12V Textured Bollard Path Light

PROJECT:

TYPE:

ORDERING:

COMMENTS:

15848

OVERVIEW

The Swooping Bollard features a textured surface that reflects a soft, uniform light. Great for illuminating walkways, pathways, and driveways. This fixture combines clean and modern design with robust and durable constructions.

FEATURES

• Thick, robust cast construction

• Textured diffusion lens for glare control and uniform light spread

• No visible seams or screws

• Optimized socket location, easy to lamp

SPECIFICATIONS

Fixture/Housing

Height

Length

Width

Housing Material

Weight Alum

27" / 685.80mm

5.50" / 140mm

4" / 102mm

Cast Aluminum

7.8 lbs / 3.5 kg

Lamp Base

Lamp Base

Electrical

Input Voltage Range

Wattage

12V S8 Wedge Base

Wire

36" of usable #18-2, SPT-1W leads

Ratings/Certification

Wet Locations

9 – 15V

11.5W

FIXTURE

Lens

Polycarbonate Diffusion Lens for even light dispersion and glare control.

Included Accessories

15276 BK - Power Post®

15601 - Surface Mounting Flange (needed for attachments to junction box)

Notes

Fixtures include an 14" in-ground slotted stake and gel-filled cable connectors. Lamps sold separately.

AVAILABLE FINISHES

AZT

Textured

Architectural

Bronze

BKT

Textured

Black

12V Textured Bollard Path Light

DIMENSIONS

18123

5.5"

27"

PHOTOMETRICS

Distance from Light

Footcandles

0’

4"

1’

8.5

2.7

2’ 3’ 4’ 5’ 6’ 7’ 8’

1 0.35 0.15

0.1 0.05 0.03 0.01

15848

RECOMMENDED LED LAMPS* (sold separately)

18122 1.5W, 2.4VA, 2700K, 130 lumnes, 120° Beam

18123

18202

1.5W, 2.4VA, 3000K, 130 lumnes, 120° Beam

2.3W, 3.3VA, 2700K, 215 lumnes, 300° Beam

18203 2.3W, 3.3VA, 3000K, 215 lumnes, 300° Beam

* Power usage at 12V AC Input

INSTALLATION

INFORMATION

TROUBLESHOOTING

Fixture does not illuminate

Fixture turns off

Fixture trips breaker

Power (W)

0-20

40

60

80

100

>100

10

1860/567

930/283

620/189

470/143

370/113

Wire Gauge / Length / (ft/m) Load Chart

12 14

1150/351 730/223

580/177

390/119

370/113

240/73

290/88 180/55

230/70 140/43

Consult Technical Support

16

450/137

230/70

150/46

110/34

90/27

Verify power connections. Review installation guide for installation problem. Insure manual reset breaker has not been tripped.

Verify power connections. Review installation guide for installation problems. Insure manual reset breaker has not been tripped. Check voltage drop at fixture.

Check installation for a possible short or overload state. Isolate the identified short and replace affected fixture or remove fixture(s) installed in overload.

LISTING

UL 1838 Issued: 2003/01/13 Ed: 3 Rev: 2015/01/13 Low Voltage Landscape Lighting Systems.

CSA C22.2#250.7 Issued: 2007/11/01 (R2012)

Ed: 1 Extra-low-voltage landscape lighting systems – General Instruction No. 1: 2008.

Contact: [email protected]

1.

Actual efficacy value can be calculated as follows: Lumen value divided by average power consumption.

2.

Do not extend beyond the recommended maximum run length.

3.

Recommend product be installed with 10 or 12 gauge wire.

4.

Recommend 80% load/20% overhead rule for fixture load planning in reference to the power source. Calculating fixture loading this way provides additional resource for fixture adjustment and loss due to voltage drop due to wire run lengths.

5.

We reserve the right to modify and improve the design of our fixtures without prior notice. We cannot guarantee to match existing installed fixtures for subsequent orders or replacements in regards to product appearance, CCT, or lumen output.

6.

Do not modify product beyond instructions or warranty will be void.

WARRANTY

See Kichler.com/Warranty for warranty details.

Consult Kichler Advanced Product Solutions for additional support at 844-452-5437.

© 2019 Kichler Lighting LLC. All Rights Reserved.

LD18047

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement