Cyberdata 011406 InformaCast® Enabled Loudspeaker Amplifier (AC-Powered) Operations Guide
Add to my manuals106 Pages
advertisement
▼
Scroll to page 2
of 106
The IP Endpoint Company Singlewire InformaCast Loudspeaker Amplifier (AC-Powered) Operations Guide Part #011406 Document Part #931281C for Firmware Version 11.6.3 CyberData Corporation 3 Justin Court Monterey, CA 93940 (831) 373-2601 VoIP V2 Paging Amplifier Operations Guide 931281C Part # 011406 COPYRIGHT NOTICE: © 2016, CyberData Corporation, ALL RIGHTS RESERVED. This manual and related materials are the copyrighted property of CyberData Corporation. No part of this manual or related materials may be reproduced or transmitted, in any form or by any means (except for internal use by licensed customers), without prior express written permission of CyberData Corporation. This manual, and the products, software, firmware, and/or hardware described in this manual are the property of CyberData Corporation, provided under the terms of an agreement between CyberData Corporation and recipient of this manual, and their use is subject to that agreement and its terms. DISCLAIMER: Except as expressly and specifically stated in a written agreement executed by CyberData Corporation, CyberData Corporation makes no representation or warranty, express or implied, including any warranty or merchantability or fitness for any purpose, with respect to this manual or the products, software, firmware, and/or hardware described herein, and CyberData Corporation assumes no liability for damages or claims resulting from any use of this manual or such products, software, firmware, and/or hardware. CyberData Corporation reserves the right to make changes, without notice, to this manual and to any such product, software, firmware, and/or hardware. OPEN SOURCE STATEMENT: Certain software components included in CyberData products are subject to the GNU General Public License (GPL) and Lesser GNU General Public License (LGPL) “open source” or “free software” licenses. Some of this Open Source Software may be owned by third parties. Open Source Software is not subject to the terms and conditions of the CyberData COPYRIGHT NOTICE or software licenses. Your right to copy, modify, and distribute any Open Source Software is determined by the terms of the GPL, LGPL, or third party, according to who licenses that software. Software or firmware developed by CyberData that is unrelated to Open Source Software is copyrighted by CyberData, subject to the terms of CyberData licenses, and may not be copied, modified, reverse-engineered, or otherwise altered without explicit written permission from CyberData Corporation. TRADEMARK NOTICE: CyberData Corporation and the CyberData Corporation logos are trademarks of CyberData Corporation. Other product names, trademarks, and service marks may be the trademarks or registered trademarks of their respective owners. Technical Support The IP Endpoint Company The fastest way to get technical support for your VoIP product is to submit a VoIP Technical Support form at the following website: http://support.cyberdata.net/ Phone: (831) 373-2601, Ext. 333 Email: [email protected] Fax: (831) 373-4193 Company and product information is at www.cyberdata.net. Operations Guide 931281C CyberData Corporation Revision Information Revision 931281C, which corresponds to firmware version 11.6.3, was released on October 31, 2016 and has the following changes: • Updates Figure 2-5, "Using the Amplified Outputs—High Power Mode with One Speaker" • Updates Figure 2-6, "Using the Amplified Outputs—High Power Mode with Two Speakers" • Updates Figure 2-11, "Connections Behind the Port Cover" • Updates Figure 2-12, "Connecting the Strobe" • Updates Figure 2-13, "Connecting the Strobe" Browsers Supported The following browsers have been tested against firmware version 6.5.0: Operations Guide • Internet Explorer (version: 10) • Firefox (also called Mozilla Firefox) (version: 23.0.1 and 25.0) • Chrome (version: 29.0.1547.66 m) • Safari (version: 5.1.7) 931281C CyberData Corporation Pictorial Alert Icons General Alert This pictoral alert indicates a potentially hazardous situation. This alert will be followed by a hazard level heading and more specific information about the hazard. GENERAL ALERT Ground This pictoral alert indicates the Earth grounding connection point. Hazard Levels Danger: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. This is limited to the most extreme situations. Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Caution: Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It may also alert users against unsafe practices. Notice: Indicates a statement of company policy (that is, a safety policy or protection of property). • Operations Guide The safety guidelines for the equipment in this manual do not purport to address all the safety issues of the equipment. It is the responsibility of the user to establish appropriate safety, ergonomic, and health practices and determine the applicability of regulatory limitations prior to use. Potential safety hazards are identified in this manual through the use of words Danger, Warning, and Caution, the specific hazard type, and pictorial alert icons. 931281C CyberData Corporation Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11. Only use attachments/accessories specified by the manufacturer. 12. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 13. Prior to installation, consult local building and electrical code requirements. 14. WARNING: The Singlewire InformaCast Loudspeaker Amplifier enclosure is not rated for any AC voltages! Warning Electrical Hazard: This product should be installed by a licensed electrician according to all local electrical and building codes. GENERAL ALERT Warning Electrical Hazard: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instructions. GENERAL ALERT Warning The PoE connector is intended for intra-building connections only and does not route to the outside plant. GENERAL ALERT Operations Guide 931281C CyberData Corporation Abbreviations and Terms Operations Guide Abbreviation or Term Definition A-law A standard companding algorithm, used in European digital communications systems to optimize, i.e., modify, the dynamic range of an analog signal for digitizing. AVP Audio Video Profile Cat 5 TIA/EIA-568-B Category 5 DHCP Dynamic Host Configuration Protocol LAN Local Area Network LED Light Emitting Diode Mbps Megabits per Second. NTP Network Time Protocol PBX Private Branch Exchange PoE Power over Ethernet (as per IEEE 802.3af standard) RTFM Reset Test Function Management SIP Session Initiated Protocol u-law A companding algorithm, primarily used in the digital telecommunication UC Unified Communications VoIP Voice over Internet Protocol 931281C CyberData Corporation Contents i Chapter 1 Product Overview 1 1.1 How to Identify This Product .....................................................................................................1 1.2 Typical System Installation .......................................................................................................2 1.3 Product Features ......................................................................................................................3 1.4 Supported Protocols .................................................................................................................4 1.5 Supported SIP Servers .............................................................................................................4 1.6 Specifications ...........................................................................................................................5 1.7 Typical Coverage ......................................................................................................................5 1.8 Typical Warehouse Paging Setup .............................................................................................6 Chapter 2 Installing the Singlewire InformaCast Loudspeaker Amplifier 7 2.1 Parts List ..................................................................................................................................7 2.2 Singlewire InformaCast Loudspeaker Amplifier (AC-Powered) Setup ......................................9 2.2.1 NEMA Box Components of the Singlewire InformaCast Loudspeaker Amplifier (ACPowered) ........................................................................................................................10 2.2.2 Connecting the Singlewire InformaCast Loudspeaker Amplifier .................................11 2.2.3 Singlewire InformaCast Loudspeaker Amplifier System Installation and Connection Options ...........................................................................................................................13 2.2.4 Strobe Connections Behind the Port Cover .................................................................15 2.2.5 Connecting the Strobe .................................................................................................16 2.2.6 Singlewire InformaCast Loudspeaker Amplifier Jumpers .............................................18 2.2.7 Ethernet Connection ....................................................................................................18 2.2.8 Loudspeaker Type ........................................................................................................19 2.2.9 Cabling/Wiring ..............................................................................................................19 2.2.10 Confirm Operation ......................................................................................................20 2.2.11 Confirm the IP Address and Test the Audio ...............................................................21 2.2.12 Adjust the Volume ......................................................................................................22 2.3.1 Factory Default Settings ...............................................................................................24 2.3.2 Singlewire InformaCast Loudspeaker Amplifier Web Page Navigation ........................25 2.3.3 Using the Toggle Help Button .......................................................................................26 2.3.4 Log in to the Configuration Home Page .......................................................................28 2.3.5 Configure the Device ....................................................................................................32 2.3.6 Configure the Network Parameters .............................................................................40 2.3.7 Configure the SIP (Session Initiation Protocol) Parameters .........................................43 2.3.8 Configure the Multicast Parameters .............................................................................53 2.3.9 Configure the Sensor Configuration Parameters ..........................................................57 2.3.10 Configure the Audio Configuration Parameters ..........................................................61 2.3.11 Configure the Events Parameters ..............................................................................66 2.3.12 Configure the Autoprovisioning Parameters ...............................................................72 2.4.1 Downloading the Firmware ...........................................................................................84 2.4.2 Reboot the Device ........................................................................................................86 2.5.1 Command Interface Post Commands ..........................................................................87 Appendix A Mounting the Amplifier 91 A.1 Mount the Amplifier ...............................................................................................................91 Appendix B Setting up a TFTP Server 93 B.1 Set up a TFTP Server ............................................................................................................93 B.1.1 In a LINUX Environment ..............................................................................................93 B.1.2 In a Windows Environment .........................................................................................93 Appendix C Troubleshooting/Technical Support 94 C.1 Frequently Asked Questions (FAQ) ........................................................................................94 C.2 Documentation .......................................................................................................................94 C.3 Contact Information ................................................................................................................95 C.4 Warranty and RMA Information ..............................................................................................95 Index Operations Guide 96 931281C CyberData Corporation 1 1 Product Overview The CyberData SIP-enabled Singlewire InformaCast Loudspeaker Amplifier (AC-Powered) (ACPowered) provides an easy method for implementing an IP-based overhead paging system for both new and legacy installations. With up to 25 watts of driving power (802.3at), the Amplifier provides direct drive of a standard Horn speaker and supports a line-out connector for connection to an external amplifier. The interface is compatible with most SIP-based IP PBX servers that comply with the SIP RFC 3261. For non-SIP environments, the Singlewire InformaCast Loudspeaker Amplifier can be configured to listen to multicast address and port number combinations to form paging zones. 1.1 How to Identify This Product To identify the Singlewire InformaCast Loudspeaker Amplifier, look for a model number label similar to the one shown in Figure 1-1. Confirm the following: • The model number on the label should be 011406. Figure 1-1. Model Number Label WWW.CYBERDATA.NET SINGLEWIRE INFORMACAST LOUDSPEAKER AMPLIFIER, AC-POWERED, RoHS COMPLIANT 011406A / 021111H 404000001 Model number Operations Guide 931281C CyberData Corporation Product Overview 2 Typical System Installation 1.2 Typical System Installation Figure 1-2 illustrates how the Singlewire InformaCast Loudspeaker Amplifier is normally installed as part of a public address system. Figure 1-2. Typical Installation Compliant Non-PoE Ethernet Switch SIP Server Loudspeaker Amplifier High Power PoE Injector in Box VoIP Phone Warning Electrical Hazard: The Singlewire InformaCast Loudspeaker Amplifier enclosure is not rated for any AC voltages. GENERAL ALERT Warning Electrical Hazard: This product should be installed by a licensed electrician according to all local electrical and building codes. GENERAL ALERT Warning Electrical Hazard: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instructions. GENERAL ALERT Warning The PoE connector is intended for intra-building connections only and does not route to the outside plant. GENERAL ALERT Operations Guide 931281C CyberData Corporation Product Overview 3 Product Features 1.3 Product Features Singlewire InformaCast Features • Dual registration for Singlewire and SIP • Singlewire Informacast compatibility available. Includes support for Informacast resiliency • Support both SIP and Singlewire InformaCast • InformaCast compliant • InformaCast CK compliant SIP Features Operations Guide • SIP-enhanced interoperability for hosted environments • 9 user-uploadable page messages • Support for security code access for SIP paging • Autoprovisioning via HTTPS • HTTPS web based configuration • Higher Power PoE 802.3AT • 802.11q VLAN tagging • Configurable sense input for use with fault detection • Configurable event generation for device health and status monitoring • Optional direct connect RGB strobe kit connection • Support for G.711 u-law, G.711 a-law, and G.722 codecs • HTTP Command Interface • 10 channel prioritized Multicast ports • Built-in diagnostics • Delayed page support • Cisco SRST • Packaged in a NEMA 3R/IP42-rated enclosure • SIP and Simultaneous Multicast • Dual-speed ethernet 10/100 Mbps • Web-based configuration • PoE 802.3at and 802.3af-enabled • Line-in for background music • Line-out connector • DTMF controlled relay • Direct 8 Ohm speaker drive • User-uploadable tones and messages • Digital and manual volume control • Second SIP endpoint "Night Ringer" • Autoprovisioning • Auto-call voice message from input port sense 931281C CyberData Corporation Product Overview 4 Supported Protocols • Can support two horns 1.4 Supported Protocols The Singlewire InformaCast Loudspeaker Amplifier supports: • SIP • InformaCast Version 4.0 and greater • Multicast • HTTP and HTTPS web-based configuration Provides an intuitive user interface for easy system configuration and verification of Singlewire InformaCast Loudspeaker Amplifier operations. • DHCP Client Dynamically assigns IP addresses in addition to the option to use static addressing. • TFTP Client Facilitates hosting for the