Generac 60kW RG06024ANSX Standby Generator Manual

Add to my manuals
2 Pages

advertisement

Generac 60kW RG06024ANSX Standby Generator Manual | Manualzz
4
SH
3
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
B
2.4L
OIL FILL CAP
EITHER SIDE
RIGHT SIDE
OIL FILTER
LEFT SIDE
OIL DRAIN HOSE
RIGHT SIDE
RADIATOR DRAIN HOSE
LEFT SIDE
COOLANT RECOVERY BOTTLE
LEFT SIDE
RADIATOR FILL CAP
ROOF TOP
AIR CLEANER ELEMENT
LEFT SIDE
SPARK PLUGS
LEFT SIDE
MUFFLER
SEE NOTE 11
DRIVE BELT
EITHER SIDE
FAN BELT
SEE NOTE 11
BATTERY
LEFT SIDE
LUBE OIL MAINTAINER
SUPPLY TANK FILL CAP
ROOF TOP
REFERENCE OWNERS MANUAL
FOR PERIODIC REPLACEMENT
PART LISTINGS.
357
[14.0]
REMOVE COVER FOR
ACCESS TO LUBE OIL
MAINTAINER SUPPLY TANK
REFERENCE OWNERS MANUAL
683.3 [26.9]
CENTER OF GRAVITY
167
[6.6]
BATTERY 12V
GROUP 26
NEGATIVE GROUND
P/N: 077483
TOP VIEW
CIRCUIT BREAKER
SEE NOTE 3
EXHAUST MUFFLER
ENCLOSED WITHIN
GENERATOR ENCLOSURE
REV
D
WINDCHILL VERSION
D.1
1
NOTES:
OIL DIP STICK
AIR INTAKE
(BOTH SIDES)
REMOVE COVER
FOR ACCESS TO
RADIATOR FILL CAP
SERVICE ITEM
1/2
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE IS 6" OFFSET OF OVERALL LENGTH AND
WIDTH OF GENERATOR. {1193.8 (47") WIDE X 2255.5 (88.8") LONG}. REFERENCE
INSTALLATION GUIDE SUPPLIED WITH THE UNIT FOR CONCRETE PAD GUIDELINES.
REFERENCE MANUFACTURER'S SPECIFICATIONS IF USING ENGINEERED, PREFABRICATED SLABS.
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR.
4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB-UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES.
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC
SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS.
10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE
AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED.
11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE,
VICE ACTION LATCH,
REMOVE FRONT PANEL TO ACCESS.
ONE PER DOOR,
759 [29.9]
ONE LIFT OFF
DOOR TYP.
DOOR PER SIDE
OF GENERATOR
B
REAR ENCLOSURE
COVER PANEL
SEE NOTE 4
RADIATOR/EXHAUST
DISCHARGE AIR
1171
[46.1]
OVERALL
HEIGHT
50 [2.0]
A
LEFT SIDE VIEW
CUSTOMER ACCESS
ASSEMBLY, CONTROL
PANEL ACCESS,
BATTERY CHARGER
LOCATED WITHIN
SEE NOTE 4
1857 [73.1]
1000 [39.4]
1950 [76.8]
OVERALL LENGTH
FUEL LINE CONNECTION
3/4" NPT FEMALE COUPLING
A
RIGHT SIDE VIEW
REAR VIEW
WEIGHT DATA
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
ENGINE/KW
ENCLOSURE
MATERIAL
WEIGHT
GENSET ONLY
KG [LBS]
2.4L 60KW
ST
582 [1283]
44 [98]
626 [1381]
2.4L 60KW
AL
558 [1230]
44 [98]
602 [1328]
WEIGHT
SHIPPING SKID
KG [LBS]
SHIPPING WEIGHT
KG [LBS]
TITLE
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
4
3
INSTALL CPL PROT G2.4L C2 60KW
DIMENSIONS: MM [INCH]
2
ISSUE DATE:
SIZE
B
SCALE
CAGE NO
DWG NO
N/A
0.050
WT-KG
0L2090
SEE ABOVE SHEET
1
REV
1 of 2
D
4
SH
3
2/2
REV
D
WINDCHILL VERSION
D.1
1
13.5 X 29.5
MOUNTING SLOTS
4X
*NOTE: STUB-UP AREA FOR HIGH AND LOW VOLTAGE
CONNECTIONS, CIRCUIT BREAKER, NEUTRAL AND
CUSTOMER CONNECTION OPENING.
HIGH AND LOW
VOLTAGE
STUB-UP AREA
B
B
787
[31.0]
162 [6.4]
*STUB-UP
AREA
9
[.4]
37
[1.5]
1708
[67.2]
233
[9.2]
51
[2.0]
162
[6.4]
*STUB-UP
AREA
TOP VIEW
REMOVABLE
STUB-UP COVER
850 [33.5]
116
[4.6]
50 [2.0]
TYP
1750 [68.9] TYP
MOUNTING SLOT CENTERS
25 [1.0]
TYP
1950 [76.8]
A
838 [33.0] TYP
MOUNTING SLOT CENTERS
888 [35.0]
LEFT SIDE VIEW
TITLE
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
DIMENSIONS: MM [INCH]
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
4
A
REAR VIEW
3
2
INSTALL CPL PROT G2.4L C2 60KW
ISSUE DATE:
SIZE
B
SCALE
CAGE NO
DWG NO
N/A
0.100
WT-KG
0L2090
SEE SHEET 1 SHEET
1
REV
2 of 2