advertisement
▼
Scroll to page 2
of 10
UTZ-BD025C UTZ-BD035C UTZ-BD050C UTZ-BD080C UTZ-BD100C If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involves. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Make sure to disconnect the power plug before cleaning the product. RA EA RA OA SA A A EA OA 600 600 SA Model UTZ-BD035C and UTZ-BD050C have two Heat Exchange Elements. UTZ-BD100C UTZ-BD025C UTZ-BD080C UTZ-BD035C UTZ-BD100C 20 UTZ-BD050C UTZ-BD080C UTZ-BD035C UTZ-BD050C 370 UTZ-BD100C (kg/kg’) A UTZ-BD025C ■Cable for supply cord : VVF cable with Φ1.6 or Φ2. Cable for connecting main unit and remote controller : 300V/500V , 60227IEC10 (hard wire). Cross-section area for each core wire is 1.5mm2. FY-250ZDY8 6 9 10 Number 1 2 3 4 5 6 7 8 9 10 11 12 13 F G H A I H E G 5 2 FY-350ZDY8 UTZ-BD025C UTZ-BD035C FY-500ZDY8 UTZ-BD050C 7 1 11 K 4-13×30 Oval hole ⑬ L M B J C UTZ-BD035C UTZ-BD050C C Quantity Note 1 Adapter 4 Terminal 1 Inspection Cover 1 Fan 2 Motor 2 Note2) Heat Exchange element 1 Note1) Filter 2 Damper 1 Damper Motor 1 Ceiling Suspension Fixture 4 Electrical Equipment Box 1 Energy RecoveryVentilator Remocon 1 Note1) Model No.UTZ-BD035C and UTZ-BD050C have two Heat Exchange Elements. Note2) Model No.UTZ-BD035C and UTZ-BD050C have different fan and motor locations. UTZ-BD025C P N 4 3 Name Frame 8 UTZ-BD025C 414 UTZ-BD035C 1050 70 978 112 580 470 182 317 UTZ-BD050C 1090 70 1018 132 640 470 182 317 2 6 8 E 10 9 FY-01KZDY8A G H I F A H 5 G FY-650ZDY8 UTZ-BD080C UTZ-BD100C FY-800ZDY8 1 7 ⑬ 11 L M B J N P UTZ-BD080C UTZ-BD100C 8 UTZ-BD080C UTZ-BD100C 1 2 3 4 5 6 7 8 9 10 11 12 13 Name Quantity Note Frame 1 Adapter 4 Terminal 1 Inspection Cover 1 Fan 2 Motor 2 Heat Exchange element 3 Filter 2 Damper 1 Damper Motor 1 Ceiling Suspension Fixture 4 Electrical Equipment Box 1 Energy RecoveryVentilator Remocon 1 Note1) Note1) Model No.UTZ-BD100C has four Heat Exchange Elements. 3 4 C K Number C Ask a specialized electrical construction operator for advice regarding wiring in accordance with "Technical Standards for Electrical Equipment"and"Interior Wiring Regulation". Connect wires/cables indicated by broken lines. UTZ-BD025C Hi Lo For power supply,use a VVF cable with 1.6 or 2. Take the following steps on connect wires/cables: Remove two screws fixing the cover of the electrical components box,open the cover ,and connect wires/cables correctly. Secure the cable drawn from the terminal board firmly with the cable holder. If a large volume of air is requierd or a long duct is used ,switch the wire connection from Low to Extra high according to the following steps: Remove two screws securing the cover of the electrical components box, and open the cover . In the electrical components box,change the connection of fan motor leads from High to Extra high. UTZ-BD035C 3.5 UTZ-BD050C 6.0 Hi Lo UTZ-BD080C 10.0 UTZ-BD100C 10.0 Relay 4 Hi Lo When operating multiple air-to-air heat exchange units using a single switch ,the maximum number of units able to be operated is 10. Be sure to use the appropriate power supply corresponding to each model number,Using an inappropriate power supply may cause the motor to burn out. Grounding work must be based on Class D as defined in "Technical Standards for Electrical Equipment". After wire connections are completed ,check the connection again before turning the power on. Model No. UTZ-BD080C,UTZ-BD100C, two Fan Motors are stopped during an operation of the damper. Pursuant to at the directive 2014/30/EU,article 9(2) Printed in China Gedruckt in China Imprimé en Chine Impreso en China Stampato in Cina Impresso na China 25ZDY8RFG0854 P0917-0
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement