Specification

HEAT PUMP CONDENSER - Outdoor Model

Max Number of Zones

V/Hz/Ph Power Supply

SEER

Minimum Circuit (Disconnect)

Maximum Fuse (Breaker)

Net Dimensions (WxDxH)

Packaging Dimensions (WxDxH)

Net Weight

A

A in in lbs

Outdoor Gross Weight lbs

WALL MOUNTED - Indoor Model

Power Supply

Minimum Circuit (Disconnect)

Maximum Fuse (Breaker)

Net Dimensions (WxDxH)

Packaging Dimensions (WxDxH)

Net Weight

A in

V/Hz/Ph

A in lbs

MULTI2-18HP230V1

2

208-230/60/1

22.5

18

25

33.27x14.29x27.64

37.99x15.55x29.72

105.82

114.64

O-09-HP-WMAH-230A

208-230/60/1

9

15

32.87x7.80x11.02

35.83x10.63x13.98

19.8

lbs in

Gross Weight

Piping Size Liquidside/Gasside

CEILING CASSETTE - Indoor Model

Power Supply

Minimum Circuit (Disconnect)

Maximum Fuse (Breaker)

Net Dimensions (WxDxH)

Packaging Dimensions (WxDxH)

Net Weight

Gross Weight

Piping Size Liquidside/Gasside

CEILING RECESSED - Indoor Model

Power Supply

Minimum Circuit (Disconnect)

Maximum Fuse (Breaker)

Net Dimensions (WxDxH)

Packaging Dimensions (WxDxH)

Net Weight

Gross Weight

Piping Size Liquidside/Gasside

A in in

V/Hz/Ph

A lbs lbs in

A in in

V/Hz/Ph

A lbs lbs in

25.4

1/4"-3/8"

CASSETTE12HP-230

208-230/60/1

1.3

15

22.44x22.44x10.24

25.79x25.79x11.42

35.27

41.88

1/4"-1/2"

DUCT-09HP-230

208-230/60/1

1.2

15

27.56x25x8.27

36.02x25.79x11.42

39.9

50.27

1/4"-3/8"

Superior Performance

MULTI3-27HP230V1

3

208-230/60/1

23

25

35

37.24x16.14x31.89

42.91x19.69x34.06

149.91

160.94

O-12-HP-WMAH-230A

208-230/60/1

9

15

32.87x7.80x11.02

35.83x10.63x13.98

19.8

25.4

1/4"-1/2"

CASSETTE18HP-230

208-230/60/1

1.9

15

22.44x22.44x10.24

25.79x25.79x11.42

39.68

46.3

1/4"-1/2"

DUCT-12HP-230

208-230/60/1

1.3

15

27.56x25x8.27

36.02x25.79x11.42

39.9

50.27

1/4"-1/2"

MULTI4-36HP230V1

4

208-230/60/1

22.5

30

45

37.24x16.14x31.89

42.91x19.69x34.06

156.53

167.55

O-18-HP-WMAH-230A

208-230/60/1

18

25

38.98x8.58x12.40

41.93x11.81x15.75

26.9

34.8

1/4"-1/2"

CASSETTE24HP-230

208-230/60/1

10.3

17.5

33.07x33.07x8.07

35.43x35.43x8.54

45.19

52.91

3/8"-5/8"

DUCT-18HP-230

208-230/60/1

1.9

15

36.22x25x8.27

44.68x25.79x11.42

50.7

63.93

1/4"-1/2"

E

MULTI5-48HP230V1

5

208-230/60/1

22.4

35

50

37.48x16.34x52.48

43.11x19.49x54.53

223.77

255.07

O-24-HP-WMAH-230A

208-230/60/1

20

30

46.69x10.16x13.39

49.80x16.53x13.39

40.1

50.3

3/8"-5/8"

DUCT-24HP-230

208-230/60/1

2.5

15

36.22x25x10.63

44.68x25.79x13.78

57.32

68.34

3/8"-5/8"

Specification - Match-Ups

MULTI2-18HP230V1 (18K) - 2 COMBINATIONS

Two Units

9K + 9K 9K + 12K *

MULTI3-27HP230V1 (27K) - 11 COMBINATIONS

Two Units Three Units

9K + 9K 12K + 12K 9K + 9K + 9K 9K + 12K + 12K *

9K + 12K

9K + 18K

12K + 18K * 9K + 9K + 12K * 12K + 12K + 12K *

18K + 18K * 9K + 9K + 18K *

MULTI4-36HP230V1 (36K) - 27 COMBINATIONS

Two Units Three Units

9K + 18K 12K + 24K 9K + 9K + 9K 9K + 12K + 24K *

9K + 24K 18K + 18K 9K + 9K + 12K 9K + 18K + 18K *

12K + 12K 18K + 24K * 9K + 9K + 18K 12K + 12K + 12K

12K + 18K 24K + 24K * 9K + 9K + 24K * 12K + 12K + 18K *

9K + 12K + 12K 12K + 12K + 24K *

9K + 12K + 18K * 12K + 18K + 18K *

Four Units

9K + 9K + 9K + 9K 12K + 12K + 12K + 12K *

9K + 9K + 9K + 12K *

9K + 9K + 9K + 18K *

9K + 9K + 12K + 12K *

9K + 9K + 12K + 18K *

9K + 12K + 12K + 12K *

MULTI5-48HP230V1 (48K) - 28 COMBINATIONS

Two Units Three Units

9K + 24K

12K + 24K

18K + 18K

18K + 24K

24K + 24K

9K + 9K + 18K

9K + 9K + 24K

9K + 12K + 12K

9K + 12K + 18K

12K + 12K + 12K

12K + 12K + 18K

12K + 12K + 24K

12K + 18K + 18K

9K + 12K + 24K

9K + 18K + 18K

18K + 18K + 18K *

Four Units

9K + 9K + 9K + 9K

Five Units

12K + 12K + 12K + 18K * 9K + 9K + 9K + 9K + 9K

9K + 9K + 9K + 12K

9K + 9K + 9K + 18K

9K + 9K + 12K + 12K

9K + 9K + 12K + 18K

9K + 12K + 12K + 12K

9K + 9K + 9K + 9K +12K

9K + 9K + 9K + 12K + 12K *

9K + 12K + 12K + 18K *

12K + 12K + 12K + 12K

Note: It is critical to size the outdoor unit for the entire building load and each indoor unit for it’s individual zone load.