Hirschmann BAT-C Industrial Wireless LAN Client Reference Manual
Advertisement
Advertisement
CLI-Reference Industrial Wireless LAN Client BAT-C
BAT-C Release 03 05/2016 Technical Support https://hirschmann-support.belden.eu.com
The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken to mean that these names may be considered as free in the sense of the trademark and trade name protection law and hence that they may be freely used by anyone. © 2016 Hirschmann Automation and Control GmbH Manuals and software are protected by copyright. All rights reserved. The copying, reproduction, translation, conversion into any electronic medium or machine scannable form is not permitted, either in whole or in part. An exception is the preparation of a backup copy of the software for your own use. For devices with embedded software, the end-user license agreement on the enclosed CD applies. The performance features described here are binding only if they have been expressly agreed when the contract was made. This document was produced by Hirschmann Automation and Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right to change the contents of this document without prior notice. Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document. Hirschmann can accept no responsibility for damages, resulting from the use of the network components or the associated operating software. In addition, we refer to the conditions of use specified in the license contract. You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com). Printed in Germany Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany Tel.: +49 1805 141538 2 BAT-C Release 03 05/2016
Contents
ABOUT THIS MANUAL
1 AT COMMAND SYNTAX
Command Line Format Limitations Data Types
2 STANDARD AT COMMANDS
AT Attention Command AT* List Available Commands
AT&F Restore to Factory Settings AT&F0 Restore to Factory Settings
ATS3 Command Line Termination Character
ATS4 Response Formatting Character
ATS5 Response Formatting Character
ATS General Settings S Register Manipulation
3 LINK LAYER COMMANDS
AT*AGFP Encryption/Authentication Key
AT*AGFPWI Write Encryption/Authentication Key (with Index)
AT*AGAFP Active Encryption/Authentication Key
AT*AGCFP Certificate Fingerprint
BAT-C Release 03 05/2016
6
26
9
7
3
AT*AGRTE Data Rate and Link Adaptation
4 NETWORK LAYER COMMANDS
5 DATA MODE COMMANDS
AT*ADC Connect AT*ADCP Connect to BSSID
AT*ADCPN Connect to name (SSID)
AT*ADRDRP Read Default Remote Peer
AT*ADWDRP Write Remote Peer Information
AT*ADLNK Read WLAN link status
6 INFORMATIONAL COMMANDS
AT*AILBA Read Local MAC Address
7 MISCELLANEOUS COMMANDS
AT*AMLO Log Out AT*AMGD General Data
AT*AMESS Event and Status Subscriber
AT*AMSMF SMART Mode (Button) functionality
AT*AMSMFL SMART Mode Function List
AT*AMSSS SNMP Sys Services AT*AMSBN SNMP Basic Name
AT*AMSBD SNMP Basic Descriptor
4
56
58
47
43
BAT-C Release 03 05/2016
AT*AMSWC SNMP Write Community (Private Community) AT*AMSEID SNMP Enterprise ID
AT*AMEO Set External Digital Output AT*AMSTAT Read Current Status
AT*AMWID Wireless interface disable
8 EVENTS
*ADCPO Connection Up *ADCCO Connection Closed
*AMDST Digital Signal Transition *AMRSS Low RSSI Warning
A FURTHER SUPPORT
83
85
BAT-C Release 03 05/2016 5
About this manual
The following manuals are available as PDF files on the CD-ROM supplied: ► User Manual Configuration and Administration ► Reference Manual ► User Manual Installation ■
Related Documents
BAT-C User Manual Configuration and Administration
. This is a quick setup guide to be able to setup the BAT-C for the simplest out-of-the-box applications.
BAT-C User Manual Installation
. This is a detailed specification or reference for all of the supported AT commands. 6 BAT-C Release 03 05/2016
1 AT command syntax
1.1 Command Line Format
Each command line sent from the DTE (data terminal equipment) to the DCE (data communications equipment) consists of a prefix, body, and terminator. As prefix for the BAT C AT commands, only "AT" (ASCII 65, 84) and "at" (ASCII 97, 116) can be used. There is no distinction between upper and lower case characters. The body is a string of characters in the range ASCII 032-255. Control characters other than
1.2 Limitations
When a AT command is issued with the store parameter set to 1, the previous values will be stored as well, regardless of whether the previous commands where issued with the store parameter set to 1 or not.
1.3 Data Types
The definition of each command specifies the data types used for values associated with the command. There are four different data types: ► ► ► ► ► String Octet String Integer IP_Addr MAC_Addr BAT-C Release 03 05/2016 7
The follow paragraph describes the Data Type listed above: ►
String
A string consists of a sequence of displayable characters from the ISO 8859-1 (8-bit ASCII) character set, except for characters "\", """ and characters below 32 (space). A string constant shall be delimited by two double-quote (""") characters, e.g. "Donald Duck". Use the "\" character as an escape character to insert raw bytes in a string. If the double-quote character (""") is to be used within a string, e.g. "My friend "Bono" is a singer", they have to be represented as "\22". If the back-slash character ("\") is to be used within a string constant, it has to be represented as "\5C". An empty string is represented by two adjacent delimiters, "".
►
Octet String
An octet string shall consist of an even number of hexadecimal values. Valid values are 0-9, 'a'-'f' and 'A'-'F'. ►
Integer
An integer value consists of a sequence of characters all in the range {0..9}. An integer can also be represented by as hexadecimal string, e.g. 15 can be written as "0x0000000F", excluding the double-quote characters. ►
IP_Addr
A valid IP address consists of four integer values separated by dots. Valid range of each integer value is {0..255}. An example IP address is "192.168.0.1", excluding the double quote characters. ►
MAC_Addr
A MAC consists of a sequence of six values, expressed in two-digit hexadecimal, in sequence. Group the hexadecimal values together without delimiters. An example MAC address is "00A0F7101C08", excluding the double-quote characters. The MAC address is an Octet String with a fixed length of 12. 8 BAT-C Release 03 05/2016
2 Standard AT Commands
2.1 AT Attention Command
Syntax Description
AT
Responses
Description
This response indicates a successful execution of the write command.
2.2 AT* List Available Commands
Syntax Description
AT*
Responses
Lists the supported AT commands
Description
2.3 AT&F Restore to Factory Settings
Syntax Description
AT&F
Responses Description
2.4 AT&F0 Restore to Factory Settings
Syntax Description
AT&F0
Responses Description
2.5 ATE Echo Off
Syntax
ATE
Description
Use this command to configure the Ethernet Port Adapter to Echo the incoming characters.
Responses
Description
This response indicates a successful execution of the write command.
2.6 ATE Echo On/Off
Syntax
ATE
Description
Use this command to configure the Ethernet Port Adapter to Echo the incoming characters. Use this command to read the current Echo setting. ATE?
Input and Response Parameters
echo_on
Type Description
integer 0 = The echo characters function is off during command state and online command state. 1 = Unit echoes characters during command state and online command state. BAT-C Release 03 05/2016 11
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command.
2.7 ATQ Result Codes On/Off
Syntax Description
ATQ
Input and Response Parameters
result_off
Type Description
integer 0 = Unit transmits result codes. 1 = Result codes are suppressed. 12 BAT-C Release 03 05/2016
Responses
Description
The device displays the current parameter setting followed by ”OK“, after entering a successful read command.. This response indicates a successful execution of the write command.
2.8 ATS2 Escape Character
Syntax Description
ATS2=
Input and Response Parameters
esc_char
Type Description
integer “esc_char” is the ASCII value of the new escape character, i.e. 47 equals '/'. The default character is '/'.
Note:
The escape sequence will be "///". Therefore, enter the character three times.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command.
2.9 ATS3 Command Line Termination Character
Syntax Description
ATS3=
Input and Response Parameters Type Description
line_term
Responses
integer 0...127 (13, CR is default)
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command.
2.10 ATS4 Response Formatting Character
Syntax Description
ATS4=
Input and Response Parameters Type Description
term
Responses
integer 0...127 (10, LF is default)
Description
2.11 ATS5 Response Formatting Character
Syntax Description
ATS5=
Input and Response Parameters
backspace
Responses
Type Description
integer 0...127 (8, BS is default)
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command.
2.12 ATS General Settings S Register Manipulation
Syntax Description
ATS
Input and Response Parameters
1100 Use this command to read from a general settings S register.
Type Description
register value integer Any of the registers described below. integer -2147483648...2147483647 or 0x00000000...0xFFFFFFFF. Listed below are valid values for each register.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command.
Register Roaming registers Description
RSSI thresholds Use this by the smart LEDs deciding how to indicate the current RSSI. Default value is 0xC9BFB5AB, giving the following limits: >85 dBm -> 1 LED >75 dBm -> 2 LEDs >65 dBm -> 3 LEDs >55 dBm -> 4 LEDs BAT-C Release 03 05/2016 17
Responses
1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1119
Miscellaneous
1200 1201 1202 1203 18
Description
Reserved Reserved Reserved Reserved Roaming scheme 0: Connect to name, see connect to name scheme (default) 1: Connect to next. This will simply connect to the next device configured with AT*ADWRL Write Roaming List 2-31: Reserved Reserved Reserved Reserved Reserved Reserved Roaming RSSI diff threshold (default 10) When the difference between the connected AP RSSI and the RSSI from the best AP from background scan exceeds this threshold a roaming handover is done. Reserved Use this register to configure the time in seconds before the LEDs turn off. Entering “0” will disable the feature. Reserved Reserved Disable Link configuration if broadcast BAT-C Release 03 05/2016
1208 1209 1210 1211 1212 1213 1214
Responses
1204 1205 1206 1207 BAT-C Release 03 05/2016
Description
Reserved Reserved Reserved Event Subscriber Protocol The device sends events according to this value. 0: disable (default) 1: Messages sent by AT over TCP 2: Messages sent by AT over Layer-2, mac_address must be specified using AT*AMESS 3: Syslog, destination IP address must be specified using AT*AMESS 4 - 255: reserved Event Subscriber Port / Ethernet type Wireless Interface Disable 0 = Enable Wireless Interface (default) 1 = Disable Bridge Cache Timeout Time in seconds before MAC address cache table in the bridge throws away an entry. Bit mask representing SMART LED Mode when finishing smart mode Bit 0: RSSI Bit 1: RESERVED Bit 3-31: RESERVED Smart LED Update timeout in seconds Activate User Management 0: disable 1: enable Smart mode button push functionality 0: Disconnect/connect 1: Toggle ALL LEDs 2: Reset 19
1219 1220
Profinet
1900 1901 20
Responses
1215 1216 1217 1218
Description
Smart mode button hold functionality 0: Disconnect/connect 1: Toggle ALL LEDs 2: Reset External trigger push functionality 0: Disconnect/connect 1: Toggle ALL LEDs 2: Reset External trigger hold functionality 0: Disconnect/connect 1: Toggle ALL LEDs 2: Reset Write diagnose mode bitmask. Default value is 0x00000001. This function sends the following events when the bit is set: Bit 0: *ADCPO - Connection up *ADCCO - Connection down *AMDST - Digital signal transition *AMRSS - RSSI value below -70dBm Bit 1: *AGRSS - RSSI periodically sent with interval set by ATS register 1219 *AGCH - Used WLAN channel, sent upon connection setup Bit 2: *AGSCAN - Background scan result RSSI poll interval in milliseconds Default value is 1000 ms. Maximum time to wait for first push on SMART button Default value is 5000 ms. Reserved Reserved BAT-C Release 03 05/2016
3005 3006 3007 3008 3009 3010 3001 3002 3003 3004
Responses
1902 1903 1904
WLAN
3000 BAT-C Release 03 05/2016
Description
Profinet prioritization: 0: Disable (default) 1: Enable Reserved Ethernet type to prioritize, default 0x8892 WLAN preamble 0 = Long preamble 1 = Short preamble (default) Reserved WLAN minimum scan time in milliseconds on each channel 0...65535 (default 50) WLAN maximum scan time in milliseconds on each channel 0...65535 (default 200) WLAN scan type 0 = Active scan (default) 1 = Passive scan Reserved Averaging depth for the RSSI trigger 1...16 (default 4, 1 means no depth) WLAN lower lost beacon value to trigger a rescan. The maximum number of lost beacons before a rescan happens. 1...32 (default 30) Averaging depth for the lost beacon trigger 1...32 (default 32) Reserved Reserved 21
Responses
3011 3012 3013 3014 3015 3016 3017 3018 3019 22
Description
Beacon Period of the BSS Descriptor of the ESS to Join or Start a network in IBSS. Value in milliseconds 100 (default 100) Use this register to configure the time limit, in units of beacon intervals, after which termination of the Join procedure occurs. 1...100 (default 10) Reserved Max power (use AT*AMMP) Reserved Data Rate (use AT*AGRTE) Link Adaption (use AT*AGRTE) 0: Disable 1: Enable Power save 0: Disable 1: Enable Regulatory domain 1: World Domain (default) (1...11) 2.4GHz 2: FCC (1...11) 2.4GHz 3: ETSI (1...13) 2.4GHz 4: TELEC (1...14) 2.4GHz 10: U-NII-1 (36, 40, 44, 48) 5GHz 20: U-NII-2 (52, 56, 60, 64) 5 GHz 40: U-NII-2 extended (100, 104, 108, 116, 120, 124, 128, 132, 136, 140 ) 5 GHz 80: U-NII-3 Upper (149, 153, 157, 161) 5 GHz The regulatory domain values can be added if multiple options are required. For example, 21 (20 + 1) represents option 1 and option 20 and signifies World Domain and U-NII-1. Note: After changing the regulatory domain, verify that the channel list is updated according to your preferences as well. (AT*AGCL) BAT-C Release 03 05/2016
Responses
3020 3021 3022 3023 3024 3025 3026 3027
Description
DTIM Enable 0: Disable 1: Enable (default) QoS Enable 0: Disable 1: Enable (default) Reserved Reserved Reserved Reserved Reserved Background scanning idle timeout (default 1000 ms) When there has been no data activity for the last 'idle timeout' ms, the background scan starts. 3028 3029 4000 BAT-C Release 03 05/2016 Background scanning interval Time between background scans(default 5000 ms) Background scanning scheme Configure when to initiate background scanning with this register. A prerequisite for this is that the RSSI level is below Trigger Scan RSSI (ATS4012). 0: Always in intervals of ATS3028 ms 1: When idle, the idle time is checked every ATS3028 ms. Reserved, do not modify 23
4004 4005 4006 4007 4008 4009 4010
Responses
4001 4002 4003 4011 24
Description
Reserved, do not modify. Reserved, do not modify. WPA key input mode Controls how the WPA key is parsed and interpreted. 0 = Auto (default) 1 = ASCII 2 = Hexadecimal Auto mode will try to determine if it the input is an ASCII key or a HEX key by looking at the contents. Reserved Reserved Reserved Reserved, do not modify Ad-hoc timeout Time before a single unit in an ad-hoc network tries a rescan to find an existing network. Value in milliseconds 0 = disabled 0...2147483647 (default 6000) Delayed association This value sets the time to wait before initiating an association attempt. Value in milliseconds 0 = no delay 0...2147483647 (default 0) LLDP send interval The module sends, per default, information in LLDP frames with its current setup and those of its peers. Another use for this parameter is to stay alive on access points that do not properly wake the module before a disassociation. Value in seconds 0 = Do not send. 0...2147483 (default 60) Reserved BAT-C Release 03 05/2016
5001 5002 5003
Responses
4012 4013 4014
Networking
5000
Description
Trigger Scan RSSI Defines at what RSSI level to initiate a background scan to search for a better connection. Normally when the Slave is lost, the Master assumes this task. The Master searches for a better connection when RSSI exceeds this value. LLDP hold multiplier This value multiplied with LLDP interval equals the total time an LLDP update is valid. 1...10 (default 4) Enable/disable adaptive RSSI threshold. 0 = Disable (default) 1 = Enable Turn on/off TCP keep-alive packets It is important to understand that sending frequent keep-alive packets usually isn't a good solution to detect dropped connections. Perform dead links detection on a higher level, i.e. in the user application protocol. There is a lot of information available on the subject on the web. 0 = TCP keep-alive packets turned off (default)1 = TCP keep alive packets turned on This is the time in milliseconds for a TCP connection to be idle before sending a keep-alive packet. 0...2147483647 (default 7200000 = 2 hours) This is the time in milliseconds between keep-alive packets after losing a keep-alive packet. 0...2147483647 (default 75000 = 75 seconds) This is the number of lost keep-alive packets to wait before resetting a TCP connection. 1...255 (default 9) BAT-C Release 03 05/2016 25
3 Link Layer Commands
3.1 AT*AGAM Authentication Mode
Syntax Description
AT*AGAM=
Input and Response Parameters Type Value
amode store_in_startup_database Integer 0 = Open (default) 1 = Shared secret 2 = WPA/WPA2 PSK 3 = LEAP 4 = PEAP 5 = Reserved Integer 0: The setting will be valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command. 26 BAT-C Release 03 05/2016
3.2 AT*AGEM Encryption Mode
Syntax
AT*AGEM?
Description
AT*AGEM=
Input and Response Parameters Type Value
emode Integer 0 = None (default) 1 = WEP64 2 = WEP128 3 = TKIP 4 = AES/CCMP store_in_startup_database Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses Description
3.3 AT*AGSM Security Mode
Syntax Description
AT*AGSM=
Input and Response Parameters Type Value
smode store_in_startup_database Integer 0 = No security (default) (AM=0,EM=0) 1 = Shared-WEP64 (AM=1,EM=1) 2 = Shared-WEP128 (AM=1,EM=2) 3 = WPA-PSK-TKIP (AM=2,EM=3) 4 = WPA2-PSK-AES/CCMP (AM=2,EM=4) 5 = LEAP-WPA2 (AM=3,EM=4) 6 = LEAP-WEP128 (AM=3,EM=2) Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command. 28 BAT-C Release 03 05/2016
3.4 AT*AGOM Operational Mode
Syntax Description
AT*AGOM=
Input and Response Parameters Type Value
omode store_in_startup_database Integer 1 = Managed (infrastructure) (default) 2 = Ad-Hoc Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command. BAT-C Release 03 05/2016 29
3.5 AT*AGFP Encryption/Authentication Key
Syntax Description
AT*AGFP=
Input Parameters Type Value
key store_in_startup_database String Use any string value for this setting. Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
This response indicates a successful execution of the write command.
3.6 AT*AGFPWI Write Encryption/Authentication Key (with Index)
Syntax Description
AT*AGFPWI=
Input Parameters
Use this command to write the encryption/authentication key.
Type Value
keyindex Integer The valid integers are 1...4. key store_in_startup_database String Use any string value for this setting. Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
This response indicates a successful execution of the write command.
3.7 AT*AGAFP Active Encryption/Authentication Key
Syntax Description
AT*AGAFP=
Input and Response Parameters Type Value
keyindex store_in_startup_database Integer Valid integers for this function are 1...4 (1 default). Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command. 32 BAT-C Release 03 05/2016
3.8 AT*AGUN Username
Syntax Description
AT*AGUN=
Input and Response Parameters Type Value
username store_in_startup_database String Use this name for identification on authentication servers. See AT*AGAM Authentication Mode. Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command. BAT-C Release 03 05/2016 33
3.9 AT*AGDN Domain name
Syntax Description
AT*AGDN=
Input and Response Parameters Type Value
domain store_in_startup_database String This is the domain to use with authentication servers. See AT*AGAM Authentication Mode. Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command. 34 BAT-C Release 03 05/2016
3.10 AT*AGCFP Certificate Fingerprint
Syntax Description
AT*AGCFP=
Input and Response Parameters Type Value
fingerprint store_in_startup_database Octet String This is a 20 bytes octet string representing the fingerprint. (quotes (") shall not be used) Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses Description
3.11 AT*AGSSID Network Name (SSID)
Syntax Description
AT*AGSSID=
Input and Response Parameters Type Value
ssid store_in_startup_database String Use any string value, max length 32 bytes. Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command.
3.12 AT*AGRSS RSSI Value
Syntax Description
AT*AGRSS? Use this command to read the current RSSI value of the connection. If the module is not connected it returns an ERROR.
Response Parameter Type Value
rssi Integer This is the RSSI value. -128...10 where value is dBm value Use this command after the device establishes a connection, otherwise, the response to this read command is an error message.
Responses
Description
This response indicates a successful execution of the write command.
3.13 AT*AGCH Channel Number
Syntax
AT*AGCH?
Description
AT*AGCH=
Input and Response Parameters Type Value
ch_no Integer 0 = Auto (default), select from defined channel list. > 0 = Channel to use. Available channels depending on regulatory domain setting. store_in_startup_database Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command.
3.14 AT*AGCL Channel List
Syntax
AT*AGCL=
Description
Use this command to write the channel number to use. Use this command to read the current channel number in use.
Input and Response Parameters
ch#
Type Value
Integer Write the channel list to use. This list also specifies the scan order. The number of channels to specify is dependent on the regulatory domain set. See command AMRD for details about regulatory domains and below for channel list lengths. If you don´t want to use all positions, pad list with zeros. Channel list length for the regulatory domains: World = 11 FCC = 11 ETSI = 13 U-NII band 1 = 4 U-NII band 2 = 4 U-NII band 2 extended = 11 U-NII band 3 Upper = 4 Example 1: If regulatory domain is set to World + U-NII band 1 + 2, then the number of channels to specify is 11 + 4 + 4 = 19. AT*AGCL:6,1,11,2,7,4,9,3,8,5,10,36,40,44,48,52,56,60,64,1 Example 2: To use only channel 1,6 and 11 in regulatory domain ‘World’. AT*AGCL=1,6,11,0,0,0,0,0,0,0,0,0,0,0,1 store_in_startup_database Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database. BAT-C Release 03 05/2016 39
Responses Description
3.15 AT*AGSCAN
Syntax
AT*AGSCAN? AT*AGSCAN=
Input and Response Parameters
bssid op_mode
Type
ssid channel rssi encryption
Description
Use this command to SCAN for available networks. The command will return 0...48 networks in the immediate surroundings, then return OK. Use this command to SCAN the available networks with specific a SSID on a specified channel.
Value
MAC_Addr MAC address of the access point Integer 1 = Infrastructure 2 = Ad-hoc String Integer Integer SSID name of network Channel the network uses Signal strength value for the network Integer 0 = No encryption 1 = WEP 2 = WPA 3 = WPA2/RSN 40 BAT-C Release 03 05/2016
Input and Response Parameters
information_element
Type
String
Value
This is a Hexadecimal string with the information element for WPA and RSN networks. The string is unavailable for WEP networks or networks without encryption.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates an unsuccessful execution of the write command.
3.16 AT*AGRTE Data Rate and Link Adaptation
Syntax Description
AT*AGRTE=
Input and Response Parameters
data_rate link_adaptation store_in_startup_database
Responses
Type Value
Integer Integer Integer 1 = 1Mbit (only 2.4GHz) 2 = 2Mbit (only 2.4GHz) 3 = 5.5Mbit (only 2.4GHz) 4 = 6Mbit 5 = 9Mbit 6 = 11Mbit (only 2.4GHz) 7 = 12Mbit 8 = 18Mbit 9 = 24Mbit (default) 10 = 36Mbit 11 = 48Mbit 12 = 54Mbit 13 = 6.5Mbit 14 = 13Mbit 15 = 19.5Mbit 16 = 26Mbit 17 = 39Mbit 18 = 52Mbit 19 = 58.5Mbit 0 = Link adaptation off. The device uses the configured data_rate. 1 = Link adaptation on. The data_rate of the device adjusts automatically depending on the operation environment. 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command. 42 BAT-C Release 03 05/2016
4 Network Layer Commands
4.1 AT*ANIP IP Settings
Syntax Description
AT*ANIP=
Input and Response Parameters
ip_addr netmask gw
Type Value
IP_Addr IP address for the device (default 172.23.56.99) IP_Addr Netmask for the device (default 255.255.255.0) IP_Addr The IP address of the gateway (default 172.23.56.99) store_in_startup_database integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command.
4.2 AT*ANDHCP DCHP Activation
Syntax Description
AT*ANDHCP=
Input and Response Parameters Type Value
dhcp_mode integer 0: Static, enter a static IP address (default) 1: DHCP Client, acquire an IP address using DHCP 2: DHCP Server, use a static IP address and act as DHCP server 3: Auto IP, The BAT-C will be assigned a private IP address with a prefix of 169.254/16. 4: DHCP Relay, use a static IP address, and act as DHCP relay. 5: DHCP Client + DHCP Relay, acquire an IP address using DHCP, then act as DHCP relay (default) store_in_startup_database integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command.
4.3 AT*ANHN Hostname
Syntax Description
AT*ANHN=
Input and Response Parameters
hostname
Type Value
string Use any string (default: "BAT-C") store_in_startup_database integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
4.4 AT*ANDNS DNS Settings
Syntax
AT*ANDNS?
Description
AT*ANDNS=
Input and Response Parameters Type Value
dns1 dns2 IP_Addr This is the Primary DNS server. If DNS is not used, set this parameter to 0.0.0.0 (default 0.0.0.0). IP_Addr This is the Secondary DNS server. If DNS is not used or if one server is used, set this parameter to 0.0.0.0 (default 0.0.0.0). store_in_startup_database integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
5 Data Mode Commands
5.1 AT*ADC Connect
Syntax Description
AT*ADC
Responses Description
5.2 AT*ADCP Connect to BSSID
Syntax Description
AT*ADCP=
Input Parameters Type Value
BSSID network_type wlan_channel ssid Mac_Addr This is the BSSID of the desired AP. Integer Integer String 1 = Managed mode 0 = Auto (default) 1...11, 1...13 or 14 depending on regulatory domain setting for 2.4GHz. 36, 40, 44, 48 for 5GHz. This is the SSID of the desired AP. BAT-C Release 03 05/2016 47
5.3 AT*ADCPN Connect to name (SSID)
Syntax Description
AT*ADCPN=
Input and Response Parameters Type Value
SSID network_type wlan_channel Reserved connection_handle
Responses
string This is the SSID of the desired AP or Ad Hoc unit. Integer 1 = Managed mode 2 = Ad-Hoc Integer 0 = Auto (default) 1 …11, 1…13 or 14 depending on regulatory domain setting for 2.4GHz 36, 40, 44, 48 for 5GHz. Integer This parameter is for future use. Integer 1=closes the current connection
Description
5.4 AT*ADCC Close Connection
Syntax Description
AT*ADCC=
Input Parameters Type Value
connection_handle
Responses
Description
This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command. BAT-C Release 03 05/2016 49
5.5 AT*ADRDRP Read Default Remote Peer
Syntax Description
AT*ADRDRP=
Input and Response Parameters Type
Use this command to read the current default peer.
Value
peer_id address conn_scheme update_on_incoming name
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates an unsuccessful execution of the write command. 50 BAT-C Release 03 05/2016
5.6 AT*ADWDRP Write Remote Peer Information
Syntax Description
AT*ADWDRP=
Input Parameters Type
Use this command to write information for a remote peer.
Value
peer_id address conn_scheme reserved name Integer This is any value between 0 and the response from AT*ADMRP – 1. String Address to the service on the remote peer. In the form of,
Responses Description
5.7 AT*ADRL Roaming List
Syntax Description
AT*ADRL? Use this command to read the current list of Access Points used for roaming.
Response Parameters Type Value
index bssid store_in_startup_database integer This is the position in the roaming list. Mac_Addr This is the BSSID of the Access Point. integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device sends this response for every AP in the list.
5.8 AT*ADRRL Read Roaming List
Syntax Description
AT*ADRRL=
Input and Response Parameters Type Value
index bssid channel
Responses
integer integer This is the position in the roaming list. Mac_Addr This is the BSSID of the Access Point. This is the channel of the AP.
Description
5.9 AT*ADWRL Write Roaming List
Syntax Description
AT*ADWRL=
Input Parameters Type
This command writes the BSSID of the AP in the roaming list.
Value
index bssid channel store_in_startup_database integer integer This is the position in the roaming list. Mac_Addr This is the BSSID of the Access Point. integer This is the channel of the AP. 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses Description
5.10 AT*ADLNK Read WLAN link status
Syntax Description
AT*ADLNK?
Response Parameters
Use this command to read the current WLAN link status.
Type Value
link_status integer 0: Not associated 1: Associated Mac_Addr BSSID of the WLAN network or N/A if not associated. bssid
Responses Description
6 Informational Commands
6.1 AT*AILBA Read Local MAC Address
Syntax Description
AT*AILBA?
Response Parameters
mac_addr
Responses
This command reads the MAC Address of the local device.
Type
Mac_Addr
Value
This is the Local MAC address.
Description
6.2 AT*AILVI Local version
Syntax Description
AT*AILVI?
Response Parameters
manufacturer
Type Value
String This is the Ethernet port adapter manufacturer, i.e. "Hirschmann". spa_sw_version String This is the Ethernet port adapter software version, i.e. "2.3.2 [11:32:15,May 14 2012]". wlan_driver_version wlan_fw_version String This is the WLAN host driver version, i.e. "2.12.1". String This is the WLAN firmware version, i.e. "3.2.8.5". wlan_hw_manufacturer String This is the WLAN hardware manufacturer, example "RPS".
Responses Description
7 Miscellaneous Commands
7.1 AT*AMLI Log in
Syntax Description
AT*AMLI=
Input Parameters Type Value
password
Responses
String This is a null terminated string of up to 15 bytes.
Description
This response indicates a successful execution of the write command.
7.2 AT*AMLO Log Out
Syntax Description
AT*AMLO=
Input Parameters Type
Use this command to Log out from the AT command interface.
Value
log_out
Responses
Integer 1= log out
Description
This response indicates a successful execution of the write command.
7.3 AT*AMGD General Data
Syntax Description
AT*AMGD=
Input and Response Parameters Type Value
String Represents the data to store, up to 31 bytes long. data
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. BAT-C Release 03 05/2016 59
Responses
Description
This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command.
7.4 AT*AMMP Max Output Power
Syntax Description
AT*AMMP=
Input and Response Parameters Type Value
max_power store_in_startup_database
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command. 60 BAT-C Release 03 05/2016
7.5 AT*AMWS Watchdog Settings
Syntax Description
AT*AMWS=
Input and Response Parameters
reserved1 Use this command to read the current watchdog settings.
Type Value
inactivity_timeout connect_timeout disconnect_reset reset store_in_startup_database Integer This parameter is for future use. This is a “0” for this parameter. Integer This is the time in seconds before the BAT-C resets if it receives no data on the WLAN interface. 0: Disabled (default value) > 0: Timeout in seconds Integer This is the Max connection time in seconds before the BAT-C resets. 0: Disabled (default value) > 0: Timeout in seconds Integer 0: Disabled (default value) 1: Enabled, the BAT-C will reset on a terminated connection. Integer 1: Reset the unit immediately. Will not store nor return any response. Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database. BAT-C Release 03 05/2016 61
Responses Description
7.6 AT*AMESS Event and Status Subscriber
Syntax Description
AT*AMESS=
Input and Response Parameters Type Value
mac_addr ip_addr port MAC_Addr This is the MAC address of event subscriber. IP_Addr Integer This is the IP address of event subscriber. This is the port number of event subscriber 0: use default Layer-2 events, must be specified 62 BAT-C Release 03 05/2016
Input and Response Parameters
protocol
Type Value
store_in_startup_database Integer integer Manage event transmission using the following values. 0: disable (default) 1: Messages sent by AT over TCP 2: Messages sent by AT over Layer-2 (mac_address must be specified, FFFFFFFFFFFF means that it will be broadcasted) 3: Syslog 4 - 255: reserved 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command.
7.7 AT*AMSMF SMART Mode (Button) functionality
Syntax Description
AT*AMSMF=
Input and Response Parameters
short_mode
Type Value
long_mode store_in_startup_database Integer Manage the “Push” functionality with the following values. 0: Trigger roaming (disconnect/connect) 1: Toggle Leds 2: Soft reset Integer Manage the “Hold” functionality with the following values. 0: Trigger roaming (disconnect/connect) 1: Toggle Leds 2: Soft reset integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
7.8 AT*AMSMFL SMART Mode Function List
Syntax Description
AT*AMSMFL=
Input and Response Parameters Type Value
smart_mode_# store_in_startup_database Integer 0: End Smart mode function list 1 - 15 SMART functionality: 1: Exit Smart mode 2: Reset to factory defaults 3: Reset IP settings to factory defaults 4: Wait for Automatic configuration - Ad-Hoc 5: Initiate Automatic configuration - Ad-Hoc 6: Wait for Automatic configuration - Profinet - Ad-Hoc 7: Initiate Automatic configuration - Profinet - Ad-Hoc 8: Wait for Automatic configuration - Managed mode 9: Initiate Automatic configuration - Managed mode 10: Initiate Automatic configuration - Managed mode - wired 11: Configure Client mode 12: Initiate Automatic configuration - Ad-Hoc - Multipoint 13: Reserved 14: Reserved 15: Enable DHCP server 16 - 255: Reserved Default: 15,2,3,4,5,6,7,8,9,10,11,12 integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database. BAT-C Release 03 05/2016 65
Responses
Description
7.9 AT*AMSSC SNMP Sys Contact
Syntax Description
AT*AMSSC=
Input and Response Parameters Type Value
sys_contact store_in_startup_database String This is a desired string, up to 32 characters. integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses Description
Responses
Description
This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command.
7.10 AT*AMSSL SNMP Sys Location
Syntax Description
AT*AMSSL=
Input and Response Parameters
sys_Location
Type Value
store_in_startup_database String This is a desired string, up to 32 characters. integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
7.11 AT*AMSSS SNMP Sys Services
Syntax Description
AT*AMSSS?
Response Parameters Type Value
sys_services Integer This parameter represents the system services defined by SNMP.
Responses Description
7.12 AT*AMSBN SNMP Basic Name
Syntax Description
Use this command to write the SNMP Basic Name. AT*AMSBN=
Input and Response Parameters
basic_name store_in_startup_database
Type Value
String This is a desired string, up to 32 characters. integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration 68 BAT-C Release 03 05/2016
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command.
7.13 AT*AMSBD SNMP Basic Descriptor
Syntax Description
AT*AMSBD=
Input and Response Parameters Type Value
basic_descriptor String This is a desired string, up to 32 characters. store_in_startup_database integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses Description
Responses
Description
This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command.
7.14 AT*AMSSD SNMP Sys Description
Syntax Description
AT*AMSSD=
Input and Response Parameters Type Value
basic_description store_in_startup_database String This is a desired string, up to 32 characters. integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
7.15 AT*AMSWC SNMP Write Community (Private Community)
Syntax Description
AT*AMSWC=
Input Parameters Type Value
community store_in_startup_database String This is a desired string, up to 12 characters. integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
This response indicates a successful execution of the write command.
7.16 AT*AMSEID SNMP Enterprise ID
Syntax Description
AT*AMSEID?
Response Parameters Type Value
Integer This is an integer representing your company. BAT-C Release 03 05/2016 71
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates an unsuccessful execution of the write command.
7.17 AT*AMTL TCP Listener
Syntax
Description
AT*AMTL=
Input and Response Parameters
enable
Type Value
Integer 0 = Disables TCP Listener 1 = Enables TCP Listener. When enabled, it will always enter at mode at startup Integer TCP port to listen for incoming connections port store_in_startup_database Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses Description
7.18 AT*AMUR UDP Receiver
Syntax
AT*AMUR=
Description
Use this command to enable or disable the UDP Receiver. Use this command to read the current UDP receiver activation status.
Input and Response Parameters
enable
Type Value
port store_in_startup_database Integer 0 = Disables UDP Receiver 1 = Enables UDP Receiver Integer UDP port to listen for incoming packets Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command. BAT-C Release 03 05/2016 73
7.19 AT*AMHL HTTP Listener
Syntax
AT*AMHL=
Description
Use this command to enable or disable the HTTP Listener. Use this command to read the current HTTP Listener status.
Input and Response Parameters
enable
Type Value
port store_in_startup_database
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command. 74 BAT-C Release 03 05/2016
7.20 AT*AMSR SNMP Receiver
Syntax Description
AT*AMSR=
Input and Response Parameters
Use this command to read the current SNMP Receiver status.
Type Value
enable port Integer 0 = Disables SMNP Receiver 1 = Enables SNMP Receiver Integer This is the UDP port to listen for incoming packets. store_in_startup_database Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command. BAT-C Release 03 05/2016 75
7.21 AT*AMLCR Link Config Receiver
Syntax Description
AT*AMLCR=
Input and Response Parameters Type Value
enable Integer 0 = Disables Link Config Receiver 1 = Enables Link Config Receiver Integer Ethernet type that will be passed up the AT parser eth_type store_in_startup_database Integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses
Description
7.22 AT*ACEW Configure Mode
Syntax
AT*ACEW=
Description
Use this command to configure and enter Client mode. Use this command to read the current Wireless LAN MAC address and mode.
Input and Response Parameters Type Value
mac_addr enter mode store_in_startup_database
Responses
Description
The device displays the current parameter setting, followed by “OK“, after entering a successful read command. This response indicates a successful execution of the write command. This response indicates an unsuccessful execution of the write command. BAT-C Release 03 05/2016 77
7.23 AT*AMEO Set External Digital Output
Syntax Description
AT*AMEO=
Input Parameters Type
Use this command to set External digital Output to value.
Value
value integer 0: LOW - Ground (0V DC) 1: HIGH – The voltage will be set to the corresponding value on the power connector, A-coded male M12, pinning number 5 (typical 12-24 V DC).
Responses Description
7.24 AT*AMSTAT Read Current Status
Syntax Description
AT*AMSTAT=
Input and Response Parameters Type Value
level integer 1 = Common 2 = Reserved 3 = WLAN 4 = Reserved 5 = Ethernet 6 = Reserved 7 = Reserved 78 BAT-C Release 03 05/2016
Input and Response Parameters
id uptime wlan_mac_addr wlan_status op_mode ssid bssid data_rate rssi channel eth_mac_addr eth_status ip_addr subnet gateway dhcp_mode dns1 dns2
Type
integer integer MAC_Addr integer integer string MAC_Addr integer integer integer MAC_Addr integer IP_Addr IP_Addr IP_Addr integer IP_Addr IP_Addr
Value
0 = This entry is optional. This is the uptime in seconds. This is the WLAN MAC address. 0 = Not associated 1 = Associated 1 = Managed 2 = Ad-hoc This is the SSID of the AP. This is the BSSID of the AP or associated device. See AT*AGRTE for further details. See AT*AGRSS for further details. This is the Channel. This is the Ethernet MAC address. Lists the Ethernet Link Status 0: Link is down 1: Link is up This is the Static IP address or assigned IP address when using DHCP. This is the Subnet mask. This is the Gateway IP address. This is the DHCP mode, see AT*ANDHCP for further details. This is the Primary DNS server. This is the Secondary DNS server. BAT-C Release 03 05/2016 79
Responses Description
*UPTIME:
7.25 AT*AMWID Wireless interface disable
Syntax
AT*AMWID?
Description
AT*AMWID=
Input and Response Parameters
disable
Type Value
store_in_startup_database integer 0: Wireless interface enabled 1: Wireless interface is disabled integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database.
Responses Description
7.26 AT*AMPSM Profisafe Mode
Syntax
AT*AMPSM=
Description
Use this command to enable ProfiSafe Mode. This command disables the write configuration mode. However, with the ProfiSafe Mode enabled, you are able to read the configuration on the device. To amend the configuration, set the device in configuration mode with “AT*ACEW” or reset to factory defaults with “AT&F0”. Use this command to read the ProfiSafe Mode Status. AT*AMPSM?
Input and Response Parameters
ps_mode
Type Value
store_in_startup_database apply_without_restart integer 0: ProfiSafe Mode disabled 1: ProfiSafe Mode enabled integer 0: The setting is valid for the current power cycle. 1: The Ethernet Port Adapter retains the configuration between power cycles by updating the settings database. integer This entry is optional. 1: The device enters the ProfiSafe Mode directly without a restart when setting this entry to 1. This command disables the write configuration mode immediately after execution.
Responses Description
8 Events
8.1 *ADCPO Connection Up
Event Description
*ADCPO:
Input and Response Parameters
After establishing a connection to a remote device, the BAT-C transmits the event.
Type Value
connection_handle network_type integer integer Identifies the connection. 1: Managed 2: Ad Hoc mac_addr bssid Mac_Addr Local mac address Mac_Addr Bssid of the network we are connected to.
8.2 *ADCCO Connection Closed
Event Description
*ADCCO:
Input and Response Parameters Type Value
connection_handle integer Identifies the connection. BAT-C Release 03 05/2016 83
Input and Response Parameters
reason mac_addr bssid
Type Value
integer 0: Disconnected by command 1: Disconnected by link loss 255: Reason unknown Mac_Addr Local MAC address. Mac_Addr Bssid of the network we were previously connected to.
8.3 *AMDST Digital Signal Transition
Event Description
*AMDST:
Parameters
mac_addr
Type Value
Mac_Addr MAC address of the device.
8.4 *AMRSS Low RSSI Warning
Event
*AMRSS:
Response Parameters Type
mac_addr rssi
Licenses
Description
The RSSI value is below -70 dBm.
Value
Mac_Addr MAC address of the device. Integer RSSI value 84 BAT-C Release 03 05/2016
A Further Support
■
Technical Questions
For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly. You will find the addresses of our partners on the Internet at http://www.hirschmann.com Contact our support at https://hirschmann-support.belden.eu.com You can contact us in the EMEA region at ► ► Tel.: +49 (0)1805 14-1538 E-mail: [email protected] in the America region at ► ► Tel.: +1 (717) 217-2270 E-mail: [email protected] in the Asia-Pacific region at ► ► Tel.: +65 68549860 E-mail: [email protected] ■
Hirschmann Competence Center
The Hirschmann Competence Center is ahead of its competitors: ► ► ► ► Consulting incorporates comprehensive technical advice, from system evaluation through network planning to project planning. Training offers you an introduction to the basics, product briefing and user training with certification. The current training courses to technology and products can be found at http://www.hicomcenter.com Support ranges from the first installation through the standby service to maintenance concepts. With the Hirschmann Competence Center, you have decided against making any compromises. Our client-customized package leaves you free to choose the service components you want to use. Internet: http://www.hicomcenter.com BAT-C Release 03 05/2016 85