Hunter Claudette Installation manual


Add to my manuals
12 Pages

advertisement

Hunter Claudette Installation manual | Manualzz

Pull Chain w/LIGHT or Remote not button w/ NO LIGHT or Remote no button w/ LIGHT

Model: 59621 Polished Nickel 59622 Modern Brass Fan weight ±2 lbs: 23.5 lbs (10.7 kg)

Claudette

Installation Manual

©2019 Hunter Fan Co.

PG3780 r061319

Congratulations on purchasing your new Hunter

®

ceiling fan!

The ceiling fan you purchased will provide comfort and performance in your home or office for many years. This instruction manual contains complete instructions for installing and operating your fan. We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world.

We are here to help!

This Instruction Manual is designed to make installation as simple as possible. While working through this Instruction Manual, keep your smartphone or tablet nearby. We have added video links to help you through the more technical sections. If you are unfamiliar or uncomfortable with wiring, contact a qualified electrician. We also provide telephone support at 1.888.830.1326 or visit us at HunterFan.com.

READ and SAVE These Instructions

WARNING

1886

Warning

w.1 - To reduce the risk of fire, electrical shock, or personal injury, mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the mounting screws provided with the outlet box.

w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.

w.3 – To reduce the risk of electric shock, this fan must be installed with an isolating wall control/switch.

w.4 - To reduce the risk of personal injury, do not bend the blade brackets when installing the blade brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

Caution

c.1 - All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician. c.2 - Use only Hunter replacement parts.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.

Caution: modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This product conforms to UL Standard 507.

Here are the tools you’ll need to complete your installation:

OPTIONAL

If mounting to a support structure, you will also need these tools.

Ladder Screwdriver Drill 9/64” Drill Bit

1

Pliers Wire Strippers

1886

Here is what comes in your box:

We recommend that you pull everything out of the box and lay it out. We have grouped the drawn components below with the hardware you’ll need for those parts. The screws below are drawn to scale to make it easier to identify what piece of hardware is needed to install each component.

Hunter Pro Tip: Do not discard the hardware bags or mix parts from different bags. Make note of the symbol printed on each hardware bag. The symbols can be used to identify the appropriate hardware for each step.

1886

bag Washer x2 For installing the hanger bracket and wiring the fan Wood Screw x2 Wire Nut x4 Ceiling Bracket Canopy Canopy Screw x2 bag For installing the canopy Downrod bag x10 Blade Screw Motor Blade x5 bag x10 Blade Washers Light Kit Assembly For installing the blades Switch Housing Plate Pullchains and extra downrod Bulb x2 Glass bag Spare Parts For your convenience, you may receive extra fasteners.

M3752-01 r062019 bag x3 Light Kit Screw x6 Short Light Kit Screw For installing the light kit Find a part that is missing or damaged?

Don’t take it back to the store. Let us make it right. Visit us at HunterFan.com or call us at 1.888.830.1326.

2

1886

Choosing the Right Installation Location

You probably bought this fan with a location in mind. Let’s check below to make sure it is a good fit.

Check the room dimensions: Check the outlet box: 30 inches

from blade tip to nearest wall or obstruction

You must be able to secure the fan to building structure or fan-rated outlet box.

7 feet

from bottom edge of blade to the floor

Standard Mounting

Support Structure

Checking the Ceiling Angle: Angled Mounting

Support Structure Ceiling Outlet Box (required) Ceiling Outlet Box (required)

If you have a flat ceiling:

Hang your fan by a standard downrod. Some fans come with a shorter downrod for a Low Profile installation.

If you have an angled or vaulted ceiling:

1. You will need a longer downrod. (sold separately at HunterFan.com) 2. If your ceiling angle is greater than 34°, you will also need an Angled Mounting Kit. (Sold separately at HunterFan.com)

Angled Mounting A little more information on Angled Mounting:

For optimum performance and appearance, a longer downrod should be used with your Hunter ceiling fan when installing on high or angled ceiling. If your ceiling is angled greater than 34 sold separately at HunterFan.com

.

° you will also need an Angled Mounting Kit. Longer downrods and the Angled Mounting Kit are Hunter Pro Tip: Determining if you need an Angled Mounting Kit: Fold on the dotted line. Place against edge againts the wall. Slide towards the ceiling.

