Extron TLI Pro 201 Setup guide
Extron electronics TLSI 201 centralizes information about the TouchLink scheduler system, allowing users to book rooms and manage their schedules. It simplifies room scheduling by providing a user-friendly interface for employees to reserve meeting spaces, check availability, and receive notifications. The TLSI 201 enables efficient room management, improves collaboration, and enhances productivity in the workplace.
PDF
Документ
Реклама
Реклама
Product Category T: TANom for thlaetion R O stal IMP ron.c t e in and w.ex ng th o ww er guide onnecti ce. t o G us efore c r sour e b plete com ructions the pow o t t s t in uc prod TLI Pro 201 and TLSI 201 • Setup Guide Overview The Extron TLI Pro 201 is a TouchLink® Interface scaler that integrates a third-party touchscreen display as a point of control within an Extron Pro series control system. The scaled output supports resolutions up to 4K @ 30 Hz. The Extron TLI Pro 201 provides annotation features that allow users to draw, point, or type on video sources during presentations. The TLSI 201 is a display interface that centralizes information about the TouchLink scheduler system. This guide provides instructions for experienced installers to mount and install the TLI Pro 201 or TLSI 201 and to create a basic configuration. For more complete instructions, see the TLI Pro 201 and TLSI 201 User Guide, at www.extron.com. Setup Checklist Get Ready Download and install the latest version of the following software: Toolbelt — Provides device discovery, device information, firmware updates, and configuration of network settings, system utilities, and user management for TouchLink Pro devices. TLI Pro 201 GUI Designer — For designing layouts for third party touchpanel interfaces. Global Configurator® Professional and Global Configurator Plus — For setting up and configuring the control processor and interface. Global Scripter® — Provides an integrated development environment for Extron control systems programming. TLSI 201 Room Agent™ — Room booking software for configuring the TLSI 201 for room scheduling. NOTE: All five software programs are available from www.extron.com. Obtain the following network information from your network administrator: DHCP status — (on or off). If DHCP is off, you must also obtain: IP address Subnet mask Gateway User name — This can be either admin or user. Password — The factory configured passwords for all accounts on this device have been set to the device serial number. Passwords are case sensitive. NOTE: If the device is reset to default settings, the password will be the default password configuration. The default password is extron (for either admin or user). Make a note of the interface MAC address. Mount and Cable All Devices Mount the units. Place the interface on a convenient surface, mount it in a standard rack, or use an under-table mounting kit (see the TLI Pro 201 and TLSI 201 User Guide, at www.extron.com). To mount the third-party touchpanel follow the instructions provided by the manufacturer. Connect cables to the interface (see Rear Panel Connectors and Features on the next page). Connect the required HDMI source to the HDMI input (TLI Pro 201 only). Connect the HDMI output from the interface to the third-party touchpanel. Connect the USB port from the interface to the third-party touchpanel. NOTE: The USB connection passes information to the interface about where on the screen the touchpanel was pressed. To use a normal monitor, instead of a touchscreen, connect a mouse to the USB connection. Use the mouse to click on screen icons. 1 TLI Pro 201 and TLSI 201 • Setup Guide (Continued) Connect the Ethernet cable. The interface must be powered by PoE+. ATTENTION: Do not power on the TLI Pro 201 or TLSI 201 until you have read the Attention in the Rear Panel Features section of the TLI Pro 201 User Guide. Ne branchez pas le TLI Pro 201 ou le TLSI 201 avant d’avoir lu la mise en garde dans la section « Rear Panel Features » du TLI Pro 201 User Guide. • • Set up the Interface for Network Communication Connect the PC that you will use for setup on the same Ethernet subnetwork as the interface. If you are using the TLI Pro 201, you must also connect a control processor to the same subnetwork. The TLSI 201 does not require a control processor. Use the Setup Menu (see page 4) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask, gateway, and related settings for the network interface. Configure the User Interface TLI Pro 201 — The Global Configurator Professional Help File, the Global Configurator Plus Help File, and the GUI Designer Help File provide step‑by-step instructions and more detailed information. The Global Configurator Professional and Global Configurator Plus help files include an introduction to the software and sections on how to start a project and configuration. TLSI 201 — Use Room Agent to configure the TLS touchpanels. For complete instructions about configuring the TLSI 201, see the Room Agent Help File, User Guide, and Quick Start Guide at www.extron.com. Rear Panel Connectors and Features The TLI Pro 201 and TLSI 201 have identical rear panels. For complete information about the rear panel connectors and features, see the TLI Pro 201 and TLSI 201 User Guide. INPUT OUTPUT USB LAN/PoE+ A B C D Figure 1. TLI Pro 201 Rear Panel ATTENTION: • • A The TLI Pro 201 and TLSI 201 are Power over Ethernet (PoE 803.3at, class 4) compliant. Do not connect the power supply before reading the Attention in the Rear Panel Features section of the TLI Pro 201 and TLSI 201 User Guide. Le TLI Pro 201 et le TLSI 201 supportent l’alimentation via Ethernet (PoE 803.3at, classe 4). Veuillez lire la partie « Attention » dans la section « Rear Panel Features » du TLI Pro 201 and TLSI 201 User Guide, avant de mettre sous tension les écrans tactiles. HDMI input (TLI Pro 201 only) — Plug the cable from the input source device into this female HDMI type A port. Use the provided LockIt HDMI lacing bracket to secure the HDMI connector: 1. Plug the HDMI cable into the panel connection. 2. Loosen the HDMI connection mounting screw from the panel enough to allow the LockIt lacing bracket to be placed over it. The screw does not have to be removed. 3. Place the LockIt lacing bracket on the screw and against the HDMI connector, then tighten the screw to secure the bracket. 1 2 3 ATTENTION: • • Do not overtighten the HDMI connection mounting screw. The shield it fastens to is very thin and can easily be stripped. Ne serrez pas trop la vis de montage du connecteur HDMI. Le blindage auquel elle est attachée est très fin et peut facilement être dénudé. 4. Loosely place the included tie wrap around the HDMI connector and the LockIt lacing bracket as shown. 5. While holding the connector securely against the lacing bracket, tighten the tie wrap, then remove any excess length. 4 3 5 Figure 2. Securing the HDMI Connector Product Category B C HDMI output (see figure 1 on the previous page) — Connect this female HDMI type A port to a third-party touch screen. A full list of compatible resolutions is provided in the TLI Pro 201 and TLSI 201 User Guide. Use the provided LockIt brackets to secure the connector to the TLI Pro 201 or TLSI 201 unit (see HDMI input, on the previous page). USB port — supports High-speed USB 2.0 control. Plug a Type-A USB cable from the third-party touchpanel into this port. NOTE: To use a monitor that is not a touchpanel, connect a mouse to this port. D LAN and PoE+ port — Use an Ethernet cable to connect this port to the network via a PoE+ power sourcing equipment (PSE, not provided). This can be a power injector (see figure 3) or PoE+ switch. NOTE: These interfaces are shipped without a PoE+ PSE. This must be purchased separately. Extron recommends the Extron PI 140 power injector (see figure 3). Your power injector may look different. 1. Use an Ethernet cable to connect the LAN/PoE+ port of the interface to the power output of the 803.3at, class 4 compliant PoE+ power injector. 2. Connect the network input of the power injector to a network switch or router. Alternatively, use an Ethernet cable to connect the LAN/PoE+ port of the interface to a PoE+ switch. 