advertisement
▼
Scroll to page 2
of 12
SST 1 Soft-starting tool 1 SST 3 replaces SST 1 Instruction manual 0740 800 165 090831 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Soft starting CaddyArc 150, CaddyTig 150, OrigoTig 150, OrigoArc 150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Soft starting OrigoArc 200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Soft starting CaddyTig 200, OrigoTig 200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Checking the gate pulses CaddyArc 150, CaddyTig 150, CaddyTig 200, OrigoTig 150, OrigoTig 200 . . . . . . . . . . . . . . . 10 Checking the gate pulses OrigoArc 150, OrigoArc 200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Rights reserved to alter specifications without notice. conte -2- Introduction Soft-starting tool SST 1 The soft-starting tool is intended for use by technicians with electrical/electronic training for help in connection with fault-tracing and repair. The SST 1 is made for the CaddyArc, CaddyTig, OrigoTig and OrigoArc. It can be ordered from ESAB, ordering no. 0459 534 880. The tool includes: Soft starting rectifier, cable set, voltage test board, gate pulse load and shunt voltage resistor for the OrigoArc. This manual describes the soft-starting procedure for the CaddyArc, CaddyTig, OrigoTig and OrigoArc. Complete service manuals for the machines have the following filename / ordering no: 0740 0740 0740 0740 800 800 800 800 161 162 163 164 CaddyArc 150, CaddyTig 150, OrigoTig 150 OrigoArc 150 OrigoArc 200 CaddyTig 200, OrigoTig 200 Note! The SST 3 replaces SST 1. The SST 3 is made for ESAB's single phase inverters and for 3-phase inverters with 250 A output current. The difference in function is that the SST 1 can only be used for single phase inverters. The instruction manual for the SST 3 has ordering no. / filename: 0740 800 204. csst1d1 -3- S0740 800 165/E090831/P12 CaddyArc 150, CaddyTig 150, OrigoArc 150, OrigoTig 150 Soft starting We recommend soft starting of the machine after replacing control circuit board 20AP1, power supply board 2AP1 and circuit boards or components in the power module. Soft starting supplies the power module with a low voltage in order to avoid injury to persons or damage to components. It is a good idea to use soft starting when fault tracing. Special equipment To soft-start the machine you need soft-starting tool SST 1, this is described on page 3. Instructions 1. Disconnect wires 1501, 1502, 1503 and 1504 from circuit boards 2AP1 and 15AP1. Disconnections prior to soft starting 2. 3. Connect the 230 V AC input of the SST 1 to terminals B1 and B2 on circuit board 2AP1. Connect the 325 V DC output of the SST 1 to terminals F1 and F3 on circuit board 2AP1. The SST 1 connected to 2AP1 4. 5. 6. 7. 8. Disconnect connector 20XS4 from terminal PS of power supply board 2AP1. Connect the voltage test cable of the SST 1 to terminal PS of power supply board 2AP1. Connect the power source to the mains and turn on the mains switch. Verify the output voltages from 2AP1, all LEDs must light. (OrigoArc: only the +24V LED must light). Switch off the machine. Disconnect the voltage test cable and reconnect connector 20XS4 to terminal PS of circuit board 2AP1. Disconnect connector 15XS3 (supply to the fan) from terminal E of circuit board 2AP1. Connect the 24 V DC input of the SST1 to terminal E of circuit board 2AP1. csst1t27f4soft -4- S0740 800 165/E090831/P12 CaddyArc 150, CaddyTig 150, OrigoArc 150, OrigoTig 150 9. Connect the 24 V DC output of the SST 1 to terminals C1 and C2 of power board 15AP1. Circuit connections and measuring points for soft starting 10. 11. 12. 13. Switch on the machine and set it to MMA mode. Check that the DC voltage across smoothing capacitor 15C1 is 22-24 V. Check that the DC voltage at the welding terminals is 7-8 V. If all the measurements are as described above, reconnect the wires to restore the power source to normal operation mode and make a test weld. csst1t27f4soft -5- S0740 800 165/E090831/P12 OrigoArc 200 Soft starting We recommend soft starting of the machine after replacing control circuit board 20AP1, power supply board 2AP1 and circuit boards or components in the power module. Soft starting supplies the power module with a low voltage in order to avoid injury to persons or damage to components. It is a good idea to use soft starting when fault tracing. Special equipment To soft-start the machine you need soft-starting tool SST 1, this is described on page 3. Instructions 1. Disconnect wires 1501, 1502, 1505, 1506, 1503 and 1504 from circuit boards 2AP2, 2AP1 and 15AP1. Disconnections prior to soft starting 2. 3. Connect the 230 V AC input of the SST 1 to terminals C1 and C3 on circuit board 2AP2. Connect the 325 V DC output of the SST 1 to terminals F1 and F3 on circuit board 2AP1. The SST 1 connected to 2AP2 and 2AP1 4. 5. 6. 7. Disconnect connector 20XS4 from terminal PS of power supply board 2AP1. Connect the voltage test cable of the SST 1 to terminal PS of power supply board 2AP1. Connect the power source to the mains and turn on the mains switch. Verify the output voltage from 2AP1, the +24 V LED must light. (The voltage must be +24 V $0.6 V.) Switch off the machine. Disconnect the voltage test cable and reconnect connector 20XS4 to terminal PS of power supply board 2AP1. csst1h25bf4soft -6- S0740 800 165/E090831/P12 OrigoArc 200 8. 9. Disconnect connector 15XS3 (supply to the fan) from terminal E of circuit board 2AP1. Connect the 24 V DC input of the SST 1 to terminal E of circuit board 2AP1. Connect the 24 V DC output of the SST 1 to terminals N1:1 and N2:1 of power board 15AP1. Circuit connections and measuring points for soft starting 10. 11. 12. 13. Switch on the machine. Check that the DC voltage across smoothing capacitor 15C1 is 22-24 V. Check that the DC voltage at the welding terminals is 7-8 V. If all the measurements are as described above, reconnect the wires to restore the power source to normal operation mode and make a test weld. csst1h25bf4soft -7- S0740 800 165/E090831/P12 CaddyTig 200, OrigoTig 200 Soft starting We recommend soft starting of the machine after replacing control circuit board 20AP1, power supply board 2AP1 and circuit boards or components in the power module. Soft starting supplies the power module with a low voltage in order to avoid injury to persons or damage to components. It is a good idea to use soft starting when fault tracing. Special equipment To soft-start the machine you need soft-starting tool SST 1, this is described on page 3. Instructions 1. Disconnect wires 1501, 1502, 1503 and 1504 from circuit boards 2AP1 and 15AP1. Disconnections prior to soft starting 2. 3. Connect the 230 V AC input of the SST 1 to terminals B1 and B2 on circuit board 2AP1. Connect the 325 V DC output of the SST 1 to terminals F1 and F3 on circuit board 2AP1. The SST 1 connected to 2AP1 4. 5. 6. 7. 8. Disconnect connector 20XS4 from terminal PS of power supply board 2AP1. Connect the voltage test cable of the SST 1 to terminal PS of power supply board 2AP1. Connect the power source to the mains and turn on the mains switch. Verify the output voltages from 2AP1, all LEDs on the SST 1 must light. Switch off the machine. Disconnect the voltage test cable and reconnect connector 20XS4 to terminal PS of circuit board 2AP1. Disconnect connector 15XS3 (supply to the fan) from terminal E of circuit board 2AP1. Connect the 24 V DC input of the SST 1 to terminal E of circuit board 2AP1. csst1t27bf4soft -8- S0740 800 165/E090831/P12 CaddyTig 200, OrigoTig 200 9. Connect the 24 V DC output of the SST 1 to terminals N1:1 and N2:1 of power board 15AP1. Circuit connections and measuring points for soft starting 10. 11. 12. 13. Switch on the machine and set it to MMA mode. Check that the DC voltage across smoothing capacitor 15C1 is 22-24 V. Check that the DC voltage at the welding terminals is about 7-8 V. If all the measurements are as described above, reconnect the wires to restore the power source to normal operation mode and make a test weld. csst1t27bf4soft -9- S0740 800 165/E090831/P12 CaddyArc 150, CaddyTig 150, CaddyTig 200, OrigoTig 150, OrigoTig 200 Checking the gate pulses When checking the gate pulses, the machine can either be in soft-start mode or in normal operation mode. Special equipment To measure the gate pulses, you need a gate pulse load. This is included in soft-starting tool SST 1, which is described on page 3. Instructions 1. 2. 3. Disconnect the machine from the mains. Disconnect connector 20XS5 from terminal G on control board 20AP1. Connect the gate pulse test cable of the SST 1 to terminal G on control board 20AP1. Measuring connection for the gate pulses 4. 5. 6. 7. 8. 9. Switch on the machine. Connect an oscilloscope to the SST 1, with the probe to terminal G2 and the screen to terminal G1 of SST1. Set the machine to MMA welding mode. Measure the pulse frequency. It must be 65 kHz +/- 1kHz. Measure the duration of the negative pulse. It must be 41 - 43 % of the cycle time, measured at a voltage level of -10 V. The waveform of the pulses must be as shown below. Gate pulses from circuit board 20AP1 csst1t27f5gate - 10 - S0740 800 165/E090831/P12 OrigoArc 150, OrigoArc 200 Checking the gate pulses When checking the gate pulses, the machine can either be in soft-start mode or in normal operation mode. Special equipment To measure the gate pulses, you need a gate pulse load and a shunt voltage resistor. This is included in soft-starting tool SST 1, which is described on page 3. Instructions 1. Disconnect the machine from the mains. 2. Disconnect connector 15XS8 from terminal S on control board 20AP1. 3. Connect the cable marked “20AP1 S1, S2” to terminal S. Shunt voltage resistor connected to terminal S 4. Disconnect connector 20XS5 from terminal G on control board 20AP1. 5. Connect the gate pulse test cable of the SST 1 to terminal G on control board 20AP1. 6. Switch on the machine. 7. Connect an oscilloscope to the SST 1, with the probe to terminal G2 and the screen to Measuring connection for the gate pulses terminal G1. 8. Set the current reference to 70 A or more. This will set the pulses to maximum pulse width. At minimum current reference, there are no pulses. 9. Measure the pulse frequency. It must be 65 kHz +/- 1kHz. 10. Measure the duration of the negative pulse. It must be 41 - 43 % of the cycle time, measured at a voltage level of -10 V. 11. The waveform of the pulses must be as shown below. Gate pulses from circuit board 20AP1 csst1h25f5gate - 11 - S0740 800 165/E090831/P12 ESAB subsidiaries and representative offices Europe AUSTRIA ESAB Ges.m.b.H Vienna-Liesing Tel: +43 1 888 25 11 Fax: +43 1 888 25 11 85 BELGIUM S.A. ESAB N.V. Brussels Tel: +32 2 745 11 00 Fax: +32 2 745 11 28 THE CZECH REPUBLIC ESAB VAMBERK s.r.o. Vamberk Tel: +420 2 819 40 885 Fax: +420 2 819 40 120 DENMARK Aktieselskabet ESAB Herlev Tel: +45 36 30 01 11 Fax: +45 36 30 40 03 FINLAND ESAB Oy Helsinki Tel: +358 9 547 761 Fax: +358 9 547 77 71 FRANCE ESAB France S.A. Cergy Pontoise Tel: +33 1 30 75 55 00 Fax: +33 1 30 75 55 24 GERMANY ESAB GmbH Solingen Tel: +49 212 298 0 Fax: +49 212 298 218 GREAT BRITAIN ESAB Group (UK) Ltd Waltham Cross Tel: +44 1992 76 85 15 Fax: +44 1992 71 58 03 ESAB Automation Ltd Andover Tel: +44 1264 33 22 33 Fax: +44 1264 33 20 74 HUNGARY ESAB Kft Budapest Tel: +36 1 20 44 182 Fax: +36 1 20 44 186 ITALY ESAB Saldatura S.p.A. Mesero (Mi) Tel: +39 02 97 96 81 Fax: +39 02 97 28 91 81 THE NETHERLANDS ESAB Nederland B.V. Amersfoort Tel: +31 33 422 35 55 Fax: +31 33 422 35 44 NORWAY AS ESAB Larvik Tel: +47 33 12 10 00 Fax: +47 33 11 52 03 POLAND ESAB Sp.zo.o. Katowice Tel: +48 32 351 11 00 Fax: +48 32 351 11 20 PORTUGAL ESAB Lda Lisbon Tel: +351 8 310 960 Fax: +351 1 859 1277 SLOVAKIA ESAB Slovakia s.r.o. Bratislava Tel: +421 7 44 88 24 26 Fax: +421 7 44 88 87 41 SPAIN ESAB Ibérica S.A. Alcalá de Henares (MADRID) Tel: +34 91 878 3600 Fax: +34 91 802 3461 SWEDEN ESAB Sverige AB Gothenburg Tel: +46 31 50 95 00 Fax: +46 31 50 92 22 ESAB international AB Gothenburg Tel: +46 31 50 90 00 Fax: +46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel: +41 1 741 25 25 Fax: +41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Tel: +54 11 4 753 4039 Fax: +54 11 4 753 6313 Asia/Pacific Representative offices CHINA Shanghai ESAB A/P Shanghai Tel: +86 21 2326 3000 Fax: +86 21 6566 6622 BULGARIA ESAB Representative Office Sofia Tel/Fax: +359 2 974 42 88 INDIA ESAB India Ltd Calcutta Tel: +91 33 478 45 17 Fax: +91 33 468 18 80 INDONESIA P.T. ESABindo Pratama Jakarta Tel: +62 21 460 0188 Fax: +62 21 461 2929 JAPAN ESAB Japan Tokyo Tel: +81 45 670 7073 Fax: +81 45 670 7001 MALAYSIA ESAB (Malaysia) Snd Bhd USJ Tel: +603 8023 7835 Fax: +603 8023 0225 SINGAPORE ESAB Asia/Pacific Pte Ltd Singapore Tel: +65 6861 43 22 Fax: +65 6861 31 95 EGYPT ESAB Egypt Dokki-Cairo Tel: +20 2 390 96 69 Fax: +20 2 393 32 13 ROMANIA ESAB Representative Office Bucharest Tel/Fax: +40 1 322 36 74 RUSSIA LLC ESAB Moscow Tel: +7 095 543 9281 Fax: +7 095 543 9280 LLC ESAB St Petersburg Tel: +7 812 336 7080 Fax: +7 812 336 7060 Distributors For addresses and phone numbers to our distributors in other countries, please visit our home page www.esab.com SOUTH KOREA ESAB SeAH Corporation Kyungnam Tel: +82 55 269 8170 Fax: +82 55 289 8864 UNITED ARAB EMIRATES ESAB Middle East FZE Dubai Tel: +971 4 887 21 11 Fax: +971 4 887 22 63 BRAZIL ESAB S.A. Contagem-MG Tel: +55 31 2191 4333 Fax: +55 31 2191 4440 CANADA ESAB Group Canada Inc. Missisauga, Ontario Tel: +1 905 670 02 20 Fax: +1 905 670 48 79 MEXICO ESAB Mexico S.A. Monterrey Tel: +52 8 350 5959 Fax: +52 8 350 7554 USA ESAB Welding & Cutting Products Florence, SC Tel: +1 843 669 44 11 Fax: +1 843 664 57 48 ESAB AB SE-695 81 LAXÅ SWEDEN Phone +46 584 81 000 www.esab.com 081016
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement