EMX NIR-50-325 PhotoEye

INSTALLATION AND PROGRAMMING INSTRUCTIONS

The NIR-50-325 retroreflective photoeye (Nice P/N MX4257) has an operating range up to 50 feet, operates over a voltage range of 12-30VDC and 24-30VAC, and is capable of normally closed

(NC) or 10k monitoring by the operator.

WARNING!

REMOVE POWER FROM OPERATOR

DURING WIRING AND ENSURE GATE WILL

NOT MOVE DURING PROCEDURE!

1

EMX NIR-50-325 WIRE LEGEND

(DEFAULT)

COLOR FUNCTION 1050 BOARD

DISPLAY

BROWN Power Input (+)*

BLUE Ground (-)*

PIN 20 (V+)

PIN 21 (GND)

UP

Button

OK

Button

DOWN

Button

FUNCTIONS

Button

GRAY

Normally Open

Contact (10K

Terminate): Relay output shown in energized state

(power on, aligned with reflector, no obstruction

Common (COM)

Contact

PIN 28 (EDGE)

(for Analog Open or Analog Close)

OPERATION)

WHITE PIN 29 (GND)

INDICATOR

LED (Red)

FIGURE 1-1: 1050

CONTROL BOARD

CONNECTIONS

1. Mount NIR-50-325 at desired location within

6 feet of the control box (do not mount reflector yet).

2. Wire the photoeye cable to the 1050 control board as shown at right.

(+) (-)

24VDC POWER 10K RESISTER WIRING

3. Adjust sensivity on top of unit to maximum (FIGURE 1-2). Decrease sensitivity later if there are too many false trips preventing reliable gate operation.

4. Apply power to the gate operator.

5. Program the 1050 control board as follows (FIGURE 1-1): a) Press the Functions button.

b) Press Down button eight times until “9. Adv. Settings” menu is displayed and press OK button.

c) Press Down button nine times until “UL Input” menu is displayed and press OK button.

d) Press Up/Down buttons to select “Analog” and press OK button.

e) Use Up/Down to select “Open” (open direction) or “Close” (close direction) and press OK .

DISPLAY: OR f) Press Learn button, then select slide or swing, then select light, medium, or heavy. Board will scan for sensor and then open and close gate during learn cycle. If board displays F1 error, refer to troubleshooting table. Board will not operate without at least one active entrapment sensor connected.

www.ApolloGateOpeners.com | (800) 878-7829 | [email protected]

EMX NIR-50-325 PhotoEye

INSTALLATION AND PROGRAMMING INSTRUCTIONS

6. Hold reflector 3 feet in front of photoeye lens and verify both red and yellow LEDs on photoeye

(FIGURE 1-2) light up. While moving backward to the reflector mounting location, ensure the reflector is continually aligned (red and yellow LEDs on). Move reflector up, down, left or right to keep reflector in center of the signal path.

NOTES: Signal pattern is 2 feet in diameter.

7. Verify the NIR-50-325 and reflector are in line of sight, confirm the red LED and yellow LED are ON

(indicating correct alignment), then mount reflector in ideal position.

8. Block the beam with your hand, or another object, and ensure the sensor’s yellow and red LEDs turn off.

Check the operator control board input LED (FIGURE 1-1) and verify that the UL/Edge input is properly actuated. When the beam is not blocked, the red input LED will be dimly lit and when blocked, it will be brighter.

9. Unblock the beam and the photoeye yellow and red LEDs should light at full brightness.

LED COLOR

YELLOW LED

RED LED

ON

LED INDICATION

OFF

Energized, aligned, and stable Unit off or unstable

Energized and alignment correct Beam obstructed or reflector not aligned

LENS

CAUTION!

Passing vehicles may act as a reflector and cause a false reading allowing a gate to close on a vehicle. Nice/HySecurity assumes no responsibility in these cases, and all risk falls to the installer, designer, and users of the gate system.

YELLOW

LED

RED

LED

SENSITIVITY

ADJUSTMENT

SYMPTOM

Unit stays in detect mode

No output

No detection

EMX NIR-50-325 TROUBLESHOOTING

POSSIBLE CAUSE SOLUTION

• Unit out of alignment

• Reflector covered with dirt, dust, mud, snow or water

• Water inside reflector

• No Power

• Bad connection, wires broken

• Improper wiring

• Unit not powered

• Other reflective surface causing signal return

• Verify alignment

• Clean reflector surface of contaminants

• Replace reflector

• Check power and wiring as per instructions

• Check connections

• verify wiring to control board

• Check power

• Check surrounding area for reflective surfaces

MOUNTING

BRACKETS

PHOTO EYE REFLECTOR

Contact us:

Nice | HySecurity

Kent, WA 98032

800-321-9947 hysecurity.com

FIGURE 1-2: EMX NIR-50 325 FEATURES www.ApolloGateOpeners.com | (800) 878-7829 | [email protected]

2

advertisement

Key Features

  • 50 ft range
  • 12-30VDC & 24-30VAC
  • Sensitivity adjustment
  • NC/10k monitoring
  • LED indicators
  • Easy installation
  • Reflective sensing
  • Gate control interface

Related manuals

Frequently Answers and Questions

How do I adjust the sensitivity of the EMX NIR-50 325 Photo Eye?
The sensitivity can be adjusted on the top of the unit. Start with maximum sensitivity and decrease it if you experience false trips.
What type of mounting brackets are used with the EMX NIR-50 325 Photo Eye?
The manual indicates that mounting brackets are available, but it doesn't specify the type.
What does the 'F1 error' on the control board indicate?
The manual advises referring to the troubleshooting table if an 'F1 error' is displayed. It suggests that there might be an issue with the entrapment sensor connection.