100-240V 50/60 Hz 1.1A MAX INPUT OUTPUT LAN POWERED TLP To network switch To interface Figure 3. PI 140 Power Injector Front Panel Features INPUT R MENU OUTPUT SIGNAL HDCP A BC TLI Pro 201 D Figure 4. TLI Pro 201 Front Panel A B Power LED — Indicates the power status and the reset status of the unit. C Menu button (recessed) — opens the Setup Menu (see the next page) and Calibration screen for the interface: Reset button (recessed) — allows the unit to be reset in any of three different modes. It also allows the user to toggle between enabling and disabling the DHCP client. A brief summary of the reset modes is given below. For more information see the TLI Pro 201 and TLSI 201 User Guide. Press the button briefly (less than 2 seconds) to open the internal menu screens. Press and hold the button (at least 2 seconds) to open the Calibration screen. Follow the on-screen instructions to calibrate the touchpanel. • Press the button briefly (less than 2 seconds) for a second time to close the current screen without saving any changes. Status LEDs — • • D • • The Signal LEDs light green when a video signal is detected and are unlit when no signal is detected. The HDCP LEDs light green when HDCP content is detected and are unlit when HDCP content is not detected. 3 TLI Pro 201 and TLSI 201 • Setup Guide (Continued) Reset Modes: a Brief Summary The TLI Pro 201 and TLSI 201 offer the following reset modes: • Use factory firmware: Press and hold the Reset button (Figure 4, B) while applying power to the unit. Use this mode to replace firmware in the event of firmware failure. • Reset All IP Settings: Press and hold the Reset button for 6 seconds. After the Power LED (Figure 4, A) flashes twice, release and momentarily press the Reset button. Use this mode to reset all network settings without affecting user-loaded files. • Reset to Factory Defaults: Press and hold the Reset button for 9 seconds. After the Power LED flashes three times, release and momentarily press the Reset button. Use this mode to return the device to factory default settings. NOTES: • The factory configured passwords for all accounts on this device have been set to the device serial number. Passwords are case sensitive. • If the device is reset to default settings, the password is the default password configuration. The default password is extron. • Enable or Disable the DHCP This mode toggles between DHCP enabled and DHCP disabled. Press the Reset button Client: five times, consecutively. After the fifth press, do not press the button again within 3 seconds. If DHCP was enabled, it is now disabled and the Power LED blinks three times. If DHCP was disabled, it is now enabled and the Power LED blinks six times. Setup Menu Press the Menu button (see Front Panel Features, C on page 3) to open the setup menu (see figure 5). There are six available screens that are selected by pressing the appropriate button in the navigation bar at the top of the screen. • • The Status screen is read-only and provides a summary of the other screens. The Network screen is used to edit the network settings (DHCP setting, IP, subnet mask and gateway addresses). • The Output screen is used to configure the image shown by the third-party display, using built-in test patterns and EDID. • The Audio screen is used to set audio levels. • The Input screen is used to configure the input video signal. • The Advanced screen provides information about the system and the GUI project Status Network TLI Pro 201 Part Number: 60-1669-01 Firmware Version: 1.00 Bootloader Version: 1.00 PoE Status: Active Input Advanced Network Info Model: Audio Output IP Address: 192.168.254.251 DHCP: Off Host Name: TLI-AB-CD-EF Output TLI Output: GUI Project: Sleep Timer: Audio Master Volume: 99 Master Mute: Off Exit 1080p @ 60Hz 1080p @ 60Hz 5 Minutes Input HDMI: No Signal Advanced Controller IP: 192.168.254.250 Project Size: N/A Figure 5. Setup Menu Press the Exit button to close the setup menu. For more information about the setup menu, see the TLI Pro 201 and TLSI 201 User Guide at www.extron.com. For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide on the Extron website. 4 © 2020 Extron Electronics — All rights reserved. www.extron.com All trademarks mentioned are the property of their respective owners. Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876 68-3514-50 Rev. A 02 20 ">
/
Скачать
Просто дружеское напоминание. Вы можете просмотреть документ прямо здесь. Но самое главное, наш ИИ уже прочитал его. Он может объяснить сложные вещи простыми словами, ответить на ваши вопросы на любом языке и помочь вам быстро перемещаться даже по самым длинным или сложным документам.
Реклама