LG Electronics LP123HD3B 12,000/12,200 BTU Packaged Terminal Air Conditioner Product data


Add to my manuals
71 Pages

advertisement

LG Electronics LP123HD3B 12,000/12,200 BTU Packaged Terminal Air Conditioner Product data | Manualzz

PTAC Type

(60Hz/R410A)

6RWU0-03A

PTAC

Introduction

Part 1 General information

1. Model line up ....................................................................................12

2. Nomenclature ...................................................................................13

3. Appearance.......................................................................................14

4. List of functions ...............................................................................15

5. Features ............................................................................................16

Part 2 Product data

1 YA chassis ........................................................................................22

1.1 Features........................................................................................................22

1.2 List of functions.............................................................................................23

1.3 Specifications................................................................................................24

1.4 Dimensions ...................................................................................................30

1.5 Piping diagrams ............................................................................................31

1.6 Wiring diagrams............................................................................................33

1.7 Capacity tables .............................................................................................35

1.8 Electrical characteristics ...............................................................................43

1.9 Operation range............................................................................................44

2 Control Devices...............................................................................45

2.1 Electronic Controls........................................................................................45

Part 3 Design and installation

1 General installation procedure........................................................51

2 Installation of unit.............................................................................52

2.1 Safety precautions .........................................................................................52

2.2 Points of explanation about operations .........................................................55

2.3 Selecting installation site for the unit .............................................................55

2.4 Installation of unit...........................................................................................56

2.5 Wall sleeve installation ..................................................................................58

Part 4 Accessories

1 Controller accessories ....................................................................65

1.1 Hard Wire kit .................................................................................................65

1.2 Wired Wall Thermostat Connection Kit .........................................................67

2 Mechanical accessories ..................................................................68

2.1 Stamped Aluminum Grille - Single Pack .......................................................68

2.2 Remote Escutcheon Kit - 10 Pack ................................................................69

2.3 Replacement Filter - 10 Pack........................................................................70

2.4 Vent Filter .....................................................................................................70

Test condition of International Standards

Test condition of International Standards

6RWU0-03A

KSC ISO ARI AHAM AS SSA

CLASSIFICATION

9306 5151 210/240 1861.1 385

Indoor

DB°C(°F) 27.0 27.0 26.7(80) 26.7(80) 27.0 29.0

Cooling WB°C(°F) 19.5 19.0 19.4(67) 19.4(67) 19.0 19.0

Capacity

Outdoor

DB°C(°F) 35.0 35.0 35.0(95) 35.0(95) 35.0 46.0

WB°C(°F) 24.0 24.0 23.9(75) 23.9(75) 24.0 24.0

Indoor

DB°C(°F) 20.0 20.0 21.1(70) 21.1(70) 21.0 21.0

Heating WB°C(°F) 15.0 15.0 15.6(60) 15.6(60) 15.0 15.5

Capacity

Outdoor

DB°C(°F) 7.0 7.0 8.3(47) 8.3(47) 7.0 7.0

WB°C(°F) 6.0 6.0 6.1(43) 6.1(43) 6.0 6.0

Maximum

Indoor

DB°C(°F) 32.0 32.0 26.7(80) 32.2(90) 32.0 29.0

WB°C(°F) 23.0 23.0 19.4(67) 22.8(73) 23.0 19.0

Cooling

Operating

Outdoor

DB°C(°F) 43.0 43.0 46.1(115) 43.3(110) 43.0 54.0

WB°C(°F) 26.0 26.0 23.9(75) 25.6(78) 26.0 24.0

Maximum

Indoor

DB°C(°F) 27.0 27.0 26.7(80) 26.7(80) - -

WB°C(°F) 19.0 19.0 19.4(67) 22.8(73) - -

Heating

Operating

Outdoor

DB°C(°F) 21.0 24.0 23.9(75) 23.9(75) - -

WB°C(°F) 15.0 18.0 18.3(65) 18.3(65) - -

Enclosure

Indoor

DB°C(°F) 27.0 27.0 26.7(80) 26.7(80) 27.0 27.0

Sweat / WB°C(°F) 24.0 24.0 23.9(75) 23.9(75) 24.0 24.0

Condensate

Outdoor

DB°C(°F) 27.0 27.0 26.7(80) 26.7(80) 27.0 27.0

Disposal WB°C(°F) 24.0 24.0 23.9(75) 23.9(75) 24.0 24.0

Freeze-up/ Indoor

DB°C(°F) 21.0 21.0 19.4(67) 21.1(70) 21.0 21.0

Low

WB°C(°F) 15.0 15.0 13.9(57) 15.6(60) 16.0 16.0

DB°C(°F) 21.0 21.0 19.4(67) 21.1(70) 21.0 21.0

Temperature Outdoor

WB°C(°F) 15.0 15.0 13.9(57) 15.6(60) 16.0 16.0

KS : Korea Standard AS : Australia Standard

ISO : International Standard Organization SSA : Saudi Arabian Standard

ARI : Airconditioning and Refrigeration Institute

AHAM : Association of Home Appliance Manufacturers

In the table above, temperatures are expressed in Fahrenheit(°F) within parentheses only for ARI and AHAM standards.

6RWU0-03A

Introduction

Introduction

Preface

Packaged Terminal Air-Conditioners(PTAC) of LG is the best choice a customer can avail when it comes to a quiet environment. Ultra quiet operation is the hallmark of these Air-Conditioners of LG. These range of units are suitable for Hotels and

Healthcare applications. These units have extremely low noise levels and outstanding sound prevention ratings. Moreover, these units have higher Energy ratings which results in excellent energy savings.

These units are also provided with unique features to provide better usability and easy installation for the user.

The capacity of these PTAC models ranges from 7,000 Btu/h to 15,000 Btu/h.

Some of the important features of this units are as follows:-

Long term money saving: By providing features such as Gold Fin etc... to maintain the same performance throughout the life of the Air-Conditioner.

Comfort : With features such as Wall Thermostat temperature control, Auto Restart, etc…, which gives ultimate comfort to our customer.

These units are equipped with many standard and optional features for our customers and for details please refer to the detailed specification followed after this description.

LG Electronics Inc.

Air Conditioning & Energy Solution Company

Introduction

Publication History

Pub. No.

6RWU0 - 01A

6RWU0 - 01B

6RWU0 – 01C

6RWU0 – 01D

6RWU0 – 02A

6RWU0 – 02B

6RWU0 – 02C

6RWU0-03A

Frequency Category

60Hz RAC

60Hz

60Hz

RAC

RAC

60Hz

60Hz

RAC

RAC

60Hz

60Hz

60Hz

RAC

RAC

RAC

Product name

PTAC

PTAC

PTAC

PTAC

PTAC

PTAC

PTAC

PTAC

Refrigerant

R410A

R410A

R410A

R410A

R410A

R410A

R410A

R410A

6RWU0-03A

Notes

New Edition of PDB

Spec sheet update

Spec sheet update

Add Operation range

2011 New line-up update

Modified Capacity Table

Spec Sheet Update

2013 Model Line Up

Published in

Apr.2010

June.2010

August. 2010

Dec. 2010

Apr. 2011

Apr. 2012

Apr. 2012

Mar, 2013

6RWU0-03A

Step by step air conditioner selection process (reference)

(1) Calculate or obtain the maximum heat load for the area to be air conditioned.

Introduction

(2)

Specifications

Model features and functions

Air-flow and temperature distribution

(3)

Selection of the control system

Remote Wall Thermostat Control

Front Desk Control

CAUTION

1. Air conditioners should not be installed in areas where corrosive gases such as acid gas or

alkaline gas is present.

Note :

Here in this PDB, the temperature units are generally expressed in Fahrenheit (°F) but for specific regions please conform to local standards whenever necessary.

6RWU0-03A

Part 1 General information

1. Model line up .......................................................................................12

2. Nomenclature ......................................................................................13

3. Appearance ..........................................................................................14

4. List of functions ..................................................................................15

5. Features ...............................................................................................16

Model line up

1. Model line up

Chassis

YA

6RWU0-03A

Model names

Capacity, kW ( kBtu/h)

2.05(7) 2.64(9) 3.52(12) 4.4(15)

UYC073ALE21(LP073CD2B)

UYH073ALE21(LP073HD2B)

UYC093ALE31(LP093CD3B)

UYH093ALE31(LP093HD3B)

UYC09EALE31(LP096CD3B)

UYH09EALE31(LP096HD3B)

UYC123ALE31(LP123CD3B)

UYH123ALE31(LP123HD3B)

UYC12EALE31(LP126CD3B)

UYH12EALE31(LP126HD3B)

UYC153ALE31(LP153CD3B)

UYH153ALE31(LP153HD3B)

6RWU0-03A

2. Nomenclature

Global standard

[New version]

U Y C 0 7 3 A L E 2 1

Nomenclature

Model Development serial number.

Heater Capacity:

0kW: No Heater 2kW: 2.0 ~ 2.9 4kW : 4.0 ~ 4.9

1kW: 1.0 ~ 1.9 3kW: 3.0 ~ 3.9 5kW : 5.0 ~ 5.9

Function.

A: Cooling Standard

B: Cooling + Corrosion Protection

C: Cooling + Condensate Pump

E: Electronic

H: Heat Pump Standard

J: Heat Pump + Corrosion Protection

K: Heat Pump + Condensate Pump

Look.

L: LG

Chassis : A – YA chassis.

Power Rating:

1: 115V, 60Hz

2: 220V, 60Hz

3: 208-230V, 60Hz

5: 200-220V, 50Hz

Cooling/Heating Capacity.

Ex) 07 -> 7,000 Btu/h Class

6: 220-240V, 50Hz E: 265V, 60Hz

7: 110V, 50-60Hz

8: 380-415V, 50Hz

9: 380-415V, 60Hz

Model Type:

C: Cooling + Electric Heater or Cooling only.

H: Heat pump + Electric Heater or Heat Pump only.

W: Window Air Conditioner

Y: Packaged Terminal Air Conditioner

X: Through the Wall Air Conditioner

E: Casement Air Conditioner

U: SPVU Air Conditioner

L: Condole Air Conditioner

Q: Low Profile Air Conditioner

Production Center, Refrigerant

L: Changwon R22 N: India

A: Changwon R410A Z: Brazil

C: Changwon R407C D: Indonesia

T: China M: Mexico

K: Turkey R22 V: Vietnam

E: Turkey R410A S: Outsourcing

H: Thailand U: China R410A

Appearance

3. Appearance

Chassis Unit

YA

Models

UYC073ALE21(LP073CD2B)

UYH073ALE21(LP073HD2B)

UYC093ALE31(LP093CD3B)

UYH093ALE31(LP093HD3B)

UYC09EALE31(LP096CD3B)

UYH09EALE31(LP096HD3B)

UYC123ALE31(LP123CD3B)

UYH123ALE31(LP123HD3B)

UYC12EALE31(LP126CD3B)

UYH12EALE31(LP126HD3B)

UYC153ALE31(LP153CD3B)

UYH153ALE31(LP153HD3B)

6RWU0-03A

6RWU0-03A

4. List of functions

List of functions

Category Function

PTAC Type

Cooling only Models

PTAC Type

Heat Pump Models

Air discharge type Top discharge Top discharge

Airflow direction control (up & down) Manual Manual

Airflow direction control (left & right) - -

Air flow

Auto swing - -

Airflow steps (fan/cool/heat) 2/2/2 2/2/2

Airflow Direction 2 way 2 way

Deodorizing filter - -

Air filter (washable / anti-fungus) O O

Auto restart operation O O

Micom control O O

Forced operation - -

Sleep mode - -

Timer O O

Wired remote controller O O control

Wireless LCD remote control O O

Energy save mode O O

Thermistor O O

O : applied

- : not applied

Features

5. Features

6RWU0-03A

The following features can be found in PTAC (Packaged Terminal Air-Conditioners) :n

2 -Way Air Flow Direction n Washable Filters n Low Noise at High Air Volume n

High Efficiency Compressor n Energy Saver Mode n

Timer n

Electric Heater n Deice Control n

Air Ventilation n Energy saving Anti-corrosion treated Fins n Infinite Impulse Response(IIR) n

Compressor Restart Delay n Fan only Setting n

Indoor Fan Speed Setting n n n

Two Fan Motors n LED Diagnostics and Self Diagnostics n 2 Position Discharge Grille n

Indoor Room Freeze Protection n Door Switch/Occupancy Sensor n

Compressor Overload Protection n

Outdoor Air Temperature Switchover n Temperature Limits n

Condensate Drain Valve n Quick Heater Recovery n Reverse Cycle Defrosting (PTHPʼs only) n

High Temperature Heat Pump operation Protection

Remote Thermostat Control

Zone Sensor

2 -Way Air Flow Direction

40 15

Air Flow can be adjusted by changing the direction of the air conditionerʼs louvers to attain the desired level of comfort and convenience. This can also increase the cooling efficiency of the air conditioner.

In order to attain maximum cooling efficiency, adjust the louvers so that they face upwards.

6RWU0-03A

Washable Filters

Features

The Unit uses two filters on the indoor side which can be slid easily. These filters can be taken out without removing the

Front Grille and then cleaned by washing or brushing.

The filters should be checked and cleaned every two(2) weeks or as necessary to maintain the optimal performance of the air conditioner depending upon the region and purpose of application.

Low Noise at High Air Volume

New Blowers and Fans which are bigger and stronger than earlier ones operate at low rpmʼs and have higher efficiency.

High Efficiency Compressor

LG Rotary compressors have low noise, low vibration and higher efficiency and reliability.

Energy save mode

This feature employs a programmable logic which enables the unit to minimize power consumption. When the switch is activated in the “on” position, the Indoor fan turns off as soon as the compressor stops running. And in the “off” mode, the indoor fan runs continuously even if the compressor stops running.

Timer

By this feature we can set the operating time of the air conditioner from one(1) hour up to a time of 12 hours. In the “Off” mode, the Air Conditioner stops operating after the set time, while in the “On” mode, the Air Conditioner timer can be set so that the unit starts operating at the desired time.

Features

Electric Heater

Electric heaters are used in cold regions when instant heating is required in the room.

In such cases, electric heaters are preferred over heat pump models which sometime require long time to achieve the desired heating effect.

Electric Heater are of two types – Coil Heater and PTC Heater Fig : Coil Heater

6RWU0-03A

Fig : PTC Heater

Deice Control

When the unit starts operating in the heating mode, then, to protect the outdoor unit pipe from freezing, “deice” control is used. By exercising this control, the cycle is reversed into the cooling mode; to deice or defrost the condenser tubes in the outdoor unit.

Air Ventilation

Air ventilation is carried out by means of a ventilation lever from time to time to induct fresh air into the room. For the air conditioner to maintain the best cooling conditions, the lever must be in the closed position. And when the ventilation lever is set in the open position, the damper opens and the room air is exhausted while at the same time fresh air from outside enters the room.

VENT

OPEN

VENT

CLOSE

Energy saving Gold Fin

Heat exchangers are coated with anti-corrosive and Hydrophilic layers. It prevents the corrosion of heat exchanger.

Fins remain new for a long time and the efficiency of the heat exchanger remains constant thereby saving power and maintenance cost.

Uncoated

Aluminum

Salt Spray Test Result : After 360 hours

[ Test Standard: ASTM B-117, KS D 9502 ]

Anti Corrosion Gold Fin

Hydrophilic

layer

Anticorrosion

layer

Aluminum

[ Aluminum]

Pitting Corrosion

10 mm 10 mm

• Pitting corrosion on the surface

Anti Corrosion Gold Fin

No corrosion

Gold Fin Anti-Corrosive Treatment:

6RWU0-03A Features

Infinite Impulse response (IIR)

The IIR function senses the temperature several times per second and make micro adjustments accordingly.

Compressor Restart Delay

This feature extends the overall life of the compressor by preventing the short cycling of the air-conditioner. When the compressor restarts, LG PTAC is designed to give it a minimum of three minutes to have a time of equalizing the refrigerant pressures for optimizing the cycle.

Fan only setting

When the Fan only setting is made, only the fan on the indoor side operates while the compressor stops operating and the unit ceases to run in the Cooling or the Heating mode.

Indoor Fan speed setting

The Indoor fan can run at HIGH or LOW speed for either COOLING or HEATING operation.

Two Fan motors

The air conditioning unit has two fan motors for providing a quiet operation and maximum efficiency.

LED Diagnostics and Self Diagnostics

LED Diagnostics feature indicates the problem by its easy to read diagnostics, when the unit does not operate properly. For example, one blink every 2 seconds indicate compressor failure.

While Self Diagnostics feature is used in micom models and it indicates the problem by a displaying a set of error codes.

2 position discharge grille

The discharge grille can provide air flow upwards at an angle of 40˚ off vertical or 15˚ off vertical. The angle is changed by removing the front grille and 4 screws that fasten the discharge grille to the front grille and rotating the louvers to an alternate position.

Indoor room freeze protection

When the unit senses the room temperature to be less than 40˚ F, the unit activates the fan motor and either the electric resistance heater or the hydronic heater, to prevent the pipes or fixtures from freezing. This also overrides the front desk control of the unit mounted controls or the wall mounted controls.

Door Switch/Occupancy Sensor

The unit is capable of accommodating a field installed door switch and occupancy sensor to operate the energy management feature by checking whether any people are present inside the room or not. If there are no people inside the room, the energy management feature is in play.

Compressor Overload protection

This feature prevents damage of the compressor by sensing the indoor coil temperature during the heating mode. If the indoor coil temperature is over 130˚ F, the outdoor fan is switched off and it operates again only when the temperature drops below 120 ˚ F.

Features 6RWU0-03A

Outdoor Air Temperature switchover

This feature changes the operating mode of the unit from the heat pump mode to total resistance heat.

Temperature limits

The unit is programmed to provide both heating and cooling temperature limits by dip switches on the control panel. The limits are from 50˚ F to 90˚ F. These temperature limits help to prevent overheating and overcooling thereby reducing the energy costs.

Condensate Drain Valve

The unit has a condensate drain valve to prevent water from collecting and freezing in the basepan.

Quick Heater Recovery

The unit is designed to operate the electric heater so as to warm the room to the desired temperature set point as soon as the Heat Pump cycle operates. This feature has an advantage of reducing the time to reach the desired temperature for better comfort.

Reverse Cycle Defrosting – (PTHPʼs only)

This feature enables the unit to activate the reverse cycle defrost so as to prevent the formation of ice on the outdoor unit, which is exposed to cold environment. Formation of ice reduces the airflow through the coil and hence the efficiency of the air conditioning unit. The LG PTHP employs an active reverse cycle defrost function to melt the ice off the outdoor coil for ensuring room comfort conditions and savings from extended operation.

High Temperature Heat Pump Operation Protection

When the unit operates at high outdoor temperature conditions during the cooling cycle, this feature switches off the compressor to prevent damage.

Remote Thermostat Control

The PTAC air conditioning unit is designed and built to be operated from any four(4) or five(5) wire remote mounted thermostat if desired. The unit has a builtin low voltage power source which can accommodate any of the thermostat choices – manual, auto changeover or programmable. A remote thermostat can also be added to any unit.

Zone Sensor

The PTAC air conditioning unit can be controlled by means of a Zone Sensor which carries out the same functions as that of a Wall Thermostat. In other words, it is a remote wall thermostat.

6RWU0-03A

Part 2 Product data

1 YA chassis ...........................................................................................22

1.1 Features ...........................................................................................................22

1.2 List of functions ................................................................................................23

1.3 Specifications ...................................................................................................24

1.4 Dimensions.......................................................................................................30

1.5 Piping diagrams................................................................................................31

1.6 Wiring diagrams................................................................................................33

1.7 Capacity tables ..................................................................................................35

1.8 Electrical characteristics ....................................................................................43

1.9 Operation range.................................................................................................44

2 Control Devices..................................................................................45

2.1 Electronic Controls ...........................................................................................45

6RWU0-03A

1. YA Chassis

YA Chassis

Models : UYC073ALE21(LP073CD2B)

UYH073ALE21(LP073HD2B)

UYC093ALE31(LP093CD3B)

UYH093ALE31(LP093HD3B)

UYC09EALE31(LP096CD3B)

UYH09EALE31(LP096HD3B)

UYC123ALE31(LP123CD3B)

UYH123ALE31(LP123HD3B)

UYC12EALE31(LP126CD3B)

UYH12EALE31(LP126HD3B)

UYC153ALE31(LP153CD3B)

UYH153ALE31(LP153HD3B)

1.1 Features n 2 -Way Air Flow Direction n

Washable Filters n Low Noise at High Air Volume n

High Efficiency Compressor n

Energy Saver Mode n Timer n

Electric Heater n Deice Control n Air Ventilation n

Energy saving Anti-corrosion treated Fins n Infinite Impulse Response(IIR) n

Compressor Restart Delay n Fan only Setting n Indoor Fan Speed Setting n Two Fan Motors n

LED Diagnostics and Self Diagnostics n 2 Position Discharge Grille n Indoor Room Freeze Protection n

Door Switch/Occupancy Sensor n Compressor Overload Protection n

Outdoor Air Temperature Switchover n

Temperature Limits n Condensate Drain Valve n

Quick Heater Recovery n Reverse Cycle Defrosting (PTHPʼs only) n High Temperature Heat Pump operation Protection n

Remote Thermostat Control n Zone Sensor

YA Chassis

1.2 List of functions

6RWU0-03A

Category Function

Air flow Air discharge type

Airflow direction control (up & down)

Airflow direction control (left & right)

Auto swing

Airflow steps (fan/cool/heat)

Airflow Direction

Air purifying Deodorizing filter

Plasma air filter

Air filter (washable / anti-fungus)

Installation Electric heater (operation)

Reliability Hot start

Convenience Auto restart operation

Micom control

Air ventilation

Forced operation

Sleep mode

Timer

Individual control Wired remote controller

Wireless remote controller

Wireless LCD remote control

Others Energy saver switch

Thermostat

Thermistor

Note :

O : applied

- : not applied

PTAC

Cooling only Models

PTAC

Heat Pump Models

Top discharge Top discharge

Manual Manual

- -

- -

2/2/2 2/2/2

2 way 2 way

- -

- -

O O

O O

- -

O O

O O

O O

- -

- -

O O

O O

O O

O O

O O

- -

O O

6RWU0-03A

1.3 Specifications

208-230V COOLING ONLY MODELS

Buyer Models

LG Models

Cooling Capacity

Heating Capacity ( for Heat Pump models)

Electric Heater capacity

Power Input Cooling/Heating

Running Current Cooling/Heating

Electric Heater Current

EER

COP

Power Supply

Power Factor

MCA

MOP

Air Flow Rate

Indoor,(H/L)

Outdoor,Max

Dehumidification

Sound Level

Indoor,H/M/L

Outdoor,Max

Refrigerant & Charge

Type

Model

Compressor

Motor Type

Oil Type

Oil Charge

RLA/LRA

O.L.P Name

Type(In/Out)

Motor Type(In/Out)

Fan

Heat Exchanger

FLA(In/Out)

Motor Output(In/Out)

Evaporator

Condensor

Power Supply Cable (Power Cord) cc

A

Dimensions ( W * H * D)

A

W

Rows * Column * FPI

Rows * Column * FPI

No. * AWG mm inch kg(lbs) Net Weight

Tool Code(Chassis)

Features

Operating Range Voltage (Min/Max)

Temperature Control

Energy Saver Mode

Prefilter(washable/anti-fungus)

Plasma Filter

Steps, Fan/Cool/Heat

Airflow Direction Control(up&down)

Airflow Direction Control(left&right)

Remote Controller Type

Setting Temperature

Range

Cooling

Heating

Auto Operation (Micom Control)

Panel Touch Type

Timer

Air Discharge

Air-Ventilation

Deice Control(Defrost)

Hot Start

Look

Cabinet Type(Chassis Type)

Special Function kW

Btu/h.

kW

Btu/h.

kW

Btu/h.

W

A

A

W/W

Btu/h.W

W/W

Ø / V / Hz

%

A

A m 3 /min(CFM) m 3 /min(CFM) pts/h dB(A)±3 dB(A)±3 g(oz)

Note : -

○ : applied

- : not applied

YA Chassis

2.08

7,100

-

-

LP073CD2B

UYC073ALE21

2.14

7,300

-

-

2.4

8,200

535

2.7

11.5

3.90

13.3

-

2.5

8,600

550

2.5

10.9

3.90

13.3

-

2.73

9,300

-

-

3.1

10,500

730

3.7

14.9

3.72

12.7

-

LP093CD3B

UYC093ALE31

1 / 208 / 60 1 / 230 / 60 1 / 208 / 60

95 96 95

14.9

15.0

7.6(270)/6.3(225)

17(600)

1.7

19.5

20.0

7.6(270)/6.3(225)

17(600)

2.6

2.78

9,500

-

-

3.5

11,900

745

3.4

15.2

3.72

12.7

-

1 / 230 / 60

95

45/-/43

61

R410A, 740(26.1)

Rotary(Non Tropical)

GA060KAA

PSC

POE(RB68A)orPVE(FVC68D)

310

2.9/16

B120-160-241E

Cross Flow Fan Axial Fan

46/-/44

61

R410A,600(21.2)

Rotary(Non Tropical)

GA080KBA

PSC

POE(RB68A)orPVE(FVC68D)

230

3.7/19

B145-155-241E

Cross Flow Fan Axial Fan

BLDC/BLDC

0.36/0.36

20/65

2R *12C *18FPI

3R *17C *20FPI

3 * 12

1,066 * 406 * 537

42 * 16 * 21

43(95)

YA

187/253

Thermistor

O

O

-

2/2/2

Manual

-

Wall Thermostat

54℉ ~ 86℉(12.2℃ ~ 30℃)

54℉ ~ 86℉(12.2℃ ~ 30℃)

O

Micom

12h, On/Off

Top

O

-

-

L - Look

Slide In-Out

Electric Heater

BLDC/BLDC

0.36/0.36

26/66

2R *10C *19FPI

3R *17C *20FPI

3 * 12

1,066 * 406 * 537

42 * 16 * 21

43(95)

YA

187/253

Thermistor

O

O

-

2/2/2

Manual

-

Wall Thermostat

54℉ ~ 86℉(12.2℃ ~ 30℃)

54℉ ~ 86℉(12.2℃ ~ 30℃)

O

Micom

12h, On/Off

Top

O

-

-

L - Look

Slide In-Out

Electric Heater

YA Chassis 6RWU0-03A

Buyer Models

LG Models

Cooling Capacity

Heating Capacity ( for Heat Pump models)

Electric Heater capacity

Power Input Cooling/Heating

Running Current Cooling/Heating

Electric Heater Current

EER

COP

Power Supply

Power Factor

MCA

MOP

Air Flow Rate

Indoor,(H/L)

Outdoor,Max

Dehumidification

Sound Level

Indoor,H/M/L

Outdoor,Max

Refrigerant & Charge

Type

Model

Compressor

Motor Type

Oil Type

Oil Charge

RLA/LRA

O.L.P Name

Type(In/Out)

Motor Type(In/Out)

Fan

Heat Exchanger

FLA(In/Out)

Motor Output(In/Out)

Evaporator

Condensor

Power Supply Cable (Power Cord) cc

A

Dimensions ( W * H * D)

A

W

Rows * Column * FPI

Rows * Column * FPI

No. * AWG mm inch kg(lbs) Net Weight

Tool Code(Chassis)

Features

Operating Range Voltage (Min/Max)

Temperature Control

Energy Saver Mode

Prefilter(washable/anti-fungus)

Plasma Filter

Steps, Fan/Cool/Heat

Airflow Direction Control(up&down)

Airflow Direction Control(left&right)

Remote Controller Type

Setting Temperature

Range

Cooling

Heating

Auto Operation (Micom Control)

Panel Touch Type

Timer

Air Discharge

Air-Ventilation

Deice Control(Defrost)

Hot Start

Look

Cabinet Type(Chassis Type)

Special Function kW

Btu/h.

kW

Btu/h.

kW

Btu/h.

W

A

A

W/W

Btu/h.W

W/W

Ø / V / Hz

%

A

A m 3 /min(CFM) m 3 /min(CFM) pts/h dB(A)±3 dB(A)±3 g(oz)

Note : -

: applied

- : not applied

3.52

12,000

LP123CD3B

UYC123ALE31

3.58

12,200

-

-

3.1

-

-

3.5

10,500

1,005

5.1

14.9

11,900

1,025

4.7

15.2

3.49

11.9

-

1 / 208 / 60

95

3.49

11.9

-

1 / 230 / 60

95

19.5

20.0

11.9(420)/10.0(353)

20(706)

3.0

50/-/48

63

R410A, 610(21.5)

Rotary(Non Tropical)

PA108M1C

PSC

ESTER OIL VG74

350

5.0/27

BF910-MA

Cross Flow Fan Axial Fan

BLDC/BLDC

0.36/0.36

41/74

2R *10C *19FPI

3R *17C *20FPI

3 * 12

1,066 * 406 * 537

42 * 16 * 21

45(99)

YA

187/253

Thermistor

O

O

-

2/2/2

Manual

-

Wall Thermostat

54℉ ~ 86℉(12.2℃ ~ 30℃)

54℉ ~ 86℉(12.2℃ ~ 30℃)

O

Micom

12h, On/Off

Top

O

-

-

L - Look

Slide In-Out

Electric Heater

LP153CD3B

4.37

UYC153ALE31

14,900

4.43

15,100

-

-

3.1

-

-

3.5

10,500

1,330

6.6

14.9

3.28

11.2

-

1 / 208 / 60

97

11,900

1,345

6.1

15.2

3.28

11.2

-

1 / 230 / 60

96

19.5

20.0

11.9(420)/10.0(353)

20(706)

4.3

51/-/49

64

R410A, 910(32.1)

Rotary(Non Tropical)

PA140M2C

PSC

ESTER OIL VG74

440

6.55/38.6

INTERNAL

Cross Flow Fan

BLDC/BLDC

0.36/0.36

Axial Fan

41/74

2R *10C *19FPI

3R *17C *20FPI

3 * 12

1,066 * 406 * 537

42 * 16 * 21

52(115)

YA

187/253

Thermistor

O

O

-

2/2/2

Manual

-

Wall Thermostat

54℉ ~ 86℉(12.2℃ ~ 30℃)

54℉ ~ 86℉(12.2℃ ~ 30℃)

O

Micom

12h, On/Off

Top

O

-

-

L - Look

Slide In-Out

Electric Heater

6RWU0-03A YA Chassis

208-230V HEAT PUMP MODELS

Buyer Models

LG Models

Cooling Capacity

Heating Capacity ( for Heat Pump models)

Electric Heater capacity

Power Input Cooling/Heating

Running Current Cooling/Heating

Electric Heater Current

EER

COP

Power Supply

Power Factor

MCA

MOP

Air Flow Rate

Indoor,(H/L)

Outdoor,Max

Dehumidification

Sound Level

Indoor,H/M/L

Outdoor,Max

Refrigerant & Charge

Type

Model

Compressor

Motor Type

Oil Type

Oil Charge

RLA/LRA

O.L.P Name

Type(In/Out)

Motor Type(In/Out)

Fan

Heat Exchanger

FLA(In/Out)

Motor Output(In/Out)

Evaporator

Condensor

Power Supply Cable (Power Cord) cc

A

Dimensions ( W * H * D)

A

W

Rows * Column * FPI

Rows * Column * FPI

No. * AWG mm inch kg(lbs) Net Weight

Tool Code(Chassis)

Features

Operating Range Voltage (Min/Max)

Temperature Control

Energy Saver Mode

Prefilter(washable/anti-fungus)

Plasma Filter

Steps, Fan/Cool/Heat

Airflow Direction Control(up&down)

Airflow Direction Control(left&right)

Remote Controller Type

Setting Temperature

Range

Cooling

Heating

Auto Operation (Micom Control)

Panel Touch Type

Timer

Air Discharge

Air-Ventilation

Deice Control(Defrost)

Hot Start

Look

Cabinet Type(Chassis Type)

Special Function kW

Btu/h.

kW

Btu/h.

kW

Btu/h.

W

A

A

W/W

Btu/h.W

W/W

Ø / V / Hz

%

A

A m 3 /min(CFM) m 3 /min(CFM) pts/h dB(A)±3 dB(A)±3 g(oz)

Note : -

: applied

- : not applied

2.08

7,100

1.82

6,200

2.4

8,200

535/500

2.7/2.6

11.5

3.90

13.3

3.6

LP073HD2B

UYH073ALE21

2.14

7,300

1.88

6,400

2.5

8,600

550/520

2.5/2.4

10.9

3.90

13.3

3.6

2.73

9,300

2.34

8,000

3.1

10,500

720/655

3.6/3.3

14.9

3.78

12.9 12.9

3.6

LP093HD3B

UYH093ALE31

2.78

9,500

2.40

8,200

3.5

11,900

735/670

3.3/3.0

15.2

3.78

3.6

1 / 208 / 60 1 / 230 / 60 1 / 208 / 60 1 / 230 / 60

95 96 96 97

14.9

15.0

19.5

20.0

7.6(270)/6.3(225)

17(600)

1.7

45/-/43

61

R410A, 740(26.1)

7.6(270)/6.3(225)

17(600)

2.6

46/-/44

61

R410A, 910(32.1)

Rotary(Non Tropical)

GA060KAA

PSC

POE(RB68A)orPVE(FVC68D)

310

2.9/16

B120-160-241E

Cross Flow Fan Axial Fan

BLDC/BLDC

0.36/0.36

20/65

2R *12C *18FPI

3R *17C *20FPI

3 * 12

1,066 * 406 * 537

42 * 16 * 21

43(95)

YA

187/253

Thermistor

O

O

-

2/2/2

Manual

-

Wall Thermostat

54℉ ~ 86℉(12.2℃ ~ 30℃)

54℉ ~ 86℉(12.2℃ ~ 30℃)

O

Micom

12h, On/Off

Top

O

O

-

L - Look

Slide In-Out

Electric Heater

Rotary(Non Tropical)

GKU086KAB

PSC

POE(RB68A)orPVE(FVC68D)

330

4.0/19

LMSH2Z69-L002

Cross Flow Fan

BLDC/BLDC

0.36/0.36

26/66

Axial Fan

2R *10C *19FPI

3R *17C *20FPI

3 * 12

1,066 * 406 * 537

42 * 16 * 21

48(106)

YA

187/253

Thermistor

O

O

-

2/2/2

Manual

-

Wall Thermostat

54℉ ~ 86℉(12.2℃ ~ 30℃)

54℉ ~ 86℉(12.2℃ ~ 30℃)

O

Micom

12h, On/Off

Top

O

O

-

L - Look

Slide In-Out

Electric Heater

YA Chassis 6RWU0-03A

Buyer Models

LG Models

Cooling Capacity

Heating Capacity ( for Heat Pump models)

Electric Heater capacity

Power Input Cooling/Heating

Running Current Cooling/Heating

Electric Heater Current

EER

COP

Power Supply

Power Factor

MCA

MOP

Air Flow Rate

Indoor,(H/L)

Outdoor,Max

Dehumidification

Sound Level

Indoor,H/M/L

Outdoor,Max

Refrigerant & Charge

Type

Model

Compressor

Motor Type

Oil Type

Oil Charge

RLA/LRA

O.L.P Name

Type(In/Out)

Motor Type(In/Out)

Fan

Heat Exchanger

FLA(In/Out)

Motor Output(In/Out)

Evaporator

Condensor

Power Supply Cable (Power Cord) cc

A

Dimensions ( W * H * D)

A

W

Rows * Column * FPI

Rows * Column * FPI

No. * AWG mm inch kg(lbs) Net Weight

Tool Code(Chassis)

Features

Operating Range Voltage (Min/Max)

Temperature Control

Energy Saver Mode

Prefilter(washable/anti-fungus)

Plasma Filter

Steps, Fan/Cool/Heat

Airflow Direction Control(up&down)

Airflow Direction Control(left&right)

Remote Controller Type

Setting Temperature

Range

Cooling

Heating

Auto Operation (Micom Control)

Panel Touch Type

Timer

Air Discharge

Air-Ventilation

Deice Control(Defrost)

Hot Start

Look

Cabinet Type(Chassis Type)

Special Function kW

Btu/h.

kW

Btu/h.

kW

Btu/h.

W

A

A

W/W

Btu/h.W

W/W

Ø / V / Hz

%

A

A m 3 /min(CFM) m 3 /min(CFM) pts/h dB(A)±3 dB(A)±3 g(oz)

Note : -

: applied

- : not applied

3.52

12,000

LP123HD3B

UYH123ALE31

3.58

12,200

3.11

10,600

3.17

10,800

3.1

10,500

1,010/885

5.2/4.6

14.9

3.5

11,900

1,025/905

4.8/4.3

15.2

LP153HD3B

4.37

UYH153ALE31

14,900

4.43

15,100

3.87

13,200

3.93

13,400

3.1

10,500

1,330/1250

6.6/6.2

14.9

3.5

11,900

1,345/1265

6.1/5.7

15.2

3.49

11.9

3.5

3.49

11.9

3.5

3.28

11.2

3.1

1 / 208 / 60 1 / 230 / 60 1 / 208 / 60

93 93 97

19.5

20.0

11.9(420)/10.0(353)

20(706)

3.0

19.5

20.0

11.9(420)/10.0(353)

20(706)

4.3

3.28

11.2

3.1

1 / 230 / 60

96

50/-/48

63

R410A, 850(30.0)

Rotary(Non Tropical)

GKU113KAB

PSC

POE(RB68A) or PVE(FVC68D)

330

5.0/26

MRA98996-12026

Cross Flow Fan Axial Fan

51/-/49

64

R410A, 910(32.1)

Rotary(Non Tropical)

PA140M2C

PSC

ESTER OIL VG74

440

6.55/38.6

INTERNAL

Cross Flow Fan Axial Fan

BLDC/BLDC

0.36/0.36

41/74

2R *10C *19FPI

3R * 17C * 20FPI

3 * 12

1,066 * 406 * 537

42 * 16 * 21

48(106)

BLDC/BLDC

0.36/0.36

41/74

2R *10C *19FPI

3R *17C *20FPI

3 * 12

1,066 * 406 * 537

42 * 16 * 21

52(115)

YA

187/253

Thermistor

O

O

-

2/2/2

Manual

-

Wall Thermostat

54℉ ~ 86℉(12.2℃ ~ 30℃)

54℉ ~ 86℉(12.2℃ ~ 30℃)

O

Micom

12h, On/Off

Top

O

O

-

L - Look

Slide In-Out

Electric Heater

YA

187/253

Thermistor

O

O

-

2/2/2

Manual

-

Wall Thermostat

54℉ ~ 86℉(12.2℃ ~ 30℃)

54℉ ~ 86℉(12.2℃ ~ 30℃)

O

Micom

12h, On/Off

Top

O

O

-

L - Look

Slide In-Out

Electric Heater

6RWU0-03A YA Chassis

265V COOLING ONLY MODELS

Buyer Models

LG Models

Cooling Capacity

Heating Capacity ( for Heat Pump models)

Electric Heater capacity

Power Input Cooling/Heating

Running Current Cooling/Heating

Electric Heater Current

EER

COP

Power Supply

Power Factor

MCA

MOP

Air Flow Rate

Indoor,(H/L)

Outdoor,Max

Dehumidification

Sound Level

Indoor,H/M/L

Outdoor,Max

Refrigerant & Charge

Type

Model

Compressor

Motor Type

Oil Type

Oil Charge

RLA/LRA

O.L.P Name

Type(In/Out)

Motor Type(In/Out)

Fan

Heat Exchanger

FLA(In/Out)

Motor Output(In/Out)

Evaporator

Condensor

Power Supply Cable (Power Cord) cc

A

Dimensions ( W * H * D)

A

W

Rows * Column * FPI

Rows * Column * FPI

No. * AWG mm inch kg(lbs) Net Weight

Tool Code(Chassis)

Features

Operating Range Voltage (Min/Max)

Temperature Control

Energy Saver Mode

Prefilter(washable/anti-fungus)

Plasma Filter

Steps, Fan/Cool/Heat

Airflow Direction Control(up&down)

Airflow Direction Control(left&right)

Remote Controller Type

Setting Temperature

Range

Cooling

Heating

Auto Operation (Micom Control)

Panel Touch Type

Timer

Air Discharge

Air-Ventilation

Deice Control(Defrost)

Hot Start

Look

Cabinet Type(Chassis Type)

Special Function kW

Btu/h.

kW

Btu/h.

kW

Btu/h.

W

A

A

W/W

Btu/h.W

W/W

Ø / V / Hz

%

A

A m 3 /min(CFM) m 3 /min(CFM) pts/h dB(A)±3 dB(A)±3 g(oz)

Note : -

: applied

- : not applied

LP096CD3B

UYC09EALE31

2.84

9,700

-

-

3.7

12,600

755

3.0

14.0

3.75

12.8

-

1 / 265 / 60

95

17.9

20

7.6(270)/6.3(225)

17(600)

2.6

46/-/44

61

R410A, 895(31.6)

Rotary(Non Tropical)

GKU086QAA

PSC

POE(RB68A) or PVE(FVC68D)

330

3.3/20

LPMD2W69-L002

Cross Flow Fan Axial Fan

BLDC/BLDC

0.36/0.36

26/66

2R *10C *19FPI

3R *17C *20FPI

3 * 12

1,066 * 406 * 537

42 * 16 * 21

48(106)

YA

239/292

Thermistor

O

O

-

2/2/2

Manual

-

Wall Thermostat

54℉ ~ 86℉(12.2℃ ~ 30℃)

54℉ ~ 86℉(12.2℃ ~ 30℃)

O

Micom

12h, On/Off

Top

O

-

-

L - Look

Slide In-Out

Coil Heater

LP126CD3B

UYC12EALE31

3.58

12,200

-

-

3.7

12,600

1,025

4.0

14.0

3.49

11.9

-

1 / 265 / 60

97

17.9

20

11.9(420)/10.0(353)

20(706)

3.0

50/-/48

63

R410A, 910(32.1)

Rotary(Non Tropical)

GKU113QAA

PSC

POE(RB68A) or PVE(FVC68D)

330

4.4/22

LMSH2Z69-L002

Cross Flow Fan Axial Fan

BLDC/BLDC

0.36/0.36

41/74

2R *10C *19FPI

3R *17C *20FPI

3 * 12

1,066 * 406 * 537

42 * 16 * 21

48(106)

YA

239/292

Thermistor

O

O

-

2/2/2

Manual

-

Wall Thermostat

54℉ ~ 86℉(12.2℃ ~ 30℃)

54℉ ~ 86℉(12.2℃ ~ 30℃)

O

Micom

12h, On/Off

Top

O

-

-

L - Look

Slide In-Out

Coil Heater

YA Chassis 6RWU0-03A

265V HEAT PUMP MODELS

Buyer Models

LG Models

Cooling Capacity

Heating Capacity ( for Heat Pump models)

Electric Heater capacity

Power Input Cooling/Heating

Running Current Cooling/Heating

Electric Heater Current

EER

COP

Power Supply

Power Factor

MCA

MOP

Air Flow Rate

Indoor,(H/L)

Outdoor,Max

Dehumidification

Sound Level

Indoor,H/M/L

Outdoor,Max

Refrigerant & Charge

Type

Model

Compressor

Motor Type

Oil Type

Oil Charge

RLA/LRA

O.L.P Name

Type(In/Out)

Motor Type(In/Out)

Fan

Heat Exchanger

FLA(In/Out)

Motor Output(In/Out)

Evaporator

Condensor

Power Supply Cable (Power Cord) cc

A

Dimensions ( W * H * D)

A

W

Rows * Column * FPI

Rows * Column * FPI

No. * AWG mm inch kg(lbs) Net Weight

Tool Code(Chassis)

Features

Operating Range Voltage (Min/Max)

Temperature Control

Energy Saver Mode

Prefilter(washable/anti-fungus)

Plasma Filter

Steps, Fan/Cool/Heat

Airflow Direction Control(up&down)

Airflow Direction Control(left&right)

Remote Controller Type

Setting Temperature

Range

Cooling

Heating

Auto Operation (Micom Control)

Panel Touch Type

Timer

Air Discharge

Air-Ventilation

Deice Control(Defrost)

Hot Start

Look

Cabinet Type(Chassis Type)

Special Function kW

Btu/h.

kW

Btu/h.

kW

Btu/h.

W

A

A

W/W

Btu/h.W

W/W

Ø / V / Hz

%

A

A m 3 /min(CFM) m 3 /min(CFM) pts/h dB(A)±3 dB(A)±3 g(oz)

Note : -

: applied

- : not applied

LP096HD3B

UYH09EALE31

2.84

9,700

2.49

8,500

3.7

12,600

755/690

3.0/2.7

14.0

3.75

12.8

3.6

1 / 265 / 60

95

17.9

20

7.6(270)/6.3(225)

17(600)

2.6

46/-/44

61

R410A, 895(31.6)

Rotary(Non Tropical)

GKU086QAA

PSC

POE(RB68A) or PVE(FVC68D)

330

3.3/20

LPMD2W69-L002

Cross Flow Fan Axial Fan

BLDC/BLDC

0.36/0.36

26/66

2R *10C *19FPI

3R *17C *20FPI

3 * 12

1,066 * 406 * 537

42 * 16 * 21

48(106)

YA

239/292

Thermistor

O

O

-

2/2/2

Manual

-

Wall Thermostat

54℉ ~ 86℉(12.2℃ ~ 30℃)

54℉ ~ 86℉(12.2℃ ~ 30℃)

O

Micom

12h, On/Off

Top

O

O

-

L - Look

Slide In-Out

Coil Heater

LP126HD3B

UYH12EALE31

3.58

12,200

3.22

11,000

3.7

12,600

1,025/895

4.0/3.5

14.0

3.49

11.9

3.6

1 / 265 / 60

97

17.9

20

11.9(420)/10.0(353)

20(706)

3.0

50/-/48

63

R410A, 910(32.1)

Rotary(Non Tropical)

GKU113QAA

PSC

POE(RB68A) or PVE(FVC68D)

330

4.4/22

LMSH2Z69-L002

Cross Flow Fan Axial Fan

BLDC/BLDC

0.36/0.36

41/74

2R *10C *19FPI

3R *17C *20FPI

3 * 12

1,066 * 406 * 537

42 * 16 * 21

48(106)

YA

239/292

Thermistor

O

O

-

2/2/2

Manual

-

Wall Thermostat

54℉ ~ 86℉(12.2℃ ~ 30℃)

54℉ ~ 86℉(12.2℃ ~ 30℃)

O

Micom

12h, On/Off

Top

O

O

-

L - Look

Slide In-Out

Coil Heater

6RWU0-03A

1.4 Dimensions

YA Chassis

406mm (16")

406mm (16")

YA Chassis

1.5 Piping diagrams

Models : UYC073ALE21(LP073CD2B)

UYC093ALE31(LP093CD3B)

UYC123ALE31(LP123CD3B)

UYC153ALE31(LP153CD3B)

UYC09EALE31(LP096CD3B)

UYC12EALE31(LP126CD3B)

Liquid side

Capillary Tube

Th1

Th2

Heat

Exchanger

(Evaporator)

C.F.F

Axial Fan

Gas side

Compressor

H/P

High Pressure S/W

: 41.8/32.6(kgf/cm 2 G)

[595/463(lbf/in 2 G)]

LOC. Description PCB Connector

Th1 Thermistor for indoor Air temperature CN-IDAT2

Th2 Thermistor for evaporator temperature CN-IDPT

6RWU0-03A

Heat

Exchanger

(Condenser)

6RWU0-03A

Models : UYH073ALE21(LP073HD2B)

UYH093ALE31(LP093HD3B)

UYH123ALE31(LP123HD3B)

UYH153ALE31(LP153HD3B)

UYH09EALE31(LP096HD3B)

UYH12EALE31(LP126HD3B)

YA Chassis

Th1

Th2

HEAT

EXCHANGER

(EVAPORATOR)

Th1

Th2

Heat

Exchanger

(Evaporator)

CAPILLARY TUBE

(HEAT)

CAPILLARY TUBE

(COOL)

CHECK VALVE

Capi

Th3

Th4

HEAT

EXCHANGER

(CONDENSER)

C.F.F.

Heat

Exchanger

(Condense

ACCUMULATOR

Accumulator

Compressor

Axial Fan

REVERSING VALVE Th4

H/P Th3

: 41.8/32.6(kgf/cm 2 G)

[595/463 (lbf/in 2 G)

Reversing Valve

Cooling

Heating

LOC. Description PCB Connector

Th1 Thermistor for indoor air temperature CN-IDAT2

CN-IDPT Th2 Thermistor for evaporator temperature

Th3 Thermistor for outdoor air temperature

Th4 Thermistor for condenser temperature

CN-ODT

YA Chassis

1.6 Wiring diagrams

6RWU0-03A

Models : UYC073ALE21(LP073CD2B)

UYH073ALE21(LP073HD2B)

UYC093ALE31(LP093CD3B)

UYH093ALE31(LP093HD3B)

UYC09EALE31(LP096CD3B)

UYH09EALE31(LP096HD3B)

UYC123ALE31(LP123CD3B)

UYH123ALE31(LP123HD3B)

UYC12EALE31(LP126CD3B)

UYH12EALE31(LP126HD3B)

UYC153ALE31(LP153CD3B)

UYH153ALE31(LP153HD3B)

BK1

BK2

BK3

BK4

RD

BL

RD

BL

TB1

WH

POWER INPUT

NEUTRAL

WH

LIVE

BK

GN/YL

OR

TB2

OR BK

INDOOR AIR THERMISTOR

INDOOR COIL THERMISTOR

OUTDOOR AIR THERMISTOR

OUTDOOR COIL THERMISTOR

CN-THERMO-S CN-AUX-S CN-IDPT CN-ODT

CN-IDAT2

Pressure

Switch

BK BK

BK BK

BK

BK

F

HERM

R

COMP S

C

OLP

BL

RD

BR

MAIN PWB.ASM

WCN-NOISE

YL

BL

WH

BK

RD

YL

BL

WH

BK

RD

YL

BL

WH

BK

RD

YL

BL

WH

BK

RD

INDOOR

FAN

MOTOR

OUTDOOR

FAN

MOTOR

WH

BK

CN-CC_S

CN-CC

CN-WRITE_S

CN-WRITE

6RWU0-03A

CN-PRESS

CN-AUX-S

CN-THERMO-S CN-IDPT

CN-ODT

CN-IDAT2

CN-DISP1

CN-DISP2

CN-WRITE

CN-4WAY

CN-ICR

CN-EXT(L)

CN-EXT(N)

CN-DIP

CN-MOTOR_IDF

CN-MOTOR_ODF

CN-N

YA Chassis

YA Chassis

1.7 Capacity tables

Cooling Capacity

UYC073ALE21(LP073CD2B)

6RWU0-03A

Temperature

68 77 89.6

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

60.8 71.6

5.92 5.80 0.36 5.80 5.88 0.43 5.52 6.00 0.50

6.91 5.65 0.37 6.76 5.71 0.44 6.44 5.82 0.51

64.4 77.0

66.2 80.6

7.71 5.51 0.37 7.55 5.56 0.44 7.19 5.66 0.52

8.07 5.44 0.38 7.90 5.49 0.45 7.52 5.58 0.52

71.6 86.0

75.2 89.6

8.85 5.26 0.38 8.67 5.30 0.46 8.26 5.38 0.53

9.19 5.15 0.39 8.99 5.19 0.46 8.57 5.25 0.54

Temperature

95 104 109.4

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

5.36 6.06 0.53 5.16 6.15 0.56 4.99 6.21 0.58

60.8 71.6

64.4 77.0

6.25 5.87 0.54 6.02 5.95 0.57 5.82 6.00 0.59

6.98 5.70 0.54 6.72 5.77 0.58 6.50 5.82 0.60

66.2 80.6

71.6 86.0

7.30 5.62 0.55 7.03 5.69 0.59 6.80 5.73 0.61

8.01 5.41 0.56 7.71 5.46 0.60 7.46 5.49 0.62

75.2 89.6

8.31 5.28 0.57 8.00 5.33 0.60 7.74 5.36 0.62

UYC093ALE31(LP093CD3B)

Temperature

68 77 89.6

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

7.71 7.43 0.49 7.54 7.52 0.58 7.19 7.67 0.67

60.8 71.6

64.4 77.0

8.99 7.23 0.50 8.80 7.31 0.59 8.39 7.45 0.69

10.03 7.04 0.50 9.82 7.12 0.60 9.36 7.24 0.70

66.2 80.6

71.6 86.0

10.50 6.96 0.51 10.28 7.03 0.61 9.79 7.14 0.71

11.52 6.72 0.52 11.28 6.78 0.61 10.75 6.88 0.72

75.2 89.6

11.96 6.59 0.53 11.70 6.64 0.62 11.15 6.72 0.73

Temperature

95 104 109.4

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

60.8 71.6

6.97 7.75 0.71 6.71 7.87 0.76 6.49 7.94 0.78

8.14 7.51 0.72 7.83 7.62 0.77 7.58 7.68 0.79

64.4 77.0

66.2 80.6

9.08 7.29 0.73 8.74 7.39 0.78 8.45 7.44 0.80

9.50 7.19 0.75 9.15 7.28 0.79 8.85 7.33 0.82

71.6 86.0

75.2 89.6

10.43 6.92 0.75 10.04 6.99 0.80 9.71 7.03 0.83

10.82 6.76 0.77 10.42 6.82 0.81 10.08 6.85 0.84

Symbol Notes

DB : Dry Bulb Temperature [°F] 1. All capacities are net, evaporator fan motor heat is deducted.

WB : Wet Bulb Temperature [°F] 2. Indicates nominal capacity.

TC : Total Capacity [kBtu/h] 3. Direct interpolation is permissible. Do not extrapolate

SHC : Sensible Heating Capacity [kBtu/h]

PI : Power Input [kW]

(Comp.+ indoor fan motor + outdoor fan motor)

6RWU0-03A YA Chassis

UYC123ALE31(LP123CD3B)

Temperature

68 77 89.6

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

60.8 71.6

9.89 9.38 0.67 9.69 9.49 0.80 9.23 9.69 0.93

11.55 9.13 0.68 11.30 9.23 0.81 10.77 9.40 0.94

64.4 77.0

66.2 80.6

12.88 8.89 0.69 12.61 8.99 0.82 12.02 9.14 0.96

13.48 8.79 0.70 13.20 8.87 0.83 12.58 9.02 0.97

71.6 86.0

75.2 89.6

14.80 8.49 0.71 14.48 8.56 0.85 13.80 8.68 0.99

15.36 8.32 0.72 15.03 8.38 0.86 14.32 8.49 1.00

Temperature

95 104 109.4

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

8.95 9.78 0.98 8.62 9.94 1.04 8.34 10.03 1.07

60.8 71.6

64.4 77.0

10.45 9.48 0.99 10.06 9.62 1.06 9.73 9.70 1.09

11.66 9.21 1.01 11.22 9.33 1.07 10.86 9.39 1.11

66.2 80.6

71.6 86.0

12.20 9.08 1.03 11.75 9.19 1.09 11.36 9.25 1.13

13.39 8.74 1.04 12.89 8.83 1.10 12.47 8.87 1.14

75.2 89.6

13.89 8.54 1.05 13.38 8.61 1.12 12.94 8.65 1.16

UYC153ALE31(LP153CD3B)

Temperature

68 77 89.6

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

12.25 10.79 0.88 11.99 10.92 1.04 11.42 11.15 1.22

60.8 71.6

64.4 77.0

14.29 10.50 0.89 13.99 10.62 1.06 13.33 10.82 1.24

15.94 10.23 0.91 15.61 10.34 1.08 14.87 10.52 1.26

66.2 80.6

71.6 86.0

16.69 10.11 0.92 16.33 10.21 1.09 15.56 10.38 1.28

18.31 9.77 0.94 17.93 9.85 1.11 17.08 9.99 1.29

75.2 89.6

19.01 9.57 0.95 18.60 9.64 1.13 17.73 9.77 1.31

Temperature

95 104 109.4

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

60.8 71.6

11.08 11.26 1.28 10.67 11.43 1.36 10.32 11.54 1.41

12.93 10.91 1.30 12.45 11.07 1.39 12.04 11.16 1.43

64.4 77.0

66.2 80.6

14.43 10.60 1.32 13.89 10.73 1.41 13.44 10.81 1.45

15.10 10.45 1.35 14.54 10.58 1.43 14.06 10.65 1.48

71.6 86.0

75.2 89.6

16.57 10.05 1.36 15.96 10.16 1.45 15.43 10.21 1.50

17.20 9.82 1.38 16.56 9.91 1.47 16.02 9.96 1.52

Symbol Notes

DB : Dry Bulb Temperature [°F] 1. All capacities are net, evaporator fan motor heat is deducted.

WB : Wet Bulb Temperature [°F] 2. Indicates nominal capacity.

TC : Total Capacity [kBtu/h] 3. Direct interpolation is permissible. Do not extrapolate

SHC : Sensible Heating Capacity [kBtu/h]

PI : Power Input [kW]

(Comp.+ indoor fan motor + outdoor fan motor)

YA Chassis 6RWU0-03A

UYH073ALE21(LP073HD2B)

Temperature

68 77 89.6

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

60.8 71.6

5.92 5.91 0.36 5.80 5.98 0.43 5.52 6.11 0.50

6.91 5.75 0.37 6.76 5.82 0.44 6.44 5.92 0.51

64.4 77.0

66.2 80.6

7.71 5.60 0.37 7.55 5.66 0.44 7.19 5.76 0.52

8.07 5.54 0.38 7.90 5.59 0.45 7.52 5.68 0.52

71.6 86.0

75.2 89.6

8.85 5.35 0.38 8.67 5.40 0.46 8.26 5.47 0.53

9.19 5.24 0.39 8.99 5.28 0.46 8.57 5.35 0.54

Temperature

95 104 109.4

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

5.36 6.16 0.53 5.16 6.26 0.56 4.99 6.32 0.58

60.8 71.6

64.4 77.0

6.25 5.97 0.54 6.02 6.06 0.57 5.82 6.11 0.59

6.98 5.80 0.54 6.72 5.88 0.58 6.50 5.92 0.60

66.2 80.6

71.6 86.0

7.30 5.72 0.55 7.03 5.79 0.59 6.80 5.83 0.61

8.01 5.51 0.56 7.71 5.56 0.60 7.46 5.59 0.62

75.2 89.6

8.31 5.38 0.57 8.00 5.43 0.60 7.74 5.45 0.62

UYH093ALE31(LP093HD3B)

Temperature

68 77 89.6

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

7.71 7.33 0.48 7.54 7.42 0.57 7.19 7.57 0.67

60.8 71.6

64.4 77.0

8.99 7.13 0.49 8.80 7.21 0.58 8.39 7.35 0.68

10.03 6.95 0.50 9.82 7.02 0.59 9.36 7.14 0.69

66.2 80.6

71.6 86.0

10.50 6.87 0.50 10.28 6.94 0.60 9.79 7.05 0.70

11.52 6.64 0.51 11.28 6.69 0.61 10.75 6.79 0.71

75.2 89.6

11.96 6.50 0.52 11.70 6.55 0.61 11.15 6.63 0.72

Temperature

95 104 109.4

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

60.8 71.6

6.97 7.65 0.70 6.71 7.77 0.75 6.49 7.84 0.77

8.14 7.41 0.71 7.83 7.52 0.76 7.58 7.58 0.78

64.4 77.0

66.2 80.6

9.08 7.20 0.72 8.74 7.29 0.77 8.45 7.34 0.79

9.50 7.10 0.74 9.15 7.18 0.78 8.85 7.23 0.81

71.6 86.0

75.2 89.6

10.43 6.83 0.74 10.04 6.90 0.79 9.71 6.94 0.82

10.82 6.67 0.76 10.42 6.73 0.80 10.08 6.76 0.83

Symbol Notes

DB : Dry Bulb Temperature [°F] 1. All capacities are net, evaporator fan motor heat is deducted.

WB : Wet Bulb Temperature [°F] 2. Indicates nominal capacity.

TC : Total Capacity [kBtu/h] 3. Direct interpolation is permissible. Do not extrapolate

SHC : Sensible Heating Capacity [kBtu/h]

PI : Power Input [kW]

(Comp.+ indoor fan motor + outdoor fan motor)

6RWU0-03A YA Chassis

UYH123ALE31(LP123HD3B)

Temperature

68 77 89.6

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

60.8 71.6

9.89 10.04 0.67 9.69 10.17 0.80 9.23 10.38 0.93

11.55 9.78 0.68 11.30 9.89 0.81 10.77 10.07 0.94

64.4 77.0

66.2 80.6

12.88 9.53 0.69 12.61 9.63 0.82 12.02 9.79 0.96

13.48 9.41 0.70 13.20 9.51 0.83 12.58 9.66 0.97

71.6 86.0

75.2 89.6

14.80 9.10 0.71 14.48 9.17 0.85 13.80 9.30 0.99

15.36 8.91 0.72 15.03 8.98 0.86 14.32 9.09 1.00

Temperature

95 104 109.4

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

8.95 10.48 0.98 8.62 10.65 1.04 8.34 10.74 1.07

60.8 71.6

64.4 77.0

10.45 10.16 0.99 10.06 10.30 1.06 9.73 10.39 1.09

11.66 9.87 1.01 11.22 9.99 1.07 10.86 10.06 1.11

66.2 80.6

71.6 86.0

12.20 9.73 1.03 11.75 9.85 1.09 11.36 9.91 1.13

13.39 9.36 1.04 12.89 9.46 1.10 12.47 9.51 1.14

75.2 89.6

13.89 9.14 1.05 13.38 9.23 1.12 12.94 9.27 1.16

UYH153ALE31(LP153HD3B)

Temperature

68 77 89.6

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

12.25 10.79 0.88 11.99 10.92 1.04 11.42 11.15 1.22

60.8 71.6

64.4 77.0

14.29 10.50 0.89 13.99 10.62 1.06 13.33 10.82 1.24

15.94 10.23 0.91 15.61 10.34 1.08 14.87 10.52 1.26

66.2 80.6

71.6 86.0

16.69 10.11 0.92 16.33 10.21 1.09 15.56 10.38 1.28

18.31 9.77 0.94 17.93 9.85 1.11 17.08 9.99 1.29

75.2 89.6

19.01 9.57 0.95 18.60 9.64 1.13 17.73 9.77 1.31

Temperature

95 104 109.4

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

60.8 71.6

11.08 11.26 1.28 10.67 11.43 1.36 10.32 11.54 1.41

12.93 10.91 1.30 12.45 11.07 1.39 12.04 11.16 1.43

64.4 77.0

66.2 80.6

14.43 10.60 1.32 13.89 10.73 1.41 13.44 10.81 1.45

15.10 10.45 1.35 14.54 10.58 1.43 14.06 10.65 1.48

71.6 86.0

75.2 89.6

16.57 10.05 1.36 15.96 10.16 1.45 15.43 10.21 1.50

17.20 9.82 1.38 16.56 9.91 1.47 16.02 9.96 1.52

Symbol Notes

DB : Dry Bulb Temperature [°F] 1. All capacities are net, evaporator fan motor heat is deducted.

WB : Wet Bulb Temperature [°F] 2. Indicates nominal capacity.

TC : Total Capacity [kBtu/h] 3. Direct interpolation is permissible. Do not extrapolate

SHC : Sensible Heating Capacity [kBtu/h]

PI : Power Input [kW]

(Comp.+ indoor fan motor + outdoor fan motor)

YA Chassis 6RWU0-03A

UYC09EALE31(LP096CD3B)

Temperature

68 77 89.6

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

60.8 71.6

7.87 7.52 0.49 7.70 7.61 0.59 7.34 7.77 0.68

9.18 7.32 0.50 8.99 7.40 0.60 8.56 7.54 0.69

64.4 77.0

66.2 80.6

10.24 7.13 0.51 10.03 7.21 0.60 9.55 7.33 0.70

10.72 7.05 0.52 10.49 7.12 0.61 10.00 7.23 0.72

71.6 86.0

75.2 89.6

11.76 6.81 0.53 11.52 6.87 0.62 10.97 6.96 0.73

12.21 6.67 0.53 11.95 6.72 0.63 11.39 6.81 0.74

Temperature

95 104 109.4

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

7.12 7.84 0.72 6.85 7.97 0.77 6.63 8.04 0.79

60.8 71.6

64.4 77.0

8.31 7.60 0.73 8.00 7.71 0.78 7.74 7.78 0.80

9.27 7.39 0.74 8.92 7.48 0.79 8.63 7.53 0.82

66.2 80.6

71.6 86.0

9.70 7.28 0.76 9.34 7.37 0.80 9.03 7.42 0.83

10.65 7.01 0.76 10.25 7.08 0.81 9.91 7.12 0.84

75.2 89.6

11.05 6.85 0.78 10.64 6.91 0.83 10.29 6.94 0.85

UYC12EALE31(LP126CD3B)

Temperature

68 77 89.6

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

9.89 9.87 0.67 9.69 9.99 0.80 9.23 10.20 0.93

60.8 71.6

64.4 77.0

11.55 9.61 0.68 11.30 9.71 0.81 10.77 9.90 0.94

12.88 9.36 0.69 12.61 9.46 0.82 12.02 9.62 0.96

66.2 80.6

71.6 86.0

13.48 9.25 0.70 13.20 9.34 0.83 12.58 9.49 0.97

14.80 8.94 0.71 14.48 9.01 0.85 13.80 9.14 0.99

75.2 89.6

15.36 8.76 0.72 15.03 8.82 0.86 14.32 8.93 1.00

Temperature

95 104 109.4

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

60.8 71.6

8.95 10.30 0.98 8.62 10.46 1.04 8.34 10.56 1.07

10.45 9.98 0.99 10.06 10.12 1.06 9.73 10.21 1.09

64.4 77.0

66.2 80.6

11.66 9.69 1.01 11.22 9.82 1.07 10.86 9.89 1.11

12.20 9.56 1.03 11.75 9.67 1.09 11.36 9.74 1.13

71.6 86.0

75.2 89.6

13.39 9.20 1.04 12.89 9.29 1.10 12.47 9.34 1.14

13.89 8.98 1.05 13.38 9.07 1.12 12.94 9.11 1.16

Symbol Notes

DB : Dry Bulb Temperature [°F] 1. All capacities are net, evaporator fan motor heat is deducted.

WB : Wet Bulb Temperature [°F] 2. Indicates nominal capacity.

TC : Total Capacity [kBtu/h] 3. Direct interpolation is permissible. Do not extrapolate

SHC : Sensible Heating Capacity [kBtu/h]

PI : Power Input [kW]

(Comp.+ indoor fan motor + outdoor fan motor)

6RWU0-03A YA Chassis

UYH09EALE31(LP096HD3B)

Temperature

68 77 89.6

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

60.8 71.6

7.87 7.52 0.49 7.70 7.61 0.59 7.34 7.77 0.68

9.18 7.32 0.50 8.99 7.40 0.60 8.56 7.54 0.69

64.4 77.0

66.2 80.6

10.24 7.13 0.51 10.03 7.21 0.60 9.55 7.33 0.70

10.72 7.05 0.52 10.49 7.12 0.61 10.00 7.23 0.72

71.6 86.0

75.2 89.6

11.76 6.81 0.53 11.52 6.87 0.62 10.97 6.96 0.73

12.21 6.67 0.53 11.95 6.72 0.63 11.39 6.81 0.74

Temperature

95 104 109.4

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

7.12 7.84 0.72 6.85 7.97 0.77 6.63 8.04 0.79

60.8 71.6

64.4 77.0

8.31 7.60 0.73 8.00 7.71 0.78 7.74 7.78 0.80

9.27 7.39 0.74 8.92 7.48 0.79 8.63 7.53 0.82

66.2 80.6

71.6 86.0

9.70 7.28 0.76 9.34 7.37 0.80 9.03 7.42 0.83

10.65 7.01 0.76 10.25 7.08 0.81 9.91 7.12 0.84

75.2 89.6

11.05 6.85 0.78 10.64 6.91 0.83 10.29 6.94 0.85

UYH12EALE31(LP126HD3B)

Temperature

68 77 89.6

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

9.89 9.87 0.67 9.69 9.99 0.80 9.23 10.20 0.93

60.8 71.6

64.4 77.0

11.55 9.61 0.68 11.30 9.71 0.81 10.77 9.90 0.94

12.88 9.36 0.69 12.61 9.46 0.82 12.02 9.62 0.96

66.2 80.6

71.6 86.0

13.48 9.25 0.70 13.20 9.34 0.83 12.58 9.49 0.97

14.80 8.94 0.71 14.48 9.01 0.85 13.80 9.14 0.99

75.2 89.6

15.36 8.76 0.72 15.03 8.82 0.86 14.32 8.93 1.00

Temperature

95 104 109.4

WB°F DB°F TC SHC PI TC SHC PI TC SHC PI

57.2 68.0

60.8 71.6

8.95 10.30 0.98 8.62 10.46 1.04 8.34 10.56 1.07

10.45 9.98 0.99 10.06 10.12 1.06 9.73 10.21 1.09

64.4 77.0

66.2 80.6

11.66 9.69 1.01 11.22 9.82 1.07 10.86 9.89 1.11

12.20 9.56 1.03 11.75 9.67 1.09 11.36 9.74 1.13

71.6 86.0

75.2 89.6

13.39 9.20 1.04 12.89 9.29 1.10 12.47 9.34 1.14

13.89 8.98 1.05 13.38 9.07 1.12 12.94 9.11 1.16

Symbol Notes

DB : Dry Bulb Temperature [°F] 1. All capacities are net, evaporator fan motor heat is deducted.

WB : Wet Bulb Temperature [°F] 2. Indicates nominal capacity.

TC : Total Capacity [kBtu/h] 3. Direct interpolation is permissible. Do not extrapolate

SHC : Sensible Heating Capacity [kBtu/h]

PI : Power Input [kW]

(Comp.+ indoor fan motor + outdoor fan motor)

YA Chassis 6RWU0-03A

Heating Capacity

UYH073ALE21(LP073HD2B)

Indoor Air

Temperature 32

Outdoor Air Temperature : DB°F

42.8

50 59

DB°F TC PI TC PI TC PI TC PI

60.8 5.89 0.45 6.85 0.49 7.42 0.51 8.19 0.55

64.4 5.71 0.47 6.64 0.50 7.18 0.53 7.93 0.57

68.0 5.54 0.48 6.40 0.52 6.97 0.55 7.69 0.59

71.6 5.34 0.50 6.21 0.54 6.72 0.57 7.41 0.61

75.2 5.15 0.51 5.99 0.55 6.49 0.58 7.16 0.62

UYH093ALE31(LP093HD3B)

Indoor Air

Temperature 32

Outdoor Air Temperature : DB°F

42.8

50 59

DB°F TC PI TC PI TC PI TC PI

60.8 7.55 0.58 8.78 0.63 9.50 0.66 10.49 0.71

64.4 7.31 0.60 8.50 0.65 9.20 0.68 10.16 0.73

68.0 7.09 0.62 8.20 0.67 8.93 0.71 9.86 0.76

71.6 6.84 0.64 7.95 0.69 8.61 0.73 9.50 0.78

75.2 6.60 0.66 7.68 0.71 8.31 0.75 9.17 0.80

UYH123ALE31(LP123HD3B)

Indoor Air

Temperature 32

Outdoor Air Temperature : DB°F

42.8

50 59

DB°F TC PI TC PI TC PI TC PI

60.8 9.94 0.79 11.56 0.85 12.52 0.89 13.82 0.96

64.4 9.63 0.81 11.20 0.88 12.12 0.92 13.38 0.99

68.0 9.34 0.84 10.80 0.91 11.76 0.95 12.98 1.02

71.6 9.01 0.87 10.47 0.93 11.34 0.98 12.51 1.05

75.2 8.70 0.89 10.11 0.96 10.95 1.01 12.08 1.09

Symbol Notes

DB : Dry Bulb Temperature [°F] 1. All capacities are net, evaporator fan motor heat is deducted.

Indicates nominal capacity.

WB : Wet Bulb Temperature [°F] 2.

TC : Total Capacity [kBtu/h]

PI : Power Input [kW]

(Comp.+ indoor fan motor + outdoor fan motor)

6RWU0-03A YA Chassis

UYH153ALE31(LP153HD3B)

Indoor Air

Temperature 32

Outdoor Air Temperature : DB°F

42.8

50 59

DB°F TC PI TC PI TC PI TC PI

60.8 12.34 1.10 14.35 1.19 15.53 1.25 17.14 1.34

64.4 11.95 1.14 13.89 1.23 15.04 1.29 16.60 1.38

68.0 11.59 1.17 13.40 1.27 14.59 1.33 16.10 1.43

71.6 11.17 1.21 12.99 1.31 14.06 1.38 15.52 1.47

75.2 10.79 1.25 12.55 1.35 13.58 1.42 14.99 1.52

UYH09EALE31(LP096HD3B)

Indoor Air

Temperature 32

Outdoor Air Temperature : DB°F

42.8

50 59

DB°F TC PI TC PI TC PI TC PI

60.8 7.83 0.60 9.10 0.65 9.85 0.68 10.87 0.73

64.4 7.58 0.62 8.81 0.67 9.54 0.70 10.53 0.75

68.0 7.35 0.64 8.50 0.69 9.26 0.73 10.22 0.78

71.6 7.09 0.66 8.24 0.71 8.92 0.75 9.85 0.80

75.2 6.84 0.68 7.96 0.73 8.61 0.77 9.51 0.83

UYH12EALE31(LP126HD3B)

Indoor Air

Temperature 32

Outdoor Air Temperature : DB°F

42.8

50 59

DB°F TC PI TC PI TC PI TC PI

60.8 10.13 0.78 11.78 0.84 12.75 0.88 14.07 0.95

64.4 9.81 0.80 11.40 0.87 12.35 0.91 13.63 0.98

68.0 9.52 0.83 11.00 0.90 11.98 0.94 13.22 1.01

71.6 9.17 0.86 10.67 0.92 11.55 0.97 12.74 1.04

75.2 8.86 0.88 10.30 0.95 11.15 1.00 12.31 1.07

Symbol Notes

DB : Dry Bulb Temperature [°F] 1. All capacities are net, evaporator fan motor heat is deducted.

Indicates nominal capacity.

WB : Wet Bulb Temperature [°F] 2.

TC : Total Capacity [kBtu/h]

PI : Power Input [kW]

(Comp.+ indoor fan motor + outdoor fan motor)

YA Chassis

1.8 Electrical characteristics

6RWU0-03A

Model

UYC073ALE21(LP073CD2B)

UYC093ALE31(LP093CD3B)

UYC123ALE31(LP123CD3B)

UYC153ALE31(LP153CD3B)

UYH073ALE21(LP073HD2B)

UYH093ALE31(LP093HD3B)

UYH123ALE31(LP123HD3B)

UYH153ALE31(LP153HD3B)

UYC09EALE31(LP096CD3B)

UYC12EALE31(LP126CD3B)

UYH09EALE31(LP096HD3B)

UYH12EALE31(LP126HD3B)

Unit

Hz

60

Voltage Voltage range MCA

14.9

Power

MOP

15.0

208~230

Min : 187

Max : 253

19.5

19.5

19.5

14.9

19.5

20.0

20.0

20.0

15.0

20.0

265

Min : 239

Max : 292

19.5

19.5

17.9

17.9

17.9

17.9

20.0

20.0

15.0

15.0

15.0

15.0

Notes :

1. Voltage range Voltage supplied to the unit terminals should be within the minimum and maximum range.

2. Maximum allowable voltage unbalance between phase is 2 %.

3. Select wire spec. based on the larger value of MCA.

4. LRA & RLA is measured during each individual compressor test condition.

5. IFM & OFM is measured at unit test condition.

6. Recommended circuit breaker is ELCB (Earth Leakage circuit breaker)

5.0

6.55

3.3

4.4

3.3

4.4

Compressor

RLA

2.9

LRA

16.0

3.7

5.0

6.55

2.9

4.0

19.0

27.0

38.6

16.0

19.0

26.0

38.6

20.0

22.0

20.0

22.0

MCA : Minimum Circuit Amperes (A)

0.36

0.36

0.36

0.36

0.36

0.36

Motor FLA

IFM

0.36

OFM

0.36

0.36

0.36

0.36

0.36

0.36

0.36

0.36

0.36

0.36

0.36

0.36

0.36

0.36

0.36

0.36

0.36

MOP : Maximum rating over current protective device (A)

LRA : LRA Locked Rotor Ampere (A)

RLA : Rated Load Amperes (A)

OFM : Outdoor Fan Motor (W)

IFM : Indoor Fan Motor (W)

FLA : Full Load Amperes (A)

6RWU0-03A

1.9 Operation range

Cooling

46

(115°F)

Continuous operation

21

(70°F)

12

(54°F)

Operative

12(54°F) 30(86°F)

Indoor Unit [℃ (℉) DB]

YA Chassis

Heating

24

(75°F)

Continuous operation

1

(34°F)

Electric Heater

-20

(-4°F)

12(54°F) 30(86°F)

Indoor Unit [℃ (℉) DB]

Control Device

2. Control Device

2.1 Electronic Controls

6RWU0-03A

The Electronic controls and the panel display is as shown below.

FAN SPEED

• Every time you push this button, it cycles through the settings as follows:

{High(F2)

Low(F1)

High(F2)

Low(F1)}

* For Cooling only models(for some specific regions), the “HEAT” option is not there in the

panel display(escutcheon).

POWER

• To turn the air conditioner ON, push this button.

To turn the air conditioner OFF, push the button again.

• This button takes priority over any other button.

MODE

-

Push this button to cycle through the modes from COOL

FAN

HEAT

COOL.

- COOL

• Fan runs continually for normal cooling operation.

- ENERGY SAVER

• The fan stops when the compressor stops cooling.

Approximately every 3 minutes the fan will turn on and the unit will check the room air temperature to determine if cooling is needed.

- FAN

• Fan operation without heating or cooling.

- HEAT

• Fan runs continually for normal heating operation.

TEMPERATURE SETTING

• Use this button to automatically control the temperature of the room.

The temperature can be set within a range of

54°F to 86°F by increments of 1°F.

• The setting appears in the display.

TIMER

- SHUT-OFF TIME

• You will usually use shut-off time while you sleep.

• If unit is running, use Timer to set number of hours until shut-off.

• For your sleeping comfort, once Time is set, the Temperature setting will raise 2°F after 30 minutes, and once again after another 30 minutes.

• Push Timer to cycle through the settings from 1 Hour

2 Hours

...

12 Hours maximum.

6RWU0-03A Control Device

Additional Controls

Additional controls can be seen after removing the front grille and the option cover of the control box.

To remove the front grille, pull out the bottom at both the sides and then lift up the grille as shown in the figure on the right.

And to install the front grille back to itʼs original position, place the tabs over the top of the unit and push the bottom of the front grille until the clips snap into place.

Now the additional controls are located behind the option cover of the control box. The standard settings are in the "OFF" position as shown in the figure below. The authorized personnel has to check the switches and ensure that the switches are in the desired position.

ON

REMOTE ON ON ON ON

OFF

OFF

6

OFF

7

Remote/Local

Energy Saver

Temperature Limit 1

Temperature Limit 2

Temperature Limit 3

PTAC/PTHP

UNIT TYPE

Here in the figure above the three Temperature limit switches ( Temperature Limit 1, Temperature Limit 2 and Temperature

Limit 3) can provide various temperature ranges of operation by means of different combinations of dip switches as shown in the Table below. These temperature limits prevent overcooling and over heating, by limiting the lowest temperature for cooling and by limiting the highest temperature for heating respectively, thereby reducing energy costs.

Temperature Temperature Temperature

Limit #1 Limit #2 Limit #3

OFF OFF OFF

Cooling Operation

Lowest Temp.

54°F (12.2°C)

Highest Temp.

86°F (30.0°C)

ON OFF OFF 56°F (13.3°C) 86°F (30.0°C)

OFF

ON

OFF

ON

OFF

ON

ON

ON

OFF

OFF

ON

ON

OFF

OFF

ON

ON

ON

ON

58°F (14.4°C)

60°F (15.5°C)

62°F (16.6°C)

64°F (17.7°C)

66°F (18.9°C)

68°F (20.0°C)

86°F (30.0°C)

86°F (30.0°C)

86°F (30.0°C)

86°F (30.0°C)

86°F (30.0°C)

86°F (30.0°C)

#6

OFF

OFF

ON

ON

#7

OFF

ON

OFF

ON

Heating Operation

Lowest Temp.

54°F (12.2°C)

Highest Temp.

86°F (30.0°C)

84°F (28.9°C) 54°F (12.2°C)

54°F (12.2°C)

54°F (12.2°C)

54°F (12.2°C)

54°F (12.2°C)

54°F (12.2°C)

54°F (12.2°C)

82°F (27.8°C)

80°F (26.7°C)

78°F (25.5°C)

76°F (24.4°C)

74°F (23.3°C)

72°F (22.2°C)

Unit Type

Cooling+Electric Heater+Heat Pump

Cooling+Electric Heater

Heat Pump Only

Cooling Only

Note:

This Temperature limit option is not available with the Remote Wall Thermostat.

Control Device 6RWU0-03A

• Remote/Local Control

When remote/local switch #1 is on, it allow the unit to operate by the Remote Wall Thermostat.

The unit control by knobs are not available.

• Energy Saver

The energy saver switch #2 is on. This switch is set at cycle fan to provide continuous fan operation in cool or heat modes. When the switch is off the continuous fan allows continuous circulation of room air and make the more balanced temperature of the room. When the switch is on, the fan is on or off with the compressor or with the heater.

• Front Desk Control

When the pair wire is connected to the connector FD2 and FD1, the unit can be turned ON or OFF with a switch located at the Front Desk Control panel. When the front desk switch is ON, the fan operates according to the setting without working compressor and heater. When the front desk switch is OFF, the unit can operate according to the setting of controls.

Wire # AWG

#22

#20

#18

#16

Motion Sensor

Motion Sensor

Door Switch

Door Switch

Front Desk Control

Front Desk Control

Maximum Length

600 ft (180 m)

900 ft (270 m)

1500 ft (450 m)

2000 ft (610 m)

FD2 FD1 DR2 DR1 MS2 MS1

(Molex Housing Spec 396-06V)

Note : The following figures show wiring schematics for heat pump and straight cool units with electric heat, respectively.

Wiring Schematic for Remote Heat Pump Wiring Schematic for Straight Cool Unit.

6RWU0-03A Control Device

Remote Wall Thermostat

When the wires are connected, the unit will be controlled by a remote wall thermostat.

The thermostat connections supply the 24 Volt AC. When you install the digital/electronic thermostat, you must set it to 24

Volt AC. See the installation instruction in this manual for the Remote Wall Thermostat.

24 Volt-N

24 Volt-L

Compressor

Heater

Reversing Valve

High Fan

Low Fan

GL GH O W Y R C

(Molex Housing Spec 396-07V)

FUNCTION:

If the unit has a malfunction, a green OPERATION LED located on the Display PCB used by the unit to indicate the errors.

USE:

If the customer has to register a complaint to the service center, he can be very clear about registering the complaint that what is happening & by referring the user's manual the customer can clearly define the problem.

So that the engineer should go fully prepared with the prescribed tools to be used regarding that problem. It also keeps the customer aware about the unit.

Here are some of the problems defined below for which the LED indicates by flashing.

The errors are the mentioned which is as follows:

Control Device 6RWU0-03A

• Electrical Controls

Fault

Codes

CH 01

CH 02

Description of

Inspection

Cause of Error Check Point

Indoor Air

Thermistor Error

Indoor air temperature sensor fault is occurred by indoor air temperature ≤ -35℃ or the indoor air temperature ≥ 100°C

• Check the error after change sensor.

• Check the insertion of PCB Connector

Wafer.

Indoor Coil

Thermistor Error

Indoor pipe temperature sensor fault is occurred by indoor pipe temperature ≤ -35℃ or the indoor pipe temperature ≥ 100°C

• Check the error after change sensor.

• Check the insertion of PCB Connector

Wafer.

CH 07

Themostat

Wiring Error

During operating Remote mode, if PTAC receives control commands that can not be drive from

Themostat, Themostat error occurred.

• Check the connection with Themostat comparing with manual.

CH 09

EEPROM Check

Sum Error

EEPROM Check Sum Error is occurred by unmatching between the original checksum and the calculated checksum.

Check the insertion of EEPROM.

Unplug and plug the power code

CH 10

CH 34

CH 44

Indoor Fan Error

High Pressure

Switch Error

Indoor fan lock error is occurred by no feedback signal from Hall sensor located

BLDC Motor in 50 seconds delay time or feedback signal lower than 50RPM. (Applied in model using BLDC Motor)

If opening high pressure switch for 65 miliseconds is generated more than 10 times in 1 hour, High Pressure Switch Error occurred.

Outdoor Air

Thermistor Error

(PTHP Only)

Outdoor air temperature sensor fault is occurred by outdoor air temperature ≤ -35℃ or the indoor air temperature ≥ 100°C

• Check the insertion of BLDC Connector.

• Check whether the output voltage between the two terminals 4-5pins in CN-MOTOR-ODF is 15V.

• Check whether the output voltage between the two terminals 4-6pins is over 2V.

• Check whether the output voltage between the two terminals 4-7pins is exist or not.

• Check the existence of short key between

CN-PRESS.

• Check the insertion of PCB Connector

Wafer.

Check the error after change sensor.

Check the insertion of PCB Connector

Wafer.

CH 45

CH 67

Outdoor Coil

Thermistor Error

(PTHP Only)

Outdoor pipe temperature sensor fault is occurred by outdoor pipe temperature ≤ -35℃ or the outdoor pipe temperature ≥ 100°C

Check the error after change sensor.

Check the insertion of PCB Connector

Wafer.

Outdoor Fan

Error

Outdoor fan lock error is occurred by no feedback signal from Hall sensor located

BLDC Motor in 50 seconds delay time or feedback signal lower than 50RPM. (Applied in model using BLDC Motor)

Check the insertion of BLDC Connector.

Check whether the output voltage between the two terminals 4-5pins in CN-MOTOR-ODF is 15V.

Check whether the output voltage between the two terminals 4-6pins is over 2V.

Check whether the output voltage between the two terminals 4-7pins is exist or not.

Note:

• Overheating Protection

This feature prevents melting of unit by electrical heater located inside of the unit at the remote mode (when the unit is connected with wall thermostat). LED on the control panel displays "OP"

• Freeze Protection

This feature prevents freezing of room at low temperature. LED on the control panel displays "FP"

Part 3 Design and Installation

1 General installation procedure ..........................................................51

2 Installation of unit ...............................................................................52

2.1 Safety precautions ............................................................................................52

2.2 Points for explanation about operations ...........................................................55

2.3 Selecting installation site for the unit ................................................................55

2.4 Installation of Unit .............................................................................................56

2.5 Wall sleeve installation .....................................................................................58

Design and installation PTAC 50

General Installation Procedure

1. General Installation Procedure

6RWU0-03A

Installation Procedure Remarks

Determination of work scope

……

Check and confirm required load calculation, model selection etc…

Selection of suitable location for unit

……

The base or the foundation of the Air-Conditioner should be firm and vibration proof and air-flow should not be restricted on either side of the unit - front and the back.

Installation of Wall sleeve

……

Check out the Wall opening to make sure the Wall sleeve fits properly.

Installation of indoor unit

……

Check the size of the selected model and make sure the fitting is made correctly.

Drain pipe work

Insulation works

Fit Outer Grille

……

Make sure the drain pipe is big enough and adjust it to a downward gradient.

……

The Air-Conditioner supporting parts should secure firmly to the wood, masonry and metal.

……

The Air Conditioner should be protected from physical contact with animals or any external object.

Transfer charge to customer

……

Educate the customer or the operator on how to operate the Air-Conditioner and the utility of the manuals.

51 PTAC General installation guideline

6RWU0-03A

2. Installation of unit

2.1 Safety precautions

Installation of unit

To prevent injury to the user or other people and property damage, the following instructions must be followed.

n

Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness is classified by the following indications.

n

Because of the weight of the product, it is recommended that you have a helper to assist in the installation.

WARNING

This symbol indicates the possibility of death or serious injury.

CAUTION

This symbol indicates the possibility of injury or damage to properties only.

n

Meanings of symbols used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

WARNING

Do not use a damaged power cord, plug or loose socket.

• Otherwise there is risk of fire or electric shock.

Always plug onto a grounded outlet.

• Otherwise there is risk of fire or electric shock.

Do not extend or modify the power cord length.

• Otherwise there is risk of fire or electric shock due to heat generation.

Do not install, remove or reinstall the unit by yourself.

• Otherwise there is risk of fire, electric shock, explosion or injury.

Be cautious when unpacking and installing the product.

• Sharp edges could cause injury. Especially be careful of the case edges and the fins on the condenser and evaporator.

Do not store or use flammable gas or combustibles near the Air-Conditioner.

• Otherwise there is risk of fire, explosion or failure of product.

Be sure the installation area does not deteriorate with time.

• If the base collapses then the Air- Conditioner might fall causing property damage, product failure and personal injury.

Do not place heavy object on the power cord and take care that the cord is not pressed.

• Otherwise there is a danger of fire or electric shock.

Do not share the outlet with other appliances.

• Otherwise there is a risk of fire or electric shock due to heat generation.

While unplugging, hold the head of the plug and do not touch it with wet hands.

• Otherwise there is a risk of fire or electric shock.

Do not place the power cord near a heater.

• Otherwise there is a risk of fire or electric shock.

Do not allow water to run into electric parts.

• Otherwise there is a risk of electric shock or failure of the unit.

Use a soft cloth to clean. Do not use wax, thinner or a strong detergent.

• Otherwise the appearance of the Air-Conditioner may deteriorate, change color or develop flaws on the surface.

Unplug the unit if any strange sound, odor or smoke comes out of it.

• Otherwise there is a risk of fire or electric shock.

Installation PTAC 52

Installation of unit 6RWU0-03A

Do not open the inlet grille of the product during operation.

• Otherwise it may cause electric shock and failure.

If water enters the product, turn off the power switch, remove the power plug from the socket and contact the service center immediately.

• Otherwise it may cause electric shock and failure of the product.

Ensure proper ventilation in the room when using this appliance together with a stove.

• Otherwise there may be a shortage of oxygen.

Before cleaning the unit turn off the power to the unit.

• The fan blows at a high speed and may cause injury. Also the appliance may cause electric shock.

Turn off the main power switch when the unit is not used for a long time.

• We can prevent accidental startup and thereby prevent injury.

Do not operate or stop the unit by inserting or pulling out the power plug.

• Otherwise it may cause electric shock or fire due to heat generation.

Do not use a damaged power cord and do not use an unspecified power cord.

• Otherwise it may cause electric shock or fire.

Do not operate the unit with wet hands or in a damp environment.

• Otherwise it may cause electric shock or fire.

Always hold the plug by the head while plugging or unplugging it onto the socket.

• Otherwise it may cause electric shock or it may damage the power cord.

When there is a gas leakage, open the windows for ventilation before operating the unit.

• There is a risk of fire or explosion.

Take care not to touch the metal parts of the Air-Conditioner while removing the filter.

• Presence of sharp metal parts may cause injury.

During installation and un installation always contact the dealer of an Authorized service center.

• Otherwise there is a risk of fire, electric shock, explosion or injury.

Be sure only to use those parts which are listed in the service parts list. Never attempt to modify the equipment.

• Use of parts not listed in the service list can cause an electrical shock, excessive heat generation or fire.

Safely dispose off the packing materials.

• Things like screws, nails, batteries, etc….can cause injury to a person. Take care to throw away the plastic packaging bags so that children may not play with them.

Do not touch, operate or repair the product with wet hands.

• Otherwise there is a risk of electric shock or fire.

Do not allow water to run into electric parts. Install the unit away from water sources.

• Otherwise there is a risk of fire, electric shock or failure of the product.

If any strange sound, smell or smoke comes out of the product, immediately disconnect the power supply and contact the nearest service center.

• Otherwise there is a risk of fire, electric shock or failure of the product.

Do not use the socket if it is loose or damaged.

• Otherwise it may cause shock or electric fire.

Keep fire arms away from the unit.

• Otherwise it may cause fire.

Do not use the power cord close to heating tools.

• Otherwise it may cause an electric shock or fire.

Do not disassemble or modify the products randomly.

• Otherwise it may cause an electric shock or failure of the product.

53 PTAC Installation

6RWU0-03A Installation of unit

CAUTION

Install the product in such a way that the noise or hot wind from the outdoor unit may not cause any disturbance to neighbors.

• Otherwise there may be disputes with neighbors.

During installation the unit should be horizontally leveled.

• Otherwise it may cause vibration or water leakage.

Do not allow direct exposure of pet animals and house plants to air flow from the unit.

• Otherwise it may cause injury to them.

Do not block the flow of air into the inlet and the outlet.

• Otherwise it may lead to failure of the product.

Use a soft cloth to clean. Do not use wax, thinner or a strong detergent.

• Otherwise the appearance of the air conditioner may deteriorate, change color and develop flaws on the surface.

Do not step on the unit and do not place anything above it.

• Otherwise the unit may fall and cause personal injury.

Always place the filter securely and clean it every two weeks.

• Operation without filters may cause the unit to fail.

Do not drink water drained by the air-conditioner.

• The drained water contains contaminants and can make you sick.

Be cautious so as not to touch the sharp edges during installation.

• Otherwise it may cause injury.

Avoid excessive cooling and ventilate the room at times.

• Otherwise it may cause personal injury.

Do not try to lift the unit alone.

• Avoid personal injury.

Do not install the product where it is exposed to sea wind (salt spray) directly.

• Otherwise it may corrode the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.

Install the drain hose so as to ensure that the water is drained properly.

• Otherwise there might be water leakage.

Replace all the batteries in the remote control with new ones of the same type.

Do not mix old and new batteries or different type of batteries.

• Otherwise there is a risk of fire or explosion.

If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote controller if the batteries have leaked.

• Otherwise the chemicals in the batteries may cause burns or other health hazards.

Do not use the product for purposes such as preserving foods, works of art, etc…It is a consumer air conditioner not a precision refrigeration system.

• Otherwise there is risk of damage or loss to property.

Do not recharge or disassemble the batteries. Do not dispose off batteries in fire.

• Otherwise the batteries may burn or explode.

Do not clean the air conditioner using water.

• Water may enter the unit and degrade the insulation. Hence, it may cause an electric shock.

Ventilate well when used near a stove.

• Otherwise there may be a lack of Oxygen in the room.

Do not put pets or house plants where it is exposed to direct air-flow.

• It is injurious to the health of the pet and the plant.

Installation PTAC 54

Installation of unit 6RWU0-03A

2.2 Points for explanation about operations

The items listed under the WARNING and CAUTION list in the operation manual are the items pertaining to possibilities for bodily injury and material damage in addition to the general usage of the product. Accordingly, it is necessary that you make a full explanation about the described contents and also ask your customers to read the owners manual.

NOTE to the installer

Be sure to instruct customers how to properly operate the unit (especially cleaning filters, operating different functions and adjusting the temperature) by having them carry out operations themselves while looking at the manual.

• Be sure to read this manual before installing the indoor unit.

• Entrust the duty of installation to the place of purchase or an authorized serviceman. Improper installation could lead to damage of the product, bodily injury , electric shock or fire.

• Use parts only provided along with the unit or parts satisfying required specifications.

Unspecified parts could cause the unit to fall out of place, or could lead to leaks and in the worst cases, electric shock or fire.

2.3 Selecting installation site for the unit

Select an installation site where the following conditions are fulfilled and that meet your customers approval.

1) Location should be strong enough to bear the weight of the unit.

2) Location should be accessible to inspection and service in future.

3) Location should allow suitable gradient for the drainage of water.

4) Location free from electrical noise.

5) Location allowing optimum air distribution without restricting air flow.

6) Location having no risk of flammable gas leakage.

7) Location free from any machinery emitting electromagnetic waves which may disturb the control system thus causing the unit to malfunction.

8) Location should be free from flammable gases, carbon fiber or ignitable dust suspensions in the air or in areas where volatile flames like gasoline and thinner are handled. Operating the unit in such conditions may lead to fire.

9) Finally conform to local rules and regulations for air conditioner installation.

55 PTAC Installation

6RWU0-03A

2.4 Installation of unit

The PTAC and its components are as shown below.

Installation of unit

1. WALL SLEEVE

2. FRONT GRILLE

3. AIR FILTER

4. AIR INTAKE

5. AIR DISCHARGE

6. VERTICAL AIR DEFLECTOR

(HORIZONTAL LOUVER)

7. EVAPORATOR

8. CONTROL PANEL

9. POWER CORD

10. COMPRESSOR

Use the correct wall sleeve and outdoor grille

This unit is designed to be installed in the insulated wall sleeve.

When you place the unit into the existing sleeve, the wall sleeve used to mount the new unit must be in good structural condition and have the outdoor grille that securely attaches to the sleeve or the flange of the sleeve to secure the new air conditioner.

With the LG sleeve, you can maintain the best performance of the new air conditioner.

If you keep the existing sleeve, you run the risk of poor performance or product failure. This is not covered under the LG warranty.

Remove the vertical deflectors in the existing grille to reduce condenser air recirculation that can cause the unit to poor cooling or heating and component failure.

Unit

11. BASE PAN

12. BRACE

13. CONDENSER

14. OUTDOOR GRILLE (ARCHITEC-

TURAL GRILLE)

Wall Sleeve

Outdoor Grille

Front Grille

(Shipped with the unit)

Installation PTAC 56

Installation of unit 6RWU0-03A

CAUTION

• There are sharp edges that can cause serious cuts.

• When lifting the air conditioner.

Use 2 people to lift.(the unit is heavy)

1,066 mm

(42")

For existing sleeve, you should measure the wall sleeve dimensions.

Install the new air conditioner according to these installation instructions to achieve the best performence. The wall sleeve used to mount the new air conditioner must be in good structural condition and have a rear grille that securely attaches to the sleeve or the flange of the sleeve to secure the new air conditioner.

349 mm

(13 3 /

4

")

537mm(21")

406 mm

(16")

• To avoid vibration and noise, make sure the unit is installed securely and firmly.

42"

1/2" SQ. HOLE (2 REQ'D.)

13-3/4"

2-3/4"

When installing the sleeve & Front grille, make certain there is nothing within 20" Back & front of sleeve & front grille, that would interfere with heat radiation and exhaust air flow.

16"

1-1/2" TYP 1/2"

5-5/8"

4"

6"

21"

1/2" DIA.

HOLE (3 REQ'D.)

Wall opening 16-1/4"x42-1/4"

Recommended

To maintain the best performance of LG PTAC

1. An insulation strip must be attached. The insulation strip is provided with the box.

2. After assembly of sleeve & Front grille, the gap should be 20" from both sleeve & grille. For assembly PTAC Model refer the digram given below.

GRILLE

36"

13-3/4"

TOP VIEW

INSULATION

COOLED

AIR

WALL

SLEEVE

HEAT

RADIATION

42"

ROOM

CABINET

1) Take out the insulation strip from the upper packing.

INTAKE

AIR

1/4" Bubble of the level

Over 20"

WALL

Over 20"

2) Attach the insulation strip onto the rear upper side of the wall sleeve.

3) Insulation strip prevents the exhaust air from re-entering from either side of condenser space which may decrease the cooling efficiency of condenser.

280 mm

(11")

Front

Sleeve

Insulation Strip

Rear

6RWU0-03A Installation of unit

2.5 WALL SLEEVE INSTALLATION

Wall Case Installation Data

General

Generally, units are installed 3" to 5" above the floor

(flush to finished floor installation is possible) as near to the center of the room as possible; underneath a window or a glass panel is typical. Normal installation of the wall case allows installation flexibility; from flush with the finished interior wall to a minimum of 1/4" of the wall case extending beyond the finished exterior of the building.

Special consideration must be given to installations where the wall case does not extend a minimum of 1/4" beyond the finished exterior wall.

framing, moving electrical outlets, and other expensive modifications.

For existing construction it is important that carpentry, masonry and electrical work be performed by competent, qualified personnel. Since installations in existing construction may involve removal of building material from the structure, location of the wall case must be precisely done.

13-3/4"

42"

1/2" SQ. HOLE (2 REQ'D.)

Regardless of the installation, there are several things to consider when selecting a location for installing the unit. For instance, drapery location could interfere with air discharge, and placement of furniture may have an impact on the performance of the unit. The following information is intended to minimize installation problems and assure you of a trouble-free installation.

16"

1-1/2" TYP 1/2"

2-3/4"

6"

36"

21"

1/2" DIA.

HOLE (3 REQ'D.)

Wall opening 16-1/4"x42-1/4"

4"

Refer to last page for required wall opening dimensions. Minimum recommended interior and exterior case projection for standard wall thicknesses are shown in the drawings in this manual. The case may be installed flush with the finished indoor wall.

Mounting an outdoor grille or louver section to the building face may cause a space between the outdoor coil and the louver section. Air splitters, aligned with the ends of the outdoor coil, must be installed between the outdoor coil inlet and outlet air streams. Gaps between the outdoor coil and the louver section may allow condenser air recirculation and affect the operation of the unit.

The wall case should be level from side to side and from level to 1/4 bubble tilt to the outdoors.

The condensate disposal system in the unit is designed to dissipate the condensate water generated during cooling operation in accordance with ARI standards and actually uses this water for maximum unit efficiency. A level unit will also insure proper performance of the Internal

Condensate Removal (ICR) system optional on heat pump units.

For new construction, early planning with the architect is necessary. Unit location, electrical connection locations, and wall openings of proper dimension are essential to avoid the necessity of rework, fillers,

Installation PTAC 58

1

1

1

Installation of unit 6RWU0-03A

Preparation of the front grille

Carefully remove shipping tape from the front grille.

The outside edge of the wall case should extend at least

1/4" beyond the outside wall.

This is necessary for proper caulking, to prevent sealing thedrain holes in the rear flange of the wall case, and to facilitate the installation of an accessory drain, if used.

Shipping Tape

The wall case should be level from side to side and from level to 1/4 bubble tilt to the outdoors. The condensate disposal system in the unit is designed to dissipate the condensate water generated during cooling operation in accordance with ARI standards and actually uses this water for maximum unit efficiency. A level unit will also insure proper performance of the Internal Condensate Removal

(ICR) system optional on heat pump units.

Brick, Frame, Stucco and Shingle

Construction

For new construction, the opening for the wall case should be framed and inserted into the opening during construction. Lintels should be used when the building material is heavy and is not self supporting (such as brick). The wall case will fit an opening of six courses of standard brick or five courses of jumbo brick. Wall framing in this type construction is normally on 16" centers and the wall case will fit a framed opening spanning three 16" O.C. 2" x 4" stud spaces.

For existing construction the indoor and outdoor wall will need to be cut out, allowing for clearances of 1/8" on all sides of the wall case. Work should begin on the inside wall.

Cut the correct dimensions and mark (using drill holes) the outside wall from each corner of the inside cutout. Studding that interferes with the opening must be removed and a suitable frame constructed to secure the wall case and provide adequate support for case and chassis.

Preparation of the Wall Case for All Types of

Construction

As shipped, the LG wall sleeve is ready for installation.

Do not remove the stiffener from inside the wall case or the weather closure panel from the outside face of the wall case until the outdoor grille and chassis are ready to be installed.

Installation of Wall Case in Wall Opening

1. Position the wall case into the wall. The room side edge of the wall case should be at least flush with the finished wall for line cord installations and permanent connection installations when no sub-base is used, and should project into the room at least 2-3/8" when a sub-base is used. If the minimum exterior dimensions are not met, refer to page 60.

2. The wall case should be secured to the wall at both sides.

Use a minimum of two screws or other fastening device on each side. See Figure 2 page 60. Mark the wall case on each side 2" from the bottom and 2" from the top at a point where basic wall structure is located. Drill wall case and use fasteners appropriate for wall construction. All holes for fasteners in the side of the wall case must be at least 2" up from the bottom of the wall case.

Never fasten screws or put other holes in the bottom of the wall case.

If the wall opening is greater than the case dimensions, spacers must be used on the sides between the wall case and the wall support structure to prevent distorting the wall case.

3. Caulk or gasket the entire opening on the outside between the wall case and exterior wall surface (4 sides) to provide total water and air seal.

4. Caulk or gasket room-side opening between wall case and interior wall surface (4 sides). Opening beneath or around the wall case can allow outdoor air to leak into the room resulting in increased operating costs and improper room temperature control.

Care should be taken in location of electrical supply entry in relationship to wall sleeve to assure access to receptacle or junction box once unit is installed.

6RWU0-03A Installation of unit

Installation PTAC 60

Installation of unit 6RWU0-03A

61 PTAC Installation

6RWU0-03A

• unit installation

1. Remove the shipping screw from the ventilation door.

2. Remove the front gille by pulling it out at the bottom to release it, then lift it up along the unit top front.

3. Slide the unit into the wall sleeve and secure with

6 screws through the unit flange holes.

4. Reinstall the front grille by hooking the top over the unit top, then pushing it in at the bottom.

• Failure to follow this caution may result in equipment damage or improper operation.

• Blocking indoor(curtain or bedclothes etc.) or outdoor discharge air could cause premature failure of unit.

Installation PTAC

IN

Installation of unit

IN

62

Installation of unit 6RWU0-03A

ELECTRICAL SAFETY

IMPORTANT

(PLEASE READ CAREFULLY)

FOR THE USER'S PERSONAL SAFETY, THIS APPLI-

ANCE MUST BE PROPERLY GROUNDED

PREFERRED METHOD

The power cord of this appliance is equipped with a threeprong (grounding) plug. Use this with a standard three-slot

(grounding) wall power outlet to minimize the hazard of electric shock. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded.

DO NOT CUT OR REMOVE THE THIRD (GROUND)

PRONG FROM THE POWER PLUG.

Ensure proper ground exists before use

FUSE – Use a time – delay fuse or circuit breaker. Refer to the nameplate for proper power supply requirements.

Use Wall Receptacle

CAUTION

1. Do not use an extension cord with this unit.

2. When the unit is in the OFF position, the power supply to the electrical controls is still energized.

3. Disconnect the power to the unit before servicing the unit.

4. Remove the power cord from the wall receptacle.

5. Remove or turn off the protective device (fuses or circuit breaker).

Standard 208/230V, 3-wire grounding receptacle rated 15A

Standard 208/230V, 3-wire grounding receptacle rated 20A

Power Supply

Use 15 AMP. time delay fuse or 15 AMP.

Circuit breaker.

Use 20 AMP. time delay fuse or 20 AMP.

Circuit breaker.

(2500W Heater ơ 15Amp

Circuit Breaker)

Use 30 AMP. time delay fuse or 30 AMP.

Circuit breaker.

Wirings including installation of the receptacle must comply with the

NEC and local codes, local regulations.

FUSE - Use a time-delay fuse or circuit breaker. Refer to the nameplate for proper power supply requirements.

Standard 208/230V, 3-wire grounding receptacle rated 30A

Standard 265V grounding receptacle rated 20A

Use 20AMP,time delay fuse or 20AMP

Circuit breaker

(2000W Heater ơ 15Amp

Circuit Breaker)

Use 25AMP,time delay fuse or 25AMP

Circuit breaker Standard 265V grounding receptacle rated 25A

Installation(for 60Hz)

• Electric installation requirement for personal safety:

• This equipment must be properly connected to ground.

Standard 265V grounding receptacle rated 30A

• Under no circumstances cut or break the grounder conductor.

• We recommend not to use an extension wire or any adaptor with this product.

Use 30AMP, time delay fuse or 30AMP

Circuit breaker

• Follow the national or local electric codes.

• If the power supply does not fulfill the specifications previously mentioned, call an authorized electrician.

• The aluminum wired in the houses may bring about some problems, call an authorized electrician.

• This unit requires a separated power supply that works only for this application.

63 PTAC Installation

Part 4 Accessories

1 Controller accessories .......................................................................65

1.1 Hard Wire kit .....................................................................................................65

1.2 Wired Wall Thermostat Connection Kit .............................................................67

2 Mechanical accessories .....................................................................68

2.1 Stamped Aluminum Grille - Single Pack ...........................................................68

2.2 Remote Escutcheon Kit - 10 Pack ....................................................................69

2.3 Replacement Filter - 10 Pack ...........................................................................70

2.4 Vent Filter ........................................................................................................70

Controller accessories

1. Controller accessories

1.1 Hard Wire Kit

The Hard Wire kit consists of a Junction box which provides a protective enclosure for the electrical connections. This junction box is furnished with approximately 2 - 1 /

2 feet of 1 /

2 inch flexible steel conduit and a metal box that secures to the

PTAC at the control panel. The Hard Wire kit connects the

PTAC directly to the building power supply wires and the junction box is intended to be mounted on the wall or the floor near the PTAC.

6RWU0-03A

Hardwire Kit

AYHW101

Installation Procedure:

The Installation and servicing of the equipment should be performed by qualified and experienced personnel only.

1) At first, remove the cover plate from the junction box.

Then, mount the junction box on the wall or floor within 28 inches (711mm) from the lower right corner of the wall sleeve so that the metal box is suitably clamped on the side of the sleeve as shown on the right below.

2) If a power switch is to be used, make sure the electrical connections are done and then mount the switch onto the junction box. During this operation, refer to the Power

Switch Installation instructions.

3) Remove the control panel assembly by removing the two screws holding the control panel in place and then gently lift the panel. Disconnect the power cord leads from all electrical connections including the ground wire.

4) Remove the power cord clamp and the power cord from the unit.

Cover plate

Wall Sleeve

Ground Wie with Eyelet

Terminal

28 Inch es Max

Conduit

Power Leads with Push on

Connectors

Metal Box with Straight Clamp

Control Panel

Base Pan

Bracket

6RWU0-03A Controller accessories

5) Now for 208/230 volt units, remove and discard the white lead from the wire assembly. For 265 volt units, remove and discard the red lead from the wire assembly.

* For 208/230 volt units and 265 volt units refer to notes given below.

6) Remove the retaining ring, which holds the threaded conduit and the metal box together, from the straight conduit clamp.

Insert the three wires into the metal box through one of the two openings in the box. Replace the hole cover grommet into the unused hole to prevent objects from entering the box.

7) After inserting the wires, replace the retaining ring back on the conduit clamp inside the metal box and tighten the ring securely so that it holds the conduit firmly.

8) The three wires extending from the metal box to the incoming power opening are inserted in such a way that approximately 20inches (508mm) of the wires protrude through the opening.

9) Attach the metal box to the chassis once again. Then, finally insert the wire tie into the _ inch diameter hole located just above the incoming power opening. Tie all wires together securely with the wire tie as shown in the figure below.

Right Side of Chassis

Wire Tie

3/16 Inch

Diamenter Hole

Electrical Supply Wires

Back of Control Panel

208 / 230 Volt Units

a) After removing the white lead from the wire assembly, connect the black lead to the line-2 terminal on the control board.

b) Connect the red lead to the common (C) terminal of the capacitor and then connect the ground wire to the partition panel where the ground wire of the power cord was located earlier. For grounding, use the supplied ground screw (green color).

c) Then connect the red lead wire of the wire assembly at the junction box to the red lead of the field power source and similarly, connect the black lead of the wire assembly at the junction box to the black lead of the field power source. After that connect the ground wire too from the field power source to the ground wire of the wire assembly at the junction box.

d) Install the junction box cover plate and reinstall the control panel assembly.

265 Volt Units

a) After removing the red lead from the wire assembly, connect the black lead to the center terminal of the fuse holder.

b) Connect the white lead to the common (C) terminal of the capacitor and then connect the ground wire to the partition panel where the ground wire of the power cord was located earlier. For grounding, use the supplied ground screw (green color).

c) Then connect the white lead wire of the wire assembly at the junction box to the white lead of the field power source and similarly, connect the black lead of the wire assembly at the junction box to the black lead of the field power source. After that connect the ground wire too from the field power source to the ground wire of the wire assembly at the junction box.

d) Install the junction box cover plate and reinstall the control panel assembly.

Mechanical accessories

1.2 Wired Wall Thermostat Connection Kit

The PTAC Wire Harness kit provides connection from the 6pin terminal strip on the PTAC control board to the following board features:

• Energy Management*

• Front Desk Control*

• Remote Fan (relay must be manufacturer-approved and have a AC low voltage coil)

• Remote Thermostat (confirm with manufacturer approved).

* If other than a "dry switch" is used in connecting these features, consult manufacturer before proceeding.

6RWU0-03A

Installation

1. Disconnect power and remove the front panel per unit installation instruction.

2. Using Table 1 as a guide, choose the feature desired and insert the proper jumper wire (included) into the appropriate slot on the housing.

3. Install the appropriate maleconnector header onto the matching on-board female connector.

4. Connect the kit wiring to the field wiring using the wire nuts (included). Route the kit wiring as shown in Figure 2.

Do not run wires through basepan or wall

The PTAC Wire Harness kit contains the following:

1. 4-pin connector for an optional zone sensor

• MODE

• GND

• CSP

• ZONE

2. 7-pin connector for a thermostat connection

• C - Cormmon

• R - 24VAC

• Y - Compressor

• W - E/Heater

• O - Reversing Valve (only on TPHP)

• GH - High Speed Fan

• GL - Low Speed Fan

Note: If there is only one Fan connection(G), connect to either GH or GL depending on desired fan speed.

Figure 1

Wire Nuts (x6)

Table 1

Feature

Motion Sensor

Pins Used

MS1, MS2

Door Switch DR1, DR2

Front Desk Control FD1, FD2

Figure 2

Wires (x6)

OC1

OC2

DR1

DR2

RF1

RF2

FD1

FD2

MODE

CSP

GND

ZONE

The PTAC Wire Harness kit contains the following:

1. 6-pin connector for the following options

• FD1 and FD2 - Front Desk Control

• MS1, MS2, DR1, and DR2 - Energy Management

System (connections available for occupancy sensor and door switch)

2. 6 wire nuts

3. 6 wires

6RWU0-03A

2. Mechanical Accessories

Mechanical accessories

2.1 Stamped Aluminum Grille – Single Pack

Outdoor Grilles are attached to the Wall Sleeve and exposed to the exterior Wall. These Grilles comes in industry standard size of 42" x 16". These Grilles are of two types :

(a) Stamped Aluminum Grille

Stamped Aluminum Grille

AYRGALA01

Installation Procedure:

The Installation and servicing of the equipment should be performed by qualified and experienced personnel only.

(a) Stamped Aluminum Grille.

1) Prepare the wall sleeve for installation of the Grille by removing the cardboard stiffener and rear enclosure panel from the sleeve. These items may be removed from the inside of the room.

Note: -

The Sleeve stiffener must be taken out before the rear sleeve enclosure panel can be removed from the sleeve.

2) Prepare the stamped Aluminum Grille for installation on the sleeve by inserting the six plastic grommets into the square holes located near the outer edges of all the four sides of the Grille. Now with the Grille positioned so that the flanges of all the four sides are in the up position (at 90 degrees), insert the grommets in the opposite direction so that their square end protrudes through the grille through the flanges. The Grille is installed in such a way that it could be removed through the rear sleeve opening.

3) Install the stamped Aluminum Grille by aligning the guide pins located in the lower right and left hand corners of the

Grille with the corresponding holes in the rear of the wall sleeve.

4) Secure the Grille by threading each of the screws into the plastic grommets.

5) Remove the wire handle from the center of the grille prior to installing the chassis into the sleeve.

Mechanical accessories

2.2 Remote Escutcheon Kit

This kit provides an attractive replacement escutcheon,

(see Figure 1). The kit allows the removal of control knobs and graphics, which are not required when a wall thermostat is used to control the unit.

3. Lift the cabinet front off the chassis.

4. Lifting the front edge of the escutcheon.

Figure 3

Figure 1 - Standard Escutcheon

6RWU0-03A

Figure 2

5. Replace the escutcheon with the one from control panel.

Figure 4

Escutcheon

Lift off

1. Grasp the cabinet front as shown in Figure 2.

2. Pull the bottom of the cabinet front away from the chassis until the retaining clips disengage as in Figure 3.

6RWU0-03A

2.3 Replacement Filter (10 Pack)

The unit is provided with two easy-to-use replaceable mesh filters which can be cleaned periodically form time to time.

Mechanical accessories

2.4 Vent Filter

The Vent filter is used to filter the air flowing inside the room when Air Ventilation is performed by means of the ventilation lever.

Installation Procedure:

The Installation and servicing of the equipment should be performed by qualified and experienced personnel only.

Before cleaning the vent filter, disconnect power to the unit by unplugging the power cord at the wall outlet or subbase, or disconnect power at the fuse box or circuit breaker. If unit is operated with vent door closed, the vent filter does not need to be cleaned.

1. Remove the cabinet front as described in Front

Removal.

2. Remove the six screws securing the chassis to the wall sleeve with a Phillips-Head screwdriver.

3. Slide the chassis out of the wall sleeve far enough so that the vent filter is accessible as shown in Figure A.

4. Remove the vent filter by unscrewing the two screws at the top of the filter and gently pulling the filter away from the partition panel. Refer to Figure B.

5. Clean and replace the filter by reattaching the hook to the bottom of the vent door and replacing the two screws, slide the chassis back into the wall sleeve, secure it in place with six screws and reinstall the front cabinet.

Note:

Vent filter supplied as SVC Part not as an accessories part. Vent Filter can requested by Part Number

5230A20016A

Replacement Filter 10-Pack

AYFT110

Figure A – Vent (Left side of unit)

Figure B – Vent Filter Removal

P/No.: MFL67884604

Air Conditioner

20 Yeouido-dong, Yeongdeungpo-gu,

Yeouido P.O.Box 335 Seoul,

150-721, Korea.

http://www.lgeaircon.com

All rights reserved

Printed in Korea March/2013

The specifications, designs, and information in this brochure are subject to change without notice.

The air conditioners manufactured by LG have received ISO9001 certificate for quality assurance and ISO14001 certificate for environmental management system.