configuration file for Autoprovisioning. • RTP • RTP/AVP - Audio Video Profile • SPEEX • Audio Encodings PCMU (G.711 mu-law) PCMA (G.711 A-law) G.722 Packet Time 20 ms 1.5 Supported SIP Servers The following link contains information on how to configure the Singlewire InformaCast Loudspeaker Amplifier for the supported SIP servers: http://www.cyberdata.net/connecting-to-ip-pbx-servers/ Operations Guide 931281C CyberData Corporation Product Overview 5 Specifications 1.6 Specifications Table 1. Specifications Specifications Ethernet I/F 10/100 Mbps Protocol InformaCast and/or SIP (RFC 3261) Power Input PoE 802.3at or 802.3af Audio Output 802.3at - SPL 117 dB @ 1 metera Line In: Input Signal Amplitudes 2.0 VPP maximum Input Impedance 10k Ohm Line Out: Output Signal Amplitudes 2.0 VPP maximum Output Level +2dBm nominal Total Harmonic Distortion 0.5% maximum Output Impedance 10k Ohm Operating Temperature -10o C to 50o C (14o F to 122o F) Payload Types G.711 a-law, G.711 u-law, G.722 Dimensionsb 1.042 in. [26.5 mm] Length 3.295 in. [83.7 mm] Width 7.795 in. [198.0 mm] Height Weight 1.4 lbs. [0.63 kg] Boxed Weight 2.0 lbs. [0.90 kg] Part Number 011406 Loudspeaker Part Number 011068 a.When used with the 011068 Mini Horn. b. Dimensions are measured from the perspective of the product being upright with the front of the product facing you. 1.7 Typical Coverage With one horn attached to Paging Amplifier under standard 802.3af PoE power, coverage is up to 5,000 square feet. With two horns attached to the Paging Amplifier under 802.3at PoE (high power), coverage is up to 10,000 square feet depending on ambient background noise levels. Operations Guide 931281C CyberData Corporation Product Overview 6 Typical Warehouse Paging Setup 1.8 Typical Warehouse Paging Setup Figure 1-3. Typical Warehouse Paging Setup Loud Speaker Amplifier Part Numbers: 011404 and 011405 "High Power Mode" with Two (2) Horn Speakers Attached Horn Speaker Horn Speaker Horn Speaker Horn to Loud Speaker Amplifier 25' 25' Horn Speaker Loud Speaker Amplifier Horn Speaker Horn Speaker to Horn Speaker 50' Horn Speaker Office Bathroom Typical Example of a 70,000 Square Feet Warehouse Paging Set up Operations Guide 931281C CyberData Corporation 7 2 Installing the Singlewire InformaCast Loudspeaker Amplifier 2.1 Parts List Table 2-1 illustrates the parts for each Singlewire InformaCast Loudspeaker Amplifier and includes a kit for mounting. Table 2-1. Parts List Operations Guide Quantity Part Name 1 Singlewire InformaCast Loudspeaker Amplifier Assembly 1 Enclosure 1 Installation Quick Reference Guide 1 PoE Power Injector 1 CAT 5e/CAT6 cable 1 Ground Wire 931281C Illustration CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 8 Table 2-1. Parts List (continued) Quantity Part Name 1 Mounting Accessory Kit which includes: Illustration (3) Plastic Ribbed Anchors (3) #8 Sheet Metal Screws 151147 #8x1.25" Truss Head Phillips Sheet Metal Screw (3x) 531032 Plastic Ribbed Anchor (3x) Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 9 2.2 Singlewire InformaCast Loudspeaker Amplifier (ACPowered) Setup Set up and configure each Singlewire InformaCast Loudspeaker Amplifier before you mount it. CyberData delivers each Singlewire InformaCast Loudspeaker Amplifier with the factory default values indicated in Table 2-2: Table 2-2. Factory Default Settings—Default of Network Parameter Factory Default Setting IP Addressing DHCP a IP Address 10.10.10.10 Web Access Username admin Web Access Password admin Subnet Mask a 255.0.0.0 a 10.0.0.1 Default Gateway a. Default if there is not a DHCP server present. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 10 NEMA Box Components of the Singlewire InformaCast Loudspeaker Amplifier (AC-Powered) 2.2.1 NEMA Box Components of the Singlewire InformaCast Loudspeaker Amplifier (AC-Powered) Figure 2-4 shows all of the NEMA box components of the Singlewire InformaCast Loudspeaker Amplifier (AC-Powered). Figure 2-4. Loudspeaker Amplifier Components—AC powered RTFM Switch PoE Injector Data and Power Out Data In Ethernet Connection Speaker Connection LEDs Volume AC power Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 11 Connecting the Singlewire InformaCast Loudspeaker Amplifier 2.2.2 Connecting the Singlewire InformaCast Loudspeaker Amplifier 2.2.2.1 Using the Amplified Outputs High Power Mode The following figure illustrate how to connect the Singlewire InformaCast Loudspeaker Amplifier and (One Speaker) use the amplified outputs in high power mode to one speaker or horn. Figure 2-5. Using the Amplified Outputs—High Power Mode with One Speaker *Note: Horn is connected to terminal block pins 9 (-) and 12 (+) of the paging amplifier for mono mode. CLASS II WIRING Non-PoE Ethernet Switch Cat 5 Ethernet Cable *Note: This AC connection needs to be installed by a certified electrician. ~ Mono(+)/Left Spkr (+) - 12 Left Spkr (-) - 11 Right Spkr (+) - 10 Mono(-)/Right Spkr (-) - 9 Line-Out (+) - 8 Line-Out (-) - 7 Line-In (-) - 6 Line-In (+) - 5 Relay COM - 4 Relay NO/NC - 3 Door Sense/Button Common (GND) - 2 Door Sense/Button Contact (+) - 1 + Note: You can use an 802.3at compliance switch instead of an 802.3at power injector and hub. *+ AC Input* *Note: The positive (+) wire coming from the speaker may be red or white. The negative (-) wire is black. *Note: Maximum recommended length of the horn should be 50 feet from the amplifier. Standard 1 Speaker Configuration (802.3at mode) 8 Ohms *Note: Use 16 gauge wire coming out of screw terminals. 16 gauge wire Twist wire nuts + Note: Use wire nuts to connect wire from the speakers to 16 gauge wire. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 12 Connecting the Singlewire InformaCast Loudspeaker Amplifier High Power Mode The following figure illustrate how to connect the Singlewire InformaCast Loudspeaker Amplifier and (Two Speakers) use the amplified outputs in high power mode to two speakers or horns. Figure 2-6. Using the Amplified Outputs—High Power Mode with Two Speakers *Note: Horn is connected to terminal block pins 9 (-) and 12 (+) of the paging amplifier for mono mode. Mono(+)/Left Spkr (+) - 12 Left Spkr (-) - 11 Right Spkr (+) - 10 Mono(-)/Right Spkr (-) - 9 Line-Out (+) - 8 Line-Out (-) - 7 Line-In (-) - 6 Line-In (+) - 5 Relay COM - 4 Relay NO/NC - 3 Door Sense/Button Common (GND) - 2 Door Sense/Button Contact (+) - 1 CLASS II WIRING + Non-PoE Ethernet Switch Cat 5 Ethernet Cable *Note: This AC connection needs to be installed by a certified electrician. ~ AC Input* *Note: The positive (+) wire coming from the speaker may be red or white. The negative (-) wire is black. *+ Use 16 gauge wire coming out of screw terminals. Note: Make sure that the wire length going to the wire nuts is kept short (approximately 6 inches). Optional 2 Speaker Configuration (802.3at mode) 8 Ohms *Note: Maximum recommended length of each horn should be 25 feet from the amplifier. Standard 1 Speaker Configuration (802.3at mode) 8 Ohms 16 gauge wire + + Twist wire nuts 2 speakers in parallel (4 Ohm total) Note: Use wire nuts to connect wire from the speakers to 16 gauge wire. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 13 Singlewire InformaCast Loudspeaker Amplifier System Installation and Connection Options 2.2.3 Singlewire InformaCast Loudspeaker Amplifier System Installation and Connection Options The following figures show the connection options for the Singlewire InformaCast Loudspeaker Amplifier. Figure 2-7. Singlewire InformaCast Loudspeaker Amplifier Connections CLASS II WIRING Mono(+)/Left Spkr (+) - 12 Left Spkr (-) - 11 Right Spkr (+) - 10 Mono(-)/Right Spkr (-) - 9 Line-Out (+) - 8 Line-Out (-) - 7 Line-In (-) - 6 Line-In (+) - 5 Relay COM - 4 Relay NO/NC - 3 Door Sense/Button Common (GND) - 2 Door Sense/Button Contact (+) - 1 Speaker Connections (Figure 2-5)(Figure 2-6) Line-Out Connection (10K Ohm) Line-In Connection (Figure 2-8) Relay Connection (Figure 2-9) Sensor Connection (Figure 2-10) Figure 2-8. Line-In Connection When line-in is enabled on the device, the audio received from the line-in connection will be played to the speaker(s) and lineout connection as the lowest priority audio. Loudspeaker Amplifier Music Source Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 14 Singlewire InformaCast Loudspeaker Amplifier System Installation and Connection Options Figure 2-9. Relay or LED Strobe Connection When the device is called from a remote phone, the relay on the device can be programmed to blink and drive an LED Strobe Light. External device such as an electric door strike or an LED Strobe Light AC or DC Power Source High PIV Ultrafast Switching Diode Solid State or Mechanical Relay OUT IN Output Contacts AC or DC-rated depending upon controlled device requirements DC Power Supply (Max. 30 VDC @ 1A) Figure 2-10. Sensor Connection Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 15 Strobe Connections Behind the Port Cover 2.2.4 Strobe Connections Behind the Port Cover See Figure 2-11 for the additional connection options for the Singlewire InformaCast Loudspeaker Amplifier. Figure 2-11. Connections Behind the Port Cover CLASS II WIRING MIC IN 3 2 1 STROBE 5 4 3 2 1 See Table 2-3 for the descriptions of the connections behind the port cover. Table 2-3. Connections Behind the Port Cover Microphone Connections Name MIC IN Connection Description J6-1 Microphone chassis ground connections J6-2 Microphone signal input J6-3 Microphone common input Connection Description J9-1 Ground J9-2 Strobe positive power (+24V) J9-3 Ground J9-4 I2C data J9-5 I2C clock Strobe Connections Name STROBE Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 16 Connecting the Strobe 2.2.5 Connecting the Strobe 1. Remove the three mounting screws to remove the AC panel cover. See Figure 2-12. 2. Insert the power cord and network cable through the rubber grommets at the bottom of the enclosure. See Figure 2-12. 3. Connect the power cord and ground wires to a 125VAC Outlet or universal receptacle on the back of the AC panel cover. See Figure 2-12. 4. Connect a network cable to the power injector. See Figure 2-12. Figure 2-12. Connecting the Strobe Network Cable to Power Injector. Stripe & Tin Wires 0.4" [10mm] Power Cord Network Cable AC PANEL COVER Network Cable Rubber Grommets Paging Amplifier Removed to Show Cable Exit Note: Power Cord and Network Cable are Not Included. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 17 Connecting the Strobe 5. Remove the mounting screw to remove the cover plate. See Figure 2-13. 6. Remove the hole plug and grommet. See Figure 2-13. 7. Slide the cover plate through the slot on the cable grommet. See Figure 2-13. 8. Install the mounting screw to secure the cover plate. See Figure 2-13. Figure 2-13. Connecting the Strobe Strobe Cable Kit (Part of RGB Strobe) Back Plate Mounting Screw Cable Grommet Hole Plug & Grommet Mounting Screw Slot Slot J1 to STROBE Cover Plate 011288 Auxiliary RGB Strobe Kit RGB Strobe STROBE MIC IN Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 18 Singlewire InformaCast Loudspeaker Amplifier Jumpers 2.2.6 Singlewire InformaCast Loudspeaker Amplifier Jumpers See Figure 2-14 for the jumper locations. Figure 2-14. Jumper Locations JP4 JP2 JP3 JP5 JP1 See Table 2-4 for the jumper descriptions. Table 2-4. Jumper Descriptions Jumper Description JP1 Reset—Factory Only JP2 RTFM (not installed) JP3 Audio Enable Jumper—Factory Only JP4 Relay NO/NC (default to NO)—Factory Only JP5 PoE IEEE 802.3at—Factory Only 2.2.7 Ethernet Connection See Table 2-5 for details about the Singlewire InformaCast Loudspeaker Amplifier connection. Table 2-5. Singlewire InformaCast Loudspeaker Amplifier Connection Operations Guide Connection Connection Details Location Ethernet Use a RJ 45 cable. Singlewire InformaCast Loudspeaker Amplifier (ACPowered) 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 19 Loudspeaker Type 2.2.8 Loudspeaker Type Using the amplified output, the CyberData Singlewire InformaCast Loudspeaker Amplifier supports the 011068 Loudspeaker or equivalent unamplified loudspeaker. Figure 2-15. 011068 Loudspeaker 2.2.9 Cabling/Wiring Using the amplified output, you may connect a 011068 loudspeaker or equivalent unamplified speaker to a Singlewire InformaCast Loudspeaker Amplifier with good quality speaker wire that is 16 gauge and limited to 25 feet in length with two loudspeakers or 50 feet in length with one loudspeaker. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 20 Confirm Operation 2.2.10 Confirm Operation After connecting the device to the 802.3af compliant ethernet hub, use the LEDs on the device to confirm that the device is operational and linked to the network. Table 2-6. Singlewire InformaCast Loudspeaker Amplifier LEDs LED Color Function Power (PWR) BLUE/GREEN The 802.3at power injector that is provided with the device should cause the Power (PWR) LED to illuminate BLUE to indicate that high power is available. The Power (PWR) LED may illuminate GREEN if a low power mode (802.3af) power source is used (not included and sold separately). GREEN Status After supplying power to the device, a steady GREEN Status LED illuminates. After about 20 seconds, the GREEN Status LED will blink fast to indicate that the device is acquiring an IP address and attempting to autoprovision. The GREEN Status LED will turn off thereafter until the device has finished booting. When the device has fully booted, the GREEN Status LED will turn on solid to confirm the device is operational. The GREEN Status LED will blink during a page when it is online. Speed (SPD) AMBER The Speed (SPD) LED illuminates AMBER for a 100Mb link or is off for 10MB when the network link to the device is established. Link/Activity (Link/Act.) GREEN The Link/Activity (Link/Act.) GREEN LED blinks to indicate network traffic. Figure 2-16. Singlewire InformaCast Loudspeaker Amplifier LEDs Volume Speed (SPD) LED (AMBER) Power (PWR) LED (BLUE/GREEN) Operations Guide SPD Link/Act PWR 931281C Status Link/Activity (Link/Act.) LED (GREEN) Status LED (GREEN) CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 21 Confirm the IP Address and Test the Audio 2.2.11 Confirm the IP Address and Test the Audio 2.2.11.1 RTFM Switch When the Singlewire InformaCast Loudspeaker Amplifier is operational and linked to the network, use the Reset Test Function Management (RTFM) switch (Figure 2-17) on the Singlewire InformaCast Loudspeaker Amplifier face to announce and confirm the Singlewire InformaCast Loudspeaker Amplifier’s IP Address and test the audio to verify that it is working. Figure 2-17. RTFM Switch RTFM switch Announcing the IP To announce a Singlewire InformaCast Loudspeaker Amplifier’s current IP address: Address • Press and hold the RTFM switch for a couple of seconds and then release it. Caution GENERAL ALERT Restoring the Factory Default Settings Equipment Caution: Pressing and holding the RTFM switch for more than five seconds will restore the device to the factory default settings. See the “Restoring the Factory Default Settings” section. To restore the factory default settings, complete the following steps: 1. Press and hold the RTFM switch until you hear the device announce the words, “restoring defaults” and “rebooting”. 2. Release the RTFM switch. The device will be restored to the factory default settings. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 22 Adjust the Volume 2.2.12 Adjust the Volume There are two ways to adjust the volume for the Singlewire InformaCast Loudspeaker Amplifier: • The SIP Volume setting on the Device Configuration Page • The external Volume dial (Figure 2-19) on the Singlewire InformaCast Loudspeaker Amplifier face Figure 2-18. External Volume Dial Volume SPD Link/Act External volume dial PWR Status 2.2.12.1 The SIP Volume Setting To adjust the volume of the device with the SIP Volume setting on the Device Configuration Page, complete the following steps: 1. Go to the Home Page. 2. Select the Device Configuration Page page. 3. In the SIP Volume box, type a number between 0 (lowest) and 9 (highest). 4. Select Save. 2.2.12.2 The Multicast Volume Setting To adjust the Multicast Volume volume with the Multicast Volume setting on the Device Configuration Page, complete the following steps: 1. Go to the Home Page. 2. Select the Device Configuration Page. 3. In the Multicast Volume box, type a number between 0 (lowest) and 9 (highest). 4. Select Save. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 23 Adjust the Volume 2.2.12.3 The Ring Volume Setting To adjust the Ring Volume volume with the Ring Volume setting on the Device Configuration Page, complete the following steps: 1. Go to the Home Page. 2. Select the Device Configuration Page. 3. In the Multicast Volume box, type a number between 0 (lowest) and 9 (highest). 4. Select Save. 2.2.12.4 The Sensor Volume Setting To adjust the Sensor Volume volume with the Sensor Volume setting on the Device Configuration Page, complete the following steps: 1. Go to the Home Page. 2. Select the Device Configuration Page. 3. In the Sensor Volume box, type a number between 0 (lowest) and 9 (highest). 