Emerson Quiet Kool EARC8RSE1 8,000 BTU 115-Volt Window Air Conditioner Instructions


Add to my manuals
20 Pages

advertisement

Emerson Quiet Kool EARC8RSE1 8,000 BTU 115-Volt Window Air Conditioner Instructions | Manualzz

MODEL:

EARC6RE1

EARC8RE1

EARC8RSE1

EARC10RE1

EARC12RE1

INTRODUCTION

IMPORTANT SAFETY INSTRUCTION ...........................................................................

1

ELECTRICAL REQUIREMENTS

...................................................................................

2

PACKING LIST ............................................................................................................

3

INSTALLATION & ASSEMBLY INSTRUCTIONS .............................................................

4

USING YOUR AIR CONDITIONER ................................................................................

9

OPERATING YOUR AIR CONDITIONER

........................................................................

11

CARE AND CLEANING ................................................................................................ 12

TROUBLESHOOTING .................................................................................................

13

below:

1

(6K-8K) 0-8 amps

(10K-12K) 0-12 amps

(6K-8K) 10-amp

(10K-12K) 15-amp

2

3

8

FIG. 1

INTERIOR

WALL

STOOL

SILL

OFFSET

EXTERIOR

WALL

0

FIG. 2

INTERIOR

WALL

STOOL

SILL

OFFSET

EXTERIOR

WALL

4

(Only used for 6K/8K)

Head

6K-8K

10K-12K

5

Head

FIG. 3

3

6

FIG. 5

FIG. 4

(Suggest to keep a downward angle , to let accumulated rain water to drain out, from back side of the unit bottom.)

FIG. 6

FIG. 10

FIG. 11

FIG. 7

FIG. 12

FIG. 8

FIG. 13

FIG. 9

7

FIG. 14

8

WIFI Symbol*

AUTO

SPEED

WIFI

9 8

1

7 6

AUTO

MODE

5 4

2

3

Only available for WIFI models.

NOTE: * means only available for WIFI modes, For more

information, please see the WIFI manual.

1. Shows the set temperature.

Operation modes are: Cool, Dry, Fan, and Auto.

Time is displayed using the timer setting.

Cool Mode:

The cooling function allows the air conditioner to cool the room and at the same time reduces humidity. Press the MODE button to activate the cooling function. To optimize this function adjust the temperature by pressing the up and down arrows and the speed by pressing the

Fan Speed button.

Dry Mode:

This function reduces the humidity of the air to make the room more comfortable. Press

MODE button to set the DRY mode. An automatic function of alternating cooling cycles and air fan is activated.

Fan Mode:

This mode will only circulate the air.

Press MODE button to select FAN MODE.

Pressing the FAN SPEED button allows you to change the fan speed setting from HI, MED, and

LO. If using the remote control, it will store the fan speed setting of the previous use.

Auto Mode:

In AUTO mode the unit automatically chooses the fan speed and the mode of operation

(COOL, DRY, or FAN). In this mode the fan speed and the temperature are set automatically according to the room temperature ( Room temperature is determined by the temperature sensor located in the indoor unit.

).

5.

Use buttons on the control panel and remote to set the TIMER.

Timer Off:

The timed stop is programmed by pressing the TIMER button. Set the stop time by pressing the button or until your desired stop time is displayed, then press TIMER button again.

Timer On:

When the unit is off, press TIMER button first , set the temperature with pressing

Press TIMER button a second time, set the stop time with pressing the third time, confirm your settings and stop time.

The display will show the time your machine will automatically turn on.

control panel and remote to increase or decrease the Set Temperature or Timer.

Temperature range: 61 ~88 or 16 ~31 .

off.

Note:

It can be set to automatically turn off or on in

0.5-24 hours. Each press of the buttons will increase or decrease the timer. The

Timer can be set in 0.5 hours increment below 10 hours and 1 hour increment for 10 hours or above.

The SET light will turn on while setting.

To cancel the set function, press the TIMER button again.

4.

Press the mode button to cycle through the various modes: Cool, Dry, Fan and

Auto.

9

6.

When the unit is in ECO mode, the light will turn on. In ECO mode, the unit will turn-off once the room is cooled to the user set temperature. The fan will also be off at this point.

The unit will turn back on when the room temperature rises above the user set temperature.

Before the compressor stars, the fan motor will run for a while, then it will stop for a while-and will repeat to provide a much more comfortable-feeling and save energy.

10.

Use the horizontal wheels to control horizontal airflow and the air deflectors to control vertical airflow.

air deflector horizontal wheel air deflector

7.

Press the SLEEP button, the Sleep

Light will be on after 10s. and the remaining lights on the display will be off. In SLEEP mode, the airconditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise by 1 every 30-60 minutes and at most change six times until the set temperature is 28 .

Run time will depend on set temperature.

8.

Fan Speed Button:

Press the FAN SPEED button to select the fan speed. In COOL MODE you can choose the following settings: HI, MED, LO, or

AUTO. In FAN MODE you can choose from HI,

MED, and LO.

9.

Fiter Button:

The Filter Check light will only turn on as a reminder to clean the filter after the fan motor has been in operation for a total of 500 hours. To turn the light off, press the Filter Check

button.

10

1

5

6

3

2

5.

Use buttons on the control panel and remote to set the TIMER.

Timer Off:

The timed stop is programmed by pressing TIMER button. Set the stop time by pressing the button or until your desired stop time is displayed, then press TIMER button again.

Timer On:

When the unit is off, press TIMER button first , set the temperature with pressing

Press TIMER button a second time, set the stop time with pressing the

3

4

7

8

9

10 panel and remote to increase or decrease the

Set Temperature or Timer. Temperature range:

61 ~88 or 16 ~31 .

4.

Press the SLEEP button, the Sleep

Light will be on after 10s. and the remaining lights on the display will be off. In SLEEP mode, the air-conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise by 1 every 30-60minutes and at most change six times until the set temperature is 28 .

And every Run time will depend on set temperature.

third time, confirm your settings and stop time.

The display will show the time your machine will automatically turn on.

Note:

It can be set to automatically turn off or on in

0.5-24 hours. Each press of the buttons will increase or decrease the timer. The

Timer can be set in 0.5 hours increment below 10 hours and 1 hour increment for 10 hours or above.

The SET light will turn on while setting.

To cancel the set function, press the TIMER button again.

6.

In AUTO mode the unit automatically chooses the fan speed and the mode of operation

(COOL, DRY, or FAN). In this mode the fan speed and the temperature are set automatically according to the room temperature ( Room temperature is determined by the temperature sensor located in the indoor unit.

).

7.

Fan Speed:

Press the FAN SPEED button to select the fan speed. In COOL MODE you can choose the following settings: HI, MED, LO, or

AUTO. In FAN MODE you can choose from HI,

MED, and LO.

8.

To press the DISPLAY button, it can switch off/on all lights or LED display.

9.

light will turn on. In ECO mode, the unit will turn-off once the room is cooled to the user set temperature. The fan will also be off at this point.

The unit will turn back on when the room temperature rises above the user set temperature.

Before the compressor stars, the fan motor will run for a while, then it will stop for a while-and will repeat to provide a much more comfortable-feeling and save energy.

10.

ONLY mode.

11

The

Check Filter light will automatically turn on after the fan motor has been in operation for a total of

500 hours.

15

FIG. 15

12

13

For any questions or Technical Support,

Please Call Customer Service:

1-844-801-8880

14

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement