American Standard Townsend Single-Handle 1-Spray Tub and Shower Faucet installation Guide


Add to my manuals
4 Pages

advertisement

American Standard Townsend Single-Handle 1-Spray Tub and Shower Faucet installation Guide | Manualzz
INSTALLATION
INSTRUCTIONS
T353.500
T353.501
T353.502
T353.507
T353.508
TOWNSEND®
BATH AND SHOWER
TRIM KIT
Thank you for selecting American Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly-please
read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1M
RECOMMENDED TOOLS
Phillips Screwdriver
Plumbers’ Putty
or Caulking
Adjustable Wrench
Teflon Tape
Channel Locks
Flat Blade Screwdriver
ROUGHING-IN DIMENSIONS
• To assure proper positioning in relation to wall.
Note roughing-in dimensions.
SHR. 1/2" (13 mm) NOM.
COPPER SWEAT
FINISHED WALL
INLETS
4-1/16"
(103 mm)
SWEAT
INLETS
1-5/8" TO 3-1/4"
(41 TO 83 mm)
INLETS
1/2" (13 mm) NOM.
COPPER SWEAT
2"
(51 mm)
4-1/16"
(103 mm)
1/2" (12 mm) NPT
TUB 1/2" (13 mm) NOM.
COPPER SWEAT
3.3/8" (85 mm) REF.
74" (1880 mm)
FOR HEAD
CLEARANCE
2-9/16"
(65 mm)
SWEAT
INLETS (STOPS)
1-5/8" TO 3-1/4"
(41 TO 83 mm)
5-7/8"
(149 mm)
SHR. 1/2" (13 mm) NOM.
COPPER SWEAT
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 80''
(1651 AND 2032 mm)
7" (177 mm) REF.
4-1/16"
(103 mm)
TUB 1/2" (13 mm) NOM.
COPPER SWEAT
INLETS
1/2" (13 mm) NOM.
COPPER SWEAT
7-1/4"
(184 mm)
18" (457 mm)
OPTIONAL
INLETS 1/2" NPT
(13 mm)
3-3/8"
(86 mm)
1-1/2" REF.
(38 mm)
3-3/8"
(86 mm)
6.5" REF.
(165 mm)
TOP OF TUB RIM
BOTTOM OF TUB
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2016
4"
(102 mm)
5-7/8"
(149 mm)
INLETS
1/2" NPT
(13 mm)
OUTLETS
1/2" NPT
(13 mm)
3-3/8"
(86 mm)
OUTLETS
1/2" NPT
(13 mm)
1/2" (13 mm)
COPPER
THREADED INLETS
-1-
THREADED INLETS (STOPS)
M965724 (4/16)
1 INSTALL VALVE TRIM
• Figure 1. Remove plaster guard from valve. Push CAP (1)
over VALVE CARTRIDGE (2) until seated against stop.
1
PLASTER
GUARD
• Figure 2. Push ESCUTCHEON HOLDER (3) onto CAP (1)
and attach to valve body with LONG SCREWS (4). Mount
ESCUTCHEON SUPPORT (5) to ESCUTCHEON HOLDER
(3) with 4 SHORT SCREWS (6).
• Figure 3. Install ESCUTCHEON (7) onto CAP (1) and push
flush against finished wall. Escutcheon (7) will snap fit onto
ESCUTCHEON SUPPORT (5).
2
Figure 1.
1
4
5
7
3
5
1
Figure 3.
Figure 2.
6
2 INSTALL TRIM
CAUTION
3 INSTALL HANDLE
Protect finish on SHOWER HEAD
and TUB SPOUT when installing.
• Remove PIPE PLUG and CAP (1, 2) from shower pipe
and tub filler pipe.
• Hold ADAPTER (1) onto VALVE STEM (2) and install
ADAPTER SCREW (3) through ADAPTER (1) into
VALVE STEM (2).Tighten ADAPTER SCREW (3) to
secure ADAPTER (1) to VALVE STEM (2).
• Install SHOWER ESCUTCHEON (3) onto SHOWER ARM
(4). Apply sealant or Teflon tape to threads on both ends
of SHOWER ARM (4) and thread longer leg of SHOWER
ARM (4) into shower elbow.
• Install HANDLE BASE (4) onto ADAPTER (1). Insert
SET SCREW (5) into HANDLE BASE (4). Align
HANDLE BASE (4) and tighten with HEX WRENCH (6)
supplied.
Note: Apply sealant or Teflon Tape to shower arm.
• Thread SHOWER HEAD (5) onto SHOWER ARM (4).
Install TUB SPOUT (6). Tighten with HEX WRENCH
supplied. Important: Do not over tighten Set Screw.
3
