Sealed Lead-Acid Battery
Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. U.L. recognized under file number MH 20567.
UPG No. 40748
UB1290
Maintenance-Free
Specification
Nominal Voltage
Nominal Capacity
12 volts
77º F (25º C)
9.00 Ah
8.30 Ah
7.69 Ah
5.40 Ah
5-hr. (1.54 A)
1-hr. (5.40 A)
Approximate Weight
Internal Resistance (approx.)
5.17 lbs (2.35 kgs)
19m
Shelf Life (% of normal capacity at 68º F (20º C)
3 Months
91%
6 Months
83%
Temperature Dependancy of Capacity
104 F (40 C) 77 F (25 C) 32 F (0 C)
102% 100% 85%
AGM Operational Temperature
Charge
Discharge
AGM Storage Temperature
32 F to 104 F
5 F to 113 F
5 F to 104 F
12 Months
64%
(20 hour rate)
5 F (-15 C)
65%
(0 C to 40 C)
(-15 C to 45 C)
(-15 C to 40 C)
Due to continuous improvements to our products, product may vary slightly from depiction.
Charge Method (Constant Voltage)
Cycle Use (Repeating Use)
Initial Current
Control Voltage
Float Use
Control Voltage
2.7 A or smaller
14.6 - 14.8 V
13.6 - 13.8 V
Physical Dimensions: in (mm)
Terminals
5.94 (151)
L: 5.94 in (151 mm)
W: 2.56 in (65.0 mm)
H: 3.78 in (96.0 mm)
TH: 4.06 in (103 mm)
Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice.
7.9 mm
0.31in
6.4 mm
0.25 in
8.2 mm
0.32 in
.8 mm
0.03 in
Discharge Characteristics Discharge Time vs. Discharge Current
Discharge Current = CA X Nominal Capacity
(Minute)
Discharge time
(Hour)
www.upgi.com
All specifications subject to change without notice.
488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 [email protected]
J2021-1
Copyright 2020 Universal Power Group. All rights reserved.
UPG No. 40748
UB1290
Maintenance-Free
Cycle Life vs Depth of Discharge Shelf Life & Storage
Open Circuit Voltage vs Residual Capacity Effect of Temperature on Capacity
Charge Current & Final Discharge Voltage
Application
Cycle Use
Standby 25 (77 )
Charge Voltage(V/Cell)
Temperature Set Point Allowable Range
25 (77 ) 2.45
2.40~2.47
2.28
2.27~2.30
Max.Charge Current
0.30C
Final Discharge
Voltage V/Cell
Discharge
Current(A)
1.75
1.70
1.60
1.30
0.2C>(A) 0.2C<(A)<0.5C
0.5C<(A)<1.0C
(A)>1.0C
Let UPG Power Your Life.
www.upgi.com