Fixture

Light Source

Number of LEDs

Color Temperature

Color Rendering Index

Integrated LED

1 High Output COB

2700K, 3000K

80+

Beam Angles

Binning

15º, 35º, 60º

3 Step

Fixture can be used in UP or DOWN position

Input

Input Voltage Range

Input Frequency

Input Current

Inrush Current

Efficiency

Power Factor

9 – 15V

AC or DC with no loss in light output

47 – 63Hz

2.55A Max @ 9VAC

9A Max

> 70L/W @ 12VDC

> 0.7 @ 15V

Output

Lumen Level 3 (max)

Lumen Level 2 (mid)

Lumen Level 1 (standard)

835

600

400 (factory setting)

Environmental

Environmental Protection Rating Wet, IP 66

Operation Ambient Temperature -25ºC - +40ºC

Expected Life Time (L70) 50K Hours

Mechanical & Housing Specification

Length

Width

Height

Housing Material

Housing Color & Surface

Weight

6" / 154 mm

2.7" / 69 mm

4.2" / 106 mm

Aluminum, Brass

AZT, BKT, CBR, WHT

Alum 24 oz/ 0.7Kg,

Brass 48oz/ 1.4Kg

FEATURES

• High lumens in small body

• Variable lumen output

• Advanced optics provide superb center to edge uniformity

• Available beam angle: 15º, 35º & 60º

• Complete sealed system for improved reliability

• Advanced ESD protection (6 kV)

• IP66 rated

PERFORMANCE

Output Position

Lumen output

Input voltage

Power (VA) @ 15VAC

Level

1

400

9-15

8.5

Level

2

600

9-15

12.5

Power (W) @ 15VDC 5.25

8.5

Efficacy (Lm/W @DC) 76 70

Level

3

835

9-15

17

12

69

FIXTURE

Glass Lens

Tempered, shock resistance glass with high tolerance for thermal expansion and stress.

Body

A380 Aluminum, C360 Brass casting

Wire

18 AWG, SPT-1W, 105ºC, 300V, 48” useable length

Optics

Polycarbonate TIR lens provides superior fixture beam angle. Available in 15º, 35º and 60º.

Included Accessories

Includes 8” slotted in-ground stake, 2 gel-filled wire nuts and lumen switching magnetic key.

Dimensions

6.08"

AVAILABLE FINISHES

AZT

Textured

Architectural

Bronze

BKT

Textured

Black

CBR

Centennial

Brass

115˚

WHT

Textured

White

(35º only)

17-LD-4897 122117 v8

12V LED Large Accent Light with Variable Lumen Output (VLO)

INSTALLATION INFORMATION

Type

Supply

AC

Voltage

(VA)

DC

Voltage

(W)

Voltage

Level

9V

12V

15V

9V

12V

15V

1

8

6

5.5

9

9

5.5

Dimming Level

2

12

9

8

13

13

8

3

17

17.5

18

12.5

12

12

Power

(W)

0-20

40

60

80

100

>100

Ordering Guide

(product number breakdown)

1

Item Number for Fixture

Size & Beam Angle:

16018 = Small 15º Spot

16019 = Small 35º Flood

16020 = Small 60º Wide Flood

2

Finish:

10

1860/567

Wire Gauge / Length / (ft/m) Load Chart

12

1150/351

14

730/223

16

450/137

930/283

620/189

470/143

370/113

580/177

390/119

290/88

230/70

370/113

240/73

180/55

140/43

Consult Technical Support

230/70

150/46

110/34

90/27

Product

AZT = Textured Architectural Bronze

BKT = Black

CBR = Centennial Brass

WHT = Textured White (only in 35º)

3

Color

16018-16020

Temperature:

27 = 2700K, Warm White

30 = 3000K, Pure White

Example: 16018 CBR 30

1 6 0 1 8 C B R 3 0

Item

Number

Beam Angle

Max Candela

Ft. Away

8'

12'

24'

36'

48'

60'

Item

Number

Beam Angle

Max Candela

Ft. Away

8'

12'

24'

36'

48'

60'

Item

Number

Beam Angle

Max Candela

Ft. Away

8'

12'

24'

36'

48'

60'

16018 (low)

15° Spot

3521

Foot-candles

40.2

17.9

4.5

2

1.1

.7

16018 (mid)

Beam Width

2.1

3.2

6.3

9.5

12.6

15.8

Foot-candles

74.7

33.2

8.3

3.7

2.1

1.3

15° Spot

4925

Beam Width

2.1

3.2

6.3

9.5

12.6

15.8

16018 (high)

Foot-candles

100.8

44.8

11.2

5

2.8

1.8

15° Spot

6576

Beam Width

2.1

3.2

6.3

9.5

12.6

15.8

Ft.

4'

8'

16'

24'

32'

40'

Ft.

4'

8'

16'

24'

32'

40'

Ft.

4'

8'

16'

24'

32'

40'

16019 (low)

35° Flood

948

Foot-candles

37.3

9.3

2.3

1

.6

.4

16019 (mid)

Beam Width

2.5

4.9

9.8

14.7

19.6

24.5

Foot-candles

65.6

16.4

4.1

1.8

1

.7

35° Flood

1315

Beam Width

2.5

4.9

9.8

14.7

19.6

24.5

16019 (high)

Foot-candles

86

21.5

5.4

2.4

1.3

.9

35° Flood

1816

Beam Width

2.5

4.9

9.8

14.7

19.6

24.5

Ft.

4'

8'

16'

24'

32'

40'

Ft.

4'

8'

16'

24'

32'

40'

Ft.

4'

8'

16'

24'

32'

40'

16020 (low)

60° Wide Flood

396

Foot-candles

17.1

4.3

1.1

.5

.3

.2

16020 (mid)

Beam Width

4.9

9.8

19.6

29.4

39.2

49

60° Wide Flood

560

Foot-candles

29.1

7.3

1.8

.8

.5

.3

Beam Width

4.9

9.8

19.6

29.4

39.2

49

16020 (high)

60° Wide Flood

750

Foot-candles

40.8

10.2

2.6

1.1

.6

.4

Beam Width

4.9

9.8

19.6

29.4

39.2

49

12V LED Large Accent Light with Variable Lumen Output (VLO) 16018-16020

TROUBLESHOOTING

Fixture does not illuminate

Fixture flashes

Fixture turns off

Fixture trips breaker

Fixture returns to original lumen output

Verify power connections. Review installation guide for installation problem. Insure manual reset breaker has not been tripped.

Verify load calculations for the installation. Check voltage at affected fixture. Verify you are on

15V output tap.

Verify power connections. Review installation guide for installation problems. Insure manual reset breaker has not been tripped. Check voltage drop at fixture.

Check installation for a possible short or overload state. Isolate the identified short and replace affected fixture or remove fixture(s) installed in overload.

The fixture has to be powered on for 2 minutes after final adjust to exit programming mode.

LISTING

UL 1838 Issued: 2003/01/13 Ed: 3 Rev: 2015/01/13

Low Voltage Landscape Lighting Systems.

CSA C22.2#250.7 Issued: 2007/11/01 (R2012)

Ed: 1 Extra-low-voltage landscape lighting systems –

General Instruction No. 1: 2008.

Contact: [email protected]

1.

Chip binning ranges: (2700K 80+ CRI: 3 step), (3000K 80+ CRI: 3 step). LED chip data measured in accordance to IES LM-80

2.

Fixture has a 90% confidence luminous flux range to stated 3000K CCT target. Photometric

(flux and color) data has been measured in accordance to IES LM- 79.

3.

Actual efficacy value can be calculated as follows: Lumen value divided by average power consumption.

4.

Do not extend beyond the recommended maximum run length.

5.

Recommend product be installed with 10 or 12 gauge wire.

6.

Recommend 80% load/20% overhead rule for fixture load planning in reference to the power source.

Calculating fixture loading this way provides additional resource for fixture adjustment and loss due to voltage drop due to wire run lengths.

7.

We reserve the right to modify and improve the design of our fixtures without prior notice. We cannot guarantee to match existing installed fixtures for subsequent orders or replacements in regards to product appearance, CCT, or lumen output.

8.

Do not modify product beyond instructions or warranty will be void.

WARRANTY

See Kichler.com/Warranty for warranty details.

Consult Kichler Advanced Product Solutions for additional product support and design layouts by visiting Kichler.com/APS.

© The L.D. Kichler Co. Kichler® All rights reserved.

ST17LD4897 | LD20010

AZT BKT CBR

Visit Kichler.com/VLOaccent

WHT

( 35º only)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement