MRCOOL M336HP23WM01AK2 Olympus 30,000 BTU 2.5 Ton 3-Zone Ductless Mini-Split Air Conditioner and Heat Pump, 25 ft. Install Kit - 230V/60Hz Product Brochure
Add to my manuals
3 Pages
advertisement
Olympus Multi-Zone Series
Ductless Multi-Split Heat Pump A/C
Divine Comfort
SMART CONTROLLER
Versatile Installation
Superior Performance
7 Year Compressor
Best Features
Smartphone App Follow me ® Gold Fin ® Condenser DC Inverter
M Versatile Installation
Specification
HEAT PUMP CONDENSER - Outdoor Model
Max Number of Zones
V/Hz/Ph Power Supply
SEER
Minimum Circuit (Disconnect)
Maximum Fuse (Breaker)
Net Dimensions (WxDxH)
Packaging Dimensions (WxDxH)
Net Weight
A
A in in lbs
Outdoor Gross Weight lbs
WALL MOUNTED - Indoor Model
Power Supply
Minimum Circuit (Disconnect)
Maximum Fuse (Breaker)
Net Dimensions (WxDxH)
Packaging Dimensions (WxDxH)
Net Weight
A in
V/Hz/Ph
A in lbs
MULTI2-18HP230V1
2
208-230/60/1
22.5
18
25
33.27x14.29x27.64
37.99x15.55x29.72
105.82
114.64
O-09-HP-WMAH-230A
208-230/60/1
9
15
32.87x7.80x11.02
35.83x10.63x13.98
19.8
lbs in
Gross Weight
Piping Size Liquidside/Gasside
CEILING CASSETTE - Indoor Model
Power Supply
Minimum Circuit (Disconnect)
Maximum Fuse (Breaker)
Net Dimensions (WxDxH)
Packaging Dimensions (WxDxH)
Net Weight
Gross Weight
Piping Size Liquidside/Gasside
CEILING RECESSED - Indoor Model
Power Supply
Minimum Circuit (Disconnect)
Maximum Fuse (Breaker)
Net Dimensions (WxDxH)
Packaging Dimensions (WxDxH)
Net Weight
Gross Weight
Piping Size Liquidside/Gasside
A in in
V/Hz/Ph
A lbs lbs in
A in in
V/Hz/Ph
A lbs lbs in
25.4
1/4"-3/8"
CASSETTE12HP-230
208-230/60/1
1.3
15
22.44x22.44x10.24
25.79x25.79x11.42
35.27
41.88
1/4"-1/2"
DUCT-09HP-230
208-230/60/1
1.2
15
27.56x25x8.27
36.02x25.79x11.42
39.9
50.27
1/4"-3/8"
Superior Performance
MULTI3-27HP230V1
3
208-230/60/1
23
25
35
37.24x16.14x31.89
42.91x19.69x34.06
149.91
160.94
O-12-HP-WMAH-230A
208-230/60/1
9
15
32.87x7.80x11.02
35.83x10.63x13.98
19.8
25.4
1/4"-1/2"
CASSETTE18HP-230
208-230/60/1
1.9
15
22.44x22.44x10.24
25.79x25.79x11.42
39.68
46.3
1/4"-1/2"
DUCT-12HP-230
208-230/60/1
1.3
15
27.56x25x8.27
36.02x25.79x11.42
39.9
50.27
1/4"-1/2"
MULTI4-36HP230V1
4
208-230/60/1
22.5
30
45
37.24x16.14x31.89
42.91x19.69x34.06
156.53
167.55
O-18-HP-WMAH-230A
208-230/60/1
18
25
38.98x8.58x12.40
41.93x11.81x15.75
26.9
34.8
1/4"-1/2"
CASSETTE24HP-230
208-230/60/1
10.3
17.5
33.07x33.07x8.07
35.43x35.43x8.54
45.19
52.91
3/8"-5/8"
DUCT-18HP-230
208-230/60/1
1.9
15
36.22x25x8.27
44.68x25.79x11.42
50.7
63.93
1/4"-1/2"
E
MULTI5-48HP230V1
5
208-230/60/1
22.4
35
50
37.48x16.34x52.48
43.11x19.49x54.53
223.77
255.07
O-24-HP-WMAH-230A
208-230/60/1
20
30
46.69x10.16x13.39
49.80x16.53x13.39
40.1
50.3
3/8"-5/8"
DUCT-24HP-230
208-230/60/1
2.5
15
36.22x25x10.63
44.68x25.79x13.78
57.32
68.34
3/8"-5/8"
Specification - Match-Ups
MULTI2-18HP230V1 (18K) - 2 COMBINATIONS
Two Units
9K + 9K 9K + 12K *
MULTI3-27HP230V1 (27K) - 11 COMBINATIONS
Two Units Three Units
9K + 9K 12K + 12K 9K + 9K + 9K 9K + 12K + 12K *
9K + 12K
9K + 18K
12K + 18K * 9K + 9K + 12K * 12K + 12K + 12K *
18K + 18K * 9K + 9K + 18K *
MULTI4-36HP230V1 (36K) - 27 COMBINATIONS
Two Units Three Units
9K + 18K 12K + 24K 9K + 9K + 9K 9K + 12K + 24K *
9K + 24K 18K + 18K 9K + 9K + 12K 9K + 18K + 18K *
12K + 12K 18K + 24K * 9K + 9K + 18K 12K + 12K + 12K
12K + 18K 24K + 24K * 9K + 9K + 24K * 12K + 12K + 18K *
9K + 12K + 12K 12K + 12K + 24K *
9K + 12K + 18K * 12K + 18K + 18K *
Four Units
9K + 9K + 9K + 9K 12K + 12K + 12K + 12K *
9K + 9K + 9K + 12K *
9K + 9K + 9K + 18K *
9K + 9K + 12K + 12K *
9K + 9K + 12K + 18K *
9K + 12K + 12K + 12K *
MULTI5-48HP230V1 (48K) - 28 COMBINATIONS
Two Units Three Units
9K + 24K
12K + 24K
18K + 18K
18K + 24K
24K + 24K
9K + 9K + 18K
9K + 9K + 24K
9K + 12K + 12K
9K + 12K + 18K
12K + 12K + 12K
12K + 12K + 18K
12K + 12K + 24K
12K + 18K + 18K
9K + 12K + 24K
9K + 18K + 18K
18K + 18K + 18K *
Four Units
9K + 9K + 9K + 9K
Five Units
12K + 12K + 12K + 18K * 9K + 9K + 9K + 9K + 9K
9K + 9K + 9K + 12K
9K + 9K + 9K + 18K
9K + 9K + 12K + 12K
9K + 9K + 12K + 18K
9K + 12K + 12K + 12K
9K + 9K + 9K + 9K +12K
9K + 9K + 9K + 12K + 12K *
9K + 12K + 12K + 18K *
12K + 12K + 12K + 12K
Note: It is critical to size the outdoor unit for the entire building load and each indoor unit for it’s individual zone load.
* If all indoor units (handlers) run simultaneously, their combined BTU output will not exceed the BTU rating of the outdoor unit (condenser).