- Industrial & lab equipment
- Electrical equipment & supplies
- Power generators
- Generac
- 55 kW QT05554ANNNA
- Manual
advertisement
▼
Scroll to page 2
of 103
Serial Number Industrial QT 5.4L 55kW Models STANDBY GENERATOR OWNER'S MANUAL A new standard of reliability This manual should remain with the unit. Cover047 Rev. 0 04/06 Part No. 0G1213 Standby Generator Sets Table of Contents INTRODUCTION .....................................................1-3 Read this Manual Thoroughly ...................................1-3 Operation and Maintenance ......................................1-3 How to Obtain Service ..............................................1-3 IDENTIFICATION RECORD .....................................2-1 Data Label ................................................................2-1 EQUIPMENT DESCRIPTION ...................................3-1 Equipment Description ................................................3-1 Engine Oil Recommendations ......................................3-1 Coolant Recommendations...........................................3-1 ENGINE PROTECTIVE DEVICES ............................4-1 Coolant Temperature Sensing ...................................4-1 Low Coolant Level.....................................................4-1 Oil Pressure Sensing .................................................4-1 Overcrank Shutdown ................................................4-1 Overspeed Shutdown ................................................4-1 RPM Sensor Loss Shutdown.....................................4-1 DC Fuse ....................................................................4-1 FUEL SYSTEMS .....................................................5-1 Fuel Requirements ....................................................5-1 Natural Gas Fuel System ..........................................5-1 Propane Vapor Withdrawal Fuel System....................5-1 LP Fuel System .........................................................5-1 SPECIFICATIONS ...................................................6-1 Generator .................................................................6-1 Engine.......................................................................6-1 Cooling System .........................................................6-1 Fuel System ..............................................................6-1 Electrical System ......................................................6-1 5.4L & 6.8L Ignition Description .................................6-3 Ignition Power-up Input (“56 Line Input”) .................6-3 Ignition Enable (“14 Line Input”) ..............................6-3 Ignition Shutdown on Loss of Crank or CAM Signals .........................................................6-3 Diagnostic Blink Patterns (Red LED Located on the Ignition Control Board ...................................6-3 GENERAL INFORMATION.......................................7-1 Generator AC Lead Connections ..................................7-1 Alternator Power Winding Connections ........................7-1 Four-lead, Single-phase Stator ..................................7-1 3-phase Alternators ("Y" Configuration) ....................7-1 3-phase Alternators ("Delta" Configuration) ..............7-2 INSTALLATION.......................................................8-1 Installation ...................................................................8-1 Preparation Before Start-up .........................................8-1 Transfer Switch ........................................................8-1 Fuel System ..............................................................8-1 Generator Set Lubrication ........................................8-1 Prior to Initial Start-up .............................................8-1 Engine Coolant .........................................................8-1 Belt Tension ..............................................................8-1 Electrical System ......................................................8-1 Initial Inspection for QT Genset Start-up .....................8-1 Start-up Checklist ........................................................8-2 Preparation for Start-up............................................8-2 Start-up Inspection ...................................................8-2 OPERATION ...........................................................9-1 Generator Control and Operation ................................9-1 Operating Unit with Manual Transfer Switch ...............9-1 Engine Start-up and Transfer ...................................9-1 Retransfer and Shutdown .........................................9-1 Operating Unit with Automatic Transfer Switch ...........9-1 MAINTENANCE.....................................................10-1 Maintenance Performed by Authorized Service Facilities .....................................................10-1 Every Three Months ...............................................10-1 Once Every Six Months ...........................................10-1 Once Annually.........................................................10-1 First 100 Operating Hours ......................................10-1 Every 500 Operating Hours ....................................10-1 Cooling System ..........................................................10-1 Checking Fluid Levels ................................................10-1 Check Engine Oil ....................................................10-1 Battery Fluid ...........................................................10-1 Engine Coolant .......................................................10-2 Maintenance Owner/Operator Can Perform ................10-2 Check Engine Oil Level ...........................................10-2 Check Battery .........................................................10-2 Exercise System ......................................................10-2 Inspect Cooling System ...........................................10-2 Check Engine Coolant Level....................................10-2 Perform Visual Inspection .......................................10-2 Inspect Exhaust System ..........................................10-2 Check Fan Belt........................................................10-2 Inspect Engine Governor ........................................10-2 Changing Engine Oil ...............................................10-2 Changing the Engine Air Cleaner ............................10-3 Spark Plugs ............................................................10-3 Coolant Change .......................................................10-3 Miscellaneous Maintenance ........................................10-3 Cleaning the Generator ...........................................10-3 Battery ....................................................................10-4 Battery Maintenance ...............................................10-4 Battery Replacement ...............................................10-4 SERVICE SCHEDULE ...........................................11-1 30 kW - 150 kW Standby Gas Engine Driven Generator Sets ............................................11-1 TROUBLESHOOTING ...........................................12-1 Troubleshooting Guide...............................................12-1 NOTES EXPLODED VIEWS & PARTS LISTS WIRING DIAGRAMS & SCHEMATICS WARRANTY Content010 Rev. 0 04/06 SECTION PAGE SAFETY RULES ................................................ 1-1 Stationary Emergency Generator Important Safety Instructions INTRODUCTION This symbol points out potential fire hazard. symbol points out potential electrical shock This hazard. Thank you for purchasing this model of the Stationary Emergency Generator set product line. Every effort was expended to make sure that the information and instructions in this manual were both accurate and current at the time the manual was written. However, the manufacturer reserves the right to change, alter or otherwise improve this product(s) at any time without prior notice. The operator is responsible for proper and safe use of the equipment. The manufacturer strongly recommends that the operator read this Owner's Manual and thoroughly understand all instructions before using this equipment. The manufacturer also strongly recommends instructing other users to properly start and operate the unit. This prepares them if they need to operate the equipment in an emergency. READ THIS MANUAL THOROUGHLY If any portion of this manual is not understood, contact the nearest Authorized Service Dealer for starting, operating and servicing procedures. OPERATION AND MAINTENANCE It is the operator's responsibility to perform all safety checks, to make sure that all maintenance for safe operation is performed promptly, and to have the equipment checked periodically by an Authorized Service Dealer. Normal maintenance service and replacement of parts are the responsibility of the owner/operator and, as such, are not considered defects in materials or workmanship within the terms of the warranty. Individual operating habits and usage contribute to the need for maintenance service. Throughout this publication, and on tags and decals affixed to the generator, DANGER, WARNING, CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular service or operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully. Their definitions are as follows: DANGER After this heading, read instructions that, if not strictly complied with, will result in serious personal injury, including death, or property damage. Proper maintenance and care of the generator ensure a minimum number of problems and keep operating expenses at a minimum. See an Authorized Service Dealer for service aids and accessories. Operating instructions presented in this manual assume that the generator electric system has been installed by an Authorized Service Dealer or other competent, qualified contractor. Installation of this equipment is not a “do-it-yourself” project. After this heading, read instructions that, if not strictly complied with, may result in personal injury or property damage. HOW TO OBTAIN SERVICE After this heading, read instructions that, if not strictly complied with, could result in damage to equipment and/or property. NOTE: When the generator requires servicing or repairs, simply contact an Authorized Service Dealer for assistance. Service technicians are factory-trained and are capable of handling all service needs. After this heading, read explanatory statements that require special emphasis. When contacting an Authorized Service Dealer or the factory about parts and service, always supply the complete model number of the unit as given on the front cover of this manual or on the DATA LABEL affixed to the unit. These safety warnings cannot eliminate the hazards that they indicate. Common sense and strict compliance with the special instructions while performing the service are essential to preventing accidents. Four commonly used safety symbols accompany the DANGER, WARNING and CAUTION blocks. The type of information each indicates is as follows: To locate the nearest AUTHORIZED SERVICE DEALER, please call this number: This symbol points out important safety information that, if not followed, could endanger personal safety and/or property of others. 1-800-333-1322 symbol points out potential explosion This hazard. or locate us on the web at: www.generac.com 1-1 Safety 001 Rev. B 10/08 AUTHORIZED SERVICE DEALER LOCATION Stationary Emergency Generator Important Safety Instructions SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted in potential hazard areas. Safety should be stressed to all operators, potential operators, and service and repair technicians for this equipment. WARNING: GENERAL HAZARDS • For safety reasons, the manufacturer recommends that this equipment be installed, serviced and repaired by an Authorized Service Dealer or other competent, qualified electrician or installation technician who is familiar with applicable codes, standards and regulations. The operator also must comply with all such codes, standards and regulations. • Installation, operation, servicing and repair of this (and related) equipment must always comply with applicable codes, standards, laws and regulations. Adhere strictly to local, state and national electrical and building codes. Comply with regulations the Occupational Safety and Health Administration (OSHA) has established. Also, ensure that the generator is installed, operated and serviced in accordance with the manufacturer’s instructions and recommendations. Following installation, do nothing that might render the unit unsafe or in noncompliance with the aforementioned codes, standards, laws and regulations. • The engine exhaust fumes contain carbon monoxide gas, which can be DEADLY. This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. For that reason, adequate ventilation must be provided. This should be considered prior to installing the generator. The unit should be positioned to direct exhaust gasses safely away from any building where people, animals, etc., will not be harmed. Any exhaust stacks that ship loose with the unit must be installed properly per the manufacturer's instruction, and in strict compliance with applicable codes and standards. • Keep hands, feet, clothing, etc., away from drive belts, fans, and other moving or hot parts. Never remove any drive belt or fan guard while the unit is operating. • Adequate, unobstructed flow of cooling and ventilating air is critical in any room or building housing the generator to prevent buildup of explosive gases and to ensure correct generator operation. Do not alter the installation or permit even partial blockage of ventilation provisions, as this can seriously affect safe operation of the generator. • Keep the area around the generator clean and uncluttered. Remove any materials that could become hazardous. • When working on this equipment, remain alert at all times. Never work on the equipment when physically or mentally fatigued. • Inspect the generator regularly, and promptly repair or replace all worn, damaged or defective parts using only factory-approved parts. The engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth defects or other reproductive harm. WARNING: This product contains or emits chemicals known to the state of California to cause cancer, birth defects or other reproductive harm. Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely, efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental rules or precautions. The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and on tags and decals affixed to the unit are, therefore, not all inclusive. If a procedure, work method or operating technique is used that the manufacturer does not specifically recommend, ensure that it is safe for others. Also make sure the procedure, work method or operating technique utilized does not render the generator unsafe. DANGER the safe design of this generator, Despite operating this equipment imprudently, neglecting its maintenance or being careless can cause possible injury or death. Permit only responsible and capable persons to install, operate or maintain this equipment. lethal voltages are generated by Potentially these machines. Ensure all steps are taken to render the machine safe before attempting to work on the generator. of the generator are rotating and/or hot Parts during operation. Exercise care near running generators. 1-2 Safety 001 Rev. B 10/08 Stationary Emergency Generator Important Safety Instructions • Before performing any maintenance on the generator, disconnect its battery cables to prevent accidental start-up. Disconnect the cable from the battery post indicated by a NEGATIVE, NEG or (–) first. Reconnect that cable last. • Never use the generator or any of its parts as a step. Stepping on the unit can stress and break parts, and may result in dangerous operating conditions from leaking exhaust gases, fuel leakage, oil leakage, etc. • Stationary Emergency Generators installed with an automatic transfer switch will crank and start automatically when normal (utility) source voltage is removed or is below an acceptable preset level. To prevent such automatic start-up and possible injury to personnel, disable the generator’s automatic start circuit (battery cables, etc.) before working on or around the unit. Then, place a “Do Not Operate” tag on the generator control panel and on the transfer switch. • In case of accident caused by electric shock, immediately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a nonconducting implement, such as a dry rope or board, to free the victim from the live conductor. If the victim is unconscious, apply first aid and get immediate medical help. • Never wear jewelry when working on this equipment. Jewelry can conduct electricity resulting in electric shock, or may get caught in moving components causing injury. ELECTRICAL HAZARDS • All Stationary Emergency Generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as well as the generator. Avoid contact with bare wires, terminals, connections, etc., on the generator as well as the transfer switch, if applicable. Ensure all appropriate covers, guards and barriers are in place before operating the generator. If work must be done around an operating unit, stand on an insulated, dry surface to reduce shock hazard. • Do not handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MAY RESULT. • If personnel must stand on metal or concrete while installing, operating, servicing, adjusting or repairing this equipment, place insulative mats over a dry wooden platform. Work on the equipment only while standing on such insulative mats. • The National Electrical Code (NEC) requires the frame and external electrically conductive parts of the generator to be connected to an approved earth ground. This grounding will help prevent dangerous electrical shock that might be caused by a ground fault condition in the generator or by static electricity. Never disconnect the ground wire. • Wire gauge sizes of electrical wiring, cables and cord sets must be adequate to handle the maximum electrical current (ampacity) to which they will be subjected. • Before installing or servicing this (and related) equipment, make sure that all power voltage supplies are positively turned off at their source. Failure to do so will result in hazardous and possibly fatal electrical shock. • Connecting this unit to an electrical system normally supplied by an electric utility shall be by means of a transfer switch so as to isolate the generator electric system from the electric utility distribution system when the generator is operating. Failure to isolate the two electric system power sources from each other by such means will result in damage to the generator and may also result in injury or death to utility power workers due to backfeed of electrical energy. FIRE HAZARDS • Keep a fire extinguisher near the generator at all times. Do NOT use any carbon tetra-chloride type extinguisher. Its fumes are toxic, and the liquid can deteriorate wiring insulation. Keep the extinguisher properly charged and be familiar with its use. If there are any questions pertaining to fire extinguishers, consult the local fire department. EXPLOSION HAZARDS • Properly ventilate any room or building housing the generator to prevent build-up of explosive gas. • Do not smoke around the generator. Wipe up any fuel or oil spills immediately. Ensure that no combustible materials are left in the generator compartment, or on or near the generator, as FIRE or EXPLOSION may result. Keep the area surrounding the generator clean and free from debris. • These generators may operate using one of several types of fuels. All fuel types are potentially FLAMMABLE and/or EXPLOSIVE and should be handled with care. Comply with all laws regulating the storage and handling of fuels. Inspect the unit’s fuel system frequently and correct any leaks immediately. Fuel supply lines must be properly installed, purged and leak tested according to applicable fuel-gas codes before placing this equipment into service. • Diesel fuels are highly FLAMMABLE. Gaseous fluids such as natural gas and liquid propane (LP) gas are extremely EXPLOSIVE. Natural gas is lighter than air, and LP gas is heavier than air; install leak detectors accordingly. Safety 001 Rev. B 10/08 1-3 Stationary Emergency Generator General Information IDENTIFICATION RECORD Identification Code DATA LABEL Use this code to obtain important information about the generator. For example, if the code is: Every generator set has a DATA LABEL that contains important information pertinent to the generator. The data label, which can be found attached to the generator’s lower connection box, lists the unit’s serial number and its rated voltage, amps, wattage capacity, phase, frequency, rpm, power factor, production date, etc. MADE IN USA RATED KVA RATED KW POWER FACTOR PHASE RATED AMPS RATED VOLTAGE HERTZ ALT RPM PRODUCTION DATE ENGINE RPM ALTERNATOR SUBTRANSIENT REACTANCE ALTERNATOR TRANSIENT REACTANCE CLASS ROTOR 0 5 4 A N S N A M — Designates generators capable of paralleling. NOTE: Only 100kW and 150kW, 6.8L units are currently available for this configuration. QT — Quiet Test Generator Series 100 — kw Rating 5.4 — Engine Size in Liters A — Voltage Code: A = 120/240, Single-phase; G = 120/208, Three-phase; K = 277/480, Three-phase; J = 120/240, Three-phase; L = 346/600, Three-phase N — Fuel: N = Natural Gas; V = Vapor Propane S — Enclosure Material: A = Aluminum; S = Steel (Corrosion Resistant Aluminum Enclosure Material, Steel is Standard) N — Emission Equipment: N = No Equipment; Y = Catalytic Converter and Air/Fuel Ratio Controller A — Industrial Dealer Product SERIAL MODEL 0 STATOR WINDING INSULATION AT 25°C AMBIENT GENERAC POWER SYSTEMS, INC. WAUKESHA, WI Voltage Codes NOTE: For actual information related to this particular model, please refer to the Manual Drawing Listing located at the end of this manual, or to the data label affixed to the unit. The identification code letter following the unit’s engine size is the generator’s “voltage code.” Groups and Assembly Numbers The manual drawing listing lists the groups and corresponding assembly numbers for each unit. The assembly numbers refer to exploded view drawing numbers that are applicable to the specific generator model. These drawings are located in the back half of this manual. Stationary Emergency Generator Model and Serial Number This number is the key to numerous engineering and manufacturing details pertaining to your unit. Always supply this number when requesting service, ordering parts or seeking information. 2-1 Identy001 Rev. D 10/08 GENERATOR SET DATA M Q T 1 Stationary Emergency Generator Equipment Description EQUIPMENT DESCRIPTION COOLANT RECOMMENDATIONS This equipment is a revolving field, alternating current Stationary Emergency Generator. It is powered by a gaseous fueled engine operating at 1800 rpm for 4-pole direct drive units, 3600 rpm for 2-pole direct drive units and 2300 - 3000 rpm for quiet drive gear units. See the Specifications section for exact numbers. The unit comes complete with a sound attenuated enclosure, internally mounted muffler, control console, mainline circuit breaker, battery charger, and protective alarms as explained in the following paragraph. Use a mixture of half low silicate ethylene glycol base anti-freeze and deionized water. Cooling system capacity is listed in the specifications. Use only deionized water and only low silicate anti-freeze. If desired, add a high quality rust inhibitor to the recommended coolant mixture. When adding coolant, always add the recommended 50-50 mixture. The Stationary Emergency Generator incorporates the following alternator features: mium hydroxide (“green slime”) forms and will cause overheating. Engines that have been operated with a chromate base rust inhibitor must be chemically cleaned before adding ethylene glycol base anti-freeze. Using any high silicate anti-freeze boosters or additives will also cause overheating. The manufacturer also recommends that any soluble oil inhibitor is NOT used for this equipment. not use any chromate base rust inhibitor Do with ethylene glycol base anti-freeze or chro- • Rotor and Stator insulation is Class H rated as defined by NEMA MG1-32.6, NEMA MG1-1.66. The generator is self ventilated and drip-proof constructed. • The voltage waveform deviation, total harmonic content of the AC waveform and telephone influence factor have been evaluated and are acceptable according to NEMA MG1-32. DANGER ENGINE OIL RECOMMENDATIONS not remove the radiator pressure cap while Do the engine is hot or serious burns from boiling The unit has been filled with 15W-40 engine oil at the factory. Use a high-quality detergent oil classified “For Service SJ or SH.” Detergent oils keep the engine cleaner and reduce carbon deposits. Use oil having the following SAE viscosity rating, based on the ambient temperature range anticipated before the next oil change: Temperature Above 80° F (27° C) 32° to 80° F (0° to 27° C) Below 32° F (0° C) liquid or steam could result. glycol base antifreeze is poisonous. Ethylene Do not use mouth to siphon coolant from the radiator, recovery bottle or any container. Wash hands thoroughly after handling. Never store used antifreeze in an open container because animals are attracted to the smell and taste of antifreeze even though it is poisonous to them. Oil Grade (Recommended) SAE 30W or 15W-40 SAE 20W-20 or 15W-40 See Note attempt to crank or start the engine before Any it has been properly serviced with the recommended oil may result in an engine failure. NOTE: For temperatures below 32° F, it is strongly recommended to use the optional Cold Weather Start Kit (part number listed in the Specification Section). The oil grade for temperatures below 32° F is 5W30 synthetic oil. Equip005 Rev. B 10/08 3-1 Stationary Emergency Generator Engine Protective Devices ENGINE PROTECTIVE DEVICES OIL PRESSURE SENSING The Stationary Emergency Generator may be required to operate for long periods of time without an operator on hand to monitor such engine conditions as coolant temperature, oil pressure or rpm. For that reason, the engine has several devices designed to protect it against potentially damaging conditions by automatically shutting down the unit when the oil pressure is too low, the coolant temperature is too high, the coolant level is too low, or the engine is running too fast. An analog Oil Pressure Sender (OPS) is used for monitoring the engine oil pressure. This sender allows the control panel to measure and display the Engine oil pressure. The OPS is a resistive device, whose resistance changes based on engine oil pressure. The resistance of the sender results in a voltage being developed across the sender. As the oil pressure increases, the resistance will decrease, causing the voltage to decrease. This changing voltage is converted to 420mA signal by a signal conditioner module. The corresponding 4-20mA signal is read by the control panel and displayed as the oil pressure. NOTE: Engine protective switches and sensors are mentioned here for the reader's convenience. Also refer to the applicable control panel manual for additional automatic engine shutdown information. The control panel will monitor and display oil pressure anytime the DC input to the control panel is present. COOLANT TEMPERATURE SENSING Should the oil pressure drop below the 8 psi range, the engine shutdown is initiated. The unit should not be restarted until oil is added. Turn the AUTO/OFF/ MANUAL switch to the OFF position, then back to AUTO to restart. An analog Water Temperature Sender (WTS) is located in the engine's cooling system. This sender is connected to the panel and allows the panel to monitor and display the temperature of the coolant system. The WTS is a resistive device whose resistance changes based on coolant temperature. The resistance of the sender results in a voltage being developed across the sender. As the Coolant temperature increases, the resistance will decrease, causing the voltage to decrease. This changing voltage is converted to 420mA signal by a signal conditioner module. The corresponding 4-20mA signal is read by the control panel and displayed as the coolant temperature. OVERCRANK SHUTDOWN When the control panel receives a start signal, it initiates the programmed starting sequence. The start sequence consists of the number of crank attempts, the length of each crank attempt, and the rest time between each crank attempt. If the engine has not started by the end of the final crank attempt, an Overcrank alarm is generated, the control panel will sound the alarm and display the message "Failed to start". The control panel will monitor and display the coolant temperature anytime the DC input to the control panel is present. OVERSPEED SHUTDOWN If the temperature exceeds approximately 140° C (284° F), the engine shutdown will be initiated. The generator will automatically restart and the display will reset once the temperature has returned to an operating level. A speed circuit controls engine cranking, start-up, operation and shutdown. Engine speed signals are delivered to the circuit board whenever the unit is running. Should the engine over speed above a safe, preset value, the circuit board initiates an automatic engine shutdown. Contact the nearest Authorized Dealer if this failure occurs. LOW COOLANT LEVEL A Low Coolant Level (LCL) sensor is placed in the generators coolant system. This sensor allows the panel to detect a Low Coolant Level condition. RPM SENSOR LOSS SHUTDOWN The LCL is a resistive device whose resistance changes rapidly based on the presence or absence of coolant. If the speed signal to the control panel is lost, engine shutdown will occur. The resistance of the LCL results in a voltage being developed across the LCL. This voltage changes as the resistance changes. This changing voltage is converted to 4-20mA signal by a signal conditioner module. The corresponding 4-20mA signal is read by the control panel and displayed as the low coolant level. DC FUSE This fuse is located inside of the control panel. It protects the panel wiring and components from damaging overload. Always remove this fuse before commencing work on the generator. The unit will not start or crank if the fuse is blown. Replace the fuse with one of the same size, type, and rating. (See the exploded views and parts lists at the end of this manual for replacement part number.) 4-1 EngProt002 Rev. C 10/08 If the level of the engine coolant drops below the level of the low coolant level sensor, the engine shutdown will be initiated. Stationary Emergency Generator Fuel Systems FUEL SYSTEM PROPANE VAPOR WITHDRAWAL FUEL SYSTEM This type of system utilizes the vapors formed above the liquid fuel in the supply tank. Approximately 10 to 20 percent of the tank capacity is needed for fuel expansion from the liquid to the vapor state. The vapor withdrawal system is generally best suited for smaller engines that require less fuel. The installer should be aware of the following: FUEL REQUIREMENTS The Stationary Emergency Generator may be equipped with one of the following fuel systems: • Natural gas fuel system • Propane vapor (PV) fuel system • Liquid propane (LP) fuel system • When ambient temperatures are low and engine fuel consumption is high, the vapor withdrawal system may not function efficiently. • Ambient temperatures around the supply tank must be high enough to sustain adequate vaporization, or the system will not deliver the needed fuel volume. • In addition to the cooling effects of ambient air, the vaporization process itself provides an additional cooling effect. The Manual Drawing Listing that is affixed to the unit includes the “Identification Code,” which may be used to identify the type of fuel system installed on the unit. Recommended fuels should have a Btu content of at least 1,000 Btu's per cubic foot for natural gas; or at least 2,520 Btu's per cubic foot for LP gas. Ask the fuel supplier for the Btu content of the fuel. LP LIQUID FUEL SYSTEM Required fuel pressure for natural gas is 5 inches to 14 inches water column (0.18 to 0.5 psi); and for liquid propane, 5 inches to 14 inches of water column (0.18 to 0.5 psi). LP is supplied as a liquid in pressure tanks. It is usually made up of propane, butane, or a mixture of the two gases. Propane tends to vaporize readily even at temperatures as low as -20° F (-29° C). However, butane reverts to its liquid state when temperatures drop below 32° F (0° C). NOTE: Any piping used to connect the generator to the fuel supply should be of adequate size to ensure the fuel pressure NEVER drops below five inches water column for natural gas or 5 inches water column for propane vapor for all load ranges. The fuel supply piping shall be sized according to the installation manual using the fuel consumption requirements identified in the Specifications section of the Owner's Manual. LP in a liquid withdrawal system must be converted to its gaseous state before it is introduced into the engine carburetor. A vaporizerconverter is generally used to accomplish this. In such a converter, heated engine coolant is ported through the converter to provide the necessary heat for conversion of the fuel from a liquid to a gaseous state. NOTE: It is the responsibility of the installer to make sure that only the correct recommended fuel is supplied to the generator fuel system. Thereafter, the owner/operator must make certain that only the proper fuel is supplied. NATURAL GAS FUEL SYSTEM Natural gas is supplied in its vapor state. In most cases, the gas distribution company provides piping from the main gas distribution line to the standby generator site. The following information applies to natural gas fuel systems. • Gas pressure in a building is usually regulated by national, state and local codes. • To reduce gas pressure to a safe level before the gas enters a building, a primary regulator is needed. The natural gas supplier may or may not supply such a regulator. • It is the responsibility of the gas supplier to make sure sufficient gas pressure is available to operate the primary regulator. • Gas pressure at the inlet to the fuel shutoff solenoid should not exceed approximately 14 inches water column (0.5 psi). FuelSys001 Rev. C 05/09 5-1 Stationary Emergency Generator Specifications SPECIFICATIONS Engine Lubrication System Type of Oil Pump ...................................................................... Gear Oil Filter .............................................................Full Flow, Cartridge Crankcase Oil Capacity ....................................................5 U.S. qts. STATIONARY EMERGENCY GENERATOR Type ............................................................................. Synchronous Rotor Insulation ......................Class F or Class H (see Data Label) Stator Insulation .................................................................. Class H Total Harmonic Distortion ......................................................< 3.5% Telephone Interference Factor (TIF) ..........................................< 50 Alternator Output Leads 1-phase ........................................... 4-wire Alternator Output Leads 3-phase ........................................... 6-wire Bearings .........................................................................Sealed Ball Coupling .......................................................................Flexible Disc Load Capacity (Standby Rating) ............................................55kW* * NOTE: Generator rating and perfomance in accordance with ISO8528-5, BS5514, SAE J1349, COOLING SYSTEM Type .......................................................................................Closed Water Pump.................................................................... Belt Driven Fan Speed ................................................................................ 2090 Fan Diameter .....................................................................22 inches Fan Mode ..............................................................................Pusher Air Flow (inlet air including alternator and combustion air) .......................................................... 4350 ft3/min. Coolant Capacity ........................................................ (4.0 U.S. gal.) Heat Rejection to Coolant ..........................................210,000 Btu/h Maximum Operating Air Temp. on Radiator ..............60° C (150° F) Maximum Ambient Temperature................................50° C (140° F) ISO3046 and DIN 6271 Standards. KW rating is based on LPG fuel and may derate with natural gas. Excitation System ............................................................. Brushless Generator Output Voltage/kW - 60 Hz kW Amp CB Size 120/240V, 1-phase, 1.0 pf 55 229 250 120/208V, 3-phase, 0.8 pf 55 191 225 120/240V, 3-phase, 0.8 pf 55 165 200 277/480V, 3-phase, 0.8 pf 55 83 100 Generator Locked Rotor KVA Available @ Voltage Dip of 35% Single-phase .................................................................... 115 KVA 480V, 3-phase .................................................................. 146 KVA 208V, 3-phase .................................................................. 110 KVA 240V, 3-phase .................................................................. 110 KVA FUEL SYSTEM Type of Fuel ........................................Natural Gas, Propane Vapor* Carburetor ...................................................................... Down Draft Secondary Fuel Regulator .................................................Standard Fuel Shut-off Solenoid ........................................................Standard Operating Fuel Pressure ...................... 5 in. - 14 in. Water Column Fuel Consumption - ft3/hr (Natural Gas/LPV) Exercise 25% 50% 75% 100% Cycle Load Load Load Load 95/38 204/82 392/157 547/220 756/302 ENGINE Make ................................................................................... Generac Model ...................................................................................... V-type Cylinders and Arrangement............................................................ 8 Displacement ....................................................................... 5.4 Liter Bore ...................................................................................... 3.55 in. Stroke ................................................................................... 4.17 in. Compression Ratio ..................................................................9-to-1 Air Intake System ...............................................Naturally Aspirated Valve Seats....................................................................... Hardened Lifter Type .......................................................................... Hydraulic * Engine is not field convertible between natural gas and propane. Jet size and ignition timing are factory set for the specific fuel. ELECTRICAL SYSTEM Battery Charge Alternator ............................................12V, 30 Amp Static Battery Charger ..................................................12V, 10 Amp Recommended Battery................................................ 24F 525CCA System Voltage .....................................................................12 Volts Voltage Regulator Type ................................................................................. Full Digital Sensing................................................................................ 3-phase Regulation .............................................................................± 1/4% Features ...........................................Built into H-100 Control Panel, V/F Adjustable, Adjustable Voltage and Gain Engine Parameters Rated Synchronous RPM ..............................................60 Hz, 1800 HP at rated kW ..................................................................60 Hz, 88 Exhaust System Exhaust Flow at Rated Output 60 Hz.................................. 414 cfm Exhaust Temperature at Rated Output .................................. 800° F Power Adjustment for Ambient Conditions Temperature Deration 3% for every 10° C above °C ..................................................... 25 1.65% for every 10° above °F .................................................... 77 Altitude Deration 1% for every 100 m above m ................................................... 183 3% for every 1000 ft. above ft. ................................................. 600 Combustion Air Requirements (Natural Gas) Flow at rated power, 60 Hz ................................................. 163 cfm Governor Type .................................................................................. Electronic Frequency Regulation ...................................................Isochronous Steady State Regulation.......................................................± 1/4 % Controller .............................................. H-panel GenSpec023 Rev. A 10/08 6-1 Stationary Emergency Generator Specifications Figure 1 — Interconnections H-100 CONTROL PANEL Utility In Transfer Switch NEUTRAL Gen RS485 + RS485 - TO ALTERNATOR NEUTRAL ALTERNATOR CONNECTION BOX RS485 + RS485 Grd. Remote Start Remote Start CIRCUIT BREAKER GROUND 2 WIRE SHIELDED CABLE W/GROUND TO TRANSFER SW GROUND AT ALTERNATOR CONNECTION BOX ONLY FRAME RAIL STUB-UP AREA See Install Dwg for Dimensions Ground Level Concrete Slab Figure 2 — AC Outlets for Block Heater and Battery Charger (to be wired by installer) 6-2 2 WIRE SHIELDED CABLE W/GROUND TO ALTERNATOR CONNECTION BOX Sig B4 Xfer Sig B4 Xfer Load Out TO ALTERNATOR CONNECTION BOX GenSpec023 Rev. A 10/08 Stationary Emergency Generator Specifications 5.4L & 6.8L IGNITION DESCRIPTION NOTE: This single-fire Ignition is intended to operate with a 10-cylinder, 6.8L engine and an 8-cylinder, 5.4L engine. The ignition cover does not need to be removed to see the LED. The 6.8L engine uses a 40-1 crank sensor, a magpickup CAM sensor and individual coil-on-plug coils for each spark-plug. IGNITION SHUTDOWN ON LOSS OF CRANK OR CAM SIGNALS The ignition will stop firing the coils immediately following the loss of the crank signal. The ignition will stop firing the coils after approx. 3 seconds following the loss of the cam signal. The 5.4L engine uses a 36-1 crank sensor, a magpick-up CAM sensor and individual coil-on-plug coils for each spark-plug. With a single-fire ignition, each high-voltage coil output is connected to one spark plug resulting in that spark plug being fired only during the compression cycle. DIAGNOSTIC BLINK PATTERNS (RED LED LOCATED ON THE IGNITION CONTROL BOARD) Engine Timing versus Engine Speed for the 6.8L engine is: During normal ignition operation the RED LED flashes at a 0.5 sec ON and a 0.5 sec OFF rate. This is considered one (1) blink. RPM NG/LP Engine Timing (BTDC) 1800 rpm 22 degrees 3600 rpm 24 degrees Engine Timing versus Engine Speed for the 5.4L engine is: RPM 1800 rpm 3600 rpm LED Fault Code with Priority as shown: 1. No Crank Signal: LED blinks 2 times, is OFF for 3.0 seconds and then repeats 2. No CAM Signal: LED blinks 3 times, is OFF for 3.0 seconds and then repeats Only one fault is displayed at a time. If multiple faults exist then the highest priority fault must be resolved prior to a lower priority fault being displayed. In the event that an ignition fault has occurred the ignition will wait 60 seconds before powering down. NG/LP Engine Timing (BTDC) 26 degrees 26 degrees IGNITION POWER-UP INPUT ("56 LINE INPUT") When battery voltage is applied to this input the ignition will power-up. For the ignition to power itself down, battery voltage must be removed from this input. NOTE: The ignition cover does not need to be removed to see the LED. IGNITION ENABLE ("14 LINE INPUT") This input must be connected to the +12V battery for the ignition to turn-on the coils. If this input is connected to battery ground the ignition will stop firing the coils and will power down within approximately 2 seconds. In the event that an ignition fault has occurred, however, the ignition will wait 60 seconds before powering down. This allows time to view the diagnostic LED located on the ignition board. GenSpec023 Rev. A 10/08 6-3 Stationary Emergency Generator General Information GENERATOR AC LEAD CONNECTIONS 3-PHASE ALTERNATORS ("Y" CONFIGURATION) See “Voltage Codes”. This Stationary Emergency Generator may be rated at any one of five voltages, either single-phase or three-phase. The electrical wires in the unit’s AC connection (lower) panel should be installed according to the number of leads and the voltage/phase required for the application. If there are any questions regarding lead connection, refer to the wiring diagrams at the back of this manual. The Stationary Emergency Generator is designed to supply 3-phase electrical loads. Electric power is produced in the alternator power windings. These windings were connected at the factory to the main circuit breaker with a “Y” configuration as shown in Figures 7.2, 7.3, and 7.4. The rated voltage between circuit breaker terminals E1-E2, E1-E3 and E2-E3 is either 480V or 208V depending on the model. Voltage codes apply to the type of stator assembly installed on a particular generator. The rated voltage between each circuit breaker terminal and the neutral point 00 is either 277V or 120V depending on the model. ALTERNATOR POWER WINDING CONNECTIONS Figure 7.2 — Stator Power Winding Connections - 3-phase, 120/208V (12 Lead) FOUR-LEAD, SINGLE-PHASE STATOR Four-lead generators are built to supply electrical loads with voltage code "A" (240V, 1-phase, 60Hz). Electrical power is produced in the stator power windings. These windings were connected at the factory to the main circuit breaker as shown in Figure 7.1. E1 The rated voltage between each circuit breaker terminal is 240V. The rated voltage between each circuit breaker terminal and the neutral point 00 is 120V. S7 S1 S10 S12 S4 S5 L-L Figure 7.1 — Four-lead, Single-phase Stator S9 S2 S6 S11 E3 E2 S3 S8 L-N Figure 7.3 — Stator Power Winding Connections - 3-phase, 277/480V (12 Lead) E1 S1 S4 S7 L-L S6 S3 E3 7-1 S9 S10 S11 S8 S5 L-N S2 E2 ACConn005 Rev. A 09/08 S12 Stationary Emergency Generator General Information 3-PHASE ALTERNATORS ("DELTA" CONFIGURATION) Figure 7.1 — Stator Power Winding Connections - 3-phase, 346/600V (6 Lead) The Stationary Emergency Generator is designed to supply 3-phase electrical loads. Electric power is produced in the alternator power windings. These windings were connected at the factory to the main circuit breaker with a “Delta” configuration as shown in Figures 7.5. S1 E1 INTERNAL CONNECTIONS The rated voltage between circuit breaker terminals E1-E2, E1-E3 and E2-E3 is 208V. The rated voltage between E1 or E3 and the neutral point 00 is 120V. L-L S6 S4 NEUTRAL Figure 7.5 — Stator Power Winding Connections - 3-phase, 120/240V (12 Lead) S5 E3 S3 S2 E2 E2 L-N E1 7-2 E ACConn005 Rev. A 09/08 Stationary Emergency Generator Installation INSTALLATION Also, if the engine is equipped with a mechanical governor, make sure the governor is properly lubricated with clean engine oil. Refer to the separate “Installation Guide QT Product Line” supplied with the unit. PRIOR TO INITIAL START-UP PREPARATION BEFORE START-UP The instructions in this section assume that the standby generator has been properly installed, serviced, tested, adjusted and otherwise prepared for use by a competent, qualified installation contractor. Be sure to read the “Safety Rules”, as well as all other safety information in this manual, before attempting to operate this (and related) equipment. to initially starting the generator, it must Prior be properly prepared for use. Any attempt to crank or start the engine before it has been properly serviced with the recommended types and quantities of engine fluids (oil, coolant, fuel, etc.) may result in an engine failure. Before starting the generator for the first time, the installer must complete the following procedures. For follow-up maintenance information and/or service intervals, please refer to the “Maintenance” section and the “Service Schedule”. ENGINE COOLANT Have the engine cooling system properly filled with the recommended coolant mixture. Check the system for leaks and other problems. See “Specifications” and “Coolant” sections. TRANSFER SWITCH BELT TENSION If this generator is used to supply power to any electrical system normally powered by an electric utility, the National Electrical Code requires that a transfer switch be installed. The transfer switch prevents electrical backfeed between two different electrical systems. (For additional information, see the applicable transfer switch manual for this unit.) The transfer switch, as well as the generator and other electrical components, must be properly located and mounted in strict compliance with applicable codes, standards and regulations. Check-the engine-fan belt tension and condition prior to placing the unit into service and at recommended intervals. Belt tension is correct when a force of approximately 22 pounds (10 kg), applied midway between pulleys, deflects the belt about 3/8- to 5/8inch (10 to 16 mm). ELECTRICAL SYSTEM Make sure the generator is properly connected to an approved earth ground. Make sure the generator battery is fully charged, properly installed and interconnected, and ready for use. FUEL SYSTEM Make sure the fuel supply system to the generator (a) delivers the correct fuel at the correct pressure and (b) is properly purged and leak tested according to code. No fuel leakage is permitted. See “Specifications” for more information. NOTE: Battery charger must be connected to 120 VAC, 15 amp circuit to operate. Check to ensure that there are no loose electrical connections. Restrain any loose wires to keep them clear of any moving generator set components. GENERATOR SET LUBRICATION Check the engine crankcase oil level before operating and add oil to the proper level – the dipstick “FULL” mark. Never operate the engine with the oil level below the dipstick “ADD” mark. See “Specifications” and “Engine Oil Recommendations”. INITIAL INSPECTION FOR QT GENSET STARTUP Inspect for the following. NOTE: • • • • • Freight Damage. Manuals present. Fluid Levels (Oil, coolant, battery, Gear Drive). Correct fuel piping. Correct muffler installation for QT45, QT55, QT80, QT100 - QT150. • Adequate air flow, clearances and ventilation per installation drawings and applicable codes. Check the oil level in the generator gearbox (if so equipped) prior to initial use and at the intervals indicated by the “Service Schedule.” The recommended oil is SAE 90 gear lubricant. 8-1 Install006 Rev. B 10/08 This engine is shipped from the manufacturer with “break-in” oil. This oil should be changed after 30 hours of operation. Stationary Emergency Generator Installation • Correct AC and DC wire size, connections and grounding. Control and communication wiring to/ from the transfer switch must be run in a separate conduit from the AC power leads. • AC outlet connection. • Communication wires connected between transfer switch and generator (HTS only). • Unit secured to pad. • Insert the fuse into the control panel. • Move the AUTO/OFF/MANUAL switch to the MANUAL position. The engine should now crank and start. • Check voltage at the generator terminals. • For 3-phase units, check phase rotation at the transfer switch terminals. The generator phase rotation must match the utility phase rotation. • Check for coolant, fuel, oil, and exhaust leaks. • Close the generators main line circuit breaker. • Turn the generator set off. • Connect the UTILITY supply to the transfer switch. • Set the AUTO/OFF/MANUAL switch to AUTO. • Disconnect utility power before the transfer switch. Engine should start, transfer to load. Run at least 15 minutes on generator power. Make certain all 3-phase loads are functioning correctly (correct phase rotation). • Reconnect Utility power Transfer switch will transfer back to Utility and engine will shut down within the given time parameters set up for the specific transfer switch and controller. • Install all covers, access plates and door panels. • Put the Owners Manual in a safe and accessible place. • Make certain the AUTO/OFF/MANUAL switch is in the AUTO position. START-UP CHECKLIST working on the Stationary Emergency Before Generator, ensure the following: • The AUTO/OFF/MANUAL switch is in the OFF position. • The power to the block heater and to the battery charger is switched OFF. PREPARATION FOR START-UP • Remove the fuse from the the control panel. For the H-100 and R-series: Open the front door of the control box and remove the 15 Amp ATO fuse in the lower left-hand corner of the control box. • Connect the battery cables to the battery. Attach negative battery cable last. • Restore power to the GFCI outlet that provides power to the battery charger. • Measure the voltage at the battery before and after the charger is turned on. • Verify all AC electrical connections are tight at the circuit breaker and transfer switch. • Visually inspect entire area looking for loose paper, plastic wrappings, leaves, etc. • Check all hoses clamps fittings for leaks or damage. • Check all electrical plugs throughout the generator. Ensure each plug is seated correctly and fully inserted into its receptacle. • Verify the AUTO/OFF/MANUAL switch is in OFF position. • Open the valve to the engine fuel line. • Bleed the fuel system of air. (necessary for long fuel lines). • Open the generator main line circuit breaker. • Connect a manometer to the gas line and record the static pressure. It must be as listed in the Specifications. START-UP INSPECTION When a start-up is performed by an Authorized Service Dealer, a standard three-part form titled “Start-up Inspection for Standby Power Systems” (part no. 067377), should be completed by the installation technician or engineer. See page 1-3 for information on locating the nearest Authorized Service Dealer. The installer should complete the form and disseminate copies as follows: • White copy: Mail to Generac Warranty Department, P.O. Box 340, 211 Murphy Dr., Eagle, WI 531192062. • Pink Copy: For service file of installing dealer. • Yellow Copy: For the customer’s records. 8-2 Install006 Rev. B 10/08 Stationary Emergency Generator Operation STATIONARY EMERGENCY GENERATOR CONTROL AND OPERATION not crank the engine continuously for longer Do than 30 seconds, or the heat may Refer to the appropriate control panel operator’s manual for this unit. • • OPERATING UNIT WITH MANUAL TRANSFER SWITCH If the Stationary Emergency Generator was installed in conjunction with a transfer switch capable of manual operation only, the following procedure applies. A manually operated transfer switch is one that will not provide automatic start-up and does not include an intelligence circuit. • • damage the starter motor. Let engine stabilize and warm up. Check all applicable instrument and gauge readings. When certain that all readings are correct, move the transfer switch manual handle to the STANDBY position, i.e., load circuits supplied by the generator. Set the generator’s main line circuit breaker to its ON (or CLOSED) position. Load circuits are now powered by the generator. RETRANSFER AND SHUTDOWN For additional information, refer to the applicable control panel manual for this unit, as well as any literature pertaining to the specific transfer switch. ENGINE START-UP AND TRANSFER For additional information, refer to the applicable control panel manual for this unit, as well as any literature pertaining to the specific transfer switch. To transfer the load back to the utility power source and shut down the generator, follow these directions: • Set the generator’s main line circuit breaker to its OFF (or OPEN) position. • Manually move the transfer switch handle to its UTILITY (NORMAL) position, i.e., load circuits connected to the utility. • Turn ON the utility power supply to the transfer switch, using the means provided (such as the utility power source main line circuit breaker). • Let the generator run at no-load for a few minutes to stabilize internal temperatures. • Shut down the generator. DANGER Maintenance Disconnect Switch and the The AUTO/OFF/MANUAL switches (if so equipped) must be set properly, or the generator will crank and start as soon as the utility power to the transfer switch is turned off. Refer to applicable control panel and transfer switch manuals for more information. not proceed until certain that utility source Do voltage is available to the transfer switch and the transfer switch main contacts are set to UTILITY. OPERATING UNIT WITH AUTOMATIC TRANSFER SWITCH not attempt manual operation until all power Do supplies to the transfer switch have been posi- If the Stationary Emergency Generator has been installed with an automatic transfer switch, the engine may be started and stopped automatically or manually. tively turned off, or extremely dangerous - possibly lethal - electrical shock will result. NOTE: switch enclosure doors should be kept Transfer closed and locked. Only authorized personnel Refer to the applicable manual for your transfer switch and to “Transfer Switch Start Signal Connections”. In addition, please note the dangers under “Engine Start-up and Transfer.” should be allowed access to the transfer switch interior. Extremely high and dangerous voltages are present in the transfer switch. In order to transfer load from the utility source to the generator, follow these directions: • Turn OFF or disconnect the utility power circuit to the transfer switch, using the means provided (such as the utility source main line circuit breaker). • Set the transfer handle to its UTILITY (NORMAL) position with load circuits connected to the utility power supply. • Set the generator’s main line circuit breaker to its OFF (or OPEN) position. • Start the generator. Oper001 Rev. B 06/09 9-1 Stationary Emergency Generator Maintenance MAINTENANCE PERFORMED BY AUTHORIZED SERVICE DEALERS exhaust system parts from this product get The extremely hot and remain hot after shutdown. High grass, weeds, brush, leaves, etc. must remain clear of the exhaust. Such materials may ignite and burn from the heat of the exhaust system. working on the Stationary Emergency Before Generator, ensure the following: • • • • The AUTO/OFF/MANUAL switch is in the OFF position. The 15A fuse has been removed from the control box. The 120VAC supply to the battery charger is switched OFF. The negative battery cable has been removed. CHECKING FLUID LEVELS CHECK ENGINE OIL Check engine crankcase oil level (Figure 10.1) at least every 20 hours of operation, or prior to use. EVERY THREE MONTHS 1. 2. 3. 4. 5. 6. Check battery state of charge and condition. Inspect and test fuel system. Check transfer switch. Inspect exhaust system. Check engine ignition system. Check fan belts. • • • • ONCE EVERY SIX MONTHS 1. Figure 10.1 - Oil Dipstick and Oil Fill Cap Test Engine Safety Devices (low oil pressure, low coolant level, high coolant temperature). Oil Fill ONCE ANNUALLY 1. 2. 3. 4. Remove oil dipstick and wipe dry with a clean, lint-free cloth. Install oil dipstick, then remove again. Oil should be between FULL and ADD marks. If oil level is below the dipstick ADD mark, remove oil fill cap. Add the recommended oil to bring oil level up to the FULL mark. DO NOT FILL ABOVE THE “FULL” MARK. See “Engine Oil Recommendations” for recommended oils. Test engine governor. Adjust or repair, if needed. Clean, inspect generator. Flush cooling system. Clean/re-gap spark plugs or replace as necessary. FIRST 30 OPERATING HOURS 1. Change engine "break-in" oil and oil filter. FIRST 100 OPERATING HOURS 1. Oil Dipstick Change engine oil and oil filter. (After initial change, service engine oil and filter at 150 operating hours or 6 months, whichever comes first.) EVERY 500 OPERATING HOURS 1. 2. 3. Oil Filter Service air cleaner. Check starter. Check engine DC alternator. BATTERY FLUID Check battery electrolyte fluid at least once weekly. Fluid should cover separators in all battery cells. If fluid level is low, add distilled water to cover tops of separators. DO NOT USE TAP WATER IN BATTERY. COOLING SYSTEM Air intake and outlet openings in the generator compartment must be open and unobstructed for continued proper operation. This includes such obstructions as high grass, weeds, brush, leaves and snow. Without sufficient cooling and ventilating air flow, the engine/generator quickly overheats, which causes it to shut down. Maint013 Rev. E 06/09 10-1 Stationary Emergency Generator Maintenance ENGINE COOLANT INSPECT EXHAUST SYSTEM Check coolant level in coolant recovery bottle. See the “Specifications” section. Inspect the exhaust system at least once every three months. Check all exhaust system pipes, mufflers, clamps, etc. for condition, tightness, leaks, security, damage. • Add recommended coolant mixture as necessary. • Periodically remove radiator pressure cap to make sure the coolant recovery system is functioning properly. Coolant should be at bottom of radiator filler neck. If coolant level is low, inspect gasket in radiator pressure cap. Replace cap, if necessary. To have pressure cap tested, contact an Authorized Service Dealer. Inspect cooling system and coolant recovery system for leaks. CHECK FAN BELT • Inspect fan belts every three months. Replace any damaged, deteriorated, worn or otherwise defective belt. • Check fan belt tension. Thumb pressure, exerted midway between pulleys, should deflect about 3/8 to 5/8 inch. Adjust belt tension as required. • Check fan belt alignment. MAINTENANCE OWNER/ OPERATOR CAN PERFORM INSPECT ENGINE GOVERNOR Visually inspect electronic governor. DANGER working on the generator, ensure the fol Before lowing: • • • • not attempt to adjust the governor. Only Do qualified service facilities should adjust the The AUTO/OFF/MANUAL switch is in the OFF position. The 15A fuse has been removed from the control box. The 120VAC supply to the battery charger is switched OFF. The negative battery cable has been removed. governor. Excessively high operating speeds are dangerous and increase the risk of personal injury. Low speeds impose a heavy load on the engine when adequate engine power is not available and may shorten engine life. Correct rated frequency and voltage are supplied only at the proper governed speed. Some connected electrical load devices may be damaged by incorrect frequency and/or voltage. Only qualified service technicians should adjust the governed speed. CHECK ENGINE OIL LEVEL Refer to the “Checking Fluid Levels” section. CHECK BATTERY • Check battery fluid level each week as outlined under “Check Fluid Levels”. • Check battery cables for condition, tightness, corrosion or damage. Clean, tighten or replace as necessary. CHANGING ENGINE OIL EXERCISE SYSTEM oil may cause burns. Allow engine to cool Hot before draining oil. Avoid prolonged or repeated Start the Stationary Emergency Generator engine at least once every seven days and let it run at least 20 minutes. For more detailed exercise information, see the respective sections in the Control Panel Technical Manual that is supplied with the unit. skin exposure with used oil. Thoroughly wash exposed areas with soap. Refer to maintenance performed by authorized service facilities for engine oil and filter change frequencies. INSPECT COOLING SYSTEM Drain the oil while the engine is still warm from running. This means warm up the engine, shut it down and drain immediately as follows: • Inspect engine cooling system at least once each month. • Check hoses for damage, deterioration, leaks, etc. Correct any discrepancies found. • Check hose clamps for tightness. 1. 2. CHECK ENGINE COOLANT LEVEL 3. See the “Checking Fluid Levels” section. 4. PERFORM VISUAL INSPECTION 5. Complete a thorough visual inspection of the entire engine-generator monthly. Look for obvious damage, loose, missing or corroded nuts, bolts and other fasteners. Look for fuel, oil or coolant leaks. 10-2 Remove OIL DRAIN HOSE from its retaining clip. Loosen and remove OIL DRAIN HOSE CAP. Drain oil completely into suitable container. When all oil has drained, install and tighten OIL DRAIN HOSE CAP, and re-install into its retaining clip. Turn OIL FILTER (Figure 10.2) counterclockwise and remove. Dispose of old filter. Apply light coating of new engine oil to seal of new oil filter.-Install FILTER and tighten by hand only. DO NOT OVERTIGHTEN. Maint013 Rev. E 06/09 Stationary Emergency Generator Maintenance 6. SPARK PLUGS Remove OIL FILL CAP. Add recommended oil (see SPECIFICATIONS). DO NOT FILL ABOVE THE DIPSTICK “FULL” MARK. Crankcase oil capacity is listed in the “Specifications”. Reset the spark plug gap or replace the spark plugs as necessary. 1. refilling the crankcase with oil, always After check oil level on dipstick. NEVER OPERATE 7. 8. 9. 2. ENGINE WITH OIL BELOW THE DIPSTICK “ADD” MARK. Start engine and check for oil leaks. Shut OFF engine and wait 10 minutes for the oil to settle down into the oil pan. Recheck oil level on dipstick. DO NOT fill above the dipstick "FULL" mark. Dispose of used oil at a proper collection center. 3. Clean the area around the base of the spark plugs to keep dirt and debris out of the engine. Clean by scraping or washing using a wire brush and commercial solvent. Do not blast the spark plugs to clean. Remove the spark plugs and check the condition. Replace the spark plugs if worn or if reuse is questionable. See the “Service Schedule” section for recommended inspection. Check the spark plug gap using a wire feeler gauge. Adjust the gap to 0.94 - 1.07 mm (0.037 - 0.042 inch) by carefully bending the ground electrode (Figure 10.4). Figure 10.4 – Setting the Spark Plug Gap Figure 10.2 - Oil Filter Oil Dipstick COOLANT CHANGE Every year, have an Authorized Service Facility drain, flush and refill the cooling system. See the “Specifications” section for cooling system recommendations. Oil Filter CHANGING THE ENGINE AIR CLEANER MISCELLANEOUS MAINTENANCE To replace the engine air cleaner, (part number 0A4637), remove the air cleaner cover and replace the air filter making sure it is positioned properly before reattaching the cover. CLEANING THE STATIONARY EMERGENCY GENERATOR Keep the generator as clean and as dry as possible. Dirt and moisture that accumulates on internal generator windings have an adverse effect on insulation resistance. Figure 10.3 — Engine Air Filter Periodically clean generator exterior surfaces. A soft brush may be used to loosen caked on dirt. Use a vacuum system or dry, low pressure air to remove any accumulations of dirt. The generator is housed inside an all-weather enclosure, clean the enclosure with a soft, damp cloth or sponge and water. Air Filter Once each year, have the generator cleaned and inspected by an Authorized Service Dealer. That dealer will use dry, low pressure air to clean internal windings. Parts inside the control console should be cleaned and inspected at this time as well. Finally, have the insulation resistance of stator and rotor windings checked. If insulation resistances are excessively low, the generator may require drying. See the “Service Schedule” section for air cleaner maintenance. Maint013 Rev. E 06/09 10-3 Stationary Emergency Generator Maintenance BATTERY electrolyte fluid is an extremely caus Battery tic sulfuric acid solution that can cause severe All lead-acid storage batteries discharge when not in use. Refer to specific instructions and warnings that accompany the battery. If such information is not available, observe the following precautions when handling a battery: burns. Do not permit fluid to contact eyes, skin, clothing, painted surfaces, etc. Wear protective goggles, protective clothing and gloves when handling a battery. If the fluid is spilled, flush the affected area immediately with clear water. • DO NOT use jumper cables and a booster battery to crank or start the generator engine. • DO NOT recharge a weak battery while it is installed in the generator. Remove battery from generator and recharge in a wellventilated area, away from fuel vapors, sparks, heat or flames. • Battery electrolyte fluid is an extremely caustic sulfuric solution that can cause severe burns. DO NOT permit fluid to contact eyes, skin, clothing, painted surfaces, wiring insulation, etc. If any battery fluid is spilled, flush the affected area with clear water immediately. • Always wear safety glasses, rubber apron and gloves when handling a battery. • Batteries give off explosive hydrogen gas while charging. The gas can form an explosive mixture around the battery for several hours after charging. Any spark, heat or flames can ignite the gas and cause an explosion which can shatter the battery, causing blindness or other serious injury. not use any jumper cables or booster battery Do to crank and start the generator engine. If the battery has completely discharged, remove it from the generator for recharging. sure the AUTO/OFF/MANUAL switch is set to Be the OFF position before connecting the battery cables. If the switch is set to AUTO or MANUAL, the generator can crank and start as soon as the battery cables are connected. sure the 120VAC power supply to the battery Be is turned OFF, or sparking may occur at the battery posts as the cables are attached and cause an explosion. BATTERY MAINTENANCE BATTERY REPLACEMENT The battery should be inspected per the “Service Schedule” section. The following procedure should be followed for inspection: 1. 2. 3. When replacing batteries, use the same number and type of battery that was supplied with the unit, and is listed in the parts list in the back of this manual. Inspect the battery posts and cables for tightness and corrosion. Tighten and clean as necessary. Check the battery fluid level of unsealed batteries and, if necessary, fill with DISTILLED WATER ONLY. DO NOT USE TAP WATER IN BATTERIES. Have the state of charge and condition checked. This should be done with an automotive-type battery hydrometer. NOTE: The BCI number should be located directly on the battery. DANGER batteries give off explosive hydrogen Storage gas. This gas can form an explosive mixture around the battery for several hours after charging. The slightest spark can ignite the gas and cause an explosion. Such an explosion can shatter the battery and cause blindness or other injury. Any area that houses a storage battery must be properly ventilated. Do not allow smoking, open flame, sparks or any spark producing tools or equipment near the battery. 10-4 Maint013 Rev. E 06/09 Stationary Emergency Generator Service Schedule SERVICE SCHEDULE 22 KW - 150 KW GASEOUS STATIONARY EMERGENCY GENERATOR The following is a recommended maintenance schedule for Gaseous Stationary Emergency Generator sets from 22kW to 150 kW in size. The established intervals in the schedule are the maximum recommended when the unit is used in an average service application. They will need to be decreased (performed more frequently) if the unit is used in a severe application. Use calendar time, from the previous maintenance interval to determine the next required maintenance interval. Service Maintenance Interval Information: The various service maintenance intervals are designated by interval numbers as follows: 1 An early inspection of the generator set to insure it is ready to operate when required and to identify any potential problem areas. This inspection may be performed by the end user providing the following safety steps are taken to prevent the engine from starting automatically without warning: To prevent injury, perform the following steps in the order indicated before starting any maintenance: • Disable the generator set from starting and/or connecting to the load by setting the control panel Auto/Off/ Manual switch to the “OFF” position. • Remove the 15 amp control panel fuse. • Turn off the battery charger.* • Remove the negative battery cable. * The battery charger must be turned off BEFORE removing the battery cable to prevent an over current condition from burning out sensitive control panel components and circuits. Following all maintenance, reverse these steps to insure the unit is returned to standby setup for normal operation when required. 2 A wear-in service inspection of the generator set to insure it is ready to operate and carry the load when required, and to identify any potential problem areas. Performed ONLY ONCE following the first three months or the first 30 hours of operation after purchase of the unit. This inspection contains some maintenance tasks which require special tools, equipment, and/or knowledge to accomplish and should be performed only by a Service Dealer. 3 An operational inspection of the generator set to insure it is ready to operate and carry the load when required, and to identify any potential problem areas. Performed semi-annually or following each 50 hours of operation of the unit. This inspection contains some maintenance tasks which require special tools, equipment, and/or knowledge to accomplish and should be performed only by a Service Dealer. 4 A mid-level inspection of the generator set to insure it is ready to operate and carry the load when required, and to identify any potential problem areas. Performed annually or following each 100 hours of operation of the unit. This inspection contains some maintenance tasks which require special tools, equipment, and/or knowledge to accomplish and should be performed only by a Service Dealer. 5 A comprehensive inspection of the generator set to insure it is properly serviced and ready to operate and carry the load when required, and to identify any potential problem areas. Performed annually or following each 250 hours of operation of the unit. This inspection contains some maintenance tasks which require special tools, equipment, and/or knowledge to accomplish and should be performed only by a Service Dealer. SrvSchd001 Rev. E 02/09 11-1 Stationary Emergency Generator Service Schedule Maintenance Tasks Level 1 Recommended to be done monthly/ 10 hrs. Level 2 Level 3 Task Required Task Required Comp. to be done Comp. to be done (Date- 3 months/ (DateSemiInitials) Break-in Initials) annually/ 30 hrs. 50 hrs. 1. Disable the unit from operating per the first page warning. 2. Check the engine oil level. Adjust as necessary. 3. Check the engine coolant level. Adjust as necessary. 4. Check the engine coolant thermal protection level. Correct as necessary. 5. Check the natural gas delivery system for leaks and correct pressure on gas engine driven units. Tighten connections as necessary. 6. Check the air inlets and outlets for debris. Clean as necessary. 7. Check the battery electrolyte level and specific gravity if accessible. Adjust as necessary. 8. Check the battery posts, cables, and charger for loose connections, corrosion, and proper operation. Correct as necessary. 9. Check the unit wiring for loose connections, corrosion, and damage. Correct as necessary. 11-2 Level 4 Task Comp. (DateInitials) Required to be done Annually/ 100 hrs. Level 5 Task Comp. (DateInitials) Required to be done Biannually/ 250 hrs. Task Comp. (DateInitials) SrvSchd001 Rev. E 02/09 Stationary Emergency Generator Service Schedule Maintenance Tasks Level 1 Recommended to be done monthly/ 10 hrs. Level 2 Level 3 Task Required Task Required Comp. to be done Comp. to be done (Date- 3 months/ (DateSemiInitials) Break-in Initials) annually/ 30 hrs. 50 hrs. Level 4 Task Comp. (DateInitials) Required to be done Annually/ 100 hrs. Level5 Task Comp. (DateInitials) Required to be done Biannually/ 250 hrs. Task Comp. (DateInitials) 10. Check the engine accessory drive belts and fan coupling device if equipped for correct tension, wear, weather cracking, and damage. Replace as necessary. 11. Check the engine valve clearance/ lash. Adjust as necessary.** 12. Visually inspect the unit looking for leaks, wear or damage, loose connections or components, and corrosion. Correct as necessary. 13. Test the engine and transfer switch safety devices. Correct and/or adjust as necessary. 14. Initiate an automatic start and transfer of the unit to site load and exercise it for at least 1 hour looking for leaks, loose connections or components, and abnormal operating conditions. Correct as necessary. 15. Replace the engine accessory drive belts. 16. Check gearbox oil level (if equipped). 17. Change gearbox oil (if equipped). ** Not required for engines equipped with hydraulic lifters. See the "Specification" section for lifter type. SrvSchd001 Rev. E 02/09 11-3 Stationary Emergency Generator Service Schedule Maintenance Tasks Level 1 Recommended to be done monthly/ 10 hrs. Level 2 Level 3 Task Required Task Required Comp. to be done Comp. to be done (Date- 3 months/ (DateSemiInitials) Break-in Initials) annually/ 30 hrs. 50 hrs. 18. Start and exercise the unit at full rated load (use a load bank if the site load is not enough) for at least 2 hours looking for leaks, loose connections or components, and abnormal operating conditions. Correct as necessary. 19. Perform an engine oil analysis (send a sample to a lab for results). Change the engine oil and filters if the analysis results indicate this is required. 20. Change the engine oil. 21. Replace the engine oil filter(s). 22. Replace engine spark plugs. Clean and re-gap or replace as necessary. 23. Replace the engine air filter(s). 24. Perform a 5 minute no-load operational run of the unit looking for any post service problems. 25. Return the unit to standby setup for operation when required. 11-4 Level 4 Task Comp. (DateInitials) Required to be done Annually/ 100 hrs. Level5 Task Comp. (DateInitials) Required to be done Biannually/ 250 hrs. Task Comp. (DateInitials) SrvSchd001 Rev. E 02/09 Stationary Emergency Generator Troubleshooting TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION Engine won’t crank. 1. 15 amp fuse blown. 2. Loose or corroded or defective battery cables. 3. Defective starter contactor. 4. Defective starter motor. 5. Dead or Defective Battery. 6. 5 amp fuse blown. 1. Replace fuse. 2. Tighten, clean or replace battery cables as necessary. 3. Replace contactor.* 4. Replace starter motor.* 5. Remove, change or replace battery. 6. Replace fuse.* Engine cranks but won't start 1. Out of fuel. 2. Fuel solenoid (FS) is defective 3. Open Wire #14A from Engine Control circuit board. 4. Spark plugs defective. 5. Door on tank not closed. 1. Replenish fuel. 2. Replace solenoid.* 3. Reconnect wire. Engine starts hard, runs rough. 1. Flame arrestor (air cleaner) plugged or damaged. 2. Plugged fuel line. 3. Defective spark plugs. 4. Fuel pressure incorrect. 1. Clean or replace as needed. 2. Unclog fuel line. 3. Clean, regap or replace plugs. 4. Confirm fuel pressure to regulator is as recommended in SPECIFICATIONS. Engine starts then shuts down. 1. 2. 3. 4. 5. 6. 7. AUTO/OFF/MANUAL Switch at OFF, engine continues to run 1. Defective AUTO/OFF/MANUAL switch 2. Open/disconnected wire #15A between AUTO/OFF/MANUAL switch and Control Module circuit board. 3. Defective Control Module circuit board 3. Replace board.* 1. 2. 3. 4. 5. 1. 2. 3. 4. 5. Check main line circuit breaker. Check circuit breaker & fuses. Transfer switch set to NORMAL position Generator internal failure. Thermal circuit breaker open. 1. 2. 3. 4. 5. 6. 7. Check oil and add oil as needed. Check cooling system for leaks. Replace switch.* Replace switch.* Replace board.* Repair leak - Add coolant. Replace Switch.* 1. Replace switch.* 2. Reconnect/close wire. Reset to ON or CLOSED. Reset and replace, if necessary. Set to GENERATOR position. * Auto-reset - Wait 5 min. and attempt restart. *Contact the nearest Authorized Dealer for assistance. 12-1 Trblsht001 Rev. A 10/08 No AC output from generator. Engine oil level is low. Engine is overheated. Defective Low Oil Pressure Switch Defective Coolant Temperature Switch Defective Control Module circuit board. Coolant Level is Low. Defective Low Coolant Level Switch 4. Clean, regap or replace plugs. 5. Close door on tank. Stationary Emergency Generator Notes 1 2 3 4 5 6 7 8 9 10 11 084918D 084427 049813 022097 057822 022473 042568 050967 0C4905 0A6283 044117 1 1 2 4 4 4 4 1 1 1 1 HEATER BLOCK 2000W 240V BRACKET HEATER W/WELDNUTS NUT HEX M6 X 1.0 G8 YEL CHR WASHER LOCK M6-1/4 CLAMP HOSE #8 .53-1.00 WASHER FLAT 1/4-M6 ZINC SCREW HHC M6-1.0 X 20 G8.8 HOSE COOL 5/8 ID 20R3 (24” LG) BARBED EL 45 3/8 NPT X 5/8 OD HOSE PREFORMED BLOCK HEATER BARBED STR 3/8 NPT X 5/8 1 2 3 4 5 6 7 8 9 (1) 10 11 12 13 14 15 (2) 16 (2) 17 18 19 20 21 22 23 24 25 26 (4) 27 28 29 30 31 32 33 34 35 36 37 (3) 38 39 0F3137 0F3135 0F3136 023484N 0F4677 067617030A 067617030B 043180 022264 0C3990 057701 022155 0C2428 0F3618 0A9457 057073 0D5466 0A7822 022237 022241 049226 0C2266 0C2454 042568 022473 022097 049813 0E9764 0G6962B 025433 024469 067210A 0D6029 051713 081008 077043J 0F6156 029289 0F3113 047411 036943 1 1 1 1 1 4 6 6 REF. 2 2 1 1 2 REF. REF. 2 2 6 6 8 4 12 8 4 6” 1 1 1 1 4 2 1 3 1 A/R REF 4 2 PAN CB CONN BOX STAND RH CONTROL STAND LH CONTROL BUSHING SNAP SB-2.5-31 ASSY PCB INTERFACE 1PH 240V INTERFACE 3PHS 416/480V INTERFACE 3PHS 208/240V WASHER FLAT M4 WASHER LOCK #8-M4 SCREW PHTT M4-0.7 X 10 ZYC BLOCK TERM 20A 8 X 6 X 1100V WASHER LOCK #6 SCREW PHTT #6-32 X 1/2 ZYC DECAL CPL CUST CONN H CTRL DECAL NEUTRAL JUNCTION BLOCK 3/8-16 BUS BAR NEUTRAL BLOCK 390 LUG SLDLSS 600/250-1/0 X 1/4-28 WASHER LOCK 3/8 NUT HEX 3/8-16 STEEL WASHER LOCK M5 SCREW PHTT M5-0.8 X 16 ZYC SCREW THF M6-1 X 16 N WA Z/JS SCREW HHC M6-1.0 X 20 G8.8 WASHER FLAT 1/4-M6 ZINC WASHER LOCK M6-1/4 NUT HEX M6 X 1.0 G8 YEL CHR RAIL SNAPTRACK PCB HOLDER BULK ASSY RELAY PCB 12VDC LUG SLDLSS #6-14 X 13/64 CU SCREW HHTT #10-32 X 3/8 CZ DECAL GROUND LUG SCREW HHTT M6-1.0 X 16 ZYC WASHER FLAT M5 GROMMET 1.25 X .25 X .75 CONDUIT FLEX 2.0" ID PLATE WIRE SNGL GALV TAPE ELEC 1/2 FOAM (AS REQ’D) ASSY PCB HSB CTRL IGN MODULE SCREW HHC M6-1.0 X 16 G8.8 SCREW PPHM #10/32 X 2 40 41 42 43 44 45 023897 022152 022158 0F8565 045764 023762 A C 0F4810 0D5556 0D5566 0D5568 0D9693 0F0492 048927 023897 022152 022158 0C2454 029289 0F1733 UL CIRCUIT BREAKER (ED) 1 COVER ED CB STAND C3 1 CB 0090A 3P 480V S ED4 LL CB 0060A 3P 600V S ED6 LL CB 0080A 3P 600V S ED6 LL CB 0125A 3P 480V S ED4 LL 1 INSULATOR CB S (ED-3P) 4 SCREW RHM #10-32 X 4-1/2 4 WASHER FLAT #10 ZINC 4 WASHER LOCK #10 4 NUT HEX #10-32 STEEL 7 SCREW THF M6-1 X 16 N WA Z/JS 1 TAPE ELEC 1/2 FOAM (AS REQ’D) 1 DECAL CUSTOMER CONNECT INSIDE D E F G H J K L 0F4811 0D5573 0D5574 0D5576 0F0199 065960 022473 022097 022127 0C2454 029289 0F1733 UL CIRCUIT BREAKER (FD) 1 COVER FD CB STAND C3 CB 0175A 3P 600V S FD6 LL CB 0200A 3P 600V S FD6 LL CB 0250A 3P 600V S FD6 LL 1 INSULATOR CB FD FRAME 30MIL 4 SCREW SHC 1/4-20 X 4 G8.8 NZ 4 WASHER FLAT 1/4-M6 ZINC 4 WASHER LOCK M6-1/4 4 NUT HEX 1/4-20 STEEL 7 SCREW THF M6-1 X 16 N WA Z/JS 1 TAPE ELEC 1/2 FOAM (AS REQ’D) 1 DECAL CUSTOMER CONNECT INSIDE A C D E F G H J K L 0F4812 0D5577 0F2353 022770 022473 022097 022127 0C2454 029289 0F1733 UL CIRCUIT BREAKER (JD+LD) 1 COVER JD/LD CB STAND C3 1 CB 0300A 3P 600V S JD6 LL 2 INSULATOR CIRCUIT BR. JD/LD 4 SCREW RHM 1/4-20 X 3 4 WASHER FLAT 1/4-M6 ZINC 4 WASHER LOCK M6-1/4 4 NUT HEX 1/4-20 STEEL 7 SCREW THF M6-1 X 16 N WA Z/JS 1 TAPE ELEC 1/2 FOAM (AS REQ’D) 1 DECAL CUSTOMER CONNECT INSIDE 1) D E F G H J K L 2) A C 3) 3 2 2 1 1 1 WASHER FLAT #10 ZINC WASHER LOCK #10 NUT HEX #10-32 STEEL DECAL H-100 RB3 CUST CONN SCREW HHTT M4-0.7 X 8 ZP WASHER SHAKEPROOF EXT #10 STL (1) ITEM INCLUDED WITH HARNESS (2) ITEM INCLUDED WITH 0D5464B (3) ITEM IS PART OF 9R. (4) ITEM IS PART OF 5R. 4.) A C D E F G H J K L M N P R S T U V W (1) X Y 0F8453 0F4165$ 0F4186 036261 053640 038150 022264 022471 029289 0F1733 022129 0F8432 0C2454 0F8451 049897 022145 045771 0F8843 W/CB 0G3259 058306 UL CIRCUIT BREAKER (225AF) 1 COVER CB C3 225AF REF CIRCUIT BREAKERS 200A FRAME 1 COVER CB DISH 225AF 4 RIVET POP .125 X .275 SS 8 SCREW RHM #8-32 X 3-1/4 4 WASHER FLAT #8 ZINC 4 WASHER LOCK #8-M4 4 NUT HEX #8-32 STEEL 2 TAPE ELEC 1/2 FOAM 1 DECAL CUSTOMER CONNECT INSIDE 9 WASHER LOCK M8-5/16 1 INSULATOR CB 225AF 7 SCREW THF M6-1 X 16 N WA Z/JS 3 LUG SLDLSS 300 MCM-6 AL/CU 6 SCREW SHC M8-1.25 X 20 G8 6 WASHER FLAT 5/16-M8 ZINC 3 NUT HEX M8-1.25 G8 CLEAR ZINC 3 BUS BAR 200A LUG ADAPTOR 2 TERMINAL COVER CB 1 DECAL TERMINAL SHOCK HZD BI 3 SCREW SHC M8-1.25 X 25 G12.9 5.) A C D E F G H J K L M N P R S (1) T U (2) V (2) W 0F8454 0F4166$ 0F1733 042419 023897 022152 022158 0C2454 029289 052647 046526 W/CB 0A7822 022131 W/CB 023334 W/CB W/CB 0G3259 UL CIRCUIT BREAKER (400AF) 1 COVER CB C3 400AF REF CIRCUIT BREAKERS 400A FRAME 1 DECAL CUSTOMER CONNECT INSIDE 4 SCREW RHM 10-32 X 4 4 WASHER FLAT #10 ZINC 4 WASHER LOCK #10 4 NUT HEX #10-32 STEEL 7 SCREW THF M6-1 X 16 N WA Z/JS 1 TAPE ELEC 1/2 FOAM 3/2 SCREW SHC M10-1.5 X 25 G12.9 3/2 WASHER LOCK M10 3 BUS BAR CB ADAPTER 225-400 A 3 LUG SLDLSS 600/250-1/0 X 1/4-28 3 WASHER FLAT 3/8-M10 ZINC 2 TERM COVER CB 6 SCREW HHC 1/4-28 X 1/2 G5 3/2 SCREW SHC M10-1.5 X 25 G12.9 3/2 WASHER LOCK M10 1 DECAL TERMINAL SHOCK HZD BI 6.) A B C D E F G H 0D5466 039287 022145 022129 045771 045335 022097 0A7822 NEUTRAL BLOCK 390 / 200-400A 2 BUS BAR NEUTRAL BLOCK 390 1 SCREW HHC M8-1.25 X 45 G8.8 FT 1 WASHER FLAT 5/16-M8 ZINC 1 WASHER LOCK M8-5/16 1 NUT HEX M8-1.25 G8 YEL CHR 2 SCREW HHC 1/4-28 X 3/4 G5 2 WASHER LOCK M6-1/4 1 LUG SLDLSS 600/250-1/0X1/4-28 (1) HARDWARE FOR MTG. CB TERMINAL COVERS IS SUPPLIED WITH CIRCUIT BREAKERS. (2) 3/2 QTY. 3 POLE & 2 POLE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 * 0F3182 0F6194 0G0993 0G0998 0G0991 0G0997 0F3183 0F6195 0F6203 0G0994 0G0996 0G1000 0G1048 0G1049 0G0992 0G0995 0G0999 0G1094 0G1095 068405C 087272 072878 0C9708 0F3726B 0C2454 023454 0F8408 046526 0A2601 072879 052646 043123 051779 092950 04576100CJ 022155 0C2428 023484N 022392 052259 051769 0E7230 0F3033 0F2722 083549 020151 023365 033133 033143 086032 090063 090064 090152 022661L 028739A 085662D 068113A 068406 0F6834 023484N 052624 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 REF 1 9 1 4 4 1 1 4 4 4 1 4 2 2 1 2 2 3 3 1 1 4 1 3 1 2 2 1 1 1 1 2 1 1 1 1 1 1 ROTOR 390 70AB3 CPL ROTOR 390 70KB3 CPL ASSY RTR 390 45AB3 CPL ASSY RTR 390 45KB3 CPL ASSY RTR 390 55KB3 CPL ASSY RTR 390 55AB3 CPL STATOR 390 70AB3 CPL STR 390 70KB3 CPL STR 390 70GB3 CPL ASSY STR 390 45GB3 CPL ASSY STR 390 45KB3 CPL ASSY STR 390 45AB3 CPL ASSY STR 390 45JB3 CPL ASSY STR 390 45 LB3 CPL ASSY STR 390 55GB3 CPL ASSY STR 390 55KB3 CPL ASSY STR 390 55AB3 CPL ASSY STR 390 55JB3 CPL ASSY STR 390 55LB3 CPL EXITER FIELD 2"LG SPD CONN ASSY EXCITER 2.00" STK KEY SQ 3/8 X 3-1/4 STEEL INSTR HYPOT TEST (NOT SHOWN) ASSY FLYWHEEL CPL SCREW THF M6-1 X 16 N WA Z/JS KEY WOODRUFF #E SCREW HHC M10-1.50 X 16 G10.9 WASHER LOCK M10 SCREW HHC M16-2.0 X 45 G8.8 SPACER .69 X 2.75 X .37 ST/ZNC WASHER FLAT M14 WASHER LOCK M14 NUT HEX M14-2.0 G8 YEL CHR COLLAR SLIP FIT 390 MM STUD M14-2.0 X 650 G5 ZINC WASHER LOCK #6 SCREW PHTT #6-32 X 1/2 ZYC BUSHING SNAP SB-2.5-31 PIN DOWEL 1/2 X 1-1/4 WASHER FLAT M12 WASHER LOCK M12 SCREW HHC M12-1.75 X 80 G10.9 SHIELD ALT EXCITER 390 COVER EXCITER SHIELD SLEEVE RUBBER CLAMP VINYL .312 X .203 Z WASHER SHAKEPROOF INT #8 SCREW HHM #8-32 X 3/8 SCREW HHM #8-32 X 7/8 LUG RT-ANG #10/10-12 BRIDGE SUPPORT DIODE 15" CAP END ROTOR 390MM ASSY BRIDGE RECTIFIER SLEEVING UL #0 .330 ID (3” LG) TIE WRAP UL 3.9" X .10" BLK TIE WRAP UL 17.7 X .35 BLK HT REAR BEARING CARRIER CPL SCREW HHC M12-1.75 X 60 G10.9 MOUNT CT'S 5.4L & 6.8L BUSHING SNAP SB-2.5-31 BEARING BALL 6212 SEALED * ROTOR REPLACEMENT PARTS. ** PARTS INCLUDED WITH TRANSFORMER. 1 2 3 4 5 6 7 8 9 10 11 12 13 16 17 18 19 20 21 22 23 24 25 0F3150 065852 052252 052257 052259 055597 052251A 052860 0F2895 045764 057192 090502 061383 043107 057192 022131 046526 0536210410 042909 022261 022129 022145 045771 0F2910 0F2895 1 1 4 4 4 4 4 4 1 1 4 4 1 1 4 8 8 1 1 2 1 2 2 1 1 BASE CP 6.8L70KW/5.4L 55KW DD SPRING CLIP HOLDER .37-.62 DAMPENER VIBRATION SPACER .49 X .62 X 1.87 PWDR/ZINC WASHER FLAT M12 SCREW HHC M12-1.75 X 85 G8.8 DAMPENER VIBRATION 50 WHITE NUT LOCKING M12-1.75 SUPPORT ENG 5.4L LH/RH 6.8L RH SCREW HHTT M4-0.7 X 8 BP SCREW SHC M10-1.5 X 30 G12.9 (5.4L) SCREW SHC M10-1.5 X 60 G12.9 (6.8L) LUG SOLDERLESS 3/0-#4 X 13/32 CU SCREW HHC M8-1.25 X 25 G8.8 SCREW SHC M10-1.5 X 30 G12.9 WASHER FLAT 3/8-M10 ZINC WASHER LOCK M10 ASSY WIRE 14.00” SCREW HHC M8-1.25 X 30 G8.8 WASHER SHAKEPROOF INT 3/8 WASHER LOCK M8-5/16 WASHER FLAT 5/16-M8 ZINC NUT HEX M8-1.25 G8 YEL CHR SUPPORT, ENGINE (6.8L LH SIDE) SUPPORT ENG (5.4L LH SIDE) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 0F3408 0F3411 058208 022131 050331A 050331 038805T 038804Y 045771 022129 027482 075763 0C2454 0F3409 1 1 1 1 1 1 1 1 1 1 1 1 8 1 TRAY BATTERY STRAP BATTERY RETAINMENT BATT 12VDC 24F 625 WASHER FLAT 3/8-M10 ZINC BATT POST COVER RED + BATT POST COVER BLK CABLE BATT BLK #1 X 40.00 CABLE BATT RED #1 X 35.00 NUT HEX M8-1.25 G8 YEL CHR WASHER LOCK M8-5/16 WASHER SHAKEPROOF EXT 5/16 STL BOOT BATTERY CABLE SCREW THF M6-1X16 N WA Z/JS SUPPORT BATTERY TRAY 1 2 3 4 5 6 7 8 9 10 11 0D2513D 0F5419 0F4268 0F4270A 0F6977 037561 047411 022097 049811 0F4269 022473 1 1 1 1 1 1 4 4 4 1 1 AIR CLNR BTM PLT W/CPLR 8.1L ELEMENT AIR FILTER TOP PLATE VENTURI HOLD DOWN AIR CLEANER PLATED PLATE AIR CLEAN TOP 5.4L/6.8L NUT WING 1/4-20 NYLK SCREW HHC M6-1.0 X 16 G8.8 WASHER LOCK M6-1/4 WASHER FLAT M6 GASKET MIXER BODY WASHER FLAT 1/4-M6 ZINC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 * 32 33 34 35 36 37 38 39 0F3144 035685 0F2857A 0F4168 0F4169 0E7854 0F2820 051756 046526 022131 052250 0F4412 0F4412A 039253 022129 022097 0C8566 0F4765 089685 0F5589 0C2454 055596 0C7649 069860E 045764 065852 080712 076749 048031C 069811 0F4770 089514 0E2507 0H1827 0F4767 090283 0F2776A 022145 022132 1 4 1 1 1 1 1 4 4 4 2 1 1 8 8 8 8 1 1 2 11 1 1 1 1 1 1 1 1 REF 1 1 1 1 1 1 1 8 1 W ELDMENT RAD SUPPORT C3 (22" ) CLAMP HOSE #28 1.32-2.25 RADIATO R 581 X 585 X 70 CPL LH HOSE UPPER RADIATOR C3 HOSE LOWER RADIATOR C3 CLUTCH CO OLING FAN FAN 22" DIA 10 BLADE SCREW HHC M10- 1.5 X 20 G 8.8 W ASHER LOCK M10 W ASHER FLAT 3/8-M10 ZINC TAPE FOAM 1 X 1 (23” LG) SPACER FAN 6.8L SPACER FAN 5.4L SCREW HHC M8-1.25 X 20 G 8.8 W ASHER LOCK M8-5/16 W ASHER LOCK M6-1/4 SCREW HHFC M6-1.0 X 20 G8.8 FTG CMPN BLKHD 3/8" OD TUBE BRS GROMMET .75 X .12 X .50 GUARD FAN C3 CPL SCREW THF M6-1 X 16 N WA Z/JS BARBED STR 3/8 NPT X 3/8 CLAMP HOSE .38-.87 HOSE DRAIN ASSY 28" SCREW HHTT M4-0.7 X 8 BP SPRING CL IP HOLDER .37-.62 BRKT CO OLANT RECOVERY TANK TANK CO OLANT RECOVERY CLAMP HOSE BAND 1/4 CAP HEX 1/4 NPT BRASS TUBE FAN CLUTCH PREHTR LOWR C3 FTG CMPR 3/8TUBE X 3/8 NPT W/FERL PROBE COOLANT LEVEL 3/8NPTF (USE WITH HARN P/N 0F5990 & 0F5991) PROBE COOLANT LEVEL 3/8- 18NPT F ( USE W ITH HARN P/N 0H2595 & 0H3072) TUBE FAN CLUTCH PREHTR UPPR C2 CAP RADIATO R 13 PSI BRACKET SIGNAL CONDIT IO NER W ASHER FLAT 5/16-M8 ZINC W ASHER FLAT 9/16 ZINC * ITEM 31 IS INCLUDED WITH ITEM 25. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 21 22 0F3224 0F3224A 0F3231 0F3231A 0F2808B 0A6765 0F4710 0F7200 080762 0F2809 0F2981A 0F2962 047411 022097 0F2830 0F4505 022473 0F2773D 0F2773E 088775 0F5447 0F6166 * 0F6166 ** 0F6166A ** 0C9748 1 1 1 1 2 2 6 6 10 1 2 2 4 4 2 2 4 2 2 6 1 2 1 1 1 NOTES: * 6.8L ONLY ** 5.4L ONLY PIPE EXH MANIFOLD 6.8L C3 RH (6.8L 70KW) PIPE EXH MANIFOLD 5.4L C3 RH (5.4L 55KW) PIPE EXH MANIFOLD 6.8L C3 LH (6.8L 70KW) PIPE EXH MANIFOLD 5.4L C3 LH (5.4L 55KW) PIPE EXHAUST MUFFLER OUT RING GASKET, 2.5DIA WASHER LOCK M10 SS SCREW HHC M10-1.5 X 50 SS FTH BOLT U 3/8-16 X 2.62 PIPE EXHAUST CROSSOVER MFLR 7" X 9" X 25" (2) 2.5" IN/2.5" OUT MUFFLER STRAP SCREW HHC M6-1.0 X 16 G8.8 WASHER LOCK M6-1/4 MUFFLER BRACKET STIFFENER GLASS PACK 23.5" LG 2.5" IN/OUT WASHER FLAT 1/4-M6 ZINC EXHAUST BLANKET 800MM LG (6.8L 70KW) EXHAUST BLANKET 750MM LG (5.4L 55KW) WASHER FLAT 3/8 SS BRKT MUFFLER PIPE LH MUFFLER SIDE PIPE LH MUFFLER SIDE PIPE RH MUFFLER SIDE PLUG M18-1.50 (1) 1 (1) 2 3 4 (2) 5 (1) 6 7 8 9 10 11 (1) 12 0F3883 0F1960 0F2842 0F2843 0D5419 0F2849 0D3488G 0D3488L 0D3488K 057795A 059057 0F2844 0F2847 0F2839 1 1 8 1 1 1 1 1 1 1 1 1 1 1 TUBE HEATER WATER ENGINE 5.4L FORD IGNITION COIL ASSY FORD GASKET THERMOSTAT HOUSING FORD OIL FILTER FORD V-10 ENGINE TUBE OIL LEVEL INDICATOR FORD BELT SERPENTINE 65.0" (1800 RPM) SERPENTINE BELT (66.0") (2650 RPM) SERPENTINE BELT (68.3") (3600 RPM) BARBED EL 90 3/4 PLASTIC HOSE 3/4 ID SAE-30R2 (16.75”LG) THERMOSTAT ASSY FORD PULLEY FAN BELT FORD GASKET INTAKE MANIFOLD RIGHT (1) 13 (1) 14 15 16 (1) 17 18 19 20 21 22 23 24 25 26 27 28 29 30 (4) 31 32 33 (1) 34 (1) 35 (1) 36 (1) 37 (1) 38 (1) 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 (4)(3) 55 56 57 58 59 (1) 60 0F2840 0F1959 035579 0F2851 0F2848A 055440 022097 022473 042568 022129 0F4612 0E9868A 022145 057796 0F3216 0F3216B 0F3216D 0F3217 0F3287 0F3017 0F5991 0H3072 1 1 1 1 1 8 3 3 3 6 1 1 7 1 1 1 1 1 1 1 1 1 051713 042914 051731 022129 022145 051756 046526 022131 039253 064416 022131 046526 0D8027 0D8025 0D8026 0D8030 0F2846 0D8029 0D8028 0F2776A 045772 045771 0E0992A 057823 029333A 0F6151 0E0502 0F4308 036277 0H0550 8 2 9 9 9 2 2 2 3 1 2 1 4 2 3 1 1 1 1 2 1 2 8 3 2 2 1 1 1 1 GASKET INTAKE MANIFOLD LEFT INTAKE MANIFOLD 5.4L (PLASTIC) BSHG RDCR HEX 1/4 TO 1/8 CONNECTION WATER OUTLET FORD REWORK DIPSTICK 5.4L 27.75" SCREW HHC M5-0.8 X 25 G8.8 WASHER LOCK M6-1/4 WASHER FLAT 1/4 ZINC SCREW HHC M6-1.0 X 20 G8.8 WASHER LOCK M8-5/16 SENDER OIL PRESSURE 1/8"NPT ALTERNATOR DC W/OUT PULLEY WASHER FLAT 5/16 ZINC GROMMET PULLEY 80 OD DC ALTERNATOR (1800RPM) PULLEY 117 OD DC ALTERNATOR (2650 RPM) PULLEY 160 OD DC ALTERNATOR (3600 RPM) SPACER DC ALTERNATOR PULLEY BRKT DC ALTERNATOR UPPER BRKT DC ALTERNATOR LOWER HARN ENG 5.4L H-100 (USE WITH PROBE P/N 0E2507) HARN ENG G5.4L G3 H-100 CPL (USE WITH PROBE P/N 0H1827) WASHER FLAT M5 SCREW HHC M8-1.25 X 90 G8.8 SCREW HHC M8-1.25 X 50 G8.8 WASHER LOCK M8-5/16 WASHER FLAT 5/16-M8 ZINC SCREW HHC M10-1.5 X 20 G8.8 WASHER LOCK M10 WASHER FLAT 3/8-M10 ZINC SCREW HHC M8-1.25 X 20 G8.8 SCREW HHC M10-1.5 X 45 G8.8 FT WASHER FLAT 3/8-M10 ZINC WASHER LOCK M10 SCREW WP PULLEY M8-1.25 X 19 BOLT HEX FL HD M8-1.25 X 28 BOLT HEX FL HD M8-1.25 X 31 TENSIONER ENG. AUTOMATIC BELT PULLEY WATER PUMP FORD (1800RPM) PULLEY ENGINE WATER PUMP (2650 & 3600RPM) PULLEY GROOVED ENGINE IDLER BRACKET SIGNAL CONDITIONER NUT HEX M10-1.5 G8 YEL CHR NUT HEX M8-1.25 G8 YEL CHR PLUG EXPANSION 14 OD CLAMP HOSE #10 .56-1.06 TIE WRAP UL 7.4" X .19" BLK CAP RUBBER TEMPERATURE SENDER, DELPHI BRACKET DC ALT STABILIZER ELBOW 90D STREET 1/8 DECAL EPA STATIONARY EMERGENCY (1) NOTE: PART OF ENGINE MAKE P/N 0F3902. (2) NOTE: I/N 5 IS PART OF I/N 2. (3) NOTE: I/N 55 IS FOR HOLDING SENSOR TO I/N 50. (4) NOTE: NOT SHOWN 1 2 3 4 5 6 7 8* 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 41 42 43 0D9913 0G7461 0F3514 0F9965C 0F9965C 0F2776A 0D5417 0F3844 029333A 022131 055596 057772 057823 057765 0F3534 069860E 049821 022129 039253 0D2244M 044118 055934M 047411 071623 0G1818 022097 0F1820 0F1818 022473 048031J 0F2929 077996 046526 070008 070006 0D2608 0F5114 0F5454 047290 059057 040173 16 1 1 1 2 1 8 8 1 1 1 1 2 1 2 1 2 4 1 1 REF 1 1 4 1 1 2 2 1 1 1 2 6 8 24 8 1 1 1 1 1 SCREW SHC M8-1.25 X 35 SS STARTER MOTOR 12V SPACER FLEXPLATE 5.4L/6.8L (1800 RPM ONLY) FLEX PLATE 2 POLE 5.4L/6.8L (1800 RPM UNITS ONLY) FLEX PLATE 2 POLE 5.4L/6.8L (3600 RPM UNITS ONLY) BRACKET, SIGNAL CONDITIONER SCREW HHC M10-1.0 X 25 G10.9 WASHER FLAT .43 X 1.00 TIE WRAP UL 7.4" X .19" BLK (NOT SHOWN) WASHER FLAT 3/8-M10 ZINC BARBED STR 3/8 NPT X 3/8 WASHER NYLON .565 CLAMP HOSE #10 .56 - 1.06 ADAPTER M14-1.50 X 3/8 NPT HEAT SHLD EXHAUST MANIFOLD HOSE DRAIN ASSY 28" SCREW SHC M8-1.25 X 30 G12.9 WASHER LOCK M8-5/16 SCREW HHC M8-1.25 X 20 G8.8 ASSY MAGPICKUP(3/8-24 MALE) BARBED STR 1/2 NPT X 5/8 CLAMP VINYL .75 X .343 Z SCREW HHC M6-1.0 X 16 G8.8 SCREW SHC M10-1.5 X 55 G12.9 VALVE PCV G3 WASHER LOCK M6-1/4 MACHINED MANIFOLD EXHAUST 5.4L GASKET EXHAUST MANIFOLD WASHER FLAT 1/4-M6 ZINC HOSE CLAMP BAND 5/8" ENGINE ADAPTER 5.4L/6.8L CAP HOSE WASHER LOCK M10 WASHER FLAT M8 SS WASHER LOCK M8 SSTL SCREW HHC 5/16-18 X 1/2 SSTL DECAL REFER TO OWNERS MANUAL PLATE MAG PICK-UP ADAPTOR HOSE 3/8 ID SINGLE BRAID (15” LG) HOSE 3/4 ID SAE-30R2 CLAMP HOSE #5.5 .62-.62 * NOTE: I/N 8 IS FOR HOLDING SENSOR TO I/N 5. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 0F3224 0F3224A 0F3231 0F3231A 0F5447 0A6765 0F4710 0F7200 080762 0F2809 0F2981A 0F2962 047411 022097 0F2830 0D3159 022473 0F2773D 0F2773E 088775 0F6166 * 0F6166 ** 0F6166A ** 1 1 1 1 1 2 6 6 6 1 2 2 4 4 2 1 4 2 2 6 2 1 1 NOTES: * 6.8L ONLY ** 5.4L ONLY PIPE EXH MANIFOLD 6.8L C3 RH (6.8L 70KW) PIPE EXH MANIFOLD 5.4L C3 RH (5.4L 55KW) PIPE EXH MANIFOLD 6.8L C3 LH (6.8L 70KW) PIPE EXH MANIFOLD 5.4L C3 LH (5.4L 55KW) BRKT MUFFLER RING GASKET, 2.5DIA WASHER LOCK M10 SS SCREW HHC M10-1.5 X 50 SS FTH BOLT U 3/8-16 X 2.62 PIPE EXHAUST CROSSOVER MFLR 7" X 9" X 25" (2) 2.5" IN/2.5" OUT MUFFLER STRAP SCREW HHC M6-1.0 X 16 G8.8 WASHER LOCK M6-1/4 MUFFLER BRACKET STIFFENER FLANGE EXHAUST WASHER FLAT 1/4-M6 ZINC EXHAUST BLANKET 800MM LG (6.8L 70KW) EXHAUST BLANKET 750MM LG (5.4L 55KW) WASHER FLAT 3/8 SS PIPE LH MUFFLER SIDE PIPE LH MUFFLER SIDE PIPE RH MUFFLER SIDE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31(1) 32 33 34 35 36 37 38 0F3144 035685 0F2857A 0F4168 0F4169 0E7854 0F2820 051756 046526 022131 052250 0F4412 0F4412A 0F8651 022129 022097 0C8566 0F4765 089685 0F2776A 0C2454 055596 0C7649 069860E 045764 065852 080712 076749 048031C 069811 0F4770 089514 0E2507 0H1827 0F4767 090283 022145 022132 1 4 1 1 1 1 1 4 4 4 2 1 1 8 8 8 8 1 1 1 11 1 1 1 1 1 1 1 1 REF 1 1 1 1 1 1 8 1 WELDMENT RAD SUPPORT C3 (22" ) CLAMP HOSE #28 1.32-2.25 RADIATO R 581 X 585 X 70 CPL LH HOSE UPPER RADIATOR C3 HOSE LOW ER RADIATOR C3 CLUTCH CO OLING FAN FAN 22" DIA 10 BLADE SCREW HHC M10-1.5 X 20 G 8.8 WASHER LOCK M10 WASHER FLAT 3/8-M10 ZINC TAPE FOAM 1 X 1 (23” LG) SPACER FAN 6.8L SPACER FAN 5.4L SCREW HHFC M8-1.25 X 20 W/M6 WASHER LOCK M8-5/16 WASHER LOCK M6-1/4 SCREW HHFC M6-1.0 X 20 G8.8 FTG CMPN BLKHD 3/8" OD TUBE BRS GROMMET .75 X .12 X .50 BRACKET SIGNAL CONDIT IO NER SCREW THF M6-1 X 16 N W A Z/JS BARBED STR 3/8 NPT X 3/8 CLAMP HOSE .38-.87 HOSE DRAIN ASSY 28" SCREW HHTT M4-0.7 X 8 BP SPRING CL IP HOLDER .37-.62 BRKT CO OLANT RECOVERY TANK TANK CO OLANT RECOVERY CLAMP HOSE BAND 1/4 CAP HEX 1/4 NPT BRASS TUBE FAN CLUTCH PREHTR LOWR C3 FTG CMPR 3/8TUBE X 3/8 NPT W/FERL PROBE COOLANT LEVEL 3/8 NPTF (USE WITH HARN P/N 0F 5990 & 0F5991) PROBE COOLANT LEVEL 3/8-18NPT F (USE WITH HARN P/N 0H2595 & 0H3072) TUBE FAN CLUTCH PREHTR UPPR C2 CAP RADIATO R 13 PSI WASHER FLAT 5/16-M8 ZINC WASHER FLAT 9/16 ZINC ( 1) ITEM 31 IS INCLUDED WITH ITEM 25. 1 2 3 4 5 6 7 8 9 10 0G16140GS0R 0G16150GS0R 0G15300GS0R 0G16130GS0R 0D3215B 0C2454 022097 049813 0C2634A 047411 2 2 1 1 2 32 1 1 1 1 PANEL C3 FRONT SIDES PANEL C3 REAR SIDES PANEL LOWER FRONT PANEL C3 TOP ACCESS COVER 160 X 170 GALV SCREW THF M6-1 X 16 N WA Z/JS WASHER LOCK M6-1/4 NUT HEX M6 X 1.0 G8 YEL CHR ASSY ACCESS COVER SCREW HHC M6-1.0 X 16 G8.8 1 2 3 4 5 6 7 8 0G17420GS0R 0G17390GS0R 0G17400GS0R 0G17410GS0R 056326 0C2454 056326 056326 1 1 1 1 1 22 1 1 GUARD BELT RIGHT HAND C3 GUARD BELT TOP C3 GUARD BELT BOTTOM C3 GUARD BELT LEFT HAND C3 TRIM VINYL BLACK 1/8GP (21” LG) SCREW THF M6-1 X 16 N WA Z/JS TRIM VINYL BLACK 1/8GP (10 .37” LG) TRIM VINYL BLACK 1/8GP (12” LG) COMPONENTS INCLUDED IN 0G4140E 1 ENCL H/G CONTROL PANEL 1 COVER CONTROL PANEL 1 HINGE CONTINUOUS H PANEL 7 RIVET POP .125 X .275 SS 1 ASSY PROGRAMMED H-100 1 DECAL FUSES LOCATED INSIDE 1 RAIL SNAPTRACK PCB HOLDER BULK (12”LG) 1 ASSY PCB 10A UL BATT CHRGR 12V 1 PLATE HARNESS CLAMP 1 ASSY PCB PWR AVR W/AMP HEADER 1 ASSY PCB BOSCH GOV DRIVER 1 DIO BRIDGE 25A 600V 11 WASHER LOCK M5 4 SCREW PPHM M5-0.8 X 30 SS 11 WASHER FLAT M5 6 SCREW HHPM M5-0.8 X 12 5 NUT HEX M5-0.8 G8 YEL CHR 3 WASHER FLAT M4 3 SCREW PHTT M4-0.7 X 10 ZYC 1 CONN DUST CAP W/CHAIN DB9 1 WASHER FLAT M3.5 1 SCREW PHTT M3.5-0.6 X 10 10 SCREW PPHM M4-0.7 X 8 BLX OX 10 WASHER LOCK #8-M4 1 DECAL WRN BATT CHRG 12/24V BI 1 M5-0.8 CAPTIVE PANEL KNLD HD 2 SEAL COVER 3.18 X 12.7 X 382 1 SEAL COVER 3.18 X 12.7 X 283 1 HARNESS H-PNL INTEGRATED SW (NOT SHOWN) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 0F1823CST06 0F1824AST06 0F2606 036261 0F5763 0F1732 0E9764 0F1740C 0F1958 0F2256 0E3161 029673 049226 079224 051713 0F5886 051716 043180 0C3990 0F4333 0F5883 0F5884 055014 022264 0G3546 0G3648 0F6305 0F6305A 0G4329 A B C D E 0F1263 0F1262 0F1264 0E9049B 055911 COMPONENTS INCLUDED IN WIRE HARNESS 1 ADPTR RH SIDE WICKMANN 178.6191 4 HOLDER FUSE WICKMANN 178.6150 1 ADPTR LH SIDE WICKMANN 178.6192 1 ASSY PCB G-PANEL RELAY 12VDC 1 BLOCK TERM 20A 12 X 6 X 1100V 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 056739 0F2627B 022287 022473 022097 043182 051714 052777 0C2323 0F5459 0F5461 022127 0F5460 0E7403C 0E7403B 0F6145 0C2699 0C2266 COMPONENTS NOT INCLUDED IN 0G4140E OR WIRE HARNESS 1 RELAY CONTACTOR 12VDC 1 DPE BREAKER SEE DRAWING 0F9280 1 BOOST RESISTOR SEE DRAWING 0F9280 1 COVER CONTROL PANEL SIDE 2 SCREW HHC 1/4-20 X 3/4 G5 4 WASHER FLAT M6-1/4 2 WASHER LOCK M6-1/4 3 WASHER LOCK M3 3 NUT HEX M3-0.5 G8 YEL CHR 3 WASHER FLAT M3 2 SCREW PHTT #6-32 X 5/8 ZYC 1 DECAL CPL CONTROL PANEL FUSES 1 DECAL CPL 5.4/6.8L TB3 2 NUT HEX 1/4-20 STEEL 1 DECAL CPL 5.4/6.8L RELAY BOARD 1 FUSE ATO TYPE 15 AMP (BLUE) 2 FUSE ATO TYPE 10 AMP (RED) A/R SEAL WEATHER .45"DIA 2 SCREW PHTT #6-32 X 3/8 ZYC 4 SCREW PHTT M5-0.8 X 16 ZYC (2) 1 (2) 2 (2) 3 (3) 4 (2) 5 (2) 6 (3) 7 0F58660ST01 0F58610ST01 0F58650ST01 0F58640AL01 0F58620ST01 0F58630ST01 0F58600AL01 1 4 2 2 2 1 1 REAR WRAP C3 DOOR C3 CENTER SUPPORT C3 DISCHARGE DUCT LH & RH SIDE C3 FRONT CORNERS C3 DISCHARGE CENTER DUCT C3 ROOF C3 ALUM 8 9 10 11 12 14 15 16 17 18 19 20 21 22 25 26 27 29 30 31 32 33 34 35 36 37 38 40 41 (1) 42 43 44 45 46 0C2454 0E3257 0E5968 0F3949L 0F2766 0F3185 0F3416 0F3949E 0C2634A 022473 022097 022127 0F3072 078115 0F5048D 0F5049 0F3949B 0F4073A 0F4073F 087233 0F3180 0F3635C 0F4073 0F3890B 0F4073B 0F3890A 042568 022447 049813 077992 0912970094 0F8869D 078115A 066760 40 6 1 3 3 2 2 1 1 5 1 1 12 30 4 4 3 1 1 2 1 1 4 11 1 5 4 4 4 29 4 1 10 1 SCREW THF M6-1 X 16 N WA Z/JS SCREW TH-FRM M6 W/CAP SHKPRF W GASKET EXTRUDED TRIM (547” LG) INSULATION SPLITTER SML SPLITTER STRINGER SPLITTER C3 SUPPORT SPLITTER C5 130KW INSULATION ROOF TOP REAR ASSEMBLY COVER ACCESS WASHER FLAT 1/4-M6 ZINC WASHER LOCK M6-1/4 NUT HEX 1/4-20 STEEL INSULATION RETAINMENT HANGER WASHER SELF LOCKING DOME #4-40 VISE-ACTION LATCH SLOTTED CIR TAB PULL INSULATION SPLITTER INSULATION ROOF TOP INSULATION DUCT TOP RIVET POP .1875 X .450 SS SPLITTER EXTENDED LENGTH INSULATION SPLITTER EXTENDED LENGTH INSULATION DOOR RETAINER INSULATION (820) INSULATION DUCT FRONT RETAINER INSULATION (740) SCREW HHC M6-1.0 X 20 G8.8 WASHER SHAKEPROOF INT 1/4 NUT HEX M6 X 1.0 G8 YEL CHR NUT HEX LOCK M6-1.0 SS NY INS ASSY WIRE 14 AWG 34.8" GRN/YEL KEY VISE-ACTION LATCH SLOT CIR WASHER SELF LOCKING DOME #8-32 STRIP SEALANT 1/8 X 1 (44.52”LG) (2) NOTE: PART NUMBER SHOWN IS FOR TAN / STEEL. REFER TO THE SAMPLE GUIDE BELOW FOR AVAILABLE COLOR AND/OR ALUMINUM PART NUMBER FORMAT. 0FXXXX0ST01 = TAN / STEEL 0FXXXX0ST13 = BISQUE / STEEL 0FXXXX0AL01 = TAN / ALUMINUM 0FXXXXALT13 = BISQUE / ALUMINUM 0FXXXX0ST08 = T- GRAY / STEEL 0FXXXX0ST14 = GRAY / STEEL 0FXXXX0AL08 = T- GRAY / ALUMINUM 0FXXXXALT14 = GRAY / ALUMINUM 0FXXXX0ST05 = WHITE / STEEL 0FXXXX0AL05 = WHITE / ALUMINUM (3) PART NUMBER SHOWN IS FOR TAN. SEE GUIDE BELOW FOR AVAILABLE COLOR AND PART NUMBER FORMAT. 0FXXXX0AL08 = T- GRAY / ALUMINUM 0FXXXXALT13 = BISQUE / ALUMINUM 0FXXXX0AL05 = WHITE / ALUMINUM 0FXXXXALT14 = GRAY / ALUMINUM 1 2 3 4 5 6 7 0F6207 0F4776 0F7357 025393 0F7278 070208 0G0896 0G0897 1 1 1 2 1 1 REF REF OUTLET 20A GFCI OUTLET 15A 250V NEMA 6-15R IVY BOX SQUARE 4-11/16 W/KNO'S SCREW HHTT #10-24 X 3/8 CZ COVER DUAL RECEPT 120/240 GROMMET .87 X .25 X .62 HARN ALT CON BOX 1PH QT HARN ALT CON BOX 3PH QT Stationary Emergency Generator Warranty GENERAC POWER SYSTEMS STANDARD LIMITED WARRANTY FOR COMMERCIAL STATIONARY EMERGENCY PRODUCT 50kW AND ABOVE For a period of two (2) years from the date of sale, Generac Power Systems, Inc. will, at its option, repair or replace any part(s) which, upon examination, inspection, and testing by Generac Power Systems or an Authorized/Certified Generac Power Systems Dealer, or branch thereof, is found to be defective under normal use and service, in accordance with the warranty schedule set forth below. Any equipment that the purchaser/owner claims to be defective must be examined by the nearest Authorized/ Certified Generac Power Systems Dealer, or branch thereof. This warranty applies only to Generac Power Systems Generators used in "Stationary Emergency" applications, as Generac Power Systems, Inc. has defined Stationary Emergency, provided said generator has been properly installed and inspected on-site by appropriate personnel. Scheduled maintenance, as outlined by the generator owner's manual, is highly recommended. This should be performed by an Authorized/Certified Generac Power Systems Dealer, or branch thereof. This will verify service has been performed on the unit throughout the warranty period. WARRANTY SCHEDULE YEAR ONE — Limited comprehensive coverage on mileage, labor, and parts listed. • - ALL COMPONENTS YEAR TWO — Limited comprehensive coverage on parts listed. • - ALL COMPONENTS *Start-up and/or On-line Registration, or Registration Card, along with Proof of Purchase, must be performed and/or sent in. Guidelines: • Any and all warranty repairs and/or concerns, must be performed and/or addressed by an Authorized/Certified Generac Power Systems Dealer, or branch thereof. • A Generac Power Systems, Inc. Transfer Switch is highly recommended to be used in conjunction with the genset. If a Non - Generac Power Systems, Inc. Transfer Switch is substituted for use and directly causes damage to the genset, no warranty coverage shall apply. • All warranty expense allowances are subject to the conditions defined in Generac Power Systems Warranty, Policies, and Procedures Flat Rate Manual. • Units that have been resold are not covered under the Generac Power Systems Warranty, as this Warranty is not transferable except with change of ownership of original structure. • Unit enclosure is only covered against rust or corrosion the first year of the warranty provision. • Use of Non-Generac replacement part(s) will void the warranty in its entirety. • Engine coolant heaters (block-heaters), heater controls and circulating pumps are only covered during the first year of the warranty provision (If applicable). THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Any unit built/manufactured prior to March 1, 2005. Costs of normal maintenance (i.e. tune-ups, associated part(s), adjustments, loose/leaking clamps, installation and start-up). Any failure caused by contaminated fuels, oils, coolants/antifreeze or lack of proper fuels, oils or coolants/antifreeze. Units sold, rated or used for "Prime Power", "Trailer Mounted" or "Rental Unit" applications as Generac Power Systems have defined Prime Power, Trailer Mounted or Rental Unit. Contact a Generac Power Systems Distributor for Prime Power, Trailer Mounted or Rental Unit definition. Units used for prime power in place of existing utility power where utility is present or in place of utility power where utility power service does not normally exist. Failures caused by any act of God and other force majeure events beyond the manufactures control. Products that are modified or altered in a manner not authorized by Generac Power Systems in writing. Failures due, but not limited to, normal wear and tear, accident, misuse, abuse, negligence, or improper installation or sizing. Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or replacement of the defective part(s). Failure due to misapplication, misrepresentation, or bi-fuel conversion. Telephone, facsimile, cell phone, satellite, internet, or any other communication expenses. Rental equipment used while warranty repairs are being performed (i.e. rental generators, cranes, etc.). Overtime, holiday, or emergency labor. Planes, ferries, railroad, busses, helicopters, snowmobiles, snow-cats, off-road vehicle or any other mode of transportation deemed abnormal. Any and all expenses incurred investigating performance complaints unless defective Generac materials and/or workmanship were the direct cause of the problem. Starting batteries, fuses, light bulbs, engine fluids, and overnight freight cost for replacement part(s). THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, SPECIFICALLY, GENERAC POWER SYSTEMS MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Any implied warranties which are allowed by law, shall be limited in duration to the terms of the express warranty provided herein. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to purchaser/owner. GENERAC POWER SYSTEMS ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC POWER SYSTEMS BE LIABLE FOR ANY INCIDENTAL, OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC POWER SYSTEMS, INC. NEGLIGENCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to purchaser/ owner. Purchaser/owner agrees to make no claims against Generac Power Systems, Inc. based on negligence. This warranty gives purchaser/owner specific legal rights. Purchaser/owner also may have other rights that vary from state to state Generac Power Systems, Inc. • P.O. Box 8 • Waukesha, WI 53187 Ph: (262) 544-4811 • Fax: (262) 544-4851 1-888-GENERAC (1-888-436-3722) Bulletin 0171370SVE / Rev. C 12.08 / Printed in U.S.A. Printed in U.S.A. EXPLODEDVIEW: EV BATTERY 6.8L CPL GROUP C DRAWING#: 0F3677 APPLICABLETO: ITEM PART# QTY. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0F3408 0F3411 G058208 G022131 050331A G050331 038805T 038804Y G045771 G022129 G027482 G075763 0C2454 0F3409 0J3501 1 1 1 1 1 1 1 1 1 1 1 1 8 1 1 REVISION: CN-0021496 DATE: 11/9/18 DESCRIPTION TRAY BATTERY STRAP BATTERY RETAINMENT BATT 12VDC 24F 625 WASHER FLAT 3/8-M10 ZINC BATT POST COVER RED + BATT POST COVER BLK CABLE BATT BLK #1 X 40.00 CABLE BATT RED #1 X 35.00 NUT HEX M8-1.25 G8 YEL CHR WASHER LOCK M8-5/16 WASHER SHAKEPROOF EXT 5/16 STL BOOT BATTERY CABLE SCREW THF M6-1X16 N WA Z/JS SUPPORT BATTERY TRAY STRAP BATTERY 1.5X36 Page 2 of 2 (2) 1 (2) 2 (2) 3 (3) 4 (2) 5 (2) 6 (3) 7 0F58660ST01 0F58610ST01 0F58650ST01 0F58640AL01 0F58620ST01 0F58630ST01 0F58600AL01 1 4 2 2 2 1 1 REAR WRAP C3 DOOR C3 CENTER SUPPORT C3 DISCHARGE DUCT LH & RH SIDE C3 FRONT CORNERS C3 DISCHARGE CENTER DUCT C3 ROOF C3 ALUM 8 9 10 11 12 14 15 16 17 18 19 20 21 22 25 26 27 29 30 31 32 33 34 35 36 37 38 40 41 (1) 42 43 44 45 46 0C2454 0E3257 0E5968 0F3949L 0F2766 0F3185 0F3416 0F3949E 0C2634A 022473 022097 022127 0F3072 078115 0F5048D 0F5049 0F3949B 0F4073A 0F4073F 087233 0F3180 0F3635C 0F4073 0F3890B 0F4073B 0F3890A 042568 022447 049813 077992 0912970094 0F8869D 078115A 066760 40 6 1 3 3 2 2 1 1 5 1 1 12 30 4 4 3 1 1 2 1 1 4 11 1 5 4 4 4 29 4 1 10 1 SCREW THF M6-1 X 16 N WA Z/JS SCREW TH-FRM M6 W/CAP SHKPRF W GASKET EXTRUDED TRIM (547” LG) INSULATION SPLITTER SML SPLITTER STRINGER SPLITTER C3 SUPPORT SPLITTER C5 130KW INSULATION ROOF TOP REAR ASSEMBLY COVER ACCESS WASHER FLAT 1/4-M6 ZINC WASHER LOCK M6-1/4 NUT HEX 1/4-20 STEEL INSULATION RETAINMENT HANGER WASHER SELF LOCKING DOME #4-40 VISE-ACTION LATCH SLOTTED CIR TAB PULL INSULATION SPLITTER INSULATION ROOF TOP INSULATION DUCT TOP RIVET POP .1875 X .450 SS SPLITTER EXTENDED LENGTH INSULATION SPLITTER EXTENDED LENGTH INSULATION DOOR RETAINER INSULATION (820) INSULATION DUCT FRONT RETAINER INSULATION (740) SCREW HHC M6-1.0 X 20 G8.8 WASHER SHAKEPROOF INT 1/4 NUT HEX M6 X 1.0 G8 YEL CHR NUT HEX LOCK M6-1.0 SS NY INS ASSY WIRE 14 AWG 34.8" GRN/YEL KEY VISE-ACTION LATCH SLOT CIR WASHER SELF LOCKING DOME #8-32 STRIP SEALANT 1/8 X 1 (44.52”LG) (2) NOTE: PART NUMBER SHOWN IS FOR TAN / STEEL. REFER TO THE SAMPLE GUIDE BELOW FOR AVAILABLE COLOR AND/OR ALUMINUM PART NUMBER FORMAT. 0FXXXX0ST01 = TAN / STEEL 0FXXXX0ST13 = BISQUE / STEEL 0FXXXX0AL01 = TAN / ALUMINUM 0FXXXXALT13 = BISQUE / ALUMINUM 0FXXXX0ST08 = T- GRAY / STEEL 0FXXXX0ST14 = GRAY / STEEL 0FXXXX0AL08 = T- GRAY / ALUMINUM 0FXXXXALT14 = GRAY / ALUMINUM 0FXXXX0ST05 = WHITE / STEEL 0FXXXX0AL05 = WHITE / ALUMINUM (3) PART NUMBER SHOWN IS FOR TAN. SEE GUIDE BELOW FOR AVAILABLE COLOR AND PART NUMBER FORMAT. 0FXXXX0AL08 = T- GRAY / ALUMINUM 0FXXXXALT13 = BISQUE / ALUMINUM 0FXXXX0AL05 = WHITE / ALUMINUM 0FXXXXALT14 = GRAY / ALUMINUM COMPONENTS INCL UDED IN 0G4140E 1 ENCL H/G CO NTROL PANEL 1 CO VER CONTRO L PANEL 1 HING E CONT INUOUS H PANEL 7 RIVET POP .125 X .275 SS 1 ASSY PROGRAMMED H- 100 1 DECAL FUSES LO CAT ED INSIDE 1 RAIL SNAPTRACK PCB HO LDER BULK ( 12” LG) 1 ASSY PCB 10A UL BATT CHRG R 12V 1 PLATE HARNESS CLAMP 1 ASSY PCB PW R AVR W /AMP HEADER 1 ASSY PCB BOSCH G OV DRIVER 1 DIO BR IDG E 25A 600V 11 W ASHER LO CK M5 4 SCREW PPHM M5- 0.8 X 30 SS 11 W ASHER FLAT M5 6 SCREW HHPM M5-0.8 X 12 5 NUT HEX M5-0.8 G8 YEL CHR 3 W ASHER FLAT M4 3 SCREW PHTT M4- 0.7 X 10 Z YC 1 CO NN DUST CAP W/CHAIN DB9 1 W ASHER FLAT M3.5 1 SCREW PHTT M3.5- 0.6 X 10 10 SCREW PPHM M4- 0.7 X 8 BLX O X 10 W ASHER LO CK #8-M4 1 DECAL W RN B AT T CHRG 12/24V BI 1 M5-0.8 CAPT IVE PANEL KNLD HD 2 SEAL COVER 3.18 X 12.7 X 382 1 SEAL COVER 3.18 X 12.7 X 283 1 HARNESS H-PNL INTEGRATED SW (NO T SHO WN) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 0F1823CST 03 0F1824AST 03 0F2606 036261 0F5763 0F1732 0E9764 0F1740C 0F1958 0F2256 0E3161 029673 049226 079224 051713 0F5886 051716 043180 0C3990 0F4333 0F5883 0F5884 055014 022264 0G 3546 0G 3648 0F6305 0F6305A 0G 4329 A B C D E 0F1263 0F1262 0F1264 0E9049B 055911 COMPONENTS INCL UDED IN WIRE HARNESS 1 ADPTR RH SIDE W ICKMANN 178.6191 4 HO LDER F USE WICKMANN 178.6150 1 ADPTR LH SIDE W ICKMANN 178.6192 1 ASSY PCB G-PANEL RELAY 12VDC 1 BL OCK TERM 20A 12 X 6 X 1100V 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 056739 0F2627B 022287 022473 022097 043182 051714 052777 0C2323 0F5459 0F5461 022127 0F5460 0E7403C 0E7403B 0F6145 0C2699 0C2266 COMPONENTS NO T INCLUDED IN 0G 4140E O R WIRE HARNESS 1 RELAY CONTACTO R 12VDC 1 DPE B REAKER SEE DRAW ING 0F9280 1 BO OST RESIST OR SEE DRAWING 0F 9280 1 CO VER CONTRO L PANEL SIDE 2 SCREW HHC 1/4-20 X 3/4 G 5 4 W ASHER FLAT M6-1/4 2 W ASHER LO CK M6-1/4 3 W ASHER LO CK M3 3 NUT HEX M3-0.5 G8 YEL CHR 3 W ASHER FLAT M3 2 SCREW PHTT #6-32 X 5/8 Z YC 1 DECAL CPL CONTRO L PANEL FUSES 1 DECAL CPL 5.4/6.8L TB3 2 NUT HEX 1/4-20 STEEL 1 DECAL CPL 5.4/6.8L RELAY BO ARD 1 F USE ATO TYPE 15 AMP (BL UE) 2 F USE ATO TYPE 10 AMP (RED) A/R SEAL WEATHER .45"DIA 2 SCREW PHTT #6-32 X 3/8 Z YC 4 SCREW PHTT M5- 0.8 X 16 Z YC (1) 1 (1) 2 3 4 (2) 5 (1) 6 7 8 9 10 11 (1) 12 0F3883 0F1960 0F2842 0F2843 0D5419 0F2849 0D3488G 0D3488L 0D3488K 057795A 059057 0F2844 0F2847 0F2839 1 1 8 1 1 1 1 1 1 1 1 1 1 1 TUBE HEATER WATER ENGINE 5.4L FORD IGNITION COIL ASSY FORD GASKET THERMOSTAT HOUSING FORD OIL FILTER FORD V-10 ENGINE TUBE OIL LEVEL INDICATOR FORD BELT SERPENTINE 65.0" (1800 RPM) SERPENTINE BELT (66.0") (2650 RPM) SERPENTINE BELT (68.3") (3600 RPM) BARBED EL 90 3/4 PLASTIC HOSE 3/4 ID SAE-30R2 (16.75”LG) THERMOSTAT ASSY FORD PULLEY FAN BELT FORD GASKET INTAKE MANIFOLD RIGHT (1) 13 (1) 14 15 16 (1) 17 18 19 20 21 22 23 24 25 26 27 28 29 30 (4) 31 32 33 (1) 34 (1) 35 (1) 36 (1) 37 (1) 38 (1) 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 (4)(3) 55 56 57 58 59 (1) 60 0F2840 0F1959 035579 0F2851 0F2848A 055440 022097 022473 042568 022129 0F4612 0E9868A 022145 057796 0F3216 0F3216B 0F3216D 0F3217 0F3287 0F3017 0F5991 0H3072 1 1 1 1 1 8 3 3 3 6 1 1 7 1 1 1 1 1 1 1 1 1 051713 042914 051731 022129 022145 051756 046526 022131 039253 064416 022131 046526 0D8027 0D8025 0D8026 0D8030 0F2846 0D8029 0D8028 0F2776A 045772 045771 0E0992A 057823 029333A 0F6151 0E0502 0F4308 036277 0H0550 8 2 9 9 9 2 2 2 3 1 2 1 4 2 3 1 1 1 1 2 1 2 8 3 2 2 1 1 1 1 GASKET INTAKE MANIFOLD LEFT INTAKE MANIFOLD 5.4L (PLASTIC) BSHG RDCR HEX 1/4 TO 1/8 CONNECTION WATER OUTLET FORD REWORK DIPSTICK 5.4L 27.75" SCREW HHC M5-0.8 X 25 G8.8 WASHER LOCK M6-1/4 WASHER FLAT 1/4 ZINC SCREW HHC M6-1.0 X 20 G8.8 WASHER LOCK M8-5/16 SENDER OIL PRESSURE 1/8"NPT ALTERNATOR DC W/OUT PULLEY WASHER FLAT 5/16 ZINC GROMMET PULLEY 80 OD DC ALTERNATOR (1800RPM) PULLEY 117 OD DC ALTERNATOR (2650 RPM) PULLEY 160 OD DC ALTERNATOR (3600 RPM) SPACER DC ALTERNATOR PULLEY BRKT DC ALTERNATOR UPPER BRKT DC ALTERNATOR LOWER HARN ENG 5.4L H-100 (USE WITH PROBE P/N 0E2507) HARN ENG G5.4L G3 H-100 CPL (USE WITH PROBE P/N 0H1827) WASHER FLAT M5 SCREW HHC M8-1.25 X 90 G8.8 SCREW HHC M8-1.25 X 50 G8.8 WASHER LOCK M8-5/16 WASHER FLAT 5/16-M8 ZINC SCREW HHC M10-1.5 X 20 G8.8 WASHER LOCK M10 WASHER FLAT 3/8-M10 ZINC SCREW HHC M8-1.25 X 20 G8.8 SCREW HHC M10-1.5 X 45 G8.8 FT WASHER FLAT 3/8-M10 ZINC WASHER LOCK M10 SCREW WP PULLEY M8-1.25 X 19 BOLT HEX FL HD M8-1.25 X 28 BOLT HEX FL HD M8-1.25 X 31 TENSIONER ENG. AUTOMATIC BELT PULLEY WATER PUMP FORD (1800RPM) PULLEY ENGINE WATER PUMP (2650 & 3600RPM) PULLEY GROOVED ENGINE IDLER BRACKET SIGNAL CONDITIONER NUT HEX M10-1.5 G8 YEL CHR NUT HEX M8-1.25 G8 YEL CHR PLUG EXPANSION 14 OD CLAMP HOSE #10 .56-1.06 TIE WRAP UL 7.4" X .19" BLK CAP RUBBER TEMPERATURE SENDER, DELPHI BRACKET DC ALT STABILIZER ELBOW 90D STREET 1/8 DECAL EPA STATIONARY EMERGENCY (1) NOTE: PART OF ENGINE MAKE P/N 0F3902. (2) NOTE: I/N 5 IS PART OF I/N 2. (3) NOTE: I/N 55 IS FOR HOLDING SENSOR TO I/N 50. (4) NOTE: NOT SHOWN 1 2 3 4 5 6 7 0F6207 0F4776 0F7357 025393 0F7278 070208 0G0896 0G0897 1 1 1 2 1 1 REF REF OUTLET 20A GFCI OUTLET 15A 250V NEMA 6-15R IVY BOX SQUARE 4-11/16 W/KNO'S SCREW HHTT #10-24 X 3/8 CZ COVER DUAL RECEPT 120/240 GROMMET .87 X .25 X .62 HARN ALT CON BOX 1PH QT HARN ALT CON BOX 3PH QT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 18 19 20 21 (3) 22 23 24 25 26 27 28 29 30 31(1) 32 33 34 35 36 37 38 39 40 (2)41 0F3144 035685 0F2857A 0F4168 0F4169 0E7854 0F2820 051756 046526 022131 052250 0F4412 0F4412A 039253 022129 022097 0C8566 0F4765 089685 0F2776A 0C2454 055596 0C7649 069860E 045764 065852 080712 076749 048031C 069811 0F4770 089514 0E2507 0H1827 0F4767 090283 022145 022132 077043J 085662 0F5589 1 4 1 1 1 1 1 4 4 4 2 1 1 8 8 8 8 1 1 1 15 / 1 1 1 1 1 1 1 1 1 REF 1 1 1 1 1 1 8 1 1 5 2 WELDMENT RAD SUPPORT C3 (22") CLAMP HOSE #28 1.32-2.25 RADIATOR 581 X 585 X 70 CPL LH HOSE UPPER RADIATOR C3 HOSE LOWER RADIATOR C3 CLUTCH COOLING FAN FAN 22" DIA 10 BLADE SCREW HHC M10-1.5 X 20 G8.8 WASHER LOCK M10 WASHER FLAT 3/8-M10 ZINC TAPE FOAM 1 X 1 (23” LG) SPACER FAN 6.8L SPACER FAN 5.4L SCREW HHC M8-1.25 X 20 G8.8 WASHER LOCK M8-5/16 WASHER LOCK M6-1/4 SCREW HHFC M6-1.0 X 20 G8.8 FTG CMPN BLKHD 3/8" OD TUBE BRS GROMMET .75 X .12 X .50 BRACKET SIGNAL CONDITIONER SCREW THF M6-1 X 16 N WA Z/JS BARBED STR 3/8 NPT X 3/8 CLAMP HOSE .38-.87 HOSE DRAIN ASSY 28" SCREW HHTT M4-0.7 X 8 BP SPRING CLIP HOLDER .37-.62 BRKT COOLANT RECOVERY TANK TANK COOLANT RECOVERY CLAMP HOSE BAND 1/4 CAP HEX 1/4 NPT BRASS TUBE FAN CLUTCH PREHTR LOWR C3 FTG CMPR 3/8TUBE X 3/8 NPT W/FERL PROBE COOLANT LEVEL 3/8 NPTF (USE WITH HARN P/N 0F5990 & 0F5991) PROBE COOLANT LEVEL 3/8-18NPTF (USE WITH HARN P/N 0H2595 & 0H3072) TUBE FAN CLUTCH PREHTR UPPR C2 CAP RADIATOR 13 PSI WASHER FLAT 5/16-M8 ZINC WASHER FLAT 9/16 ZINC CONDUIT FLEX 2.0"ID TIE WRAP UL 14.6 X .14 BLK GUARD FAN C3 CPL (1) ITEM 31 IS INCLUDED WITH ITEM 25. (2) ENCLOSED SETS ONLY (3) QTY. REQUIRED FOR ENCLOSED UNITS / QTY. REQUIRED FOR OPEN UNITS. 1 2 3 4 5 6 7 8 9 10 0G16140GS0R 0G16150GS0R 0G15300GS0R 0G16130GS0R 0D3215B 0C2454 022097 049813 0C2634A 047411 2 2 1 1 2 32 1 1 1 1 PANEL C3 FRONT SIDES PANEL C3 REAR SIDES PANEL LOWER FRONT PANEL C3 TOP ACCESS COVER 160 X 170 GALV SCREW THF M6-1 X 16 N WA Z/JS WASHER LOCK M6-1/4 NUT HEX M6 X 1.0 G8 YEL CHR ASSY ACCESS COVER SCREW HHC M6-1.0 X 16 G8.8 OPEN SETS ONLY 1 2 3 4 5 6 7 8 0G17420GS0R 0G17390GS0R 0G17400GS0R 0G17410GS0R 056326 0C2454 056326 056326 1 1 1 1 1 22 1 1 GUARD BELT RIGHT HAND C3 GUARD BELT TOP C3 GUARD BELT BOTTOM C3 GUARD BELT LEFT HAND C3 TRIM VINYL BLACK 1/8GP (21” LG) SCREW THF M6-1 X 16 N WA Z/JS TRIM VINYL BLACK 1/8GP (10 .37” LG) TRIM VINYL BLACK 1/8GP (12” LG) Stationary Emergency Generator Warranty GENERAC POWER SYSTEMS STANDARD LIMITED WARRANTY FOR COMMERCIAL STATIONARY EMERGENCY PRODUCT 50kW AND ABOVE For a period of two (2) years from the date of sale, Generac Power Systems, Inc. will, at its option, repair or replace any part(s) which, upon examination, inspection, and testing by Generac Power Systems or an Authorized/Certified Generac Power Systems Dealer, or branch thereof, is found to be defective under normal use and service, in accordance with the warranty schedule set forth below. Any equipment that the purchaser/owner claims to be defective must be examined by the nearest Authorized/ Certified Generac Power Systems Dealer, or branch thereof. This warranty applies only to Generac Power Systems Generators used in "Stationary Emergency" applications, as Generac Power Systems, Inc. has defined Stationary Emergency, provided said generator has been properly installed and inspected on-site by appropriate personnel. Scheduled maintenance, as outlined by the generator owner's manual, is highly recommended. This should be performed by an Authorized/Certified Generac Power Systems Dealer, or branch thereof. This will verify service has been performed on the unit throughout the warranty period. WARRANTY SCHEDULE YEAR ONE — Limited comprehensive coverage on mileage, labor, and parts listed. • - ALL COMPONENTS YEAR TWO — Limited comprehensive coverage on parts listed. • - ALL COMPONENTS *Start-up and/or On-line Registration, or Registration Card, along with Proof of Purchase, must be performed and/or sent in. Guidelines: • Any and all warranty repairs and/or concerns, must be performed and/or addressed by an Authorized/Certified Generac Power Systems Dealer, or branch thereof. • A Generac Power Systems, Inc. Transfer Switch is highly recommended to be used in conjunction with the genset. If a Non - Generac Power Systems, Inc. Transfer Switch is substituted for use and directly causes damage to the genset, no warranty coverage shall apply. • All warranty expense allowances are subject to the conditions defined in Generac Power Systems Warranty, Policies, and Procedures Flat Rate Manual. • Units that have been resold are not covered under the Generac Power Systems Warranty, as this Warranty is not transferable except with change of ownership of original structure. • Unit enclosure is only covered against rust or corrosion the first year of the warranty provision. • Use of Non-Generac replacement part(s) will void the warranty in its entirety. • Engine coolant heaters (block-heaters), heater controls and circulating pumps are only covered during the first year of the warranty provision (If applicable). THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Any unit built/manufactured prior to March 1, 2005. Costs of normal maintenance (i.e. tune-ups, associated part(s), adjustments, loose/leaking clamps, installation and start-up). Any failure caused by contaminated fuels, oils, coolants/antifreeze or lack of proper fuels, oils or coolants/antifreeze. Units sold, rated or used for "Prime Power", "Trailer Mounted" or "Rental Unit" applications as Generac Power Systems have defined Prime Power, Trailer Mounted or Rental Unit. Contact a Generac Power Systems Distributor for Prime Power, Trailer Mounted or Rental Unit definition. Units used for prime power in place of existing utility power where utility is present or in place of utility power where utility power service does not normally exist. Failures caused by any act of God and other force majeure events beyond the manufactures control. Products that are modified or altered in a manner not authorized by Generac Power Systems in writing. Failures due, but not limited to, normal wear and tear, accident, misuse, abuse, negligence, or improper installation or sizing. Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or replacement of the defective part(s). Failure due to misapplication, misrepresentation, or bi-fuel conversion. Telephone, facsimile, cell phone, satellite, internet, or any other communication expenses. Rental equipment used while warranty repairs are being performed (i.e. rental generators, cranes, etc.). Overtime, holiday, or emergency labor. Planes, ferries, railroad, busses, helicopters, snowmobiles, snow-cats, off-road vehicle or any other mode of transportation deemed abnormal. Any and all expenses incurred investigating performance complaints unless defective Generac materials and/or workmanship were the direct cause of the problem. Starting batteries, fuses, light bulbs, engine fluids, and overnight freight cost for replacement part(s). THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, SPECIFICALLY, GENERAC POWER SYSTEMS MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Any implied warranties which are allowed by law, shall be limited in duration to the terms of the express warranty provided herein. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to purchaser/owner. GENERAC POWER SYSTEMS ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC POWER SYSTEMS BE LIABLE FOR ANY INCIDENTAL, OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC POWER SYSTEMS, INC. NEGLIGENCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to purchaser/ owner. Purchaser/owner agrees to make no claims against Generac Power Systems, Inc. based on negligence. This warranty gives purchaser/owner specific legal rights. Purchaser/owner also may have other rights that vary from state to state Generac Power Systems, Inc. • P.O. Box 8 • Waukesha, WI 53187 Ph: (262) 544-4811 • Fax: (262) 544-4851 1-888-GENERAC (1-888-436-3722) Bulletin 0171370SVE / Rev. C 12.08 / Printed in U.S.A. Printed in U.S.A.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project