4. Select Save. 2.2.12.5 External Volume Dial To adjust the Singlewire InformaCast Loudspeaker Amplifier volume with the external volume dial, complete the following steps: 1. Turn the external Volume dial (Figure 2-18) on the Singlewire InformaCast Loudspeaker Amplifier face. Note For the lineout volume, the volume is fixed and the volume control is adjusted through an external amplifier. Figure 2-19. External Volume Dial Volume SPD Link/Act External volume dial PWR Operations Guide 931281C Status CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 24 Factory Default Settings 2.3 Configure the Singlewire InformaCast Loudspeaker Amplifier Parameters To configure the Singlewire InformaCast Loudspeaker Amplifier online, use a standard web browser. Configure each Singlewire InformaCast Loudspeaker Amplifier and verify its operation before you mount it. When you are ready to mount an Singlewire InformaCast Loudspeaker Amplifier, refer to Appendix A, "Mounting the Intercom" for instructions. 2.3.1 Factory Default Settings All Singlewire InformaCast Loudspeaker Amplifiers are initially configured with the following default IP settings: When configuring more than one Singlewire InformaCast Loudspeaker Amplifier, attach the Singlewire InformaCast Loudspeaker Amplifiers to the network and configure one at a time to avoid IP address conflicts. Table 2-7. Factory Default Settings Parameter Factory Default Setting IP Addressing DHCP IP Addressa 10.10.10.10 Web Access Username admin Web Access Password admin Subnet Mask a Default Gatewaya 255.0.0.0 10.0.0.1 a. Default if there is not a DHCP server present. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 25 Singlewire InformaCast Loudspeaker Amplifier Web Page Navigation 2.3.2 Singlewire InformaCast Loudspeaker Amplifier Web Page Navigation Table 2-8 shows the navigation buttons that you will see on every Singlewire InformaCast Loudspeaker Amplifier web page. Table 2-8. Web Page Navigation Web Page Item Description Link to the Home page. Link to the Device page. Link to the Network page. Link to go to the SIP page. Link to the Multicast page. Link to the Sensor page. Link to the Audiofiles page. Link to the Events page. Link to the Autoprovisioning page. Link to the Firmware page. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 26 Using the Toggle Help Button 2.3.3 Using the Toggle Help Button The Toggle Help button allows you to see a short description of some of the settings on the webpage. To use the Toggle Help button, do the following: 1. Click on the Toggle Help button that is on the UI webpage. See Figure 2-20 and Figure 2-21. Figure 2-20. Toggle/Help Button 2. You will see a question mark ( ) appear next to each web page item that has been provided with a short description by the Help feature. See Figure 2-21. Figure 2-21. Toggle Help Button and Question Marks Question mark appears next to the web page items Toggle Help button Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 27 Using the Toggle Help Button 3. Move the mouse pointer to hover over the question mark ( page item will appear. See Figure 2-22. ), and a short description of the web Figure 2-22. Short Description Provided by the Help Feature Question mark Operations Guide 931281C A short description of the web page item will appear CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 28 Log in to the Configuration Home Page 2.3.4 Log in to the Configuration Home Page 1. Open your browser to the Singlewire InformaCast Loudspeaker Amplifier IP address. Note If the network does not have access to a DHCP server, the device will default to an IP address of 10.10.10.10. Note Make sure that the PC is on the same IP network as the Singlewire InformaCast Loudspeaker Amplifier. Note You may also download CyberData’s VoIP Discovery Utility program which allows you to easily find and configure the default web address of the CyberData VoIP products. CyberData’s VoIP Discovery Utility program is available at the following website address: http://www.cyberdata.net/assets/common/discovery.zip Note The device ships in DHCP mode. To get to the Home page, use the discovery utility to scan for the device on the network and open your browser from there. 2. When prompted, use the following default Web Access Username and Web Access Password to access the Home Page (Figure 2-23): Web Access Username: admin Web Access Password: admin Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 29 Log in to the Configuration Home Page Figure 2-23. Home Page 406100001 v11.6.3 Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 30 Log in to the Configuration Home Page 3. On the Home page, review the setup details and navigation buttons described in Table 2-9. Note The question mark icon ( ) in the following table shows which web page items will be defined after the Toggle Help button is pressed. Table 2-9. Home Page Overview Web Page Item Description Admin Settings Username The username to access the web interface. Enter up to 25 characters. Password The password to access the web interface. Enter up to 25 characters. Confirm Password Confirm the web interface password. Current Status Serial Number Shows the device serial number. Mac Address Shows the device Mac address. Firmware Version Shows the current firmware version. IP Addressing Shows the current IP addressing setting (DHCP or static). IP Address Shows the current IP address. Subnet Mask Shows the current subnet mask address. Default Gateway Shows the current default gateway address. DNS Server 1 Shows the current DNS Server 1 address. DNS Server 2 Shows the current DNS Server 2 address. SIP Mode Shows the current status of the SIP mode. Multicast Mode Shows the current status of the Multicast mode. Event Reporting Shows the current status of the Event Reporting mode. Nightringer Shows the current status of the Nightringer mode. Primary SIP Server Shows the current status of the Primary SIP Server. Backup Server 1 Shows the current status of Backup Server 1. Backup Server 2 Shows the current status of Backup Server 2. Nightringer Server Shows the current status of Nightringer Server. Singlewire Settings Boot Time Shows the boot time. Current Time Shows the current time. IC Servers Shows the InformaCast server IP addresses. Configuration File Shows the configuration file. B’casts Accepted Shows the number of B’casts accepted. B’casts Rejected Shows the number of B’casts rejected. B’casts Active Shows the number of active B’casts. Import Settings Use this button to select a configuration file to import. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 31 Log in to the Configuration Home Page Table 2-9. Home Page Overview (continued) Web Page Item Description After selecting a configuration file, click Import to import the configuration from the selected file. Then, click Save and Reboot to store changes. Export Settings Click Export to export the current configuration to a file. Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Reboot button to reboot the system. Click on the Toggle Help button to see a short description of some of the web page items. First click on the Toggle Help button, and you will see a question mark ( ) appear next to some of the web page items. Move the mouse pointer to hover over a question mark to see a short description of a specific web page item. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 32 Configure the Device 2.3.5 Configure the Device 1. Click the Device menu button to open the Device page. See Figure 2-24. Figure 2-24. Device Configuration Page Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 33 Configure the Device 2. On the Device page, you may enter values for the parameters indicated in Table 2-10. Note The question mark icon ( ) in the following table shows which web page items will be defined after the Toggle Help button is pressed. Table 2-10. Device Configuration Parameters Web Page Item Description Volume Settings (0-9) Disable Volume Control Dial Select this option to disable the volume control dial and enable digital volume control settings. SIP Volume Set the speaker volume for a SIP call. A value of 0 will mute the speaker during SIP calls. Multicast Volume Set the speaker volume for multicast audio streams. A value of 0 will mute the speaker during multicasts. Ring Volume Set the ring volume for incoming calls. A value of 0 will mute the speaker instead of playing the ring tone when Auto-Answer Incoming Calls is disabled. Sensor Volume Set the speaker volume for playing sensor activated audio. A value of 0 will mute the speaker during sensor activated audio. Volume Boost: Set the Boost level to increase the volume output of the speaker. Using Volume Boost may introduce audio clipping and/or distortion. Boost is only recommended for use with volumes set to level 9. No Volume Boost +4dB Clock Settings Set Time with NTP Server on boot When selected, the time is set with an external NTP server when the device restarts. NTP Server Use this field to set the address (in IPv4 dotted decimal notation or as a canonical name) for the NTP Server. This field can accept canonical names of up to 64 characters in length. Posix Timezone String See Section 2.3.5.1, "Time Zone Strings" for information about how to use the Posix Timezone String to specify time zone and daylight savings time where applicable. Enter up to 63 characters. Periodically sync time with server When selected, the time is periodically updated with the NTP server at the configured interval below. Time update period (in hours) The time interval after which the device will contact the NTP server to update the time. Enter up to 4 digits. Current Time Allows you to input the current time. (6 character limit) Power Settings 802.3AT Mode This device automatically detects if it is plugged into an 802.3AT (also known as PoE Plus) power source. 802.3AT provides more power than older 802.3AT power sources and allows this speaker to play audio at higher volumes. If you are sure this speaker is connected to an 802.3AT power source, but it is not being detected correctly, you can override the automatic settings below. Force 802.3AT Mode (NOT recommended) Enable this option if you are sure this speaker is connected to an 802.3AT power source, but it is not being detected correctly (not recommended). Auxiliary Power Supply This device can be connected to a +24VDC auxiliary power supply. Check this box if this is how this speaker is being powered. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 34 Configure the Device Table 2-10. Device Configuration Parameters (continued) Web Page Item Description Singlewire Broadcast Strobe Settings For up to 10 Singlewire pages, when a priority is specified for the page, a corresponding strobe scene will be activated. The color may be selected from the drop down menu, or customized by the user with the 0-255 scale. Brightness is specified with a value between 0 and 100. Priority Indicates the priority of the Singlewire broadcast, with 1 the highest priority and 10 the lowest. Scene Use this section to select the strobe flashing behavior for the Singlewire Broadcast. ADA Compliant Strobe will blink ON at the specified brightness for 150ms then OFF for 350ms during the duration of the event. Slow Fade Strobe will increase in brightness from 0 to the specified brightness and back to 0 over the course of about 3.5 seconds during the duration of the event. Fast Fade Strobe will increase in brightness from 0 to the specified brightness and back to 0 over the course of about 1.5 seconds during the duration of the event. Slow Blink Strobe will blink ON at the specified brightness for one second then OFF for one second during the duration of the event. Fast Blink Strobe will blink ON at the specified brightness then OFF five times per second during the duration of the event. Color Select the desired color (only one may be chosen). Brightness How bright the strobe will blink when there is a Singlewire Broadcast. This is the maximum brightness for “fade” type scenes. Red The red LED value for the Singlewire Broadcast. Green The green LED value for the Singlewire Broadcast. Blue The blue LED value for the Singlewire Broadcast. Use this button to preview the strobe flashing behavior for the Singlewire Broadcast Strobe Settings. Line-In Settings Enable Line-in to Line-out Loopback Line-in audio will play back out the device's audio output ports. This is the lowest priority audio and will be preempted by any other audio stream. DTMF Settings Require Security Code When selected, the user will be prompted to enter a Security Code (entered on this page) before being able to execute a page when calling the device. Security Code Type the Security Code in this field. The Security Code must only use characters '0-9', '*' and '#'. Enter up to 25 characters. Relay Settings Activate Relay with DTMF Code Operations Guide Activates the relay when the DTMF Activation Code is entered on the phone during a SIP call with the device. RFC2833 DTMF payload types are supported. 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 35 Configure the Device Table 2-10. Device Configuration Parameters (continued) Web Page Item Description Relay Pulse Code DTMF code used to pulse the relay when entered on a phone during a SIP call with the device. Relay will activate for Relay Pulse Duration seconds then deactivate. Activate Relay with DTMF Code must be enabled. Enter up to 25 digits (* and # are supported). Relay Pulse Duration (in seconds) The length of time (in seconds) during which the relay will be activated when the DTMF Relay Activation Code is detected. Enter up to 5 digits. Relay Activation Code Activation code used to activate the relay when entered on a phone during a SIP call with the device. Relay will be active indefinitely, or until the DTMF Relay Deactivation code is entered. Activate Relay with DTMF Code must be enabled. Enter up to 25 digits (* and # are supported). Relay Deactivation Code Code used to deactivate the relay when entered on a phone during a SIP call with the device. Activate Relay with DTMF Code must be enabled. Enter up to 25 digits (* and # are supported). Activate Relay During Ring When selected, the relay will be activated for as long as the device is ringing. When Auto-Answer Incoming Calls is enabled, the device will not ring and this option does nothing. Activate Relay During Night Ring When selected, the relay will be activated as long as the Nightringer extension is ringing. Activate Relay While Call Active When selected, the relay will be activated as long as the SIP call is active. Misc Settings Device Name Type the device name. Enter up to 25 characters. Auto-Answer Incoming Calls When selected, the device will automatically answer incoming calls. When Auto-Answer Incoming Calls is disabled, the device will play a ring tone (corresponds to Ring Tone on the Audiofiles page) out of the speaker. Beep on Init Device will play the user-defined “pagetone” audio file when it boots. Beep on Page Device will play the user defined “pagetone” audio file before playing a SIP page. Disable HTTPS (NOT recommended) Disables the encrypted connection to the webpage. We do not recommend disabling HTTPS for security reasons. Two Speakers Connected Specify if one or two speakers are connected to the paging amplifier. If only one is connected, ensure that it is wired to the first set of terminal blocks. RGB Strobe Status of optional RGB Strobe. Click on the Test Audio button to do an audio test. When the Test Audio button is pressed, you will hear a voice message for testing the device audio quality and volume. Click on the Test Relay button to do a relay test. Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 36 Configure the Device Table 2-10. Device Configuration Parameters (continued) Web Page Item Description Click on the Reboot button to reboot the system. Click on the Toggle Help button to see a short description of some of the web page items. First click on the Toggle Help button, and you will see a question mark ( ) appear next to some of the web page items. Move the mouse pointer to hover over a question mark to see a short description of a specific web page item. Note Operations Guide You can change the SIP Volume, Multicast Volume, Ring Volume, and Sensor Volume without rebooting the device. You must save and reboot the device for other changes to take effect. 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 37 Configure the Device 2.3.5.1 Time Zone Strings The posix time zone string tells the internal date and time utilities how to handle daylight savings time for different time zones. Table 2-23 shows some common strings. Table 2-11. Common Time Zone Strings Time Zone Time Zone String US Pacific time PST8PDT,M3.2.0/2:00:00,M11.1.0/2:00:00 US Mountain time MST7MDT,M3.2.0/2:00:00,M11.1.0/2:00:00 US Eastern Time EST5EDT,M3.2.0/2:00:00,M11.1.0/2:00:00 a Phoenix Arizona MST7 US Central Time CST6DST,M3.2.0/2:00:00,M11.1.0/2:00:00 a.Phoenix, Arizona does not use daylight savings time. Table 2-24 shows a breakdown of the parts that constitute the following time zone string: ● CST6DST,M3.2.0/2:00:00,M11.1.0/2:00:00 Table 2-12. Time Zone String Parts Operations Guide Time Zone String Part Meaning CST6CDT The time zone offset from GMT and three character identifiers for the time zone. CST Central Standard Time 6 The (hour) offset from GMT/UTC CDT Central Daylight Time M3.2.0/2:00:00 The date and time when daylight savings begins. M3 The third month (March) .2 The 2nd occurrence of the day (next item) in the month .0 Sunday /2:00:00 Time of day to change M11.1.0/2:00:00 The date and time when daylight savings ends. M11 The eleventh month (November) .1 The 1st occurrence of the day (next item) in the month .0 Sunday /2:00:00 Time of day to change 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 38 Configure the Device Time Zone String Examples Table 2-25 has some more examples of time zone strings. Table 2-13. Time Zone String Examples Time Zone Time Zone String a Tokyo IST-9 Berlinb CET-1MET,M3.5.0/1:00,M10.5.0/1:00 a.Tokyo does not use daylight savings time. b.For Berlin, daylight savings time starts on the last Sunday in March at 01:00 UTC, and ends on the last Sunday in October at 01:00 UTC, and is one hour ahead of UTC. Time Zone Identifier A user-definable three or four character time zone identifier (such as PST, EDT, IST, MUT, etc) is needed at the beginning of the posix time zone string to properly set the time. However, the specific letters or numbers used for the time zone identifier are not important and can be any three or four letter or number combination that is chosen by the user. However, the time zone identifier cannot be blank. Figure 2-25. Three or Four Character Time Zone Identifier You can also use the following URL when a certain time zone applies daylight savings time: http://www.timeanddate.com/time/dst/2011.html World GMT Table Table 2-26 has information about the GMT time in various time zones. Table 2-14. World GMT Table Operations Guide Time Zone City or Area Zone Crosses GMT-12 Eniwetok GMT-11 Samoa GMT-10 Hawaii GMT-9 Alaska GMT-8 PST, Pacific US GMT-7 MST, Mountain US GMT-6 CST, Central US GMT-5 EST, Eastern US GMT-4 Atlantic, Canada GMT-3 Brazilia, Buenos Aries GMT-2 Mid-Atlantic GMT-1 Cape Verdes GMT Greenwich Mean Time, Dublin GMT+1 Berlin, Rome GMT+2 Israel, Cairo GMT+3 Moscow, Kuwait GMT+4 Abu Dhabi, Muscat 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 39 Configure the Device Table 2-14. World GMT Table (continued) Operations Guide Time Zone City or Area Zone Crosses GMT+5 Islamabad, Karachi GMT+6 Almaty, Dhaka GMT+7 Bangkok, Jakarta GMT+8 Hong Kong, Beijing GMT+9 Tokyo, Osaka GMT+10 Sydney, Melbourne, Guam GMT+11 Magadan, Soloman Is. GMT+12 Fiji, Wellington, Auckland 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 40 Configure the Network Parameters 2.3.6 Configure the Network Parameters 1. Click the Network menu button to open the Network page (Figure 2-26). Figure 2-26. Network Configuration Page Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 41 Configure the Network Parameters 2. On the Network page, enter values for the parameters indicated in Table 2-15. Note The question mark icon ( ) in the following table shows which web page items will be defined after the Toggle Help button is pressed. Table 2-15. Network Configuration Parameters Web Page Item Description Stored Network Settings Addressing Mode Select either DHCP IP Addressing or Static Addressing by marking the appropriate radio button. DHCP Addressing mode is enabled on default and the device will attempt to resolve network addressing with the local DHCP server upon boot. If DHCP Addressing fails, the device will revert to the last known IP address or the factory default address if no prior DHCP lease was established. See Section 2.3.1, "Factory Default Settings" for factory default settings. Be sure to click Save and Reboot to store changes when configuring a Static address. Hostname This is the hostname provided by the DHCP server. See the DHCP/DNS server documentation for more information. Enter up to 64 characters. IP Address Enter the Static IPv4 network address in dotted decimal notation. Subnet Mask Enter the Subnet Mask in dotted decimal notation. Default Gateway Enter the Default Gateway IPv4 address in dotted decimal notation. DNS Server 1 Enter the primary DNS Server IPv4 address in dotted decimal notation. DNS Server 2 Enter the secondary DNS Server IPv4 address in dotted decimal notation. DHCP Timeout in seconds Specify the desired time-out duration (in seconds) that the device will wait for a response from the DHCP server before reverting back to the stored static IP address. The stored static IP address may be the last known IP address or the factory default address if no prior DHCP lease was established. Enter up to 8 characters. A value of -1 will retry forever. Current Network Settings Shows the current network settings. IP Address Shows the current Static IP address. Subnet Mask Shows the current Subnet Mask address. Default Gateway Shows the current Default Gateway address. DNS Server 1 Shows the current DNS Server 1 address. DNS Server 2 Shows the current DNS Server 2 address. VLAN Settings VLAN ID (0-4095) Specify the IEEE 802.1Q VLAN ID number. Enter up to 4 digits. Note: The device supports 802.1Q VLAN tagging support. The switch port connected to the device will need to be in “trunking mode” for the VLAN tags to propagate. VLAN Priority (0-7) Operations Guide Specify the IEEE 802.1p VLAN priority level. Enter 1 digit. A value of 0 may cause the VLAN ID tag to be ignored. 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 42 Configure the Network Parameters Table 2-15. Network Configuration Parameters (continued) Web Page Item Description Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Reboot button to reboot the system. Click on the Toggle Help button to see a short description of some of the web page items. First click on the Toggle Help button, and you will see a question mark ( ) appear next to some of the web page items. Move the mouse pointer to hover over a question mark to see a short description of a specific web page item. Note Operations Guide You must click on the Save button and then the Reboot button for the changes to take effect. 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 43 Configure the SIP (Session Initiation Protocol) Parameters 2.3.7 Configure the SIP (Session Initiation Protocol) Parameters 1. Click on the SIP menu button to open the SIP page (Figure 2-27). Figure 2-27. SIP Configuration Page Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 44 Configure the SIP (Session Initiation Protocol) Parameters Figure 2-28. SIP Configuration Page Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 45 Configure the SIP (Session Initiation Protocol) Parameters 2. On the SIP page, enter values for the parameters indicated in Table 2-16. Note The question mark icon ( ) in the following table shows which web page items will be defined after the Toggle Help button is pressed. Table 2-16. SIP Configuration Parameters Web Page Item Description SIP Settings Enable SIP Operation When enabled, the device will transmit, receive, and process SIP messages according to the configured SIP settings below. Register with a SIP Server When enabled, the device will attempt to register to the configured SIP Server(s) on this page. To configure the device to send and receive pointto-point SIP calls, enable SIP Operation and disable Register with a SIP Server (see Section 2.3.7.2, "Point-to-Point Configuration"). Use Cisco SRST When enabled, the backup servers are handled according to Cisco SRST (Survivable Remote Site Telephony). It is required for use in clustered Cisco Unified Communications Manager topologies. Primary SIP Server Enter the SIP server address as an IPv4 address in dotted decimal notation or a fully qualified domain name. This parameter also becomes the host portion of the SIP-URI for the device's extension on the primary SIP server. This field can accept entries of up to 255 characters in length. Primary SIP User ID Specify the SIP User ID for the Primary SIP Server. This parameter becomes the user portion of the SIP-URI for the device's extension on the primary SIP server. Enter up to 64 alphanumeric characters. Primary SIP Auth ID Specify the Authenticate ID for the Primary SIP Server. This parameter is required for SIP registration authentication. Enter up to 64 alphanumeric characters. Primary SIP Auth Password Specify the Authenticate Password for the Primary SIP Server. This parameter is required for SIP registration authentication. Enter up to 64 alphanumeric characters. Backup SIP Server 1 Enter the backup SIP server address as an IPv4 address in dotted decimal notation or a fully qualified domain name. This parameter also becomes the host portion of the SIP-URI for the device's extension on the backup SIP server. This field can accept entries of up to 255 characters in length. Backup SIP User ID 1 Specify the SIP User ID for the first backup SIP Server. This parameter becomes the user portion of the SIP-URI for the device's extension on the first backup SIP server. Enter up to 64 alphanumeric characters. Backup SIP Auth ID 1 Specify the Authenticate ID for the first backup SIP server. This parameter is required for SIP registration authentication. Enter up to 64 alphanumeric characters. Backup SIP Auth Password 1 Specify the Authenticate Password for the first backup SIP server. This parameter is required for SIP registration authentication. Enter up to 64 alphanumeric characters. Backup SIP Server 2 Enter a second backup SIP server address as an IPv4 address in dotted decimal notation or a fully qualified domain name. This parameter also becomes the host portion of the SIP-URI for the device's extension on the second backup SIP server. This field can accept entries of up to 255 characters in length. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 46 Configure the SIP (Session Initiation Protocol) Parameters Table 2-16. SIP Configuration Parameters (continued) Web Page Item Description Backup SIP User ID 2 Specify the SIP User ID for the second backup SIP Server. This parameter becomes the user portion of the SIP-URI for the device's extension on the second backup SIP server. Enter up to 64 alphanumeric characters. Backup SIP Auth ID 2 Specify the Authenticate ID for the second backup SIP server. This parameter is required for SIP registration authentication. Enter up to 64 alphanumeric characters. Backup SIP Auth Password 2 Specify the Authenticate Password for the second backup SIP server. This parameter is required for SIP registration authentication. Enter up to 64 alphanumeric characters. Remote SIP Port The Remote SIP Port is the port number the device will use as the destination port when sending SIP messages. The default Remote SIP Port is 5060. The supported range is 0-65536. Enter up to 5 digits. Local SIP Port The Local SIP Port is the port number the device will use to receive SIP messages. The default Local SIP Port is 5060. The supported range is 065536. Enter up to 5 digits. Outbound Proxy Enter the Outbound Proxy address as an IPv4 address in dotted decimal notation or a fully qualified domain name (FQDN). When an IP address is configured, the device will send all SIP messages to this IP address. When an FQDN is configured, the device will run DNS NAPTR, SRV, and A queries on the FQDN to resolve an IP address to which it will send all SIP messages. This field can accept entries of up to 255 characters in length. Outbound Proxy Port The Outbound Proxy Port is port number used as the destination port when sending SIP messages to the outbound proxy. A value of 0 will default to 5060. The supported range is 0-65536. Enter up to 5 digits. Disable rport Discovery Disabling rport Discovery will prevent the device from including the public WAN IP address and port number in the contact information that is sent to the remote SIP servers. This will generally only need to be enabled when using an SBC or SIP ALG in conjunction with a remote SIP server. Buffer SIP Calls Also referred to as delayed paging. Device will buffer up to 4 minutes of audio then play back the recording after hang up. Re-registration Interval (in seconds) The SIP Re-registration interval (in seconds) is the SIP Registration lease time, also known as the expiry. The supported range is 30-3600 seconds. Enter up to 4 digits. Unregister on Boot When enabled, the device will send one registration with an expiry of 0 on boot. Keep Alive Period The minimum time in milliseconds between keep-alive packets sent for nat traversal. A value of 0 will disable keep alive packets. SIP Strobe Settings Blink Strobe on Ring When selected, the Strobe will blink a scene when ringing. SIP Call Strobe Brightness How bright the strobe will blink when there is a SIP Call. This is the maximum brightness for “fade” type scenes. ADA Compliant Strobe will blink ON at the specified brightness for 150ms then OFF for 350ms during the duration of the event. Slow Fade Strobe will increase in brightness from 0 to the specified brightness and back to 0 over the course of about 3.5 seconds during the duration of the event. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 47 Configure the SIP (Session Initiation Protocol) Parameters Table 2-16. SIP Configuration Parameters (continued) Web Page Item Description Fast Fade Strobe will increase in brightness from 0 to the specified brightness and back to 0 over the course of about 1.5 seconds during the duration of the event. Slow Blink Strobe will blink ON at the specified brightness for one second then OFF for one second during the duration of the event. Fast Blink Strobe will blink ON at the specified brightness then OFF five times per second during the duration of the event. SIP Call Color Select desired color (only one may be chosen). Red The red LED value for SIP Call. Green The green LED value for SIP Call. Blue The blue LED value for SIP Call. Use this button to preview the strobe flashing behavior for the MWI Strobe Settings. MWI Strobe Settings Blink Strobe on MWI When selected, the strobe will blink a scene when a voicemail is waiting for its extension. MWI Strobe Brightness How bright the strobe will blink when there is a message waiting. This is the maximum brightness for “fade” type scenes. ADA Compliant Strobe will blink ON at the specified brightness for 150ms then OFF for 350ms during the duration of the event. Slow Fade Strobe will increase in brightness from 0 to the specified brightness and back to 0 over the course of about 3.5 seconds during the duration of the event. Fast Fade Strobe will increase in brightness from 0 to the specified brightness and back to 0 over the course of about 1.5 seconds during the duration of the event. Slow Blink Strobe will blink ON at the specified brightness for one second then OFF for one second during the duration of the event. Fast Blink Strobe will blink ON at the specified brightness then OFF five times per second during the duration of the event. MWI Call Color Select desired color (only one may be chosen). Red The red LED value for MWI. Green The green LED value for MWI. Blue The blue LED value for MWI. Use this button to preview the strobe flashing behavior for the MWI Strobe Settings. Nightringer Settings Enable Nightringer Operations Guide When Nightringer is enabled, the device will attempt to register a second extension with the SIP server. Any calls made to this extension will play a ringtone (corresponds to Night Ring on the Audiofiles page). By design, it is not possible to answer a call to the Nightringer extension. 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 48 Configure the SIP (Session Initiation Protocol) Parameters Table 2-16. SIP Configuration Parameters (continued) Web Page Item Description SIP Server Enter the SIP server address as an IPv4 address in dotted decimal notation or a fully qualified domain name. This parameter also becomes the host portion of the SIP-URI for the device's Nightringer extension on the SIP server. This field can accept entries of up to 255 characters in length. Remote SIP Port The Remote SIP Port is the port number the device will use as the destination port when sending SIP messages for the Nightringer extension. The default Remote SIP Port is 5060. The supported range is 0-65536. Enter up to 5 digits. Local SIP Port The Local SIP Port is the port number the device will use to receive SIP messages for the Nightringer extension. This value cannot be the same as the Local SIP Port for the primary extension. The default Local SIP Port is 5061. The supported range is 0-65536. Enter up to 5 digits. Outbound Proxy Enter the Outbound Proxy address as an IPv4 address in dotted decimal notation or a fully qualified domain name (FQDN). When an IP address is configured, the device will send all SIP messages to this IP address for the Nightringer extension. When an FQDN is configured, the device will run DNS NAPTR, SRV, and A queries on the FQDN to resolve an IP address to which it will send all SIP messages for the Nightringer extension. This field can accept entries of up to 255 characters in length. Outbound Proxy Port The Outbound Proxy Port is port number used as the destination port when sending SIP messages to the outbound proxy for the Nightringer extension. A value of 0 will default to 5060. The supported range is 065536. Enter up to 5 digits. User ID Specify the SIP User ID for the SIP server. This parameter becomes the user portion of the SIP-URI for the device's Nightringer extension. Enter up to 64 alphanumeric characters. Authenticate ID Specify the Authenticate ID for the SIP Server. This parameter is required for SIP registration authentication. Enter up to 64 alphanumeric characters. Authenticate Password Specify the Authenticate Password for the SIP Server. This parameter is required for SIP registration authentication. Enter up to 64 alphanumeric characters. Re-registration Interval (in seconds) The SIP Re-registration Interval (in seconds) is the SIP Registration lease time, also known as the expiry. The supported range is 30-3600 seconds. Enter up to 4 digits. Nightringer Strobe Settings Blink Strobe on Nightring When selected, the Strobe will blink a scene when the Nightinger is ringing. Nightringer Strobe Brightness How bright the strobe will blink when the Nightringer is ringing. This is the maximum brightness for “fade” type scenes. ADA Compliant Strobe will blink ON at the specified brightness for 150ms then OFF for 350ms during the duration of the event. Slow Fade Strobe will increase in brightness from 0 to the specified brightness and back to 0 over the course of about 3.5 seconds during the duration of the event. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 49 Configure the SIP (Session Initiation Protocol) Parameters Table 2-16. SIP Configuration Parameters (continued) Web Page Item Description Fast Fade Strobe will increase in brightness from 0 to the specified brightness and back to 0 over the course of about 1.5 seconds during the duration of the event. Slow Blink Strobe will blink ON at the specified brightness for one second then OFF for one second during the duration of the event. Fast Blink Strobe will blink ON at the specified brightness then OFF five times per second during the duration of the event. Nightringer Call Color Select desired color (only one may be chosen). Red The red LED value for Nightringer. Green The green LED value for Nightringer. Blue The blue LED value for Nightringer. Use this button to preview the strobe flashing behavior for the Nightringer Strobe Settings. RTP Settings RTP Port (even) Specify the port number used for the RTP stream after establishing a SIP call. This port number must be an even number and defaults to 10500. The supported range is 0-65536. Enter up to 5 digits. Jitter Buffer Specify the size of the jitter buffer (in milliseconds) used for SIP calls. Valid values are 50-1000. Call Disconnection Terminate Call After Delay Automatically terminate an active call after a given delay in seconds. A value of 0 will disable this function. Enter up to 8 digits. Codec Selection Force Selected Codec When configured, this option will allow you to force the device to negotiate for the selected codec. Otherwise, the device will perform codec negotiation using the default list of supported codecs. Codec Select the desired codec (only one may be chosen). Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Reboot button to reboot the system. Click on the Toggle Help button to see a short description of some of the web page items. First click on the Toggle Help button, and you will see a question mark ( ) appear next to some of the web page items. Move the mouse pointer to hover over a question mark to see a short description of a specific web page item. Note You must click on the Save button and then the Reboot button for the changes to take effect. Note For specific server configurations, go to the following website address: http://www.cyberdata.net/connecting-to-ip-pbx-servers/ Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 50 Configure the SIP (Session Initiation Protocol) Parameters 2.3.7.1 Dial Out Extension Strings and DTMF Tones (using rfc2833) On the SIP Configuration Page, dial out extensions support the addition of comma delimited pauses and sending additional DTMF tones (using rfc2833). The first comma will pause three seconds after a call is first established with a remote device. Subsequent commas will pause for 2 seconds. A pause of one second will be sent after each numerical digit. Table 2-17. Examples of Dial-Out Extension Strings Extension String Resulting Action 302 Dial out extension 302 and establish a call 302,2 Dial out extension 302 and establish a call, wait 3 seconds then send the DTMF tone '2' 302,25,,,4,,1 Dial out extension 302 and establish a call, wait 3 seconds then send the DTMF tone '2', send out DTMF tone 5, wait 6 seconds, send out DTMF tone 4, wait 4 seconds, send out DTMF tone 1 Note Operations Guide The maximum number of total characters in the dial-out field is 64. 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 51 Configure the SIP (Session Initiation Protocol) Parameters 2.3.7.2 Point-to-Point Configuration When the device is set to not register with a SIP server (see Figure 2-29), it is possible to set the device to dial out to a single endpoint. In this case, the dial-out extension should be the IP address of the remote device. The device can also receive Point-to-Point calls. The delayed DTMF functionality is available in the Point-to-Point Mode. Note Receiving point-to-point SiP calls may not work with all phones. Figure 2-29. SIP Page Set to Point-to-Point Mode Device is set to NOT register with a SiP server Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 52 Configure the SIP (Session Initiation Protocol) Parameters 2.3.7.3 Delayed DTMF On the SIP Configuration page the dial out extension supports the addition of comma delimited pauses and sending additional DTMF tones (using rfc2833). The first comma will pause three seconds after a call is first established with a remote device. Subsequent commas will pause for 2 seconds. A pause of one second will be sent after each numerical digit. Table 2-18. Examples of Dial-Out Extension Strings Extension String Resulting Action 302 Dial out extension 302 and establish a call 302,2 Dial out extension 302 and establish a call, wait 3 seconds then send the DTMF tone '2' 302,25,,,4,,1 Dial out extension 302 and establish a call, wait 3 seconds then send the DTMF tone '2', send out DTMF tone 5, wait 6 seconds, send out DTMF tone 4, wait 4 seconds, send out DTMF tone 1 Note Operations Guide The maximum number of total characters in the dial-out field is 25. 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 53 Configure the Multicast Parameters 2.3.8 Configure the Multicast Parameters The Multicast Configuration page allows the device to join up to ten paging zones for receiving ulaw/alaw encoded RTP audio streams. A paging zone can consist of one or many CyberData multicast group-enabled products. There is no limit to how many speakers can be in a given paging zone. Each multicast group is defined by a multicast address and port number. Each multicast group is assigned a priority, allowing simultaneously arriving pages to be serviced based on importance. Multicast groups are compatible with IGMP through version 3. The device supports simultaneous SIP and Multicast. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 54 Configure the Multicast Parameters 1. Click on the Multicast menu button to open the Multicast page. See Figure 2-30. Figure 2-30. Multicast Configuration Page Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 55 Configure the Multicast Parameters 2. On the Multicast page, enter values for the parameters indicated in Table 2-19. Note The question mark icon ( ) in the following table shows which web page items will be defined after the Toggle Help button is pressed. Table 2-19. Multicast Configuration Parameters Web Page Item Description Enable Multicast Operation Enables or disables multicast operation. Priority Indicates the priority for the multicast group. Priority 9 is the highest (emergency streams). 0 is the lowest (background music). SIP calls are considered priority 4.5. See Section 2.3.8.1, "Assigning Priority" for more details. Address Enter the multicast IP Address for this multicast group (15 character limit). Port Enter the port number for this multicast group (5 character limit [range can be from 2000 to 65535]). Note: The multicast ports have to be even values. The webpage will enforce this restriction. Name Assign a descriptive name for this multicast group (25 character limit). Buffer Device will buffer up to four minutes of audio and then play back the recording after the multicast stream finishes or after the buffer is full. Beep When selected, the device will play a beep before multicast audio is sent. Relay When selected, the device will activate a relay before multicast audio is sent. Polycom Default Channel When a default Polycom channel/group number is selected, the device will subscribe to the default channel for one-way group pages. Group Numbers 1-25 are supported. Or, select Disabled to disable this channel. Polycom Priority Channel When a priority Polycom channel/group number is selected, the device will subscribe to the priority channel for one-way group pages. Group Numbers 1-25 are supported. Or, select Disabled to disable this channel. Polycom Emergency Channel When an emergency Polycom channel/group number is selected, the device will subscribe to the default channel for one-way group pages. Group Numbers 1-25 are supported. Or, select Disabled to disable this channel. Multicast Strobe Settings Blink Strobe on Multicast When selected, the Strobe will blink a scene when a multicast is received. Multicast Strobe Brightness How bright the strobe will blink on a multicast page. This is the maximum brightness for “fade” type scenes. ADA Compliant Strobe will blink ON at the specified brightness for 150ms then OFF for 350ms during the duration of the event. Slow Fade Strobe will increase in brightness from 0 to the specified brightness and back to 0 over the course of about 3.5 seconds during the duration of the event. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 56 Configure the Multicast Parameters Table 2-19. Multicast Configuration Parameters (continued) Web Page Item Description Fast Fade Strobe will increase in brightness from 0 to the specified brightness and back to 0 over the course of about 1.5 seconds during the duration of the event. Slow Blink Strobe will blink ON at the specified brightness for one second then OFF for one second during the duration of the event. Fast Blink Strobe will blink ON at the specified brightness then OFF five times per second during the duration of the event. Multicast Call Color Select desired color (only one may be chosen). Red The red LED value for Multicast. Green The green LED value for Multicast. Blue The blue LED value for Multicast. Use this button to preview the strobe flashing behavior for the Multicast Strobe Settings. Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Reboot button to reboot the system. Click on the Toggle Help button to see a short description of some of the web page items. First click on the Toggle Help button, and you will see a question mark ( ) appear next to some of the web page items. Move the mouse pointer to hover over a question mark to see a short description of a specific web page item. Note You must click on the Save button and then the Reboot button for the changes to take effect. 2.3.8.1 Assigning Priority The device will prioritize simultaneous audio streams according to their priority in the list. If both SIP and Multicast is enabled, SIP audio streams are considered priority 4.5. SIP audio will interrupt multicast streams with priority 0 through 4 and will be interrupted by multicast streams with priority 5 through 9. During priority 9 multicast streams, the volume is set to maximum. Note Ringtones and Nightringtones Operations Guide SIP calls, multicast streams, ring tones, ringback tones, and nightring tones are all prioritized. Ringtones all play at the same priority level. This means that it is possible to have a nightring tone and a normal ringtone playing at the same time. 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 57 Configure the Sensor Configuration Parameters 2.3.9 Configure the Sensor Configuration Parameters The door sensor (pins 1 and 2) on the terminal block can be used to monitor a door's open or closed state. There is an option on the Sensor Configuration Page to trigger on an open or short condition on these pins. The door sensor alarm will be activated when the Sensor Timeout (in seconds) parameter has been met. Each sensor can trigger up to five different actions: • Flash the LED until the sensor is deactivated (roughly 10 times/second) • Activate the relay until the sensor is deactivated • Loop an audio file out of the speaker until the sensor is deactivated • Call an extension and establish two way audio • Call an extension and play a pre-recorded audio file Note Calling a preset extension can be set up as a point-to-point call, but currently can't send delayed DTMF tones. 1. Click Sensor menu button to open the Sensor Configuration Page (Figure 2-31). Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 58 Configure the Sensor Configuration Parameters Figure 2-31. Sensor Configuration Page Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 59 Configure the Sensor Configuration Parameters 2. On the Sensor page, enter values for the parameters indicated in Table 2-20. Note The question mark icon ( ) in the following table shows which web page items will be defined after the Toggle Help button is pressed. Table 2-20. Sensor Configuration Parameters Web Page Item Description Sensor Settings Sensor Normally Closed Select the inactive state of the sensor. The sensor is also known as the Sense Input on the device's terminal block. Sensor Timeout (in seconds) The time (in seconds) the device will wait before it performs an action when the on-board door sensor is activated. The action(s) performed are based on the configured Sensor Settings below. Enter up to 5 digits. Activate Relay When selected, the device's on-board relay will be activated until the on-board sensor is deactivated. Play Audio Locally When selected, the device will loop an audio file out of the speaker until the sensor is deactivated. Make call to extension When selected, the device will call an extension when the onboard door sensor is activated. Use the Dial Out Extension field below to specify the extension the device will call. Dial Out Extension Specify the extension the device will call when the on-board sensor is activated. Enter up to 64 alphanumeric characters. Dial Out ID An additional Caller identification string added to outbound calls. Enter up to 64 alphanumeric characters. Play recorded audio When selected, the device will call the Dial Out Extension and play an audio file to the phone answering the SIP call (corresponds to Sensor Triggered on the Audiofiles Page page). Repeat Sensor Message The number of times to repeat the audio message through the local speaker or to the remote endpoint. A value of 0 will repeat the message while the sensor is active. Enter a value from 065536. Click the Test Sensor button to test the sensor. Sensor Strobe Settings Operations Guide Blink Strobe on Sensor When selected, the Strobe will blink a scene when the sensor is triggered. Sensor Strobe Brightness How bright the strobe will blink when the sensor is triggered. This is the maximum brightness for “fade” type scenes. ADA Compliant Strobe will blink ON at the specified brightness for 150ms then OFF for 350ms during the duration of the event. Slow Fade Strobe will increase in brightness from 0 to the specified brightness and back to 0 over the course of about 3.5 seconds during the duration of the event. 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 60 Configure the Sensor Configuration Parameters Table 2-20. Sensor Configuration Parameters (continued) Web Page Item Description Fast Fade Strobe will increase in brightness from 0 to the specified brightness and back to 0 over the course of about 1.5 seconds during the duration of the event. Slow Blink Strobe will blink ON at the specified brightness for one second then OFF for one second during the duration of the event. Fast Blink Strobe will blink ON at the specified brightness then OFF five times per second during the duration of the event. Sensor Color Select desired color (only one may be chosen). Red The red LED value for Sensor. Green The green LED value for Sensor. Blue The blue LED value for Sensor. Use this button to preview the strobe flashing behavior for the Sensor Strobe Settings. Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Reboot button to reboot the system. Click on the Toggle Help button to see a short description of some of the web page items. First click on the Toggle Help button, and you will see a question mark ( ) appear next to some of the web page items. Move the mouse pointer to hover over a question mark to see a short description of a specific web page item. Note Operations Guide You must click on the Save button for the changes to take effect. 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 61 Configure the Audio Configuration Parameters 2.3.10 Configure the Audio Configuration Parameters The Audiofiles page is used to add custom audio to the board. User uploaded audio will take precedence over the audio files shipped with the device. 1. Click on the Audiofiles menu button to open the Audiofiles page (Figure 2-32). Figure 2-32. Audiofiles Page Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 62 Configure the Audio Configuration Parameters Figure 2-33. Audiofiles Page 2. On the Audiofiles page, enter values for the parameters indicated in Table 2-21. Note The question mark icon ( ) in the following table shows which web page items will be defined after the Toggle Help button is pressed. Table 2-21. Audiofiles Configuration Parameters Web Page Item Description Available Space Shows the space available for the user to save custom audio files if they want to change the message when the door or sensor is triggered. 0-4 The name of the audio configuration option is the same as the spoken audio that plays on the board (24 character limit). '0' corresponds to the spoken word “zero.” '1' corresponds to the spoken word “one.” '2' corresponds to the spoken word “two.” '3' corresponds to the spoken word “three.” '4' corresponds to the spoken word “four.” Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 63 Configure the Audio Configuration Parameters Table 2-21. Audiofiles Configuration Parameters (continued) Web Page Item Description 5-9 The name of the audio configuration option is the same as the spoken audio that plays on the board (24 character limit). '5' corresponds to the spoken word “five.” '6' corresponds to the spoken word “six.” '7' corresponds to the spoken word “seven.” '8' corresponds to the spoken word “eight.” '9' corresponds to the spoken word “nine.” Dot Corresponds to the spoken word “dot.” (24 character limit) Audio Test Corresponds to the message “This is the CyberData IP speaker test message...” (24 character limit) Enter Code Corresponds to the message “Enter Code” (24 character limit). Invalid Code Corresponds to the message “Invalid Code” (24 character limit). Page Tone Corresponds to a simple tone used for beep on initialization and beep on page (24 character limit). Your IP Address is Corresponds to the message “Your IP address is...” (24 character limit). Rebooting Corresponds to the spoken word “Rebooting” (24 character limit). Restoring Default Corresponds to the message “Restoring default” (24 character limit). Ring Tone This is the tone that plays when set to ring when receiving a call (24 character limit). Sensor Triggered Corresponds to the message “Sensor Triggered” (24 character limit). Night Ring Specifies the ringtone for nightring. By default this parameter uses the same audio file that is selected for the Ring Tone parameter. Click on the Browse button to navigate to and select an audio file. The Play button will play that audio file. The Delete button will delete any user uploaded audio and restore the stock audio file. The Save button will download a new user audio file to the board once you've selected the file by using the Browse button. The Save button will delete any pre-existing user-uploaded audio files. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 64 Configure the Audio Configuration Parameters 2.3.10.1 User-created Audio Files User created audio files should be saved in the following format: RIFF (little-endian) data, WAVE audio, Microsoft PCM, 16 bit, mono 8000 Hz You can use the free utility Audacity to convert audio files into this format. See Figure 2-34 through Figure 2-36. Figure 2-34. Audacity 1 Figure 2-35. Audacity 2 Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 65 Configure the Audio Configuration Parameters When you export an audio file with Audacity, save the output as: • WAV (Microsoft) signed 16 bit PCM. Figure 2-36. WAV (Microsoft) signed 16 bit PCM WAV (Microsoft) signed 16 bit PCM Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 66 Configure the Events Parameters 2.3.11 Configure the Events Parameters The Events page specifies a remote server that can be used to receive HTTP POST events when actions take place on the board. 1. Click on the Events menu button to open the Events page (Figure 2-37). Figure 2-37. Event Configuration Page Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 67 Configure the Events Parameters 2. On the Events page, enter values for the parameters indicated in Table 2-22. Note The question mark icon ( ) in the following table shows which web page items will be defined after the Toggle Help button is pressed. Table 2-22. Events Configuration Parameters Web Page Item Description Enable Event Generation The device will send HTTP POST events to the specified remote server and port number whenever a certain action takes place. Select an event type below to generate an HTTP POST event. Events Enable Call Start Events When selected, the device will report the start of a SIP call. Enable Call Terminated Events When selected, the device will report the end of a SIP call. Enable Relay Activated Events When selected, the device will report relay activation. Enable Relay Deactivated Events When selected, the device will report relay deactivation. Enable Night Ring Events When selected, the device will report when it starts ringing upon an incoming SIP call to the Nightringer extension. As a reminder, the Nightringer extension always rings upon an incoming SIP call and it is not possible to alter this behavior. Enable Power On Events When selected, the device will report when it boots. Enable Multicast Start Events When selected, the device will report when the device starts playing a multicast audio stream. Enable Multicast Stop Events When selected, the device will report when the device stops playing a multicast audio stream. Enable Sensor Events When selected, the device will report when the on-board sensor is activated. Enable 60 Second Heartbeat Events When enabled, the device will report a Heartbeat event every 60 seconds. SIP registration is not required to generate Heartbeat events. Check All Click on Check All to select all of the events on the page. Uncheck All Click on Uncheck All to de-select all of the events on the page. Event Server Server IP Address The IPv4 address of the event server in dotted decimal notation. Server Port Specify the event server port number. The supported range is 065536. Enter up to 5 digits. Server URL Generally, the destination URL is the name of the application that receives the events and the string in the HTTP POST command. It can be a script used to parse and process the HTTP POST events. Enter up to 127 characters. Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Click on the Reboot button to reboot the system. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 68 Configure the Events Parameters Table 2-22. Events Configuration Parameters(continued) Web Page Item Description Click on the Toggle Help button to see a short description of some of the web page items. First click on the Toggle Help button, and you will see a question mark ( ) appear next to some of the web page items. Move the mouse pointer to hover over a question mark to see a short description of a specific web page item. Note Operations Guide You must click on the Save button and then the Reboot button for the changes to take effect. 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 69 Configure the Events Parameters 2.3.11.1 Example Packets for Events The server and port are used to point to the listening server and the 'Remote Event Server URL' is the destination URL (typically the script running on the remote server that's used to parse and process the POST events). Note The XML is URL-encoded before transmission so the following examples are not completely accurate. Here are example packets for every event: POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 User-Agent: CyberData/1.0.0 Content-Length: 197 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData Device' MAC='0020f70015b6'> <event>POWERON</event> </cyberdata> POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 User-Agent: CyberData/1.0.0 Content-Length: 199 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData Device' MAC='0020f70015b6'> <event>HEARTBEAT</event> </cyberdata> POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 User-Agent: CyberData/1.0.0 Content-Length: 196 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData Device' MAC='0020f70015b6'> <event>BUTTON</event> </cyberdata> POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 User-Agent: CyberData/1.0.0 Content-Length: 201 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData Device' MAC='0020f70015b6'> <event>CALL_ACTIVE</event> </cyberdata> POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 70 Configure the Events Parameters User-Agent: CyberData/1.0.0 Content-Length: 205 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData Device' MAC='0020f70015b6'> <event>CALL_TERMINATED</event> </cyberdata> POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 User-Agent: CyberData/1.0.0 Content-Length: 197 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData Device' MAC='0020f70015b6'> <event>RINGING</event> </cyberdata> POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 User-Agent: CyberData/1.0.0 Content-Length: 234 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData Device' MAC='0020f70015b6'> <event>MULTICAST_START</event> <index>8</index> </cyberdata> POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 User-Agent: CyberData/1.0.0 Content-Length: 233 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData Device' MAC='0020f70015b6'> <event>MULTICAST_STOP</event> <index>8</index> </cyberdata> POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 User-Agent: CyberData/1.0.0 Content-Length: 234 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData Device' MAC='0020f70015b6'> <event>RELAY_ACTIVATED</event> </cyberdata> POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 71 Configure the Events Parameters User-Agent: CyberData/1.0.0 Content-Length: 234 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData Device' MAC='0020f70015b6'> <event>RELAY_DEACTIVATED</event> </cyberdata> POST xmlparse_engine HTTP/1.1 Host: 10.0.3.79 User-Agent: CyberData/1.0.0 Content-Length: 234 Content-Type: application/x-www-form-urlencoded <?xml version="1.0" encoding="ISO-8859-1"?> <cyberdata NAME='CyberData Device' MAC='0020f70015b6'> <event>NIGHTRINGING</event> </cyberdata> Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 72 Configure the Autoprovisioning Parameters 2.3.12 Configure the Autoprovisioning Parameters Autoprovisioning can be used to automatically configure your device. The autoprovisioning file is an xml file with the device configuration. Values found in this file will override values stored in on-board memory. Note By default, the device will try to set up its configuration with autoprovisioning. 1. Click the Autoprov menu button to open the Autoprovisioning page. See Figure 2-38. Figure 2-38. Autoprovisioning Page Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 73 Configure the Autoprovisioning Parameters 2. On the Autoprovisioning page, you may enter values for the parameters indicated in Table 223. Note The question mark icon ( ) in the following table shows which web page items will be defined after the Toggle Help button is pressed. Table 2-23. Autoprovisioning Configuration Parameters Web Page Item Description Disable Autoprovisioning Prevent the device from automatically trying to download a configuration file. See Section 2.3.12.1, "Autoprovisioning" for more information. Autoprovisioning Server Enter the IPv4 address of the provisioning server in dotted decimal notation. Autoprovisioning Filename The autoprovisioning filename is the configuration filename. The default autoprovisioning filename is in the format of <mac address>.xml. Supported filename extensions are .txt, and .xml. The current filename is denoted by an asterisk at the bottom of the Autoprovisioning Page. Enter up to 256 characters. A file may have any name with an xml extension. If a file name is entered, the device will look for the specified file name, and only that file. Use tftp The device will use TFTP (instead of http) to download autoprovisioning files. Username The username used to authenticate with an autoprovisioning server. Leave this field blank to disable authentication. Password The password used to authenticate with an autoprovisioning server. Leave this field blank to disable authentication. Autoprovisioning Autoupdate (in minutes) The reoccurring time (in minutes) the device will wait before checking for new autoprovisioning files. Enter up to 6 digits. A value of 0 will disable this option. Note: To use the auto update options, enable the Set Time with NTP Server on boot setting on the Device Configuration Page page (see Table 2-10). Autoprovision at time (HHMMSS) The time of day the device will check for a new autoprovisioning file. The time must be 6 characters in length and in HHMMSS format. An empty value will disable this option. Note: To use the auto update options, enable the Set Time with NTP Server on boot setting on the Device Configuration Page page (see Table 2-10). The idle time (in minutes greater than 10) after which the device will check for a new autoprovisioning file. Enter up to 6 digits. A value of 0 will disable this option. Autoprovision when idle (in minutes > 10) Note: To use the auto update options, enable the Set Time with NTP Server on boot setting on the Device Configuration Page page (see Table 2-10). Click the Save button to save your configuration settings. Note: You need to reboot for changes to take effect. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 74 Configure the Autoprovisioning Parameters Table 2-23. Autoprovisioning Configuration Parameters (continued) Web Page Item Description Click on the Reboot button to reboot the system. Click on the Toggle Help button to see a short description of some of the web page items. First click on the Toggle Help button, and you will see a question mark ( ) appear next to some of the web page items. Move the mouse pointer to hover over a question mark to see a short description of a specific web page item. Press the Download Template button to create an autoprovisioning file for the device. See Section 2.3.12.3, "Download Template Button" Autoprovisioning log Note The autoprovisioning log provides information about the latest autoprovisioning attempt (i.e. dhcp options and server accessed and files parsed or not found). You must click on the Save button and then the Reboot button for the changes to take effect. 2.3.12.1 Autoprovisioning On boot, the device will look for an autoprovisioning server configured on the Autoprovisioning Page or specified as a DHCP option. When it finds a server, it will try to download the following (in order of preference): 1. The file configured on the autoprovisioning page. 2. A file named according to it's mac address (for example: 0020f7350058.xml). 3. The file 000000cd.xml The file can be hosted using a standard web server (like apache, IIS, or nginx), and the device can download over SSL. The file server can be an ipv4 address in dotted decimal notation or a fully qualified domain name. By default, the device will get its autoprovisioning server from the DHCP options. See Section 2.3.12.2, "Sample dhcpd.conf" for an example of how to configure dhcpd to offer autoprovisioning server addresses. If multiple options are set, the device will attempt to download autoprovisioning files from every server. The DHCP option determines the protocol used to download the autoprovisioning file. The device looks for DHCP options in the following order: 1. Option 43 - a FQDN or an IP address to an http server 2. Option 72 - an IP address to an http server 3. Option 150 - an IP address to a tftp server 4. Option 66 - an IP address to a tftp server or if the entry starts with 'http', a FQDN to a http server. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 75 Configure the Autoprovisioning Parameters You can download an autoprovisioning template file from the Autoprovisioning Page using the Download Template button (see Table 2-23). This file contains every configuration option that can be set on the board. Autoprovisioning files can contain the whole configuration or a subset of this file. The first autoprovisioning file can also contain links to other autoprovisioning files. The <MiscSettings> section contains some examples of additional autoprovisioning files: <MiscSettings> <DeviceName>CyberData Device</DeviceName> <!-<AutoprovFile>common.xml</AutoprovFile>--> <!-<AutoprovFile>sip_reg[macaddress].xml</AutoprovFile>--> <!-<AutoprovFile>audio[macaddress]</AutoprovFile>--> <!-<AutoprovFile>device[macaddress].xml</AutoprovFile>--> </MiscSettings> After downloading the first autoprovisioning file, the device will step through up to twenty additional <AutoprovFile> entries and try to download these files from the same server. When the device finds a filename with the string [macaddress], it will replace this string with the mac address. As an example, the user has configured option 43 on their DHCP server to “http://example.com,” and on their server, they have a file named 0020f7123456.xml (the same as the mac address of the device). Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 76 Configure the Autoprovisioning Parameters The file 0020f7123456.xml contains: <?xml version="1.0" encoding="utf-8" ?> <specific> <MiscSettings> <DeviceName>Newname</DeviceName> <AutoprovFile>common.xml</AutoprovFile> <AutoprovFile>sip_reg[macaddress].xml</AutoprovFile> <AutoprovFile>audio[macaddress]</AutoprovFile> <AutoprovFile>device.xml</AutoprovFile> </MiscSettings> </specific> 1. The device will first set it's name to 'Newname'. 2. It will try to download http://example.com/common.xml. 3. It will try to download http://example.com/sip_reg0020f7123456.xml. 4. It will try to download http://example.com/audio0020f7123456. 5. It will try to download http://example.com/device.xml. The device is reconfigured every time it downloads a new file so if two files configure the same option the last one will be the one that is saved. It is possible to autoprovision autoprovisioning values (for example, to disable autoprovisioning or to configure a time to check for new files). Checking for New The device will always check for an autoprovisioning files on boot but it can be configured to also Autoprovisioning check after a periodic delay, when idle, or at a specified time. When one of these options is set, the Files after Boot device will download its autoprovisioning files again, and if it finds any differences from the files it downloaded on boot, it will force a reboot and reconfigure. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 77 Configure the Autoprovisioning Parameters The Autoprovisioning Filename The autoprovisioning filename can contain a file, a file path, or a directory. Table 2-24. Autoprovisioning File Name Autoprovisioning Filename Autoprovisioning Server File Downloaded config.xml 10.0.1.3 10.0.1.3/config.xml /path/to/config.xml 10.0.1.3 10.0.1.3/path/to/config.xml subdirectory/path/ 10.0.1.3 10.0.1.3/subdirectory/path/0020f7020002.xml TFTP options may not support subdirectories. If a directory is set in the filename field, firmware and audio files will also be downloaded from this subdirectory. If the filename ends with a forward slash “/,” the device will treat it as a subdirectory. For example: The autoprovisioning server is set to “https://www.example.com” The autoprovisioning filename is set to “cyberdata/” On boot, the device will try to download: https://www.example.com/cyberdata/0020f7123456.xml ...and if this fails: https://www.example.com/cyberdata/000000cd.xml Audio files and firmware files will also add “cyberdata” to the URL before downloading. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 78 Configure the Autoprovisioning Parameters Autoprovisioning <FirmwareSettings> Firmware Updates <FirmwareFile>505-uImage-ceilingspeaker</FirmwareFile> <FirmwareServer>10.0.1.3</FirmwareServer> <OutdoorIntercom30>firmware_file_v9.3.0</OutdoorIntercom30> <OutdoorIntercom31>firmware_file_v10.3.0</OutdoorIntercom31> <CallButton31>firmware_file_v10.3.0</CallButton31> </FirmwareSettings> In the <FirmwareSettings> section, the <FirmwareServer> element can be used to specify a different server for hosting firmware files. When this element is not available, the device will try to download the file from the autoprovisioning server. The device will use the filename to determine when to autoprovision firmware updates. The default configuration is blank, so the first time you set a value in your autoprovisioning file, it may force a firmware update even if the firmware version has not changed. The <FirmwareFile> name can contain path elements (i.e. /path/to/firmware/10.3.0-uImage[device_file_name]). The device also supports product strings for downloading firmware. If the <FirmwareFile> option is not set, the device will look for its particular product string for a firmware filename. In this way, a generic autoprovisioning file can specify unique firmware for a range of products. The list of valid product strings: <ProductString>CallButton31</ProductString> <ProductString>EmergencyIntercom31</ProductString> <ProductString>EmergencyIntercom31SW</ProductString> <ProductString>IndoorIntercom31</ProductString> <ProductString>IndoorIntercom31SW</ProductString> <ProductString>IndoorKeypad31</ProductString> <ProductString>IndoorKeypad31SW</ProductString> <ProductString>OfficeRinger31</ProductString> <ProductString>OfficeRinger31SW</ProductString> <ProductString>OutdoorIntercom31</ProductString> <ProductString>OutdoorIntercom31SW</ProductString> <ProductString>OutdoorKeypad31</ProductString> <ProductString>OutdoorKeypad31SW</ProductString> <ProductString>Strobe31</ProductString> <ProductString>Strobe31SW</ProductString> Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 79 Configure the Autoprovisioning Parameters Autoprovisioning Example 1 Here's a simple example using four autoprovisioning files to configure two devices: We boot up two devices with mac addresses 00:20:f7:02:00:01 and 00:20:f7:02:00:02 (Device1 and Device2). The devices are set to use DHCP and that server provides an autoprovisioning server address with option 43. The address is “https://autoprovtest.server.net.” The files on this server are as follows: 000000cd.xml <MiscSettings> <DeviceName>CyberData Autoprovisioned</DeviceName> <AutoprovFile>sip_common.xml</AutoprovFile> <AutoprovFile>sip_[macaddress].xml</AutoprovFile> </MiscSettings> sip_common.xml <SIPSettings> <SIPServer>10.0.0.253</SIPServer> <RemoteSIPPort>5060</RemoteSIPPort> </SIPSettings> sip_0020f7020001.xml <SIPSettings> <SIPUserID>198</SIPUserID> <SIPAuthPassword>ext198</SIPAuthPassword> <DialoutExtension0>204</DialoutExtension0> </SIPSettings> sip_0020f7020002.xml <SIPSettings> <SIPUserID>500</SIPUserID> <SIPAuthPassword>ext500</SIPAuthPassword> <DialoutExtension0>555</DialoutExtension0> </SIPSettings> On boot, Device1 tries to fetch the file 0020f7023614.xml from “https://autoprovtest.server.net”. This file is not available, so device1 then tries to fetch the file 000000cd.xml. This file exists, and Device1 parses the three elements. 1. Device1 changes its device name to CyberData Autoprovisioned. 2. Device1 finds an AutoprovFile element containing the filename sip_common.xml. The device downloads sip_common.xml from “https://autoprovtest.server.net,” and imports this configuration, setting the sip server to 10.0.0.253 and the remote port to 5060.3. 3. Device1 finds another AutoprovFile element containing the filename sip_[macaddress].xml. The device replaces the [macaddress] with its own mac address value creating sip_0020f7020001.xml, downloads this file from “https://autoprovtest.server.net,” and imports this configuration. This sets the user ID to 198, the password to ext198, and the dialout extension to 204. Device1 is now finished with autoprovisioning. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 80 Configure the Autoprovisioning Parameters Device2 goes through the same steps by setting its device name to CyberData Autoprovisioned, its SIP server to 10.0.0.253, and its port to 5060. When Device2 “sees” sip_[macaddress].xml, Device2 replaces it with its own mac address and downloads sip_0020f7020002.xml from “https://autoprovtest.server.net.” Device2 sets the SIP User ID to 500, the password to ext500, and the dialout extension to 555. Autoprovisioning Example 2 Here is another example of setting up your autoprovisioning files: We boot up two devices with mac addresses 00:20:f7:02:00:01 and 00:20:f7:02:00:02 (Device1 and Device2) and boot them on a network with a DHCP server configured with an autoprovisioning server at 10.0.1.3 on option 150. Our TFTP server has three files: 0020f7020001.xml <MiscSettings> <AutoprovFile>common_settings.xml</AutoprovFile> </MiscSettings> <SIPSettings> <SIPUserID>198</SIPUserID> <SIPAuthPassword>ext198</SIPAuthPassword> <DialoutExtension0>204</DialoutExtension0> </SIPSettings> 0020f7020002.xml <MiscSettings> <AutoprovFile>common_settings.xml</AutoprovFile> </MiscSettings> <SIPSettings> <SIPUserID>500</SIPUserID> <SIPAuthPassword>ext500</SIPAuthPassword> <DialoutExtension0>555</DialoutExtension0> </SIPSettings> common_settings.xml <MiscSettings> <DeviceName>CyberData Autoprovisioned</DeviceName> </MiscSettings> <SIPSettings> <SIPServer>10.0.0.253</SIPServer> <RemoteSIPPort>5060</RemoteSIPPort> </SIPSettings> 1. On boot, Device1 downloads 0020f7020001.xml from 10.0.1.3 and imports these values. The SIP User ID is 198, the password is ext198, and the dialout extension is 204. 2. Device1 then gets the filename common_settings.xml from the AutoprovFile element and downloads this file from the TFTP server at 10.0.1.3. and imports these settings. The device name is set to CyberData Autoprovisioned, the SIP server is set to 10.0.0.253, and the port is set to 5060. Device2 does the same except it downloads 0020f7020002.xml on boot and imports these values instead. The Sip User ID is 500, password is ext500, and dialout extension is 555. Device2 then downloads the common_settings.xml file and imports those values. The device name is set to CyberData Autoprovisioned, the SIP server is set to 10.0.0.253, and the port is set to 5060. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 81 Configure the Autoprovisioning Parameters XML Files XML files can contain <AutoprovFile> elements. If multiple DHCP options are specified, the device will try to download autoprovisioning files from each in turn. The device will only look for <AutoprovFile> elements in the first file downloaded from each server. You can specify up to 20 <AutoprovFile> elements in the first autoprovisioning file. There are numerous ways to change an element of the configuration(xml) file. Using sip ext as an example, the extension can be changed: Within the device-specific xml, i.e. [macaddress].xml, via the AutoprovFile element:<SIPSettings>/<SIPExt> From the device specific xml, a pointer to a sip_common file From the device specific xml, a pointer to the device specific sip_[macaddress].xml From the common file, a pointer to sip_common.xml From the common file, a pointer to the device specific (sip_[macaddress].xml) Autoprovisioned Audio Files Audio files are stored in non-volatile memory and an autoprovisioned audio file will only have to be downloaded once for each device. Loading many audio files to the device from the web page could cause it to appear unresponsive. If this happens, wait until the transfer is complete and then refresh the page. The device uses the file name to determine when to download a new audio file. This means that if you used autoprovisioning to upload a file and then changed the contents of this file at the TFTP server, the device will not recognize that the file has changed (because the file name is the same). Since audio files are stored in non-volatile memory, if autoprovisioning is disabled after they have been loaded to the board, the audio file settings will not change. You can force a change to the audio files on the board by clicking Restore Default on the Audio Configuration page or by changing the autoprovisioning file with “default” set as the file name. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 82 Configure the Autoprovisioning Parameters 2.3.12.2 Sample dhcpd.conf # # Sample configuration file for ISC dhcpd for Debian # ddns-update-style none; option domain-name "voiplab"; option domain-name-servers 10.0.0.252; option option-150 code 150 = ip-address; option ntp-servers north-america.pool.ntp.org; option space VendorInfo; option VendorInfo.text code 10 = { text }; authoritative; log-facility local7; subnet 10.0.0.0 netmask 255.0.0.0 { max-lease-time 3600; default-lease-time 3600; option routers option subnet-mask 10.0.0.1; 255.0.0.0; option domain-name option domain-name-servers "voiplab"; 10.0.0.252; option time-offset -8; # Pacific Standard Time # option www-server 99.99.99.99; # # option tftp-server-name option tftp-server-name "10.0.1.52"; "http://test.cyberdata.net"; # OPTION 66 # OPTION 66 # option option-150 10.0.0.252; # OPTION 150 # These two lines are needed for option 43 # vendor-option-space VendorInfo; # option VendorInfo.text "http://test.cyberdata.net"; # OPTION 72 # OPTION 43 # OPTION 43 range 10.10.0.1 10.10.2.1; } Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 83 Configure the Autoprovisioning Parameters 2.3.12.3 Download Template Button The Download Template button allows the user to generate, download, edit, and then store an autoprovisioning template on the server that serves the autoprovisioning files for devices. To generate an autoprovisioning template directly from the device, complete the following steps: 1. On the Autoprovisioning page, click on the Download Template button. 2. You will see a window prompting you to save a configuration file (.xml) to a location on your computer (Figure 2-39). The configuration file is the basis for the default configuration settings for your unit). 3. Choose a location to save the configuration file and click on OK. See Figure 2-39. Figure 2-39. Configuration File 4. At this point, you can open and edit the autoprovisioning template to change the configuration settings in the template for the unit. 5. You can then upload the autoprovisioning file to a TFTP or HTTP server where the file can be loaded onto other devices. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 84 Downloading the Firmware 2.4 Upgrade the Firmware and Reboot the Singlewire InformaCast Loudspeaker Amplifier 2.4.1 Downloading the Firmware To download the firmware to your computer: 1. Download the latest firmware file from the Downloads tab at the following webpage: http://www.cyberdata.net/voip/011406/ 2. Unzip the firmware version file. This file may contain the following: • Firmware file • Release notes 3. Log in to the home page as instructed in Section 2.3.4, "Log in to the Configuration Home Page". 4. Click on the Firmware menu button to open the Firmware page. See Figure 2-40. Caution GENERAL ALERT Equipment Hazard: CyberData strongly recommends that you first reboot the device before attempting to upgrade the firmware of the device. See Section 2.4.2, "Reboot the Device". Figure 2-40. Firmware Page Singlewire V3.1 Paging Amplifier v11.6.3 5. Click on the Browse button, and then navigate to the location of the firmware file. 6. Select the firmware file. 7. Click on the Upload button. Note Operations Guide Do not reboot the device after clicking on the Upload button. 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 85 Downloading the Firmware Note This starts the upgrade process. Once the Singlewire InformaCast Loudspeaker Amplifier has uploaded the file, the Uploading Firmware countdown page appears, indicating that the firmware is being written to flash. The Singlewire InformaCast Loudspeaker Amplifier will automatically reboot when the upload is complete. When the countdown finishes, the Firmware page will refresh. The uploaded firmware filename should be displayed in the system configuration (indicating a successful upload and reboot). 8. Table 2-25 shows the web page items on the Firmware page. Table 2-25. Firmware Parameters Web Page Item Description Current Firmware Version Shows the current firmware version. Use the Browse button to navigate to the location of the firmware file that you want to upload. Click on the Upload button to automatically upload the selected firmware and reboot the system. Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 86 Reboot the Device 2.4.2 Reboot the Device To reboot a Singlewire InformaCast Loudspeaker Amplifier, log in to the web page as instructed in Section 2.3.4, "Log in to the Configuration Home Page". 1. Click on the Reboot button on the Home page (Figure 2-41). A normal restart will occur. Figure 2-41. Home Page 406100001 v11.6.3 Reboot Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 87 Command Interface Post Commands 2.5 Command Interface Some functions on the device can be activated using simple POST commands to the web interface. The examples in Table 2-26 use the free unix utility, wget, but any program that can send http POST commands to the device should work. 2.5.1 Command Interface Post Commands Note These commands require an authenticated session (a valid username and password to work). Table 2-26. Command Interface Post Commands Device Action HTTP Post Commanda Trigger relay (for configured delay) wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/command.cgi" --post-data "test_relay=yes" Place call to extension (example: extension 130) wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/command.cgi" --post-data "call=130" Terminate active call wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/command.cgi" --post-data "terminate=yes" Force reboot wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/command.cgi" --post-data "reboot=yes" Test Audio button wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/command.cgi" --post-data "test_audio=yes" Announce IP address wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/command.cgi" --post-data "speak_ip_address=yes" Play the "0" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_0=yes" Play the "1" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_1=yes" Play the "2" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_2=yes" Play the "3" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_3=yes" Play the "4" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_4=yes" Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 88 Command Interface Post Commands Table 2-26. Command Interface Post Commands (continued) Device Action HTTP Post Commanda Play the "5" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_5=yes" Play the "6" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_6=yes" Play the "7" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_7=yes" Play the "8" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_8=yes" Play the "9" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_9=yes" Play the "Dot" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_d=yes" Play the "Audio Test" audio file (from Audio Config) wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_audiotest=yes" Play the "Page Tone" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_pagetone=yes" Play the "Your IP Address Is" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_youripaddressis=yes" Play the "Rebooting" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_rebooting=yes" Play the "Restoring Default" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_restoringdefault=yes" Play the "Ringback tone" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_ringback=yes" Play the "Ring tone" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_ringtone=yes" Play the "Night Ring" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "play_nightring=yes" Delete the "0" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_0=yes" Delete the "1" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_1=yes" Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 89 Command Interface Post Commands Table 2-26. Command Interface Post Commands (continued) Device Action HTTP Post Commanda Delete the "2" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_2=yes" Delete the "3" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_3=yes" Delete the "4" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_4=yes" Delete the "5" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_5=yes" Delete the "6" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_6=yes" Delete the "7" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_7=yes" Delete the "8" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_8=yes" Delete the "9" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_9=yes" Delete the "Audio Test" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_audiotest=yes" Delete the "Page Tone" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_pagetone=yes" Delete the "Your IP Address Is" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_youripaddressis=yes" Delete the "Rebooting" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_rebooting=yes" Delete the "Restoring Default" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_restoringdefault=yes" Delete the "Ringback tone" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_ringback=yes" Delete the "Ring tone" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_ringtone=yes" Delete the "Night Ring" audio file wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/audiofiles.cgi" --post-data "delete_nightring=yes" Operations Guide 931281C CyberData Corporation Installing the Singlewire InformaCast Loudspeaker Amplifier 90 Command Interface Post Commands Table 2-26. Command Interface Post Commands (continued) Device Action HTTP Post Commanda Trigger the Sensor Test (Sensor Config page) wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgibin/sensor.cgi" --post-data "test=yes" a.Type and enter all of each http POST command on one line. Operations Guide 931281C CyberData Corporation 91 Appendix A: Mounting the Amplifier A.1 Mount the Amplifier Before you mount the enclosure, make sure that you have received all of the parts for each enclosure. Refer to Table A-1. Table A-1. Wall Mounting Components (Part of the Accessory Kit) Quantity Part Name 1 Mounting Accessory Kit which includes: Illustration (3) Plastic Ribbed Anchors (3) #8 Sheet Metal Screws 151147 #8x1.25" Truss Head Phillips Sheet Metal Screw (3x) 531032 Plastic Ribbed Anchor (3x) Operations Guide Note The Singlewire InformaCast Loudspeaker Amplifier was designed for indoor use. Mounting it on the external part of a building will require additional hardware for weatherproofing, cabling access, and lightning suppression. Consult a certified electrician for details. Note For mounting, use the three #8 SHEET METAL SCREWS to secure the enclosure. 931281C CyberData Corporation 92 Mount the Amplifier A.1.1 Mounting the Enclosure To mount the enclosure: 1. Prepare holes for the screws. 2. Plug in the power adapter and use the Power (PWR) LED to verify that the power is on. 3. Plug the ethernet cable into the device. The Link/Activity (Link/Act.) LED verifies the network connection. 4. For wall mounting, use the three #8 x 1-1/4-inch Truss Head Phillip screws to secure the speaker. See Figure A-1. Figure A-1. Mounting the Enclosure 151147 #8x1.25" Truss Head Phillips Sheet Metal Screw (3x) 531032 Plastic Ribbed Anchor (3x) Wiring the 125V AC Plug Caution GENERAL ALERT Operations Guide Equipment Caution: The green wire with the yellow stripe is a ground connection for Electrostatic Discharge (ESD) protection, and should not be removed. To wire the 125V AC plug, consult a licensed electrician and the local building codes in your area. 931281C CyberData Corporation 93 Appendix B: Setting up a TFTP Server B.1 Set up a TFTP Server Autoprovisioning requires a TFTP server for hosting the configuration file. B.1.1 In a LINUX Environment To set up a TFTP server on LINUX: 1. Create a directory dedicated to the TFTP server, and move the files to be uploaded to that directory. 2. Run the following command where /tftpboot/ is the path to the directory you created in Step 1: the directory that contains the files to be uploaded. For example: in.tftpd -l -s /tftpboot/your_directory_name B.1.2 In a Windows Environment You can find several options online for setting up a Windows TFTP server. This example explains how to use the Solarwinds freeware TFTP server, which you can download at: http://www.cyberdata.net/support/voip/solarwinds.html To set up a TFTP server on Windows: 1. Install and start the software. 2. Select File/Configure/Security tab/Transmit Only. 3. Make a note of the default directory name, and then move the firmware files to be uploaded to that directory. Operations Guide 931281C CyberData Corporation 94 Appendix C: Troubleshooting/Technical Support C.1 Frequently Asked Questions (FAQ) To see a list of frequently asked questions for your product, click on the FAQs tab at the following webpage: http://www.cyberdata.net/voip/011406/ C.2 Documentation The documentation for this product is released in an English language version only. To download PDF copies of CyberData product documentation, click on the Downloads tab at the following webpage: http://www.cyberdata.net/voip/011406/ Operations Guide 931281C CyberData Corporation 95 Contact Information C.3 Contact Information Contact CyberData Corporation 3 Justin Court Monterey, CA 93940 USA www.CyberData.net Phone: 800-CYBERDATA (800-292-3732) Fax: 831-373-4193 Sales Sales 831-373-2601, Extension 334 Technical Support The fastest way to get technical support for your VoIP product is to submit a VoIP Technical Support form at the following website: http://support.cyberdata.net/ The Support Form initiates a ticket which CyberData uses for tracking customer requests. Most importantly, the Support Form tells us which PBX system and software version that you are using, the make and model of the switch, and other important information. This information is essential for troubleshooting. Please also include as much detail as possible in the Comments section of the Support Form. Phone: (831) 373-2601, Extension 333 C.4 Warranty and RMA Information The most recent warranty and RMA information is available at the following website address: http://support.cyberdata.net/ Operations Guide 931281C CyberData Corporation 96 Index backup SIP server 2 45 backup SIP servers, SIP server backups 45 boost (volume) 33 Symbols #6 sheet metal screws 91 Numerics C 1 speaker configuration 11, 12 125V AC Plug (wiring) 92 16 gauge wire 11, 12 2 speaker configuration 12 802.3af mode 11, 12 802.3at compliance switch 11 802.3at mode 12 802.3at power injector (high power mode) 11 cabling 19 changing the web access password 32 Cisco SRST 45 command interface 87 commands 87 components 10 configurable parameters 33, 41, 45 configuration audio 61 default IP settings 24 door sensor 57 intrusion sensor 57 network 40 SIP 43 configuration home page 28 configuration page configurable parameters 33, 41 connecting the amplified outputs 11 connection options 13 connections 10, 13 connections inside of the NEMA box 10 contact information 95 contact information for CyberData 95 current network settings 41 CyberData contact information 95 A ac plug (wiring) 92 AC voltages 2 accessory kit 8, 91 activate relay (door sensor) 59 activity LED 20 address, configuration login 28 amplified outputs 11, 12 high power mode 12 how to use and connect 11 low power mode 11 announcing an IP address 21 audio configuration 61 night ring tone parameter 63 audio configuration page 61 audio encodings 4 audio files, user-created 64 audio test 21 autoprovision at time (HHMMSS) 73 autoprovision when idle (in minutes > 10) 73 autoprovisioning 74 download template button 74 autoprovisioning autoupdate (in minutes) 73 autoprovisioning configuration 72, 73 autoprovisioning filename 73 autoprovisioning server (IP Address) 73 D default gateway 9, 24 IP address 9, 24 subnet mask 9, 24 username and password 9, 24 web login username and password 28 default gateway 9, 24, 41 default IP settings 24 default login address 28 device configuration 32 device configuration parameters 73 the device configuration page 72 B backup SIP server 1 45 Operations Guide 931281C CyberData Corporation 97 device configuration page 32 device configuration parameters 33 device configuration password changing for web configuration access 32 DHCP Client 4 dial out extension (door sensor) 59 dial out extension strings 50 dial-out extension strings 52 dimensions 5 disable volume control dial 33 discovery utility program 28 distortion, total harmonic 5 DNS server 41 door sensor 57 activate relay 59 dial out extension 59 door sensor normally closed 59 play audio locally 59 download autoprovisioning template button 74 DTMF tones 50, 52 DTMF tones (using rfc2833) 50 home page 28 http POST command 87 http web-based configuration 4 E J enable night ring events 67 enclosure, mounting 91 ethernet I/F 5 event configuration enable night ring events 67 expiration time for SIP server lease 46, 48 export settings 30, 31 jumper descriptions 18 jumper locations 18 I identifier names (PST, EDT, IST, MUT) 38 identifying your product 1 illustration of amplifier mounting process 91 import settings 30, 31 import/export settings 30, 31 input specifications 5 installation 2 IP address 9, 24, 41 IP address announcement 21 IP address confirmation 21 IP addressing default IP addressing setting 9, 24 L lease, SIP server expiration time 46, 48 LEDs 20 lengthy pages 56 line input specifications 5 line output specifications 5 Linux, setting up a TFTP server on 93 local SIP port 46 log in address 28 loudspeaker type 19 loudspeaker, cabling/wiring 19 low power mode (amplified outputs) 11 F factory defaults 21 firmware where to get the latest firmware 84 G get autoprovisioning template 74 GMT table 38 GMT time 38 M H maximum wire length for two speaker configuration 12 MGROUP MGROUP Name 55 mounting an amplifier 91 multicast configuration 53, 61 Multicast IP Address 55 harmonic distortion 5 hazard levels 4 high power mode (amplified outputs) 12 Operations Guide 931281C CyberData Corporation 98 N product overview product features 3 product specifications 5 supported protocols 4 supported SIP servers 4 typical system installation 2 product specifications 5 protocols supported 4 navigation (web page) 25 navigation table 25 NEMA box components 10 network configuration 40 network link activity, verifying 20 nightring tones 56 Nightringer 83 nightringer settings 47 NTP server 33 R reboot 85, 86 remote SIP port 46 reset test function management switch 21 resetting the IP address to the default 91 restoring the factory defaults 21 ringtones 56 lengthy pages 56 rport discovery setting, disabling 46 RTFM switch 21 RTP/AVP 4 O one speaker configuration 11, 12 operating temperature 5 optional two speaker configuration 12 output impedance 5 output level 5 output signal amplitudes 5 output specifications 5 S P safety instructions 5 sales 95 sensor sensor normally closed 59 sensor timeout 59 sensor connection 14 sensor setup page 58 sensor setup parameters 57 sensors 59 server address, SIP 45 service 95 set time with external NTP server on boot 33 SIP enable SIP operation 45 local SIP port 46 user ID 45 SIP (session initiation protocol) 4 SIP configuration 43 SIP configuration parameters outbound proxy 46, 48 registration and expiration, SIP server lease 46, 48 unregister on reboot 46 user ID, SIP 45 SIP registration 45 SIP remote SIP port 46 SIP server 45 password for login 45 SIP servers supported 4 packet time 4 pages (lengthy) 56 parts list 7 password for SIP server login 45 login 28 restoring the default 9, 24 payload types 5 play audio locally (door sensor) 59 point-to-point configuration 51 polycom default channel 55 polycom emergency channel 55 polycom priority channel 55 port local SIP 46 remote SIP 46 posix timezone string timezone string 33 POST command 87 power input 5 power LED 20 power, connecting to paging amplifier 11 priority assigning 56 product mounting 91 parts list 7 product features 3 Operations Guide 931281C CyberData Corporation 99 unregister from 46 user ID for login 45 SIP server configuration 45 SIP volume 33 speaker cable 19 speaker configuration 11, 12 speaker configuration for two speakers 12 speaker wire 19 SRST 45 standard 1 speaker configuration 11, 12 status LED 20 subnet mask 9, 24, 41 supported protocols 4 volume dial 23 W warranty policy at CyberData 95 web access password 9, 24 web access username 9, 24 web configuration log in address 28 web page navigation 25 web page navigation 25 wget, free unix utility 87 Windows, setting up a TFTP server on 93 wire gauge 11, 12 wire length going to wire nuts for two speaker configuration 12 wire nuts to connect wire 11, 12 wiring 19 wiring (ac plug) 92 T tech support 95 technical support, contact information 95 test audio 21 TFTP server 4, 93 time zone string examples 38 two speaker configuration 12 U user ID for SIP server login 45 username changing for web configuration access 32 default for web configuration access 28 restoring the default 9, 24 using the amplified outputs 11 V verifying network link and activity 20 power on 20 VLAN ID 41 VLAN Priority 41 VLAN tagging support 41 VLAN tags 41 volume 23 multicast volume 33 ring volume 33 sensor volume 33 SIP volume 33 volume adjustment 22 volume boost 33 volume control dial disable 33 Operations Guide 931281C CyberData Corporation
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project