The Go Power! GP-IC2000-12-PKG is a powerful and versatile inverter/charger designed for mobile and home power applications. It combines the functions of a pure sine wave inverter, battery charger, and AC transfer switch in one unit, saving space, installation time, and system complexity. This unit is specifically designed for use with a 12-volt battery system and can provide reliable AC power for your RV, boat, or home.
advertisement
INVERTER/CHARGER
IC 2000 ™
User Manual
GP-IC-2000
© 2016 Go Power! By Carmanah Technologies
Worldwide Technical Support and Product Information gpelectric.com
Carmanah Technologies Corporate Headquarters
250 Bay St, Victoria, BC Canada V9A 3K5
Tel: 1.866.247.6527
79497_MAN_GP_IC_2000_Rev_A powered by
®
Congratulations on purchasing your Go Power! GP-IC-2000 Inverter / Charger. The GP-IC-2000 Inverter / Charger combines the functions of a pure sine wave inverter, battery charger and AC transfer switch into one unit - saving space, installation time and system complexity. The GP-IC-2000 is designed for mobile and home power applications.
• Pure Sine Wave Inverter Output - assures the AC output voltage is perfectly reliable even when limited external AC power is available
• 50-amp a leg AC pass through capability (Neutral rated to 50A)
• Multi-stage battery charging
• Inverter mounted ON/OFF switch with LED indicator
• Built in handles for easy installation
• BTS (Battery Temperature Sensor) provides automatic battery temperature compensation for optimum charging even during extreme temperature changes
Combined with the numerous DC power systems Go Power! manufactures and sells, the GP-IC-2000 allows you to enjoy the luxuries that electricity provides, with or without a campsite hookup. This manual will aid in the process of installing the Go Power!
GP-IC-2000 Inverter / Charger. Please read and understand this manual before installing the Go Power! GP-IC-2000 Inverter/
Charger. Please retain this manual for future reference.
Record the unit’s model and serial number below, it is much easier and quicker to record this information now at the pre - installation stage.
Model Number:
Serial Number:
Date of Install:
Battery Bank Information:
(size, install date, battery type)
CFB
Corrugated
Recycles www.corrugated.org
3
Product Packaging
Please safely store the packing the GP-IC-2000 was delivered in or please recycle the packaging components as outlined below;
Plastic foam protection
4 Corrugated fiberboard main box
7
LDPE
Low Density
Polyetheylene
CFB
3 4
Plastic accessories bag
7
2. GENERAL INFORMATION CFB
People. Planet. Profit.
Carmanah Technologies
3 4
CFB
3
7
4 7
Local recycling centres can be found here;
CFB
3 4 7 www.earth911.com/recycling-center-search-guides
www.earth911.com/recycling-center-search-guides
1. CONTENTS
2. GENERAL INFORMATION ....................................................................................................... 4
2.1 CAUTIONS.....................................................................................................................................................4
2.2 DISCLAIMERS ...............................................................................................................................................7
2.3 GP-IC-2000 KIT PARTS .................................................................................................................................7
2.3.1 PARTS CHECKLIST ........................................................................................................................7
2.4 UNIT FEATURES ...........................................................................................................................................8
2.5 UNIT DIMENSIONS .....................................................................................................................................10
2.6 UNIT ACCESSORIES ..................................................................................................................................11
2.7 INSTALLATION TOOLS AND MATERIALS .................................................................................................11
3. INSTALLATION ........................................................................................................................11
3.1 TYPICAL INVERTER / CHARGER SYSTEM OVERVIEW ......................................................................... 12
3.2 LOCATION AND ENVIRONMENTAL REQUIREMENTS ........................................................................... 16
3.3 MOUNTING THE INVERTER / CHARGER ................................................................................................ 17
3.4 GENERAL WIRING SPECIFICATIONS ...................................................................................................... 18
3.5 DC WIRING................................................................................................................................................. 19
3.5.1 DC WIRE SIZING.......................................................................................................................... 20
3.5.2 DC OVERCURRENT PROTECTION AND DC DISCONNECT .................................................... 20
3.5.3 PREPARING THE DC CABLES .................................................................................................... 20
3.5.4 DC CABLE CONNECTIONS ........................................................................................................ 20
3.5.5 BATTERY TEMPERATURE SENSOR .......................................................................................... 21
3.5.6 WIRING THE INVERTER / CHARGER TO THE BATTERY BANK .............................................. 22
3.5.7 BATTERY LAYOUTS .................................................................................................................... 23
3.5.8 DC GROUNDING.......................................................................................................................... 24
3.6 AC WIRING ................................................................................................................................................. 25
3.6.1 AC POWER SOURCES ................................................................................................................ 26
3.6.2 AC WIRE SIZE AND OVERCURRENT PROTECTION ................................................................ 26
3.6.3 GFCI (GROUND FAULT CIRCUIT INTERRUPTION) OUTLETS ................................................. 26
3.6.4 AC TERMINAL BLOCK CONNECTIONS ..................................................................................... 27
3.6.5 AC CABLE CONNECTIONS ......................................................................................................... 28
3.6.6 AC WIRING 1 - Single Phase, ≤30A Service, Single IN / Single OUT .......................................... 30
3.6.7 AC WIRING 2 - Single Phase, 30A> Service, Single IN / Single OUT ......................................... 31
3.6.8 AC WIRING 3 - Split Phase, 50A Service, Dual IN, Dual OUT, Option 1 ...................................... 32
3.6.9 AC WIRING 4 - Split Phase, 50A Service, Dual IN, Dual OUT, Option 2 ...................................... 33
3.6.10 GROUNDING THE INVERTER - AC GROUNDING ..................................................................... 34
3.6.11 DISABLING THE NEUTRAL TO CHASSIS GROUND CONNECTION ........................................ 35
3.6.12 GROUNDING ON BOATS ............................................................................................................ 36
3.7 FINAL INSPECTION ................................................................................................................................... 37
3.8 TESTING THE INSTALLATION .................................................................................................................. 37
3.9 WARNING LABELS .................................................................................................................................... 37
4. OPERATION ........................................................................................................................... 38
4.1 GENERAL OPERATING NOTES .................................................................................................................38
4.2 AC POWER PASS THROUGH MODE ........................................................................................................40
4.3 CHARGING MODE ......................................................................................................................................41
4.4 POWER SHARING MODE ..........................................................................................................................42
4.5 GENERATOR MODE ...................................................................................................................................43
4.6 INVERTING MODE ......................................................................................................................................44
4.7 BATTERY TEMPERATURE SENSOR OPERATION ...................................................................................45
4.8 FACTORY DEFAULT VALUES ....................................................................................................................45
4.9 GP-IC-2000 FAULT CONDITIONS ..............................................................................................................46
4.10 MAINTENANCE AND TROUBLESHOOTING .............................................................................................46
5. SPECIFICATIONS .................................................................................................................. 48
6. WARRANTY RETURN PROCEDURE ................................................................................... 49
7. PRODUCT END OF LIFE INFORMATION - RECYCLING ..................................................... 50 gpelectric.com | [page 3]
Note
2.GENERAL INFORMATION
2.1 CAUTIONS / WARNINGS
This document contains important safety instructions for the products produced by Carmanah Technologies. Read all instructions and cautionary markings on the product and on any accessories or additional equipment included in the installation. Failure to follow these instructions could result in severe shock or possible electrocution. Use extreme caution at all times to prevent accidents.
All electrical work must be performed in accordance with local and national electrical codes. These instructions are for use by qualified personnel who meet all local and governmental code requirements for licensing and training for the installation of electrical power systems with AC and DC voltage up to 600 volts.
Installation, maintenance, and connection of inverters must be performed by qualified personnel, in compliance with local electrical standards, wiring rules, and the requirements of local power authorities and/or companies.
Safety regulations relevant to the location shall be followed during installation, operation and maintenance. Improper operation may have a risk of electric shock or damage to equipment and property.
i
General Safety
WARNING!
Hazard to Human Life
WARNING!
Shock Hazard
WARNING!
Burn / Fire Hazard
CAUTION!
Hazard to Equipment
IMPORTANT
This type of notation indicates that the hazard could be harmful to human life.
Danger of Shock or electrocution.
Danger of hot surface and/or fire.
This type of notation indicates that the hazard may cause damage to the equipment.
This type of notation indicates that the information provided is important to the installation, operation and/or maintenance of the equipment. Failure to follow the recommendations in such a notation could result in annulment of the equipment warranty.
i
WARNING!
Limitations on Use
CAUTION!
Equipment Damage
IMPORTANT
This equipment is NOT intended for use with life support equipment or other medical equipment or devices.
This product is designed for indoor/compartment installation. It must not be exposed to any liquids, moisture of any type.
Only use components or accessories recommended or sold by
Carmanah Technologies or its authorized agents.
Do not attempt to install this equipment if it appears to be damaged in any way. See the Warranty section for instructions on returning the equipment.
[page 4] | gpelectric.com
GENERAL INFORMATION
Personal Safety
Equipment Safety
WARNING!
Personal Injury
Use safe lifting techniques when lifting this equipment as recommended by the Occupational Safety and Health Association
(OSHA) or other local codes.
Use standard safety equipment when working on this equipment, such as safety glasses, ear protection, steel-toed safety boots, safety hard hats, etc.
Use standard safety practices when working with electrical equipment. (Remove all jewelry, use insulated tools, wear cotton clothing, etc.)
Never work alone when installing or servicing this equipment. Have someone nearby that can assist if necessary.
Do not touch the Inverter / Charger during operation. The temperature of some parts of the inverter may exceed 60° during operation. Let it cool for at least 5 minutes after shutdown before touching it.
Ensure that children, pets, and other animals are kept away from the inverter, solar arrays, battery bank, and utility grid components.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
WARNING!
Lethal Voltage
WARNING!
Fire Hazard
Review the system configuration to identify all possible sources of energy. Ensure ALL sources of power are disconnected before performing any installation or maintenance on this equipment.
Confirm that the terminals are de-energized using a validated voltmeter (rated for a minimum 1000 VAC and 1000 VDC) to verify the de energized condition.
Do not perform any servicing other than that specified in the installation instructions unless qualified to do so, or have been instructed to do so by Carmanah Technologies Technical Support personnel.
To avoid electric shock, disconnect the DC input and AC input of the inverter at least 5 minutes before performing any installation or maintenance.
Do not tighten the AC and DC terminals or pull on the AC and DC wiring when the inverter is running.
Do not keep combustible or flammable materials in the same room with the equipment. Some products contain relays with moving parts and are not ignition-protected.
Ensure AC, DC, and ground cable sizes conform to local codes.
See product manuals for minimum size requirements.
Ensure all conductors are in good condition.
Do not operate the unit with damaged or substandard cabling.
gpelectric.com | [page 5]
GENERAL INFORMATION
CAUTION!
Equipment Damage
CAUTION!
Equipment Damage
When connecting cables from the inverter to the battery terminals, ensure the proper polarity is observed. Connecting the cables incorrectly can damage or destroy the equipment and the warranty may be annulled.
Thoroughly inspect the equipment prior to energizing. Verify that no tools or equipment have been inadvertently left behind.
Ensure clearance requirements are strictly enforced.
Keep all vents clear of obstructions that can prevent proper air flow around, or through, the unit.
Static electricity may damage electronic components. Take appropriate steps to prevent such damage to the inverter; otherwise the warranty may be annulled.
Battery Safety
i
WARNING!
Explosion, Electrocution, or
Fire Hazard
IMPORTANT
Ensure the cables (conductors) are properly sized.
Ensure clearance requirements are strictly enforced around the batteries.
Ensure the area around the batteries is well ventilated and clean of debris.
Never smoke, or allow a spark or flame near, the batteries.
Always use insulated tools. Avoid dropping tools onto batteries or other electrical parts.
Never charge a frozen battery.
Never use old or untested batteries. Check each battery’s label for age, type, and date code to ensure all batteries are identical.
If a battery must be removed, always remove the grounded terminal from the battery first. Make sure all devices are de-energized or disconnected to avoid causing a spark.
Use the battery types recommended by Carmanah Technologies.
Follow the battery manufacturer’s recommendations for installation and maintenance.
Insulate batteries as appropriate against freezing temperatures. A discharged battery will freeze more easily than a charged one.
If a remote or automatic generator control system is used, disable the starting circuit and/or disconnect the generator from its starting battery while performing maintenance to prevent accidental starting.
Wear complete eye and clothing protection when working with batteries. Avoid touching bare skin or eyes while working near batteries.
Keep plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes.
If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters the eye, immediately flood it with running cold water for at least 20 minutes and get medical attention as soon as possible.
[page 6] | gpelectric.com
GENERAL INFORMATION
2.2 DISCLAIMERS
IMPORTANT: Please follow installation and wiring instructions exactly as outlined to ensure safety. We recommend installation by an RV technician or professional electrician to ensure adherence to relevant electrical codes. We have made every reasonable effort to ensure the accuracy of the instructions in this manual, but Carmanah does not guarantee that the information is error free, nor do we make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. The specifications in this manual are for reference purposes only and are subject to change without notice. For additional information please see www.gpelectric.com.
DISCLAIMER: Carmanah disclaims liability for any direct, indirect or incidental damages caused by, or in case of, installation not performed following the instructions and cautions in this manual. Carmanah will refuse requests for exchanges or returns, resulting from the purchase and installation of items which do not comply with local codes. To avoid such concerns Carmanah recommends installation by a professional electrician or RV technician. Examples that are shown within this manual are for illustrative purposes only.
2.3 GP-IC-2000 KIT PARTS
Note Please unpack and make sure all parts shown in the list below are included in the kit. If any parts are missing please contact Carmanah’s customer service team at [email protected] or 1.866.247.6527.
2.3.1 PARTS CHECKLIST
ITEM # DESCRIPTION
01 GP-IC-2000 Inverter/Charger
02 Battery Temperature Sensor
03
04
DC Terminal Covers (Black and Red)
Phillips screw
05
06
07
M8 x 1.25 Nut, Split Washer, Flat Washer (installed on DC Terminals) 2
Ring Lugs 2
Spanish Warning Label (not shown below) 1
2
8
1
1
2
6
4 3 5 1 gpelectric.com | [page 7]
®
Temperature Sensor
4.9” (124mm)
.28” (7mm)
13.6” (346mm)
2” (51mm) 4.9” (124mm)
.51” (13mm)
GENERAL INFORMATION
2.4 UNIT FEATURES
12
Dip
Switches
11
Power
ON/OFF Switch
10
Inverter/Charger
Mode
9
Status LED
AC INPUT
REMOTE
ON/OFF
STATUS
POS +
AC Entry / Exit
Terminals
DC Ground
Terminal
1
2
NEG
-
INV. AC
OUTPUT
3
Remote Control
Port
4
Battery Sensor
Port
10
11
8
9
5
6
7
1
2
3
4
AC Entry/Exit Ports - Two 1-3/8” knockouts provided to accommodate up to 1-1/4” 50 amp RV Cable. Strain relief clamps provided to secure the AC input and output wires.
DC Ground Terminal - Use this connection to ground the exposed chassis of the inverter to the DC grounding system.
This terminal accepts CU/AL conductors from #14 to #2 AWG (2.1 to 33.6mm2).
Remote Control Port - Use this port to connect the optional remote control unit to the Inverter / Charger.
Battery Temperature Sensor Port - Use this port to connect the battery temperature sensor to the Inverter / Charger.
Mounting Flange - Use this to secure the Inverter/Charger to the mounting surface.
Negative (-) DC Terminal - Use this connection point to secure the battery bank negative (-) cable to the Inverter/Charger.
Always ensure the DC terminal cover is used to protect this terminal.
Positive (+) DC Terminal - Use this connection point to secure the battery bank positive (+) cable to the Inverter/Charger.
Always ensure the DC terminal cover is used to protect this terminal.
Intake Air Vents - These cut-outs are used as ventilation openings. Air is drawn in through the front of the Inverter/Charger and passes through to keep the electronics cool for optimum performance.
Status LED - Green, Red Blink, Red Fast Blink, Orange Solid, Orange Blink & Orange Fast Blink Status. See page 38 for further explanation.
Inverter/Charger LED - Inverter Mode = Solid Green.
Charging Mode = Green Blink
Power ON/OFF Switch - This push button switch can be used to turn the unit on/off. Warning! Power OFF does not disconnect the batteries or AC Power Source. Therefore the “AC output load is still active.
[page 8] | gpelectric.com
8
7
6
5
Intake Air
Vents (and on right side)
Positive (+)
DC Terminal
Negative (-)
DC Terminal
Mounting
Flange
13.7”
14.9”
(349mm)
(378mm)
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
12.6”
(321mm)
AC INPUT
REMOTE
ON/OFF
STATUS
INV. AC
OUTPUT
NEG
-
POS +
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
- PROTECTED EQUIPMENT IS REQUIRED.
DANGER:
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
AVERTISSEMENT:
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
WARNING:
CONTENANT CHACUNE 6 ou 12 CELLULES.
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
MISE EN GARDE:
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
CAUTION:
REMOTE
®
Temperature Sensor
AC INPUT
REMOTE
BATTERY
TEMP
ON/OFF
INV. / CHR.
MODE
STATUS
INV. AC
OUTPUT
NEG
-
POS +
AC INPUT
REMOTE
BATTERY
TEMP
ON/OFF
INV. / CHR.
MODE
STATUS
INV. AC
OUTPUT
NEG
-
POS +
4.9” (124mm)
.28” (7mm)
13.6” (346mm)
2” (51mm) 4.9” (124mm)
.51” (13mm)
12.6”
(321mm)
GENERAL INFORMATION
13.7”
14.9”
(349mm)
(378mm)
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
8.1”
(205mm)
Intake Air
Vents (and on right side)
Positive (+)
DC Terminal
Negative (-)
DC Terminal
Mounting
Flange
17
Built-in
Handles
13
Exhaust Air Vents
(Back side)
14
Serial Number
Label
15
AC Input Circuit
Breakers
16 AC Access Cover
15
16
17
12
13
14
Dip Switches - Reserved for future use.
Exhaust Air Vents - These cut-outs are used as ventilation openings. Air is drawn in through the front of the Inverter/
Charger and passes through to keep the electronics cool for optimum performance.
Serial Number Label - This label displays the unit serial number, date of manufacture and Inverter / Charger specifications.
AC Input Circuit Breaker - CB1 & CB2 - These circuit breakers protect the unit’s internal charger wiring and pass-thru relay when in AC pass through mode. Press in to reset. The input circuit breakers are not branch-rated.
AC Access Cover - Remove this panel to get access to the internal wiring terminal block. This terminal block is used to hardwire all inverter AC input and output wiring connections.
Built-In Handles - Use these handles to safely move the Inverter / Charger.
WARNING: Turning the unit OFF does not disconnect the batteries or AC power source. Therefore the “AC output load” is still active.
CAUTION: This Inverter does not include any output circuit breakers. So 20A branch-rated circuit breakers must be installed in the inverters output wiring (breaker panel).
CAUTION: The Inverter’s internal transfer AC transfer relay is rated for 50 amps a leg. The pass-thru current must be no greater than 50 amps a leg or damage to the relays and/or the input circuit breakers may occur.
gpelectric.com | [page 9]
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
- PROTECTED EQUIPMENT IS REQUIRED.
DANGER:
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
AVERTISSEMENT:
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
WARNING:
CONTENANT CHACUNE 6 ou 12 CELLULES.
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
MISE EN GARDE:
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
CAUTION:
REMOTE
®
Temperature Sensor
AC INPUT
REMOTE
BATTERY
TEMP
ON/OFF
INV. / CHR.
MODE
STATUS
INV. AC
OUTPUT
NEG
-
POS +
GENERAL INFORMATION
2.5 UNIT DIMENSIONS
4.9” (124mm)
.28” (7mm)
13.6” (346mm)
2” (51mm) 4.9” (124mm)
.51” (13mm)
12”
(304mm)
12.6”
(321mm)
13.7”
14.9”
(349mm)
(378mm)
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
8.1”
(205mm)
[page 10] | gpelectric.com
CB2
50A
CB1
50A
REMOTE
AC INPUT
REMOTE
BATTERY
TEMP
ON/OFF
INV. / CHR.
MODE
STATUS
INV. AC
OUTPUT
NEG -
POS +
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
- PROTECTED EQUIPMENT IS REQUIRED.
DANGER:
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
AVERTISSEMENT:
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
WARNING:
CONTENANT CHACUNE 6 ou 12 CELLULES.
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
MISE EN GARDE:
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
CAUTION:
INPUT
50A
INPUT
50A
50A
CB2
50A
CB1
GENERAL INFORMATION
2.6 UNIT ACCESSORIES
The IC 2000 Inverter/Charger has two accessories available:
• IC 2000 series remote (not included).
• Battery temperature sensor (BTS) (included).
IC 2000 Remote
This remote control device can be used for monitoring the performance of the unit. It is also used to program certain settings on the Inverter, Charger and AC pass through.
Battery Temperature Sensor (BTS)
This sensor monitors the temperature of the battery bank. The temperature data is used to provide optimum battery charging even during extreme temperature changes.
INVERTER
ON/OFF
CHARGER
ON/OFF
Temperature Sensor
ENTER / SET BACK
®
SHORE POWER
UNIT READINGS
UNIT SETUP
REMOTE SETTINGS
2.7 REQUIRED TOOLS AND MATERIALS
Required Tools a. 13mm or adjustable wrench b. Screwdriver (Phillips & Flathead) c. Wire strippers and cutters d. Electric hand drill and drill bits
Optional Tools e. Keyhole saw f. Pencil or marker g. Pliers h. Caulking gun i. Sealant j. Digital multimeter k. Torque driver l. Butt splice crimping tool
Materials a. Conduit b. Strain-reliefs c. Electrical tape (Black, Red, Green, Blue, Brown, White) d. Zip-ties e. Mounting hardware gpelectric.com | [page 11]
AC INPUT
REMOTE
ON/OFF
STATUS
INV. AC
OUTPUT
NEG
-
POS
+
4.9” (124mm)
.28” (7mm)
13.6” (346mm)
2” (51mm) 4.9” (124mm)
.51” (13mm)
13.7”
14.9” (378mm)
(349mm)
CAUTION:
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
WARNING:
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
CB2
50A
CB1
50A
REMOTE
AC INPUT
REMOTE
ON/OFF
STATUS
INV. AC
OUTPUT
NEG
-
POS +
CAUTION:
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
MISE EN GARDE:
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
- PROTECTED EQUIPMENT IS REQUIRED.
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
- PROTECTED EQUIPMENT IS REQUIRED.
DANGER:
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
AVERTISSEMENT:
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
WARNING:
CONTENANT CHACUNE 6 ou 12 CELLULES.
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
MISE EN GARDE:
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
CAUTION:
3. INSTALLATION
3.1 TYPICAL SYSTEM OVERVIEW
The following diagrams on pages 12-15 show how the GP-IC-2000 is typically installed in a mobile RV application. The diagrams show where the Inverter/Charger is installed and how the mobile power system can be integrated with a Go Power! RV Solar Kit
(sold separately by Go Power, please contact us direct.)
Solar Panels
Refrigerator
Vent Cover
Internal
View
TYPICAL RV INSTALLATION
[page 12] | gpelectric.com
RV
Co nso
Are a le
GP-IC-Remote Solar
Controller
Cable to
Battery Bank
Cable to
GP-IC-2000 Unit
AC Power OUTPUT
- to RV appliances
AC Power INPUT
- from Shore Power / Generator
(Fuses / Breakers not shown)
Cables From
Solar Charge Controller Battery Bank
GP-IC-2000
Inverter / Charger
Cables to / from
Battery Bank
100W or 160W
Solar Panel
100W or 160W
Solar Panel
Refrigerator
Vent Cover
Cable to
Inverter
Solar
Controller
Fuse
Block
Fuse
Block
Battery Bank
AC
Loads
Inverter
Remote
Inverter
AC
Panel
Transfer
Switch
Fuse
Block
Converter /
Charger
Shore Power
/ Generator
Legend
MC4 Connector
30 Amp
Breaker
For this system we recommend a minimum of
6 batteries / 600 Amp Hour
Battery Bank
10 Ft Extension Cable
10AWG (Included)
25 Ft Cable
10AWG (Included)
Remote
Mate 2
FM
80
Refrigerator
Vent Cover
Solar Panels
Internal
View
INSTALLATION
RV
Co
Are a nso le
GP-IC-Remote Solar
Controller
Cable to
Battery Bank
Cable to
GP-IC-2000 Unit
AC Power OUTPUT
- to RV appliances
AC Power INPUT
- from Shore Power / Generator
(Fuses / Breakers not shown)
Cables From
Solar Charge Controller Battery Bank
GP-IC-2000
Inverter / Charger
Cables to / from
Battery Bank gpelectric.com | [page 13]
100W or 160W
Solar Panel
100W or 160W
Solar Panel
Refrigerator
Vent Cover
Cable to
Inverter
Solar
Controller
Fuse
Block
Fuse
Block
Battery Bank
AC
Loads
Inverter
Remote
Inverter
AC
Panel
Transfer
Switch
Fuse
Block
Converter /
Charger
Shore Power
/ Generator
Legend
MC4 Connector
30 Amp
Breaker
For this system we recommend a minimum of
6 batteries / 600 Amp Hour
Battery Bank
10 Ft Extension Cable
10AWG (Included)
25 Ft Cable
10AWG (Included)
Remote
Mate 2
FM
80
INSTALLATION
Shore Power
120/240 VAC
Generator Power
120/240 VAC
Solar Panel Solar Panel
AC Transfer Switch
Refrigerator
Vent Cover or
Cable Entry Plate
Solar Charge
Controller
Fuse
Typical RV Solar Kit
(sold separately by Go Power)
To Battery
Bank
To Battery
Bank
Earth Ground (RV, Boat Ground)
Battery Temperature Sensor
Main Panel
[page 14] | gpelectric.com
ON
OFF
Remote Control (Optional)
120 VAC
240 VAC
(cabin install)
120 VAC
Sub Panel
GP-IC-2000
DC Panel
Battery Disconnect Switch
(not required if circuit breaker is used)
Fuse or Circuit Breaker
Battery Bank
Shore Power
120/240 VAC
Generator Power
120/240 VAC
Solar Panel Solar Panel
AC Transfer Switch
Refrigerator
Vent Cover or
Cable Entry Plate
Solar Charge
Controller
Fuse
Typical RV Solar Kit
(sold separately by Go Power)
To Battery
Bank
To Battery
Bank
Earth Ground (RV, Boat Ground)
Battery Temperature Sensor
Main Panel
INSTALLATION
ON
OFF
Remote Control (Optional)
120 VAC
240 VAC
(cabin install)
120 VAC
Sub Panel
GP-IC-2000
DC Panel
Battery Disconnect Switch
(not required if circuit breaker is used)
Fuse or Circuit Breaker
Battery Bank gpelectric.com | [page 15]
INSTALLATION
3.2 LOCATION AND ENVIRONMENTAL REQUIREMENTS
The GP-IC-2000 Inverter Charger must be installed in a location that meets the following requirements.
1. TEMPERATURE
Make sure the GP-IC-2000 is installed in a location where the normal air temperature is between 0 °C and 50 °C. The cooler the better within this range. Note the GP-IC-2000 maximum output wattage will derate in temperatures above 45 °C.
2. MOISTURE
Do not allow water or other fluids to come into contact with the GP-IC-2000. Do not expose to rain, snow or water.
CAUTION! Equipment Damage.
Installing the GP-IC-2000 in environments where moisture may occur will cause the Inverter/Charger to be exposed to the harmful effects of corrosive environments and certain components service lifes’ will be compromised and not covered by the warranty.
3. VENTILATION
For optimum Inverter/Charger performance the GP-IC-2000 must be installed so the front, side and rear air vents are not blocked or obstructed in any way. Do not install the GP-IC-2000 in an area with limited air flow. Allow as much space around the Inverter
/ Charger as possible, leaving at least 6” of airspace clearance around all ventilation areas.
CAUTION! Equipment Damage.
Do not mount the GP-IC-2000 in a zero clearance compartment. Do not cover the ventilation openings. Overheating and mechanical failure may occur.
4. FIRE
Install the GP-IC-2000 away from the battery bank, away from any flammable or combustible material (paper, flammable liquids, gasoline, cloths) that may be ignited by heat, sparks or flames. Never place the Inverter/Charger directly above the battery bank
- gases from the batteries will corrode and damage the Inverter/Charger, never allow battery acid to drip onto the unit.
5. ACCESSIBILITY / ORIENTATION
Do not block access to the GP-IC-2000 remote control and battery temperature access ports, status LEDs and the On/Off switch.
Allow enough room to access the AC and DC wiring terminals and connections as they will need to be checked and tightened periodically. The GP-IC-2000 must be installed in one of the approved mounting orientations detailed on page 17.
6. CLEAN
The GP-IC-2000 should be installed in a location which is clean and limits the introduction of dust, fumes, insects or rodents which could enter and block the Inverter/Chargers ventilation openings.
7. PROXIMITY TO BATTERY BANK
The GP-IC-2000 should be located as close to the batteries as possible but not within the same compartment. The length and size of the DC Cables will affect performance. Long DC wires tend to lose efficiency and reduce the overall performance of the
Inverter/Charger. Use the DC cables recommended on page 20.
[page 16] | gpelectric.com
Temperature Sensor
Temperature Sensor
AC INPUT
REMOTE
REMOTE
ON/OFF
STATUS
ON/OFF
INV. / CHR.
MODE
STATUS
AC INPUT
INV. AC
OUTPUT
NEG -
POS +
NEG -
POS +
REMOTE
AC INPUT
AC INPUT
ON/OFF
REMOTE
BATTERY
TEMP
INV. AC
OUTPUT
STATUS
ON/OFF
INV. / CHR.
MODE
STATUS
INV. AC
OUTPUT
NEG
NEG -
-
POS
POS +
+
4.9” (124mm)
.28” (7mm)
4.9” (124mm)
.28” (7mm)
13.6” (346mm)
2” (51mm)
13.6” (346mm)
2” (51mm)
4.9” (124mm)
.51” (13mm)
4.9” (124mm)
.51” (13mm)
REMOTE
REMOTE
12.6”
(321mm)
13.7”
14.9” (378mm)
(349mm)
13.7”
14.9” (378mm)
(349mm)
CAUTION:
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
MISE EN GARDE:
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
DANGER:
- PROTECTED EQUIPMENT IS REQUIRED.
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
INSTALLATION
3.3 MOUNTING THE INVERTER/CHARGER
Before connecting any wires to the Inverter / Charger the unit must be mounted securely in a location which meets the requirements detailed in section 3.2.
The GP-IC-2000 weighs: 39 lbs (17.6Kg). Take the necessary precautions required whilst lifting, moving and installing the unit. It is recommended to use two people whilst mounting the unit. All mounting surfaces and hardware must be capable of supporting at least twice the weight of the Inverter / Charger.
The Inverter/Charger base can reach high temperatures and should be mounted on a noncombustible surface.
The GP-IC-2000 must be mounted in the positions highlighted below to meet regulatory requirements.
After determining the mounting position use the dimensions on page 10 or use the base of the Inverter / Charger to mark the mounting screw locations. Mount the unit with the appropriate mounting hardware (not supplied). Ensure the unit is fastened securely.
CAUTION:
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
MISE EN GARDE:
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
CAUTION:
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
AVERTISSEMENT:
MISE EN GARDE:
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
DANGER:
WARNING:
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
AVERTISSEMENT:
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
- PROTECTED EQUIPMENT IS REQUIRED.
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
INPUT
CB1
50A
INPUT
CB2
50A
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
- PROTECTED EQUIPMENT IS REQUIRED.
DANGER:
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
AVERTISSEMENT:
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
WARNING:
- PROTECTED EQUIPMENT IS REQUIRED.
DANGER: PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
MISE EN GARDE:
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
AVERTISSEMENT:
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
CAUTION:
50A
WARNING:
CB1
CONTENANT CHACUNE 6 ou 12 CELLULES.
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
50A
INPUT
CB2
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
MISE EN GARDE:
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
CAUTION:
CAUTION:
COMPA
VICEABLE PA SER
RY POLARIT ELECTRIC SHOCK, DO NOT EXPOSE
. • PROVIDED WITH INTEGRAL PROTECTION RESULT
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN
MISE EN GARDE:
TIMENT SANS
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIEN
D’ÊTRE RÉPARÉE
TATION RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS
DE LA POLARITÉ DES PILES DOI
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. •
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
O PRODUCE ARCS OR S TEND T
TMENTS CONTAINING B EXPLOSION, DO NOT INS
OF ELECTRIC SHOCK. USE ONLY
BREAKER SPECIFIED IN THE INS
O OPERATE PROPER TYPES MAY
TIMENT
HEATSINKS
AVERTISSEMENT:
- PROTECTED EQUIPMENT IS REQUIRED.
• CET ÉQUIPEMEN
O REDUCE THE RISK OF EXPLOSION - DO NO
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INS
DANGER:
DANS UN COMPA
ANT DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEP
TESTER AV
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUE
PRODUIT. LES HORIZONTAL MOUNT, BASE DOWN
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INS
MACHINE OU UNE ZONE CONTENANT UN
TATION
RY POLARIT
TIMENT
TIMENT SANS
O PRODUCE ARCS OR S
TMENTS CONTAINING B
TEND T
. • PROVIDED WITH INTEGRAL PROTECTION
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIEN
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS
ELECTRIC SHOCK, DO NOT EXPOSE
MISE EN GARDE:
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. •
CAUTION:
OF ELECTRIC SHOCK. USE ONLY
O OPERATE PROPER
BREAKER SPECIFIED IN THE INS
D’ÊTRE RÉPARÉE
CONTENANT CHACUNE 6 ou 12 CELLULES.
DE LA POLARITÉ DES PILES DOI
WARNING:
EXPLOSION, DO NOT INS
TYPES MAY
• CET ÉQUIPEMEN
AVERTISSEMENT:
HEATSINKS
DANS UN COMPA
ANT DE TESTER AV
PRODUIT. LES
DANGER:
O REDUCE THE RISK OF EXPLOSION - DO NO
- PROTECTED EQUIPMENT IS REQUIRED.
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUE
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INS
VICEABLE PA SER
COMPA
RESULT
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN
MACHINE OU UNE ZONE CONTENANT UN
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEP
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INS
HORIZONTAL MOUNT, BASE UP
+
POS
NEG
OUTPUT
INV. AC
MODE
STATUS
INV. / CHR.
ON/OFF
TEMP
BATTERY
REMOTE
AC INPUT
TEMP
BATTERY
REMOTE
INPUT
CB1
50A
INPUT
CB2
50A
WALL MOUNT, DC TERMINALS RIGHT
12.6”
(321mm)
8.1”
(205mm)
TATION
RY POLARIT
TIMENT
TIMENT SANS
O PRODUCE ARCS OR S
TMENTS CONTAINING B
TEND T
. • PROVIDED WITH INTEGRAL PROTECTION
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIEN
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS
ELECTRIC SHOCK, DO NOT EXPOSE
MISE EN GARDE:
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. •
CAUTION:
OF ELECTRIC SHOCK. USE ONLY
O OPERATE PROPER
BREAKER SPECIFIED IN THE INS
D’ÊTRE RÉPARÉE
CONTENANT CHACUNE 6 ou 12 CELLULES.
DE LA POLARITÉ DES PILES DOI
WARNING:
EXPLOSION, DO NOT INS
ANT DE TESTER AV
PRODUIT. LES
DANGER:
TYPES MAY
• CET ÉQUIPEMEN AVERTISSEMENT:
HEATSINKS
DANS UN COMPA
O REDUCE THE RISK OF EXPLOSION - DO NO
- PROTECTED EQUIPMENT IS REQUIRED.
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUE
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INS
VICEABLE PA SER
COMPA
RESULT
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN
MACHINE OU UNE ZONE CONTENANT UN
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEP
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INS
(378mm) 14.9”
(349mm) 13.7”
(13mm)
(124mm)
.51”
4.9”
(346mm) 13.6”
2” (51mm)
(7mm)
(124mm)
.28”
4.9”
12”
(304mm) gpelectric.com | [page 17]
+ POS
NEG
OUTPUT
INV. AC
MODE
STATUS
INV. / CHR.
ON/OFF
TEMP
BATTERY
REMOTE
AC INPUT
Temperature Sensor
INSTALLATION
3.4 GENERAL WIRING SPECIFICATIONS
The following sections detail how the GP-IC-2000 should be wired. Before starting any wiring read and understand these instructions. Wiring should meet all local codes and standards and be performed by qualified personnel such as a licensed electrician.
The NEC (National electrical Code) and CEC (Canadian Electrical Code) provide the standards for safely wiring, wire sizes, over-current protection, installation methods and requirements.
The GP-IC-2000 system can handle power from multiple sources (utility, generator and batteries) which make the wiring hazardous and challenging.
The input and output AC and DC circuits are isolated from the inverter/charger chassis. The Inverter/Charger grounding is the responsibility of the installer in accordance with NEC/CEC or the local electrical codes.
CABLE PROTECTION
All the DC and AC cables leading to / from the GP-IC-2000 must be protected as required by code. This can be accomplished using jacketed (armoured) cable or by feeding the wire through conduit.
CABLE STRAIN RELIEF & TORQUE REQUIREMENTS
The GP-IC-2000 AC input / output terminals can handle multi-core cables up to 1.3” diameter. If using large diameter cable it is highly recommended to use additional (non metallic) cable strain relief clamps mounted outside the Inverter / Charger these will ease the torque and leverage forces which could be present at the cable entry/exit locations.
Torque all AC and DC wiring connections to 16 in lbf (1.8 N-m), make sure the connections are secure and re-check all connections periodically (at least every 6 months, more frequent for heavy RV use) to make sure they remain secure.
CABLE REQUIREMENTS
• Protect all conductors which may be at risk of physical damage by using conduit, tape or place them in a raceway.
• Do not mix AC and DC Wiring in the same conduit or panel. Where DC wiring must cross AC, try to make sure the wires cross perpendicular to each other.
• Both AC and DC over-current protection must be provided.
• The Inverter/Charger requires a reliable negative and ground return path to the battery.
• Use only copper wires with a minimum temperature rating of 75 °C.
CABLE LAYOUT PLANNING
Before connecting any cables, determine all cable routes to / from the GP-IC-2000.
• AC Input cables from the external transfer switch (if using shore and generator).
• DC Input cables from the batteries.
• AC Output cables from the Inverter / Charger to the AC breaker panel.
• Battery Temperature Sensor cable from the Inverter / Charger to the batteries.
• Remote Control cable to the Inverter / Charger.
• Ground wiring to / from the Inverter / Charger.
[page 18] | gpelectric.com
120 VAC
240 VAC
120 VAC
Sub Panel
INSTALLATION
3.5 DC WIRING
Main Panel
The cables linking the GP-IC-2000 to the battery bank are the DC cables. These cables handle the Direct Current power used to charge the batteries (Charging Mode) and power the main appliances (Inverter Mode). It is important to select the correct wire size and to provide adequate over-current protection between the Inverter / Charger and battery bank.
Negative Bus Bar
Equipment Grounding Bus Bar
Earth Ground (RV, Boat Ground)
ON
OFF
GP-IC-2000
DC Panel
Battery Disconnect Switch
(not required if circuit breaker is used)
Fuse or Circuit Breaker
Battery Bank
The following points must be observed for the DC Wiring.
• The DC positive and negative cables connected to the GP-IC-2000 from the battery bank should be linked together with zip ties or electrical tape every 6”. This helps to reduce radio frequency interference and reduces the effects of inductance both of which improve the Inverter / Charger waveform and reduces the wear of the Inverters filter capacitors.
• To ensure optimum Inverter/charger performance the number of connections between the battery bank and the
GP-IC-2000 unit should be minimized except from the over-current and battery disconnect devices. All additional connection points will cause extra voltage drops.
• The Battery bank voltage must match the DC voltage required by the GP-IC-2000, which is 12V. Do not connect a 24V battery bank to the GP-IC-2000.
• All DC cable wire terminations should use a crimped and sealed copper ring terminal lugs. Lugs with an 8mm
(5/16”) hole should be used to connect the DC cables to the Inverter / Chargers DC terminals.
• Make sure all cables have a smooth bend radius and no kinks are present.
• Colour code all DC Cables coming to / from the battery bank. Use coloured electrical tape or heat shrink tubing.
Red for positive (+), Black for negative (-) and Green for DC ground.
gpelectric.com | [page 19]
A
B
BULK ABSORPTION
Battery Charging Voltage
FINAL (FLOAT)
Battery Charging Current
Time
ON
OFF
D
C
INSTALLATION
3.5.1 DC WIRE SIZING
The distance between the battery bank and the GP-IC-2000 should be as short as possible to achieve maximum efficiency and to reduce fire hazards. The cables should be as short as possible and the overall length of both cables added together should be less than 10 ft (3m) to comply with code requirements. Keeping your wire runs as short as possible helps to prevent: low voltage shutdowns and nuisance tripping of the DC breaker because of increased current draw. The table below shows the recommended DC cable size, fuses/circuit breakers and DC grounding cable sizes for the GP-IC-2000 ( Note: these values are correct for cables in free air, not conduit)
DC Cable Size
No. 2/0 AWG
Inline Fuse / Circuit
Breaker
300A Class T
Overall Length of
Positive and Negative
Cable combined
5 ft (1.5m)
Recommended
Go Power! DC Kit
#4
DC Grounding Cable
Size
No. 6 AWG
No. 4/0 AWG 400A Class T 10 ft (3m) #5 No. 6 AWG
3.5.2 DC OVERCURRENT PROTECTION AND DC DISCONNECT
Batteries are capable of providing very large currents in case of a short circuit, if this occurs with no DC overcurrent protection, it will result in overheating and melting of the cables and possibly serious injury and/or fire.
DC overcurrent protection is not included with the GP-IC-2000. It must be installed between the Inverter / Charger and battery bank for safety reasons and to comply with code regulations.
Use a very fast acting DC fuse or circuit breaker in the positive cable, the fuse should be installed as close to possible to the battery positive terminal. Ideally the fuse/circuit breaker should be installed within 18” (45cm of the battery). The fuse required for DC Cable lengths up to 5ft is detailed in the above table.
In all installations a battery disconnect switch is required, if you install a circuit breaker for overcurrent protection this will suffice as a disconnect switch. If you install a fuse for overcurrent protection then a separate disconnect switch will need to be installed.
3.5.3 PREPARING THE DC CABLES
Go Power! supplies 2 ring lugs with the GP-IC-2000 which can be used for the Inverter / Charger end of the DC Cables. Source the correct ring terminals for the batteries you are using.
• Cut the negative and positive cables to the required length.
• Strip off enough insulation so you can install the ring lugs provided.
• Use the correct crimp connector to install the ring lugs.
• Attach the connectors to both ends of both cables. Make sure no stray wire strands protrude from the connectors.
3.5.4 DC CABLE CONNECTIONS
When installing the battery cable ring lug onto the GP-IC-2000 DC terminal and the battery post - do not put anything between the ring lug and the metal surface. Incorrectly installed hardware causes a high resistance connection which could lead to poor
Inverter/Charger performance and may melt the cable and terminal connections. Refer to figures on page 21 to connect the
DC Cables and to install the hardware correctly. Use a 13mm wrench or socket to tighten the M8 x 1.25mm Nuts. Tighten the terminal connections securely and periodically check the connections to make sure they remain tight and secure.
To help prevent seizing and corrosion around the terminals the use of an anti-seize lubricant is highly recommended. Apply the antioxidant grease or spray after all the connections are made and tightened.
[page 20] | gpelectric.com
®
Temperature Sensor
AC INPUT
REMOTE
ON/OFF
STATUS
INV. AC
OUTPUT
NEG -
POS +
4.9” (124mm)
.28” (7mm)
13.6” (346mm)
2” (51mm) 4.9” (124mm)
.51” (13mm)
13.7”
14.9” (378mm)
(349mm)
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
®
Temperature Sensor
®
Temperature Sensor
INSTALLATION
DO NOT INSTALL ANYTHING
BETWEEN RING LUG and DC
TERMINAL
Nut
Split Washer
Washer
Battery Temperature Sensor
Battery Cable (with ring lug)
Battery Post (Negative Terminal)
REMOTE
Inverter / Charger DC Terminal
Battery Cable (with ring lug)
M8mm Washer
M8mm Split Washer
M8mm Nut
DO NOT INSTALL ANYTHING
BETWEEN RING LUG and
BATTERY POST
3.5.5 BATTERY TEMPERATURE SENSOR INSTALLATION
The Battery Temperature Sensor (BTS) extends the life of the battery by preventing overcharging in warm temperatures and undercharging in cold temperatures. The BTS provides the Inverter / Charger with precise battery temperature information to automatically adjust the absorb and float charge voltage set points. If the BTS is NOT installed and the battery bank is subjected to large temperature changes the battery life will be reduced.
• Install the battery temperature sensor ring terminal onto the NEGATIVE battery terminal.
• Route the sensor’s cable to the Inverter / Charger following existing wire runs.
• Connect the RJ11 connector end of the BTS cable to the ‘Battery Temp’ port on the Inverter / Charger.
AC INPUT
REMOTE
BATTERY
TEMP
ON/OFF
INV. / CHR.
MODE
STATUS
®
Temperature Sensor
INV. AC
OUTPUT
NEG
-
POS + gpelectric.com | [page 21]
AC INPUT
REMOTE
BATTERY
TEMP
ON/OFF
INV. / CHR.
MODE
STATUS
INV. AC
OUTPUT
NEG -
POS +
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
- PROTECTED EQUIPMENT IS REQUIRED.
DANGER:
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
AVERTISSEMENT:
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
WARNING:
CONTENANT CHACUNE 6 ou 12 CELLULES.
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
MISE EN GARDE:
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
CAUTION:
AC INPUT
REMOTE
BATTERY
TEMP
ON/OFF
INV. / CHR.
MODE
STATUS
INV. AC
OUTPUT
NEG
-
POS +
4.9” (124mm)
.28” (7mm)
13.6”
2”
(346mm)
(51mm) 4.9” (124mm)
.51” (13mm)
12”
(304mm)
4.9” (124mm)
.28” (7mm)
13.6” (346mm)
2” (51mm) 4.9” (124mm)
.51” (13mm)
12.6”
(321mm) 12.6”
(321mm)
13.7”
14.9”
(349mm)
(378mm)
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
AC INPUT
ON/OFF
8.1” INV. / CHR.
MODE
REMOTE (205mm) STATUS
BATTERY
TEMP
INV. AC
OUTPUT
NEG
-
POS +
13.7”
14.9”
(349mm)
(378mm)
INPUT
50A
INPUT
50A
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
4.9” (124mm)
.28” (7mm)
13.6” (346mm)
2” (51mm) 4.9” (124mm)
.51” (13mm)
8.1”
(205mm)
REMOTE
13.7”
14.9” (378mm)
(349mm)
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
12.6”
(321mm)
AC INPUT
REMOTE
ON/OFF
INV. / CHR.
MODE
STATUS
INV. AC
OUTPUT
NEG
-
POS +
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
AC INPUT
REMOTE
BATTERY
TEMP
ON/OFF
STATUS
INV. AC
OUTPUT
NEG
-
POS +
INPUT
50A
INPUT
50A
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
CB2
50A
CB1
50A
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
- PROTECTED EQUIPMENT IS REQUIRED.
DANGER:
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
AVERTISSEMENT:
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
WARNING:
CONTENANT CHACUNE 6 ou 12 CELLULES.
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
MISE EN GARDE:
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
CAUTION:
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
- PROTECTED EQUIPMENT IS REQUIRED.
DANGER:
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
AVERTISSEMENT:
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
WARNING:
CONTENANT CHACUNE 6 ou 12 CELLULES.
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
MISE EN GARDE:
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
CAUTION:
50A
INPUT
50A
INPUT
AC INPUT
REMOTE
ON/OFF
STATUS
INV. AC
OUTPUT
NEG -
POS +
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
- PROTECTED EQUIPMENT IS REQUIRED.
DANGER:
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
AVERTISSEMENT:
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
WARNING:
CONTENANT CHACUNE 6 ou 12 CELLULES.
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
MISE EN GARDE:
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
CAUTION:
CB2
INPUT
50A
CB1
INPUT
50A
50A
INPUT
CB2
50A
INPUT
CB1
REMOTE
REMOTE
Main Panel
INSTALLATION
WIRING THE INVERTER/CHARGER TO THE BATTERY BANK 3.5.6
WARNING: Lethal currents will be present if the positive and negative cables attached to the battery bank touch each other. During the installation and wiring process, ensure the cable ends are insulated or covered to prevent shorting the cables.
WARNING: DO NOT connect the DC Wires from the battery bank to the GP-IC-2000 until all the DC and AC wiring is complete and the AC and DC overcurrent protection has been installed.
The GP-IC-2000 is a 12V Inverter/Charger so the battery bank must be wired in series, parallel, or series-parallel to provide the correct voltage: 12V. Example battery configurations are shown on page 23. The interconnecting wires between the individual batteries must be sized and rated exactly the same as those used between the battery bank and Inverter / Charger.
For the GP-IC-2000 to perform optimally a 200Ahr battery bank must be used for light/moderate loads (<1000W) and for heavy loads of 1000W> a 400Ahr battery bank is recommended.
To ensure the best performance from your Inverter / Charger system, batteries should be the same size, type, rating and age.
Do not use old or untested batteries.
WARNING: The Inverter / Charger is not reverse polarity protected. If the Inverter / Charger is wired incorrectly severe damage will occur and will not be covered by the warranty. It is advised to clearly mark the positive and negative cables coming from the battery bank. Use red and black electrical tape to clearly indicate positive and negative cables.
240 VAC
DC Positive and Negative Wires
• Connect the negative cable from the battery bank negative terminal to the Inverter / Chargers negative terminal.
Mount the DC circuit breaker or fuse assembly and leave open (no power to the GP-IC-2000). Connect the positive cables from the circuit breaker / fuse to the battery bank and to the Inverter / Chargers positive terminal.
• Ensure the DC wire connections are flush on the surface of the DC terminals and the hardware used to hold these connections are stacked correctly. Verify all DC connections are secured tightly.
• Attach the red and black terminal covers (see below) over the Inverter / Chargers DC connectors and secure them in place with the supplied screws.
BULK ABSORPTION
Battery Charging Voltage
FINAL (FLOAT)
Battery Charging Current
Time
Negative Bus Bar
Equipment Grounding Bus Bar
[page 22] | gpelectric.com
Earth Ground (RV, Boat Ground)
ON
OFF
GP-IC-2000
DC Panel
Battery Disconnect Switch
(not required if circuit breaker is used)
Fuse or Circuit Breaker
Battery Bank
A
B
ON
OFF
D
C
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
12 VDC
(200 AH)
12 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
INSTALLATION
3.5.7 BATTERY BANK CONFIGURATIONS
12 VDC
(400 AH) 12 VDC
(400 AH)
12 VDC
(400 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH) 12 VDC
(100 AH)
(100 AH)
12 VDC
(400 AH) 12 VDC
(200 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(200 AH)
12 VDC
(200 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(400 AH)
12 VDC
(600 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(400 AH)
12 Volt, 400 Amp Hour Battery Bank
Parallel, 4 x 12V Batteries
12 VDC
(600 AH)
(100 AH)
12 VDC
(100 AH)
12 VDC
(600 AH) 12 VDC
(600 AH)
12 VDC
(600 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(600 AH)
12 VDC
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
12 VDC
(100 AH)
12 VDC
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
12 VDC
(100 AH)
12 VDC
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
12 Volt, 600 Amp Hour Battery Bank
Parallel, 6 x 12V Batteries
12 VDC
(100 AH)
12 VDC
(100 AH)
6 VDC
(200 AH)
12 VDC
(200 AH)
12 VDC
(100 AH)
12 VDC
(100 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
12 VDC
6 VDC
(200 AH)
12 VDC
(200 AH)
6 VDC
(200 AH)
12 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
12 VDC
(200 AH)
12 VDC
(100 AH)
6 VDC
(200 AH)
12 VDC
(200 AH)
12 VDC
(100 AH)
12 VDC
(400 AH)
6 VDC
(200 AH)
12 VDC
(100 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
12 VDC
(200 AH)
12 VDC
(400 AH)
6 VDC
(200 AH)
12 VDC
(100 AH)
6 VDC
(200 AH)
(200 AH) 6 VDC
(200 AH)
6 VDC
6 VDC
6 VDC
(200 AH)
12 VDC
(400 AH)
12 VDC
(400 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
12 VDC
(100 AH)
6 VDC
6 VDC
(200 AH)
6 VDC
(200 AH)
(200 AH)
12 VDC
(600 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
6 VDC
(200 AH)
(200 AH)
6 VDC
6 VDC
(200 AH)
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
12 VDC
(600 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
12 VDC
(600 AH)
12 VDC
(600 AH)
12 VDC
(600 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
12 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
12 VDC
(400 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
12 VDC
(600 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
6 VDC
(200 AH)
12 Volt, 400 Amp Hour Battery Bank
Series & Parallel, 4 x 6V Batteries
6 VDC
(200 AH)
6 VDC
(200 AH) gpelectric.com | [page 23]
®
Temperature Sensor
4.9” (124mm)
.28” (7mm)
13.6” (346mm)
2” (51mm) 4.9” (124mm)
.51” (13mm)
12.6”
(321mm)
INSTALLATION
3.5.8 DC GROUNDING
To protect against electrical shock hazards the GP-IC-2000 metal chassis must be connected to the DC grounding system. The
DC grounding system is sometimes referred to as the Earth ground or another designated ground. For example on an RV, the metal frame of the RV is designated as the negative DC ground / RV ground. On a boat, the ground is simply referred to as boat ground.
The GP-IC-2000 consists of a DC and an AC section that are isolated through a transformer. Both these sections are required to be grounded appropriately.
The DC ground wire connection on the GP-IC-2000 is used to connect the exposed chassis of the Inverter / Charger to the DC grounding system. Use copper wire that is either bare or provided with green insulation. This terminal accepts CU/AL conductors from #14 to #2 AWG (2.1 to 33.6mm2). The size of this conductor should be coordinated with the size of the over-current devices used.
240 VAC
In Marine Applications the DC Ground wire has to be the same size as the battery negative cable. To attach a larger gauge wire follow these steps;
• Remove the M8mm nut and star washer holding the DC ground wire to the metal chassis.
connection boss
• Remove the connection boss and store safely.
AC INPUT
BATTERY
TEMP
• Attach the correctly sized ground cable with a ring terminal to the GP_IC-2000 Chassis, the ring terminal must have a hole size ≥ 1/4”.
INV. AC
OUTPUT
• Place the M8mm nut and star washer over the ground cable and securely tighten the nut.
DC grounding involves proper grounding of the negative of the battery, the DC panel and the DC side of the GP-IC-2000. the DC panel is normally used to connect the batteries and distribute DC power to the Inverter / Charger and to the other DC loads.
A common earth ground should be used to bond the Inverter/Charger, negative bus bar and the negative battery terminal.
All connections must be tight against bare metal. Use star washers to penetrate paint and corrosion.
ON/OFF
INV. / CHR.
MODE
STATUS
NEG
-
POS +
BULK
Main Panel
ABSORPTION
13.7”
14.9”
(349mm)
(378mm)
120 VAC
Battery Charging Voltage
FINAL (FLOAT)
Sub Panel
240 VAC
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
120 VAC
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
Battery Charging Current
Time
Negative Bus Bar
Equipment Grounding Bus Bar
Earth Ground (RV, Boat Ground)
ON
OFF
GP-IC-2000
DC Panel
Battery Disconnect Switch
(not required if circuit breaker is used)
Fuse or Circuit Breaker
Battery Bank
A
Negative Bus Bar
Equipment Grounding Bus Bar
B
Earth Ground (RV, Boat Ground)
ON
OFF
D
C
ON
OFF
GP-IC-2000
DC Panel
Battery Disconnect Switch
(not required if circuit breaker is used)
Fuse or Circuit Breaker
Battery Bank
[page 24] | gpelectric.com
A
B
8.1”
ABSORPTION
Battery Charging Voltage
FINAL (FLOAT)
Battery Charging Current
CB2
50A
CB1
50A
Time
ON
OFF
D
C
AC INPUT
REMOTE
BATTERY
TEMP
ON/OFF
INV. / CHR.
MODE
STATUS
INV. AC
OUTPUT
NEG -
POS +
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
- PROTECTED EQUIPMENT IS REQUIRED.
DANGER:
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
AVERTISSEMENT:
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
WARNING:
CONTENANT CHACUNE 6 ou 12 CELLULES.
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
MISE EN GARDE:
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
CAUTION:
INPUT
50A
INPUT
50A
50A
INPUT
50A
INPUT
REMOTE
INSTALLATION
3.6 AC WIRING
The cables linking the GP-IC-2000 to the main panel and the sub panel are the AC cables. These cables handle the incoming alternating current (AC) utility or generator power which can be passed through the Inverter / Charger to directly power the main appliances (pass through mode) and/or used to charge the batteries (charging mode). It is important to select the correct wire size and to provide adequate over-current protection between the Inverter / Charger main panel and sub panel.
120 VAC
240 VAC
(Cabin)
120 VAC
Sub Panel
Main Panel
The following points must be observed for the AC Wiring
• Review the safety information at the start of this manual before completing any AC wire installation steps.
• All AC Wiring must be approved for the application (RV, Marine, Residential). For RV applications, this may be solid wire in multi-conductor cables, but stranded wire is required if single conductors are used.
• All wiring must be rated to 75°C or higher.
GP-IC-2000
• Do not connect the AC Output to an AC Power source (generator / shore power). Severe damage may occur and will not be covered under the warranty.
• Always use properly rated circuit breakers / fuses.
Negative Bus Bar
• Color code and label all AC Cables coming to / from the GP-IC-2000. Use colored electrical tape or heat shrink tubing.
OFF
DC Panel
Battery Disconnect Switch
(not required if circuit breaker is used)
• Make sure all cables have a smooth bend radius and no kinks are present.
Earth Ground (RV, Boat Ground) Fuse or Circuit Breaker
Battery Bank gpelectric.com | [page 25]
A
B
BULK ABSORPTION
Battery Charging Voltage
FINAL (FLOAT)
Battery Charging Current
Time
ON
OFF
D
C
INSTALLATION
3.6.1 AC POWER SOURCE TYPES
AC Input power to the GP-IC-2000 can be supplied from a split-phase or dual-input single phase AC source. These sources typically include utility power or a generator.
• Split Phase: This source has 4 lines: 2 hot lines, one neutral and one ground. The 2 hot lines are 120VAC and are 180 degrees out of phase with each other, so that the 2 voltages equal 240VAC. The voltage between each hot line and neutral is 120VAC and the voltage between the neutral and ground is approximately zero. Because the 2 lines are out of phase, the currents from each line subtract in the neutral, and the neutral current will be approximately zero if the loads on each line are equal. For example if Hot 1 is supplying 20A and Hot 2 is supplying
15A, the current in the neutral will be 5A.
• Dual Input: This source has 4 lines: 2 Hot lines, one neutral and one ground. The 2 Hot Lines are 120VAC and are in phase and must come from the same source. The voltage between the 2 hot lines is zero. The voltage between each hot line and the neutral is 120VAC and the voltage between the neutral and the ground is approximately zero.
Because the 2 lines are in phase, the currents from each line add together in the neutral. For example if Hot 1 is supplying 20A and Hot 2 is supplying 15A, the current in the neutral will be 35A.
3.6.2 AC WIRE SIZE AND OVERCURRENT PROTECTION
The wires used for the Input AC and Output AC must be sized to meet local electrical safety requirements. The AC wiring must be protected from short circuits and overloads by an overcurrent protection device, these requirements are usually met using a main panel and sub panel (with suitable circuit breakers/fuses installed) located before and after the Inverter / Charger as shown on pages 30 - 33.
CAUTION: The GP-IC-2000 inverters internal transfer contacts are rated for 50 amps, the pass-thru current for relay contact must be no greater than 50 amps or damage to this relay may occur.
3.6.3 GFCI (GROUND FAULT CIRCUIT INTERRUPTION) OUTLETS
Compliance with UL standards requires that Go Power! test and recommend specific GFCIs for use on the AC output of the
GP-IC-2000. GFCIs shall be installed in the AC output wiring system to protect all branch circuits.
A GFCI is a device that de–energizes a circuit when a current exceeds a specified value that is less than that required to open the circuit breaker. GFCIs are intended to protect people from electric shocks and are usually required in wet or damp locations.
The table below lists GFCIs that have been tested and will function properly when connected to the AC output of the GP-IC-2000.
Manufacturer
Cooper Wiring Devices
Leviton Mfg Co Inc
Hubbell Inc Wiring Device Dev
Pass & Seymour Inc
Model Number
SGF20
GFNT2
GFRST20
2097
[page 26] | gpelectric.com
3.6.4 AC TERMINAL BLOCK CONNECTIONS
IN1
IN2
ACN-IN
OUT1
OUT2
ACN-OUT
INSTALLATION
AC cover plate removed
Phillips screw boss x3
Terminal label
IN1
IN2
OUT1
OUT2
ACN-OUT
AC ground IN
(from main panel)
The GP-IC-2000 has a six-pole AC terminal block and two AC ground terminals to connect the Inverter / Chargers AC input and output wiring.
The terminal block and ground terminals can be accessed by removing the three Phillips screws holding the AC cover plate.
Each connection on the AC terminal block is rated to accept one #14 to #6 AWG CU stranded wire, or two #12 AWG CU stranded wires. Use a flat head screwdriver to release and tighten the set screws.
The AC ground terminals can accept two #14 to #6 AWG CU stranded wire. Use a flat head screwdriver to release and tighten the set screws.
The GP-IC-2000’s ACN-IN and ACN-OUT terminals are electrically isolated from each other when in ‘inverting mode’ this helps to prevent ground-loops. If the installation requires the AC Input and AC Output neutrals to be connected together, the Inverter
/ Chargers neutral-to-ground connection must be disconnected (See section 3.6.11).
gpelectric.com | [page 27]
UNIT
ON/OFF
CHARGER
ON/OFF
UNIT
ON/OFF
CHARGER
ON/OFF
SHORE POWER
UNIT READINGS
UNIT SETUP
REMOTE SETTINGS
SHORE POWER
UNIT READINGS
UNIT SETUP
REMOTE SETTINGS
INSTALLATION
3.6.5 AC CONDUCTOR WIRING
Make sure the GP-IC-2000 is fully disconnected from the battery bank and no AC power is connected to the
Inverter / Charger before commencing any AC wiring connections
AC INPUTS WIRING (50A Dual IN, Dual Out Configuration)
• Remove the AC cover plate.
• Route the wires: IN1 (Hot1), IN2 (Hot2), ACN-IN (neutral), and Ground from the main panel through the AC Input strain relief clamp. Tighten the strain relief clamp securely on the wires. Always leave a little extra slack in the wiring.
• Connect the HOT1 wire (black) from the main panel to the Inverter / Chargers IN1 terminal. Connect the HOT2 wire (red) from the main panel to the Inverter / Chargers IN2 terminal. Tighten the terminals securely. Note: To use the Battery Charger - IN1 must always be connected to an AC Input.
• Connect the NEUTRAL (white) from the main panel to the Inverter / Chargers ACN-IN terminal. Tighten the terminal securely.
IN 1
AC Live from main panel
IN 2
AC Live from main panel
ACN-IN
AC Neutral from main panel
Main Panel
AC OUTPUTS WIRING
OUT 1
AC Live to sub panel
• Route the wires (hot, neutral, and ground) from the sub panel through the AC INV. Output strain relief clamp.
Tighten the strain relief clamp securely on the wires. Always leave a little extra slack in the wiring.
OUT 2
AC Live to sub panel
• Connect the OUT1 wire (black) and OUT2 (red) from the Inverter / Charger to the sub panel. Tighten the terminals securely.
Sub Panel
• To prevent possible damage to the case, always add additional external non-conductive strain relief when using large diameter multi-conductor cables for AC inputs and AC outputs.
AC Neutral from main panel
Main Panel
OUT 1
AC Live to sub panel
OUT 2
AC Live to sub panel
ACN-OUT
AC Neutral to sub panel
Sub Panel
[page 28] | gpelectric.com
INSTALLATION
AC GROUND WIRING
• Connect the ground (Green) wire from the main panel to the AC Ground IN terminal. Tighten the terminal securely.
Note: The Ground terminals are lugs and they are not labelled within the compartment, see diagram below.
ACN-IN
OUT1
OUT2
ACN-OUT
IN1
IN2
ACN-IN
OUT1
OUT2
AC Ground IN
(from main panel)
ACN-OUT
AC Ground OUT
(to sub panel) size : 55x36.5mm
AC WIRING CHECKS
• Ensure all wires are secured. In RV applications use zip ties or other non-conductive fasteners to prevent chaffing or damage from movement and vibration.
• Ensure strain reliefs or grommets are in place to prevent damage to the wiring or conduit where it passes through the walls/bulkheads or other openings.
• If using large diameter multi core cable add additional external non-conductive strain relief(s) to prevent damage to the Inverter / Charger case.
• After checking all AC connections and ensuring all the terminal set screws are tightened securely, replace the AC
Cover Plate, 3 x Phillips set screws and the covers on the main and sub panels.
AC WIRING FOR MARINE APPLICATIONS
To comply with ABYC requirements for marine installations, all wire connections into the AC terminal blocks must be protected with stainless steel wire protectors such as pin terminals to prevent wire damage from the set screw. gpelectric.com | [page 29]
INSTALLATION
3.6.6 AC WIRING 1 - Single Phase, ≤30A Service, Single IN / Single OUT
AC Power
Source
Single Phase - ≤30 Amp Service
120 VAC
≤ 30 Amps - 120VAC
Hot1 Only
Shore Power
120 VAC
Generator Power
120 VAC
Maximum
Input
Breaker required
30A
(Single Pole Breaker)
Minimum
Wire
Size
Maximum
Inverter
Pass
Through
Capacity
#10 AWG
(Input & Output)
3600W
30A @ 120VAC
Hot 1 (Black)
Main Panel
30A
External
Transfer Switch
(only required if using a hardwired generator and shore power)
Neutral Bus Bar
Ground Bus Bar
Maximum 30A Breaker
(single pole)
#10 AWG
AC Terminal Block
IN 1
AC Hot 1 from main panel
ACN-IN
AC Neutral from main panel
OUT 1
AC Live to sub panel
ACN-OUT
AC Neutral to sub panel
AC Ground
AC Ground from main panel
AC Ground
AC Ground to sub panel
GP-IC-2000
#10 AWG
AC Terminal Block
IN 1
AC Hot 1
IN 2
AC Hot 2
ACN-IN
AC Neutral
OUT 1
AC Live to sub panel
OUT 2
AC Live to sub panel
ACN-OUT
AC Neutral to sub panel
AC Power
Source
Split Phase - ≤50 Amp Service
Install Option 2
120 / 240 VAC
50 Amps per 120 VAC leg.
Hot 1 + Hot 2.
Maximum
Input
Breaker
CB1 : 50A
(located within the GP-IC-2000)
CB2 : 50A
(located within the GP-IC-2000)
Minimum
Wire
Size
#6 AWG
(Input & Output)
12000W
Maximum
Inverter
Pass
Through
Capacity
50A @ 120VAC (Hot 1)
50A @ 120VAC (Hot 2)
Note: Loads must be correctly balanced between both phases (Hot 1 and Hot 2) on the breaker panels in order to get maximum capacity
AC Ground
AC Ground from main panel
AC Ground
AC Ground to sub panel
Sub Panel
Notes:
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
Ground Bus Bar Neutral Bus Bar
Notes:
* Using wiring option 2 for 50 Amp service will allow all AC devices to be powered from the GP-IC-2000 in Inverting mode. Running devices that use more than 2000W will cause the GP-IC-2000 to go into overload.
Operating high current draw loads (such as air conditioning units) could severely deplete the battery bank power quickly.
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
Ground Bus Bar
Shore Power
120/240 VAC
Generator Power
120/240 VAC
CB2: 50A Breaker CB1: 50A Breaker
GP-IC-2000
Sub Panel
External
Transfer Switch
(only required if using a hardwired generator and shore power)
#6 AWG
#6 AWG
Neutral Bus Bar
120 VAC
GFCI
Outlet
120 VAC
GFCI
Outlet
240 VAC
GFCI
Outlet
120 VAC
GFCI
Outlet
[page 30] | gpelectric.com
INSTALLATION
3.6.7 AC WIRING 2 -
Single Phase, 30A> Service, Single IN / Single OUT
AC Power
Source
Single Phase - 30> Amp Service
120 VAC
≤ 25 Amps a Leg
Shore Power
120 VAC
Generator Power
120 VAC
Maximum
Input
Breaker required
50A
(Single Pole Breaker)
External
Transfer Switch
(only required if using a hardwired generator and shore power)
Minimum
Wire
Size
#8 AWG
(Input & Output)
Maximum
Inverter
Pass
Through
Capacity
6000W
50A @ 120VAC (Hot 1 + Hot 2)
Hot 1 (Black)
Main Panel
50A
Neutral Bus Bar
Ground Bus Bar
Maximum 50A Breaker
(single pole)
#8 AWG
AC Terminal Block
IN 1
AC Hot 1 from main panel
IN 2
AC Hot 2 from main panel
ACN-IN
AC Neutral from main panel
OUT 1
AC Live to sub panel
OUT 2
AC Live to sub panel
ACN-OUT
AC Neutral to sub panel
AC Ground
AC Ground from main panel
AC Ground
AC Ground to sub panel
GP-IC-2000
#8 AWG
AC Terminal Block
IN 1
AC Hot 1 from main panel
IN 2
AC Hot 2 from main panel
ACN-IN
AC Neutral from main panel
OUT 1
AC Live to sub panel
OUT 2
AC Live to sub panel
ACN-OUT
AC Neutral to sub panel
AC Power
Source
Maximum
Input
Breaker required
Split Phase - ≤50 Amp Service
Install Option 1
120 / 240 VAC
50 Amps per 120 VAC leg.
Hot 1 + Hot 2.
Hot 1 (Leg 1)
50A
(Single Pole Breaker)
Hot 2 (Leg 2)
50A
(Single Pole Breaker)
#6 AWG
(Input & Output)
Minimum
Wire
Size
12000W
Maximum
Inverter
Pass
Through
Capacity
50A @ 120VAC (Hot 1)
50A @ 120VAC (Hot 2)
Note: Loads must be correctly balanced between both phases (Hot 1 and Hot 2) on the breaker panels in order to get maximum capacity
Hot 1 (Black)
Hot 2 (Red)
AC Ground
AC Ground from main panel
AC Ground
AC Ground to sub panel
Sub Panel
Notes:
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
Ground Bus Bar Neutral Bus Bar
Notes:
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
Ground Bus Bar
Shore Power
120/240 VAC
Generator Power
120/240 VAC
Main Panel
50A 50A
GP-IC-2000
Sub Panel
External
Transfer Switch
(only required if using a hardwired generator and shore power)
Neutral Bus Bar
Ground Bus Bar
#6 AWG
#6 AWG
Neutral Bus Bar
120 VAC
GFCI
Outlet
120 VAC
GFCI
Outlet gpelectric.com | [page 31]
240 VAC
GFCI
Outlet
120 VAC
GFCI
Outlet
AC Power Source
Ground
AC Power from Utility or
Generator
ACN-IN (White)
AC Neutral Input
2
AC Neutral to AC Source Ground
Transfer Relay Connected
GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
Main Chassis
Earth Ground
2
AC Neutral to Chassis
Ground Disconnected
ACN-OUT (Black)
AC Neutral to sub panel
AC Power Source
Ground
AC Power from Utility or
Generator
ACN-IN (White)
AC Neutral Input
AC Neutral to AC Source Ground
Transfer Relay Connected
GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
Main Chassis
Earth Ground
Screw Removed x
AC Neutral to Chassis
Ground - Permanently
Disabled
ACN-OUT (Black)
AC Neutral to sub panel
AC Power Source
Ground
1
ACN-IN (White)
AC Neutral Input
AC Neutral to AC Source Ground
Transfer Relay Disconnected
GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
Main Chassis (RV, Boat)
Earth Ground
1
AC Neutral to Chassis
Ground Connected
ACN-OUT (Black)
AC Neutral to sub panel
AC Power
Source
Single Phase - 30> Amp Service
120 VAC
≤ 25 Amps a Leg
Maximum
Input
Breaker required
50A
(Single Pole Breaker)
Minimum
Wire
Size
#8 AWG
(Input & Output)
Maximum
Inverter
Pass
Through
Capacity
6000W
50A @ 120VAC (Hot 1 + Hot 2)
Hot 1 (Black)
AC Terminal Block
IN 1
AC Hot 1 from main panel
IN 2
AC Hot 2 from main panel
ACN-IN
AC Neutral from main panel
OUT 1
AC Live to sub panel
OUT 2
AC Live to sub panel
ACN-OUT
AC Neutral to sub panel
Notes:
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
AC Ground
AC Ground from main panel
AC Ground
AC Ground to sub panel
Ground Bus Bar
Shore Power
120 VAC
Generator Power
120 VAC
Main Panel
GP-IC-2000
Sub Panel
50A
External
Transfer Switch
(only required if using a hardwired generator and shore power)
Neutral Bus Bar
Ground Bus Bar
Maximum 50A Breaker
(single pole)
3.6.8 AC WIRING 3 -
Split Phase, 50A Service, Dual IN, Dual OUT,
Option 1
Split Phase - ≤50 Amp Service
Install Option 1
AC Power
Source
Maximum
Input
Breaker required
Minimum
Wire
Size
120 / 240 VAC
50 Amps per 120 VAC leg.
Hot 1 + Hot 2.
Hot 1 (Leg 1)
50A
(Single Pole Breaker)
Hot 2 (Leg 2)
50A
(Single Pole Breaker)
#6 AWG
(Input & Output)
Shore Power
120/240 VAC
Main Panel
Generator Power
120/240 VAC
Hot 1 (Black)
Hot 2 (Red)
12000W
Maximum
Inverter
Pass
Through
Capacity
50A @ 120VAC (Hot 1)
50A @ 120VAC (Hot 2)
Note: Loads must be correctly balanced between both phases (Hot 1 and Hot 2) on the breaker panels in order to get maximum capacity
50A 50A
#8 AWG
#8 AWG
AC Terminal Block
IN 1
AC Hot 1 from main panel
IN 2
AC Hot 2 from main panel
ACN-IN
AC Neutral from main panel
OUT 1
AC Live to sub panel
OUT 2
AC Live to sub panel
ACN-OUT
AC Neutral to sub panel
AC Ground
AC Ground from main panel
AC Ground
AC Ground to sub panel
GP-IC-2000
Sub Panel
Neutral Bus Bar
Notes:
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
Ground Bus Bar
External
Transfer Switch
(only required if using a hardwired generator and shore power)
Neutral Bus Bar
Ground Bus Bar
#6 AWG
#6 AWG
Neutral Bus Bar
120 VAC
GFCI
Outlet
120 VAC
GFCI
Outlet
240 VAC
GFCI
Outlet
120 VAC
GFCI
Outlet
[page 32] | gpelectric.com
AC Power Source
Ground
AC Power from Utility or
Generator
ACN-IN (White)
AC Neutral Input
2
AC Neutral to AC Source Ground
Transfer Relay Connected
GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
Main Chassis
Earth Ground
2
AC Neutral to Chassis
Ground Disconnected
ACN-OUT (Black)
AC Neutral to sub panel
AC Power Source
Ground
AC Power from Utility or
Generator
ACN-IN (White)
AC Neutral Input
AC Neutral to AC Source Ground
Transfer Relay Connected
GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
Main Chassis
Earth Ground
Screw Removed x
AC Neutral to Chassis
Ground - Permanently
Disabled
ACN-OUT (Black)
AC Neutral to sub panel
AC Power Source
Ground
1
ACN-IN (White)
AC Neutral Input
AC Neutral to AC Source Ground
Transfer Relay Disconnected
GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
Main Chassis (RV, Boat)
Earth Ground
1
AC Neutral to Chassis
Ground Connected
ACN-OUT (Black)
AC Neutral to sub panel
AC Power
Source
Single Phase - ≤30 Amp Service
120 VAC
≤ 30 Amps - 120VAC
Hot1 Only
Maximum
Input
Breaker required
30A
(Single Pole Breaker)
Minimum
Wire
Size
Maximum
Inverter
Pass
Through
Capacity
#10 AWG
(Input & Output)
3600W
30A @ 120VAC
AC Terminal Block
IN 1
AC Hot 1 from main panel
ACN-IN
AC Neutral from main panel
OUT 1
AC Live to sub panel
ACN-OUT
AC Neutral to sub panel
Notes:
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
Hot 1 (Black)
AC Ground
AC Ground from main panel
AC Ground
AC Ground to sub panel
Ground Bus Bar
Shore Power
120 VAC
Generator Power
120 VAC
Main Panel
GP-IC-2000
Sub Panel
30A
External
Transfer Switch
(only required if using a hardwired generator and shore power)
Neutral Bus Bar
Ground Bus Bar
Maximum 30A Breaker
(single pole)
3.6.9 AC WIRING 4 -
Split Phase, 50A Service, Dual IN, Dual OUT,
Option 2
Split Phase - ≤50 Amp Service
Install Option 2
AC Power
Source
120 / 240 VAC
50 Amps per 120 VAC leg.
Hot 1 + Hot 2.
Shore Power
120/240 VAC
Generator Power
120/240 VAC
Maximum
Input
Breaker
CB1 : 50A
(located within the GP-IC-2000)
CB2 : 50A
(located within the GP-IC-2000)
Minimum
Wire
Size
#6 AWG
(Input & Output)
12000W
Maximum
Inverter
Pass
Through
Capacity
50A @ 120VAC (Hot 1)
50A @ 120VAC (Hot 2)
Note: Loads must be correctly balanced between both phases (Hot 1 and Hot 2) on the breaker panels in order to get maximum capacity
#10 AWG
#10 AWG
AC Terminal Block
IN 1
AC Hot 1
IN 2
AC Hot 2
ACN-IN
AC Neutral
OUT 1
AC Live to sub panel
OUT 2
AC Live to sub panel
ACN-OUT
AC Neutral to sub panel
AC Ground
AC Ground from main panel
AC Ground
AC Ground to sub panel
CB2: 50A Breaker CB1: 50A Breaker
GP-IC-2000
Sub Panel
Neutral Bus Bar
Notes:
* Using wiring option 2 for 50 Amp service will allow all AC devices to be powered from the GP-IC-2000 in Inverting mode. Running devices that use more than 2000W will cause the GP-IC-2000 to go into overload.
Operating high current draw loads (such as air conditioning units) could severely deplete the battery bank power quickly.
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
Ground Bus Bar
External
Transfer Switch
(only required if using a hardwired generator and shore power)
#6 AWG
#6 AWG
Neutral Bus Bar
120 VAC
GFCI
Outlet
120 VAC
GFCI
Outlet
240 VAC
GFCI
Outlet
120 VAC
GFCI
Outlet gpelectric.com | [page 33]
AC Power
Source
Maximum
Input
Breaker required
Minimum
Wire
Size
Maximum
Inverter
Pass
Through
Capacity
AC Terminal Block
AC Power Source
Ground
Single Phase - 30> Amp Service
120 VAC
≤ 25 Amps a Leg
50A
(Single Pole Breaker)
IN 2
AC Hot 2 from main panel
ACN-IN
AC Neutral from main panel
OUT 1
AC Live to sub panel
#8 AWG
(Input & Output)
6000W
50A @ 120VAC (Hot 1 + Hot 2)
IN 1
AC Hot 1 from main panel
OUT 2
AC Live to sub panel
ACN-OUT
AC Neutral to sub panel
Notes:
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
AC Power from Utility or
Generator
ACN-IN (White)
AC Neutral Input
Main Chassis
Earth Ground
GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
Hot 1 (Black)
AC Ground
AC Ground from main panel
AC Ground
AC Ground to sub panel
2
Ground Bus Bar
AC Neutral to AC Source Ground
Transfer Relay Connected
Shore Power
120 VAC
Main Panel
GP-IC-2000
Sub Panel
120 VAC
GFCI
Outlet
2
AC Neutral to Chassis
Ground Disconnected
Generator Power
120 VAC
50A
120 VAC
GFCI
Outlet
ACN-OUT (Black)
AC Neutral to sub panel
Split Phase - ≤50 Amp Service
Install Option 1
AC Power
Source
120 / 240 VAC
50 Amps per 120 VAC leg.
Hot 1 + Hot 2.
Maximum
Input
Breaker required
Shore Power
120/240 VAC
Generator Power
120/240 VAC
Hot 1 (Leg 1)
50A
(Single Pole Breaker)
Hot 2 (Leg 2)
50A
(Single Pole Breaker)
External
Transfer Switch
(only required if using a hardwired generator and shore power)
External
Transfer Switch
(only required if using a hardwired generator and shore power)
Minimum
Wire
Size
#6 AWG
(Input & Output)
Main Panel
Neutral Bus Bar
Hot 1 (Black)
Hot 2 (Red)
Neutral Bus Bar
Ground Bus Bar
Maximum 50A Breaker
(single pole)
#8 AWG
#8 AWG
Neutral Bus Bar
12000W
Maximum
Inverter
Pass
Through
Capacity
50A @ 120VAC (Hot 1)
50A @ 120VAC (Hot 2)
Note: Loads must be correctly balanced between both phases (Hot 1 and Hot 2) on the breaker panels in order to get maximum capacity
50A 50A
Ground Bus Bar
Single Phase - 30> Amp Service
Split Phase - ≤50 Amp Service
Install Option 1
#6 AWG
120 VAC
120 / 240 VAC
AC Power
Source
AC Terminal Block
≤ 25 Amps a Leg
AC Power
Source 50 Amps per 120 VAC leg.
Hot 1 + Hot 2.
IN 1
AC Hot 1 from main panel
Shore Power
120 VAC
Generator Power
120 VAC
Maximum
Input
Breaker required
IN 2
50A
ACN-IN
(Single Pole Breaker)
AC Neutral from main panel
OUT 1
AC Live to sub panel
AC Ground
AC Ground from main panel
Minimum
Wire
Size
OUT 2
#8 AWG
(Input & Output)
Hot 1 (Black)
ACN-OUT
AC Neutral to sub panel
AC Ground
AC Ground to sub panel
Maximum
Inverter
Pass
Through
Capacity
3.6.10 GROUNDING THE INVERTER - AC GROUNDING
Notes:
6000W
50A @ 120VAC (Hot 1 + Hot 2)
Main Panel
GP-IC-2000
External
Transfer Switch
(only required if using a hardwired generator and shore power)
#6 AWG
Neutral Bus Bar
INSTALLATION
Maximum 50A Breaker
(single pole)
Neutral Bus Bar
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
#8 AWG
The GP-IC-2000 should always be connected to a permanent, grounded wiring system. An Inverter / Charger system that is properly grounded will reduce the risk of electric shock, reduce radio frequency noise. The main aim of any grounding system is to provide a well defined, very low resistance path from the electrical system to the grounding system. The low resistance grounding path carries fault currents directly to ground if the electrical system malfunctions.
AC Terminal Block
IN 1
The neutral and safety ground should be connected at the AC source. The AC source could be shore power (utility power), generator or the Inverter (battery bank). The AC neutral should be connected to one safety ground at a time , this single connection is required to make the electrical panels neutral line safe by connecting it to ground. If more than one connection between the neutral and ground is made, currents can circulate between neutral and ground and cause ground loop currents.
240 VAC 120 VAC
GFCI
Outlet
Ground loop currents can trip GFCIs and cause an electric shock hazard.
AC Neutral from main panel
When using the GP-IC-2000 in Inverting mode and having multiple other AC power sources (shore or generator power), there is the potential of having multiple connections between neutral and ground. The GP-IC-2000 automatically switches the neutral to ground when switching from Inverting to AC Pass through mode.
#8 AWG
In Inverting mode the relays switch to position 1. This means the AC neutral output is connected to the chassis ground on the
GP-IC-2000 which is usually connected to the Earth ground on the RV, work truck or boat.
ACN-OUT
AC Neutral to sub panel
AC Ground
AC Ground to sub panel
Maximum
Input
Breaker required
Minimum
Wire
Size
Hot 1 (Leg 1)
50A
(Single Pole Breaker)
Hot 2 (Leg 2)
50A
(Single Pole Breaker)
IN 1
AC Hot 1 from main panel
IN 2
AC Hot 2 from main panel
OUT 1
AC Live to sub panel
OUT 2
AC Live to sub panel
ACN-OUT
AC Neutral to sub panel
#6 AWG
(Input & Output)
12000W
Maximum
Inverter
Pass
Through
Capacity
50A @ 120VAC (Hot 1)
50A @ 120VAC (Hot 2)
Note: Loads must be correctly balanced between both phases (Hot 1 and Hot 2) on the breaker panels in order to get maximum capacity
ACN-IN
AC Neutral from main panel
Hot 1 (Black)
Hot 2 (Red)
AC Ground
AC Ground from main panel
AC Ground
AC Ground to sub panel
ACN-IN (White)
AC Neutral Input
Notes:
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
1
Ground Bus Bar
Sub Panel
ACN-OUT (Black)
AC Neutral to sub panel
Neutral Bus Bar
Notes:
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
Ground Bus Bar
AC Neutral to AC Source Ground
Transfer Relay Disconnected
1
AC Power Source
Ground GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
AC Neutral to Chassis
Ground Connected
120 VAC
GFCI
Outlet
Main Chassis (RV, Boat)
Earth Ground
120 VAC
GFCI
Outlet
Shore Power
120/240 VAC
Main Panel
50A
GP-IC-2000
Sub Panel
50A
240 VAC
GFCI
Outlet
Generator Power
120/240 VAC
120 VAC
GFCI
Outlet
External
Transfer Switch
(only required if using a hardwired generator and shore power)
Neutral Bus Bar
Ground Bus Bar
#6 AWG
#6 AWG
Neutral Bus Bar
AC Power Source
Ground
AC Power from Utility or
Generator
ACN-IN (White)
AC Neutral Input
AC Neutral to AC Source Ground
Transfer Relay Connected
GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
Main Chassis
Earth Ground
Screw Removed x
AC Neutral to Chassis
Ground - Permanently
Disabled
ACN-OUT (Black)
AC Neutral to sub panel
In AC Pass through mode the relays switch to position 2. The chassis ground to neutral output on the GP-IC-2000 is disconnected and the AC power source neutral to ground (usually located at utility panel or generator) is used to provide the neutral to ground for the AC power being used in the RV, work truck or boat.
AC Power Source
Ground
AC Power from Utility or
Generator
ACN-IN (White)
AC Neutral Input
2
AC Neutral to AC Source Ground
Transfer Relay Connected
GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
2
AC Neutral to Chassis
Ground Disconnected
ACN-OUT (Black)
AC Neutral to sub panel
AC Power Source
Ground
Main Chassis
Earth Ground
Main Chassis (RV, Boat)
Earth Ground
1
ACN-IN (White)
AC Neutral Input
AC Neutral to AC Source Ground
Transfer Relay Disconnected
GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
1
AC Neutral to Chassis
Ground Connected
ACN-OUT (Black)
AC Neutral to sub panel
[page 34] | gpelectric.com
AC Power from Utility or
Generator
ACN-IN (White)
AC Neutral Input
AC Power Source
Ground
AC Neutral to AC Source Ground
Transfer Relay Connected
GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
Main Chassis
Earth Ground
Screw Removed x
AC Neutral to Chassis
Ground - Permanently
Disabled
ACN-OUT (Black)
AC Neutral to sub panel
AC Power
Source
Single Phase - 30> Amp Service
120 VAC
≤ 25 Amps a Leg
Maximum
Input
Breaker required
50A
(Single Pole Breaker)
Minimum
Wire
Size
#8 AWG
(Input & Output)
Maximum
Inverter
Pass
Through
Capacity
6000W
50A @ 120VAC (Hot 1 + Hot 2)
Hot 1 (Black)
Shore Power
120 VAC
Generator Power
120 VAC
Main Panel
50A
External
Transfer Switch
(only required if using a hardwired generator and shore power)
Neutral Bus Bar
Ground Bus Bar
Maximum 50A Breaker
(single pole)
AC Power
Source
Maximum
Input
Breaker required
Split Phase - ≤50 Amp Service
Install Option 1
120 / 240 VAC
50 Amps per 120 VAC leg.
Hot 1 + Hot 2.
Hot 1 (Leg 1)
50A
(Single Pole Breaker)
Hot 2 (Leg 2)
50A
(Single Pole Breaker)
#6 AWG
(Input & Output)
Minimum
Wire
Size
12000W
Maximum
Inverter
Pass
Through
Capacity
50A @ 120VAC (Hot 1)
50A @ 120VAC (Hot 2)
Note: Loads must be correctly balanced between both phases (Hot 1 and Hot 2) on the breaker panels in order to get maximum capacity
Hot 1 (Black)
Hot 2 (Red)
Shore Power
120/240 VAC
Generator Power
120/240 VAC
Main Panel
50A 50A
External
Transfer Switch
(only required if using a hardwired generator and shore power)
Neutral Bus Bar
Ground Bus Bar
#8 AWG #6 AWG
AC Terminal Block AC Terminal Block
IN 1
AC Hot 1 from main panel
IN 2
AC Hot 2 from main panel
ACN-IN
AC Neutral from main panel
OUT 1
AC Live to sub panel
OUT 2
AC Live to sub panel
ACN-OUT
AC Neutral to sub panel
AC Ground
AC Ground from main panel
AC Ground
AC Ground to sub panel
GP-IC-2000
#8 AWG
IN 1
AC Hot 1 from main panel
IN 2
AC Hot 2 from main panel
ACN-IN
AC Neutral from main panel
OUT 1
AC Live to sub panel
OUT 2
AC Live to sub panel
ACN-OUT
AC Neutral to sub panel
Sub Panel
Ground Bus Bar
Notes:
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
3.6.11 DISABLING THE NEUTRAL TO CHASSIS GROUND CONNECTION
Neutral Bus Bar
INSTALLATION Notes:
* All previous converter / charger wiring must be disconnected from the breaker panel. The GP-IC-2000 is now used for battery bank charging
The GP-IC-2000 has the automatic neutral to ground switching feature enabled as a factory default setting. In some installations this feature must be physically disabled by dis-connecting the neutral to chassis ground connection. Please consult your local code requirements to see if this feature must be physically disconnected. GFCI
Outlet
GFCI
Outlet
120 VAC 120 VAC
The chassis ground connection (used for AC and DC grounding) on the outside of the Inverter / Charger should still be connected to the systems Earth ground, even if the ground to neutral switching has been disabled.
WARNING: Disconnect all AC and DC power sources before working in the AC terminal wiring area.
AC Ground
AC Ground from main panel
AC Ground
AC Ground to sub panel
Ground Bus Bar
GP-IC-2000
Sub Panel
240 VAC
GFCI
Outlet
120 VAC
GFCI
Outlet
#6 AWG
Neutral Bus Bar
1. Remove the AC cover plate.
2. Locate the two ground terminals, to the left of these connectors is a Phillips screw. This screw must be un-screwed and removed from the compartment. Keep this screw in a safe place.
ACN-IN (White)
AC Neutral Input
3. Re-attach the AC cover plate.
2
AC Neutral to AC Source Ground
Transfer Relay Connected
AC Power Source
Ground GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
2
AC Neutral to Chassis
Ground Disconnected
IN1
IN2
ACN-IN
ACN-OUT (Black)
AC Neutral to sub panel
OUT2
ACN-OUT
IN1
IN2
ACN-IN
ACN-IN (White)
AC Neutral Input
OUT2
ACN-OUT
1
AC Neutral to AC Source Ground
Transfer Relay Disconnected
AC Power Source
Ground size : 55x36.5mm
GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
1
AC Neutral to Chassis
Ground Connected
ACN-OUT (Black)
AC Neutral to sub panel
Main Chassis
Earth Ground
Main Chassis (RV, Boat)
Earth Ground
AC Power Source
Ground
AC Power from Utility or
Generator
ACN-IN (White)
AC Neutral Input
AC Neutral to AC Source Ground
Transfer Relay Connected
GROUND
GP-IC-2000 Chassis Ground
GROUND
GP-IC-2000 Chassis Ground
Main Chassis
Earth Ground
Screw Removed x
AC Neutral to Chassis
Ground - Permanently
Disabled
ACN-OUT (Black)
AC Neutral to sub panel gpelectric.com | [page 35]
INSTALLATION
3.6.12 GROUNDING ON BOATS
If you are installing the GP-IC-2000 on a boat there are some specific guidelines/standards to follow. The Inverter / Charger must be installed adhering to the standards of the AYBC (American Boat and Yacht Council). Some guidelines are outlined below but these notes do not replace the full guidelines detailed in the AYBC standard, always install the GP-IC-2000 using the AYBC standard as the primary reference.
Safe AC and DC Ground Connection
As detailed in the last section when the AC power source is being supplied by shore power (Marina) the on board neutral must be connected to the safety ground on the dock. This feature is automatically taken care of by the GP-IC-2000. When the AC power source is being supplied by the Inverter (battery bank) the on board neutral must be connected to the common boat ground.
The DC ground terminal must also be connected to the common boat ground. This ensures that both the AC and DC ground are connected to one common boat ground.
Corrosion
The GP-IC-2000 AC and DC terminals must be connected to the common boat ground to provide an important safety feature.
This ground connection can introduce the risk of galvanic corrosion and/or electrolysis of the boats underwater metallic hardware.
A galvanic isolator or an on board isolation transformer can be used to prevent galvanic corrosion.
[page 36] | gpelectric.com
INSTALLATION
3.7 FINAL INSPECTION
1. Verify all cables / conduit runs are secured with zip ties or other non-conductive cable clamps to prevent damage from vibration.
2. Ensure all cables that pass through walls, bulkheads or any other openings are protected against abrasion by using strain reliefs and/or grommets.
3. Check all AC, DC and ground connections are securely tightened, and if required covered with suitable anti-seizing grease.
4. Check the AC terminal connection cover plate has been securely re-attached.
5. Check all connections are secure in the main and sub panels - replace all covers.
6. If required by code, have the installation inspected by an electrical inspector.
3.8 TESTING THE INSTALLATION
1. Apply battery power to the inverter by engaging the fuse, switching the breaker or switching the battery disconnect switch to the ON position. The GP-IC-2000 will remain off.
2. Disconnect all AC loads from the breaker panel by switching the main on/off breaker to OFF.
3. Press the ON/OFF button. Verify the inverters status indicator is solid green (ON).
4. Connect a 25W light bulb to the inverter output and verify it comes on and shines normally.
5. Press and release the ON/OFF button to turn the Inverter / Charger off, the bulb will turn off and the status indicator will turn off.
6. Apply AC shore power (utility or generator) to the GP-IC-2000. After around 10 seconds the Inverter / Charger will click and the incoming power will be passed through and the light bulb will turn on. The status indicator will be green.
7. The inverter is currently OFF because the AC shore power is powering the light bulb. Press and release the ON/OFF switch on the GP-IC-2000 to turn on the Inverter.
8. Disconnect the AC shore power, the light bulb should remain on and is now being powered by the Inverter (battery bank).
3.9 WARNING LABELS
When an Inverter / Charger is installed in a building the NEC requires a label or plaque to be provided. This label / plaque is required to be easily visible and to provide information that informs users of the location of all electrical system disconnects.
Buildings with stand alone power systems (solar, generator) and utility power must have a permanent plaque or directory providing the location of both system disconnects.
An Inverter warning label should be installed in a clearly visible location on the breaker panel that is being powered by the GP-
IC-2000. This label is used because it might be falsely assumed that the panel is no longer “live” after the AC Shore Power is turned off, when power may actually still be available from the Inverter (battery bank) powering the sub panel.
gpelectric.com | [page 37]
®
Temperature Sensor
4. OPERATION
4.1 GENERAL OPERATING NOTES
ON / OFF SWITCH
When the GP-IC-2000 is first connected to the battery bank the ON/OFF switch must be lightly pressed to turn the Inverter ON.
Once the Inverter has been turned ON, pressing the ON/OFF switch turns the Inverter on and off.
WARNING: The ON/OFF switch does not turn the battery charger or remove AC pass through mode. If AC power is connected to the AC Input, this AC power will also be available on the AC output and is not controlled by the Power
ON/OFF switch.
INV./CHR. MODE LED INDICATOR
LED Status
Solid Green
Green Blink
Status
Inverting Mode
Charging Mode
REMOTE
ON/OFF
STATUS
AC INPUT
STATUS LED INDICATOR
LED Status Status Recovery Point
Green
Red Slow Blink
Red Fast Blink
Orange
Normal
Over Voltage Protection
(Input DC voltage over specification)
Under Voltage Protection
(Input DC voltage under specification)
Over Load Protection
Short Circuit Protection
INV. AC
OUTPUT
14.5 VDC
12.5 VDC
NEG
-
Orange Slow Blink Over Temperature Protection
Orange Fast Blink Under Temperature Protection
POS +
The GP-IC-2000 has two basic operating modes: Inverting and AC power pass through. Within these two modes the GP-IC-2000 functions differently depending on the load power and shore power specifications/requirements. These different operating modes are outlined over the following pages.
SEARCH MODE
When the Inverter in the GP-IC-2000 is turned ON, the automatic search function is enabled. This feature is used to conserve battery power when no AC power is required (no appliances being used).
In search mode the GP-IC-2000 continually scans the AC output looking for an AC load (appliance turned on). When an AC appliance is turned on, an AC load is registered at the AC output and the Inverter switches ON and supplies AC power (from the battery bank) to the appliance.
The AC load required to switch the Inverter ON is set to 5W as a factory default value. The search feature can be turned OFF and can be adjusted between 5 and 50W - to adjust these values the GP-IC-Remote must be used (this can be purchased separately from Go Power!).
[page 38] | gpelectric.com
4.9” (124mm)
.28” (7mm)
13.6” (346mm)
2” (51mm) 4.9” (124mm)
.51” (13mm)
12.6”
(321mm)
13.7”
14.9”
(349mm)
(378mm)
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
8.1”
(205mm)
AC INPUT
REMOTE
ON/OFF
STATUS
INV. AC
OUTPUT
NEG
-
POS +
CAUTION:
• TO PREVENT FIRE, DO NOT COVER OR OBSTRUCT VENTILATION OPENINGS. DO NOT MOUNT IN ZERO-CLEARANCE
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
MISE EN GARDE:
• POUR PRÉVENIR LES RISQUES D’INCENDIE, NE PAS COUVRIR NI OBSTRUER LES OUVERTURES D’AÉRATION. NE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
CONTENANT CHACUNE 6 ou 12 CELLULES.
WARNING:
• THIS EQUIPMENT EMPLOYS COMPONENTS THAT TEND TO PRODUCE ARCS OR SPARKS. TO PREVENT FIRE OR
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
AVERTISSEMENT:
• CET ÉQUIPEMENT EMPLOIE DES COMPOSANTS POUVANT PROVOQUER DES ARCS ÉLECTRIQUES OU DES
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
DANGER:
• TO REDUCE THE RISK OF EXPLOSION - DO NOT INSTALL IN MACHINERY SPACE OR AREA IN WHICH IGNITION
- PROTECTED EQUIPMENT IS REQUIRED.
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
MACHINE OU UNE ZONE CONTENANT UN ALLUMAGE — L’ÉQUIPEMENT PROTÉGÉ EST EXIGÉ
• POUR RÉDUIRE LE RISQUE D’EXPLOSION, NE PAS INSTALLER LE PRODUIT DANS UN COMPARTIMENT
- PROTECTED EQUIPMENT IS REQUIRED.
DANGER:
TESTER AVANT DE TOUCHER. • PRÉVU POUR UNE UTILISATION CONTINUE.
CONNECTÉS À CE PRODUIT. • RISQUE DE DÉCHARGE ÉLECTRIQUE, PUITS THERMIQUES NON MIS À LA TERRE,
PRODUIT. LES AUTRES TYPES PEUVENT NE PAS FONCTIONNER CORRECTEMENT LORSQU’ILS SONT
MASSE OU LE COUPE-CIRCUIT INDIQUÉS DANS LE MANUEL D’INSTALLATION ET D’UTILISATION FOURNI AVEC CE
DÉCHARGE ÉLECTRIQUE. UTILISER UNIQUEMENT LE RÉCEPTACLE D’INTERRUPTEUR DE CIRCUIT DE MISE À LA
DANS UN COMPARTIMENT CONTENANT DES PILES OU DES MATÉRIAUX INFLAMMABLES. • RISQUE DE
ÉTINCELLES. POUR PRÉVENIR LES RISQUES D’INCENDIE OU D’EXPLOSION, NE PAS INSTALLER LE PRODUIT
AVERTISSEMENT:
HEATSINKS ARE NOT BONDED TO GROUND, TEST BEFORE TOUCHING. • INTENDED FOR CONTINUOUS DUTY.
TYPES MAY FAIL TO OPERATE PROPERLY WHEN CONNECTED TO THIS UNIT. • RISK OF ELECTRIC SHOCK,
BREAKER SPECIFIED IN THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THIS UNIT. OTHER
OF ELECTRIC SHOCK. USE ONLY THE GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLE OR CIRCUIT
EXPLOSION, DO NOT INSTALL IN COMPARTMENTS CONTAINING BATTERIES OR FLAMMABLE MATERIALS. • RISK
WARNING:
CONTENANT CHACUNE 6 ou 12 CELLULES.
PROTECTION INTÉGRALE CONTRE LA SURCHARGE. • NE CHARGER QUE DES PILES AU PLOMB RECHARGEABLES
DE LA POLARITÉ DES PILES DOIT ÊTRE CORRECTE, AU RISQUE D’ENDOMMAG ER LE PRODUIT. • FOURNI AVEC UNE
RISQUES DE DÉCHARGE ÉLECTRIQUE, NE PAS L’EXPOSER À LA PLUIE OU À LA PULVÉRISATION. • L’ORIENTATION
D’ÊTRE RÉPARÉE PAR L’UTILISATEUR. CONFIEZ L’ENTRETIEN À DU PERSONNEL QUALIFIÉ. • POUR RÉDUIRE LES
RISQUE DE DÉCHARGE ÉLECTRIQUE, NE PAS RETIRER LE COUVERCLE, NE CONTIENT AUCUNE PIÈCE SUSCEPTIBLE
PAS MONTER LE PRODUIT DANS UN COMPARTIMENT SANS AUCUN DÉGAGEMENT. RISQUE DE SURCHAUFFE. •
MISE EN GARDE:
RECHARGEABLE BATTERIES, EACH 6 or 12 CELLS IN THE BATTERY.
RESULT. • PROVIDED WITH INTEGRAL PROTECTION AGAINST OVERLOADS. • CHARGE ONLY LEAD ACID TYPE
ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN OR SPRAY. • BATTERY POLARITY MUST BE CORRECT OR DAMAGE WILL
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. • TO REDUCE RISK OF
COMPARTMENT. OVERHEATING MAY RESULT. • RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, NO USER
CAUTION:
REMOTE
Main Panel
Negative Bus Bar
Equipment Grounding Bus Bar
Earth Ground (RV, Boat Ground)
Sub Panel
120 VAC
240 VAC
120 VAC
ON
OFF
GP-IC-2000
DC Panel
Battery Disconnect Switch
(not required if circuit breaker is used)
Fuse or Circuit Breaker
Battery Bank
OPERATION
BATTERY CHARGER SPECIFICATIONS
The GP-IC-2000 is equipped with a PFC (Power Factor Corrected) and PI (Proportional Integral) multistage battery charger.
These 2 features maximize the real power from AC Shore Power. The multistage battery charger can use up to four different charging stages to help monitor and keep the batteries healthy.
Bulk Charging: This is the initial stage of charging. While bulk charging, the charger supplies the battery bank with controlled constant current. The charger will remain in bulk charge until the absorption charge voltage is achieved.
Absorb Charging: This is the second charging state and begins after the absorb voltage has been reached. Absorb charging provides the batteries with a constant voltage and reduces the DC charging current in order to maintain the absorb voltage setting.
The factory default setting for absorb charging is 2 hours. After 2 hours of absorb charging the charger switches to final charge.
Final (Float) Charging: The third charging stage occurs at the end of absorb charging time. While final charging, the charge voltage is reduced to the final charge voltage set point. In this stage, the batteries are kept fully charged and ready if needed by the Inverter. The final (float) charging stage reduces battery gassing, minimizes watering requirements and ensures the batteries are maintained at optimum capacity.
BULK ABSORPTION
Battery Charging Voltage
FINAL (FLOAT)
Battery Charging Current
Time
Equalization Charging: The EQ charging is used to stir up stratified electrolyte and to reverse any battery plate sulfation that may have occurred. The EQ charging mode can only be used with the GP-IC-Remote, sold separately by Go Power!.
BATTERY CHARGING SET POINTS
LED Status
Absorption
Voltage
Float
Voltage
Equalization
Voltage
Gel
14.1 VDC
13.6 VDC
Flooded
14.6 VDC
13.4 VDC
15.5 VDC
AGM 1
14.3 VDC
13.1 VDC
15.5 VDC
AGM 2
14.5 VDC
13.5 VDC
Custom
12-16 VDC
12-16 VDC
D gpelectric.com | [page 39]
A
ON
OFF
C
B
Utility Power
120/240 VAC
Generator Power
120 / 240 VAC
1800W
Main Panel
1
Charging Mode
* No load power required (fridge, air conditioner, etc)
(1) IC-2000 operates in Battery Charging Mode
(2) 1800W (15 AAC x 120 VAC) of shore power used to charge the batteries, this equates to ≈ 100 ADC / hour
(with charger peak efficiency and max voltage charge set points)
ON
OFF
Sub Panel
2
Batteries Charging
Up to 100 ADC / Hour
OPERATION
4.2 AC POWER PASS THROUGH MODE
In AC power pass through mode;
• Shore power (utility or generator) is connected.
• The power required by the appliances (fridge, TV, charger) is 3600W (30AAC x 120VAC) -
1.
• Shore power is powering all the appliances (3600W) -
2.
• Batteries are not being charged.
Utility Power
120/240 VAC
Generator Power
120/240 VAC
3600W
1
Sub Panel
3600 Watts
Load Power Required
3600 Watts (30A x 120V)
Shore Power Only
120 VAC
240 VAC
120 VAC
3600W
Main Panel
2
ON
OFF
AC Power Pass Through Mode
* IC-2000 operates in AC Pass Through Mode
(1) 3600W of Load Power required (fridge, air conditioner, etc)
(2) 3600W of shore or generator power used to supply all the load power required
* Batteries are not being charged, all shore power is used for load power
Utility Power
120/240 VAC
120 VAC
240 VAC
120 VAC
[page 40] | gpelectric.com
Generator Power
120 / 240 VAC
6000W
Main Panel
2
Power Sharing Mode
(1) 4200W of Load power required (fridge, air conditioner, etc)
* IC-2000 operates in AC Pass Through & Battery Charging Mode
(2) 6000W of shore power available
(3) 4200W used to supply the load power required
(4) The remaining 1800W (15AAC x 120VAC) of shore power is used to charge batteries at 100 Amps DC / hour
Main Panel
Inverting Mode
(1) 2000W of load power required (fridge, air conditioner, etc)
* IC-2000 operates in Inverting Mode
(2) Batteries are supplying all the load power required
2000W = ≈ 186 ADC x 12VDC x 0.9 (Efficiency)
* No Shore or Generator Power
Utility Power
120/240 VAC
Generator Power
120/240 VAC
4200W
3
1
Sub Panel
4200 Watts
Load Power Required
4200 Watts (35AAC x 120VAC)
Shore Power Only
120 VAC
240 VAC
120 VAC
ON
OFF
4
Batteries Charging
Batteries Charging
Up to 100 ADC / Hour
2400W
Main Panel
2
Generator Mode
(1) 3600W of load power required (Fridge, Air Conditioner, etc)
* IC-2000 operates in AC Pass Through & Inverting Mode
(2) 2400W (20AAC x 120VAC) of shore power is used to supply part of the load power required
(3) Batteries are supplying the remaining load power required =
1200W
2000W
ON
OFF
1
Sub Panel
2000 Watts
Load Power Required
2000W
Battery Bank
120 VAC
240 VAC
120 VAC
2
≈ 186 Amps DC / hour
1200W
2400W
1
Sub Panel
3600 Watts
Load Power Required
2400W
Shore
1200W
Battery Bank
120 VAC
240 VAC
120 VAC
ON
OFF
3
Battery Dis - Charging
Utility Power
120/240 VAC
Generator Power
120/240 VAC
3600W
OPERATION
4.3 CHARGING MODE
In charging mode;
• Shore power (utility or generator) is connected and supplying 15AAC (1800W: 15AAC x 120VAC ) -
1.
• No power is required by the appliances (fridge, TV, charger).
• Batteries are being charged up to 100 Amps DC per hour -
2.
Main Panel
AC Power Pass Through Mode
* IC-2000 operates in AC Pass Through Mode
(1) 3600W of Load Power required (fridge, air conditioner, etc)
(2) 3600W of shore or generator power used to supply all the load power required
* Batteries are not being charged, all shore power is used for load power
2
Utility Power
120/240 VAC
Generator Power
120 / 240 VAC
Utility Power
120/240 VAC
Generator Power
120 / 240 VAC
Sub Panel
120 VAC
240 VAC
120 VAC
1800W
Main Panel
1
Charging Mode
* No load power required (fridge, air conditioner, etc)
(1) IC-2000 operates in Battery Charging Mode
(2) 1800W (15 AAC x 120 VAC) of shore power used to charge the batteries, this equates to ≈ 100 ADC / hour
(with charger peak efficiency and max voltage charge set points)
ON
OFF
2
Batteries Charging
Up to 100 ADC / Hour
6000W
Main Panel
2
Power Sharing Mode
(1) 4200W of Load power required (fridge, air conditioner, etc)
* IC-2000 operates in AC Pass Through & Battery Charging Mode
(2) 6000W of shore power available
(3) 4200W used to supply the load power required
(4) The remaining 1800W (15AAC x 120VAC) of shore power is used to charge batteries at 100 Amps DC / hour
3600W
1
Sub Panel
3600 Watts
Load Power Required
3600 Watts (30A x 120V)
Shore Power Only
120 VAC
240 VAC
120 VAC
ON
OFF
Main Panel
Inverting Mode
(1) 2000W of load power required (fridge, air conditioner, etc)
* IC-2000 operates in Inverting Mode
(2) Batteries are supplying all the load power required
2000W = ≈ 186 ADC x 12VDC x 0.9 (Efficiency)
* No Shore or Generator Power
Utility Power
120/240 VAC
Generator Power
120/240 VAC
4200W
3
1
Sub Panel
4200 Watts
Load Power Required
4200 Watts (35AAC x 120VAC)
Shore Power Only
120 VAC
240 VAC
120 VAC
ON
OFF
4
Batteries Charging
Batteries Charging
Up to 100 ADC / Hour
2400W
Main Panel
2
Generator Mode
(1) 3600W of load power required (Fridge, Air Conditioner, etc)
* IC-2000 operates in AC Pass Through & Inverting Mode
(2) 2400W (20AAC x 120VAC) of shore power is used to supply part of the load power required
(3) Batteries are supplying the remaining load power required =
1200W
2000W
ON
OFF
1
Sub Panel
2000 Watts
Load Power Required
2000W
Battery Bank
120 VAC
240 VAC
120 VAC
2
≈ 186 Amps DC / hour
1200W
2400W
1
Sub Panel
3600 Watts
Load Power Required
2400W
Shore
1200W
Battery Bank
120 VAC
240 VAC
120 VAC
ON
OFF
3
Battery Dis - Charging gpelectric.com | [page 41]
Utility Power
120/240 VAC
Generator Power
120 / 240 VAC
1800W
Main Panel
1
Charging Mode
* No load power required (fridge, air conditioner, etc)
(1) IC-2000 operates in Battery Charging Mode
(2) 1800W (15 AAC x 120 VAC) of shore power used to charge the batteries, this equates to ≈ 100 ADC / hour
(with charger peak efficiency and max voltage charge set points)
ON
OFF
Sub Panel
120 VAC
240 VAC
120 VAC
2
Batteries Charging
Up to 100 ADC / Hour
Utility Power
120/240 VAC
Generator Power
120/240 VAC
1
3600 Watts
Load Power Required
3600 Watts (30A x 120V)
Shore Power Only
120 VAC
3600W
240 VAC
120 VAC
Sub Panel
3600W
OPERATION
Main Panel
4.4 POWER SHARING MODE
2
ON
OFF
In power sharing mode;
• The power required by the appliances (fridge, TV, charger) is 4200W (35AAC x 120VAC) -
1.
• Shore power (Utility or Generator) is connected and supplying 6000W (50AAC x 120VAC) -
2.
* IC-2000 operates in AC Pass Through Mode
• 4200W of AC power is passed through the Inverter / Charger to power the appliances -
3.
(2) 3600W of shore or generator power used to supply all the load hour -
4.
1800W (15AAC x 120VAC) is used for battery bank charging, up to 100 Amps DC per
Utility Power
120/240 VAC
Generator Power
120 / 240 VAC
6000W
Main Panel
2
Power Sharing Mode
(1) 4200W of Load power required (fridge, air conditioner, etc)
* IC-2000 operates in AC Pass Through & Battery Charging Mode
(2) 6000W of shore power available
(3) 4200W used to supply the load power required
(4) The remaining 1800W (15AAC x 120VAC) of shore power is used to charge batteries at 100 Amps DC / hour
Main Panel
Inverting Mode
(1) 2000W of load power required (fridge, air conditioner, etc)
* IC-2000 operates in Inverting Mode
(2) Batteries are supplying all the load power required
2000W = ≈ 186 ADC x 12VDC x 0.9 (Efficiency)
* No Shore or Generator Power
Utility Power
120/240 VAC
Generator Power
120/240 VAC
4200W
3
1
Sub Panel
4200 Watts
Load Power Required
4200 Watts (35AAC x 120VAC)
Shore Power Only
120 VAC
240 VAC
120 VAC
ON
OFF
4
Batteries Charging
Batteries Charging
Up to 100 ADC / Hour
2400W
Main Panel
2
Generator Mode
(1) 3600W of load power required (Fridge, Air Conditioner, etc)
* IC-2000 operates in AC Pass Through & Inverting Mode
(2) 2400W (20AAC x 120VAC) of shore power is used to supply part of the load power required
(3) Batteries are supplying the remaining load power required =
1200W
2000W
ON
OFF
1
Sub Panel
2000 Watts
Load Power Required
2000W
Battery Bank
120 VAC
240 VAC
120 VAC
2
≈ 186 Amps DC / hour
1200W
2400W
1
Sub Panel
3600 Watts
Load Power Required
2400W
Shore
1200W
Battery Bank
120 VAC
240 VAC
120 VAC
ON
OFF
3
Battery Dis - Charging
[page 42] | gpelectric.com
Utility Power
120/240 VAC
Generator Power
120 / 240 VAC
1800W
Main Panel
1
Charging Mode
* No load power required (fridge, air conditioner, etc)
(1) IC-2000 operates in Battery Charging Mode
(2) 1800W (15 AAC x 120 VAC) of shore power used to charge the batteries, this equates to ≈ 100 ADC / hour
(with charger peak efficiency and max voltage charge set points)
Utility Power
120/240 VAC
Generator Power
120/240 VAC
Main Panel
3600W
2
AC Power Pass Through Mode
* IC-2000 operates in AC Pass Through Mode
(1) 3600W of Load Power required (fridge, air conditioner, etc)
(2) 3600W of shore or generator power used to supply all the load power required
* Batteries are not being charged, all shore power is used for load power
Utility Power
120/240 VAC
Generator Power
120 / 240 VAC
Sub Panel
120 VAC
240 VAC
120 VAC
ON
OFF
2
Batteries Charging
Up to 100 ADC / Hour
6000W
Main Panel
2
Power Sharing Mode
(1) 4200W of Load power required (fridge, air conditioner, etc)
* IC-2000 operates in AC Pass Through & Battery Charging Mode
(2) 6000W of shore power available
(3) 4200W used to supply the load power required
(4) The remaining 1800W (15AAC x 120VAC) of shore power is used to charge batteries at 100 Amps DC / hour
3600W
1
Sub Panel
3600 Watts
Load Power Required
3600 Watts (30A x 120V)
Shore Power Only
120 VAC
240 VAC
120 VAC
ON
OFF
2000W
1
Sub Panel
2000 Watts
Load Power Required
2000W
Battery Bank
120 VAC
240 VAC
120 VAC
OPERATION
Main Panel
4.5 GENERATOR MODE
ON
OFF
In generator mode;
2
• The power required by the appliances (fridge, TV, outlets) is 3600W (30AAC x 120VAC) -
Inverting Mode
1.
• Shore power (utility or generator) is connected and supplying 2400W (20AAC x 120VAC) -
2.
* IC-2000 operates in Inverting Mode required to power the appliances -
2000W = ≈ 186 ADC x 12VDC x 0.9 (Efficiency)
3.
≈ 186 Amps DC / hour
• The inverter automatically switches on and supplies the remaining 1200W (10AAC x 120VAC) of AC power
* No Shore or Generator Power
4200W
ON
OFF
3
1
Sub Panel
4200 Watts
Load Power Required
4200 Watts (35AAC x 120VAC)
Shore Power Only
120 VAC
240 VAC
120 VAC
4
Batteries Charging
Batteries Charging
Up to 100 ADC / Hour
Utility Power
120/240 VAC
Generator Power
120/240 VAC
2400W
Main Panel
2
Generator Mode
(1) 3600W of load power required (Fridge, Air Conditioner, etc)
* IC-2000 operates in AC Pass Through & Inverting Mode
(2) 2400W (20AAC x 120VAC) of shore power is used to supply part of the load power required
(3) Batteries are supplying the remaining load power required =
1200W
1200W
2400W
1
Sub Panel
3600 Watts
Load Power Required
2400W
Shore
1200W
Battery Bank
120 VAC
240 VAC
120 VAC
ON
OFF
3
Battery Dis - Charging gpelectric.com | [page 43]
Utility Power
120/240 VAC
Generator Power
120 / 240 VAC
1800W
Main Panel
1
Charging Mode
* No load power required (fridge, air conditioner, etc)
(1) IC-2000 operates in Battery Charging Mode
(2) 1800W (15 AAC x 120 VAC) of shore power used to charge the batteries, this equates to ≈ 100 ADC / hour
(with charger peak efficiency and max voltage charge set points)
OPERATION
4.6 INVERTING MODE
In inverting mode;
• The load power required by the appliances (fridge, TV, charger) is 2000W (16.7AAC x 120VAC) -
1.
• The inverter supplies the 2000W (186 ADC x 12VDC x 0.9) of AC power required to power the appliances -
2.
• Shore power (utility or generator) is not connected.
Utility Power
120/240 VAC
Generator Power
120/240 VAC
Main Panel
3600W
2
AC Power Pass Through Mode
* IC-2000 operates in AC Pass Through Mode
(1) 3600W of Load Power required (fridge, air conditioner, etc)
(2) 3600W of shore or generator power used to supply all the load power required
* Batteries are not being charged, all shore power is used for load power
Utility Power
120/240 VAC
Generator Power
120 / 240 VAC
Sub Panel
120 VAC
240 VAC
120 VAC
ON
OFF
2
Batteries Charging
Up to 100 ADC / Hour
6000W
Main Panel
2
Power Sharing Mode
(1) 4200W of Load power required (fridge, air conditioner, etc)
* IC-2000 operates in AC Pass Through & Battery Charging Mode
(2) 6000W of shore power available
(3) 4200W used to supply the load power required
(4) The remaining 1800W (15AAC x 120VAC) of shore power is used to charge batteries at 100 Amps DC / hour
3600W
1
Sub Panel
3600 Watts
Load Power Required
3600 Watts (30A x 120V)
Shore Power Only
120 VAC
240 VAC
120 VAC
ON
OFF
Main Panel
Inverting Mode
(1) 2000W of load power required (fridge, air conditioner, etc)
* IC-2000 operates in Inverting Mode
(2) Batteries are supplying all the load power required
2000W = ≈ 186 ADC x 12VDC x 0.9 (Efficiency)
* No Shore or Generator Power
Utility Power
120/240 VAC
Generator Power
120/240 VAC
4200W
3
1
Sub Panel
4200 Watts
Load Power Required
4200 Watts (35AAC x 120VAC)
Shore Power Only
120 VAC
240 VAC
120 VAC
[page 44] | gpelectric.com
2400W
ON
OFF
Main Panel
2
4
Batteries Charging
Batteries Charging
Up to 100 ADC / Hour
Generator Mode
(1) 3600W of load power required (Fridge, Air Conditioner, etc)
* IC-2000 operates in AC Pass Through & Inverting Mode
(2) 2400W (20AAC x 120VAC) of shore power is used to supply part of the load power required
(3) Batteries are supplying the remaining load power required =
1200W
2000W
ON
OFF
1
Sub Panel
2000 Watts
Load Power Required
2000W
Battery Bank
120 VAC
240 VAC
120 VAC
2
≈ 186 Amps DC / hour
1200W
2400W
1
Sub Panel
3600 Watts
Load Power Required
2400W
Shore
1200W
Battery Bank
120 VAC
240 VAC
120 VAC
ON
OFF
3
Battery Dis - Charging
OPERATION
4.7 BATTERY TEMPERATURE SENSOR (BTS) OPERATION
The GP-IC-2000 is delivered with a battery temperature sensor. By installing this sensor the charge voltages are automatically adapted for deviating temperature. With a BTS installed , if the temperature around the BTS is below 20°C the absorb and float charge voltage increases. If the temperature around the BTS is above 20°C, the absorb and float charge voltage decreases. The graph below details how much the charge voltage changes (increases or decreases) depending on the temperature reading of the BTS.
4.8 FACTORY DEFAULT VALUES
The GP-IC-2000 uses default values for the following adjustable settings;
Adjustable Settings
Shore Input
Low Battery Cut Out
VAC Dropout
Max Charge Time
Battery Type
Charge Rate
ABS Charge Time
Default Values
30 Amps (AC)
10.5 VDC
85 VAC
12 Hours
AGM 1
80%
2 Hours
These settings are only adjustable with the GP-IC-2000 remote, which can be purchased separately from Go Power!. For detailed information on these settings please refer to the remote control manual. The remote also displays the real time Inverter
/ Chargers operating status and allows the user to run the equalize charging profile on the battery bank.
gpelectric.com | [page 45]
OPERATION
4.9 GP-IC-2000 FAULT CONDITIONS
The GP-IC-2000 is protected against fault conditions and in normal use it will be rare to see any. If a fault condition does occur, the GP-IC-2000 will shut down as a safety measure to protect itself, the battery bank and the AC loads. The following fault conditions could be the cause of Inverter / Charger shut down;
LOW BATTERY The GP-IC-2000 will shut off whenever the battery bank voltage falls to the LBCO (Low Battery Cut Out) level to protect the batteries from being over-discharged. When the Inverter / Charger has reached the LBCO and turned off, the unit will automatically restart when AC shore power is supplied to the AC Input and the battery bank voltage rises above the LBCI
(Low Battery Cut In) 12.5 VDC level
HIGH BATTERY The GP-IC-2000 will shut off whenever the battery bank voltage approaches the HBCO (High Battery Cut
Out) level the Inverter / Charger will automatically shut down to prevent un-regulated AC output voltage being supplied to the AC loads. The unit will automatically restart when the battery bank voltage falls below the HBCI (High Battery Cut In) 14.5 VDC level
OVER TEMPERATURE - The GP-IC-2000 monitors the temperature of several key components within the Inverter / Charger - if these components begin to exceed their safe operating temperature level, the unit will shutdown to protect itself. The unit will automatically restart after the unit cools down.
OVERLOAD - When the GP-IC-2000 is in Inverting or AC pass through mode, the Inverter / Charger monitors the current levels, in the event of a short circuit or an overload condition the unit will shut down. To start operating after this fault, the Inverter /
Charger must be turned on using the on/off switch on the unit or remote control once the AC loads are reduced / removed.
INTERNAL FAULT - The GP-IC-2000 continues to monitor several internal components, if a condition occurs that does not allow normal operation the Inverter / Charger will shut down to protect itself, the battery bank and the AC loads. To start operating after this fault, the Inverter / Charger must be turned on using the on/off switch on the unit or remote control
4.10 MAINTENANCE AND TROUBLESHOOTING
The GP-IC-2000 is designed to be service-free, even though there are no user serviceable parts, it is recommended that every
6 months you perform the following maintenance steps to ensure optimum performance and extend the life of your batteries.
• Visually inspect the batteries for cracks, leaks or swelling - replace if necessary.
• Use baking soda to clean and remove any electrolyte spills or buildups.
• Check and tighten all battery terminal connections.
• Check and fill battery water levels in flooded lead acid batteries.
• Check individual battery voltages (load test those that have a voltage difference of more than 0.3 VDC from each other) replace if necessary.
• Check the Inverter / Chargers ventilation vents - clean if necessary.
• Visually inspect all cables in both the DC and AC systems - check for wear/abrasion - replace if necessary and ensure strain reliefs and cable protection is installed to prevent future damage.
• Check and tighten the Inverter / Chargers AC terminal block connections.
• Check the ground connections are secure on the Inverter / Charger, Battery Bank, Main / Sub Panels and the
Earth Ground on the RV, Boat.
• Check the battery sensor is still securely attached to the battery bank.
[page 46] | gpelectric.com
OPERATION
Symptom
No output power.
Inverter LED is
OFF
Possible Cause
Inverter is switched OFF
Battery voltage is too low. The battery voltage level has dropped below the Low Battery Cut
Off (LBCO)
Battery voltage is too high. The Inverter automatically resets and resumes operation when the battery voltage level has dropped below the HBCI set point.
Over-temperature condition: The internal temperature of the Inverter has risen above acceptable limits; caused by loads too great for the Inverter to operate continuously, or by lack of ventilation to the Inverter.
AC over-load condition: The Inverter has turned off because the connected loads are larger than the Inverter / Chargers output capacity, or the output wires are shorted.
Internal fault
No output power.
Inverter LED is
ON
Low output or surge power.
Inverter LED is
ON
Low charging rate when connected to AC Utility
Power
Unit is in search mode, which means load is too small for search mode circuit detection
Loose or corroded battery cables
Low batteries
Loose AC output connections
Battery cables are the wrong length or gauge
Charge rate set too low
Low AC voltage (< 90 VAC)
Recommended Solution
Turn the Inverter ON
Check all connections for a break in the circuit:
Fuses, Circuit breakers, Cable terminals. The
Batteries need charging.
This condition usually only occurs when an additional charging source (solar panels) is used to charge the batteries. Remove or disconnect the additional charging source, so the voltage of the battery bank can drop.
Reduce the AC loads (appliances) that are operating.
Check ventilation around the Inverter, ensure all ventilation openings are clear and un-obstructed
To clear this fault, an Inverter reset is required.
Remove DC power to the Inverter, or press and hold down the ON / OFF switch for 15 seconds.
Turn on a load greater than 5 watts to bring Inverter
/ Charger to full output power, or turn off search function with the GP-IC-2000 remote
Clean and tighten all cables
Recharge or replace batteries
Tighten AC output connections
Verify recommended cable lengths and gauges from the manual. Replace cables as necessary
Adjust charge rate or Shore settings on remote
Check AC input wiring
Reduce the load, increase the generator’s RPMs
Low charging rate when connected generator
Generator output is too low to power both load and charger
Charger does not charge
Loose or corroded battery cables
Defective batteries
Wrong charger settings
Wrong AC input voltage
Adjust charge rate or Shore settings on remote
Clean and tighten battery cables
Replace batteries
Adjust the charger settings
Verify proper AC input voltage gpelectric.com | [page 47]
Electrical
Inverter
Mode
Input
Output
Charger
Mode
Charger
Equalization
Bypass Relay
Operating Temperature
Range
Operating Humidity Range
Ground Relay
Mechanical
Specification
Safety and EMC
5. SPECIFICATIONS
Specification Item GP-IC-2000
Nominal Voltage
Absolute Max. DC Input
HBCO / HBCI
LBCO / LBCI
Input Voltage Range
Input Over-Voltage Protection
Input Under-Voltage Protection
Max DC Input Current
No Load Power Consumption
Stand-By Power Consumption
Continuous Output Power
Surge Power
5 sec
30 sec
5 min
30 min
12 VDC
25 VDC
17 VDC ±0.3V
9.0 VDC ±0.3V
9 - 17 VDC ±0.3V
16.5 - 17 VDC
9 - 10.5 VDC
267 ADC
25W
<5W
2000W
3400W
3200W
2900W
2300W
60 Hz Frequency
Output Voltage
Max Efficiency
Short Circuit Protection
Output Waveform
Battery Temperature Protection
AC Input Voltage Range
AC Input Frequency Range
AC Input Current Range
AC Nominal Current
Charger Peak Efficiency
120 VAC +/-5%( ≦ Continuous Power)
>90%
Yes
Pure Sine Wave (THD <5%)
Yes
80 - 140 VAC±5%
47 - 63 Hz
5 - 50A
15A
85%
Power Factor Correction
Charging Current Range
Battery Temperature Compensation
Four State Charging
Max Output Voltage
Max Output Current
>0.97 (50% Load)
0 - 100A
25 mV per °C
Bulk, Absorb, Float, Equalize
16 VDC
10A
Relay Specification
Full Load
Power De - Rating
Storage
50 AAC (per leg)
-20°C to 40°C
60W per °C from 41°C - 60°C
-30°C to 70°C
Over temperature protection Transformer, MOSFETs, Battery
0-95% Non-condensing
Default is Open (AC Pass Through Mode)
Size (WxHxD)
Net Weight
12.6” x 6.9” x 13.7”
(321mm x 175mm x 349mm)
17.6 Kg (38.71 lbs)
Safety Standards
EMC Standards
UL 458, UL 1741, CSA 22.2 No.107.1-01
FCC Class B
[page 48] | gpelectric.com
6. WARRANTY RETURN PROCEDURE
The Go Power! warranty is valid against defects in materials and workmanship for the specific product warranty period. It is not valid against defects resulting from, but not limited to:
• Misuse and/or abuse, neglect or accident.
• Exceeding the unit’s design limits.
• Improper installation, including, but not limited to, improper environmental protection and improper hook-up.
• Acts of God, including lightning, floods, earthquakes, fire, and high winds.
• Damage in handling, including damage encountered during shipment.
A warranty shall be considered void if the warranted product is in any way opened or altered. The warranty will be void if any eyelet, rivets, or other fasteners used to seal the unit are removed or altered, or if the unit’s serial number is in any way removed, altered, replaced, defaced, or rendered illegible.
Warranty Return Procedure
Before contacting Go Power!’s customer service department, please read the “frequently asked questions” section of our website to troubleshoot the problem. If trouble persists:
1. Call your Go Power!™ Technical Support team (1-866-247-6527) or
2. Return defective product to place of purchase.
Unless approved by Go Power! Management, all product shipped collect to Go Power! will be refused. Test items or items that are not under warranty, or units that are not defective, will be charged a minimum bench charge of ($50.00 US) plus taxes and shipping. A 15% restocking charge will be applied on goods returned and accepted as “new” stock.
An RMA number (Return Materials Authorization number) from Carmanah Customer Service is required prior to returning any
Carmanah Products. Carmanah reserves the right to refuse any items sent to Carmanah without an associated RMA number. To obtain an RMA number, please contact [email protected]
or Telephone 1-250-380-0052 or Fax 1-250-380-0062 worldwide – or Toll Free for US & Canada 1-866-247-6527.
Out of Warranty
Go Power! electronic products are non-repairable, Go Power! does not perform repairs on its products nor does it contract out those repairs to a third party. Go Power! does not supply schematics or replacement parts for any of its electronic products.
gpelectric.com | [page 49]
7. END OF LIFE - RECYCLING INFORMATION
Product E.O.L (End of life) Information
This product required the extraction and use of natural resources. It may contain substances that could be harmful to the environment or human health if improperly handled at the product’s end of life. In order to avoid release of such substances into the environment and to reduce the use of natural resources, we encourage you to recycle the GP-IC-2000 in an appropriate way that will ensure most of the materials are reused or recycled appropriately.
DO NOT DISPOSE OF THIS PRODUCT WITH NORMAL GARBAGE
The easiest way to recycle the GP-IC-2000 is to take the unit to a local certified e-waste (electronics waste) recycling centre.
Knowing for sure if your appliances are being recycled properly is tricky. If your in doubt just ask. Recyclers that are certified should gladly show you their certification. If the re-cycler is certified, chances are very high that they are recycling responsibly.
To find your local e-waste centre please contact your local municipality. The following website also has information on local recycling centres: www.earth911.com/recycling-center-search-guides
If you have no local certified e-waste recycling centre, the GP-IC-2000 can be dis-assembled manually and recycled responsibly.
A Phillips screwdriver is required to disassemble the GP-IC-2000. Note: The GP-IC-2000 should only be dis-assembled at the end of its service life, Go Power! provides no spare parts for the GP-IC-2000
1. Remove the screws holding the outer case to the base plate. The plastic handles can be removed from the outer case by pushing them out from the inside.
3
Metal Recycling
Aluminum
4
Metal case
7 Plastic handles
CFB
3 7
ABS
Acrylonitrile
Butadiene Styrene
2. Remove the screws holding the copper connectors - these can be recycled with metals (Copper).
Copper connectors
4 7
CFB
3. Remove the screws holding PCB #1.
People. Planet. Profit.
Carmanah Technologies
[page 50] | gpelectric.com
PCB #1
CFB
Recycling 7
(small electronics)
Local recycling centres can be found here; www.earth911.com/recycling-center-search-guides
END OF LIFE - RECYCLING INFORMATION
4. Remove the screws holding PCB #2.
PCB #2
3 4
PCB
(small electronics)
7
5. Remove the screws holding the transformer.
Transformer (Copper)
3 4 7
CFB
Metals
Copper
6. Remove the screws holding the fans.
7. Remove the screws holding PCB
#3.
8. The GP-IC-2000 has been fully dissambled www.earth911.com/recycling-center-search-guides
Fans
3 4
Recycling
(small electronics)
7
People. Planet. Profit.
Carmanah Technologies
PCB #3
3 4
PCB
(small electronics)
7
Metal Base
ALU
Aluminum
3 4
Local recycling centres can be found here; www.earth911.com/recycling-center-search-guides gpelectric.com | [page 51]
7
© 2016 Go Power! By Carmanah Technologies
Worldwide Technical Support and Product Information gpelectric.com
Carmanah Technologies Corporate Headquarters
250 Bay St, Victoria, BC Canada V9A 3K5
Tel: 1.866.247.6527
79497_MAN_GP_IC_2000_Rev_A powered by
®
advertisement
Key Features
- Pure Sine Wave Inverter
- 50-amp AC Pass Through
- Multi-stage Battery Charging
- Battery Temperature Sensor (BTS)
- Remote Control Port
- Built-in Handles
- LED Indicators
Related manuals
Frequently Answers and Questions
What is the maximum AC output power of the GP-IC2000-12-PKG?
How do I connect the battery temperature sensor?
Can I use the GP-IC2000-12-PKG with a generator?
advertisement
Table of contents
- 4 2. GENERAL INFORMATION
- 4 2.1 CAUTIONS
- 7 2.2 DISCLAIMERS
- 7 2.3 GP-IC-2000 KIT PARTS
- 7 2.3.1 PARTS CHECKLIST
- 8 2.4 UNIT FEATURES
- 10 2.5 UNIT DIMENSIONS
- 11 2.6 UNIT ACCESSORIES
- 11 2.7 INSTALLATION TOOLS AND MATERIALS
- 11 3. INSTALLATION
- 12 3.1 TYPICAL INVERTER / CHARGER SYSTEM OVERVIEW
- 16 3.2 LOCATION AND ENVIRONMENTAL REQUIREMENTS
- 17 3.3 MOUNTING THE INVERTER / CHARGER
- 18 3.4 GENERAL WIRING SPECIFICATIONS
- 19 3.5 DC WIRING
- 20 3.5.1 DC WIRE SIZING
- 20 3.5.2 DC OVERCURRENT PROTECTION AND DC DISCONNECT
- 20 3.5.3 PREPARING THE DC CABLES
- 20 3.5.4 DC CABLE CONNECTIONS
- 21 3.5.5 BATTERY TEMPERATURE SENSOR
- 22 3.5.6 WIRING THE INVERTER / CHARGER TO THE BATTERY BANK
- 23 3.5.7 BATTERY LAYOUTS
- 24 3.5.8 DC GROUNDING
- 25 3.6 AC WIRING
- 26 3.6.1 AC POWER SOURCES
- 26 3.6.2 AC WIRE SIZE AND OVERCURRENT PROTECTION
- 26 3.6.3 GFCI (GROUND FAULT CIRCUIT INTERRUPTION) OUTLETS
- 27 3.6.4 AC TERMINAL BLOCK CONNECTIONS
- 28 3.6.5 AC CABLE CONNECTIONS
- 31 3.6.7 AC WIRING 2 - Single Phase, 30A> Service, Single IN / Single OUT
- 32 3.6.8 AC WIRING 3 - Split Phase, 50A Service, Dual IN, Dual OUT, Option
- 33 3.6.9 AC WIRING 4 - Split Phase, 50A Service, Dual IN, Dual OUT, Option
- 34 3.6.10 GROUNDING THE INVERTER - AC GROUNDING
- 35 3.6.11 DISABLING THE NEUTRAL TO CHASSIS GROUND CONNECTION
- 36 3.6.12 GROUNDING ON BOATS
- 37 3.7 FINAL INSPECTION
- 37 3.8 TESTING THE INSTALLATION
- 37 3.9 WARNING LABELS
- 38 4. OPERATION
- 38 4.1 GENERAL OPERATING NOTES
- 40 4.2 AC POWER PASS THROUGH MODE
- 41 4.3 CHARGING MODE
- 42 4.4 POWER SHARING MODE
- 43 4.5 GENERATOR MODE
- 44 4.6 INVERTING MODE
- 45 4.7 BATTERY TEMPERATURE SENSOR OPERATION
- 45 4.8 FACTORY DEFAULT VALUES
- 46 4.9 GP-IC-2000 FAULT CONDITIONS
- 46 4.10 MAINTENANCE AND TROUBLESHOOTING
- 48 5. SPECIFICATIONS
- 49 6. WARRANTY RETURN PROCEDURE
- 50 7. PRODUCT END OF LIFE INFORMATION - RECYCLING