O-RING
3
4
4
5
1
APPLY SEALANT OR
TEFLON TAPE TO THREADS
2
2
1
5
6
6
1-1/2"
HEX WRENCH
-2-
M965724 (4/16)
4 ADJUST HOT LIMIT STOP
2
311
97531
0
5
1
3
• Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before
making adjustment to HOT LIMIT STOP (1). Use a flat blade screwdriver
to pry free the HOT LIMIT SAFETY STOP (1). Pull forward and rotate
counterclockwise one number to limit hot water temperature.
Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT
STOP (1) for indication.
2
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
1
4
15
1
• By restricting HANDLE rotation and limiting the amount of hot water
allowed to mix with the cold, the HOT LIMIT SAFETY STOP (1)
reduces risk of accidental scalding. To set the maximum hot water
temperature of your faucet, all you need to do is adjust the setting on
the HOT LIMIT SAFETY STOP (1).
3
3
1
5
1
1
9
7
5
3
1
5 TO GAIN ACCESS TO VALVE FOR SERVICING
5
15
1
1
3
1
1
• Remove ESCUTCHEON and CARTRIDGE CAP (see step 1 and reverse).Shut off water supply by either closing off main water supply, or
closing off the hot and cold CHECK STOPS on valve.
1
9
7
5
3
4
• Remove HANDLE (see step 3 and reverse).
COLDER
(Larger Numbers)
0 1 3 5 7 9 11 13 15
VALVE LEAKS WHEN SHUT OFF
• Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4)
and pull out PRESSURE BALANCING (5) unit.
• Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6).
Remove CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8).
• Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws. Turn on water supply and see
above for installing TRIM and HANDLE.
UNABLE TO MAINTAIN CONSTANT TEMPERATURE
• Remove PRESSURE BALANCE UNIT (5).
• Remove CAPS (7) and clean valve thoroughly.
• Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth.
Order Repair Part M952100-0070A if balancing unit is defective.
• Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting.
Top flange should butt-up against top of casting.
BACK TO BACK INSTALLATION
• Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the large
outlet port faces down.
• Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should
butt up against top of casting.
• Reassemble FIXATION RING (4) and CARTRIDGE (1).
4
8
ROTATE 180˚
1
LARGE OUTLET
5
7
6
5
3
INLETS
9
2
BACK TO BACK INSTALLATION
6 CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
-3-
M965724 (4/16)
TOWNSEND®
BATH AND SHOWER
TRIM KIT
MODEL NUMBERS
T353.500
T353.501
T353.502
T353.507
T353.508
M970050-YYY0A
SHOWER ARM & FLANGE
A912654-0070A
O-RING
M953503-XXX250A
SHOWER HEAD
2.5 GPM
M953503-XXX240A
SHOWER HEAD
1.75 GPM
M907053-YYY0A
CARTRIDGE CAP
M961827-0070A
ESCUTCHEON HOLDER
A918477-0070A
HANDLE SCREW
M907837-YYY0A
ESCUTCHEON
M950421-YYY0A
DIVERTER SPOUT
(SLIP-ON)
M918039-0070A
HANDLE ADAPTER
M970051-YYY0A
HANDLE KIT
Replace the “YYY” with
appropriate finish code
POLISHED CHROME
002
STAINLESS STEEL
075
LEGACY BRONZE
278
POLISH NICKEL
013
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST
Saturday 10:00 a.m. to 4:00 p.m. EST
IN CANADA 1-800-387-0369
(TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
-4-
M965724 (4/16)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement