UPG UB1290F2 12-Volt 9 Ah F2 Terminal Sealed Lead Acid (SLA) AGM Rechargeable Battery Guide


Add to my manuals
2 Pages

advertisement

UPG UB1290F2 12-Volt 9 Ah F2 Terminal Sealed Lead Acid (SLA) AGM Rechargeable Battery Guide | Manualzz

Sealed Lead-Acid Battery

Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. U.L. recognized under file number MH 20567.

UPG No. 40748

UB1290

Maintenance-Free

Specification

Nominal Voltage

Nominal Capacity

12 volts

77º F (25º C)

9.00 Ah

8.30 Ah

7.69 Ah

5.40 Ah

5-hr. (1.54 A)

1-hr. (5.40 A)

Approximate Weight

Internal Resistance (approx.)

5.17 lbs (2.35 kgs)

19m Ÿ

Shelf Life (% of normal capacity at 68º F (20º C)

3 Months

91%

6 Months

83%

Temperature Dependancy of Capacity

104 F (40 C) 77 F (25 C) 32 F (0 C)

102% 100% 85%

AGM Operational Temperature

Charge

Discharge

AGM Storage Temperature

32 F to 104 F

5 F to 113 F

5 F to 104 F

12 Months

64%

(20 hour rate)

5 F (-15 C)

65%

(0 C to 40 C)

(-15 C to 45 C)

(-15 C to 40 C)

Due to continuous improvements to our products, product may vary slightly from depiction.

Charge Method (Constant Voltage)

Cycle Use (Repeating Use)

Initial Current

Control Voltage

Float Use

Control Voltage

2.7 A or smaller

14.6 - 14.8 V

13.6 - 13.8 V

Physical Dimensions: in (mm)

Terminals

5.94 (151)

L: 5.94 in (151 mm)

W: 2.56 in (65.0 mm)

H: 3.78 in (96.0 mm)

TH: 4.06 in (103 mm)

Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice.

7.9 mm

0.31in

6.4 mm

0.25 in

8.2 mm

0.32 in

.8 mm

0.03 in

Discharge Characteristics Discharge Time vs. Discharge Current

Discharge Current = CA X Nominal Capacity

(Minute)

Discharge time

(Hour)

www.upgi.com

All specifications subject to change without notice.

488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 [email protected]

J2021-1

Copyright 2020 Universal Power Group. All rights reserved.

UPG No. 40748

UB1290

Maintenance-Free

Cycle Life vs Depth of Discharge Shelf Life & Storage

Open Circuit Voltage vs Residual Capacity Effect of Temperature on Capacity

Charge Current & Final Discharge Voltage

Application

Cycle Use

Standby 25 (77 )

Charge Voltage(V/Cell)

Temperature Set Point Allowable Range

25 (77 ) 2.45

2.40~2.47

2.28

2.27~2.30

Max.Charge Current

0.30C

Final Discharge

Voltage V/Cell

Discharge

Current(A)

1.75

1.70

1.60

1.30

0.2C>(A) 0.2C<(A)<0.5C

0.5C<(A)<1.0C

(A)>1.0C

Let UPG Power Your Life.

www.upgi.com

488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 [email protected]

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement