advertisement
▼
Scroll to page 2
of
28
Barco n.v. BarcoView MDPW476 ELECTROMAGNETIC INTERFERENCE TEST REPORT (EMI) EVALUATION TEST REPORT NORM : ICES 003 This EMI report includes : Emission (EME) test report : No : BVW-EMC06/526CAN-00 Barco n.v. BarcoView President Kennedypark 35 B-8500 Kortrijk, Belgium Page 1 / 28 EMC Department Report nr: BVW-EMC06/526CAN-00 Performed by DORD Date: 20-Jun-06 UNIT TESTED MDPW476, Serial Nr: Art. Nr: with external power supply 230 Vac 1890057593 K9334220 Name & Function Date Signature Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 2 / 28 EMC Department Report nr: BVW-EMC06/526CAN-00 Performed by DORD Date: 20-Jun-06 UNIT TESTED MDPW476, Serial Nr: Art. Nr: with external power supply 230 Vac 1890057593 K9334220 Norm : ICES 003 (EN 55022) TEST RESULTS EN 55022 LIMIT A : CONDUCTED EMISSION COMPLYING EN 55022 LIMIT A : RADIATED EMISSION COMPLYING EN 61000-3-2 : LIMITS FOR HARMONIC CURRENT EMISSIONS COMPLYING EN 61000-3-3 : LIMITATION OF VOLTAGE FLUCTUATION AND FLICKER COMPLYING Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 3 / 28 Barco n.v. BarcoView REPORT Nr:BVW-EMC06/526CAN-00 Norm : EN 55022 Date : 20-Jun-06 Performed by DORD EMC TEST REPORT MDPW476 230 Vac MDPW476 enclose : Display Ser Nr : Art Nr : 1890057593 K9334220 Barco n.v. BarcoView President Kennedypark 35 B-8500 Kortrijk, Belgium Page 4 / 28 EMC Department Report nr :BVW-EMC06/526CAN-00 Performed by : DORD MEASUREMENT INSTRUMENTATION Date : 20 Jun. 06 SCOPE Computing devices generate radio frequency (RF) energy. This energy is radiated into space or conducted along the power line. This may cause harmful interference in radio communications. The specifications in the EMC tests are set out to reduce the interference potential of the test unit. MEASUREMENT INSTRUMENTATION Instrument MFTR MODEL SERIAL Nr EMI RECEIVER LISN COMPUTER SOFTWARE Ultralog ANTENNA POWER SOURCE 5KVA R&S R&S DELL R&S R&S CALIFORNIA INSTRUMENTS CALIFORNIA INSTRUMENTS BARCO CHROMATICS CALIFORNIA INSTRUMENTS ESI 26 ESH2-Z5 HL 562 5001IX-CTS 838786/0017 871884/0042 100204 54320 PACS-1 72005 GALAXY - - - HARM. & FLICKER COMPUTER SOFTWARE EXTERNAL GENERATOR : Ser Nr: DIGITAL ------------------: PC Galaxy III 033961 Pattern : H. Type NORM : - EN 55022 LIMIT A Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 5 / 28 EMC Department TEST CONFIGURATION Report nr :BVW-EMC06/526CAN-00 Performed by : DORD Date : 01 Sep. 06 TEST CONFIGURATION Item no: Serial : Model: Position 9010 9020 9040 9100 9200 9400 9405 9410 9415 9420 K9334220 1890057593 MDPW476 Component K5031304 K5831302 K5831301 K5031301 K5031302 K5960004 K5031303 K5031305 K5960009 K5432009 Vn : 230 V ac Description ASSY BEZEL MDPW476 G UN SPARTACUS/2 MDP476W UN POWERSUPPLY MDPW476 ASSY MECH. MDPW476 ASSY PACKING MDPW476 CDR UM MDPW476 ASSY FAN MDPW476 ASSY LCD MDPW476 SHEET QUICK SETUP MDPW476 SW DISPLAY V1. MDPW476 Net quantity 1 1 1 1 1 1 1 1 1 1 Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 6 / 28 EMC Department CONDUCTED & RADIATED EMISSIONS TEST Report nr : BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 1.1 SPECIFICATIONS Test Item Type Serial number Reference Documents Test Location Power Frequency Range Input Option Interconnections Contrast & Brightness Date of test Generator : : : : : : MDPW476 1890057593 EN 55022 LIMIT A BarcoView 230 Vac Conduction : from 0.150 MHz to 30 MHz Radiated : from 30 MHz to 3000 MHz : Digital : : : MAX. : 14 June 2006 : PC Galaxy III 1.2 MEASUREMENT RESULTS The Measurement Results are shown in the figures : 1 to 6 Horizontal axis : MHz (logarithmic) Vertical axis : dBuV (linear) dBuV/m (linear) : Conducted Emission : Radiated Emission Figure 1.1 Typical Test Set-up For Conducted Emission Figure 1.2 Typical Test Set-up For Radiated Emission Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 7 / 28 EMC Department CONDUCTED & RADIATED EMISSIONS TEST Report nr : BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 AC DC AC LINE IMPEDANCE STABILISATION NETWORKS ISOLATION TRANSFORMER TEST SAMPLE EMI METER TEST SAMPLE POWER CABLE Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 8 / 28 EMC Department CONDUCTED & RADIATED EMISSIONS TEST Report nr : BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 OR Field measurement equipment Figure 1.2 : Test setup Radiated Emission Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 9 / 28 EMC Department CONDUCTED & RADIATED EMISSIONS TEST Report nr :BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 1.2.1 Conducted Emission : EN 55022 Frequency range from 0.150 MHz to 30 MHz Figure 1 : EUT : ON. Detector : peak Phase : N. Figure 2 : EUT : ON. Detector : Average Phase : N. Figure 3 : EUT : ON. Detector : peak Phase : L. Figure 4 : EUT : ON. Detector : Average Phase : L. 1.2.2 Radiated Emission : EN 55022 Frequency range from 30 MHz to 3 GHz Figure 5: EUT Detector Antenna Turn table : : : : OFF. peak H & V: Automatic Scan 0° Figure 6: EUT Detector Antenna Turn table : : : : ON. peak H & V: Automatic Scan 0° Figure 7: EUT Detector Antenna Turn table : : : : ON. peak H & V: Automatic Scan 90° Figure 8: EUT Detector Antenna Turn table : : : : ON. peak H & V: Automatic Scan 180° Figure 9: EUT Detector Antenna Turn table : : : : ON. peak H & V: Automatic Scan 270° Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 10 / 28 EMC Department Report nr : BVW-EMC06/526CAN-00 Performed by : DORD CONDUCTED & RADIATED EMISSIONS TEST Date : 20 Jun. 06 DSC03554.JPG DSC03556.JPG DSC03555.JPG DSC03557.JPG SET-UP FOR THE MDPW476 EMISSIONS Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 11 / 28 EMC Department CONDUCTED & RADIATED EMISSIONS TEST RESULTS Report nr : BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 Test Information EUT Name: Serial Number: Test Description: Operating Conditions: Operator Name: Comment: MDPW476 1890057593 EN 55022 A & EN 55022 B CE QP 230 V ac 50 Hz DORD 14 June 2006 Phase: N pattern: H gen : GalaxyIII Scan Setup: EN 55022 A & EN55022 B CE QP [EMI conducted] Hardware Setup: Level Unit: Subrange 120kHz - 30MHz CE-LISN-CP3 dBµV Detectors MaxPeak IF Bandwidth 9kHz Meas. Time 0,02s Receiver ESIB 26 EN 55022 A & EN55022 B CE QP 80 EN 55022 Class A Voltage on Mains QP 70 EN 55022 Class B Voltage on Mains QP Level in dBµV 60 50 40 30 20 10 0 150k 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M 20M 30M Frequency in Hz Figure 1 Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 12 / 28 EMC Department CONDUCTED & RADIATED EMISSIONS TEST RESULTS Report nr : BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 Test Information EUT Name: Serial Number: Test Description: Operating Conditions: Operator Name: Comment: MDPW476 1890057593 EN 55022 A & EN 55022 B CE AV 230 V ac 50 Hz DORD 14 June 2006 Phase: N pattern: H gen : GalaxyIII Scan Setup: EN 55022 A & EN55022 B CE AV [EMI conducted] Hardware Setup: Level Unit: Subrange 120kHz - 30MHz CE-LISN-CP3 dBµV Detectors Average IF Bandwidth 9kHz Meas. Time 0,02s Receiver ESIB 26 EN 55022 A & EN55022 B CE AV 80 70 EN 55022 Class A Voltage on Mains AV Level in dBµV 60 EN 55022 Class B Voltage on Mains AV 50 40 30 20 10 0 -10 150k 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M 20M 30M Frequency in Hz Figure 2 Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 13 / 28 EMC Department Report nr : BVW-EMC06/526CAN-00 Performed by : DORD CONDUCTED & RADIATED EMISSIONS TEST RESULTS Date : 20 Jun. 06 Test Information EUT Name: Serial Number: Test Description: Operating Conditions: Operator Name: Comment: MDPW476 1890057593 EN 55022 A & EN 55022 B CE QP 230 V ac 50 Hz DORD 14 June 2006 Phase: L pattern: H gen : GalaxyIII Scan Setup: EN 55022 A & EN55022 B CE QP [EMI conducted] Hardware Setup: Level Unit: Subrange 120kHz - 30MHz CE-LISN-CP3 dBµV Detectors MaxPeak IF Bandwidth 9kHz Meas. Time 0,02s Receiver ESIB 26 EN 55022 A & EN55022 B CE QP 80 EN 55022 Class A Voltage on Mains QP 70 EN 55022 Class B Voltage on Mains QP Level in dBµV 60 50 40 30 20 10 0 150k 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M 20M 30M Frequency in Hz Figure 3 Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 14 / 28 EMC Department CONDUCTED & RADIATED EMISSIONS TEST RESULTS Report nr : BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 Test Information EUT Name: Serial Number: Test Description: Operating Conditions: Operator Name: Comment: MDPW476 1890057593 EN 55022 A & EN 55022 B CE AV 230 V ac 50 Hz DORD 14 June 2006 Phase: L pattern: H gen : GalaxyIII Scan Setup: EN 55022 A & EN55022 B CE AV [EMI conducted] Hardware Setup: Level Unit: Subrange 120kHz - 30MHz CE-LISN-CP3 dBµV Detectors Average IF Bandwidth 9kHz Meas. Time 0,02s Receiver ESIB 26 EN 55022 A & EN55022 B CE AV 80 70 EN 55022 Class A Voltage on Mains AV Level in dBµV 60 EN 55022 Class B Voltage on Mains AV 50 40 30 20 10 0 -10 150k 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M 20M 30M Frequency in Hz Figure 4 Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 15 / 28 EMC Department Report nr : BVW-EMC06/526CAN-00 Performed by : DORD CONDUCTED & RADIATED EMISSIONS TEST RESULTS Date : 20 Jun. 06 Test Information EUT Name: Serial Number: Test Description: Operating Conditions: Operator Name: Comment: MDPW476 1890057593 EN 55022 B & FCC B RE @ 3m / DORD 14 June 2006 Pol: H & V pattern: H gen: Galaxy III Scan Setup: EN 55022 B & FCC B RE 3m 20ms [EMI radiated] Hardware Setup: Level Unit: Subrange 30MHz - 1GHz 1GHz - 3GHz RE-HL562-CP4 dBµV/m Detectors MaxPeak MaxPeak IF Bandwidth 120kHz 120kHz Meas. Time 0,02s 0,02s Receiver ESIB 26 ESIB 26 EN55022 B & FCC B RE turntable inactive 80 EN 55022 A Electric Field Strength 3 m QP EN 55022 B Electric Field Strength 3 m QP 70 Level in dBµV/m 60 50 40 30 20 10 0 30M 50 60 80 100M 200 300 400 500 800 1G 2G 3G Frequency in Hz Figure 5 Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 16 / 28 EMC Department Report nr : BVW-EMC06/526CAN-00 Performed by : DORD CONDUCTED & RADIATED EMISSIONS TEST RESULTS Date : 20 Jun. 06 Test Information EUT Name: Serial Number: Test Description: Operating Conditions: Operator Name: Comment: MDPW476 1890057593 EN 55022 A & EN 55022 B RE @ 3m 230 V ac 50 Hz DORD 14 June 2006 Pol: H & V pattern: H TT: 0° gen: Galaxy III Scan Setup: EN 55022 A & EN 55022 B RE 3m 20ms [EMI radiated] Hardware Setup: Level Unit: Subrange 30MHz - 1GHz 1GHz - 3GHz RE-HL562-CP4 dBµV/m Detectors MaxPeak MaxPeak IF Bandwidth 120kHz 120kHz Meas. Time 0,02s 0,02s Receiver ESIB 26 ESIB 26 EN 55022 A & EN 55022 B RE 80 EN 55022 A Electric Field Strength 3 m QP EN 55022 B Electric Field Strength 3 m QP 70 Level in dBµV/m 60 50 40 30 20 10 0 30M 50 60 80 100M 200 300 400 500 800 1G 2G 3G Frequency in Hz Figure 6 Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 17 / 28 EMC Department Report nr : BVW-EMC06/526CAN-00 Performed by : DORD CONDUCTED & RADIATED EMISSIONS TEST RESULTS Date : 20 Jun. 06 Test Information EUT Name: Serial Number: Test Description: Operating Conditions: Operator Name: Comment: MDPW476 1890057593 EN 55022 A & EN 55022 B RE @ 3m 230 V ac 50 Hz DORD 14 June 2006 Pol: H & V pattern: H TT: 90° gen: Galaxy III Scan Setup: EN 55022 A & EN 55022 B RE 3m 20ms [EMI radiated] Hardware Setup: Level Unit: Subrange 30MHz - 1GHz 1GHz - 3GHz RE-HL562-CP4 dBµV/m Detectors MaxPeak MaxPeak IF Bandwidth 120kHz 120kHz Meas. Time 0,02s 0,02s Receiver ESIB 26 ESIB 26 EN 55022 A & EN 55022 B RE 80 EN 55022 A Electric Field Strength 3 m QP EN 55022 B Electric Field Strength 3 m QP 70 Level in dBµV/m 60 50 40 30 20 10 0 30M 50 60 80 100M 200 300 400 500 800 1G 2G 3G Frequency in Hz Figure 7 Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 18 / 28 EMC Department CONDUCTED & RADIATED EMISSIONS TEST RESULTS Report nr : BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 Test Information EUT Name: Serial Number: Test Description: Operating Conditions: Operator Name: Comment: MDPW476 1890057593 EN 55022 A & EN 55022 B RE @ 3m 230 V ac 50 Hz DORD 14 June 2006 Pol: H & V pattern: H TT: 180° gen: Galaxy III Scan Setup: EN 55022 A & EN 55022 B RE 3m 20ms [EMI radiated] Hardware Setup: Level Unit: Subrange 30MHz - 1GHz 1GHz - 3GHz RE-HL562-CP4 dBµV/m Detectors MaxPeak MaxPeak IF Bandwidth 120kHz 120kHz Meas. Time 0,02s 0,02s Receiver ESIB 26 ESIB 26 EN 55022 A & EN 55022 B RE 80 EN 55022 A Electric Field Strength 3 m QP EN 55022 B Electric Field Strength 3 m QP 70 Level in dBµV/m 60 50 40 30 20 10 0 30M 50 60 80 100M 200 300 400 500 800 1G 2G 3G Frequency in Hz Figure 8 Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 19 / 28 EMC Department CONDUCTED & RADIATED EMISSIONS TEST RESULTS Report nr : BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 Test Information EUT Name: Serial Number: Test Description: Operating Conditions: Operator Name: Comment: MDPW476 1890057593 EN 55022 A & EN 55022 B RE @ 3m 230 V ac 50 Hz DORD 14 June 2006 Pol: H & V pattern: H TT: 270° gen: Galaxy III Scan Setup: EN 55022 A & EN 55022 B RE 3m 20ms [EMI radiated] Hardware Setup: Level Unit: Subrange 30MHz - 1GHz 1GHz - 3GHz RE-HL562-CP4 dBµV/m Detectors MaxPeak MaxPeak IF Bandwidth 120kHz 120kHz Meas. Time 0,02s 0,02s Receiver ESIB 26 ESIB 26 EN 55022 A & EN 55022 B RE 80 EN 55022 A Electric Field Strength 3 m QP EN 55022 B Electric Field Strength 3 m QP 70 Level in dBµV/m 60 50 40 30 20 10 0 30M 50 60 80 100M 200 300 400 500 800 1G 2G 3G Frequency in Hz Figure 9 Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 20 / 28 EMC Department Report nr : BVW-EMC06/526CAN-00 Performed by : DORD LIMITS FOR HARMONIC CURRENT EMISSIONS Date : 20 Jun. 06 Final Measurement Detector 1; Noise measurement Frequency (MHz) 2822.080000 MaxPeak (dBµV/m) Polarity 50.7 Corr. (dB) H Margin (dB) 42.8 Limit (dBµV/m) 3.3 50.0 Final Measurement Detector 1; Turn table position: 0° Frequency (MHz) 92.280000 100.680000 109.080000 201.360000 218.100000 402.720000 1342.000000 1342.120000 1342.840000 2837.020000 MaxPeak (dBµV/m) Polarity 36.3 42.6 41.6 37.2 35.9 42.8 50.2 53.1 48.4 50.5 Corr. (dB) V V V V V V H H H V Margin (dB) 15.3 15.7 16.0 14.5 15.3 21.3 33.6 33.6 33.6 42.9 13.7 7.4 8.4 12.8 14.1 14.2 13.8 10.9 15.6 13.5 Limit (dBµV/m) 50.0 50.0 50.0 50.0 50.0 57.0 64.0 64.0 64.0 64.0 Final Measurement Detector 1; Turn table position: 90° Frequency (MHz) 100.680000 109.080000 1341.820000 1342.660000 2827.180000 2939.740000 MaxPeak (dBµV/m) Polarity 37.8 40.9 50.4 52.4 50.2 50.2 Corr. (dB) V V H H H H Margin (dB) 15.7 16.0 33.6 33.6 42.8 43.5 12.2 9.1 13.6 11.6 13.8 13.8 Limit (dBµV/m) 50.0 50.0 64.0 64.0 64.0 64.0 Final Measurement Detector 1; Turn table position: 180° Frequency (MHz) 100.680000 109.080000 1342.480000 2616.160000 2926.000000 MaxPeak (dBµV/m) Polarity 39.7 41.0 50.1 48.7 49.3 Corr. (dB) V V H V H Margin (dB) 15.7 16.0 33.6 41.4 43.2 10.3 9.0 13.9 15.3 14.7 Limit (dBµV/m) 50.0 50.0 64.0 64.0 64.0 Final Measurement Detector 1; Turn table position: 270° Frequency (MHz) 100.680000 109.080000 2023.180000 2386.540000 2443.000000 2520.700000 2908.720000 MaxPeak (dBµV/m) 37.5 36.0 45.8 45.9 47.3 48.4 49.9 Polarity Corr. (dB) V V H H H V H Margin (dB) 15.7 16.0 38.8 40.0 40.1 41.1 43.4 12.5 14.0 18.2 18.1 16.7 15.6 14.1 Limit (dBµV/m) 50.0 50.0 64.0 64.0 64.0 64.0 64.0 Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 21 / 28 EMC Department LIMITS FOR HARMONIC CURRENT EMISSIONS Report nr : BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 LIMITS FOR HARMONIC CURRENT EMISSIONS 1.1 Specifications Test Item Type Serial number Reference Documents Test Location Power Measurement apparatus Date of test Generator : : : : : : : : MDPW476 1890057593 EN 61000-3-2 BarcoView 230 Vac California Instruments 19 June 2006 pc Galaxy III image: H pattern 1.2 Measurements See page 23 to 25 1.3 Conclusions Class A : The unit is complying DSC03561.JPG Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 22 / 28 EMC Department Report nr : BVW-EMC06/526CAN-00 Performed by : DORD LIMITS FOR HARMONIC CURRENT EMISSIONS Date : 20 Jun. 06 Harmonics – Class-A per A-14(Run time) EUT: MDPW 476 Sn: 1890057593 Tested by: KSTO Test category: Class-A per A-14 (European limits) Test Margin: 100 Test date: 19/06/2006 Start time: 8:56:13 End time: 9:06:23 Test duration (min): 10 Data file name: H-000637.cts_data Comment: generator: PC Galaxy image: H format: 4 MP Customer: BarcoView Test Result: Pass Source qualification: Normal 3 300 2 200 1 100 0 0 -1 -100 -2 -200 -3 -300 Harmonics and Class A limit line Voltage (Volts) Current (Amps) Current & voltage waveforms European Limits Current RMS(Amps) 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 4 Test result: Pass 8 12 16 20 24 Harmonic # 28 32 36 40 Worst harmonic was #20 with 13,49 % of the limit. Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 23 / 28 EMC Department LIMITS FOR HARMONIC CURRENT EMISSIONS Report nr : BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 Current Test Result Summary (Run time) EUT: MDPW 476 Sn: 1890057593 Tested by: KSTO Test category: Class-A per A-14 (European limits) Test Margin: 100 Test date: 19/06/2006 Start time: 8:56:13 End time: 9:06:23 Test duration (min): 10 Data file name: H-000637.cts_data Comment: generator: PC Galaxy image: H format: 4 MP Customer: BarcoView Test Result: Pass Source qualification: Normal Highest parameter values during test: V_RMS (Volts): 230,23 I_Peak (Amps): 1,870 I_Fund (Amps): 0,684 Power (Watts): 154 I_RMS (Amps): 0,762 Crest Factor: 2,519 Power Factor: 0,881 Harm# Harms(avg) 100%Limit %of Limit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 0,117 0,258 0,069 0,056 0,038 0,041 0,028 0,029 0,025 0,022 0,023 0,025 0,018 0,019 0,017 0,019 0,015 0,015 0,015 0,014 0,014 0,013 0,012 0,013 0,011 0,011 0,010 0,010 0,010 0,009 0,009 0,009 0,009 0,009 0,008 0,008 0,008 0,008 0,006 1,080 2,300 0,430 1,440 0,300 0,770 0,230 0,400 0,184 0,330 0,153 0,210 0,131 0,150 0,115 0,132 0,102 0,118 0,092 0,107 0,084 0,098 0,077 0,090 0,071 0,083 0,066 0,078 0,061 0,073 0,058 0,068 0,054 0,064 0,051 0,061 0,048 0,058 0,046 10,8 11,2 16,1 3,9 12,7 5,3 12,1 7,2 13,8 6,8 14,8 11,7 13,6 12,7 14,9 14,3 14,9 12,4 16,8 13,0 16,4 12,9 15,5 14,0 15,3 13,4 15,4 13,0 16,0 12,6 16,5 12,8 16,2 13,2 16,1 13,3 16,3 13,8 12,2 Harms(max) 150%Limit %of Limit Status 0,131 0,272 0,074 0,065 0,045 0,048 0,035 0,033 0,030 0,027 0,025 0,030 0,020 0,022 0,019 0,022 0,018 0,016 0,019 0,017 0,016 0,015 0,013 0,014 0,012 0,012 0,012 0,011 0,012 0,010 0,011 0,010 0,010 0,010 0,010 0,009 0,009 0,009 0,007 1,620 3,450 0,645 2,160 0,450 1,155 0,345 0,600 0,276 0,495 0,230 0,315 0,197 0,225 0,173 0,199 0,153 0,178 0,138 0,161 0,125 0,147 0,115 0,135 0,106 0,125 0,099 0,116 0,092 0,109 0,086 0,102 0,081 0,096 0,077 0,091 0,073 0,087 0,069 8,10 7,90 11,53 3,02 10,09 4,16 10,12 5,49 10,87 5,45 10,83 9,51 10,20 9,86 11,15 11,30 11,54 9,27 13,49 10,49 12,48 10,23 11,41 10,63 11,63 9,92 12,05 9,73 12,54 9,62 12,70 9,84 12,35 10,12 12,66 10,23 12,19 10,87 9,70 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 24 / 28 EMC Department Report nr : BVW-EMC06/526CAN-00 Performed by : DORD LIMITS FOR HARMONIC CURRENT EMISSIONS Date : 20 Jun. 06 Voltage Source Verification Data (Run time) EUT: MDPW 476 Sn: 1890057593 Tested by: KSTO Test category: Class-A per A-14 (European limits) Test Margin: 100 Test date: 19/06/2006 Start time: 8:56:13 End time: 9:06:23 Test duration (min): 10 Data file name: H-000637.cts_data Comment: generator: PC Galaxy image: H format: 4 MP Customer: BarcoView Test Result: Pass Source qualification: Normal Highest parameter values during test: Voltage (Vrms): 230,23 I_Peak (Amps): 1,870 I_Fund (Amps): 0,684 Power (Watts): 154 Harm# 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 I_RMS (Amps): 0,762 Crest Factor: 2,519 Power Factor: 0,881 Harmonics V-rms Limit V-rms % of Limit Status 0,153 0,564 0,054 0,045 0,032 0,027 0,025 0,026 0,023 0,018 0,002 0,002 0,001 0,001 0,007 0,000 0,014 0,001 0,023 0,001 0,008 0,000 0,000 0,005 0,006 0,001 0,001 0,003 0,000 0,000 0,004 0,003 0,000 0,003 0,000 0,004 0,004 0,004 0,017 0,460 2,072 0,460 0,920 0,460 0,690 0,460 0,460 0,460 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 0,230 33,22 27,23 11,65 4,86 6,85 3,87 5,53 5,55 4,97 7,64 0,75 0,81 0,37 0,44 3,23 0,10 6,02 0,50 10,01 0,53 3,30 0,05 0,08 2,22 2,72 0,35 0,44 1,32 0,10 0,06 1,90 1,50 0,15 1,10 0,12 1,94 1,57 1,65 7,40 OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 25 / 28 EMC Department LIMITATION OF VOLTAGE FLUCTUATION AND FLICKER Report nr : BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 LIMITS FOR FLICKER 2.1 Specifications Test Item Type : MDPW476 Serial number : 1890057593 Reference Documents : EN 61000-3-3 Test Location : BarcoView Power : 230 Vac Measurement apparatus : California Instruments Date of test : 20 June 2006 Generator : pc Galaxy III image: H pattern 2.2 Measurements See page 27 2.3 Conclusions The unit is complying DSC03574.JPG Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 26 / 28 EMC Department LIMITATION OF VOLTAGE FLUCTUATION AND FLICKER Report nr : BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 EUT: MDPW476 Sn: 1890057593 Tested by: DORD Test category: All parameters (European limits) Test Margin: 100 Test date: 20/06/2006 Start time: 10:27:44 End time: 10:37:57 Test duration (min): 10 Data file name: F-000639.cts_data Comment: generator: PC GALAXY III image: H format: 4MP Customer: BarcoView Test Result: Pass Status: Test Completed Psti and limit line European Limits 1,00 Pst 0,75 0,50 0,25 0,00 10:37:56 Time is too short for Plt plot Parameter values recorded during the test: Vrms at the end of test (Volt): Highest dt (%): Highest dc (%): Highest dmax (%): Highest Pst (10 min. period): Highest Plt (2 hr. period): 229,93 -0,19 0,00 -0,12 0,026 0,011 Test limit (%): 3,30 Test limit (%): 3,30 Test limit (%): 4,00 Test limit: 1,000 Test limit: 0,650 Pass Pass Pass Pass Pass Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 27 / 28 EMC Department CONCLUSIONS Report nr : BVW-EMC06/526CAN-00 Performed by : DORD Date : 20 Jun. 06 EMC TEST REPORT : REPORT Nr BVW-EMC06/526CAN-00 TEST LIMIT RESULT EN 55022 CONDUCTED EMISSION LIMIT A COMPLYING. EN 55022 RADIATED EMISSION LIMIT A COMPLYING. EN 61000-3-2 LIMITS FOR HARMONIC CURRENT EMISSIONS COMPLYING. EN 61000-3-3 LIMITATION OF VOLTAGE FLUCTUATION AND FLICKER COMPLYING. Barco NV BarcoView, President Kennedypark 35 B-8500 Kortrijk, Belgium Page 28 / 28
advertisement
Related manuals
advertisement