- Computers & electronics
- Audio & home theatre
- Soundbar speakers
- Seismic Audio
- MAGNITUDE2400
- User manual
Seismic Audio MAGNITUDE2400 Power Amplifier User Manual
Add to my manuals6 Pages
The Seismic Audio MAGNITUDE2400 is a professional power amplifier capable of delivering 2x 800W of power at 8 ohms in stereo mode and 2500W in bridged mode, making it suitable for a wide range of applications from small to medium-sized venues. It features XLR inputs and turn-lock speaker outputs, a clip indicator for each channel, protection circuitry against overheat, overload, short circuit, and DC, and a soft-start function. The input sensitivity can be selected between 0.8V and 1.
advertisement
▼
Scroll to page 2
of 6
SEISMIC AUDIO Professional Power Amplifier Professional Power Amplifier www.seismicaudiospeakers.com www.facebook.com/seismicaudio USER MANUAL Professional Audio Equipment PREFACE Thank you for your purchase of Professional Audio Equipment.Please read the manual carefully before you use the product, it will give you correct guidance,and it is useful for the equipments normal work and extending its life .All our products are promised one-year quality warranty.Provided any product found quality defect within one year,we will be responsible for repairing or replacing. The staff have always been trying to develop their professional audio equipment with high-tech , high performance and with competitive price.Up to now,we own 70 different models,covering high , secondly, and low three levels and are able to provide high quality equipments for different kinds of occasions. In addition to universal used product,we even own the most advanced remote control amplifiers and power link system. In the process of research and development,we have been trying to inpour high-tech soul to every product,and to create high quality equipments.We have been adopting “ISO Quality Guarantee System” to supervise every product whether it has conformed with strict and professional requirements, whether it has received perfect after - sales services. We do that only for one purpose:we hope our customers will really benefit from out high-tech, high - performance and competitive price products,as well as good after-sales services and technical backstopping .We are always doing out best to return our customers for their support to products , we make sure our customers feel they deserve purchasing professional audio equipment. IMPORTANT PRECAUTIONS . Read all documentation before operating your equipment.Retain all documentation for further reference. . Mains voltage must be correct and the same as that printed on the rear of the unit .Damage caused by connection to improper AC voltage is not covered by any warranty. . Always operate the unit with the AC ground wire connected to the electrical system ground .Precautions should be taken so that the means of grounding of a piece of equipment is not defected. . Connecting amplifier outputs to oscilloscopes or other test equipment while the amplifer is in bridged mode may damage both the amplifier and test equipment. . Do not drive the inputs with a signal level greater than that required to drive equipment to full output. . Do not run the output of any amplifier channel back into another channel's input. Do not parallel or series connect an amplifier output with any other amplifier output. 7. In system setup,amplifier's output power must be greater 50%-100% than the loaded loudspeaker s rated power. 8. Make sure the signal correctly connect to the amplifier s input channel at current input mode. 9. Please turn off the power switch,when pull off the power cord and signal cable or selectthe input mode switch. 10. In typical use, Please set the volume to 0dB position. | 11. Sometime, one signal to more than one amplifier, suggest use signal distributor. E OO NA O a Professional Audio Equipment A | RISK OF ELECTRIC SHOCK | /N DO E ATTENTION: RISQUE DE CHOC ELECTRIQUE - NEPAS OUVRIR WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE IMPORTANT : Use of controls or adjustments or performance of procedures other than those specified here in may result in hazardous radiation exposure. DESCRIPTION FRONT PANEL: … PROT CLIP Зав "78 +1048 -1548 -20d8 sic 1. Air Exit This part is the air exit. Don’t obstruct it. 2. "POWER " Indicator This indicator turns orange when amplifiers is stand by.The indicator turns green when you switch your amplifier on. 3. "CLIP " Indicator Any illumination of the clip indicates a state of over modulation (distortion at extremely high volumes). In this case, check the output signal of your mixer and turn down the input gain control. Please keep in mind that the power amplifier con not correct any distortion. 4. Channel 1 Volume Control In stereo mode, this potentiometer allows the adjustment of the channel 1 input level. (left channel). In Bridge mode, this potentiometer | allows the adjustment of the two channels at the same time. 5. "PROTECTION " Indicator When this indicator lights, that means the power amplifier is in the protection mode. Switch off the device and find out the problem. This power amplifier is protected overheat, overload, short circuit, DC, softstart. . "SIGNAL " Indicator The illumination of the LED only indicates a safe operation. . Handles Those handles are used for easy transportation. . Power Switch Use this switch to switch your power amplifier on. . Channel 2 Volume Control In stereo mode, this potentiometer allows the adjustment of the channel 2 input level. (Right channel) In bridge mode, this potentiometer is disabled. Professional Audio Equipment DESCRIPTION REAR PANEL: 10. 11. 12. 13. 14. 15. Channel 1 XLR Input This XLR inputis a balanced input. Connect this input to the left output of your mixer. Channel 1 Link Socket This balanced socket is used to link another amplifier. Input Sensitivity Selector This selector allows to choose the input sensitivity:either 0.8V or 1.6V. Operation Mode Selector This switch is used to choose the operating mode of the power amplifier: Mode stereo:2 inputs (channel 1 and 2) and 2 outputs are used. Mode parallel: 1 input ( channel 1) and 2 outputs are used. Mode bridge: 1 output are used. Channel 1 Turn Lock Output Connect this turn lock output to a speaker. The branching is +1, -1 ( exceptin bridge mode where the branching is +1, +2). input (channel 1) and 1 Channel 2 Turn Lock Output Connect this turn lock output to a speaker. The branching is+1, -1. 16. 17. 18. 19. 20. 21. AC Cord Plug this cord into the power supply socket. (Before using the power amplifier, check if the power supply is 110V). Air Entrance This part is the air entrance. Don’t obstruct it. Channel 2 Link Socket This balanced socket is used to link another amplifier. Channel 2 XLR Input This XLR inputis a balanced input. Connect this input to the right output of your mixer. Grounding Selector If you have humor noise in your speaker, put the selectior in " ON " position. Fuse The fuse is used to protect your amplifier from different kinds of AC problems. If the power amplifieris " on " and nothing lights, please verify the fuse compartment. If fuse is broken, please read it and change with a new one of same size and value. Professional Audio Equipment CONNECTING FOR: Stereo mode: In this mode, connect the 2 inputs CH1 and CH2 to your mixer's outputs. Put the selector on the stereo position. Output volume can be adjusted by means of the two potentiometers. Connect the 2 turn lock outputs to the 2 speakers. Parallel mode: + 1 og a lr. © — 1 In this mode, connect the input CH1 to your mixer’s outputs. Put the selector on the parallel position. Output volume can be adjusted by means of the two potentiometers. Connect the 2 turn lock outputs to the 2 speakers. Bridge mode: XLR In this mode, connect the input CH1 to your mixer’s outputs. Put the selector on the bridge position. Output volume can be adjusted with channel 1 potentiometer. Connect the channel 1 turn lock output to the speaker. y Professional Audio Equipment SAFETY INSTRUCTIONS: Read all safety instructions before operating amplifier. Install equipment as follows: -- Install in a flat place, not bending or curved. -- Do not install near water and moisture. -- Place power amplifier away from heat sources,such as radiators or other heat source. Keep in mind the following when connecting amplifiers -- Read the user manual before connecting the amplifier -- Connect each connection of the amplifier perfectly.If not,it may cause hum,damage, electric shock in case of disconnection. -- To prevent electric shocks,do not open top cover. Connect the power cord with safety after check fo AC power. SPECIFICATIONS: DC Magnitude2400 Magnitude3600 2x 800W 2x 1200W 2x 1260W 2x 1800W 2500W 3600W 5--50K+0.5dB < 0.05% @8 2 1/3Po — 102dB — 104dB 45V/u S SOV/u S >400 >65dB@8 2 1KHz 20K 2 (Balance )/1O0K 2 (Unbalance) 0.8V/1.6V Overheat short circuits, DC,limit and--softstart,Output relay-Zero Current Switch, Intellctual Clip limiter 2U 2U 575 Хх 570 X 158MM 650 x 585 X 158MM WARRANTY CONDITIONS All products are warranted for a period of one year from all manufacturers defects. The warranty begins when the product is sold to the end-user,and no more than 12 months after the production of the unit. The warranty is void if their are any signs of tampering of the unit, unless authorized by an agent of in writing. If by chance the unit were to be defective,at that point the client must pre-pay the shipment back to the warranty center withit’ s original package. The amplifiers have all protections but bad use can damaged the amplifier and is not covered by the warranty. The amplifier have some mechanical parts that if over used abusively is not covered by the Limited Warranty. For any further information or question regarding the amplifier please contact your distributor or place from which you purchased this product. a
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project