BFT Rigel 6 Control Panel Instruction manual
Below you will find brief information for universal control unit RIGEL 6. This device is designed for controlling one or two motors, offering a wide range of options for creating automated gates or doors. It includes features for safety, security, and customization. You can set the opening and closing speed, delay times, and even create custom combinations of the motor. You can also program the control unit to work with different types of sensors, such as photocells and safety edges.
Advertisement
Advertisement
CENTRALINA UNIVERSALE pER IL CONTROLLO DI UNO O DUE MOTORI
UNIVERSAL CONTROL UNIT FOR ONE OR TWO MOTORS
CENTRALE UNIVERSELLE pERMETTANT DE CONTRôLER UN OU DEUx MOTEUR
UNIVERSAL-STEUERgERäT ZUR STEUERUNg VON EINEM ODER ZWEI MOTOREN
CENTRALITA UNIVERSAL pARA CONTROLAR UNO O DOS MOTORES
UNIVERSELE BESTURINgSEENHEID VOOR DE BESTURINg VAN 1 OF 2 MOTOREN
Attenzione!
Leggere attentamente le “Avvertenze” all’interno! Caution! Read “Warnings” inside carefully! Attention!
Veuillez lire attentivement les Avertissements qui se trouvent à l’intérieur! Achtung!
Bitte lesen Sie aufmerksam die „Hinweise“ im Inneren! ¡Atención¡ Leer atentamente las “Advertencias” en el interior! Let op! Lees de “Waarschuwingen” aan de binnenkant zorgvuldig!
AVVERTENZE PER L’UTILIZZATORE ( I )
Leggere e seguire attentamente le Avvertenze e le Istruzioni che accompagnano il prodotto poiché un uso improprio può causare danni a persone, animali o cose. Conservare le istruzioni per consultazioni future e trasmetterle ad eventuali subentranti nell’uso dell’impianto.
Questo prodotto dovrà essere destinato solo all’uso per il quale è stato espressamente installato. Ogni altro uso è da considerarsi improprio e quindi pericoloso. Il costruttore non può essere considerato responsabile per eventuali danni causati da usi impropri, erronei e irragionevoli.
SICUREZZA GENERALE
Nel ringraziarVi per la preferenza accordata a questo prestazioni necessarie al Vostro uso.
Questo prodotto risponde alle norme riconosciute della tecnica e della disposizioni relative alla sicurezza se correttamente installato da personale qualificato ed esperto (installatore professionale).
L’automazione, se installata ed utilizzata correttamente, soddisfa gli standard di sicurezza nell’uso.
Tuttavia è opportuno osservare alcune regole di comportamento per evitare inconvenienti accidentali:
- Tenere bambini, persone e cose fuori dal raggio d’azione dell’automazione, in particolare durante il movimento.
- Non permettere a bambini di giocare o sostare nel raggio di azione dell’automazione.
- L’apparecchio può essere utilizzato da bambini di età non inferiore a 8 anni e da persone con ridotte capacità fisiche, sensoriali o mentali, o prive di esperienza o della necessaria conoscenza, purché sotto sorveglianza oppure dopo che le stesse abbiano ricevuto istruzioni relative all’uso sicuro dell’apparecchio e alla comprensione dei pericoli ad esso inerenti. I bambini non devono giocare con l’apparecchio. La pulizia e la manutenzione destinata ad essere effettuata dall’utilizzatore non deve essere effettuata da bambini senza sorveglianza.
- I bambini devono essere sorvegliati per sincerarsi che non giochino con l’apparecchio. Non permettere ai bambini di giocare con i controlli fissi. Tenere i telecomandi lontani dai bambini.
- Evitare di operare in prossimità delle cerniere o organi meccanici in movimento.
- Non contrastare il movimento dell’anta e non tentare di aprire manualmente la porta se non è stato sbloccato l’attuatore con l’apposito sblocco.
- Non entrare nel raggio di azione della porta o cancello motorizzati durante il loro movimento.
- Non lasciare radiocomandi o altri dispositivi di comando alla portata dei bambini onde evitare azionamenti involontari.
- L’attivazione dello sblocco manuale potrebbe causare movimenti incontrollati della porta se in presenza di guasti meccanici o di condizioni di squilibrio.
- In caso di apritapparelle: sorvegliare la tapparella in movimento e tenere lontano le persone finché non è completamente chiusa. Porre cura quando si aziona lo sblocco se presente, poiché una tapparella aperta potrebbe cadere rapidamente in presenza di usura o rotture.
- La rottura o l’usura di organi meccanici della porta
(parte guidata), quali ad esempio cavi, molle, sup-
D811767_08
2 - RIgEL 6 controllare periodicamente l’impianto da personale qualificato ed esperto (installatore professionale) secondo quanto indicato dall’installatore o dal costruttore della porta.
- Per ogni operazione di pulizia esterna, togliere l’alimentazione di rete.
- Tenere pulite le ottiche delle fotocellule ed i dispositivi di segnalazione luminosa. Controllare che rami ed arbusti non disturbino i dispositivi di sicurezza.
- Non utilizzare l’automatismo se necessita di interventi di riparazione. In caso di guasto o di malfunzionamento dell’automazione, togliere l’alimentazione di rete sull’automazione, astenersi da qualsiasi tentativo di riparazione o intervento diretto e rivolgersi solo a personale qualificato ed esperto (installatore professionale) per la necessaria riparazione o manutenzione. Per consentire l’accesso, attivare lo sblocco di emergenza (se presente).
- Per qualsiasi intervento diretto sull’automazione o sull’impianto non previsto dal presente manuale, avvalersi di personale qualificato ed esperto (installatore professionale).
- Con frequenza almeno annuale far verificare l’integrità e il corretto funzionamento dell’automazione da personale qualificato ed esperto (installatore professionale), in particolare di tutti i dispositivi di sicurezza.
- Gli interventi d’installazione, manutenzione e riparazione devono essere documentati e la relativa documentazione tenuta a disposizione dell’utilizzatore.
- Il mancato rispetto di quanto sopra può creare situazioni di pericolo.
DEMOLIZIONE
L’eliminazione dei materiali va fatta rispettando le norme vigenti. Non gettate il vostro apparecchio scartato, le pile o le batterie usate nei rifiuti domestici. Avete la responsabilità di restituire tutti i vostri rifiuti da apparecchiature elettriche o elettroniche lasciandoli in un punto di raccolta dedicato al loro riciclo.
Tutto quello che non è espressamente previsto nel manuale d’uso, non è permesso. ll buon funzionamento dell’operatore è garantito solo se vengono rispettate le prescrizioni riportate in questo manuale. La Ditta non risponde dei danni causati dall’inosservanza delle indicazioni riportate in questo manuale.
Lasciando inalterate le caratteristiche essenziali del prodotto, la Ditta si riserva di apportare in qualunque momento le modifiche che essa ritiene convenienti per migliorare tecnicamente, costruttivamente e commercialmente il prodotto, senza impegnarsi ad aggiornare la presente pubblicazione.
USER WARNINGS (GB) refully read and comply with the Warnings and
Instructions that come with the product as improper use can cause injury to people and animals and damage to property. Keep the instructions for future reference and hand them on to any new users.
This product is meant to be used only for the purpose for which it was explicitly installed.
Any other use constitutes improper use and, consequently, is hazardous. The manufacturer cannot be held liable for any damage as a result of improper, incorrect or unreasonable use.
GENERAL SAFETY
Thank you for choosing this product. The Firm is rating needs.
This product meets recognized technical standards and complies with safety provisions when installed correctly by qualified, expert personnel (professional installer).
If installed and used correctly, the automated system will meet operating safety standards. Nonetheless, it is advisable to observe certain rules of behaviour so that accidental problems can be avoided:
- Keep adults, children and property out of range of the automated system, especially while it is moving.
- Do not allow children to play or stand within range of the automated system.
- The unit can be used by children over 8 years old and by people with reduced physical, sensory or mental capabilities or with no experience or necessary knowledge on condition they are supervised or trained about the safe use of the equipment and understand the risks involved. Children must not play with the unit. Cleaning and maintenance must not be performed by unsupervised children.
- Children must be supervised to ensure they do not play with the device. Do not allow children to play with the fixed controls. Keep remote controls out of reach of children.
- Do not work near hinges or moving mechanical parts.
- Do not hinder the leaf’s movement and do not attempt to open the door manually unless the actuator has been released with the relevant release knob.
- Keep out of range of the motorized door or gate while they are moving.
- Keep remote controls or other control devices out of reach of children in order to avoid the automated system being operated inadvertently.
- The manual release’s activation could result in uncontrolled door movements if there are mechanical faults or loss of balance.
- When using roller shutter openers: keep an eye on the roller shutter while it is moving and keep people away until it has closed completely. Exercise care when activating the release, if such a device is fitted, as an open shutter could drop quickly in the event of wear or breakage.
- The breakage or wear of any mechanical parts of the door (operated part), such as cables, springs, supports, hinges, guides…, may generate a hazard.
Have the system checked by qualified, expert personnel (professional installer) at regular intervals according to the instructions issued by the installer or manufacturer of the door.
- When cleaning the outside, always cut off mains power.
- Keep the photocells’ optics and illuminating indicator devices clean. Check that no branches or shrubs interfere with the safety devices.
- Do not use the automated system if it is in need of repair. In the event the automated system breaks down or malfunctions, cut off mains power to the system; do not attempt to repair or perform any other work to rectify the fault yourself and instead installer) to perform the necessary repairs or mainrelease (where fitted).
- If any part of the automated system requires direct work of any kind that is not contemplated herein, employ the services of qualified, expert personnel
(professional installer).
- At least once a year, have the automated system, and especially all safety devices, checked by qualified, expert personnel (professional installer) to make sure that it is undamaged and working properly.
- A record must be made of any installation, maintenance and repair work and the relevant documentation kept and made available to the user on request.
- Failure to comply with the above may result in hazardous situations.
SCRAPPING
Materials must be disposed of in accordance away your discarded equipment or used batsible for taking all your waste electrical and centre.
Anything that is not explicitly provided for in the operation can only be guaranteed if the instrucshall not be answerable for damage caused by herein.
While we will not alter the product’s essential to make those changes deemed opportune to improve the product from a technical, design or to update this publication accordingly.
AVERTISSEMENTS POUR L’UTILISATEUR (F)
ATTENTION ! Instructions de sécurité importantes. Veuillez lire et suivre attentivement tous les avertissements et toutes les instructions fournis avec le produit sachant qu’un usage incorrect peut provoquer des préjudices aux personnes, aux animaux ou aux biens. Veuillez conserver les instructions pour d’ultérieures consultations et pour les transmettre aux propriétaires futurs
éventuels.
Cet appareil ne peut être destiné qu’à l’usage pour lequel il a été expressément installé. Tout autre usage sera considéré comme impropre et donc dangereux. Le fabricant ne sera en aucun cas considéré comme responsable des préjudices dus à un usage impropre, erroné ou déraisonné.
SECURITE GÉNÉRALE
Nous vous remercions d’avoir choisi ce produit performances attendues.
Ce produit, correctement installé par du personnel qualifié et expérimenté (monteur professionnel) est conforme aux normes reconnues de la technique et des prescriptions de sécurité.
Si l’automatisation est montée et utilisée correctement, elle garantit la sécurité d’utilisation prescrite.
Il est cependant nécessaire de respecter certaines règles de comportement pour éviter tout inconvé-
- Tenir les enfants, les personnes et les objets à l’écart
D811767_08
Any other use constitutes improper use and, consequently, is hazardous. The manufacturer cannot be held liable for any damage as a result of improper, incorrect or unreasonable use.
GENERAL SAFETY
Thank you for choosing this product. The Firm is rating needs.
This product meets recognized technical standards and complies with safety provisions when installed correctly by qualified, expert personnel (professional installer).
If installed and used correctly, the automated system will meet operating safety standards. Nonetheless, it is advisable to observe certain rules of behaviour so that accidental problems can be avoided:
- Keep adults, children and property out of range of the automated system, especially while it is moving.
- Do not allow children to play or stand within range of the automated system.
- The unit can be used by children over 8 years old and by people with reduced physical, sensory or mental capabilities or with no experience or necessary knowledge on condition they are supervised or trained about the safe use of the equipment and understand the risks involved. Children must not play with the unit. Cleaning and maintenance must not be performed by unsupervised children.
- Children must be supervised to ensure they do not play with the device. Do not allow children to play with the fixed controls. Keep remote controls out of reach of children.
- Do not work near hinges or moving mechanical parts.
- Do not hinder the leaf’s movement and do not attempt to open the door manually unless the actuator has been released with the relevant release knob.
- Keep out of range of the motorized door or gate while they are moving.
- Keep remote controls or other control devices out of reach of children in order to avoid the automated system being operated inadvertently.
- The manual release’s activation could result in uncontrolled door movements if there are mechanical faults or loss of balance.
- When using roller shutter openers: keep an eye on the roller shutter while it is moving and keep people away until it has closed completely. Exercise care when activating the release, if such a device is fitted, as an open shutter could drop quickly in the event of wear or breakage.
- The breakage or wear of any mechanical parts of the door (operated part), such as cables, springs, supports, hinges, guides…, may generate a hazard.
Have the system checked by qualified, expert personnel (professional installer) at regular intervals according to the instructions issued by the installer or manufacturer of the door.
- When cleaning the outside, always cut off mains power.
- Keep the photocells’ optics and illuminating indicator devices clean. Check that no branches or shrubs interfere with the safety devices.
- Do not use the automated system if it is in need of repair. In the event the automated system breaks down or malfunctions, cut off mains power to the system; do not attempt to repair or perform any other work to rectify the fault yourself and instead installer) to perform the necessary repairs or mainrelease (where fitted).
- If any part of the automated system requires direct work of any kind that is not contemplated herein, employ the services of qualified, expert personnel
(professional installer).
- At least once a year, have the automated system, and especially all safety devices, checked by qualified, expert personnel (professional installer) to make sure that it is undamaged and working properly.
- A record must be made of any installation, maintenance and repair work and the relevant documentation kept and made available to the user on request.
- Failure to comply with the above may result in hazardous situations.
SCRAPPING
Materials must be disposed of in accordance with the regulations in force. Do not throw away your discarded equipment or used batteries with household waste. You are responsible for taking all your waste electrical and centre.
user guide is not allowed. The operator’s proper operation can only be guaranteed if the instructions given herein are complied with. The Firm shall not be answerable for damage caused by failure to comply with the instructions featured herein.
While we will not alter the product’s essential features, the Firm reserves the right, at any time, to make those changes deemed opportune to improve the product from a technical, design or commercial point of view, and will not be required to update this publication accordingly.
D811767_08
RIgEL 6 - 3
AVVERTENZE PER L’INSTALLATORE
ATTENZIONE! Importanti istruzioni di sicurezza. Leggere e seguire attentamente tutte le avvertenze e le istruzioni che accompagnano il prodotto poiché un’installazione errata può causare danni a persone, animali o cose.
Le avvertenze e le istruzioni forniscono importanti indicazioni riguardanti la sicurezza, l’installazione, l’uso e la manutenzione. Conservare le istruzioni per allegarle al fascicolo tecnico e per consultazioni future.
SICUREZZA GENERALE
Questo prodotto è stato progettato e costruito esclusivamente per l’utilizzo indicato in questa documentazione. Usi diversi da quanto indicato potrebbero essere causa di danni al prodotto e di pericolo.
-Gli elementi costruttivi della macchina e l’installazione devono essere in accordo con le seguenti Direttive Europee, ove applicabili: 2014/30/CE, 2014/35/CE,
2006/42/CE, 2011/305/CE, 99/05/CE e loro modifiche successive. Per tutti i Paesi extra CEE, oltre alle norme nazionali vigenti, per un buon livello di sicurezza è opportuno rispettare anche le norme citate.
-La Ditta costruttrice di questo prodotto (di seguito “Ditta”) declina qualsiasi responsabilità derivante da un uso improprio o diverso da quello per cui è destinato e indicato nella presente documentazione nonché dall’inosservanza della Buona Tecnica nella costruzione delle chiusure (porte, cancelli, ecc.) e dalle deformazioni che potrebbero verificarsi durante l’uso.
-L’installazione deve essere eseguita da personale qualificato (installatore professionale, secondo EN12635), nell’osservanza della Buona Tecnica e delle norme vigenti.
-Prima di installare il prodotto apportare tutte le modifiche strutturali relative alle realizzazione dei franchi di sicurezza a alla protezione o segregazione di tutte le zone di schiacciamento, cesoiamento, convogliamento e di pericolo in genere, secondo quanto previsto dalle norme EN 12604 ed 12453 o eventuali norme locali di installazione. Verificare che la struttura esistente abbia i necessari requisiti di robustezza e stabilità.
-Prima di iniziare l’installazione verificare l’integrità del prodotto.
-La Ditta non è responsabile della inosservanza della Buona Tecnica nella costruzione e manutenzione degli infissi da motorizzare, nonché delle deformazioni che dovessero intervenire nell’utilizzo.
-Verificare che l’intervallo di temperatura dichiarato sia compatibile con il luogo destinato all’installazione dell’automazione.
-Non installare questo prodotto in atmosfera esplosiva: la presenza di gas o fumi infiammabili costituisce un grave pericolo per la sicurezza.
- Togliere l’alimentazione elettrica, prima di qualsiasi intervento sull’impianto.
Scollegare anche eventuali batterie tampone se presenti.
-Prima di collegare l’alimentazione elettrica, accertarsi che i dati di targa corrispondano ai quelli della rete di distribuzione elettrica e che a monte dell’impianto elettrico vi siano un interruttore differenziale e una protezione da sovracorrente adeguati. Prevedere sulla rete di alimentazione dell’automazione, un interruttore o un magnetotermico onnipolare che consenta la disconnessione completa nelle condizioni della categoria di sovratensione III.
-Verificare che a monte della rete di alimentazione, vi sia un interruttore differenziale con soglia non superiore a 0.03A e a quanto previsto dalle norme vigenti.
-Verificare che l’impianto di terra sia realizzato correttamente: collegare a terra tutte le parti metalliche della chiusura (porte, cancelli, ecc.) e tutti i componenti dell’impianto provvisti di morsetto di terra.
-L’installazione deve essere fatta utilizzando dispositivi di sicurezza e di comandi conformi alla EN 12978 e EN12453.
-Le forze di impatto possono essere ridotte mediante l’utilizzo di bordi deformabili.
-Nel caso in cui le forze di impatto superino i valori previsti dalle norme, applicare dispositivi elettrosensibili o sensibili alla pressione.
-Applicare tutti i dispositivi di sicurezza (fotocellule, coste sensibili, ecc.) necessari a proteggere l’area da pericoli di impatto, schiacciamento, convogliamento, cesoiamento. Tenere in considerazione le normative e le direttive in vigore, i criteri della Buona Tecnica, l’utilizzo, l’ambiente di installazione, la logica di funzionamento del sistema e le forze sviluppate dall’automazione.
-Applicare i segnali previsti dalle normative vigenti per individuare le zone pericolose (i rischi residui). Ogni installazione deve essere identificata in modo visibile secondo quanto prescritto dalla EN13241-1.
- Successivamente al completamento dell’installazione, applicare una targa identificativa della porta/cancello
-Questo prodotto non può essere installato su ante che incorporano delle porte
(a meno che il motore sia azionabile esclusivamente a porta chiusa).
-Se l’automazione è installata ad una altezza inferiore a 2,5 m o se è accessibile,
è necessario garantire un adeguato grado di protezione delle parti elettriche e meccaniche.
-Solo per automazioni per serrande
1) Le parti in movimento del motore devono essere installate ad una altezza superiore a 2,5m al di sopra del pavimento o al di sopra di un altro livello che possa consentirne l’accesso.
2) Il motoriduttore deve essere installato in uno spazio segregato e provvisto di protezione in modo che sia accessibile solo con uso di utensili.
-Installare qualsiasi comando fisso in posizione tale da non causare pericoli e lontano da parti mobili. In particolare i comandi a uomo presente devono essere posizionati in vista diretta della parte guidata, e, a meno che non siano a chiave, devono essere installati a una altezza minima di 1,5 m e in modo tale da non essere accessibili al pubblico.
-Applicare almeno un dispositivo di segnalazione luminosa (lampeggiante) in posizione visibile, fissare inoltre alla struttura un cartello di Attenzione.
-Fissare in modo permanente una etichetta relativa al funzionamento dello sblocco manuale dell’automazione e apporla vicino all’organo di manovra.
-Assicurarsi che durante la manovra siano evitati o protetti i rischi meccanici ed in particolare l’impatto, lo schiacciamento, il convogliamento, il cesoiamento tra parte guidata e parti circostanti.
-Dopo aver eseguito l’installazione, assicurarsi che il settaggio dell’automazione motore sia correttamente impostato e che i sistemi di protezione e di sblocco funzionino correttamente.
-Usare esclusivamente parti originali per qualsiasi manutenzione o riparazione.
La Ditta declina ogni responsabilità ai fini della sicurezza e del buon funzionamento dell’automazione se vengono impiegati componenti di altri produttori.
-Non eseguire alcuna modifica ai componenti dell’automazione se non espressamente autorizzata dalla Ditta.
-Istruire l’utilizzatore dell’impianto per quanto riguarda gli eventuali rischi residui, i sistemi di comando applicati e l’esecuzione della manovra apertura manuale in caso di emergenza: consegnare il manuale d’uso all’utilizzatore finale.
-Smaltire i materiali di imballo (plastica, cartone, polistirolo, ecc.) secondo quanto previsto dalle norme vigenti. Non lasciare buste di nylon e polistirolo alla portata dei bambini.
COLLEGAMENTI
ATTENZIONE! Per il collegamento alla rete utilizzare: cavo multipolare di sezione minima 5x1,5mm 2 o 4x1,5mm 2 per alimentazioni trifase oppure 3x1,5mm 2 per alimentazioni monofase (a titolo di esempio, il cavo può essere del tipo H05RN-F con sezione 4x1.5mm
2 ). Per il collegamento degli ausiliari utilizzare conduttori con sezione minima di 0,5 mm 2 .
-Utilizzare esclusivamente pulsanti con portata non inferiore a 10A-250V.
-I conduttori devono essere vincolati da un fissaggio supplementare in prossimità dei morsetti (per esempio mediante fascette) al fine di tenere nettamente separate le parti in tensione dalle parti in bassissima tensione di sicurezza.
-Il cavo di alimentazione, durante l’installazione, deve essere sguainato in modo da permettere il collegamento del conduttore di terra all’appropriato morsetto lasciando però i conduttori attivi il più corti possibile. Il conduttore di terra deve essere l’ultimo a tendersi in caso di allentamento del dispositivo di fissaggio del cavo.
ATTENZIONE! i conduttori a bassissima tensione di sicurezza devono essere fisicamente separati dai conduttori a bassa tensione.
L’accessibilità alle parti in tensione deve essere possibile esclusivamente per il personale qualificato (installatore professionale)
VERIFICA DELL’AUTOMAZIONE E MANUTENZIONE
Prima di rendere definitivamente operativa l’automazione, e durante gli interventi di manutenzione, controllare scrupolosamente quanto segue:
-Verificare che tutti i componenti siano fissati saldamente;
-Verificare l’operazione di avvio e fermata nel caso di comando manuale.
-Verificare la logica di funzionamento normale o personalizzata.
-Solo per cancelli scorrevoli: verificare il corretto ingranamento cremagliera pignone con un gioco di 2 mm lungo tutta la cremagliera; tenere la rotaia di scorrimento sempre pulita e libera da detriti.
-Solo per cancelli e porte scorrevoli: verificare che il binario di scorrimento del cancello sia lineare, orizzontale e le ruote siano idonee a sopportare il peso del cancello.
-Solo per cancelli scorrevoli sospesi (Cantilever): verificare che non ci sia abbassamento o oscillazione durante la manovra.
-Solo per cancelli a battente: verificare che l’asse di rotazione delle ante sia perfettamente verticale.
- Solo per barriere: prima di aprire la portina la molla deve essere scarica
(asta verticale).
-Controllare il corretto funzionamento di tutti i dispositivi di sicurezza (fotocellule, coste sensibili, ecc) e la corretta regolazione della sicurezza antischiacciamento verificando che il valore della forza d’impatto misurato nei punti previsti dalla norma EN 12445, sia inferiore a quanto indicato nella norma EN 12453.
-Le forze di impatto possono essere ridotte mediante l’utilizzo di bordi deformabili.
-Verificare la funzionalità della manovra di emergenza ove presente.
-Verificare l’operazione di apertura e chiusura con i dispositivi di comando applicati.
-Verificare l’integrità delle connessioni elettriche e dei cablaggi, in particolare lo stato delle guaine isolanti e dei pressa cavi.
-Durante la manutenzione eseguire la pulizia delle ottiche delle fotocellule.
-Per il periodo di fuori servizio dell’automazione, attivare lo sblocco di emergenza
(vedi paragrafo “MANOVRA DI EMERGENZA”) in modo da rendere folle la parte guidata e permettere così l’ apertura e la chiusura manuale del cancello.
-Se il cavo di alimentazione è danneggiato, esso deve essere sostituito dal costruttore o dal suo servizio di assistenza tecnica o comunque da una persona con qualifica similare, in modo da prevenire ogni rischio.
-Se si si installano dispositivi di tipo “D” (come definiti dalla EN12453), collegati in modalità non verificata, prescrivere una manutenzione obbligatoria con frequenza almeno semestrale.
- La manutenzione come sopra descritta deve essere ripetuta con frequenza almeno annuale o ad intervalli di tempo minori qualora le caratteristiche del sito o dell’installazione lo richiedessero.
ATTENZIONE!
Ricordarsi che la motorizzazione è una facilitazione dell’uso del cancello/porta e non risolve problemi a difetti e deficienze di installazione o di mancata manutenzione.
DEMOLIZIONE
L’eliminazione dei materiali va fatta rispettando le norme vigenti. Non gettate il vostro apparecchio scartato, le pile o le batterie usate nei rifiuti domestici. Avete la responsabilità di restituire tutti i vostri rifiuti da apparecchiature elettriche o elettroniche lasciandoli in un punto di raccolta dedicato al loro riciclo.
SMANTELLAMENTO
Nel caso l’automazione venga smontata per essere poi rimontata in altro sito bisogna:
-Togliere l’alimentazione e scollegare tutto l’impianto elettrico.
-Togliere l’attuatore dalla base di fissaggio.
-Smontare tutti i componenti dell’installazione.
-Nel caso alcuni componenti non possano essere rimossi o risultino danneggiati, provvedere alla loro sostituzione.
LE DICHIARAZIONI DI CONFORMITÀ SONO CONSULTABILI NEL SITO WEB: http://www.bft-automation.com/CE
LE ISTRUZIONI DI MONTAGGIO ED USO SONO CONSULTABILI NELLA SEZIONE
DOWNLOAD.
Tutto quello che non è espressamente previsto nel manuale d’installazione, non è permesso. ll buon funzionamento dell’operatore è garantito solo se vengono rispettati i dati riportati. La ditta non risponde dei danni causati dall’inosservanza delle indicazioni riportate in questo manuale.
Lasciando inalterate le caratteristiche essenziali del prodotto, la Ditta si riserva di apportare in qualunque momento le modifiche che essa ritiene convenienti per migliorare tecnicamente, costruttivamente e commercialmente il prodotto, senza impegnarsi ad aggiornare la presente pubblicazione.
D811766_16
INSTALLER WARNINGS
WARNING! Important safety instructions. Carefully read and comply with all the warnings and instructions that come with the product as incorrect installation can cause injury to people and animals and damage to property.
The warnings and instructions give important information regarding safety, installation, use and maintenance. Keep hold of instructions so that you can attach them to the technical file and keep them handy for future reference.
GENERAL SAFETY
This product has been designed and built solely for the purpose indicated herein.
Uses other than those indicated herein might cause damage to the product and create a hazard.
- The units making up the machine and its installation must meet the requirements of the following European Directives, where applicable: 2014/30/EC, 2014/35/
EC, 2006/42/EC, 2011/305/EC, 99/05/EC and later amendments. For all countries outside the EEC, it is advisable to comply with the standards mentioned, in addition to any national standards in force, to achieve a good level of safety.
- The Manufacturer of this product (hereinafter referred to as the “Firm”) disclaims all responsibility resulting from improper use or any use other than that for which the product has been designed, as indicated herein, as well as for failure to apply Good Practice in the construction of entry systems (doors, gates, etc.) and for deformation that could occur during use.
- Installation must be carried out by qualified personnel (professional installer, according to EN 12635), in compliance with Good Practice and current code.
- Before installing the product, make all structural changes required to produce safety gaps and to provide protection from or isolate all crushing, shearing and dragging hazard areas and danger zones in general in accordance with the provisions of standards EN 12604 and 12453 or any local installation standards.
Check that the existing structure meets the necessary strength and stability requirements.
- Before commencing installation, check the product for damage.
- The Firm is not responsible for failure to apply Good Practice in the construction and maintenance of the doors, gates, etc. to be motorized, or for deformation that might occur during use.
- Make sure the stated temperature range is compatible with the site in which the automated system is due to be installed.
- Do not install this product in an explosive atmosphere: the presence of flammable fumes or gas constitutes a serious safety hazard.
- Disconnect the electricity supply before performing any work on the system.
Also disconnect buffer batteries, if any are connected.
- Before connecting the power supply, make sure the product’s ratings match the mains ratings and that a suitable residual current circuit breaker and overcurrent protection device have been installed upline from the electrical system. Have the automated system’s mains power supply fitted with a switch or omnipolar thermal-magnetic circuit breaker with a contact separation that provide full disconnection under overvoltage category III conditions.
- Make sure that upline from the mains power supply there is a residual current circuit breaker that trips at no more than 0.03A as well as any other equipment required by code.
- Make sure the earth system has been installed correctly: earth all the metal parts belonging to the entry system (doors, gates, etc.) and all parts of the system featuring an earth terminal.
- Installation must be carried out using safety devices and controls that meet standards EN 12978 and EN 12453.
- Impact forces can be reduced by using deformable edges.
- In the event impact forces exceed the values laid down by the relevant standards, apply electro-sensitive or pressure-sensitive devices.
- Apply all safety devices (photocells, safety edges, etc.) required to keep the area free of impact, crushing, dragging and shearing hazards. Bear in mind the standards and directives in force, Good Practice criteria, intended use, the installation environment, the operating logic of the system and forces generated by the automated system.
- Apply all signs required by current code to identify hazardous areas (residual risks). All installations must be visibly identified in compliance with the provisions
- of standard EN 13241-1.
Once installation is complete, apply a nameplate featuring the door/gate’s data.
- This product cannot be installed on leaves incorporating doors (unless the motor can be activated only when the door is closed).
- If the automated system is installed at a height of less than 2.5 m or is accessible, the electrical and mechanical parts must be suitably protected.
- For roller shutter automation only
1) The motor’s moving parts must be installed at a height greater than 2.5 m above the floor or other surface from which they may be reached.
2) The gearmotor must be installed in a segregated and suitably protected space so that it cannot be reached without the aid of tools.
- Install any fixed controls in a position where they will not cause a hazard, away from moving parts. More specifically, hold-to-run controls must be positioned within direct sight of the part being controlled and, unless they are key operated, must be installed at a height of at least 1.5 m and in a place where they cannot be reached by the public.
- Apply at least one warning light (flashing light) in a visible position, and also attach a Warning sign to the structure.
- Attach a label near the operating device, in a permanent fashion, with information on how to operate the automated system’s manual release.
- Make sure that, during operation, mechanical risks are avoided or relevant protective measures taken and, more specifically, that nothing can be banged, crushed, caught or cut between the part being operated and surrounding parts.
- Once installation is complete, make sure the motor automation settings are correct and that the safety and release systems are working properly.
- Only use original spare parts for any maintenance or repair work. The Firm disclaims all responsibility for the correct operation and safety of the automated system if parts from other manufacturers are used.
- Do not make any modifications to the automated system’s components unless explicitly authorized by the Firm.
- Instruct the system’s user on what residual risks may be encountered, on the control systems that have been applied and on how to open the system manually in an emergency. give the user guide to the end user.
- Dispose of packaging materials (plastic, cardboard, polystyrene, etc.) in accordance with the provisions of the laws in force. Keep nylon bags and polystyrene out of reach of children.
WIRING
WARNING! For connection to the mains power supply, use: a multicore cable with a cross-sectional area of at least 5x1.5mm
2 or 4x1.5mm
2 when dealing with threephase power supplies or 3x1.5mm
2 for single-phase supplies (by way of example, type H05RN-F cable can be used with a cross-sectional area of 4x1.5mm
2 ). To connect auxiliary equipment, use wires with a cross-sectional area of at least 0.5 mm 2 .
- Only use pushbuttons with a capacity of 10A-250V or more.
- Wires must be secured with additional fastening near the terminals (for example, using cable clamps) in order to keep live parts well separated from safety extra low voltage parts.
- During installation, the power cable must be stripped to allow the earth wire to be connected to the relevant terminal, while leaving the live wires as short as possible. The earth wire must be the last to be pulled taut in the event the cable’s fastening device comes loose.
WARNING!
safety extra low voltage wires must be kept physically separate from low voltage wires.
Only qualified personnel (professional installer) should be allowed to access live parts.
CHECKING THE AUTOMATED SYSTEM AND MAINTENANCE
Before the automated system is finally put into operation, and during maintenance work, perform the following checks meticulously:
- Make sure all components are fastened securely.
- Check starting and stopping operations in the case of manual control.
- Check the logic for normal or personalized operation.
- For sliding gates only: check that the rack and pinion mesh correctly with 2 mm of play along the full length of the rack; keep the track the gate slides on clean and free of debris at all times.
- For sliding gates and doors only: make sure the gate’s running track is straight and horizontal and that the wheels are strong enough to take the weight of the gate.
- For cantilever sliding gates only: make sure there is no dipping or swinging during operation.
- For swing gates only: make sure the leaves’ axis of rotation is perfectly vertical.
-For barriers only: before opening the door, the spring must be decompressed
(vertical boom).
- Check that all safety devices (photocells, safety edges, etc.) are working properly and that the anti-crush safety device is set correctly, making sure that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.
- Impact forces can be reduced by using deformable edges.
- Make sure that the emergency operation works, where this feature is provided.
- Check opening and closing operations with the control devices applied.
- Check that electrical connections and cabling are intact, making extra sure that insulating sheaths and cable glands are undamaged.
- While performing maintenance, clean the photocells’ optics.
- When the automated system is out of service for any length of time, activate the emergency release (see “EMERGENCY OPERATION” section) so that the operated part is made idle, thus allowing the gate to be opened and closed manually.
- If the power cord is damaged, it must be replaced by the manufacturer or their technical assistance department or other such qualified person to avoid any risk .
- If “D” type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months
- The maintenance described above must be repeated at least once yearly or at shorter intervals where site or installation conditions make this necessary.
WARNING!
Remember that the drive is designed to make the gate/door easier to use and will not solve problems as a result of defective or poorly performed installation or lack of maintenance
SCRAPPING
Materials must be disposed of in accordance with the regulations in force. Do not throw away your discarded equipment or used batteries with household waste. You are responsible for taking all your waste electrical and electronic equipment to a suitable recycling centre.
DISMANTLING
If the automated system is being dismantled in order to be reassembled at another site, you are required to:
- Cut off the power and disconnect the whole electrical system.
- Remove the actuator from the base it is mounted on.
- Remove all the installation’s components.
- See to the replacement of any components that cannot be removed or happen to be damaged.
DECLARATIONS OF CONFORMITY CAN BE FOUND AT http://www.bftautomation.com/CE
INSTRUCTIONS FOR USE AND ASSEMBLY CAN BE FOUND IN THE DOWN-
LOAD SECTION.
Anything that is not explicitly provided for in the installation manual is not allowed. The operator’s proper operation can only be guaranteed if the information given is complied with. The Firm shall not be answerable for damage caused by failure to comply with the instructions featured herein.
While we will not alter the product’s essential features, the Firm reserves the right, at any time, to make those changes deemed opportune to improve the product from a technical, design or commercial point of view, and will not be required to update this publication accordingly.
D811766_16
RIgEL 6 - 9
INSTALLAZIONE VELOCE-QUICK INSTALLATION-INSTALLATION RAPIDE
SCHNELLINSTALLATION-INSTALACIÓN RÁPIDA - SNELLE INSTALLATIE
PREDISPOSIZIONE TUBI, TUBE ARRANGEMENT,
PRÉDISPOSITION DES TUYAUX, VORBEREITUNG DER LEITUNGEN,
DISPOSICIÓN DE TUBOS, VOORBEREIDING LEIDINGEN.
A 70 71 72 73 74 75 76 77 78 79 80 81 82
Collegamento Elettroserratura EBp 230V. Configurazione AUx= Lampeggiante
EBp solenoid lock connection 230V. AUx configuration = Flashing
Connexion serrure électrique EBp 230V. Configuration AUx= Clignotant
Anschluss Elektroschloss EBp 230 V. Konfigurierung AUx= Blinkleuchte
Conexión Cerradura eléctrica EBp 230V. Configuración AUx= parpadeante
Verbinding Elektrisch slot EBp 230V. Configuratie AUx= Knipperend
B
AUX 0
20 21
AUX 1
22 23
AUX 2
24 25 L N
GND
0,75
0,75
0,75
0,75
6.3 A/F 230V 10 A/F 110V
L N GND
10 11 12 14 15 16 20 21 22 23 24 25 26 27 28 29 50 51 52
NTC
Vedere specifica motore
See motor specifications
Consultez les caractéristiques du moteur
Siehe Motordaten
Véase especificaciones motor
Zie motorspecificatie
AUX 3 = 1
26 27
0,75
AUX 3 = 1
26 27 50 51
1
50 51
SAFE 1 = 0
70 72
C
1
2
TX1 RX1
1
2
3
4
5
Collegamento di 1 coppia di fotocellule non verificate, per fotocellule verificate vedere pagine seguenti.
Connection of 1 couple of untested photocells, for tested photocells see the following pages.
Connexion d’une paire de photocellules non vérifiées, pour les photocellules vérifiées consultez les pages suivantes.
Anschluss von einem paar nicht überprüfter
Fotozellen, für überprüfte Fotozelle siehe die folgenden Seiten.
Conexión de 1 par de fotocélulas no comprobadas, para fotocélulas comproabdas véanse las siguientes páginas.
Aansluiting van 1 paar niet-geverifieerde fotocellen. Raadpleeg de volgende pagina’s voor geverifieerde fotocellen.
Other voltages available on request
Autres tensions disponibles sur demande
Weitere Spannungen auf Anfrage erhältlich
Andere spanningen op aanvraag beschikbaar
Not supplied
Ne sont pas fournis
Nicht im lieferum
Niet meegeleverd
60 61 62 63 64 65 obbligatorio - compulsory obligatoire - obligatorisch obligatorio - verplicht
F1
315 m A/T 230V
630 m A/T 110V
6.3 A/F 230V 10 A/F 110V
L N
GND
Connettore scheda opzionale
Optional board connector
Connecteur carte facultative
Steckverbinder Zusatzkarte
Conector de la tarjeta opcional
Connector optionele kaart
60 61 62 63 64 65 40 41 42 43 44 45
Display + tasti programmazione
Display + programming keys
Afficheur + touches programmation
Display + programmierungstasten pantalla + botones programación
Display + programmeringstoetsen
70 71 72 73 74 75 76 77 78 79 80 81 82 8384 85
In chiusura inversione totale in apertura STOP.
Connecteur programmateur de poche
Steckverbinder palmtop-programmierer
Conector del programador de bolsillo
Connector programmeerbare palmtop
Batteria Litio 3V CR 1220
Lithium battery 3V CR 1220
Batterie Lithium 3V CR 1220
Lithiumbatterie 3 V CR 1220
Batería de Litio 3V CR 1220
Lithiumbatterij 3V CR 1220
10 11 12 14 15 16 20 21 22 23 24 25 26 27 28 29 50 51 52
NTC
Y #
40 41 42 43 44 45 70 71 72 73 74 75 76 77 78 79 80 81 82 8384 85
L N GND 10 11 12 14 15 16 20 21 22 23 24 25 26 27 28 29
220
230V
220
230V
50 51 52
Y #
L N
M1 M2
NTC
NTH5D223KA
ANT.
(MAX 10W)
AUX0+AUX1+AUX2=80W MAX
AUX
14 - RIgEL 6
x1
***
0--10--
MENU SEMPLIFICATO
*** Inserimento password.
Richiesta con logica Livello Protezione impostata a 1, 2, 3, 4
1501520 ok lang tipo n. mot.
Dir preset autoset
SWO/OK
SWO/OK
SWC/OK
SWC/OK m1.o
2 m2.o
2
2
2 close m2.c
1 m1.c
1
1
1 open int
EXT
AR sr ac sc ind idr elet
2
1
ITA fra deu eng esp
Idr : operatore idraulico
ELET: operatore elettromeccanico
INT : apertura verso l’interno
EXT : apertura verso l’esterno ar : funzionamento automatico, residenziale sr : funzionamento semi-aut., residenziale ac : funzionamento automatico, condominiale
Sc : funzionamento semi-automatico, condominiale
Ind : funzionamento a uomo presente
2
2
2
2
1
1
1
1
PRESET
PARAMETRI
Tempo di lavoro Motore 1
Tempo di lavoro Motore 2
Tempo sfasamento apertura
Tempo sfasamento chiusura
Tempo di rallentamento motore 1 idraulico elettromeccanico
Tempo di rallentamento motore 2 idraulico elettromeccanico
TCA
Forza apertura idraulico elettromeccanico
Forza chiusura
Forza rallentamento idraulico elettromeccanico idraulico elettromeccanico
LOGICHE
TCA
Movimento passo passo preallarme
Uomo presente
Blocca impulsi in apertura
Mantenimento blocco idraulico elettromeccanico
SAFE1
Livello protezione
DEFAULT AR SR AC SC ind
60.0
60.0
3
3
0
0
3
40
50
50
50
DEFAULT AR
0
0
0 0
1
1
0
0
0
0
0
1
0
0
0
4
0
99
50
99
50
20
99
50
3
0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
2
2
0
2
2
0
2
2
0
2
2
0
2
2
0
3
0
3
99
50
99
50
40
99
50
SR
0
0
0
0
0
1
0
4
0
3
0
3
99
50
99
50
30
99
50
AC
1
1
1
0
1
1
0
4
0
3
0
3
99
50
99
50
40
99
50
SC
1
0
0
1
4
0
0
0
1
3
0 ind
1
0
1
0
0
2
0
0
0
3
99
50
99
50
40
99
50 mem.telec
fine o o tasto nascosto rilascia tasto desiderato O 01
RIgEL 6 - 15
SIMPLIFIED MENU x1
***
0--10-1501520
*** Password entry.
Request with Protection Level logic set to 1, 2, 3, 4 ok language type n. mot.
Dir preset
2
1 int
EXT
AR sr ac sc ind
ITA fra deu eng esp hydr elec autoset
SWO/OK
SWO/OK
SWC/OK
SWC/OK m1.o
2 1 m2.o
2 1
2 close m2.c
1 m1.c
2 1 open hydr elec
: hydraulic operator
: electromechanical operator
INT
: inward opening
EXT : outward opening ar : automatic operation, residential sr
: semiautomatic operation, residential ac : automatic operation, commercial
Sc : semiautomatic operation, commercial
Ind : dead man operation
2
2
2
2
1
1
1
1
Scroll up
Scroll down
Exit Menù
PRESET
PARAMETER
Operation time motor 1
Operation time motor 2
Time lag opening
Time lag closing
Motor 1 slow-down time
Motor 2 slow-down time hydraulic electromechanical hydraulic electromechanical
TCA
Opening force
Closing force hydraulic electromechanical hydraulic electromechanical
Slow-down force hydraulic electromechanical
LOGIC
TCA
Step-by-step movement pre alarm
Hold-to-run
Impulse lock on opening hydraulic
Lock hold electromechanical
SAFE 1 protection level
DEFAULT
AR SR AC SC ind
60.0
60.0
3
3
0
0
40 20
99
50
50
99
50
50
99
50
50
DEFAULT
AR
0 1
0
0
0
0
0
0
1
0
1
0
0
0
0
4
0
20.0 20.0 20.0 20.0
20.0
20.0 20.0 20.0 20.0
20.0
0
3
2
2
0
3
2
2
0
3
0
3
2
2
0
3
0
3
2
2
0
3
0
3
0
3
2
2
0
3
40
99
50
99
50
99
50
SR
0
0
0
0
0
1
0
4
0
30
99
50
99
50
99
50
AC
1
1
1
0
1
1
0
4
0
40
99
50
99
50
99
50
SC
0
0
1
0
1
1
0
4
0
40
99
50
99
50
99
50
0
0
2 ind
0
1
0
0
0
1 mem.remotes
end
16 - RIgEL 6 o o hidden button release desidered button O 01
SIMPLIFIED MENU x1
0--10-150language type n. mot.
Dir preset
2
1 int
EXT
AR sr ac sc ind
ITA fra deu eng esp hydr elec autoset
SWO/OK
SWO/OK
SWC/OK
SWC/OK m1.o
2 1 m2.o
2 1
2 close m2.c
1 m1.c
2 1 open hydr elec
: hydraulic operator
: electromechanical operator
INT
: inward opening
EXT : outward opening ar : automatic operation, residential sr
: semiautomatic operation, residential ac : automatic operation, commercial
Sc : semiautomatic operation, commercial
Ind : dead man operation
2
2
2
2
1
1
1
1
1520 mem.remotes
end o o hidden button release desidered button O 01 ok
Scroll up
Scroll down
Exit Menù x1
***
0--10--
MENU SIMPLIFIÉ
1501520
*** Saisie du mot de passe.
Demande avec logique Niveau Protection configurée sur
1, 2, 3, 4 ok
lang int
EXT
AR sr ac sc ind
ITA fra deu eng esp hydr elec
2
1 type n. mot.
Dir preset autoset
SWO/OK
SWO/OK
SWC/OK
SWC/OK m1.o
2 m2.o
2
2
2 close m2.c
1 m1.c
1
1
1 open
Monter
Descendre
Confirmation / allumage afficheur
Sortir du menu hydr
ELEc:
INT
EXT ar ac
Sc
Ind
: Actionneur hydraulique
Actionneur électromécanique
: ouverture vers l’intérieur
: ouverture vers l’extérieur
: fonctionnement automatique, résidentiel sr : fonctionnement semi-automatique, résidentiel
: fonctionnement automatique, collectif
: fonctionnement semi-automatique, collectif
: fonctionnement à homme présent
2 1
PRESET
PARAMèTRES
Temps de travail moteur 1
Temps de travail moteur 2
Temps déphasage ouverture
Temps déphasage fermeture
Temps ralentissement moteur 1 hydraulique electromecanique
Temps ralentissement moteur 2 hydraulique electromecanique
TCA
Force ouverture
Force fermeture hydraulique electromecanique hydraulique electromecanique
Force ralentissement hydraulique electromecanique
LOGIQUES
TCA
Force ralentissement préalarme
Homme présent
Blocage des Impulsions d’ouverture hydraulique
Maintient du blocage electromecanique
SAFE 1
Niveau de protection
2 1
DEFAULT
AR SR AC SC ind
60.0
60.0
3
3
0
0
40 20
99
50
50
99
50
50
99
50
50
DEFAULT
AR
0 1
0
0
0
0
0
0
1
0
1
0
0
0
0
4
0
0
3
2
0
3
20.0 20.0 20.0 20.0
20.0
20.0 20.0 20.0 20.0
20.0
2 2 2 2 2
2
0
3
2
0
3
2
0
3
2
0
3
0
3
40
99
50
99
50
99
50
SR
0
0
0
0
0
1
0
4
0
0
3
30
99
50
99
50
99
50
AC
1
1
1
0
1
1
0
4
0
40
99
50
99
50
99
50
0
3
40
99
50
99
50
99
50
0
3
0
1
0
1
1
SC
0
0
4
0 ind
0
1
0
0
0
1
0
0
2
2
2
1
1 o o mem.telec
fin touche cachee relacher touche desiree O 01
RIgEL 6 - 17
x1
***
0---
lang type n. mot.
Dir preset autoset
SWO/OK
SWO/OK
SWC/OK
SWC/OK m1.o
2 1 m2.o
2 1
2 close m2.c
1 m1.c
2 1 open hydr elec
2
1
ITA fra deu eng esp int
EXT
AR sr ac sc ind
10--
VEREINFACHTES MENÜ
150-
*** Passwordeingabe
Anforderung mit Schutzniveaulogik eingestellt auf 1, 2, 3 oder 4
1520 ok
Aufwärts
Abwärts
Bestätigung/
Aufleuchten Display hydr : Hydrauliktrieb
ELEc: elektromechanischer Trieb
INT : Öffnung nach innen
EXT : Öffnung nach außen ar : Automatikbetrieb, Wohnbereich sr : Halbautomatikbetrieb, Wohnbereich ac : Automatikbetrieb, Hausbereich
Sc : Halbautomatikbetrieb, Hausbereich
Ind : Halbautomatikbetrieb, Hausbereich
2 1
Zurück zum
Hauptmenü
PRESET
PARAMETER
Arbeitszeit für motor 1
Arbeitszeit für motor 2
Verschiebungszeit Öffnung
Verschiebungszeit Schließung
Verlangsamungszeit
Motor 1 hydraulischer elektromechanischer hydraulischer Verlangsamungszeit
Motor 2
TCA elektromechanischer
Kraft Öffnung hydraulischer elektromechanischer hydraulischer
Kraft Schließung
Verlangsamungskraft elektromechanischer hydraulischer elektromechanischer
LOGIC
TCA
Einzelschrittbewegung
Voralarm
Totmann-Funktion
Impulssperre bei der Öffnung
Aufrechterhalten der Sperre hydraulischer elektromechanischer
SAFE1
Schutzniveau
DEFAULT AR SR AC SC ind
60.0
60.0
3
3
0
0
3
0
0
0
0
0
40
50
99
50
50
99
50
50
DEFAULT
AR
20
99
50
0
0
0
0
0
1
0
4
0
1
1
0
3
0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
2 2 2 2 2
2
0
2
0
2
0
2
0
2
0
3
0
3
50
99
50
40
99
50
99
SR
0
0
1
0
4
0
0
0
0
3
0
3
AC
0
1
1
0
4
0
1
1
1
50
99
50
30
99
50
99
3
0
3
50
99
50
40
99
50
99
3
0
3
50
99
50
40
99
50
99
SC ind
0
1
1
0
4
0
0
0
1
1
0
1
0
0
2
0
0
0
2 1
2
2
1
1 o o speichern hs ende
18 - RIgEL 6 verst. taste loslassen gevue. taste O 01
MENÚ SEMPLIFICADO x1
0---
lang
TIPO n. mot.
Dir preset autoset
SWO/OK
SWO/OK
SWC/OK
SWC/OK m1.o
2 1 m2.o
2 1
2 close m2.c
1 m1.c
2 1 open hidr elec
2
1
ITA fra deu eng esp int
EXT
AR sr ac sc ind
10-hIdr : Operador hidráulico
ELET: Operador electromecánico
2
2
2
2
1
1
1
1
150-
INT : apertura hacia dentro
EXT : apertura hacia afuera ar : funcionamiento automático, en viviendas sr : funcionamiento semi-aut, en viviendas ac : funcionamiento automático, en edificios
Sc : funcionamiento semi-aut, en edificios
Ind : funcionamiento con hombre presente
1520
RADIOM
FIN o o anad start suelte tecla deseada O 01 ok
LEYENDA
Desplazar hacia arriba
Desplazar hacia abajo
Confirmación/
Encendido pantalla
Retorno al menú principal
x1
***
0---
lang
TIPO n. mot.
Dir preset autoset
SWO/OK
SWO/OK
SWC/OK
SWC/OK m1.o
2 1 m2.o
2 1
2 close m2.c
1 m1.c
2 1 open hidr elec
2
1
ITA fra deu eng esp int
EXT
AR sr ac sc ind
10--
MENÚ SEMPLIFICADO
150-
*** Introducción contraseña.
Solicitud con lógica Nivel Protección configurada a 1, 2, 3, 4
1520 ok
LEYENDA
Desplazar hacia arriba
Desplazar hacia abajo
Confirmación/
Encendido pantalla
Retorno al menú principal hIdr
ELET:
INT
EXT ar : funcionamiento automático, en viviendas sr ac
Sc
Ind
: apertura hacia dentro
: funcionamiento semi-aut, en viviendas
: funcionamiento automático, en edificios
: funcionamiento semi-aut, en edificios
: funcionamiento con hombre presente
2
: Operador hidráulico
Operador electromecánico
: apertura hacia afuera
1
PRESET
PARAMETROS
Tiempo de trabajo motor 1
Tiempo de trabajo motor 2
Tiempo desfasaje apertura
Tiempo desfasaje cierre
Tiempo de deceleración motor 1 hidráulico electromecánico hidráulico Tiempo de deceleración motor 2
TCA electromecánico
Fuerza de apertura hidráulico electromecánico
Fuerza de cierre hidráulico electromecánico hidráulico
Fuerza deceleración electromecánico
LOGICA
TCA
Movimiento paso a paso pre alarma
Hombre presente
Bloquea impulsos en fase de apertura
Mantenimiento del bloqueo hidráulico electromecánico
SAFE1
Nivel protección
DEFAULT
60.0
60.0
3
3
0
0
40
50
50
50
DEFAULT
0
0
0
0
0
0
0
0
AR SR AC SC ind
AR
0
1
0
4
0
1
1
0
0
SR
0
1
0
4
0
0
0
0
0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
2 2 2 2 2
2
0
2
0
2
0
2
0
2
0
3
40
99
50
99
50
99
50
3
0
3
20
99
50
99
50
99
50
3
0
3
0
3
30
99
50
99
50
99
50
3
40
99
50
99
50
99
50
3
0
3
40
99
50
99
50
99
50
3
0
AC
1
1
0
4
0
1
1
1
0
SC
1
1
0
4
0
0
0
1
0 ind
0
1
0
0
2
0
0
0
1
2 1
2
2
1
1
RADIOM
FIN o o anad start suelte tecla deseada O 01
RIgEL 6 - 19
x1
***
0--10--
VEREENVOUDIGD MENU
150-
*** Password invoeren.
Aanvraag met logica Beschermingsniveau ingesteld op 1, 2, 3, 4
1520 ok lang type n. mot.
Dir preset autoset
SWO/OK
SWO/OK
SWC/OK
SWC/OK m1.o
2 1 m2.o
2 1
2 close m2.c
1 m1.c
2 1 open hydr elec
2
1
ITA fra deu eng esp int
EXT
AR sr ac sc ind
Doorloop op
Doorloop neer
Bevestig /
Aanschakeling display
Terugkeer naar het hoofdmenu
INT
EXT ar sr ac
Sc
: semi-automatische werking, gemeenschappelijk
Ind hydr:
ELET:
Hydraulische automatisering
Elektromechanische automatisering
: opening naar binnen
: opening naar buiten
: automatische werking, residentieel
: semi-automatische werking, residentieel
: automatische werking, gemeenschappelijk
: werking bij aanwezige persoon
2 1
PRESET
PARAMETERS
Werktijd motor 1
Werktijd motor 2
Tijd van faseverschil opening
Tijd van faseverschil sluiting
Tijd van afremming motor 1 hydraulische elektromechanische hydraulische Tijd van afremming motor 2
TCA elektromechanische
Openingskracht hydraulische elektromechanische
Sluitkracht
Afremmingskracht hydraulische elektromechanische hydraulische elektromechanische
LOGICA
TCA
Stap-voor-stap beweging pre-alarm persoon Aanwezig
Blokkeert impulsen bij opening
H a n d h a v i n g blokkering hydraulische elektromechanische
SAFE1
Beschermingsniveau
DEFAULT AR SR AC SC ind
60.0
60.0
3
3
0
0
40
50
50
50
DEFAULT
0
0
0
0
0
0
0
0
AR
0
1
0
4
0
0
0
1
1
SR
0
1
0
4
0
0
0
0
0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
2 2 2 2 2
2
0
2
0
2
0
2
0
2
0
3 3 3 3 3
0
3
99
50
99
50
40
99
50
0
3
99
50
99
50
20
99
50
0
3
30
99
50
99
50
99
50
0
3
99
50
99
50
40
99
50
0
3
99
50
99
50
40
99
50
AC
1
1
0
4
0
1
0
1
1
SC ind
1
1
0
4
0
1
0
0
0
0
1
0
0
2
0
1
0
0
2 1
2
2
1
1 o o mem.remotes
end
20 - RIgEL 6 hidden button release desidered button O 01
1)
3)
5)
7)
9)
11)
13)
15)
17)
19)
AUTOSET PER MOTORI CON FINECORSA / AUTOSET FOR MOTORS WITH LIMIT SWITCHES
AUTOCONFIGURATION POUR MOTEURS AVEC FIN DE COURSE / AUTOSET FÜR MOTOREN MIT ENDSCHALTER
AUTOSET PARA MOTORES CON FINAL DE CARRERA / AUTOSET VOOR MOTOREN MET EINDAANSLAGEN
SWC1 + SWC2
2)
S1
Chiuso - Closed
Fermé - geschlossenem
Cerrada - gesloten autoset S2
S3
M1 M2
4)
M1 m1.O
S1
S2
S3
Apertura M1
Opening M1
Ouverture M1
Öffnung M1
Apertura M1
Openings M1 SWO1
M2
D1
M1 M2
6)
M1 M2 m2.O
S1
S2
S3
Apertura M2
Opening M2
Ouverture M2
Öffnung M2
Apertura M2
Openings M2 SWO2 close m2.c
m1.c
open
. . . S1
S2
S3
. . . S1
S2
S3
S1
S2
S3
S1
S2
S3
M1
M1
M1
M1
M2
M2
M2
M2
Chiusura M2
Closing M2
Fermeture M2
Schließung M2
Cierre M2
Sluitings M2
8)
Chiusura M1
Closing M1
Fermeture M1
Schließung M1
Cierre M1
Sluitings M1
10)
12)
Apertura M1
Opening M1
Ouverture M1
Öffnung M1
Apertura M1
Openings M1
14)
Apertura M2
Opening M2
Ouverture M2
Öffnung M2
Apertura M2
Openings M2
M1
M1
SWC1
M1
SWO1
M1
M2
SWC2
M2
M2
M2
SWO2
. . .
. . .
S1
S2
S1
S2
S3
M1
M1
M2
M2
Chiusura M2
Closing M2
Fermeture M2
Schließung M2
Cierre M2
Sluitings M2
16)
18)
Chiusura M1
Closing M1
Fermeture M1
Schließung M1
Cierre M1
Sluitings M1
M1
M1
SWC1
M2
SWC2
M2
1)
SWC1 + SWC2
S1
S2
S3
S1
S2
S3
RIgEL 6 - 21
1)
AUTOSET PER MOTORI SPROVVISTI DI FINECORSA / AUTOSET FOR MOTORS WITH NO LIMIT SWITCHES
AUTOCONFIGURATION POUR MOTEURS SANS FIN DE COURSE / AUTOSET FÜR MOTOREN OHNE ENDSCHALTER
AUTOSET PARA MOTORES SIN FINAL DE CARRERA / AUTOSET VOOR MOTOREN ZONDER EINDAANSLAGEN
2)
Chiuso - Closed
Fermé - geschlossenem
Cerrada - gesloten autoset
S1
S2
S3
3)
5)
7)
9)
11)
13)
15)
17)
19) m1.O
S1
S2
S3 m2.O
S1
S2
S3 close m2.c
S1
S2
S3 m1.c
S1
S2
S3 open
. . . S1
S2
S3
. . .
. . .
. . .
S1
S2
S3
S1
S2
S3
S1
S2
S3
S1
S2
S3
M1
M1
M1
M1
M1
M1
M1
M1
M2
M2
M2
M2
M2
M2
M2
M2
S1
S2
S3
Apertura M1
Opening M1
Ouverture M1
Öffnung M1
Apertura M1
Openings M1
4)
Apertura M2
Opening M2
Ouverture M2
Öffnung M2
Apertura M2
Openings M2
6)
Chiusura M2
Closing M2
Fermeture M2
Schließung M2
Cierre M2
Sluitings M2
8)
Chiusura M1
Closing M1
Fermeture M1
Schließung M1
Cierre M1
Sluitings M1
10)
S1
S2
S3
12)
Apertura M1
Opening M1
Ouverture M1
Öffnung M1
Apertura M1
Openings M1
14)
Apertura M2
Opening M2
Ouverture M2
Öffnung M2
Apertura M2
Openings M2
S1
S2
S3
S1
S2
S3
S1
S2
S3
1)
Chiusura M2
Closing M2
Fermeture M2
Schließung M2
Cierre M2
Sluitings M2
16)
Chiusura M1
Closing M1
Fermeture M1
Schließung M1
Cierre M1
Sluitings M1
18)
M1
M1
M1
M1
M1
M1
M1
M1
M2
M2
M2
M2
M2
M2
M2
M2
D2
22 - RIgEL 6
1)
3) m1.O
S1
S2
S3
5) m2.O
S1
S2
S3
7) close m2.c
S1
S2
S3
9) m1.c
S1
S2
S3
11) open
. . . S1
S2
S3
13)
. . .
S3
S1
S2
M1
M1
M1
M1
M1
M1
15)
. . .
S1
S2
S3
17)
. . .
S1
S2
S3
19)
S1
S2
S3
M1
M1
M2
M2
M2
M2
M2
M2
8)
S1
S2
S3
10)
S1
S2
S3
12)
2) autoset
S1
S2
S3
4)
S1
S2
S3
M1
6)
S1
S2
S3
M1
M1
M1
M1
M2
M2
M2
M2
M2
D2
14)
M1 M2
M2
M2
S1
S2
S3
1)
16)
M1
18)
M1
M2
M2
50 70 71 72 76 77 78 79 80 81 82 83 84 85
E
1
2
51
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
SAFE 1
3
1
2
1
2
1
2
3
1
2
3
4
5
4
5
51
50
70
72
4
52
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
3
4
5
3
4
5
1
2
1
2
51
50
70
73
72
1 BAR / 1 BAR OP / 1 BAR CL
51
72
70
50
51
4
3
2
1
6
5
4
3
6
5
2
1
1 BAR / 1 BAR OP / 1 BAR CL
52
72
73
70
50
51
6
5
4
3
2
1
5
52
50
52
50
70
72
2 PHOT / 2 PHOT OP / 2 PHOT CL
1
2
1
2
1
2
1
2
3
4
5
3
4
5
1
2
1
2
3
4
3
4
1
2
1
2
51
50
70
72
51
50
73
70
2 BAR / 2 BAR OP / 2 BAR CL
52
72
70
50
51
4
3
2
1
6
5
52
70
73
50
51
4
3
2
1
6
5
4
3
6
5
2
1
SAFETY EDGE
BAR 8K2 / BAR 8K2 OP / BAR 8K2 CL
SAFETY EDGE
8,2Kohm 5%
1
2
SAFE 3
1 PHOT / 1 PHOT OP / 1 PHOT CL
51
50
1
2
1
2
52
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
3
4
5
3
4
5
1
2
1
2
1
2
3
1
2
3
4
5
4
5
51
50
76
78
77
51
50
76
77
52
50
52
50
2 PHOT / 2 PHOT OP / 2 PHOT CL
1
2
1
2
1
2
1
2
3
4
3
4
1
2
1
2
3
4
3
4
1
2
1
2
51
50
76
77
51
50
78
3
4
1 BAR / 1 BAR OP / 1 BAR CL
51
77
76
50
51
6
5
4
3
2
1
1 BAR / 1 BAR OP / 1 BAR CL
52
77
78
76
50
51
6
5
4
3
2
1
2 BAR / 2 BAR OP / 2 BAR CL
52
77
76
50
51
4
3
2
1
6
5
4
3
6
5
2
1
52
76
78
50
51
4
3
2
1
6
5
4
3
6
5
2
1
1
2
SAFE 5
1 PHOT / 1 PHOT OP / 1 PHOT CL
51
50
1
2
1
2
52
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
3
4
5
3
4
5
1
2
1
2
1
2
3
1
2
3
4
5
4
5
51
50
81
83
82
51
50
81
82
3
4
52
50
2 PHOT / 2 PHOT OP / 2 PHOT CL
52
50
1
2
1
2
1
2
1
2
3
4
3
4
1
2
1
2
3
4
3
4
1
2
1
2
51
50
81
82
51
50
83
81
1 BAR / 1 BAR OP / 1 BAR CL
51
82
81
50
51
6
5
4
3
2
1
1 BAR / 1 BAR OP / 1 BAR CL
52
82
83
81
50
51
6
5
4
3
2
1
2 BAR / 2 BAR OP / 2 BAR CL
52
82
81
50
51
4
3
2
1
6
5
4
3
6
5
2
1
52
81
83
50
51
4
3
2
1
6
5
4
3
6
5
2
1
SAFE2
1
51
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
3
4
3
4
1
2
1
2
SAFE 2
51
50
70
74
3 1 BAR / 1 BAR OP / 1 BAR CL
51
74
70
50
51
4
3
2
1
6
5
4
3
6
5
2
1
2
5
52
50
52
50
52
50
70
74
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
1
2
1
2
1
2
1
2
SAFETY EDGE
1
2
3
1
2
3
4
5
4
5
2 PHOT / 2 PHOT OP / 2 PHOT CL
3
4
3
4
1
2
1
2
51
50
70
75
74
4
3
4
3
4
1
2
1
2
51
50
70
74
51
50
75
70
52
70
75
50
51
BAR 8K2 / BAR 8K2 OP / BAR 8K2 CL
SAFETY EDGE
4
3
2
1
6
5
4
3
6
5
2
1
1 BAR / 1 BAR OP / 1 BAR CL
52
74
75
70
50
51
6
5
4
3
2
1
2 BAR / 2 BAR OP / 2 BAR CL
52
74
70
50
51
4
3
2
1
6
5
4
3
6
5
2
1
8,2Kohm 5%
1
2
51
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
SAFE 4
3
1
2
1
2
1
2
3
1
2
3
4
5
4
5
51
50
76
79
4
52
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
3
4
5
3
4
5
1
2
1
2
51
50
76
80
79
2 PHOT / 2 PHOT OP / 2 PHOT CL
52
50
1
2
1
2
52
50
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
51
50
76
79
51
50
80
76
1 BAR / 1 BAR OP / 1 BAR CL
51
79
76
50
51
6
5
4
3
2
1
1 BAR / 1 BAR OP / 1 BAR CL
52
79
80
76
50
51
6
5
4
3
2
1
2 BAR / 2 BAR OP / 2 BAR CL
52
79
76
50
51
4
3
2
1
6
5
52
76
80
50
51
4
3
2
1
6
5
4
3
6
5
2
1
1
2
51
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
SAFE 6
3
1
2
1
2
1
2
3
1
2
3
4
5
4
5
51
50
81
84
4
52
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
3
4
5
3
4
5
1
2
1
2
51
50
81
85
84
2 PHOT / 2 PHOT OP / 2 PHOT CL
52
50
1
2
1
2
52
50
1
2
1
2
3
4
1
2
3
4
1
2
3
4
3
4
1
2
1
2
51
50
81
84
51
50
85
81
1 BAR / 1 BAR OP / 1 BAR CL
51
84
81
50
51
6
5
4
3
2
1
1 BAR / 1 BAR OP / 1 BAR CL
52
84
85
81
50
51
6
5
4
3
2
1
2 BAR / 2 BAR OP / 2 BAR CL
52
84
81
50
51
4
3
2
1
6
5
4
3
6
5
2
1
52
81
85
50
51
4
3
2
1
6
5
4
3
6
5
2
1
RIgEL 6 - 23
A OPEN
B OPEN
Scheda di espansione
Expansion board
Carte d’expansion
Erweiterungskarte
Tarjeta de expansión
Uitbreidingskaart
C
F
D programmatore palmare universale
Universal palmtop programmer programmateur palmaire universel
Universal-Handprogrammiergerät programador portátil universal
Universele programmeerbare palmtop
G
UNIDA
ON ON
OFF OFF
1
70 71
STOP
!
+
8888 -
+
S1
S2
OK S3
2
ON ON
OFF OFF
3 <3s rst 8 -
+
S1
S2
OK S3
4
H
.
.
.
.
-
+
S1
S2
OK S3
5
8888 -
+
S1
S2
OK S3
6
24 - RIgEL 6
I
A OPEN
B OPEN
UNIDA
C
F
D
G
ON ON
OFF OFF
1
70 71
STOP
!
+
8888 -
+
S1
S2
OK S3
2
ON ON
OFF OFF
3 <3s rst 8 -
+
S1
S2
OK S3
4
H
.
.
.
.
-
+
S1
S2
OK S3
5
8888 -
+
S1
S2
OK S3
6
PROGRAMMAZIONE MENÙ CHRONO - CHRONO MENU PROGRAMMING - CHRONO MENU PROGRAMMING
PROGRAMMIERUNG MENÜ CHRONO - PROGRAMACIÓN MENÚ CHRONO - PROGRAMMERING CHRONO-MENU
I valori sono programmabili a step di 10 minuti - Values are programmable in 10 minutes’ steps
Les valeurs sont programmables par étape de 10 minutes - Die Werte können in Schritten von 10 Minuten programmiert werden
Los valores se puede programar con intervalos de 10 minutos - De waarden zijn programmeerbaar met stappen van 10 minuten
I
Lunedì
Monday
Lundi
Montag
Lunes
Maandag
Martedì
Tuesday
Mardi
Dienstag
Martes
Dinsdag
Mercoledì
Wednesday
Mercredi
Mittwoch
Miércoles
Woensdag giovedì
Thursday
Jeudi
Donnerstag
Jueves
Donderdag
Venerdì
Friday
Vendredi
Freitag
Viernes
Vrijdag
Sabato
Saturday
Samedi
Samstag
Sábado
Zaterdag
Domenica
Sunday
Dimanche
Sonntag
Domingo
Zondag
18:00
19:00
20:00
21:00
22:00
23:00
13:00
14:00
15:00
16:00
17:00
08:00
09:00
10:00
11:00
12:00
00:00
01:00
02:00
03:00
04:00
05:00
06:00
07:00
Fascia 1
Time band 1
Tranche1
Zeitraum 1
Franja 1
Bereik 1
Fascia 2
Time band 2
Tranche 2
Zeitraum 2
Franja 2
Bereik 2
Lunedì
Monday
Lundi
Montag
Lunes
Maandag
Martedì
Tuesday
Mardi
Dienstag
Martes
Dinsdag
Inizio / Beginning
Début / Beginn
Inicio / Begin
07.00
Fine / End
Fin / Ende
Final / Einde
12.00
Inizio / Beginning
Début / Beginn
Inicio / Begin
14.00
Fine / End
Fin / Ende
Final / Einde
18.00
Inizio / Beginning
Début / Beginn
Inicio / Begin
07.00
Fine / End
Fin / Ende
Final / Einde
12.00
Inizio / Beginning
Début / Beginn
Inicio / Begin
00.00
Fine / End
Fin / Ende
Final / Einde
00.00
Mercoledì
Wednesday
Mercredi
Mittwoch
Miércoles
Woensdag giovedì
Thursday
Jeudi
Donnerstag
Jueves
Donderdag
Inizio / Beginning
Début / Beginn
Inicio / Begin
06.00
Fine / End
Fin / Ende
Final / Einde
12.00
Inizio / Beginning
Début / Beginn
Inicio / Begin
14.00
Fine / End
Fin / Ende
Final / Einde
18.00
Inizio / Beginning
Début / Beginn
Inicio / Begin
07.00
Fine / End
Fin / Ende
Final / Einde
12.00
Inizio / Beginning
Début / Beginn
Inicio / Begin
00.00
Fine / End
Fin / Ende
Final / Einde
00.00
Venerdì
Friday
Vendredi
Freitag
Viernes
Vrijdag
Sabato
Saturday
Samedi
Samstag
Sábado
Zaterdag
Inizio / Beginning
Début / Beginn
Inicio / Begin
07.00
Fine / End
Fin / Ende
Final / Einde
12.00
Inizio / Beginning
Début / Beginn
Inicio / Begin
14.00
Fine / End
Fin / Ende
Final / Einde
18.00
Inizio / Beginning
Début / Beginn
Inicio / Begin
10.00
Fine / End
Fin / Ende
Final / Einde
12.00
Inizio / Beginning
Début / Beginn
Inicio / Begin
00.00
Fine / End
Fin / Ende
Final / Einde
00.00
Domenica
Sunday
Dimanche
Sonntag
Domingo
Zondag
Inizio / Beginning
Début / Beginn
Inicio / Begin
10.00
Fine / End
Fin / Ende
Final / Einde
12.00
Inizio / Beginning
Début / Beginn
Inicio / Begin
00.00
Fine / End
Fin / Ende
Final / Einde
00.00
Fascia non programmata. Viene lasciata a 0
No scheduled time zone. It is left at 0
Tranche non programmée. Est laissée à 0
Zeitraum nicht programmiert. Wird auf 0 gelassen
Franja no programada. Se deja en 0
Niet geprogrammeerd bereik Wordt losgelaten op 0
RIgEL 6 - 25
x2
***
0---
ALT
10-follow the user guide
1501520 ok
See PARAMETERS MENU
See LOGIC MENU
Add. 1ch
Add. 2ch
Add. 3ch
Add. 4ch erase 64 hidden butt hidden butt hidden butt hidden butt erase 1 ( 0001 ) release desired button release desired button release desired button release desired button ok
KO dis
If cancelled
If not present
If clone, it is disabled
See RADIO MENU
*** Password entry.
Request with Protection Level logic set to 1, 2, 3, 4
Scroll up
Scroll down
Confirm/Switch on display
Exit Menù language autoset
For AUTOSET menu, see simplified menu stat password vers
- + n. cycles
OK bft . . .
+ / -
No total manoeuvres(in hundreds)
OK 0000
+ / -
- + n. remotes
- + err
No radio controldevices memorised
OK 00
+ / -
List of last 30 errors
OK 01.33
02.01
........
30.15
+ / -
0--10--
PHCL
BAR baro barc
SWC1
SWO1
SWC2
SWO2
ER01
ER02
ER03
ER04 er06
ER07
ER08
ER1x *
ER3x *
ER7x *
ERf3
ERF9
STRE
STRI
OPEN
CLS
PED
TIME
STOP
PHOT
PHOP
150-
DESCRIPTION NOTES
START E external start input activated
START I internal start input activated
OpEN input activated
CLOSE input activated pED pedestrian input activated
TIMER input activation or activation time band
STOp input activated
Activation of pHOT photocell input or, if configured as verified photocell, Activation of the associated FAULT input
Activation of pHOT Op opening photocell input or, if configured as active verified photocell only when opening,
Activation of the associated FAULT input
Activation of pHOT CL closing photocell input or, if configured as active verified photocell only when closing, Activation of the associated FAULT input
Activation of BAR safety edge input or, if configured as verified safety edge, Activation of the associated FAULT input
Activation of BAR safety edge input with ACTIVE reversal ONLY
WHILE OpENINg, or, if configured as verified safety edge active only while opening, Activation of the associated FAULT input
Activation of BAR safety edge input with ACTIVE reversal ONLY
WHILE CLOSINg, or, if configured as verified safety edge active only while closing, Activation of the associated FAULT input
SWC1 motor 1 closing limit switch input activated
SWO1 motor 1 opening limit switch input activated
SWC2 motor 2 closing limit switch input activated
SWO2 motor 2 opening limit switch input activated photocell test failed
Safety edge test failed
Opening photocell test failed
Closing photocell test failed
8k2 safety edge test failed
Opening safety edge test failed
Closing safety edge test failed
Board hardware test error
Reverse due to obstacle - Amperostop
Internal system supervision control error.
Error in setting the SAFE inputs
Solenoid lock output overload
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/logic setting
Check photocell connection and/or parameter/logic setting
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
- Check connections to motor
- Hardware problems with board (contact technical assistance)
Check for obstacles in path
Try switching the board off and back on again. If the problem persists, contact the technical assistance department.
Check the setting of the SAFE inputs is correct
-Check lock connections
- Unsuitable lock
* X = 0, 1, .., 9, A, B, C, D, E, F
1520 prg
38 - RIgEL 6
chrono
DAY sunday monday tuesday wednesday thursday
| friday saturday
ZONE
01
....
....
02
....
02
01
01
02
....
BEGINNING
[00:00 - 24:00]
END
[00:00 - 24:00]
10-0
00-0
07-0
14-0
....
....
....
07-0
14-0
....
12-0
00-0
12-0
18-0
....
....
....
12-0
18-0
....
hh-MM sunday monday tuesday wednesday thursday friday saturday
00
[00-23]
Adjusts hour
00
[00:59]
Adjusts minutes
Setting the clock
RIgEL 6 - 39
INSTALLATION MANUAL
2) GENERAL INFORMATION
The RIGEL 6 control panel comes with standard factory settings. Any change must be made using the programmer with built-in display or universal handheld programmer. The Control unit completely supports the EELINK protocol.
Its main features are:
- Check of 1 or 2 single-phase motors fitted with thermostat
- Control of 1 or 2 single phase motors
Note: 2 motors of the same type must be used.
- Opening/closing limit switch control inputs, separate for each motor
- Separate inputs for safety devices
- Time band management
- Integrated obstacle detection
- Motor pre-heating with integrated sensor reading
- Adjustable electrodynamic braking
- Approach speed slow-down
- Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance or replacement easier. It comes with a series of prewired jumpers to make the installer’s job on site easier.
The jumpers concern terminals: 41-42, 41-43, 41-44, 41-45, 70-71, 70-72,
AUx 3
LOCK
Dimensions
Fuses
N° of combinations
(*other voltages to order)
TESTING
panel controls (checks) the run relays, triacs and safety devices (photocells and edges), before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working properly and check the wiring.
ATTENTION! if the leaf is installed in a public area or if an automatic operating mode is enabled, we recommend a pair of photocells is installed at a height of 5 cm together with another pair at a height of 40-50 cm. Automatic mode means any control not voluntarily activated by the user (example: TCA function, chrono, etc.)
3) TECHNICAL SPECIFICATIONS power supply 220-230V 50/60Hz(*)
Low voltage/mains insulation > 2MOhm 500V
Dielectric rigidity mains/LV 3750V~ for 1 minute
Accessories power supply
AUx 0
80W MAx)
AUx 1
AUx 2
80W MAx)
AUx0+
AUx1+
AUx2=
80W MAx
NO contact (Max 24V~) 10W MAx
10W MAx see Fig. B see Fig. C
4 billion
63
Use cycle
Maximum motor power 220-230V
Maximum motor power110-120V continuous
-20°C/+50°C
2x375 W
1x750 W
2x320 W
1x390 W continuous 1 min. ON/
2 min. OFF
-20°C/+55°C -20°C/+50°C
2x250 W
1x500 W
2x650 W
1x750 W
1 min. ON/
2 min. OFF
-20°C/+55°C
2x500 W
1x750 W
M1+M2+AUX0+AUX1+AUX2+AUX3+LOCK= 1300W MAX T=+50°C
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
4) TUBE ARRANGEMENT Fi g. A
5) TERMINAL BOARD WIRING Fig. C
WARNINGS - When performing wiring and installation, refer to the standards in force and, whatever the case, apply good practice principles.
Wires carrying different voltages must be kept physically separate from each other, or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
essories po
40 - RIgEL 6
22
23
24
25
26
27
28
29
40
41
42
43
44
45
50
51
52
Terminal
L
N gND
10
11
12
14
15
16
20
21
Definition
LINE
NEUTRAL
EARTH
MOT1 RUN
MOT 1 COM
MOT1 RUN
MOT2 RUN
MOT 2 COM
MOT2 RUN
AUx 1 - 220-230V~ pOWERED CONTACT
AUx 1 - 220-230V~ pOWERED CONTACT
AUx 2 - FREE CONTACT
(N.O.)
AUx 3 - FREE CONTACT
(N.O.)
LOCK 12V
+ REF SWE
SWC 1
SWO 1
SWC 2
SWO 2
24V-
24V+
24 Vsafe+
Single-phase power supply 220-230V 50/60Hz(*)
Connection motor 1. Time lag during closing.
Connection motor 2. Time lag during opening.
Note: if “ 1 MOT.ON
.” = 1 do not connect any wires to terminals 14-15-16
AUx 0 configurable output - Default setting FLASHINg LIgHT.
MONOSTABLE RADIO CHANNEL/ SCA gATE OpEN LIgHT/ COURTESY LIgHT command/ ZONE LIgHT command/ STAIR LIgHT/ gATE OpEN ALARM/ FLASHINg LIgHT/ SOLENOID LATCH/ MAgNETIC LOCK/ MAINTENANCE/ FLASHINg LIgHT AND MAINTE-
NANCE / gATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to “AUx output configuration” table.
AUx 1 configurable output - Default setting ZONE LIgHT Output.
MONOSTABLE RADIO CHANNEL/ SCA gATE OpEN LIgHT/ COURTESY LIgHT command/ ZONE LIgHT command/ STAIR LIgHT/ gATE OpEN ALARM/ FLASHINg LIgHT/ SOLENOID LATCH/ MAgNETIC LOCK/ MAINTENANCE/ FLASHINg LIgHT AND MAINTE-
NANCE / gATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to “AUx output configuration” table.
AUx 2 configurable output - Default setting SCA gATE OpEN LIgHT Output.
MONOSTABLE RADIO CHANNEL/ SCA gATE OpEN LIgHT/ COURTESY LIgHT command/ ZONE LIgHT command/ STAIR LIgHT/ gATE OpEN ALARM/ FLASHINg LIgHT/ SOLENOID LATCH/ MAgNETIC LOCK/ MAINTENANCE/ FLASHINg LIgHT AND MAINTE-
NANCE / gATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to “AUx output configuration” table.
AUx 3 configurable output - Default setting MONOSTABLE RADIO CHANNEL Output.
MONOSTABLE RADIO CHANNEL/ SCA gATE OpEN LIgHT/ COURTESY LIgHT command/ ZONE LIgHT command/ STAIR LIgHT/ gATE OpEN ALARM/ FLASHINg LIgHT/ SOLENOID LATCH/ MAgNETIC LOCK/ MAINTENANCE/ FLASHINg LIgHT AND MAINTE-
NANCE / gATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to “AUx output configuration” table.
Type of lock logic= 0 - 12V solenoid latch output.
Output activated with a pulse each time gate is opened or closed
(MODEL ECB)
Type of lock logic= 1 - 12V magnetic lock output.
Output activated when gate is closed or closing
Not used
Limit switch common
Motor 1 closing limit switch SWC1 (N.C.).
Motor 1 opening limit switch SWO1 (N.C.).
Motor 2 closing limit switch SWC2 (N.C.).
Motor 2 opening limit switch SWO2 (N.C.).
Accessories power supply output.
Description
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
Terminal
60
61
79
80
81
82
83
84
77
78
72
73
74
75
76
85
Y
#
65
70
71
62
63
64
Definition
Common
IC 1
IC 2
Common
IC 3
IC 4
Common
STOp
SAFE 4
FAULT 4
Common
SAFE 5
FAULT 5
SAFE 6
SAFE 1
FAULT 1
SAFE 2
FAULT 2
Common
SAFE 3
FAULT 3
FAULT 6
ANTENNA
SHIELD
NTC
INSTALLATION MANUAL
Description
IC 1 and IC 2 inputs common
Configurable command input 1 (N.O.) - Default START E.
START E / START I / OpEN / CLOSE / pED / TIMER / TIMER pED
Refer to the “Command input configuration” table.
Configurable command input 2 (N.O.) - Default pED.
START E / START I / OpEN / CLOSE / pED / TIMER / TIMER pED
Refer to the “Command input configuration” table.
IC 3 and IC 4 inputs common
Configurable command input 3 (N.O.) - Default OpEN.
START E / START I / OpEN / CLOSE / pED / TIMER / TIMER pED
Refer to the “Command input configuration” table.
Configurable command input 4 (N.O.) - Default CLOSE.
START E / START I / OpEN / CLOSE / pED / TIMER / TIMER pED
Refer to the “Command input configuration” table.
STOp, SAFE 1 and SAFE 2 inputs common
The command stops movement. (N.C.)
If not used, leave jumper inserted.
Configurable safety input 1 (N.C.) - Default pHOT. pHOT / pHOT TEST / pHOT Op / pHOT Op TEST / pHOT CL / pHOT CL TEST / BAR / BAR TEST / BAR 8K2/ BAR Op / BAR Op TEST / BAR
8K2 Op/ BAR CL / BAR CL TEST / BAR 8K2 CL.
Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 1.
Configurable safety input 2 (N.C.) - Default BAR. pHOT / pHOT TEST / pHOT Op / pHOT Op TEST / pHOT CL / pHOT CL TEST / BAR / BAR TEST / BAR 8K2/ BAR Op / BAR Op TEST / BAR
8K2 Op/ BAR CL / BAR CL TEST / BAR 8K2 CL
Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 2.
SAFE 3 and SAFE 4 inputs common
Configurable safety input 3 (N.C.) - Default pHOT Op. pHOT / pHOT TEST / pHOT Op / pHOT Op TEST / pHOT CL / pHOT CL TEST / BAR / BAR TEST / BAR Op / BAR Op TEST / BAR CL / BAR CL
TEST /
Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 3.
Configurable safety input 4 (N.C.) - Default pHOT CL. pHOT / pHOT TEST / pHOT Op / pHOT Op TEST / pHOT CL / pHOT CL TEST / BAR / BAR TEST / BAR Op / BAR Op TEST / BAR CL / BAR CL
TEST /
Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 4.
SAFE 5 and SAFE 6 inputs common
Configurable safety input 5 (N.C.) - Default pHOT. pHOT / pHOT TEST / pHOT Op / pHOT Op TEST / pHOT CL / pHOT CL TEST / BAR / BAR TEST / BAR Op / BAR Op TEST / BAR CL / BAR CL
TEST /
Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 5.
Configurable safety input 6 (N.C.) - Default BAR. pHOT / pHOT TEST / pHOT Op / pHOT Op TEST / pHOT CL / pHOT CL TEST / BAR / BAR TEST / BAR Op / BAR Op TEST / BAR CL / BAR CL
TEST /
Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 6.
Antenna input.
Use an antenna tuned to 433MHz. Use Rg58 coax cable to connect the Antenna and Receiver. Metal bodies close to the antenna can interfere with radio reception. If the transmitter’s range is limited, move the antenna to a more suitable position.
Input for temperature sensor connection
AUX output configuration
Aux logic= 0 - MONOSTABLE RADIO CHANNEL output.
Contact stays closed for 1s when radio channel is activated.
Aux logic= 1 - SCA gATE OpEN LIgHToutput.
Contact stays closed during opening and with leaf open, intermittent during closing, open with leaf closed.
Aux logic= 2 - COURTESY LIgHT command output.
Contact stays on for 90 seconds after the last operation.
Aux logic= 3 - ZONE LIgHT command output.
Contact stays closed for the full duration of operation.
Aux logic= 4 - STAIR LIgHT output.
Contact stays closed for 1 second at start of operation.
Aux logic= 5 - gATE OpEN ALARM output.
Contact stays closed if the leaf stays open for double the set TCA time.
Aux logic= 6 - FLASHINg LIgHT output.
Contact stays closed while leaves are operating.
Aux logic= 7 - SOLENOID LATCH output.
Contact stays closed for 2 seconds each time gate is opened or closed.
Aux logic= 8 - MAgNETIC LOCK output.
Contact stays closed when gate is closed and while it is closing.
Aux logic= 9 - MAINTENANCE output.
Contact stays closed once the value set for the Maintenance parameter is reached, to report that maintenance is required.
Aux logic= 10 - FLASHINg LIgHT AND MAINTENANCE output.
Contact stays closed while leaves are operating. If the value set for the Maintenance parameter is reached, once the gate has finished moving and the leaf is closed, the contact closes for 10 sec. and opens for 5 sec. 4 times to report that maintenance is required.
RIgEL 6 - 41
INSTALLATION MANUAL
AUX output configuration
Aux logic= 11 - Not available
Aux logic= 12 - Not available
Aux logics= 13 - gATE STATUS output
Contact stays closed while gate is closed.
AUx logics= 14 - BISTABLE RADIO CHANNEL output
The contact changes status (open-closed) when the radio channel is activated
AUx logics= 15 - TIMED RADIO CHANNEL output
The contact remains closed for a programmable length of time when the radio channel is activated (output time)
If, during this time, the button is pressed again, counting starts all over again.
Command input configuration
IC logic= 0 - Input configured as Start E. Operation according to STEP-BY-STEP MOV . logic. External start for traffic light control.
IC logic= 1 - Input configured as Start I. Operation according to STEP-BY-STEP MOV . logic. Internal start for traffic light control.
IC logic= 2 - Input configured as Open.
The command causes the leaves to open. If the input stays closed, the leaves stay open until the contact is opened. When the contact is open, the automated device closes following the TCA time, where activated.
IC logic= 3 - Input configured as Closed.
The command causes the leaves to close.
IC logic= 4 - Input configured as ped.
The command causes the leaf to open to the pedestrian (partial) opening position. Operation according to STEP-BY-STEP . logic
IC logic= 5 - Input configured as Timer.
Operation same as open except closing is guaranteed even after a mains power outage.
IC logic= 6 - Input configured as Timer ped.
The command causes the leaf to open to the pedestrian (partial) opening position. If the input stays closed, the leaf stays open until the contact is opened. If the input stays closed and a Start E,
Start I or Open command is activated, a complete opening-closing cycle is performed before returning to the pedestrian opening position. Closing is guaranteed even after a mains power outage.
Safety input configuration
SAFE logic= 0 - Input configured as phot (photocell) non tested (*). (fig.F, ref.1).
Enables connection of devices not equipped with supplementary test contacts. When beam is broken, photocells are active during both opening and closing. When beam is broken during closing, movement is reversed only once the photocell is cleared. If not used, leave jumper inserted.
SAFE logic= 1 - Input configured as phot test (tested photocell). (fig.F, ref.2).
Switches photocell testing on at start of operation. When beam is broken, photocells are active during both opening and closing. When beam is broken during closing, movement is reversed only once the photocell is cleared.
SAFE logic= 2 - Input configured as phot op (photocell active during opening only) non tested (*). (fig.F, ref.1).
Enables connection of devices not equipped with supplementary test contacts. In the event beam is broken, photocell operation is disabled during closing. During opening, stops motion for as long as the photocell beam stays broken. If not used, leave jumper inserted.
SAFE logic= 3 - Input configured as phot op test (tested photocell active during opening only (fig.F, ref.2).
Switches photocell testing on at start of operation. In the event beam is broken, photocell operation is disabled during closing. During opening, stops motion for as long as the photocell beam stays broken.
SAFE logic= 4 - Input configured as phot cl (photocell active during closing only) non tested (*). (fig.F, ref.1).
Enables connection of devices not equipped with supplementary test contacts. In the event beam is broken, photocell operation is disabled during opening. During closing, movement is reversed immediately. If not used, leave jumper inserted.
SAFE logic= 5 - Input configured as phot cl test (tested photocell active during closing only (fig.F, ref.2).
Switches photocell testing on at start of operation. In the event beam is broken, photocell operation is disabled during opening. During closing, movement is reversed immediately.
SAFE logic= 6 - Input configured as Bar (safety edge) non tested (*). (fig.F, ref.3).
Enables connection of devices not equipped with supplementary test contacts. The command reverses movement for 2 sec.. If not used, leave jumper inserted.
SAFE logic= 7 - Input configured as Bar (tested safety edge (fig.F, ref.4).
Switches safety edge testing on at start of operation. The command reverses movement for 2 sec.
SAFE logic= 8 - Input configured as Bar 8k2 (fig.F, ref.5). Input for resistive edge 8K2.
The command reverses movement for 2 sec.
SAFE logic=9 Input configured as Bar op, safety edge with active inversion only while opening, if activated while closing, the automation stops (STOp) (Fig. F, ref. 3).
Allows connecting devices not fitted with supplementary test contact. The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the automation to stop. If not used, leave jumper inserted.
SAFE logic=10 Input configured as Bar op test, safety edge checked with active inversion only while opening, if activated while closing, the automation stops (STOp) (Fig. F, ref. 4).
Activates testing safety edges when starting operation. The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the automation to stop.
SAFE logic=11 Input configured as Bar 8k2 op, 8k2 safety edge with active inversion only while opening, if activated while closing, the automation stops (STOp) (Fig. F, ref. 5).
The operation while opening causes the movement to be reversed for 2 seconds, the operation while closing causes the automation to stop.
SAFE logic=12 Input configured as Bar cl, safety edge with active inversion only while closing, if activated while opening, the automation stops (STOp) (Fig. F, ref. 3).
Allows connecting devices not fitted with supplementary test contact. The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening causes the automation to stop. If not used, leave jumper inserted.
SAFE logic=13 Input configured as Bar cl test, safety edge checked with active inversion only while closing, if activated while opening, the automation stops (STOp) (Fig. F, ref. 4).
Activates testing safety edges when starting operation. The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening causes the automation to stop.
SAFE logic=14 Input configured as Bar 8k2 cl, safety edge with active inversion only while closing, if activated while opening, the automation stops (STOp) (Fig. F, ref. 5).
The operation while closing causes the movement to be reversed for 2 seconds, the operation while opening causes the automation to stop.
(*) If “D” type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months.
42 - RIgEL 6
6.1) TESTED DEVICES Fig. F
6.2) CONNECTION OF 1 PAIR OF NON-TESTED PHOTOCELLS FIG. D
7) CALLING UP MENUS: FIG. 1
7.1) PARAMETERS MENU (
PARA
) (PARAMETERS TABLE “A”)
7.2) LOGIC MENU (
LOGIC
) (LOGIC TABLE “B”)
7.3) RADIO MENU ( radio
) (RADIO TABLE “C”)
- IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the first transmitter assigns the RECEIVER’S
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced features:
• Cloning of master transmitter (rolling code or fixed code).
• Cloning to replace transmitters already entered in receiver.
• Transmitter database management.
• Receiver community management.
To use these advanced features, refer to the universal handheld programmer’s instructions and to the general receiver programming guide.
If a 4-channel remote control is used, keep one for the STOp function.
7.4) DEFAULT MENU ( default
)
Restores the controller’s DEFAULT factory settings. Following this reset, you will need to run the AUTOSET function again.
7.5) LANGUAGE MENU ( language
)
Used to set the programmer’s language on the display.
7.6) AUTOSET MENU ( AUTOset )
Autoset for motors with limit switches ( Fig. E1 ):
1 - place the leaves at the closing limit switch.
2 - Start an autoset from the relative menu, press the OK button start motor 1’s opening manoeuvre.
3 - The display shows “M1.o”.
4 - Wait for the opening limit switch to be triggered to finish motor 1’s opening manoeuvre.
5 - Motor 2 starts opening automatically. A displays “M2.o”.
6 - Wait for the opening limit switch to be triggered to finish motor 2’s opening manoeuvre, the display shows the message “CLOSE”.
7 - press the OK button to start motor 2’s closing manoeuvre. A displays “M2.c”.
8 - Wait for the closing limit switch to be triggered to finish motor 2’s closing manoeuvre.
9 - Motor 1 starts closing automatically. A displays “M1.c”.
10 - Wait for the closing limit switch to be triggered to finish motor 1’s closing manoeuvre.
If the work time has been stored correctly, the display shows “OpEN”.
11 - press the OK button to start the second cycle and calculate the torque value required for the leaf/ves to move, the display shows “M1.o”.
12 - Wait for the opening limit switch to be triggered to finish motor 1’s opening manoeuvre.
13 - Motor 2 starts opening automatically. A displays “M2.o”.
14 - Wait for the opening limit switch to be triggered to finish motor 2’s opening manoeuvre, the display shows the message “CLOSE”.
15 - press the OK button to start motor 2’s closing manoeuvre. A displays “M2.c”.
16 - Wait for the closing limit switch to be triggered to finish motor 2’s closing manoeuvre.
17 - Motor 1 starts closing automatically. A displays “M1.c”.
18 - Wait for the closing limit switch to be triggered to finish motor 1’s closing manoeuvre.
19 - If the autoset has completed correctly, the display shows “OK”, if autoset fails, the display shows the message “KO” and the operation must be repeated from phase 1.
If motor 1 is set to active, the phases relative to motor 2 are not performed.
Autoset for motors with no limit switches ( Fig. E2 ):
1 - place the leaves at the closing stops.
2 - start an autoset from the relative menu, pressing the OK button start motor
1’s opening manoeuvre.
3 - The display shows “M1.o”.
4 - ress the OK button to finish motor 1’s opening manoeuvre. A displays “M2.o”.
5 - Motor 2 starts opening automatically.
6 - press the OK button to finish motor 2’s opening manoeuvre, the display shows “CLOSE”.
7 - press the OK button to start motor 2’s closing manoeuvre. A displays “M2.c”
8 - press the OK button to finish motor 2’s closing manoeuvre. A displays “M1.c”
9 - Motor 1 starts closing automatically.
10 - press the OK button to finish motor 1’s closing manoeuvre.
If the work time has been stored correctly, the display shows “OpEN”.
11 - press the OK button to start the second cycle and calculate the torque value required for the leaf/ves to move, the display shows “M1.o”.
12 - Wait for motor 1’s work time to intervene to finish motor 1’s opening manoeuvre.
13 - Motor 2 starts opening automatically. A displays “M2.o”.
14 - Wait for Motor 2’s work time to intervene to finish motor 2’s opening manoeuvre, the display shows the message “CLOSE”.
15 - press the OK button to start motor 2’s closing manoeuvre. A displays “M2.c”
16 - Wait for motor 2’s work time to intervene to finish motor 2’s closing manoeuvre.
17 - Motor 1 starts closing automatically. A displays “M1.c”
18 - Wait for motor 1’s work time to intervene to finish motor 1’s closing manoeuvre.
19 - If the autoset has completed correctly, the display shows “OK”, if autoset fails, the display shows the message “KO” and the operation must be repeated from phase 1.
If motor 1 is set to active, the phases relative to motor 2 are not performed.
During this stage, it is important to avoid breaking the photocells’ beams, causing the safety devices to intervene, and not to use the START, STOp, OpEN and CLOSE controls or the display.
Once this operation is completed, the control unit will have automatically set the optimum parameters and work times. Check them and, where necessary,
INSTALLATION MANUAL edit them as described in the programming section.
WARNING!! Check that the force of impact measured at the points by standard EN 12453.
The impact forces must be limited with the use of active coasts ac-
Warning!! While the autoset function is running, the obstacle detection function is not active. Consequently, the installer must monitor the automated system’s movements and keep people and property out of range of the automated system.
7.7)INSTALLATION TEST PROCEDURE
1. Apply pressure-sensitive or electro-sensitive protective devices (such as a safety edge)
2. Run the AUTOSET cycle (*)
3. Check the impact forces: if they fall within the limits. Skip to point 5 of the procedure, otherwise
4. Allow the drive to move only in “Deadman” mode
5. Make sure all devices designed to detect obstacles within the system’s operating range are working properly
(*) Before running the autoset function, make sure you have performed all the assembly and make-safe operations correctly, as set out in the installation warnings in the drive’s manual and have set the opening/closing strength, slow-down and slow-down time parameters.
7.8) STATISTICS MENU
Used to view the version of the board, the total number of operations (in hundreds), the number of transmitters memorized and the last 30 errors (the first 2 digits indicate the position, the last 2 give the error code). Error 01 is the most recent.
7.9) PASSWORD MENU
Used to set a password for the board’s wireless programming via the U-link network.
With “pROTECTION LEVEL” logic set to 1,2,3,4, the password is required to access the programming menus. After 10 consecutive failed attempts to log in, you will need to wait 3 minutes before trying again. During this time, whenever an attempt is made to log in, the display will read “BLOC”. The default password is 1234.
7.10) CHRONO MENU Fig.J
Allows setting the operation by time bands.
Up to two daily time bands during which the gate remains open (from Monday to Sunday) can be set.
Within the time slot opening of the doors is performed that remain open until the end of the time slot.
9) CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD
PROGRAMMER. Refer to specific manual.
10) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
The use of some models causes lowered radio capacity. Adjust the system using an appropriate antenna tuned to 433MHxz.
11) RESTORING FACTORY SETTINGS (Fig.I)
WARNING: this operation will restore the control unit’s factory settings and all transmitters stored in its memory will be deleted.
WARNINg! Incorrect settings can result in damage to property and injury to people and animals.
- Cut off power to the board (Fig.I ref.1)
- Open the Stop input and press the - and OK keys together (Fig.I ref.2)
- Switch on the board’s power (Fig.I ref.3)
- The display will read RST; confirm within 3 sec. by pressing the OK key (Fig.I ref.4)
- Wait for the procedure to finish (Fig.I ref.5)
- procedure finished (Fig.I ref.6)
WARNING! Incorrect settings can result in damage to property and injury to people and animals. provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.
Impact forces can be reduced by using deformable edges.
For best results, it is advisable to run the autoset function with the motors idle (i.e. not overheated by a considerable number of consecutive operations).
RIgEL 6 - 43
INSTALLATION MANUAL
TABLE “A” - PARAMETERS MENU - ( PARA )
Parameter min. max. Default Personal vork. t. ot.1
3.0
180.0
60.0
vork. t. ot.2
PARTIAL
OPENING
OPEN DELAY
TI E
CLS DELAY
TI E slov - dovn t. ot.1
slov - dovn t. ot.2
TCA
TRF.LGHT.CLR.T
3.0
3
0
0
0
0
0
1
180.0
90
10
25
30
30
120
180
60.0
6
3
3
0
0
10
40 output time
OP.FORCE
CLS.FORCE
slwd.force
brake e er. brake preheat.
1
1
1
1
0
0
0
240
99
99
99
99
99
99
10
50
50
50
0
60
30
Definition
Operation time motor 1 [s]
Operation time motor 2 [s] partial opening M1 [s]
Motor 2 opening delay time [s]
Description
Sets the value of motor 1 / 2 work time in seconds
At the end of an autoset it is set with the actual motor work value
Time of partial opening following the activation of motor M1 pED pedestrian control
Motor 2 opening delay time with respect to motor 1.
Motor 1 closing delay time [s] Motor 1 closing delay time with respect to motor 2.
Slow-down time motor 1 [s]
Slow-down time motor 2 [s]
Sets the approach slow-down time. The slow-down time is subtracted from the work time.
NOTE:
NOTE:
Use this function only if a limit switch is installed.
Do not use with hydraulic motors. (***)
Automatic closing time [s] Waiting time before automatic closing.
Time-to-clear traffic light zone [s]
Time-to-clear for the zone run through by traffic controlled by the traffic light.
Activation time of the timed output [s]
Activation length of timed radio channel output in seconds
Leaf force during opening [%]
WARNING: It affects impact force directly: make sure that current safety requirements are met with the set value (*).
If necessary, install anti-crushing safety devices (**).
(***)
Force exerted by leaf/leaves during closing.
Represents the percentage of force delivered at speed in comparison with the maximum value.
Leaf force during closing [%]
Force exerted by leaf/leaves during opening.
Represents the percentage of force delivered at speed in comparison with the maximum value.
WARNING: It affects impact force directly: make sure that current safety requirements are met with the set value (*).
If necessary, install anti-crushing safety devices (**).
(***)
Force exerted by leaf / and slowdown.
It represents the percentage of power supplied to slow down.
Forza motori in rallentamento
[%]
WARNING: It affects impact force directly: make sure that current safety requirements are met with the set value (*).
If necessary, install anti-crushing safety devices (**).
(***)
Braking
[%]
Set the braking value from 0% (min.) to 99% (max.) according to the gate weight and the mechanical demands involved.
Emergency braking
[%] preheating
[%]
Sets the value between 0% (min.) and 99% (max.) of emergency braking, that is performed by activating the safety controls present at the inputs configured as BAR safety edge.
Set the percentage value of the current from 0 (deactivated pre-heating) to 99% which can be made to pass through the motor windings to keep them at the right temperature.
NOTE: the NTC temperature sensor must be connected
The sensor must be placed and fixed in contact with the motor to detect the outside temperature
It allows activating obstacle detection.
The function is disabled when the parameter is set to 0, setting the value between 1 and the maximum value, obstacle sensitivity can be increased (max value = max sensitivity).
It works only with the limit switches.
obst.sens.
0 99 0 Obstacle sensitivity
ATTENTION: This obstacle detection function does not guarantee compliance with the safety regulations in force (*). To comply with the current safety regulations, install adequate anti-crushing safety devices (**).
ATTENTION: The system detects the obstacle only if the leaf is stopped; no obstacles breaking the leaf without managing to stop it are detected.
Detection takes place only if the leaf meeting the obstacle is moving at normal speed. The obstacle is not detected during slow-down.
(***)
Maintenance 0 250 0 programming number of operations for maintenance threshold
[in hundreds]
Allows you to set a number of operations after which the need for maintenance will be reported on the AUx output configured as Maintenance or Flashing Light and
Maintenance .
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) The impact forces must be limited using active coasts comply with EN12978
(***) CAUTION: After a parameter change will need to run an autoset function if the “obstacle sensitivity” is active.
44 - RIgEL 6
INSTALLATION MANUAL
TABLE “B” - LOGIC MENU - ( logic )
Logic
TCA
FAST CLS.
STEP-BY-STEP
MOVEMNT
Definition
Automatic Closing
Time
Fast closing
Step-by-step movement
Default
0
0
0
Cross out setting used
0
1
0
1
0
1
2
Optional extras
Logic not enabled
Switches automatic closing on
Logic not enabled
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I, ped operate with 4-step logic.
Inputs configured as Start E, Start I, ped operate with 3-step logic. pulse during closing reverses movement.
CLOSED step-by-step mov.
2 STEP 3 STEP 4 STEP
OpENS
DURINg
CLOSINg
OpENS OpENS
STOpS
Inputs configured as Start E, Start I, ped operate with 2-step logic. Movement reverses with each pulse.
OpEN
DURINg
OpENINg
CLOSES
CLOSES CLOSES
STOp + TCA STOp + TCA
AFTER STOp OpENS OpENS OpENS
PRE-ALARM
HOLD-TO-RUN
IBL OPEN
|IBL TCA
IBL CLOSE
RAM BLOW C.OP
RAM BLOW C.CL
BLOC PERSIST
PRESS SWC
1 MOT.ON
OPEN IN OTHER
DIRECT.
SAFE 1
Pre-alarm
Deadman
Block pulses during opening
Block pulses during
TCA
Block pulses during closing
Hammer during opening
Hammer during closing
Stop maintenance
Closing limit switch pressure
1 motor active
Open in other direction
Configuration of safety input SAFE 1.
72
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
1
0
1
1
0
1
0
0
1
1
2
0
1
0
1
2
0
1
0
1
0
1
The flashing light comes on at the same time as the motor(s) start.
The flashing light comes on approx. 3 seconds before the motor(s) start.
pulse operation.
Deadman mode.
Input 61 is configured as OpEN Up.
Input 62 is configured as CLOSE Up.
Operation continues as long as the OpEN Up or CLOSE Up keys are held down.
WARNING: safety devices are not enabled.
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is switched to Deadman mode, which will stay active until the OpEN Up or CLOSE Up keys are released.
Input 61 is configured as OpEN Up.
Input 62 is configured as CLOSE Up.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled. pulse from inputs configured as Start E, Start I, ped has effect during opening. pulse from inputs configured as Start E, Start I, ped has no effect during opening. pulse from inputs configured as Start E, Start I, ped has effect during TCA pause. pulse from inputs configured as Start E, Start I, ped has no effect during TCA pause. pulse from inputs configured as Start E, Start I, ped has effect during closing. pulse from inputs configured as Start E, Start I, ped has no effect during closing.
Logic not enabled
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the solenoid lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Logic not enabled
Before closing completely, the gate pushes for approx. 2 seconds as it opens. This allows the solenoid lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Logic not enabled
If motors stay idle in fully open or fully closed position for more than one hour, they are switched on in the direction of the stop for approx. 3 seconds. This operation is performed every hour.
NB: In hydraulic motors, this function serves to compensate a possible reduction in the volume of oil due to a drop in temperature during extended pauses, such as during the night, or due to internal leakage.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Movement is stopped only when the closing limit switch trips: in this case, the tripping of the closing limit switch must be adjusted accurately ( Fig.G Ref.B
).
Use when there is a mechanical stop in closed position.
This function allows leaves to press against the mechanical stop without the Amperostop sensor interpreting this as an obstacle.
Thus the rod continues its stroke for a few seconds after meeting the closing limit switch or as far as the mechanical stop. In this way, the leaves come to rest perfectly against the stop by allowing the closing limit switches to trip slightly earlier ( Fig.G Ref.A
).
Both motors active (2 leaves).
Only motor 1 active (1 leaf).
Standard operating mode ( See Fig.G Ref. C ).
Opens in other direction to standard operating mode ( See Fig. G Ref.D
)
Input configured as phot (photocell).
Input configured as phot test (tested photocell).
Input configured as phot op (photocell active during opening only).
RIgEL 6 - 45
Logic
SAFE 2
SAFE 3
SAFE 4
SAFE 5
SAFE 6
IC 1
IC 2
IC 3
IC 4
1ch
2ch
3 ch
4 ch
AUX 0
AUX 1
AUX 2
AUX 3
LOCK
FIXED CODE
INSTALLATION MANUAL
Definition
Configuration of safety input SAFE 2.
74
Configuration of safety input SAFE 3.
77
Configuration of safety input SAFE 4.
79
Configuration of safety input SAFE 4.
79
Configuration of safety input SAFE 6.
84
Configuration of command input IC 1.
Configuration of command input IC 2.
Configuration of command input IC 3.
Configuration of command input IC 4.
65
Configuration of the
1st radio channel command
Default
6
2
4
0
6
0
4
2
2
3
0
1
4
5
Cross out setting used
3
4
5
6
7
8
9
10
11
12
13
14
Optional extras
Input configured as phot op test (tested photocell active during opening only).
Input configured as phot cl (photocell active during closing only).
Input configured as phot cl test (tested photocell active during closing only).
Input configured as Bar, safety edge.
Input configured as Bar, tested safety edge.
Input configured as Bar 8k2 (Inactive on SAFE 3,4,5,6).
Input configured as Bar Op, safety edge with inversion active only while opening. If while closing, the movement stops.
Input configured as Bar Op TEST, safety edge tested with inversion active only while opening. If while closing, the movement stops.
Input configured as Bar Op 8k2, safety edge with inversion active only while opening. If while closing, the movement stops.
(Inactive on SAFE 3,4,5,6).
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the movement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening, the movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the movement stops.
(Inactive on SAFE 3,4,5,6).
Input configured as Start E.
Input configured as Start I.
Input configured as Open.
Input configured as Close.
Input configured as ped.
Input configured as Timer.
3
0
6 Input configured as Timer pedestrian.
Configuration of the
2nd radio channel command
Configuration of the
3rd radio channel command
Configuration of the
4th radio channel command
Configuration of
AUX 0 output. 20-21
Configuration of
AUX 1 output.
22-23
Configuration of
AUX 2 output.
24-25
Configuration of
AUX 3 output.
26-37
Type of lock.
28-29
9
2
5
6
3
1
0
0
12
13
14
10
11
8
9
15
5
6
7
2
3
0
1
4
0
1
7
8
5
6
9
10
2
3
0
1
4
11
Radio control configured as START E.
Radio control configured as Start I.
Radio control configured as Open.
Radio control configured as Close
Radio control configured as ped
Radio control configured as STOp
Radio control configured as AUx0 **
Radio control configured as AUx1 **
Radio control configured as AUx2 **
Radio control configured as AUx3 **
Radio control configured as ExpO1 **
Radio control configured as ExpO2 **
Output configured as monostable Radio Channel.
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light
Output configured as Alarm
Output configured as Flashing light
Output configured as Latch
Output configured as Magnetic lock
Output configured as Maintenance
Output configured as Flashing Light and Maintenance.
Not used
Not used
Output configured as gate Status
Output configured as Bistable Radio Channel
Output configured as timed Radio Channel
Output configured as 12V solenoid latch.
Output configured as 12V magnetic lock.
Fixed code 0
0
1
Receiver is configured for operation in rolling-code mode.
Fixed-Code Clones are not accepted.
Receiver is configured for operation in fixed-code mode.
Fixed-Code Clones are accepted.
46 - RIgEL 6
INSTALLATION MANUAL
Logic
Protection level
SERIAL MODE
ADDRESS chrono
EXPI1
Definition
Setting the protection level
Serial mode
(Identifies how board is configured in a BFT network connection).
Default
Cross out setting used
0
0
1
2
3
4
0
Optional extras
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been memorized in standard mode via the radio menu.
- press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters by repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to the receiver’s memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver’s memory.
E - The board’s parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board’s parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMpORTANT: This high level of security stops unwanted clones from gaining access and also stops radio interference, if any.
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
0
1 Standard MASTER: board sends activation commands (START, OpEN, CLOSE, pED, STOp) to other boards.
Address
Time bands
Configuration of
EXPI1 input on input-output expansion board.
1-2
0
0
1
[ ___ ]
8
9
10
6
7
4
5
2
3
0
1
0
1
2
11
12
13
14
15
16
17
18
Identifies board address from 0 to119 in a local BFT network connection.
(see U-LINK OpTIONAL MODULES section)
Logic not enabled
Activates the time bands configured as timer
Activates the time bands configured as pedestrian timer
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as ped command.
Input configured as Timer command.
Input configured as Timer pedestrian command.
Input configured as phot (photocell) safety.
Input configured as phot op safety (photocell active during opening only).
Input configured as phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Input configured as safety Bar Op, safety edge with inversion active only while opening, if while closing the movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the movement stops.
Input configured as phot test safety, tested photocell. Input 3 (ExpI2) on input/output expansion board is switched automatically to safety device test input, ExpFAULT1.
Input configured as phot op test safety, tested photocell active only while opening. Input 3 (ExpI2) on input/ output expansion board is switched automatically to safety device test input, ExpFAULT1
Input configured as phot cl test safety, tested photocell active only while closing. Input 3 (ExpI2) on input/ output expansion board is switched automatically to safety device test input, ExpFAULT1
Input configured as Bar safety, tested safety edge. Input 3 (ExpI2) on input/output expansion board is switched automatically to safety device test input, ExpFAULT1.
Input configured as safety Bar Op test, safety edge with inversion active only while opening, if while closing the movement stops. Input 3 (ExpI2) on input/output expansion board is switched automatically to safety device test input, ExpFAULT1.
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while opening the movement stops. Input 3 (ExpI2) on input/output expansion board is switched automatically to safety device test input, ExpFAULT1.
RIgEL 6 - 47
INSTALLATION MANUAL
Logic
EXPI2
EXPO1
EXPO2
Definition
Configuration of
EXPI2 input on input-output expansion board.
1-3
Configuration of
EXPO2 output on input-output expansion board
4-5
Configuration of
EXPO2 output on input-output expansion board
6-7
TRAFFIC LIGHT
PREFLASHING
Traffic light preflashing
TRAFFIC LIGHT
RED LAMP Steadily lit red light
ALWAYS ON
*
Only active on FW > 1.12
Default
0
11
11
0
10
11
8
9
6
7
4
5
12
13
14
15
0
2
3
0
1
1
Cross out setting used
6
7
4
5
2
3
0
1
8
9
10
11
12
Optional extras
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as ped command.
Input configured as Timer command.
Input configured as Timer pedestrian command.
Input configured as phot (photocell) safety.
Input configured as phot op safety (photocell active during opening only).
Input configured as phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Input configured as safety Bar Op, safety edge with inversion active only while opening, if while closing the movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the movement stops.
Output configured as monostable Radio Channel.
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light.
Output configured as Alarm.
Output configured as Flashing light.
Output configured as Latch.
Output configured as Magnetic lock.
Output configured as Maintenance.
Output configured as Flashing Light and Maintenance.
Output configured as Traffic Light control with TLB board.
Not used
Output configured as gate Status
Output configured as Bistable Radio Channel
Output configured as timed Radio Channel pre-flashing switched off.
Red lights flash, for 3 seconds, at start of operation.
0 Red lights off when gate closed.
0
1 Red lights on when gate closed.
Radio channel control configuration
CH logic= 0 - Control configured as Start E. Operation according to STEP-BY-STEP MOV . logic. External start for traffic light control.
CH logic= 1 - Control configured as Start I. Operation according to STEP-BY-STEP MOV . logic. Internal start for traffic light control.
CH logic= 2 - Control configured as Open.
The command causes the leaves to open.
CH logic= 3 - Control configured as Closed.
The command causes the leaves to close.
CH logic= 4 - Control configured as ped.
The command causes the leaf to open to the pedestrian (partial) opening position. Operation according to STEP-BY-STEP . logic
Logica CH= 5- Control configured as STOp.
The command performs a STOp
CH logic= 6 - Control configured as AUx0. (**)
The control activates the AUx0 output
CH logic= 7 - Control configured as AUx1. (**)
The control activates the AUx1 output
CH logic= 8 -Control configured as AUx2. (**)
The control activates the AUx2 output
CH logic= 9 - Control configured as AUx3. (**)
The control activates the AUx3 output
CH logic= 10 - Control configured as ExpO1. (**)
The control activates the ExpO1 output
CH logic= 11 - Control configured as ExpO2. (**)
The control activates the ExpO2 output
(**) Active only if the output is configured as Monostable Radio Channel, Courtesy Light, Zone Light, Stair Light, Bistable Radio Channel or Timed Radio Channel.
48 - RIgEL 6
INSTALLATION MANUAL
TABLE “C” – RADIO MENU ( RADIO )
Logic add 1ch
Description
Add 1ch Key associates the desired key with the 1nd radio channel command. add 2ch add 3ch add 4ch erase 64
Add 2ch Key associates the desired key with the 2nd radio channel command.
Add 3ch Key associates the desired key with the 3nd radio channel command.
Add 4ch Key associates the desired key with the 4nd radio channel command.
Erase List
WARNING! Erases all memorized transmitters from the receiver’s memory.
erase 1
Eliminates individual radio control
Removes a radio control (if clone or replay is disabled) To select the radio control to be deleted, enter the position or press a button on the radio control to be deleted (the position is displayed)
Read receiver code
Displays receiver code required for cloning transmitters.
RIgEL 6 - 49
ITALY
Download
Advertisement
Key features
Control of one or two motors
Safety features
Customizable settings
Integration with sensors
Easy programming
Detailed installation instructions
Frequently asked questions
RIGEL 6 controls one or two motors for automated gates or doors.
RIGEL 6 includes safety features such as photocells, safety edges, and a manual release system. It also has a built-in safety logic that prevents the gate or door from closing if there is an obstacle in the way.
The RIGEL 6 control unit can be programmed using the on-board display and buttons.
RIGEL 6 can be used with a variety of sensors, including photocells, safety edges, and pressure sensors.