BLUEGRASS LIVING B18TPIR-BB Propane Gas Vent Free Infrared Gas Space Heater With Blower - 18,000 BTU, T-Stat Control Owner's Operation And Installation Manual
Add to my manuals
32 Pages
advertisement
B20TNIR-BB
Model Shown
VENT-FREE GAS
WALL HEATER
OWNER’S OPERATION AND
INSTALLATION MANUAL
INFRARED MODELS
B10TNIR-B, B10TPIR-B
B20TNIR-BB, B18TPIR-BB
B30TNIR-BB, B28TPIR-BB
PFS
®
US
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a quali fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-866-762-4050, 8:00 am - 4:30 pm CST,
Monday through Friday or email [email protected]
TABLE OF CONTENTS
Safety ........................................................ 3
Qualified Installing Agency ........................ 4
Specifications ............................................ 5
Product Features ....................................... 6
Local Codes ............................................... 6
Preparing For Installation .......................... 6
Unpacking .................................................. 7
Water Vapor: A By-Product Of
Unvented Room Heaters ..................... 7
Air For Combustion and Ventilation ........... 7
Installation ................................................. 9
Operation ................................................. 16
Electrical Connection ............................... 18
Electrical Wiring ....................................... 18
Inspecting Burners ................................... 19
Care And Maintenance ............................ 20
Troubleshooting ....................................... 21
Technical Service ..................................... 24
Service Hints ........................................... 24
Parts ........................................................ 25
Replacement Parts .................................. 30
Accessories ............................................. 30
Warranty .................................................. 32
SAVE THIS BOOK
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for ad equate combustion and ventilation air must be provided.
Refer to Air For Combustion and Ventilation section on page 7 of this manual.
WARNING: Improper installation, adjustment, al teration, service or maintenance can cause injury or property damage. Refer to this manual for correct in stallation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
This appliance may be installed in an aftermarket,* per manently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indi cated on the rating plate. This appliance is not convert ible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
2 www.bluegrassliving.com
200458-01A
WARNING: Do not attempt to access or change the setting of the fuel selection means.
Access to and adjustment of the fuel selection means must only be performed by a qualified service person when connecting this appliance to a specified fuel supply at the time of installation.
Change of the selector setting to other than the fuel type speci fied at the time of the installation could damage this appliance and render it inoperable.
The installer shall replace the access cover before completing the installation and operating this appliance.
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, op erate, or service this heater.
Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.
Only a qualified installer, service agent, or local gas supplier may install and service this product.
WARNING: Keep the appli ance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
WARNING: This appliance can be used with propane or natural gas. It is shipped from the factory adjusted for use with propane.
SAFETY
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
DANGER: Carbon monoxide poisoning may lead to death!
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea.
If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.
NATURAL AND PROPANE GAS: Natural and propane gas are odorless. An odormaking agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
WARNING: FIRE, EXPLOSION
AND ASPHYXIATION HAZARD
Improper adjustment, altera tion, service, maintenance, or installation of this heater or its controls can cause death or serious injury.
Read and follow instructions and precautions in User's Informa tion Manual provided with this heater.
WARNING: Do not use any accessories not approved for use with this heater.
WARNING: Carefully super vise young children when they are in the room with the heater.
2000458-01A www.bluegrassliving.com
3
WARNING: Make sure grill guard is in place before running heater.
WARNING: Due to high tem from furniture and draperies.
peratures, the appliance should be located out of traffic and away
WARNING: Heater becomes very hot when running. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns and cloth surfaces to cool before touching.
ing ignition. Heater will remain hot for a time after shutoff. Allow
WARNING: Do not place clothing or other flammable material on or near the appli ance. Never place any objects in the heater.
1. Do not place propane supply tank(s) inside any structure. Propane supply tank(s) must be placed outdoors.
2. Heaters with a maximum input over
6,000 Btu/Hr shall not be installed in a bathroom. Heaters with a maximum input over 10,000 Btu/Hr shall not be installed in a bedroom.
SAFETY
3. This heater needs fresh air ventilation to run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation , pages 7 through 8. If heater keeps shutting off, see
Troubleshooting , page 21.
4. Keep all air openings in front and bottom of heater clear and free of debris. This will ensure enough air for proper combustion.
5. If heater shuts off, do not relight until you have provided fresh, outside air. If heater keeps shutting off, have it serviced.
6. Do not run heater:
• Where flammable liquids or vapors are used or stored.
• Under dusty conditions.
7. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.
8. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
9. Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.
10. Operating heater above elevations of
4,500 feet could cause pilot outage.
11. To prevent performance problems, do not use propane fuel tank of less than 100 lbs. capacity.
QUALIFIED INSTALLING AGENCY
Only a qualified agency should install and replace gas piping, gas utilization equipment or accessories, and repair and equipment servicing. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for:
a) Installing, testing, or replacing gas piping or
b) Connecting, installing, testing, repairing, or servicing equipment; that is experienced in such work; that is familiar with all precautions required; and that has complied with all the requirement of the authority having jurisdiction.
4 www.bluegrassliving.com
200458-01A
SPECIFICATIONS
Ignition
Gas Type
MODEL
BTU (available)
Pressure Regulator Setting
Inlet Gas Pressure*
(inches of water)
B10TNIR-B
Piezo
Natural
B10TPIR-B
Piezo
Propane/LP
10,000
6" W.C.
10,000
10" W.C.
Maximum 10.5" Maximum 14"
Minimum 7" Minimum 11"
Heater Weight
Shipping Weight
14 lbs
16.7 lbs
14 lbs
16.7 lbs
Heater Dimensions (HxWxD) 21.2" × 15.79" × 6.85"
Carton Dimensions (HxWxD) 22.83" × 17.95" × 8.23"
Ignition
Gas Type
MODEL B20TNIR-BB
Piezo
Natural Gas
B18TPIR-BB
Piezo
Propane/LP
BTU (available)
Pressure Regulator Setting
20,000
6" W.C.
18,000
10" W.C.
Maximum 10.5" Maximum 14" Inlet Gas Pressure*
(inches of water)
Heater Weight
Minimum 7"
20.1 lbs
Minimum 11"
20.1 lbs
Shipping Weight 23.4 lbs 23.4 lbs
Heater Dimensions (HxWxD) 24" × 18 1 /
2
" × 8"
Carton Dimensions (HxWxD) 26 1 /
4
" × 20 3 /
4
" × 9 7 /
8
"
Ignition
Gas Type
MODEL
BTU (available)
Pressure Regulator Setting
Inlet Gas Pressure*
(inches of water)
B30TNIR-BB
Piezo
Natural Gas
B28TPIR-BB
Piezo
Propane/LP
30,000
6" W.C.
28,000
10" W.C.
Maximum 10.5" Maximum 14"
Minimum 7" Minimum 11"
Heater Weight
Shipping Weight
25.8 lbs
30 lbs
25.8 lbs
30 lbs
Heater Dimensions (HxWxD) 24 1 /
4
" x 25 1 /
2
" x 8 1 /
2
"
Carton Dimensions (HxWxD) 26 1 /
4
" × 28 1 /
4
" × 9 7 /
8
"
Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).
* For purposes of input adjustment.
2000458-01A www.bluegrassliving.com
5
PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The
ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with a piezo ignitor. this system requires no matches, batteries, or other sources to light heater.
THERMOSTATIC CONTROL
These heaters have a control valve with a thermostat sensing bulb. This results in the greatest heater comfort and may result in lower gas bills.
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54 *.
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.
State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts the gas cock must be a T-handle type. The State of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length.
PREPARING FOR INSTALLATION
Ignitor Button
Control Knob
Before beginning assembly or operation of the product, make sure all parts are present.
Compare parts with package contents list and
Figure 1. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact customer service for replacement parts.
Burner
Grill
Heater Cabinet
6
Front
Panel
Figure 1 - Vent-Free Gas Heater
B20TNIR-BB Shown with Base Feet www.bluegrassliving.com
200458-01A
UNPACKING
1. Remove heater from carton.
2. Remove all protective packaging applied to heater for shipping
3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
WATER VAPOR: A BY-PRODUCT OF
UNVENTED ROOM HEATERS
Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30 mL) of water for every 1,000 BTUs (0.3 KWs) of gas input per hour. Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather.
The following steps will help ensure that water vapor does not become a problem.
1. Be sure the heater is sized properly for the application, including ample combustion air and circulation air.
2. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air.
3. Do not use an unvented room heater as the primary heat source.
AIR FOR COMBUSTION AND VENTILATION
WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in.
During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
2000458-01A www.bluegrassliving.com
WARNING: This heater shall not be installed in a room or space unless the required vol ume of indoor combustion air is provided by the method de scribed in the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, the
International Fuel Gas Code, or applicable local codes.
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code,
ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes.
7
AIR FOR COMBUSTION AND VENTILATION
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options
1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2).
Follow the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Air for Combustion and
Ventilation for required size of ventilation grills or ducts.
12"
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Air for
Combustion and Ventilation for required size of ventilation grills or ducts.
IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.
Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.
Ventilation
Grills into Adjoining
Room,
Option 1
Or
Remove
Door into
Adjoining
Room,
Option 3
Ventilation Grills
Into Adjoining Room,
Option 2 Outlet
Air
Ventilated
Attic
Outlet
Air
To Attic
12"
To
Crawl
Space
Inlet
Air
Inlet Air
Ventilated
Crawl Space
Figure 3 - Ventilation Air from Outdoors
Figure 2 - Ventilation Air from Inside
Building
8 www.bluegrassliving.com
200458-01A
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat.
Use this heater along with your primary heating system. Do not install this heater as your pri mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
WARNING: A qualified ser
CAUTION: When installing heater in a home garage
• heater pilot and burner must be at least 18" above floor
• locate heater where moving vehicle will not hit it
vice person must install heater.
Follow all local codes.
CAUTION: This heater creates warm air currents. These currents move heat to wall sur faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as to bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may cause walls to discolor.
IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form too much moisture.
See Air for Combustion and Ventilation , page 7.
CHECK GAS TYPE
Be sure your gas supply is right for your heater. Otherwise, call dealer where you bought the heater for proper type heater.
CLEARANCES TO
COMBUSTIBLES
Carefully follow the instructions below. This heater is a freestanding unit designed to be mounted on a wall or set on a base.
WARNING: Never install the heater
• in a bathroom. 10,000 BTU/
Hr units can be installed in a bedroom.
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 36" from the front, top, or sides of the heater
• in high traffic areas
• in windy or drafty areas
2000458-01A
WARNING: Maintain the minimum clearances shown in
Figure 4. If you can, provide greater clearances from floor, ceiling, and joining wall.
CEILING
36"
Minimum
8"
Minimum
From
Sides of
Heater
Right
Side
Left
Side
2" Minimum to Top Surface of Carpeting,
Tile or Other Combustible Material
FLOOR
Figure 4 - Mounting Clearances as
Viewed From Front of Heater www.bluegrassliving.com
9
INSTALLATION
LOCATING HEATER
This heater is designed to be mounted on a wall. For convenience and efficiency, install heater:
1. Where there is easy access for operation, inspection, and service.
2. In the coldest part of room.
When installing the appliance directly on carpeting, tile or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extended the full width and depth of the appliance.
INSTALLING THERMOSTAT
SENSING BULB (OPTIONAL)
1. Pull out the sensing bulb from the two clips located in the shipping position. There is no need to take out the two bulb clips.
2. Take out the bulb clip from the hardware package and insert it into the square hole.
Then insert the sensing bulb into the bulb clip (see Figure 5).
Front
Panel
Thermostat
Sensing
Bulb
Bulb Clip
Figure 5 - Moving Thermostat Sensing
Bulb
REMOVING FRONT PANEL
1. Remove 4 screws securing front panel.
2. Carefully slide front panel forward.
Screw
Figure 6 - Removing Front Panel
FASTENING HEATER TO WALL
Mounting Bracket
The mounting bracket is located on back panel of heater. It has been taped there for shipping.
Remove mounting bracket from back panel.
Methods For Attaching Mounting
Bracket To Wall
Use only the last hole on each end of mounting bracket to attach bracket to wall. Attach mounting bracket to a wall only in one of two ways:
1. Attaching to wall stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.
2. Attaching to wall anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).
Decide which method better suits your needs.
Either method will provide a secure hold for the mounting bracket.
Marking Screw Locations
1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.
WARNING: Maintain minimum clearances shown in Figure
4, page 9. If you can, provide greater clearances from floor and joining wall.
10 www.bluegrassliving.com
200458-01A
2. Mark screw locations on wall (see Figure 7). Note: Mark only last hole on each end of mounting bracket. Insert mounting screws through these holes only.
3. Remove tape and mounting bracket from wall.
7 3 /
4
"
12 1 /
4
"
10,000 BTU/Hr Heaters
Non-combustible Flooring or Top of
Combustible Tile Carpeting or Other Material
12 1 /
8
"
12 1 /
4
"
17 3 /
8
"
INSTALLATION
20,000 BTU/Hr Heaters
Non-combustible Flooring or Top of
Combustible Tile Carpeting or Other Material
Attaching to Wall Stud Method
For attaching mounting bracket to wall studs:
1. Drill holes at marked locations using 9/64" drill bit.
2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.
3. Insert mounting screws through bracket and into wall studs.
4. Tighten screws until mounting bracket is firmly fastened to wall studs.
Attaching to Wall Anchor Method
For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls
(concrete or masonry):
1. Drill holes at marked locations using
5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.
2. Fold wall anchor as shown in Figure 8.
3. Insert wall anchor (wings first) into hole.
Tap anchor flush to wall.
4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings (see Figure 9).
IMPORTANT: Do not hammer anchor key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.
5. Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors.
6. Insert mounting screws through bracket and into wall anchors.
7. Tighten screws until mounting bracket is firmly fastened to wall.
30,000 BTU/Hr Heaters
Non-combustible Flooring or Top of
Combustible Tile Carpeting or Other Material
Figure 7 - Mounting Bracket Clearances
Attaching Mounting Bracket To Wall
Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater.
Figure 8 - Folding Anchor
Figure 9 - Popping Open Anchor Wings
For Thin Walls
2000458-01A www.bluegrassliving.com
11
INSTALLATION
Placing Heater On Mounting
Bracket
1. Locate two horizontal slots on back panel of heater (see Figure 10).
2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.
Horizontal Slots
Front View
Front View
Wall
Heater
Stand-
Out
Tab
Spacer
Mounting Bracket
(attached to wall)
Figure 10 - Mounting Heater Onto
Mounting Bracket
Installing Wall Spacers
1. Place heater on wall mounting bracket.
2. Mark screw locations on wall.
3. Remove heater from mounting bracket.
4. If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching To Wall
Anchor Method, page 11. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64" drill bit.
5. Replace heater onto mounting bracket.
6. Place spacers between bottom mounting holes and wall anchor or drilled hole.
7. Hold spacer in place with one hand. With other hand, insert mounting screw though bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole.
8. Tighten both screws until heater is firmly secured to wall. Do not over tighten.
Note: Do not replace front panel at this time.
Replace front panel after making gas connections and checking for leaks.
12
Side View
Figure 11 - Installing Bottom Mounting
Side View
INSTALLING BASE FEET
1. Align screw holes in base feet to the bottom of the heater. Attach using Phillips head screws (provided) (see Figure 12).
2. Position the heater to the desired location.
Secure the base feet to the floor by using two Phillips head screws (provided) (see
Figure 13).
Screw
Hole
Screw
Figure 12 - Attaching Base Feet to Heater
Screw
Figure 13 - Securing Heater to Floor www.bluegrassliving.com
200458-01A
WARNING: A qualified ser vice technician must connect heater to gas supply. Follow all local codes.
WARNING: This appliance requires a 3/8" NPT (National
Pipe Thread) inlet connection to the pressure regulator.
WARNING: For natural gas,
Never connect heater to private
(non-utility) gas wells. This gas is commonly known as wellhead gas.
WARNING: Do not overtighten gas connections.
CAUTION: Use only new, black iron or steel pipe. Inter nally tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of
1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.
CAUTION: For natural gas, check your gas line pressure before connecting heater to gas line. Gas line pressure must be no greater than 10.5" of water. If gas line pressure is higher, heater regulator damage could occur.
INSTALLATION
CONNECTING TO GAS SUPPLY
CAUTION: For propane/LP gas, Never connect heater directly to the gas supply. This heater requires an external regulator
(not supplied). Install the external regulator between the heater and gas supply. Gas supplier provides external regulator for natural gas.
The installer provides the external regulator for propane/LP gas.
CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting into gas piping and/or fittings.
CAUTION: Use pipe joint sealant that is resistant to gas
(Propane/LP or Natural Gas).
Before installing heater, make sure you have the items listed below:
• piping (check local codes)
• sealant (resistant to natural gas and propane/LP gas)
• equipment shutoff valve*
• test gauge connection*
• sediment trap
• tee joint
• pipe wrench
• flexible gas hose (check local codes)
* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design certified equipment shutoff valve from your dealer.
Typical Inlet Pipe Diameters
Use 3/8" black iron pipe or greater. Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure
12, page 14).
IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.
2000458-01A www.bluegrassliving.com
13
INSTALLATION
Apply pipe joint sealant lightly to male threads.
This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water.
If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 15. Pointing the vent down protects it from freezing rain or sleet.
Install sediment trap in supply line as shown in Figure 14. Place sediment trap where it is within reach for cleaning. Place sediment trap where trapped matter is not likely to freeze.
A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
Ground
Joint Union
Test Gauge
Connection*
Tee Joint
Reducer
Bushing to
1/8" NPT
1/8" NPT
Plug Tap
3/8" NPT
Pipe Nipple
Equipment
Shutoff Valve
Natural Gas
From Gas Meter
(7" W.C.** to 10.5"
W.C. Pressure)
3" Minimum
Propane/LP
Supply Tank
Propane/LP
From External
Regulator (11"
W.C.** to 14" W.C.
Pressure)
External
Regulator with
Vent Pointing
Down
Sediment
Trap
Tee Joint
Pipe Nipple
Gap
Figure 14 - Gas Connection
* Purchase the optional CSA design-certified equipment shutoff valve from your dealer.
Figure 15 - External Regulator with Vent Pointing Down
14 www.bluegrassliving.com
200458-01A
INSTALLATION
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.
WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. If bubbles form, there is a leak. Correct all leaks at once.
1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator.
2. Cap off open end of gas pipe where equipment shutoff valve was connected.
3. Pressurize supply piping system by either ply valve.
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. If bubbles form, there may be a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.
using compressed air or opening gas supure 16).
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Fig-
2. Pressurize supply piping system by either using compressed air or opening gas supply valve.
Gas Valve
Propane/LP
Supply Tank
3. Check all joints from gas supply (see Figure 17 or 18) to equipment shutoff valve.
Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Equipment
Shutoff Valve
Equipment
Shutoff Valve
Open
Closed
Figure 16 - Equipment Shutoff Valve
Figure 17 - Checking Gas Joints for
Propane/LP Gas
Gas Valve
Gas Meter
(Regulator supplied by gas company)
External
Regulator
Supplied by Gas
Supplier
2000458-01A
Equipment Shutoff Valve
Figure 18 - Checking Gas Joints for
Natural Gas www.bluegrassliving.com
15
INSTALLATION
PRESSURE TESTING HEATER GAS CONNECTIONS
1. Open equipment shutoff valve (see Figure 16, page 15).
2. Open gas supply tank valve.
3. Make sure control knob of heater is in the
OFF position.
4. Check all joints from equipment shutoff valve to control valve (see Figure 17 or
18, page 15). Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Lighting Instructions on page 16). Check all other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to
Appliance , page 17).
OPERATION
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result caus ing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools.
If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise to the
OFF position.
4. Wait five (5) minutes to clear out any air.
Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step.
5. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds.
Note: The first time that the heater is oper ated after connecting the gas supply,the control knob should be pressed for about thirty (30) seconds. This will allow air to bleed from the gas system. If pilot does not stay lit, refer to Troubleshooting, pages
21 though 23. Also contact a qualified service technician or gas supplier for repairs. Until repairs are made, light pilot with match.
• If control knob does not pop up when released, contact a qualified service technician or gas supplier for repairs.
16 www.bluegrassliving.com
200458-01A
OPERATION
6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the grill. If needed, keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, pages 21 though 23.
Also contact a qualified service technician or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. If control knob does not pop up when released, contact a qualified service technician or gas supplier for repairs.
Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.
8. Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.
IGNITOR
Control
Knob
PILOT
OFF
HI
LO
Figure 19 - Control Knob in the OFF
Position
Thermocouple
Ignitor Electrode
Pilot Burner
Figure 20 - Pilot
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
OFF
Figure 21 - Burner Patterns
THERMOSTAT CONTROL OPERATION
The thermostatic control used on these models differ from standard thermostats. Standard thermostats simply turn the burner on and off.
The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any comfort level between HI and LO.
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise
OFF position.
to the
Shutting Off Burner Only
(pilot stays lit)
Turn control knob clockwise
PILOT position.
to the
MANUAL LIGHTING PROCEDURE
1. Remove lower front panel.
2. Follow steps 1 through 5 under Lighting
Instructions , page 16.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Follow step 8 under
Lighting Instructions , page 17.
5. Replace lower front panel.
2000458-01A www.bluegrassliving.com
17
ELECTRICAL CONNECTION
FOR BLOWER KIT
A
Do not use this heater if any part of it has been under water.
Immediately call a qualified ser vice technician to inspect the heater and replace any part of the electrical system which has been under water.
GROUNDING INSTRUCTIONS
This heater is for use on 120 volts. The cord has a plug as shown at A in Figure 22. An adapter as shown at C is available for connecting three-blade grounding-type plugs to two-slot receptacles. The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.
Grounding Pin
B
Cover of
Grounded
Outlet Box
C
Metal Screw
Adapter
(Sold
Separately)
Grounding Means
Figure 22 - Grounded Electrical Outlet
FAN OPERATION
To operate the manual unit, turn ON/OFF switch to the ON position. To operate the
Automatic unit, turn AUTO/O/MAN switch to the desired position. MAN position will remain constantly on. AUTO position will be controlled by the sensor on the fan blower unit. The sensor will be activated when the temperature of the sensor head reaches the set point of the switch after the heater is started. To stop the operation, turn the switch to the O position.
ELECTRICAL WIRING
Any electrical re-wiring of this appliance must be done by a qualified electrician. This wiring must be done in accordance with local codes and/or in Canada with the current CSA C22.1
Canadian Electrical Code , and for US installations, the National Electrical Code ANSI/
NFPA NO 70 .
WARNING: If repairing or replacing any electrical compo ing locations must be followed.
nent or wiring, the original wire routing, color coding and secur -
WARNING: Never attempt to service heater while it is plugged in, operating, or hot. Burns and electrical shock could result.
Only a qualified service person should service or repair heater.
Verify proper operation after servicing. If any of the original wire as supplied with the appliance must be replaced, it must be replaced with a wire of at least a 105º C temperature rating.
Thermostat Switch
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and danger ous operation.
Black
Green
White
Switch
AUTO
O
MAN
Motor
18 www.bluegrassliving.com
200458-01A
INSPECTING BURNERS
IMPORTANT: Owner’s should check pilot flame pattern and burner flame pattern often.
Incorrect flame patterns indicate the need for cleaning (see Care and Maintenance, page 20) or service.
WARNING: Only a qualified service person should service and repair heater. This includes maintenance requiring replacement or alteration of components.
PILOT FLAME PATTERN
Figure 23 shows a correct pilot flame pattern.
Figure 24 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool, which shuts the heater off.
If pilot flame pattern is incorrect, as shown in Figure 24
• turn heater off (see To Turn Off Gas to Ap pliance , page 17)
• see Troubleshooting pages 21 through 23.
Notice: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.
Figure 23 - Correct Pilot Flame Pattern
WARNING: If yellow tipping occurs, your heater could pro duce increased levels of carbon monoxide. If the burner flame pattern shows yellow tipping, follow instructions below.
Figure 24 - Incorrect Pilot Flame Pattern
BURNER FLAME PATTERN
Figure 25 shows a correct burner flame pattern. Figure 26 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the heat shield height.
If burner flame pattern is incorrect, as shown in Figure 25
• turn heater off (see To Turn Off Gas to Ap pliance , page 17)
• see Troubleshooting pages 21 through 23.
Figure 25 - Correct Burner Flame Pattern
2000458-01A
Figure 26 - Incorrect Burner Flame
Pattern www.bluegrassliving.com
19
CARE AND MAINTENANCE
WARNING: Turn off heater and let cool before servicing.
CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service techni cian. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.
WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.
MAIN BURNER
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off the heater and let it cool, and remove blockage or replace burner. Blocked burner flame holes will create soot.
BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE
We recommend that you clean the unit every 2,500 hours of operation or every three months. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSl. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don’t follow
ODS/PILOT directions on the can, you could damage the pilot assembly.
1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.
2. Remove four screws securing front panel.
3. Pull front panel forward.
4. Inspect burner and pilot for dust and dirt.
5. Blow air through the ports/slots and holes in the burner.
6. Replace front panel using screws removed.
Use a vacuum cleaner, pressurized air, or a small, soft bristled brush to clean.
A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about 2" from where the pilot flame comes out of the pilot assembly
(see Figure 27). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Thermocouple Ignitor
Electrode
Pilot
Assembly
Pilot Air Inlet Hole
Figure 26 - Pilot Inlet Air Hole
CABINET
Air Passageways
Use a vacuum cleaner or pressurized air to clean.
Exterior
• Use a soft cloth dampened with a mild soap and water mixture.
• Wipe the cabinet to remove dust.
20 www.bluegrassliving.com
200458-01A
TROUBLESHOOTING
WARNING: If you smell gas:
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Fol low the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
WARNING: Only a qualified service technician should service and repair heater. Make sure that power is turned off before proceeding.
Turn off and let cool before servicing.
CAUTION: Never use a wire, needle, or similar object to clean
ODS/pilot. This can damage ODS/ pilot unit.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
Note: All troubleshooting items are listed in order of operation.
Problem
When ignitor button is pressed in, there is no spark at ODS/pilot.
Possible Cause
1. Ignitor electrode is positioned wrong. Ignitor electrode is broken.
2. Ignitor electrode is not connected to ignitor cable.
3. Ignitor cable is pinched or wet.
Corrective Action
1. Replace pilot assembly.
2. Replace ignitor cable.
When ignitor button is pressed in there is a spark at ODS/pilot but no ignition.
4 Broken ignitor cable.
5. Bad piezo ignitor.
1. Gas supply is turned off or equipment shutoff valve is closed.
2. Control knob not fully pressed in while pressing ignitor button.
3. Air in gas lines when installed.
3. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry.
4. Replace ignitor cable.
5. Replace piezo ignitor.
1. Turn on gas supply or open equipment shutoff valve.
2. Fully press in control knob while pressing ignitor button.
4. ODS / pilot is clogged.
5. Incorrect inlet gas pressure or inlet regulator is damaged.
6. Control knob not in PILOT position.
7. Depleted gas supply (propane).
3. Continue holding down control knob. Repeat igniting operation until air is removed.
4. Clean ODS/pilot (see Care and Maintenance , page 20) or replace ODS/pilot assembly.
5. Check inlet gas pressure or replace inlet gas regulator.
6. Turn control knob to PILOT position.
7. Contact local propane/LP gas company.
2000458-01A www.bluegrassliving.com
21
TROUBLESHOOTING bustion.
Problem
ODS/pilot lights but flame goes out when control knob is released.
Burner(s) does not light after ODS/pilot is lit.
Delayed ignition of burner(s).
Burner backfiring during combustion
High yellow flame during burner combustion
Gas odor during com-
Slight smoke or odor during initial operation.
Possible Cause
1. Control knob is not fully pressed in.
2. Control knob is not pressed in long enough.
3. Equipment shutoff valve is not fully open.
4. Thermocouple connection is loose at control valve.
5. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
6. Thermocouple damaged.
7. Control valve damaged.
1. Burner orifice is clogged.
2. Inlet gas pressure is too low.
1. Manifold pressure is too low.
2. Burner orifice is clogged.
1. Burner orifice is clogged or damaged.
2. Burner is damaged.
3. Gas regulator is damaged.
1. Not enough air.
2. Gas regulator is defective.
3. Inlet gas pressure is too low.
1. Foreign matter between control valve and burner.
2. Gas leak. (See Warning
Statement at top of page 21).
1. Residues from manufacturing process.
Corrective Action
1. Press in control knob fully.
2. After ODS/pilot lights, keep control knob pressed in 30 seconds.
3. Fully open equipment shutoff valve.
4. Hand tighten until snug, and then tighten 1/4 turn more.
5. A) Contact local natural or propane/LP gas company
B) Clean ODS/pilot (see
Care and Maintenance , page
20) or replace ODS/pilot assembly
6. Replace thermocouple.
7. Replace control valve.
1. Clean burner orifice (see
Care and Maintenance , page
20).
2. Contact local gas supplier.
1. Contact local gas supplier.
2. Clean burner (see Care and
Maintenance , page 20).
1.
Clean burner orifice (see
Care and Maintenance , page 20).
2. Contact customer service.
3. Replace gas regulator.
1. Check burner for dirt and debris.
If found, clean burner (see Care and Maintenance , page 20).
2. Replace gas regulator.
3. Contact local gas supplier.
1. Take apart gas tubing and remove foreign matter.
2. Locate and correct all leaks
(see Checking Gas Connections , page 15).
1. Problem will stop after a few hours of operation.
22 www.bluegrassliving.com
200458-01A
TROUBLESHOOTING
Problem
Heater produces a whistling noise when burner is lit.
Possible Cause
1. Turning control knob to the high position when burner is cold.
2. Air in gas line.
Heater produces a clicking/ticking noise just after burner is lit or shut off.
3. Air passageways on heater are blocked.
4. Dirty or partially clogged burner orifice.
1. Metal is expanding while heating or contracting while cooling.
Corrective Action
1. Turn control knob to the low position and let warm up for a minute.
2. Operate burner until air is removed from line. Have gas line checked by local gas supplier.
3 Observe minimum installation clearances (Figure 4, page 9).
4 Clean burner (see Care and
Maintenance , page 20).
1. This is common with most heaters. If noise is excessive, contact qualified service technician.
1. Turn heater off when using furniture polish, wax, carpet cleaner or similar products.
White powder residue forming within burner box or on adjacent walls or furniture.
Heater produces unwanted odors.
1. When heated, the vapors from furniture polish, wax, carpet cleaners, etc., turn into white powder residue.
1. Heater is burning vapors from paint, hair spray, glues, etc. See
IMPORTANT statement, page 20.
2. Gas leak. See Warning Statement at the top of page 21.
Heater shuts off in use
(ODS operates).
Gas odor exists even when control knob is in
OFF position.
Moisture/condensation noticed on windows.
3 Low fuel supply (propane/LP gas only).
1. Not enough fresh air is available.
2. Low line pressure.
3. ODS/pilot is partially clogged.
1. Gas leak. See Warning
Statement at top of page 21.
2. Control valve is defective.
1. Not enough combustion/ ventilation air.
1. Ventilate room. Stop using odor causing products while heater is running.
2. Locate and correct all leaks
(see Checking Gas Connections , page 15).
3. Refill supply tank (Propane/
LP models).
1. Open window and/or door for ventilation.
2. Contact local gas supplier.
3. Clean ODS/pilot (see Care and Maintenance , page 20).
1. Locate and correct all leaks
(see Checking Gas Connections , page 15).
2. Replace control valve.
1. Refer to Air for Combustion and Ventilation requirements, page 7.
2000458-01A www.bluegrassliving.com
23
TECHNICAL SERVICE
You may have further questions about installation, operation, or troubleshooting. If so, contact
Bluegrass Living, Inc. at 1-866-762-4050.
When calling, please have your model and serial numbers of your heater ready.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply might be low (propane/LP units only)
You may feel your gas pressure is too low. If so, contact your local gas supplier.
24 www.bluegrassliving.com
200458-01A
14
17
12
PARTS
MODELS B10TNIR-B, B10TPIR-B
11
10
2
3
15
1
4
16
13 5
6
8
9
7
18
2000458-01A www.bluegrassliving.com
25
PARTS
MODELS B10TNIR-B, B10TPIR-B
This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 30 of this manual.
9
10
7
8
ITEM B10TNIR-B
1 **
2 161132-01
3
4
5
6
ML083-03
161130-01
**
162322-05
RV81FIL-6
**
**
**
B10TPIR-B
**
161132-01
ML083-03
161130-01
**
162332-01
RV81FIL-10
**
**
**
DESCRIPTION
Back Body Panel
Mounting Bracket
Piezo Ignitor
Thermostat Control Valve
Burner Assembly
ODS Pilot
Regulator
Orifice Retainer
Injector
Reflector Assembly
11 **
12 162962-01
**
162962-01
Top Reflector
Front Panel Assembly
13 161528-01HT 161528-01HT Screen
14 162960-01 162960-01 Lower Mesh Grill
15
16
**
**
**
**
Bezel, Control
Cabinet Bracket
17 161229-01HT 161229-01HT Upper Mesh Grill
18 BF0910B-BK BF0910B-BK Base Feet
161607-01
PART AVAILABLE - NOT SHOWN
161607-01 Hardware Package
1
1
1
1
1
1
1
1
1
1
1
QTY
1
1
1
1
1
1
1
** Not a field replaceable part.
26 www.bluegrassliving.com
200458-01A
PARTS
MODELS B20TNIR-BB, B18TPIR-BB, B30TNIR-BB, B28TPIR-BB
30,000 BTU/Hr
Heater Shown
13
11
18
19
3
16
2
14
15
5
8
10
6
4
17
9
7
20
12
1
2000458-01A www.bluegrassliving.com
27
PARTS
MODELS B20TNIR-BB, B18TPIR-BB
This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 30 of this manual.
ITEM B20TNIR-BB B18TPIR-BB
1 ** **
2
3
4
161132-01
161133-01
161130-01
5 **
6 162332-04
7 RV81FIL-6
161132-01
161133-01
161130-01
**
162332-02
DESCRIPTION
Back Body Panel
Mounting Bracket
Piezo Ignitor
QTY
1
1
1
Thermostat Control Valve 1
Burner Assembly
ODS Pilot
RV81FIL-10 Regulator
8
9
10
11
----------
**
----------
**
----------
**
----------
**
Orifice Retainer
Injector
Injector
Reflector Assembly
-
1
-
2
1
1
1
12 **
13 162962-02
**
162962-02
Cabinet Bracket
Front Panel Assembly
14 161142-01HT 161142-01HT Screen
15
16
17
162960-02
**
**
18 161226-01HT 161226-01HT Upper Mesh Grill
161607-01
162960-02
**
**
BF09B-BK Base Feet
PART AVAILABLE - NOT SHOWN
161607-01
Lower Mesh Grill
Bezel, Control
Orifice Retainer
19 MGB100-BK MGB100-BK Blower Assembly
20 BF09B-BK
Hardware Package
1
1
1
1
1
1
1
1
1
1
** Not a field replaceable part.
28 www.bluegrassliving.com
200458-01A
PARTS
MODELS B30TNIR-BB, B28TPIR-BB
This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 30 of this manual.
10
11
8
9
ITEM B30TNIR-BB B28TPIR-BB
1 ** **
2
3
4
161562-01
161133-01
161130-01
5 **
6 162332-04
7 RV81FIL-6
161562-01
161133-01
161130-01
**
162332-02
DESCRIPTION
Back Body Panel
Mounting Bracket
Piezo Ignitor
QTY
1
1
1
Thermostat Control Valve 1
Burner Assembly
ODS Pilot
RV81FIL-10 Regulator
**
**
**
**
**
**
**
**
Orifice Retainer
Injector
Injector
Reflector Assembly
1
1
1
2
1
1
1
12 **
13 162962-03
**
162962-03
Cabinet Bracket
Front Panel Assembly
14 161565-01HT 161565-01HT Screen
15
16
17
162960-03
**
**
18 161228-01HT 161228-01HT Upper Mesh Grill
161607-01
162960-03
**
**
BF09B-BK Base Feet
PART AVAILABLE - NOT SHOWN
161607-01
Lower Mesh Grill
Bezel, Control
Orifice Retainer
19 MGB100-BK MGB100-BK Blower Assembly
20 BF09B-BK
Hardware Package
1
1
1
1
1
1
1
1
1
1
** Not a field replaceable part.
2000458-01A www.bluegrassliving.com
29
REPLACEMENT PARTS
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
• Your name
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement parts, call Customer Service toll free at
1-866-762-4050 for referral information.
When calling Customer Service or your dealer, have ready:
• Model and serial number of your heater
• How heater was malfunctioning
• Type of gas used (Propane/LP or Natural gas/NG)
• Purchase date
Usually, we will ask you to return the defective part to the factory
• Your address
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement part(s) call Customer Service toll free at
1-866-762-4050 for referral information.
When calling Customer Service have ready:
• Model number of your heater
• The replacement part number
ACCESSORIES
To purchase these heating accessories please visit our website www.bluegrassliving.com
or give us a call at 1-866-762-4050.
EQUIPMENT SHUTOFF VALVE
For all models. Equipment shutoff valve with 1/8" NPT tap.
INSTALLATION KITS
Existing Gas Line
22" Flexible
Connector
Brass Shutoff Valve
1/2" Male Flare x 1/2" Male Pipe
1/2" Male Flare x 3/8" Male Pipe
1/2" Male Flare x 3/8" Female Pipe
30 www.bluegrassliving.com
200458-01A
NOTES
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
2000458-01A www.bluegrassliving.com
31
WARRANTY
KEEP THIS WARRANTY
Model _______________________________
Serial No. ____________________________
Date Purchased _______________________
Keep receipt for warranty verification.
REGISTER YOUR PRODUCT AT WWW.BLUEGRASSLIVING.COM
BLUEGRASS LIVING LIMITED WARRANTIES
New Products
Standard Warranty: Bluegrass Living warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of one (1) year from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with
Bluegrass Living’s warnings and instructions.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.
Factory Reconditioned Products
Limited Warranty: Bluegrass Living warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for a period 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with Bluegrass Living’s warnings and instructions. No return will be authorized. Parts will be provided to repair the product.
Terms Common to All Warranties
The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty, the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product.
This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allowance for labor when provided by a Bluegrass Living Authorized Service Center or a provider approved by Bluegrass Living. Warranty parts must be obtained through authorized dealers of this product and/or Bluegrass Living who will provide original factory replacement parts. Failure to use original factory replacement parts will void this warranty.
Traveling, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering or alteration(s).
This is Bluegrass Living’s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to one
(1) year on new products and 30 days on factory reconditioned products from the date of first purchase.
Bluegrass Living makes no other warranties regarding this product.
Bluegrass Living’s liability is limited to the purchase price of the product and Bluegrass Living shall not be liable for any other damages whatsoever under any circumstances including direct, indirect, incidental, or consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Bluegrass Living, Inc.
2800 Griffin Drive
Bowling Green, KY 42101
1-866-762-4050
200458-01
Rev. A
08/19
32 www.bluegrassliving.com