operation is noisy.
• For a noise that sounds like water flowing.
-This is the sound of freon flowing inside the air conditioner unit.
• For a noise that sounds like the compressed air releasing into atmosphere.
-This is the sound of the dehumidifying water being processed inside the air
conditioning unit.
Crack sound is heard.
• This sound is generated by the expansion/contraction of the inlet grille, etc.
due to changes of temperature.
Remote control display is
faint, or no display at all.
• Has the circuit breaker been tripped?
• Are the batteries inserted in the opposite (+) and (-) directions?
The error code is occurred
after lightning struck
• This product has been applied to the over current protection circuit.
Error can occur, but it is normal behavior.
After few minutes, It will operate normally.
Call the service immediately in the following situations
- Anything abnormal such as burning smell, loud noise etc. happen. Stop the unit and turn the breaker
off. Never try to repair by yourself or restart the system in such cases.
- Main power cord is too hot or damaged.
- Error code is generated by self diagnosis.
- Water leaks from indoor unit even if the humidity is low.
- Any switch, breaker (safety, earth) or fuse fails to work properly
User must carry routine checkup & cleaning to avoid unit’s poor performance.
In case of special situation, the job must be carried out by service person only.