Omega iDRN-PS-1000 User`s guide

Add to My manuals
20 Pages

advertisement

Omega iDRN-PS-1000 User`s guide | Manualzz

L N

User’s Guide

Shop on line at

® ®

www.omega.com

e-mail: [email protected]

+ iDRN-PS-1000

UNIVERSAL SWITCHING POWER SUPPLY Compact DIN-Rail 24 Volt

OMEGAnet SM On-Line Service http://www.omega.com Internet e-mail [email protected]

USA: ISO 9001 Certified Canada: Servicing North America: One Omega Drive, P.O. Box 4047 Stamford, CT 06907-0047 TEL: (203) 359-1660 e-mail: [email protected]

976 Bergar Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 e-mail: [email protected]

FAX: (203) 359-7700 FAX: (514) 856-6886 For immediate technical or application assistance: USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA Customer Service: 1-800-622-2378 / 1-800-622-BEST Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

omega.com

® ® ® Mexico TEL: (001)800-TC-OMEGA SM En Español: (001) 203-359-7803 FAX: (001) 203-359-7807 e-mail: [email protected]

Benelux: Servicing Europe: Postbus 8034, 1180 LA Amstelveen, The Netherlands TEL: +31 (0)20 6418405 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: [email protected]

Czech Republic: France: Rudé armády 1868, 733 01 Karviná 8 TEL: +420 (0)69 6311899 FAX: +420 (0)69 6311114 e-mail: [email protected]

9, rue Denis Papin, 78190 Trappes TEL: +33 (0)130 621 400 Toll Free in France: 0800406342 e-mail: [email protected]

FAX: +33 (0)130 699 120 Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany TEL: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 TC-OMEGA SM e-mail: [email protected]

United Kingdom: ISO 9002 Certified One Omega Drive River Bend Technology Centre Northbank, Irlam Manchester M44 5EX United Kingdom TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in the UK: 0800 488 488 e-mail: [email protected]

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the mark to every appropriate device upon certification.

The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.

WARNING: These products are not designed for use in, and should not be used for, patient connected applications.

This device is marked with the international caution symbol. It is important to read the Setup Guide before installing or commissioning this device as it contains important information relating to safety and EMC.

1.

2.

3.

4.

5.

6.

7.

General Information and Features Safety Considerations Installation and Removal 3.1 Installation Clearance 3.2 Mounting on DIN Rail 3.3 Removal of Unit Input and Output Connections 4.1 Block Diagram 4.2 Wiring for 115 Vac - Single Phase 4.3 Wiring for 230 Vac - Two Phase Specifications Input Power Output Power General Wire Connections Dimensions Temperature Derating Graph C

ONTENTS

2 3 4 5 6 7 8 8 9 10 11 11 11 12 12 13 14 1

2 1 G

ENERAL

I

NFORMATION AND

F

EATURES

The compact iDRN power supplies are designed to supply well-regulated 24 volt DC power to sensors, signal conditioners, data acquisition systems and high level logic equipment.

Features

• • • • • • • • • Significant iDRN features include: • Tested isolation, primary to output Recessed live parts and connector screws 35mm DIN rail mounting Wide input voltage tolerances Protective varistor input shunt Input AC spike rejection with LC filters LED power-on lamp Over-temperature protection Short circuit protection Low-ripple, well-regulated design

S

AFETY

C

ONSIDERATIONS

2 This device is marked with the international Caution symbol. It is important to read this manual before installing or commissioning this device as it contains important information relating to Safety and EMC (Electromagnetic Compatibility).

Unpacking & Inspection Unpack the instrument and inspect for obvious shipping damage. Do not attempt to operate the unit if damage is found.

This instrument is a DIN rail mount device. Installation of this instrument should be done by Qualified personnel. In order to ensure safe operation, the following instructions should be followed.

This instrument has no power-on switch. An external switch or circuit-breaker shall be included in the building installation as a disconnecting device. It shall be marked to indicate this function, and it shall be in close proximity to the equipment within easy reach of the operator. The switch or circuit-breaker shall not interrupt the Protective Conductor (Earth wire), and it shall meet the relevant requirements of IEC 947–1 and IEC 947-3 (International Electrotechnical Commission). The switch shall not be incorporated in the mains supply cord.

Furthermore, to provide protection against excessive energy being drawn from the mains supply in case of a fault in the equipment, an overcurrent protection device shall be installed.

• The Protective Conductor must be connected for safety reasons. Check that the power cable has the proper Earth wire, and it is properly connected. It is not safe to operate this unit without the Protective Conductor Terminal connected.

• • • • • • • Do not exceed voltage rating on the label located on the top of the instrument housing.

Always disconnect power before changing signal and power connections.

Do not use this instrument on a work bench without its case for safety reasons.

Do not operate this instrument in flammable or explosive atmospheres.

Do not expose this instrument to rain or moisture.

Unit mounting should allow for adequate ventilation to ensure instrument does not exceed operating temperature rating.

Use electrical wires with adequate size to handle mechanical strain and power requirements. Install without exposing bare wire outside the connector to minimize electrical shock hazards.

• • EMC Considerations • • Whenever EMC is an issue, always use shielded cables.

Never run signal and power wires in the same conduit.

Use signal wire connections with twisted-pair cables.

Install Ferrite Bead(s) on signal wires close to the instrument if EMC problems persist.

3

3 I

NSTALLATION AND

R

EMOVAL

Warning!

If a rail assembly is to be transported, then disconnection, dismounting and separate packing of the power supply is recommended.

For units that must be shipped installed on the rail, additional bracing to resist transportation shocks is recommended.

Do not attempt to install or connect to the power supply when the mains are energized.

4

I

NSTALLATION AND

R

EMOVAL

3 3.1 Installation Clearance Ensure that there is enough room for mounting the power supply unit. There should be a minimum of 1" [25mm] spacing to allow sufficient air circulation for proper cooling.

1" [25mm] 1" [25mm]

AC POWER IN SIGNAL INPUT DC POWER IN SIGNAL INPUT DC POWER IN

DIN RAIL SIGNAL CONDITIONER MODULES 24V-BUS

DC POWER OUT

POWER SUPPLY

SIGNAL INPUT DC POWER IN

Figure 3.1 — Mounting 5

3 I

NSTALLATION AND

R

EMOVAL

3.2 Mounting on DIN Rail To install unit onto DIN Rail 1. Tilt unit, position mounting slot onto DIN Rail, as shown.

2. Push unit towards DIN Rail and it will snap into place.

6 Figure 3.2 — Mounting on 35mm DIN Rail

I

NSTALLATION AND

R

EMOVAL

3.3 Removal of Unit 1. Insert flat screw-driver into tab and push downwards.

2. Unit will detach from DIN Rail.

3 Figure 3.3 — Removal of Unit 7

4 I

NPUT AND

O

UTPUT

C

ONNECTIONS

4.1 Block Diagram of Power Supply Figure 4.1 — Block Diagram 4.2 Wiring Warning: Do not turn on the ac power to the power supply unit until you have completed all output connections. Failure to do so may result in injury!

This device must only be installed electrically by a specially trained electrician with corresponding qualifications.

Warning: To avoid potential electric shock use National Electrical Code (NEC) safety practices when wiring and connecting this unit to a power source.

8

I

NPUT AND

O

UTPUT

C

ONNECTIONS

4.2 Wiring (Continued) 115Vac - Single phase power wiring

FUSE 1 Switch LINE NEUTRAL Earth

4

Input Power USE AWG 12-26 WIRE

L N

Earth * USE A SWITCH TO APPLY +24V POWER TO THE LOAD, IF THE CAPACITANCE OF THE LOAD WILL DRAW MORE THAN 7 AMPS AT TURN ON.

Output Voltage

+ -

(for shielded wire connections, if necessary) Earth Return +24 V * Switch To Signal Conditioner Modules

Figure 4.2— Wiring for 115Vac - Single Phase 9

4 I

NPUT AND

O

UTPUT

C

ONNECTIONS

4.3 Wiring (Continued) 230Vac - Two phase power wiring

FUSE 1 Switch L1 L 2 Earth FUSE 2 Input Power USE AWG 12-26 WIRE Earth

L N 10

* USE A SWITCH TO APPLY +24V POWER TO THE LOAD, IF THE CAPACITANCE OF THE LOAD WILL DRAW MORE THAN 7 AMPS AT TURN ON.

Output Voltage

+ -

(for shielded wire connections, if necessary) Earth Return +24 V * Switch To Signal Conditioner Modules

Figure 4.3— Wiring for 230Vac - Two Phase

S

PECIFICATIONS

5

INPUT POWER

Input Voltage: Frequency: 115 - 240Vac ±10% 50/60 Hz Current: 0.400A @ 103Vac 0.190A @ 265Vac Overvoltage Protection: 275 Volt Varistor Overcurrent Protection: Fuse TR-5 800mA Time-lag / IEC 127-3 Input Wattage: 26 Watts

OUTPUT POWER

Output Voltage: Output Wattage: 24Vdc ±2% @ 850mA (Resistive Load) 20 Watts* * For higher output wattage greater than 20 watts follow the chart on section 7, Figure 6.2.

Ripple: less than 100 mVrms Operating Indicator: Front Panel LED Short-Circuit/ Overload Protection: Current limiting with automatic short circuit protection and temperature shutdown accomplished by the switcher.

Maximum number of Signal Conditioner modules powered: Depends on module used and configuration (6-10 modules) 11

5 S

PECIFICATIONS GENERAL

Operating Temperature: Storage Temperature: Mounting: Size: Weight: Equipment Type: Overvoltage: Pollution Degree: 23° to 122°F(-5° to 50°C) -40° to 176°F(-40° to 80°C) 35mm DIN Rail Height: 3.55" Width: Depth: 0.99" 4.38" 0.3 lbs. (0.14 kg) CLASS I CAT II 2 (90mm) (25mm) (111mm) Insulation input to ouput: Dielectric strength to 2500V transient based on EN61010 for 265Vrms working voltage

WIRE CONNECTIONS

Screw down wire clamps, AWG 12 to 26 (ferrules recommended for stranded wire).

12

D

IMENSIONS

6 13

7 I

NPUT AC VOLTAGE

/

POWER OUTPUT

AC INPUT CURRENT @ 100VAC INPUT OUTPUT POWER AC CURRENT 20W 21W 22W 23W 24W 338mA 355mA 373mA 392mA 412mA

MAXIMUM POWER OUTPUT 24W 23W 22W 21W 120V 265V INPUT AC VOLTAGE 115V 110V 105V 100V 20W -5ºC 30ºC 35ºC 40ºC 45ºC 50ºC AMBIENT TEMPERATURE ºC 25ºC

Example: If ambient is 50ºC, maximum wattage is 21W max. for 120-265Vac. If unit is operated at 21W at an input voltage of 100V, the maximum ambient temperature allowed is 40ºC.

Figure 6.2 — Temperature Derating Graph 14

NOTES

15

16

NOTES

WARRANTY/DISCLAIMER

USA

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS / INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.

BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY the following information available BEFORE contacting OMEGA: RETURNS, please have 1. P.O. number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product.

FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. P.O. number to cover the COST of the repair, 2. Model and serial number of product, and 3. Repair instructions and/or specific problems relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.

OMEGA is a registered trademark of OMEGA ENGINEERING, INC.

© Copyright 2002 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.

PATENT NOTICE: This product is covered by one or more of the following patents: U.S. Pat. No. Des. 336,895; 5,274,577 / Canada 2052599; 2052600 / Italy 1249456; 1250938 / France Brevet No. 91 12756 / Spain 2039150; 2048066 / UK Patent No. GB2 249 837; GB2 248 954 / Germany DE 41 34398 C2 Used Under License. Other International Patents Pending.

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course!

Shop on line at www.omega.com

TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers & Strain Gauges Load Cells & Pressure Gauges Displacement Transducers Instrumentation & Accessories FLOW/LEVEL Rotameters, Gas Mass Flowmeters & Flow Computers Air Velocity Indicators Turbine/Paddlewheel Systems Totalizers & Batch Controllers pH/CONDUCTIVITY pH Electrodes, Testers & Accessories Benchtop/Laboratory Meters Controllers, Calibrators, Simulators & Pumps Industrial pH & Conductivity Equipment DATA ACQUISITION Data Acquisition & Engineering Software Communications-Based Acquisition Systems Plug-in Cards for Apple, IBM & Compatibles Datalogging Systems Recorders, Printers & Plotters HEATERS Heating Cable Cartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL Metering & Control Instrumentation Refractometers Pumps & Tubing Air, Soil & Water Monitors Industrial Water & Wastewater Treatment pH, Conductivity & Dissolved Oxygen Instruments M2540/0202

advertisement

Related manuals

advertisement