User’s Manual Model: 1042135
Important! Please read carefully and save this document.
This user’s manual contains important information about your combination Smoke and CO Alarm’s operation.
If you are installing this alarm for use by others, you must leave this manual (or a copy of it) with the end user.
Table of Contents
2
Welcome
3
Parts of this Alarm
4
Understanding Your Alarm
5
Where to Install 6-7
Where Not to Install 8
Set-Up and Installation
9 - 12
Installation of Adapter Plug
12 - 16
Wireless Interconnect
16 - 17
When the Alarm Sounds
17 - 18
Using the Silence Feature
18
Weekly Testing 19
Regular Maintenance
20
Alarm End of Life
20
Ionization and Photoelectric Technology
21
Fire Safety Tips
21 - 22
What You Need to Know About CO
23
Potential Sources of CO in the Home
24 - 25
Regulatory Information
26 - 28
Special Compliance
29 - 31
General Limitations
31 - 32
Troubleshooting Guide
33
Limited Warranty
34
Copyright and Technical Specifications
35
Welcome
Thank you for choosing Onelink by First Alert for your safety needs. In addition
to the alarm sounds, you canreceive notifications in case of an emergency to help
provide a warning of a fire or carbon monoxide leak while you are home or away.
Please take time to read this manual and make this alarm an integral part of your
family’s safety plan. Visit www.onelink.firstalert.com for additional information.
Contents
Smoke and
CO Alarm
Mounting
Bracket
Power Connector
/ Adapter Plugs
Junction
Box Screws
User’s
Manual
System Requirements
Wireless Network
Android or iOS Device
Onelink App
Required to use a 2.4 GHz wireless
connection and a compatible
802.11 b/g/n/ac router.
HomeKit™ requires an iPhone®, iPad®,
or iPod touch® with iOS 10 or later,
or Android® 5 or later.
Search and download the
Onelink Home app from the
App Store or Google Play.
3
Parts of this Alarm
8
3
1
9
2
6
4
5
11
7
10
4
1.
Test/Silence Button
4.
Hot (black) AC Wire
8.
Mounting Bracket
2.
Color Indicator Ring
5.
Neutral (white) AC Wire
9.
Mounting Slots
3.
Speaker
6.
Interconnect
(orange) AC Wire
10.
Turn Alarm Clockwise
to Attach
7.
Quick Connect
Power Connector
11.
Turn Alarm
Counterclockwise
to Remove
Understanding Your Alarm
LED Color
Patterns
Smoke / CO Events
Voice Guide
Power Up
Power Up and Welcome
“First Alert welcomes you to your Onelink Smoke
and Carbon Monoxide Alarm. The Onelink App will
guide you through the simple setup process.”
Programming, Silencing & Pairing
“[Location, example: “Hallway”] Location Programmed.”
Testing
“The testing is complete. The test is done and you are protected.”
Emergency
[voice complete]
Pairing
Alarm will flash blue during pairing.
“Testing Smoke” [beep beep beep!]
“Testing Carbon Monoxide” [beep beep beep beep!]
Testing
“Evacuate, Evacuate, there’s Fire in the [Location]!”
“Testing Alarms... The alarm will sound and for your
protection is very loud. This may take a few seconds.”
“Highest carbon monoxide level was 0 PPM.”
Emergency
“Evacuate! Evacuate! There is Smoke [or Carbon
Monoxide] in the [Location!]!”
“Highest carbon monoxide level was [Number] PPM.”
“Detector error.”
Malfunction
“Alarm has reached its End of Life. Replace Alarm in [Location].”
White
Low Battery
Information available via mobile app.
Power Indicator and Night Light
N/A
5
Where to Install
Minimum coverage for Smoke Alarms, as recommended by the National Fire Protection Association
(NFPA), is one Smoke Alarm on every floor, in every sleeping area, and in every bedroom (See
“Regulatory Information For Smoke Alarms” for details on the NFPA recommendations). For CO Alarms,
the National Fire Protection Association (NFPA) recommends that a CO Alarm should be centrally
located outside of each separate sleeping area in the immediate vicinity of the bedrooms. For added
protection, install additional CO Alarms in each separate bedroom, and on every level of your home.
NOTE: For added protection, install an additional Smoke/CO Alarm at least 15 feet (4.6 meters)
away from the furnace or fuel burning heat source where possible. In smaller homes or in
manufactured homes where this distance cannot be maintained, install the Alarm as far away as
possible from the furnace or other fuel burning source. Installing the Alarm closer than 15 feet
(4.6 meters) will not harm the Alarm, but may increase the frequency of unwanted alarms.
In general, install combination Smoke and Carbon Monoxide Alarms:
•
On every level of your home, including finished attics and basements.
•
Inside every bedroom, especially if people sleep with the door partly or completely closed.
•
In the hall near every sleeping area. If your home has multiple sleeping areas, install a unit
in each. If a hall is more than 40 feet (12 meters) long, install a unit at each end.
•
At the top of first-to-second floor stairs.
•
At the bottom of the basement stairs.
•
For additional coverage, install Alarms in all rooms, halls, and storage areas, where
temperatures normally remain between 40˚ F and 100˚ F (4.4˚ C and 37.8˚ C).
Recommended Placement
•
When installing on the wall, the top edge of Smoke Alarms should be placed between
4 inches (102 mm) and 6 inches (153 mm) from the wall/ceiling line.
•
When installing on the ceiling, place the alarm as close to the center as possible.
•
In either case, install at least 4 inches (102 mm) from where the wall and ceiling meet.
•
See Avoiding “Dead Air” Spaces for more information.
NOTE: For any location, make sure no door or other obstruction could
keep carbon monoxide or smoke from reaching the Alarm.
Installing Smoke/CO Alarms in Mobile Homes
For minimum security install one Smoke/CO Alarm as close to each sleeping area as possible.
For more security, put one unit in each room. Many older mobile homes (especially those built
before 1978) have little or no insulation. If your mobile home is not well insulated, or if you are
unsure of the amount of insulation, it is important to install units on inside walls only.
6
Where to Install (Continued)
4”
(102 mm)
minimum
CEILING
between 4”- 6”
(102 mm - 153 mm)
from ceiling
PLACE HERE
SPEAKER OPENING
IN UPPER LEFT
CORNER
DO NOT PLACE
IN THIS AREA
OR HERE
WALL
7
Where Not to Install
Do NOT locate this Smoke/CO Alarm:
•
In garages, furnace rooms, crawl spaces and unfinished attics. Avoid extremely dusty, dirty or greasy areas.
•
Where combustion particles are produced. Combustion particles form when something burns. Areas
to avoid include poorly ventilated kitchens, garages, and furnace rooms. Keep units at least 20 feet (6
meters) from the sources of combustion particles (stove, furnace, water heater, space heater) if possible.
In areas where a 20 foot (6 meter) distance is not possible – in modular, mobile, or smaller homes, for
example – it is recommended the Smoke Alarm be placed as far from these fuel-burning sources as
possible. The placement recommendations are intended to keep these Alarms at a reasonable distance
from a fuel-burning source, and thus reduce “unwanted” alarms. Unwanted alarms can occur if a Smoke
Alarm is placed directly next to a fuel-burning source. Ventilate these areas as much as possible.
•
Within 5 feet (1.5 meters) of any cooking appliance. In air streams near kitchens. Air currents
can draw cooking smoke into the smoke sensor and cause unwanted alarms.
•
In extremely humid areas. This Alarm should be at least 10 feet (3 meters) from a shower, sauna,
humidifier, vaporizer, dishwasher, laundry room, utility room, or other source of high humidity.
•
In direct sunlight.
•
In turbulent air, near ceiling fans or open windows. Blowing air may
prevent CO/smoke from reaching the sensors.
•
In areas where temperature is colder than 40˚ F (4.4˚C) or hotter than 100˚
F (37.8˚C). These areas include non air conditioned crawl spaces, unfinished
attics, uninsulated or poorly insulated ceilings, porches, and garages.
•
In insect infested areas. Insects can clog the openings to sensing chamber.
•
Less than 12 inches (305 mm) away from fluorescent lights. Electrical “noise” can interfere with the sensor.
•
In “dead air” spaces. See below for additional information.
Installing Smoke/CO Alarms in Mobile Homes
“Dead air” spaces may prevent smoke from reaching the Smoke/CO Alarm. To
avoid dead air spaces, follow installation recommendations below.
8
•
On ceilings, install Smoke/CO Alarms as close to the center of the ceiling as possible. If this is
not possible, install the Smoke/CO Alarm at least 4 inches (102 mm) from the wall or corner.
•
For wall mounting (if allowed by building codes), the top edge of Smoke/CO Alarms should be placed
between 4 inches (102 mm) and 6 inches (153 mm) from the wall/ceiling line, below typical “dead air” spaces.
•
On a peaked, gabled, or cathedral ceiling, install first Smoke/CO Alarm within 3 feet (0.9 meters) of the
peak of the ceiling, measured horizontally. Additional Smoke/CO Alarms may be required depending on
the length, angle, etc. of the ceiling’s slope. Refer to NFPA 72 for details on requirements for sloped or
peaked ceilings.
~
Set-Up & Installation
DANGER: ELECTRICAL SHOCK HAZARD. Turn off power to the
area where you will install this unit at the circuit breaker or fuse box
before beginning installation. Failure to turn off the power before
installation may result in serious electrical shock, injury or death
!
IMPORTANT: The top edge of the Alarm MUST be between 4 and 6
inches down from the ceiling. When wall mounting, the speaker opening
is in the upper left corner, as indicated by the illustration below.
Tools you will need:
•
Needle-nose pliers or utility knife
•
Standard phillips screwdriver
•
Wire strippers
Speaker
Opening
Ensure the iOS software is updated to iOS 10 or later or Android 5 or later.
Step 1
Download the free Onelink app from the App Store
or Google Play and follow set-up instructions.
Step 2
Attach the mounting bracket to the junction box.
Step 3
Using wire nuts, connect the power
connector to the household wiring.
If any unit in the series does not alarm with the test button, TURN OFF POWER and recheck connections.
If it does not alarm with the test button when you restore power, replace it immediately.
Improper wiring of the power connector or the wiring leading to the power connector
will cause damage to the Alarm and may lead to a non-functioning Alarm.
NOTE: Electrical ratings: 120V AC 60 Hz, 0.065 A 3.0 Lithium Battery Backup
9
Set-Up & Installation (Continued)
}
6
A
7
8
5
5
4
4
3
3
2
1
1
10
1. Smoke/CO Alarm
2. Ceiling or Wall
3. Power Connector
4. Wire Nut
5. Junction Box
6. Neutral Wire (white)
7. Interconnect Wire (orange)
8. Hot Wire (black)
}
B
Set-Up & Installation (Continued)
Interconnected units must meet ALL of the following requirements:
•
A maximum of 18 compatible units may be interconnected (Maximum of 12 Smoke Alarms).
•
The same fuse or circuit breaker must power all interconnected units.
•
The total length of wire interconnecting the units should be less than 1000 feet (300 meters).
This type of wire is commonly available at Hardware and Electrical Supply stores.
•
All wiring must conform to all local electrical codes and NFPA 70 (NEC). Refer to NFPA
72, NFPA 101, and/or your local building code for further connection requirements.
Stand-Alone Alarm Only:
•
Connect the white wire on the power connector to the neutral wire in the junction box.
•
Connect the black wire on the power connector to the hot wire in the junction box.
•
Tuck the orange wire inside the junction box. It is used for interconnect only.
Interconnect Units Only:
!
IMPORTANT FEATURE: 1042135 is compatible with
all First Alert and BRK hardwired alarm models.
Strip off about 1/2” (12 mm) of the plastic coating on the orange wire on the power connector.
•
Connect the white wire on the power connector to the neutral wire in the junction box.
•
Connect the black wire on the power connector to the hot wire in the junction box.
•
Connect the orange wire on the power connector to the interconnect wire in the junction box.
Repeat for each unit you are interconnecting. Never connect the hot or neutral wires in the junction
box to the orange interconnect wire. Never cross hot and neutral wires between Alarms.
!
WARNING: Improper wiring of the power connector or the wiring leading to the power
connector will cause damage to the Alarm and may lead to a non-functioning Alarm.
If you need to remove the power connector, turn POWER OFF first. Insert a flat screwdriver blade between the
power connector and the security tab inside the power input block. Gently pry back the tab and pull the
connector free.
Step 4
Plug the power connector into the back of the alarm.
11
Set-Up & Installation (Continued)
Step 5
Position the base of the Alarm over the mounting bracket, and turn
the alarm clockwise(right) until the unit is in its place. This activates
the battery back-up. Once unit is activated, it can not be turned off.
NOTE: After you activate the Alarm, the Color Indicator Ring will power up and the Alarm will
welcome you. To program your alarm, follow the instructions provided in the Onelink app.
!
WARNING: iOS and Android device notifications require a functional
Wireless connection. For best results, recommended to use with a 802.11
b/g/n/ac router. The notifications are only as reliable as your Wireless network
and are not a substitute for a third party emergency monitoring service.
This Smoke/CO Alarm is designed to be mounted on any standard wiring junction box up to a
4-inch (10 cm) size, on either the ceiling or wall (if allowed by local codes). Read “Where to Install
This Alarm” and “Where This Alarm Should Not Be Installed” before you begin installation.
STAND-ALONE ALARM ONLY:
•
If you are only installing one Smoke Alarm, restore power to the junction box.
INTERCONNECTED UNITS ONLY:
•
If you are interconnecting multiple Smoke Alarms, repeat steps 1-5 for each Smoke
Alarm in the series. When you are finished, restore power to the junction box.
!
12
WARNING: Make sure the Alarm is not receiving excessively noisy power.
Examples of noisy power could be major appliances on the same circuit, power
from a generator or solar power, light dimmer on the same circuit or mounted near
fluorescent lighting. Excessively noisy power may cause damage to your Alarm.
Installation of Adapter Plug
NOTE: Adapter plugs may not be included in all SKUs.
Installation Instructions:
Step 1
Verify which COMPATIBLE MODELS are installed in your system to determine
the Adapter Plug to use.
Compatible Models:
All of the following BRK/Kidde ® / Fyrnetics ® / Lifesaver ® /Firex Alarms are compatible with 1042135 Alarm, and
can be interconnected using the appropriate Adapter Plug. Visit www.firstalert.com/product/onelinksmokeco
to view alarms compatible with Onelink Smart Smoke & Carbon Monoxide Alarm.
First Alert® / BRK® Alarms
!
IMPORTANT FEATURE: 1042135 is compatible with all First Alert and BRK hardwired alarm models.
NOTE: Adapter Plug can be used on Firex® Models manufactured on or before January 1, 2005.
White
Orange
Plug Pin
View
Black
Side View
NOTE: Twist tie should not be removed.
13
Installation of Adapter Plug (Continued)
!
WARNING: Installation of this unit must conform to the electrical codes in your area; Article 760
of NFPA 70 (NEC), NFPA 72, NFPA 101; SBC (SBCCI); UBC (ICBO); NBC (BOCA); OTFDC (CABO),
and any other local or building codes that may apply. Wiring and installation must be performed by
a licensed electrician. Failure to follow these guidelines may result in injury or property damage.
This unit must be powered by a 24-hour, 120VAC pure sine wave 60Hz circuit. Be sure the
circuit cannot be turned off by a switch, dimmer, or ground fault circuit interrupter. Failure to
connect this unit to a 24-hour circuit may prevent it from providing constant protection.
Step 2
Turn off AC power.
Step 3
Install new mounting bracket.
Step 4
Using wire nuts, connect the power connector to the household wiring.
Step 5
Connect the black end of the appropriate Adapter Plug to the existing power connector.
NOTE: There may not be enough room for the Adapter Plug and additional wiring to fit in the junction
box. If not, the old power connector must be removed and replaced with the BRK® Power Connector.
14
Step 6
Connect the other end of the Adapter Plug to First Alert ® / BRK® Alarm.
Step 7
Check all connections. Make sure all plugs are completely connected and snapped
together. Ensure the Adapter Plug is securely connected to the existing Power Connector.
Step 8
Install the base of the Alarm to the mounting bracket.
Step 9
Restore power to the junction box.
Step 10
Test each Alarm. Press and hold the test button until the unit alarms. When testing a
series of interconnected units you must test each unit individually. Make sure all units
alarm when each one is tested.
~
Installation of Adapter Plug (Continued)
DANGER: If any unit in the series does not alarm, TURN OFF POWER
and recheck connections. RESTORE POWER. If any unit within
interconnected alarms does not alarm, replace it immediately.
5
1
4
3
1.
Mounting Bracket
2.
First Alert® / BRK® Alarm
3.
Kidde® Adapter
4.
Firex® Adapter
5.
Existing compatible
power connector
Electrical Rating:
120V AC, 100mA Maximum
Not for Current Interruption
2
15
Installation of Adapter Plug (Continued)
!
IMPORTANT: Interconnect units within a single family residence only. Otherwise all households
will experience unwanted alarms when you test any unit in the series. Interconnected units will
only work if they are wired to compatible units and all requirements are met. This unit is designed
to be compatible with First Alert® and BRK Electronics® Models listed in the User’s Manual.
Interconnected units must meet ALL of the following requirements:
•
A maximum of 18 compatible units may be interconnected (Maximum of 12 Smoke Alarms – Except Firex®
models PG-40 and G-6).
•
The same fuse or circuit breaker must power all interconnected units.
•
The total length of wire interconnecting the units should be less than 1000 feet (300 meters). The interconnect wire
should be #18 gauge or larger, rated at least 300V. If an interconnect wire is not already part of your household
wiring, you will need to install one. This type of wire is commonly available at Hardware and Electrical Supply stores.
•
All wiring must conform to all local electrical codes and Article 760 of NFPA 70 (NEC). Refer to
NFPA 72, NFPA 101, and/or your local building code for further connection requirements.
!
WARNING: Failure to meet any of the above requirements could damage the units and cause them
to malfunction, removing your protection. AC and AC/DC Alarms can be interconnected. Under
AC power, all units will alarm when one senses smoke. When power is interrupted, only the AC/DC
units in the series will continue to send and receive signals. AC powered Alarms will not operate.
Wireless Interconnect
Benefits of Wireless Interconnect
The wireless interconnect feature on this alarm allows you to connect each of your First Alert Onelink alarms
so when one alarm sounds, they all will sound.
!
16
WARNING: Install alarms and test to assure range and reliability of interconnection throughout the house.
•
First Alert Onelink alarms can typically communicate with each other if they’re 50ft (15m) apart inside a home.
Keep in mind that some features of a home may reduce the interconnect range and reliability of
interconnection, including the number of floors, number/size of rooms, furniture, type of building
material,suspended ceilings, ductwork, large metallic appliances and metal studs. This kind of interference may
be fixed by adding more Onelink alarms that can route wireless signals around any various obstructions.
•
Make sure you test your Onelink alarms for proper interconnection via the weekly testing.
Wireless Interconnect (Continued)
Wireless Frequency
This alarm supports wireless frequency of 2.4Ghz, 802.11 b/g/n/ac router required.
Adding Additional Alarms
Simply follow the instructions on your Onelink app to add additional alarms to your account.
Identification of Events
If your alarm sounds, it is important to first identify the type of alarm.
When the Alarm Sounds
What To Do If The Smoke Alarm Sounds
•
If the unit alarms and you are not testing the unit, it is warning you of a potentially dangerous situation that
requires your immediate attention. NEVER ignore any alarm. Ignoring the alarm may result in injury or death.
•
If the unit alarms get everyone out of the house immediately.
What To Do In Case of a Fire
•
Don’t panic; stay clam. Follow your family escape plan.
•
Get out of the house as quickly as possible. Don’t stop to get dressed or collect anything.
•
Feel doors with the back of your hand before opening them. If a door is cool, open it slowly. Don’t open a hot door.
Keep doors and windows closed, unless you must escape through them.
•
Cover your nose and mouth with a cloth (preferably damp. Take short, shallow breaths.
•
Meet at your planned meeting place outside your home, and do a head count to make sure everybody got
out safely. Call the Fire Department as soon as possible from outside. Give your address, then your name.
•
Never go back inside a burning building for any reason.
•
Contact your Fire Department for ideas on making your home safer.
What To Do If The CO Alarm Sounds
1.
Press the Test/Silence button (On App or on unit).
2.
Call your emergency services, fire department or 911.
3.
Immediately move to fresh air—outdoors or by an open door or window. Do a head count
to check that all persons are accounted for. Do not re-enter the premises, or move away
from the open door or window until the emergency services responder has arrived, the
premises have been aired out, and your CO Alarm remains in its normal condition.
17
When the Alarm Sounds (Continued)
4.
After following steps 1-3, if your CO Alarm reactivates within a 24-hour period, repeat steps 1-3 and call a qualified
appliance technician to investigate for sources of CO from fuel-burning equipment and appliances, and inspect for
proper operation of this equipment. If problems are identified during this inspection have the equipment serviced
immediately. Note any combustion equipment not inspected by the technician, and consult the manufacturers’
instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make
sure that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the residence.
NOTE: A qualified appliance technician is defined as “a person, firm, corporation, or company that either in person or through a
representative, is engaged in and responsible for the installation, testing, servicing, or replacement of heating, ventilation, air conditioning
(HVAC) equipment, combustion appliances and equipment, and/or gas fireplaces or other decorative combustion equipment.”
WARNING: Actuation of this device indicates the presence of carbon monoxide (CO) which can KILL YOU.
!
If alarm signal sounds (description of alarm signal, eg four beeps): (1) immediately move to fresh air outdoors or by
an open window. check that all persons are accounted for. Do not reenter the premise or move away from the open
door/window until the emergency service responders have arrived, the premises have been aired out, and your alarm
remains in its normal condition; (2) call you emergency local service (telephone number) (fire department or 911)
(ii) If “service” signal sounds (description of the trouble signal eg. one beep)
Using the Silence Feature
The Silence Feature
This feature is intended to temporarily silence the horn while you identify and correct the problem. Do not use the Silence Feature in
emergency situations. It will not correct a CO problem or extinguish a fire. The Silence Feature can temporarily quiet an unwanted
alarm for several minutes. You can silence this Smoke/CO Alarm by pressing the Test/Silence button on the alarm cover for at
least 3-5 seconds or via the Onelink app. After the Test/Silence button is released, the Red LED stops during the silence mode.
Silence the End of Life Signal
This silence feature can temporarily quiet the End of Life warning “chirp” for up to 2 days. You can silence the End of
Life warning “chirp” by pressing the Test/Silence button or via the Onelink app. The horn will chirp, acknowledging
that the End of Life silence feature has been activated. After approximately 2 days, the End of Life “chirp” will resume.
!
WARNING: Never deactivate the unit to quiet an unwanted alarm.
Deactivating the alarm disables the unit and removes your protection.
When the Smoke Alarm is Silenced
18
When the CO Alarm is Silenced
The Smoke Alarm will remain silent for up to
15 minutes, then return to normal operation.
The CO Alarm will remain silent for up to 4 minutes.
If the smoke has not cleared or continues to
increase, the device will go back into alarm.
After 4 minutes, if CO levels remain potentially
dangerous, the horn will start sounding again.
Weekly Testing
!
WARNING: NEVER use an open flame of any kind to test this unit. You might
accidentally damage or set fire to the unit or to your home. NEVER use vehicle
exhaust! Exhaust may cause permanent damage and voids your warranty.
!
WARNING: DO NOT stand close to the Alarm when the horn is sounding. Exposure at close
!
CAUTION: It is important to test this unit every week to make sure it is working properly.
Using the test button is the recommended way to test this Smoke/CO Alarm.
!
WARNING: Test device operation after vehicle has been in storage, before each trip,
range may be harmful to your hearing. When testing, step away when horn starts sounding.
and at least once per week during use.
You can test this Smoke/CO Alarm by pressing and holding the Test/Silence button
on the Alarm cover until Alarm Voice says “Testing” (typically 3-5 seconds).
During testing, you will see and hear the following sequence:
•
“The Alarm Voice will say “Testing Alarms… The Alarm will sound and for your protection is very
loud. This may take a few seconds.” The LED chases Blue. The Alarm Voice will say “Testing Smoke.”
The Horn will sound 3 beeps, twice. The LED chases and flashes Red. The Alarm Voice will say
“Evacuate, Evacuate, there’s Fire in the [Location. Example: “Kitchen”].” The LED flashes green.”
•
“ Next, the Alarm Voice will say “Testing Carbon Monoxide.” The Horn will sound 4 beeps,
twice. The LED chases and flashes Red. The Alarm Voice will say “Evacuate, Evacuate,
there’s Carbon Monoxide in the [Location. Example: “Kitchen”].” The LED flashes green.
The Alarm Voice will say “Highest carbon monoxide level was 0 PPM.” The LED chases Blue.
The Alarm Voice will then say “The testing is almost complete.” After a pause, the Alarm
Voice will say “The test is done, and you are protected.” The LED flashes green.
If the unit does not alarm, make sure it has been activated correctly, and test again. If the unit still
does not alarm, replace it immediately.
19
Regular Maintenance
This unit has been designed to be as maintenance-free as possible, but there are a few simple things
you must do to keep it working properly:
•
Test it at least once a week.
•
Clean the Smoke/CO Alarm at least once a month; gently vacuum the outside of the Smoke/CO
Alarm using your household vacuum’s soft brush attachment. A can of clean compressed air (sold at
computer or office supply stores) may also be used. Follow manufacturer instructions for use. Test
the Smoke/CO Alarm. Never use water, cleaners or solvents since they may damage the unit.
•
If the Smoke/CO Alarm becomes contaminated by excessive dirt, dust and/or grime, and
cannot be cleaned to avoid unwanted alarms, replace the unit immediately.
•
Relocate the unit if it sounds frequent unwanted alarms. See “Where
This Alarm Should Not Be Installed” for details.
IMPORTANT: Actual battery service life depends on the Smoke/CO Alarm and the environment
in which it is installed. Regardless of the manufacturer’s suggested battery life, you MUST
replace the Alarm immediately once the unit starts “chirping” (the “low battery warning”).
!
Alarm End of Life
Permanently Deactivating the Alarm
After 10 years of operation or low battery warning, deactivate the Alarm by following the diagram
below: Score label on dotted line and move switch all the way to the right to DEACTIVATE mode.
NOTE: At end of life or low battery indication (chirp): unit must be put into deactivation mode
to deactivate remaining stored energy in battery. Unit will no longer function once put into this
mode. Unit will resist re-mounting. Once deactivated, replace Alarm immediately.
SINGLE AND/OR MULTIPLE STATION SMOKE & CO ALARM
PHOTOELECTRIC
WWARNING!
SINGLE AND/OR MULTIPLE STATION SMOKE & CO ALARM
MODEL NO. 1042135
120V AC 60Hz, 0.065 A 3.0 Lithium Battery Backup
SMOKE SENSITIVITY: 0.98 – 2.74 %/ft OBSC.
4
N04 - 312
4
N04 - 312
673
-16 4
673
-16 4
CONFORMS TO
UL STD 217 & UL STD 2034
XICO
XICO
CARBON MONOXIDE SENSITIVITY: If CO levels reach 70ppm,
it must activate within 60-240 minutes. At 150ppm within
10-50 minutes. At 400ppm within 4-15 minutes.
Refer to user’s manual for more information.
NOTE: Ensure the AC plug is connected 1st prior to
mounting the unit to activate the battery back-up.
Contains Transmitter Modules FCC ID: M7U-BT1IOT
and FCC ID: TLZ-CU300. Contains Transmitter Modules
IC: 10190A-BT1IOT and IC: 6100A-CU300
HOW TO DEACTIVATE ALARM:
Replace Alarm 10 Yrs. After Installation
To deactivate battery, score label on dotted line
Follow and Retain User’s Manual:
and move switch all the way to the right. Once
BRK Brands, Inc.
Installed On
deactivated, the alarm cannot be reactivated
1301 Joe Battle, El Paso, TX 79936.
and must be replaced.
Consumer Affairs:
ALARM GUIDE: SMOKE ALARM: Three beeps.
1-833-ONELINK (1-833-663-5465) Replace By
CO ALARM: Four beeps.
www.onelink.firstalert.com
MALFUNCTION: Three “chirps” per minute. Replace alarm.
BLACK • LINE
END OF LIFE: Five “chirps” per minute. Replace alarm.
ORANGE • INTERCONNECT
WHITE • NEUTRAL
HOW TO ACTIVATE ALARM:
Align alarm with mounting bracket and turn
clockwise. Chasing Green LED's and Welcome
Message indicate alarm is activated.
IN ME
IN ME
W IMPORTANT!
MAINTENANCE AND TESTING:
Alarm is sealed, with no serviceable parts. Battery is not
replaceable. Constant use at high or low temperatures or
high humidity may reduce battery life. Test after
installation, weekly, and after cleaning. Gently vacuum
monthly. Never use water, cleaners or solvents.
DEACTIVATE
PHOTOELECTRIC
WWARNING!
XXX-XX-XXX
MA
DE
MA
DE
Carbon monoxide cannot be seen or smelled but can kill you.
If alarm signal sounds: 1. Operate Test/Silence button.
2. Call your emergency services. (Fire Dept. or 911)
3. Immediately move to fresh air - outdoors or by an open
door/window.
1
XXX-XX-XXX
W IMPORTANT!
MAINTENANCE AND TESTING:
Alarm is sealed, with no serviceable parts. Battery is not
replaceable. Constant use at high or low temperatures or
high humidity may reduce battery life. Test after
installation, weekly, and after cleaning. Gently vacuum
monthly. Never use water, cleaners or solvents.
CARBON MONOXIDE SENSITIVITY: If CO levels reach 70ppm,
it must activate within 60-240 minutes. At 150ppm within
10-50 minutes. At 400ppm within 4-15 minutes.
Refer to user’s manual for more information.
NOTE: Ensure the AC plug is connected 1st prior to
mounting the unit to activate the battery back-up.
Contains Transmitter Modules FCC ID: M7U-BT1IOT
and FCC ID: TLZ-CU300. Contains Transmitter Modules
IC: 10190A-BT1IOT and IC: 6100A-CU300
HOW TO DEACTIVATE ALARM:
Replace Alarm 10 Yrs. After Installation
To deactivate battery, score label on dotted line
Follow and Retain User’s Manual:
and move switch all the way to the right. Once
BRK Brands, Inc.
Installed On
deactivated, the alarm cannot be reactivated
1301 Joe Battle, El Paso, TX 79936.
and must be replaced.
Consumer Affairs:
ALARM GUIDE: SMOKE ALARM: Three beeps.
1-833-ONELINK (1-833-663-5465) Replace By
CO ALARM: Four beeps.
www.onelink.firstalert.com
MALFUNCTION: Three “chirps” per minute. Replace alarm.
BLACK • LINE
END OF LIFE: Five “chirps” per minute. Replace alarm.
ORANGE • INTERCONNECT
WHITE • NEUTRAL
HOW TO ACTIVATE ALARM:
Align alarm with mounting bracket and turn
clockwise. Chasing Green LED's and Welcome
Message indicate alarm is activated.
DEACTIVATE
3055574
20
MODEL NO. 1042135
120V AC 60Hz, 0.065 A 3.0 Lithium Battery Backup
SMOKE SENSITIVITY: 0.98 – 2.74 %/ft OBSC.
Carbon monoxide cannot be seen or smelled but can kill you.
If alarm signal sounds: 1. Operate Test/Silence button.
2. Call your emergency services. (Fire Dept. or 911)
3. Immediately move to fresh air - outdoors or by an open
door/window.
CONFORMS TO
UL STD 217 & UL STD 2034
3055574
2
1.
Score label on dotted line
2.
Slide switch to the right
Ionization & Photoelectric Technology
This alarm uses Photoelectric technology.
All First Alert ® Onelink ® Smoke Alarms conform to regulatory requirements, including UL217 and are designed
to detect particles of combustion. Smoke particles of varying number and size are produced in all fires.
Ionization Technology
Ionization technology is generally more sensitive than Photoelectric technology at
detecting small particles, which tend to be produced in greater amounts by flaming
fires, which consume combustible materials rapidly and spread quickly. Sources of
these fires may include paper burning in a wastebasket, or a grease fire in the kitchen.
Photoelectric Technology
Photoelectric technology is generally more sensitive than ionization technology
at detecting large particles, which tend to be produced in greater amounts
by smoldering fires, which may smolder for hours before bursting into flame.
Sources of these fires may include cigarettes burning in couches or bedding.
NOTE: For maximum protection, use both types of Smoke Alarms on each level and in every bedroom
of your home.
Fire Safety Tips
Follow safety rules and prevent hazardous situations:
1.
Use smoking materials properly. Never smoke in bed.
2.
Keep matches or lighters away from children.
3.
Store flammable materials in proper containers.
4.
Keep electrical appliances in good condition and don’t overload electrical circuits.
5.
Keep stoves, barbecue grills, fireplaces and chimneys grease-free and debris-free.
6.
Never leave anything cooking on the stove unattended.
7.
Keep portable heaters and open flames, like candles, away from flammable materials.
8.
Don’t let rubbish accumulate.
21
Fire Safety Tips (Continued)
Basic Safety Information
Keep alarms clean, and test them weekly. Replace alarms immediately if they are not working
properly. Smoke alarms that do not work cannot alert you to a fire. Keep at least one working
fire extinguisher on every floor, and an additional one in the kitchen. Have fire escape ladders
or other reliable means of escape from an upper floor in case stairs are blocked.
!
IMPORTANT: Dangers, Warnings and Cautions alert you to important operating instructions
or to potentially hazardous situations. Pay special attention to these items. This Smoke/CO
Alarm is approved for use in single-family residences. It is NOT designed for marine or RV use.
!
CAUTION: This combination Smoke/Carbon Monoxide Alarm has two separate alarms.
The CO Alarm is not designed to detect fire or any other gas. It will only indicate the
presence of carbon monoxide gas at the sensor. Carbon monoxide gas may be present
in other areas. The Smoke Alarm will only indicate the presence of smoke that reaches
the sensor. The Smoke Alarm is not designed to sense gas, heat or flames.
!
22
WARNING: This unit will not operate without battery power. The Smoke/CO Alarm cannot
work until you activate the battery power pack. NEVER ignore any alarm. See “What To Do If
Your Smoke/Co Alarm Sounds” on page 11 for more information on how to respond to an alarm.
Failure to respond can result in injury or death. The Silence Features are for your convenience
only and will not correct a problem. See “Using the Silence Feature” on page 12 for details.
Always check your home for a potential problem after any alarm. Failure to do so can result in
injury or death. Test this Smoke/CO Alarm once a week. If the alarm ever fails to test correctly,
have it replaced immediately! If the alarm is not working properly, it cannot alert you to a
problem. This product is intended for use in ordinary indoor locations of family living units.
It is not designed to measure CO levels in compliance with Occupational Safety and Health
Administration (OSHA) commercial or industrial standards. Individuals with medical conditions
that may make them more sensitive to carbon monoxide may consider using warning devices
which provide audible and visual signals for carbon monoxide concentrations under 30ppm. For
additional information on carbon monoxide and your medical condition, contact your physician.
!
CAUTION: This device is designed to protect individuals from the acute
effects of carbon monoxide exposure. it will not fully safeguard individuals with
specific medical conditions. If in doubt, consult medical practitioner.
!
WARNING: This product is intended for use in ordinary indoor residential areas. It is
not designed to measure compliance with commercial and industrial standards.
What You Need to Know About CO
What is CO?
CO is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely,
or are exposed to heat (usually fire). Electrical appliances typically do not produce CO.
These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline, kerosene, and propane.
Common appliances are often sources of CO. If they are not properly maintained, are improperly ventilated,
or malfunction, CO levels can rise quickly. CO is a real danger now that homes are more energy efficient.
“Air-tight” homes with added insulation, sealed windows, and other weatherproofing can “trap” CO inside.
Symptoms of CO Poisoning
The following symptoms may be related to CARBON MONOXIDE POISONING and should be discussed with
ALL members of the household:
Mild exposure: Headaches, running nose, sore eyes, often described as “flu”-like symptoms;
Medium Exposure: Dizziness, drowsiness, vomiting;
Extreme Exposure: : unconsciousness, brain damage, death.
Many cases of reported CARBON MONOXIDE POISONING indicate that while victims are aware they are not well,
they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance.
!
IMPORTANT: This CO Alarm measures exposure to CO over time. It alarms if CO levels are
extremely high in a short period of time, or if CO levels reach a certain minimum over a long
period of time. The CO Alarm generally sounds an alarm before the onset of symptoms in
average, healthy adults. Why is this important? Because you need to be warned of a potential
CO problem while you can still react in time. In many reported cases of CO exposure, victims
may be aware that they are not feeling well, but become disoriented and can no longer
react well enough to exit the building or get help. Also, young children and pets may be
the first affected. The average healthy adult might not feel any symptoms when the CO
Alarm sounds. However, people with cardiac or respiratory problems, infants, unborn babies,
pregnant mothers, or elderly people can be more quickly and severely affected by CO. If
you experience even mild symptoms of CO poisoning, consult your doctor immediately!
Finding the Source of CO After an Alarm
Carbon monoxide is an odorless, invisible gas, which often makes it difficult to locate the source of
CO after an alarm. These are a few of the factors that can make it difficult to locate sources of CO:
•
House well ventilated before the investigator arrives.
•
Problem caused by “backdrafting.”
•
Transient CO problem caused by special circumstances.
Because CO may dissipate by the time an investigator arrives, it may be difficult to locate the source of CO.
BRK Brands, Inc. shall not be obligated to pay for any carbon monoxide investigation or service call.
23
Potential Sources of CO in the Home
Fuel-Burning Appliances: Like portable heater, gas or wood burning fireplace, gas kitchen
range or cooktop, gas clothes dryer.
Damaged or Insufficient Venting: Corroded or disconnected water heater vent pipe, leaking chimney
pipe or flue, or cracked heat exchanger, blocked or clogged chimney opening.
Improper Use of Appliance/Device: Operating a barbecue grill or vehicle in an enclosed area
(like a garage or screened porch).
Transient CO Problems: “Transient” or on-again-off-again CO problems can be caused by outdoor
conditions and other special circumstances. The following conditions can result in transient CO situations:
1.
Excessive spillage or reverse venting of fuel appliances caused by outdoor conditions such as:
•
ind direction and/or velocity, including high, gusty winds. Heavy air in the vent pipes (cold/humid air
W
with extended periods between cycles).
•
N egative pressure differential resulting from the use of exhaust fans.
•
Several appliances running at the same time competing for limited fresh air.
•
Vent pipe connections vibrating loose from clothes dryers, furnaces, or water heaters.
•
O bstructions in or unconventional vent pipe designs which can amplify the above situations.
2.
Extended operation of unvented fuel burning devices (range, oven, fireplace).
3.
Temperature inversions, which can trap exhaust close to the ground.
4.
Car idling in an open or closed attached garage, or near a home.
These conditions are dangerous because they can trap exhaust in your home. Since these conditions can
come and go, they are also hard to recreate during a CO investigation.
24
Potential Sources of CO in the Home (Continued)
How Can I Protect My Family From CO Poisoning?
A CO Alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before Carbon
Monoxide levels become threatening for average, healthy adults.
A CO Alarm is not a substitute for proper maintenance of home appliances.
To help prevent CO problems and reduce the risk of CO poisoning:
•
Clean chimneys and flues yearly. Keep them free of debris, leaves, and nests for proper air flow.
Also, have a professional check for rust and corrosion, cracks, or separations. These conditions can
prevent proper air movement and cause back-drafting. Never “cap” or cover a chimney in any way that
would block air flow.
•
Test and maintain all fuel-burning equipment annually. Many local gas or oil companies and HVAC
companies offer appliance inspections for a nominal fee.
•
Make regular visual inspections of all fuel-burning appliances. Check appliances for excessive rust
and scaling. Also check the flame on the burner and pilot lights. The flame should be blue. A yellow
flame means fuel is not being burned completely and CO may be present. Keep the blower door on the
furnace closed. Use vents or fans when they are available on all fuel-burning appliances. Make sure
appliances are vented to the outside. Do not grill or barbecue indoors, or in garages or onscreen porches.
•
heck for exhaust back-flow from CO sources. Check the draft hood on an operating furnace for a
C
back-draft. Look for cracks on furnace heat exchangers.
•
C heck the house or garage on the other side of shared wall.
•
eep windows and doors open slightly. If you suspect that CO is escaping into your home,
K
open a window or a door. Opening windows and doors can significantly decrease CO levels.
25
Regulatory Information for CO Alarms
What Levels of CO Cause an Alarm?
Underwriters Laboratories Inc. Standard UL2034 requires residential CO Alarms to sound when exposed to
levels ofCO and exposure times as described below. They are measured in partsper million (ppm) of CO
over time (in minutes).
UL2034 Required Alarm Points*:
•
If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN 4 & 15 MINUTES.
•
If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN 10 & 50 MINUTES.
•
If the alarm is exposed to 70 ppm of CO, IT MUST ALARM BETWEEN 60 & 240 MINUTES.
*Approximately 10% of COHb exposure at levels of 10% to 95% Relative Humidity (RH).
This unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days.
!
IMPORTANT: CO alarms are designed to alarm before there is an immediate life threat.
Since you cannot see or smell CO, never assume it’s not present. An exposure to 100
ppm of CO for 20 minutes may not affect average, healthy adults but after 4 hours the
same level may cause headaches. An exposure to 400 ppm of CO may cause headaches
in average, healthy adults after 35 minutes, but can cause death after 2 hours.
Standards
Underwriters Laboratories Inc. Single and Multiple Station carbon monoxide alarms UL2034. According to
Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon monoxide alarms covered by these requirements
are intended to respond to the presence of carbon monoxide from sources such as, but not limited to, exhaust
from internal-combustion engines, abnormal operation of fuel-fired appliances, and fireplaces. CO Alarms
are intended to alarm at carbon monoxide levels below those that could cause a loss of ability to react to the
dangers of Carbon Monoxide exposure.” This CO Alarm monitors the air at the Alarm, and is designed to alarm
before CO levels become life threatening. This allows you precious time to leave the house and correct the
problem. This is only possible if Alarms are located, installed, and maintained as described in this manual.
Gas Detection at Typical Temperature and Humidity Ranges
The CO Alarm is not formulated to detect CO levels below 30 ppm typically. Tested for false alarm resistance
to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol
(200 ppm) and Carbon Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts per million.
Audible Alarm
85 dB minimum at 10 feet (3 meters).
26
Regulatory Information for Smoke Alarms
Installing Smoke Alarms in Single-Family Residences
The National Fire Protection Association (NFPA), recommends one Smoke Alarm on every floor,
in every sleeping area, and in every bedroom. In new construction, the Smoke Alarms must be AC
powered and interconnected. See “Agency Placement Recommendations” for details. For additional
coverage, it is recommended that you install a Smoke Alarm in all rooms, halls, storage areas, finished
attics, and basements, where temperatures normally remain between 40˚ F (4.4˚ C) and 100˚ F (37.8˚
C). Make sure no door or other obstruction could keep smoke from reaching the Smoke Alarms.
For your information, the National Fire Alarm and Signaling Code, NFPA 72, reads as follows:
Required Detection. Where required by applicable laws, codes, or standards for a specific type of
occupancy, approved single- and multiple-station smoke alarms shall be installed as follows:
•
In all sleeping rooms and guest rooms
•
Outside of each separate dwelling unit sleeping area, within 21 ft (6.4 m) of any door to a sleeping room,
the distance measured along a path of travel
•
On every level of a dwelling unit, including basements
•
On every level of a residential board and care occupancy (small facility), including basements and
excluding crawl spaces and unfinished attics
•
In the living area(s) of a guest suite In the living area(s) of a residential board and care occupancy
!
IMPORTANT: Specific requirements for Smoke Alarm installation vary from state to state
and from region to region. Check with your local Fire Department for current requirements in
your area. It is recommended AC or AC/DC units be interconnected for added protection.
Recommended Placement
Smoke Alarm
One on every level and
in every bedroom
Carbon Monoxide
One on every level and
in every bedroom
Fire Extinguisher
One on every level, plus
kitchen and garage
BEDROOM
LIVING ROOM
BASEMENT
HALLWAY
BEDROOM
KITCHEN
GARAGE
27
Regulatory Information
Federal Communications Commission (FCC) Compliance Statement
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
!
WARNING: Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
RF Exposure Information: This equipment complies with FCC radiation exposure limits set forth for
an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency
exposure limits, human proximity to the antenna shall not be less than 20cm during normal operation.
28
Industry Canada (IC)
Compliance Statement
This device complies with Industry Canada License-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type
and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential
radio interference to other users, the antenna type and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
29
Modular Devices FCC and Industry
Canada Compliance Statements
OEM Responsibilities to comply with FCC and Industry Canada Regulations
The BLEMOD1 Module and AW-CU300 Module have been certified for integration
into products only by OEM integrators under the following condition:
1.
The transmitter module must not be co-located or operating in
conjunction with any other antenna or transmitter.
As long as the condition above is met, further transmitter testing will not be required. However, the OEM
integrator is still responsible for testing their end-product for any additional compliance requirements
required with this module installed (for example, digital device emissions, PC peripheral requirements, etc.).
IMPORTANT: In the event that these conditions cannot be met (for certain configurations or co-
!
location with another transmitter), then the FCC and Industry Canada authorizations are no longer
considered valid and the FCC ID and IC Certification Number cannot be used on the final product.
In these circumstances, the OEM integrator will be responsible for re-evaluating the end product
(including the transmitter) and obtaining a separate FCC and Industry Canada authorization.
End Product Labeling
The BLEMOD1 Module and AW-CU300 Module are labeled with their own FCC ID and IC Certification Number.
If the FCC ID and IC Certification Numbers are not visible when the module is installed inside another device,
then the outside of the device into which the module is installed must also display a label referring to the
enclosed module. In that case, the final end product must be labeled in a visible area with the following:
“Contains Transmitter Modules FCC ID: M7U-BT1IOT and FCC ID: TLZ-CU300”
“Contains Transmitter Modules IC: 10190A-BT1IOT and IC: 6100A-CU300”
Or
“Contains FCC ID: M7U-BT1IOT and FCC ID: TLZ-CU300”
“Contains IC: 10190A-BT1IOT and IC: 6100A-CU300”
The OEM of the BLEMOD1 Module and AW-CU300 Module must only use the approved
antenna(s) listed above, which have been certified with this module. The OEM integrator has
to be aware not to provide information to the end user regarding how to install or remove this
RF module or change RF related parameters in the user manual of the end product.
To comply with FCC and Industry Canada RF radiation exposure limits for general population, the antenna(s) used
for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
30
Special Compliance Considerations
This Smoke Alarm is suitable for use in apartments, condominiums, townhouses, hospitals, day care facilities,
health care facilities, boarding houses, group homes and dormitories provided a primary fire detection system
already exists to meet fire detection requirements in common areas like lobbies, hallways, or porches. Using this
Smoke Alarm in common areas may not provide sufficient warning to all residents or meet local fire protection
ordinances/regulations.
This Smoke Alarm alone is not a suitable substitute for complete fire detection systems in places housing many
people—like apartment buildings, condominiums, hotels, motels, dormitories, hospitals, health care facilities,
nursing homes, day care facilities, or group homes of any kind. It is not a suitable substitute for complete fire
detection systems in warehouses, industrial facilities, commercial buildings, and special-purpose non-residential
buildings which require special fire detection and alarm systems. Depending on the building codes in your
area, this Smoke Alarm may be used to provide additional protection in these facilities. In new construction,
most building codes require the use of AC or AC/DC powered Smoke Alarms only. In existing construction,
AC, AC/DC, or DC powered Smoke Alarms can be used as specified by local building codes. Refer to NFPA
72 (National Fire Alarm and Signaling Code) and NFPA 101 (Life Safety Code), local building codes, or consult
your Fire Department for detailed fire protection requirements in buildings not defined as “households”.
HUD MAP Program: Certain HUD battery powered Smoke Alarm applications, especially
those that fall under HUD 223(f) MAP (Multi-family Accelerated Processing), may require
a 10 Year sealed tamper resistant battery. This alarm meets that requirement.
General Limitations for Smoke/CO Alarms
This Smoke/CO Alarm is intended for residential use. It is not intended for use in industrial applications where
Occupational Safety and Health Administration (OSHA) requirements for Carbon Monoxide Alarms must be met.
The Smoke Alarm portion of this device is not intended to alert hearing impaired residents. Special purpose
Smoke Alarms should be installed for hearing impaired residents (CO Alarms are not yet available for the
hearing impaired).
Smoke/CO Alarms may not waken all individuals. Practice the escape plan at least twice a year, making sure
that everyone is involved – from kids to grandparents. Allow children to master fire escape planning and practice
before holding a fire drill at night when they are sleeping. If children or others do not readily waken to the sound
of the Smoke/CO Alarm, or if there are infants or family members with mobility limitations, make sure that
someone is assigned to assist them in fire drill and in the event of an emergency. It is recommended that you hold
a fire drill while family members are sleeping in order to determine their response to the sound of the Smoke/
CO Alarm while sleeping and to determine whether they may need assistance in the event of an emergency.
31
General Limitations for Smoke/CO Alarms (Continued)
Smoke/CO Alarms cannot work without power. Battery operated units cannot work if the batteries are missing,
disconnected or dead, if the wrong type of batteries are used, or if the batteries are not installed correctly. If the AC power is
cut off for any reason (open fuse or circuit breaker, failure along a power line or at a power station, electrical fire that burns
the electrical wires, etc.). If you are concerned about the limitations of battery or AC power, install both types of units.
This Smoke/CO Alarm will not sense smoke or CO that does not reach the sensors. It will only sense smoke or CO at the
sensor. Smoke or CO may be present in other areas. Doors or other obstructions may affect the rate at which CO or smoke
reaches the sensors. If bedroom doors are usually closed at night, we recommend you install an alarm device (Combination
CO and Smoke Alarm, or separate CO Alarms and Smoke Alarms) in each bedroom and in the hallway between them.
!
CAUTION: This device will only indicate the presence of carbon monoxide gas at the sensor.
Carbon monoxide gas may be present.
This Smoke/CO Alarm may not sense smoke or CO on another level of the home. Example: This alarm device,
installed on the second floor, may not sense smoke or CO in the basement. For this reason, one alarm device may not
give adequate early warning. Recommended minimum protection is one alarm device in every sleeping area, every
bedroom, and on every level of your home. Some experts recommend battery powered Smoke and CO Alarms be used
in conjunction with interconnected AC powered Smoke Alarms. For details, see “About Smoke Alarms” for details.
Smoke/CO Alarms may not be heard. The alarm horn loudness meets or exceeds current UL standards of 85 dB at 10
feet (3 meters). However, if the Smoke/CO Alarm is installed outside the bedroom, it may not wake up a sound sleeper
or one who has recently used drugs or has been drinking alcoholic beverages. This is especially true if the door is closed
or only partly open. Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or
closed doors. Noise from traffic, stereo, radio, television, air conditioner, or other appliances may also prevent alert
persons from hearing the alarm horn. This Smoke/CO Alarm is not intended for people who are hearing impaired.
The Alarm may not have time to alarm before the fire itself causes damage, injury, or death, since smoke
from some fires may not reach the unit immediately. Examples of this include persons smoking in bed,
children playing with matches, or fires caused by violent explosions resulting from escaping gas.
This Smoke/CO Alarm is not a substitute for life insurance. Though this Smoke/CO Alarm warns
against increasing CO levels or the presence of smoke, BRK Brands, Inc. does not warrant or imply
in any way that they will protect lives. Homeowners and renters must still insure their lives.
This Smoke/CO Alarm has a limited life. Although this Smoke/CO Alarm and all of its parts have passed many
stringent tests and are designed to be as reliable as possible, any of these parts could fail at any time. Therefore,
you must test this device weekly. The unit should be replaced immediately if it is not operating properly.
This Smoke/CO Alarm is not foolproof. Like all other electronic devices, this Smoke/CO Alarm has
limitations. It can only detect smoke or CO that reaches the sensors. It may not give early warning
of the source of smoke or CO is in a remote part of the home, away from the alarm device.
32
Troubleshooting Guide
App FAQ
If the App...
Problem...
You Should...
Is unable to be downloaded or installed.
You cannot download or install the app.
Contact Customer Service Team.
Alarm FAQ
If the Alarm...
Problem...
You Should...
Light flashes yellow and Horn sounds
three “chirps” every minute. Voice:
“Detector error. Please see manual or
call customer service” every 5 hours.
Malfunction Signal. Device is not working
properly and needs to be replaced.
Units under warranty should be returned
to manufacturer for replacement. See
“Limited Warranty” for details.
Horn sounds 5 “chirps” every minute.
End of Life Signal. Alarm
needs to be replaced.
Immediately replace and
deactivate the alarm.
White LED light turns off.
Alarm is running on battery back-up.
Check all connections or restore power.
Does not connect to your Wireless
/ Bluetooth or opportunity
missed for pairing.
Alarm will not pair or you would like to
reset the device to clear all settings.
Press the test button 5 times
to reset alarm and try to pair to
Wireless and Bluetooth again.
Carbon Monoxide Alarm ONLY:
CO Alarm goes back into alarm 4
minutes after you Silence it.
CO levels indicate a potentially
dangerous situation.
If you are feeling symptoms of CO
poisoning, evacuate your home and
call 911 or the Fire Department. Refer
to “What To Do If the CO Alarm
Sounds” on page 17 for details.
CO Alarm sounds frequently even
though no high levels of CO are
revealed in an investigation.
The CO Alarm may be improperly
located. Refer to “Where to
Install” on page 6 for details.
Relocate your Alarm. If frequent alarms
continue, have home rechecked for
potential CO problems. You may be
experiencing an intermittent CO problem.
Smoke Alarm ONLY:
Smoke Alarm sounds when
no smoke is visible.
Unwanted alarm may be caused by nonemergency source like cooking smoke.
Silence alarm on App or using unit
button; clean the alarm’s cover with a
soft, clean cloth. If frequent unwanted
alarms continue, relocate your alarm.
Alarm may be too close to kitchen,
cooking appliance, or steamy bathroom.
NOTE: This alarm contains new Wireless and HomeKit technology that may not be wirelessly compatible with previously branded Onelink wireless alarms.
If you have questions that cannot be answered by reading this manual, contact the Customer Service Team at [email protected] or 1 (833) ONE-LINK (1-833-663-5465)
33
Limited Warranty
BRK Brands, Inc., (“BRK”) the maker of First Alert ® brand products warrants that for a period of five years
from the date of purchase, this product will be free from defects in material and workmanship. BRK, at its
option, will repair or replace this product or any component of the product found to be defective during the
warranty period. Replacement will be made with a new or re-manufactured product or component. If the
product is no longer available, replacement may be made with a similar product of equal or greater value.
This is your exclusive warranty. This warranty is valid for the original retail purchaser from the date of initial
retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase is required to obtain
warranty performance. BRK dealers, service centers, or retail stores selling BRK products do not have the right
to alter, modify or any way change the terms and conditions of this warranty. This warranty does not cover
normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product,
use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration
by anyone other than BRK or an authorized service center. Further, the warranty does not cover Acts of God,
such as fire, flood, hurricanes or tornadoes. BRK shall not be liable for any incidental or consequential damages
caused by the breach of any express or implied warranty. Except to the extent prohibited by applicable
law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the
duration of the above warranty. Some states, provinces or jurisdictions do not allow the exclusion or limitation
of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above
limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also
have other rights that vary from state to state or province to province.
How to Obtain Warranty Service
Service: If service is required, do not return the product to your retailer. In order to obtain warranty service, contact
the Customer Service Team at [email protected] or 1 (833) ONE-LINK (1-833-663-5465).
To assist us in serving you, please have the model number and date of purchase available when calling.
For Warranty Service return to: 1301 Joe Battle, El Paso, TX 79936
Disposal: Waste electrical products should not be disposed of with regular household waste.
Please recycle where facilities exist. Check local requirements for disposal of Lithium powered
electronic devices. The Alarm should be deactivated before disposal. See page 14, “Permanently
Deactivating the Alarm”. You can also return your Alarm to us for disposal. For return address
see above. Please include a note confirming the product is being returned for disposal.
Communication distance between alarms may vary from home to home depending
on environment, construction materials and size of structure. The quantity of
alarm required will depend on these factors. See manual for details.
34
Copyright and Technical Specifications
©2018 BRK Brands, Inc. All rights reserved. Distributed by BRK Brands, Inc., Aurora, Illinois 60504.
BRK Brands, Inc. is a subsidiary of Newell Brands Inc. (NYSE:NWL). Printed in USA.
Apple HomeKit, Apple iPhone, iPad, iPad Air, and iPod touch are trademarks of Apple Inc., registered in the
U.S. and other countries. HomeKit is a trademark of Apple Inc. App Store is a service mark of Apple Inc.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and
any use of such marks by BRK Brands, Inc., is under license. Other trademarks and trade names
are those of their respective owners. Wi-Fi® is a registered trademark of Wi-Fi Alliance.
Controlling this HomeKit-enabled accessory automatically and away from home requires an
Apple TV with tvOS 10.0 or later or an iPad with iOS 10.0 or later set up as a home hub.
To control this HomeKit-enabled accessory, iOS 10.0 or later is recommended
35
©2018 BRK Brands, Inc. All rights reserved. • Distributed by BRK Brands, Inc.
BRK Brands, Inc. is a subsidiary of Newell Brands Inc. (NYSE:NWL)
3901 Liberty Street Road, Aurora, IL 60504-8122
Customer Service Team: 1 (833) ONE-LINK (1-833-663-5465)
www.onelink.firstalert.com • 10/18 • Printed in USA • M08-0541-164658