Mastervolt C3-RS User manual


Add to my manuals
3 Pages

advertisement

Mastervolt C3-RS User manual | Manualzz
ASTER ISION MODULAR SWITCHBOARDS
HOW TO ASSEMBLE A MASTERVISION PANEL
connector bar
07-09-07810
1. For best results, use Mastervision installation parts
2. Use connector bar 07-09-07810 and connector block
07-09-07820 to assemble the panel.
3. The mounting bolts used are M4x25
4. Secure the bolts wit hte supplied M4 nuts and O-rings.
5. To fasten the electrical panel in its frame or bulkhead use
the the stencil as supplied to cut the panelhole.
6.
connector block
07-09-07820
Do not use connector blocks at the outside top or
bottom edge. This is where the complete panel
will be fastened to its frame or bulkhead.
10/30V DC power supply for backlight
HOW TO INSTALL THE BACKLIGHTING SYSTEM:
Indicator wire to
load side of breaker
The Mastervision panels have a two-state backlight system for label illumination.
The first state is a low intensity green light that illuminates the labels on the
panel to enable label viewing in low light conditions, any time the circuit is
switched ON or OFF. The second state is a higher intensity yellow DC LED
(or orange neon lamp for AC) to indicate when a circuit is switched ON.
Power must be fed to all modules with backlight capability. This is achieved by
linking all the modules together by their backlight connectors (see drawing).
Verify the backlight AC or DC voltage on each module.
Note:
The power supply voltages are equal on all backlight modules,
indicator voltages are depending on the type of panel.
backlight
5 DC
busbar
for 5 breakers
HOW TO LABEL A BACKLIGHT
DC MODULE
To place the labels on the backlight module
remove the mounting bolts and turn the module
around.
Place the label in the embossed square on the
lens. Make sure that the label is placed
correctly and the indicator led is
uncovered.
Replace the backlight module in the
original position.
connect the indicator
wire to the load side of
the breaker
10/30V power supply
Warning:
When the module is placed correctly the
indicator led is 1mm away from the
transparant front lens.
1mm
AC MODULE
NAVIGATION
INSTRUMENTS
L phase
N neutral
1mm
10/30V power supply
CAUTION
GENERAL
1. Lethal voltages exist on your vessel. Make sure all shore power, onboard
generating sources and batteries are disconnected before beginning
installation of your electrical panel.
2. AC modules will have lethal voltages on the bus bars and terminals.
Additional safety enclosures as the AC protection shield (part no. 07-09-04601-2-3)
may be required in some installations.
3. Make sure all Ac modules are bonded tot the ship’s AC ground bus. When
grouping modules together to form your panel, a single ground may be used.
Use an ohm meter to verify ground to all modules.
1. Verify the modules you purchased arev configured for the source voltage
aboard your vessel / mobile. Refer to the backlight specification.
2. Installation of Mastervision panels should be completed by a person with
a thorough knowledge of marine / mobile electrical systems.
3. Wiring to and from each module should be conform to the local applicable
standards and taking into consideration the safety guidelines and measures.
Mastervolt can accept no liability for damage due to the use of the panel or
due to possible errors in the manual and the results thereof.
backlight module 5 labels 12/24V DC
backlight module 2 labels 12/24V DC
backlight module 5 labels 230V AC
backlight module 2 labels 230V AC
LED 12/24V 3mm flathead yellow (prewired) 10 each
LED 12/24V 3mm flathead green (prewired) 10 each
LED 12/24V 3mm flathead red (prewired) 10 each
LED 12/24V 3mm flathead (4 x yellow/ 4 x green/ 2 x red)
neon lamp 230V 6mm orange (prewired) 10 each
circuit breaker type rocker CD 1 pole max 100A red
circuit breaker type rocker CD 2 pole max 100A red
circuit breaker type rocker CD 1 pole max 190A red (B-3-BS)
circuit breaker type rocker MD 1 pole max 25A red
panel hole plug A series rocker
panel hole plug M series rocker
07-09-052xx
07-09-053xx
07-09-05301
07-09-052xx
07-09-05600
07-09-05610
= breaker current value
circuit breaker type rocker AD 1 pole max 50A red with fingerguard
circuit breaker type rocker AD 1 pole max 50A red push to reset
07-09-05091
07-09-05093
xx
circuit breaker type rocker AD 1 pole max 50A red
circuit breaker type rocker AD 2 pole max 50A red
07-09-050xx
07-09-051xx
CIRQUIT BREAKERS CARLINGSWITCH
07-09-04310
07-09-04312
07-09-04320
07-09-04322
07-09-04400
07-09-04402
07-09-04404
07-09-04406
07-09-04500
BACKLIGHT MODULES
INSTALLATION ACCESSORIES
rockerswitch on-off 8A black
rockerswitch on-off-on 8A black
07-09-04601
07-09-04602
07-09-04603
Mastervolt/22-04-00
[email protected]
labelsheet 1 with 143 labels englisch
labelsheet 2 with 143 labels dutch
labelsheet 3 with 143 labels french
labelsheet 4 with 143 labels german
AC protectionshield for panel 1
AC protectionshield for panel 2
AC protectionshield for panel 3
mass
charger
panel lights
main
breaker
outlets
AC 220 V
terminal screws - hex. 10/32 -for breakers AD series (10 each)
terminal screws - hex. 8/32 - for breakers MD series (10 each)
connector bar 145x20mm to connect 3 panels
connector block 25x20mm to connect 2 panels
bus bar to connect 2 breakers
bus bar to connect 5 breakers
AC PROTECTION SETS
07-09-07910
07-09-07920
07-09-07930
07-09-07940
LABELSHEETS
07-09-05700
07-09-05710
07-09-07810
07-09-07820
07-09-07840
07-09-07830
INSTALLATION COMPONENTS
07-09-07610
07-09-07620
PANEL SWITCHES
MASTERVOLT SNIJDERSBERGWEG 93 , 1105 AN AMSTERDAM THE NETHERLANDS WWW.MASTERVOLT.COM
ASTER ISION MODULAR SWITCHBOARDS
130
6
Serie 1
240x130mm
Serie 2
120x130mm
Serie 3
120x65mm
Serie 4
60x65mm
copy this paper and assemble the panel on paper
tape the paper-panel on the background
drill the mounting holes
cut the panel hole
maximum panel depth 120 mm
1.
2.
3.
4.
NOTE: To dimension the panel cut out, follow these steps:
drill 5mm
240
228
1
0,75
0,75
0,75
0,75
0,75
0,75
0,75
1,5
1,5
1,5
Amp
1
2
3
4
5
6
7
8
9
10
0,75
0,75
0,75
0,75
0,75
0,75
1,5
1,5
1,5
1,5
2
0,75
0,75
0,75
0,75
0,75
1,5
1,5
1,5
1,5
2,5
3
0,75
0,75
0,75
0,75
1,0
1,5
1,5
2,5
2,5
4
4
108
120
0,75
0,75
0,75
1,0
1,5
1,5
2,5
2,5
4
4
5
0,75
0,75
0,75
1,5
1,5
2,5
2,5
4
4
4
6
length in meters
65
0,75
0,75
1
1,5
2,5
2,5
4
4
4
6
7
0,75
1
1,5
2,5
2,5
4
4
4
6
6
8
0,75
1
1,5
2,5
4
4
4
6
6
6
9
0,75
1,5
2,5
4
4
4
6
6
6
6
10
48
1
1,5
2,5
4
4
6
6
6
10
10
15
1,5
1,5
4
4
6
6
10
10
10
10
20
6
Mastervolt/ 22-04-00
53
PANEL CUT OUT SIZING (dimensions in mm)
ASTER ISION MODULAR SWITCHBOARDS
118

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement