PRG 350 Series Stainless Steel Regulators

Installation, Operation and Maintenance Instructions

PRG 350SS 1/2" NPT

Bonnet Range Spring * Pintle Assembly * Housing Seal O-Ring * Filter O-Ring (2) Drip Well Housing Assembly Filter Retainer *Included with repair kit M-4808/ 0916 Adjustment Screw Assembly Spring Guide *Diaphragm Assembly Body Assembly Collar Filter, 25 Micron, SS Pintle Spring Filter Retaining Screw

Contents

Section Description

1.0

2.0

3.0

4.0

5.0

Specifications Installation Operation Maintenance & Repair Warranty

Page

2 2 3 3 5 PRG 350 Series Page 1

DANGER, WARNING, CAUTION and NOTE statements

DANGER Refers to conditions or hazards which could result in serious personal injury or death.

WARNING Refers to conditions or hazards which could result in personal injury.

CAUTION Refers to conditions or hazards which could result in equipment or property damage.

NOTE Alerts you to facts or special instructions.

ALL DANGER, WARNING, AND CAUTION NOTICES MUST BE COMPLIED WITH IN FULL DANGER Personal injury, property damage, equipment damage, or leakage due to escaping gas or bursting of pressure containing parts may result if this regulator is over pressurized or installed where service conditions could exceed the limits given in the specifications. To avoid such injury or damage, provide pressure-relieving or limiting devices (as required by the appropriate code, regulation or standard) to prevent service conditions from exceeding those limits.

1. SPECIFICATIONS

Output Ranges: Exhaust Capacity: Maximum Supply Pressure: Air Consumption: Operating Temperatures: Filter: Porting: Materials: Weight:

0-30 psig (0-2.0 BAR), 0-60 psig (0-4.0 BAR), 0-100 psig (0-7.0 BAR), 0-150 psig (0-10.0 BAR) 1.0 SCFM (1.7 m3/hr) at downstream pressure of 10 psig (0.7 BAR) above set point 290 psig (20.0 BAR) 4 SCFH (0.1 m3/hr) -20° to +185° F (-29° to +85° C) 25 micron Inlet/Outlet: 1/4" NPT or 1/2" NPT Gauge (2): 1/4" NPT Exhaust: 1/8" NPT 316 stainless steel: Fluorocarbon: Inconel: 1/4" NPT: 2.2 lbs. (1.0 kg) 1/2" NPT: 2.8 lbs. (1.3 kg) body, bonnet, filter diaphragm, seals range spring, pintle spring

2. INSTALLATION

2.1

Install the regulator/filter as close as possible to the instrument or tool it is to service.

2.2

Clean all pipelines to remove dirt and scale prior to installation.

NOTE Failures attributable to air supply contamination are not covered by the warranty.

WARNING This instrument vents to atmosphere. The use of gas other than air may create a hazardous environment.

2.3

Install the regulator/filter so that the direction of flow is from the "IN" to "OUT" connec tion as marked on the body of the regulator/filter.

M-4808/ 0916 PRG 350 Series Page 2

2.4

For best drainage, orient the drain valve so that it is at the lowest point on the drip well housing. Positioning of the drain valve may be improved by rotating the drip well with respect to the body.

2.5

The exhaust port should be kept free and unplugged. Position the regulator so that the vent is at the lowest point possible, or provide additional protection to prevent contami nants from entering the regulator. Rotating the bonnet relative to the body may change the vent hole orientation.

WARNING The PRG 350 Series has a low capacity internal relief that provides limited down stream protection against over pressurization.

2.6

Exhaust may be remotely vented by installing tubing to the 1/8" NPT port.

2.7

Apply pipe compound or sealing tape to the male pipe threads prior to installing regulator/filter. Use caution to prevent the sealant from getting inside the regulator/filter.

3. OPERATION

3.1

Prior to turning on supply air, back off adjusting screw until there is no compression of the range spring.

3.2

After applying the air supply, output pressure will be increased by rotating the adjust ment screw clockwise. Pressure can be decreased by turning counter clockwise.

3.3

Tighten locknut to maintain desired pressure setting.

4. MAINTENANCE & REPAIR

4.1

To remove condensate from the PRG 350 Series, slowly open drain valve by turning clockwise and bleed accumulated liquid.

DANGER To avoid personal injury, property damage, or equipment damage caused by sudden release of pres sure or explosion of accumulated gas, do not attempt any maintenance or disassembly without first isolating the regulator from system pressure and relieving all internal pressure from the regulator.

4.2 To clean filter element

4.2.1 Shut off supply pressure and relieve all internal pressure.

4.2.2 Drain condensate from drip well.

4.2.3 Remove four corner bolts from bottom of unit and remove drip well housing.

4.2.4 Remove filter retaining screw.

4.2.5 Remove filter retainer, filter o-ring seals and filter.

4.2.6 Clean parts and reassemble in reverse order.

4.3 To clean/replace pintle assembly

4.3.1 Follow steps 4.2.1 through 4.2.4.

4.3.2 Unscrew collar and remove.

4.3.3 Remove pintle spring and pintle. 1/4" NPT version may require needle nose pliers or push pintle stem from above by removing bonnet and diaphragm assembly.

4.3.4 Clean/replace parts and reassemble in reverse order.

M-4808/0 916 PRG 350 Series Page 3

4.4 To clean/replace diaphragm assembly

4.4.1 Back out the adjusting screw until the spring is no longer compressed.

4.4.2 Remove the four bonnet screws and separate the bonnet from the body of the regulator. Remove the spring guide and spring.

4.4.3 Remove the diaphragm assembly, clean or replace it as necessary and reassemble in reverse order. After placing the diaphragm assembly on the body, push down the assembly to make sure that the pintle is seated properly and strokes smoothly.

4.5 Repair kits/replacement parts

4.5.1 Repair kits include all parts marked with an asterisk (*). See diagrams on page 1.

4.5.2 When ordering repair kits or replacement filters, order as:

REPAIR KITS PRG 350

Includes: Pintle Assembly, Housing Seal O-Ring, Diaphragm Assembly, Filter Seal O-Ring (2)

Model Porting Description Part Number

PRG 354 PRG 352 1/4” NPT 1/2” NPT Relieving Relieving 449-871-068 449-871-070 4.5.3 Other replacement parts are available. Please consult Omega Engineering, Inc. for part numbers and availability.

M-4808/0 916 REV 09/ 14/17 PRG 350 Series Page 4

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of

13 months

from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal

one (1) year product warranty

to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of consequential, incidental or special damages.

CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR

WARRANTY

OMEGA: RETURNS, please have the following information available BEFORE contacting was PURCHASED, 2. warranty, and 3. Repair instructions and/or specific problems relative to the product.

FOR

NON-WARRANTY

REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.

OMEGA is a registered trademark of OMEGA ENGINEERING, INC.

© Copyright 2016 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course!

Shop online at omega.com

SM

TEMPERATURE

Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers

PRESSURE, STRAIN AND FORCE

Transducers & Strain Gages Load Cells & Pressure Gages Displacement Transducers Instrumentation & Accessories

FLOW/LEVEL

Rotameters, Gas Mass Flowmeters & Flow Computers Air Velocity Indicators Turbine/Paddlewheel Systems Totalizers & Batch Controllers

pH/CONDUCTIVITY

pH Electrodes, Testers & Accessories Benchtop/Laboratory Meters Controllers, Calibrators, Simulators & Pumps Industrial pH & Conductivity Equipment

DATA ACQUISITION

Communications-Based Acquisition Systems Data Logging Systems Wireless Sensors, Transmitters, & Receivers Signal Conditioners Data Acquisition Software

HEATERS

Heating Cable Cartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory Heaters

ENVIRONMENTAL MONITORING AND CONTROL

Metering & Control Instrumentation Refractometers Pumps & Tubing Air, Soil & Water Monitors Industrial Water & Wastewater Treatment pH, Conductivity & Dissolved Oxygen Instruments M 4808 / 09 16

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement