American Standard Townsend Single-Handle 1-Spray Tub and Shower Faucet installation Guide
Add to my manuals
4 Pages
advertisement
▼
Scroll to page 2
of 4
INSTALLATION INSTRUCTIONS T353.500 T353.501 T353.502 T353.507 T353.508 TOWNSEND® BATH AND SHOWER TRIM KIT Thank you for selecting American Standard... the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin. Certified to comply with ANSI A112.18.1M RECOMMENDED TOOLS Phillips Screwdriver Plumbers’ Putty or Caulking Adjustable Wrench Teflon Tape Channel Locks Flat Blade Screwdriver ROUGHING-IN DIMENSIONS • To assure proper positioning in relation to wall. Note roughing-in dimensions. SHR. 1/2" (13 mm) NOM. COPPER SWEAT FINISHED WALL INLETS 4-1/16" (103 mm) SWEAT INLETS 1-5/8" TO 3-1/4" (41 TO 83 mm) INLETS 1/2" (13 mm) NOM. COPPER SWEAT 2" (51 mm) 4-1/16" (103 mm) 1/2" (12 mm) NPT TUB 1/2" (13 mm) NOM. COPPER SWEAT 3.3/8" (85 mm) REF. 74" (1880 mm) FOR HEAD CLEARANCE 2-9/16" (65 mm) SWEAT INLETS (STOPS) 1-5/8" TO 3-1/4" (41 TO 83 mm) 5-7/8" (149 mm) SHR. 1/2" (13 mm) NOM. COPPER SWEAT OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN 65'' AND 80'' (1651 AND 2032 mm) 7" (177 mm) REF. 4-1/16" (103 mm) TUB 1/2" (13 mm) NOM. COPPER SWEAT INLETS 1/2" (13 mm) NOM. COPPER SWEAT 7-1/4" (184 mm) 18" (457 mm) OPTIONAL INLETS 1/2" NPT (13 mm) 3-3/8" (86 mm) 1-1/2" REF. (38 mm) 3-3/8" (86 mm) 6.5" REF. (165 mm) TOP OF TUB RIM BOTTOM OF TUB Product names listed herein are trademarks of AS America, Inc. © AS America, Inc. 2016 4" (102 mm) 5-7/8" (149 mm) INLETS 1/2" NPT (13 mm) OUTLETS 1/2" NPT (13 mm) 3-3/8" (86 mm) OUTLETS 1/2" NPT (13 mm) 1/2" (13 mm) COPPER THREADED INLETS -1- THREADED INLETS (STOPS) M965724 (4/16) 1 INSTALL VALVE TRIM • Figure 1. Remove plaster guard from valve. Push CAP (1) over VALVE CARTRIDGE (2) until seated against stop. 1 PLASTER GUARD • Figure 2. Push ESCUTCHEON HOLDER (3) onto CAP (1) and attach to valve body with LONG SCREWS (4). Mount ESCUTCHEON SUPPORT (5) to ESCUTCHEON HOLDER (3) with 4 SHORT SCREWS (6). • Figure 3. Install ESCUTCHEON (7) onto CAP (1) and push flush against finished wall. Escutcheon (7) will snap fit onto ESCUTCHEON SUPPORT (5). 2 Figure 1. 1 4 5 7 3 5 1 Figure 3. Figure 2. 6 2 INSTALL TRIM CAUTION 3 INSTALL HANDLE Protect finish on SHOWER HEAD and TUB SPOUT when installing. • Remove PIPE PLUG and CAP (1, 2) from shower pipe and tub filler pipe. • Hold ADAPTER (1) onto VALVE STEM (2) and install ADAPTER SCREW (3) through ADAPTER (1) into VALVE STEM (2).Tighten ADAPTER SCREW (3) to secure ADAPTER (1) to VALVE STEM (2). • Install SHOWER ESCUTCHEON (3) onto SHOWER ARM (4). Apply sealant or Teflon tape to threads on both ends of SHOWER ARM (4) and thread longer leg of SHOWER ARM (4) into shower elbow. • Install HANDLE BASE (4) onto ADAPTER (1). Insert SET SCREW (5) into HANDLE BASE (4). Align HANDLE BASE (4) and tighten with HEX WRENCH (6) supplied. Note: Apply sealant or Teflon Tape to shower arm. • Thread SHOWER HEAD (5) onto SHOWER ARM (4). Install TUB SPOUT (6). Tighten with HEX WRENCH supplied. Important: Do not over tighten Set Screw. 3 O-RING 3 4 4 5 1 APPLY SEALANT OR TEFLON TAPE TO THREADS 2 2 1 5 6 6 1-1/2" HEX WRENCH -2- M965724 (4/16) 4 ADJUST HOT LIMIT STOP 2 311 97531 0 5 1 3 • Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before making adjustment to HOT LIMIT STOP (1). Use a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1). Pull forward and rotate counterclockwise one number to limit hot water temperature. Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1) for indication. 2 HOTTER (Smaller Numbers) 0 1 3 5 7 9 11 13 15 1 4 15 1 • By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP (1) reduces risk of accidental scalding. To set the maximum hot water temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (1). 3 3 1 5 1 1 9 7 5 3 1 5 TO GAIN ACCESS TO VALVE FOR SERVICING 5 15 1 1 3 1 1 • Remove ESCUTCHEON and CARTRIDGE CAP (see step 1 and reverse).Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve. 1 9 7 5 3 4 • Remove HANDLE (see step 3 and reverse). COLDER (Larger Numbers) 0 1 3 5 7 9 11 13 15 VALVE LEAKS WHEN SHUT OFF • Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and pull out PRESSURE BALANCING (5) unit. • Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8). • Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws. Turn on water supply and see above for installing TRIM and HANDLE. UNABLE TO MAINTAIN CONSTANT TEMPERATURE • Remove PRESSURE BALANCE UNIT (5). • Remove CAPS (7) and clean valve thoroughly. • Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth. Order Repair Part M952100-0070A if balancing unit is defective. • Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting. Top flange should butt-up against top of casting. BACK TO BACK INSTALLATION • Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the large outlet port faces down. • Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should butt up against top of casting. • Reassemble FIXATION RING (4) and CARTRIDGE (1). 4 8 ROTATE 180˚ 1 LARGE OUTLET 5 7 6 5 3 INLETS 9 2 BACK TO BACK INSTALLATION 6 CARE INSTRUCTIONS: DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH. DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE. -3- M965724 (4/16) TOWNSEND® BATH AND SHOWER TRIM KIT MODEL NUMBERS T353.500 T353.501 T353.502 T353.507 T353.508 M970050-YYY0A SHOWER ARM & FLANGE A912654-0070A O-RING M953503-XXX250A SHOWER HEAD 2.5 GPM M953503-XXX240A SHOWER HEAD 1.75 GPM M907053-YYY0A CARTRIDGE CAP M961827-0070A ESCUTCHEON HOLDER A918477-0070A HANDLE SCREW M907837-YYY0A ESCUTCHEON M950421-YYY0A DIVERTER SPOUT (SLIP-ON) M918039-0070A HANDLE ADAPTER M970051-YYY0A HANDLE KIT Replace the “YYY” with appropriate finish code POLISHED CHROME 002 STAINLESS STEEL 075 LEGACY BRONZE 278 POLISH NICKEL 013 HOT LINE FOR HELP For toll-free information and answers to your questions, call: 1 (800) 442-1902 Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) Weekdays 8:00 a.m. to 7:00 p.m. EST IN MEXICO 01-800-839-1200 -4- M965724 (4/16)
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement