- Industrial & lab equipment
- Electrical equipment & supplies
- Power generators
- Ford
- FG7750PE
- User manual
Ford 7,750/6,250-Watt Gasoline Powered Electric/Recoil Start Portable Generator User guide
Add to my manuals
27 Pages
Ford FG7750PE is a powerful portable generator with a rated wattage of 6250W and a maximum output of 7.75kVA. It is powered by a 420cc OHV, 4-stroke, air-cooled engine and has a 6.6-gallon fuel tank. The generator features multiple AC outlets, including 120V and 240V receptacles, for connecting various electrical devices. It also has a built-in fuel gauge and an automatic voltage regulator to ensure stable power output.
advertisement
Generator
OPERATOR’S MANUAL
MODEL#: FG7 750 P E
ITEM#: F2E 6 25E 991
Warning: The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
www.fordpower.cc
TABLE OF CONTENTS
Introduction.
............................................................................................................................................................................
3
Product Specifications.
................................................................................................................................................
3
Parts Ordering / Customer Service.
.............................................................................................................................
3
Safety Rules.
...........................................................................................................................................................................
4
Safety Symbols.
...........................................................................................................................................................
4
Safety Instructions .
.....................................................................................................................................................
4
Features.
...................................................................................................................................................................................
7
Assembly ................................................................................................................................................................................
9
Unpacking .
...................................................................................................................................................................
9
Packing List .
............................................................................................................................................................... 9
R e mov e S hippi ng B rac k et ..........................................................................................................................................
10
Attaching Wheels ......................................................................................................................................................
10
Installing support leg ...................................................................................................................................................
10
Installing the handles ...................................................................................................................................................
11
Attaching battery cable ..............................................................................................................................................
11
Adding Oil/Checking engine oil ...................................................................................................................................
12
Adding Fuel.
...............................................................................................................................................................
13
Connecting Generator to an Electrical System.
........................................................................................................
13
Operation ..............................................................................................................................................................................
14
Grounding the Generator .
............................................................................................................................................
14
How to Start Engine.
..................................................................................................................................................
14
How to Stop Engine.
..................................................................................................................................................
15
Receptacles and Extension Cords.
.............................................................................................................................
15
Don’t Overload Generator.
..........................................................................................................................................
16
Wattage Reference Guide.
.........................................................................................................................................
17
Cold Weather Operation.
...........................................................................................................................................
18
Maintenance .
..........................................................................................................................................................................
19
Maintenance Schedule .
.............................................................................................................................................
19
Changing Oil .
............................................................................................................................................................
20
Engine Maintenance .
.................................................................................................................................................
21
Maintaining Fuel Valve.
..............................................................................................................................................
22
How to Store .
...........................................................................................................................................................
23
Troubleshooting .
..................................................................................................................................................................
24
Diagrams.
................................................................................................................................................................................
25
Warranty .
................................................................................................................................................................................
26
INTRODUCTION
Thank you for purchasing this superior quality portable generator from Ford Power Equipment. When operating and maintaining this product as instructed in this manual, your generator will give you many years of reliable service.
Product Specifications:
This generator is an engine-driven, revolving field, alternating current (AC) portable generator. It is designed to supply power outages.
AC Output
Rated Wattage
Rated Voltage
Rated Frequency
Rated Ampere
6 2 50W (6.25kW)
120V/240V
60Hz
5 2 A / 2 6
Engine
Rated Output
Maximum Output
6.25kVA
7 .75
kVA
420cc OHV, 4 Stroke, Air Cooled
Engine Oil 10W30 - 38oz (1 .1
L)
Fuel Tank 6.6 Gal (25L) Unleaded Gasoline
A
The emissions control system for this generator is compliant with all standards set by the U.S. Agency.
How to contact us:
To order parts, receive warranty assistance, or other services inquiries, you can contact us by internet at www.fordpower.cc
PULSAR PRODUCTS INC
2051 S Lynx Place
Ontario, California, U.S.A 91761
Record the following information bellow for service or warranty assistance.
Date of Purchase:
Model Number:
Item Number:
Serial Number:
SAVE THIS MANUAL FOR FUTURE REFERENCE
This manual contains important information regarding safety, operation, and maintenance.
3
SAFETY RULES
Safety Symbols
WARNING!
CAUTION!
Indicates a potentially hazardous situation which could result in serious injury or death if not avoided.
Indicates a potentially hazardous situation which could result in damage to equipment or property.
Toxic Fumes Risk of fire Risk of explosion
Risk of electric shock Hot surface Lifting hazard
Safety Instructions
The manufacturer cannot anticipate every possible hazardous circumstance that the user may encounter. Therefore, the warnings in this manual, on tags, and on affixed decals are not all-inclusive. To avoid accidents, the user must understand and follow all manual instructions and use common sense.
WARNING!
Read and understand this manual in its entirety before operating this generator. Improper use of this generator could result in serious injury or death.
WARNING!
Do not operate indoors or in a confined space preventing dangerous carbon monoxide gas from dissipating.
• Using a generator indoors WILL KILL YOU IN MINUTES !
• Carbon monoxide gas is a poisonous, odorless gas that can cause headache, confusion, fatigue, nausea, fainting, sickness, seizures, or death. If you start to experience any of these symptoms, IMMEDIATELY get fresh air and seek medical attention.
Never use indoors, in a covered area, or in a confined space, even if doors and windows are open.
•
•
• Install a battery operated carbon monoxide alarm near bedrooms.
Keep exhaust from this unit from entering a confined area through windows, doors, vents, or other openings.
• When working in areas where vapors could be inhaled, use a respirator mask according to all of its instructions.
WARNING!
Engine exhaust contains chemicals that lead to cause cancer and birth defects.
•
Always wash hands after handling generator.
WARNING!
To reduce the risk of serious injury, avoid attempting to lift the generator alone.
4
SAFETY RULES
WARNING!
Never exceed generator’s wattage / amperage capacity. This could damage the generator and / or connected electrical devices.
• Check operating voltage and frequency requirements of all electrical devices prior to plugging them into the generator.
WARNING!
Never start or stop engine with electrical devices plugged in to the receptacles. Failure to do so could damage the generator and / or connected electrical devices.
• Always start the engine and let it stabilize before connecting any electronic devices.
• Disconnect all electronic devices before stopping the engine.
WARNING!
Starter and other moving parts can catch on clothing, jewelry, and hair.
• Do not wear loose clothing or gloves.
• Remove jewelry or anything else that could be caught in moving parts.
• Tie back or wear protective head covering to contain long hair.
WARNING!
Keep engine away from flammable objects and other hazardous materials.
•
•
•
The fuel and its vapors used to power this unit are highly flammable and could explode resulting in serious injury or death.
Never fill or drain fuel tank indoors.
Never overfill fuel tank. If fuel spills, move the unit at least 30 feet away from the spill and wipe up any remaining fuel on the unit before starting the engine.
• Never smoke while operating or fueling this unit.
• Never operate or store this unit near an open flame, heat, or any other ignition source.
• Generator should have at least 5 feet of clearance from buildings or other equipment during operation.
• Keep engine free of grass, leaves, or grease which are flammable.
• When adding or draining fuel, unit should be turned off for at least 2 minutes to cool before removing fuel cap. If unit has been running then the fuel cap is under pressure, remove slowly.
• To keep fuel from spilling, secure unit so it cannot tip while operating or transporting.
• When transporting unit, disconnect the spark plug wire and make sure the fuel tank is empty with the fuel shutoff valve turned to the off position.
WARNING!
Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which could result in injury.
• To avoid recoil, pull starter cord slowly until resistance is felt, then pull rapidly.
WARNING!
Avoid contacting hot areas of this unit.
• Use caution around the muffler, cylinder, and other engine parts as they can be extremely hot.
• Allow hot components to cool before touching.
5
SAFETY RULES
WARNING!
This generator produces a very high voltage which could result in burns or electrocution causing serious injury or death.
• Never handle the generator, electronic devices, or any cord while standing in water, while barefoot, or when hands or feet are wet.
• Always keep the generator dry. Never operate generator in rain or under wet conditions.
• Use a ground fault circuit interrupter (GFCI) in a damp or highly conductive area, such as metal decking or steel work.
• Never plug electronic devices into generator having frayed, worn, or bare wires. Never touch bare wires or make contact with receptacles.
Never permit a child or unqualified person to operate generator. Keep children a minimum of 10 feet away from the •
• generator at all times.
• If using the generator for back up power, notify the utility company.
If connecting generator to a building’s electrical system for standby power, you must use a qualified electrician to install a transfer switch. Failure to isolate the generator from the power utility could result in serious injury or death to electric utility workers.
WARNING!
Generator must be properly grounded to prevent electrocution.
• Only operate generator on a level surface.
• Always connect the nut and ground terminal on the frame to an appropriate ground source.
WARNING!
Never modify this unit in any way or modify governed speed.
• Increasing governing speed is dangerous which can result in personal injury and / or damaged equipment.
• Decreasing governing speed adds an excessive load and can damage equipment.
• Only when operating at the preset governing speed will this generator will supply the correct rated frequency and voltage.
WARNING!
Only use this unit as intended or serious injury or death could result.
• Do not bypass any safety device. Moving parts are covered with guards. Make sure all protective covers are in place.
• Never transport or make adjustments to this unit while it is running.
• Never insert objects through cooling slots.
WARNING!
Never operate this unit if there are any broken or missing parts and only use Ford Power
Equipment replacement parts specifically designed for this unit.
•
•
• Improper treatment of generator can damage the unit and shorten it’s life.
Always repair this unit as specified in this manual. If you have any questions contact your dealer or consult a qualified service center.
Shut generator off if electrical output is missing, unit vibrates excessively or begins to smoke, spark or emit flames.
PROP 65 WARNING: This product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm.
6
FEATURES
A
G
F
E
D
B
C
A - START/ON/OFF Switch
B -
C -
Hour Meter
Main Circuit Breaker
D - Circuit Protectors
E -
F-
G -
Two 120 V GFCI duplex Receptacles .
120 Volt AC, 30 Amp twist lock receptacle (NEMA L5-30).
120 / 240 Volt AC, 30 Amp twist lock receptacle (NEMA L14-30).
7
FEATURES
K
L
M
O
N
J
I
H
H - Fuel Gauge
I - Fuel Tank Vapor Vent
J - Generator Frame
K - Choke Lever
L - Air Filter
M - Handles & Grips
N - Oil Drain Plug
O - Support Leg (Foot)
P - Fuel Tank
Q - Fuel Fill Cap
R - Fuel Valve (ON/OFF)
S - Recoil Starter Grip
T - Oil Fill (Dipstick)
U -
Battery
VNo Flat Foam Filled Tires
R
S
T
U
V
P
Q
8
ASSEMBLY
Unpacking
1. Place box on a level surface.
2. Remove all items from box except the generator. Make sure all items listed on the packing list are included and not damaged.
Packing List
Check all loose parts to the following list. Contact your dealer if any loose parts are not included.
Description
Generator
Quick Start Guide
4-Cycle engine oil (SAE10W-30)
Toolkit
Spark Plug Wrench
Phillips screwdriver
10mm Combination Wrench
Funnel
Handles
Bushings (Flanged)
1
1
1
1
Qty
1
2
4
2
1
Description
M8 x 45mm Hex Bolts for Handle
M8 Flanged Nuts for Handle
Wheel
Axle
Hair pin
Hub Cap
Screw, Self-Tapping
Washer
Supporting Leg
M8 x 16mm Hex Bolts for Foot
M8 Flanged Nuts for Foot
2
2
2
2
1
2
2
2
2
Qty
2
2
+ +
+ + + + +
10W30
OIL
( + +
8 - 10
10 - 13
)
9
ASSEMBLY
Remove Shipping Bracket (See fig 1)
• Remove and discard the two RED shipping bracket s and mounting hardware before starting the Generator.
Attaching Wheels (See fig 2)
• Parts needed - 2 wheels, 2 axles, 2 hair pins, 2 washers, 2 hub caps and 2 self-tapping screws.
• Raise or tilt generator so you can slide the wheel axle pin into the wheel, the washer, the wheel mounting hole located on the side of the frame.
• Secure the wheel assembly by reinserting a hair pin through hole at the end of the wheel axle and pressing until it locks into place.
• Install hub cap to the wheel until “Click”. Install self-tapping screw, until the screw is snug.
• Repeat process on the other side of the generator to install the second wheel.
Fig 1 Fig 2
Installing Support Leg (See fig 3)
•
• Parts needed - Support leg & M8 screw (2).
Raise the front end of the generator high enough to gain access to the bottom of the frame. Securely position props underneath to support.
• Line up holes on the support leg bracket to the holes on the front of the generator frame.
• Attach the support leg using M8 screws (2).
Fig 3
10
Fig 4
ASSEMBLY
Attaching Battery Cable (See fig
4
)
• Parts needed - Black and Red battery cable
• The Red (+) Connector should be attached to the battery first.
• Remove the screw from the battery terminal.
• Place the screw through the eyelet and tighten the screw and make sure the terminal will not touch any part of the frame.
• Install the Red protection boot.
• Repeat these steps for the Black (-) Terminal.
Intalling The Handles (See fig 5
)
Fig 5
Fig 6
CAUTION!
Be careful not to short across the terminals when installing. Shorting the terminals together can cause sparks, damage to the battery or generator, or even burns or explosions.
Cover the terminals with the rubber covers
When removing the battery for replacement: Remove the nut and bolt first from the negative (Black) post, then from the positive (Red) post, being careful not to short across the terminals. Always abide by the safety warnings provided with the battery. Remove the battery and dispose of it according to your local and state regulations.
WARNING!
Battery posts, terminals, and accessories contain lead and lead compounds known to cause cancer and reproductive harm.
• Always wash hands after touching battery.
11
ASSEMBLY
NON-SPILLABLE
SEALED BATTERY
This is a ready filled, activated sealed battery.
Never remove strip.
Refer to owner’s manual l or instruction sheet for charging procedures.
SHIELD
EYES.
EXPLOSIVE
GASES CAN
CAUSE BLINDNESS
OR INJURY
!
DANGER/POISON
FLUSH EYES
IMMEDIATLEY
WITH WATER
NO
SPARKS
FLAMES
SMOKING
SULFURIC
ACID
CAN CAUSE
BLINDNESS OR
SEVERE BURNS
WARNING!
PROPOSITION 65
WARNING
Wear Eye Protection
Never Reverse Pole Connections
Never turn the battery upside down
DO NOT Smoke near the battery
Battery posts,terminals,and related accessories contain lead and lead compounds,chemicals known to the
State of California to cause cancer and reproductive harm.
Wash hands after handling.
If electrolyte contact the skin wash the area immediately with clean water
If you get electrolyte contact with your eye,rinse immediately with clean water and seek medical attention
NOTICE:
If the Generator is stored for over six months the battery will need to be removed and charged
Pb
Antidotes for battery acid
CONTACT TREATMENT
External
Internal
Eyes
Flush with water.
Drink large quantities of milk or water, followed by milk of magnesia, vegetable oil or beaten eggs. Get immediate medical attention.
Flush with water. Get immediate medical attention.
Adding / Checking Engine Oil (See fig 7)
•
• Place generator on a level surface.
Remove the crankcase dipstick to ensure you do not overfill the engine.
• Insert a funnel into the crankcase dipstick hold and carefully add 4-Cycle engine oil (SAE10W- 30) to empty reservoir until oil reaches the outer edge of the oil fill hole (crankcase dipstick hole).
• Be sure to replace dipstick before attempting to start the engine.
• To check oil, set generator on a level surface, wipe dipstick clean, then reinsert dipstick without rethreading.
12
ASSEMBLY
Adding Fuel (See fig 8)
• Set generator on a clean and level surface in an area that is well ventilated.
• Remove fuel cap.
• Insert a funnel into the fuel tank and carefully pour gasoline into the tank until fuel level reaches 1 ½ inches below the top of the neck. Be careful not to overfill the tank to provide space for fuel expansion.
CAUTION!
You must add oil before first operating this generator. Always check oil level before each operation.
DO NOT USE E15 OR E85 FUEL IN THIS UNIT. IT IS A VIOLATION OF FEDERAL LAW AND
WILL DAMAGE THE UNIT AND VOID YOUR WARRANTY.
10W30 OIL
Unleaded
Gasoline
Fig 7 Fig 8
Connecting Generator to an Electrical System
• If connecting generator to a building’s electrical system for standby power, you must use a qualified electrician to install a transfer switch. The power from the generator must be isolated from the circuit breaker or alternative power source.
The connection must comply with all electrical codes and applicable laws.
WARNING!
This generator produces a very high voltage which could result in burn or electrocution causing serious injury or death.
• Never handle the generator, electronic devices, or any cord while standing in water, while barefoot, or when hands or feet are wet.
• Always keep the generator dry. Never operate generator in rain or under wet conditions.
• Use a ground fault circuit interrupter (GFCI) in a damp or highly conductive area, such as metal decking or steel work.
• Never plug electronic devices into generator having frayed, worn, or bare wires. Never touch bare wires or make contact with receptacles.
Never permit a child or unqualified person to operate generator. Keep children a minimum of 10 feet away from the • generator at all times.
• If using the generator for back up power, notify the utility company.
• If connecting generator to a building’s electrical system for standby power, you must use a qualified electrician to install a transfer switch. Failure to isolate the generator from the power utility could result in serious injury or death to electric utility workers.
1 3
OPERATION
Grounding the Generator (See fig 9)
The ground terminal located on the back of the generator frame must always be used to connect generator to a driven ground rod. Connect the ground terminal to the driven ground rod with a No 8 AWG (American Wire Gauge) copper wire. The wire connects to the terminal between the lock washer and nut. Tighten the nut securely to ensure proper connection. Grounding the generator protects you from electric shock that results from a build up of static electricity or undetected ground faults.
Fig 9
WARNING!
Generator must be properly grounded to prevent electrocution.
• Only operate generator on a level surface.
• Always connect the nut and ground terminal on the frame to an appropriate ground source.
How to Start Engine (See fig 10-12)
•
• Place generator on a level surface. All electrical loads MUST be disconnected from generator.
Turn fuel valve to the “ON” position. (See fig 10)
• Slide the choke lever to the “Choke” position. (See fig 11) SKIP THIS IF THE ENGINE IS WARM OR HOT.
• For electric start, Push and hold the engine START/ON/OFF switch in the “START” position. Do not hold the START/
ON/OFF switch in the “Start” position for more than 15 seconds. Allow 1 minute between starting attempts. (See fig1 2 )
• For manual start, turn the engine START/ ON/OFF switch to the “ON” position. Pull the recoil handle (starter cord) slowly until resistance is felt, then pull rapidly. (See fig 13)
• Let engine run for several seconds and then gradually, as engine warms up, slide the choke lever towards the “RUN” position until the choke is fully slid to the “RUN” position. (See fig 14)
CHOKE
CHOKE LEVER
RUN
START
Fig 12 E lectric Start Fig 10
START
Fig 11
SKIP THIS IF THE ENGINE IS
WARM OR HOT.
WAIT
5sec
CHOKE
CHOKE LEVER
RUN
Fig 1 3 Recoil Start Fig 1
1 4
4
OPERATION
WARNING!
Never start or stop engine with electrical devices plugged in to the receptacles. Failure to do so could damage the generator and / or connected electrical devices.
• Always start the engine and let it stabilize before connecting any electronic devices.
• Disconnect all electronic devices before stopping the engine.
WARNING!
Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which could result in injury.
• To avoid recoil, pull starter cord slowly until resistance is felt, then pull rapidly.
Battery Charger for Electric Starter
Keep the generator battery fully charged and ready to use to avoid the need to use the recoil starter to start the generator manually.
How to Stop Engine (See fig 15
-17
)
• All loads MUST be disconnected from the generator. Never start or stop the engine with electrical devices plugged in to the receptacles.
• Turn the engine START/ ON/OFF switch to the “OFF” position.
• Turn the fuel valve to the “OFF” position.
2
START
Fig 15 Fig 16 Fig 17
Receptacles and Extension Cords
Only use high quality, well-insulated, grounded extension cords in good condition with generator receptacles. Follow each load manufacturer’s power rating recommendation when selecting receptacle and extension cord.
This generator is equipped with the following receptacles:
• Two 120 V GFCI duplex Receptacles .
• 120 Volt AC, 30 Amp twist lock receptacle (NEMA L5-30).
• 120 / 240 Volt AC, 30 Amp twist lock receptacle (NEMA L14-30).
120 Volt AC, 20 Amp receptacle
• This receptacle has a 20 Amp push-to reset circuit breaker to protect against overload.
• Each socket is rated to operate 120 Volt, AC, single phase, 60Hz loads requiring up to 2400 watts (2.4 kW) at 20 Amps.
• Use extension cords having a minimum rating of 125 Volts AC, 20 Amps.
• L5-30 is rated to operate 120 Volt, AC, single phase, 60Hz loads requiring up to 3600 watts (3.6 kW) at 30 Amps.
120 / 240 Volt AC, 30 Amp locking receptacle
• This receptacle is rated to operate 120 Volt, AC, single phase, 60Hz loads requiring up to 3600 watts (3.6 kW) at 30
Amps. It is also rated to operate 240 Volt AC, single phase, 60Hz loads requiring up to 7,200 watts (7.2 kW).
• Use a NEMA L14-30 plug with this receptacle.
• Use a 4-wire cord rated for 240 Volts AC, 30 Amps to the plug. You can use the same 4-wire cord to operate a 120 Volt load.
1 5
OPERATION
CAUTION!
Do not connect 3-phase loads to generator.
Extension Cord Selection
Refer to the below table to ensure the extension cord used has the capacity to carry the required load. If the size of the cable is inadequate it can cause a voltage drop, which can damage the electrical device and cord.
Current
(Amps)
10
15
20
25
30
2.5
5
7.5
Load (Watts)
230V
600
1200
1800
2400
3800
4800
6000
7200
X
X
Maximum Cord Length
#8 Wire #10 Wire
X
1000 ft.
500 ft.
350 ft.
X
X
175 ft.
150 ft.
125 ft.
250 ft.
150 ft.
125 ft.
100 ft.
65 ft.
#12 Wire
600 ft.
300 ft.
200 ft.
150 ft.
100 ft.
75 ft.
X
X
#14 Wire
375 ft.
200 ft.
125 ft.
X
X
100 ft.
65 ft.
X
#16 Wire
250 ft.
125 ft.
100 ft.
X
X
50 ft.
X
X
Moving the Generator
• Disconnect any electronic devices from generator then turn generator off.
• Turn fuel valve to the “OFF” position.
• Tilt generator until it balances on wheels. Roll machine to desired location.
• If the generator must be carried, fold handle to the down position. Never lift or carry generator by its handle.
CAUTION!
This product is heavy and requires several people to lift. Lift and lower with your legs by bending at the knees, not your back, to avoid injury.
Don’t Overload Generator
Make sure you can supply enough rated watts and surge watts for all electronic devices connected to the generator. Rated watts refer to the power a generator must supply to keep a device running. Surge watts refer to the power a generator must supply to start an electronic device. This power surge for starting a device usually lasts between 2-3 seconds but this additional output must be taken into account when selecting the electronic devices you plan to attach to the generator. To prevent overloading the generator take the following steps:
1. Add up the total rated wattage of all electronic devices that will be connected to the generator simultaneously.
2. Estimate surge watts by adding the item(s) with the highest output (it is unnecessary to calculate the surge output for all devices as they should be connected one at a time).
3. Add the Surge Watts to the total Rated Watts in step 1. Keep total load within generator’s power capacity.
Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation, and +/- 3 Hz frequency variation from the generator name plate ratings. To reduce the risk of damage, always have an additional load plugged into the generator if solid state equipment (such as television set) is used. A power line conditioner is recommended for some solid state applications.
1 6
OPERATION
Wattage Reference Guide
(Wattages listed are just approximations. Check electronic device for actual wattage)
Essentials
75W Light Bulbs
Rated Watts Surge Watts
75 each 75 each
18 CU Ft Refrigerator / Freezer 800
Furnace Fan ( ⅓ HP)
Sump Pump ( ⅓ HP)
Water Pump ( ⅓ HP)
Heating/Cooling
800
1000
1000
Dehumidifier
Table Fan
650
800
2200
2350
2000
3000
800
2000
Window AC (10k BTU)
Central Air (10k BTU)
Electric Blanket
Space Heater
1200
1500
400
1800
3600
6000
400
1800
Kitchen
Blender
Toaster (2 slice)
Coffee Maker
Electric Range (1 element)
Dishwasher
Electric Oven
Electric Water Heater
Laundry Room
Iron
Washing Machine
Gas Clothes Dryer
Electric Clothes Dryer
300
1000
1500
1500
1500
3410
4000
1200
1150
700
5400
900
1600
1500
1500
3000
3410
4000
1200
3400
2500
6750
Bathroom
Hair Dryer
Curling Iron
Family Room
X-Box or Play Station
AM/FM Radio
VCR
Color TV (27”)
Home Office
Fax Machine
Air Compressor
Other
Home Security System
Garage Door Opener ( ⅓ HP)
Rated Watts Surge Watts
1250
1500
40
100
100
500
Personal Computer (17” Monitor)
Laser Printer
Copy Machine
Power Tools
65
800
950
1600
1000W Quartz Halogen Work Light 1000
Airless Sprayer ( ⅓
Reciprocating Saw
HP) 600
960
Circular Saw (7 ¼”)
Miter Saw (10”)
1400
1800
Table/Radial Arm Saw
Electric Drill (½ HP, 5.4 Amps)
Hammer Drill
2000
600
1000
1600
500
750
0
0
0
100
100
500
0
0
0
0
0
1200
0
2300
1800
2000
900
3000
4500
500
750
WARNING!
Never exceed generator’s wattage / amperage capacity. This could damage the generator and / or connected electrical devices.
• Check operating voltage and frequency requirements of all electrical devices prior to plugging them into the generator.
1 7
OPERATION
Hour Meter (See Fig 16)
The digital hour meter operates whenever the engine is running and keeps track of how many hours the unit has been used.
Use this meter along with the manual to determine when and what type of service on the unit is needed. The display will show the word “LUBE” at the first 25 hours of operation and again at every 100 hours of operation after.
Fig 16
•
•
•
Power Management
Start engine without anything connected to generator.
When engine has stabilized, plug in and turn on first load. It is strongly recommended to plug in devices with the largest output first and the smallest output last to help prevent overloading the generator.
Allow generator output to stabilize (engine and attached devices run evenly) before plugging in the next load.
Cold Weather Operation
Under humid conditions where temperatures drop to 40ºF (4ºC) the carburetor and/or crankcase breather system may begin to freeze. To prevent icing take the following steps:
1. Replace any old fuel with clean, fresh fuel.
2. Use synthetic 5W-30 or SAE 5W-30 engine oil. Check oil daily or after every 8 hours of use.
3. Turn fuel valve to the open position.
4. Ensure generator is serviced according to the maintenance schedule under “Maintenance” section of manual.
5. Shelter unit from elements.
1 8
MAINTENANCE
Creating a Temporary Cold Weather Shelter
1.
2.
In an emergency, the original shipping carton can be used as a temporary shelter. The shelter should hold enough heat created by the generator to prevent icing.
Cut off all flaps.
Cut off one of the long sides of the carton to expose the units muffler and exhaust. Do not enclose the muffler / exhaust side of the generator.
Slide carton over generator. If necessary, remove the wheel assembly for fit.
3.
4. Maintain 5 feet of clearance between the open side of box and other objects. The exposed side of the box should face away from the wind and elements.
5. Remove shelter when temperatures reach 40ºF (4ºC).
Regular maintenance will extend the life of this generator and improve its performance. The warranty does not cover items that result from operator negligence, misuse, or abuse. To receive full value from the warranty, operator must maintain the generator as instructed in this manual, including proper storage.
WARNING!
Before inspecting or servicing this machine, make sure the engine is off and no parts are moving. Disconnect the spark plug wire and move it away from the spark plug.
Pre-Operation Steps
•
•
Before starting the engine, perform the following pre-operation steps:
• Check the level of the engine oil and the fuel tank level.
Make sure the air filter is clean.
Remove any debris that has collected on the generator and around the muffler and controls. Use a vacuum cleaner to pick up loose debris. If dirt is caked on, use a soft bristle brush.
• Inspect the work area for hazards.
After Each Use
Follow the following procedure after each use:
• Shut off engine.)
• Store unit in a clean and dry area.
Maintenance Schedule
After First 5 Hours Change Oil
After 8 Hours or Daily Clean Debris
Check Engine Oil Level
Annually (25 hr Use) Check and Clean Air Cleaner
Change Engine Oil (Service more often under dirty or dusty conditions)
Check Muffler and Spark Arrester
Annually (100 hr Use) Service Spark Plug (Replace with NGK BP6ES, Champion N9YC or equivalent)
Service Fuel Valve
Inspect Muffler and Spark Arrester
Check and Clean Air Cleaner, Replace Air Filter
Clean Cooling System
1 9
MAINTENANCE
Changing Oil (See Fig 17)
• Run the Generator until the Engine is warm.
• Place generator on a level surface.
• Remove the crankcase dipstick.
• Place an oil pan underneath the oil drainage bolt to collect used oil.
• Remove the oil drainage plug and allow oil to drain completely.
• Reinstall oil drainage plug, tighten securely.
• Carefully add SAE 10W-30 to empty reservoir until the oil reaches the outer edge of the oil fill hole (Crankcase Dipstick hole).
• Replace crankcase dipstick.
Oil Fill & Dipstick
Oil drainage plug
Fig 17
•
•
Oil Recommendations
Do not use special additives.
Outdoor temperatures determine the proper oil viscosity for the engine. Use the chart to select the best viscosity for the outdoor temperature range expected.
F
104
86
68
50
32
14
-4
-22
*
*
*
C
40
30
20
10
0
-10
-20
-30
Note: * Below 40 F (4 C ) the use of SAE 30 will result in hard starting.
* * Above 80 F (27 C ) the use of 10W-30 may cause increased oil consumption.
Check oil level more frequently.
20
MAINTENANCE
CAUTION!
Used oil should be disposed of at an approved disposal site. See your local oil retailer for more information.
Air Filter (See Fig 18)
•
•
•
•
A dirty air filter will reduce the life span of the engine, make it difficult to start the engine, and reduce the unit’s performance.
To clean, remove the air filter cover.
Carefully pull the air filter out by lifting up along the edges.
Remove dirt from filter by tapping on it or having it blown out. Replace with new filter annually.
Reinstall air filter so that it seals and replace air filter cover.
Checking Spark Plug (See Fig 19)
• Disconnect the spark plug wire from the spark plug.
• Before removing the spark plug, clean the area around its base to prevent debris from entering the engine.
• Clean carbon deposits off the electrode with a wire brush.
• Check the electrode gap and slowly adjust to .700 mm - .80 mm (.028 - .031") if necessary.
• Reinstall spark plug and tighten to Torque 22.0 – 26.9 Nm (16-20 ft-lb).
• Reconnect spark plug wire.
• If spark plug is worn replace only with an equivalent replacement part. Spark plug should be replaced annually.
(BOSCH F7TC, NGK BP6ES, CHAMPION N9YC or Equivalent)
.700-.800mm
Fig 18 Fig 19
Spark Arrestor (See Fig 20)
• Inspect the spark arrestor for breaks or holes. Replace if necessary. To purchase a replacement spark arrestor contact
PULSAR customer service.
• Use a brush to remove carbon deposits from the spark arrestor screen as needed.
• To remove the spark arrestor: While the muffler is cool, loosen the locking clamp and slide the spark arrestor out of the muffler. Reverse this process to install it.
Cooling System
Cooling system should only be serviced by an authorized dealer.
2 1
MAINTENANCE
Carburetor Adjustment
The carburetor is low emission and is equipped with a non-adjustable idle mixture valve. If adjustment is needed contact an authorized dealer.
Replacing Fuel Filter (See Fig 21)
Occasionally the fuel filter may become clogged and need replacing. To purchase a replacement fuel filter contact PULSAR customer service or your local small Engine repair shop.
• Turn the fuel valve to the “OFF” position.
• Remove the fuel line from both sides of the filter by squeezing the ends of the retaining clip with pliers.
• Slide the fuel line off.
• Replace with new fuel filter.
• Reinstall fuel lines to new fuel filter.
• Turn the fuel valve to the “ON” position.
CAUTION!
Fuel tank must be empty before replacing fuel filter. Run unit until tank is empty, if needed, or inspect filter prior to fill-up.
Fig 20 Fig 21
Draining Fuel Tank and Carburetor
To help prevent gum deposits in the fuel system, drain the fuel from the tank and carburetor before storing the unit for long periods of time. This will help prevent starting problems in the future. If the unit is stored with fuel and the fuel becomes stale or turns gummy or to varnish the warranty does not cover this repair or service.
Draining the fuel tank
• Turn the engine OFF.
• Turn the fuel valve to the OFF position.
• Remove the fuel line that leads to the carburetor from the petcock by squeezing the ends of the hose clamps and sliding the fuel line off.
• If needed, install a fuel hose that will extend to a suitable fuel container large enough to catch the fuel being drained from the tank.
• Turn the fuel valve to the ON position.
• When the fuel has drained from the tank, close the fuel valve and reinstall fuel line securely on petcock.
2 2
MAINTENANCE
Draining the carburetor
• Turn the engine OFF.
• Turn the fuel valve to the OFF position.
• Position a suitable container under the carburetor drain screw to catch fuel; loosen the screw.
• Allow fuel to drain completely into container.
• Retighten drain screw.
CAUTION!
Consult your local hazardous waste management in your area for the proper way to dispose of used fuel.
Storage and Transportation of the Generator: (See Fig 2
2
)
• Remove any debris that has collected on the generator and around the muffler and control panel. Use a brush or vacuu m
to remove loose dirt.
• Inspect air cooling slots. Remove any debris if obstructed.
• For short-term storage, start generator once every 7 days.
• For semi-long term storage, add fuel stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system and carburetor .
• For long-term storage, drain the fuel.
• Store the generator indoors to prevent freezing.
• The generator must be Shipped, Run and Stored in the upright position as seen in this image.
Fig 22
Engine Long Term Storage:
• Remove the spark plug and pour about 1 teaspoon of 10W30 Engine oil into the spark plug hole. Reinstall the spark plug.
With the ON/OFF switch in the OFF position pull the recoil starter cord several time to coat the cylinder walls with oil.
• Slowly pull the recoil Starter until you feel the engine build compression (When you feel resistance). Leave the Engine in this state as this will prevent any corrosion on the cylinder walls if stored for a long period of time.
2 3
TROUBLESHOOTING
Problem
Engine is running, but AC output is not available
Engine runs well without load but bogs down when loads are connected
Engine will not start, shuts down during operation, or starts and runs rough.
Engine lacks power
Engine “hunts” or falters
Cause
1. Open circuit breaker
2. Poor connection
3. Defective cord set
4. Connected device is faulty
5. Fault in generator
1. Short circuit in connected device
2. Generator is overloaded
3. Clogged fuel filter
4. Engine speed is too slow
5. Short circuit in generator
1. ON/OFF switch set to “OFF”
2. Dirty Air filter
3. Clogged fuel filter
4. Stale fuel
5. Spark plug wire disconnected from
spark plug
6. Bad spark plug
7. Water in fuel
8. Fuel valve is in “OFF” position
9. Over choking
10. Low oil level
11. Rich fuel mixture
12. Intake valve stuck open or closed
13. Loss of engine compression
14. Dead battery
15. Engine has flooded
1. Generator is overloaded
2. Clogged fuel filter
3. Dirty Air filter
4. Engine needs servicing
Solution
1. Reset circuit breaker
2. Check and repair
3. Check and repair
4. Connect a device that is working
properly
5. Contact service department
1. Disconnect device
2. See pg 15 “Don’t overload
generator”
3. Clean or replace fuel filter
4. Contact service department
5. Contact service department
1. Turn switch to “ON”
2. Replace Air filter
3. Clean or replace fuel filter
4. Replace fuel
5. Reconnect spark plug wire
6. Replace spark plug
7. Drain fuel tank and replace fuel
8. Turn fuel valve to “ON” position
9. Turn off choke
10. Fill crankcase to proper oil level &
place generator on a level surface
11. Contact service department
12. Contact service department
13. Contact service department
14. Recharge or replace battery
15. Wait 5 minutes and recrank engine
1. See pg 15 “Don’t overload generator”
2. Clean or replace fuel filter
3. Replace Ai r f ilter
4. Contact service department
1. Choke was removed too soon
2. Clogged fuel filter
3. Carburetor is running too rich or too lean
1. Move choke to middle position until
engine runs evenly
2. Clean or replace fuel filter
3. Contact service department
department
2 4
DIAGRAMS
2 5
WARRANTY
Ford Power Equipment Limited 2 Year Warranty:
From the date of original purchase, Ford Power Equipment warrants to the original purchaser that each portable generator sold, shall be free from defect in material and workmanship for the items and time period set forth below. Ford Power
Equipment, at its discretion, agrees to repair or replace any defective part that upon examination, inspection, and testing by a Ford Power Equipment authorized service dealer, is found to be defective within the original warranty period. Ford Power
Equipment will also decide upon the use of new or rebuilt parts or comparable product. Any part or product that is replaced will be retained by Ford Power Equipment. This warranty period shall not be extended and any repaired product shall be warranted for the remaining period of the original warranty. The consumer is responsible, and shall prepay all transportation costs, including returning items to the factory or warehouse. This warranty is non-transferable and proof of purchase must be presented for requesting warranty service. If a proof-of-purchase receipt is not provided, the product’s shipping date by the manufacturer will be used to determine the warranty period.
Length of Warranty:
P ers on al use applicati on s of this p o rtable g e n erat o r are w arra n te d fo r 24 mon th o r 500 hrs usi ng ( Whiche v er c om es f irst). P r oof of purchase a nd ofm ai n te n a n ce m ust be pr ov i d e d .
• 6 Month - Limited comprehensive coverage on all generator components and labor.
• 12 Month - Limited coverage on generator engine and alternator components, parts only.
• 24 Month - Limited coverage on generator engine components, parts only.
“Personal use” means personal residential household use or recreational use by the retail consumer. “Commercial use” means all other uses including commercial, construction, or other income producing purposes. Once a generator has been used for commercial purposes, it shall thereafter be considered as a “commercial use” generator for the purposes of this warranty. Any portable generator used for commercial use, as rental equipment or for the purpose of primary power in place of utility, will not be covered under this warranty.
Consumer Responsibilities:
• Consumer is responsible for carefully reading and following all instructions in the owner’s manual. Any product that is damaged due to misuse or abuse will not be covered by this warranty.
• Consumer is responsible for all transportation costs to an authorized Ford Power Equipment Service Center. Unless
• otherwise requested, ground shipping will be applied for part shipment and customer will pay any additional charges for expedited shipments.
• Consumer is responsible for labor costs associated with warranted repairs twelve (12) months after the purchase date.
Labor rates will only be based on normal working hours.
Consumer is responsible for maintaining generator as specified in the owner’s manual. Documentation of this maintenance may be required to cover warranty requests.
• Consumer is responsible for presenting any problems with the generator to an authorized Ford Power Equipment
Service Center as soon as the problem exists. Warranted repairs will be completed in a reasonable period of time, not to exceed 30 days.
2 6
WARRANTY
What this Warranty Does Not Cover: • Normal wear: This warranty excludes normal wear items such as filters, spark plugs, gaskets, O-rings, adapter cord sets, wheels, and starting batteries.
• Maintenance: This warranty does not apply to tune-ups or routine maintenance and does not cover any adjustments or repairs not performed by an authorized repair facility.
• Misuse: This warranty does not apply if your product has failed due to abuse, misuse, neglect, using incorrect fuels or lubricants, overloading, overspeeding, improper maintenance, improper storage, unapproved modifications, or has been operated in any way contrary to the instructions found in the products owner’s manual.
• Adverse conditions: This warranty does not apply if your product has failed due to freezing, accident or natural disasters.
• Product shipment: This warranty does not apply to damage resulting from shipping, handling, or warehousing. Any damage claims to this product caused by shipment must be filed with freighter.
• Other exclusions: This warranty does not apply if your product has been sold “as is” or where the factory applied serial number has been removed. Refurbished, used, demonstration or floor models are not covered by this warranty.
Where Warranty is Valid:
For warranty coverage, this product must be purchased from an authorized Ford Power Equipment dealer and the warranty only extends to the original purchaser. Refurbished, used, demonstration, or floor models are not covered by this warranty.
Products purchased from on-line auction websites, such as ebay, are not covered under this warranty. Products used for commercial use are not covered under this warranty.
How to Obtain Warranty Service:
Take the original receipt and product to the place of purchase or mail the original receipt and product to the address found on the web site if purchased on-line. You can also locate your nearest Ford Power Equipment dealer for service or warranty questions by calling toll free at 1-888-863-7589 . Ford Power Equipment recommends you retain all of your receipts covering the purchase and maintenance of your Portable Generator, but will not deny you warranty coverage as long as proof of purchase or service can be obtained.
Ford Power Equipment’s obligation under this warranty is exclusively limited to product repair or replacement and shall not be liable for any incidental or consequential damages including, but not limited to, the expense of delivering product to and from a repair center, loss or damage to personal property, loss of revenue, telephone charges, loss of time, or inconvenience. Some states, provinces or jurisdictions do not allow the exclusion or limitation of incidental damages, so the above limitation may not apply to you. The warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.
Rev.A 11 / 11
2 7
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement