Eaton VPKA120 New VPKA Thin 20 Amp 1/2 in. 1-Pole Challenger Type A Replacement Circuit Breaker Installation Guide

Add to My manuals
1 Pages

advertisement

Eaton VPKA120 New VPKA Thin 20 Amp 1/2 in. 1-Pole Challenger Type A Replacement Circuit Breaker Installation Guide | Manualzz
T&B Distribution Equipment
Circuit Breakers — Product Installation Information
Product Description
Thomas & Betts circuit breakers are molded of a durable thermoset
plastic which is not subject to dielectric breakdown after arcing.
Operating handles are non-breakable plastic. Cases are color coded to
indicate the interrupting capacity of the breaker.
Both Type A, 1/2" per pole, and Type TB, 1" per pole, modules contain
thermal-magnetic trip units which provide fast magnetic-trip protection
against short circuits and time-delay-trip protection against overloads.
The unique side-clip design of Type A 2-pole breakers allows a true
common-trip 120/240 volt device that can be installed in a 1" mounting
space. Factory calibration after assembly assures consistent
performance when installed.
A-115 A-230
Operating Mechanisms
Breakers are supplied with quick-make, quick-break trip-free
mechanisms, which make it impossible to hold the breaker in the “On”
position against a fault or overload. When the handle is in the “Tripped”
position, midway between “On" and “Off”, it identifies a tripped condition.
Reset the breaker simply by moving the handle to the “Off” position, then
“On”. Factory-assembled two-pole breakers are common trip—one fault
trips all. Movable contact wiping action helps keep contact surfaces
clean when the breaker is operated mechanically. Arc chutes extinguish
arcs on short-circuit interruption and minimize ionized gases, while
exhaust vents guide gases harmlessly into the wiring gutter. Each pole is
individually tested, calibrated and sealed to retain its setting.
TB-115 Cutaway View
Ratings
Features
a AU tin il cer. ok. ; One and two poles, 120,120/240 and 240 volts AC, 15-60 amperes for
*Siverunsten cnc pi o action Md deceo branch breakers, 70-225 amperes for mains. Breakers rated 10,000 AIC.
contacts clean. =
* Unique side-clip design of Type A two-pole breakers gives true UL and Federal Specifications |
common trip in 1” space. В Breakers are listed by Underwriters Laboratories Inc. under UL File #£162469. They
* Self-positioning line-contact clip assures positive alignment of meet or exceed the applicable Classes of Federal Specification W-C-375B/Gen, Type
breaker to bus stab. |. They are certified by Canadian Standards Association under CSA Standard 22.2 No.
* Complete family of branch breakers allows even distribution of the et
load on A-phase and B-phase bus stabs. Box gs 370 AO 5-1963 for Service Entrance and Branch Circuit Breakers.
Copper/Aluminum terminal screws. Allows for fast and easy
straight-in wiring.
* Ampere ratings appear on every breaker handle for positive
identification.
* Factory-assembled two-pole circuit breakers contain common trip
mechanisms. A fault in one pole trips both poles independently of
the operating handle.
Plug-On Circuit Breakers Installation Instructions — Type A Breakers
1. Single Pole Breakers Supplied. 2. To Install: 3. Between Bus Stabs: Important Note:
Two single-pole breakers are Hook load end of the breaker under When required, breakers may be These circuit breakers conform to
packed in pairs for convenience. the hold-down tab in the panel. installed between bus stabs as Section 384-15 of the latest
These breakers are alike except for — Press line end of breaker down so shown in the drawing below. National Electrical Code. Install
the position of the plug-on clip that the plug-in clip slips over the only in panel positions having
which connects the breaker tothe bus stab. Insert breakers by pairs notched bus stabs.
bus stab in the panel. for easier installation.
Notched
Line End Load End Bus Stabs Bus Stabs Bus Stab
| =| =. O Right Hand Right Hand woah
— ——Right-Hand Plug-On Clip
——Left-Hand Plug-On Clip
| cami] (0
2
ea |
Left Hand
Line End Load End Mounting Unnotched
Rai Bus Stab
Type TB, IP
Left-Hand and Right-Hand Bus Stabs and Hold-Down Installation Between Bus Bus Stabs
Plug-On Clips Tabs Stabs