EMX NIR-50-325 PhotoEye
INSTALLATION AND PROGRAMMING INSTRUCTIONS
The NIR-50-325 retroreflective photoeye (Nice P/N MX4257) has an operating range up to 50 feet, operates over a voltage range of 12-30VDC and 24-30VAC, and is capable of normally closed
(NC) or 10k monitoring by the operator.
WARNING!
REMOVE POWER FROM OPERATOR
DURING WIRING AND ENSURE GATE WILL
NOT MOVE DURING PROCEDURE!
1
EMX NIR-50-325 WIRE LEGEND
(DEFAULT)
COLOR FUNCTION 1050 BOARD
DISPLAY
BROWN Power Input (+)*
BLUE Ground (-)*
PIN 20 (V+)
PIN 21 (GND)
UP
Button
OK
Button
DOWN
Button
FUNCTIONS
Button
GRAY
Normally Open
Contact (10K
Terminate): Relay output shown in energized state
(power on, aligned with reflector, no obstruction
Common (COM)
Contact
PIN 28 (EDGE)
(for Analog Open or Analog Close)
OPERATION)
WHITE PIN 29 (GND)
INDICATOR
LED (Red)
FIGURE 1-1: 1050
CONTROL BOARD
CONNECTIONS
1. Mount NIR-50-325 at desired location within
6 feet of the control box (do not mount reflector yet).
2. Wire the photoeye cable to the 1050 control board as shown at right.
(+) (-)
24VDC POWER 10K RESISTER WIRING
3. Adjust sensivity on top of unit to maximum (FIGURE 1-2). Decrease sensitivity later if there are too many false trips preventing reliable gate operation.
4. Apply power to the gate operator.
5. Program the 1050 control board as follows (FIGURE 1-1): a) Press the Functions button.
b) Press Down button eight times until “9. Adv. Settings” menu is displayed and press OK button.
c) Press Down button nine times until “UL Input” menu is displayed and press OK button.
d) Press Up/Down buttons to select “Analog” and press OK button.
e) Use Up/Down to select “Open” (open direction) or “Close” (close direction) and press OK .
DISPLAY: OR f) Press Learn button, then select slide or swing, then select light, medium, or heavy. Board will scan for sensor and then open and close gate during learn cycle. If board displays F1 error, refer to troubleshooting table. Board will not operate without at least one active entrapment sensor connected.
www.ApolloGateOpeners.com | (800) 878-7829 | [email protected]
EMX NIR-50-325 PhotoEye
INSTALLATION AND PROGRAMMING INSTRUCTIONS
6. Hold reflector 3 feet in front of photoeye lens and verify both red and yellow LEDs on photoeye
(FIGURE 1-2) light up. While moving backward to the reflector mounting location, ensure the reflector is continually aligned (red and yellow LEDs on). Move reflector up, down, left or right to keep reflector in center of the signal path.
NOTES: Signal pattern is 2 feet in diameter.
7. Verify the NIR-50-325 and reflector are in line of sight, confirm the red LED and yellow LED are ON
(indicating correct alignment), then mount reflector in ideal position.
8. Block the beam with your hand, or another object, and ensure the sensor’s yellow and red LEDs turn off.
Check the operator control board input LED (FIGURE 1-1) and verify that the UL/Edge input is properly actuated. When the beam is not blocked, the red input LED will be dimly lit and when blocked, it will be brighter.
9. Unblock the beam and the photoeye yellow and red LEDs should light at full brightness.
LED COLOR
YELLOW LED
RED LED
ON
LED INDICATION
OFF
Energized, aligned, and stable Unit off or unstable
Energized and alignment correct Beam obstructed or reflector not aligned
LENS
CAUTION!
Passing vehicles may act as a reflector and cause a false reading allowing a gate to close on a vehicle. Nice/HySecurity assumes no responsibility in these cases, and all risk falls to the installer, designer, and users of the gate system.
YELLOW
LED
RED
LED
SENSITIVITY
ADJUSTMENT
SYMPTOM
Unit stays in detect mode
No output
No detection
EMX NIR-50-325 TROUBLESHOOTING
POSSIBLE CAUSE SOLUTION
• Unit out of alignment
• Reflector covered with dirt, dust, mud, snow or water
• Water inside reflector
• No Power
• Bad connection, wires broken
• Improper wiring
• Unit not powered
• Other reflective surface causing signal return
• Verify alignment
• Clean reflector surface of contaminants
• Replace reflector
• Check power and wiring as per instructions
• Check connections
• verify wiring to control board
• Check power
• Check surrounding area for reflective surfaces
MOUNTING
BRACKETS
PHOTO EYE REFLECTOR
Contact us:
Nice | HySecurity
Kent, WA 98032
800-321-9947 hysecurity.com
FIGURE 1-2: EMX NIR-50 325 FEATURES www.ApolloGateOpeners.com | (800) 878-7829 | [email protected]