- Home
- Domestic appliances
- Large home appliances
- Water heaters & boilers
- Noritz
- GQ-C3259WX-FF US LP
- Specification
Noritz GQ-C2859WX-FF US NG EZ Series 9.8 GPM Residential Natural Gas Hi-Efficiency Indoor/Outdoor Tankless Water Heater Specification sheets
Add to my manuals
2 Pages
advertisement
EZ98 DV (GQ-C2859WX-FF US)
EZ111 DV (
GQ-C3259WX-FF US
)
Residential Condensing Water Heater
Specification Sheet
•
• Standa r d Input -18,000-180,000 BTUh / 0.5 - 9.8gpm (EZ98)
18,000-199,900 BTUh / 0.5 - 11.1gpm (EZ111)
• C ompa c t Design - ANSI Z21.10.3/CSA 4.3 certified design that can
be wall-mounted indoors or installed outdoors using the optional
Vent Cap
• Wifi Capable
• Heat E x changer - manufactured with austenite SS 316L
• V enting Options - available in Direct Vent model that can use either 2”
or 3” Schedule 40 PVC/CPVC , flexible PP vent, or installed outdoors with
Vent Cap.
• Di r e c t Ele c t r onic Ignition
• Compatible with 1/2” gas pipe - see installation manual
• Multi-S y stem C apabilit y - units can be linked together by using
the optional 2-unit Quick Connect for twice the hot water capacity
• F ully Modulating - BTU input range from 18,000 to 360,000/399,800 BTUh
(with Quick Connect) with stable combustion provided by gas venturi
and pre-mix burner. Each individual unit 10/11:1 Turndown Ratio
•
Uniform
T empe
precisely adjust the output temperature from 100°F to 140°F
• Sa f r atu ety De
Energy Factor (UEF) - 0.96 (NG) / 0.96 (LP) v i r c e Co es nt r ols - includes remote thermostat that can
- Flame Sensor, Overheat Prevention Device,
Lightning Protection Device, Freeze Protection, Condensate Overfill
• 5 Year Limited Parts Warranty & 1 Year Reasonable Labor
• A pp rov als - CSA, UPC , NSF, Low NOx Approved By SCAQMD
This product complies with California AB 1953 Low Lead Law and section 1417(d) of the Safe Drinking Water Act
(Rule 1146.2)
LOW-LEAD
CERTIFIED
R
* Refer to the Noritz Limited Warranty for complete coverage details , at Noritz.com
** This product complies with California AB 1953 Low Lead Law and section 1417(d) of the Safe Drinking Water Act
NORITZ AMERICA CORPORATION
11160 Grace Avenue, Fountain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com
Acc essories
3” Horizontal Hood Termination
(#PVT-HL)
SV Conversion (#SV-CK-2)
Birdscreen (#VT_-PVCS)
Outdoor Vent Cap (#VC-6)
PP Flex Vent Kit (#EZ2FVK-_)
EZTR Conversion Kit (#EZ2-CK)
PVC Concentric Termination
(#PVC-_CT)
Common Vent Non-Return Valve
(#CDVNRVK)
Common Vent PP to PVC Adapter
(#PP4XPVC4-ADAPT)
Isolator Valves (#IK-WV-200)
Wireless Monitor (#NWC-ADAPTER)
Quick Connect Cord (#QC-2)
Neutralizer for 1-unit (#NC-1)
Dimensions
< inch (mm) >
WALL MOUNTING BRACKET
(INCLUDED ACCESSORY)
16" (406mm)
10.2" (260mm)
5.1" (130mm)
0.2" (5mm) 12.8" (325mm)
3.5" (88mm)
1.3" (34mm) 5.1" (130mm)
Ø2.4" (Ø60.8mm)
AIR INLET
18.5" (471mm)
17.8" (451mm)
10.1" (256mm)
Ø2.4" (Ø60.8mm)
FLUE COLLAR HOT WATER OUTLET (3/4”)
17.7" (450mm)
13.4" (340mm)
2.1" (53mm)
WATER DRAIN VALVE
COLD WATER INLET (3/4”) WATER DRAIN VALVE
(WATER FILTER)
GAS INLET (3/4”)
WIRING THOROUGHWAY
(AC120V)
HEIGHT OF EACH FITTING
HOT WATER OUTLET
COLD WATER INLET
CONDENSATE DRAIN
GAS INLET
TOP
TOP
BOTTOM
BOTTOM
1.8" (46mm)
2.3" (59mm)
1.7" (42mm)
2.2" (56mm)
1.1" (28mm)
2.6" (66mm)
3.9" (100mm)
5.5" (140mm)
6.7" (170mm)
0.4" (10mm)
4 x 0.24" x 0.6" (6 x 15mm) OBLONG HOLE
4 x Ø0.5" (Ø13mm)
2 x 0.24" x 0.4" (6 x 10mm) OBLONG HOLE
WATER DRAIN VALVE
2.4" (60mm)
12.7" (322mm)
15.7" (397mm)
CONDENSATE DRAIN (1/2”)
Temperature
Rise (°F)
EZ111
(GPM)
EZ98
(GPM)
30 40 45
11.1 9.8 8.7
9.8 8.6 7.6
50
7.8
6.9
60
6.5
5.7
Flow Rates
70 80
5.6
4.9
4.9
4.4
90
4.4
3.8
100 110 120 130 140
3.9 3.6 3.3 3.0 2.8
3.4 3.1 2.9 2.6 2.4
Pressure Loss
35
30
25
20
15
10
5
0
0.0
1.0
Model Name
Weight
Operating Pressure
Gas Supply Pressure
Water Holding Capacity
Connection
Sizes
Water Inlet
Hot Water Outlet
Gas Inlet
Condensate Drain
Supply
Power
Consumption
Freeze Protection
Temperature Settings
Default Temperature Options
°F Mode
°C Mode
°F Mode
°C Mode
Bypass Flow Control Valve Close Set temperature : 125ºF or higher
(Storage Tank Setting W/ System
Controller : 170-185ºF)
2.0
3.0
Bypass Flow Control Valve Open
Set temperature : 120ºF or less
(Storage Tank Setting W/ System
Controller : 160ºF or less)
4.0
5.0
6.0
7.0
Flow Rate (GPM)
Specifications
8.0
9.0
0
10.0
11.0
12.0
EZ98DV/EZ111DV (GQ-C2859/3259WX-FF US)
81 pounds
15 - 150 psi
NG: 4.0” - 10.5” LP: 8.0” - 14.0”
0.65 Gallon (2.5L)
3/4"
3/4"
3/4"
1/2" Threaded
120VAC (60Hz), less than 4 amperes
NG: 90W LP: 98W Freeze Prevention 178W
Outdoor: -4°F Indoor: -30°F
100-140°F (In 5°F intervals) (9 Options)
37-48°C (In 1°C intervals), 50-60°C (In 5°C intervals) (15 Options)
120, 135, 140°F (Default is 120°F)
50, 55, 60°C (Default is 50°C)
30
20
10
50
40
80
70
60 ut notice.
advertisement