Legrand BMS Interface Module for SWS (HBMS8SS) Installation Instruction
PDF
নথি
বিজ্ঞাপন
বিজ্ঞাপন
The Building Management System Interface Module (HBMS8SS) provides an intelligent interface to other building systems, such as HVAC or Security. The HBMS8SS is used instead of a Network Clock (HCLK8SS) to provide smart control scenarios for up to eight global lighting groups (channels) in the Smartwired Switching network. Instead of scheduling channels itself (like the HCLK8SS), the BMS Interface accepts input from an external system to signal whether that group is Occupied or Unoccupied. For example, in some retail applications, it may be more convenient to turn on lighting when the security system is disabled just as staff arrives. From a simple contact closure, the BMS Interface automatically applies the proven control scenarios selected during setup. Features • Eight automation channels • Up to four user-selectable control scenarios • 2-line, 16-character display • Menu-driven data entry • Easily configured contact closure inputs and status feedback • Blink warnings and individual timed overrides • Optional egress delay • Automatically interfaces with Photocell Control Module (HPCU8SS) Before proceeding, read the instructions on the following pages. For an overview of the entire system and the documentation forms, refer to the other sections of the SMARTWIRED SWITCHING SYSTEM INSTALLATION AND OPERATION MANUAL. If you have any questions, call our Service Team at: 888-852-2778. The Smartwired™ Switching (SS) System is a small network of relay panels and occupant control switches linked by a 4-wire dataline. Together these devices form a reconfigurable switching platform that uses “smartwiring” instead of hardwiring to link occupant switches to relays. Santa Clara, CA 95050 © 2001 The Watt Stopper,® Inc. Installation Instructions HBMS8SS Smartwired™ BMS Interface Module Installation and Setup HBMS8SS Building Management System Interface Module — Installation and Setup Operation ™ In a Smartwired Switching System, relays and their associated lighting loads may be “smartwired” — or grouped for common control — to one of eight channels in the relay panel, or to the button of a dataline switch. When there is no automation module (either a Network Clock or BMS Interface Module) in the network, relays may be controlled manually by a wall switch, automatically by a sensor, or by an interface to some other system. When the BMS Interface Module (or Network Clock*) is added to the system, the eight channels A-H have the capability to become “global” — or system-wide — automation groups. Relays grouped to Channel A in Panel 01 and relays grouped to Channel A in Panel 02 can be controlled as a single global group. With the BMS Interface Module, the user may assign an automation “scenario” to any channel. The type of scenario chosen depends on how the building space is to be used. Questions the user should ask include: • Is it an interior or exterior space? • Should occupants turn lights on when they arrive, or should lights turn on automatically? • Do occupants need to be warned when lights are about to turn off? • Should exterior lighting stay on all night, or turn off after the building is closed? On the HBMS8SS, each channel has its own connection to an external source — whether that’s the building’s HVAC system, security system, or some other source of scheduling input — with both input contacts and status feedback contacts. The input contacts are user-definable, and through a simple contact closure provide “Occupied” or “Unoccupied” status to the BMS Interface module. With this information, the HBMS8SS will control the lighting based on the smart scenarios selected by the user. Since there are a total of eight global channels, careful thought must be given to which groups of relays share common scheduling and automation scenarios. Automation Scenarios Each channel may be assigned any one of four different automation scenarios as follows: 2 The following two scenarios for exterior lighting appear automatically as menu selections in the HBMS8SS when an HPCU8SS Photocell Control Module is connected to the system. Programming scenarios for the channels is still done through the HBMS8SS. The Photocell Control Module receives actual light level data from the HPSA Photocell Sensor mounted on the building’s roof and wired to the HPCU8SS. (For testing, a simulated light level function is available.) Interior Lighting For details on the Photocell Control Module, refer to the installation instructions INHPCU8. Scenario 1: Scheduled ON/OFF (Interior Lighting) Scenario 3: Dark ON/OFF (Exterior Lighting – Security) Relays smartwired to channels assigned this scenario will turn on whenever the channel’s input contact signals “Occupied”, and off when it signals “Unoccupied.” As an option, the lights will blink to alert occupants five minutes before the lights turn off. Any HDLS series dataline switch button controlling affected relays will also begin to flash. Pressing the switch button will stop the flashing and start a timed delay for that relay, overriding the off command. An egress delay up to 4 hours may also be set for the channel. Relays smartwired to channels assigned this scenario will turn on when it is dark outside and turn off when it is light. “Dark” is defined by the user in footcandles. Typical settings for Security lighting are from 2 to 20 fc. Data required by the BMS Interface Module: A Override time delay (in 10-minute increments, up to 4 hours) B Blink Warn? Yes/No C Egress Time (in 10-minute increments, up to 4 hours) D Define “Occupied” for Input Contact (Occupied = Open or Closed contact) E Define Status Contact (Closed contact = Any ON, All ON, All OFF, Any OFF) Scenario 2: Manual ON/Scheduled OFF (Interior Lighting – Alternate) * Only one Network Clock or BMS Interface Module can be used in a single Smartwired Switching network to provide smart control scenarios. If the HBMS8SS module is the primary controller, an HCLK8SS Clock module should not be connected to the dataline, but may be used in Programming mode to program dataline switches. Exterior Lighting Relays smartwired to channels assigned this scenario will not turn on until turned on by an occupant, even if the channel’s input contact signals “Occupied.” During Unoccupied periods, this scenario acts the same as Scenario 1 and requires the same data input. Data required by the BMS Interface Module: A Define “Dark” from 2 to 200 fc B Define Status Contact (Closed contact = Any ON, All ON, All OFF, Any OFF) Scenario 4: Dark ON/Scheduled OFF (Exterior Lighting – Parking Lots, Signs) Typical settings for Parking Lot lighting are from 2 to 20 fc, and for Signage, 20 to 200 fc. Egress Time is the delay between the Unoccupied signal and the time the lights should actually turn off. It is used to allow safe exit for the last building occupants. Data required by the BMS Interface Module: A Egress Time (in 10-minute increments up to 4 hours) B Define “Dark” from 2 to 200 fc C Define “Occupied” for Input Contact (Occupied = Open or Closed contact) D Define Status Contact (Closed contact = Any ON, All ON, All OFF, Any OFF) HBMS8SS Building Management System Interface Module — Installation and Setup Sample Smartwired Switching System Application To help illustrate how to program the BMS Interface Module, the following application, a two-story office building, shown below in Figure 1, is used. There is one Smartwired Switching panel per floor, and each panel contains 16 relays controlling open office space and 4 relays controlling hallways and common areas. There are also 4 relays for exterior security lighting, and 6 for parking lot lighting and signage in panel 01. The sample documentation forms on page 4 summarize the data entry required by the BMS Interface Module and indicate how relays are associated with channels. Channel A is assigned a Manual ON/Scheduled OFF scenario for open office areas. In these areas, lights will be turned on by occupants upon arrival, and off when the channel goes “unoccupied”. A two-hour timed override will be in effect during unoccupied times. Channel B is assigned a Scheduled ON/Scheduled OFF scenario for hallways and common areas. In these areas, lighting will be turned on and off based on the occupied/unoccupied input to the channel. A two-hour timed override will be in effect during unoccupied times. Channel C is assigned a Dark ON/OFF scenario for exterior security lighting. This lighting depends only on actual light levels outside, as measured by the Photocell Sensor and sent through the Photocell Control Module. Lighting will turn on when it is dark and off when it is light outside, regardless of building occupancy. Channel D is assigned a Dark ON/Scheduled OFF scenario for parking lot lighting and signage. Nonsecurity exterior lighting depends on actual light levels outside, as well as building occupancy. The lights will turn on when it is dark if the building is occupied, and will turn off when it is light, or when the building becomes unoccupied. A one-hour egress delay allows safe exit for building occupants. In some applications, such as a retail store, signage may be turned off when the store closes, well before parking lot lighting turns off. In this case, parking and signage should be assigned to separate channels (for example: D and E) to allow for different treatment. Figure 1 – Sample Smartwired™ Switching Application CHANNEL A RELAYS — OPEN OFFICE AREAS CHANNEL B RELAYS — HALLWAYS AND COMMONS CHANNEL C RELAYS — EXTERIOR SECURITY LIGHTING CHANNEL D RELAYS — PARKING LOT LIGHTING AND SIGNAGE SS PANEL 01 FIRST FLOOR SS PANEL 02 SECOND FLOOR 3 HBMS8SS Building Management System Interface Module — Installation and Setup Documenting Automation Scenarios And Relays Before proceeding with any smartwiring or programming, it is necessary to complete system documentation. First, complete the BMS Interface Module Automation Scenarios form, recording which scenario will be assigned to each channel (Figure 2). Then, record the relays in each panel to be associated with those channels on the Relay Schedule form (Figure 3). A relay should only be associated with one automation channel. Both forms are in the Documentation section of the Smartwired Switching System Installation and Operation Manual. Figure 2 씰 Figure 3 쑼 4 HBMS8SS Building Management System Interface Module — Installation and Setup Installation And Smartwiring When both the BMS Interface Module Automation Scenarios form and the Relay Schedule form are complete, begin the HBMS8SS installation as follows: Step 1: Install the BMS Interface Module The HBMS8SS snaps onto the DIN rail in any Smartwired relay panel. (There is a release clip on the bottom of the module.) Identify the panel where the inputs from other systems will be connected, and snap the BMS Interface Module onto its DIN rail. Step 2: Wire the Input and Status Contacts for Each Channel See Figure 4. Input Contacts: Red/White 2-wire maintained dry contact input Status Contacts: Yellow/Yellow Ratings: 1 Amp, 24 VAC Note: Default settings for the Scenario (Scheduled ON/OFF) and Input Contact (Closed = Occupied) may cause the system to respond when the input contact is connected. Step 3: Smartwire Each Relay to its Associated Channel If this has not already been done during installation of the relay panels, smartwire relays to their associated channels as shown in Figure 5,referring to the Relay Schedule form as shown in Figure 3. Step 4: Connect the BMS Interface Module and Enter Data Plug the attached cable into the LOCAL DATALINE connector in any relay panel, providing power to the BMS Interface Module. During the power-up sequence, the screen will display the firmware version number of the unit. Also, the LEDs on the face of the unit will turn first Red, then Green, then Off. Figure 4 – HBMS8SS Input and Status Contact Wiring Figure 5 – Smartwiring Relays to Channels 1 2-CONDUCTOR 20 AWG RED/WHITE 1000 FT. MAXIMUM R W Y Y MAINTAINED ISOLATED (DRY) CONTACT 2-CONDUCTOR YELLOW/YELLOW STATUS OUTPUT TO BAS (1A @ 24VAC MAXIMUM) A B FLASHING RED LED PRESS AND HOLD CHANNEL PUSH BUTTON 2 3 FLASHING LED PRESS RELAY CONTROL BUTTON PRESS CHANNEL PUSH BUTTON AGAIN 1 Press and hold the Channel Push Button for several seconds. The red channel LED will begin to flash. If any relays are currently controlled by that channel, their LEDs will begin to flash as well. 2 Select the relays to be controlled. The LED for each relay “smartwired” to the channel input selected will be flashing on/off. Press the associated Relay Control Button to add/delete that relay to/from the group. 3 Press the Channel Push Button again. The LEDs will stop flashing and the channel will now control the relays selected. Test by pressing the Channel Push Button to toggle the group on/off/on. The channel LED will track the last action. Now turn off each relay in the group using the individual Relay Control Buttons. When the last relay is turned off, the channel LED should also go off. 5 HBMS8SS Building Management System Interface Module — Installation and Setup Channel Status Data Entry After power-up, the screen will display the current states of the eight global channels on the SS network as shown below. Data entry for the BMS Interface module simply involves entering scenario data and defining the contacts for each channel, as documented on the BMS Interface Module Automation Scenarios form (see Figure 2 on page 4). Once that’s been done, the module has all the information necessary to control the Smartwired Switching System. + – All relays On All relays Off M Mixed state (some On, some Off) (Blank) Channel not Smartwired to any relays The LEDs for each channel on the face of the BMS Interface Module may also light up. LED indication reflects the states associated with the input contacts, and not the actual state of the channels (actual composite channel state is shown on the Channel Status screen). Channel Input LEDs on the face of the BMS Interface Module indicate: Flashing Red Channel in Program mode Steady Red Input Contact is Closed Off Input Contact is Open Steady Green Channel in Egress Delay The HBMS8SS Keypad The BMS Interface Module’s keypad is composed of three keys as follows: UP and DOWN keys for modifying data fields. A NEXT key which confirms data entries and advances to the next appropriate screen or data field. Channel Status Screen To illustrate the data entry process, we’ll use the actual data from the sample application defined on page 3 and shown in Figure 1. 6 A Use the UP or DOWN key to toggle between YES or NO to enable or disable the Blink Warn feature. When ready, press NEXT. Egress Time: 000 Minutes A Interior Lighting Channel A – Manual ON/Scheduled OFF To begin programming a channel, press and hold the channel button on the face of the BMS Interface Module. The LED above the button begins to flash RED and the screen displays: Set the Egress Time in the same way using the UP or DOWN key. (000 for none, 001 for test, 010 to 240 in 10-minute increments). For channel A in this example, no egress time is desired, so leave the flashing field at 000 and press NEXT. Contact Definition Scenario for A Man ON / Sch OFF The field that can be modified, in this case the scenario choice in the second line, will be flashing. Use the UP or DOWN key to toggle the scenario between Sch ON/OFF and Man ON/Sch OFF. If a Photocell Control Module is also connected to the system, the Dark ON/OFF and Dark ON/Sch OFF scenarios will also be available. When the correct scenario appears on screen, press the NEXT key to select that choice and advance to the next screen: Time Delay: 120 Minutes Channel Button & Channel Input LED Blink Warn? YES A Use the UP or DOWN key to enter the length of the override Time Delay (in 10minute increments up to 240 minutes) for relays Smartwired to this channel. When correct, press NEXT. Once the scenario data has been entered, the final step in channel programming is to define the properties of the Input Contact coming from the BMS or other system, and the Status Contact reporting back to the BMS, pilot light or other system. Input Contact: A Closed =Occupied The Input Contact is defined as either Open or Closed (dry contact, maintained – see Figure 4 on page 5) to indicate that the lighting controlled by this channel should be considered Occupied. Toggle between these choices using the UP or DOWN key. When the correct option is flashing, press NEXT to select and advance to the next screen. HBMS8SS Building Management System Interface Module — Installation and Setup Exterior Lighting Status Contact:A Closed = Any ON The Status Contact can also be defined depending on what feedback is required by the BMS system. Choices for the Closed contact definition include: • Any ON (when any relays in any Channel A in any panel are on, the status contact will be closed) • All ON (every relay in every Channel A must be on for the status contact to be closed) • All OFF (every relay in every Channel A must be off for the status contact to be closed) • Any OFF (when any relays in any Channel A in any panel are off, the status contact will be closed) Programming for Channel A is now complete. Press NEXT to SAVE Channel A Program Changes. (If you need to start over, use the UP or DOWN key to change SAVE to CANCEL and press NEXT.) Set the definition of the Status Contact for Channel C as before and press NEXT. Photocell Control Module The two “Dark” scenarios only appear as options in the BMS Interface Module when the HPCU8SS Photocell Control Module is connected to the dataline. For detailed instructions on wiring the HPCU8SS and its associated HPSA Photocell Sensor, refer to instructions INHPCP8 for those units. Channel C – Dark ON/OFF The security lighting associated with Channel C in our example is to turn on every night and turn off every morning. In this example, “Dark” is defined as 20 footcandles. Begin programming Channel C as before, by pressing and holding the button marked C on the face of the BMS Interface Module. Scenario for Dark ON Saving Channel A Dark=(2-200fc) C 020 The data entry procedure for Channel B in our example follows the same steps as Channel A. Parking lot lighting should turn on when it is dark and turn off after the building is unoccupied. With this scenario, the lighting will only be turned on if the building is occupied and it is “dark.” Again, we defined dark in this example as 20 fc. An egress delay allows the parking lot lighting to stay on for a defined period of time after the building goes “unoccupied,” to allow safe exit for occupants. C SAVE Channel A Program Changes Channel B – Scheduled ON/OFF Channel D – Dark ON/Scheduled OFF Scenario for D Dark ON /Sch OFF The scenario choice in the second line, will be flashing. Using the UP or DOWN key, toggle through the scenario choices until Dark ON is displayed. Press NEXT:. After a brief message, the BMS Interface Module will return to its main Channel Status Screen. Press NEXT again to SAVE programming for Channel C, or use the UP or DOWN key to toggle to CANCEL and start again. To program this scenario, press and hold channel button D on the face of the BMS Interface Module. The scenario line will be flashing as before. Using the UP or DOWN key, toggle through the scenario choices until Dark ON/Sch OFF is displayed. Press NEXT. Egress Time: 060 Minutes D The flashing second line will prompt for a footcandle setting from 002 to 200 in 1 fc increments. Press the UP or DOWN key to scroll through the numbers until the desired footcandle level is reached (Hint: Hold down the UP or DOWN key to scroll continuously). Press NEXT: Using the UP or DOWN key, set the Egress Delay time for Channel D for 000, 001, or from 010 - 240 minutes in 10 minute increments. In this example, the egress delay is one hour, or 060 minutes. Press NEXT. With the Dark ON/OFF scenario, there is no need for an Input Contact, since there is no reference to building occupancy. The only criterion for lights turning on or off is exterior light level. (Security lighting will turn on when it’s dark, whether the building is occupied or not). As in the previous example, the flashing second line will prompt for a footcandle setting from 002 to 200 fc. Use the UP or DOWN key to scroll through the numbers until the desired footcandle level is reached. Press NEXT. continued on next page 7 HBMS8SS Building Management System Interface Module — Installation and Setup Set the definition of the Input and Status Contacts for Channel D as shown in the Channel A example and press NEXT. Choose SAVE or CANCEL and press NEXT. Testing When data entry is complete, be sure to return to the Channel Status screen. The BMS Interface Module must be displaying this screen for the scenarios to operate properly. A B C D E F G H + M – – Using the Relay Schedule forms, confirm that the correct relays are Smartwired to each channel in their panels. Confirm that each channel in the BMS Interface Module program has the proper scenario entries and contact definitions. For each channel, press the button on the face of the unit and sequence through the entries using the NEXT key to verify that all data has been entered correctly. When you have confirmed the data for each channel, you can run a real-time test using input from the BMS system. Or simulate the BMS input for each channel by using a two-wire maintained switch to open or close the contacts and observe how the channel responds. For the two “Dark” (exterior lighting) scenarios, detailed procedures for testing using the Photocell Control Module are included in the instructions INHPCP8. Panel Division 888-852-2778 INHBMS 091301 ">
/
ডাউনলোড
শুধু একটি বন্ধুত্বপূর্ণ অনুস্মারক। আপনি এখানে সরাসরি নথিটি দেখতে পারেন। তবে সবচেয়ে গুরুত্বপূর্ণ, আমাদের এআই ইতিমধ্যে এটি পড়েছে। এটি জটিল বিষয়গুলিকে সহজ শর্তে ব্যাখ্যা করতে পারে, যেকোনো ভাষায় আপনার প্রশ্নের উত্তর দিতে পারে এবং এমনকি দীর্ঘতম বা সবচেয়ে জটিল নথিগুলিকে দ্রুত নেভিগেট করতে আপনাকে সহায়তা করতে পারে।
বিজ্ঞাপন