Acnodes KVS801 KVM switch User Manual

Add to my manuals
13 Pages

advertisement

Acnodes KVS801 KVM switch User Manual | Manualzz
All rights reserved. Product description and product specifications are subject to change without notice.
For lastest product information, please v is it Acnodes’ website at www.acnodes.com
14628 Central Ave. Chino, CA 91710
Tel: 909. 597. 7588
© C opyright 2015 Acnodes C orp.
Fax: 909. 597. 1939
Legal Information
First English printing, October 2002
Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness
of the contents. The information in this document is subject to change without notice. We are not liable for any injury or
loss that results from the use of this equipment.
Safety Instructions
Please read all of these instructions carefully before you use the device. Save this manual for
future reference.
■
■
■
■
■
■
■
■
■
■
■
Unplug equipment before cleaning. Don’t use liquid or spray detergent; use a moist cloth.
Keep equipment away from excessive humidity and heat. Preferably, keep it in an air-conditioned environment with
temperatures not exceeding 40º Celsius (104º Fahrenheit).
When installing, place the equipment on a sturdy, level surface to prevent it from accidentally falling and causing
damage to other equipment or injury to persons nearby.
When the equipment is in an open position, do not cover, block or in any way obstruct the gap between it and the
power supply. Proper air convection is necessary to keep it from overheating.
Arrange the equipment’s power cord in such a way that others won’t trip or fall over it.
If you are using a power cord that didn’t ship with the equipment, ensure that it is rated for the voltage and current
labeled on the equipment’s electrical ratings label. The voltage rating on the cord should be higher than the one listed
on the equipment’s ratings label.
Observe all precautions and warnings attached to the equipment.
If you don’t intend on using the equipment for a long time, disconnect it from the power outlet to prevent being
damaged by transient over-voltage.
Keep all liquids away from the equipment to minimize the risk of accidental spillage. Liquid spilled on to the power
supply or on other hardware may cause damage, fire or electrical shock.
Only qualified service personnel should open the chassis. Opening it yourself could damage the equipment and
invalidate its warranty.
If any part of the equipment becomes damaged or stops functioning, have it checked by qualified service personnel.
What the warranty does not cover
■
■
■
Any product, on which the serial number has been defaced, modified or removed.
Damage, deterioration or malfunction resulting from:
Accident, misuse, neglect, fire, water, lightning, or other acts of nature, unauthorized product modification, or
failure to follow instructions supplied with the product.
Repair or attempted repair by anyone not authorized by us.
Any damage of the product due to shipment.
Removal or installation of the product.
Causes external to the product, such as electric power fluctuation or failure.
Use of supplies or parts not meeting our specifications.
Normal wear and tear.
Any other causes which does not relate to a product defect.
Removal, installation, and set-up service charges.
□
□
□
□
□
□
□
□
Regulatory Notices Federal Communications Commission (FCC)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
Any changes or modifications made to this equipment may void the user’s authority to operate this equipment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
■ Re-position or relocate the receiving antenna.
■ Increase the separation between the equipment and receiver.
■ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Contents
< Part 1 > Combo KVM
KVS801
1.1
1.2
1.3
1.4
KVS1601
Package contents
KVM port connection
KVM Cascade
Specifications
P.1
P.2
P.3
P.4
< Part 2 > Usage
2.1
2.2
2.3
2.4
2.5
KVM Button
Password
KVM OSD
KVM Hotkey & Remote Console Hotkey
DC power 12V, 24V, 48V Input
P.5
P.6
P.7
P.8
P.9
Before Installation
■ It is very important to mount the equipment in a suitable cabinet or on a stable surface.
■ Make sure the place has a good ventilation, is out of direct sunlight, away from sources of excessive
dust, dirt, heat, water, moisture and vibration.
Unpacking
The equipment comes with the standard parts shown in package content. Check and make sure they are
included and in good condition. If anything is missing, or damaged, contact the supplier immediately.
Installation for standalone KVM
■
A
B
■
Figure 1.
Screw A: 2 pcs
Screw B: 8 pcs
M3.2 x 4.5 mm
M4 x 10 mm
Install each bracket using screws
provided shown in Figure 1.
Fix the KVM into the rack
Part 1. Combo KVM
< 1.1 > Package Contents
KVS801 / KVS1601
KVM unit
Local Console
Power
•
KVS801 or KVS1601 KVM unit x 1
•
Mounting set w/ bracket & screws x 1
•
Power cord ( for KVM ) x 1
KVS801
Cascade
KVS1601
< 1.2 > KVM port connection
CE-6 / CE-10 / CE-15
¦ 6 / 10 / 15 ft Combo KVM cable
¦ Support PS/2 or USB server
USB Servers
Combo KVM port
PS/2 Servers
Combo KVM cable
support PS/2 or USB server
< 1.3 > KVM Cascade
¦
¦
Cascade up to 8 levels, 128 servers
Cascading multiple KVM with cascade cable.
Cascaded KVMs from level 2 to 8 must be the models of KVS801 / KVS1601.
When multiple combo KVMs cascade together, the master KVM at level 1 will take all control
of other slave KVM switches (e.g. level 2 to 8).
Master KVM
Slave KVM
level 2
To console VG A port
KVS801
Slave KVM
level 3
KVS801
Slave KVM
level 4
KVS801
Slave KVM
KVS801
level 5
Slave KVM
level 6
KVS1601
Slave KVM
level 7
KVS1601
Slave KVM
level 8
KVS1601
CBC-6
¦ 6ft Combo KVM cascade cable
< 1.4 > Specifications
KVS801
¯
¯
¯
KVS1601
KVM Port
Number of ports:
8 or 16
Connector:
Combo connector
Connectivity:
Combo 4-in-1 KVM cable, up to 6, 10 & 15 feet
Local Console
Graphic connector:
1 x VGA
Resolution:
Up to 1600 x 1200
Input device:
2 x USB type A for keyboard & mouse
Management
Multilingual OSD:
English, France, German, Spanish, Italian, Russian, Simplified Chinese,
Japanese
Hotkey combination:
Scroll-lock, Cap-lock, Num-lock, Alt, Ctrl & Win
Security:
Password enable & disable, up to 8 users profile for port access
PC Selection:
Front button, OSD menu & hotkey
¯
Expansion:
Up to 128 servers by 8-level cascade
¯
Compatibility
¯
Multi-platform:
Mix PCs, SUN and Mac G3 / G4 Mac / iMac
Support:
Windows 7 / Vista / 2003 / XP, Linux, Unix
Power
Input:
100 or 240V AC at 50 or 60 Hz via IEC type cord
Option DC:
12V / 24V / 48V DC input
Consumption:
Max. 24 Watt, Standby 5 Watt
¯
Regulatory Approval:
cUL, FCC, CE
¯
Environmental
¯
¯
Operating:
0 to 50°C
Storage:
-5 to 60°C
Relative humidity:
90%, non-condensing
Shock:
50G peak acceleration (11ms, half-sine wave)
Vibration:
58~100Hz / 0.98G (11ms / cycle)
Product Information
Dimension (W x D x H):
443 x 171 x 43.6 mm / 17.4 x 6.7 x 1.72 inch
Net weight:
3 kg / 6.5 lb
Packing Information
Dimension (W x D x H):
500 x 400 x 90 mm / 19.7 x 15.7 x 3.5 inch
Gross weight:
5 kg / 11 lb
Part 2. Usage
2.1 KVM Button
Power ON
¦ Turn off all servers and KVM switches
¦ Make sure all cables / c onnectors are properly connected
¦ Recomm end Power ON sequence is m onitor, KVM switch finally computer
Front Panel - Port LED Indications
8 ports
Bank no.
PC port LEDs
Channel
button
Bank
button
16 ports
Bank no.
7-Segment BANK LED indication
PC port LEDs
Online : Blue LED on indicating a PC is connecting to the port
Active : Green LED on indicating a selected channel
Channel button
Press to selec t channel from 01 to 16
Bank button
Select the bank from 1 to 8
2.2 Password
The password is enabled by default, the default password is “00000000” eight zeros (Do not use “0” on
number pad)
¦ Enable password
1. Press the KVM hotkey Scroll Lock + Scroll Lock + U
2. Logout the KVM by pressing the hotkey Scroll Lock + Scroll Lock + P
3. In SUPERVISOR level, enter “00000000” eight zeros in user name & password field
(Do not use “0” on number pad)
4. In USER level, press Space bar + Enter in user name & password field
Remark: Automatic logout after 10 minutes of inactivity
¦
Set your own user name & password
1. Login the KVM in SUPERVISOR level by pressing “00000000” eight zeros in user name & password
field
2. Call KVM OSD menu by pressing the KVM hotkey Scroll Lock + Scroll Lock + Space Bar
3. Press F1 to the MAIN MENU
4. Select “USER SECURITY”
5. Set password in SUPERVISOR & USER level
a. In the left-top row “S” (SUPERVISOR), press Enter to set your own user name & password
b. In the row 1 to 8 (USER), press Enter to set your own user name & password
6. Press Enter to save the setting or press Esc to cancel the editing without any change
Remark: a. Blank has underscore, while SPACE doesn’t have
b. Press any alphanumeric key to move to next input item. SPACE is treated as a valid
character
¦
Change your password
1. Login the KVM in SUPERVISOR level by pressing your own user name & password
2. Call KVM OSD menu by pressing the KVM hotkey Scroll Lock + Scroll Lock + Space Bar
3. Press F1 to the MAIN MENU
4. Select “USER SECURITY”
5. Change password in SUPERVISOR & USER level
a. In the left-top row “S” (SUPERVISOR), press Enter to change your user name & password
b. In the row 1 to 8 (USER), press Enter to change your user name & password
6. Press Enter to save the setting or press Esc to cancel the editing without any change
Remark: a. Blank has underscore, while SPACE doesn’t have
b. Press any alphanumeric key to move to next input item. SPACE is treated as a valid
character
¦
Disable your password
1. Press the KVM hotkey Scroll Lock + Scroll Lock + U
2. Logout the KVM by pressing the KVM hotkey Scroll Lock + Scroll Lock + P
3. You don’t need user name & password to access the KVM OSD menu
¦
Forget your password
Please contact your supplier for further support
Remark:
¦ You must press the KVM hotkey within 2 seconds
¦ A beep sound will be heard for successful entering KVM hotkey
2.3 KVM OSD
OSD Menu
OSD operation
next to the system name
The PC is powered on
next to the system name
The PC is selected
F1
Access F1 MAIN MENU
F2
Logout the OSD menu
F3
Previous menu
Esc
Cancel / Quit
Enter
Complete / Switch to selected port
Switch to previous or next port
PgUp/PgDn
Switch to previous bank or next bank
1/ 2/3/ 4
Display port 01 ~ 08 / 09 ~ 16 / 17 ~ 24 / 25 ~ 32
Remark: Display port 17 ~ 32 for 32 port model only
F1 Main Menu
01 LANGUAGE
OSD language change
02 PORT NAME EDIT
Define port name
03 PORT SEARCH
Quick searching by port name
04 USER SECURITY
Change password
05 ACCESS LIST
Define user access authority
06 HOTKEY
Change hotkey
07 TIME SETTINGS
Modify scan display time interval
08 OSD MOUSE
Modify OSD mouse speed
2.4 KVM Hotkey & Remote Console Hotkey
Local Console Hotkey
Function
Scroll Lock + Scroll Lock + Space Bar
Calling OSD menu
Right-button mouse + Esc
Calling OSD menu
Scroll Lock + Scroll Lock +
Switch to previous port
Scroll Lock + Scroll Lock +
Switch to next port
Scroll Lock + Scroll Lock +
PgUp / PgDn
Switch to previous bank or next bank
Scroll Lock + Scroll Lock +
Bank no. + Port no.
Switch to specific port
Scroll Lock + Scroll Lock +
B
Turn the buzzer ON and OFF
* Default the buzzer is ON
Scroll Lock + Scroll Lock +
P
Logout the KVM if password security is
ON. Show up the status windows
Advance hotkeys (for Supervisor login only)
Scroll Lock + Scroll Lock +
S
Activate auto-scan mode for connected
servers
*Press any key to exit the auto-scan
mode
Scroll Lock + Scroll Lock +
R
Reset all the KVM settings to factory
default
*Except User Security settings
Scroll Lock + Scroll Lock +
U
Disable and enable password security
*Default security is ON
Scroll Lock + Scroll Lock +
L
To enable / disable the screen saving
function and 10 minutes auto-logout
*Default the screen saving is OFF
Remarks:
¦ Example of “Scroll Lock + Scroll Lock + Bank no. + Port no.”
- Bank No. : 1 to 8
- Port No. : 01 to 16
- e.g. Bank 1 Port 4 : Scroll Lock + Scroll Lock + 1 + 0 + 4
- e.g. Bank 2 Port 16 : Scroll Lock + Scroll Lock + 2 + 1 + 6
¦ You must press the hotkey within 2 seconds
¦ A beep sound will be heard for successful entering
¦ The numeric keypad is not supported, while in OSD screen, the arrow keys, PgUp, PgDn, and Enter keys
are supports
Remote Console Hotkey
Function
Scroll Lock + Scroll Lock +
C
Toggle switch between remote & local port
Scroll Lock + Scroll Lock +
Q
Turn the buzzer ON & OFF
*Default the buzzer is ON
Scroll Lock + Scroll Lock +
S
Activate auto-scan mode for remote & local port
*The scan time interval is 5 seconds
Scroll Lock + Scroll Lock +
A
Auto-adjust the video signal
2.5 DC Power 12V, 24V, 48V Input
Model
12V
24V
48V
Input voltage:
12-Volt
24-Volt
48-Volt
Input range:
9 ~ 18V
18 ~ 36V
36 ~ 75V
Input rating
Input current
- No load
50 mA
50 mA
50 mA
- Full load
4950 mA
2450 mA
1220 mA
Output voltage:
12-Volt
12-Volt
12-Volt
Output current:
4.16A
4.16A
4.16A
Efficiency
84%
85%
85%
Output rating
Remarks:
¦ Package does not include power cord

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

How many KVM ports does the Acnodes KVS801 have?
The KVS801 has 8 combo KVM ports.
What type of connector does the KVM port use?
The KVM port uses a combo connector that supports both PS/2 and USB servers.
What is the maximum resolution supported by the local console?
The local console supports a maximum resolution of up to 1600 x 1200.
What type of input devices does the local console support?
The local console supports 2 x USB type A ports for keyboard and mouse.
Does the KVM switch have any security features?
Yes, the KVM switch has password protection with up to 8 user profiles for port access.
How can I select a PC to control?
You can select a PC to control using the front panel buttons, OSD menu, or hotkeys.
Can I cascade multiple KVM switches together?
Yes, you can cascade up to 8 levels of KVM switches, allowing you to control up to 128 servers.
What type of power input does the KVM switch require?
The KVM switch requires a 100 or 240V AC input at 50 or 60 Hz via an IEC type cord. It also supports optional DC input of 12V / 24V / 48V.
What is the maximum power consumption of the KVM switch?
The maximum power consumption of the KVM switch is 24 Watts, with a standby power consumption of 5 Watts.
What are the operating temperature and humidity ranges for the KVM switch?
The operating temperature range is 0 to 50°C, and the operating humidity range is 90%, non-condensing.
Download PDF

advertisement