BEA Universal Remote Control User Guide


Add to my manuals
2 Pages

advertisement

BEA Universal Remote Control User Guide | Manualzz
UNIVERSAL REMOTE CONTROL
|
LZR-I30/S600
L Z R - I 3 0 / S 6 0 0 PA R A M E T E R S
UNIVERSAL REMOTE CONTROL TIPS
# O F A C T I V E D E T E C T I O N C U R TA I N S
T O C H A N G E O R Q U E S T I O N A PA R A M E T E R ,
S TA R T B Y P R E S S I N G T H E
AND FINISH
THE SESSION BY PRESSING
E X A M P L E C O N F I G U R AT I O N S
CURTAIN
C1
C2
C3
C4
CURTAIN IS INACTIVE ON BOTH FIELDS
C1 + C2 ARE ACTIVE ON SAFETY FIELD
C3 + C4 ARE ACTIVE ON OPTIONAL FIELD
CURTAIN IS ACTIVE ON OPTIONAL FIELD
C1 IS ACTIVE ON BOTH FIELDS
C2 + C3 ARE ACTIVE ON SAFETY FIELD
C4 IS INACTIVE
The distances between the curtains depends on the mounting height and side.
When mounted on the left, the distance between curtain C1 and curtain C4 is approximately 4 in. for every 3 ft (mounting height).
EXAMPLE: At 15 ft. mounting height, the distance between C1 and C4 is 20 in.
CURTAIN IS ACTIVE ON SAFETY FIELD
CURTAIN IS ACTIVE ON BOTH FIELDS
T O Q U E S T I O N A PA R A M E T E R , P R E S S
AFTER UNLOCKING AND CHOOSING A
PA R A M E T E R . C O U N T T H E L E D F L A S H E S .
CONSIDER USING AN ACCESS CODE
T O S E T A N A CCE S S COD E :
MOUNTING SIDE
left
ALL CURTAINS ARE ACTIVE ON BOTH FIELDS
right
left
WITH BACKGROUND
right
T O D E LE T E A N A CCE S S COD E :
center
WITHOUT BACKGROUND
V I R T U A L P U S H P L AT E :
UNCOVERED ZONE
F A C T O R Y D E F A U LT S :
2in
4in
6in
8in
A LW AY S F I N I S H A N A D J U S T M E N T S E S S I O N
BY LAUNCHING A SETUP:
10 i n
Increase in case of snow, dead leaves, etc.
TO TURN THE LEDs ON/OFF:
O U T P U T A C T I VAT I O N D E L AY
OFF
100ms
200ms
300ms
FOR VISIBLE LASER BEAMS:
400ms
500ms
600ms
700ms
800ms
900ms
The relays are triggered when the detection duration ≥ the selected time.
OPTIONAL FIELD WIDTH
I M M U N I T Y F I LT E R
indoor
outdoor
low
outdoor
med
OPTIONAL FIELD HEIGHT
outdoor
high
outdoor
low
indoor
FOR CRITICAL ENVIRONMENTS
(RAIN, SNOW, FOG)
outdoor
med
SAFETY FIELD WIDTH
outdoor
high
SAFETY FIELD HEIGHT
FOR CRITICAL OBJECTS
(BLACK CARS)
Choose between environment or object.
LZR TIPS
MINIMUM OBJECT SIZE
THE LZR-I30REQUIRES 10-35 V CLEAN DC POWER
(NON-RECTIFIED)
OFF
3in
4in
6in
8in
AFTER 30 MINUTES, THE SENSOR LOCKS ACCESS TO
O U T P U T C O N F I G U R AT I O N
THE REMOTE CONTROL SESSION. POWER CYCLE THE
SENSOR TO RECONFIGURE.
R1
A - NO
P - NC
P - NC
A - NO
A = active
P = passive
R2
P - NC
A - NO
P - NC
A - NO
NO = normally open
NC = normally closed
A BEA UNIVERSAL REMOTE IS REQUIRED TO
CONFIGURE THE LZR-I30.
24/7 Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: [email protected] | Tech Docs: www.beasensors.com
75.5867.03 REMOTE CONTROL INDUSTRIAL 20160211
Page 1 of 2
UNIVERSAL REMOTE CONTROL
|
FA L C O N & I S 4 0 S E R I E S
UNIVERSAL REMOTE CONTROL TIPS
M I C R O W A V E PA R A M E T E R S
T O C H A N G E O R Q U E S T I O N A PA R A M E T E R ,
S TA R T B Y P R E S S I N G T H E
AND FINISH
THE SESSION BY PRESSING
SENSITIVITY
XXS
XS
S
>
>
>
>
L
XL
XXL
6s
7s
8s
9s
T O Q U E S T I O N A PA R A M E T E R , P R E S S
AFTER UNLOCKING AND CHOOSING A
PA R A M E T E R . C O U N T T H E L E D F L A S H E S .
A C T I VAT I O N R E L AY H O L D T I M E
0.5 s
1s
2s
3s
4s
5s
CONSIDER USING AN ACCESS CODE
T O S E T A N A CCE S S COD E :
DETECTION MODE
bi
uni
bi = two-way detection
uni = one-way detection towards sensor
uni depart = one-way detection away from sensor
uni
depart
T O D E LE T E A N A CCE S S COD E :
REJECTION MODE
1
2
3
4
5
6
R E L AY C O N F I G U R AT I O N :
NOTES FACTORY DEFAULTS
1: DETECTION OF ALL KINDS OF TARGETS IN MOTION
2: DETECTION OF ALL KINDS OF TARGETS IN MOTION + INTERFERENCE IMMUNITY
3: LOW ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY
4: MEDIUM ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY
5: HIGH ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY
6: HIGHEST ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY
1-4
F A C T O R Y D E F A U LT S :
A LW AY S F I N I S H A N A D J U S T M E N T S E S S I O N
BY LAUNCHING A SETUP:
I N F R A R E D PA R A M E T E R S
FREQUENCY
low
high
low
medium
L E A R N T I M E E X P L A N AT I O N
IR IMMUNITY
IF AN OBJECT IS IN THE PRESENCE DETECTION FIELD AND REMAINS MOTIONLESS FOR LONGER
THAN THE PROGRAMMED LEARN TIME, THE SENSOR WILL ACCEPT THE OBJECT AS PART OF
ITS BACKGROUND/REFERENCE POINT AND WILL DROP THE DETECTION SIGNAL.
high
A U T O M AT I C L E A R N T I M E
30s
1 min
2 min
5 min
10 min
20 min
1h
1.5 h
2h
I R PAT T E R N S I Z E
1
DOOR
2
DOOR
**INFINITY (
∞
∞ ) WILL NEVER LEARN A NEW BACKGROUND**
I R TA R G E T S I Z E
3
DOOR
4
DOOR
5
DOOR
DOOR
DOOR
DOOR
DOOR
2x2
1x2
6
DOOR
7
DOOR
8
DOOR
1x1
3x2
3x3
4x4
9
DOOR
24/7 Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: [email protected] | Tech Docs: www.beasensors.com
Page 2 of 2
75.5867.03 REMOTE CONTROL INDUSTRIAL 20160211

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Configuration of BEA sensors without physical interaction
  • Simple and intuitive interface for parameter changes
  • Interrogation of sensor parameters for quick diagnostics
  • Access code protection for added security
  • Automatic or manual background learn time adjustment
  • Output activation delay customization for precise control

Related manuals

Frequently Answers and Questions

How do I activate the detection curtains?
To activate the detection curtains, use the remote control to access the 'Curtain' parameter and set the desired configuration.
What is the purpose of the access code?
The access code provides an additional layer of security, preventing unauthorized access to parameter adjustments.
How do I adjust the infrared immunity level?
To adjust the infrared immunity level, use the remote control to navigate to the 'IR Immunity' parameter and select the appropriate setting.
Can I use the remote control to change the output activation delay?
Yes, the output activation delay can be customized using the remote control by adjusting the 'Output Activation Delay' parameter.
How do I set the background learn time?
The background learn time can be set automatically or manually using the remote control by adjusting the 'Automatic Learn Time' parameter.

advertisement