Bradford White RG130T6N Atmospheric Vent Gas Quick Service Guide

Add to My manuals
1 Pages

advertisement

Bradford White RG130T6N Atmospheric Vent Gas Quick Service Guide | Manualzz

Error Code

Atmospheric Vent Water Heaters - ICON

Definition Service Action Possible Parts Needed

No LED

One flash & three second pause

LED Strobe (two quick flashes)

& three second pause

LED on continuously

Two flashes & three second pause

Three flashes & three second pause

Four flashes & three second pause

Five flashes & three second pause

Six flashes & three second pause

No pilot light / Heater not in operation

Knob in pilot position or thermostat satisfied

Thermostat calling for heat

Control knob turned to the off position

Weak pilot signal detected

Gas valve has not seen temp rise in proper amount of time

High tank temperature

Thermostat sensor fault Check temp probe ohms

Check water temperature

Water leak detected by the accessory module Refer to troubleshooting for the

(if installed) accessory module

Seven flashes & three second pause Gas valve fault

Eight flashes & three second pause Pilot remains lit while the control knob is in off position

Follow lighting instructions on the water heater

None

None

Wait for LED to go off before relighting

Verify pilot is lit

Check thermopile voltage output

Check wire connections at gas valve

Check temp probe ohms

Verify water is not flowing

Check temp probe ohms

Check water temperature

Reset gas valve; if problem persists replace gas valve

Check gas pressure

Replace gas valve

1) None

1) None

1) None

1) None

1) Pilot assembly

2) Gas valve

1) Gas valve cover w/ temp probe

1) Gas valve cover w/ temp probe

1) Gas valve cover w/ temp probe

1) Refer to troubleshooting for the

accessory module

1) Gas valve

1) Gas valve

NOTE: Check all wire connections

Check gas inlet and manifold gas pressure

Check for grounding connections

Technical Support

800-334-3393 www.bradfordwhite.com