If the guide touches the wall but not the ceiling, you need an angled mounting kit.

3 34°

WALL

Installing the Ceiling Bracket

1886

Installing the Downrod

1886

Check the outlet box: Installing the Ceiling Bracket

You have

two options

for installation. Pick which one works best for your location. Remove any existing bracket prior to installation.

Only use the provided Hunter ceiling bracket that came in your fan’s box.

Do this first!

Hunter Pro Tip: The machine screws are the ones that came with your outlet box.

1886

ow er

WARNING

To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location.

Washer x2

Option 1:

Machine Screws

Use machine screws

(provided with outlet box)

and washers when securing to existing ceiling fan-rated outlet box. Make sure it is securely installed and is acceptable for fan support of 31.8 kg (70 lbs) or less.

A NGL ED

MOUNTING TIP

For angled ceilings, point opening toward peak.

Option 2:

Wood Screws

Use wood screws and washers (included) when securing to support structure with approved electrical outlet box. Drill 9/64” pilot holes in support structure to aid in securing ceiling bracket with hardware found in the hardware bag.

bag x2 Wood Screw 1

Installing the Downrod

Follow below if you are using the downrod that came pre-assembled in your box. Need to install a longer or shorter downrod? Check out the guide at the end of this manual.

Hunter Pro Tip: 2 The ground wire attached to the downrod is approximately 8 inches.

U T

3/8”

& ST

8” 3 Tighten the setscrew with pliers.

DO NOT HAND TIGHTEN. KEEP!

Remove the pre-installed setscrew so that the downrod can be inserted.

Pass all wires to one side of horizontal bar in downrod assembly. Hand tighten the downrod (at least 4–5 full turns) until it stops. Trim the wires coming from the fan so that 8-inches remain coming from the top of the downrod.

WARNING

FAN FALL HAZARD

To prevent SERIOUS INJURY or DEATH: • ALWAYS tighten setscrew with pliers.

• DO NOT hand tighten setscrew.

• CHECK the setscrew is tight using pliers each time you change fan direction.

Ceiling Bracket Downrod Hanging Fan Wiring Canopy Blades Light Bulbs/Glass Pull Chains 4

1886

an c op y o ve r d ow nrod

and w ires.

Progress Check:

Your fan should look like this.

Hanging the Fan

NOTICE

To prevent damage to fan, ALWAYS lift holding either the fan housing or the downrod.

Place the downrod ball into the slot in the ceiling bracket. 5 Ceiling Bracket Downrod Hanging Fan Wiring Canopy Blades Light Bulbs/Glass Pull Chains

Wiring the Fan

1886

1886

Wiring the Fan We know wiring is hard. Let’s make it easier.

Follow these steps to get your fan wired quickly and safely. Follow the route below that best matches your wall switch setup. If you are unfamiliar with wiring or uncomfortable doing it yourself, please contact a qualified electrician.

You are going to need these: 4 Wire Nuts (these are in the bag)

Hunter Pro Tip:

Here is how to connect the wires:

Push the bare metal ends of the wires together and slide a wire nut over them. Then, twist the wire nut clockwise until tight.

Give it a gentle pull to make sure none of the wires are loose.

Have a single switch?

Follow these steps:

Connect the white (grounded) wire from the ceiling to the white wire from the fan.

Connect the black wire (ungrounded) from the ceiling to the black and the blue wires from the fan. White Grounded Blue Black Grounding e r G en /Ye l low Str ipe Green/Yellow Stripe bag Wire Nut x4 Connect the three grounding wires (green, green/yellow stripe, or bare copper) coming from the ceiling, downrod, and hanging bracket.

1886 WARNING

The ceiling fan must be grounded. If the ground wire for the installation site is not present, immediately

STOP

installation and consult a qualified electrician.

WARNING

All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring or in doubt, consult a qualified electrician.

Hunter Pro Tip:

Have extra wiring?

Turn the wires upward and push them carefully back through the hanger bracket into the outlet box. Make sure that the wires are still attached to the wire nuts.

Have dual switches?

Follow these steps:

Connect the white (grounded) wire from the ceiling to the white wire from the fan.

Connect the black (ungrounded) wire from the ceiling to the black wire from the fan.

White Grounded Ungrounded Black Blue Ung rounded (light) Connect the second ungrounded (light) wire from the ceiling to the blue wire from the fan.

Grounding e r G en /Ye l low Str ipe Green/Yellow Stripe bag Wire Nut x4 Connect the three grounding wires (green, green/yellow stripe, or bare copper) coming from the ceiling, downrod, and hanging bracket.

Ceiling Bracket Downrod Hanging Fan Wiring Canopy Blades Light Bulbs/Glass Pull Chains 6

1886

Installing the Canopy

Insert the two canopy screws found in the hardware bag.

bag x2 Canopy Screw e c th an op y in pla ce as s hown.

Lift the canopy into place so that the screw holes are aligned. Hunter Pro Tip:

Let the tool do the work!

A magnetic screwdriver will give you more visibility when securing the canopy.

Installing the Blades:

Insert the blade into the blade slot around the center screw. Put the blade washers found in the hardware bag onto the blade screws found in the hardware bag. Then install the blade screws to secure each blade to the fan.

Repeat x5

bag Blade Screw x10 bag Blade Washer x10 7 Ceiling Bracket Downrod Hanging Fan Wiring Canopy Blades Light Bulbs/Glass Pull Chains

1886

1886

Installing the Canopy Installing the Blades: Assembling the LIght Kit

bag 2 of 3 Light Kit Screw Partially install two light kit assembly screws, found in the hardware bag, halfway into the motor housing as shown. It does not matter which two screw holes you choose.

bag 1 of 3 Light Kit Screw Feed the 9-pin plug connector coming from the bottom of the motor housing through the center hole in the light kit assembly. Connect it to the plug connector found in the switch housing area of the light kit assembly. Make sure to line up the colored markings on the connectors.

Align the keyhole slots in the top of the light kit assembly with the partially installed assembly screws. Wrap the keyhole slots around the screws and twist counterclockwise.

bag 2 of 2 Short Light Kit Screw

1886

Insert the third screw, found in the hardware bag, in place and firmly tighten all the three screws.

Carefully push all switch housing components into the switch housing, then install the switch housing plate using two short light kit assembly screws, found in the hardware bag.

WARNING FAN FALL HAZARD

Make sure all screws are tight to secure the light fixture.

Installing the Bulbs and Glass

Tab Install the included LED bulbs into the sockets. When necessary, replace with bulbs of same wattage.

Notch Lift the globe and align the notches in the globe with the tabs in the light kit.

Ceiling Bracket Downrod Hanging Fan Wiring Canopy Turn P ow er

ON

Attach the globe by lifting and turning clockwise one third of a full turn of the glass until it stops.

NOTE: Check to ensure proper engagement.

Blades Light

WARNING GLASS FALL HAZARD

To prevent SERIOUS INJURY or DEATH , make sure that glass is properly secured.

Bulbs/Glass Pull Chains 8

1886

Installing the Pull Chains

Remove and discard the plastic connectors from the ends of the short pull chain. Feed the pull chains from the fan switch and the light switch down through the holes in the upper switch housing as shown. Attach the pull chain pendants to the light and fan pull chains.

The fan pull chain controls the speed: from high to off.

The light pull chain controls the light fixture: on and off.

Reversing the Fan

Reverse Switch Ceiling fans work in two directions: downdraft and updraft. To change the direction of air flow, turn the fan off and let it come to a complete stop. The reversing switch is located inside the light fixture. It can only be accessed when the glass is removed. Slide the reversing switch to the opposite position. Restart the fan.

Updraft (clockwise rotation) creates a more indirect airflow. Updraft airflow is great for moving warm air downward.

Downdraft (counterclockwise rotation) creates a direct breeze and maximum cooling effect.

9 Ceiling Bracket Downrod Hanging Fan Wiring Canopy Blades Light Bulbs/Glass Pull Chains

Troubleshooting

1886

1886

Installing the Pull Chains Troubleshooting

Fan Doesn’t Work • Make sure power switch is on.

• Check the circuit breaker to ensure the power is turned on.

• Make sure the blades spin freely.

• Turn off power from the circuit breaker, then loosen the canopy and check all the connections according to the wiring diagram.

Excessive Wobbling • Make sure the blades are properly installed on the blade iron posts.

• Turn the power off, support the fan carefully, and check that the hanger ball is properly seated.

• Use the provided balancing kit and instructions to balance the fan.

Noisy Operation • Make sure the blades are properly installed.

• Check to see if any of the blades are cracked. If so, replace all of the blades.

Hunter Pro Tip:

Cleaning the Fan

Use soft brushes or cloths to prevent scratching. Cleaning products may damage the finishes.

Limited Lifetime Warranty

Hunter Fan Company grants this limited warranty to the original purchaser of this Hunter ceiling fan. This document can be found at www.HunterFan.com. Thank you for choosing Hunter!

How Can Warranty Service Be Obtained?

Proof of purchase is required

when requesting warranty service. The original purchaser must present a sales receipt or other document that establishes proof of purchase. Hunter, at its sole discretion, may accept a gift receipt. To obtain service, contact Hunter Fan Company online or by phone.

www.HunterFan.com/Support/Contact-Us/ 1-888-830-1326 Please do not ship your fan or any fan parts to Hunter. Delivery will be refused.

What Does This Warranty Cover?

Motor — Limited Lifetime Warranty

If any part of your ceiling fan motor fails during your ownership of the fan due to a defect in material or workmanship, as determined solely by Hunter, Hunter will provide you with a replacement fan free of charge.* The foregoing limited warranty applies only to the motor itself and does not apply to electronic controls – such as remote control transmitters, remote control receivers, or capacitors – used in conjunction with the motor. Such electronic control items are included in the one-year limited warranty below.

Other — One-Year Limited Warranty

Except as otherwise indicated throughout this warranty, if any part of your Hunter ceiling fan fails at any time within one year of the date of purchase due to a defect in material or workmanship, as determined solely by Hunter, Hunter will provide a replacement part free of charge.*

Light Kits — Warranty May Vary

Light kits are included in the one-year limited warranty. However, you may qualify for additional warranty coverage if your fan includes one of the following: •

LED Light Kits — Three-Year Limited Warranty

If your LED light kit module (not including glass components) or LED bulb fails at any time within three years of the date of purchase due to a defect in material or workmanship, as determined solely by Hunter, Hunter will provide a replacement part free of charge.*

* If no replacement product/part can be provided for your fan, we will provide a comparable or superior replacement product/part at the sole discretion of Hunter.

What Does This Warranty NOT Cover?

Labor Excluded. This warranty does not cover any costs or fees associated with the labor (including electrician’s fees) required to install, remove, or replace a fan or any fan parts. There is no warranty for light bulbs (except where otherwise noted); remote control batteries; fans purchased or installed outside the United States; fans owned by someone other than the original purchaser; fans for which proof of purchase has not been established; fans purchased from an unauthorized dealer; ordinary wear and tear; minor cosmetic blemishes; refurbished fans; and fans that are damaged due to any of the following: improper installation, misuse, abuse, improper care, failure to follow Hunter instructions, accidental damage caused by the fan owner or related parties, modifications to the fan, improper or incorrectly performed maintenance or repair, improper voltage supply or power surge, use of improper parts or accessories, failure to provide maintenance to the fan, or acts of God (e.g. flood). ORIGINAL PURCHASER’S SOLE AND EXCLUSIVE REMEDY FOR A CLAIM OF ANY KIND WITH RESPECT TO THIS PRODUCT SHALL BE THE REMEDIES SET FORTH HEREIN. HUNTER FAN COMPANY IS NOT RESPONSIBLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, DUE TO PRODUCT FAILURE, WHETHER ARISING OUT OF BREACH OF WARRANTY, BREACH OF CONTRACT, OR OTHERWISE. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE APPLICABLE TO THIS PRODUCT ARE LIMITED IN DURATION TO THE PERIOD OF COVERAGE OF THE APPLICABLE LIMITED WARRANTIES SET FORTH ABOVE. Some States do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

How Does State Law Affect Warranty Coverage?

This warranty gives you specific legal rights. You may also have other rights which vary from state to state.

10

1886

1886

Downrod If you need a different downrod length follow these steps: Follow steps 1-5 to remove standard downrod pipe

1 2 3 4 5

1886

10 9 8

Follow steps 6-10 to reassemble with new downrod

7 6

WARNING

FAN FALL HAZARD

To prevent SERIOUS INJURY or DEATH: • ALWAYS tighten setscrew with pliers.

• DO NOT hand tighten setscrew.

• CHECK the setscrew is tight using pliers each time you change fan direction.

11

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement